Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 2600 SOUTHCENTER MALL FC-3 - SARKU JAPAN - PERMITS AND PLANS
2600 SOUTHCENTER MALL FC -3 FOOD COURT ASSOCIATED PERMITS 19-F-044 08-F-112 08-F-097 19-S-037 19-S-035 08-S-114 19-H-049 SITE LOCATION ,21,00 Site Address ,�I l \/,:[..�( it{X eN �L1, r:C'� Suite Numbei Floor: Tenant Name: iL� a t_t tic\(c) (UJ\ New Tenant? El- Yes j - No R.t�\ Property Owner's Name: VN.i 6(3, r"".,( C YeX 43 ` c - C • Mailing Address: C3C) `jtT O (\ZVW13eXC3 l.A q2b l3 City State Zip CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.:0 D 1M \ CONTACT PERSON -if there are questions about the submittal. Name( \ /ck C.Pf1 KC I% IA'01/1_ Day Telephone: kao.)4,15-5b4fp Company Name: uctic \Qi& ,%ity i �L t 3,,-\br ,`J Mailing Address:VA**i) e`^ AV'P , 6 J fyy-t x-1111 A aqA' ). City State Zip Fax Number: ntrBusiness City number: ." ®CAn2q3S+ NICET III number: Business License number: J �-1 E-mail Address: Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ t 2-Crb Scope of Work (please provide detailed information): Cmmcwo\ibc\ - ack i (�) PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. AICA BUILDING OW R OR AUTHORIZED AGENT: Ff-71 ?B' Signature: ` k C TUKWILA eiR Daterl `ct ry t1"t Print NamS,t 3 (rei Voi cvc s u 1A- Day Telephone: Pa Q) OS- i Plan Pennit App.doc 8122/14 TFD FP Form 8 410044 4tt CITY OF TUICWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted fur plan review. **PLEASE PRINT** SITE LOCA ION` _l King Co. Assessor's Tax No.: Site Address: JCI,tha T*k ' rika ! Suite Number: Floor. Tenant Name: G rkt) Japri New Tenant? ❑_ Yes ❑ - No Property Owner's Name: lA -G r y Mailing Address: Scv-fitiCerikY Mai 1 • Tu bu I la / 1.0A - City State Tap CONTACT PERSON -if there are questions about the submittal. Name:3.'ed‘COL.0) n5On Day Tom: 142.G •'-[ S '761 (09 Company Name: effbviY1 Th'hctiYi, 1 G Mailing Address: ri s a // i )1 C Y?i � 9S'd 32. C�1YYI cgy State Etp E-mail Address:3.e.icaecrotAm-C-p. Fax Number: C011ifiCiDeS City of Tukwila NICET III number 97941 /pql • �C� B mss License number: 81 2.5 • o07474,9/Z Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 250 :--- Scope of Work (please provide detailed information): 0 5f "Irl /4 r- h PERMIT APPLICATION NOTES Vale of Construction — b all cases, a value of constitution amormt should be erred by the applicant- This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid uolessd a work on the site authorized by such permit is commenced within 180 days alter its roe, ix ffthe work authorized =the site by such permit' is suspended or abandoned fora period of 180 {lays atter the time the work is commenced. The Fire Marshal is authorized to grant, in .. writing, one or more extensions of time for periods not more than ISO days each. The extension shall be tequested in writing• and justifiable cause demonstrated, I HEREBY CERTIFY THAT I HAVE READ 4ND EXAMINED MRS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZ JJ AGENT: Signature - Print Naine ignature:I ntName 7eS5ICa. braes -7 Plan Permit App_doc 822/14 'Daft: 2•(o•11 ictiyirdephow • •Xdoq `NFDFPFain8- 44.ttiLW444 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: W6s1F i6c.{a 1 2600 SOOTC i (L. F1t4u, Suite Number: FC Floor: 2 Tenant Name: Property Owner's Name: F Mailing Address: 2600 r6 -e, 8 '0 - CONTACT PERSON -if there are questions about the submittal. Name: 0 PC 4-t n V/19-51-6 l f Cj IC -i Company Name: K T Pao l> New Tenant? ❑ - Yes ®- No City State Zip Day Telephone: 206 - - a 5110 Mailing Address: G100 i 2V, iWt _ S LS (,✓ A g g 10 g City State Zip E-mail Address: C N T*1-� . ® 'P -T Ka01% CONI Fax Number: 206 - 464, 26o" Contractor's City of Tukwila U S — 05')S � �S� NICET III number: Business License number: Total number of new/relocated devices or sprinkler heads: (% Valuation of Project (contractor's bid price): $ 4• I oo Scope of Work (please provide detailed information): RC- SCP -E of 2.. (Two) h44.) 1JkL P�� � ; o►J PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in )J writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WAI-LIJGTON, AND I AM AUTHORIZED TO APPLY r� FOR THIS PERMIT. MAR 1:."! 2719 Signature: TUKWILA FIRE Date: i'/ 4 (1 1) Print Name: 2 rk� [ 1111 LDaay Telephone: 206- 4 2,6 - 0 3 1 a BUILDING OWNER OR AUTHORIZED AGENT: Plan Permit App.doc 8/22/14 TFD FP Form 8 LA) FiLE FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Sarku Japan 2600 Southcenter Mall # FC -3 Permit No.: 08-S-114 Date: April 8, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. taxa / Fire & Security R-102 RESTAURANT SYSTEM NOZZLE COVERAGE SUMMARY SHEET F I81.IARESUL:) Appliance Nozzle Type Flow Points Width (In) Max. Side Length • (In) Max. Side Multiple Nozzle wo/Drip Board Area Sq. In. Multiple Nozzle w/Drip Board Area Sq. In. Min. Nozzle Ht. (in) Max. Nozzle Ht. (in) Fryers without drip boards 230 2 14 15 — — 27 47 Split or No Split Vat 245 2 14 15 — — 20 27 Fryers without drip boards • 290 2 19.5 19 — — 13 4 • 16 Non -Split Vat (ONLY) 3N 3 19.5 19 — — 21 , 34 3N 3 18 18 — — 25 35 . Fryers with drip boards 230 2 14 21 210 294 27 47 Split or No Split Vat' 245 2 14 21 210 294 20 27 Fryers with drip boards' ^ 290 2 19.5 25 3/8 370.5 495 13 . 16 Non -Split Vat (ONLY) 3N 3 19.5 25 3/8 370.5 495 21 34 3N 3 18 27 3/4 324 497 25 35 Tilt Skillet/Braising Pan' Coverage limitation are based on fryer sizes including the drip boards. Exception Tilt Skillets and Braising may exceed the maximum of 6 sq. ft. Range 1N 1 12 32 — — 30 40 Without back shelf 1F 1 12 28 — — 30 50 With back shelf 1F 1 12 28 — — 40 48 245 2 24 28 — — 40 50 Without back shelf 260 2 24 32 — — 30 40 With back shelf 260 2 12 32 — — 30 40 2 xC90 4 36 28 — — 15 20 Griddle : . 1N/1NSS 1 36 30 — — 35 40 290 2 30 24 — — 30 50 60 2 48 30 — — 30 50 290 2 48 30 — 20 .30 2120 2 48 30 — — 10 20 Chain Broiler' (Overhead Protection) 2 x 1W 2 34 30 • — — 10 26 Chain Broiler (Horizontal Protection) 2 x 1N 2 31 43 — — Front edge; above the chain 1 in. - 3 In. Char Broiler Gas -Radiant 1N/1NSS 1 24 36 — — 15 t 40 Electric 1N/1NSS 1 20 34 — — 20 50 Lava -Rock 1N/1NSS 1 13 24 — — 18 35 Natural Charcoal ' 1N/1NSS 1 12 24 — — 18 40 Lava -Rock or Natural Charcoal ' 3N 3 24 30 — — 14 40 Wood Fueled' 3N 3 24 30 — — 14 40 Upright Broiler 2 x 1/2N 1 30 32.5 Front edge; Salamander Broiler 2 x 1/2N 1 30 32.5 — above the grate 1N 1 16 29 — — — — 1 N nozzle location to be on the vertical edge 6 to 12 in. in front and 0 to 12 in. above the top of broiler Internal Chamber 1N 1 16 I 29 — — 6-12 In. above either end Wok 3.75 to 8 inches deep 260 2 14 in. to 30 in. diameter — 35 45 3 to 6 inches deep 1N/1NSS 1 11 in. to 24 in. diameter — 30 40 ,' For multiple nozzle protection of single fryers, see detailed information on pages 4-10 to 4-11 of manual. ' See Figure 1 for nozzle Location. ' Minimum chain broiler exhaust opening – 12 in. x 12 in. (31 cm x 31 cm), and not less than -60% of internal broiler size. 4 In. (102 mm) maximum fuel depth. u In. (15 cm) maximum fuel depth. FILE COPY Fire & Security R-102 RESTAURANT SYSTEM NOZZLE COVERAGE SUMMARY SHEET ANSULA Plenum 'Single Nozzle Type Flow Points Width (In) Max. Side Length (In) Max. Side Nozzle Placement (See Manual for More Detail Min. Height Max. Height Hb nzontal=Protection Bank 1N 1 46-- 120 0 in. - 6: in. from end of plenum 2 4 Perpendicular Protection Single Bank 1 W/1100 1 48 48 See Manual for more detail 1 20 Horizontal Protection V -Bank 2 x 1N 2 48 120 0 in. - 6 in. from end of plenum 2 4 Horizontal Protection V -Bank 1W/1100 1 48 72 0 in. - 6 In. from end of plenum 1/3 the height , of filter Perpendicular Protection V -Bank 1W/1100 1 48 48 See Manual for more detail 1 I 20 Duct Nozzle Type Flow Points Perimeter (In) Diameter (In) Nozzle Placement (See Manual for More Detail) Duct Length (In) Single Nozzle 1 flow nozzle 1100 1 50 16 See Manual for more detail Unlimited Single: Nozzle 2.6w:nozzle. 2W 2 100 31 7/8 Sea Manual for more detail Unlimited Multiple Nozzle 2W +1100 3 135 48 See Manual for more detail Unlimited Multiple 2W Nozzle 2W — >135 >135 See Manual for more detail Unlimited R-102 OVERLAPPING PROTECTION The 245 nozzle, Part No. 419340, is the only approved nozzle for overlapping (zone) protection. Appliance Type Fryer Griddle Range Wok, Maximum Wok, Minimum Braising Panfrilt Skillet' Lava Rock Char -Broiler Charcoal Broiler Mesquite Wood Broiler Gas Radiant Char -Broiler Electric Char -Broiler ' See Figure 1 for nozzle location. Maximum Cooking Hazard 34 in. (864 mm) Deep x 5.8 sq. ft. (.54 sq. m) 30 in. (762 mm) Deep x Unlimited Length 28 in. (711 mm) Deep x Unlimited Length 30 in. (762 mm) Diameter x 8 in. (203 mm) Deep 11 in. (279 mm) Diameter x 3 in. (76 mm) Deep 34 in. (864 mm) Deep x Unlimited Length 32 in. (813 mm) Deep x Unlimited Length 32 in. (813 mm) Deep x Unlimited Length (4 in. (102 mm) Maximum Fuel Depth) 32 in. (813 mm) Deep x Unlimited Length (12 in. (305 mm) Maximum Fuel Depth) 36 in. (914 mm) Deep x Unlimited Length 34 in. (864 mm) Deep x Unlimited Length TYCO SAFETY PRODUCTS, ONE STANTON STREET. MARINE I IL, WI 54143.2542 COVER MUST NOT INTERFERE WITH EDGE OF DISCHARGE PATTERN II 0-6 IN. (0-15 cm) II I ! r 1 1 ZONE twww%www%N►www%. 1iI ZONE CENTER LINE 40-45 IN. (1-1.1 m) 006921 FIGURE) 715-735-7411 Form No. F-2005010 02005 Ansul Incorporated Litho In U.S.A.. SECTION IV — SYSTEM DESIGN ► UL EX. 3470 ULC CEx747 Page 4-34 7-1-98 REV.4 ANK AND CARTRIDGE REQUIREMENTS Once the hazard analysis le completed and the total nozzle flow numbers are established, tho quantity and size of agent tanks and cartridges needed to supply the nozzles with the proper volumes of agent nt the proper flow rates can be determined, For cartridges used in the regulated release mechanism, flow capacities, tank quantities and sizes, and regulated release cartridge options are given tri the table below. Total Quantity and Regulated Release Flow Size of Cartridge Options Numbers• Tgnk(s) Nitrogen Carbon Dioxide 1 — 5 (1) 1,5 Gallon LT -20-R (7032) 101-10 (15850) 6 — 11 (1) 3.0 Gallon LT -30-R (5373) 101-20 (17492) 11 — 15 (1) 1.5 Gallon Double (73022) 101-30 (15851) (1) 3.0 Gallon 16 — 22 (2) 3.0 Gallon Double (73022) 101-30 (15851)\lk *When one or more regulated actuators are used, the following tank and cartridge combinations apply for each regulated actuator: Regulated Actuator Regulated Actuator Tank(s) Cartridge (1) 1.5 Galion (1) 3.0 Gallon (1) 1.5 Gallon and (1) 3.0 Gallon ► (2) 3.0 Gallon LT -20-R or 101-10 LT -30-R or 101-20 LT -A-101-30 or 101=30" LT -A-101-30 or 101-30" —'or exoepllone to maximum How numbers, see Distribution PlpIng Requirements Ior 1,S gal• 1 and 3.0 gallon systems In Ihla secllon. For higher total flow numbers (23 to 110), multiple cartridges and regulated actuators are required as shown In the System Selection Guide in Section IX — Appendix. ACTUATION GAS LINE WITH AN LT -20-R, LT -30-R, 101.10 OR 101.20 CARTRIDGE MAXIMUM LENGTH OF 20 FT, (0 m), MAXIMUM NO. OF FITTINGS 0 "ANSUL AUTOMAN" REGULATED RELEASE ASSEMBLY • ACTUATION AND EXPELLANT GAS LINE REQUIREMENTS Thle section contains the guidelines for installing the actuation and expellant gas lines between the regulated release mechanism reg- ulator, each regulated a.otitator regulator, and each agent tank. These limitations should be considered when selecting the com- ponent mounting locations. r Actuation Gas Line — 6 to 6* Tanks Maximum ► • 8 Tank maximum reflects the utilization o13 tank regulated actuators. 1. Use only 1/4 In. Schedule 40 black Iron, hot -dipped galva- nized, chrome -plated, or stainless steel pipe and fittings. 