HomeMy WebLinkAboutPP - 2406 SOUTHCENTER MALL - UNKNOWN TENANT - PERMITS AND PLANS2406 SOUTHCENTER MALL ASSOCIATED PERMITS 09-F-186 WESTFIELD MANAGEMENT FIRE ALARM SYSTEM BELLEVUE, WA 9800 SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL), RISER FA -04 FIRE ALARM SYSTEM FLOOR PLAN �; ` •, c.,cfmrnents :d Letter :.c- ... ::,,:cl•tued .by The Tukwila Fire -:,..,..[c rme..oce with current City ,,. 0jeci: to errors and du i-forizeviolations of adopted ;,rra :r7o ..4:.4e5. The responsibility for the ni !i,: I ;:; r .uull:y with the designer. :coil ria.;, : l; }��,I : { • ci,,!.visions to these drawings after L' U! ,�s ;c; ,:� , ccep2.arac e and will requIre),a :;urr ic:ai. of rc,Ni ed drawings for subsequent approval. Pin,a1 a .:c'ept ni is subject to field test and inspection by the Tukwila Fire Prevention Bureau, Date:. 11-I cl -(3c1 By: /k1(111,11 brrciktr. 11gti�1 a �lqr. I UKWIIA FIRE DERARTMU Please calls 575.440Z and give this job no.Oq "F- I8(, and exact address for shut. clown or 'restoration anarov? NOTICE A completed, signed, Tukwila Fire. Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test,will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE TWO 600V #12 AWG THHN/THWN TWO 600V #14 AWG THHN/THWN TWISTED TWO CONDUCTOR 300V #18 AWG FPL TW CABLE CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF CONDUIT SIZE MAXIMUM E 1/2" .12 SQUARE 3/4" .21 SQUARE 1" .34 SQUARE 1-1/4" .60 SQUARE 1-12" .82 SQUARE 2' 1.34 SQUARE ncunrs Aar rw-rn nw 4n4[ rn ini irr rut AAin Apr T0wrAI rnnu DIMENSIONS AREA .244 O.D. .0467 .210 0.D. .0346 .156 0.D. .0191 FROM THE TABLE FILL DIMENSION FROM THE WIRE. LL NCH NCH NCH NCH NCH INCH u r ,./11-, n TA ni r A SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO (TIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN --UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY SYMBOL DESCRIPTION 1 6 MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FATP FIRE ALARM CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP 5 3 15 2 EX INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD 0 DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP BOX VERIFY IN FIELD DUCT SMOKE DETECTOR AD2-XHR W/ SIEMENS HFP-11 DET DUCT HOUSING VERIFY IN FIELD SMOKE DETECTOR (PHOTOELECTRIC) HFP-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET- MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM © STROBE (WALL MOUNT) ST -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM PAM MULTI -VOLTAGE RELAY MODULE PAM -1 AIR PRODUCTS 4S BOX VERIFY IN FIELD FIRE SMOKE DAMPER F.B.O. F.B.❑, N/A VERIFY IN FIELD FATC EX JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD Fs WATERFLOW SWITCH F.B.O. F.B.O. N/A VERIFY IN FIELD TS TAMPER SWITCH F.B.D. F.B.❑, VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.D. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4.990 TEL. (206) 622-654.5 RELEASE/REVISIONS REV. BY: I z a DESCRIPTION SHOP DRAWINGS 0) 0 a NI - 0 0 o <«<C �CALE: 1 ' =1 /8" DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:10/ 14/09 BACKROUND PLAN PROVIDED BY: .JOB NUMBER: SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. BEND OR OTHER OBSTRUCTION BEND OR OTHER OBSTRUCTION DUCT DETECTOR LOCATION TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE STROBE 24K STROBE CIRCUIT SPEAKER 24K STROBE CIRCUIT STROBE SPEAKER - + 0 SPEAKER/STROBE AND STROBE WIRING LABEL SCALE 120VAC HOT NEUTRAL 0 0 SPEAKER CIRCUIT TYPICAL FOR DAMPERS DAMPER HOT O NEUTRAL 0 120VAC WMT PAM -1 BLU -O -0BLK o RED LO OR c NC NO DATA CABLE DATA CABLE nn n Vl nn —4 '0 M 0 .- 0 0 @ HTRI—R STATUS LED ND. o00 COM r 0 ILC. ///1/ GROUND NOT SHIELD HTRI—R WITH PAM -1 INSIDE 4S DEEP BOX WITH EXTENSION RING TYPICAL WIRING FOR DAMPERS & FAN CONTACTOR POWER SCALE:NONE (STATUS & CONFIRMATION) THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET \ SAMPLING TUBE INLET-- SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND 2 TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR FA -02 / SCALE:NONE STROBE CIRCUIT STROBE 0 STROBE CIRCUIT SPEAKER 0 STROBE CIRCUIT SPEAKER CIRCUIT FAN TYPICAL FAN CONTACTOR POWER CLOSED DAMPER CONTACTS NO C NC O _qm/LQ OPEN DAMPER CONTACTS NO C NC O tAiv_cp DATA CABLE —n -t 0 in 1/11/ GROUND NOT SHIELD O O HTRI—D STATUS LED NpT USED CDD ao 0 r0 (L0. tO 0 HTRI—D INSIDE 4S DEEP BOX SPEAKER CIRCUIT 12X12 JBOX GENERAL NOTES 1. 2. 3. 4. 5. FRONT VIEW \ l NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED _ REMOTE DEVICE LOOP L, 470 OHMS EOL WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPL/FPLR RED (JACKET) TC INPU TO NEXT DENCEF----. SPEAKERS ARE TAPPED AT 70.71/4 WATT. STROBES CANDELAS ARE ON THE FIELD DRAWINGS. CHECK CUT SHEETS SUPPLIED WITH PARTS BEFORE HOOKING -UP. ALL ALD LOOP WIRES MUST BE IN METAL RACEWAY. DATA OUT (+) �E DATA OUT( ) t REAR 1EW1! CABLE ALD 000 DB -I1 STANDARD SNORE DETECTOR BASE (+) (-) TYPICAL AD2-P DUCT SMOKE DETECTOR • WIRING DETAIL SCALE: NONE JUNCTI❑N BOX MOUNTED ON CEILING. FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT / / / / / / / / O O TO NEXT DEVICE 0 0 - CADDY BAR SMOKE DETECTOR.... SMOKE DETECTOR MOUNTING SCALE:NONE ANY ALD LOOP WIRE THAT GOES TO FANS / DAMPERS THAT ARE PART OF PRESSURIZING OR VENTING SMOKE CONTROL, NEED TO BE IN METAL RACEWAY AND 2 -HOUR PROTECTED (CI CABLE OR ENCLOSED IN 2 -HOUR CONCRETE OR SHEETROCK. (+)TO NEXT DEVICE OR -) STOP IF LAST DEVICE Jr DAMPER CONTACTS NO C NC O \\ TO NEXT + ^rL ADDRESSABLE DE -' DATA CABLE oin HTRI—R ®STATUS LED rLa Cql ILC 0 r 0 i DAMPER HOOT NEUTRAL /11// GROUND NOT SHIELD DAMPER STATUS CONFIRMATION & ACTIVATION SCALE:NONE " SUSPENDED ILLUMINATED CEILING TO NEXT ADDRESSABLE DEVICE NEUTRAL °0 120VAC HOT COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING Y EARTH GROUND ..(+) TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32' F (0' C TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING NFP -11 SMOKE DETECTOR DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR I.......... DB -11 / STANDARD I SMOKE DETECTOR BASE > FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) >- DATA IN (+) > REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICE E-- > ( ) DATA OUT > (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID -- CEILING ss„ssss: 111111111111► HARD LID -SPEAKER SUPPORT TILE-- BRIDGE ILE-- BRIDGE ,— 4" SQUARE DEEP BOX —, WITH 1-1/2' EXTENSION \ ---- CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE:NONE 0 CID N AC C]IL_]I[_] 00 El CI 0 ri PAD -3 0 Lai ooLI INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - C] C] 132 C]C C] C] ]IL]IC]IC] C] 3.6k EGL mor TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL ,11/7 4=0 Dj PREVIOUS ADDRESSABLE DE 0 0 0 M GROUND 0 MLR STATUS LED 0 R0. 