Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 2600 SOUTHCENTER MALL FC-2 - SHARKYS WOODFIRE MEXICAN GRILL - PERMITS AND PLANS
2600 SOUTHCENTER MALL FC -2 FOOD COURT ASSOCIATED PERMITS 14-F-006 08-F-321 14-S-015 14-S-011 08-S-238 14-H-021 08-H-266 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address: 2600 Southcenter Mall FC -2, 98188 Suite Number: 2270 Floor: Tenant Name: Chipotle Mexican Grill New Tenant? Q - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address: 1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City E-mail Address: Fax Number:206.628.4990 State Zip Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): ✓ i v Scope of Work (please provide detailed information): Adding 9 devices to existing FRCP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O NER OR ALJTHO Z D AGENT: Signature: Date: Print Name: Karina Veliz < Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 4431t*1144 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: ? Qt �C7ZA1 teri'er Ma- a- I) Suite Number: ":2. Floor: Tenant Name: CY\ TO 1 - Property Owner's Name: W e�k-c1- ' pnaiXsenne !-T New Tenant? ❑ - Yes -No Mailing Address: CONTACT PERSON -if there are questions about the submittal. Name: Company Name: Mailing Address: City Crown 1 \vim %-vec+\c 11 State Zip Day Telephone: 2 25 14R1 1 "7 CA69 City State Zi E-mail Address: e . �\C Q o (rO L v . COYY\ Fax Number: L2-\ �vc S Total number of new/relocated devices or sprinkler heads: (—,5� Valuation of Project (contractor's bid price): $ —7, Ce Scope of Work (please provide detailed information): osy ark POA %-y\ofilcc> PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 4 j 2OR AUTHORIZED AGENT: JJ j Signature: Z 9-r 1 . Date: /23 �! / Print Name:</C-�S5lt'2 150 /12SOn Day Telephone: Q75' /' -7( Plan Permit App.doc 1/2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: Z(, 0 0 50 tcrvi Gg 4 6 R. M4 1. -1 --- Tenant Name: C N t P OT Le - New Tenant? ['Yes ❑ - No Property Owner's Name: *S-rFI --D 1a07CRTI -"AX 6Pi-, King Co. Assessor's Tax No.: Suite Number: FC- - 2 -Floor: Mailing Address: ?o Sc( I3 oR4 O CARA-54349 City CONTACT PERSON -if there are questions about the submittal. Name: -.AY 5ci-tNEBC-'t Company Name: Mailing Address: J,ScArNeto ►rtkoo8 cow► Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ i ✓ e Scope of Work (please provide detailed information): t100 t- LAP ?R.6 - Pt -U P keD WEsST crt6 ' IG4L P A J -- 5yS EM lAJ kr z- (7N QA/J((6 t}oo'D E-mail Address: �a 9' 20 State Zip Day Telephone: 20(0 .72_6 09 4 U RAT Hoop eat) D ta.cC- ;r: 2v I S 1 t rC - (, (o o (V-1* Ave S. SEA True City WoN 9'g Ib ' State Zip Fax Number: 7-0(0 To 1 2J O "] PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Ja j Se., J 6 c.x Plan Permit App.doc Date: 1/77 12-01t4 Day Telephone: 2-0 Co ` 7 ZCo ' O 9 4 O 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Sharkey's 2600 Southcenter Mall FC -02 Permit No.: 08-S-238 Date: May 29, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/z inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Sharkeys 2600 Southcenter Mall space FC -2 Permit No.: 08-H-266 Date: June 4, 2008 Reviewer: Steve Kohler Fire Protection Inspector/Plan Review (206)575-4407 • Nozzle heights above appliances to be per manufacturers installation guidelines. • Install splash guards between fryers and ranges/charbroilers. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Chipotle Mexican Grill 2600 Southcenter Mall FC -2 Permit No.: 14-S-015 Date: February 4, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods Tess than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 % inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Chipotle Mexican Grill 2600 Southcenter Mall FC-2Pb Permit No.: 14-H-021 /4 Date: February 6, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Nozzle heights above appliances to be per manufacturers installation guidelines. • Fryers shall be installed with at least a 16 inch space between the fryer and surface flames from adjacent cooking equipment or a minimum 8 inch high steel or tempered glass baffle plate shall be installed between the appliances. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust system whenever cooking operations occur. The activation of the exhaust system shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. • A minimum 110 candela horn/strobe shall be installed above the kitchen hood suppression system manual pull station at a height of 80 inches above the floor. • A separate fire alarm permit from the Tukwila Fire Department is required for all fire alarm work. • The suppression system manual pull station shall be located no closer than 10 ft. and no farther than 20 ft. from the cooking equipment and be placed at a height of 42 to 48 inches above the floor. • The inside lower edge of the hood shall overhang or extend a horizontal distance of not Tess than 6 inches beyond the edge of the top horizontal surface of the appliance on all open sides. The vertical distance between the front lower lip of the hood and such surface shall not exceed 4 feet. • If cooking appliances are wheeled, the appliance wheels shall be set in tracks permanently mounted to the floor to ensure appliance is returned to original location if moved for cleaning or maintenance. Hydraulic Overview Job Number: KS0414 • Job Job Number Design Engineer KS0414 CHRIS J. ISAAC Job Name Phone FAX SHARKY'S 206-491-6679 425-881-3030 Address I State Certificabonticense Number 2600 SOUTH CENTER MALL FC -02 WESTESF136QF Address 2 Aryl CITY OF TUKWILA City State Zip Code Job Site TUKWILA WA 98188 SOUTH CENTER MALL System Density Area of Application 0.200gpm/ft2 743.00ft2 (Actual 742.22ft2) Most Demanding Sprinkler Data Hose Streams 5.6 K -Factor 20.70 at 13.664 250.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 103.50ft2 15 System Pressure Demand System Flow Demand 65.822 358.39 Total Demand Pressure Result 608.39 @ 65.822 • +73.601 (52.8%) Supplies Check Point Gauges Node Fiow(oom) Hose Fiow(opm) Static(psi) Residual(osil Identifier Pressure(psi) K-Factor(K? Flow(oom) 1 10900.00 250.00 140.000 20.000 Cillis 410. 1 i t. //1 SHARKY FP-1.cad Supply at Node 1 (10900.00, 250.00, 140.000, 20.000) 150 _ 135 Static Pressure i 140.000 120 R wij�s1 105 4,_s A 90 _ .N a F- 75 y,608.39 wi h hose streams -""t ;v 60 358.39 @ 65 822 I; a 45 11 11 il "' 30 System demand curve [ — — — — -- 15 10900.00 @ 20.000{ E. 0 X11111111111111111111 111111 111 111111111 1111111111 111111111 1 1 1 1 1 1 1 1 1 111111111 11P 33000 5500 66007700 8800 990011000 Water flow, gpm © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 05/23/2008 3:19:OOPM Page 1 Hydraulic Summary •Job Number: KS0414 Job Job Number KS0414 Job Name SHARKY'S Address 1 2600 SOUTH CENTER MALL FC -02 Address 2 City State Zip Code TUKWILA WA 98188 Desgn Engineer CHRIS J. ISAAC State CertificabonlLicense Number WESTESF136QF AHJ CITY OF TUKWILA Job Site SOUTH CENTER MALL Drawing Name SHARKY FP-1.cad System I Remote Area(s) Most Demanding Sprinkler Data 5.6 K -Factor 20.70 at 13.664 Hose Allowance At Sauce 250.00 Additional Hose Supplies Node Flow(gpm) Occupancy Ordinary Group II Density 0.200gpm/ft2 Number Of Sprinklers Calculated 15 Area of Application 743.00ft2 (Actual 742.22ft2) Coverage Per Sprinkler 103.50ft2 Total Hose Streams 250.00 System Flow Demand Total Water Required (Including Hose Allowance) 358.39 608.39 Maamum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 20.36 between nodes 529 and 537 Maximum Velocity Under Ground 1.35 between nodes 1 and 1371 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 3530.90gal 10.09gal Supplies Hose Flow Static Residual @ Flow Node (gpm) (psi) (psi) (gpm) Available @ Total Demand (psi) (gpm) Required Safety Margin (psi) (psi) 1 250.00 140.000 20.000 10900.00 139.424 608.39 65.822 73.601 Contractor Contractor Number KS0414 Contractor Name Western States Fire Protection (Redmond) Address 1 7102 180th Ave NE, Suite A-105 Address 2 City State Zip Code Redmond WA 98052 Contact Name Chris J Isaac Phone (425)881-0100 FAX (425)881-3030 E-mail chris.isaac@wsfp.us Web -Site Contact Title Designer Extension !� ©M.E.P.CAD, Inc. ?s AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:24PM Page 2 1 .411 Summary Of Outflowing Devices Job Number: KS0414 Report Description: Ordinary Group II Device Sprinkler Sprinkler Sprinkler Sprinkler r* Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler 115 102 103 106 101 104 105 110 107 109 111 108 114 112 113 Most Demanding Sprinkler Data Actual Flow Minimum Flow K -Factor Pressure (gpm) (gpm) (K) (psi) 29.78 20.75 20.84 23.83 20.70 20.93 22.14 24.14 23.99 24.10 24.25 24.08 28.68 25.09 25.11 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 28.273 13.733 13.845 18.101 13.664 13.966 15.633 18.577 18.348 18.522 18.747 18.486 26.228 20.077 20.100 1, © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:25PM Page 3 Node Analysis Job Number: KS0414 Report Description: Ordinary Group 11 Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 472 15'-9 P0(8c0) 38.251 480 18'-9 P0(5'-0) 36.009 498 17-9 T(5'-0) 15.940 504 17'-9 T(5'-0) 15.198 529 15'-9 P0(8'-0) 38.254 537 17'-9 P0(5'-0) 22.662 538 17'-9 PO(5'-0) 19.680 540 17'-9 P0(5'-0) 18.664 542 17'-9 E(2'-0) 18.184 638 15'-9 P0(8'-0) 38.319 673 17'-9 P0(5'-0) 23.522 646 17-9 PO(5'-0) 23.241 647 17-9 PO(5'-0) 2t933 651 17'-9 E(2'-0) 21.111 652 ' 18'-3 2T(5'-0) 19.247 703 14'-3 P0(8'-0) 39.493 712 17'-9 PO(5'-0) 28.415 714 17'-9 E(2'-0) 27.710 767 17'-9 T(5'-0) 24.287 1191 18'-3 2P0(26'-4) 42.497 1290 -16'-1 P0(37'-8%) 58.597 1371 -14'-1' BFP(-4.500) 62.352 1405 -16-1 LtE(16'-0) 58.652 115 10'-63 Spr(-28.273) 28.273 102 7-0%4 Sp (-13.733) 13.733 103 8'-0%4 Spr(-13.845) 13.845 106 10'-6%4 Spr(-18.101) 18.101 101 10'-O% Spr(-13.664) 13.664 104 7-0%4 Spr(-13.966) 13.966 105 10'-6V4 Spr(15.633) 15.633 110 10'-6%4 Spr(-18.577) 18.577 107 10'-0% Spr(-18.348) 18.348 109 10'-6%4 Spr(-18.522) 18.522 111 10'-6%4 Spr(-18.747) 18.747 108 10'-0%4 Spr(-18.486) 18.486 114 10'-0% Spr(-26.228) 26.228 112 10'-0%4 Spr(-20.077) 20.077 113 10'-0%4 Spr(-20.100) 20.100 1 -22'-0 S 65.822 29.78 20.75 20.84 23.83 20.70 20.93 22.14 24.14 23.99 24.10 24.25 24.08 28.68 25.09 25.11 358.39 (, © M.E.P.CAD, Inc. ,;;.4 AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:25PM Page 4 1 Hydraulic Analysis Job Number: KS0414 Report Description: Ordi Pipe Type Downstream Upstream Diameter Elevation Flow Discharge Velocity K -Factor HWC Pt Friction Loss Length Pressure Pn Fittings Eq. Length Summary Total Length = Route 1 DR 1.0490 Q=20.70 7.68 C=120 0.1386.82 29'-7% Pf 5.630 101 10'-0% q=20.70 K=5.6 13.664 Spr(-13.664) 11-0 Pe -3.354 498 17'-9 15.940 3E(2'-0), T(5'-0) 40'-7% Pv BL 1.0490 Q=41.54 15.42 C=120 0.503015 2'-5% Pf 2.245 498 17'-9 15.940 2'-0 Pe -0.000 542 17'-9 18.184 E(2'-0) 4'-5%2 Pv BL 1.6100 Q=41.54 6.55 C=120 0.06244.8 7'-8 Pf 0.479 542 17'-9 18.184 Pe 540 17'-9 18.664 7'-8 Pv BL 1.6100 Q=83.22 13.11 C=120 0.225844 4'-6 Pf 1.016 540 17'-9 18.664 Pe 538 17-9 19.680 4'-6 Pv BL 1.6100 Q=105.36 1.6.60 C=120 0.349425 8'-6''A Pf 2.982 538 17'-9 19.680 Pe 537 17'-9 22.662 8'-61A Pv BL L 1.6100 Q=129.18 20.36 C=120 0.50.9.507 16'-10% Pf 14.725 537 17'-9 22.662 12'-0 Pe 0.867 529 15'-9 38.254 2LtE(2'-0), PO(8'-0) 28'-10' Pv CM 4.2600 Q=158.96 3.5.8 C=120 0.006544 10'-0 Pf 0.065 529 15'-9 38.254 Pe 638 15'-9 38.319 10'-0 Pv CM 4.2600 Q=279.51 6.29 C=120 0.01858.9 10'-3 Pf 0.523 638 15'-9 38.319 17'-11 Pe 0.650 703 14'-3 39.493 2fE(8'-11'/2) 28'-l% Pv CM 4.2600 Q=358.39 8.07 C=120 0.029443 98'-6% Pf 4.731 703 14'-3 39.493 62.-1% Pe -1.727 1191 18'-3 42.497 4fE(8'-11%2), PO(26'-4) 160'-8 Pv CM 6.3570 Q=358.39 3.62 C=120 0.00419.2 133'-10 Pf 1.220 1191 18'-3 42.497 157'-2 Pe 14.881 1290 -16-1 58.597 5fE(12'-7), BV(12'-7), CV(40'-2%), 291'-0 Pv GV(3'-9%), PO(37'-8%) FM 8.3290 Q=358.39 2.11 C=120 0.001124 16'-5''A Pf 0.055 1290 -16'-1 58.597 32'-0 Pe 0.000 1405 -16-1 58.652 fE(16'-0), LtE(16'-0) 48'-5% Pv FM 10.4200 Q=358.39 1.35 C=120 0.000378 28'-2% Pf 4.542 1405 -16-1 58.652 83'-0 Pe -0.842 1371 -14'-1% 62.352 4LtE(16'-0), BV(19'-0), BFP(-4.500) 111'-2% Pv UG 10.4000 Q=358.39 1.35 C=140 0.000287 110'-2 Pf 0.064 1371 -14.-1% 62.352 111'-7% Pe 3.407 1 -22'-0 65.822 E(35'-1), 3LtE(25'-6), S 221'-9% Pv cii Route 2 DR 1.0490 Q=20.75 7.70 C=120 0.139334 37'-11 Pf 6.120 102 7'-0% q=20.75 K=5.6 13.733 Spr(-13.733) 6'-0 Pe -4.655 504 17'-9 15.198 3E(2'-0) 43'-11 Pv BL 1.0490 Q=41.68 15.47 C=120 0.506237 1'-10% Pf 3.466 504 17'-9 15.198 5'-0 Pe 540 17'-9 18.664 PO(5'-0) 6-10% Pv Route 3 DR 1.0490 Q=20.84 7.74 C=120 0.140385 37'-0 Pf 6.316 103 8'-0% q=20.84 K=5.6 13.845 Spr(-13.845) 8'-0 Pe -4.221 498 17'-9 . 15.940 4E(2'-0) 45'-0 Pv a Route 4 DR 1.0490 Q=20.93 7.77 C=120 0.141522 32'-7% Pf 5.887 104 7-0% q=20.93 K=5.6 13.966 Spr(-13.966) 9'-0 Pe -4.655 504 17'-9 15.198 2E(2'-0), T(5'-0) 41'-7% Pv ++ Route 5 DR 1.0490 Q=22.14 8.22 C=120 0.157075 30'-9 Pf 7.185 105 10'-6'/+ q=22.14 K=5.6 15.633 Spr(-15.633) 15'-0 Pe -3.138 538 17-9 19.680 5E(2'-0), PO(5'-0) 45'-9 Pv Route 6 DR 1.0490 Q=23.83 8.84 C=120 0.179889 31'-9'% Pf 7.698 106 10'-6% q=23.83 K=5.6 18.101 Spr(-18.101) 11-0 Pe -3.138 537 17'-9 22.662 3E(2'-0), PO(5'-0) 42'-9% Pv Route 7 DR 1.0490 Q=23.99 8.90 C=120 0.182154 13'-6%2 Pf 4.470 107 10'-0'% q=23.99 K=5.6 18.348 Spr(-18.348) 11'-0 Pe -3.571 652 18'-3 19.247 3E(2'-0), T(5'-0) 24'-6'/2 Pv BL 1.0490 Q=48.06 17.84 C=120 0.658953 0'-6 Pf 1.647 652 18'-3 19.247 2'-0 Pe 0.217 651 17'-9 21.111 E(2'-0) 2'-6 Pv M.E.P.CAD, Inc. ?1 AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:26PM Page 5 1 Hydraulic Analysis Job Number: KS0414 Report Description: Ordinary Group I Pipe Type Diameter Flow Velocity Downstream Elevation Discharge K -Factor Upstream HWC Pt Friction Loss Pn Fittings Length Pressure Eq. Length Summary Total Length BL 1.6100 0=48.06 7.57 C=120 0.081807 10'-0'/4 Pf 0.822 651 17'-9 21.111 Pe -0.000 647 17'-9 21.933 10'-0% Pv BL 1.6100 0=72.17 11.37 C=120 0.173509 7-61,4 Pf 1.308 647 17'-9 21.933 Pe 646 17'-9 23.241 7'-6%: Pv B_ L 1.6100 0=96.41 15.19 C=120 0.296520 V-11% Pf 0.281 646 17'-9 23.241 Pe 673 - 17-9 23.522 0'-11 % Pv BL 1.6100 Q=120.55 19.00 C=120 0.448295 19'-1 Pf 13.931 673 17'-9 23.522 12'-0 Pe 0.867 638 15-9 38.319 2LtE(2'-0), PO(8'-0) 31'-1 Pv Q. Route 8 DR 1.0490 0=24.08 8.94 C=120 0.183424 12'-7% Pf 4.332 108 10'-0%4 q=24.08 K=5.6 18.486 Spr(-18.486) 11-0 Pe -3.571 652 18'-3 19.247 3E(2'-0), T(5'-0) 23'-7% Pv Route 9 DR 1.0490 0=24.10 8.95 C=120 0.1837.55 28'-7% Pf 6.549 109 10'-6% q=24.10 K=5.6 18.522 Spr(-18.522) 7'-0 Pe -3.138 647 17'-9 21.933 E(2'-0), PO(5'-0) 35'-7% Pv Route 10 DR 1.0490 0=24.14 _8.96 C=120 _0.184262 32'-10%4 Pf 8.082 110 10'-6%4 q=24.14 K=5.6 18.577 Spr(-18.577) 11-0 Pe -3.138 673 17'-9 23.522 3E(2'-0), PO(5'-0) 43'-101/4 Pv Route 11 DR 1.0490 0=24.25 9.00 C=120 0.185814 30'-1 Pf 7.632 111 10'-6% q=24.25 K=5.6 18.747 Spr(-18.747) 11'-0 Pe -3.138 646 17'-9 23.241 3E(2'-0), PO(5'-0) 41'-1 Pv Route 12 DR 1.0490 0=25.09 9.31 C=120 0.197983 29'-2% Pf 7.564 112 10'-0%4 q=25.09 K=5.6 20.077 Spr(-20.077) 9'-0 Pe -3.354 767 17'-9 24.287 2E(2'-0), T(5'-0) 38'-2'h Pv BL 1.0490 0=50.20 18.64 C=120 0.7.1409.9 2'-93/2 Pf 3.423 767 17'-9 24.287 2'-0 Pe 714 17'-9 27.710 E(2'-0) 4'-9%: Pv BL 1.6100 Q=50.20 7.91 C=120 0.088653 7'-11'A Pf 0.705 714 17'-9 27.710 Pe 712 17'-9 28.415 7-11 % Pv BL 1.6100 0=78.88 12.43 C=120 0.204541 34'-9 Pf 9.560 712 17'-9 28.415 12'-0 Pe 1.517 703 14'-3 39.493 2LtE(2'-0), PO(8'-0) 46-9 Pv Route 13 DR 1.0490 0=25.11 9.32 C=120 0.198189 32'-0% Pf 7.542 113 10'-0% q=25.11 K=5.6 20.100 Spr(-20.100) 6'-0 Pe -3.354 767 17'-9 24.287 3E(2'-0) 38'-0% Pv a Route 14 DR 1.0490 0=28.68 10.65 C=120 0.253501 10'-10%4 Pf 5.542 114 10'-0'/4 q=28.68 K=5.6 26.228 Spr(-26.228) 11'-0 Pe -3.354 712 17'-9 28.415 3E(2'-0), PO(5'-0) 21'-10% Pv c. Route 15 DR 1.0490 0=29.78 11.05 C=120 0.271738 30'-7% Pf 11.307 115 10'-6'/4 q=29.78 K=5.6 28.273 Spr(-28.273) 11-0 Pe -3.571 480 18'-9 36.009 3E(2'-0), PO(5'-0) 41'-7%4 Pv BL 1.6100 Q=29.78 4.69 C=120 0.033735 15'-11 Pf 0.942 480 18'-9 36.009 12'-0 Pe 1.301 472 15'-9 38.251 2LtE(2'-0), PO(8'-0) 27'-11 Pv CM 4.2600 0=29.78 0.67 C=120 0.000295 8'-101/2 Pf 0.003 472 15-9 38.251 Pe 529 15-9 38.254 8'-10'/z Pv Equivalent Pipe Lengths of Valves and Fittings (C=120 only) • C Value Multiplier 4 )4.87 Actual Inside Diameter 4 87 ( Value Of C 100 130 140 150 = Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 k, ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:26PM Page 6 Ail -Hydraulic Analysis Job Number: KS0414 Report Description: Ordinary Group II Pipe Type Downstream Upstream Diameter Elevation Flow Discharge Velocity HWC K -Factor Pt Friction Loss Pn Fittings Length Pressure Eq. Length Summary Total Length Pipe Type Legend Units Legend Fittings Legend AO BL CM DN DR DY FM FR MS OR RN SP ST UG Arm -Over Branch Line Cross