Loading...
HomeMy WebLinkAboutPP - 2876 SOUTHCENTER MALL - BOSSWEAR GIRLS - PERMITS AND PLANS2876 SOUTHCENTER MALL ASSOCIATED PERMITS 19-F-251 08-F-268 19-S-247 17-S-174 08-S-312 Ottwirt44 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Ci Z O Z y 7- o o t o Site Address: 2 70 W es a 1 mat Tenant Name: C Ac 0\ C Property Owner's Name: to € 5 r t e k A, Mailing Address: f O 6 0' ( (3 0 411i Suite Number: 24110 Floor: 2. New Tenant? ❑ - Yes ❑ - No Cqt- \5 b0.A CONTACT PERSON -if there are questions about the submittal. Name: 1 e s S\ C& e. b t ni3 City Company Name: C. ('OWN Y 1 re_ (('0 i n i1 Day Telephone: �N c CA 1Z°13 State Zip L -t z 5 L(I 17(0 !o 9 Mailing Address: Po 6 t (Z t 13 I 1 1 1 t( C A, g 0% Z City State Zip E-mail Address: , Q S) C(r) i , LO in Fax Number: LA 2 $ Y $ to Contractor's City of Tukwila NICET III number: Business License number: Q S- O 9 g S•gt Z. Total number of new/relocated devices or sprinkler heads: 3 Valuation of Project (contractor's bid price): $ 15-0 Scope of Work (please provide detailed information): R_ `6 (,Gl 5 64s r 4 -en, an V 1me(- e(\ -t kA- WesA-cek fln al PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGEN Signature: Print Name: Day Telephone: Plan Permit App.doc Date: q/ i /17 L/Z5562I40 8/22/14 TFD FP Form 8 -iN\-\N\ \e_A- 4.4"044 SITE LOCATION Site Address: CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Tenant Name:' C\Y \ Property Owner's Name:\ CA, D Mailing Address: \4t) CONTACT PERSON -if there are questions about the submittal. Name: C4) j \ Company Name: aq0CACs u1 S&L\ King Co. Assessor's Tax No.gpADIA-9 B B l V Suite Number: ,g\i D Floor: New Tenant? Yes ❑ - No \C4 --`gyp\ utc\thc0 NA C\RLA� City State Zip Mailing Address: t 4-5 \ -kqP _ J E-mail Address Day Telephon O %-7)p City State Zip Fax Number: ontractor's City of Tukwila NICET III number: Business License number:�S (i1 Total number of new/relocated devices or sprinkler heads: i 02 Valuation of Project (contractor's bid price): $ ()1 C)40. l Scope of Work (please provide detailed information):"( cx\o'(« t)\-\floi NI P \S`(e * , u(i\ulu1 0.)6\s04 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER OR AUTHORIZED AGENT: Signature: . Print Name: i!\ Date: `DI3 t tC1 TCUC (-y V\ Day Telephone00 i o) 1 b 34-(c Plan Permit App.doc 8/22/14 TFD FP Form 8 4.4w4v SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 /2-» FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be acted for plan review. **PLEASE PRINT"* ,� King Co. Assessor's Tax No.: Site Address: 2:87u �o I !^)ce.n rtTer Man Tenant Name: Soco.x'1 Property Owner's Name: VieSN'S'A-e fS0C Mailing Address: City Slate Zap CONTACT PERSON -if there lJ o aree}c�questions about the submittal Name: Cdr��r�'e 1CLbr�J�thDay Telephone: /vj'L/S1'71a.{Q,9 Company Name: C_.)TVU•DYN lr VY7Sic-eCti Mailing Address: T i 2\ 111 �'.--e-Z 1 `o dIU t t$ Z City State Zip E-mail Address: - �. i ** I • . • Fax Number. Contractor's City Tukwila NICET III number: • t ti` qi• CG Busies License number: Suite Number Floor. New Tenant? D - Yes 0 - No Total number of new/relocated devices or sprinkler heads: Vat ation of Project (contractor's bid price): $ 15O•C° ��,,,, Scope of Work (please provide detailed information): Acd c2) heads s PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant This figure wall be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TILE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER ORAUTHOW ED AGENT: Signature: Print Name: JCZiC 74>nSar) Play Permit App.doc */22114 Date: %2/5119 Day Telephone: qts .4 L / 76009 1713 FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Vanilla Box 2876 Southcenter Mall Permit No.: 08-S-312 Date: June 12, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • These conditions apply to any sprinkler piping exposed as necessary to accomplish the permitted scope of work. All references are NFPA 13, 2007 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Safari 2876 Southcenter Mall Permit No.: 19-S-247 Date: December 27, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe. Section 18.5.5. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions. Section 18.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line. Section 18.5.6. • Provide lateral and longitudinal bracing for changes in pipe direction per section 18.5.7. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement. Section 18.6. • Restraints for branch lines shall be at intervals per table 18.6.4 (a)(b) and section 18.6 and restrain sprig ups greater than 4'. Section 18.6.6. • Comply with ASCE 7-05. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • Weld stamps shall be inspected on the ground, before the pipe is hung. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2019 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Safari 2876 Southcenter Mall Permit No.: 17-S-174 Date: September 19, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. • Qi ©M.E.P.CAD, Inc. 4111AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:11 PM Page 1 Hydraulic Summary ` Job Number: KS0407 Report Description: Ordinary Group II Job Job Number Design Engineer KS0407 Adam Kanter Job Name State Certification/License Number Vanilla Shells 2876 WESTESF136QF Address 1 AHJ Southcenter Mall City of Tukwila Address 2 Job Srte Southcenter Mall City State Zip Code Drawing Name Tukwila Wa 98188 FP-1.cad System Remote Area(s) Most Demanding Sprinkler Data Occupancy 5.6 K -Factor 26.00 at 21.556 . Ordinary Group II Hose Allowance At Source Density Area of Application 250.00 0.20gpm/ft2 980.00ft2 (Actual 980.02ft2) Additional Hose Supplies ' Number Of Spnnklers Calculated Coverage Per Sprinkler Node Flow(qpm) 10 130.00ft2 Total Hose Streams 250.00 II , System Flow Demand Total Water Required (Including Hose Allowance) - , ', 61 283.21 533.21 r ' o7 Maximum Pressure Unbalance In Loops~ ''. 0.000 l_....\V_,Jilii:�i Maximum Velocity Above Ground ' --.. v 18.01 between nodes 176 and 216 liOr Maximum Velocity Under Ground �s 1.07 between nodes 1 and 434 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 2109.51 gal 1.22ft' Supplies Hose Flow Static Residual Flow Available Total Demand i Required ' Safety Margin Node (gpm) (psi) (psi) (gpm) (psi) (gpm) (psi) (psi) 1 250.00 140.000 20.000 10900.00 139.548 533.21 74.845 64.704 Contractor Contractor Number Contact Name Contact Trtle KS0407 Adam Kantner Project Manager Contractor Name Phone Extension Western States Fire Protection 425.881.0100 Address 1 FAX 7102 180th Ave Ne, Suite A-105 485.736.9032 Address 2 E-mail City State Zip Code Web -Site Redmond WA 98052 Qi ©M.E.P.CAD, Inc. 4111AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:11 PM Page 1 r Summary Of Outflowing Devices Job Number: KS0407 Report Description: Ordinary Group II lye ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:15PM Page 2 Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) Sprinkler 110 30.09 26.00 5.6 28.871 Sprinkler 109 29.62 26.00 5.6 27.969 Sprinkler 108 29.16 26.00 5.6 27.119 Sprinkler 106 28.73 26.00 5.6 26.319 Sprinkler 107 28.73 26.00 5.6 26.321 Sprinkler 105 28.32 26.00 5.6 25.567 Sprinkler 104 28.12 26.00 5.6 25.222 c;:. Sprinkler 101 26.00 26.00 5.6 21.556 Sprinkler 102 26.32 26.00 5.6 22.087 Sprinkler 103 28.12 26.00 5.6 25.221 c' Most Demanding Sprinkler Data lye ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:15PM Page 2 Node Analysis Job Number: KS0407 Report Description: Ordinary Group II Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 176 17-6 • 2P0(8-0) 45.239 177 17-6 2P0(8-0) 45.174 178 17-6 2P0(8-0) 45.164 216 15-6 P0(5-0) 37.256 218 15-6 P0(5-0) 37.424 239 15-6 P0(5-0) 34.948 241 15-6 P0(5-0) 35.174 257 15-6 P0(5-0) 33.896 259 15-6 P0(5-0) 34.149 278 15-6 P0(5-0) 40.609 286 15-6 E(2-0) 40.545 288 15-6 E(2-0) 33.883 294 15-6 E(2-0) 33.606 309. 15-0 fEE(3-5) 56.412 310 16-1 fEE(3-5) 56.102 312 14-0 fE(6-9%) 57.983 313 16-1 fE(6-9'/2) 56.781 434 3-10% BFP(-4.500) 71.396 459 1-11 P0(37-8%) 67.698 463 14-0 fE(10-0) 62.211 474 1-11 LtE(16-0) 67.712 110 12-0 Spr(-28.871) 28.871 30.09 109 12-0 Spr(-27.969) 27.969 ' 29.62 108 ' 12-0 Spr(-27.119) 27.119 29.16 106 12-0 Spr(-26.319) 26.319 28.73 107 12-0 Spr(-26.321) 26.321 28.73 105 I 12-0 Spr(-25.567) 25.567 28.32 104 15-0 Spr(-25.222) 25.222 28.12 101 15-0 Spr(-21.556) 21.556 26.00 102 15-0 Spr(-22.087) 22.087 26.32 103 15-0 Spr(-25.221) 25.221 28.12 1 , -4-0 S 74.845 283.21 ©M.E.P.CAD, Inc. 401 AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:18PM Page 3 49B Hydraulic Analysis Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Length Summary Length Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Eq. Total v Route 1 DR 1.049 Q=26.00 9.65 C=120 0.211435 51-3 Pf 12.531 101 15-0 q=26.00 K=5.6 21.556 Spr(-21.556) 8-0 Pe -0.204 288 15-6 33.883 4E(2-0) 59-3 Pv BL 1.610 0=26.00 4.10 C=120 0.026249 10-1 Pf 0.265 288 15-6 33.883 Pe 259 15-6 34.149 10-1 Pv BL 1.610 0=54.32 8.56 C=120 0.102571 10-0 Pf 1.026 259 15-6 34.149 Pe 241 15-6 35.174 10-0 Pv BL 1.610 0=83.04 13.09 C=120 0.224978 10-0 Pf 2.250 241 15-6 35.174 Pe 218 15-6 37.424 10-0 Pv BL 1.610 0=112.66 17.75 C=120 0.395541 9-9% Pf 8.617 218 15-6 37.424 12-0 Pe -0.867 177 17-6 45.174 2LtE(2-0), P0(8-0) 21-91/2 Pv CM 4.260 Q=168.91 3.80 C=120 0.007321 9-0 Pf 0.066 177 17-6 45.174 Pe 176 17-6 45.239 9-0 Pv CM 4.260 Q=283.21 6.37 C=120 0.019047 298-5% Pf 10.089 176 17-6 45.239 73-9 Pe 1.084 309 15-0 56.412 2E(13-2), 2cplg(-1.500), 4Ee2(5-3), 372-2% Pv P0(26-4) RN 4.260 Q=283.21 6.37 C=120 0.019047 1-6% Pf 0.159 309 15-0 56.412 fEE(3-5) 6-10 Pe -0.470 310 16-1 56.102 fEE(3-5) 8-4% Pv CM 4.260 Q=283.21 6.37 C=120 0.019047 35-8 Pf 0.679 310 16-1 56.102 Pe -0.000 313 16-1 56.781 35-8 Pv RN 4.260 0=283.21 6.37 C=120 0.019047 2-1 Pf 0.299 313 16-1 56.781 fE(6-9%) 13-7, Pe 0.903 312 14-0 57.983 fE(6-9%) 15-8 Pv CM 4.260 0=283.21 6.37 C=120 0.019047 205-2 Pf 4.228 312 14-0 57.983 16-9% Pe 0.000 463 14-0 62.211 fE(6-9%), fE(10-0) 221-11% Pv FM 6.357 0=283.21 2.86 C=120 0.002712 11-1% Pf 0.252 463 14-0 62.211 81-8% Pe 5.235 459 1-11 67.698 CV(40-3), GV(3-9%), PO(37-81/2) 92-10'', Pv FM 8.329 0=283.21 1.67 C=120 0.000727 3-7 Pf 0.014 459 1-11 _ 67.698 16-0 Pe -0.000 474 1-11 67.712 LtE(16-0) 19-7 Pv FM 10.420 0=283.21 1.07 C=120 0.000244 26-5% Pf 4.527 474 1-11 67.712 83-0 Pe -0.842 434 3-10% 71.396 4LtE(16-0), BV(19-0), BFP(-4.500) 109-5% Pv UG 10.400 0=283.21 1.07 C=140 0.000185 109-2 Pf 0.041 434 3-10% 71.396 111-7 Pe 3.407 1 -4-0 74.845 E(35-1), 3LtE(25-6), S 220-9% Pv Route 2 DR 1.049 0=26.32 9.77 C=120 0.216244 48-3 Pf 11.727 102 15-0 q=26.32 K=5.6 22.087 Spr(-22.087) 6-0 Pe -0.208 294 15-6 33.606 3E(2-0) 54-3 Pv BL 1.610 Q=26.32 4.15 C=120 0.026846 10-10 Pf 0.290 294 15-6 33.606 Pe 257 15-6 33.896 10-10 Pv BL 1.610 0=55.05 8.68 C=120 0.105145 10-0 Pf 1.051 257 15-6 33.896 Pe 239 15-6 34.948 10-0 Pv BL 1.610 0=84.21 13.27 C=120 0.230856 10-0 Pf 2.309 239 15-6 34.948 Pe 216 15-6 37.256 10-0 Pv BL 1.610 Q=114.30 18.01 C=120 0.406256 9-9'/2 Pf 8.850 216 15-6 37.256 12-0 Pe -0.867 176 17-6 45.239 2LtE(2-0), P0(8-0) 21-9% Pv .i Route 3 DR 1.049 0=28.12 10.44 C=120 0.244485 53-6 Pf 15.528 103 15-0 q=28.12 K=5.6 25.221 Spr(-25.221) 10-0 Pe -0.204 286 15-6 40.545 5E(2-0) 63-6 Pv BL 1.610 0=28.12 4.43 C=120 0.030352 2-1% Pf 0.065 286 15-6 40.545 Pe 278 15-6 40.609 2-1'% Pv BL 1.610 0=56.25 8.86 C=120 0.109422 37-6% Pf 5.421 278 15-6 . 