0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL WIRING FOR HTRI-R MODULE (PAD -3 TRIP) SCALE: NONE STUD SHEET ROCK SPEAKER STROBE OR STROBE ONLY 2 NAC -4 NAC -3 NAC -2 NAC -1 Copyright vr 80" A.F.F. 0 \\ 4S DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) FAX (206) 628-4990 RELEASE/REVISIONS REV. BY: z DESCRIPTION SHOP DRAWINGS DATE 10/14/09 z CCCCC z z 0 � G z 0 2 J Q W co < 0 WFE cc) WF 'Q � \ co z Cn � o Q°- w�y.. 1 Lc T W �- N (/) N Q W 1— W 0 J 0 SCALE: 1'=1 /8" 0 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 10/1 4/09 BACKROUND PLAN PROVIDED BY: 11 WALL MOUNTED SPEAKER STROBE FIRE MOUNTING ELEVATIONS SOB NUMBER: SCALE:NONE ( SHEET 2006 by Guardian Security Systems, Inc. All Rights Reserved FA -02 } SYSTEM CALCULATIO S Panel: XLS-V Wire Resistance 2.58 tat Igo g • 1 i SET -MC @•1 5CD o sr -MC ©30CD 4 SET -MC @75CD O Z-MC©15CD o Z-MC@30CD DEVICES= 5 Total Wire Resistance ( R) !Total Device Load, Amps (I) Voltage Drop ( E ) lEOL Voltage 2i sb-MC 5cD 1 'i 261 . „ . .r.„ ..„ „„.., .„„. .,„ .... .., . „ 5 SET...Mc ©30CD . ' • ' .." 98 . . : ' - . : : 490 ..- --.- - ..,:. :: ' •-:. 'S• - ' .. • 1 !SET -MC ©75CD 1751 1751 . „ . ... . . .., . .... ....„ 2 ' Z-MC01 SCD - .. . 64 . '. .' ' _128. 0 Z-MC@3OCD 1 , 98 i 0 ' ' DEVICES= 10 . ' • ' . .: . -H 'TOTAL mA=.', _ ' ' 921 '. 14 - .. ' . - '179 MANAGEMENT 'aate:0October' :',,, 1 1 : 't " ' 4 , 'Signal` SIEMExtender%,Panel ' Battery FACP ADD ONS .. .. , 70.7V1/8 . :. . „. . 1.8 1 1t, ',. ' Current Load: Standby: Alarm: 3.6 ' - . 50.4 :..: . . Device Type Device Type Qty Amps Total Amps Total HFP 11 1 0.0022 0.0022 0.0023 0.002 Main System Board AD2-P 5 0.0635 0.0635 0.064 0.320 SET -MC ©15CD HTR -R 6 0.009600 0.0096 0.021 0.126 SET -MC @30CD HTRI-D 0 0.001600 0 0.0035 0.000 SET -MC ©75CD 5 . 0.175 0.875 , . ZR -MC @.15CD 5 . 0.0731 Amps 0.446 Amps 0.098 1.24i Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours : 0.05 ,•• Voltage Drop ( E) Alarm Current Load: 0.446 Amps For 15 Minutes 0.112 Amp -hours EOL Voltage , . . • Alarm Current Load: 1.907 25% Derating= 2.332 Amp -hours Amp -hours Total System Current Load: 2.332 Amp -hours 25% Derating= 1.100 Amp -hours Battery Pair to be Used 12VDC Amp -hours 7AH MANAGEMENT 'aate:0October' :',,, 1 1 : 't " ' 4 , 'Signal` SIEMExtender%,Panel ' Battery A v.. „ Calculations .. .. , 70.7V1/8 . :. . „. . 1.8 1 1t, ',. ' . Standby:''.',ap,Alarm:t., 14 70.7V 1/4 3.6 ' - . 50.4 :..: . . Device Type Qty Amps Total Amps Total 0 Main System Board 1 0.03 0.03 0.030 0.030 SET -MC ©15CD 3 DEVICES= 0.064 0.192 50.4 SET -MC @30CD 5 240 20.33758464 0.098 0.490 SET -MC ©75CD 5 . 0.175 0.875 , . ZR -MC @.15CD 5 . 