Main Drain Drop Dynamic Feed Main Feed Riser Miscellaneous Outrigger Riser Nipple Sprig Stand Pipe Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV AngV b BaIV BFP BV C cplg Cr CV DeIV DPV E EE Eel Ee2 f FDC fE fEE flg FN fT 9 GIoV GV Hose HV Hyd LtE mecT Noz P1 P2 PIV PO PrV PRV red S sCV Spr St T Tr U WirF WMV z Alarm Valve Angle Valve Bushing Ball Valve Backflow Preventer Butterfly Valve Cross Flow Turn 90° Coupling Cross Run Check Valve Deluge Valve Dry Pipe Valve 90° Elbow 45° Elbow 11%° Elbow 22W Elbow Flow Device Fire Department Connection 90° FireLock(TM) Elbow 45° FireLock(TM) Elbow Flange Floating Node FireLock(TM) Tee Gauge Globe Valve Gate Valve Hose Hose Valve Hydrant Long Turn Elbow Mechanical Tee Nozzle Pump In Pump Out Post Indicating Valve Pipe Outlet Pressure Relief Valve Pressure Reducing Valve Reducer/Adapter Supply Swing Check Valve Sprinkler Strainer Tee Flow Turn 900 Tee Run Union Wirsbo Water Meter Valve Cap 0,k,© M.E.P.CAD, Inc. ;?4 AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:26PM Page 7 • 4: Hydraulic Graph ` Job Number: KS041 Report Description: Ordinary Group Pressure, psi c Supply at Node 1 • • Static Pressure 140.000 •608.39 358.39 with hose @ 65.822 streams System demand curve 10900.00 @ 20.000_ IIIIIIII1uuII I I I I I I I I 111 1 1 1 1 1 1 1 1 l I i l I I I 1 1 1 1 1 1 1 1 L 11 1 1 1 1 1 1 t 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 III 11111 I V p 11002200 3300 4400 5500 6600 7700 Water flow, gpm 8800 9900 11000 Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.424 @ 608.39 System Demand 358.39 @ 65.822 System Demand (Including Hose Allowance) 608.39 @ 65.822 Cm, ©M.E.P.CAD, Inc. y AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:27PM Page 8 OilIS Flow Diagram (Top View) 1 Job Number: KS0414 Report Description: Ordinary Group 11 (AA Cc) M F P r.An Inc. =�3AutoSPRINK® VR5 v5.1.32 05/23/2008 3:19:01 PM Page 2 uS e. r vc G f' Pang .5 `1nY R%A '1124124/2 AI P • 11: n f 'a• a• .. I wi M 6 M v z 1 1 a CAD I r —C -a - I „0on'(50` ; . I I *",° I I~ --1 r= • x0 0 0 0- 0 rt 1 1 I I r k 1 Y O O 4 I WO aN 1P •p 1 3, 4r to 'c O _ l ill? .A si ix F x� 4 la r -n 5 Fl geO x ro 6 E` g i P 3,.7 c.. 3 K1 04 Q ' , a ....., r : Ce -! o �ro o V Cofl N ..cJ O N v) n F3 v. co 3 � u X lSP1 Page: 3 Nola - Fire Systems - Parts List Report 5/20/08 4:35 PM • Fire System Parts List Job # 700611 - Sharky's - Seattle WA Location: Seatle, WA Fire System # 1 Ansul R102 ANSUL-3.0/3.0/1.5 Tag: Hoods Covered: Hood # 1Hood # 3 Gas Valve(s) : Supplied by Ship Otv Item CAS # Vendor # Description Dist CAS Inst Loose 1 1 AT - 1.5 AT - 1.5 TANK(#1A) - 1.5 Gallon SS Tank (for use with 1 0 Automan Release, Actuator, or SS Enclosure (UL)) 2 1 AT - 3.0 AT - 3.0 TANK(#1 B) - 3.0 Gallon SS Tank (for use with 2 0 Automan Release, Actuator, or SS Enclosure (UL)) 1 2 AP - AR AP - AR AUTOMAN RELEASE - Ansul Automan 1 0 Mechanical Release (UL) Tank sold separately 1 3 AP - AE AP - AE ENCLOSURE - Stainless Steel Enclosure Assembly (UL) 1 0 1 4 AP - AA AP - AA ACTUATOR - Ansul Regulated Actuator 1 0 Assembly (UL) 2 5 LIQ -3.0 79372 AGENT - Ansulex Low PH Wet Chemical Agent, 2 0 3 Gallon (UL) 1 6 LIQ -1.5 79694 AGENT - Ansulex Low PH Wet Chemical Agent, 1 0 1.5 Gallon (UL) 1 7 101-20 101-20 CARTRIDGE - Carbon Dioxide 101-20, 3 Gallon 1 0 Cartridge (R-102) 1 9 101-30 101-30 CARTRIDGE - Carbon Dioxide, 101-30, Double 1 0 Tank Cartridge (R-102) 1 10 TLINK TLINK LINK - Test Link Package 1 0 1 11 MICRO -SD MICRO -SD MICROSWITCH -Single Dual Electric Switch 1 0 1 12 HOSEGROMMET 418511 HOSE - Hose/Grommet Package 1 0 1 13 419337 419337 NOZZLE - 2W Nozzle, Dud 0 1 2 14 419336 419336 NOZZLE - 1W Nozzle, Duct/Appliance 0 2 10 16 419335 419335 NOZZLE - 1N Nozzle, Plenum/Appliance 0 10 4 18 419334 419334 NOZZLE - 1/2N Nozzle, Appliance 0 4 2 19 419338 419338 NOZZLE - 3N Nozzle, Appliance 0 2 1 22 419343 419343 NOZZLE - 2120 Nozzle, Appliance 0 1 4 25 418569 418569 NOZZLE ADAPTOR - Swivel Nozzle Adaptor 0 4 18 26 QSA-3/8 QSA-3/8 QUIK SEAL - 3/8" (UL) 0 18 1 27 QPSA-1/2 QPSA-1/2 PULLEY SEAL - 1/2" Hood Seal (UL) 0 1 7 28 S -DET S -DET DETECTOR - Series (Scissor Linkage) 0 7 http://appl.captiveaire.com/Order/FireSystems/PartsListReport.aspx?JobFireSystemld=144531 Page 1 of 2 Received Time May. 28, 9:59AM • a.VV NJ . V2 L.- 1'1 Page: 4 Nola — Fire Systems — Parts List Report 5/20/08 4:35 PM , 2 29 ANS-360FL ANS-360FL FUSIBLE LINK - 360deg F, R-102 and PIRANHA 0 2 5 30 ANS-500FL ANS-500FL FUSIBLE LINK - 500deg F, R-102 and PIRANHA 0 5 1 34 RPS -A RPS -A REMOTE PULL STATION - Aluminum (without 1 0 wire rope) 10 35 PE -LT PE -LT PULLEY ELBOW - Low Temp. Pulley Elbow, 10 0 Set Screw Type 1 36 PE -HT PE -HT PULLEY ELBOW - High Temp Pulley Elbow, 0 1 Compression Type 15 37 SS-SLV SS-SLV STAINLESS STEEL SLEEVE 0 15 7 38 ELB-90 ELB-90 3/8" CHROME PLATED ELBOW - 90 DEG 0 7 6 39 ELB-45 ELB-45 3/8" CHROME PLATED ELBOW -45 DEG 0 6 2 40 TEE TEE 3/8" CHROME PLATED TEE 0 2 3 41 SN -CHAR SN -CHAR SINGLE NOZZLE EXTENDED DROP ASSY 0 3 3 41 SN-CHAR30 DROPEXT-02 Extended Nozzle Drop -30" 0 3 http://appl.captiveaire.com/Order/FireSystems/PartsListReport.aspx?JobFireSystemld=144531 Page 2 of 2 Received Time May, 28. 9:59AM SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-28 REV. 5 4-1-06 Nozzle Application Chart The following chart has been developed to assist in calculating the quantity and type of nozzle required to protect each duct, plenum, or appliance. NOTICE This chart is for general reference only. See complete details for each type of hazard. Hazard Duct or Transition (Single Nozzle) Duct or Transition (Single Nozzle) Duct or Transition (Dual Nozzle) Electrostatic Precipitator (At Base of Duct) Plenum (Horizontal Protection) Plenum (Horizontal Protection) Plenum (Vertical Protection) Fryer (Split or Non -Split Vat) Fryer (Split or Non -Split Vat) Fryer (Split or Non -Split Vat)* Fryer (Non -Split Vat Only) Maximum Hazard Dimensions Length — Unlimited Perimeter — 50 in. (127 cm) Diameter —16 in. (40.6 cm) Length — Unlimited Perimeter —100 in. {254 cm) Diameter — 31 7/8 in. (81 cm) Length — Unlimited Perimeter -150 in. (381 cm) Diameter — 48 in. (122 cm) Individual Cell Length —10 ft. (3.1 m) Length — 6 ft. (1.8 m) Width — 4 ft. (1.2 m) Length — 4 ft. (1.2 m) Width — 4 ft. (1.2 m) Maximum Size (without drip board) 14 in. (36 cm) x 15 in. (38 cm) Low Proximity Maximum Size (without drip board) 14 1/2 in. (37 cm) x 14 in. (36 cm) Medium Proximity Maximum Size (without drip board) 15 in. (38 cm) x 14 in. (36 cm) High Proximity Medium Proximity Maximum Size (without drip board) 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity Low Proximity Maximum Size (without drip board) 18 in. (45.7 cm) x 18 in. (45.7 cm) High Proximity Minimum Nozzle Nozzle Quantity Heights 1 1 1 1 1 1 1 1 1 1 • For multiple nozzle protection of single fryers, see detailed information on Pages 4-12 through 4-14. 13-16 in. (33 — 41 cm) 16 — 27 in. (41 -69 cm) 27 — 47 in. 20 — 27 in. 21 — 34 in. 13-16 in. 25 — 35 in. (64-89 cm) Nozzle Part No. 430912 419337 419337 419334 419335 430192 419336 419336 419342 419342 419339 419340 419338 419342 419338 Nozzle Tip Stamping — Flow No. 1W 2W 2W 1 /2N 1N 1W 1W 1W 290 290 230 245 3N 290 3N Nozzle Application Chart (Continued) Hazard Fryer (Non -Split Vat Only)* Fryer (Split or Non -Split Vat) Fryer (Split or Non -Split Vat) Range Maximum Hazard Dimensions Maximum Size (with drip board) 21 in. (53 cm) x 14 in. (36 cm) (Fry Pot must not exceed 15 in. x 14 in: (38 cm x 36 cm)) High Proximity Medium Proximity Maximum Size (with drip board) 25 3/8 in. (64.4 cm) x 19 1/2 in. (49.5 cm) (Fry pot side must not exceed 191/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity Low Proximity Maximum Size (with drip board) 18 in. (45.7 cm) x 27 3/4 in. (70.5 cm) High Proximity Minimum Nozzle Nozzle Quantity Heights 1 1 1 Maximum Size (with drip board) 14in. (36cm) x 21 in. (53 cm) 1 Low Proximity Maximum Size (with drip board) 141 /2 in. (37 cm) x 26 1/2 in. (67 cm) 1 Medium Proximity Longest Side 1 32 in. (81 cm) Area — 384 sq. in. (2477 sq. cm) Longest Side 28 in. (71 cm) Area — 336 sq. in. (2168 sq. cm) Longest Side (High Proximity) 1 28 in. (71 cm) Area — 672 sq. in. (4335 sq. cm) Longest Side (Medium Proximity) 1 32 in. {81 cm) Area — 768 sq. in. (4955 sq. cm) Longest Side (Low Proximity) 2 36 in. (91 cm) Area —1008 sq. in. (6503 sq. cm) For multiple nozzle protection of single fryers, see detailed information on Pages 4-7 through 4-11. SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-29 4-1-06 REV. s 27 — 47 in. 20 — 27 in: 21 — 34 in. 13-16 in. 25-35 in. (64-89 cm) 13-16 in. (33 — 41 cm) 16-27 in. (41 — 69 cm) 30 — 40 in. (76 -102 cm) 40 — 48 in. (102 —122 cm) (With Backshelf) 40 — 50 in. (102.-127 cm) 30 — 40 in. (76 — 102 cm) 15 — 20 in. (38 — 51 cm) Nozzle Part No. 419339 419340 419338 419342 419338 419342 419342 419335 419333 419340 419341 419342 Nozzle Tip Stamping — Flow No. 230 245 3N 290 3N 290 290 1N 1F 245 260 290 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-30 REV. 3 10-1-02 Nozzle Application Chart (Continued) Hazard Griddle Chain Broiler* (Overhead Protection) Chain Broiler (Horizontal Protection) Gas -Radiant Char -Broiler Electric Char -Broiler Lava -Rock Broiler Natural Charcoal Broiler Lava -Rock or Natural Charcoal Char -Broiler Minimum Maximum Hazard Nozzle Dimensions Quantity Longest Side (High Proximity) 1 48 in. (122 cm) Area – 1440 sq. in. (9290 sq. cm) Longest Side (High Proximity) 1 30 in. (76 cm) Area – 720 sq. in. (4645 sq. cm) Longest Side (High Proximity) 1 36 in. (91 cm) Area –1080 sq. in. (6968 sq. cm) Longest Side 1 (Medium Proximity) 48 in. (122 cm) Area –1440 sq. in. (9290 sq. cm) Longest Side (Low Proximity) 1 48 in. (122 cm) Area –1440 sq. in. (9290 sq. cm) Longest Side – 34 in. (86 cm) 2 Area – 1088 sq. in. (7019 sq. cm) Length – 43 in. (109 cm) 2 Width – 31 in. (79 cm) Longest Side – 36 in. (91 cm) 1 Area – 864 sq. in. (5574 sq. cm) Longest Side – 34 in. (86 cm) 1 Area – 680 sq. in. (4383 sq. cm) Longest Side 24 in. (61 cm) 1 Area – 312 sq. in. (2013 sq. cm) Longest Side – 24 in. (61 cm) 1 Area – 288 sq. in. (1858 sq. cm) Longest Side – 30 in. (76 cm) 1 Area – 720 sq. in. (4645 sq. cm) Nozzle Heights 30 – 50 in. (76 –127 cm) (perimeter located) 30 – 50 in. (76 – 127 cm) (center located) 35 — 40 in. (89 – 102 cm) (perimeter located) 20 – 30 in. (51 – 76 cm) (perimeter located) 10 – 20 in. (25 – 51 cm) (perimeter located) 10 – 26 in. (25 – 66 cm) 1 – 3 in. (3 – 8 cm) 15-40 in. (38 –102 cm) 20 – 50 in. (51 – 127 cm) 18 – 35 in. (46 – 89 cm) 18-40 in. (46 – 102 cm) 14 – 40 in. (36 –102 cm) • Minimum chain broiler exhaust opening — 12 in. x 12 in. (31 cm x 31 cm), and not less than 60% of internal broiler size. Nozzle Part No. 419341 Nozzle Tip Stamping – Flow No. 260 419342 .290 419335/417332 1N/1NSS 419342 290 419343 419336/417333 419335/417332 419335/417332 419335/417332 419335/417332 419335/417332 419338 2120 1 W/1 WSS 1N/1NSS 1N/1NSS 1N/1NSS 1N/1NSS 1N/1NSS 3N Nozzle Application Chart (Continued) Hazard Minimum Maximum Hazard Nozzle Dimensions Quantity Wood Fueled Char -Broiler Longest Side — 30 in. (76 cm) 1 Area — 720 sq. in. (4645 sq. cm) Length — 32.5 in. (82.5 cm) 2 Width — 30 in. (76 cm) Length — 32.5 in. (82.5 cm) 2 Width — 30 in. (76 cm) 14 in. — 30 in. (36 — 76 cm) 1 Diameter 3.75 — 8.0 in. (9.5 — 20 cm) Deep 11 in. — 24 in. (28 — 61 cm) Diameter 3.0 — 6.0 in. (8 — 15.2 cm) Deep Upright Broiler Salamander Broiler Wok SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-31 3-1-O4 Ark). s Nozzle Heights 14 — 40 in. (36 — 102 cm) 35 — 45 in. (89 —114 cm) 30 — 40 in. (76 — 102 cm) Nozzle Part No. 419338 419334 419334 419341 Nozzle Tip Stamping — Flow No. 3N 1 /2N 1 /2N 260 419335/417332 1 N/1 NSS Assembly (3.0 gallon — Part No. 79290 cr 1.5 gallon — Par No. 79291) contains the regulated release mechanism, agem tank, expedient gas hose,for agent tank hookup. and enclosure knockouts to facilitate installing actuation, piping; expellani piping; detection system; and additional equipment. This regu- lated release assembly is used in single, double. and multiple - tank systems and must be mounted to a rigid -surface. The release mechanism can be used to interconnect both the actu- ation, and expellant gas lines as required per system design. The regulator is designed to allow a constant flow of gas into the tank at 100 psi (690 kPa) when the system is actuated: In single. double, and multiple -tank systems, the provided expel- lant gas hose connects the agent tank to the bottom outlet of the regulator. In double and multiple tank system configurations, the back outlet of the regulator is used as an expellant gas feed for one additional tank -enclosure or tank -bracket hookup. The enclosure contains the required knockouts to facilitate this con- nection. If a pressure switch is to be attached to the regulator, additional fittings are required. The tank is mounted within the enclosure. The tank contains an adaptor/tube assembly with a burst disc union: The burst disc helps prevent siphoning of the agent up the pipe due to signifi- cant temperature fluctuations in the area where the tank is located. The tank is mild steel and, under normal -conditions, requires hydrostatic testing every twelve years. - The agent tank is shipped uncharged and must be filled with 1.53 gallons (5.8 L) or 3.06 gallons (11.6 L) of -only ANSULEX Low pH Liquid Fire Suppressant during installation.. The detection and additional equipment required per system design are connected tothe release mechanism. The enclosure contains knockouts to facilitate detection and additional hookups. The system can bI actuated automatically or manually. Auto matic actuation occurs when a fusible link. within the detection system separates in a fire condition. Manual actuation of the system occurs when personnel pull on the remote manual pull station pull ring. EXTINGUISHING AGENT ANSULEX Low pH Liquid Fire Suppressant (1.5 gallon — Part No. 79694 or 3.0 gallon — Part No. 79372) is a potassium -based - solution designed for fast knock -down and suppression of grease -related fires. The agent is shipped in plastic containers which provide one complete tank charge. Agent storage life expectancy is twelve years. The distributor mtist record the batch numbers and date of shipment receipt to be filed with each instal- lation record. Total Tank Row No.* Quantity 1-5 1 6-11 1 ANSUL Type of System Type of Hardware Single 1.5 Gal. Reg. Release Single - 3.0 Gal. Reg. Release ELECTRICAL SWITCHES — LOC - p ft3 The electrical switches are intended for use with electric gas valves, alarms, contactors, lights, contractor- supplied electric power shut-off devices and other electrical devices that are designed to shut off or tum, on when the system is actuated. Switches are available -in kits: One Switch Kit, Part -No. 423878, Two Switch Kit, Part No. 423879; Three Switch Kit, Part No. 423880, and Four Swifdh Kit, Part No. 423881. Each switch has a set of single -pole, double -throw contacts rated at 21 amp, 1 HP, 125, 250, 277 VAC or 2 HP, 250, 277 VAC. Mounting hardware is provided with each kit. N.C. R-102 RESTAURANT FIRE SUPPRESSION SYSTEM (Standard UL 300 Listed) No=Ie Identification Chart Nozzle Nozzle Noz Nozz{e Tvoe Part No Sta moina Roy 1W Nozzle 419336 1W 1 1WSS Nozzle 417333 1W 1N Nozzle 419335 1N 1 1 NSS Nozzle 417332 1N 1/2N Nozzle 419334 1/2N 3N Nozzle 419338 3N 2W Nozzle 419337 2W 2WH Nozzle 78078 2WH 1 1/2 3 2 2 230 Nozzle 419339 230 2 245 -Nozzle 419340 245 2 260 Nozzle 419341 260 2 290 Nozzle 419342 290 2 2120 Nozzle 419343 2120 2 1F Nozzle 419333 1F 1 Itoo 147z4.E -3ogt2 Ileo Nitrogen Cartridge Required LT -20-R (7032) LT -30-R (5373) tt;%K71)1'1-1-0'. ` T 5 S -p 5 LL P;t fZ 5j r5 OT -c Carbon Dioxide Cartridge Required 101-10 (15850) 101-20 (17492) SECTION IX - APPENDIX UL EX. 3470 ULC CEx747 Page 9-1 7-1-98 REV. 3 SYSTEM SELECTION GUIDE NOTE: System options do not cover all conceivable variations. They are listed here as a general guideline to show the most common type arrangement for multiple systems, Based on certain system designs utilizirig manifolding, non-manifolding, 3 -tank systems, ► etc., other tank/cartridge combinations can be designed. The combinations below are based on 11 flow, 3.0 gallon tanks and 5 flow, 1.5 gallon tanks. More competitive designs may be available by utilizing 12 flow and 6 flow systems when appropriate. Total Tank Type of Nitrogen Flow No.