2. The actuation gas line piping is installed from the regulated release mechanism to each regulated actuator connected within the system. The total length of the actuation gas line from the regulated release assembly to the regulated actuator assembly(les) must not exceed 20 ft. (6 m) when using an LT -20-R (Part No. 7032), an LT -30-H nitrogen cartridge (Part No. 5373), or a 101-10 (Part.No" 15850) or a 101-20 (Part No. ► 17492) carbon dioxide cartridge. See Figure 73. REGULATED ACTUATOR ASSEMBLY EXPELLANT OAS LINES NOT INCLUDED IN ACTUATION GAS LINE LENGTH TOTALS FIGURE 73 003775 • \� \ 2 0 0 0cp 0. 3 0 \ C waaln of papauuoa ivays s s Otr ainpayos Naaiq si acid Iv s :31ON paool aq }snw alzzou wnuald s II i II I I iI 36" X 24" GAS RANGE 1 *�1 , . - � ]o\ ��\ 2 e 3l�fW 2131N3DH1f1O NVdV f1H21VS -rind 1VflN W W „OS -017 „OS -017 \ t NO -11V0 E \ k ----- S>11\111 3Sf13.09E -D 0 M§_ }\ \m 0Z a x/ §�2$ o > o /\9 \ ob /2k = ) 11 o Iona ..Z pm I. \ /_ 0 6 111 • 4. a a • D c o o C211' CT 7 0 a 0 0 5- 33 7 CD .< c o cD -a 3 c cn WA co 24" X 24" GAS GRIDDLE • • • • A c z 0 r- 2! +0 0) 0 c ...-------- Iona z P(0 i• 62 -75 6 M01.1 ivnio PAH) 2 1. 2008 Tukwila Fire • • * 0 • 00 • 2 A) > ,. .... - 5 V) > -o - • • <> • • • • • • • A c z 0 r- 2! +0 0) 0 c ...-------- Iona z P(0 i• 62 -75 6 M01.1 ivnio PAH) 2 1. 2008 Tukwila Fire ACCEPTED ❑ Without Comments As Noted In Red Per The Attached Letter nese plans have been reviewed by The Tukwila Fire Prevention Bureau for coriforrnance with current city stan.dards. Acceptance is ?uhfect to errors and omissions which do not authorize, violations of adopted star aaros and oroinances. The r e.ponsibOy for the r' adequacy of design rests totaffu 4,11 s toe designer. Additions, del ;'ions or , ti.hs;on. ,_ ineee drawings atter this date will void thiei.ac ;eptan ce 9 -id will require a resubmittal of revised ciravtiings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire. Prevention Bureau. Date: c/ -1- O g By: 11l or _t —S11vh+ +r;r 4i ctiso ihotv44 eler;+r;c l .511A—of-F. — 5 \vhf- +r;p iv 4 #rM* oc wrkic-c tie q;r et .1 e tutus4 S1 U.L. i't s 1-vr.„ 1 s A-i;,.i po" -fuer-) re v:1 -c, 4. I UKWILA FIRE DEPARTM .Lfl Please call: 575.4407 and give this job No. OR- and R- and exact address for shut. sown or restoration approval; • 0 §C\ §§j o .Lu §kutLk 2§�§ cd&/ =0 to0 0 0 _ k • #/ O • Ef)f ±kkIt) $ ; b£ ${R° iq al §)f E£ Ef• «2t 0. {t& ACCFT 0 Without Comments As Noted in Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance vvith current City standards. Acceptance is subject to errors and ;missions which do not authorize vio ations of adopted standards and ordinances, The responsibility for the adequacy of design rests totally with the designer. Additions, deletions: or levisions to these drawings after this date will void thL; a -c pptance and wiii require a resubmittal of revised drawings for subsequent approval. Final acceptance is, suoject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: -141 By: 1 I TUKWILA FIRE DEPARTMENT F Please' call 2S6-575-4407 and �d give ti -L; Fim Para No. 19 -1� and exE c:;iddress for shut- down hutdown or restoration approval. Feb 2619 03:02p Crown Fire Protection I FAX TRANSMITTAL 4254818695 p.1 Fax No. CROWN FIRE PROTECTION, INC. MEM 2.26.19 Fire Prevention Bureau Tukwila Fire Department / Al Demo Permit \unrbur of Parc" (InclutlinLv, Cup cr ) 1 1206.575.4439 0 Urgent EB For Review 0 Please Comment ❑ Please Reply F ronr Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comment We need a demo permit for 2600 Southcenter Mall FC03 in the Sarku Japan space. The General Contzactor needs us to demo 4 sprinkler heads out of a soffit they are moving. The building permit number is D18-0384. Tl>anks- oMr AiMMT► PIwe PROTECTION BPRIWMAR SYSTEMS John Thorns aeMsrlina 9794-1001-C43 Level 3 Crown Firs Protection, Inc. I. w. uiiutliLA FIRE l E?ARa 1 lv1C:.:laT call 206-575-4407 and ova this Fire Permit No. /9-3-03 - and exact address for shut- down hydown or restoration approval. ■ ■ ■ P.O BOX 12ht3 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8695 13 Without Comments p As Noted in Red p Per The Attached Letter These plans have been reviewed by The. Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance i, subject to errors and omissions which do not authorize violatio! Is of adopted tandards and ordinances. The responsihliicy for the idequacy of design, ; a.F.:, totally with the designer, Additions, deletion s v6slorys to these drawings after this date will void um:- and will require a resubmittal of cnwinos for subsequent approval. Final acceptance: ! suojeci to field test and Inspection by The Tukwila Fire Preventio(? Bureau, Date 3-1)- "/ B. lk ftUic.;/ IA FIRE DEPARTMENT 2:C5-575-4407 and CJ th31� ere P rni't o. and exact address for shut- down hutdown or restoration approval. FIRE ALA u M S s` STEM SHINS 1==° DITION N SHEET \ U V 3E. SHEET TITLE FA -01 SYSTEV \FO' V ATI O FA -02 TYPICAL WI G A\3 V OU\TI\G DETAILS FA -03 SYSTE V CALC U LATI O \ S A\D SI\GLE LI\E 3IAGAV FA -04 FRE ALAN SYSTEV PLA\ SHEET INDEX ADD 3 NEW CEILING MOUNT SPEAKERSTROBES, 1 NEW WALL MOUNT STROBE & 1 NEW MONITOR MODULE ONTO AN EXISTING FIRE ALARM SYSTEM SCOPE OF WORK WRE SCH RULE A\D CO\ D U IT FILL CHAT SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END EXPIRES 09/01/2020 FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NEPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 3 E E E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP FIRE ALARM STROBE (NEW) ZR -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2 EXTN CEILING HT -D DUAL INPUT INTERFACE MODULE (EXISTING) HTRI-D SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DDT (EXISTINGETECOR) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY (EXISTING) HTRI-R SIEMENS 4S BOX VERIFY IN FIELD TENANT �E J -BOX F.B.O. F.B.O. VERIFY IN FIELD END-OF-LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N /A N/A N/A E EXISTING DEVICE N/A N /A N/A N /A F.B.O. FURNISHED BY OTHERS N/A N /A N/A N /A N /A NOT APPLICABLE N/A N /A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N /A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND SARKU JAPAN 2800 / SPACE# FC -3 ES n..Atal 0 1264 0. 0 w 0) i 1 FC161 U n:. ,..w 0 ktJ 7 0) o y 0 .) a0) c> nr FS 22120 1G NI2 i zsl - 0 121301 a n nitil THAI GO 0 0 0 0 1R:11 JOHNNY ISHai KVS / r -F a n 07:00 0 0 0 21551 41.0j :r 0 122051 0 /Eg.1 1 ° BAYOU GRILL >a v. WIRE DESIGNATION GENERAL NOTES SITE PLAN a PAID FEB 23 2019 TUILA ARE Cie TOR F , 4io co 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS . VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END EXPIRES 09/01/2020 FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NEPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 3 E E E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP FIRE ALARM STROBE (NEW) ZR -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2 EXTN CEILING HT -D DUAL INPUT INTERFACE MODULE (EXISTING) HTRI-D SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DDT (EXISTINGETECOR) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY (EXISTING) HTRI-R SIEMENS 4S BOX VERIFY IN FIELD TENANT �E J -BOX F.B.O. F.B.O. VERIFY IN FIELD END-OF-LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N /A N/A N/A E EXISTING DEVICE N/A N /A N/A N /A F.B.O. FURNISHED BY OTHERS N/A N /A N/A N /A N /A NOT APPLICABLE N/A N /A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N /A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND SARKU JAPAN 2800 / SPACE# FC -3 ES n..Atal 0 1264 0. 0 w 0) i 1 FC161 U n:. ,..w 0 ktJ 7 0) o y 0 .) a0) c> nr FS 22120 1G NI2 i zsl - 0 121301 a n nitil THAI GO 0 0 0 0 1R:11 JOHNNY ISHai KVS / r -F a n 07:00 0 0 0 21551 41.0j :r 0 122051 0 /Eg.1 1 ° BAYOU GRILL >a v. WIRE DESIGNATION GENERAL NOTES SITE PLAN a PAID FEB 23 2019 TUILA ARE Cie TOR F , 4io co 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 0) N 0 2aaaaa Z 0 0 z SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/ 15/ 19 BACKROUND PLAN PROVIDED BY: Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved .OB NUMBER: 3801 1-1; SHEET .0 FA -01 .All 120VAC-6014Z - DEDICATED EMERGENCY THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL FROM EXISTING MAIN FACP C CABLE C' CABLE 0 0EIE1 ORD N C T T T T 0 PAD -3 0 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 uN& 3.6k EOL 0 u 0 1_01 0 0 0 (-) (+) (-) (+) NAC S4 NAC S3 NAC S2 j NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL HARD LID CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE ° o°. o SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) (+) ( ) STROBE SPEAKER (+) (_) 1� U (+) ST ) ROBE (+) ) STROBE SPEAKER (+) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE HFP-11 N / TB1 1000®�©� ® 0 1D NO COM NC TO FAN SHUTDOWN EOLR 470 SWITCH + INPUT LED TSM -1 00 0 TO NEXT ADDRESSABLE DEVICE 0 3 4 00 HTRI-R 0 NO B COM ® NC (9 ^ Q 0 o/2) TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL TO NEXT DEVICE OR END OF LINE TO EXISTING DATA LOOP 0 0 e Lei /MI 2 3 4 5 00 HTRI-D 7 6 e o /2, KITCHEN HOOD MONITOR KITCHEN HOOD MONITOR WIRING DETAIL EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 17 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: o M 0 DESCRIPTION SHOP DRAWINGS DATE 0, Lo N 0 C U ZU LU 10 Z 1_QO) <^ og3E0 1� J� Lji D Cr) wi9 CC CC < cn Q=_ LLO� 0 N (zI SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/15/19 BACKROUND PLAN PROVIDED BY: .,JOB NUMBER: 3801 1 -1 J SHEET FA -02 A B C D E F G H I .1 K FIRE ALARM BOOSTER Project:SARKU JAPAN Panel: EXISTING BPS PAD -3 Date:: February 15, 2019 Module/Device POWER REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 =TOTAL FIRE ALARM POWER SUPPLY 15: 140 ;Auxiliary Device Current ! 0; 0 Notification Appliance Load (Max. Total / mA) 0 3397 i Tatal(A)=; • 15 Total(B)7 3537 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 3537 Total current ratings converted to amperes (line D x .001) 0.015 3.537 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 2 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.2946321 Add lines G and I Total Standby and Alarm AH 0.6546321 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.78555852 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP -HOUR *** Notification Appliance PROJECT: SARKU JAPAN Panel: EXISTING BPS PAD -3 REMOTE POWER Date: ;February 15, 2019 Circuit Detai SUPPLY W i re Resistance 2.58 CURRENT TOTAL= 3397.00 SET -MC -CW 75ct% SET -MC -CW (295cd ZR -M -CW @1Scd To l W i re Resistance . ( R ) .Total Device Load ,Amps (l) 1etg Drop e 200; 264 69. TOTAL mA= 397 :EOL Vol Wt.* 2 ) (Total Cct Lx ad) (E=l*R) ".v. 24-E) 1A7 0.40 0.58 23.42 SET -MC-' .SET -MC -ON SET -MC -CW S ET -MC -CW -Cwai5co_ DE1f}CES MAXIMUM LOAD 200 264 69 TOTAL mA=' ;TotaiWire Resistance C R ) fobt Device Lsd, Amps (i) ;Voltage Drop ( E ) 1500 24.00. J'L*.2.)(Ft tft) 'ota't c1 ;! $ )..... =1�R) 24E 1500 0.00 1.50 SET -MC -CW 15c SET -MC -1 03Ocd, S ET -MC -CW ©75cd 3ET-MC- N 095cc SET -MC -W Q11Ocd ZR MC -CW t 3{lcd DEVICES MAXIMUM LOAD 69: 111 200 264 233 111 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (l.) Voltage Drop (E EOL Voltage a! 0 a a, 24.00; (W L x 2) / (RtIt) (Total Cct Load) (E=I*R) 24-E) 1500 24.00 CALCULATIONS TO EXISTING SPEAKER CIRCUIT TO EXISTING BPS REMOTE BOOSTER POWER SUPPLY TO EXISTING DATA LOOP s,v S )001N( S1-1 30Cd D S1-2 30Cd HT -D S1-3 15Cd V D S1 -4 30Cd KITCHEN HOOD MONITOR EXISTING TENANT J -BOX SINGLE LINE DIAGRAM FLAG NOTES: HTRI-D MODULE FOR KITCHEN HOOD MONITOR. MOUNT STROBE ABOVE THE KITCHEN HOOD MANUAL PULL STATION. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ASH INGTON 1743 IST AVE. SO., SEATTLE, FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 0) T Y ! N 0 2 aaaaa "GALE: NOT cc 0 0 w z W z C!� 06 (1) z 0 E -- -J5 U U W F- C/) >- (J) TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/ 15/ 19 BACKROUND PLAN PROVIDED BY: \0B NUMBER:3801 1—/ SHEET FA -03 EXISTING ELECTRICAL PANELS 8'x 12' WALK-IN COOLER TO EXISTING TENANT JUNCTION BOX s,v 0 PREP. s,v EXISTING EXHAUST HOOD S1-2 30Cd D rJ rJ T; W l� 1 a 2 ANSUL CABINET f FR .mmmti ra gr11 Hieatiitvti :mom T -D 4 S1-3 1 5Cd Vii///////. e) S2-4 30Cd SERVICE II I FIRE ALARM SYSTEM PLAN of FLAG NOTES: HTRI-D MODULE FOR KITCHEN HOOD MONITOR. MOUNT STROBE ABOVE THE KITCHEN HOOD MANUAL PULL STATION. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. AH Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE rn uo N 0 2 aaaaa M 0 u_ z co ~ Q °' < 0 �; z W -42 CC CCz� ©CQ=_ CD w H- LL cc 0E— O O O N /SCALE: 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:02/15/19 BACKROUND PLAN PROVIDED BY: \0B NUMBER:3801 1-1j SHEET FA -04 1 E A A T KW ', ; A, As SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTErV INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL) FA -04 FIRE ALARM SYTEM FA -05 WESTFIELD SOUTHCENTER MALL SITE PLAN WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO 1416 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD 1412 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR : RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWO #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DMA TWISTED PAIR RATED , #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED 1418 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH• 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED . ON . 40% CONDUIT. FILL: AND ARE TAKEN FROM "N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED: 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED; . NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE,: FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE; :FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TOCONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR. CODE. CONDUCTORS SHALL BE PERMANENTLY,' AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS., ' 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF. NFPA 70; N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED. .AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR. TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON .A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL -BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH . A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2002 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2002 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 2 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD I" N LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE ®p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING gL C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. ILI FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM STROBE C (CEILING MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" : EXT. 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING a FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. Pc FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1 ;-1/2" EXT.. FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX W/ 1-1 /2" EXT. 80" A.F.F. TO BOTTOM WP MR FIRE ALARM STROBE (WEATHERPROOF) MULTI -VOLTAGE CONTROL RELAY SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2"PIPE IN FIELD. MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD ❑M MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FATC FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. VERIFY IN FIELD JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A UNLESS OTHERWISE U.❑.N. NOTED N/A __ N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A V1Gthoiat Cornments As Noted In Red P The Attached Letter I nese plans have liken reviewed by The Tukwila Fire Prevention Bureau ;or conformance with current city standards. Accect Ince is wu�".,iect to errors and omissions which Uc not authorize violations of adopted standards and or:?+ ;: r: s. 'The rewonsibility for the adequacy of de; v;r rest:::: totally with the designer. Additions, dole ictr s or;sAiisions o these drawings atter this date will voice th •:; acc tance rnd will require a resubmittal of;rovis:,d drrawings for subsequent approval. $Final acceptance is The Tukwila Fire Pr Date: y -g- (). :subject to field test and inspection by :vention Bureau. By: 511 GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A TUKWILA FIRE DEPARTMEN', Please call: 575-440Z and give this job No 08-F -// 2- and exact address for shut down or re:t:,ration approva$7 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result In a Re -inspection Fee and termination of the testing, Y��1( �hoh(tDr�Dc� partsII►o� Loo Svl,pregii'• Sy3J. X1154,4 l l0(IkGV` devic‹. oti o�ediCc41 F4 s. S4cr. etre(-0" %t -e41" -c -- S y s•6, 4 Cop! ui - ' N Fe4 7z loo e d r 1,-o1• _ , 'fl 2008 WASHINGTON 98134 -RELEASE/REVISIONS r CD LLJ CC -- DESCRIFTION- LIJ cb z C C Tukwsla Fire Copyright 2006 by Guardian Security Systems, Inc. All Rights Res ele DRAWN ;i t3Y:: I.ANDERSbN. DESIGNED';BY: R.vr ZZAN f DATE: 2/27/0 BACKROUND; PLAN PROVIDED BY: THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT t0'IDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AIR DUCT 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC o o o END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH $., 0 GROUND -0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 HTRI—R OSTATUS LED CO n t0 0 0 0 DUCT DETECTOR LOCATION N.O. COM N.C. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCALE PREVI❑US ADDRESSABLE DEVICE (BACKGOUND MUSIC SHUTDOWN) TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES, MAX. - MAX, CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX, LINE SIZE - MIN. LINE SIZE- OUTLET SAMPLING TUBE INLET SAMPLING—\, TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE MUSIC —1.) -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE {(-) FROM XLS CONTROL PANEL OR 1(¢1 PREVIOUS ADDRESSABLE DEVICE (-1 END OF LINE DEVICE (3.6K 1/4W) / / / SUPERVISED / RELAY CONTACTS SWITCH /% (4.0A @ 125VAC) GROUND ' (4.OA @ 30VDC) 27 VDC 3.5 rnA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0,02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST 25 SEC. TO GUARANTEE DETECTION. JOeI 0 1.23.4.56 HCP TB2 ma 65 -0 0 0 HTRI—D STATUS LED CO 0 0 NOT USED 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 CND N AC 0 El El 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 17, 1 2+ 2-..2 •NC- C N,O +. + - +._-• 1 A 241( TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END OF LINE DEVICE 3.6K 1/4W) `SUPERVISED SWITCH 1 FRONT MEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP ! O O FROM XLS CONTROL PANEL OR (4-)) PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS hi EOL 0 INPU 9 P Jp9 TSM -1 0 CC,(1C0 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL FROM. REMOTE POWER SUPPLY C'S' CABLE) FROM FRCP (VOICE CIRCUIT) ('V' CABLE) SCALE NONE EARTH GROUND ->(+)TO NEXT DEVICE OR 1 >(-) STOP IF LAST DEVICE J W-) �) STROBE SPEAKER. (+) ( ) ( STROBE ( STROBE-) SPEAKER +) � ) SPEAKERISTROBE AND STROBE WIRING LABEL SCALE NAC -4 NAC -3 NAC -2 NAC -1 SPEAKER STROBE OR STROBE ONLY R u 4S DEEP BOX W/ 1 -1/2 - EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERA�T�IN TEMPERA +32.F (0' C TO 100. F C) HUMIDITY: b0--9 % RELATIVE HUMIDITY. NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE {DATA IN (-) >--- DATA IN (-F) > DEUCE IS LISTED FOR AIR VOLOCITY APPUCA11ONS OF 300-4000 FT IN WEN USED IN CONJUNCTION TH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEMCE.ci ( ) DATA OUT (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID HARD LID CEILING -------SPEAKER SUPPORT TILE BRIDGE m LU ti / 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION \.. CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT JUNCTION BOX—, MOUNTED ON \ CEILING FLEX \. / 0 0 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE=NONE --- SUSPENDED ILLUMINATED CEILING Copyright 2006 by Guardian Security Systems, Inc. All. Rights Reserved RELEASE/REVISIONS DESCRIPTION CO CO pj W 0 CC cc OcT) ~< CC CO f t. Z 1 SCALE: DRAWN' BYi (.ANDERSON DESIGNED BY:. R.VEZZANI'; : DATE: 2/27/08 BACKROUND PLAN PROVIDED BY: . JOB NUMBER: . SHEET 2 1111 gEt. ------------ 2V,2S .r.g.Off Ll „„ *11.04.1, i; FfireleiWalff4W4R4 VAIPX170/9(4/AMISMIIIKOSIWAVARIVAIRWIRSMI=Cl 2V.2S —1 30; --------------------- 104, Oren! ; 4 • 1- • • ; • • Copyright 2006 b' Guardian Securit S stems, Inc. All R. hts Reserved •') ;;;;, „ • ; I i• ' : 1;,,, • FAX (206) 628-4.990 •, 1i • I DRAWN . By:, LAN DERSON DESIGNED • BY: R .VEZZAN I • DATE: 2/.27/08 I3ACKROUND PLAN PROVIDED BY: NUMBER: „ . SHEET -03 1., ••• 111' • .1, 4. •I ' ,!!! • ;1:i 11.1 t.t • 11 1 II • 11 I 1 1;1 1 +•1; I • 1,11 • 111 „I 1 .11 t•,; •4; 111 ''.-;t .t,' "'I" „,,;•; . , "", • y" 4i ".,,, ,!. ".! -7 ...,— CD CY';, CJ cn LU 0 ;" •, t'. t,'c it:, 1 4., 7.! ' •''.1., :, 1'. „„,..-t;, r,;:: II ); ; l'.•Iii•,.-t; I; I'";•••:11!, 1" ; - '1' '17: .!.•! !!q' r•'.: •" 7.'".. , ' .,4;-.'; r,f,;'.".„f.., „ .., ... ,•-;... ;•„; 6i, .••'• ' i, •;„;„. • '1: . •1 ' , • ' ' • t ' ,, • , ;I' tiii <C 0 i,I ,tr• ,; ;• "' ,: 1; i 1!„- ', ' • ' • :. , ' . Z 6,„, < •, ,:. <<<< DRAWN . By:, LAN DERSON DESIGNED • BY: R .VEZZAN I • DATE: 2/.27/08 I3ACKROUND PLAN PROVIDED BY: NUMBER: „ . SHEET -03 1., ••• 111' • .1, 4. •I ' ,!!! • ;1:i 11.1 t.t • 11 1 II • 11 I 1 1;1 1 +•1; I • 1,11 • 111 „I 1 ! t --1--, /- , „...------ t.1 d-- -a *•,.. \!, A 1 \ '......,\ ../' v, ,, ir; 1-;,A .....A 1, . t trtt.,..;.....l' . i 1 jj ":"../..., 1, - ---- .---_,- \ ' \ --0; \\'• j --- 0 0 --- ...... \ NORTH CONCEPT 5 WESTFIELD SOUTHCENTER MALL SCALE 1/32":11 {120VAC 20A DEDICATED CIRCUIT BY OTHERS R SER DIAGRAM • SYSTEM CALCULATIONS xxxx RECOMMENDED MINIMUM BATTERY SIZE = 7,00 AmperexHours ATTERY SIZING CALCULATION '`4••11 , Date: !April 3; 2008 • • Notification Appliance Circuit Detail PROJECT: 1WESTFIELD SOUTHCENTER MALL Panel: iSARKU !Wire Resistance 3 24 CURRENT TOTAL= 273 i , 1 CIRCUIT:iS1 ; QTY I Device Type Alarm Currents,' Alarm Total ; VVire Size 1 VVire Length ! Voltage at EOL ' Circuit Total 1 , , I i 64 CO , 1 1 ; i Total Wire Resistance ( R ) 1 0 1SET-MC ©15CD ' 1 4 1.301 ;1 I , • 1.4') 00 0\ 3 IST AVE. SO., SEATTLE, WASHINGTON •1 FAX (206) 628-4990 TEL. (206) 622-6545 0 ET) 5 uJ Lid LU uJ c ,• 14 •=•.;';„:" CC ,.„ ' •,... 0 SET -MC ©110CD 1 0 1 : )SET -MC ©75CD 4 iZR-MC ©15CD 1 t " ; _2331 175 98! 1 _ 0 175i s 1 I , - 4 , 1 , t 1 .; ? 1 ;Total Device Load, Amps (1) I i , 1 (Total Cct Load) .. , t 0c:2375 if!' . t 1 SET -MC @30CD i 98i i t ; , t i 1 { ( WL * 2 )* (R/ft) 641 Oi ; 1 ; I -t ;Voltage Drop ( E ) ., ;;;;; 0 ZR-MCi@30CD I ; 98i 0 i I (E= I * R) ' 1 f 0 1ZR-MC @75CD t 1 1751 i1 1i ci 0 c Ic,E EOL Volage 20.051 0 ZR-MC110CD 233i 0 i , (20.4-E) 1--------------------------''11 1 t i i; . 0i i 1t ; i 1 DEVICS-=;2 1 TOTAL mA=I 273 12 1 200 20.0461921 273 i i 1 , t 1 i : . Notification Appliance Circuit Detail'' 1 _ ,.1.. I.,. PROJECT:1WESTFIELD SOUTHCENTER MALL, , : i 1 • . ! .., , Panel: ISARKU& Wire Resistance •16 ; e , • , .I ; Date: i April 3;,2008. :. '; : H. . • : : ' . • 1 ' CURRENT TOTAL=13.6 . 1 , .CIRCUIT•SPEAKER CIRCUIT ...1 ! ' i , . QTY De i 1 - : ti. Deice Type 1 '„,Alarrn CUrrentiuAlarm Total; 1 Wire 8ize I VVii-e Length Voltage at EOL i :ti it Total ' .I ..c:- ..... I CircU c , 70.7V 118 2 .1.81 ., 3.61 1 , 4 'I : ' '' . 1 i 'ITotal Wire Resistance ( R ) ; 2.06 . 0 03 0i . i i . (' WL * 2 )* (Rift) 0 0- 01 1 Total - "-• - Device Load, Amps (I), ,‘- 0.00 0„ - -i 1 1 i.(Total Cct Load) 0 O(1yoltage Drop (E) 0.01 . , . . i, , ' ..... .. 1 ,.,. .( E,= I * R). ..",, : : I 0 1 IEOL;VOltage20 .39 .. e .'' - . ' - . '' ,' .10 ' ' ' . ' 1 . .,, ,.. ,'- ; .:,c;..• .;. -. ;11 :': ' ! ed';: 1 . ' (;2 0:4 - E) • ,H 0 ; 0 0 i i 0 i 1 0 i 1 1 ' . . i L i . . . ' , c 20.3925696! ..' TOTAL m A.,! t 3.6 12 200 3.6 , i• ; i • DEVICES=i2 TAGE DROP CALCULATION • ' . . . • . • •.