40.609 12-0 Pe -0.867 178 17-6 45.164 2LtE(2-0), P0(8-0) 49-6% Pv (SM ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:21 PM Page 4 Hydraulic Analysis Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Eq. Length Summary Total Length Downstream Elevation Discharge K -Factor Upstream Pt Pn Fittings CM 4.260 Q=56.25 1.27 C=120 0.000957 10-6 Pf 0.010 178 17-6 177 17-6 45.164 45.174 Pe 10-6 Pv Route 4 DR 1.049 0=28.12 10.44 C=120 0.244498 52-9 Pf 15.591 -0.204 104 15-0 q=28.12 K=5.6 278 15-6 25.222 40.609 Spr(-25.222) 3E(2-0), P0(5-0) 11-0 Pe 63-9 Pv v Route 5 DR 1.049 Q=28.32 10.51 C=120 0.247588 29-9 Pf 10.087 -1.506 105 12-0 q=28.32 K=5.6 259 15-6 25.567 34.149 Spr(-25.567) 3E(2-0), P0(5-0) 11-0 Pe 40-9 Pv ill Route 6 DR 1.049 . 0=28.73 10.66 C=120 0.254314 29-9 Pf 10.361 -1.506 106 12-0 q=28.73 K=5.6 241 15-6 26.319 35.174 Spr(-26.319) 3E(2-0), P0(5-0) 11-0 Pe 40-9 Pv Route 7 DR 1.049 0=28.73 10.67 C=120 0.254337 26-8% Pf 9.081 -1.506 107 12-0 q=28.73 K=5.6 257 15-6 26.321 33.896 Spr(-26.321) 2E(2-0), P0(5-0) 9-0 Pe 35-8% Pv 4 Route 8 DR 1.049 Q=29.16 10.83 C=120 0.261455 26-8% Pf 9-0 Pe 35-8% Pv 9.335 -1.506 108 12-0 q=29.16 K=5.6 239 15-6 27.119 34.948 Spr(-27.119) 2E(2-0), P0(5-0) Route 9 DR 1.049 0=29.62 10.99 C=120 0.269030 29-9 Pf 11-0 Pe 40-9 Pv 10.961 -1.506 109 12-0 q=29.62 K=5.6 218 15-6 27.969 37.424 Spr(-27.969) 3E(2-0), P0(5-0) v Route 10 DR 1.049 0=30.09 11.17 C=120 0.277043 26-8% Pf 9-0 Pe 35-8% Pv 9.892 -1.506 110 12-0 q=30.09 K=5.6 216 15-6 28.871 37.256 Spr(-28.871) 2E(2-0), P0(5-0) Equivalent Pipe Lengths of Valves and Fittings (C=120 only) ` C Value Multiplier Actual Inside Diameter 4.87 ) Value Of C 100 Multiplying Factor 0.713 130 1.16 140 1.33 150 1.51 = Factor ( Schedule 40 Steel Pipe Inside Diameter © M.E.P.CAD, Inc. 4111 AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:21 PM Page 5 1111 Hydraulic Analysis Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Elevation Upstream Discharge K -Factor Pt Pn Fittings Length Pressure Eq. Length Summary Total Length Pipe Type Legend Units Legend Fittings Legend AO BL CM DN DR DY FM FR MS OR RN SP ST UG Arm -Over Branch Line Cross Main Drain Drop Dynamic Feed Main Feed Riser Miscellaneous Outrigger Riser Nipple Sprig Stand Pipe Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22'/z Elbow f Flow Device FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD, Inc. j�AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:21 PM Page 6 11 I Hydraulic Graph I Job Number: KS0407 Report Description: Ordinary Group II Supply at Node 1 150 Static Pressure 140.000 135 120 105 90 .N a `i with hose streams 75 N CA a1 a` ,533.21 -283.21 @ 74.845 60 45 System demand curve 30 10900.00 @ 20.00011 15 w 111111111 111 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0100 01002200 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.548 @ 533.21 System Demand 283.21 @ 74.845 System Demand (Including Hose Allowance) 533.21 @ 74.845 f[ ©M.E.P.CAD, Inc. AutoSPRINKO VR5 v5.2.6 06/02/2008 3:08:30PM Page 7 Flow Diagram (Top View) Job Number: KS0407 Report Description: Ordinary Group II ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:34PM Page 8 SOUTH CENTER MALL SAFARI FIRE ALARM SYSTEM ADDITION TU ILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET # SHEET TITLE FA -01 SYSTEfv INFO VIATIO\ FA -02 TYPICAL WHI\G A\ 3 V OU\TI\G DETAILS FA -03 FLO0FRE ALARM PLA\ /CALCULATIONS SI\GLE LI\E DIAGAIv SCOPE OF WORK ADD 4 NEW CEILING MOUNT SPEAKER/STROBE, ADD THREE(3) NEW STROBE, AND INSTALL INTELLIGENT INITIATING DEVICE TO SHUTDOWN MUSIC AND DUCT DETECTOR INTERFACE MODULE TO AN EXISTING FIRE ALARM SYSTEM. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NEPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE TEE CABLE IS INSTALLED QUANTITY 4 1 1 3 1 2 E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT [5 FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW (1/2W - 70.7V) SIEMENS 4S BOX CEILING TSM DUCT DETECTOR TEST SWITCH (NEW) TSM- 1 SIEMENS 4S DEEP BOX VERIFY IN FIELD ADDRESSABLE SMOKE DETECTOR (NEW) HFP-11 W./ DB -11 BASE SIEMENS EXISTING CEILING FIRE ALARM STROBE (NEW) ZR -MC -CW SIEMENS EXISTING CEILING DUCT HOUSING O WITH DETECTOR (NEW) FDBZ492-HR W/ HFP-11 DET SIEMENS DUCT HOUSING VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY (NEW) HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD DE (EX ST NG) NCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD E EXISTING DEVICE N/A N/A N/A N/A A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT • APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A ' Without Comments a As Noted in Red O Per The Attached Letter hese plans have been reviewed by ThF:: Tukwila Fire ,ention Bureau for conformance current City ldards. Acceptance is subject to erwrs and ,.;slons which do not: authorize Ficial orfs of adopted dards and ordinances.. The responsIbillty for the -.luacy of design rests totally with the designer, ditions, deletions or revisions to these drawings after date will void t.th is acceptance and wi'.i require a resubmittal of revised drawings for subsequent approval, Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: / 30 -15 By:Al"-‘,J Fire Permit Number To schedule. inspections call 206-575-4407 REVIEWED BY: ANTHONY MEDAWAR, CET NICET LEVEL III, FIRE ALARM SYSTEMS NICET ID: 144058 VALID THROUGH: FEBRUARY 1, 2023 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved rs0 0-5 Cr z O H- z W > QIlad Citt- FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I WIRE DESIGNATION 0 rr SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C D S S' V V I POWER SUPPLY SYNC TWISTED PAIR WITH SHIELD #14 FPLP DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP SPEAKER CIRCUIT - FEED TWISTED PAIR #16 FPLP SPEAKER CIRCUIT - RETURN TWISTED PAIR #16 FPLP INITIATING CIRCUIT TWO #18 FPLP RECORD DRAWINGS CONDUIT FILL CHART DATE NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS TWO 600V #12 AWG THHN/THWN .244 O.D. TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. TWO CONDUCTOR 300V #18 AWG FPL 1W CABLE .156 O.D. CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. AREA .0467 .0346 .0191 SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NEPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE TEE CABLE IS INSTALLED QUANTITY 4 1 1 3 1 2 E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT [5 FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW (1/2W - 70.7V) SIEMENS 4S BOX CEILING TSM DUCT DETECTOR TEST SWITCH (NEW) TSM- 1 SIEMENS 4S DEEP BOX VERIFY IN FIELD ADDRESSABLE SMOKE DETECTOR (NEW) HFP-11 W./ DB -11 BASE SIEMENS EXISTING CEILING FIRE ALARM STROBE (NEW) ZR -MC -CW SIEMENS EXISTING CEILING DUCT HOUSING O WITH DETECTOR (NEW) FDBZ492-HR W/ HFP-11 DET SIEMENS DUCT HOUSING VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY (NEW) HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD DE (EX ST NG) NCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD E EXISTING DEVICE N/A N/A N/A N/A A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT • APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A ' Without Comments a As Noted in Red O Per The Attached Letter hese plans have been reviewed by ThF:: Tukwila Fire ,ention Bureau for conformance current City ldards. Acceptance is subject to erwrs and ,.;slons which do not: authorize Ficial orfs of adopted dards and ordinances.. The responsIbillty for the -.luacy of design rests totally with the designer, ditions, deletions or revisions to these drawings after date will void t.th is acceptance and wi'.i require a resubmittal of revised drawings for subsequent approval, Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: / 30 -15 By:Al"-‘,J Fire Permit Number To schedule. inspections call 206-575-4407 REVIEWED BY: ANTHONY MEDAWAR, CET NICET LEVEL III, FIRE ALARM SYSTEMS NICET ID: 144058 VALID THROUGH: FEBRUARY 1, 2023 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved rs0 0-5 Cr z O H- z W > QIlad Citt- FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I 0 0om rr 0 rr DESCRIPTION SHOP DRAWINGS RECORD DRAWINGS DATE 12/20/19 11/04/19 rn CALE: NOT TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 12/20/ 19 BACKROUND PLAN PROVIDED BY: \OB NUMBER:49800-1) SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL HARD LID \� CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE 4" SQUARE BOX CEILING MOUNTED SPEAKER/STROBE (OR STROBE ONLY) SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM PREVIOUS ADDRESSABLE DEVICE 2 SWITCH INPUT MUSIC SHUTDOWN 00 22 FDBZ492-HR TB1 NO COM NC 2 TO FAN SHUTDOWN 22 0 -®I 2 00 a HTRI-R 0 NO e COM NC 0 0 9/2) 00 EOLR --vv 470 0 0 SWITCH + - INPUT LED TSM -1 e ADDRESSABLE DEVICE TO NEXT 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL FROM EXISTING TENANT J -BOX FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V CABLE) SPEA (+) <ER fl (-) BI 3 4 5 0 0 e HTRI-R 0 NO e COM ® NC 0 0 U (+) ST (- REEE (+) ST RE3E SPEA (+) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE REVIEWED BY: ANTHONY MEDAWAR, CET NICET LEVEL III, FIRE ALARM SYSTEMS NICET ID: 144058 VALID THROUGH: FEBRUARY 1, 2023 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 m DESCRIPTION SHOP DRAWINGS RECORD DRAWINGS DATE 12/20/19 11/04/19 CC U- Q O Q °co ° C/) _ E C'S o Q a4:2 WWZ iz ) z I- �(d =S W I CC oD u CV D 0 U) SCALE: NOT TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 1 2/20/1 9 BACKROUND PLAN PROVIDED BY: .,JOB NUMBER:49800-1,i 1 SHEET FA -02 VORK A.6.1 CA) STORAGE 203 -S1-4 11OCd V1-1 1/2W EOL S1-7 Si 75Cd V1-4 1/2W PARTY ROOM PLAY AREA CG AREA OF WORK NEW ADDITIONAL DEVICES SPEAKER/STROBES S1-5 75Cd V1-2 1/2W CHECK-IN 40, • 111161111111 MOM IMMO MOII 000 FLOOR FIRE ALARM PLAN SCALE: 3/16" = 1'-0" V TSM SHUTDOWN MUSIC D I c IHT-R� Notification Appliance Circuit Detail PROJECT: 1 SOUTH CENTER MALL SAFARI Panel: ; EXISTING(TENANT) POWER SUPPLY Wire. Resistance 2.58 SET MC-CW(aAI5Cd S ET111I C-CW6,30 SET MC-CW@75Cd SET-MC-CWrvP„955Cd `ZR -M C-CWp,15Cd -enc Iocd ZR -M C-CWA75Cd ZR -M C-CW95Cd 69' 111, 200! 