* Quantity System Type of Hardware Carbon Dioxide Cartridge Required Cartridge Required 1-5 1 Single 1.5 Gal. Reg. Release LT -20-R(7032) ) 101-10 (15850) 6-11 1 Single 3.0 Gal. Reg. Release LT -30-R (5373) 101-20 (17492) 12-16 17-22 23-27 28-33 28-33 (Optional) 34-38 39-44 45-49 50-55 56-60 61-66 2 1.5 Gal. Reg. Release 3.0 Gal: Additional Tank Double Double Multiple Multiple Multiple Multiple 3 3 3 4 4 5 5 6 6 3.0 Gal. Reg. Release 3.0 Gal. Additional Tank 1.5 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Release (2) 3.0 Gal. Additional Tanks 1.5 Gal. Reg. Release • 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 3.0 Gal. Reg. Release 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 1.5 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 3.0 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 1.5 Gal. Reg. Release 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator' 3.0 Gal. Additional Tank Multiple 3.0 Gal. Reg. Release 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Double (73022) Double (73022) LT -20-R (7032) LT -A-101.30 (29187) LT -30-R (5373) LT -A-101-30 (29187) Double (73022) 101-30 (15851) 101-30 (15851)" 101-10 (15850) 101-30 (15851) 101-20 (17492) 101-30 (15851)" N/A Double (73022) 101-30 (15851) LT -A-101-30 (29187) 101-30(15851)"' Double (73022) LT -A-101-30 (29187) LT -20-R (7032) LT -A-101-30 (29187) LT -A-101-30 (29187) LT -30-R (5373) LT -A-101-30 (29187) LT -A-101-30 (29187) Double (73022) LT -A-101-30 (29187) LT -A-101-30 (29187) Double (73022) LT -A-101-30 (29187) LT -A-101-30 (29187) - Based on 5 flow numbers for a 1.5 gal. system and 11 flow numbers for a 3.0 gal. system. See Pages 4-39 - 4-42 for exceptions. 9 tanks are manifolded, only a "double tank" nitrogen cartridge (Part No. 73022) can be used. If tanks are manifolded, either an LT -A-101-30 nitrogen cartridge (Pan No. 29187) or a double tank cartridge (Part No. 73022) can be used. 101-30 (15851)" 101-30 (15851y- 101-10 (15850` 101-30 (15851)- 101-30(15851)*** 101-20 (17492) 101-30 (15851)*** 101-30 (15851)*'" 101-30 (15851) 101-30 (15851)- 101-30 (15851)- 101-30 (15851)- 101-30 (15851)*** 101-30 (15851)*** a ACCEPTED ❑ Without Comments As Noted In Red Per The Attached Letter i nese plans have been reviewed by The Tukwila Fire ; : vention Bureau for conformance with current city ,taildards. Acceptance is sub1ect to errors and ,.missions which do not authorize violations of adopted fanaaras and ordinances. The responsibility for the dequacy of design rests totally with the designer. =additions, delet;ons or revisions to these drawings atter this date will void this acceptance and wll require a I resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire, Prevention Bureau. Date: k / i7 0 By: -�07oV fUKWILA FIRE DE.PAtt f ivIG. . Please call: 575.4407, and give this job No.O 3 H ?- Ind exact address for shut. or restoration approval NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. 0 LL Zr J eN �O CCV� CO N O M O Lt. L.L. W W Q a u 66 66 a4 z J J • X O esi CO ▪ W M d tE n o !Aq n cc y N '5 LLi� ▪ C-_ a .9.).., e • E sl E C R. a) Q. 0 03 • Y O • E E• s C U p6 y E O)) c O a) a - ilt Y Q. m o « ° :1-_- « c a z •• 0 0 W _ N O — X7:4❑� 0 • o M Imo, • a) > teii •erIII o ° 03 ��,CD O C x I N of N rn w Q- T2 0 3 _ .0 :5- _v , 8 a 0 ti• b-' a 7 r� c m 0: 2 N00 01 ..... J 0) a6) C u. V) Y 43 0 2 a) 0 tel d C Q a) a) as g = E E ▪ a O t 03.0 Q C 0 0 O O m Q 0) 0 d C ■ s. ui F- 0 z a 03 a) s 0 0 U 03 U C 03 U E 03 a) a C V Nritnherof Pages (Including ('nvet) 01/21/2014 13:42 4254818695 FAX TRANSMITTAL CROWN FIRE PAGE 01/01 Fax No. CROWN FIRE PROTECTION, INC. Lam= 1.21.14 HIM Fine Prevention Bureau EOM Tukwila Fire Department / Al Dextro Permit 206.575.4439 a Wbri.A FIRE DEPARTMENT Ause call 206-575-4407 crtl Eiy2 this Fire Permit No. /`l -S -Oil and exit address for shut- down n or reaoration approval. 0 Urgent L1 For Review 0 Please Comment 0 Please Reply Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comment Please provide a demo permit to remove (4) sprinkler heads that are in the way of the flaming at the Ghipolte project at 2600 Southcenter Mall. The building permit # is D13-319.. Please let us know if you have any questions. Thanks— etaliCIATIPOTeNIIINALCY f1: PROTECTt0N SMtINK(,E1t SYSTEMS a i John J. Abel i ! 9760 -0591 -CG Laval Crown Fine Protection, Inc. C • NF 6.iMFwr�r��Nw+'.rima P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX 425.481.8695 a CHIPCYTI, CAN G 11,1d ......."' u�wwaa�aaw.an�x.,wmxat'';$ _.,.,, `4w.�,.....� _.�.�?a 4a:,,.,...., ...,..aA?t�'»:�»...� ,�r;a�Sk SHEET \U v1.3E� SHEET TITLE FIRE AI4IAI,M SADDITION K .ILA, ,°, 1.SHIN ;TSN FA -01 SYSTEM \FO ATI O \ FA -02 TYPICAL WI I\G A \D IVOU \TI \ G DETAILS FA -03 SYSTEM CALC U LATI O \ S A D SI\GLE LI\E DIAGAV FA -04 FRE ALAN SYSTEM FLA\ A :7741,774to d EE�� Without Comments Ci As Noted in Red Q. Per,The Attached Letter These plans have been reviewed by The Tukwila fire Prevention Bureau for conformance with current Cid ;tandards. Acceptance is subject to errors and ;:missions which do not authorize violations of adopted Landards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The, Tukwila Fire Prevention Bur u. Date: I LS I L By: QED SI -INDEX 4 completed, signed, Tukwila Fire Department Pre-test Certificate must be -presented to the Inspector prior to commencement of Acceptance Testing of any Fire Mann and Detection Systerls. Failure of test witl:rett in a Re -inspection Fee F termination of the t Tit.A FIRE DEPARTMETT call 206-575-4407 ard 45173 this Fire Permit NO. exact address for shut down CT • ULE ANI 'I IT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF..CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKED D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC - TWO ' •#16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKED S' STROBE CIRCUIT - RETURN TWISTED PAIR 1'A// SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEEDTWISTED PAIR #14 FPL/FPLR RED (JACKET) V' - SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.0. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSER\/ED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE 'NITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDAVT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 1 1 2 1 4 EX SYMBOL DESCRIPTION BPS TSM REMOTE BOOSTER EX POWER SUPPLY DUCT DETECTOR DUCT DETECTOR TEST SWITCH MODEL PAD -3 MANUFACTURER BACKBOX SIEMENS AD2-P W/ SIEMENS HFP-11 DET. TSM -1 SIEMENS PAD-3-ENCL DUCT HOUSING 1 -GANG BOX MOUNTING HEIGHT 66" A.F.F. TO TOP VERIFY IN FIELD VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD HT -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP BOX VERIFY IN FIELD S FIRE ALARM SPREAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2 EXTN EX FIRE ALARM JUNCTION BOX (EXISTING) F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND 121601 121701 12120) 22061 [ FcD JOHNNY 1FC141 F'C1J THAI CO 0 RETAIL IFC13J RETAIL TI ERVCE 1 FC61 / CAFE PHO ROOF ROOF T 'RACE CH I POTLE #2600 / STORE #2270 PAID JAM 13 2013 TUKWILA ARE WIRE DESIGNATION GENERAL NOTES SITE PLAN g'v RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE v 0 0 J J t zwc 0 0 cr' � F- 0 <C (' o J1 - J W Z W • O) W� O ,� a. LL 5))1.--D T (I 8 �-+ N ‘CALE: NOT 0 0 z DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 10/ 14 BACKROUND PLAN PROVIDED BY: Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER: 7692-1J SHEET FA -01} ij 120VAC-6CHZ - DEDICATED EMERGENCY THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC DEFRONSlUUiVDINO TD NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE - FROM XLS CONTROL PANEL l OR PREVIOUS ADDRESSABLE DEVICE J 0 O O HTRI-R ° 011 U 0 PAD -3 00 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 NOTE: SSEEEE ADDITIONAL DOCUMaENTATIONN.s C -CABLE C -CABLE (-) (+) (-) (+) SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) O❑ NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) O WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 :PUFPLR RED (JACKET) *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC , FOR ADDITIONAL SPECIFICATIONS SEE FRODUCT DOCUMENTATION. O 0 r GROUND 1© ©O I - 'I HTRI-R I B _ O o (+)> TO NEXT DEVICE OR ❑o _ 1.xrs: 1 m 0 1 1 0 DESCRIPTION ?� /. /."R' o 0 o ��1 T O 'E‘ (il B €la}. B � NAI I x - r" A BC DCC CII rA 8 « 1:11:1:111:1:1= In' rl:I 11:1:1= k-0,,, —mil I `'al I:I:I:I:I 11*' . C A 0 0 - _ o❑I (-) STOP IF LAST DEVICE DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL STROBE SPEAKER ❑o ❑OBJ UIHCUI1 �Qo SPARE SPARE (-) POWER SUPPLY & RELAY MODULE WIRING DETAIL FROM PRECEDING SPEAKER < OR FIRE ALARM CONTROL PANEL < (+) (+) (-) STROBE STROBE 1 ❑ o 11 O 1 m 0 li - 1 — DESCRIPTION SHOP DRAWINGS /. /."R' - 1 0 DATE 0 O O 'E‘ (il B B � NAI I - 8 « __ In' rl:I 11:1:1= I `'al I:I:I:I:I 11*' a A 0 0 - _ :;B,11( - 1 ❑OBJ UIHCUI1 �Qo SPARE SPARE (-) POWER SUPPLY & RELAY MODULE WIRING DETAIL FROM PRECEDING SPEAKER < OR FIRE ALARM CONTROL PANEL < (+) (+) (-) STROBE STROBE 1 ❑ o 11 O 1 m 0 0 1 DESCRIPTION SHOP DRAWINGS 0 DATE 0 ( 'o B B � NAI I - TIBC D[(Gx 11 « __ In' rl:I 11:1:1= NO ❑=1), VInVVl1 \Qo❑ ❑oD (-) (-) SPEAKER CIRCUIT (+) (+) STROBE CIRCUIT SPEAKERISTROBE Qo❑ I I () 0 0 I:I I:I:1'1 I:1:1 (+) (+) SPEAKER CIRCUIT SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS (+) STROBE CIRCUIT (-) r (+) ,\ (+) (-) SPEAKER CIRCUIT 5 TO NEXT APPLIANCE S OR 24K (EOLR) TO NEXT SPEAKER OR END OR LINE RESISTOR 24K (EOLR) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER 11N TEMPERA RE: +32' F (0' C TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR --> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) >- DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL HARD LID CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE > TO NEXT ADDRESSABLE DEVICE 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSION CEILING MOUNTED SPEAKER/STROBE 000 o ° eo 000 0 oo0 SPEAKER STROBE MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX ",' V..I �42,4i61i2 t,Iw 42.1r2M�',Iwi�O'Iw 4,21 t,IwieS4 s',IwPAK4,24.r wi ��Iwi+',Iwi�.421f4J1'4;wi• eO� JUNCTION BOX MOUNTED AGAINS CEILING SUPPORT SMOKE/HEAT DETECTOR TO NEXT DEVICE CADDY BAR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved rr) Co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-654.5 RELEASE/REVISIONS REV. BY: m 0 DESCRIPTION SHOP DRAWINGS DATE 0 0 I « J J CC 0 z U_ w W J 0 0 U N zw000 • T I— O CD z < JO Q W Z CC W CCw• � LU! w= CC LL 0 (ID J O cc SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:01 /10/14 BACKROUND PLAN PROVIDED BY: \ OB NUMBER: 7692-1} SHEET FA -02 ' ' N' , ,, I, „ .,„ , GRILL„,„ f FACPADONS Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS DATE Current Load: Standby: Alarm: Standby: MAlarm:‘ <<<<< ..:., . Device Type Qty Amps Total Amps Total Amps HFP-11 Amps 0.0022 0.0022 0.0023 0,000 . AD2-P 1 0.0635 0.0635 0.064 0.064 Main System Board HTR -RID 3 0.009600 0.0096 0.021 0.063 SET -MC -C ©15CD . ,' ' '',: :',15 - , 0.0875 1.313 SET -MC -C ©30CD 12 0.131 1.572 SET -MC -C @75CD, - , . 0.0731 Amps 0.127 Amps ,,,. e,. ! ' "„ ..;' „ .,„ , GRILL„,„ f EXISTING SIEMENS PAD -3 SignaI Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS DATE Z 0 0 J,.-rrer4,) yo4 " Standby: MAlarm:‘ <<<<< ..:., . ' • Device Type Qty Amps Total Amps Total , . . . Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -C ©15CD . ,' ' '',: :',15 - , 0.0875 1.313 SET -MC -C ©30CD 12 0.131 1.572 SET -MC -C @75CD, - , . . : 22g o. 1.332 SET -MC -C @95CD 0.292 . SET-MC-C,©iioco, , " ' .03.259 ‘• 1ZR-MC ©15CD 14 0.064 0.896 ZR-MC'©30PD ' , . '7 0.098 0.686 ZR -MC @75CD 0.175 . , . 0.03 . „ Amps ', 5.8285 Amps Standby Curnt Load: . .' :OA* Amps , For 24 Hours = 0.720 Amp -hours . Alarm Current Load: :: ' i' - :,• 5.8285 Amps ' „ Pot,5,,Mintite. '...,' 0.490 Amp -hours . „ . „ 25% Derating*. 1.512 Amp -hours . . ' . Total System Current Load: 1.512 Amp -hours . . ,. . Battery,Pair :be fUsed:'' ;x- I2VDC 4,.ke; ,.., .0.4 Notification Appliance Circuit Detail PROJECT: CHIPOTLE MEXICAN GRILL 1 1 . , .. ...._...._ .... .1 Panel: EXISTING PAD -3 POWER SUPPLY11/1/ire Resistance 2.58 : i Date: January 10, 2014 5 e"'el"fer,i?""if CURRENT TOTAL=1437.00 2 SET -MC -C ©15CD 1 87.51 175! 2 SET -MC -C ©36CD 131 ' 262 'SET -MC -C ©75CD 222[ , 0 ,SET -MC -C ©95CD 292 0 ZR -MC ©110CD 2591 0 i 7R -MC ©15CD ' 64 0 ZR -MC ©30CD 714 -MC 475CD DEV10ES=14 981 175 TOTAL mA= 1Total Wire Resistance ( R ) Total Device Load, Amps (1) !Voltage Drop ( E ) EOL Voltage 0 437 14 275 23.38 4371 .(WL* 2 )*(R/ft) 1 1.421 (Total Cct Load) 044 24 Notification Appliance Circuit Detail PROJECT: I CHIPOTLE MEXICAN GRILL Panel:IXLS-V 1Wire Resistance 2.58 Date: January 10, 2014 CURRENT TOTAL= 108.66 70.7V 1/8 70.7V 1/4 170.7V 1/2 0 70.7V DEVICES=142 1.81 41.4 3.54 67.26 01 0 TOTAL m A= !Total Wire Resistance ( R ) Total Device Load, Am 0) 1Voltage Drop ( E ) EOL VOltage • . 0 i08.661 „ „ 1 14 1,217 19.717645621 108.661 (WL*2 )*(R/ft) 6.28 :(Total Cct Load) 0 11 1(E= I * R) 1 0.681 (20.4:.•"! E), • 19.72 FAX (206) 628-4990 TEL. (206) 622-654-5 SYSTEM CALCULATIONS v,v. TO NEAREST EXISTING VOICE CIRCUIT (V2C) TO NEAREST EXISTING POWER SUPPLY (PS2C) TO NEAREST EXISTING DATA LOOP (DATA LOOP 2) ( D EX EOL S1 LOCATED ALONG THE CORRIDOR D S1-1 15cd v1-1 HT -R S1-2 1 5cd V1-2 D,I 1 HT -R 21 1 TSM S1-3 30cd V1-3 S,S' V,V' S1-4 30cd V1-4 1-117----1: FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. MONITOR MODULE TO MONITOR KITCHEN HOOD. RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE Z 0 0 <<<<< c\I cc c0„. 40 re W 1/4.:J 0 cc c-17 Z Ic":57) ;) 0 < <0 >t< Z CC I Luatt) 2 Z W CC w < Ouj 15 cC CL u_ cy)F- 8 c9 CC 00 w z w 0 z (/) 0 zz0 -J C.) Cin (i) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:01/10/14 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved .JOB NUMBER: 7692-1i I. SHEET FA -03 S1-4 30cd V1-4 i It i S1-1 15cd V1-1 111 L II 1-...�� ..-1 LJLJLJ S,SV,V1 s,s',v,V /: S1-3 30cd V1-3 .-m fj S S1-2 15cd V1-2 ri EX S,s',V,V' EOL S1 HT -R I �TSM I —c� _11.. Ell_Ell.13:11- .1 I_ _ J,_ FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. MONITOR MODULE TO MONITOR KITCHEN HOOD. Pro•rietar and Confidential, Co• ri•ht 2012 b Guardian Securit S stems, Inc. All Ri•hts Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 0og DESCRIPTION SHOP DRAWINGS DATE 01/10/14 2<a<aa 0 N woe co C.030cC (73 1-OOcs� < (4.5 U<�I- �z Wcc_ 2�1- J on �-Q = cc a. LLOI- o - o U N Z 4-CALE: 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 10/ 14 BACKROUND PLAN PROVIDED BY: �OB NUMBER: 7692-1} r- SHEET FA -04 ( SHARKY FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \ UV3ER SHEET TITLE FA -01 SYSTEM I \ FORMATION FA -02 TYPICAL DETAILS - WIRI\G A\3 N OU\TI\ G FA -03 FRE ALARM SYSTE VI FLOOR PLA\ FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLA\ WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BONG RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO 'CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C.;- AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED: BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES' IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR. TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ';ON FIRE ALARM: RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION, BOXES AND FRCP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL. BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME ` CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 30.5 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M -(4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD B Q LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN HELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING D DUCT SMOKE DETECTOR AD2-P W/ SIEMENS DUCT HOUSING VERIFY TSM MODULE IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXT. FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM SET -HMO -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. c FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING L FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXT. Q FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1 /2" EXT. TO BOTTOM B AWP FIRE ALARM STROBE (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. .B: F.B.O. VERIFY S IN FIEL JUNCTI❑N BOX F.B.O. 1~.B.❑, � I/ 'thout Comments • VERIFY ; IN FIELli, A.F.F. HDU V L f IIV1JflLL FL❑❑R IV/ H I •i/ H f r. As Not ' f i i Red ivi H MI °3 •- ' F- •-• -j- FURNISHED BY OTHERS N/A /A N/A N/A 'nese plans have been reviewed by The Tukwila Fire N/A NOT APPLICABLE N/A ,SPandards. Acceptancel�Aubiect to errors and N/A omissions which do not authorize violations of adopted LION. UNLESS OTHERWISE NOTED N/A }Mequacy of design rest4/tAtaiiy with the designNl/A Additions, deletions or revisions to these drawings atter WP WEATHERPROOF DEVICE N/A Hsubmittal of revised ditkilngs for subsequent 4.0ADval. ' ' '. A comp Fire [ RED AS BUILT ADD ❑R CHANGE N/A • - • •'- - . - __ • . - . , w-tthe Tukwila Fire, Prevehlti i Bureau. N/A i d ,,- AN 1 -- I IG to th Iilsn- GREEN AS BUILT RRMfVF N/A a e. ►if7M AIWO ___ Testir /A N/A - N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A 1 UKWILA FIRE DEPART:..Liit Please call: 575-4407 and give this job No.