0.064 0.320 ZR -MC ©30CD 0.098 1.24i Total Device Load, Amps (I) . 0.03 Amps 1.907 Amps : 0.05 ,•• Voltage Drop ( E) Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours EOL Voltage , . . • Alarm Current Load: 1.907 Amps For 5 Minutes= 0.160 Amp -hours 25% Derating= 1.100 Amp -hours Total System Current Load: 1.100 Amp -hours Battery Pair,,,,,e, Used:: ,,,40,..,„,,41., I''' ' '''' :'10:,.- ,, , ',., ' , ,,,..,,,,,., , ,...., i'' ' ''''',--.‘ ' ' '''' Amp-hoursP g wee> ' :7AH 1,0 CO cm 111 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS Panel: 1XLS-V Wire Resistance 2.58 VOLTAGE DROP CALCULATION REV. BY: 'aate:0October' :',,, 1 1 : 't 4: !, A VA?). ' , ,,i,,,,, 0 .. .. , 70.7V1/8 . :. . „. . 1.8 ., 0 DATE 0, o ...,. ‘t. '7. o 14 70.7V 1/4 3.6 ' - . 50.4 :..: . . 0 70.7V 1/2 7.2 0 0 701V 1 1 4.4 DEVICES= 14 TOTAL mA= 50.4 14 240 20.33758464 50.41 , . . , . . Total Wire Resistance ( R ) ( WL* 2 )* (R/ft)i 1.24i Total Device Load, Amps (I) . . • , . , ,•:, (Total Cot Load) : 0.05 ,•• Voltage Drop ( E) (E= I* R) 0.061 EOL Voltage , . . • (204:- E) • : '20.34' VOLTAGE DROP CALCULATION REV. BY: z cc DESCRIPTION SHOP DRAWINGS DATE 0, o ...,. ‘t. '7. o V1-8 V V1-9 V v - o/ V1 -11V V1-12/ V1 -13V V1-14 V1-7 v V1-6 v V1-5 \I V1 -4V V1 -3V V1-2 V V1-1 • ° S2-11 S2-10 S2-9 S2-8 S2-7 S2-6 S2-5 S2-4 S2-3 S2-2 S2-1 2S y 2S y 2S 12 2S 2S f 2S n 2S Vi 2S 2S 2S v 2S S1-6 S1-5 S1-4 S1-3 D5, (1 30 2S y 2S 17 2S 17 2S S1-2 S1-1 2S 2S RISER DIAGRAM V V EOL -S1 EOL -S2 EOL -V1 BPS ATTERY SIZING CALCULATION D 1 - 1 3 D1 -14 1-15 1-17 D 1-19 FA -BOX 2C IS.. 1 FACP D DI D 1-16 El 1-18 4P 21 D,I D 1-20 21 1-21 Di D 1-22 21 1-23 z (i) z0 _J I -SCALE: 1 '= 1 /8" DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 1 0/1 4/09 BACKROUND PLAN PROVIDED BY: ..10B NUMBER: SHEET FA -03 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved T1 NAN [ STORAC1 TENANT 1 203 1 S1-21 V1-14 STORAGE . . • ..._ .?..........` a— 2S 2V —c TENANT ENAKI r S OITA ;F. FATC FA:Li , XF\ EOL—S1 19.62V EOL—S2 19.55 EOL—V D.......� �_._.............._..... ........ n ! b 2S OOM 1 S1-3 V1-13 A rit STORAGE 23 STORAGE. S208 I STORAGE o— 2V 2S 2S tla S1-5 V1-11 2V D,I D RECEPTION 2V S2 V1-2..:_:.:_ ...._.. 2V --� 30 2V 52-6 `\ b V1-5 )'M/•Li !Vbi Ha WI V 2S 2V l/` SFEG_' arc 00 202 1 S2-7 V1-3 2V --o V1-4 2S --o 1 I1 30 2y S1-4 V1-10 D4—D,I 1-20 n 21 S2-11 1-22 2V V1-9 2V —D,I —2I� 2S i[ 2S S2-10 1 NORTH WESTFIELD MANAGEMENT SCALE I14=11 2V FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATI❑N SUBMITTAL FOR L❑CATI❑N GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACT❑R, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT, ALARM SIGNAL TO ALARM SYSTEM WILL BE SUPERVIZ❑RY, SUPERVIZED CARBON M❑N❑XIDE S ENS❑R AND SHUTDOWN THE OVEN FIELD LOCATE HVAC UNITS Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 0 W 0-5 ON O z w LU 0 Lu FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z g DESCRIPTION SHOP DRAWINGS DATE rn 0 0 2CCCCC z 0 0 z 0 J J 00 ow w w— «, Li- m co z cz� „, Q • cc w Gla° (1) - w� >- LL CC , (i) X�1n1 w SCALE: 1'=1 /8" DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 10/1 4/09 BACKROUND PLAN PROVIDED BY: .JOB NUMBER: 1 SHEET FA -04 2406 SOUTHCENTER MALL ASSOCIATED PERMITS 09-F-186 WESTFIELD MANAGEMENT FIRE ALARM SYSTEM BELLEVUE, WA 9800 SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL), RISER FA -04 FIRE ALARM SYSTEM FLOOR PLAN �; ` •, c.,cfmrnents :d Letter :.c- ... ::,,:cl•tued .by The Tukwila Fire -:,..,..