264 69' 207' 800 111 200 TOTAL m A= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage ... , 1007 14 (WL*2)*(Rift (Total Cct Load (E=I*R) .24-_E 1.11 .01 1.12 22.88 SPEAKER CIRCUIT ADD-ONS PROJECT `SOUTH CENTER MALL SAFARI Panel: EXISTING XLSV FACP Date: December 20, 2019 Wire Resistance 2.58 CURRENT TOTAL= 28.8 0 '70.7V 1/8 -WATT 70.7V1/4 -WATT 70.7V 1/2 -WATT p; 707V1 -WATT, DEVICES= '4 7.2 28.8 14:4 0:.;. TOTAL m A= ' 2 8.8 Total Wire Resistance ( R ) Total Device Load, ` Amps (I) Voltage Drop (E ) EOL Voltage 16 20.4 WL*2)*(Rift) (Total Cct Load '(E= I*R) (24, - E). 0.00 0.03 0.00 24.00 CALCULATIONS FROM EXISTING ) SPEAKER STROBE C V E EXISTING TENANT J -BOX S1-1 15Cd S1-2 15Cd S1-3 15Cd SINGLE LINE DIAGRAM NOT TO SCALE S1-4 75Cd V1-1 2W S TO NEXT DEVICES ) SPEAKER STROBE V6 S1-5 75Cd V1-2 2W S1-6 75Cd V1-3 2W S1-7 75Cd V1-4 1 2W L REQ IC NIC VALID BY: ANTHONY MEDAWAR, CET NICET LEVEL III, FIRE ALARM SYSTEMS NICET ID: 144058 VALID THROUGH: FEBRUARY 1, 2023 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 03 Ct DESCRIPTION SHOP DRAWINGS DATE 0) 0 N N z aaaa< O Q co 00 o frz < 0 2 cc 0 ▪ Z = CO z co0< re • I— D er wL1.1 CID ▪ N aC LLI OC u 0 0 �CALE:3/16"=1'-0" DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 12/20/19 BACKROUND PLAN PROVIDED BY: •JOB NUMBER:49800-1} SHEET FA -03 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ( WESTFIELD SUITE 2170 FIRE ALARM SYSTEM TUKWILA, WASHINGTON ( SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \UVI3ESHEET TITLE FA -01 SYSTEM INFO .MATIO\ FA -02 TYPICAL DETAILS - WRING A\D MOU \TI \ G FA -03 FRE ALARM SYSTEIv FLOG PLA\ FA -04 SYSTEM CALCULATIO\S GE \E�AL), �ISE�, SITE PLAN WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIAT❑R TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL • BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT, AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF 'NEPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD : DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED 'ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT.: 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS, USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION, OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 3 2 1 2 2 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD B a LINEAR BEAM SMOKE DETECTOR. PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE D DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING gL C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM STROBE (CEILING MOUNT) L❑ Q C FIRE ALARM STROBE (WALL MOUNT) FIRE ALARM SPEAKER (CEILING MOUNT) SET -MC -CW SIEMENS SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 4S DEEP BOX W/ 1-1/2" EXT. CEILING 80" A.F.F. TO BOTTOM SET -HMC -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING Y WP MR FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) MULTI -VOLTAGE CONTROL RELAY SET -W SET -S17 -WP MR -201 /C SIEMENS SIEMENS AIR PRODUCTS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. VERIFY IN MELD FA JBOX FIRE ALARM TERMINAL CABINET O JUNCTI❑N BOX F.B.O. F.B.O. F.B.O. a F.B.❑. N / A F.B.O. GCE TED UVithout Comments VER IFY IN IELD VERFY IN ilELD A.F.F, ABOVE FINISHED FLOOR N/A - K/A (] As Noted Inl N/A o Per The Attached Letter F.B,❑. FURNISHED BY OTHERS N/A i nUablans have been revirdi by The Tukwila Firs/A Prevention Bureau for conformance with current city A comple N/A NOT APPLICABLE N/A st rds. Acceptance is 5 1 )A -t to errors and o Ions which do not autho� a violations of adopt iA standards and ordinances. The responsibility for the Fire De Certificat U.O.N. UNLESS OTHERWISE NOTED N/A ad'�,�Y of design rests_totall with the designer. Adei"tiens, deletions or reviskiiAo these drawings atE1A this date will void this acceptance and will require a to the comment Testinc WP WEATHERPROOF DEVICE N/A rest.92wittalofrevised drawliviSjorsubsequent appr9rIA Final ac�ptande is cr,To field test and inspection by and C FailurE RED AS BUILT ADD OR CHANGE N/A kwila Fire,Preventio eau. �� N/A r O Date: .. By' in a Re termini r;PFFN AS BUILT N/A N/A N N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright FIRE Mall please call: end give this job and r crownorexact restorationress oapP approval/ 2006 by Guardian Security Systems, r) FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS .\/ CO T < co W 2Z WWO ZZ CO 2 ILu = NOTICE 0 cc i Q ted, signed, TukWil -'J < = apartment Pre-test W W O e must be presenteE cc (1) S Inspector prior to ement of Acceptar of any Fire Alarm etection Systems. of test will result inspection Fee and Ition of the testing, E PAID 1 - 2008 Tukwila Fire �zfrg/ Inc. All Rights Reserved UL ND W Z 0 0 z CALE: 1/8" =1 ' DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 BACKROUND PLAN PROVIDED BY: .OB NUMBER: SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE �+ STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR -C+ PREVI❑US ADDRESSABLE DEVICE - END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH O DUCT DETECTOR LOCATION GROUND -- CV LI ) raj HTRI—R STATUS LED N.O. COM --- - - N.C. _--%- NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL (ABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE_ DEVICE TO NEXT ADDRESSABLE DEVICE L - + NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX, CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE- OUTLET SAMPLING---•\ TUBE INLET SAMPLING—\ TUBE \ AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE MUSIC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE{+)__ STOP IF LAST DEVICE {{-)-- FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE {-)-- RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) 27 VDC 3,5 r+1A DURING POLLING 10 OHMS 200 FT. (18 AWG) 0,02uF 0,04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTION. O J I0 01 TB1 50000 23456 HCP TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE O ' END OF LINES DEVICE (3,6K 1/4W) SUPERVISED SWITCH GROUND r0 CV Pr) HTRI—D --STATUS LED 0 NOT USED FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE + DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0 0 {FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE POWER SUPPLY ('S' CABLE) END OF ' LINE DEVICE FROM . FACP 6..3,6K 1/4W) (VOICE CIRCUIT) O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABEL (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC 111 0 0 0 CI Dl II 0 PAD -3 0 0 00 O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1— 1 2+ 2— 2 NC C NO + — + — + — + — + — 0a11s2.ea_a_ 4. 4.a� 24K + NAC -4 NAC -3 NAC -2 NAC -1 ('V' CABLE) SUPERVISED 1 SWITCH 470 OHMS EOL TCM -1 C TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NDE u �.J (STROBE) SPEAKER (+) () ((- STROBE EARTH GROUND 0 --)-(+)TO NEXT DEVICE OR 1 >(-) STOP IF LAST DEVICE (STR❑BE) SPEAKER (+) (—) 0 SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY R 80" A.F.F. O O 4S DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERPIIN TEMPERATU E: +32'F (0' C) TO 100' F 38 C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFI' -11 SMOKE DETECTOR -3► FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) >- 1. DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICE 4— ( ) DATA OUT (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID —\. CEILING --------SPEAKER SUPPORT TILE -- BRIDGE HARD LID -- 4' SQUARE DEEP BOX ,, WITH 1-1/2' EXTENSI❑N - CEILING MOUNTED N SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTION BOX---,. MOUNTED ON \ CEILING FLEX \ JUNCTIDN BOX ---- MOUNTED AGAINST CEILING SUPPORT / A O 0 7g5 I TO NEXT DEVICE CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE of SUSPENDED ILLUMINATED CEILING DO \OT I\STA_L ADDRESSA LE N HAT DEVICES %INTI_ PREPROGRAMMED WIT DEVICES ADDRESS. NG Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS w DESCRIPTION SHOP DRAWINGS LLJ F— a 00 0 0 N 0 N 0 0 z 0 OD OD CTJ ¢0) �— w00 0 2.i ?(,)Q W Wp c _� F- W alp F- 23: DRAWN - J z F - z 3 0 0 z (1) a. 0 z E SCALE: 1 /8"=1 DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE:05/20/2008 BACKROUND PLAN PROVIDED BY: `OB NUMBER: SHEET FA -02 } IL -C 1' I Fri 23'- 2„ i r -`. r_� F \- 2s,2V D,I 2I SM D,I ' 2I s 2V 35'-2" 115 C NORTH El L 115 C SUITE 2110 WESTFIELD SOUTHCENTER MALL SCALE 118"=1' FLAG \ OTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATI❑N SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLATOR FIRE SUPPRESI❑N SYSTEM, FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT, DO NO INS AL_ ADDRESSABLE IIT DEVICES U\ IL PREPROGRAVMED W DEVICES ADDRESS. ATI N G Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved v W cc a 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 C/) Z O (1) W CC W C/) w J W REV. BY: EGH z O a_ E Cf)U w SHOP DRAWINGS 0 DATE 05/20/2008 2aa«< J O CO CO T 00; WO Iz E-0 w= ❑ <_0) J Q D� WwO LL 5 1-W° W CV D F- I SCALE:1/8"=1' DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 BACKROUND PLAN PROVIDED BY: .J..0B NUMBER: r SHEET FA-O3� `IfffTTfr NORTH SUITE 2110 WESTFIELD SOUTHCENTER MALL SCALE 1132°=1' S,2V S,2V 2S,2V 2S,2V 2S,2V b C 115 C 115 75 15 EOL -S1 15 EX FACP RISER DIAGRAM SYSTEM CALCULATIONS BATTERY SIZING CALCULATION Panel: SUITE 2170 SUITE 2170 Wire Resistance 1.62' FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations Date: June 3, 2008 CURRENT TOTAL= 939 DATE CIRCUIT: S1 9 CCaCa Current Load: QTY Device Type Standby: Alarm: Wire Size Current Load: Voltage at EOL Circuit Total Standby: Alarm: SET -MC @15CD 64 0 Total Wire Resistance (R) 0.86 0 SET -MC @30CD 98 0 Device Type Qty Amps Total Amps Total 175 Device Type Qty Amps Total Amps Total SET -MC @11 OCD HFP-11 0 0.0022 0.0022 0.0023 (Total Cct Load) 2 SET-HMC-C@115CD 318 636 AD2-P Voltage Drop ( E) 2 0.0635 0.0635 0.064 0.128 Main System Board 1 0.03 (E= I * R) 0.03 0.030 0.030 318 HTR -R H TR I -D ICP -B6 3 0.009600 0.0096 0.021 0.063 19.59 SET -MC @15CD SET -MC @30C D SET -MC @75CD SET -MC @110CD SET HMC-C@115CD SET HMC-C@135CD SET HMC-C@185CD ZR -MC @15CD ZR -MC @30CD HCP 445 0 0.064 (20.4 - E) 0.001600 2 0.0035 64 128 0.098 0 0.005 98 0 1 0.175 0.175 SET-MC-CW@110CD 233 0 DEVICES= 5 0.233 939 12 265 19.5937.746) 939 2 0.318 0.636 Notification Appliance Circuit Detail 'PROJECT: WESTFIELD SOUTHCENTER MALL 0.318 Panel: 2170 0.0731 Amps 0.191 Amps June 2, 2008 CURRENT TOTAL= 7.2 0.445 CIRCUIT SPEAKER CIRCUIT 2 QTY Device Type . 