©? and exact address for shut' down or restoration approvall, 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS z DESCRIPTION SHOP DRAWINGS iu a 0 co 0 u-) 0 z C C VJ CC cc Q g Q NOTICE feted, signed, Tukwila )epartment Pre-test ate must be preserted e Inspector prior to Icement of AcceptE nce ig of any Fire Alarm Detection Systems. Failure of test will result in a Re -inspection Fee an i tcrlination of the testing. AI JUN 1120 Tukwila Fire ItD13'0 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved J SCALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: .OB NUMBER: SHEET �A THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE FROM XLS CONTROL PANEL OR r PREVI❑US ADDRESSABLE DEVIL STOP IF LAST DEVICE DUCT DETECTOR L❑CATION O END OF LINE DEVICE(3.GK 1/4W) SUPERVISED SWITCH O NI" m GROUND © © HTRI-R STATUS LED co (0 B 0 O N.O. COM N.0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE_ DEVICE TO NEXT ADDRESSABLE DEVICE L - NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX, CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX, LINE SIZE - MIN, LINE SIZE - MUSIC OUTLET SAMPLING TUBE INLET SAMPLING\ TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE f(+) STOP IF LAST DEVICE l(-) FROM XLS CONTROL PANEL OR f(+) PREVIOUS ADDRESSABLE DEVICE () RELAY CONTACTS (4.OA @ 125VAC) (4.0A @ 30VDC) 27 VDC 3,5 rmA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0,02uF 0,04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. 0 1001 TB1 5 0 0 0 0 123456 TB2 CP 654321 0 0 O N END OF LINE DEVICE 5 (3.6K 1/4W) O SUPERVISED____' SWITCH GROUND r) © © HTRI-D OSTATUS LED 00 0 O NOT USED CD 0 O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL Lia SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC _n 0 0 0 ED YT T U 0 0 PAD -3 0 CO O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 24K n TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END OF LINE DEVICE 3.6K 1/4W) \SUPERVISED 1 SWITCH ?NAC -4 NAC -3 NAC -2 NAC -1 ( FRONT NEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0 0 0 [FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS IW EOL INPU' P9 TSM -1 0 0 if 0 CC CO TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL FROM REMOTE POWER SUPPLY C'S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) SCALE NUE EARTH GROUND --)(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE + C (STR❑BE) SPEAKER (+) ( ) (+) ( ) STROBE () STR❑BE) (SPEAKER ) 0 SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80" A.F.F. 4S DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0PER�11N TEMPERATU E: +32' F (0' C) TO 100'F (38' C) HUMIDITY: O-93333332 RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE tDATA IN (-) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR ---- DB -11 STANDARD SMOKE DETECTOR BASE TO NEXT DEVICE< REAR VIEW >( ) DATA OUT I > (+) DATA OUT Jr HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING HARD LID --- ----- SPEAKER SUPPORT T ` - BRIDGE z 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTION BOX MOUNTED ON CEILING, FLEX / JUNCTI❑N BOX ----- MOUNTED AGAINST CEILING SUPPORT 0 0 FTS 1 TO NEXT DEVICE 0 0 ------ CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE=NONE SUSPENDED ILLUMINATED CEILING DO NOT INSTA_L ADDRESSABLE NITlATING DEVICES .,NAIL PREPROGAMMED WITH D=VICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All . Rights Reserved ca z 0,4 z 00 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS co W O I— `n Ln 1 _I CO Q CO 1- 2 (a 2(a (�WO - z E' W z cr cc = (1) Q =Qo3: (!) Ley c1 0 CO = tV I__ SCALE: 1 /8"=1 Z 0 0 z t� z 0 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: \OB NUMBER: SHEET FA -02 1 _\ --------------------------- ----- ---- -- f \\ 2C-3-2 110cd -r. 2S -= - 1 1 a 1 ' I 1 I ts ,' II 2C 1 V2 i. 2C-3-1 110cd NORTH I • it �\ -;8 i1 25,2V 1 jJel /71 HARKY'S m--2S,2V mrr 2S 2V E D,2S,2V 2C -2- I ///::// V2C- 1 QD- 2 U 2V FLAG NOT 2C-1-1 15cd V2C-5 ,2V EOL—S1 20.34V 2C-1-3 15cd V2C-7 s,v S 2 S 2 1� 15cd V2C-12 S,2V SHARKY'S WESTFIELD SOUTHCENTER MALL SCALE 11811=1' 2-53 PS2C o -D 2C -3 1 d V2C-14 FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM, FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. DO NOT INSALL ADDRESSABLE IN DEVICES U\TIL DREPROGRAMV DEVICES ADDS T ATING ED W ;ss. H Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ro co ® ON it Z O Z zCII3 w_ LIU < Iii a LLI6 Itio '-" C4 w•I N Ll_I N Ct Q IS (/) I- O - N NW Ca - W - I- FAX (206) 628-4990 RELEASE/REVISIONS m W DESCRIPTION SHOP DRAWINGS LU co 0 O z C C J uJ Q�(/) T O) w �o UZ ite r2c ce4q EC !!= Q u) vJ W NJ o op CV 11.1 SCALE: 1 /8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: .OB NUMBER: C SHEET FA -03 / / L41.1 SYSTEM CALCULATIONS ---- ---_- ---- 0 0 1 _ }3'> 3" - - ," 1 l l 1 N ! 1 NORTH ------------ 0 0 1 \k\ , 0 1 ‘k: x +-"mo-21\-1 111 , \-1-‘ l� / 11 PTV, SHARKY'S WESTFIELD SOUTHCENTER MALL \ , j - �> �i SCALE 1/32'=1' 2S,2V b, 30 FA -BOX FACP BATTERY SIZING CALCULATON SHARKY'S SHARKY'S Detail FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations PROJECT: Panel: SHARKY'S Wire Resistance 1.62 Date: June 10, 2008 CURRENT TOTAL 98 CIRCUIT: Current Load: Standby: Alarm: Current Load: Standby: Alarm: Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 0 SET -MC @15CD 64 0 Device Type 0.62 Qty Amps Total___ Amps Total Device Type Qty Amps Total Amps Total 0 HFP-11 0.0022 0.0022 0.0023 1 0.10 0 SET -MC @110CD 233 0 AD2-P 0 0.0635 0.0635 0.064 Main System Board 1 0.03 ( E) 0.03 0.030 0.030 445 HTR -R 0.009600 0.0096_ 0.021 (E= I * R) SET -MC @15CD SET -HMC @135CD 318 0 0.064 HTRI-D 20.34 0 0.001600 445 0.0035 SET -MC @30CD 1 (20.4 - E) 0 0.098 0.098 0 ICP -B6 0.005 0 SET -MC @75CD 98 0 0.175 0 SET-MC-CW@110CD 233 0 SET -MC @110CD DEVICES= 1 0.233 98 12 191 20.339353681 981 Notification Appliance Circuit Detail SET HMC-C@115CD PROJECT: WESTFIELD SOUTHCENTER MALL 0.318 Panel: SHARKY'S Wire Resistance 2.58 Date: SET HMC-C@135CD CURRENT TOTAL 1.8 CIRCUIT: SPEAKER CIRCUIT 0.318 QTY 0.0731 Amps Alarm Total Amps SET HMC-C@185CD Voltage at EOL Circuit Total 1 70.7V 1/8 1.8 0.445 Total Wire Resistance (R) 0.99 0 0 0 ZR -MC @15CD (WL*2)*(R/ft) 0 0 0 0.064 Standby Current Load: 0 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 0 0 0 0.098 Voltage Drop �J ( E) 0.00 0 0 0 HCP 0 0 0 0.0015 EOL Voltage 20.40 Alarm Current Load: 0 Amps For 5 Minutes= Amp -hours 1 (20.4 - E) 0 0 0 0.03 Amps 0.128 Amps 0 0 DEVICES= 1 TOTAL mA= 1.8 14 191 20.39822599 1.8 25% Derating= 2.193 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.128 Amps For 5 Minutes= 0.011 Amp -hours Total System Current Load: 2.193 Amp -hours 25% Derating= 0.913 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 0.913 Amp -hours Battery Pair to be Used: 12VDC 1 Amp -hours 7AH BATTERY SIZING CALCULATON 1743 IST TEL. (206) 622-6545 RELEASE/REVISIONS z a DESCRIPTION cn z a 0 a. 0 w co 0 1n LO 0 z 0 LU O LU C) e co CC J co <T- caJ 2 wit z �C WRQ CC () z� LLI UZ CC CC II LU = < co> (!) 0 C) J U W VJ \ SCALE: 1 /8"=1 DRAWN BY: I.ANDERSON DESIGNED ' BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: \ 0B NUMBER: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -04,, WESTFIELD SOUTHCENTER Notification Appliance Circuit MALL Detail PROJECT: Panel: SHARKY'S Wire Resistance 1.62 Date: June 10, 2008 CURRENT TOTAL 98 CIRCUIT: S1 QTY Device Type Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 0 SET -MC @15CD 64 0 Total Wire Resistance (R) 0.62 1 SET -MC @30CD 98 98 0 SET -MC @75CD 175 0 Tota Dev Device Load Amps 1 0.10 0 SET -MC @110CD 233 0 (Total Cct Load) 0 SET-HMC-C@115CD 318 0 Voltage Drop ( E) 0.06 0 SET-HMC-C@177CD 445 0 (E= I * R) 0 SET -HMC @135CD 318 0 EOL Voltage 20.34 0 SET -HMC @185CD 445 0 (20.4 - E) 0 Z-MC@15CD 64 0 0 Z-MC@30CD 98 0 0 SET-MC-CW@110CD 233 0 DEVICES= 1 TOTAL mA= 98 12 191 20.339353681 981 Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: SHARKY'S Wire Resistance 2.58 Date: June 10, 2008 CURRENT TOTAL 1.8 CIRCUIT: SPEAKER CIRCUIT QTY Device Type Alarm Current Alarm Total Wre Size Wire Length Voltage at EOL Circuit Total 1 70.7V 1/8 1.8 1.8 Total Wire Resistance (R) 0.99 0 0 0 (WL*2)*(R/ft) 0 0 0 Total Device Load, Amps (I) 0.00 0 0 0 (Total Cct Load) ll 0 0 0 Voltage Drop �J ( E) 0.00 0 0 0 (E=I*R) 0 0 0 EOL Voltage 20.40 0 0 0 1 (20.4 - E) 0 0 0 0 0 0 DEVICES= 1 TOTAL mA= 1.8 14 191 20.39822599 1.8 1743 IST TEL. (206) 622-6545 RELEASE/REVISIONS z a DESCRIPTION cn z a 0 a. 0 w co 0 1n LO 0 z 0 LU O LU C) e co CC J co <T- caJ 2 wit z �C WRQ CC () z� LLI UZ CC CC II LU = < co> (!) 0 C) J U W VJ \ SCALE: 1 /8"=1 DRAWN BY: I.ANDERSON DESIGNED ' BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: \ 0B NUMBER: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -04,, 1; APPROXIMATELY 850 SF oil 1.41 toss r l :.:\ OM Sal SE"VING 103 Li .. .... t POs 1 �t 101 -� (sr'ti ��� °KING!�.. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS f=ire City j' i'? ::()opted •''n -atter 1 1. TCHEN LIT .tz ,Q FIRE PROTECTION PLAN 1/4" = 11-0" 1j E ........... .__ .._..I+ .l ii 1 IE:- -. ,L ° ...._._....._......... .... .__ ' iit Emu ma raw En as Assn li FO-514,DCi COOLER- 1 1 1 1 1 Design per NFPA 13, Ordinary Hazard Group 2, Retail — 130 Sq, Feet Max All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 14 — Reliable Model G5-56 165° Standard Response Pendents 1/2 x 1/2 (concealed white) A 1 — Globe Model GL5635 200° Quick Response Dry Pendents 1/2 x 1/2 - i• i uI arra inspection byj 51( WASHINGTON STATE CERTIFICATE OF COMPETENCY . FIRE PROTECTION SPRINKLER SYSTEMS John J. Abel 9 60 -0591 -CG Level 3 wn Fi Protection, Inc. k- CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113. MILL CREEK, • WASHINGTON 98082-0113 PH. (425) 481-7669 12/3111.4 4 �ti.4 STORE # 2270 Southcenter Mall 2600 Southcenter Mali, FC -2 Tukwila, WA 98188 JA TUK` .PAID 93 .%nett ILA FIRE 20 ? 5% DATE: 1v wry TJ CHIPOTLE.n 1 ,. / CHIPOTLE �_ A IIIA IP' ..�.. „,.4,_1166 ill 17:= \ rYw'I . ii i, a.: I ' "' pI 2600 SOUTHCENTER MALL ' ICSTM 1 I esusiw..a !Manr+...ti CIITY JIMAP ® ®O KEY PLAN SG& NDTTo9CV.E - moo stat NorfO5C.0 . CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113. MILL CREEK, • WASHINGTON 98082-0113 PH. (425) 481-7669 12/3111.4 4 �ti.4 STORE # 2270 Southcenter Mall 2600 Southcenter Mali, FC -2 Tukwila, WA 98188 JA TUK` .PAID 93 .%nett ILA FIRE 20 ? 5% DATE: 1v VICINITY MAP (Suite#2600 FC -02) SCALE: NTS General Notes 1. Western States Fire Protection to add new pendent heads new and branchlines in new tenant space. Sprinklers in the new store shall be spaced lin accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of alt sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only jn the ares of work. All other areas are not in contract and WSFP is not responsibly for existing conditions. I23E3r173 13 on EXISTING PIPE NEW PIPE SYMBOL LEGEND EAST RISER DETAIL HYDRAUL-IC REFERENCE ONLY NOT TO SCALE REVISIONS 1 1 J 1 1 1 1 1 1 1 1 i1 1 J ----- Ordinary Group II.0.200gpm/ft2 for 743.O0ft2 CEILING HEIGHT TO BE 14-0" AFF UNLESS OTHERWISE NOTED SHARKY'S Remote Area: Retail # 2600 FC -02 k CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II IMAX. COVERAGE per HEAD 130 FP t DENSITY .20 GPM l Ft' for 743 FN SPRINIQER Reliable Model G4A/ F1FR (ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER. SYSTEM REQUIRES: _GPM(5'9.7 PSI SHARKY'S FC -02 - TI Sprinkler Legend • At lime of Design 2 -WAY EARTHQUAKE BRACE ND. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR.IMODEL 3 5 7 9 11 .:TYPICAL FLEXABLE SPRINKLER CONNECTION: MOUNTING BRACKET SPRINKLER HEAD FLEXHEAD DETAIL NOT TO SCALE, FIG. E09 SWIVEL SWAY BRACE FITTING BRACE PIPE 318" KWIK BOLT (2 IW EMBED LENGTH) FIG.IODO - "FAST CLAMP" SWAY BRACE ATTACHMENT LINE PIPE LATERAL LINE RESTRAINTS NON•THREADED BRACE PIPE FIG.4A PIPE CLAMP FOR SWAY BRACE 3/B" KW I K BOLT (21/4' EMBED LENGTH) FIG.909 NO -THREAD SWIVEL SWAY BRACEATTACHMENT i LATERAL BRANCHLINE RESTRAINT BRACE PIPE 5iunfnl NON•THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt IH Cut Rod Lgth Rounded to Nearest Inch Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE FILE COPY 00 Without Comments A5 Noted In Lied Per The Attached Letter 1 nese plans hav I, ;,:r1 reviL:v'rd by Til; Tu,;qib Fire Prevention'iI..Iri_,au. I:C:, fro! !li;,l'iCi? 1'•1:�i1 CU(te?;lt CitV standards. .;,.c;.4t ,..-•nL::: is r+: 0lUro ni.:(t OmISSi011S 41?lic:i) no r.., el.i`?•'i;i...., ,itC C,: ..:.;,iopi:E3d stanaards EII d .. .... >.,,-� h:; fc ,r .. ,I, :;t,: ,:.r the adequady :,)i . .il. ,mill ,,,, _,.aril ilia. /Additions, di:. i'. A,; ti iUS(i dr:.,i igs atter this date will'.o' l.hi.; [/,.:o:pi 1:ICe r,,,rd will require a • resubmittal of revised drawings foe subsequent approval. Final acceptance k subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: ,S -`ani -02 .By: VICINITY MAP DETAIL NOT TO SCALE UKWILA FIRE DEI -'AR I Mt;�fvs Please call: 575-4407 and give this job No. b$-5-)}3 lira* and exact address for shut' :sown or rest.aration approval. OTECE Weld stamps must be inspected before pipe is hung. 1.2p not paint piping prior to hydrostatic test approval. PAID E".'': 3 2 3 2008 Tukwila Fire �Tltop `S U z WESTWOOD CONTRACTORS • I- 0 0 0 APPROVAL: CITY OF TUKWILA 4 -WAY EARTHQUAKE BRACE 6 5.6 Pendent Brass 212°F REL G4A HYDRAULIC REFERENCE POINT R5415 4 5.6 Pendent Brass 155°F REL G4A CONT. NO.: K$0414 HANGER SYMBOL R615 5 5.6 Pendent Chrome 155°F REL F1FR SSP DRAWN BY: C. ISAAC BRANCHLINE RESTRAINT 2 5.6 Pendent w Brass 286°F VIK M STD ADJ QR DRY SPRK. ON SHEET: SEE LEGEND Total =17 SPRK. ON JOB: DATE: 05/23/08 Western States Fire Protection Company 7102180th AVE NE, STE A-105 - REDMOND, WA- 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS( DECATUR/DENVER/DULUTH/HOUSTON/KANSAS CITY LAS VEGAS IMINNEAPOLIS / PHOENIX/PORTLAND 1 RAPID CITY)ST. PAUL/SALT LAKE CITY /SEATTLE Phone:425-881-0100 Fax:425-881-3030 S HARKY'S 2600 SOUTH CENTER MALL FC -02 TUKWILA,WA 98188 SHARKY'S FC -02 TI SHEET FP -1 OF 1 SHARKY'S FC -02 lirjTa .4 11le Nraj ��� IO�. ylll lE �� ,tai _ �-',,,,"'' I1I0I��nP'��I 1111 �! I L ':. IIS •� ice',! 1�atiu ���11�1masi el _ iii iii ii MN 011 �1 _- fraraW 1 111, ow A, ^ immil i olaii 11aalga `. 1rlr-6 General Notes VICINITY MAP (Suite#2600 FC -02) SC:ALt: N 15 1. Western States Fire Protection to add new pendent heads new and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The buildina is constructed with non-combustible materials and aualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA. as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for free7ind conditions 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. EXISTING PIPE El NEW PIPE Eg EAST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE (?o swam'® �'� ® tee: 1.6 ®A r .s4300.2. ' ■L DN1x9' 8'-0" AFF d'?� o , A1.02 001.0 8-1 AFF ®A..I 1'-9 • 1 05 DN1xs:rb 0 •u .1.11 o? 10'-8' • 10'-0 AFF H ct 10'-G AFF ,`:` �• o q WALK IN COOLER_Usti p . • 1 nrf to \ e K" 'S p 6 �i �N .2,+ �.T' .0. 4' m.0 i� St fD 0 r c N 0t.,„' 107 10'-0 AFF 0 II CM 1'-3 '- CEILING HEIGHT TO BE 14 -0" AFF UNLESS OTHERWISE NOTED SHARKY'S RemDte Area: Retail # 2600 FC -02 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Fc' DENSITY .20 GPM / Ft' for 743 Ft' SPRINCLER Reliable Model G4A/ F1FR ORIFICE 1/2° K. 5.6 WATER FLOW INFORMATION*: STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 358.4 GPM CI 58.7 PSI SHARKY'S FC -02 - TI " At time of Design TYPICAL FLEXABLE SPRINKLER CONNECTION": • FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLIKE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE FIG.909 SWIVEL SWAY BRACE FITTING OI 318' KWIK BOLT (2 IW EMBED LENGTH) FIG. 1000 "FAST CLAMP" SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE FIG. 4A PIPE CLAMP FOR SWAY BRACE 318' KWIK BOLT (2I/4' EMBED LENGTH) FIG.909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT LATERAL BRANCHLINE RESTRAINT lag] NON•THREADED BRACE PIPE LATERAL BRANCHLIKE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III Rod Coupling —� cut Rod Loth Rounded to Nearest Inch Q All Thread Rod CL Swivel Ring Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE w 0 WESTWOOD CONTRACTORS INC CONTRACTOR. SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE 6 5.6 Pendent Brass 212°F REL G4A APPROVAL: CITY OF TUKWILA HYDRAULIC REFERENCE POINT R5415 4 5.6 Pendent Brass 155°F REL G4A CONT. NO.: KS0414 R615 5 5.6 Pendent Chrome 155°F REL F1FR SSP DRAWN BY: C. ISAAC HANGER SYMBOL 2 5.6 Pendent Brass 286°F VIK M STD ADJ QR DRY BRANCHLINE RESTRAINT Total = 17 SPRK. ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 07/21/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE /AUSTINI DALLAS I DECATUR / DENVER / DULUTH / HOUSTON /KANSAS CITY LAS VEGAS l MIIWEAPOLIS / PHOENIX / PORTLAND, RAPID CITY/ ST. PAUL /SALT LAKE CITY/ SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 SHARKY'S 2600 SOUTH CENTER MALL FC -02 TUKWILA,WA 98188 SHARKY'S FC -02 - TI SI!EET FP -1 OF 1 2600 SOUTHCENTER MALL FC -2 FOOD COURT ASSOCIATED PERMITS 14-F-006 08-F-321 14-S-015 14-S-011 08-S-238 14-H-021 08-H-266 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address: 2600 Southcenter Mall FC -2, 98188 Suite Number: 2270 Floor: Tenant Name: Chipotle Mexican Grill New Tenant? Q - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address: 1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City E-mail Address: Fax Number:206.628.4990 State Zip Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): ✓ i v Scope of Work (please provide detailed information): Adding 9 devices to existing FRCP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O NER OR ALJTHO Z D AGENT: Signature: Date: Print Name: Karina Veliz < Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 4431t*1144 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: ? Qt �C7ZA1 teri'er Ma- a- I) Suite Number: ":2. Floor: Tenant Name: CY\ TO 1 - Property Owner's Name: W e�k-c1- ' pnaiXsenne !-T New Tenant? ❑ - Yes -No Mailing Address: CONTACT PERSON -if there are questions about the submittal. Name: Company Name: Mailing Address: City Crown 1 \vim %-vec+\c 11 State Zip Day Telephone: 2 25 14R1 1 "7 CA69 City State Zi E-mail Address: e . �\C Q o (rO L v . COYY\ Fax Number: L2-\ �vc S Total number of new/relocated devices or sprinkler heads: (—,5� Valuation of Project (contractor's bid price): $ —7, Ce Scope of Work (please provide detailed information): osy ark POA %-y\ofilcc> PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 4 j 2OR AUTHORIZED AGENT: JJ j Signature: Z 9-r 1 . Date: /23 �! / Print Name:</C-�S5lt'2 150 /12SOn Day Telephone: Q75' /' -7( Plan Permit App.doc 1/2/13 TFD FP Form 8 OW SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: Z(, 0 0 50 tcrvi Gg 4 6 R. M4 1. -1 --- Tenant Name: C N t P OT Le - New Tenant? ['Yes ❑ - No Property Owner's Name: *S-rFI --D 1a07CRTI -"AX 6Pi-, King Co. Assessor's Tax No.: Suite Number: FC- - 2 -Floor: Mailing Address: ?o Sc( I3 oR4 O CARA-54349 City CONTACT PERSON -if there are questions about the submittal. Name: -.AY 5ci-tNEBC-'t Company Name: Mailing Address: J,ScArNeto ►rtkoo8 cow► Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ i ✓ e Scope of Work (please provide detailed information): t100 t- LAP ?R.6 - Pt -U P keD WEsST crt6 ' IG4L P A J -- 5yS EM lAJ kr z- (7N QA/J((6 t}oo'D E-mail Address: �a 9' 20 State Zip Day Telephone: 20(0 .72_6 09 4 U RAT Hoop eat) D ta.cC- ;r: 2v I S 1 t rC - (, (o o (V-1* Ave S. SEA True City WoN 9'g Ib ' State Zip Fax Number: 7-0(0 To 1 2J O "] PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Ja j Se., J 6 c.x Plan Permit App.doc Date: 1/77 12-01t4 Day Telephone: 2-0 Co ` 7 ZCo ' O 9 4 O 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Sharkey's 2600 Southcenter Mall FC -02 Permit No.: 08-S-238 Date: May 29, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/z inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Sharkeys 2600 Southcenter Mall space FC -2 Permit No.: 08-H-266 Date: June 4, 2008 Reviewer: Steve Kohler Fire Protection Inspector/Plan Review (206)575-4407 • Nozzle heights above appliances to be per manufacturers installation guidelines. • Install splash guards between fryers and ranges/charbroilers. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Chipotle Mexican Grill 2600 Southcenter Mall FC -2 Permit No.: 14-S-015 Date: February 4, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods Tess than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 % inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Chipotle Mexican Grill 2600 Southcenter Mall FC-2Pb Permit No.: 14-H-021 /4 Date: February 6, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Nozzle heights above appliances to be per manufacturers installation guidelines. • Fryers shall be installed with at least a 16 inch space between the fryer and surface flames from adjacent cooking equipment or a minimum 8 inch high steel or tempered glass baffle plate shall be installed between the appliances. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust system whenever cooking operations occur. The activation of the exhaust system shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. • A minimum 110 candela horn/strobe shall be installed above the kitchen hood suppression system manual pull station at a height of 80 inches above the floor. • A separate fire alarm permit from the Tukwila Fire Department is required for all fire alarm work. • The suppression system manual pull station shall be located no closer than 10 ft. and no farther than 20 ft. from the cooking equipment and be placed at a height of 42 to 48 inches above the floor. • The inside lower edge of the hood shall overhang or extend a horizontal distance of not Tess than 6 inches beyond the edge of the top horizontal surface of the appliance on all open sides. The vertical distance between the front lower lip of the hood and such surface shall not exceed 4 feet. • If cooking appliances are wheeled, the appliance wheels shall be set in tracks permanently mounted to the floor to ensure appliance is returned to original location if moved for cleaning or maintenance. Hydraulic Overview Job Number: KS0414 • Job Job Number Design Engineer KS0414 CHRIS J. ISAAC Job Name Phone FAX SHARKY'S 206-491-6679 425-881-3030 Address I State Certificabonticense Number 2600 SOUTH CENTER MALL FC -02 WESTESF136QF Address 2 Aryl CITY OF TUKWILA City State Zip Code Job Site TUKWILA WA 98188 SOUTH CENTER MALL System Density Area of Application 0.200gpm/ft2 743.00ft2 (Actual 742.22ft2) Most Demanding Sprinkler Data Hose Streams 5.6 K -Factor 20.70 at 13.664 250.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 103.50ft2 15 System Pressure Demand System Flow Demand 65.822 358.39 Total Demand Pressure Result 608.39 @ 65.822 • +73.601 (52.8%) Supplies Check Point Gauges Node Fiow(oom) Hose Fiow(opm) Static(psi) Residual(osil Identifier Pressure(psi) K-Factor(K? Flow(oom) 1 10900.00 250.00 140.000 20.000 Cillis 410. 1 i t. //1 SHARKY FP-1.cad Supply at Node 1 (10900.00, 250.00, 140.000, 20.000) 150 _ 135 Static Pressure i 140.000 120 R wij�s1 105 4,_s A 90 _ .N a F- 75 y,608.39 wi h hose streams -""t ;v 60 358.39 @ 65 822 I; a 45 11 11 il "' 30 System demand curve [ — — — — -- 15 10900.00 @ 20.000{ E. 0 X11111111111111111111 111111 111 111111111 1111111111 111111111 1 1 1 1 1 1 1 1 1 111111111 11P 33000 5500 66007700 8800 990011000 Water flow, gpm © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 05/23/2008 3:19:OOPM Page 1 Hydraulic Summary •Job Number: KS0414 Job Job Number KS0414 Job Name SHARKY'S Address 1 2600 SOUTH CENTER MALL FC -02 Address 2 City State Zip Code TUKWILA WA 98188 Desgn Engineer CHRIS J. ISAAC State CertificabonlLicense Number WESTESF136QF AHJ CITY OF TUKWILA Job Site SOUTH CENTER MALL Drawing Name SHARKY FP-1.cad System I Remote Area(s) Most Demanding Sprinkler Data 5.6 K -Factor 20.70 at 13.664 Hose Allowance At Sauce 250.00 Additional Hose Supplies Node Flow(gpm) Occupancy Ordinary Group II Density 0.200gpm/ft2 Number Of Sprinklers Calculated 15 Area of Application 743.00ft2 (Actual 742.22ft2) Coverage Per Sprinkler 103.50ft2 Total Hose Streams 250.00 System Flow Demand Total Water Required (Including Hose Allowance) 358.39 608.39 Maamum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 20.36 between nodes 529 and 537 Maximum Velocity Under Ground 1.35 between nodes 1 and 1371 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 3530.90gal 10.09gal Supplies Hose Flow Static Residual @ Flow Node (gpm) (psi) (psi) (gpm) Available @ Total Demand (psi) (gpm) Required Safety Margin (psi) (psi) 1 250.00 140.000 20.000 10900.00 139.424 608.39 65.822 73.601 Contractor Contractor Number KS0414 Contractor Name Western States Fire Protection (Redmond) Address 1 7102 180th Ave NE, Suite A-105 Address 2 City State Zip Code Redmond WA 98052 Contact Name Chris J Isaac Phone (425)881-0100 FAX (425)881-3030 E-mail chris.isaac@wsfp.us Web -Site Contact Title Designer Extension !� ©M.E.P.CAD, Inc. ?s AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:24PM Page 2 1 .411 Summary Of Outflowing Devices Job Number: KS0414 Report Description: Ordinary Group II Device Sprinkler Sprinkler Sprinkler Sprinkler r* Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler Sprinkler 115 102 103 106 101 104 105 110 107 109 111 108 114 112 113 Most Demanding Sprinkler Data Actual Flow Minimum Flow K -Factor Pressure (gpm) (gpm) (K) (psi) 29.78 20.75 20.84 23.83 20.70 20.93 22.14 24.14 23.99 24.10 24.25 24.08 28.68 25.09 25.11 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 20.70 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 28.273 13.733 13.845 18.101 13.664 13.966 15.633 18.577 18.348 18.522 18.747 18.486 26.228 20.077 20.100 1, © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:25PM Page 3 Node Analysis Job Number: KS0414 Report Description: Ordinary Group 11 Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 472 15'-9 P0(8c0) 38.251 480 18'-9 P0(5'-0) 36.009 498 17-9 T(5'-0) 15.940 504 17'-9 T(5'-0) 15.198 529 15'-9 P0(8'-0) 38.254 537 17'-9 P0(5'-0) 22.662 538 17'-9 PO(5'-0) 19.680 540 17'-9 P0(5'-0) 18.664 542 17'-9 E(2'-0) 18.184 638 15'-9 P0(8'-0) 38.319 673 17'-9 P0(5'-0) 23.522 646 17-9 PO(5'-0) 23.241 647 17-9 PO(5'-0) 2t933 651 17'-9 E(2'-0) 21.111 652 ' 18'-3 2T(5'-0) 19.247 703 14'-3 P0(8'-0) 39.493 712 17'-9 PO(5'-0) 28.415 714 17'-9 E(2'-0) 27.710 767 17'-9 T(5'-0) 24.287 1191 18'-3 2P0(26'-4) 42.497 1290 -16'-1 P0(37'-8%) 58.597 1371 -14'-1' BFP(-4.500) 62.352 1405 -16-1 LtE(16'-0) 58.652 115 10'-63 Spr(-28.273) 28.273 102 7-0%4 Sp (-13.733) 13.733 103 8'-0%4 Spr(-13.845) 13.845 106 10'-6%4 Spr(-18.101) 18.101 101 10'-O% Spr(-13.664) 13.664 104 7-0%4 Spr(-13.966) 13.966 105 10'-6V4 Spr(15.633) 15.633 110 10'-6%4 Spr(-18.577) 18.577 107 10'-0% Spr(-18.348) 18.348 109 10'-6%4 Spr(-18.522) 18.522 111 10'-6%4 Spr(-18.747) 18.747 108 10'-0%4 Spr(-18.486) 18.486 114 10'-0% Spr(-26.228) 26.228 112 10'-0%4 Spr(-20.077) 20.077 113 10'-0%4 Spr(-20.100) 20.100 1 -22'-0 S 65.822 29.78 20.75 20.84 23.83 20.70 20.93 22.14 24.14 23.99 24.10 24.25 24.08 28.68 25.09 25.11 358.39 (, © M.E.P.CAD, Inc. ,;;.4 AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:25PM Page 4 1 Hydraulic Analysis Job Number: KS0414 Report Description: Ordi Pipe Type Downstream Upstream Diameter Elevation Flow Discharge Velocity K -Factor HWC Pt Friction Loss Length Pressure Pn Fittings Eq. Length Summary Total Length = Route 1 DR 1.0490 Q=20.70 7.68 C=120 0.1386.82 29'-7% Pf 5.630 101 10'-0% q=20.70 K=5.6 13.664 Spr(-13.664) 11-0 Pe -3.354 498 17'-9 15.940 3E(2'-0), T(5'-0) 40'-7% Pv BL 1.0490 Q=41.54 15.42 C=120 0.503015 2'-5% Pf 2.245 498 17'-9 15.940 2'-0 Pe -0.000 542 17'-9 18.184 E(2'-0) 4'-5%2 Pv BL 1.6100 Q=41.54 6.55 C=120 0.06244.8 7'-8 Pf 0.479 542 17'-9 18.184 Pe 540 17'-9 18.664 7'-8 Pv BL 1.6100 Q=83.22 13.11 C=120 0.225844 4'-6 Pf 1.016 540 17'-9 18.664 Pe 538 17-9 19.680 4'-6 Pv BL 1.6100 Q=105.36 1.6.60 C=120 0.349425 8'-6''A Pf 2.982 538 17'-9 19.680 Pe 537 17'-9 22.662 8'-61A Pv BL L 1.6100 Q=129.18 20.36 C=120 0.50.9.507 16'-10% Pf 14.725 537 17'-9 22.662 12'-0 Pe 0.867 529 15'-9 38.254 2LtE(2'-0), PO(8'-0) 28'-10' Pv CM 4.2600 Q=158.96 3.5.8 C=120 0.006544 10'-0 Pf 0.065 529 15'-9 38.254 Pe 638 15'-9 38.319 10'-0 Pv CM 4.2600 Q=279.51 6.29 C=120 0.01858.9 10'-3 Pf 0.523 638 15'-9 38.319 17'-11 Pe 0.650 703 14'-3 39.493 2fE(8'-11'/2) 28'-l% Pv CM 4.2600 Q=358.39 8.07 C=120 0.029443 98'-6% Pf 4.731 703 14'-3 39.493 62.-1% Pe -1.727 1191 18'-3 42.497 4fE(8'-11%2), PO(26'-4) 160'-8 Pv CM 6.3570 Q=358.39 3.62 C=120 0.00419.2 133'-10 Pf 1.220 1191 18'-3 42.497 157'-2 Pe 14.881 1290 -16-1 58.597 5fE(12'-7), BV(12'-7), CV(40'-2%), 291'-0 Pv GV(3'-9%), PO(37'-8%) FM 8.3290 Q=358.39 2.11 C=120 0.001124 16'-5''A Pf 0.055 1290 -16'-1 58.597 32'-0 Pe 0.000 1405 -16-1 58.652 fE(16'-0), LtE(16'-0) 48'-5% Pv FM 10.4200 Q=358.39 1.35 C=120 0.000378 28'-2% Pf 4.542 1405 -16-1 58.652 83'-0 Pe -0.842 1371 -14'-1% 62.352 4LtE(16'-0), BV(19'-0), BFP(-4.500) 111'-2% Pv UG 10.4000 Q=358.39 1.35 C=140 0.000287 110'-2 Pf 0.064 1371 -14.-1% 62.352 111'-7% Pe 3.407 1 -22'-0 65.822 E(35'-1), 3LtE(25'-6), S 221'-9% Pv cii Route 2 DR 1.0490 Q=20.75 7.70 C=120 0.139334 37'-11 Pf 6.120 102 7'-0% q=20.75 K=5.6 13.733 Spr(-13.733) 6'-0 Pe -4.655 504 17'-9 15.198 3E(2'-0) 43'-11 Pv BL 1.0490 Q=41.68 15.47 C=120 0.506237 1'-10% Pf 3.466 504 17'-9 15.198 5'-0 Pe 540 17'-9 18.664 PO(5'-0) 6-10% Pv Route 3 DR 1.0490 Q=20.84 7.74 C=120 0.140385 37'-0 Pf 6.316 103 8'-0% q=20.84 K=5.6 13.845 Spr(-13.845) 8'-0 Pe -4.221 498 17'-9 . 15.940 4E(2'-0) 45'-0 Pv a Route 4 DR 1.0490 Q=20.93 7.77 C=120 0.141522 32'-7% Pf 5.887 104 7-0% q=20.93 K=5.6 13.966 Spr(-13.966) 9'-0 Pe -4.655 504 17'-9 15.198 2E(2'-0), T(5'-0) 41'-7% Pv ++ Route 5 DR 1.0490 Q=22.14 8.22 C=120 0.157075 30'-9 Pf 7.185 105 10'-6'/+ q=22.14 K=5.6 15.633 Spr(-15.633) 15'-0 Pe -3.138 538 17-9 19.680 5E(2'-0), PO(5'-0) 45'-9 Pv Route 6 DR 1.0490 Q=23.83 8.84 C=120 0.179889 31'-9'% Pf 7.698 106 10'-6% q=23.83 K=5.6 18.101 Spr(-18.101) 11-0 Pe -3.138 537 17'-9 22.662 3E(2'-0), PO(5'-0) 42'-9% Pv Route 7 DR 1.0490 Q=23.99 8.90 C=120 0.182154 13'-6%2 Pf 4.470 107 10'-0'% q=23.99 K=5.6 18.348 Spr(-18.348) 11'-0 Pe -3.571 652 18'-3 19.247 3E(2'-0), T(5'-0) 24'-6'/2 Pv BL 1.0490 Q=48.06 17.84 C=120 0.658953 0'-6 Pf 1.647 652 18'-3 19.247 2'-0 Pe 0.217 651 17'-9 21.111 E(2'-0) 2'-6 Pv M.E.P.CAD, Inc. ?1 AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:26PM Page 5 1 Hydraulic Analysis Job Number: KS0414 Report Description: Ordinary Group I Pipe Type Diameter Flow Velocity Downstream Elevation Discharge K -Factor Upstream HWC Pt Friction Loss Pn Fittings Length Pressure Eq. Length Summary Total Length BL 1.6100 0=48.06 7.57 C=120 0.081807 10'-0'/4 Pf 0.822 651 17'-9 21.111 Pe -0.000 647 17'-9 21.933 10'-0% Pv BL 1.6100 0=72.17 11.37 C=120 0.173509 7-61,4 Pf 1.308 647 17'-9 21.933 Pe 646 17'-9 23.241 7'-6%: Pv B_ L 1.6100 0=96.41 15.19 C=120 0.296520 V-11% Pf 0.281 646 17'-9 23.241 Pe 673 - 17-9 23.522 0'-11 % Pv BL 1.6100 Q=120.55 19.00 C=120 0.448295 19'-1 Pf 13.931 673 17'-9 23.522 12'-0 Pe 0.867 638 15-9 38.319 2LtE(2'-0), PO(8'-0) 31'-1 Pv Q. Route 8 DR 1.0490 0=24.08 8.94 C=120 0.183424 12'-7% Pf 4.332 108 10'-0%4 q=24.08 K=5.6 18.486 Spr(-18.486) 11-0 Pe -3.571 652 18'-3 19.247 3E(2'-0), T(5'-0) 23'-7% Pv Route 9 DR 1.0490 0=24.10 8.95 C=120 0.1837.55 28'-7% Pf 6.549 109 10'-6% q=24.10 K=5.6 18.522 Spr(-18.522) 7'-0 Pe -3.138 647 17'-9 21.933 E(2'-0), PO(5'-0) 35'-7% Pv Route 10 DR 1.0490 0=24.14 _8.96 C=120 _0.184262 32'-10%4 Pf 8.082 110 10'-6%4 q=24.14 K=5.6 18.577 Spr(-18.577) 11-0 Pe -3.138 673 17'-9 23.522 3E(2'-0), PO(5'-0) 43'-101/4 Pv Route 11 DR 1.0490 0=24.25 9.00 C=120 0.185814 30'-1 Pf 7.632 111 10'-6% q=24.25 K=5.6 18.747 Spr(-18.747) 11'-0 Pe -3.138 646 17'-9 23.241 3E(2'-0), PO(5'-0) 41'-1 Pv Route 12 DR 1.0490 0=25.09 9.31 C=120 0.197983 29'-2% Pf 7.564 112 10'-0%4 q=25.09 K=5.6 20.077 Spr(-20.077) 9'-0 Pe -3.354 767 17'-9 24.287 2E(2'-0), T(5'-0) 38'-2'h Pv BL 1.0490 0=50.20 18.64 C=120 0.7.1409.9 2'-93/2 Pf 3.423 767 17'-9 24.287 2'-0 Pe 714 17'-9 27.710 E(2'-0) 4'-9%: Pv BL 1.6100 Q=50.20 7.91 C=120 0.088653 7'-11'A Pf 0.705 714 17'-9 27.710 Pe 712 17'-9 28.415 7-11 % Pv BL 1.6100 0=78.88 12.43 C=120 0.204541 34'-9 Pf 9.560 712 17'-9 28.415 12'-0 Pe 1.517 703 14'-3 39.493 2LtE(2'-0), PO(8'-0) 46-9 Pv Route 13 DR 1.0490 0=25.11 9.32 C=120 0.198189 32'-0% Pf 7.542 113 10'-0% q=25.11 K=5.6 20.100 Spr(-20.100) 6'-0 Pe -3.354 767 17'-9 24.287 3E(2'-0) 38'-0% Pv a Route 14 DR 1.0490 0=28.68 10.65 C=120 0.253501 10'-10%4 Pf 5.542 114 10'-0'/4 q=28.68 K=5.6 26.228 Spr(-26.228) 11'-0 Pe -3.354 712 17'-9 28.415 3E(2'-0), PO(5'-0) 21'-10% Pv c. Route 15 DR 1.0490 0=29.78 11.05 C=120 0.271738 30'-7% Pf 11.307 115 10'-6'/4 q=29.78 K=5.6 28.273 Spr(-28.273) 11-0 Pe -3.571 480 18'-9 36.009 3E(2'-0), PO(5'-0) 41'-7%4 Pv BL 1.6100 Q=29.78 4.69 C=120 0.033735 15'-11 Pf 0.942 480 18'-9 36.009 12'-0 Pe 1.301 472 15'-9 38.251 2LtE(2'-0), PO(8'-0) 27'-11 Pv CM 4.2600 0=29.78 0.67 C=120 0.000295 8'-101/2 Pf 0.003 472 15-9 38.251 Pe 529 15-9 38.254 8'-10'/z Pv Equivalent Pipe Lengths of Valves and Fittings (C=120 only) • C Value Multiplier 4 )4.87 Actual Inside Diameter 4 87 ( Value Of C 100 130 140 150 = Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 k, ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:26PM Page 6 Ail -Hydraulic Analysis Job Number: KS0414 Report Description: Ordinary Group II Pipe Type Downstream Upstream Diameter Elevation Flow Discharge Velocity HWC K -Factor Pt Friction Loss Pn Fittings Length Pressure Eq. Length Summary Total Length Pipe Type Legend Units Legend Fittings Legend AO BL CM DN DR DY FM FR MS OR RN SP ST UG Arm -Over Branch Line Cross Main Drain Drop Dynamic Feed Main Feed Riser