Loading...
HomeMy WebLinkAboutPP - 1387 SOUTHCENTER MALL - BODY JEWELRY PLUS - PERMITS AND PLANS1387 SOUTHCENTER MALL ASSOCIATED PERMITS 13-F-071 16-S-098 ITZMAN SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** O.' �% /)King Co. Assessor's Tax No.: (2(i�`J OO I 0 Site Address: 1 mais Suite Number: CC 3O Floor: Tenant Name: ° I t () f / �� �� — ci fJ2 "(Q New Tenant? - Yes ❑ - No Property Owner's Name: Y\1 0 Mailing Address: City CONTACT PERSON -if there are questions about the submittal. Name: KARINA VELIZ Day Telephone: 206-734-6276 x229 Company Name: GUARDIAN SECURITY SYSTEMS. INC Mailing Address: 1743 - 1ST AVE S SEATTLE . WA 98134 City State Zip E-mail Address: kveliz@guard iansecur ity. corn Fax Number: 206-341-9928 State Zip Valuation of Project (contractor's bid price): $ '-5-6() Scope of Work (please provide detailed information): I�GI vtX(5k ( n pcvAa - 4i13 L1 cLvv cu PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER OR AUTHORjED AGENT: Signature: Print Name: Plan Permit App.doc k Date: ' 22 C\V � v e t Day Telephone: 1)-(A) "I• v 2.6( 5/1 4/1 0 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: MOR Beauty 1387 Southcenter Mall Permit No.: 16-S-098 Date: May 11, 2016 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. Without CofIirlteril`S As Note!? Per The Ati. rciii:;, letter These plans have 'leen r ev Ieuvea by 1•he 'Tukwila Fire Prevention Bureau ,cr: .::orlforrnanc. with current City st-ndards. iuoje t rs • errors and orni sions whid.. ;t,-,otnortzr-: ,,,olauons of adopted sV:inciaros ano f,r',';; •:,r yr' .; rho rnsoonsibriity for the v'th Cif.? designer, • •r1sq.Ins tr1 Ihe;.rr, or?)viiinys after c1dequacy of de"1r1 /additions., ielc .to -. this dateMOvoid t? . .-C,epcar,c€ and vdili require a tesubrnitl C%i Iii t,,: ti l: �.'` •.`Vi ngs fry 5(.10F:egl.lent approval. Final accepi'anc(7 yield test ano inspection by The Tukwila Fire P.evehr. _:,:- furreeau. Date: � 11- /L =•,r: / V "' ( r f.R ' DEPARTMENT and »5v,, thi, ';i7h•.' i'a d mit: No. and caceict a,dd tss for shut- down or r storMCn approval). • 0 EXISTING CHOW KING NEW CEILING/SOFFIT/BULKHEAD - SIMILAR TO PIRSHOKY'S (NEXT DOOR) MOR BEAUTY TENANT SPACE EXISTING PIROSHKY'S * FIELD VERIFY ALL DIMENSIONS 25'-7" ALIGN 01 01 ieo EXIST. EXIT DOORS TO REMAIN REFLECTED CEILING PLAN SCALE: 1/4" = 1'-O" Design per NFPA 13, Ordinary Hazard Group 2 / Retail All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilins, or any other means All heads to be at least 6' apart ;0 14 ® 4 – Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 TOTAL - 4 •• FlexHead Sprinkler Drop . OlMI t, (,'`=Rt;54, Cofrugated stainless steel hose with stainless steel brat `:..;:; %available In 2', 3',4',5' & 6' legnths •. • Multi -Port Bracket • Adjustable Hub • .1 Ftl<EAD 1 ousraies ' • Flexhe6c1 omme'rcial Ceiling Unit T -Bar Ceiling Installation . Model #2024,2036,2048,2060,2072 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS MALL KEY PLAN a 1- L.evei 1 1� Andover Park W. g Family Parking LANDLOI WORK = MOR BEAUTY •i ; • ®O fco - a W a W = i' NOTON STATE OERTIF • TE OF COMPETENCY FIRE PROTEC ON SPRINKLER SYSTEMS John J. Abel 9760-06914volG 3 F • NOT TO SCALE CROWN FIRE. PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 MOR Beauty 1387 Southcenter Mall Space # C-21 Tukwila, WA 98188 TI DATE: • o5., `(a DRAWN: 0 SCALE: 119 16 I Expires 12131118 PAID iq10 21115 KW1LA FIRE -2/Yc) Iiov ..... ....................................................................... ...44; '.:.. -- - • Fa................... :i.it!•.....••• ..::. ::— l• •:::.: :�. ��:•::.:•::�:��:�:�:•:• ?i sir?:-}i:•::i{i:- .... : ..... EXIST. ALIGN NEW LIGHT FIXTURE W/ — EXISTING STOREFRONT FIXTURES, TYP. OF 6 7'-8 1/2" = 12" T-113/4" STOREFRONT/DOOR TO REMAIN / / 1\ EXIST. EXIT DOORS TO REMAIN REFLECTED CEILING PLAN SCALE: 1/4" = 1'-O" Design per NFPA 13, Ordinary Hazard Group 2 / Retail All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilins, or any other means All heads to be at least 6' apart ;0 14 ® 4 – Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 TOTAL - 4 •• FlexHead Sprinkler Drop . OlMI t, (,'`=Rt;54, Cofrugated stainless steel hose with stainless steel brat `:..;:; %available In 2', 3',4',5' & 6' legnths •. • Multi -Port Bracket • Adjustable Hub • .1 Ftl<EAD 1 ousraies ' • Flexhe6c1 omme'rcial Ceiling Unit T -Bar Ceiling Installation . Model #2024,2036,2048,2060,2072 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS MALL KEY PLAN a 1- L.evei 1 1� Andover Park W. g Family Parking LANDLOI WORK = MOR BEAUTY •i ; • ®O fco - a W a W = i' NOTON