Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 2867 SOUTHCENTER MALL - JUJUBES - PERMITS AND PLANS
2867 SOUTHCENTER MALL ASSOCIATED PERMITS 17-F-156 08-F-271 08-S-310 SITE LOCATION Site AddressaiUteeneiY ' - `vitA Suite Numbers -2-5. Floor: CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: C' 62 1(101 C) Tenant Name:Q_ , A \c't� "Tax Property Owner's Name: V�IC k at l' ►O.. De Mailing Address: 2[�OO (SOO ,L,l IA070. UV44 98 186 City State Zip New Tenant?' - Yes ❑ - No CONTACT PERSON -if there are questions about the submittal. Name: Company Name: a Mailing Address: 1�-U E-mail Address:Gy�3 ILk r 6'ecuniu 13 Aisk St aHC041-e \AJA q8 Day Telephone: C0 • (o22 ' (c6'T) -12.4. 24 } `� rCI j G r Ci Co City State Zip UU11 �(� � Fax Number: tractor's City of T a c �y� NICET III number: Business License number: S'C PP�"/, I Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ at , ?)TAD Scope of Work (please provide detailed information): h re WiktirtV1 ffiataiad% Ort Odd/ r cel C 12) de ICe,S . J PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT . VE READ UNDER PENALTY OF PE FOR THIS PERMIT. BUILDING O �'' �,. Air AGENT: Signature: __ VAN Print Name: Plan Permit App.doc • 8/22/14 TFD FP Form 8 EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY Date: S 18 19 - Day Telephone:20(Q • (Q Z '(Q6445 QJC1, 219 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Permit No.: Date: Reviewer: Vanilla Shell 2867 Southcenter Mall 08-S310 June 11, 2008 Steve Kohler Fire Inspector/Plan Review (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 214 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. II HydrauliSummary-� `r Job Number: KS0407 Report Description: Ordinary Group II Job•..... . ... ;wti�..• ,, -. Job Number Design Engineer? KS0407 Adam Kanter Job Name State Certification/License Number Vanilla Shell 2867 , WESTESF136QF Address 1 AHJ Southcenter Mall City of Tukwila Address 2 Job Site Southcenter Mall City State , Zip Code �Drawing Name Tukwila Wa 98188 j FP-1-2867.cad System RemoteArea(s) -" Moat Demanding Sprinkler Data Occupancy 5.6 K -Factor 26.00 at 21.556 Ordinary Group II Hose Allowance At Source Density Area of Application 250.00 0.200gpm/ft2 945.00ft2 (Actual 1075.22ft2) Additional Hose Supplies Number Of Spnnklars Calculated Coverage Per Spnnkler Node Flow(opm) 10 130.00ft2 AutoPeak Results. Pressure For Remote Area(s) Adjacent To Most Remote Area Left: 77.799 Right: 77.131 Vststhe Total How Streams 250.00 I I System Flow Demand Total Water Required (Including Hose Allowance) � • /11 270.45 520.45 r '•. Maximum Pressure Unbalance In Loops `� a j k' /��.L r, 0.000 ' ''' _ Maximum Velocity Above Ground�R�r�'� 21.39 between nodes 149 and 108 �iii� M 1 .0 2 Under Ground V 1.02 between nodes 1 and 372 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 2760.61 gal Supplies / ...•, ys ;.:, cv.:ti,,. �.. . Hose Flow Static Residual @ Flow Available @ Total Demand , Required , Safety Margin Node 1 (gpm) (psi) (Psi) (gPm) (psi) (gpm) (psi) (psi) 1 250.00 140.000 i 20.000 10900.00 i 139.568 520.45 _j 82.350 57.218 c Contractor ' ✓»v -;i -?r... .� ;� l»t Contractor Number I Contact Name Contact Title KS0407 Adam Kantner Project Manager Contractor Name Plane Extension Western States Fire Protection 425.881.0100 Address 1 FAX 7102 180th Ave Ne, Suite A-105 485.736.9032 Address 2 E -mall City State Zip Coda ' Web -Site Redmond WA 1 98052 © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:23AM Page 1 IIISUrrifilie0tOtitflOWINPOW Job Number: KSO407 Report Description: Ordinary Group II Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) Sprinkler 102 26.19 26.00 5.6 21.864 Sprinkler 104 26.36 26.00 5.6 22.157 c> Sprinkler 101 26.00 26.00 5.6 21.556 Sprinkler 103 26.25 26.00 5.6 21.980 , Sprinkler 105 26.41 26.00 5.6 22.247 Sprinkler 106 26.68 26.00 5.6 22.692 Sprinkler 107 27.27 26.00 5.6 23.719 Sprinkler 109 27.56 26.00 5.6 24.216 Sprinkler 110 28.71 26.00 5.6 26.275 Sijrinkler 111 ' 29.03 26.00 5.6 26.871 b Most Demanding Sprinkler Data ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:29AM Page 2 r 111 Node Analysis Job Number: KS0407 Report Description: Ordinary Group II Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 27 17'-6 EJ2'-0) 27.696 32 17'-6 E(2'-0) 27.970 56 17'-6 P0(5'-0) 28.217 59 17'-6 P0(5'-0) 27.945 71 17'-6 P0(5'-0) 29.176 ; 74 17'-6 P0(5'-0) 28.906 90 17'-6 P0(5'-0) 31.216 93 17'-6 PO(5'-0) 30.962 117 17'-6 P0(5'-0) 34.753 108 17'-6---P0(5'-0) 34.538 148 ' 17'-6 2P0(8'-0) 47.430 149 • 17'-6 2P0(8'-0) 47.381 284 -16-1 P0(26-4) 75.192-- 5.192372 372 -14'-13/4 BFP(-4.500) 78.905 406 -16'-1 LtE(16'-0) 75.223 102 15'-0'% Spr(-21.864) 21.864 26.19 • 104 15'-0'% Spr(-22.157) 22.157 , 26.36 101 12'-0% Spr(-21.556) 21.5561 26.001 103 12'-0%. Spr(-21.980) 21.980 26.25 105 12'-0% Spr(-22.247) 22.247 26.41 10612'-0'% , Spr(-22.692) 22.692 26.68 ; 107 , 12'-0% SprE23.719) 23.719 27.27 109 12'-0% Spr(-24.216) 24.216 27.56 110 12'-0% Spr(26.275) 26.275 ' 28.71 111 12'-0'% Spr(26.871) 26.871 ; 29.03 1 1 -22'-0 S 82.350 270.45 ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:31AM Page 3 19� Hydraulic Analysis Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Length Summary Length Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Eq. Total OP Route 1 DR 1.0490 Q=26.00 9.65 C=120 0.211435 31'-8% Pf 9.036 101 12'-0% q=26.00 K=5.6 21.556 Spr(-21.556) 11'-0' Pe -2.375 56 17'-6 28.217 3E(2'-0), P0(5-0) 42'-8% Pv BL 1.6100 Q=52.36 8.25 C=120 0.095844 10'-0 Pf 0.958 56 17'-6 28.217 Pe 71 17'-6 29.176 10'-0 Pv BL 1.6100 Q=78.77 12.41 C=120 0.204040 10'-0 Pf 2.040 71 17'-6 29.176 Pe 90 17-6 31.216 10'-0' Pv BL 1.6100 Q=106.05 16.71 C=120 0.353657 10'-0 Pf 3.537 90 17'-6 31.216 1 Pe 117 17'-6 34.753 10'-0' Pv BL 1.6100 Q=134.75 21.24 C=120 0.550875 15'-0% Pf 12.677 117 17-6 34.753 8'-0Pe 148 17-6 47.430 P0(8'-0) 23'-0'% Pv CM 4.2600 Q=270.45 6.09 C=120 0.017491 405'-10 Pf 13.203 148 17'-6 47.430 177'-6 Pe 14.559 284 -16'-1 75.192 2cplg(-1.500), 2P0(26'-4), E(13''-2), 583'-4 Pv 6fE(8'-11'/2), BV(15'-9'/2), 2Ee2(5'-3'/4), CV(28'-111/2), ' GV(2'-7'h) FM 8.3290 Q=270.45 1.59 C=120 0.000668 14'-5% Pf 0.031 284 -16'-1 75.192 32'-0! Pe 0.000 406 -16'-1 75.223 fE(16'-0), LtE(16'-0) 46'-53/4 Pv FM 10.4200 Q=270.45 1.02 C=120 0.000224 28'-2% Pf 4.525 406 -16'-1 75.223 83'-0 Pe -0.842 372 -14'-1% 78.905 4LtE(16'-0), BV(19'-0), BFP(-4.00) 111.-2% Pv UG 10.4000 Q=270.45 1.02 C=140 0.000170 110'-2 Pf 0.038 372 -14'-1% 78.905 111'-7% Pe 3.407 1 -22'-0 82.350 E(35-1), 3LtE(25'-6), S 221'-9% Pv Route 2 DR 1.0490 Q=26.19 9.72 C=120 0.214229 26'-2% Pf 6.906 102 15-0% q=26.19 K=5.6 21.864 Spr(-21.864) 6'-0 Pe -1.075 27 17'-6 27.696 3E(2'-0) 32'-2Y Pv BL 1.6100 Q=26.19 4.13 C=120 0.026596 9'-4% Pf 0.249 27 17'-6 - 27.696 . Pe 59 17'-6 27.945 9'-4% Pv BL 1.6100 Q=52.44 8.26_ C=120 0.096113 10'-0 Pf 0.961 59 17-6 27.945 i Pe 74 17'-6 28.906 10'-0; Pv BL 1.6100 Q=79.12 12.47 C=120 0.205684 10'-0 Pf 2.057 74 17'-6 28.906 Pe 93 17-6 30.962 10'-0' Pv BL 1.610.0_ Q=106.67 16.81 C=120 0.35753410'-0i Pf 3.575 93 17'-6 30.962 Pe 108 17'-6 34.538 10'-0; Pv BL 1.6100 Q=135.70 21.39 C=120 0.558081 15'-0% Pf 12.843 108 17'-6 34.538 8'-0; Pe 149 17'-6 47.381 P0(5-0) 23'-0'% Pv CM 4.2600 Q=135.70 3.05 C=120 0.004883 10'-0 Pf 0.049 149 17'-6 47.381 Pe 148 17-6 47.430 10'-0' Pv • Route 3 DR 1.0490 Q=26.25 9.75 C=120 0.215281 29'-8% Pf 8.340 103 12'-0'% q=26.25 K=5.6 21.980 Spr(-21.980) 9'-0 Pe -2.375 59 17'-6 27.945 2E(2'-0), P0(5-0) 38'-8'/. Pv Route 4 DR 1.0490 Q=26.36 9.79 C=120 0.216886 25'-9 Pf 6.887 104 15'-0'% q=26.36 K=5.6 22.157 Spr(-22.157) 6'-0, Pe -1.075 32 17'-6 27.970 3E(2'-0) 31-9; Pv BL 1.6100 Q=26.36 4.15 C=120 0.026926 9'-2% Pf 0.247 32 17'-6 27.970 ' Pe 56 17'-6 28.217 9'-2% Pv - Route 5 DR 1.0490 Q=26.41 9.81 C=120 0.217696 31'-8% Pf 9.304 105 12'-0'% q=26.41 K=5.6 22.247 Spr(-22.247) 11-0 Pe -2.375 71 17'-6 29.176 3E(2'-0), P0(5'-0) 42'-8'/% Pv v Route 6 DR 1.0490 Q=26.68 9.90 C=120 0.221721 29'-8', Pf 8.589 106 12'-0% q=26.68 K=5.6 22.692 Spr(-22.692) 9'-0 Pe -2.375 74 17'-6 28.906 2E(2'-0), P0(5-0) 38'-8% Pv Route 7 ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:33AM Page 4 Hydraulic Analysis r Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K -Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length DR 1.0490 0=27.27 10.12 C=120 0.230990 31'-8%'' Pf 9.872 107 12'-0'% q=27.27 K=5.6 23.719 Spr(-23.719) 11'-0 Pe -2.375 90 17'-6 31.216 3E(2'-0), P0(5-0) 42'-8% Pv o Route 8 DR 1.0490 Q=27.56 10.23 C=120 0.235465 29'-8% Pf 9.121 109 12'-0'% q=27.56 K=5.6 24.216 Spr(-24.216) 9'-0 Pe -2.375 93 17'-6 30.962 2E(2'-0), P0(5'-0) 38'-8% Pv Route 9 DR 1.0490 Q=28.71 10.66 C=120 0.253927 31-8% Pf 10.852 110 12'-0'% q=28.71 K=5.6 26.275 Spr(-26.275) 11'-0 Pe -2.375 117 17'-6 34.753 3E(2'-0), P0(5'-0) 42'-8% Pv Route 10 DR 1.0490 Q=29.03 10.78 C=120 0.259243 29'-8% Pf 10.043 111 12'-0'% q=29.03 K=5.6 26.871 Spr(-26.871) 9'-0 Pe -2.375 108 17-6 34.538 2E(2'-0), P0(5'-0) 38'-8'/. Pv Equivalent Pipe Lengths of Valves and Fittings (C=120 only) r C Value Multiplier Value Of C Multiplying Factor 100 130 140 150 0.713 1.16 1.33 1.51 Actual Inside Diameter 14.87 = Factor Schedule 40 Steel Pipe Inside Diameter I Pipe Type Legend Units Legend Fittings Legend AO Arm -Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG UndergroundPv Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen -Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow - Eel 11W Elbow Ee2 22W Elbow f Flow Device FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap (E, ©M.E.P.CAD, Inc. inAutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:33AM Page 5 ©M.E.P.CAD, Inc. J AutoSPRINK®VR5 v5.2.6 06/05/2008 9:51:37AM Page 6 T f f Hydraulic Graph — I Job Number: KSO40 Report Description: Ordinary Group Supply at Node 1 150 Static Pressure 140.000 135 120 105 90 •N a :12- 520.45 —270.45 with hose @ 82.350 streams 75 0 N O1 a` 60 45 System demand curve 30 1 10900.00 @ 20.000 15 11LIIIIIItll 111111111 11111111 1 I I 1 1 I I 1 I 1 111111111 111111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 0 01002200 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.568 @ 520.45 System Demand 270.45 @ 82.350 System Demand (Including Hose Allowance) 520.45 @ 82.350 ©M.E.P.CAD, Inc. J AutoSPRINK®VR5 v5.2.6 06/05/2008 9:51:37AM Page 6 I 111 Flow Diagram (Top View) Job Number: KS0407 Report Description: Ordinary Group II R=. A © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:40AM Page 7 FI ALARM SYSTEM DDITION UKWILA, WASHINGTON SHEET \Uv3E� SHEET TITLE FA -01 SYSTEV I\FO�fV ATI O \ FA -02 TYPICAL WI \G A\3 IVOU\TI\G DETAILS FA -03 SYSTEM CALCULATIO\S A\D SI\GLE LI\E DIAGA V FA -04 FI �E ALA V SYSTEIV PLA\ SHEET INDEX s1. 