[c rme..oce with current City ,,. 0jeci: to errors and du i-forizeviolations of adopted ;,rra :r7o ..4:.4e5. The responsibility for the ni !i,: I ;:; r .uull:y with the designer. :coil ria.;, : l; }��,I : { • ci,,!.visions to these drawings after L' U! ,�s ;c; ,:� , ccep2.arac e and will requIre),a :;urr ic:ai. of rc,Ni ed drawings for subsequent approval. Pin,a1 a .:c'ept ni is subject to field test and inspection by the Tukwila Fire Prevention Bureau, Date:. 11-I cl -(3c1 By: /k1(111,11 brrciktr. 11gti�1 a �lqr. I UKWIIA FIRE DERARTMU Please calls 575.440Z and give this job no.Oq "F- I8(, and exact address for shut. clown or 'restoration anarov? NOTICE A completed, signed, Tukwila Fire. Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test,will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE TWO 600V #12 AWG THHN/THWN TWO 600V #14 AWG THHN/THWN TWISTED TWO CONDUCTOR 300V #18 AWG FPL TW CABLE CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF CONDUIT SIZE MAXIMUM E 1/2" .12 SQUARE 3/4" .21 SQUARE 1" .34 SQUARE 1-1/4" .60 SQUARE 1-12" .82 SQUARE 2' 1.34 SQUARE ncunrs Aar rw-rn nw 4n4[ rn ini irr rut AAin Apr T0wrAI rnnu DIMENSIONS AREA .244 O.D. .0467 .210 0.D. .0346 .156 0.D. .0191 FROM THE TABLE FILL DIMENSION FROM THE WIRE. LL NCH NCH NCH NCH NCH INCH u r ,./11-, n TA ni r A SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO (TIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN --UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY SYMBOL DESCRIPTION 1 6 MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FATP FIRE ALARM CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP 5 3 15 2 EX INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD 0 DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP BOX VERIFY IN FIELD DUCT SMOKE DETECTOR AD2-XHR W/ SIEMENS HFP-11 DET DUCT HOUSING VERIFY IN FIELD SMOKE DETECTOR (PHOTOELECTRIC) HFP-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET- MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM © STROBE (WALL MOUNT) ST -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM PAM MULTI -VOLTAGE RELAY MODULE PAM -1 AIR PRODUCTS 4S BOX VERIFY IN FIELD FIRE SMOKE DAMPER F.B.O. F.B.❑, N/A VERIFY IN FIELD FATC EX JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD Fs WATERFLOW SWITCH F.B.O. F.B.O. N/A VERIFY IN FIELD TS TAMPER SWITCH F.B.D. F.B.❑, VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.D. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4.990 TEL. (206) 622-654.5 RELEASE/REVISIONS REV. BY: I z a DESCRIPTION SHOP DRAWINGS 0) 0 a NI - 0 0 o <«<C �CALE: 1 ' =1 /8" DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:10/ 14/09 BACKROUND PLAN PROVIDED BY: .JOB NUMBER: SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. BEND OR OTHER OBSTRUCTION BEND OR OTHER OBSTRUCTION DUCT DETECTOR LOCATION TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE STROBE 24K STROBE CIRCUIT SPEAKER 24K STROBE CIRCUIT STROBE SPEAKER - + 0 SPEAKER/STROBE AND STROBE WIRING LABEL SCALE 120VAC HOT NEUTRAL 0 0 SPEAKER CIRCUIT TYPICAL FOR DAMPERS DAMPER HOT O NEUTRAL 0 120VAC WMT PAM -1 BLU -O -0BLK o RED LO OR c NC NO DATA CABLE DATA CABLE nn n Vl nn —4 '0 M 0 .- 0 0 @ HTRI—R STATUS LED ND. o00 COM r 0 ILC. ///1/ GROUND NOT SHIELD HTRI—R WITH PAM -1 INSIDE 4S DEEP BOX WITH EXTENSION RING TYPICAL WIRING FOR DAMPERS & FAN CONTACTOR POWER SCALE:NONE (STATUS & CONFIRMATION) THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET \ SAMPLING TUBE INLET-- SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND 2 TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR FA -02 / SCALE:NONE STROBE CIRCUIT STROBE 0 STROBE CIRCUIT SPEAKER 0 STROBE CIRCUIT SPEAKER CIRCUIT FAN TYPICAL FAN CONTACTOR POWER CLOSED DAMPER CONTACTS NO C NC O _qm/LQ OPEN DAMPER CONTACTS NO C NC O tAiv_cp DATA CABLE —n -t 0 in 1/11/ GROUND NOT SHIELD O O HTRI—D STATUS LED NpT USED CDD ao 0 r0 (L0. tO 0 HTRI—D INSIDE 4S DEEP BOX SPEAKER CIRCUIT 12X12 JBOX GENERAL NOTES 1. 2. 3. 4. 5. FRONT VIEW \ l NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED _ REMOTE DEVICE LOOP L, 470 OHMS EOL WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPL/FPLR RED (JACKET) TC INPU TO NEXT DENCEF----. SPEAKERS ARE TAPPED AT 70.71/4 WATT. STROBES CANDELAS ARE ON THE FIELD DRAWINGS. CHECK CUT SHEETS SUPPLIED WITH PARTS BEFORE HOOKING -UP. ALL ALD LOOP WIRES MUST BE IN METAL RACEWAY. DATA OUT (+) �E DATA OUT( ) t REAR 1EW1! CABLE ALD 000 DB -I1 STANDARD SNORE DETECTOR BASE (+) (-) TYPICAL AD2-P DUCT SMOKE DETECTOR • WIRING DETAIL SCALE: NONE JUNCTI❑N BOX MOUNTED ON CEILING. FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT / / / / / / / / O O TO NEXT DEVICE 0 0 - CADDY BAR SMOKE DETECTOR.... SMOKE DETECTOR MOUNTING SCALE:NONE ANY ALD LOOP WIRE THAT GOES TO FANS / DAMPERS THAT ARE PART OF PRESSURIZING OR VENTING SMOKE CONTROL, NEED TO BE IN METAL RACEWAY AND 2 -HOUR PROTECTED (CI CABLE OR ENCLOSED IN 2 -HOUR CONCRETE OR SHEETROCK. (+)TO NEXT DEVICE OR -) STOP IF LAST DEVICE Jr DAMPER CONTACTS NO C NC O \\ TO NEXT + ^rL ADDRESSABLE DE -' DATA CABLE oin HTRI—R ®STATUS LED rLa Cql ILC 0 r 0 i DAMPER HOOT NEUTRAL /11// GROUND NOT SHIELD DAMPER STATUS CONFIRMATION & ACTIVATION SCALE:NONE " SUSPENDED ILLUMINATED CEILING TO NEXT ADDRESSABLE DEVICE NEUTRAL °0 120VAC HOT COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING Y EARTH GROUND ..(+) TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32' F (0' C TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING NFP -11 SMOKE DETECTOR DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR I.......... DB -11 / STANDARD I SMOKE DETECTOR BASE > FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) >- DATA IN (+) > REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICE E-- > ( ) DATA OUT > (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID -- CEILING ss„ssss: 111111111111► HARD LID -SPEAKER SUPPORT TILE-- BRIDGE ILE-- BRIDGE ,— 4" SQUARE DEEP BOX —, WITH 1-1/2' EXTENSION \ ---- CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE:NONE 0 CID N AC C]IL_]I[_] 00 El CI 0 ri PAD -3 0 Lai ooLI INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - C] C] 132 C]C C] C] ]IL]IC]IC] C] 3.6k EGL mor TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL ,11/7 4=0 Dj PREVIOUS ADDRESSABLE DE 0 0 0 M GROUND 0 MLR STATUS LED 0 R0. 