• . . . • .1•;;j! ; ; . I ' Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved DRAWN ;BY: 1.,ANOERSON DESIGNED BY: R,.YEZZANI BACKROUND.;PLAN PROVIDED BY: • 08;NUMBER• , • ; • SHEET -o t SARKU SARKU FACP ADD ONS SIEMAENS PAD -3 Signal Extender Panel Battery Load Calculations Current Load: Standby: Alarm: Current Load: Standby: Alarm: ; ; , , Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 AD2-P 2 0.0635 0.0635 0.064 0.128 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R HTRI-D ._ ;4. 2 �009600 0.0096 0.021 0.042 SET -MC @15CD SET -MC @30CD SET -MC @75CD 0.064 0:001600 0.0035 1 0.098 0.098 i 1 0.175 0.175 SET411C @110CD 24-nia. 618cp ZR -MC @30CD ... „ . HCP 0.233 .. . . 0.064 . ' , 0.098 0.0731 Amps 0.17 Amps 0.0015 ` e 0.03 Amps 0.303 Amps Standby COI -rent Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours !, I Alarm Current Load: , 0.17 Amps For 5 Minutes= 0.014 Amp -hours -1! Alarm Current Load: 0.303 Amps For 5 Minutes= 0.025 Amp -hours 25% Derating= 2.211 Amp -hours 25% Derating= 0.932 Amp -hours : • ;; ' fl Total System Current Load: 2.211 Amp -hours ;11 . Total System Current Load: 0.932 Amp -hours U Battery Pi to be Used: 12VDC Amp -hours 7AH . • t ; -i. :; • Battery Pair to be Used: 12VDC Amp -hours 7AH • g xxxx RECOMMENDED MINIMUM BATTERY SIZE = 7,00 AmperexHours ATTERY SIZING CALCULATION '`4••11 , Date: !April 3; 2008 • • Notification Appliance Circuit Detail PROJECT: 1WESTFIELD SOUTHCENTER MALL Panel: iSARKU !Wire Resistance 3 24 CURRENT TOTAL= 273 i , 1 CIRCUIT:iS1 ; QTY I Device Type Alarm Currents,' Alarm Total ; VVire Size 1 VVire Length ! Voltage at EOL ' Circuit Total 1 , , I i 64 CO , 1 1 ; i Total Wire Resistance ( R ) 1 0 1SET-MC ©15CD ' 1 4 1.301 ;1 I , • 1.4') 00 0\ 3 IST AVE. SO., SEATTLE, WASHINGTON •1 FAX (206) 628-4990 TEL. (206) 622-6545 0 ET) 5 uJ Lid LU uJ c ,• 14 •=•.;';„:" CC ,.„ ' •,... 0 SET -MC ©110CD 1 0 1 : )SET -MC ©75CD 4 iZR-MC ©15CD 1 t " ; _2331 175 98! 1 _ 0 175i s 1 I , - 4 , 1 , t 1 .; ? 1 ;Total Device Load, Amps (1) I i , 1 (Total Cct Load) .. , t 0c:2375 if!' . t 1 SET -MC @30CD i 98i i t ; , t i 1 { ( WL * 2 )* (R/ft) 641 Oi ; 1 ; I -t ;Voltage Drop ( E ) ., ;;;;; 0 ZR-MCi@30CD I ; 98i 0 i I (E= I * R) ' 1 f 0 1ZR-MC @75CD t 1 1751 i1 1i ci 0 c Ic,E EOL Volage 20.051 0 ZR-MC110CD 233i 0 i , (20.4-E) 1--------------------------''11 1 t i i; . 0i i 1t ; i 1 DEVICS-=;2 1 TOTAL mA=I 273 12 1 200 20.0461921 273 i i 1 , t 1 i : . Notification Appliance Circuit Detail'' 1 _ ,.1.. I.,. PROJECT:1WESTFIELD SOUTHCENTER MALL, , : i 1 • . ! .., , Panel: ISARKU& Wire Resistance •16 ; e , • , .I ; Date: i April 3;,2008. :. '; : H. . • : : ' . • 1 ' CURRENT TOTAL=13.6 . 1 , .CIRCUIT•SPEAKER CIRCUIT ...1 ! ' i , . QTY De i 1 - : ti. Deice Type 1 '„,Alarrn CUrrentiuAlarm Total; 1 Wire 8ize I VVii-e Length Voltage at EOL i :ti it Total ' .I ..c:- ..... I CircU c , 70.7V 118 2 .1.81 ., 3.61 1 , 4 'I : ' '' . 1 i 'ITotal Wire Resistance ( R ) ; 2.06 . 0 03 0i . i i . (' WL * 2 )* (Rift) 0 0- 01 1 Total - "-• - Device Load, Amps (I), ,‘- 0.00 0„ - -i 1 1 i.(Total Cct Load) 0 O(1yoltage Drop (E) 0.01 . , . . i, , ' ..... .. 1 ,.,. .( E,= I * R). ..",, : : I 0 1 IEOL;VOltage20 .39 .. e .'' - . ' - . '' ,' .10 ' ' ' . ' 1 . .,, ,.. ,'- ; .:,c;..• .;. -. ;11 :': ' ! ed';: 1 . ' (;2 0:4 - E) • ,H 0 ; 0 0 i i 0 i 1 0 i 1 1 ' . . i L i . . . ' , c 20.3925696! ..' TOTAL m A.,! t 3.6 12 200 3.6 , i• ; i • DEVICES=i2 TAGE DROP CALCULATION • ' . . . • . • •.• . . . • .1•;;j! ; ; . I ' Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved DRAWN ;BY: 1.,ANOERSON DESIGNED BY: R,.YEZZANI BACKROUND.;PLAN PROVIDED BY: • 08;NUMBER• , • ; • SHEET -o t 07077.,, ;41 A El; Without Comments As Noted in Red Per The Attached Letter INSTALL FRP ON 5/8" GYP. BD. FASTENED TO METAL STUD FROM TOP OF WALK—IN COOLER TO U/S OF FINISHED CEILING (WP 1-iese plans have been reviewed by The Tukwila Fire BUreau for conformance with current City ..andards. Acceptance is subject to errors and • .iiissions which do not author12.e ‘tiolatinnof adopted, .•,,ndardsandordinance's, The responsibillty l'or the •--..!equacy of desion rests totally with the drezIgner, ;Additions, deletions or revisions to the.;;..-; drawings after • tms date will mid this .icceptance and wiii require iesubrnftta of-feYised drawings for subsequent approvc<1. • • • Final acceptanceis subject to field test and inspection by . The.TUkwila Fire Prevention Bureau. Date' ti . -"I Bv:/-f 1 ( TUKWILA DEi-siARTAL'..31 Piea5zaH 206-575-44W F]rid give, Five, No. and exact addrzss for shut- down or restoration approval, '• / \i \ // 1,P4A _ \ OPEN CEILING • • • TO STRUCTURE ABOVE • ADD D.V.R. CABINET & CABLING 12" AWAY FROM T—BAR CEILING DETAIL REPLACE HVAC RETURN AIR DIFFUSER EXISTING SOFFIT Si SERVICE/ CLEAN EXISTING EXHAUST DUCT SERVICE HVAC, MUA, EXHAUST FANS & ROOFTOP PROTECTION EXISTING FIRE ALARM TO REMAIN REPLACE STOREFRONT SIGNS (SHOP DRAWING TO BE SUBMITTED TO LANDLORD FOR APPROVAL BY MANUFACTURER SEPARATELY) REPLACE REPLACE EXIT LIGHT EMERGENCY LIGHT I I • • , PREP. 11 HATCHED AREA INDICATED 77(P12'-0" A.F.F. RAISED UP CEILING DETAIL 06 ///// ////7 WP2 —37 . REPAIR & RE—PAINT T—BAR GRID, I • I REPLACE VINYL CLAD CEILING TILES • J -(1)- 4 *1 ... -4E13 I I I I + SERVICE I L EFLECTED C El LI \ G PLA\ EXISTING JAPANESE SCREEN AROUND EXISTING EXHAUST HOOD SHOWN DOTTED (SEE ELEVATION) EXISTING H000 ENCLOSURE • TO REMAIN SERVICE/ CLEAN EXISTING EXHAUST DUCT REPLACE FLUORESCENT LED LIGHT FIXTURE, RECESSED TROFFER 2'x4' REPLACE HVAC SUPPLY AIR DIFFUSER (DIFFUSER TO BE HINGED TYPE, TO FACILITATE FILTER) EXISTING UST E-3-0—ArD E INSERT ONLY) RE—PAINT EXISTING DRYWALL CEILING IN WHITE ADD DigLIA (SErtLEVATION) U DISPLAY REPLACE BLADE SIGN REPLACE RECESS DOWN LIGHT (TYPICAL) SCALE: 1/4" = 1'-0" Design per NFPA 13 — Ordinary Hazard Group 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions • 1 — Add Globe GL5680 Quick Response 200° Dry Pendent % x % EXISTING SOFFIT . .. . &:•- FlexHead Sprinkler Drop . • . • • . . . • • '. • . • .. Cofrugated stainless steel hose with stairiless steel bral • available In 2, 3,4',5' & 6' legnths . • kulli-PortBrackei • Adjustable Hub R ---.1mmumemmirjommommimmip, FLthyBEAD •• • • • • .• • F:loxheatbmne.. rola, cOiling Unit T -Bar Ceiling Installation . • • Model #2024,036,2048,06O,2072 0 I a, ;047,0 • RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C—CLAMP. • WITH SET SCREW • 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL ..113 IST/TRUSS • HANGER DETAIL. NTS 8ARKU JAPAN SPACED FC -3 LEVEL: 02 OF 3 SO. FT. 816 • 0 • 4Lo1-( v‘to • * o • • • o' • • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Project • Sarku japan • WESTFIELD SOUTHCENTER (SPACE# FC -3)• 240Vi3Var SOUTH CENTER PARKWAY *TUKWILA, WA 98188-2888 DATE: j aid . DRAWN: d / I SCALE: .1.• • • ••• 1r4 ID c\A • Fa -3 0- 2019 k, TV. ILA FIRE .Z71 7'e. eza; Wthout Comments M Noted in Red Per The Attached Letter 1 uttWILA FIRE DEPARTMENt'it Please call: 575-440Z _end give this job Jo. _ ,rld exact address for shut+ ,n or restoration approval: = i nese plans have rovic.wed by The Tukwila Fire Prevention Bureau ,'pr cci:iorrlla.rice with current city standards. Acc,ew:: r1t;t: i;.. to errors and omissions whio11 i:)cJ viulstion:s U1 adopted standards and roL perlSibitit jr for the adequacy or d€ Sigh r; ::.'; . 1(?L9++v 'v:rliil tt'i(•; designer. Additions, c ef:.:i!)ris or I;:vi ;ipn`:_ h; the.e. drawings ratter this date will void Lill, ac copt;_;nc€ unci will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire, Prevention Bureau., AT Date: L//)1 ° K By: A-141 3// i ut\VVIL.A FIRE DEPARTMENL Please call: 575-4407 and give this job No. d3S — /I `/ and exact address for shut.' Town or restoration approval: AlanCE. Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic test approval. WALK• I /•,LK I I COOLER BELOW WALK-IN FREEZER BELOW CONSTRUCTION NOTES: a GENERAL NOTES: ) 1) PIPE: THREADED: STEEL, SCH 40, BLACK, IMPORT. GROOVED: STEEL, SCH 10, BLACK, IMPORT. 2) FITTINGS: GROOVED: STAR STANDARD - ORANGE PAINT FINISH THREADED: STAR D.I. 3) GROOVED COUPLINGS: STAR RIGID C-4 UNLESS MARKED WITH AN "F", WHICH ARE TO BE STAR FLEXIBLE C-3 LW - ORANGE PAINT FINISH 4) HANGER MATERIAL: ALL HANGER MATERIAL IS TO BE FINISHED BLACK OR STANDARD LIST OF ELEVATIONS:) EXISTING SPRINKLER PIPE 4. @ 16'-0" FINISHED FLOOR TO BOD = FINISHED FLOOR TO BOB = ACT CEILING HEIGHT = I0'-0" GWB CEILING HEIGHT = 12'-6" SYMBOL LEGEND:) = EXISTING AUTOMATIC UPRIGHT SPRINKLER.` = EXISTING AUTOMATIC PENDANT SPRINKLER • = NEW RECESSED PENDANT ON DROP • = NEW CONCEALED PENDANT ON DROP • = NEW DRY PENDANT s----5 = EXISTING SPRINKLER PIPE — NEW SPRINKLER PIPING 1/4" MIN SYSTEMS ARE DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF N.F.P.A. 13-2007 ED., THE CONTRACT DOCUMENTS, AND THE CITY OF TU KWI LA. CRITERIA: OCCUPANCY: LIGHT HAZARD, AND ORDINARY HAZARD GROUP I. LIGHT HAZARD SPRINKLER SPACING: 225ft2 MAX. ORDINARY HAZARD GROUP I SPRINKLER SPACING: 130 ft2 MAX: 2) COSCO'S POINT OF CONNECTION IS AT EXISTING SYSTEM A5 SHOWN. 3) ALL PAINTING OR PREP OF FIRE SPRINKLER PIPING ( IF REQ.. ) TO BE DONE BY OTHER. 4) ALL WIRING OF SYSTEM DEVICES IS BY OTHER. 5) OWNER IS RESPONSIBLE TO ASSURE THAT THE STRUCTURE, AS IT IS SHOWN ON THE CONTRACT DRAWINGS, CAN ADEQUATELY SUPPORT THE FIRE SPRINKLER PIPING. NO AUXILIARY DEVICES OR ATTACHMENTS SHALL BE PROVIDED BY COSCO TO SUPPLEMENT THE STRUCTURE. G) OWNER IS RESPONSIBLE TO PROVIDE ADEQUATE HEAT TO MAINTAIN 40° F. MINIMUM AT ALL TIMES. 7) OWNER IS RESPONSIBLE TO ARRANGE FOR THE PERIODIC INSPECTION, TESTING, AND MAINTENANCE OF THESE FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF N.F.P.A. 25-2002 ED., BY QUALIFIED PERSONNEL COMMENCING AFTER WARRANTY PERIOD HAS EXPIRED. THE FIRM THAT DESIGNED AND INSTALLED THE SYSTEM(S) IS BEST QUALIFIED TO PROVIDE THE ONGOING LONG TERM TESTING, MAINTENANCE, AND SERVICING. 8) ANY RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE OR CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIED OR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO FIRE PROTECTION. HILTI KWIK BOLT 3 ANCHOR ICC REPORT #ESR -1385 MIN. OF 3,000 PSI CONCRETE MIN. 3 I/4" CONCRETE OVER MAX. 3' METAL DECK 3/8' ANCHOR W/20# TORQUE: TENSION=395#,SHEAR=750#• 1/2" ANCHOR W/40# TORQUE: TENSION=440#,SHEAR=750#• •fH WI LOADS HAVE®! RHI.C® BY DM FOR THEM TIRI THREADS ROD COUPLING THREADED ROD PIPE SIZE ROD DIA. BOLT LGTH IMBED DEPTH HILTI FIG. LH OR TOLCO FIG. 200 HANGER RING UL 04/2007 I COSCO STANDARD HANGER I 13 MDL EXISTING SSU 1" ' SEE PLAN FOR LENGTH REMOVE EXISTING z 1"SPRIG INSTALL . w NEW 1"x0-4 NIPPLE LLJ W "' O LL EXISTING BRANCH LINE ADJUSTABLE DROP NIPPLE AT GYP BOARD CEILINGS lx 1/2 RC AT AC TILE CEILINGS CEILING EXISTING SSU SEE PLAN FOR LENGTH PREP i REMOVE EXISTING 1" SPRIG INSTALL NEW 1"x0-4 NIPPLE SEE PLAN FOR LENGTH EXISTING BRANCH LINE ADJUSTABLE DROP NIPPLE AT GYP BOARD CEILINGS 1x 1/2 RC AT AC TILE CEILINGS CEILING A TYPICAL ARMOVER TO NEW SPRINKLER HEAD N.T.S. y211 N JOB SITE ''r` t`u x'' 5.152nd aE1'ICE baniel McLu n 391-076676 SARKU JAPAN SCALE: Y2" = 11-O" Yin Vii';, .:: "$ 1s6cr, 2008 SPRINKLER HEAD LEGEND : SYMBOL S/N ORIFICE Reliable Model F1 FR Recessed Pendant Reliable Model FI FR Concealed Pendant Reliable Model F3QR Standard Dry Pendart (A =18) 1/2' 1/2' 1/2' NPT 1/2' 1/2' 1/2' K•FACT. 5.6 5.6 5.6 HEAD FINISH Chrome Chrome Chrome PLATE FINISH Chrome Chrome Chrome TEMP. 155° 155° 200° QUAN. 6 3 2 • 0 0 00o0. • oO 00 00• '000000• • 0®®• APPROVALS BY: TOTAL SPRINKLERS THIS SHEET 11 Icosco Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS WASHINGTON OFFICE 10910 117TH Place N.E. License No: Kirkland, Washington 98033 COSCOFP1 IONM call (425) 827-9654 • fax (425) 827-7474 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE • ANCHORAGE www.coscorire.com PROJECT: Sarku Japan Southcenter Mall Foodcourt a4640 6)&Southcenter Mall Sucre-- Fc ---5 Tukwila, Wa. 98188 DATE : April 2008 SCALE : As Noted DRAWN BY : Justin Johnson CONTRACT WITH: Woodburn Construction P.O. Box 129 Woodbum, Or. 97071 (757) 291-4743 DRAWING ITU Piping Plan: Sarku Japan (Space # FC -3 TI) SHEET NO. 1of1 `�1 2600 SOUTHCENTER MALL FC -3 FOOD COURT ASSOCIATED PERMITS 19-F-044 08-F-112 08-F-097 19-S-037 19-S-035 08-S-114 19-H-049 SITE LOCATION ,21,00 Site Address ,�I l \/,:[..