'ii' Without Comments p As Noted in Red p Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptanc is subject to errors and omissions which do not authorize violations of adopted standards and ordinances.. The responsfbllity for the adequacy of designr!..1.-:,.-: toaliv with the designer. Additions, deletions or reNisions to tnese drawings after this data will void this acceptance aru will require a resubmittal of revised drawings ror subsequent approval. Final acceptance is subject co field test and Inspection by The Tukwila Fire Prevention Bureau. Date: ° J By: f) i TUKWILA FIRS DEPARTMENT Please call 20E-575.4407 and give this Fre Permit No. 17-F- /SS - and exact atidrzas for shut- down or restarelton approval. WISE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY E 1 1 2 2 6 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD HT -D DUAL INPUT MONITOR MODULE HTRI-D SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING FIRE ALARM s SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2" EXTN CEILING EE TENANT J -BOX (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED GREEN BLUE AS BUILT ADD OR CHANGE AS BUILT REMOVE AS BUILT NOTES TO CAD N/A N/A N/A N/A N/A N/A SYMBOLS LEGEND N/A N/A N/A N/A N/A N/A IST AVE. SO., SEATTLE, WASHINGTON Iii uJ 1-- RELEASE/REVISIONS REV. BY: 2 DESCRIPTION SHOP DRAWINGS J DATE \ d, uJ 0 2a<<a< NORDSTROM macys 2I.LD jit] lo o 3N:NhCY i.Uf l�h JNCIRSS o utl `h �C2� „N PA..FNI,:F,. tElEli EGEI JCPenney .L� CLAIRE'f Fl. v'N nRFAM 1.J 10WailliVASHMKA .FR: t> CCFTS P77".)] BEAD? 1 -'Ir_.l i.. .._..L ill . fYS (.F II L & :OUNCE SAFARI #2800 / SPACE 2867 SITE PLAN cD co CV co OU -- r - • <o Q U) Z CC 2 • JO ~� �c LL. ccI }-w< Q 2 z� U� w ccOD 0 CO w H 0) 0) (S--CALE: NOT TO SCALE DRAWN BY: D. GARCIA 6U��A FIR NUMB R2086- y ./:) �A DjCAIS20DESIGNED BY: BACKROUND PLAN PROVIDED BY: ZO4'5y-r- SHEET T. QUAALE DATE: 08/1 4/17 FA -01 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved i THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. PUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET--\ \ SAMPLING TUBE INLET—\ SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ - DEDICATED EMERGENCY FROM EXISTING MAIN FACP C CABLE C' CABLE 0 000 GRD N L 0 L I1 0 PAD -3 00 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 S 0 0 0 Q 0 0 3.6k EOL 0 0 (-) (+) (-) (+) NAC S4 NAC S3 NAC S2 NAG S1 EXISTING POWER SUPPLY WIRING DETAIL COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE o � o HARD LID CEILING HARD LID - SPEAKER SUPPORT TILE BRIDGE --4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) FROM XLS CONTROL PANEL OR if PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH „.T 0 0 GROUND -0 �t- LC) 0 HTRI—R OSTATUS LED CO 0 N.O. 0 COM 0 N.0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. MUSIC STROBE SPEAKER (+) (- CC C (+) (- STROBE C 0 (+) STROBE SPEAKER (+) (-; "1 -AC POWER SOURCE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING RELAY CONTACTS (4.OA @ 125VAC) (4.OA @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL SPEAKER STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE HFP-11 TBI 0'010® 10 NO COM NC TO FAN SHUTDOWN EOLR 470 e TO NEXT 0 ” ? ADDRESSABLE DEVICE 0 //i// 00 HTRI-R 0 NO ® COM ® NCI 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERF�TIN TEMPERATU E: +32' F (0' C TO 100' F 3S C) HUMIDITY: bb0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE ---> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE r DATA IN( )> 1. DATA IN (+) > REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINS CEILING SUPPORT 0 0 0 0 > TO NEXT ADDRESSABLE DEVICE TO NEXT DEVICE ---CADDY BAR SMOKE DETECTOR--' SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SEATTLE, WASHINGTON FAX (206) 628-4990 w RELEASE/REVISIONS co co N co Z W co OU,— go L� Z .�... QJ0 CC � d < W cry) Q CI 2 LijZ W CCOD (n I-- 0 co N 47Cm 0 MOUTHING 4CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/1 4/17 BACKROUND PLAN PROVIDED BY: _OB NUMBER:26086-1J SHEET FA -02 � i SWITCH + — INPUT LED TSM -1 e TO NEXT 0 ” ? ADDRESSABLE DEVICE 0 //i// 00 HTRI-R 0 NO ® COM ® NCI 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERF�TIN TEMPERATU E: +32' F (0' C TO 100' F 3S C) HUMIDITY: bb0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE ---> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE r DATA IN( )> 1. DATA IN (+) > REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINS CEILING SUPPORT 0 0 0 0 > TO NEXT ADDRESSABLE DEVICE TO NEXT DEVICE ---CADDY BAR SMOKE DETECTOR--' SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SEATTLE, WASHINGTON FAX (206) 628-4990 w RELEASE/REVISIONS co co N co Z W co OU,— go L� Z .�... QJ0 CC � d < W cry) Q CI 2 LijZ W CCOD (n I-- 0 co N 47Cm 0 MOUTHING 4CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/1 4/17 BACKROUND PLAN PROVIDED BY: _OB NUMBER:26086-1J SHEET FA -02 � i Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 1 0.0022 0.0022 0.0023 0.002 FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps A B C D E F G H I J K FIRE ALARM BOOSTER Project:: SAFARI Panel: • EXISTING BPS PAD -3 Date: {August 14, 2017 Module/Device POWER REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 30 30 0 30 30 0 TOTAL FIRE ALARM POWER SUPPLY 30 30 Auxiliary Device Current 0: 0 Notification Appliance Load (Max. Total / mA) 0 , 4118 zaa<a Total(A)= 30 ' Total(B)= 4148 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 30 4148 Total current ratings converted to amperes (line D x .001) 0.03 4.148 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.72 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.3455284 Add lines G and I Total Standby and Alarm AH 1.0655284 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 1.27863408 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR); 7 Notification Appliance Circuit Detail PROJECT: SAFARI Panel: ' EXISTING BPS PAD -3 REMOTE POWER SUPPLY Date: August 14, 2017 Wire Resistance 2.58 CURRENT TOTAL= 4118.00 4 DEVICES .. SET -MC -CW @15cd SET -710076W 630cd, SET -MC -CW @75cd ZR -MC -CW @15cd ZR -MC -CW @30cd 69 111 200 69 111 TOTAL mA= Total'Wire Resistance (R ) Total Device Load, Amps (I) Voltage' Drop (E) . EOL Voltage 69 111 800 138 0 1118 14. 360 21.92 ' . :1118 (WL* 2 )'*.(R1ft). (Total Cct Load) 24 - E) 1.86 1.12 2:08 21.92 SET-MC-CWw15cd SET -MC -CW @30cd `SET-MC=,CW @75cd SET -MC -CW @95cd ZR -MC -CW @15cd DEVICES MAXIMUM LOAD 111 200 264 69 TOTAL mA= Total Wire Resistance (R ) Total Device . Load, Amps (I) Voltage Drop ( E ) EOL Voltage 0 0 0. 1500, 14 24.00 (WL * 2)* (R/ft) Total ccti7Pad) (E= I * R) 24.- E) 1500 0.00 1.50 0.00 24:00 SET -MC -CW @15cd SET -MC -CW @30cd SET -MC -CW @75cd SET -MC -CW @95cdw SET -MC -W @110cd ZR -MC -CW @304 1,1 DEVICES MAXIMUM LOAD 69 111 200 264 233' 111 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 0 .' 0 0 0 0. 1500' 14 24.00 1500 (WL*2)*(R/ft) 0.00 (Total Cct Load) 1.50 (E= I * R) 0.00 24 = E) . 24.00 SYSTEM CALCULATIONS TO EXISTING SPEAKER CIRCUIT TO EXISTING SPEAKER CIRCUIT TO EXISTING REMOTE BOOSTER POWER SUPPLY TO EXISTING DATA LOOP V S3-1 S3-2 S3-3 S,V V S,V y S,V y S,V y S,V S3-4 S3-5 S3-6 S3-7 S3-8 15cd 15cd 15cd 75cd 75cd 75cd 75cd 30cd (TENANT J -BOX) HT -R D b 3D D, I -c=p HT -R 2I TSM EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Iftm lfte 1743 IST AVE. SO., SEATTLE, WASHING T Oft FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 08/14/17 zaa<a ---- Cr 0 0 w z co co LU Z W co 00'- z o co z L .._.. Q _II_ �0 °CW� z LL c _ ) < "' Q Cl') (1) 2 w Z� 0 Lu CC o c0o 0 0 LU H- C,l`) CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/14/17 BACKROUND PLAN PROVIDED BY: \0B NUMBER:26086-12 SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET v1ALL_ CONCOUISEI CI ECK IN 1 ,' / S375 .