0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL WIRING FOR HTRI-R MODULE (PAD -3 TRIP) SCALE: NONE STUD SHEET ROCK SPEAKER STROBE OR STROBE ONLY 2 NAC -4 NAC -3 NAC -2 NAC -1 Copyright vr 80" A.F.F. 0 \\ 4S DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) FAX (206) 628-4990 RELEASE/REVISIONS REV. BY: z DESCRIPTION SHOP DRAWINGS DATE 10/14/09 z CCCCC z z 0 � G z 0 2 J Q W co < 0 WFE cc) WF 'Q � \ co z Cn � o Q°- w�y.. 1 Lc T W �- N (/) N Q W 1— W 0 J 0 SCALE: 1'=1 /8" 0 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 10/1 4/09 BACKROUND PLAN PROVIDED BY: 11 WALL MOUNTED SPEAKER STROBE FIRE MOUNTING ELEVATIONS SOB NUMBER: SCALE:NONE ( SHEET 2006 by Guardian Security Systems, Inc. All Rights Reserved FA -02 } SYSTEM CALCULATIO S Panel: XLS-V Wire Resistance 2.58 tat Igo g • 1 i SET -MC @•1 5CD o sr -MC ©30CD 4 SET -MC @75CD O Z-MC©15CD o Z-MC@30CD DEVICES= 5 Total Wire Resistance ( R) !Total Device Load, Amps (I) Voltage Drop ( E ) lEOL Voltage 2i sb-MC 5cD 1 'i 261 . „ . .r.„ ..„ „„.., .„„. .,„ .... .., . „ 5 SET...Mc ©30CD . ' • ' .." 98 . . : ' - . : : 490 ..- --.- - ..,:. :: ' •-:. 'S• - ' .. • 1 !SET -MC ©75CD 1751 1751 . „ . ... . . .., . .... ....„ 2 ' Z-MC01 SCD - .. . 64 . '. .' ' _128. 0 Z-MC@3OCD 1 , 98 i 0 ' ' DEVICES= 10 . ' • ' . .: . -H 'TOTAL mA=.', _ ' ' 921 '. 14 - .. ' . - '179 MANAGEMENT 'aate:0October' :',,, 1 1 : 't " ' 4 , 'Signal` SIEMExtender%,Panel ' Battery FACP ADD ONS .. .. , 70.7V1/8 . :. . „. . 1.8 1 1t, ',. ' Current Load: Standby: Alarm: 3.6 ' - . 50.4 :..: . . Device Type Device Type Qty Amps Total Amps Total HFP 11 1 0.0022 0.0022 0.0023 0.002 Main System Board AD2-P 5 0.0635 0.0635 0.064 0.320 SET -MC ©15CD HTR -R 6 0.009600 0.0096 0.021 0.126 SET -MC @30CD HTRI-D 0 0.001600 0 0.0035 0.000 SET -MC ©75CD 5 . 0.175 0.875 , . ZR -MC @.15CD 5 . 0.0731 Amps 0.446 Amps 0.098 1.24i Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours : 0.05 ,•• Voltage Drop ( E) Alarm Current Load: 0.446 Amps For 15 Minutes 0.112 Amp -hours EOL Voltage , . . • Alarm Current Load: 1.907 25% Derating= 2.332 Amp -hours Amp -hours Total System Current Load: 2.332 Amp -hours 25% Derating= 1.100 Amp -hours Battery Pair to be Used 12VDC Amp -hours 7AH MANAGEMENT 'aate:0October' :',,, 1 1 : 't " ' 4 , 'Signal` SIEMExtender%,Panel ' Battery A v.. „ Calculations .. .. , 70.7V1/8 . :. . „. . 1.8 1 1t, ',. ' . Standby:''.',ap,Alarm:t., 14 70.7V 1/4 3.6 ' - . 50.4 :..: . . Device Type Qty Amps Total Amps Total 0 Main System Board 1 0.03 0.03 0.030 0.030 SET -MC ©15CD 3 DEVICES= 0.064 0.192 50.4 SET -MC @30CD 5 240 20.33758464 0.098 0.490 SET -MC ©75CD 5 . 0.175 0.875 , . ZR -MC @.15CD 5 . 0.064 0.320 ZR -MC ©30CD 0.098 1.24i Total Device Load, Amps (I) . 