�( it{X eN �L1, r:C'� Suite Numbei Floor: Tenant Name: iL� a t_t tic\(c) (UJ\ New Tenant? El- Yes j - No R.t�\ Property Owner's Name: VN.i 6(3, r"".,( C YeX 43 ` c - C • Mailing Address: C3C) `jtT O (\ZVW13eXC3 l.A q2b l3 City State Zip CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.:0 D 1M \ CONTACT PERSON -if there are questions about the submittal. Name( \ /ck C.Pf1 KC I% IA'01/1_ Day Telephone: kao.)4,15-5b4fp Company Name: uctic \Qi& ,%ity i �L t 3,,-\br ,`J Mailing Address:VA**i) e`^ AV'P , 6 J fyy-t x-1111 A aqA' ). City State Zip Fax Number: ntrBusiness City number: ." ®CAn2q3S+ NICET III number: Business License number: J �-1 E-mail Address: Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ t 2-Crb Scope of Work (please provide detailed information): Cmmcwo\ibc\ - ack i (�) PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. AICA BUILDING OW R OR AUTHORIZED AGENT: Ff-71 ?B' Signature: ` k C TUKWILA eiR Daterl `ct ry t1"t Print NamS,t 3 (rei Voi cvc s u 1A- Day Telephone: Pa Q) OS- i Plan Pennit App.doc 8122/14 TFD FP Form 8 410044 4tt CITY OF TUICWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted fur plan review. **PLEASE PRINT** SITE LOCA ION` _l King Co. Assessor's Tax No.: Site Address: JCI,tha T*k ' rika ! Suite Number: Floor. Tenant Name: G rkt) Japri New Tenant? ❑_ Yes ❑ - No Property Owner's Name: lA -G r y Mailing Address: Scv-fitiCerikY Mai 1 • Tu bu I la / 1.0A - City State Tap CONTACT PERSON -if there are questions about the submittal. Name:3.'ed‘COL.0) n5On Day Tom: 142.G •'-[ S '761 (09 Company Name: effbviY1 Th'hctiYi, 1 G Mailing Address: ri s a // i )1 C Y?i � 9S'd 32. C�1YYI cgy State Etp E-mail Address:3.e.icaecrotAm-C-p. Fax Number: C011ifiCiDeS City of Tukwila NICET III number 97941 /pql • �C� B mss License number: 81 2.5 • o07474,9/Z Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 250 :--- Scope of Work (please provide detailed information): 0 5f "Irl /4 r- h PERMIT APPLICATION NOTES Vale of Construction — b all cases, a value of constitution amormt should be erred by the applicant- This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid uolessd a work on the site authorized by such permit is commenced within 180 days alter its roe, ix ffthe work authorized =the site by such permit' is suspended or abandoned fora period of 180 {lays atter the time the work is commenced. The Fire Marshal is authorized to grant, in .. writing, one or more extensions of time for periods not more than ISO days each. The extension shall be tequested in writing• and justifiable cause demonstrated, I HEREBY CERTIFY THAT I HAVE READ 4ND EXAMINED MRS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZ JJ AGENT: Signature - Print Naine ignature:I ntName 7eS5ICa. braes -7 Plan Permit App_doc 822/14 'Daft: 2•(o•11 ictiyirdephow • •Xdoq `NFDFPFain8- 44.ttiLW444 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: W6s1F i6c.{a 1 2600 SOOTC i (L. F1t4u, Suite Number: FC Floor: 2 Tenant Name: Property Owner's Name: F Mailing Address: 2600 r6 -e, 8 '0 - CONTACT PERSON -if there are questions about the submittal. Name: 0 PC 4-t n V/19-51-6 l f Cj IC -i Company Name: K T Pao l> New Tenant? ❑ - Yes ®- No City State Zip Day Telephone: 206 - - a 5110 Mailing Address: G100 i 2V, iWt _ S LS (,✓ A g g 10 g City State Zip E-mail Address: C N T*1-� . ® 'P -T Ka01% CONI Fax Number: 206 - 464, 26o" Contractor's City of Tukwila U S — 05')S � �S� NICET III number: Business License number: Total number of new/relocated devices or sprinkler heads: (% Valuation of Project (contractor's bid price): $ 4• I oo Scope of Work (please provide detailed information): RC- SCP -E of 2.. (Two) h44.) 1JkL P�� � ; o►J PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in )J writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WAI-LIJGTON, AND I AM AUTHORIZED TO APPLY r� FOR THIS PERMIT. MAR 1:."! 2719 Signature: TUKWILA FIRE Date: i'/ 4 (1 1) Print Name: 2 rk� [ 1111 LDaay Telephone: 206- 4 2,6 - 0 3 1 a BUILDING OWNER OR AUTHORIZED AGENT: Plan Permit App.doc 8/22/14 TFD FP Form 8 LA) FiLE FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Sarku Japan 2600 Southcenter Mall # FC -3 Permit No.: 08-S-114 Date: April 8, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. taxa / Fire & Security R-102 RESTAURANT SYSTEM NOZZLE COVERAGE SUMMARY SHEET F I81.IARESUL:) Appliance Nozzle Type Flow Points Width (In) Max. Side Length • (In) Max. Side Multiple Nozzle wo/Drip Board Area Sq. In. Multiple Nozzle w/Drip Board Area Sq. In. Min. Nozzle Ht. (in) Max. Nozzle Ht. (in) Fryers without drip boards 230 2 14 15 — — 27 47 Split or No Split Vat 245 2 14 15 — — 20 27 Fryers without drip boards • 290 2 19.5 19 — — 13 4 • 16 Non -Split Vat (ONLY) 3N 3 19.5 19 — — 21 , 34 3N 3 18 18 — — 25 35 . Fryers with drip boards 230 2 14 21 210 294 27 47 Split or No Split Vat' 245 2 14 21 210 294 20 27 Fryers with drip boards' ^ 290 2 19.5 25 3/8 370.5 495 13 . 16 Non -Split Vat (ONLY) 3N 3 19.5 25 3/8 370.5 495 21 34 3N 3 18 27 3/4 324 497 25 35 Tilt Skillet/Braising Pan' Coverage limitation are based on fryer sizes including the drip boards. Exception Tilt Skillets and Braising may exceed the maximum of 6 sq. ft. Range 1N 1 12 32 — — 30 40 Without back shelf 1F 1 12 28 — — 30 50 With back shelf 1F 1 12 28 — — 40 48 245 2 24 28 — — 40 50 Without back shelf 260 2 24 32 — — 30 40 With back shelf 260 2 12 32 — — 30 40 2 xC90 4 36 28 — — 15 20 Griddle : . 1N/1NSS 1 36 30 — — 35 40 290 2 30 24 — — 30 50 60 2 48 30 — — 30 50 290 2 48 30 — 20 .30 2120 2 48 30 — — 10 20 Chain Broiler' (Overhead Protection) 2 x 1W 2 34 30 • — — 10 26 Chain Broiler (Horizontal Protection) 2 x 1N 2 31 43 — — Front edge; above the chain 1 in. - 3 In. Char Broiler Gas -Radiant 1N/1NSS 1 24 36 — — 15 t 40 Electric 1N/1NSS 1 20 34 — — 20 50 Lava -Rock 1N/1NSS 1 13 24 — — 18 35 Natural Charcoal ' 1N/1NSS 1 12 24 — — 18 40 Lava -Rock or Natural Charcoal ' 3N 3 24 30 — — 14 40 Wood Fueled' 3N 3 24 30 — — 14 40 Upright Broiler 2 x 1/2N 1 30 32.5 Front edge; Salamander Broiler 2 x 1/2N 1 30 32.5 — above the grate 1N 1 16 29 — — — — 1 N nozzle location to be on the vertical edge 6 to 12 in. in front and 0 to 12 in. above the top of broiler Internal Chamber 1N 1 16 I 29 — — 6-12 In. above either end Wok 3.75 to 8 inches deep 260 2 14 in. to 30 in. diameter — 35 45 3 to 6 inches deep 1N/1NSS 1 11 in. to 24 in. diameter — 30 40 ,' For multiple nozzle protection of single fryers, see detailed information on pages 4-10 to 4-11 of manual. ' See Figure 1 for nozzle Location. ' Minimum chain broiler exhaust opening – 12 in. x 12 in. (31 cm x 31 cm), and not less than -60% of internal broiler size. 4 In. (102 mm) maximum fuel depth. u In. (15 cm) maximum fuel depth. FILE COPY Fire & Security R-102 RESTAURANT SYSTEM NOZZLE COVERAGE SUMMARY SHEET ANSULA Plenum 'Single Nozzle Type Flow Points Width (In) Max. Side Length (In) Max. Side Nozzle Placement (See Manual for More Detail Min. Height Max. Height Hb nzontal=Protection Bank 1N 1 46-- 120 0 in. - 6: in. from end of plenum 2 4 Perpendicular Protection Single Bank 1 W/1100 1 48 48 See Manual for more detail 1 20 Horizontal Protection V -Bank 2 x 1N 2 48 120 0 in. - 6 in. from end of plenum 2 4 Horizontal Protection V -Bank 1W/1100 1 48 72 0 in. - 6 In. from end of plenum 1/3 the height , of filter Perpendicular Protection V -Bank 1W/1100 1 48 48 See Manual for more detail 1 I 20 Duct Nozzle Type Flow Points Perimeter (In) Diameter (In) Nozzle Placement (See Manual for More Detail) Duct Length (In) Single Nozzle 1 flow nozzle 1100 1 50 16 See Manual for more detail Unlimited Single: Nozzle 2.6w:nozzle. 2W 2 100 31 7/8 Sea Manual for more detail Unlimited Multiple Nozzle 2W +1100 3 135 48 See Manual for more detail Unlimited Multiple 2W Nozzle 2W — >135 >135 See Manual for more detail Unlimited R-102 OVERLAPPING PROTECTION The 245 nozzle, Part No. 419340, is the only approved nozzle for overlapping (zone) protection. Appliance Type Fryer Griddle Range Wok, Maximum Wok, Minimum Braising Panfrilt Skillet' Lava Rock Char -Broiler Charcoal Broiler Mesquite Wood Broiler Gas Radiant Char -Broiler Electric Char -Broiler ' See Figure 1 for nozzle location. Maximum Cooking Hazard 34 in. (864 mm) Deep x 5.8 sq. ft. (.54 sq. m) 30 in. (762 mm) Deep x Unlimited Length 28 in. (711 mm) Deep x Unlimited Length 30 in. (762 mm) Diameter x 8 in. (203 mm) Deep 11 in. (279 mm) Diameter x 3 in. (76 mm) Deep 34 in. (864 mm) Deep x Unlimited Length 32 in. (813 mm) Deep x Unlimited Length 32 in. (813 mm) Deep x Unlimited Length (4 in. (102 mm) Maximum Fuel Depth) 32 in. (813 mm) Deep x Unlimited Length (12 in. (305 mm) Maximum Fuel Depth) 36 in. (914 mm) Deep x Unlimited Length 34 in. (864 mm) Deep x Unlimited Length TYCO SAFETY PRODUCTS, ONE STANTON STREET. MARINE I IL, WI 54143.2542 COVER MUST NOT INTERFERE WITH EDGE OF DISCHARGE PATTERN II 0-6 IN. (0-15 cm) II I ! r 1 1 ZONE twww%www%N►www%. 1iI ZONE CENTER LINE 40-45 IN. (1-1.1 m) 006921 FIGURE) 715-735-7411 Form No. F-2005010 02005 Ansul Incorporated Litho In U.S.A.. SECTION IV — SYSTEM DESIGN ► UL EX. 3470 ULC CEx747 Page 4-34 7-1-98 REV.4 ANK AND CARTRIDGE REQUIREMENTS Once the hazard analysis le completed and the total nozzle flow numbers are established, tho quantity and size of agent tanks and cartridges needed to supply the nozzles with the proper volumes of agent nt the proper flow rates can be determined, For cartridges used in the regulated release mechanism, flow capacities, tank quantities and sizes, and regulated release cartridge options are given tri the table below. Total Quantity and Regulated Release Flow Size of Cartridge Options Numbers• Tgnk(s) Nitrogen Carbon Dioxide 1 — 5 (1) 1,5 Gallon LT -20-R (7032) 101-10 (15850) 6 — 11 (1) 3.0 Gallon LT -30-R (5373) 101-20 (17492) 11 — 15 (1) 1.5 Gallon Double (73022) 101-30 (15851) (1) 3.0 Gallon 16 — 22 (2) 3.0 Gallon Double (73022) 101-30 (15851)\lk *When one or more regulated actuators are used, the following tank and cartridge combinations apply for each regulated actuator: Regulated Actuator Regulated Actuator Tank(s) Cartridge (1) 1.5 Galion (1) 3.0 Gallon (1) 1.5 Gallon and (1) 3.0 Gallon ► (2) 3.0 Gallon LT -20-R or 101-10 LT -30-R or 101-20 LT -A-101-30 or 101=30" LT -A-101-30 or 101-30" —'or exoepllone to maximum How numbers, see Distribution PlpIng Requirements Ior 1,S gal• 1 and 3.0 gallon systems In Ihla secllon. For higher total flow numbers (23 to 110), multiple cartridges and regulated actuators are required as shown In the System Selection Guide in Section IX — Appendix. ACTUATION GAS LINE WITH AN LT -20-R, LT -30-R, 101.10 OR 101.20 CARTRIDGE MAXIMUM LENGTH OF 20 FT, (0 m), MAXIMUM NO. OF FITTINGS 0 "ANSUL AUTOMAN" REGULATED RELEASE ASSEMBLY • ACTUATION AND EXPELLANT GAS LINE REQUIREMENTS Thle section contains the guidelines for installing the actuation and expellant gas lines between the regulated release mechanism reg- ulator, each regulated a.otitator regulator, and each agent tank. These limitations should be considered when selecting the com- ponent mounting locations. r Actuation Gas Line — 6 to 6* Tanks Maximum ► • 8 Tank maximum reflects the utilization o13 tank regulated actuators. 1. Use only 1/4 In. Schedule 40 black Iron, hot -dipped galva- nized, chrome -plated, or stainless steel pipe and fittings. 2. The actuation gas line piping is installed from the regulated release mechanism to each regulated actuator connected within the system. The total length of the actuation gas line from the regulated release assembly to the regulated actuator assembly(les) must not exceed 20 ft. (6 m) when using an LT -20-R (Part No. 7032), an LT -30-H nitrogen cartridge (Part No. 5373), or a 101-10 (Part.No" 15850) or a 101-20 (Part No. ► 17492) carbon dioxide cartridge. See Figure 73. REGULATED ACTUATOR ASSEMBLY EXPELLANT OAS LINES NOT INCLUDED IN ACTUATION GAS LINE LENGTH TOTALS FIGURE 73 003775 • \� \ 2 0 0 0cp 0. 