Miscellaneous Outrigger Riser Nipple Sprig Stand Pipe Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV AngV b BaIV BFP BV C cplg Cr CV DeIV DPV E EE Eel Ee2 f FDC fE fEE flg FN fT 9 GIoV GV Hose HV Hyd LtE mecT Noz P1 P2 PIV PO PrV PRV red S sCV Spr St T Tr U WirF WMV z Alarm Valve Angle Valve Bushing Ball Valve Backflow Preventer Butterfly Valve Cross Flow Turn 90° Coupling Cross Run Check Valve Deluge Valve Dry Pipe Valve 90° Elbow 45° Elbow 11%° Elbow 22W Elbow Flow Device Fire Department Connection 90° FireLock(TM) Elbow 45° FireLock(TM) Elbow Flange Floating Node FireLock(TM) Tee Gauge Globe Valve Gate Valve Hose Hose Valve Hydrant Long Turn Elbow Mechanical Tee Nozzle Pump In Pump Out Post Indicating Valve Pipe Outlet Pressure Relief Valve Pressure Reducing Valve Reducer/Adapter Supply Swing Check Valve Sprinkler Strainer Tee Flow Turn 900 Tee Run Union Wirsbo Water Meter Valve Cap 0,k,© M.E.P.CAD, Inc. ;?4 AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:26PM Page 7 • 4: Hydraulic Graph ` Job Number: KS041 Report Description: Ordinary Group Pressure, psi c Supply at Node 1 • • Static Pressure 140.000 •608.39 358.39 with hose @ 65.822 streams System demand curve 10900.00 @ 20.000_ IIIIIIII1uuII I I I I I I I I 111 1 1 1 1 1 1 1 1 l I i l I I I 1 1 1 1 1 1 1 1 L 11 1 1 1 1 1 1 t 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 III 11111 I V p 11002200 3300 4400 5500 6600 7700 Water flow, gpm 8800 9900 11000 Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.424 @ 608.39 System Demand 358.39 @ 65.822 System Demand (Including Hose Allowance) 608.39 @ 65.822 Cm, ©M.E.P.CAD, Inc. y AutoSPRINK® VR5 v5.1.32 05/23/2008 3:17:27PM Page 8 OilIS Flow Diagram (Top View) 1 Job Number: KS0414 Report Description: Ordinary Group 11 (AA Cc) M F P r.An Inc. =�3AutoSPRINK® VR5 v5.1.32 05/23/2008 3:19:01 PM Page 2 uS e. r vc G f' Pang .5 `1nY R%A '1124124/2 AI P • 11: n f 'a• a• .. I wi M 6 M v z 1 1 a CAD I r —C -a - I „0on'(50` ; . I I *",° I I~ --1 r= • x0 0 0 0- 0 rt 1 1 I I r k 1 Y O O 4 I WO aN 1P •p 1 3, 4r to 'c O _ l ill? .A si ix F x� 4 la r -n 5 Fl geO x ro 6 E` g i P 3,.7 c.. 3 K1 04 Q ' , a ....., r : Ce -! o �ro o V Cofl N ..cJ O N v) n F3 v. co 3 � u X lSP1 Page: 3 Nola - Fire Systems - Parts List Report 5/20/08 4:35 PM • Fire System Parts List Job # 700611 - Sharky's - Seattle WA Location: Seatle, WA Fire System # 1 Ansul R102 ANSUL-3.0/3.0/1.5 Tag: Hoods Covered: Hood # 1Hood # 3 Gas Valve(s) : Supplied by Ship Otv Item CAS # Vendor # Description Dist CAS Inst Loose 1 1 AT - 1.5 AT - 1.5 TANK(#1A) - 1.5 Gallon SS Tank (for use with 1 0 Automan Release, Actuator, or SS Enclosure (UL)) 2 1 AT - 3.0 AT - 3.0 TANK(#1 B) - 3.0 Gallon SS Tank (for use with 2 0 Automan Release, Actuator, or SS Enclosure (UL)) 1 2 AP - AR AP - AR AUTOMAN RELEASE - Ansul Automan 1 0 Mechanical Release (UL) Tank sold separately 1 3 AP - AE AP - AE ENCLOSURE - Stainless Steel Enclosure Assembly (UL) 1 0 1 4 AP - AA AP - AA ACTUATOR - Ansul Regulated Actuator 1 0 Assembly (UL) 2 5 LIQ -3.0 79372 AGENT - Ansulex Low PH Wet Chemical Agent, 2 0 3 Gallon (UL) 1 6 LIQ -1.5 79694 AGENT - Ansulex Low PH Wet Chemical Agent, 1 0 1.5 Gallon (UL) 1 7 101-20 101-20 CARTRIDGE - Carbon Dioxide 101-20, 3 Gallon 1 0 Cartridge (R-102) 1 9 101-30 101-30 CARTRIDGE - Carbon Dioxide, 101-30, Double 1 0 Tank Cartridge (R-102) 1 10 TLINK TLINK LINK - Test Link Package 1 0 1 11 MICRO -SD MICRO -SD MICROSWITCH -Single Dual Electric Switch 1 0 1 12 HOSEGROMMET 418511 HOSE - Hose/Grommet Package 1 0 1 13 419337 419337 NOZZLE - 2W Nozzle, Dud 0 1 2 14 419336 419336 NOZZLE - 1W Nozzle, Duct/Appliance 0 2 10 16 419335 419335 NOZZLE - 1N Nozzle, Plenum/Appliance 0 10 4 18 419334 419334 NOZZLE - 1/2N Nozzle, Appliance 0 4 2 19 419338 419338 NOZZLE - 3N Nozzle, Appliance 0 2 1 22 419343 419343 NOZZLE - 2120 Nozzle, Appliance 0 1 4 25 418569 418569 NOZZLE ADAPTOR - Swivel Nozzle Adaptor 0 4 18 26 QSA-3/8 QSA-3/8 QUIK SEAL - 3/8" (UL) 0 18 1 27 QPSA-1/2 QPSA-1/2 PULLEY SEAL - 1/2" Hood Seal (UL) 0 1 7 28 S -DET S -DET DETECTOR - Series (Scissor Linkage) 0 7 http://appl.captiveaire.com/Order/FireSystems/PartsListReport.aspx?JobFireSystemld=144531 Page 1 of 2 Received Time May. 28, 9:59AM • a.VV NJ . V2 L.- 1'1 Page: 4 Nola — Fire Systems — Parts List Report 5/20/08 4:35 PM , 2 29 ANS-360FL ANS-360FL FUSIBLE LINK - 360deg F, R-102 and PIRANHA 0 2 5 30 ANS-500FL ANS-500FL FUSIBLE LINK - 500deg F, R-102 and PIRANHA 0 5 1 34 RPS -A RPS -A REMOTE PULL STATION - Aluminum (without 1 0 wire rope) 10 35 PE -LT PE -LT PULLEY ELBOW - Low Temp. Pulley Elbow, 10 0 Set Screw Type 1 36 PE -HT PE -HT PULLEY ELBOW - High Temp Pulley Elbow, 0 1 Compression Type 15 37 SS-SLV SS-SLV STAINLESS STEEL SLEEVE 0 15 7 38 ELB-90 ELB-90 3/8" CHROME PLATED ELBOW - 90 DEG 0 7 6 39 ELB-45 ELB-45 3/8" CHROME PLATED ELBOW -45 DEG 0 6 2 40 TEE TEE 3/8" CHROME PLATED TEE 0 2 3 41 SN -CHAR SN -CHAR SINGLE NOZZLE EXTENDED DROP ASSY 0 3 3 41 SN-CHAR30 DROPEXT-02 Extended Nozzle Drop -30" 0 3 http://appl.captiveaire.com/Order/FireSystems/PartsListReport.aspx?JobFireSystemld=144531 Page 2 of 2 Received Time May, 28. 9:59AM SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-28 REV. 5 4-1-06 Nozzle Application Chart The following chart has been developed to assist in calculating the quantity and type of nozzle required to protect each duct, plenum, or appliance. NOTICE This chart is for general reference only. See complete details for each type of hazard. Hazard Duct or Transition (Single Nozzle) Duct or Transition (Single Nozzle) Duct or Transition (Dual Nozzle) Electrostatic Precipitator (At Base of Duct) Plenum (Horizontal Protection) Plenum (Horizontal Protection) Plenum (Vertical Protection) Fryer (Split or Non -Split Vat) Fryer (Split or Non -Split Vat) Fryer (Split or Non -Split Vat)* Fryer (Non -Split Vat Only) Maximum Hazard Dimensions Length — Unlimited Perimeter — 50 in. (127 cm) Diameter —16 in. (40.6 cm) Length — Unlimited Perimeter —100 in. {254 cm) Diameter — 31 7/8 in. (81 cm) Length — Unlimited Perimeter -150 in. (381 cm) Diameter — 48 in. (122 cm) Individual Cell Length —10 ft. (3.1 m) Length — 6 ft. (1.8 m) Width — 4 ft. (1.2 m) Length — 4 ft. (1.2 m) Width — 4 ft. (1.2 m) Maximum Size (without drip board) 14 in. (36 cm) x 15 in. (38 cm) Low Proximity Maximum Size (without drip board) 14 1/2 in. (37 cm) x 14 in. (36 cm) Medium Proximity Maximum Size (without drip board) 15 in. (38 cm) x 14 in. (36 cm) High Proximity Medium Proximity Maximum Size (without drip board) 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity Low Proximity Maximum Size (without drip board) 18 in. (45.7 cm) x 18 in. (45.7 cm) High Proximity Minimum Nozzle Nozzle Quantity Heights 1 1 1 1 1 1 1 1 1 1 • For multiple nozzle protection of single fryers, see detailed information on Pages 4-12 through 4-14. 13-16 in. (33 — 41 cm) 16 — 27 in. (41 -69 cm) 27 — 47 in. 20 — 27 in. 21 — 34 in. 13-16 in. 25 — 35 in. (64-89 cm) Nozzle Part No. 430912 419337 419337 419334 419335 430192 419336 419336 419342 419342 419339 419340 419338 419342 419338 Nozzle Tip Stamping — Flow No. 1W 2W 2W 1 /2N 1N 1W 1W 1W 290 290 230 245 3N 290 3N Nozzle Application Chart (Continued) Hazard Fryer (Non -Split Vat Only)* Fryer (Split or Non -Split Vat) Fryer (Split or Non -Split Vat) Range Maximum Hazard Dimensions Maximum Size (with drip board) 21 in. (53 cm) x 14 in. (36 cm) (Fry Pot must not exceed 15 in. x 14 in: (38 cm x 36 cm)) High Proximity Medium Proximity Maximum Size (with drip board) 25 3/8 in. (64.4 cm) x 19 1/2 in. (49.5 cm) (Fry pot side must not exceed 191/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity Low Proximity Maximum Size (with drip board) 18 in. (45.7 cm) x 27 3/4 in. (70.5 cm) High Proximity Minimum Nozzle Nozzle Quantity Heights 1 1 1 Maximum Size (with drip board) 14in. (36cm) x 21 in. (53 cm) 1 Low Proximity Maximum Size (with drip board) 141 /2 in. (37 cm) x 26 1/2 in. (67 cm) 1 Medium Proximity Longest Side 1 32 in. (81 cm) Area — 384 sq. in. (2477 sq. cm) Longest Side 28 in. (71 cm) Area — 336 sq. in. (2168 sq. cm) Longest Side (High Proximity) 1 28 in. (71 cm) Area — 672 sq. in. (4335 sq. cm) Longest Side (Medium Proximity) 1 32 in. {81 cm) Area — 768 sq. in. (4955 sq. cm) Longest Side (Low Proximity) 2 36 in. (91 cm) Area —1008 sq. in. (6503 sq. cm) For multiple nozzle protection of single fryers, see detailed information on Pages 4-7 through 4-11. SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-29 4-1-06 REV. s 27 — 47 in. 20 — 27 in: 21 — 34 in. 13-16 in. 25-35 in. (64-89 cm) 13-16 in. (33 — 41 cm) 16-27 in. (41 — 69 cm) 30 — 40 in. (76 -102 cm) 40 — 48 in. (102 —122 cm) (With Backshelf) 40 — 50 in. (102.-127 cm) 30 — 40 in. (76 — 102 cm) 15 — 20 in. (38 — 51 cm) Nozzle Part No. 419339 419340 419338 419342 419338 419342 419342 419335 419333 419340 419341 419342 Nozzle Tip Stamping — Flow No. 230 245 3N 290 3N 290 290 1N 1F 245 260 290 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-30 REV. 3 10-1-02 Nozzle Application Chart (Continued) Hazard Griddle Chain Broiler* (Overhead Protection) Chain Broiler (Horizontal Protection) Gas -Radiant Char -Broiler Electric Char -Broiler Lava -Rock Broiler Natural Charcoal Broiler Lava -Rock or Natural Charcoal Char -Broiler Minimum Maximum Hazard Nozzle Dimensions Quantity Longest Side (High Proximity) 1 48 in. (122 cm) Area – 1440 sq. in. (9290 sq. cm) Longest Side (High Proximity) 1 30 in. (76 cm) Area – 720 sq. in. (4645 sq. cm) Longest Side (High Proximity) 1 36 in. (91 cm) Area –1080 sq. in. (6968 sq. cm) Longest Side 1 (Medium Proximity) 48 in. (122 cm) Area –1440 sq. in. (9290 sq. cm) Longest Side (Low Proximity) 1 48 in. (122 cm) Area –1440 sq. in. (9290 sq. cm) Longest Side – 34 in. (86 cm) 2 Area – 1088 sq. in. (7019 sq. cm) Length – 43 in. (109 cm) 2 Width – 31 in. (79 cm) Longest Side – 36 in. (91 cm) 1 Area – 864 sq. in. (5574 sq. cm) Longest Side – 34 in. (86 cm) 1 Area – 680 sq. in. (4383 sq. cm) Longest Side 24 in. (61 cm) 1 Area – 312 sq. in. (2013 sq. cm) Longest Side – 24 in. (61 cm) 1 Area – 288 sq. in. (1858 sq. cm) Longest Side – 30 in. (76 cm) 1 Area – 720 sq. in. (4645 sq. cm) Nozzle Heights 30 – 50 in. (76 –127 cm) (perimeter located) 30 – 50 in. (76 – 127 cm) (center located) 35 — 40 in. (89 – 102 cm) (perimeter located) 20 – 30 in. (51 – 76 cm) (perimeter located) 10 – 20 in. (25 – 51 cm) (perimeter located) 10 – 26 in. (25 – 66 cm) 1 – 3 in. (3 – 8 cm) 15-40 in. (38 –102 cm) 20 – 50 in. (51 – 127 cm) 18 – 35 in. (46 – 89 cm) 18-40 in. (46 – 102 cm) 14 – 40 in. (36 –102 cm) • Minimum chain broiler exhaust opening — 12 in. x 12 in. (31 cm x 31 cm), and not less than 60% of internal broiler size. Nozzle Part No. 419341 Nozzle Tip Stamping – Flow No. 260 419342 .290 419335/417332 1N/1NSS 419342 290 419343 419336/417333 419335/417332 419335/417332 419335/417332 419335/417332 419335/417332 419338 2120 1 W/1 WSS 1N/1NSS 1N/1NSS 1N/1NSS 1N/1NSS 1N/1NSS 3N Nozzle Application Chart (Continued) Hazard Minimum Maximum Hazard Nozzle Dimensions Quantity Wood Fueled Char -Broiler Longest Side — 30 in. (76 cm) 1 Area — 720 sq. in. (4645 sq. cm) Length — 32.5 in. (82.5 cm) 2 Width — 30 in. (76 cm) Length — 32.5 in. (82.5 cm) 2 Width — 30 in. (76 cm) 14 in. — 30 in. (36 — 76 cm) 1 Diameter 3.75 — 8.0 in. (9.5 — 20 cm) Deep 11 in. — 24 in. (28 — 61 cm) Diameter 3.0 — 6.0 in. (8 — 15.2 cm) Deep Upright Broiler Salamander Broiler Wok SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-31 3-1-O4 Ark). s Nozzle Heights 14 — 40 in. (36 — 102 cm) 35 — 45 in. (89 —114 cm) 30 — 40 in. (76 — 102 cm) Nozzle Part No. 419338 419334 419334 419341 Nozzle Tip Stamping — Flow No. 3N 1 /2N 1 /2N 260 419335/417332 1 N/1 NSS Assembly (3.0 gallon — Part No. 79290 cr 1.5 gallon — Par No. 79291) contains the regulated release mechanism, agem tank, expedient gas hose,for agent tank hookup. and enclosure knockouts to facilitate installing actuation, piping; expellani piping; detection system; and additional equipment. This regu- lated release assembly is used in single, double. and multiple - tank systems and must be mounted to a rigid -surface. The release mechanism can be used to interconnect both the actu- ation, and expellant gas lines as required per system design. The regulator is designed to allow a constant flow of gas into the tank at 100 psi (690 kPa) when the system is actuated: In single. double, and multiple -tank systems, the provided expel- lant gas hose connects the agent tank to the bottom outlet of the regulator. In double and multiple tank system configurations, the back outlet of the regulator is used as an expellant gas feed for one additional tank -enclosure or tank -bracket hookup. The enclosure contains the required knockouts to facilitate this con- nection. If a pressure switch is to be attached to the regulator, additional fittings are required. The tank is mounted within the enclosure. The tank contains an adaptor/tube assembly with a burst disc union: The burst disc helps prevent siphoning of the agent up the pipe due to signifi- cant temperature fluctuations in the area where the tank is located. The tank is mild steel and, under normal -conditions, requires hydrostatic testing every twelve years. - The agent tank is shipped uncharged and must be filled with 1.53 gallons (5.8 L) or 3.06 gallons (11.6 L) of -only ANSULEX Low pH Liquid Fire Suppressant during installation.. The detection and additional equipment required per system design are connected tothe release mechanism. The enclosure contains knockouts to facilitate detection and additional hookups. The system can bI actuated automatically or manually. Auto matic actuation occurs when a fusible link. within the detection system separates in a fire condition. Manual actuation of the system occurs when personnel pull on the remote manual pull station pull ring. EXTINGUISHING AGENT ANSULEX Low pH Liquid Fire Suppressant (1.5 gallon — Part No. 79694 or 3.0 gallon — Part No. 79372) is a potassium -based - solution designed for fast knock -down and suppression of grease -related fires. The agent is shipped in plastic containers which provide one complete tank charge. Agent storage life expectancy is twelve years. The distributor mtist record the batch numbers and date of shipment receipt to be filed with each instal- lation record. Total Tank Row No.* Quantity 1-5 1 6-11 1 ANSUL Type of System Type of Hardware Single 1.5 Gal. Reg. Release Single - 3.0 Gal. Reg. Release ELECTRICAL SWITCHES — LOC - p ft3 The electrical switches are intended for use with electric gas valves, alarms, contactors, lights, contractor- supplied electric power shut-off devices and other electrical devices that are designed to shut off or tum, on when the system is actuated. Switches are available -in kits: One Switch Kit, Part -No. 423878, Two Switch Kit, Part No. 423879; Three Switch Kit, Part No. 423880, and Four Swifdh Kit, Part No. 423881. Each switch has a set of single -pole, double -throw contacts rated at 21 amp, 1 HP, 125, 250, 277 VAC or 2 HP, 250, 277 VAC. Mounting hardware is provided with each kit. N.C. R-102 RESTAURANT FIRE SUPPRESSION SYSTEM (Standard UL 300 Listed) No=Ie Identification Chart Nozzle Nozzle Noz Nozz{e Tvoe Part No Sta moina Roy 1W Nozzle 419336 1W 1 1WSS Nozzle 417333 1W 1N Nozzle 419335 1N 1 1 NSS Nozzle 417332 1N 1/2N Nozzle 419334 1/2N 3N Nozzle 419338 3N 2W Nozzle 419337 2W 2WH Nozzle 78078 2WH 1 1/2 3 2 2 230 Nozzle 419339 230 2 245 -Nozzle 419340 245 2 260 Nozzle 419341 260 2 290 Nozzle 419342 290 2 2120 Nozzle 419343 2120 2 1F Nozzle 419333 1F 1 Itoo 147z4.E -3ogt2 Ileo Nitrogen Cartridge Required LT -20-R (7032) LT -30-R (5373) tt;%K71)1'1-1-0'. ` T 5 S -p 5 LL P;t fZ 5j r5 OT -c Carbon Dioxide Cartridge Required 101-10 (15850) 101-20 (17492) SECTION IX - APPENDIX UL EX. 3470 ULC CEx747 Page 9-1 7-1-98 REV. 3 SYSTEM SELECTION GUIDE NOTE: System options do not cover all conceivable variations. They are listed here as a general guideline to show the most common type arrangement for multiple systems, Based on certain system designs utilizirig manifolding, non-manifolding, 3 -tank systems, ► etc., other tank/cartridge combinations can be designed. The combinations below are based on 11 flow, 3.0 gallon tanks and 5 flow, 1.5 gallon tanks. More competitive designs may be available by utilizing 12 flow and 6 flow systems when appropriate. Total Tank Type of Nitrogen Flow No.