0.03 Amps 1.907 Amps : 0.05 ,•• Voltage Drop ( E) Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours EOL Voltage , . . • Alarm Current Load: 1.907 Amps For 5 Minutes= 0.160 Amp -hours 25% Derating= 1.100 Amp -hours Total System Current Load: 1.100 Amp -hours Battery Pair,,,,,e, Used:: ,,,40,..,„,,41., I''' ' '''' :'10:,.- ,, , ',., ' , ,,,..,,,,,., , ,...., i'' ' ''''',--.‘ ' ' '''' Amp-hoursP g wee> ' :7AH 1,0 CO cm 111 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS Panel: 1XLS-V Wire Resistance 2.58 VOLTAGE DROP CALCULATION REV. BY: 'aate:0October' :',,, 1 1 : 't 4: !, A VA?). ' , ,,i,,,,, 0 .. .. , 70.7V1/8 . :. . „. . 1.8 ., 0 DATE 0, o ...,. ‘t. '7. o 14 70.7V 1/4 3.6 ' - . 50.4 :..: . . 0 70.7V 1/2 7.2 0 0 701V 1 1 4.4 DEVICES= 14 TOTAL mA= 50.4 14 240 20.33758464 50.41 , . . , . . Total Wire Resistance ( R ) ( WL* 2 )* (R/ft)i 1.24i Total Device Load, Amps (I) . . • , . , ,•:, (Total Cot Load) : 0.05 ,•• Voltage Drop ( E) (E= I* R) 0.061 EOL Voltage , . . • (204:- E) • : '20.34' VOLTAGE DROP CALCULATION REV. BY: z cc DESCRIPTION SHOP DRAWINGS DATE 0, o ...,. ‘t. '7. o V1-8 V V1-9 V v - o/ V1 -11V V1-12/ V1 -13V V1-14 V1-7 v V1-6 v V1-5 \I V1 -4V V1 -3V V1-2 V V1-1 • ° S2-11 S2-10 S2-9 S2-8 S2-7 S2-6 S2-5 S2-4 S2-3 S2-2 S2-1 2S y 2S y 2S 12 2S 2S f 2S n 2S Vi 2S 2S 2S v 2S S1-6 S1-5 S1-4 S1-3 D5, (1 30 2S y 2S 17 2S 17 2S S1-2 S1-1 2S 2S RISER DIAGRAM V V EOL -S1 EOL -S2 EOL -V1 BPS ATTERY SIZING CALCULATION D 1 - 1 3 D1 -14 1-15 1-17 D 1-19 FA -BOX 2C IS.. 1 FACP D DI D 1-16 El 1-18 4P 21 D,I D 1-20 21 1-21 Di D 1-22 21 1-23 z (i) z0 _J I -SCALE: 1 '= 1 /8" DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 1 0/1 4/09 BACKROUND PLAN PROVIDED BY: ..10B NUMBER: SHEET FA -03 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved T1 NAN [ STORAC1 TENANT 1 203 1 S1-21 V1-14 STORAGE . . • ..._ .?..........` a— 2S 2V —c TENANT ENAKI r S OITA ;F. FATC FA:Li , XF\ EOL—S1 19.62V EOL—S2 19.55 EOL—V D.......� �_._.............._..... ........ n ! b 2S OOM 1 S1-3 V1-13 A rit STORAGE 23 STORAGE. S208 I STORAGE o— 2V 2S 2S tla S1-5 V1-11 2V D,I D RECEPTION 2V S2 V1-2..:_:.:_ ...._.. 2V --� 30 2V 52-6 `\ b V1-5 )'M/•Li !Vbi Ha WI V 2S 2V l/` SFEG_' arc 00 202 1 S2-7 V1-3 2V --o V1-4 2S --o 1 I1 30 2y S1-4 V1-10 D4—D,I 1-20 n 21 S2-11 1-22 2V V1-9 2V —D,I —2I� 2S i[ 2S S2-10 1 NORTH WESTFIELD MANAGEMENT SCALE I14=11 2V FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATI❑N SUBMITTAL FOR L❑CATI❑N GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACT❑R, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT, ALARM SIGNAL TO ALARM SYSTEM WILL BE SUPERVIZ❑RY, SUPERVIZED CARBON M❑N❑XIDE S ENS❑R AND SHUTDOWN THE OVEN FIELD LOCATE HVAC UNITS Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 0 W 0-5 ON O z w LU 0 Lu FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z g DESCRIPTION SHOP DRAWINGS DATE rn 0 0 2CCCCC z 0 0 z 0 J J 00 ow w w— «, Li- m co z cz� „, Q • cc w Gla° (1) - w� >- LL CC , (i) X�1n1 w SCALE: 1'=1 /8" DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 10/1 4/09 BACKROUND PLAN PROVIDED BY: .JOB NUMBER: 1 SHEET FA -04