0.064 0.128 Wire Size Standby Current Load: Voltage at EOL 0.0731 Amps For 24 Hours = 1.754 Amp -hours 1.8 7.2 0.098 Total Wire Resistance (R) 2.92 0 0 0 (WL*2)*(R/ft) 0.0015 0 Alarm Current Load: 0.191 Amps For 5 Minutes= 0.016 Amp -hours 0.01 0 0 0.03 Amps 0.969 Amps (Total Cct Load) 0 0 0 Voltage Drop (E) 0.02 0 0 0 25% Derating= 2.213 Amp -hours Standby Current Load: (E=I*R) 0.03 Amps For 24 Hours = 0.720 Amp -hours EOL Voltage 20.38 0 0 0 (20.4-E) 0 0 . 0 Alarm Current Load: 0.969 Amps . 0 For 5 Minutes= 0.081 Amp -hours 1 Total System Current Load: 2.213 Amp -hours 4 TOTAL mA= 7.2 14 565 20.37900912 7.2 25% Derating= 1.002 Amp -hours Battery Pair to be Used: 12VDC [Amp -hours 7AH Total System Current Load: 1.002 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION Panel: 2170 Wire Resistance 1.62' Date: June 3, 2008 CURRENT TOTAL= 939 DATE CIRCUIT: S1 9 CCaCa QTY Device Type Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total SET -MC @15CD 64 0 Total Wire Resistance (R) 0.86 0 SET -MC @30CD 98 0 ( WL * 2 )* (R/ft) 1 SET -MC @75CD 175 175 Total Device Load, Amps (I) 0.94 0 SET -MC @11 OCD 233 0 (Total Cct Load) 2 SET-HMC-C@115CD 318 636 Voltage Drop ( E) 0.81 0 SET-HMC-C@177CD 445 0 (E= I * R) 0 SET -HMC @135CD 318 0 EOL Voltage 19.59 0 SET -HMC @185CD 445 0 (20.4 - E) 2 Z-MC@15CD 64 128 0 Z -MC @30C D 98 0 0 SET-MC-CW@110CD 233 0 DEVICES= 5 TOTAL mA= 939 12 265 19.5937.746) 939 Notification Appliance Circuit Detail 'PROJECT: WESTFIELD SOUTHCENTER MALL Panel: 2170 Wire Resistance 2.58 Date: June 2, 2008 CURRENT TOTAL= 7.2 CIRCUIT SPEAKER CIRCUIT QTY Device Type . Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total ■ 4 70.7V 1/8 1.8 7.2 Total Wire Resistance (R) 2.92 0 0 0 (WL*2)*(R/ft) 0 0 0 Total Device Load, Amps (I) 0.01 0 0 0 (Total Cct Load) 0 0 0 Voltage Drop (E) 0.02 0 0 0 (E=I*R) 0 - 0 0 EOL Voltage 20.38 0 0 0 (20.4-E) 0 0 . 0 0 . 0 0 1 DEVICES= 4 TOTAL mA= 7.2 14 565 20.37900912 7.2 VOLTAGE DROP CALCULATION co O 0 z_ U) W I- I - w 0 U) ui U) r` O ON W N N X RELEASE/REVISIONS REV. BY: I EGH DESCRIPTION SHOP DRAWINGS DATE 05/20/2008 9 CCaCa W Ct W o coCO N ._,_i CO W § z < ~ W imp cc D W ZZ Ci) V<2(1) = a V2Q _W Q CD � CC in z 0 J U W F-- SCALE: 1/8" =1 ' DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE:05/20/2008 BACKROUND PLAN PROVIDED BY: \OB NUMBER: ( SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FA -04 fq't • 1.0 (E)±9'- 10" FV. (E) MALL CONCOURSE ,(E)±10'-0" r.Fv RO4 • . 100 : iII dhistais 1. RESTAR004 iwxp (N) intri rim!, mi rxr low I I wzd "Aralliiiiigralli mom- 11111111111111111M1111111 111.11 Arl- EAIE 44 4 ▪ F\/ 4 0 a 40-8'-o" nN) GWB 1E2, Oki E ±1:1781. pp (E) •HALLWAY 106 -- • (E) ELEC • TROOM CLOSET 105. : REFLECTED CEIL NG PLAN, 24' 0 6' 12' 1 /8" =1'-O" Design per NFPA 13 — Ordinary Hazard Group 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions 0 2, 0 2 — Relocate Reliable Model 056 QR 165° Concealed Pendent 1/2 x 1/2 o 1 — Relocate pendent to Globe Model GL5601 QR Brass 155° upright 1/2 x % O Without Comments O As Noted in Red Per The Attached Letter. These plans have been reviewed by The Tukwila Fire PreventiOn• Bureau for conformance.Mth current City • standards, Acceptance is subject to errors and . • omissions -which do not authorize violations of adopted • -;•:andards and ordinances, The responsibility for the ..,:idequacy of design rests totally with the designer.- Additions, deletions evisions to these drawings after .this date will void thif: 'acceptance and require a resubmit -lei of revlSed•OraWings for subsequent approval. Final acceptance is subject to. Held test and Inspection by The -Tukwila Fire Prevention Bureau.. 'Date: 117 -- By:- FlexHeac1 Sprinkler Drop TUKWILA FIRE DEPARTMENT Please call 206-575-1407 and give this Fire Permit No. /7-S-/72-/ and exactddress for shut- • down or restoration approval. NCorrugated stainless steel hose with stairilesS steel brat • .. •• avaAble in 2', & 6' legnths , • • • Z*1 Multi -Port Bracket • • . • •• .Adjustable Hub • . . •. • • •.•.•.. q19 FLEXHEASI . . . • F.lexhebd omnieycial Ceiling Unit: • T -bar belling Installation • ' ' Model #2024,2036,2048,60,2672 TEN pommegortm PIE PROTUOT1ON John J. Abei • 97010591-03 lave! S. • ClOWri Rio Pict:Non, OApWta.,P044LL 2•Firt•-"---01 • WWWWW000Milieforaw.,,,,mosememo A \11- SPACE LOCATION SECOND FLOOR (NOT TO SCALE) CROWN • FIRE PROTECTION •INCORPORATED P.O. BOX 12113 • MILL CREEK, WASHINGTON 98082-0113 . PH. (425) 481-7669 Safari • zY NA • Tukwila WA DATE: ei .1.17 DRAWN: (5-1 PAID SEP 1i2 TUKWILA • SCALE: oc –2<T 2876 SHELL SPACE General Notes VICINITY MAP (Suite#2876) SCALE: NTS 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. EAST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE \27/ tVe 12'-0" A.F.F —12'-0" A.F.F —12'-0" A.F.F Remote Area ESP Fad u GG A 3.6% ffi DN 1Y x 1-,89. DN 1% 1 reniBrei tre ® set t cl eizel en en t3 1 tus tt a tris mra ®' ON17.x1-BY: .�; l'A x 1-'/. 0 ,t( —Existing Main ZONE T3 12'-0" A.F.F A.F.F- 011'/ x 0 ,u43\* 6vr;` ixn� iw Ordinary Group II.0.20gpm/ftZ for 980.00ft2 \27i �28� FIRE SPRINKLER SYSTEM 1/8"-1'-0" 12'-0" A.F.F 15'-0" A.F.F .TYPICAL FLEXABLE SPRINKLER CONNECTION:: FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER, BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE 2876 SHELL SPACE Remote Area: Retail # 637 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM /Ft' for 980.00 Ft' SPRINKLER Reliable F1 FR Semi-Rec ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION*: STATIC 140 RESIDUAL 20 FLOW 10900 PSI PSI GPM AT BASE OF RISER, SYSTEM REQUIRES: 283.21 GPM C°J 71.39 PSI • At time of Design 12'- 0" CLG. = 37.00% AREA REDUCTION ////////////// SWIVEL SWIVEL SWAY BRACE FITTING 318" KWIK BOLT (2114' EMBED LENGTH) BRACE PIPE • FIG.1000 "FAST CLAMP" SWAY BRACE ATTACHMENT LINE PIPE LATERAL LINE RESTRAINTS NON•THREADED BRACE PIPE FIG.4A PIPE CLAMP FOR SWAY BRACE FIG. 909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT LATERAL BRANCHLINE RESTRAINT 319• KWIK BOLT (2 114' EMBED LENGTH) BRACE PIPE STCa�o NON•THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAIN T NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III HILTI Kwik Bok II +� \ / Drilled Anchor � �- • Cut Rod Lgth Rounded to Nearest Inch Rod Coupling All Thread Rod Pipe Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan . Note on Plan: Hanger Number and A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE Vanilla Shells O Swinerton Builders CONTRACTOR: SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE R3615 34 5.6 Pendent Chrome 155°F Reliable F1 FR Semi-Rec APPROVAL: City of Tukwila HYDRAULIC REFERENCE POINT R5415 14 5.6 Pendent Brass 155°F G4A Concealed CONT. NO.: KS0407 Total = 48 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 06/19/08 It Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/DECATUR/DENVER/DULUTH/HOUSTON /KANSAS CITY LAS VEGAS /MINNEAPOLIS / PHOENIX / PORTLAND / RAPID CITY / ST. PAUL/SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 Vanilla Shells Southcenter Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SHEET. FP -1 OF 1 Z-76 .I 2876 SHELL SPACE —VICINITY- Ml P-(- a ite# 287-G)-- __..__ __ SCALE: NTS General Notes 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze, protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprtn-kler system to remain. Western States Fire Protection will modify the existing system only jn the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. EAST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE SYMBOL LEGEND REVISIONS is 1 0 0 ON1'%g1'4'/= cm al— .--E ZONEg 3ain V 1'/: x Remote Area ---r•' 414)- +0 Without Comments As Noted In Red Per The Attached Letter 1s !nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance witti current city standards. Acceptance is subiect to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibi;ity for the adequacy of design rests totally with the designer. Additions, deletions or revisions t'o these drawings atter this date will void thk3 acceptance and will require a resubmittal of revised drawings for subsequent approval. 1 Final acceptance is subject to field test and inspection bV The Tukwila Fire Prevention Bureau. Date: G'11--� By: sal fATIECE j •- Ordinary Group II'0.20gpm/ft2 for 980.00ft2 'geld stamps must b inspected Fore pit . is hung. not paint piping prior to hydrostatic test approval. FUKWILA FIRE DEPARTNIE141 Please call: 575.4407 and give this job ND.c73-S-T and exact address for shut, -own or restoration ao i. ESP_BI.NKLER SYSTEM 11 11 Sprinkler Legend _1_3-5_7-9— 11 _ E3.) FILE rffiPY :;.TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD MOUNTING BRACKET • PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID --SPRINKLER HEAD- CEILING TILE FLE;.IIEAD DETAIL NOT TO SCALE 2876 SHELL SPACE Remote Area: Retail # 637 CALCULATION DESIGN CRITERIA STANDARD NFPA #13.2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130. . Ft' DENSITY .20 GPM ! FN for 980.00 . Ft= SPRINKLER Reliable F1 FR Semi-Rec ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 283.21 GPM 0) 71.39 PSI At time of Design 12'- 0" CLC. m 37.00% AREA REDUCTION //////////// // FIG. B08 SWIVEL SWAY BRACE FITTING 3/B' KWIK BOLT 121/4' EMBED LENGTH) BRACE PIPE FIG. 1DOD f J "FAST CLAMP" SWAY BRACE ATTACHMENT LINE PIPE O LATERAL LINE RESTRAINTS 70g0 HON -THREADED BRACE PIPE no. 4A PIPE CLAMP FOR SWAY BRACE 3t8' KWIK BOLT (2 1/4' EMBED LENGTH) FIG.1309 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT LATERAL BRANCHLINE RESTRAINT 1C6.nfl NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III HILTI Kwik Bolt II Drilled Anchor -- \ i �V Rod Coupling Q Cut Rod Lgth Rounded to Nearest Inch All Thread Rodq. Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE CI) t, a co w Adam Kantner LL V) N 0 VICINITY MA. DETAIL_.___ TC) Re At Swinerton Builders CONTRI.CTO 2 -WAY EARTHQUAKE BRACE N0. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE R3615 34 5.6 HYDRAULIC REFERENCE POINT R5415 14 5.6 Pendent Pendent 111 z Chrome 155°F Reliable F1FR Semi-Rec APPROVAL: City of Tukwila Brass 155°F G4A Concealed CONT. NO.: KS0407 Total = 48 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE: 06/02/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105- REDMOND, WA - 98052 Lic. # WESTESF138QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/DECATUR /DENVER /DULUTH / HOUSTON /KANSAS CITY LAS VEGAS /MINVEAPOLIS /PHOENIX/PORTLAND/ RAPID CITY/ ST. PAUL /SALT LAKE CITY/ SEATTLE Phone: 425-881-0100 Fax 425-881-3030 Vanilla Shells Southcenter Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM r -Lt 08 Tukwila Fire rpik .24,6 2, SHEET FP -1 OF 1 2876 SOUTHCENTER MALL ASSOCIATED PERMITS 19-F-251 08-F-268 19-S-247 17-S-174 08-S-312 Ottwirt44 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Ci Z O Z y 7- o o t o Site Address: 2 70 W es a 1 mat Tenant Name: C Ac 0\ C Property Owner's Name: LA.) e5.k- c t e k A, Mailing Address: f O 6 0' ( (50411. Suite Number: 24110 Floor: 2. New Tenant? ❑ - Yes ❑ - No Cqt- \5 b0.A CONTACT PERSON -if there are questions about the submittal. Name: 1esS\C& e.btni3D City Company Name: C. CO L" -IN Y 1re_ (('0 i n i1 Day Telephone: �N c CA 1Z°13 State Zip L -t z 5 L(I 17(0 !o 9 Mailing Address: Po et -3Y (Z t 13 I 1 1 1 t( C A, go City State Zip E-mail Address: , Q S) C(r) i , C m Fax Number: LA 2 $ Y $ to Contractor's City of Tukwila NICET III number: Business License number: v 5- O 9 g S•gt Z. Total number of new/relocated devices or sprinkler heads: 3 Valuation of Project (contractor's bid price): $ 15-0 0 Scope of Work (please provide detailed information): R_ `6 (,Gl � 5 pS r Icen 0.n 1me(-ot,e(\--tkA- WesA-cek fln al PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGEN Signature: Print Name: Day Telephone: Plan Permit App.doc Date: q/ i /17 L/Z5562I40 8/22/14 TFD FP Form 8 -iN\-\N\ \e_A- 4.4"044 SITE LOCATION Site Address: CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Tenant Name:' C\Y \ Property Owner's Name:\ CA, D Mailing Address \k -VC) CONTACT PERSON -if there are questions about the submittal. Name %6( C4) j \ Company Name: aq0CACs u1 S&L\ King Co. Assessor's Tax No.RACAW1 B t l V Suite Number: ,gVi D Floor: New Tenant? Yes ❑ - No \C4 --`gyp\ utc\thc01A C\RLA� City State Zip Mailing Address: \ 4' \`*-kqP _ J E-mail Address Day Telephon O b'7) City State Zip Fax Number: ontractor's City of Tukwila NICET III number: Business License number:�S (i1 Total number of new/relocated devices or sprinkler heads: i 02 Valuation of Project (contractor's bid price): $ (pi C)L; l Scope of Work (please provide detailed information):"( cx\o'(« t)\-\floi NI P \S`(e) * (u(kulu1 alb4 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER OR AUTHORIZED AGENT: Signature: Print Name: i!\ Date: `DI3 t tC1 TCUC (-y V\ Day Telephone00 i o) 1 '— 34-(c Plan Permit App.doc 8/22/14 TFD FP Form 8 4.4w4v SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 /2-» FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be acted for plan review. **PLEASE PRINT"* ,� t King Co_ Assessor's Tax No.: Site Address: 2:87u �o I ! ^ee .n rTer Man Tenant Name: Soco.x,1 Property Owner's Name: VieSN'S'A-e(\,fS0C Mailing Address: City State Zap CONTACT PERSON -if there are }c�questions aboutbthe submittal Name: Cdr��r�'e, lJ o1�► r�J� Day Telephone: /vj'L/S1'71a.{Q,9 Company Name: C)( •DY\ lr VY7Sic-eCti Mailing Address: T i 2 \ 111 �'.--e-; City State Zip E-mail Address: - �. i ** I • . • Fax Number Contractor's City Tukwila NICET III number: • t ti` q)• CG Busies License number: Suite Number Floor. New Taunt? D - Yes 0 - No Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 15O•C° ��,,,, Scope of Work (please provide detailed information): Acd c2) heads s PERMIT APPLICATION NOTES Value of Construction — In all cases, a vahne of construction amount should be entered by the applicant This figure wall be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER ORAUTHOW ED AGENT: Signature: (( Print Name: JCZiC 7 4>ns6r Play Permit App.doc */22114 Date: %2/5119 Day Telephone: q2s.zieri7e069 TED FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Vanilla Box 2876 Southcenter Mall Permit No.: 08-S-312 Date: June 12, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • These conditions apply to any sprinkler piping exposed as necessary to accomplish the permitted scope of work. All references are NFPA 13, 2007 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Safari 2876 Southcenter Mall Permit No.: 19-S-247 Date: December 27, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe. Section 18.5.5. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions. Section 18.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line. Section 18.5.6. • Provide lateral and longitudinal bracing for changes in pipe direction per section 18.5.7. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement. Section 18.6. • Restraints for branch lines shall be at intervals per table 18.6.4 (a)(b) and section 18.6 and restrain sprig ups greater than 4'. Section 18.6.6. • Comply with ASCE 7-05. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • Weld stamps shall be inspected on the ground, before the pipe is hung. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2019 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Safari 2876 Southcenter Mall Permit No.: 17-S-174 Date: September 19, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. • Qi ©M.E.P.CAD, Inc. 4111AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:11 PM Page 1 Hydraulic Summary ` Job Number: KS0407 Report Description: Ordinary Group II Job Job Number Design Engineer KS0407 Adam Kanter Job Name State Certification/License Number Vanilla Shells 2876 WESTESF136QF Address 1 AHJ Southcenter Mall City of Tukwila Address 2 Job Srte Southcenter Mall City State Zip Code Drawing Name Tukwila Wa 98188 FP-1.cad System Remote Area(s) Most Demanding Sprinkler Data Occupancy 5.6 K -Factor 26.00 at 21.556 . Ordinary Group II Hose Allowance At Source Density Area of Application 250.00 0.20gpm/ft2 980.00ft2 (Actual 980.02ft2) Additional Hose Supplies ' Number Of Spnnklers Calculated Coverage Per Sprinkler Node Flow(gpm) 10 130.00ft2 Total Hose Streams 250.00 II , System Flow Demand Total Water Required (Including Hose Allowance) - , ', 61 283.21 533.21 r 'y Maximum Pressure Unbalance In Loops~ ''. 0.000 l_....\V_,Jilii:�i Maximum Velocity Above Ground ' --.. v 18.01 between nodes 176 and 216 liOr Maximum Velocity Under Ground �s 1.07 between nodes 1 and 434 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 2109.51 gal 1.22ft' Supplies Hose Flow Static Residual Flow Available Total Demand i Required ' Safety Margin Node (gpm) (psi) (psi) (gpm) (psi) (gpm) (psi) (psi) 1 250.00 140.000 20.000 10900.00 139.548 533.21 74.845 64.704 Contractor Contractor Number Contact Name Contact Trtle KS0407 Adam Kantner Project Manager Contractor Name Phone Extension Western States Fire Protection 425.881.0100 Address 1 FAX 7102 180th Ave Ne, Suite A-105 485.736.9032 Address 2 E-mail City State Zip Code Web -Site Redmond WA 98052 Qi ©M.E.P.CAD, Inc. 4111AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:11 PM Page 1 r Summary Of Outflowing Devices Job Number: KS0407 Report Description: Ordinary Group II lye ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:15PM Page 2 Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) Sprinkler 110 30.09 26.00 5.6 28.871 Sprinkler 109 29.62 26.00 5.6 27.969 Sprinkler 108 29.16 26.00 5.6 27.119 Sprinkler 106 28.73 26.00 5.6 26.319 Sprinkler 107 28.73 26.00 5.6 26.321 Sprinkler 105 28.32 26.00 5.6 25.567 Sprinkler 104 28.12 26.00 5.6 25.222 c;:. Sprinkler 101 26.00 26.00 5.6 21.556 Sprinkler 102 26.32 26.00 5.6 22.087 Sprinkler 103 28.12 26.00 5.6 25.221 c' Most Demanding Sprinkler Data lye ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:15PM Page 2 Node Analysis Job Number: KS0407 Report Description: Ordinary Group II Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 176 17-6 • 2P0(8-0) 45.239 177 17-6 2P0(8-0) 45.174 178 17-6 2P0(8-0) 45.164 216 15-6 P0(5-0) 37.256 218 15-6 P0(5-0) 37.424 239 15-6 P0(5-0) 34.948 241 15-6 P0(5-0) 35.174 257 15-6 P0(5-0) 33.896 259 15-6 P0(5-0) 34.149 278 15-6 PO(5-0) 40.609 286 15-6 E(2-0) 40.545 288 15-6 E(2-0) 33.883 294 15-6 E(2-0) 33.606 309. 15-0 fEE(3-5) 56.412 310 16-1 fEE(3-5) 56.102 312 14-0 fE(6-9%) 57.983 313 16-1 fE(6-9'/2) 56.781 434 3-10% BFP(-4.500) 71.396 459 1-11 P0(37-8%) 67.698 463 14-0 fE(10-0) 62.211 474 1-11 LtE(16-0) 67.712 110 12-0 Spr(-28.871) 28.871 30.09 109 12-0 Spr(-27.969) 27.969 ' 29.62 108 ' 12-0 Spr(-27.119) 27.119 29.16 106 12-0 Spr(-26.319) 26.319 28.73 107 12-0 Spr(-26.321) 26.321 28.73 105 I 12-0 Spr(-25.567) 25.567 28.32 104 15-0 Spr(-25.222) 25.222 28.12 101 15-0 Spr(-21.556) 21.556 26.00 102 15-0 Spr(-22.087) 22.087 26.32 103 15-0 Spr(-25.221) 25.221 28.12 1 , -4-0 S 74.845 283.21 ©M.E.P.CAD, Inc. 401 AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:18PM Page 3 49B Hydraulic Analysis Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Length Summary Length Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Eq. Total v Route 1 DR 1.049 Q=26.00 9.65 C=120 0.211435 51-3 Pf 12.531 101 15-0 q=26.00 K=5.6 21.556 Spr(-21.556) 8-0 Pe -0.204 288 15-6 33.883 4E(2-0) 59-3 Pv BL 1.610 0=26.00 4.10 C=120 0.026249 10-1 Pf 0.265 288 15-6 33.883 Pe 259 15-6 34.149 10-1 Pv BL 1.610 0=54.32 8.56 C=120 0.102571 10-0 Pf 1.026 259 15-6 34.149 Pe 241 15-6 35.174 10-0 Pv BL 1.610 0=83.04 13.09 C=120 0.224978 10-0 Pf 2.250 241 15-6 35.174 Pe 218 15-6 37.424 10-0 Pv BL 1.610 0=112.66 17.75 C=120 0.395541 9-9% Pf 8.617 218 15-6 37.424 12-0 Pe -0.867 177 17-6 45.174 2LtE(2-0), PO(8-0) 21-91/2 Pv CM 4.260 Q=168.91 3.80 C=120 0.007321 9-0 Pf 0.066 177 17-6 45.174 Pe 176 17-6 45.239 9-0 Pv CM 4.260 Q=283.21 6.37 C=120 0.019047 298-5'/2 Pf 10.089 176 17-6 45.239 73-9 Pe 1.084 309 15-0 56.412 2E(13-2), 2cplg(-1.500), 4Ee2(5-3), 372-2% Pv PO(26-4) RN 4.260 Q=283.21 6.37 C=120 0.019047 1-6Y2 Pf 0.159 309 15-0 56.412 fEE(3-5) 6-10 Pe -0.470 310 16-1 56.102 fEE(3-5) 8-4% Pv CM 4.260 Q=283.21 6.37 C=120 0.019047 35-8 Pf 0.679 310 16-1 56.102 Pe -0.000 313 16-1 56.781 35-8 Pv RN 4.260 0=283.21 6.37 C=120 0.019047 2-1 Pf 0.299 313 16-1 56.781 fE(6-9%) 13-7, Pe 0.903 312 14-0 57.983 fE(6-9%) 15-8 Pv CM 4.260 0=283.21 6.37 C=120 0.019047 205-2 Pf 4.228 312 14-0 57.983 16-9% Pe 0.000 463 14-0 62.211 fE(6-9%), fE(10-0) 221-11% Pv FM 6.357 0=283.21 2.86 C=120 0.002712 11-1% Pf 0.252 463 14-0 62.211 81-8% Pe 5.235 459 1-11 67.698 CV(40-3), GV(3-9Y2), PO(37-81/2) 92-10'', Pv FM 8.329 0=283.21 1.67 C=120 0.000727 3-7 Pf 0.014 459 1-11 _ 67.698 16-0 Pe -0.000 474 1-11 67.712 LtE(16-0) 19-7 Pv FM 10.420 0=283.21 1.07 C=120 0.000244 26-5% Pf 4.527 474 1-11 67.712 83-0 Pe -0.842 434 3-10% 71.396 4LtE(16-0), BV(19-0), BFP(-4.500) 109-5% Pv UG 10.400 0=283.21 1.07 C=140 0.000185 109-2 Pf 0.041 434 3-10% 71.396 111-7 Pe 3.407 1 -4-0 74.845 E(35-1), 3LtE(25-6), S 220-9% Pv Route 2 DR 1.049 0=26.32 9.77 C=120 0.216244 48-3 Pf 11.727 102 15-0 q=26.32 K=5.6 22.087 Spr(-22.087) 6-0 Pe -0.208 294 15-6 33.606 3E(2-0) 54-3 Pv BL 1.610 Q=26.32 4.15 C=120 0.026846 10-10 Pf 0.290 294 15-6 33.606 Pe 257 15-6 33.896 10-10 Pv BL 1.610 0=55.05 8.68 C=120 0.105145 10-0 Pf 1.051 257 15-6 33.896 Pe 239 15-6 34.948 10-0 Pv BL 1.610 0=84.21 13.27 C=120 0.230856 10-0 Pf 2.309 239 15-6 34.948 Pe 216 15-6 37.256 10-0 Pv BL 1.610 Q=114.30 18.01 C=120 0.406256 9-9'/2 Pf 8.850 216 15-6 37.256 12-0 Pe -0.867 176 17-6 45.239 2LtE(2-0), P0(8-0) 21-9% Pv .i Route 3 DR 1.049 0=28.12 10.44 C=120 0.244485 53-6 Pf 15.528 103 15-0 q=28.12 K=5.6 25.221 Spr(-25.221) 10-0 Pe -0.204 286 15-6 40.545 5E(2-0) 63-6 Pv BL 1.610 0=28.12 4.43 C=120 0.030352 2-1% Pf 0.065 286 15-6 40.545 Pe 278 15-6 40.609 2-11..4Pv BL 1.610 0=56.25 8.86 C=120 0.109422 37-61,4 Pf 5.421 278 15-6 . 