� — — -75cd s.v mei S3-6 75cd S,V --o o-- S,V S3-4 75cd Eg S,V--o 00Nil C_. / S3-1 0 M I T-, s S3-3 15cd LA' AR EA troll I— HT-R REG j [4D I HT -R TSM rFiziS3-7 75cd S,V EOL S3 S3-8 30cd PAI- I Y P00k'l v—o—CD o—D 00 Ci) mo D D McX—n mu, --II� c 0Z 03Z o0 530 of,) 0 FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved GUARDIAN SECURITI 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 N X TEL. (206) 622-6545 GO z 0 GO w Ic UJ U) UJ J W CC REV. BY: 0 m 0 z 0 +z v w 0 SHOP DRAWINGS DATE 08/14/17 Cid co N Z W ccoo O U 0_o 0 C/)Z <JH d 4. F - LL >WCn < < %J W =J W 15 CC O D L-. um -- 0 co N �CALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/ 14/ 17 BACKROUND PLAN PROVIDED BY: JOB NUMBER:26086-1} SHEET FA -04 � i WESTFIELD SUITE 2867 FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \UM3ESHEET TITLE FA -01 SYSTEM INFORNATIO\ FA -02 TYPICAL DETAILS - WRI\G A\D \AOU\TI\G FA -03 FRE ALARM SYSTEM FLOOR PLAN. FA -04 SYSTEM CALCULATIO\S (GE\EAL), RISE, SITE PLA\ WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N . SYMBOL. DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIAT❑R TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9_ FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL. BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE. CABLE IS INSTALLED QUANTITY 1 2 2 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACK BOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP ® INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD I - < LINEAR BEAM I SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD A SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE ®D DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) gL C Dc FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM STROBE (CEILING MOUNT) SET -MC -CW SIEMENS SET -MC -W -SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 4S DEEP BOX W/ 1-1/2" EXT. CEILING 80" A.F.F. TO BOTTOM SET -HMC -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM © STROBE (WALL MOUNT) Y c ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING B WP MR FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) MULTI -VOLTAGE CONTROL RELAY SET -W SIEMENS SET -S17 -WP SIEMENS MR -201/C AIR PRODUCTS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. ... IN FIEL[ U -' y� , '' Without Comments IN FI ELI)t A.F.F. ABOVE FINISHED FLOOR N/A A / i As Notig4 Ai Red 0 Per e Attached Letter N/A F.B4O, FURNISHED BY OTHERS N/A A1ese plans have beetslc siewed by TheTukwila,F,ife Prevention Bureau for conformance with current city is to errors and N/A ANOT PPLICABLE N/A staiidardb. AccepUnce r.uhieot N &nissicns which do nolt ihorize violations of ado ted standards and ormnances. The responsibility for the the designer. aaaaa U.O.N. UNLESS OTHERWISE NOTED N/A adequacy of de.iyr i i bs toteCy with N Additions, deletions orroitsians to these drawir gs gtter this date will void this,aCCeptance and will require a WP WEATHERPROOF DEVICEFinal N/A resubmittal of revised drawings fai bubDequent approval. N A N/A N/A acceptance is subject to field test and inspection by ACO FII RED AS BUILTThe ADD OR CHANGE N/A Tukwila Fire Prevention bureau. N A N/A N/A By: 0700 Cert t( -.._. _ .... jDateA6r ., ,. mml GREEN REMOVE BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A 'TUKWILA FIRE DEPARTMi Tease call: 575.4407, ,and give this job ;end exact address for shut+ !Sown or restoration approvaai el) MOM Civ/05 NOTICE z IU ca z cc z r4) ON 1743 IST AVE. ON ON ao N .0 0 0 CV X• U - .o (V N 0 0 CV J UJ I - RELEASE/REVISIONS Do w EGH I DESCRIPTION SHOP DRAWINGS DATE 05/20/2008 9 aaaaa co 00 N arc; Lu22z I-Woc0 Cn 2 w= a �_� Q f-§ W w� . LL A vJ co1-7 (Nol D I.LI IF- mpleted, signed, T la 'e Department Pre -'test ificate must be presented the Inspector prior to nencement of Acceptance Testing of any Fire A arm and Detection Systems. Failure of test will result in a Re -inspection Fee and ination of the testing. PAM JUL - 9 2008# 171,66V7 (1) SCALE: 1/8" =1 ' DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE:05/20/2008 BACKROUND PLAN PROVIDED BY: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved \OB NUMBER: SHEET FA 01 , -,v,r7 S L a8z THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE A_ A STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR i+ PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) _L O SUPERVISED SWITCH ------ -' GROUND -4D 0 HTRI—R OSTATUS LED DUCT DETECTOR L❑CATI❑N N 0 0 0 N.O. COM N.0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 11 VOLTAGE MAX. - CURRENT MAX -- CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING=---\ TUBE INLET SAMPLING—\ TUBE \ \ AT LEAST SIX DUCT WIDTHS FROM BEND 1 TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE {(+;- FROM XLS CONTROL PANEL OR .[(+) PREVIOUS ADDRESSABLE DEVICE () END OF LINE DEVICE (3.6K 1/4W) RELAY CONTACTS <4.0A @ 125VAC) 0.0A @ 30VDC) 27 VDC 3.5 mA DURING -POLLING 10 OHMS 200 FT. (18 AVG) 0,02uF 0,04uF 14 AWG 18 AWG NOTE 21 ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTION, 0 k I TB1 soman 23456 HCP TB2 654321 0 N 7 SUPERVISED SWITCH i GROUND 0 0 HTRI—D OSTATUS LED CO 0 0 NOT USED 0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 nCND N AC I U 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1— 1 2+2— 2 NC C NO + — + — + — + — +.Ise — mmm��omm��m������me 24K n TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END OF LINE DEVICE 3.6K 1/4W) \SUPERVISED 1 SWITCH NAC -4 NAC -3 NAC -2 NAC -1 1 FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP.!. 0 0 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS EOL 0 INPU (+ t-) )P P1 IP 61 TSM -1 C 0 172:3:4-5- C C -1? _3 4.5, CQC e TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE 0 E FROM REMOTE POWER SUPPLY C'S' CABLE) FROM FACP <V❑ICE CIRCUIT) CV' CABLE) (+) (-) STROBE SPEAKER ('2 EARTH GROUND -->(+)TO NEXT DEVICE OR } .(-) STOP IF LAST DEVICE (STR❑BE) (STR❑BE) SPEAKER (+) (-) SPEAKER1STROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80" A.F.F. R 0 4S DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERtT1N TEMPERATU E: +32"F (0' C) TO 100" F 38' C) HUMIDITY: 0-9333333% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) >- DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE DB -11 STANDARD SMOKE DETECTOR BASE TO NEXT DEVICE -E- ( ) DATA OUT > (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING HARD LID ----•\ -----SPEAKER SUPPORT Ti — BRIDGE --- 4" SQUARE DEEP BOX .---- WITH 1-1/2" EXTENSION N. CEILING MOUNTED N SPEAKER/STROBE \. CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTI❑N BOX MOUNTED ON \\ CEILING FLEX \ JUNCTII MOUNTED A CEILING SI / / / / / / N BOX ---- iAINST PPORT 0 0 0 0 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING DO N.0 INSTA_L ADDRESSA LE IN DEVICES J INTI PREPROGRAM\ED W DEVICES ADDRESS. ITIATING TH z ©Q rn co a` 0 Fz (n w J t --- a LU O U) ra O a' a' co N X U- RELEASE/REVISIONS z DESCRIPTION SHOP DRAWINGS LLl Q 0 CO 0 0 N \ 0 N u7 0 O z C CD co co N —'c; W2�Z I_wcE0 w= W Q�' rrI- L 1.6.1 vJ CoD W E— SCALE: 1/8" =1 ' z 0 DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE:05/20/2008 BACKROUND PLAN PROVIDED BY: .OB NUMBER: SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ��—O2 2S,2V NORTH SUITE 2861 WESTFIELD SOUTHCENTER MALL SCALE 118":1' -i FLAG N ES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,CSEE SIEMENS INSTALLATI❑N SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLATOR FIRE SUPPRESION SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. DO \ ADD DEVICES J PRER.RO GRA DEVICES AD OT 0 \ S ALO ESSABLE MOT \TIL D AGING D WO ESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved -4 o rO O' 00 \ 00 N O `o O C) z N = v W F- F- LU - FW CD • Lo Cl).'? N LLj N a U) N —W RELEASE/REVISIONS REV. BY: I 0 W DESCRIPTION SHOP DRAWINGS DATE 05/20/20081 9aaa<a N. co co C 7.11111-5 <0) W 2 2Z - WHO D ��� .1I e-% 5 _< - ¢> C '1(0� N D w H SCALE: 1/8"=1' DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE:05/20/2008 BACKROUND PLAN PROVIDED BY: JOB NUMBER: SHEET FA -03} NORTH SUITE 2867 WESTFIELD SOUTHCENTER MALL SCALE 1132'=1' 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 115 C 115 C 75 C 15 15 EOL -S1 EX D,I 2I SYSTEM CALCULATIONS BATTERY SIZING CALCULATION 2867 2867 Wire Resistance 1.62 FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations Date: June 2, 2008 CURRENT TOTAL= 939 CIRCUIT: S1 Current Load: QTY Device Type Standby: Alarm: Wire Size Current Load: Voltage at EOL Circuit Total Standby: Alarm: 0 SET -MC @15CD 64 0 ■Total Wire Resistance ( R 0.86 0 @30CD 98 0 Device Type Qty Amps Total Amps Total Device Type Qty Amps ■ Total Amps Total HFP-11 0.0022 0.0022 0.0023 . (Total Cct Load) 2 : 636 AD2-P Voltage Drop (E) .,1 0.0635 0.0635 0.064 0.064 Main System Board 1 0.03 (E= I * R) 0.03 0.030 0.030 318 HTR -R 2 0.009600 0.0096 .0.021 0.042 19.59 SET -MC @15CD 445 0 0.064 (20.4 - E) HTRI-D 2 Z-MC@15CD 0.001600 128 0.0035 SET -MC @30CD 0 Z-MC@3OCD 0.098 0 ICP -B6 0.005 0 SET-MC-CW@11OCD SET -MC @75CD 0 1 0.175 0.175 DEVICES= 5 TOTAL mA= 939 12 265 19.5937746 • SET -MC @110CD 0.233 ION Notification Appliance Circuit Detail SET-HMC-C@115CD 2 PROJECT: 0.318 0.636 2867 Wire Resistance 2.58' . ` ., SET HMC-C@135CD Date: June 2, 2008 CURRENT TOTAL= 0.318 SPEAKER CIRCUIT 0.0731 Amps 0.106 Amps SET HMC-C@185CD U 0.445 Total- VVire Length Voltage at EOL. _ , ZR -MC @15CD 3 2 - 0.064 0.128 Standby Current Load: Total Wire Resistance (R) 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @3OCD (WL*2)*(R/ft) 0.098 0 ■Total HCP 0.01 0 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0 0 0.03 Amps 0.969 Amps • 0 0 (E= l * R) 0 0 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours , 0 0 0 0 Alarm Current Load: DEVICES= swimmii 0.969 Amps 5.4 For 5 Minutes= 0.081 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 1.002 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 1.002 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved Gotg CC CD 0' CO N 0 0 N X U- TEL. (206) 622-6545 RELEASE/REVISIONS m LU cr 0 w DESCRIPTION 0 uJ F- CO 0 0 N 0 N U) O << r J 0 W c co CC CO co ., N �� j W <Z ®C �- w cc 0 CC ZZ O CC e Q 0 � W Q �S w (cc � F- 0 Cf� N= W I- V J 0 LU C/) / SCALE: SEE SHEET DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 BACKROUND PLAN PROVIDED BY: \0B NUMBER: J SHEET FA -04 j 2867 Wire Resistance 1.62 Date: June 2, 2008 CURRENT TOTAL= 939 CIRCUIT: S1 QTY Device Type Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 0 SET -MC @15CD 64 0 ■Total Wire Resistance ( R 0.86 0 @30CD 98 0 (R/ft) 1 ■ Total Device Load, Amps (I) 0.94 0 . (Total Cct Load) 2 : 636 Voltage Drop (E) 0.81 0 445 (E= I * R) 0 0 SET -HMC @135CD 318 0 U EOL Voltage 19.59 SET -HMC @185CD 445 0 (20.4 - E) 2 Z-MC@15CD 64 128 0 Z-MC@3OCD 98 0 0 SET-MC-CW@11OCD 233 0 DEVICES= 5 TOTAL mA= 939 12 265 19.5937746 • ION Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL 2867 Wire Resistance 2.58' . ` ., Date: June 2, 2008 CURRENT TOTAL= 5.4 SPEAKER CIRCUIT U QTYAlarm Total- VVire Length Voltage at EOL. _ , 3 70.7V 1/81.8 - Total Wire Resistance (R) 2.92 0 (WL*2)*(R/ft) 0 ■Total Device Load, Amps (I) 0.01 0 0 (Total Cct Load} 0 0 Voltage Drop (E) 0.02 • 0 0 (E= l * R) 0 0 EOL Voltage 20.38 • 0 a 0 , 0 0 0 0 DEVICES= swimmii 3 TOTAL m A= 5.4 14 565 20.38425684 RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved Gotg CC CD 0' CO N 0 0 N X U- TEL. (206) 622-6545 RELEASE/REVISIONS m LU cr 0 w DESCRIPTION 0 uJ F- CO 0 0 N 0 N U) O << r J 0 W c co CC CO co ., N �� j W <Z ®C �- w cc 0 CC ZZ O CC e Q 0 � W Q �S w (cc � F- 0 Cf� N= W I- V J 0 LU C/) / SCALE: SEE SHEET DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 BACKROUND PLAN PROVIDED BY: \0B NUMBER: J SHEET FA -04 j MEM General Notes -too t's'i ./xo _is 4 tea - 3 -1 .t rr (le WORM. tttt itmtt1 1 z L• - dill 1 • - �-- A! milw . VLC1NITh MAP SCALE: NTS u ite#286-) 2867 SHELL SPACE 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain.. Western' States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. ZONE T9 EAST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE 27 Ordinary Group 11.0.200gpm/ft2 for 945.00ft2 030.53 i t4..1./ - '< % � p�FFY/ / 5 / .. ro , •/ r' // j w! �` % i /� . i v�Lr i 26� 15'.0" A.F.F 1NNEN= ■Y® iuuiii 11111111111 :11111111111111011111M1111111111 1w112:.9.1•��0 3111 ��� F I RIIIIIi� 1 mss'-ai%i� F��i 1111 1En aliiil•riNiU ra" - W' !liaidii 12'-0" A.F.F gele CM BM 27 ERIE SPRINKLERS_Y_3TENL EXISTING MAIN ZONE T9 8'-0" A.F.F 1 3 5 7 9 I TYPICAL FLEXABLE SPRINKLER CONNECTION: FLEXHEAD PIPE NIPPLE MOUNTING BRACKET ...tea .... SPRINKLER BRANCHLINE FLEXABLE CONNECTING' HOSE IN STANDARD LENGTHS # REDUCING FITTING SUSPENDED T -BAR GRID CEILING TILE SPRINKLER HEAD FLEXHEAD DETAIL NOT TO SCALE FIG 009 �r SNWELSWAY —� BRACE FITTING BRACE PIPE FIG. 1000 �"FASTCLAMP• SWAY BRACE ATTACI@AENT 3/0' KWIK BOLT r (2I W" EMBED LENGTH) LINE PIPE LATERAL LINE RESTRAINTS WIN -THREADED BRACE PIPE Remote Area 2867 SHELL SPACE CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 occuPANcv CLASS ORD HAZARD 1I MAX. COVERAGE per HEAD 130 FN DENSITY .20 GPM / Ft' for 945.0 Ft' I SPRINKLER Reliable F1 FR Semi-Rec ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 270.45 GPM © 78.90 PSI ' At time of Design 12'- 0" CI.G. = 37.00% AREA REDUCTION FIG. 4A PIPE CLAMP FOR SWAY BRACE 3/0` KWIK BOLT (2 1/4' EMBED LENGTH) FIG. 009 NO•THREAD SWIVEL SWAY BRACE ATTACHMENT Jl LATERAL BRANCHLINE RESTRAINT SP�fl NON•THREADED BRACE PIPE LATERAL BRANCIELINE RESTRAINT r 1 NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III / / HILTI KNI& Bolt 11 / ` Drilled Anchor -Et i( Cut Rod Lgth' Rounded to Nearest Inch Rod Coupling —� q. Swivel Ring Con Constru Bottom o Center L Note on Note on Plan: Hanger Number and 'A Dimension % // i nese plans have been reviewed by The Tukwila Fire artfIention Bureau for conformance with current city g'iandards. Aa.ceptance is subject to errors and omissions wh ch do not authorize violations of adopted starxlaras and ordinances. The responsibility for the on rete o quacy of d esig. n rests totally with the designer. dditions, del :tions or revisions to these drawings atter this date will vNoid this.acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire, Prevention Bureau / Without Comments As Noted In Red Per The Attached Letter HANGER DET Date: covoe By: 15-X0 k._ NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE I UI WILA FIRE. DEF'AR7iV�,U'd lease call: 575-4407 and give this job and exact address for shuts down or restoration approval, NOTICE Weld stamps must be inspected before pipe is hung.. Do not paint piping prior to hydrostatic test approval. • (0 co N CO lY w z Adam Kantner SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE. 0 R3615 32 5.6 Pendent 1/2.I Chrome 155°F F1FR Semi- Rec APPROVAL: City of Tukwila HYDRAULIC REFERENCE POINT R5415 10 5.6 Pendent White 155°F G4A Concealed CONT. NO.: KS0407 Total = 42 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 06/05/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 tic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY -OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/DECATUR/DENVER/DULUTH/HOUSTON/KANSAS CITY LAS VEGAS/MINNEAPOLIS/PHOENIX/PORTLAND /RAPID CITY/ ST. PAUL/SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 Vanilla Shell 2867 Southcenter Mall Tukwila ,Wa 98188 FRIE SPRINKLER SYSTEM 000 v SIiEL r FP -1 OF 1 �Lc 0 111- '-- 11111 /1 171-1:177;-, 1 a Vii► ^- ; 1��rrL �`. t<.{ r M �T-- u r. 11 1 �� General Notes l VICINITY MAP (Suite#2867) SCALE: NTS / x, 2867 SHELL SPACE 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. ZONE T9 EAST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE 27 Ordinary Group II.0.200gpm/ft2 for 945.00ft2 s• FRIE SPRINKLER SYSTEM 1/8"=1-0' 15'-0" A.F.F F 12'-0" A.F.F EXISTING MAIN ZONE T9 8' 0" A.F.F 28 TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD • MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING �%hW4�!N!T SUSPENDED T -BAR GRID �M��M�MY✓.nM.tl:wwtai>MyFria%•r..jW+:t.=M1'1"i.YM`>h l'.P(J�.+rArnt.. 11'...M.f.0,1PWr.r...,ANxis'yFP^4.:**1n+9M1,4101.,M,O,,109 404..,At@p•AIJd05RMW4WN SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE 3/9' KWIK BOLT - -• (21W EMBED LENGTH) FIG. 909 SWIVEL SWAY BRACE FITTING FIG. 1000 "FAST CLAMP' SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE Remote Area 2867 SHELL SPACE CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM / Ft` for 945.0 Ft' SPRINKLER Reliable Fl FR Semi-Rec ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 270.45 GPM © 78.90 PSI ' At time of Design 12'- 0" CLG. = 37.00% AREA REDUCTION FIG. 4A PIPE CLAMP FOR SWAY BRACE LATERAL BRANCHLINE RESTRAINT 3/9' KWIK BOLT (2 1W EMBED LENGTH) FIG. 909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT BRACE PIPE SA.._ to NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE / HILTI Kw& Bolt II Drilled An hor \ / Hanger No. 07C HILTI Kwik Bolt III Cut Rod Lgth Rounded to Nearest Inch Rod CoAll Thuplingread �` Concrete f Construction RodII -"Mi •:‹ 1111111111 Swivel Ring Pipe Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE Vanilla Shells 2867 CE W z 0 Adam Kantner Swinerton Builders CE 0 I- .z O U SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE HYDRAULIC REFERENCE POINT HANGER SYMBOL R3615 32 5.6 Pendent %' Chrome 155°F Fl FR Semi- Rec APPROVAL: City of Tukwila R5415 10 5.6 Pendent White 155°F G4A Concealed CONT. NO.: KS0407 BRANCHLINE RESTRAINT Total = 42 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 06/19/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN /DALLAS, DECATUR /DENVER /DULUTH /HOUSTON /KANSAS CITY LAS VEGAS /MINNEAPOLIS /PHOENIX /PORTLAND, RAPID CITY/ ST -PAUL/ SALT TAKE CITY/ SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 Vanilla Shells 2867 Southcenter Mall Tukwila ,Wa 98188 FRIE SPRINKLER SYSTEM SI -IEE T FP OF 1 1 (. 0 : t"1 `� 0 ,i..7 7 0 JQ i//,/i/, 27 ®j / `' /% , .// /; %//. / / / ' (t�' _ / , ' / 4•;..--.i'Li • S' •/ / � r/ ,/ "i / •• /. % •l/ ' / .' / ' /" ,// /' , , V.- , 4 Q 1 I N' . /'' i ,' N `' 71 / 74 C4 ' ' /' /%, %, ' / %f / /% , ; // / / / - / ./ ,/, i / , Qi _/ /.' to. / _ / i / / •'r /%• 1 N1 (Vv 1 l �X. , l' / ' /,_4,•.\ .ly / _ _ ` i / i i,�, /,�`// J' ,r/ of/r, !, /, / / • r,/to'/ , / ,'/// / / • • / + ' / / • • .r• 1/ % �•; ; `/. • / , /' / Ne �t5 t _ . oil ij ` ' tL' •` ; t; t 17 .i• : / / , i 5-9/:-- --- • fl IA I- 1'/' / i,, 9 'ti, !/' /L Q %' '/, /// �; /,•/ / 1/" r/:/j/,%/ /%/ / / • r/ '/// /`• //�,// /. — _i_T,, _ i IT ..._.,.[,N, ..t. - i -p Crj o t ,a oozy I ka _ t 44 1 ,A 5'-9%: 0 :11•1,1) %: «. 0 2'-0% e- 0 0 o e oa 6 PPPP , Ism 1631116311I� MS N» o• ::.? IV N r I A 'I + � NZ e01 :-.I WM `I ® . : ° , 14 zoa ? S taa 'S' 1 eat emm 149 emal - Y s I I s 'S ' ' .' um sib SO i ,4 (<. d`' 1 Ott° ok• 1 11 0. . 5-9% l'- a % 1 .. , 2'-0%: ' i to.- I O�CO' 1 �__�_L_ = 0'9® 0 0 0 O" 0 Och`C,/ ,� r y } 0�,� ...tom I 1._ 4e; -,c jj '®-_ic-ko "((\. 0d'`& 1 t' 1 OqV __ ci' 2-8'/+M1b 1.4 .O, FRIE SPRINKLER SYSTEM 1/8"=1-0' 15'-0" A.F.F F 12'-0" A.F.F EXISTING MAIN ZONE T9 8' 0" A.F.F 28 TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD • MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING �%hW4�!N!T SUSPENDED T -BAR GRID �M��M�MY✓.nM.tl:wwtai>MyFria%•r..jW+:t.=M1'1"i.YM`>h l'.P(J�.+rArnt.. 11'...M.f.0,1PWr.r...,ANxis'yFP^4.:**1n+9M1,4101.,M,O,,109 404..,At@p•AIJd05RMW4WN SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE 3/9' KWIK BOLT - -• (21W EMBED LENGTH) FIG. 909 SWIVEL SWAY BRACE FITTING FIG. 1000 "FAST CLAMP' SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE Remote Area 2867 SHELL SPACE CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM / Ft` for 945.0 Ft' SPRINKLER Reliable Fl FR Semi-Rec ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 270.45 GPM © 78.90 PSI ' At time of Design 12'- 0" CLG. = 37.00% AREA REDUCTION FIG. 4A PIPE CLAMP FOR SWAY BRACE LATERAL BRANCHLINE RESTRAINT 3/9' KWIK BOLT (2 1W EMBED LENGTH) FIG. 909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT BRACE PIPE SA.._ to NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE / HILTI Kw& Bolt II Drilled An hor \ / Hanger No. 07C HILTI Kwik Bolt III Cut Rod Lgth Rounded to Nearest Inch Rod CoAll Thuplingread �` Concrete f Construction RodII -"Mi •:‹ 1111111111 Swivel Ring Pipe Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE Vanilla Shells 2867 CE W z 0 Adam Kantner Swinerton Builders CE 0 I- .z O U SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE HYDRAULIC REFERENCE POINT HANGER SYMBOL R3615 32 5.6 Pendent %' Chrome 155°F Fl FR Semi- Rec APPROVAL: City of Tukwila R5415 10 5.6 Pendent White 155°F G4A Concealed CONT. NO.: KS0407 BRANCHLINE RESTRAINT Total = 42 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 06/19/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN /DALLAS, DECATUR /DENVER /DULUTH /HOUSTON /KANSAS CITY LAS VEGAS /MINNEAPOLIS /PHOENIX /PORTLAND, RAPID CITY/ ST -PAUL/ SALT TAKE CITY/ SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 Vanilla Shells 2867 Southcenter Mall Tukwila ,Wa 98188 FRIE SPRINKLER SYSTEM SI -IEE T FP OF 1 1 2867 SOUTHCENTER MALL ASSOCIATED PERMITS 17-F-156 08-F-271 08-S-310 SITE LOCATION Site AddressaiUteeneiY ' - `vitA Suite Numbers -2-5. Floor: CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: C' 62 1(101 C) Tenant Name:Q_ , A \c't� "Tax Property Owner's Name: V�IC k at l' ►O.. De Mailing Address: 2[�OO (SOO ,L,l IA070. UV44 98 186 City State Zip New Tenant?' - Yes ❑ - No CONTACT PERSON -if there are questions about the submittal. Name: Company Name: a Mailing Address: 1�-U E-mail Address:Gy�3 ILk r 6'ecuniu 13 Aisk St aHC041-e \AJA q8 Day Telephone: C0 • (o22 ' (c6'T) -12.4. 