* Quantity System Type of Hardware Carbon Dioxide Cartridge Required Cartridge Required 1-5 1 Single 1.5 Gal. Reg. Release LT -20-R(7032) ) 101-10 (15850) 6-11 1 Single 3.0 Gal. Reg. Release LT -30-R (5373) 101-20 (17492) 12-16 17-22 23-27 28-33 28-33 (Optional) 34-38 39-44 45-49 50-55 56-60 61-66 2 1.5 Gal. Reg. Release 3.0 Gal: Additional Tank Double Double Multiple Multiple Multiple Multiple 3 3 3 4 4 5 5 6 6 3.0 Gal. Reg. Release 3.0 Gal. Additional Tank 1.5 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Release (2) 3.0 Gal. Additional Tanks 1.5 Gal. Reg. Release • 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 3.0 Gal. Reg. Release 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 1.5 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 3.0 Gal. Reg. Release 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Multiple 1.5 Gal. Reg. Release 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator' 3.0 Gal. Additional Tank Multiple 3.0 Gal. Reg. Release 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 3.0 Gal. Additional Tank Double (73022) Double (73022) LT -20-R (7032) LT -A-101.30 (29187) LT -30-R (5373) LT -A-101-30 (29187) Double (73022) 101-30 (15851) 101-30 (15851)" 101-10 (15850) 101-30 (15851) 101-20 (17492) 101-30 (15851)" N/A Double (73022) 101-30 (15851) LT -A-101-30 (29187) 101-30(15851)"' Double (73022) LT -A-101-30 (29187) LT -20-R (7032) LT -A-101-30 (29187) LT -A-101-30 (29187) LT -30-R (5373) LT -A-101-30 (29187) LT -A-101-30 (29187) Double (73022) LT -A-101-30 (29187) LT -A-101-30 (29187) Double (73022) LT -A-101-30 (29187) LT -A-101-30 (29187) - Based on 5 flow numbers for a 1.5 gal. system and 11 flow numbers for a 3.0 gal. system. See Pages 4-39 - 4-42 for exceptions. 9 tanks are manifolded, only a "double tank" nitrogen cartridge (Part No. 73022) can be used. If tanks are manifolded, either an LT -A-101-30 nitrogen cartridge (Pan No. 29187) or a double tank cartridge (Part No. 73022) can be used. 101-30 (15851)" 101-30 (15851y- 101-10 (15850` 101-30 (15851)- 101-30(15851)*** 101-20 (17492) 101-30 (15851)*** 101-30 (15851)*'" 101-30 (15851) 101-30 (15851)- 101-30 (15851)- 101-30 (15851)- 101-30 (15851)*** 101-30 (15851)*** a ACCEPTED ❑ Without Comments As Noted In Red Per The Attached Letter i nese plans have been reviewed by The Tukwila Fire ; : vention Bureau for conformance with current city ,taildards. Acceptance is sub1ect to errors and ,.missions which do not authorize violations of adopted fanaaras and ordinances. The responsibility for the dequacy of design rests totally with the designer. =additions, delet;ons or revisions to these drawings atter this date will void this acceptance and wll require a I resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire, Prevention Bureau. Date: k / i7 0 By: -�07oV fUKWILA FIRE DE.PAtt f ivIG. . Please call: 575.4407, and give this job No.O 3 H ?- Ind exact address for shut. or restoration approval NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. 0 LL Zr J eN �O CCV� CO N O M O Lt. L.L. W W Q a u 66 66 a4 z J J • X O esi CO ▪ W M d tE n o !Aq n cc y N '5 LLi� ▪ C-_ a .9.).., e • E sl E C R. a) Q. 0 03 • Y O • E E• s C U p6 y E O)) c O a) a - ilt Y Q. m o « ° :1-_- « c a z •• 0 0 W _ N O — X7:4❑� 0 • o M Imo, • a) > teii •erIII o ° 03 ��,CD O C x I N of N rn w Q- T2 0 3 _ .0 :5- _v , 8 a 0 ti• b-' a 7 r� c m 0: 2 N00 01 ..... J 0) a6) C u. V) Y 43 0 2 a) 0 tel d C Q a) a) as g = E E ▪ a O t 03.0 Q C 0 0 O O m Q 0) 0 d C ■ s. ui F- 0 z a 03 a) s 0 0 U 03 U C 03 U E 03 a) a C V Nritnherof Pages (Including ('nvet) 01/21/2014 13:42 4254818695 FAX TRANSMITTAL CROWN FIRE PAGE 01/01 Fax No. CROWN FIRE PROTECTION, INC. Lam= 1.21.14 HIM Fine Prevention Bureau EOM Tukwila Fire Department / Al Dextro Permit 206.575.4439 a Wbri.A FIRE DEPARTMENT Ause call 206-575-4407 crtl Eiy2 this Fire Permit No. /`l -S -Oil and exit address for shut- down n or reaoration approval. 0 Urgent L1 For Review 0 Please Comment 0 Please Reply Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comment Please provide a demo permit to remove (4) sprinkler heads that are in the way of the flaming at the Ghipolte project at 2600 Southcenter Mall. The building permit # is D13-319.. Please let us know if you have any questions. Thanks— etaliCIATIPOTeNIIINALCY f1: PROTECTt0N SMtINK(,E1t SYSTEMS a i John J. Abel i ! 9760 -0591 -CG Laval Crown Fine Protection, Inc. C • NF 6.iMFwr�r��Nw+'.rima P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX 425.481.8695 a CHIPCYTI, CAN G 11,1d ......."' u�wwaa�aaw.an�x.,wmxat'';$ _.,.,, `4w.�,.....� _.�.�?a 4a:,,.,...., ...,..aA?t�'»:�»...� ,�r;a�Sk SHEET \U v1.3E� SHEET TITLE FIRE AI4IAI,M SADDITION K .ILA, ,°, 1.SHIN ;TSN FA -01 SYSTEM \FO ATI O \ FA -02 TYPICAL WI I\G A \D IVOU \TI \ G DETAILS FA -03 SYSTEM CALC U LATI O \ S A D SI\GLE LI\E DIAGAV FA -04 FRE ALAN SYSTEM FLA\ A :7741,774to d EE�� Without Comments Ci As Noted in Red Q. Per,The Attached Letter These plans have been reviewed by The Tukwila fire Prevention Bureau for conformance with current Cid ;tandards. Acceptance is subject to errors and ;:missions which do not authorize violations of adopted Landards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The, Tukwila Fire Prevention Bur u. Date: I LS I L By: QED SI -INDEX 4 completed, signed, Tukwila Fire Department Pre-test Certificate must be -presented to the Inspector prior to commencement of Acceptance Testing of any Fire Mann and Detection Systerls. Failure of test witl:rett in a Re -inspection Fee F termination of the t Tit.A FIRE DEPARTMETT call 206-575-4407 ard 45173 this Fire Permit NO. exact address for shut down CT • ULE ANI 'I IT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF..CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKED D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC - TWO ' •#16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKED S' STROBE CIRCUIT - RETURN TWISTED PAIR 1'A// SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEEDTWISTED PAIR #14 FPL/FPLR RED (JACKET) V' - SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.0. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSER\/ED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE 'NITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDAVT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 1 1 2 1 4 EX SYMBOL DESCRIPTION BPS TSM REMOTE BOOSTER EX POWER SUPPLY DUCT DETECTOR DUCT DETECTOR TEST SWITCH MODEL PAD -3 MANUFACTURER BACKBOX SIEMENS AD2-P W/ SIEMENS HFP-11 DET. TSM -1 SIEMENS PAD-3-ENCL DUCT HOUSING 1 -GANG BOX MOUNTING HEIGHT 66" A.F.F. TO TOP VERIFY IN FIELD VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD HT -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP BOX VERIFY IN FIELD S FIRE ALARM SPREAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2 EXTN EX FIRE ALARM JUNCTION BOX (EXISTING) F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND 121601 121701 12120) 22061 [ FcD JOHNNY 1FC141 F'C1J THAI CO 0 RETAIL IFC13J RETAIL TI ERVCE 1 FC61 / CAFE PHO ROOF ROOF T 'RACE CH I POTLE #2600 / STORE #2270 PAID JAM 13 2013 TUKWILA ARE WIRE DESIGNATION GENERAL NOTES SITE PLAN g'v RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE v 0 0 J J t zwc 0 0 cr' � F- 0 <C (' o J1 - J W Z W • O) W� O ,� a. LL 5))1.--D T (I 8 �-+ N ‘CALE: NOT 0 0 z DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 10/ 14 BACKROUND PLAN PROVIDED BY: Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER: 7692-1J SHEET FA -01} ij 120VAC-6CHZ - DEDICATED EMERGENCY THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC DEFRONSlUUiVDINO TD NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE - FROM XLS CONTROL PANEL l OR PREVIOUS ADDRESSABLE DEVICE J 0 O O HTRI-R ° 011 U 0 PAD -3 00 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 NOTE: SSEEEE ADDITIONAL DOCUMaENTATIONN.s C -CABLE C -CABLE (-) (+) (-) (+) SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) O❑ NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) O WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 :PUFPLR RED (JACKET) *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC , FOR ADDITIONAL SPECIFICATIONS SEE FRODUCT DOCUMENTATION. O 0 r GROUND 1© ©O I - 'I HTRI-R I B _ O o (+)> TO NEXT DEVICE OR ❑o _ 1.xrs: 1 m 0 1 1 0 DESCRIPTION ?� /. /."R' o 0 o ��1 T O 'E‘ (il B €la}. B � NAI I x - r" A BC DCC CII rA 8 « 1:11:1:111:1:1= In' rl:I 11:1:1= k-0,,, —mil I `'al I:I:I:I:I 11*' . C A 0 0 - _ o❑I (-) STOP IF LAST DEVICE DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL STROBE SPEAKER ❑o ❑OBJ UIHCUI1 �Qo SPARE SPARE (-) POWER SUPPLY & RELAY MODULE WIRING DETAIL FROM PRECEDING SPEAKER < OR FIRE ALARM CONTROL PANEL < (+) (+) (-) STROBE STROBE 1 ❑ o 11 O 1 m 0 li - 1 — DESCRIPTION SHOP DRAWINGS /. /."R' - 1 0 DATE 0 O O 'E‘ (il B B � NAI I - 8 « __ In' rl:I 11:1:1= I `'al I:I:I:I:I 11*' a A 0 0 - _ :;B,11( - 1 ❑OBJ UIHCUI1 �Qo SPARE SPARE (-) POWER SUPPLY & RELAY MODULE WIRING DETAIL FROM PRECEDING SPEAKER < OR FIRE ALARM CONTROL PANEL < (+) (+) (-) STROBE STROBE 1 ❑ o 11 O 1 m 0 0 1 DESCRIPTION SHOP DRAWINGS 0 DATE 0 ( 'o B B � NAI I - TIBC D[(Gx 11 « __ In' rl:I 11:1:1= NO ❑=1), VInVVl1 \Qo❑ ❑oD (-) (-) SPEAKER CIRCUIT (+) (+) STROBE CIRCUIT SPEAKERISTROBE Qo❑ I I () 0 0 I:I I:I:1'1 I:1:1 (+) (+) SPEAKER CIRCUIT SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS (+) STROBE CIRCUIT (-) r (+) ,\ (+) (-) SPEAKER CIRCUIT 5 TO NEXT APPLIANCE S OR 24K (EOLR) TO NEXT SPEAKER OR END OR LINE RESISTOR 24K (EOLR) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER 11N TEMPERA RE: +32' F (0' C TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR --> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) >- DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL HARD LID CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE > TO NEXT ADDRESSABLE DEVICE 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSION CEILING MOUNTED SPEAKER/STROBE 000 o ° eo 000 0 oo0 SPEAKER STROBE MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX ",' V..I �42,4i61i2 t,Iw 42.1r2M�',Iwi�O'Iw 4,21 t,IwieS4 s',IwPAK4,24.r wi ��Iwi+',Iwi�.421f4J1'4;wi• eO� JUNCTION BOX MOUNTED AGAINS CEILING SUPPORT SMOKE/HEAT DETECTOR TO NEXT DEVICE CADDY BAR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved rr) Co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-654.5 RELEASE/REVISIONS REV. BY: m 0 DESCRIPTION SHOP DRAWINGS DATE 0 0 I « J J CC 0 z U_ w W J 0 0 U N zw000 • T I— O CD z < JO Q W Z CC W CCw• � LU! w= CC LL 0 (ID J O cc SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:01 /10/14 BACKROUND PLAN PROVIDED BY: \ OB NUMBER: 7692-1} SHEET FA -02 ' ' N' , ,, I, „ .,„ , GRILL„,„ f FACPADONS Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS DATE Current Load: Standby: Alarm: Standby: MAlarm:‘ <<<<< ..:., . Device Type Qty Amps Total Amps Total Amps HFP-11 Amps 0.0022 0.0022 0.0023 0,000 . AD2-P 1 0.0635 0.0635 0.064 0.064 Main System Board HTR -RID 3 0.009600 0.0096 0.021 0.063 SET -MC -C ©15CD . ,' ' '',: :',15 - , 0.0875 1.313 SET -MC -C ©30CD 12 0.131 1.572 SET -MC -C @75CD, - , . 0.0731 Amps 0.127 Amps ,,,. e,. ! ' "„ ..;' „ .,„ , GRILL„,„ f EXISTING SIEMENS PAD -3 SignaI Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS DATE Z 0 0 J,.-rrer4,) yo4 " Standby: MAlarm:‘ <<<<< ..:., . ' • Device Type Qty Amps Total Amps Total , . . . Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -C ©15CD . ,' ' '',: :',15 - , 0.0875 1.313 SET -MC -C ©30CD 12 0.131 1.572 SET -MC -C @75CD, - , . . : 22g o. 1.332 SET -MC -C @95CD 0.292 . SET-MC-C,©iioco, , " ' .03.259 ‘• 1ZR-MC ©15CD 14 0.064 0.896 ZR-MC'©30PD ' , . '7 0.098 0.686 ZR -MC @75CD 0.175 . , . 0.03 . „ Amps ', 5.8285 Amps Standby Curnt Load: . .' :OA* Amps , For 24 Hours = 0.720 Amp -hours . Alarm Current Load: :: ' i' - :,• 5.8285 Amps ' „ Pot,5,,Mintite. '...,' 0.490 Amp -hours . „ . „ 25% Derating*. 1.512 Amp -hours . . ' . Total System Current Load: 1.512 Amp -hours . . ,. . Battery,Pair :be fUsed:'' ;x- I2VDC 4,.ke; ,.., .0.4 Notification Appliance Circuit Detail PROJECT: CHIPOTLE MEXICAN GRILL 1 1 . , .. ...._...._ .... .1 Panel: EXISTING PAD -3 POWER SUPPLY11/1/ire Resistance 2.58 : i Date: January 10, 2014 5 e"'el"fer,i?""if CURRENT TOTAL=1437.00 2 SET -MC -C ©15CD 1 87.51 175! 2 SET -MC -C ©36CD 131 ' 262 'SET -MC -C ©75CD 222[ , 0 ,SET -MC -C ©95CD 292 0 ZR -MC ©110CD 2591 0 i 7R -MC ©15CD ' 64 0 ZR -MC ©30CD 714 -MC 475CD DEV10ES=14 981 175 TOTAL mA= 1Total Wire Resistance ( R ) Total Device Load, Amps (1) !Voltage Drop ( E ) EOL Voltage 0 437 14 275 23.38 4371 .(WL* 2 )*(R/ft) 1 1.421 (Total Cct Load) 044 24 Notification Appliance Circuit Detail PROJECT: I CHIPOTLE MEXICAN GRILL Panel:IXLS-V 1Wire Resistance 2.58 Date: January 10, 2014 CURRENT TOTAL= 108.66 70.7V 1/8 70.7V 1/4 170.7V 1/2 0 70.7V DEVICES=142 1.81 41.4 3.54 67.26 01 0 TOTAL m A= !Total Wire Resistance ( R ) Total Device Load, Am 0) 1Voltage Drop ( E ) EOL VOltage • . 0 i08.661 „ „ 1 14 1,217 19.717645621 108.661 (WL*2 )*(R/ft) 6.28 :(Total Cct Load) 0 11 1(E= I * R) 1 0.681 (20.4:.•"! E), • 19.72 FAX (206) 628-4990 TEL. (206) 622-654-5 SYSTEM CALCULATIONS v,v. TO NEAREST EXISTING VOICE CIRCUIT (V2C) TO NEAREST EXISTING POWER SUPPLY (PS2C) TO NEAREST EXISTING DATA LOOP (DATA LOOP 2) ( D EX EOL S1 LOCATED ALONG THE CORRIDOR D S1-1 15cd v1-1 HT -R S1-2 1 5cd V1-2 D,I 1 HT -R 21 1 TSM S1-3 30cd V1-3 S,S' V,V' S1-4 30cd V1-4 1-117----1: FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. MONITOR MODULE TO MONITOR KITCHEN HOOD. RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE Z 0 0 <<<<< c\I cc c0„. 40 re W 1/4.:J 0 cc c-17 Z Ic":57) ;) 0 < <0 >t< Z CC I Luatt) 2 Z W CC w < Ouj 15 cC CL u_ cy)F- 8 c9 CC 00 w z w 0 z (/) 0 zz0 -J C.) Cin (i) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:01/10/14 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved .JOB NUMBER: 7692-1i I. SHEET FA -03 S1-4 30cd V1-4 i It i S1-1 15cd V1-1 111 L II 1-...�� ..-1 LJLJLJ S,SV,V1 s,s',v,V /: S1-3 30cd V1-3 .-m fj S S1-2 15cd V1-2 ri EX S,s',V,V' EOL S1 HT -R I �TSM I —c� _11.. Ell_Ell.13:11- .1 I_ _ J,_ FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. MONITOR MODULE TO MONITOR KITCHEN HOOD. Pro•rietar and Confidential, Co• ri•ht 2012 b Guardian Securit S stems, Inc. All Ri•hts Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 0og DESCRIPTION SHOP DRAWINGS DATE 01/10/14 2<a<aa 0 N woe co C.030cC (73 1-OOcs� < (4.5 U<�I- �z Wcc_ 2�1- J on �-Q = cc a. LLOI- o - o U N Z 4-CALE: 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 10/ 14 BACKROUND PLAN PROVIDED BY: �OB NUMBER: 7692-1} r- SHEET FA -04 ( SHARKY FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \ UV3ER SHEET TITLE FA -01 SYSTEM I \ FORMATION FA -02 TYPICAL DETAILS - WIRI\G A\3 N OU\TI\ G FA -03 FRE ALARM SYSTE VI FLOOR PLA\ FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLA\ WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BONG RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO 'CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C.;- AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED: BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES' IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR. TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ';ON FIRE ALARM: RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION, BOXES AND FRCP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL. BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME ` CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 30.5 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M -(4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD B Q LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN HELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING D DUCT SMOKE DETECTOR AD2-P W/ SIEMENS DUCT HOUSING VERIFY TSM MODULE IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXT. FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM SET -HMO -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. c FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING L FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXT. Q FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1 /2" EXT. TO BOTTOM B AWP FIRE ALARM STROBE (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. .B: F.B.O. VERIFY S IN FIEL JUNCTI❑N BOX F.B.O. 1~.B.❑, � I/ 'thout Comments • VERIFY ; IN FIELli, A.F.F. HDU V L f IIV1JflLL FL❑❑R IV/ H I •i/ H f r. As Not ' f i i Red ivi H MI °3 •- ' F- •-• -j- FURNISHED BY OTHERS N/A /A N/A N/A 'nese plans have been reviewed by The Tukwila Fire N/A NOT APPLICABLE N/A ,SPandards. Acceptancel�Aubiect to errors and N/A omissions which do not authorize violations of adopted LION. UNLESS OTHERWISE NOTED N/A }Mequacy of design rest4/tAtaiiy with the designNl/A Additions, deletions or revisions to these drawings atter WP WEATHERPROOF DEVICE N/A Hsubmittal of revised ditkilngs for subsequent 4.0ADval. ' ' '. A comp Fire [ RED AS BUILT ADD ❑R CHANGE N/A • - • •'- - . - __ • . - . , w-tthe Tukwila Fire, Prevehlti i Bureau. N/A i d ,,- AN 1 -- I IG to th Iilsn- GREEN AS BUILT RRMfVF N/A a e. ►if7M AIWO ___ Testir /A N/A - N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A 1 UKWILA FIRE DEPART:..Liit Please call: 575-4407 and give this job No.