40.609 12-0 Pe -0.867 178 17-6 45.164 2LtE(2-0), P0(8-0) 49-6' Pv (SM ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:21 PM Page 4 Hydraulic Analysis Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Eq. Length Summary Total Length Downstream Elevation Discharge K -Factor Upstream Pt Pn Fittings CM 4.260 Q=56.25 1.27 C=120 0.000957 10-6 Pf 0.010 178 17-6 177 17-6 45.164 45.174 Pe 10-6 Pv Route 4 DR 1.049 0=28.12 10.44 C=120 0.244498 52-9 Pf 15.591 -0.204 104 15-0 q=28.12 K=5.6 278 15-6 25.222 40.609 Spr(-25.222) 3E(2-0), PO(5-0) 11-0 Pe 63-9 Pv v Route 5 DR 1.049 Q=28.32 10.51 C=120 0.247588 29-9 Pf 10.087 -1.506 105 12-0 q=28.32 K=5.6 259 15-6 25.567 34.149 Spr(-25.567) 3E(2-0), PO(5-0) 11-0 Pe 40-9 Pv ill Route 6 DR 1.049 . 0=28.73 10.66 C=120 0.254314 29-9 Pf 10.361 -1.506 106 12-0 q=28.73 K=5.6 241 15-6 26.319 35.174 Spr(-26.319) 3E(2-0), PO(5-0) 11-0 Pe 40-9 Pv Route 7 DR 1.049 0=28.73 10.67 C=120 0.254337 26-8% Pf 9.081 -1.506 107 12-0 q=28.73 K=5.6 257 15-6 26.321 33.896 Spr(-26.321) 2E(2-0), P0(5-0) 9-0 Pe 35-8% Pv 4 Route 8 DR 1.049 Q=29.16 10.83 C=120 0.261455 26-8% Pf 9-0 Pe 35-8% Pv 9.335 -1.506 108 12-0 q=29.16 K=5.6 239 15-6 27.119 34.948 Spr(-27.119) 2E(2-0), PO(5-0) Route 9 DR 1.049 0=29.62 10.99 C=120 0.269030 29-9 Pf 11-0 Pe 40-9 Pv 10.961 -1.506 109 12-0 q=29.62 K=5.6 218 15-6 27.969 37.424 Spr(-27.969) 3E(2-0), PO(5-0) v Route 10 DR 1.049 0=30.09 11.17 C=120 0.277043 26-8'4 Pf 9-0 Pe 35-8% Pv 9.892 -1.506 110 12-0 q=30.09 K=5.6 216 15-6 28.871 37.256 Spr(-28.871) 2E(2-0), PO(5-0) Equivalent Pipe Lengths of Valves and Fittings (C=120 only) ` C Value Multiplier Actual Inside Diameter 4.87 ) Value Of C 100 Multiplying Factor 0.713 130 1.16 140 1.33 150 1.51 = Factor ( Schedule 40 Steel Pipe Inside Diameter © M.E.P.CAD, Inc. 4111 AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:21 PM Page 5 1111 Hydraulic Analysis Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Elevation Upstream Discharge K -Factor Pt Pn Fittings Length Pressure Eq. Length Summary Total Length Pipe Type Legend Units Legend Fittings Legend AO BL CM DN DR DY FM FR MS OR RN SP ST UG Arm -Over Branch Line Cross Main Drain Drop Dynamic Feed Main Feed Riser Miscellaneous Outrigger Riser Nipple Sprig Stand Pipe Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111/40 Elbow Ee2 221/z Elbow f Flow Device FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Tum 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD, Inc. j�AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:21 PM Page 6 11 I Hydraulic Graph 1 Job Number: KS0407 Report Description: Ordinary Group II Supply at Node 1 150 Static Pressure 140.000 135 120 105 90 .N a `i with hose streams 75 N CA 2 a` ,533.21 -283.21 @ 74.845 60 45 System demand curve 30 10900.00 @ 20.00011 15 w 111111111 111 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111111111 111111111 0 0100 01002200 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.548 @ 533.21 System Demand 283.21 @ 74.845 System Demand (Including Hose Allowance) 533.21 @ 74.845 f[ ©M.E.P.CAD, Inc. AutoSPRINKO VR5 v5.2.6 06/02/2008 3:08:30PM Page 7 Flow Diagram (Top View) Job Number: KS0407 Report Description: Ordinary Group 11 ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/02/2008 3:08:34PM Page 8 SOUTH CENTER MALL SAFARI FIRE ALARM SYSTEM ADDITION TU ILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET # SHEET TITLE FA -01 SYSTEfv If\FO V4ATIO\ FA -02 TYPICAL WHI\G A\ 3 v OU\TI\G DETAILS FA -03 FLO0FRE ALARM PLA\ /CALCULATIONS SI\GLE LI\E DIAGAIV SCOPE OF WORK ADD 4 NEW CEILING MOUNT SPEAKER/STROBE, ADD THREE(3) NEW STROBE, AND INSTALL INTELLIGENT INITIATING DEVICE TO SHUTDOWN MUSIC AND DUCT DETECTOR INTERFACE MODULE TO AN EXISTING FIRE ALARM SYSTEM. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NEPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 4 1 1 3 1 2 E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT [5 FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW (1/2W - 70.7V) SIEMENS 4S BOX CEILING TSM DUCT DETECTOR TEST SWITCH (NEW) TSM- 1 SIEMENS 4S DEEP BOX VERIFY IN FIELD ADDRESSABLE SMOKE DETECTOR (NEW) HFP-11 W./ DB -11 BASE SIEMENS EXISTING CEILING FIRE ALARM STROBE (NEW) ZR -MC -CW SIEMENS EXISTING CEILING DUCT HOUSING O WITH DETECTOR (NEW) FDBZ492-HR W/ HFP-11 DET SIEMENS DUCT HOUSING VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY (NEW) HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD DE (EX ST NG) NCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD E EXISTING DEVICE N/A N/A N/A N/A A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT • APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A 'I( Without Comments a As Noted in Red 0 Per The Attached Letter hese plans have been reviewed by tre Tukwila Fire ,ention Bureau for conformance current City ldards. Acceptance is subject to eriors and ,.;sions which do not: authorize viol t orfs of adopted dards and ordinances.. The respor+sIbiiity for the -.luacy of design rests totally with the designer, ditions, deletions or revisions to theta drawings after date will void t.thiis acceptance and wi'.i require a resubmittal of revised drawings for subsequent approval, Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: / 3° -15 By: AN"-‘ J Fire Permit Number To schedule. inspections call 206-575-4407 REVIEWED BY: ANTHONY MEDAWAR, CET NICET LEVEL III, FIRE ALARM SYSTEMS NICET ID: 144058 VALID THROUGH: FEBRUARY 1, 2023 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved rs0 0-5 Cr z O z Lu > QIlad Citt- FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I WIRE DESIGNATION 0 W SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C D S S' V V' I POWER SUPPLY SYNC TWISTED PAIR WITH SHIELD #14 FPLP DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP SPEAKER CIRCUIT - FEED TWISTED PAIR #16 FPLP SPEAKER CIRCUIT - RETURN TWISTED PAIR #16 FPLP INITIATING CIRCUIT TWO #18 FPLP RECORD DRAWINGS CONDUIT FILL CHART DATE NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS TWO 600V #12 AWG THHN/THWN .244 O.D. TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. TWO CONDUCTOR 300V #18 AWG FPL 1W CABLE .156 O.D. CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. AREA .0467 .0346 .0191 SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NEPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 4 1 1 3 1 2 E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT [5 FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW (1/2W - 70.7V) SIEMENS 4S BOX CEILING TSM DUCT DETECTOR TEST SWITCH (NEW) TSM- 1 SIEMENS 4S DEEP BOX VERIFY IN FIELD ADDRESSABLE SMOKE DETECTOR (NEW) HFP-11 W./ DB -11 BASE SIEMENS EXISTING CEILING FIRE ALARM STROBE (NEW) ZR -MC -CW SIEMENS EXISTING CEILING DUCT HOUSING O WITH DETECTOR (NEW) FDBZ492-HR W/ HFP-11 DET SIEMENS DUCT HOUSING VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY (NEW) HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD DE (EX ST NG) NCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD E EXISTING DEVICE N/A N/A N/A N/A A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT • APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A 'I( Without Comments a As Noted in Red 0 Per The Attached Letter hese plans have been reviewed by tre Tukwila Fire ,ention Bureau for conformance current City ldards. Acceptance is subject to eriors and ,.;sions which do not: authorize viol t orfs of adopted dards and ordinances.. The respor+sIbiiity for the -.luacy of design rests totally with the designer, ditions, deletions or revisions to theta drawings after date will void t.thiis acceptance and wi'.i require a resubmittal of revised drawings for subsequent approval, Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: / 3° -15 By: AN"-‘ J Fire Permit Number To schedule. inspections call 206-575-4407 REVIEWED BY: ANTHONY MEDAWAR, CET NICET LEVEL III, FIRE ALARM SYSTEMS NICET ID: 144058 VALID THROUGH: FEBRUARY 1, 2023 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved rs0 0-5 Cr z O z Lu > QIlad Citt- FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I 0 Mm rr 0 W DESCRIPTION SHOP DRAWINGS RECORD DRAWINGS DATE 0) 11/04/19 0 N N rn 0 0 ct uJ N (I) CALE: NOT TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 12/20/19 BACKROUND PLAN PROVIDED BY: \OB NUMBER:49800-1) SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL HARD LID \� CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE 4" SQUARE BOX CEILING MOUNTED SPEAKER/STROBE (OR STROBE ONLY) SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM PREVIOUS ADDRESSABLE( DEVICE 2 SWITCH INPUT MUSIC SHUTDOWN 00 22 FDBZ492-HR TB1 NO COM NC 2 TO FAN SHUTDOWN 22 0 -®I 2 00 a HTRI-R 0 NO e COM NC 0 0 9/2) 00 EOLR --vv 470 0 0 SWITCH + - INPUT LED TSM -1 e ADDRESSABLE DEVICE TO NEXT 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL FROM EXISTING TENANT J -BOX FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) SPEA (+) <ER fl (-) BI 3 4 5 0 0 e HTRI-R 0 NO e COM ® NC 0 0 u (+) ST (- REEE (+) ST RE3E SPEA (+) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE REVIEWED BY: ANTHONY MEDAWAR, CET NICET LEVEL III, FIRE ALARM SYSTEMS NICET ID: 144058 VALID THROUGH: FEBRUARY 1, 2023 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m CC 0 m IY DESCRIPTION SHOP DRAWINGS RECORD DRAWINGS DATE 0) 11/04/19 0 cV N SCALE: NOT TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 1 2/20/1 9 BACKROUND PLAN PROVIDED BY: �0B NUMBER: 49800-1,i 1 SHEET FA -02 VORK A.6.1 CA) STORAGE 203 -S1-4 11OCd V1-1 1 /2W EOL S1-7 Si 75Cd V1-4 1 /2W T- .