24 } `� rCI j G r Ci Co City State Zip UU11 �(� � Fax Number: tractor's City of T a c �y� NICET III number: Business License number: S'C PP�"/, I Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ at , ?)TAD Scope of Work (please provide detailed information): h re WiktirtV1 ffiataiad% Ort Odd/ r cel C 12) de ICe,S . J PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT . VE READ UNDER PENALTY OF PE FOR THIS PERMIT. BUILDING O �'' �,. Air AGENT: Signature: __ VAN Print Name: Plan Permit App.doc • 8/22/14 TFD FP Form 8 EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY Date: S 18 19 - Day Telephone:20(Q • (Q Z '(Q6445 QJC1, 219 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Permit No.: Date: Reviewer: Vanilla Shell 2867 Southcenter Mall 08-S310 June 11, 2008 Steve Kohler Fire Inspector/Plan Review (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 214 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. II HydrauliSummary-� `r Job Number: KS0407 Report Description: Ordinary Group II Job•..... . ... ;wti�..• ,, -. Job Number Design Engineer? KS0407 Adam Kanter Job Name State Certification/License Number Vanilla Shell 2867 , WESTESF136QF Address 1 AHJ Southcenter Mall City of Tukwila Address 2 Job Site Southcenter Mall City State , Zip Code �Drawing Name Tukwila Wa 98188 j FP-1-2867.cad System RemoteArea(s) -" Moat Demanding Sprinkler Data Occupancy 5.6 K -Factor 26.00 at 21.556 Ordinary Group II Hose Allowance At Source Density Area of Application 250.00 0.200gpm/ft2 945.00ft2 (Actual 1075.22ft2) Additional Hose Supplies Number Of Spnnklars Calculated Coverage Per Spnnkler Node Flow(opm) 10 130.00ft2 AutoPeak Results. Pressure For Remote Area(s) Adjacent To Most Remote Area Left: 77.799 Right: 77.131 Vststhe Total How Streams 250.00 I I System Flow Demand Total Water Required (Including Hose Allowance) � • /11 270.45 520.45 r '•. Maximum Pressure Unbalance In Loops `� a j k' /��.L r, 0.000 ' ''' _ Maximum Velocity Above Ground�R�r�'� 21.39 between nodes 149 and 108 �iii� M 1 .0 2 Under Ground V 1.02 between nodes 1 and 372 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 2760.61 gal Supplies / ...•, ys ;.:, cv.:ti,,. �.. . Hose Flow Static Residual @ Flow Available @ Total Demand , Required , Safety Margin Node 1 (gpm) (psi) (Psi) (gPm) (psi) (gpm) (psi) (psi) 1 250.00 140.000 i 20.000 10900.00 i 139.568 520.45 _j 82.350 57.218 c Contractor ' ✓»v -;i -?r... .� ;� l»t Contractor Number I Contact Name Contact Title KS0407 Adam Kantner Project Manager Contractor Name Plane Extension Western States Fire Protection 425.881.0100 Address 1 FAX 7102 180th Ave Ne, Suite A-105 485.736.9032 Address 2 E -mall City State Zip Coda ' Web -Site Redmond WA 1 98052 © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:23AM Page 1 IIISUrrifilie0tOtitflOWINPOW Job Number: KSO407 Report Description: Ordinary Group II Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) Sprinkler 102 26.19 26.00 5.6 21.864 Sprinkler 104 26.36 26.00 5.6 22.157 c> Sprinkler 101 26.00 26.00 5.6 21.556 Sprinkler 103 26.25 26.00 5.6 21.980 , Sprinkler 105 26.41 26.00 5.6 22.247 Sprinkler 106 26.68 26.00 5.6 22.692 Sprinkler 107 27.27 26.00 5.6 23.719 Sprinkler 109 27.56 26.00 5.6 24.216 Sprinkler 110 28.71 26.00 5.6 26.275 Sijrinkler 111 ' 29.03 26.00 5.6 26.871 b Most Demanding Sprinkler Data ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:29AM Page 2 r 111 Node Analysis Job Number: KS0407 Report Description: Ordinary Group II Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 27 17'-6 EJ2'-0) 27.696 32 17'-6 E(2'-0) 27.970 56 17'-6 P0(5'-0) 28.217 59 17'-6 P0(5'-0) 27.945 71 17'-6 P0(5'-0) 29.176 ; 74 17'-6 P0(5'-0) 28.906 90 17'-6 P0(5'-0) 31.216 93 17'-6 PO(5'-0) 30.962 117 17'-6 P0(5'-0) 34.753 108 17'-6---P0(5'-0) 34.538 148 ' 17'-6 2P0(8'-0) 47.430 149 • 17'-6 2P0(8'-0) 47.381 284 -16-1 P0(26-4) 75.192-- 5.192372 372 -14'-13/4 BFP(-4.500) 78.905 406 -16'-1 LtE(16'-0) 75.223 102 15'-0'% Spr(-21.864) 21.864 26.19 • 104 15'-0'% Spr(-22.157) 22.157 , 26.36 101 12'-0% Spr(-21.556) 21.5561 26.001 103 12'-0%. Spr(-21.980) 21.980 26.25 105 12'-0% Spr(-22.247) 22.247 26.41 10612'-0'% , Spr(-22.692) 22.692 26.68 ; 107 , 12'-0% SprE23.719) 23.719 27.27 109 12'-0% Spr(-24.216) 24.216 27.56 110 12'-0% Spr(26.275) 26.275 ' 28.71 111 12'-0'% Spr(26.871) 26.871 ; 29.03 1 1 -22'-0 S 82.350 270.45 ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:31AM Page 3 19� Hydraulic Analysis Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Length Summary Length Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Eq. Total OP Route 1 DR 1.0490 Q=26.00 9.65 C=120 0.211435 31'-8% Pf 9.036 101 12'-0% q=26.00 K=5.6 21.556 Spr(-21.556) 11'-0' Pe -2.375 56 17'-6 28.217 3E(2'-0), P0(5-0) 42'-8% Pv BL 1.6100 Q=52.36 8.25 C=120 0.095844 10'-0 Pf 0.958 56 17'-6 28.217 Pe 71 17'-6 29.176 10'-0 Pv BL 1.6100 Q=78.77 12.41 C=120 0.204040 10'-0 Pf 2.040 71 17'-6 29.176 Pe 90 17-6 31.216 10'-0' Pv BL 1.6100 Q=106.05 16.71 C=120 0.353657 10'-0 Pf 3.537 90 17'-6 31.216 1 Pe 117 17'-6 34.753 10'-0' Pv BL 1.6100 Q=134.75 21.24 C=120 0.550875 15'-0% Pf 12.677 117 17-6 34.753 8'-0Pe 148 17-6 47.430 P0(8'-0) 23'-0'% Pv CM 4.2600 Q=270.45 6.09 C=120 0.017491 405'-10 Pf 13.203 148 17'-6 47.430 177'-6 Pe 14.559 284 -16'-1 75.192 2cplg(-1.500), 2P0(26'-4), E(13''-2), 583'-4 Pv 6fE(8'-11'/2), BV(15'-9'/2), 2Ee2(5'-3'/4), CV(28'-111/2), ' GV(2'-7'h) FM 8.3290 Q=270.45 1.59 C=120 0.000668 14'-5% Pf 0.031 284 -16'-1 75.192 32'-0! Pe 0.000 406 -16'-1 75.223 fE(16'-0), LtE(16'-0) 46'-53/4 Pv FM 10.4200 Q=270.45 1.02 C=120 0.000224 28'-2% Pf 4.525 406 -16'-1 75.223 83'-0 Pe -0.842 372 -14'-1% 78.905 4LtE(16'-0), BV(19'-0), BFP(-4.00) 111.-2% Pv UG 10.4000 Q=270.45 1.02 C=140 0.000170 110'-2 Pf 0.038 372 -14'-1% 78.905 111'-7% Pe 3.407 1 -22'-0 82.350 E(35-1), 3LtE(25'-6), S 221'-9% Pv Route 2 DR 1.0490 Q=26.19 9.72 C=120 0.214229 26'-2% Pf 6.906 102 15-0% q=26.19 K=5.6 21.864 Spr(-21.864) 6'-0 Pe -1.075 27 17'-6 27.696 3E(2'-0) 32'-2Y Pv BL 1.6100 Q=26.19 4.13 C=120 0.026596 9'-4% Pf 0.249 27 17'-6 - 27.696 . Pe 59 17'-6 27.945 9'-4% Pv BL 1.6100 Q=52.44 8.26_ C=120 0.096113 10'-0 Pf 0.961 59 17-6 27.945 i Pe 74 17'-6 28.906 10'-0; Pv BL 1.6100 Q=79.12 12.47 C=120 0.205684 10'-0 Pf 2.057 74 17'-6 28.906 Pe 93 17-6 30.962 10'-0' Pv BL 1.610.0_ Q=106.67 16.81 C=120 0.35753410'-0i Pf 3.575 93 17'-6 30.962 Pe 108 17'-6 34.538 10'-0; Pv BL 1.6100 Q=135.70 21.39 C=120 0.558081 15'-0% Pf 12.843 108 17'-6 34.538 8'-0; Pe 149 17'-6 47.381 P0(5-0) 23'-0'% Pv CM 4.2600 Q=135.70 3.05 C=120 0.004883 10'-0 Pf 0.049 149 17'-6 47.381 Pe 148 17-6 47.430 10'-0' Pv • Route 3 DR 1.0490 Q=26.25 9.75 C=120 0.215281 29'-8% Pf 8.340 103 12'-0'% q=26.25 K=5.6 21.980 Spr(-21.980) 9'-0 Pe -2.375 59 17'-6 27.945 2E(2'-0), P0(5-0) 38'-8'/. Pv Route 4 DR 1.0490 Q=26.36 9.79 C=120 0.216886 25'-9 Pf 6.887 104 15'-0'% q=26.36 K=5.6 22.157 Spr(-22.157) 6'-0, Pe -1.075 32 17'-6 27.970 3E(2'-0) 31-9; Pv BL 1.6100 Q=26.36 4.15 C=120 0.026926 9'-2% Pf 0.247 32 17'-6 27.970 ' Pe 56 17'-6 28.217 9'-2% Pv - Route 5 DR 1.0490 Q=26.41 9.81 C=120 0.217696 31'-8% Pf 9.304 105 12'-0'% q=26.41 K=5.6 22.247 Spr(-22.247) 11-0 Pe -2.375 71 17'-6 29.176 3E(2'-0), P0(5'-0) 42'-8'/% Pv v Route 6 DR 1.0490 Q=26.68 9.90 C=120 0.221721 29'-8', Pf 8.589 106 12'-0% q=26.68 K=5.6 22.692 Spr(-22.692) 9'-0 Pe -2.375 74 17'-6 28.906 2E(2'-0), P0(5-0) 38'-8% Pv Route 7 ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:33AM Page 4 Hydraulic Analysis r Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K -Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length DR 1.0490 0=27.27 10.12 C=120 0.230990 31'-8%'' Pf 9.872 107 12'-0'% q=27.27 K=5.6 23.719 Spr(-23.719) 11'-0 Pe -2.375 90 17'-6 31.216 3E(2'-0), P0(5-0) 42'-8% Pv o Route 8 DR 1.0490 Q=27.56 10.23 C=120 0.235465 29'-8% Pf 9.121 109 12'-0'% q=27.56 K=5.6 24.216 Spr(-24.216) 9'-0 Pe -2.375 93 17'-6 30.962 2E(2'-0), P0(5'-0) 38'-8% Pv Route 9 DR 1.0490 Q=28.71 10.66 C=120 0.253927 31-8% Pf 10.852 110 12'-0'% q=28.71 K=5.6 26.275 Spr(-26.275) 11'-0 Pe -2.375 117 17'-6 34.753 3E(2'-0), P0(5'-0) 42'-8% Pv Route 10 DR 1.0490 Q=29.03 10.78 C=120 0.259243 29'-8% Pf 10.043 111 12'-0'% q=29.03 K=5.6 26.871 Spr(-26.871) 9'-0 Pe -2.375 108 17-6 34.538 2E(2'-0), P0(5'-0) 38'-8'/. Pv Equivalent Pipe Lengths of Valves and Fittings (C=120 only) r C Value Multiplier Value Of C Multiplying Factor 100 130 140 150 0.713 1.16 1.33 1.51 Actual Inside Diameter 14.87 = Factor Schedule 40 Steel Pipe Inside Diameter I Pipe Type Legend Units Legend Fittings Legend AO Arm -Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG UndergroundPv Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen -Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow - Eel 11W Elbow Ee2 22W Elbow f Flow Device FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap (E, ©M.E.P.CAD, Inc. inAutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:33AM Page 5 ©M.E.P.CAD, Inc. J AutoSPRINK®VR5 v5.2.6 06/05/2008 9:51:37AM Page 6 T f f Hydraulic Graph — I Job Number: KSO40 Report Description: Ordinary Group Supply at Node 1 150 Static Pressure 140.000 135 120 105 90 •N a :12- 520.45 —270.45 with hose @ 82.350 streams 75 0 N O1 a` 60 45 System demand curve 30 1 10900.00 @ 20.000 15 11LIIIIIItll 111111111 11111111 1 I I 1 1 I I 1 I 1 111111111 111111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 0 01002200 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.568 @ 520.45 System Demand 270.45 @ 82.350 System Demand (Including Hose Allowance) 520.45 @ 82.350 ©M.E.P.CAD, Inc. J AutoSPRINK®VR5 v5.2.6 06/05/2008 9:51:37AM Page 6 I 111 Flow Diagram (Top View) Job Number: KS0407 Report Description: Ordinary Group II R=. A © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/05/2008 9:51:40AM Page 7 FI ALARM SYSTEM DDITION UKWILA, WASHINGTON SHEET \Uv3E� SHEET TITLE FA -01 SYSTEV I\FO�fV ATI O \ FA -02 TYPICAL WI \G A\3 IVOU\TI\G DETAILS FA -03 SYSTEM CALCULATIO\S A\D SI\GLE LI\E DIAGA V FA -04 FI �E ALA V SYSTEIV PLA\ SHEET INDEX s1. 