3 0 \ C waaln of papauuoa ivays s s Otr ainpayos Naaiq si acid Iv s :31ON paool aq }snw alzzou wnuald s II i II I I iI 36" X 24" GAS RANGE 1 *�1 , . - � ]o\ ��\ 2 e 3l�fW 2131N3DH1f1O NVdV f1H21VS -rind 1VflN W W „OS -017 „OS -017 \ t NO -11V0 E \ k ----- S>11\111 3Sf13.09E -D 0 M§_ }\ \m 0Z a x/ §�2$ o > o /\9 \ ob /2k = ) 11 o Iona ..Z pm I. \ /_ 0 6 111 • 4. a a • D c o o C211' CT 7 0 a 0 0 5- 33 7 CD .< c o cD -a 3 c cn WA co 24" X 24" GAS GRIDDLE • • • • A c z 0 r- 2! +0 0) 0 c ...-------- Iona z P(0 i• 62 -75 6 M01.1 ivnio PAH) 2 1. 2008 Tukwila Fire • • * 0 • 00 • 2 A) > ,. .... - 5 V) > -o - • • <> • • • • • • • A c z 0 r- 2! +0 0) 0 c ...-------- Iona z P(0 i• 62 -75 6 M01.1 ivnio PAH) 2 1. 2008 Tukwila Fire ACCEPTED ❑ Without Comments As Noted In Red Per The Attached Letter nese plans have been reviewed by The Tukwila Fire Prevention Bureau for coriforrnance with current city stan.dards. Acceptance is ?uhfect to errors and omissions which do not authorize, violations of adopted star aaros and oroinances. The r e.ponsibOy for the r' adequacy of design rests totaffu 4,11 s toe designer. Additions, del ;'ions or , ti.hs;on. ,_ ineee drawings atter this date will void thiei.ac ;eptan ce 9 -id will require a resubmittal of revised ciravtiings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire. Prevention Bureau. Date: c/ -1- O g By: 11l or _t —S11vh+ +r;r 4i ctiso ihotv44 eler;+r;c l .511A—of-F. — 5 \vhf- +r;p iv 4 #rM* oc wrkic-c tie q;r et .1 e tutus4 S1 U.L. i't s 1-vr.„ 1 s A-i;,.i po" -fuer-) re v:1 -c, 4. I UKWILA FIRE DEPARTM .Lfl Please call: 575.4407 and give this job No. OR- and R- and exact address for shut. sown or restoration approval; • 0 §C\ §§j o .Lu §kutLk 2§�§ cd&/ =0 to0 0 0 _ k • #/ O • Ef)f ±kkIt) $ ; b£ ${R° iq al §)f E£ Ef• «2t 0. {t& ACCFT 0 Without Comments As Noted in Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance vvith current City standards. Acceptance is subject to errors and ;missions which do not authorize vio ations of adopted standards and ordinances, The responsibility for the adequacy of design rests totally with the designer. Additions, deletions: or levisions to these drawings after this date will void thL; a -c pptance and wiii require a resubmittal of revised drawings for subsequent approval. Final acceptance is, suoject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: -141 By: 1 I TUKWILA FIRE DEPARTMENT F Please' call 2S6-575-4407 and �d give ti -L; Fim Para No. 19 -1� and exE c:;iddress for shut- down hutdown or restoration approval. Feb 2619 03:02p Crown Fire Protection I FAX TRANSMITTAL 4254818695 p.1 Fax No. CROWN FIRE PROTECTION, INC. MEM 2.26.19 Fire Prevention Bureau Tukwila Fire Department / Al Demo Permit \unrbur of Parc" (InclutlinLv, Cup cr ) 1 1206.575.4439 0 Urgent EB For Review 0 Please Comment ❑ Please Reply F ronr Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comment We need a demo permit for 2600 Southcenter Mall FC03 in the Sarku Japan space. The General Contzactor needs us to demo 4 sprinkler heads out of a soffit they are moving. The building permit number is D18-0384. Tl>anks- oMr AiMMT► PIwe PROTECTION BPRIWMAR SYSTEMS John Thorns aeMsrlina 9794-1001-C43 Level 3 Crown Firs Protection, Inc. I. w. uiiutliLA FIRE l E?ARa 1 lv1C:.:laT call 206-575-4407 and ova this Fire Permit No. /9-3-03 - and exact address for shut- down hydown or restoration approval. ■ ■ ■ P.O BOX 12ht3 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8695 13 Without Comments p As Noted in Red p Per The Attached Letter These plans have been reviewed by The. Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance i, subject to errors and omissions which do not authorize violatio! Is of adopted tandards and ordinances. The responsihliicy for the idequacy of design, ; a.F.:, totally with the designer, Additions, deletion s v6slorys to these drawings after this date will void um:- and will require a resubmittal of cnwinos for subsequent approval. Final acceptance: ! suojeci to field test and Inspection by The Tukwila Fire Preventio(? Bureau, Date 3-1)- "/ B. lk ftUic.;/ IA FIRE DEPARTMENT 2:C5-575-4407 and CJ th31� ere P rni't o. and exact address for shut- down hutdown or restoration approval. FIRE ALA u M S s` STEM SHINS 1==° DITION N SHEET \ U V 3E. SHEET TITLE FA -01 SYSTEV \FO' V ATI O FA -02 TYPICAL WI G A\3 V OU\TI\G DETAILS FA -03 SYSTE V CALC U LATI O \ S A\D SI\GLE LI\E 3IAGAV FA -04 FRE ALAN SYSTEV PLA\ SHEET INDEX ADD 3 NEW CEILING MOUNT SPEAKERSTROBES, 1 NEW WALL MOUNT STROBE & 1 NEW MONITOR MODULE ONTO AN EXISTING FIRE ALARM SYSTEM SCOPE OF WORK WRE SCH RULE A\D CO\ D U IT FILL CHAT SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END EXPIRES 09/01/2020 FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NEPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 3 E E E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP FIRE ALARM STROBE (NEW) ZR -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2 EXTN CEILING HT -D DUAL INPUT INTERFACE MODULE (EXISTING) HTRI-D SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DDT (EXISTINGETECOR) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY (EXISTING) HTRI-R SIEMENS 4S BOX VERIFY IN FIELD TENANT �E J -BOX F.B.O. F.B.O. VERIFY IN FIELD END-OF-LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N /A N/A N/A E EXISTING DEVICE N/A N /A N/A N /A F.B.O. FURNISHED BY OTHERS N/A N /A N/A N /A N /A NOT APPLICABLE N/A N /A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N /A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND SARKU JAPAN 2800 / SPACE# FC -3 ES n..Atal 0 1264 0. 0 w 0) i 1 FC161 U n:. ,..w 0 ktJ 7 0) o y 0 .) a0) c> nr FS 22120 1G NI2 i zsl - 0 121301 a n nitil THAI GO 0 0 0 0 1R:11 JOHNNY ISHai KVS / r -F a n 07:00 0 0 0 21551 41.0j :r 0 122051 0 /Eg.1 1 ° BAYOU GRILL >a v. WIRE DESIGNATION GENERAL NOTES SITE PLAN a PAID FEB 23 2019 TUILA ARE Cie TOR F , 4io co 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS . VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END EXPIRES 09/01/2020 FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NEPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 3 E E E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP FIRE ALARM STROBE (NEW) ZR -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2 EXTN CEILING HT -D DUAL INPUT INTERFACE MODULE (EXISTING) HTRI-D SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DDT (EXISTINGETECOR) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY (EXISTING) HTRI-R SIEMENS 4S BOX VERIFY IN FIELD TENANT �E J -BOX F.B.O. F.B.O. VERIFY IN FIELD END-OF-LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N /A N/A N/A E EXISTING DEVICE N/A N /A N/A N /A F.B.O. FURNISHED BY OTHERS N/A N /A N/A N /A N /A NOT APPLICABLE N/A N /A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N /A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND SARKU JAPAN 2800 / SPACE# FC -3 ES n..Atal 0 1264 0. 0 w 0) i 1 FC161 U n:. ,..w 0 ktJ 7 0) o y 0 .) a0) c> nr FS 22120 1G NI2 i zsl - 0 121301 a n nitil THAI GO 0 0 0 0 1R:11 JOHNNY ISHai KVS / r -F a n 07:00 0 0 0 21551 41.0j :r 0 122051 0 /Eg.1 1 ° BAYOU GRILL >a v. WIRE DESIGNATION GENERAL NOTES SITE PLAN a PAID FEB 23 2019 TUILA ARE Cie TOR F , 4io co 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 0) N 0 2aaaaa Z 0 0 z SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/ 15/ 19 BACKROUND PLAN PROVIDED BY: Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved .OB NUMBER: 3801 1-1; SHEET .0 FA -01 .All 120VAC-6014Z - DEDICATED EMERGENCY THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL FROM EXISTING MAIN FACP C CABLE C' CABLE 0 0EIE1 ORD N C T T T T 0 PAD -3 0 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 uN& 3.6k EOL 0 u 0 1_01 0 0 0 (-) (+) (-) (+) NAC S4 NAC S3 NAC S2 j NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL HARD LID CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE ° o°. o SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) (+) ( ) STROBE SPEAKER (+) (_) 1� U (+) ST ) ROBE (+) ) STROBE SPEAKER (+) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE HFP-11 N / TB1 1000®�©� ® 0 1D NO COM NC TO FAN SHUTDOWN EOLR 470 SWITCH + INPUT LED TSM -1 00 0 TO NEXT ADDRESSABLE DEVICE 0 3 4 00 HTRI-R 0 NO B COM ® NC (9 ^ Q 0 o/2) TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL TO NEXT DEVICE OR END OF LINE TO EXISTING DATA LOOP 0 0 e Lei /MI 2 3 4 5 00 HTRI-D 7 6 e o /2, KITCHEN HOOD MONITOR KITCHEN HOOD MONITOR WIRING DETAIL EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 17 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: o M 0 DESCRIPTION SHOP DRAWINGS DATE 0, Lo N 0 C U ZU LU 10 Z 1_QO) <^ og3E0 1� J� Lji D Cr) wi9 CC CC < cn Q=_ LLO� 0 N (zI SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/15/19 BACKROUND PLAN PROVIDED BY: .,JOB NUMBER: 3801 1 -1 J SHEET FA -02 A B C D E F G H I .1 K FIRE ALARM BOOSTER Project:SARKU JAPAN Panel: EXISTING BPS PAD -3 Date:: February 15, 2019 Module/Device POWER REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 =TOTAL FIRE ALARM POWER SUPPLY 15: 140 ;Auxiliary Device Current ! 0; 0 Notification Appliance Load (Max. Total / mA) 0 3397 i Tatal(A)=; • 15 Total(B)7 3537 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 3537 Total current ratings converted to amperes (line D x .001) 0.015 3.537 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 2 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.2946321 Add lines G and I Total Standby and Alarm AH 0.6546321 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.78555852 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP -HOUR *** Notification Appliance PROJECT: SARKU JAPAN Panel: EXISTING BPS PAD -3 REMOTE POWER Date: ;February 15, 2019 Circuit Detai SUPPLY W i re Resistance 2.58 CURRENT TOTAL= 3397.00 SET -MC -CW 75ct% SET -MC -CW (295cd ZR -M -CW @1Scd To l W i re Resistance . ( R ) .Total Device Load ,Amps (l) 1etg Drop e 200; 264 69. TOTAL mA= 397 :EOL Vol Wt.* 2 ) (Total Cct Lx ad) (E=l*R) ".v. 24-E) 1A7 0.40 0.58 23.42 SET -MC-' .SET -MC -ON SET -MC -CW S ET -MC -CW -Cwai5co_ DE1f}CES MAXIMUM LOAD 200 264 69 TOTAL mA=' ;TotaiWire Resistance C R ) fobt Device Lsd, Amps (i) ;Voltage Drop ( E ) 1500 24.00. J'L*.2.)(Ft tft) 'ota't c1 ;! $ )..... =1�R) 24E 1500 0.00 1.50 SET -MC -CW 15c SET -MC -1 03Ocd, S ET -MC -CW ©75cd 3ET-MC- N 095cc SET -MC -W Q11Ocd ZR MC -CW t 3{lcd DEVICES MAXIMUM LOAD 69: 111 200 264 233 111 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (l.) Voltage Drop (E EOL Voltage a! 0 a a, 24.00; (W L x 2) / (RtIt) (Total Cct Load) (E=I*R) 24-E) 1500 24.00 CALCULATIONS TO EXISTING SPEAKER CIRCUIT TO EXISTING BPS REMOTE BOOSTER POWER SUPPLY TO EXISTING DATA LOOP s,v S )001N( S1-1 30Cd D S1-2 30Cd HT -D S1-3 15Cd V D S1 -4 30Cd KITCHEN HOOD MONITOR EXISTING TENANT J -BOX SINGLE LINE DIAGRAM FLAG NOTES: HTRI-D MODULE FOR KITCHEN HOOD MONITOR. MOUNT STROBE ABOVE THE KITCHEN HOOD MANUAL PULL STATION. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ASH INGTON 1743 IST AVE. SO., SEATTLE, FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 0) T Y ! N 0 2 aaaaa "GALE: NOT cc 0 0 w z W z C!� 06 (1) z 0 E -- -J5 U U W F- C/) >- (J) TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/ 15/ 19 BACKROUND PLAN PROVIDED BY: \0B NUMBER:3801 1—/ SHEET FA -03 EXISTING ELECTRICAL PANELS 8'x 12' WALK-IN COOLER TO EXISTING TENANT JUNCTION BOX s,v 0 PREP. s,v EXISTING EXHAUST HOOD S1-2 30Cd D rJ rJ T; W l� 1 a 2 ANSUL CABINET f FR .mmmti ra gr11 Hieatiitvti :mom T -D 4 S1-3 1 5Cd Vii///////. e) S2-4 30Cd SERVICE II I FIRE ALARM SYSTEM PLAN of FLAG NOTES: HTRI-D MODULE FOR KITCHEN HOOD MONITOR. MOUNT STROBE ABOVE THE KITCHEN HOOD MANUAL PULL STATION. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. AH Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE rn uo N 0 2 aaaaa M 0 u_ z co ~ Q °' < 0 �; z W -42 CC CCz� ©CQ=_ CD w H- LL cc 0E— O O O N /SCALE: 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:02/15/19 BACKROUND PLAN PROVIDED BY: \0B NUMBER:3801 1-1j SHEET FA -04 1 E A A T KW ', ; A, As SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTErV INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL) FA -04 FIRE ALARM SYTEM FA -05 WESTFIELD SOUTHCENTER MALL SITE PLAN WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO 1416 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD 1412 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR : RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWO #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DMA TWISTED PAIR RATED , #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED 1418 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH• 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED . ON . 40% CONDUIT. FILL: AND ARE TAKEN FROM "N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED: 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED; . NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE,: FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE; :FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TOCONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR. CODE. CONDUCTORS SHALL BE PERMANENTLY,' AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS., ' 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF. NFPA 70; N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED. .AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR. TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON .A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL -BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH . A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2002 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2002 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 2 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD I" N LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE ®p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING gL C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. ILI FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM STROBE C (CEILING MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" : EXT. 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING a FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. Pc FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1 ;-1/2" EXT.. FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX W/ 1-1 /2" EXT. 80" A.F.F. TO BOTTOM WP MR FIRE ALARM STROBE (WEATHERPROOF) MULTI -VOLTAGE CONTROL RELAY SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2"PIPE IN FIELD. MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD ❑M MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FATC FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. VERIFY IN FIELD JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A UNLESS OTHERWISE U.❑.N. NOTED N/A __ N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A V1Gthoiat Cornments As Noted In Red P The Attached Letter I nese plans have liken reviewed by The Tukwila Fire Prevention Bureau ;or conformance with current city standards. Accect Ince is wu�".,iect to errors and omissions which Uc not authorize violations of adopted standards and or:?+ ;: r: s. 'The rewonsibility for the adequacy of de; v;r rest:::: totally with the designer. Additions, dole ictr s or;sAiisions o these drawings atter this date will voice th •:; acc tance rnd will require a resubmittal of;rovis:,d drrawings for subsequent approval. $Final acceptance is The Tukwila Fire Pr Date: y -g- (). :subject to field test and inspection by :vention Bureau. By: 511 GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A TUKWILA FIRE DEPARTMEN', Please call: 575-440Z and give this job No 08-F -// 2- and exact address for shut down or re:t:,ration approva$7 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result In a Re -inspection Fee and termination of the testing, Y��1( �hoh(tDr�Dc� partsII►o� Loo Svl,pregii'• Sy3J. X1154,4 l l0(IkGV` devic‹. oti o�ediCc41 F4 s. S4cr. etre(-0" %t -e41" -c -- S y s•6, 4 Cop! ui - ' N Fe4 7z loo e d r 1,-o1• _ , 'fl 2008 WASHINGTON 98134 -RELEASE/REVISIONS r CD LLJ CC -- DESCRIFTION- LIJ cb z C C Tukwsla Fire Copyright 2006 by Guardian Security Systems, Inc. All Rights Res ele DRAWN ;i t3Y:: I.ANDERSbN. DESIGNED';BY: R.vr ZZAN f DATE: 2/27/0 BACKROUND; PLAN PROVIDED BY: THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT t0'IDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AIR DUCT 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC o o o END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH $., 0 GROUND -0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 HTRI—R OSTATUS LED CO n t0 0 0 0 DUCT DETECTOR LOCATION N.O. COM N.C. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCALE PREVI❑US ADDRESSABLE DEVICE (BACKGOUND MUSIC SHUTDOWN) TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES, MAX. - MAX, CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX, LINE SIZE - MIN. LINE SIZE- OUTLET SAMPLING TUBE INLET SAMPLING—\, TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE MUSIC —1.) -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE {(-) FROM XLS CONTROL PANEL OR 1(¢1 PREVIOUS ADDRESSABLE DEVICE (-1 END OF LINE DEVICE (3.6K 1/4W) / / / SUPERVISED / RELAY CONTACTS SWITCH /% (4.0A @ 125VAC) GROUND ' (4.OA @ 30VDC) 27 VDC 3.5 rnA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0,02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST 25 SEC. TO GUARANTEE DETECTION. JOeI 0 1.23.4.56 HCP TB2 ma 65 -0 0 0 HTRI—D STATUS LED CO 0 0 NOT USED 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 CND N AC 0 El El 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 17, 1 2+ 2-..2 •NC- C N,O +. + - +._-• 1 A 241( TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END OF LINE DEVICE 3.6K 1/4W) `SUPERVISED SWITCH 1 FRONT MEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP ! O O FROM XLS CONTROL PANEL OR (4-)) PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS hi EOL 0 INPU 9 P Jp9 TSM -1 0 CC,(1C0 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL FROM. REMOTE POWER SUPPLY C'S' CABLE) FROM FRCP (VOICE CIRCUIT) ('V' CABLE) SCALE NONE EARTH GROUND ->(+)TO NEXT DEVICE OR 1 >(-) STOP IF LAST DEVICE J W-) �) STROBE SPEAKER. (+) ( ) ( STROBE ( STROBE-) SPEAKER +) � ) SPEAKERISTROBE AND STROBE WIRING LABEL SCALE NAC -4 NAC -3 NAC -2 NAC -1 SPEAKER STROBE OR STROBE ONLY R u 4S DEEP BOX W/ 1 -1/2 - EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERA�T�IN TEMPERA +32.F (0' C TO 100. F C) HUMIDITY: b0--9 % RELATIVE HUMIDITY. NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE {DATA IN (-) >--- DATA IN (-F) > DEUCE IS LISTED FOR AIR VOLOCITY APPUCA11ONS OF 300-4000 FT IN WEN USED IN CONJUNCTION TH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEMCE.ci ( ) DATA OUT (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID HARD LID CEILING -------SPEAKER SUPPORT TILE BRIDGE m LU ti / 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION \.. CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT JUNCTION BOX—, MOUNTED ON \ CEILING FLEX \. / 0 0 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE=NONE --- SUSPENDED ILLUMINATED CEILING Copyright 2006 by Guardian Security Systems, Inc. All. Rights Reserved RELEASE/REVISIONS DESCRIPTION CO CO pj W 0 CC cc OcT) ~< CC CO f t. Z 1 SCALE: DRAWN' BYi (.ANDERSON DESIGNED BY:. R.VEZZANI'; : DATE: 2/27/08 BACKROUND PLAN PROVIDED BY: . JOB NUMBER: . SHEET 2 0/110,11.1,"1,01.1,1* 1111 gEt. ------------ 2V,2S .r.g.Off Ll „„ *11.04.1, i; FfireleiWalff4W4R4 VAIPX170/9(4/AMISMIIIKOSIWAVARIVAIRWIRSMI=Cl 2V.2S —1 30; --------------------- 104, Oren! ; 4 • 1- • • ; • • Copyright 2006 b' Guardian Securit S stems, Inc. All R. hts Reserved •') ;;;;, „ • ; I i• ' : 1;,,, • FAX (206) 628-4.990 •, 1i • I DRAWN . By:, LAN DERSON DESIGNED • BY: R .VEZZAN I • DATE: 2/.27/08 I3ACKROUND PLAN PROVIDED BY: NUMBER: „ . SHEET -03 1., ••• 111' • .1, 4. •I ' ,!!! • ;1:i 11.1 t.t • 11 1 II • 11 I 1 1;1 1 +•1; I • 1,11 • 111 „I 1 .11 t•,; •4; 111 ''.-;t .t,' "'I" „,,;•; . , "", • y" 4i ".,,, ,!. ".! -7 ...,— CD CY';, CJ cn LU 0 ;" •, t'. t,'c it:, 1 4., 7.! ' •''.1., :, 1'. „„,..-t;, r,;:: II ); ; l'.•Iii•,.-t; I; I'";•••:11!, 1" ; - '1' '17: .!.•! !!q' r•'.: •" 7.'".. , ' .,4;-.'; r,f,;'.".„f.., „ .., ... ,•-;... ;•„; 6i, .••'• ' i, •;„;„. • '1: . •1 ' , • ' ' • t ' ,, • , ;I' tiii <C 0 i,I ,tr• ,; ;• "' ,: 1; i 1!„- ', ' • ' • :. , ' . Z 6,„, < •, ,:. <<<< DRAWN . By:, LAN DERSON DESIGNED • BY: R .VEZZAN I • DATE: 2/.27/08 I3ACKROUND PLAN PROVIDED BY: NUMBER: „ . SHEET -03 1., ••• 111' • .1, 4. •I ' ,!!! • ;1:i 11.1 t.t • 11 1 II • 11 I 1 1;1 1 +•1; I • 1,11 • 111 „I 1 ! t --1--, /- , „...------ t.1 d-- -a *•,.. \!, A 1 \ '......,\ ../' v, ,, ir; 1-;,A .....A 1, . t trtt.,..;.....l' . i 1 jj ":"../..., 1, - ---- .---_,- \ ' \ --0; \\'• j --- 0 0 --- ...... \ NORTH CONCEPT 5 WESTFIELD SOUTHCENTER MALL SCALE 1/32":11 {120VAC 20A DEDICATED CIRCUIT BY OTHERS R SER DIAGRAM • SYSTEM CALCULATIONS xxxx RECOMMENDED MINIMUM BATTERY SIZE = 7,00 AmperexHours ATTERY SIZING CALCULATION '`4••11 , Date: !April 3; 2008 • • Notification Appliance Circuit Detail PROJECT: 1WESTFIELD SOUTHCENTER MALL Panel: iSARKU !Wire Resistance 3 24 CURRENT TOTAL= 273 i , 1 CIRCUIT:iS1 ; QTY I Device Type Alarm Currents,' Alarm Total ; VVire Size 1 VVire Length ! Voltage at EOL ' Circuit Total 1 , , I i 64 CO , 1 1 ; i Total Wire Resistance ( R ) 1 0 1SET-MC ©15CD ' 1 4 1.301 ;1 I , • 1.4') 00 0\ 3 IST AVE. SO., SEATTLE, WASHINGTON •1 FAX (206) 628-4990 TEL. (206) 622-6545 0 ET) 5 uJ Lid LU uJ c ,• 14 •=•.;';„:" CC ,.„ ' •,... 0 SET -MC ©110CD 1 0 1 : )SET -MC ©75CD 4 iZR-MC ©15CD 1 t " ; _2331 175 98! 1 _ 0 175i s 1 I , - 4 , 1 , t 1 .; ? 1 ;Total Device Load, Amps (1) I i , 1 (Total Cct Load) .. , t 0c:2375 if!' . t 1 SET -MC @30CD i 98i i t ; , t i 1 { ( WL * 2 )* (R/ft) 641 Oi ; 1 ; I -t ;Voltage Drop ( E ) ., ;;;;; 0 ZR-MCi@30CD I ; 98i 0 i I (E= I * R) ' 1 f 0 1ZR-MC @75CD t 1 1751 i1 1i ci 0 c Ic,E EOL Volage 20.051 0 ZR-MC110CD 233i 0 i , (20.4-E) 1--------------------------''11 1 t i i; . 0i i 1t ; i 1 DEVICS-=;2 1 TOTAL mA=I 273 12 1 200 20.0461921 273 i i 1 , t 1 i : . Notification Appliance Circuit Detail'' 1 _ ,.1.. I.,. PROJECT:1WESTFIELD SOUTHCENTER MALL, , : i 1 • . ! .., , Panel: ISARKU& Wire Resistance •16 ; e , • , .I ; Date: i April 3;,2008. :. '; : H. . • : : ' . • 1 ' CURRENT TOTAL=13.6 . 1 , .CIRCUIT•SPEAKER CIRCUIT ...1 ! ' i , . QTY De i 1 - : ti. Deice Type 1 '„,Alarrn CUrrentiuAlarm Total; 1 Wire 8ize I VVii-e Length Voltage at EOL i :ti it Total ' .I ..c:- ..... I CircU c , 70.7V 118 2 .1.81 ., 3.61 1 , 4 'I : ' '' . 1 i 'ITotal Wire Resistance ( R ) ; 2.06 . 0 03 0i . i i . (' WL * 2 )* (Rift) 0 0- 01 1 Total - "-• - Device Load, Amps (I), ,‘- 0.00 0„ - -i 1 1 i.(Total Cct Load) 0 O(1yoltage Drop (E) 0.01 . , . . i, , ' ..... .. 1 ,.,. .( E,= I * R). ..",, : : I 0 1 IEOL;VOltage20 .39 .. e .'' - . ' - . '' ,' .10 ' ' ' . ' 1 . .,, ,.. ,'- ; .:,c;..• .;. -. ;11 :': ' ! ed';: 1 . ' (;2 0:4 - E) • ,H 0 ; 0 0 i i 0 i 1 0 i 1 1 ' . . i L i . . . ' , c 20.3925696! ..' TOTAL m A.,! t 3.6 12 200 3.6 , i• ; i • DEVICES=i2 TAGE DROP CALCULATION • ' . . . • . • •.• . . . • .1•;;j! ; ; . I ' Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved DRAWN ;BY: 1.,ANOERSON DESIGNED BY: R,.YEZZANI BACKROUND.;PLAN PROVIDED BY: • 08;NUMBER• , • ; • SHEET -o t SARKU SARKU FACP ADD ONS SIEMAENS PAD -3 Signal Extender Panel Battery Load Calculations Current Load: Standby: Alarm: Current Load: Standby: Alarm: ; ; , , Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 AD2-P 2 0.0635 0.0635 0.064 0.128 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R HTRI-D ._ ;4. 