(4) CO PARTY ROOM PLAY AREA CG AREA OF WORK NEW ADDITIONAL DEVICES SPEAKER/STROBES S1-5 75Cd V1-2 1/2W CHECK-IN 117.1%, • • • 111161111111 MOM IMMO Mitilll 000 FLOOR FIRE ALARM PLAN SCALE: 3/16" = 1'-0" V TSM SHUTDOWN MUSIC D I c IHT-R� Notification Appliance Circuit Detail PROJECT: 1 SOUTH CENTER MALL SAFARI Panel: ; EXISTING(TENANT) POWER SUPPLY Wire. Resistance 2.58 SET MC-CW(aA15Cd S ET111I C-CW6,30 SET MC-CW@75Cd SET-MC-CWrvP„955Cd `ZR -M C-CWp,15Cd -enc Iocd ZR -M C-CWA75Cd ZR -M C-CW95Cd 69' 111, 200! 264 69' 207' 800 111 200 TOTAL m A= Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage ... , 1007 14 (WL*2)*(Rift (Total Cct Load (E=I*R) .24-_E 1.11 .01 1.12 22.88 SPEAKER CIRCUIT ADD-ONS PROJECT `SOUTH CENTER MALL SAFARI Panel: EXISTING XLSV FACP Date: December 20, 2019 Wire Resistance 2.58 CURRENT TOTAL= 28.8 0 '70.7V70.7V1/8-WATT 70.7V 1/4 -WATT 70.7V 1/2 -WATT p; 707V1 -WATT, DEVICES= '4 7.2 28.8 14:4 0:.;. TOTAL m A= ' 2 8.8 Total Wire Resistance ( R ) Total Device Load, ` Amps (1) Voltage Drop (E ) EOL Voltage 16 20.4 WL*2)*(Rift) (Total Cct Load '(E= 1 * R) (24, - E). 0.00 0.03 0.00 24.00 CALCULATIONS FROM EXISTING ) SPEAKER STROBE C v E EXISTING TENANT J -BOX S1-1 15Cd S1-2 15Cd S1-3 15Cd SINGLE LINE DIAGRAM NOT TO SCALE S1-4 75Cd V1-1 2W S TO NEXT DEVICES ) SPEAKER STROBE v6 S1-5 75Cd V1-2 2W S1-6 75Cd V1-3 2W S1-7 75Cd V1-4 1 2W L REQ IC NIC VALID BY: ANTHONY MEDAWAR, CET NICET LEVEL III, FIRE ALARM SYSTEMS NICET ID: 144058 VALID THROUGH: FEBRUARY 1, 2023 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 03 Ct DESCRIPTION SHOP DRAWINGS DATE 0) 0 N N z aaaa< O Q co 00 o frz < 0 2 cc 0 ▪ Z 1 - CO z = co0< re • I— D er wL1.1 CID ▪ N CC W J J 0 z CC aC LLI OC Li CC 0 0 u- �CALE:3/16"=1'-0" DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 12/20/19 BACKROUND PLAN PROVIDED BY: •JOB NUMBER:49800-1} SHEET FA -03 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ( WESTFIELD SUITE 2170 FIRE ALARM SYSTEM TUKWILA, WASHINGTON ( SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \UVI3ESHEET TITLE FA -01 SYSTEM INFO .MATIO\ FA -02 TYPICAL DETAILS - WRING A\D MOU \TI \ G FA -03 FRE ALARM SYSTEIv FLOG PLA\ FA -04 SYSTEM CALCULATIO\S GE \E�AL), .ISE, SITE PLAN WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIAT❑R TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE NCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL • BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT, AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF -NEPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD : DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED 'ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT.: 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS, USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 3 2 1 2 2 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD B a LINEAR BEAM SMOKE DETECTOR. PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE D DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING gL C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM STROBE (CEILING MOUNT) L❑ Q C FIRE ALARM STROBE (WALL MOUNT) FIRE ALARM SPEAKER (CEILING MOUNT) SET -MC -CW SIEMENS SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 4S DEEP BOX W/ 1-1/2" EXT. CEILING 80" A.F.F. TO BOTTOM SET -HMC -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING Y WP MR FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) MULTI -VOLTAGE CONTROL RELAY SET -W SET -S17 -WP MR -201 /C SIEMENS SIEMENS AIR PRODUCTS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. VERIFY IN MELD FA JBOX FIRE ALARM TERMINAL CABINET O JUNCTI❑N BOX F.B.O. F.B.O. F.B.O. a F.B.❑, N / A F.B.O. GCE TED UVithout Comments VER IFY IN IELD VERFY IN ilELD A.F.F, ABOVE FINISHED FLOOR N/A - K/A (] As Noted Inl N/A o Per The Attached Letter F.B,❑. FURNISHED BY OTHERS N/A i n 14lans have been revi d i by The Tukwila Firs/A Prevention Bureau for conformance with current city A comple N/A NOT APPLICABLE N/A st rds. Acceptance is 5 1 »A^t to errors and o Ions which do not autho� a violations of adopt iA stanaaras and oromances. The responsibility for the Fire De Certificat U.D.N. UNLESS OTHERWISE NOTED N/A ad'�,�Y of design rests_totall with the designer. Ade bens, deletions or reviskiAo these drawings atE1A this date will void this acceptance and wits require a to the comment Testinc WP WEATHERPROOF DEVICE N/A res1.9afflittal of revised drawiiv/sjorsubsequent apprcATIA Final accpptanee is cr,To field test and inspection by and C FailurE RED AS BUILT ADD OR CHANGE N/A kwila Fire,Preventio eau. 7 9 N/A r O Date: D By' in a Re termini r,RFEN AS BUILT N/A N/A N N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright TUKWILAFIR57D4407 Mall Please call: end give this job and r crownorexact restorationress oapP approval/ 2006 by Guardian Security Systems, r) FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS .\/ CO T < a) W 2Z WWO ZZ CO 2 ILu = NOTICE 0 cc i Q ed, Q = apartment Pre-test W w p e must be presenteE cc (1) S Inspector prior to ement of Acceptar of any Fire Alarm etection Systems. of test will result inspection Fee and Ition of the testing, E PAID 1 - 2008 Tukwila Fire zfrg/ Inc. All Rights Reserved UL ND LU Z 0 0 z CALE: 1 /8"=1 DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE:05/20/2008 BACKROUND PLAN PROVIDED BY: .OB NUMBER: SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE �+ STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR -C+ PREVI❑US ADDRESSABLE DEVICE - END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH O DUCT DETECTOR LOCATION GROUND -- =f% CV L() raj HTRI—R STATUS LED N.O. COM N.C. _--%- NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL ima SCA<E (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE_ DEVICE TO NEXT ADDRESSABLE DEVICE L - + NOTE 1: VOLTAGE MAX. - CURRENT MAX, - CONT. RES, MAX. - MAX, CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE- OUTLET SAMPLING---•\ TUBE INLET SAMPLING—\ TUBE \ AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE MUSIC �}-AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE{+)__ STOP IF LAST DEVICE {{-)-- FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE {-)-- RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) 27 VDC 3,5 riA DURING POLLING 10 OHMS 200 FT, (18 AWG) 0,02uF 0,04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC, TO GUARANTEE DETECTION. O J 1 0 0 1 TB1 5 0 0 0 0 23456 HCP TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE O ' END OF LINES DEVICE (3,6K 1/4W) SUPERVISED SWITCH GROUND r0 CV LO HTRI—D --STATUS LED 0 NOT USED FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE + DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0 0 {FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE POWER SUPPLY ('S' CABLE) END OF ' LINE DEVICE FROM . FACP 6..3,6K 1/4W) (VOICE CIRCUIT) O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABELBrAE(FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC 111 0 0 0 CI 01 II 0 PAD -3 0 0 00 O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 24K + NAC -4 NAC -3 NAC -2 NAC -1 ('V' CABLE) SUPERVISED 1 SWITCH 470 OHMS EOL TCM -1 0 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NUE u �.J (STROBE) SPEAKER (+) () ((- STROBE EARTH GROUND 0 --->(+)TO NEXT DEVICE OR 1 >(-) STOP IF LAST DEVICE (STR❑BE) SPEAKER (+) (—) 0 SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY R 80" A.F.F. O O 4S DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERPIIN TEMPERATU E: +32'F (0' C) TO 100' F 38 C) HUMIDITY: O-9 % RELATIVE HUMIDITY, NON -CONDENSING HFI' -11 SMOKE DETECTOR -3► FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) >- 1. DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICE*— ( ) DATA OUT (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID -\. CEILING --------SPEAKER SUPPORT TILE -- BRIDGE HARD LID -- 4' SQUARE DEEP BOX ,, WITH 1-1/2' EXTENSI❑N - CEILING MOUNTED N SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTION BOX----. MOUNTED ON \ CEILING FLEX \ JUNCTIDN BOX ---- MOUNTED AGAINST CEILING SUPPORT P / / / A O O 7g5 I TO NEXT DEVICE O O CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE=NONE of SUSPENDED ILLUMINATED CEILING DO \OT I\STA_L ADDRESSA LE N HAT DEVICES %INTI_ PREPROGRAMMED WIT DEVICES ADDRESS. NG Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS w DESCRIPTION SHOP DRAWINGS W a 00 0 0 N 0 N 0 0 z 0 OD OD CTJ ¢0) 1— w00 1) w= 2.i ?(!) 'Q .JQ�� W Wp LT cc u) F— _� W N D F- 23: DRAWN - J z F - z 3 0 0 z (I) a. 0 z E SCALE: 1 /8"=1 DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE:05/20/2008 BACKROUND PLAN PROVIDED BY: `OB NUMBER: SHEET FA -02 } IL -C 1' I Fri 23'- 2„ i r -`. r_� F \- 2s,2V D,I 2I SM D,I ' 2I s 2V 35'-2" 115 C NORTH El L 115 C SUITE 2110 WESTFIELD SOUTHCENTER MALL SCALE 118"=1' FLAG \ OTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATI❑N SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLATOR FIRE SUPPRESI❑N SYSTEM, FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT, DO NO INS AL_ ADDRESSABLE IIT DEVICES U\ IL PREPROGRAVMED W DEVICES ADDRESS. ATI N G Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved v W cc a 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 C/) Z O (1) W CC W C/) w J W REV. BY: EGH z O a_ E Cf)U w SHOP DRAWINGS 0 DATE 05/20/2008 2aa«< J O CO CO T 00; WO Iz E-0 w= ❑ <_0) J Q D� WwO LL 5 1-W° W CV D F- I SCALE:1/8"=1' DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 BACKROUND PLAN PROVIDED BY: .J..0B NUMBER: r SHEET FA-O3� `IfffTTfr NORTH SUITE 2110 WESTFIELD SOUTHCENTER MALL SCALE 1132°=1' S,2V S,2V 2S,2V 2S,2V 2S,2V b C 115 C 115 75 15 EOL -S1 15 EX FACP RISER DIAGRAM SYSTEM CALCULATIONS BATTERY SIZING CALCULATION Panel: 2170 SUITE 2170 SUITE 2170 FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations CURRENT TOTAL= 939 DATE CIRCUIT: S1 9 CCaCa QTY Current Load: Alarm Current Alarm Total Standby: Alarm: Voltage at EOL Current Load: Standby: Alarm: 64 0 Total Wire Resistance (R) 0.86 0 SET -MC @30CD 98 0 Device Type Qty Amps Total Amps Total Device Type Qty Amps 0.94 Total Amps Total 0 HFP-11 0.0022 0.0022 0.0023 2 SET-HMC-C@115CD 318 636 Voltage Drop ( E) AD2-P 0 2 0.0635 0.0635 0.064 0.128 Main System Board 1 0.03 0 0.03 0.030 0.030 HTR -R H TR I -D ICP -B6 3 0.009600 0.0096 0.021 0.063 SET -HMC @185CD SET -MC @15CD SET -MC @30C D SET -MC @75CD SET -MC @110CD SET HMC-C@115CD SET HMC-C@135CD SET HMC-C@185CD ZR -MC @15CD ZR -MC @30CD HCP 0.064 (20.4 - E) 2 0.001600 64 0.0035 0.098 0 Z -MC @30C D 98 0.005 1 0 0.175 0.175 0 DEVICES= 5 TOTAL mA= 939 0.233 265 19.5937.746) 939 2 0.318 0.636 Notification Appliance Circuit Detail 'PROJECT: WESTFIELD SOUTHCENTER MALL 0.318 Panel: 2170 Wire Resistance 2.58 0.0731 Amps 0.191 Amps 7.2 CIRCUIT 0.445 2 Device Type . Alarm Current Alarm Total 0.064 0.128 Voltage at EOL Standby Current Load: ■ 0.0731 Amps For 24 Hours = 1.754 Amp -hours 0.098 2.92 0 0 0 (WL*2)*(R/ft) 0 0.0015 0 Alarm Current Load: 0.191 Amps For 5 Minutes= 0.016 Amp -hours 0 0 0.03 Amps 0.969 Amps (Total Cct Load) 0 0 0 Voltage Drop (E) 0.02 0 0 0 25% Derating= 2.213 Amp -hours (E=I*R) Standby Current Load: 0 - 0.03 Amps 0 For 24 Hours = 0.720 Amp -hours EOL Voltage 20.38 0 0 0 (20.4-E) 0 0 . 