'ii' Without Comments p As Noted in Red p Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptanc is subject to errors and omissions which do not authorize violations of adopted standards and ordinances.. The responsfbllity for the adequacy of designr!..1.-:,.-: toaliv with the designer. Additions, deletions or reNisions to tnese drawings after this data will void this acceptance aru will require a resubmittal of revised drawings ror subsequent approval. Final acceptance is subject co field test and Inspection by The Tukwila Fire Prevention Bureau. Date: ° J By: f) i TUKWILA FIRS DEPARTMENT Please call 20E-575.4407 and give this Fre Permit No. 17-F- /SS - and exact atidrzas for shut- down or restarelton approval. WISE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY E 1 1 2 2 6 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD HT -D DUAL INPUT MONITOR MODULE HTRI-D SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING FIRE ALARM s SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2" EXTN CEILING EE TENANT J -BOX (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED GREEN BLUE AS BUILT ADD OR CHANGE AS BUILT REMOVE AS BUILT NOTES TO CAD N/A N/A N/A N/A N/A N/A SYMBOLS LEGEND N/A N/A N/A N/A N/A N/A IST AVE. SO., SEATTLE, WASHINGTON Iii uJ 1-- RELEASE/REVISIONS REV. BY: 2 DESCRIPTION SHOP DRAWINGS J DATE \ d, uJ 0 2a<<a< NORDSTROM macys 2I.LD jit] lo o 3N:NhCY i.Uf l�h JNCIRSS o utl `h �C2� „N PA..FNI,:F,. tElEli EGEI JCPenney .L� CLAIRE'f Fl. v'N nRFAM 1.J 10WailliVASHMKA .FR: t> CCFTS P77".)] BEAD? 1 -'Ir_.l i.. .._..L ill . fYS (.F II L & :OUNCE SAFARI #2800 / SPACE 2867 SITE PLAN cD co CV co OU -- r - • <o Q U) Z CC 2 • JO ~� �c LL. ccI }-w< Q 2 z� U� w ccOD 0 CO w H 0) 0) (S--CALE: NOT TO SCALE DRAWN BY: D. GARCIA 6U��A FIR NUMB R2086- y ./:) �A DjCAIS20DESIGNED BY: BACKROUND PLAN PROVIDED BY: ZO4'5y-r- SHEET T. QUAALE DATE: 08/1 4/17 FA -01 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved i THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. PUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET--\ \ SAMPLING TUBE INLET—\ SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ - DEDICATED EMERGENCY FROM EXISTING MAIN FACP C CABLE C' CABLE 0 000 GRD N L 0 L I1 0 PAD -3 00 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 S 0 0 0 Q 0 0 3.6k EOL 0 0 (-) (+) (-) (+) NAC S4 NAC S3 NAC S2 NAG S1 EXISTING POWER SUPPLY WIRING DETAIL COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE o � o HARD LID CEILING HARD LID - SPEAKER SUPPORT TILE BRIDGE --4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) FROM XLS CONTROL PANEL OR if PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH „.T 0 0 GROUND -0 �t- LC) 0 HTRI—R OSTATUS LED CO 0 N.O. 0 COM 0 N.0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. MUSIC STROBE SPEAKER (+) (- CC C (+) (- STROBE C 0 (+) STROBE SPEAKER (+) (-; "1 -AC POWER SOURCE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING RELAY CONTACTS (4.OA @ 125VAC) (4.OA @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL SPEAKER STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE HFP-11 TBI 0'010® 10 NO COM NC TO FAN SHUTDOWN EOLR 470 e TO NEXT 0 ” ? ADDRESSABLE DEVICE 0 //i// 00 HTRI-R 0 NO ® COM ® NCI 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERF�TIN TEMPERATU E: +32' F (0' C TO 100' F 3S C) HUMIDITY: bb0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE ---> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE r DATA IN( )> 1. DATA IN (+) > REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINS CEILING SUPPORT 0 0 0 0 > TO NEXT ADDRESSABLE DEVICE TO NEXT DEVICE ---CADDY BAR SMOKE DETECTOR--' SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SEATTLE, WASHINGTON FAX (206) 628-4990 w RELEASE/REVISIONS co co N co Z W co OU,— go L� Z .�... QJ0 CC � d < W cry) Q CI 2 LijZ W CCOD (n I-- 0 co N 47Cm 0 MOUTHING 4CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/1 4/17 BACKROUND PLAN PROVIDED BY: _OB NUMBER:26086-1J SHEET FA -02 � i SWITCH + — INPUT LED TSM -1 e TO NEXT 0 ” ? ADDRESSABLE DEVICE 0 //i// 00 HTRI-R 0 NO ® COM ® NCI 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERF�TIN TEMPERATU E: +32' F (0' C TO 100' F 3S C) HUMIDITY: bb0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE ---> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE r DATA IN( )> 1. DATA IN (+) > REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINS CEILING SUPPORT 0 0 0 0 > TO NEXT ADDRESSABLE DEVICE TO NEXT DEVICE ---CADDY BAR SMOKE DETECTOR--' SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SEATTLE, WASHINGTON FAX (206) 628-4990 w RELEASE/REVISIONS co co N co Z W co OU,— go L� Z .�... QJ0 CC � d < W cry) Q CI 2 LijZ W CCOD (n I-- 0 co N 47Cm 0 MOUTHING 4CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/1 4/17 BACKROUND PLAN PROVIDED BY: _OB NUMBER:26086-1J SHEET FA -02 � i Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 1 0.0022 0.0022 0.0023 0.002 FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps A B C D E F G H I J K FIRE ALARM BOOSTER Project:: SAFARI Panel: • EXISTING BPS PAD -3 Date: {August 14, 2017 Module/Device POWER REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 30 30 0 30 30 0 TOTAL FIRE ALARM POWER SUPPLY 30 30 Auxiliary Device Current 0: 0 Notification Appliance Load (Max. Total / mA) 0 , 4118 zaa<a Total(A)= 30 ' Total(B)= 4148 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 30 4148 Total current ratings converted to amperes (line D x .001) 0.03 4.148 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.72 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.3455284 Add lines G and I Total Standby and Alarm AH 1.0655284 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 1.27863408 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR); 7 Notification Appliance Circuit Detail PROJECT: SAFARI Panel: ' EXISTING BPS PAD -3 REMOTE POWER SUPPLY Date: August 14, 2017 Wire Resistance 2.58 CURRENT TOTAL= 4118.00 4 DEVICES .. SET -MC -CW @15cd SET -710076W 630cd, SET -MC -CW @75cd ZR -MC -CW @15cd ZR -MC -CW @30cd 69 111 200 69 111 TOTAL mA= Total'Wire Resistance (R ) Total Device Load, Amps (I) Voltage' Drop (E) . EOL Voltage 69 111 800 138 0 1118 14. 360 21.92 ' . :1118 (WL* 2 )'*.(R1ft). (Total Cct Load) 24 - E) 1.86 1.12 2:08 21.92 SET-MC-CWw15cd SET -MC -CW @30cd `SET-MC=,CW @75cd SET -MC -CW @95cd ZR -MC -CW @15cd DEVICES MAXIMUM LOAD 111 200 264 69 TOTAL mA= Total Wire Resistance (R ) Total Device . Load, Amps (I) Voltage Drop ( E ) EOL Voltage 0 0 0. 1500, 14 24.00 (WL * 2)* (R/ft) Total ccti7Pad) (E= I * R) 24.- E) 1500 0.00 1.50 0.00 24:00 SET -MC -CW @15cd SET -MC -CW @30cd SET -MC -CW @75cd SET -MC -CW @95cdw SET -MC -W @110cd ZR -MC -CW @304 1,1 DEVICES MAXIMUM LOAD 69 111 200 264 233' 111 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 0 .' 0 0 0 0. 1500' 14 24.00 1500 (WL*2)*(R/ft) 0.00 (Total Cct Load) 1.50 (E= I * R) 0.00 24 = E) . 24.00 SYSTEM CALCULATIONS TO EXISTING SPEAKER CIRCUIT TO EXISTING SPEAKER CIRCUIT TO EXISTING REMOTE BOOSTER POWER SUPPLY TO EXISTING DATA LOOP V S3-1 S3-2 S3-3 S,V V S,V y S,V y S,V y S,V S3-4 S3-5 S3-6 S3-7 S3-8 15cd 15cd 15cd 75cd 75cd 75cd 75cd 30cd (TENANT J -BOX) HT -R D b 3D D, I -c=p HT -R 2I TSM EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Iftm lfte 1743 IST AVE. SO., SEATTLE, WASHING T Oft FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 08/14/17 zaa<a ---- Cr 0 0 w z co co LU Z W co 00'- z o co z L .._.. Q _II_ �0 °CW� z LL c _ ) < "' Q Cl') (1) 2 w Z� 0 Lu CC o c0o 0 0 LU H- C,l`) CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/14/17 BACKROUND PLAN PROVIDED BY: \0B NUMBER:26086-12 SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET v1ALL_ CONCOUISEI CI ECK IN 1 ,' / S375 .