2 �009600 0.0096 0.021 0.042 SET -MC @15CD SET -MC @30CD SET -MC @75CD 0.064 0:001600 0.0035 1 0.098 0.098 i 1 0.175 0.175 SET411C @110CD 24-nia. 618cp ZR -MC @30CD ... „ . HCP 0.233 .. . . 0.064 . ' , 0.098 0.0731 Amps 0.17 Amps 0.0015 ` e 0.03 Amps 0.303 Amps Standby COI -rent Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours !, I Alarm Current Load: , 0.17 Amps For 5 Minutes= 0.014 Amp -hours -1! Alarm Current Load: 0.303 Amps For 5 Minutes= 0.025 Amp -hours 25% Derating= 2.211 Amp -hours 25% Derating= 0.932 Amp -hours : • ;; ' fl Total System Current Load: 2.211 Amp -hours ;11 . Total System Current Load: 0.932 Amp -hours U Battery Pi to be Used: 12VDC Amp -hours 7AH . • t ; -i. :; • Battery Pair to be Used: 12VDC Amp -hours 7AH • g xxxx RECOMMENDED MINIMUM BATTERY SIZE = 7,00 AmperexHours ATTERY SIZING CALCULATION '`4••11 , Date: !April 3; 2008 • • Notification Appliance Circuit Detail PROJECT: 1WESTFIELD SOUTHCENTER MALL Panel: iSARKU !Wire Resistance 3 24 CURRENT TOTAL= 273 i , 1 CIRCUIT:iS1 ; QTY I Device Type Alarm Currents,' Alarm Total ; VVire Size 1 VVire Length ! Voltage at EOL ' Circuit Total 1 , , I i 64 CO , 1 1 ; i Total Wire Resistance ( R ) 1 0 1SET-MC ©15CD ' 1 4 1.301 ;1 I , • 1.4') 00 0\ 3 IST AVE. SO., SEATTLE, WASHINGTON •1 FAX (206) 628-4990 TEL. (206) 622-6545 0 ET) 5 uJ Lid LU uJ c ,• 14 •=•.;';„:" CC ,.„ ' •,... 0 SET -MC ©110CD 1 0 1 : )SET -MC ©75CD 4 iZR-MC ©15CD 1 t " ; _2331 175 98! 1 _ 0 175i s 1 I , - 4 , 1 , t 1 .; ? 1 ;Total Device Load, Amps (1) I i , 1 (Total Cct Load) .. , t 0c:2375 if!' . t 1 SET -MC @30CD i 98i i t ; , t i 1 { ( WL * 2 )* (R/ft) 641 Oi ; 1 ; I -t ;Voltage Drop ( E ) ., ;;;;; 0 ZR-MCi@30CD I ; 98i 0 i I (E= I * R) ' 1 f 0 1ZR-MC @75CD t 1 1751 i1 1i ci 0 c Ic,E EOL Volage 20.051 0 ZR-MC110CD 233i 0 i , (20.4-E) 1--------------------------''11 1 t i i; . 0i i 1t ; i 1 DEVICS-=;2 1 TOTAL mA=I 273 12 1 200 20.0461921 273 i i 1 , t 1 i : . Notification Appliance Circuit Detail'' 1 _ ,.1.. I.,. PROJECT:1WESTFIELD SOUTHCENTER MALL, , : i 1 • . ! .., , Panel: ISARKU& Wire Resistance •16 ; e , • , .I ; Date: i April 3;,2008. :. '; : H. . • : : ' . • 1 ' CURRENT TOTAL=13.6 . 1 , .CIRCUIT•SPEAKER CIRCUIT ...1 ! ' i , . QTY De i 1 - : ti. Deice Type 1 '„,Alarrn CUrrentiuAlarm Total; 1 Wire 8ize I VVii-e Length Voltage at EOL i :ti it Total ' .I ..c:- ..... I CircU c , 70.7V 118 2 .1.81 ., 3.61 1 , 4 'I : ' '' . 1 i 'ITotal Wire Resistance ( R ) ; 2.06 . 0 03 0i . i i . (' WL * 2 )* (Rift) 0 0- 01 1 Total - "-• - Device Load, Amps (I), ,‘- 0.00 0„ - -i 1 1 i.(Total Cct Load) 0 O(1yoltage Drop (E) 0.01 . , . . i, , ' ..... .. 1 ,.,. .( E,= I * R). ..",, : : I 0 1 IEOL;VOltage20 .39 .. e .'' - . ' - . '' ,' .10 ' ' ' . ' 1 . .,, ,.. ,'- ; .:,c;..• .;. -. ;11 :': ' ! ed';: 1 . ' (;2 0:4 - E) • ,H 0 ; 0 0 i i 0 i 1 0 i 1 1 ' . . i L i . . . ' , c 20.3925696! ..' TOTAL m A.,! t 3.6 12 200 3.6 , i• ; i • DEVICES=i2 TAGE DROP CALCULATION • ' . . . • . • •.• . . . • .1•;;j! ; ; . I ' Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved DRAWN ;BY: 1.,ANOERSON DESIGNED BY: R,.YEZZANI BACKROUND.;PLAN PROVIDED BY: • 08;NUMBER• , • ; • SHEET -o t 07077.,, ;41 A El; Without Comments As Noted in Red Per The Attached Letter INSTALL FRP ON 5/8" GYP. BD. FASTENED TO METAL STUD FROM TOP OF WALK—IN COOLER TO U/S OF FINISHED CEILING (WP 1-iese plans have been reviewed by The Tukwila Fire BUreau for conformance with current City ..andards. Acceptance is subject to errors and • .iiissions which do not author12.e ‘tiolatinnof adopted, .•,,ndardsandordinance's, The responsibillty l'or the •--..!equacy of desion rests totally with the drezIgner, ;Additions, deletions or revisions to the.;;..-; drawings after • tms date will mid this .icceptance and wiii require iesubrnftta of-feYised drawings for subsequent approvc<1. • • • Final acceptanceis subject to field test and inspection by . The.TUkwila Fire Prevention Bureau. Date' ti . -"I Bv:/-f 1 ( TUKWILA DEi-siARTAL'..31 Piea5zaH 206-575-44W F]rid give, Five, No. and exact addrzss for shut- down or restoration approval, '• / \i \ // 1,P4A _ \ OPEN CEILING • • • TO STRUCTURE ABOVE • ADD D.V.R. CABINET & CABLING 12" AWAY FROM T—BAR CEILING DETAIL REPLACE HVAC RETURN AIR DIFFUSER EXISTING SOFFIT Si SERVICE/ CLEAN EXISTING EXHAUST DUCT SERVICE HVAC, MUA, EXHAUST FANS & ROOFTOP PROTECTION EXISTING FIRE ALARM TO REMAIN REPLACE STOREFRONT SIGNS (SHOP DRAWING TO BE SUBMITTED TO LANDLORD FOR APPROVAL BY MANUFACTURER SEPARATELY) REPLACE REPLACE EXIT LIGHT EMERGENCY LIGHT I I • • , PREP. 11 HATCHED AREA INDICATED 77(P12'-0" A.F.F. RAISED UP CEILING DETAIL 06 ///// ////7 WP2 —37 . REPAIR & RE—PAINT T—BAR GRID, I • I REPLACE VINYL CLAD CEILING TILES • J -(1)- 4 *1 ... -4E13 I I I I + SERVICE I L EFLECTED C El LI \ G PLA\ EXISTING JAPANESE SCREEN AROUND EXISTING EXHAUST HOOD SHOWN DOTTED (SEE ELEVATION) EXISTING H000 ENCLOSURE • TO REMAIN SERVICE/ CLEAN EXISTING EXHAUST DUCT REPLACE FLUORESCENT LED LIGHT FIXTURE, RECESSED TROFFER 2'x4' REPLACE HVAC SUPPLY AIR DIFFUSER (DIFFUSER TO BE HINGED TYPE, TO FACILITATE FILTER) EXISTING UST E-3-0—ArD E INSERT ONLY) RE—PAINT EXISTING DRYWALL CEILING IN WHITE ADD DigLIA (SErtLEVATION) U DISPLAY REPLACE BLADE SIGN REPLACE RECESS DOWN LIGHT (TYPICAL) SCALE: 1/4" = 1'-0" Design per NFPA 13 — Ordinary Hazard Group 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions • 1 — Add Globe GL5680 Quick Response 200° Dry Pendent % x % EXISTING SOFFIT . .. . &:•- FlexHead Sprinkler Drop . • . • • . . . • • '. • . • .. Cofrugated stainless steel hose with stairiless steel bral • available In 2, 3,4',5' & 6' legnths . • kulli-PortBrackei • Adjustable Hub R ---.1mmumemmirjommommimmip, FLthyBEAD •• • • • • .• • F:loxheatbmne.. rola, cOiling Unit T -Bar Ceiling Installation . • • Model #2024,036,2048,06O,2072 0 I a, ;047,0 • RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C—CLAMP. • WITH SET SCREW • 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL ..113 IST/TRUSS • HANGER DETAIL. NTS 8ARKU JAPAN SPACED FC -3 LEVEL: 02 OF 3 SO. FT. 816 • 0 • 4Lo1-( v‘to • * o • • • o' • • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Project • Sarku japan • WESTFIELD SOUTHCENTER (SPACE# FC -3)• 240Vi3Var SOUTH CENTER PARKWAY *TUKWILA, WA 98188-2888 DATE: j aid . DRAWN: d / I SCALE: .1.• • • ••• 1r4 ID c\A • Fa -3 0- 2019 k, TV. ILA FIRE .Z71 7'e. eza; Wthout Comments M Noted in Red Per The Attached Letter 1 uttWILA FIRE DEPARTMENt'it Please call: 575-440Z _end give this job Jo. _ ,rld exact address for shut+ ,n or restoration approval: = i nese plans have rovic.wed by The Tukwila Fire Prevention Bureau ,'pr cci:iorrlla.rice with current city standards. Acc,ew:: r1t;t: i;.. to errors and omissions whio11 i:)cJ viulstion:s U1 adopted standards and roL perlSibitit jr for the adequacy or d€ Sigh r; ::.'; . 1(?L9++v 'v:rliil tt'i(•; designer. Additions, c ef:.:i!)ris or I;:vi ;ipn`:_ h; the.e. drawings ratter this date will void Lill, ac copt;_;nc€ unci will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire, Prevention Bureau., AT Date: L//)1 ° K By: A-141 3// i ut\VVIL.A FIRE DEPARTMENL Please call: 575-4407 and give this job No. d3S — /I `/ and exact address for shut.' Town or restoration approval: AlanCE. Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic test approval. WALK• I /•,LK I I COOLER BELOW WALK-IN FREEZER BELOW CONSTRUCTION NOTES: a GENERAL NOTES: ) 1) PIPE: THREADED: STEEL, SCH 40, BLACK, IMPORT. GROOVED: STEEL, SCH 10, BLACK, IMPORT. 2) FITTINGS: GROOVED: STAR STANDARD - ORANGE PAINT FINISH THREADED: STAR D.I. 3) GROOVED COUPLINGS: STAR RIGID C-4 UNLESS MARKED WITH AN "F", WHICH ARE TO BE STAR FLEXIBLE C-3 LW - ORANGE PAINT FINISH 4) HANGER MATERIAL: ALL HANGER MATERIAL IS TO BE FINISHED BLACK OR STANDARD LIST OF ELEVATIONS:) EXISTING SPRINKLER PIPE 4. @ 16'-0" FINISHED FLOOR TO BOD = FINISHED FLOOR TO BOB = ACT CEILING HEIGHT = I0'-0" GWB CEILING HEIGHT = 12'-6" SYMBOL LEGEND:) = EXISTING AUTOMATIC UPRIGHT SPRINKLER.` = EXISTING AUTOMATIC PENDANT SPRINKLER • = NEW RECESSED PENDANT ON DROP • = NEW CONCEALED PENDANT ON DROP • = NEW DRY PENDANT s----5 = EXISTING SPRINKLER PIPE — NEW SPRINKLER PIPING 1/4" MIN SYSTEMS ARE DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF N.F.P.A. 13-2007 ED., THE CONTRACT DOCUMENTS, AND THE CITY OF TU KWI LA. CRITERIA: OCCUPANCY: LIGHT HAZARD, AND ORDINARY HAZARD GROUP I. LIGHT HAZARD SPRINKLER SPACING: 225ft2 MAX. ORDINARY HAZARD GROUP I SPRINKLER SPACING: 130 ft2 MAX: 2) COSCO'S POINT OF CONNECTION IS AT EXISTING SYSTEM A5 SHOWN. 3) ALL PAINTING OR PREP OF FIRE SPRINKLER PIPING ( IF REQ.. ) TO BE DONE BY OTHER. 4) ALL WIRING OF SYSTEM DEVICES IS BY OTHER. 5) OWNER IS RESPONSIBLE TO ASSURE THAT THE STRUCTURE, AS IT IS SHOWN ON THE CONTRACT DRAWINGS, CAN ADEQUATELY SUPPORT THE FIRE SPRINKLER PIPING. NO AUXILIARY DEVICES OR ATTACHMENTS SHALL BE PROVIDED BY COSCO TO SUPPLEMENT THE STRUCTURE. G) OWNER IS RESPONSIBLE TO PROVIDE ADEQUATE HEAT TO MAINTAIN 40° F. MINIMUM AT ALL TIMES. 7) OWNER IS RESPONSIBLE TO ARRANGE FOR THE PERIODIC INSPECTION, TESTING, AND MAINTENANCE OF THESE FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF N.F.P.A. 25-2002 ED., BY QUALIFIED PERSONNEL COMMENCING AFTER WARRANTY PERIOD HAS EXPIRED. THE FIRM THAT DESIGNED AND INSTALLED THE SYSTEM(S) IS BEST QUALIFIED TO PROVIDE THE ONGOING LONG TERM TESTING, MAINTENANCE, AND SERVICING. 8) ANY RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE OR CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIED OR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO FIRE PROTECTION. HILTI KWIK BOLT 3 ANCHOR ICC REPORT #ESR -1385 MIN. OF 3,000 PSI CONCRETE MIN. 3 I/4" CONCRETE OVER MAX. 3' METAL DECK 3/8' ANCHOR W/20# TORQUE: TENSION=395#,SHEAR=750#• 1/2" ANCHOR W/40# TORQUE: TENSION=440#,SHEAR=750#• •fH WI LOADS HAVE®! RHI.C® BY DM FOR THEM TIRI THREADS ROD COUPLING THREADED ROD PIPE SIZE ROD DIA. BOLT LGTH IMBED DEPTH HILTI FIG. LH OR TOLCO FIG. 200 HANGER RING UL 04/2007 I COSCO STANDARD HANGER I 13 MDL EXISTING SSU 1" ' SEE PLAN FOR LENGTH REMOVE EXISTING z 1"SPRIG INSTALL . w NEW 1"x0-4 NIPPLE LLJ W "' O LL EXISTING BRANCH LINE ADJUSTABLE DROP NIPPLE AT GYP BOARD CEILINGS lx 1/2 RC AT AC TILE CEILINGS CEILING EXISTING SSU SEE PLAN FOR LENGTH PREP i REMOVE EXISTING 1" SPRIG INSTALL NEW 1"x0-4 NIPPLE SEE PLAN FOR LENGTH EXISTING BRANCH LINE ADJUSTABLE DROP NIPPLE AT GYP BOARD CEILINGS 1x 1/2 RC AT AC TILE CEILINGS CEILING A TYPICAL ARMOVER TO NEW SPRINKLER HEAD N.T.S. y211 N JOB SITE ''r` t`u x'' 5.152nd aE1'ICE baniel McLu n 391-076676 SARKU JAPAN SCALE: Y2" = 11-O" Yin Vii';, .:: °$ 1s6cr, 2008 SPRINKLER HEAD LEGEND : SYMBOL S/N ORIFICE Reliable Model F1 FR Recessed Pendant Reliable Model FI FR Concealed Pendant Reliable Model F3QR Standard Dry Pendart (A =18) 1/2' 1/2' 1/2' NPT 1/2' 1/2' 1/2' K•FACT. 5.6 5.6 5.6 HEAD FINISH Chrome Chrome Chrome PLATE FINISH Chrome Chrome Chrome TEMP. 155° 155° 200° QUAN. 6 3 2 • 0 0 00o0. • oO 00 00• '000000• • 0®®• APPROVALS BY: TOTAL SPRINKLERS THIS SHEET 11 Icosco Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS WASHINGTON OFFICE 10910 117TH Place N.E. License No: Kirkland, Washington 98033 COSCOFP1 IONM call (425) 827-9654 • fax (425) 827-7474 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE • ANCHORAGE www.coscorire.com PROJECT: Sarku Japan Southcenter Mall Foodcourt a4640 6)&Southcenter Mall Sucre-- Fc ---5 Tukwila, Wa. 98188 DATE : April 2008 SCALE : As Noted DRAWN BY : Justin Johnson CONTRACT WITH: Woodburn Construction P.O. Box 129 Woodbum, Or. 97071 (757) 291-4743 DRAWING ITU Piping Plan: Sarku Japan (Space # FC -3 TI) SHEET NO. 1of1 `�1