0 Alarm Current Load: 0.969 Amps For 5 Minutes= 0.081 Amp -hours Total System Current Load: 4 2.213 Amp -hours 14 565 20.37900912 7.2 112VDC 25% Derating= 1.002 Amp -hours Battery Pair to be Used: [Amp -hours 7AH Total System Current Load: 1.002 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION Panel: 2170 Wire Resistance 1.62' Date: June 3, 2008 CURRENT TOTAL= 939 DATE CIRCUIT: S1 9 CCaCa QTY Device Type Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total SET -MC @15CD 64 0 Total Wire Resistance (R) 0.86 0 SET -MC @30CD 98 0 ( WL * 2 )* (R/ft) 1 SET -MC @75CD 175 175 Total Device Load, Amps (I) 0.94 0 SET -MC @11 OCD 233 0 (Total Cct Load) 2 SET-HMC-C@115CD 318 636 Voltage Drop ( E) 0.81 0 SET-HMC-C@177CD 445 0 (E= I * R) 0 SET -HMC @135CD 318 0 EOL Voltage 19.59 0 SET -HMC @185CD 445 0 (20.4 - E) 2 Z-MC@15CD 64 128 0 Z -MC @30C D 98 0 0 SET-MC-CW@110CD 233 0 DEVICES= 5 TOTAL mA= 939 12 265 19.5937.746) 939 Notification Appliance Circuit Detail 'PROJECT: WESTFIELD SOUTHCENTER MALL Panel: 2170 Wire Resistance 2.58 Date: June 2, 2008 CURRENT TOTAL 7.2 CIRCUIT SPEAKER CIRCUIT QTY Device Type . Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total ■ 4 70.7V 1/8 1.8 7.2 Total Wire Resistance (R) 2.92 0 0 0 (WL*2)*(R/ft) 0 0 0 Total Device Load, Amps (I) 0.01 0 0 0 (Total Cct Load) 0 0 0 Voltage Drop (E) 0.02 0 0 0 (E=I*R) 0 - 0 0 EOL Voltage 20.38 0 0 0 (20.4-E) 0 0 . 0 0 . 0 0 1 DEVICES= 4 TOTAL mA= 7.2 14 565 20.37900912 7.2 VOLTAGE DROP CALCULATION co 0 z_ W I - w 0 ui r` RELEASE/REVISIONS REV. BY: I EGH DESCRIPTION SHOP DRAWINGS DATE 05/20/2008 9 CCaCa W Cr - W O I` ao EE CO N ._,_i CO W § z < ~ W imp cc D ZZ Ci) V<2(1) = a V2Q _W Q CD iIcc inz U J U W SCALE: 1/8" =1 ' DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE:05/20/2008 BACKROUND PLAN PROVIDED BY: \OB NUMBER: ( SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FA -04 fq't • 1.0 (E)±9'- 10" FV. (E) MALL CONCOURSE ,(E)±10'-0" r.Fv RO4 • . 100 : iII dhistais 1. RESTAR004 iwxp (N) intri rim!, mi rxr low I I wzd "Aralliiiiigralli mom- 11111111111111111M1111111 111.11 Arl- EAIE 44 4 ▪ F\/ 4 0 a 40-8'-o" nN) GWB 1E2, Oki E ±1:1781. pp (E) •HALLWAY 106 -- • (E) ELEC • TROOM CLOSET 105. : REFLECTED CEIL NG PLAN, 24' 0 6' 12' 1 /8" =1'-O" Design per NFPA 13 — Ordinary Hazard Group 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions 0 2, 0 2 — Relocate Reliable Model 056 QR 165° Concealed Pendent 1/2 x 1/2 o 1 — Relocate pendent to Globe Model GL5601 QR Brass 155° upright 1/2 x % O Without Comments O As Noted in Red Per The Attached Letter. These plans have been reviewed by The Tukwila Fire PreventiOn• Bureau for conformance.Mth current City • standards, Acceptance is subject to errors and . • omissions -which do not authorize violations of adopted • -;•:andards and ordinances, The responsibility for the ..,:idequacy of design rests totally with the designer.- Additions, deletions evisions to these drawings after .this date will void thif: 'acceptance and require a resubmit -lei of revlSed•OraWings for subsequent approval. Final acceptance is subject to. Held test and Inspection by The -Tukwila Fire Prevention Bureau.. 'Date: 117 -- By:- FlexHeac1 Sprinkler Drop TUKWILA FIRE DEPARTMENT Please call 206-575-1407 and give this Fire Permit No. /7-S-/72-/ and exactddress for shut- • down or restoration approval. NCorrugated stainless steel hose with stairilesS steel brat • .. •• avaAble in 2', & 6' legnths , • • • Z*1 Multi -Port Bracket • • . • •• .Adjustable Hub • . . •. • • •.•.•.. q19 FLEXHEASI . . . • F.lexhebd omnieycial Ceiling Unit: • T -bar belling Installation • ' ' Model #2024,2036,2048,60,2672 TEN pommegortm PIE PROTUOT1ON John J. Abei • 97010591-03 lave! S. • ClOWri Rio Pict:Non, OApWta.,P044LL 2•Firt•-"---01 • WWWWW000Milieforaw.,,,,mosememo A \11- SPACE LOCATION SECOND FLOOR (NOT TO SCALE) CROWN • FIRE PROTECTION •INCORPORATED P.O. BOX 12113 • MILL CREEK, WASHINGTON 98082-0113 . PH. (425) 481-7669 Safari • zY NA • Tukwila WA DATE: ei .1.17 DRAWN: (5-1 PAID SEP 1i2 TUKWILA • SCALE: oc –2<T 2876 SHELL SPACE General Notes VICINITY MAP (Suite#2876) SCALE: NTS 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. EAST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE \27/ tVe 12'-0" A.F.F —12'-0" A.F.F —12'-0" A.F.F Remote Area ESP Fad u GG A 3.6% ffi DN 1Y x 1-,89. DN 1% 1 reniBrei tre ® set t cl eizel en en t3 1 tus tt a tris mra ®' ON17.x1-BY: .�; l'A x 1-'/. 0 ,t( —Existing Main ZONE T3 12'-0" A.F.F A.F.F- 011'/ x 0 ,u43\* 6vr;` ixn� iw Ordinary Group II.0.20gpm/ftZ for 980.00ft2 \27i �28� FIRE SPRINKLER SYSTEM 1/8"-1'-0" 12'-0" A.F.F 15'-0" A.F.F .TYPICAL FLEXABLE SPRINKLER CONNECTION:: FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER, BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE 2876 SHELL SPACE Remote Area: Retail # 637 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM /Ft' for 980.00 Ft' SPRINKLER Reliable F1 FR Semi-Rec ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION*: STATIC 140 RESIDUAL 20 FLOW 10900 PSI PSI GPM AT BASE OF RISER, SYSTEM REQUIRES: 283.21 GPM C°J 71.39 PSI • At time of Design 12'- 0" CLG. = 37.00% AREA REDUCTION ////////////// SWIVEL SWIVEL SWAY BRACE FITTING 318" KWIK BOLT (2114' EMBED LENGTH) BRACE PIPE • FIG.1000 "FAST CLAMP" SWAY BRACE ATTACHMENT LINE PIPE LATERAL LINE RESTRAINTS NON•THREADED BRACE PIPE FIG.4A PIPE CLAMP FOR SWAY BRACE FIG. 909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT LATERAL BRANCHLINE RESTRAINT 319• KWIK BOLT (2 114' EMBED LENGTH) BRACE PIPE STCa�o NON•THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAIN T NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III HILTI Kwik Bok II +� \ / Drilled Anchor � �- • Cut Rod Lgth Rounded to Nearest Inch Rod Coupling All Thread Rod Pipe Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan . Note on Plan: Hanger Number and A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE Vanilla Shells O Swinerton Builders CONTRACTOR: SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE R3615 34 5.6 Pendent Chrome 155°F Reliable F1 FR Semi-Rec APPROVAL: City of Tukwila HYDRAULIC REFERENCE POINT R5415 14 5.6 Pendent Brass 155°F G4A Concealed CONT. NO.: KS0407 Total = 48 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 06/19/08 It Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/DECATUR/DENVER/DULUTH/HOUSTON /KANSAS CITY LAS VEGAS /MINNEAPOLIS / PHOENIX / PORTLAND / RAPID CITY / ST. PAUL/SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 Vanilla Shells Southcenter Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SHEET. FP -1 OF 1 Z-76 .I 2876 SHELL SPACE —VICINITY- Ml P-(- a ite# 287-G)-- __..__ __ SCALE: NTS General Notes 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze, protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprtn-kler system to remain. Western States Fire Protection will modify the existing system only jn the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. EAST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE SYMBOL LEGEND REVISIONS is 1 0 0 ON1'%g1'4'/= cm al— .--E ZONEg 3ain V 1'/: x Remote Area ---r•' 414)- +0 Without Comments As Noted In Red Per The Attached Letter 1s !nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance witti current city standards. Acceptance is subiect to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibi;ity for the adequacy of design rests totally with the designer. Additions, deletions or revisions t'o these drawings atter this date will void thk3 acceptance and will require a resubmittal of revised drawings for subsequent approval. 1 Final acceptance is subject to field test and inspection bV The Tukwila Fire Prevention Bureau. Date: G'11--� By: sal fATIECE j •- Ordinary Group II'0.20gpm/ft2 for 980.00ft2 'geld stamps must b inspected Fore pit . is hung. not paint piping prior to hydrostatic test approval. FUKWILA FIRE DEPARTNIE141 Please call: 575.4407 and give this job ND.c73-S-T and exact address for shut, -own or restoration ao i. ESP_BI.NKLER SYSTEM 11 11 Sprinkler Legend _1_3-5_7-9— 11 _ E3.) FILE rffiPY :;.TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD MOUNTING BRACKET • PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID --SPRINKLER HEAD- CEILING TILE FLE;.IIEAD DETAIL NOT TO SCALE 2876 SHELL SPACE Remote Area: Retail # 637 CALCULATION DESIGN CRITERIA STANDARD NFPA #13.2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130. . Ft' DENSITY .20 GPM ! FN for 980.00 . Ft= SPRINKLER Reliable F1 FR Semi-Rec ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 283.21 GPM 0) 71.39 PSI At time of Design 12'- 0" CLC. m 37.00% AREA REDUCTION //////////// // FIG. B08 SWIVEL SWAY BRACE FITTING 3/B' KWIK BOLT 121/4' EMBED LENGTH) BRACE PIPE FIG. 1DOD f J "FAST CLAMP" SWAY BRACE ATTACHMENT LINE PIPE O LATERAL LINE RESTRAINTS 70g0 HON -THREADED BRACE PIPE no. 4A PIPE CLAMP FOR SWAY BRACE 3t8' KWIK BOLT (2 1/4' EMBED LENGTH) FIG.1309 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT LATERAL BRANCHLINE RESTRAINT 1C6.nfl NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III HILTI Kwik Bolt II Drilled Anchor -- \ i �V Rod Coupling Q Cut Rod Lgth Rounded to Nearest Inch All Thread Rodq. Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE CI) t, a co w Adam Kantner LL V) N 0 VICINITY MA. DETAIL_.___ TC) Re At Swinerton Builders CONTRI.CTO 2 -WAY EARTHQUAKE BRACE N0. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE R3615 34 5.6 HYDRAULIC REFERENCE POINT R5415 14 5.6 Pendent Pendent 111 z Chrome 155°F Reliable F1FR Semi-Rec APPROVAL: City of Tukwila Brass 155°F G4A Concealed CONT. NO.: KS0407 Total = 48 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE: 06/02/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105- REDMOND, WA - 98052 Lic. # WESTESF138QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/DECATUR /DENVER /DULUTH / HOUSTON /KANSAS CITY LAS VEGAS /MINVEAPOLIS /PHOENIX/PORTLAND/ RAPID CITY/ ST. PAUL /SALT LAKE CITY/ SEATTLE Phone: 425-881-0100 Fax 425-881-3030 Vanilla Shells Southcenter Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM r -Lt 08 Tukwila Fire rpik .24,6 2, SHEET FP -1 OF 1