� — — -75cd s.v mei S3-6 75cd S,V --o o-- S,V S3-4 75cd Eg S,V--o 00Nil C_. / S3-1 0 M I T-, s S3-3 15cd LA' AR EA troll I— HT-R REG j [4D I HT -R TSM rFiziS3-7 75cd S,V EOL S3 S3-8 30cd PAI- I Y P00k'l v—o—CD o—D 00 Ci) mo D D McX—n mu, --II� c 0Z 03Z o0 530 of,) 0 FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved GUARDIAN SECURITI 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 N X TEL. (206) 622-6545 GO z 0 GO w Ic UJ U) UJ J W CC REV. BY: 0 m 0 z 0 +z v w 0 SHOP DRAWINGS DATE 08/14/17 Cid co N Z W ccoo O U 0_o 0 C/)Z <JH d 4. F - LL >WCn < < %J W =J W 15 CC O D L-. um -- 0 co N �CALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/ 14/ 17 BACKROUND PLAN PROVIDED BY: JOB NUMBER:26086-1} SHEET FA -04 � i WESTFIELD SUITE 2867 FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \UM3ESHEET TITLE FA -01 SYSTEM INFORNATIO\ FA -02 TYPICAL DETAILS - WRI\G A\D \AOU\TI\G FA -03 FRE ALARM SYSTEM FLOOR PLAN. FA -04 SYSTEM CALCULATIO\S (GE\EAL), RISE, SITE PLA\ WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N . SYMBOL. DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIAT❑R TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9_ FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL. BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE. CABLE IS INSTALLED QUANTITY 1 2 2 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACK BOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP ® INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD I - < LINEAR BEAM I SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD A SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE ®D DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) gL C Dc FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM STROBE (CEILING MOUNT) SET -MC -CW SIEMENS SET -MC -W -SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 4S DEEP BOX W/ 1-1/2" EXT. CEILING 80" A.F.F. TO BOTTOM SET -HMC -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM © STROBE (WALL MOUNT) Y c ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING B WP MR FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) MULTI -VOLTAGE CONTROL RELAY SET -W SIEMENS SET -S17 -WP SIEMENS MR -201/C AIR PRODUCTS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. ... IN FIEL[ U -' y� , '' Without Comments IN FI ELI)t A.F.F. ABOVE FINISHED FLOOR N/A A / i As Notig4 Ai Red 0 Per e Attached Letter N/A F.B4O, FURNISHED BY OTHERS N/A A1ese plans have beetslc siewed by TheTukwila,F,ife Prevention Bureau for conformance with current city is to errors and N/A ANOT PPLICABLE N/A staiidardb. AccepUnce r.uhieot N &nissicns which do nolt ihorize violations of ado ted standards and ormnances. The responsibility for the the designer. aaaaa U.O.N. UNLESS OTHERWISE NOTED N/A adequacy of de.iyr i i bs toteCy with N Additions, deletions orroitsians to these drawir gs gtter this date will void this,aCCeptance and will require a WP WEATHERPROOF DEVICEFinal N/A resubmittal of revised drawings fai bubDequent approval. N A N/A N/A acceptance is subject to field test and inspection by ACO FII RED AS BUILTThe ADD OR CHANGE N/A Tukwila Fire Prevention bureau. N A N/A N/A By: 0700 Cert t( -.._. _ .... jDateA6r ., ,. mml GREEN REMOVE BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A 'TUKWILA FIRE DEPARTMi Tease call: 575.4407, ,and give this job ;end exact address for shut+ !Sown or restoration approvaai el) MOM Civ/05 NOTICE z IU ca z cc z r4) ON 1743 IST AVE. ON ON ao N .0 0 0 CV X• U - .o (V N 0 0 CV J UJ I - RELEASE/REVISIONS Do w EGH I DESCRIPTION SHOP DRAWINGS DATE 05/20/2008 9 aaaaa co 00 N arc; Lu22z I-Woc0 Cn 2 w= a �_� Q f-§ W w� . LL A vJ co1-7 (Nol D I.LI IF- mpleted, signed, T la 'e Department Pre -'test ificate must be presented the Inspector prior to nencement of Acceptance Testing of any Fire A arm and Detection Systems. Failure of test will result in a Re -inspection Fee and ination of the testing. PAM JUL - 9 2008# 171,66V7 (1) SCALE: 1/8" =1 ' DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE:05/20/2008 BACKROUND PLAN PROVIDED BY: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved \OB NUMBER: SHEET FA 01 , -,v,r7 S L a8z THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE A_ A STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR i+ PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) _L O SUPERVISED SWITCH ------ -' GROUND -4D 0 HTRI—R OSTATUS LED DUCT DETECTOR L❑CATI❑N N 0 0 0 N.O. COM N.0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 11 VOLTAGE MAX. - CURRENT MAX -- CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING=---\ TUBE INLET SAMPLING—\ TUBE \ \ AT LEAST SIX DUCT WIDTHS FROM BEND 1 TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE {(+;- FROM XLS CONTROL PANEL OR .[(+) PREVIOUS ADDRESSABLE DEVICE () END OF LINE DEVICE (3.6K 1/4W) RELAY CONTACTS <4.0A @ 125VAC) 0.0A @ 30VDC) 27 VDC 3.5 mA DURING -POLLING 10 OHMS 200 FT. (18 AVG) 0,02uF 0,04uF 14 AWG 18 AWG NOTE 21 ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTION, 0 k I TB1 soman 23456 HCP TB2 654321 0 N 7 SUPERVISED SWITCH i GROUND 0 0 HTRI—D OSTATUS LED CO 0 0 NOT USED 0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 nCND N AC I U 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1— 1 2+2— 2 NC C NO + — + — + — + — +.Ise — mmm��omm��m������me 24K n TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END OF LINE DEVICE 3.6K 1/4W) \SUPERVISED 1 SWITCH NAC -4 NAC -3 NAC -2 NAC -1 1 FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP.!. 0 0 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS EOL 0 INPU (+ t-) )P P1 IP 61 TSM -1 C 0 172:3:4-5- C C -1? _3 4.5, CQC e TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE 0 E FROM REMOTE POWER SUPPLY C'S' CABLE) FROM FACP <V❑ICE CIRCUIT) CV' CABLE) (+) (-) STROBE SPEAKER ('2 EARTH GROUND -->(+)TO NEXT DEVICE OR } .(-) STOP IF LAST DEVICE (STR❑BE) (STR❑BE) SPEAKER (+) (-) SPEAKER1STROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80" A.F.F. R 0 4S DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERtT1N TEMPERATU E: +32"F (0' C) TO 100" F 38' C) HUMIDITY: 0-9333333% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) >- DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE DB -11 STANDARD SMOKE DETECTOR BASE TO NEXT DEVICE -E- ( ) DATA OUT > (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING HARD LID ----•\ -----SPEAKER SUPPORT Ti — BRIDGE --- 4" SQUARE DEEP BOX .---- WITH 1-1/2" EXTENSION N. CEILING MOUNTED N SPEAKER/STROBE \. CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTI❑N BOX MOUNTED ON \\ CEILING FLEX \ JUNCTII MOUNTED A CEILING SI / / / / / / N BOX ---- iAINST PPORT 0 0 0 0 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING DO N.0 INSTA_L ADDRESSA LE IN DEVICES J INTI PREPROGRAM\ED W DEVICES ADDRESS. ITIATING TH z ©Q rn co a` 0 Fz (n w J t --- a LU O U) ra O a' a' co N X U- RELEASE/REVISIONS z DESCRIPTION SHOP DRAWINGS LLl Q 0 CO 0 0 N \ 0 N u7 0 O z C CD co co N —'c; W2�Z I_wcE0 w= W Q�' rrI- L 1.6.1 vJ CoD W E— SCALE: 1/8" =1 ' z 0 DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE:05/20/2008 BACKROUND PLAN PROVIDED BY: .OB NUMBER: SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ��—O2 2S,2V NORTH SUITE 2861 WESTFIELD SOUTHCENTER MALL SCALE 118":1' -i FLAG N ES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,CSEE SIEMENS INSTALLATI❑N SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLATOR FIRE SUPPRESION SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. DO \ ADD DEVICES J PRER.RO GRA DEVICES AD OT 0 \ S ALO ESSABLE MOT \TIL D AGING D WO ESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved -4 o rO O' 00 \ 00 N O `o O C) z N = v W F- F- LU - FW CD • Lo Cl).'? N LLj N a U) N —W RELEASE/REVISIONS REV. BY: I 0 W DESCRIPTION SHOP DRAWINGS DATE 05/20/20081 9aaa<a N. co co C 7.11111-5 <0) W 2 2Z - WHO D ��� .1I e-% 5 _< - ¢> C '1(0� N D w H SCALE: 1/8"=1' DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE:05/20/2008 BACKROUND PLAN PROVIDED BY: JOB NUMBER: SHEET FA -03} NORTH SUITE 2867 WESTFIELD SOUTHCENTER MALL SCALE 1132'=1' 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 115 C 115 C 75 C 15 15 EOL -S1 EX D,I 2I SYSTEM CALCULATIONS BATTERY SIZING CALCULATION 2867 2867 Wire Resistance 1.62 FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations Date: June 2, 2008 CURRENT TOTAL= 939 CIRCUIT: S1 Current Load: QTY Device Type Standby: Alarm: Wire Size Current Load: Voltage at EOL Circuit Total Standby: Alarm: 0 SET -MC @15CD 64 0 ■Total Wire Resistance ( R 0.86 0 @30CD 98 0 Device Type Qty Amps Total Amps Total Device Type Qty Amps ■ Total Amps Total HFP-11 0.0022 0.0022 0.0023 . (Total Cct Load) 2 : 636 AD2-P Voltage Drop (E) .,1 0.0635 0.0635 0.064 0.064 Main System Board 1 0.03 (E= I * R) 0.03 0.030 0.030 318 HTR -R 2 0.009600 0.0096 .0.021 0.042 19.59 SET -MC @15CD 445 0 0.064 (20.4 - E) HTRI-D 2 Z-MC@15CD 0.001600 128 0.0035 SET -MC @30CD 0 Z-MC@3OCD 0.098 0 ICP -B6 0.005 0 SET-MC-CW@11OCD SET -MC @75CD 0 1 0.175 0.175 DEVICES= 5 TOTAL mA= 939 12 265 19.5937746 • SET -MC @110CD 0.233 ION Notification Appliance Circuit Detail SET-HMC-C@115CD 2 PROJECT: 0.318 0.636 2867 Wire Resistance 2.58' . ` ., SET HMC-C@135CD Date: June 2, 2008 CURRENT TOTAL= 0.318 SPEAKER CIRCUIT 0.0731 Amps 0.106 Amps SET HMC-C@185CD U 0.445 Total- VVire Length Voltage at EOL. _ , ZR -MC @15CD 3 2 - 0.064 0.128 Standby Current Load: Total Wire Resistance (R) 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @3OCD (WL*2)*(R/ft) 0.098 0 ■Total HCP 0.01 0 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0 0 0.03 Amps 0.969 Amps • 0 0 (E= l * R) 0 0 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours , 0 0 0 0 Alarm Current Load: DEVICES= swimmii 0.969 Amps 5.4 For 5 Minutes= 0.081 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 1.002 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 1.002 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved Gotg CC CD 0' CO N 0 0 N X U- TEL. (206) 622-6545 RELEASE/REVISIONS m LU cr 0 w DESCRIPTION 0 uJ F- CO 0 0 N 0 N U) O << r J 0 W c co CC CO co ., N �� j W <Z ®C �- w cc 0 CC ZZ O CC e Q 0 � W Q �S w (cc � F- 0 Cf� N= W I- V J 0 LU C/) / SCALE: SEE SHEET DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 BACKROUND PLAN PROVIDED BY: \0B NUMBER: J SHEET FA -04 j 2867 Wire Resistance 1.62 Date: June 2, 2008 CURRENT TOTAL= 939 CIRCUIT: S1 QTY Device Type Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 0 SET -MC @15CD 64 0 ■Total Wire Resistance ( R 0.86 0 @30CD 98 0 (R/ft) 1 ■ Total Device Load, Amps (I) 0.94 0 . (Total Cct Load) 2 : 636 Voltage Drop (E) 0.81 0 445 (E= I * R) 0 0 SET -HMC @135CD 318 0 U EOL Voltage 19.59 SET -HMC @185CD 445 0 (20.4 - E) 2 Z-MC@15CD 64 128 0 Z-MC@3OCD 98 0 0 SET-MC-CW@11OCD 233 0 DEVICES= 5 TOTAL mA= 939 12 265 19.5937746 • ION Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL 2867 Wire Resistance 2.58' . ` ., Date: June 2, 2008 CURRENT TOTAL= 5.4 SPEAKER CIRCUIT U QTYAlarm Total- VVire Length Voltage at EOL. _ , 3 70.7V 1/81.8 - Total Wire Resistance (R) 2.92 0 (WL*2)*(R/ft) 0 ■Total Device Load, Amps (I) 0.01 0 0 (Total Cct Load} 0 0 Voltage Drop (E) 0.02 • 0 0 (E= l * R) 0 0 EOL Voltage 20.38 • 0 a 0 , 0 