©? and exact address for shut' down or restoration approvall, 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS z DESCRIPTION SHOP DRAWINGS iu a 0 co 0 u-) 0 z C C VJ CC cc Q g Q NOTICE feted, signed, Tukwila )epartment Pre-test ate must be preserted e Inspector prior to Icement of AcceptE nce ig of any Fire Alarm Detection Systems. Failure of test will result in a Re -inspection Fee an i tcrlination of the testing. AI JUN 1120 Tukwila Fire ItD13'0 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved J SCALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: .OB NUMBER: SHEET �A THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE FROM XLS CONTROL PANEL OR r PREVI❑US ADDRESSABLE DEVIL STOP IF LAST DEVICE DUCT DETECTOR L❑CATION O END OF LINE DEVICE(3.GK 1/4W) SUPERVISED SWITCH O NI" m GROUND © © HTRI-R STATUS LED co (0 B 0 O N.O. COM N.0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE_ DEVICE TO NEXT ADDRESSABLE DEVICE L - NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX, CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX, LINE SIZE - MIN, LINE SIZE - MUSIC OUTLET SAMPLING TUBE INLET SAMPLING\ TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE f(+) STOP IF LAST DEVICE l(-) FROM XLS CONTROL PANEL OR f(+) PREVIOUS ADDRESSABLE DEVICE () RELAY CONTACTS (4.OA @ 125VAC) (4.0A @ 30VDC) 27 VDC 3,5 rmA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0,02uF 0,04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. 0 1001 TB1 5 0 0 0 0 123456 TB2 CP 654321 0 0 O N END OF LINE DEVICE 5 (3.6K 1/4W) O SUPERVISED____' SWITCH GROUND r) © © HTRI-D OSTATUS LED 00 0 O NOT USED CD 0 O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL Lia SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC _n 0 0 0 ED YT T U 0 0 PAD -3 0 CO O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 24K n TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END OF LINE DEVICE 3.6K 1/4W) \SUPERVISED 1 SWITCH ?NAC -4 NAC -3 NAC -2 NAC -1 ( FRONT NEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0 0 0 [FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS IW EOL INPU' P9 TSM -1 0 0 if 0 CC CO TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL FROM REMOTE POWER SUPPLY C'S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) SCALE NUE EARTH GROUND --)(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE + C (STR❑BE) SPEAKER (+) ( ) (+) ( ) STROBE () STR❑BE) (SPEAKER ) 0 SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80" A.F.F. 4S DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0PER�11N TEMPERATU E: +32' F (0' C) TO 100'F (38' C) HUMIDITY: O-93333332 RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE tDATA IN (-) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR ---- DB -11 STANDARD SMOKE DETECTOR BASE TO NEXT DEVICE< REAR VIEW >( ) DATA OUT I > (+) DATA OUT Jr HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING HARD LID --- ----- SPEAKER SUPPORT T ` - BRIDGE z 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTION BOX MOUNTED ON CEILING, FLEX / JUNCTI❑N BOX ----- MOUNTED AGAINST CEILING SUPPORT 0 0 FTS 1 TO NEXT DEVICE 0 0 ------ CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE=NONE SUSPENDED ILLUMINATED CEILING DO NOT INSTA_L ADDRESSABLE NITlATING DEVICES .,NAIL PREPROGAMMED WITH D=VICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All . Rights Reserved ca z 0,4 z 00 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS co W O I— `n Ln 1 _I CO Q CO 1- 2 (a 2(a (�WO - z E' W z cr cc = (1) Q =Qo3: (!) Ley c1 0 CO = tV I__ SCALE: 1 /8"=1 Z 0 0 z t� z 0 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: \OB NUMBER: SHEET FA -02 1 _\ --------------------------- ----- ---- -- f \\ 2C-3-2 110cd -r. 2S -= - 1 1 a 1 ' I 1 I ts ,' II 2C 1 V2 i. 2C-3-1 110cd NORTH I • it �\ -;8 i1 25,2V 1 jJel /71 HARKY'S m--2S,2V mrr 2S 2V E D,2S,2V 2C -2- I ///::// V2C- 1 QD- 2 U 2V FLAG NOT 2C-1-1 15cd V2C-5 ,2V EOL—S1 20.34V 2C-1-3 15cd V2C-7 s,v S 2 S 2 1� 15cd V2C-12 S,2V SHARKY'S WESTFIELD SOUTHCENTER MALL SCALE 11811=1' 2-53 PS2C o -D 2C -3 1 d V2C-14 FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM, FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. DO NOT INSALL ADDRESSABLE IN DEVICES U\TIL DREPROGRAMV DEVICES ADDS T ATING ED W ;ss. H Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ro co ® ON it Z O Z zCII3 w_ LIU < Iii a LLI6 Itio '-" C4 w•I N Ll_I N Ct Q IS (/) I- O - N NW Ca - W - I- FAX (206) 628-4990 RELEASE/REVISIONS m W DESCRIPTION SHOP DRAWINGS LU co 0 O z C C J uJ Q�(/) T O) w �o UZ ite r2c ce4q EC !!= Q u) vJ W NJ o op CV 11.1 SCALE: 1 /8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: .OB NUMBER: C SHEET FA -03 / / L41.1 SYSTEM CALCULATIONS ---- ---_- ---- 0 0 1 _ }3'> 3" - - ," 1 l l 1 N ! 1 NORTH ------------ 0 0 1 \k\ , 0 1 ‘k: x +-"mo-21\-1 111 , \-1-‘ l� / 11 PTV, SHARKY'S WESTFIELD SOUTHCENTER MALL \ , j - �> �i SCALE 1/32'=1' 2S,2V b, 30 FA -BOX FACP BATTERY SIZING CALCULATON SHARKY'S SHARKY'S Detail FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations PROJECT: Panel: SHARKY'S Wire Resistance 1.62 Date: June 10, 2008 CURRENT TOTAL 98 CIRCUIT: Current Load: Standby: Alarm: Current Load: Standby: Alarm: Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 0 SET -MC @15CD 64 0 Device Type 0.62 Qty Amps Total___ Amps Total Device Type Qty Amps Total Amps Total 0 HFP-11 0.0022 0.0022 0.0023 1 0.10 0 SET -MC @110CD 233 0 AD2-P 0 0.0635 0.0635 0.064 Main System Board 1 0.03 ( E) 0.03 0.030 0.030 445 HTR -R 0.009600 0.0096_ 0.021 (E= I * R) SET -MC @15CD SET -HMC @135CD 318 0 0.064 HTRI-D 20.34 0 0.001600 445 0.0035 SET -MC @30CD 1 (20.4 - E) 0 0.098 0.098 0 ICP -B6 0.005 0 SET -MC @75CD 98 0 0.175 0 SET-MC-CW@110CD 233 0 SET -MC @110CD DEVICES= 1 0.233 98 12 191 20.339353681 981 Notification Appliance Circuit Detail SET HMC-C@115CD PROJECT: WESTFIELD SOUTHCENTER MALL 0.318 Panel: SHARKY'S Wire Resistance 2.58 Date: SET HMC-C@135CD CURRENT TOTAL 1.8 CIRCUIT: SPEAKER CIRCUIT 0.318 QTY 0.0731 Amps Alarm Total Amps SET HMC-C@185CD Voltage at EOL Circuit Total 1 70.7V 1/8 1.8 0.445 Total Wire Resistance (R) 0.99 0 0 0 ZR -MC @15CD (WL*2)*(R/ft) 0 0 0 0.064 Standby Current Load: 0 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 0 0 0 0.098 Voltage Drop �J ( E) 0.00 0 0 0 HCP 0 0 0 0.0015 EOL Voltage 20.40 Alarm Current Load: 0 Amps For 5 Minutes= Amp -hours 1 (20.4 - E) 0 0 0 0.03 Amps 0.128 Amps 0 0 DEVICES= 1 TOTAL mA= 1.8 14 191 20.39822599 1.8 25% Derating= 2.193 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.128 Amps For 5 Minutes= 0.011 Amp -hours Total System Current Load: 2.193 Amp -hours 25% Derating= 0.913 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 0.913 Amp -hours Battery Pair to be Used: 12VDC 1 Amp -hours 7AH BATTERY SIZING CALCULATON 1743 IST TEL. (206) 622-6545 RELEASE/REVISIONS z a DESCRIPTION cn z a 0 a. 0 w co 0 1n LO 0 z 0 LU O LU C) e co CC J co <T- caJ 2 wit z �C WRQ CC () z� LLI UZ CC CC II LU = < co> (!) 0 C) J U W VJ \ SCALE: 1 /8"=1 DRAWN BY: I.ANDERSON DESIGNED ' BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: \ 0B NUMBER: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -04,, WESTFIELD SOUTHCENTER Notification Appliance Circuit MALL Detail PROJECT: Panel: SHARKY'S Wire Resistance 1.62 Date: June 10, 2008 CURRENT TOTAL 98 CIRCUIT: S1 QTY Device Type Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 0 SET -MC @15CD 64 0 Total Wire Resistance (R) 0.62 1 SET -MC @30CD 98 98 0 SET -MC @75CD 175 0 Tota Dev Device Load Amps 1 0.10 0 SET -MC @110CD 233 0 (Total Cct Load) 0 SET-HMC-C@115CD 318 0 Voltage Drop ( E) 0.06 0 SET-HMC-C@177CD 445 0 (E= I * R) 0 SET -HMC @135CD 318 0 EOL Voltage 20.34 0 SET -HMC @185CD 445 0 (20.4 - E) 0 Z-MC@15CD 64 0 0 Z-MC@30CD 98 0 0 SET-MC-CW@110CD 233 0 DEVICES= 1 TOTAL mA= 98 12 191 20.339353681 981 Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: SHARKY'S Wire Resistance 2.58 Date: June 10, 2008 CURRENT TOTAL 1.8 CIRCUIT: SPEAKER CIRCUIT QTY Device Type Alarm Current Alarm Total Wre Size Wire Length Voltage at EOL Circuit Total 1 70.7V 1/8 1.8 1.8 Total Wire Resistance (R) 0.99 0 0 0 (WL*2)*(R/ft) 0 0 0 Total Device Load, Amps (I) 0.00 0 0 0 (Total Cct Load) ll 0 0 0 Voltage Drop �J ( E) 0.00 0 0 0 (E=I*R) 0 0 0 EOL Voltage 20.40 0 0 0 1 (20.4 - E) 0 0 0 0 0 0 DEVICES= 1 TOTAL mA= 1.8 14 191 20.39822599 1.8 1743 IST TEL. (206) 622-6545 RELEASE/REVISIONS z a DESCRIPTION cn z a 0 a. 0 w co 0 1n LO 0 z 0 LU O LU C) e co CC J co <T- caJ 2 wit z �C WRQ CC () z� LLI UZ CC CC II LU = < co> (!) 0 C) J U W VJ \ SCALE: 1 /8"=1 DRAWN BY: I.ANDERSON DESIGNED ' BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: \ 0B NUMBER: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -04,, 1; APPROXIMATELY 850 SF oil 1.41 toss r l :.:\ OM Sal SE"VING 103 Li .. .... t POs 1 �t 101 -� (sr'ti ��� °KING!�.. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS f=ire City j' i'? ::()opted •''n -atter 1 1. TCHEN LIT .tz ,Q FIRE PROTECTION PLAN 1/4" = 11-0" 1j E ........... .__ .._..I+ .l ii 1 IE:- -. ,L ° ...._._....._......... .... .__ ' iit Emu ma raw En as Assn li FO-514,DCi COOLER- 1 1 1 1 1 Design per NFPA 13, Ordinary Hazard Group 2, Retail — 130 Sq, Feet Max All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 14 — Reliable Model G5-56 165° Standard Response Pendents 1/2 x 1/2 (concealed white) A 1 — Globe Model GL5635 200° Quick Response Dry Pendents 1/2 x 1/2 - i• i uI arra inspection byj 51( WASHINGTON STATE CERTIFICATE OF COMPETENCY . FIRE PROTECTION SPRINKLER SYSTEMS John J. Abel 9 60 -0591 -CG Level 3 wn Fi Protection, Inc. k- CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113. MILL CREEK, • WASHINGTON 98082-0113 PH. (425) 481-7669 12/3111.4 4 �ti.4 STORE # 2270 Southcenter Mall 2600 Southcenter Mali, FC -2 Tukwila, WA 98188 JA TUK` .PAID 93 .%nett ILA FIRE 20 ? 5% DATE: 1v wry TJ CHIPOTLE.n 1 ,. / CHIPOTLE �_ A IIIA IP' ..�.. „,.4,_1166 ill 17:= \ rYw'I . ii i, a.: I ' "' pI 2600 SOUTHCENTER MALL ' ICSTM 1 I esusiw..a !Manr+...ti CIITY JIMAP ® ®O KEY PLAN SG& NDTTo9CV.E - moo stat NorfO5C.0 . CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113. MILL CREEK, • WASHINGTON 98082-0113 PH. (425) 481-7669 12/3111.4 4 �ti.4 STORE # 2270 Southcenter Mall 2600 Southcenter Mali, FC -2 Tukwila, WA 98188 JA TUK` .PAID 93 .%nett ILA FIRE 20 ? 5% DATE: 1v VICINITY MAP (Suite#2600 FC -02) SCALE: NTS General Notes 1. Western States Fire Protection to add new pendent heads new and branchlines in new tenant space. Sprinklers in the new store shall be spaced lin accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of alt sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only jn the ares of work. All other areas are not in contract and WSFP is not responsibly for existing conditions. I23E3r173 13 on EXISTING PIPE NEW PIPE SYMBOL LEGEND EAST RISER DETAIL HYDRAUL-IC REFERENCE ONLY NOT TO SCALE REVISIONS 1 1 J 1 1 1 1 1 1 1 1 i1 1 J ----- Ordinary Group II.0.200gpm/ft2 for 743.O0ft2 CEILING HEIGHT TO BE 14-0" AFF UNLESS OTHERWISE NOTED SHARKY'S Remote Area: Retail # 2600 FC -02 k CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II IMAX. COVERAGE per HEAD 130 FP t DENSITY .20 GPM l Ft' for 743 FN SPRINIQER Reliable Model G4A/ F1FR (ORIFICE 1/2" K. 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER. SYSTEM REQUIRES: _GPM(5'9.7 PSI SHARKY'S FC -02 - TI Sprinkler Legend • At lime of Design 2 -WAY EARTHQUAKE BRACE ND. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR.IMODEL 3 5 7 9 11 .:TYPICAL FLEXABLE SPRINKLER CONNECTION: MOUNTING BRACKET SPRINKLER HEAD FLEXHEAD DETAIL NOT TO SCALE, FIG. E09 SWIVEL SWAY BRACE FITTING BRACE PIPE 318" KWIK BOLT (2 IW EMBED LENGTH) FIG.IODO - "FAST CLAMP" SWAY BRACE ATTACHMENT LINE PIPE LATERAL LINE RESTRAINTS NON•THREADED BRACE PIPE FIG.4A PIPE CLAMP FOR SWAY BRACE 3/B" KW I K BOLT (21/4' EMBED LENGTH) FIG.909 NO -THREAD SWIVEL SWAY BRACEATTACHMENT i LATERAL BRANCHLINE RESTRAINT BRACE PIPE 5iunfnl NON•THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt IH Cut Rod Lgth Rounded to Nearest Inch Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE FILE COPY 00 Without Comments A5 Noted In Lied Per The Attached Letter 1 nese plans hav I, ;,:r1 reviL:v'rd by Til; Tu,;qib Fire Prevention'iI..Iri_,au. I:C:, fro! !li;,l'iCi? 1'•1:�i1 CU(te?;lt CitV standards. .;,.c;.4t ,..-•nL::: is r+: 0lUro ni.:(t OmISSi011S 41?lic:i) no r.., el.i`?•'i;i...., ,itC C,: ..:.;,iopi:E3d stanaards EII d .. .... >.,,-� h:; fc ,r .. ,I, :;t,: ,:.r the adequady :,)i . .il. ,mill ,,,, _,.aril ilia. /Additions, di:. i'. A,; ti iUS(i dr:.,i igs atter this date will'.o' l.hi.; [/,.:o:pi 1:ICe r,,,rd will require a • resubmittal of revised drawings foe subsequent approval. Final acceptance k subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: ,S -`ani -02 .By: VICINITY MAP DETAIL NOT TO SCALE UKWILA FIRE DEI -'AR I Mt;�fvs Please call: 575-4407 and give this job No. b$-5-)}3 lira* and exact address for shut' :sown or rest.aration approval. OTECE Weld stamps must be inspected before pipe is hung. 1.2p not paint piping prior to hydrostatic test approval. PAID E".'': 3 2 3 2008 Tukwila Fire �Tltop `S U z WESTWOOD CONTRACTORS • I- 0 0 0 APPROVAL: CITY OF TUKWILA 4 -WAY EARTHQUAKE BRACE 6 5.6 Pendent Brass 212°F REL G4A HYDRAULIC REFERENCE POINT R5415 4 5.6 Pendent Brass 155°F REL G4A CONT. NO.: K$0414 HANGER SYMBOL R615 5 5.6 Pendent Chrome 155°F REL F1FR SSP DRAWN BY: C. ISAAC BRANCHLINE RESTRAINT 2 5.6 Pendent w Brass 286°F VIK M STD ADJ QR DRY SPRK. ON SHEET: SEE LEGEND Total =17 SPRK. ON JOB: DATE: 05/23/08 Western States Fire Protection Company 7102180th AVE NE, STE A-105 - REDMOND, WA- 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS( DECATUR/DENVER/DULUTH/HOUSTON/KANSAS CITY LAS VEGAS IMINNEAPOLIS / PHOENIX/PORTLAND 1 RAPID CITY)ST. PAUL/SALT LAKE CITY /SEATTLE Phone:425-881-0100 Fax:425-881-3030 S HARKY'S 2600 SOUTH CENTER MALL FC -02 TUKWILA,WA 98188 SHARKY'S FC -02 TI SHEET FP -1 OF 1 SHARKY'S FC -02 lirjTa .4 11le Nraj ��� IO�. ylll lE �� ,tai _ �-',,,,"'' I1I0I��nP'��I 1111 �! I L ':. IIS •� ice',! 1�atiu ���11�1masi el _ iii iii ii MN 011 �1 _- fraraW 1 111, ow A, ^ immil i olaii 11aalga `. 1rlr-6 General Notes VICINITY MAP (Suite#2600 FC -02) SC:ALt: N 15 1. Western States Fire Protection to add new pendent heads new and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The buildina is constructed with non-combustible materials and aualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA. as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for free7ind conditions 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. EXISTING PIPE El NEW PIPE Eg EAST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE (?o swam'® �'� ® tee: 1.6 ®A r .s4300.2. ' ■L DN1x9' 8'-0" AFF d'?� o , A1.02 001.0 8-1 AFF ®A..I 1'-9 • 1 05 DN1xs:rb 0 •u .1.11 o? 10'-8' • 10'-0 AFF H ct 10'-G AFF ,`:` �• o q WALK IN COOLER_Usti p . • 1 nrf to \ e K" 'S p 6 �i �N .2,+ �.T' .0. 4' m.0 i� St fD 0 r c N 0t.,„' 107 10'-0 AFF 0 II CM 1'-3 '- CEILING HEIGHT TO BE 14 -0" AFF UNLESS OTHERWISE NOTED SHARKY'S RemDte Area: Retail # 2600 FC -02 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Fc' DENSITY .20 GPM / Ft' for 743 Ft' SPRINCLER Reliable Model G4A/ F1FR ORIFICE 1/2° K. 5.6 WATER FLOW INFORMATION*: STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 358.4 GPM CI 58.7 PSI SHARKY'S FC -02 - TI " At time of Design TYPICAL FLEXABLE SPRINKLER CONNECTION": • FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLIKE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE FIG.909 SWIVEL SWAY BRACE FITTING OI 318' KWIK BOLT (2 IW EMBED LENGTH) FIG. 1000 "FAST CLAMP" SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE FIG. 4A PIPE CLAMP FOR SWAY BRACE 318' KWIK BOLT (2I/4' EMBED LENGTH) FIG.909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT LATERAL BRANCHLINE RESTRAINT lag] NON•THREADED BRACE PIPE LATERAL BRANCHLIKE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III Rod Coupling —� cut Rod Loth Rounded to Nearest Inch Q All Thread Rod CL Swivel Ring Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE w 0 WESTWOOD CONTRACTORS INC CONTRACTOR. SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE 6 5.6 Pendent Brass 212°F REL G4A APPROVAL: CITY OF TUKWILA HYDRAULIC REFERENCE POINT R5415 4 5.6 Pendent Brass 155°F REL G4A CONT. NO.: KS0414 R615 5 5.6 Pendent Chrome 155°F REL F1FR SSP DRAWN BY: C. ISAAC HANGER SYMBOL 2 5.6 Pendent Brass 286°F VIK M STD ADJ QR DRY BRANCHLINE RESTRAINT Total = 17 SPRK. ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 07/21/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE /AUSTINI DALLAS I DECATUR / DENVER / DULUTH / HOUSTON /KANSAS CITY LAS VEGAS l MIIWEAPOLIS / PHOENIX / PORTLAND, RAPID CITY/ ST. PAUL /SALT LAKE CITY/ SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 SHARKY'S 2600 SOUTH CENTER MALL FC -02 TUKWILA,WA 98188 SHARKY'S FC -02 - TI SI!EET FP -1 OF 1