0 0 0 DEVICES= swimmii 3 TOTAL m A= 5.4 14 565 20.38425684 RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved Gotg CC CD 0' CO N 0 0 N X U- TEL. (206) 622-6545 RELEASE/REVISIONS m LU cr 0 w DESCRIPTION 0 uJ F- CO 0 0 N 0 N U) O << r J 0 W c co CC CO co ., N �� j W <Z ®C �- w cc 0 CC ZZ O CC e Q 0 � W Q �S w (cc � F- 0 Cf� N= W I- V J 0 LU C/) / SCALE: SEE SHEET DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 BACKROUND PLAN PROVIDED BY: \0B NUMBER: J SHEET FA -04 j MEM General Notes -too t's'i ./xo _is 4 tea - 3 -1 .t rr (le WORM. tttt itmtt1 1 z L• - dill 1 • - �-- A! milw . VLC1NITh MAP SCALE: NTS u ite#286-) 2867 SHELL SPACE 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain.. Western' States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. ZONE T9 EAST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE 27 Ordinary Group 11.0.200gpm/ft2 for 945.00ft2 030.53 i t4..1./ - '< % � p�FFY/ / 5 / .. ro , •/ r' // j w! �` % i /� . i v�Lr i 26� 15'.0" A.F.F 1NNEN= ■Y® iuuiii 11111111111 :11111111111111011111M1111111111 1w112:.9.1•��0 3111 ��� F I RIIIIIi� 1 mss'-ai%i� F��i 1111 1En aliiil•riNiU ra" - W' !liaidii 12'-0" A.F.F gele CM BM 27 ERIE SPRINKLERS_Y_3TENL EXISTING MAIN ZONE T9 8'-0" A.F.F 1 3 5 7 9 I TYPICAL FLEXABLE SPRINKLER CONNECTION: FLEXHEAD PIPE NIPPLE MOUNTING BRACKET ...tea .... SPRINKLER BRANCHLINE FLEXABLE CONNECTING' HOSE IN STANDARD LENGTHS # REDUCING FITTING SUSPENDED T -BAR GRID CEILING TILE SPRINKLER HEAD FLEXHEAD DETAIL NOT TO SCALE FIG 009 �r SNWELSWAY —� BRACE FITTING BRACE PIPE FIG. 1000 �"FASTCLAMP• SWAY BRACE ATTACI@AENT 3/0' KWIK BOLT r (2I W" EMBED LENGTH) LINE PIPE LATERAL LINE RESTRAINTS WIN -THREADED BRACE PIPE Remote Area 2867 SHELL SPACE CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 occuPANcv CLASS ORD HAZARD 1I MAX. COVERAGE per HEAD 130 FN DENSITY .20 GPM / Ft' for 945.0 Ft' I SPRINKLER Reliable F1 FR Semi-Rec ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 270.45 GPM © 78.90 PSI ' At time of Design 12'- 0" CI.G. = 37.00% AREA REDUCTION FIG. 4A PIPE CLAMP FOR SWAY BRACE 3/0` KWIK BOLT (2 1/4' EMBED LENGTH) FIG. 009 NO•THREAD SWIVEL SWAY BRACE ATTACHMENT Jl LATERAL BRANCHLINE RESTRAINT SP�fl NON•THREADED BRACE PIPE LATERAL BRANCIELINE RESTRAINT r 1 NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III / / HILTI KNI& Bolt 11 / ` Drilled Anchor -Et i( Cut Rod Lgth' Rounded to Nearest Inch Rod Coupling —� q. Swivel Ring Con Constru Bottom o Center L Note on Note on Plan: Hanger Number and 'A Dimension % // i nese plans have been reviewed by The Tukwila Fire artfIention Bureau for conformance with current city g'iandards. Aa.ceptance is subject to errors and omissions wh ch do not authorize violations of adopted starxlaras and ordinances. The responsibility for the on rete o quacy of d esig. n rests totally with the designer. dditions, del :tions or revisions to these drawings atter this date will vNoid this.acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire, Prevention Bureau / Without Comments As Noted In Red Per The Attached Letter HANGER DET Date: covoe By: 15-X0 k._ NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE I UI WILA FIRE. DEF'AR7iV�,U'd lease call: 575-4407 and give this job and exact address for shuts down or restoration approval, NOTICE Weld stamps must be inspected before pipe is hung.. Do not paint piping prior to hydrostatic test approval. • (0 co N CO lY w z Adam Kantner SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE. 0 R3615 32 5.6 Pendent 1/2.I Chrome 155°F F1FR Semi- Rec APPROVAL: City of Tukwila HYDRAULIC REFERENCE POINT R5415 10 5.6 Pendent White 155°F G4A Concealed CONT. NO.: KS0407 Total = 42 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 06/05/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 tic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY -OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/DECATUR/DENVER/DULUTH/HOUSTON/KANSAS CITY LAS VEGAS/MINNEAPOLIS/PHOENIX/PORTLAND /RAPID CITY/ ST. PAUL/SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 Vanilla Shell 2867 Southcenter Mall Tukwila ,Wa 98188 FRIE SPRINKLER SYSTEM 000 v SIiEL r FP -1 OF 1 �Lc 0 111- '-- 11111 /1 171-1:177;-, 1 a Vii► ^- ; 1��rrL �`. t<.{ r M �T-- u r. 11 1 �� General Notes l VICINITY MAP (Suite#2867) SCALE: NTS / x, 2867 SHELL SPACE 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. ZONE T9 EAST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE 27 Ordinary Group II.0.200gpm/ft2 for 945.00ft2 s• FRIE SPRINKLER SYSTEM 1/8"=1-0' 15'-0" A.F.F F 12'-0" A.F.F EXISTING MAIN ZONE T9 8' 0" A.F.F 28 TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD • MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING �%hW4�!N!T SUSPENDED T -BAR GRID �M��M�MY✓.nM.tl:wwtai>MyFria%•r..jW+:t.=M1'1"i.YM`>h l'.P(J�.+rArnt.. 11'...M.f.0,1PWr.r...,ANxis'yFP^4.:**1n+9M1,4101.,M,O,,109 404..,At@p•AIJd05RMW4WN SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE 3/9' KWIK BOLT - -• (21W EMBED LENGTH) FIG. 909 SWIVEL SWAY BRACE FITTING FIG. 1000 "FAST CLAMP' SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE Remote Area 2867 SHELL SPACE CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM / Ft` for 945.0 Ft' SPRINKLER Reliable Fl FR Semi-Rec ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 270.45 GPM © 78.90 PSI ' At time of Design 12'- 0" CLG. = 37.00% AREA REDUCTION FIG. 4A PIPE CLAMP FOR SWAY BRACE LATERAL BRANCHLINE RESTRAINT 3/9' KWIK BOLT (2 1W EMBED LENGTH) FIG. 909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT BRACE PIPE SA.._ to NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE / HILTI Kw& Bolt II Drilled An hor \ / Hanger No. 07C HILTI Kwik Bolt III Cut Rod Lgth Rounded to Nearest Inch Rod CoAll Thuplingread �` Concrete f Construction RodII -"Mi •:‹ 1111111111 Swivel Ring Pipe Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE Vanilla Shells 2867 CE W z 0 Adam Kantner Swinerton Builders CE 0 I- .z O U SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE HYDRAULIC REFERENCE POINT HANGER SYMBOL R3615 32 5.6 Pendent %' Chrome 155°F Fl FR Semi- Rec APPROVAL: City of Tukwila R5415 10 5.6 Pendent White 155°F G4A Concealed CONT. NO.: KS0407 BRANCHLINE RESTRAINT Total = 42 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 06/19/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN /DALLAS, DECATUR /DENVER /DULUTH /HOUSTON /KANSAS CITY LAS VEGAS /MINNEAPOLIS /PHOENIX /PORTLAND, RAPID CITY/ ST -PAUL/ SALT TAKE CITY/ SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 Vanilla Shells 2867 Southcenter Mall Tukwila ,Wa 98188 FRIE SPRINKLER SYSTEM SI -IEE T FP OF 1 1 (. 0 : t"1 `� 0 ,i..7 7 0 JQ i//,/i/, 27 ®j / `' /% , .// /; %//. / / / ' (t�' _ / , ' / 4•;..--.i'Li • S' •/ / � r/ ,/ "i / •• /. % •l/ ' / .' / ' /" ,// /' , , V.- , 4 Q 1 I N' . /'' i ,' N `' 71 / 74 C4 ' ' /' /%, %, ' / %f / /% , ; // / / / - / ./ ,/, i / , Qi _/ /.' to. / _ / i / / •'r /%• 1 N1 (Vv 1 l �X. , l' / ' /,_4,•.\ .ly / _ _ ` i / i i,�, /,�`// J' ,r/ of/r, !, /, / / • r,/to'/ , / ,'/// / / • • / + ' / / • • .r• 1/ % �•; ; `/. • / , /' / Ne �t5 t _ . oil ij ` ' tL' •` ; t; t 17 .i• : / / , i 5-9/:-- --- • fl IA I- 1'/' / i,, 9 'ti, !/' /L Q %' '/, /// �; /,•/ / 1/" r/:/j/,%/ /%/ / / • r/ '/// /`• //�,// /. — _i_T,, _ i IT ..._.,.[,N, ..t. - i -p Crj o t ,a oozy I ka _ t 44 1 ,A 5'-9%: 0 :11•1,1) %: «. 0 2'-0% e- 0 0 o e oa 6 PPPP , Ism 1631116311I� MS N» o• ::.? IV N r I A 'I + � NZ e01 :-.I WM `I ® . : ° , 14 zoa ? S taa 'S' 1 eat emm 149 emal - Y s I I s 'S ' ' .' um sib SO i ,4 (<. d`' 1 Ott° ok• 1 11 0. . 5-9% l'- a % 1 .. , 2'-0%: ' i to.- I O�CO' 1 �__�_L_ = 0'9® 0 0 0 O" 0 Och`C,/ ,� r y } 0�,� ...tom I 1._ 4e; -,c jj '®-_ic-ko "((\. 0d'`& 1 t' 1 OqV __ ci' 2-8'/+M1b 1.4 .O, FRIE SPRINKLER SYSTEM 1/8"=1-0' 15'-0" A.F.F F 12'-0" A.F.F EXISTING MAIN ZONE T9 8' 0" A.F.F 28 TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD • MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING �%hW4�!N!T SUSPENDED T -BAR GRID �M��M�MY✓.nM.tl:wwtai>MyFria%•r..jW+:t.=M1'1"i.YM`>h l'.P(J�.+rArnt.. 11'...M.f.0,1PWr.r...,ANxis'yFP^4.:**1n+9M1,4101.,M,O,,109 404..,At@p•AIJd05RMW4WN SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE 3/9' KWIK BOLT - -• (21W EMBED LENGTH) FIG. 909 SWIVEL SWAY BRACE FITTING FIG. 1000 "FAST CLAMP' SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE Remote Area 2867 SHELL SPACE CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM / Ft` for 945.0 Ft' SPRINKLER Reliable Fl FR Semi-Rec ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 270.45 GPM © 78.90 PSI ' At time of Design 12'- 0" CLG. = 37.00% AREA REDUCTION FIG. 4A PIPE CLAMP FOR SWAY BRACE LATERAL BRANCHLINE RESTRAINT 3/9' KWIK BOLT (2 1W EMBED LENGTH) FIG. 909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT BRACE PIPE SA.._ to NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE / HILTI Kw& Bolt II Drilled An hor \ / Hanger No. 07C HILTI Kwik Bolt III Cut Rod Lgth Rounded to Nearest Inch Rod CoAll Thuplingread �` Concrete f Construction RodII -"Mi •:‹ 1111111111 Swivel Ring Pipe Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE Vanilla Shells 2867 CE W z 0 Adam Kantner Swinerton Builders CE 0 I- .z O U SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE HYDRAULIC REFERENCE POINT HANGER SYMBOL R3615 32 5.6 Pendent %' Chrome 155°F Fl FR Semi- Rec APPROVAL: City of Tukwila R5415 10 5.6 Pendent White 155°F G4A Concealed CONT. NO.: KS0407 BRANCHLINE RESTRAINT Total = 42 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 06/19/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN /DALLAS, DECATUR /DENVER /DULUTH /HOUSTON /KANSAS CITY LAS VEGAS /MINNEAPOLIS /PHOENIX /PORTLAND, RAPID CITY/ ST -PAUL/ SALT TAKE CITY/ SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 Vanilla Shells 2867 Southcenter Mall Tukwila ,Wa 98188 FRIE SPRINKLER SYSTEM SI -IEE T FP OF 1 1