STATE OERTIF • TE OF COMPETENCY FIRE PROTEC ON SPRINKLER SYSTEMS John J. Abel 9760-06914volG 3 F • NOT TO SCALE CROWN FIRE. PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 MOR Beauty 1387 Southcenter Mall Space # C-21 Tukwila, WA 98188 TI DATE: • o5., `(a DRAWN: 0 SCALE: 119 16 I Expires 12131118 PAID iq10 21115 KW1LA FIRE -2/Yc) Iiov SITE LOCATION Site Address: Tenant Name: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** GS7 Sou-i-liCC*r' Y1a('Reaofi/, Property Owner's Name: .eS* \-E'�C1, rn5%Yl\ (-rh9 King Co. Assessor's Tax No.: Suite Number: C—UII , Floor: Mailing Address: New Tenant? la -r_ Yes ❑ - No CONTACT PERSON -if there are questions about the submittal. Name: City Company Name: CA'Q\j)Y\ 1 r.Q FrWC- lc%), )Ylc State Zip Day Telephone: _?'Z 9 /' 766 Mailing.Address: CV gox / JL3 ynJll Cr-e6k; City E-mail Address: 1 411 a' 0 State Zip Fax Number: 112 — , RI 's(44 S" Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $_�f jj Scope of Work (please provide detailed information): AM, (Li) )7'aels PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in • writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. z . • I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW J ER OR AUTHORIZED AGENT: awca-P deJsk21;R as47) Signature: Print Name: Plan Permit App.doc Date: 5'5 'AO Day Telephone: 1-.0-4181•7401 1/2/13 TFD FP Form 8 Bulletin 034 Rev. C Model G5-80, Model G5-56, ReliableModel G5-42, Model G5-28 Quick Response Concealed Automatic Sprinkler 'uo iku. tt ,d v� r, �.nt,✓ sr ,,:a.,.,r a�, r�,u � .r..�.��HL3 �s a��,rt�a„�4 x C`�sn,J :?. l be it„t'i si rti, ..�� UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4" (19mm) Adjustment Features 1. Cover plate attachment (Plain or Perforated) with 3/4" (19mm) assembly adjustment. 2. Smooth aesthetic ceiling profile. 3. Factory installed protective cap. 4. Available in Chrome and White as Standard Finish- es. Special Application Finishes are also available. 5. Ordinary and Intermediate temperature rating. For additional Sprinklers refer to Bulletin 154 for Technical Specification and Approvals Approvals & Listings 1. Underwriters Laboratories Inc. and cULus - Quick Response • G5-80, G5-56 - Light Hazard and Ordinary Hazard Occupancies • G5-42 - Light Hazard Occupancies • G5-28 - Light Hazard Occupancies 2. Factory Mutual Research Corp. (FM) - Standard Response (See Page 3) • See the most recent FM Global Property Loss Prevention Data Sheets for installation and use guidelines. 3. Loss Prevention Council (LPCB, UK) - Standard Response • G5-56 - Light Hazard and Ordinary Hazard Occupancies 4. VdS Schadenverhutung GmbH - Standard Response 5. EC -Certificate of Conformity 0832 -CPD -2062 U.S. Patent number 6,554,077. Application The Reliable Model G5-80, G5-56, G5-42 and G5-28 are the most versatile quick response concealed sprinklers avail- able. It provides the best form of fire protection while offering an attractive appearance and 3/4" (19mm) of cover adjust- ment for ease of installation. The small diameter cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an au- tomatic sprinkler system. Plain Cover Plate Perforated Cover Plate The Model G5-80, G5-56, G5-42 and G5-28 are designed for use where aesthetic appearance is important. Offices, hos- pitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13. FM Approves the G5-56 and the G5-28 sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. The Reliable Automatic Sprinkler Co., Inc., 103 Product Description The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides 3/4" (19mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. Fairview Park Drive, Elmsford, New York 10523 5 Installation Do not install the G5-80, G5-56, G5-42 and G5-28 in ceilings which have positive pressure in the space above. • Cut a 25/" inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/ CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G5-80, G5-56, G5-42 and G5-28 should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. Concealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Ordering Information 1. Sprinkler Model 2. Nominal Orifice 3. Flat Cover Plate Plain or Perforated 4. Flat Cover Plate Assembly Finish 5. Inlet Type Cover Plate Finishest'> Standard Finishes Chrome White Paint Special Application Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome 2. 1) Other finishes and colors are available on special order, Consult factory for details. Coverplate custom paint is semi -gloss, unless specified otherwise. e) For the perforated style cover - plate, consult factory for avail- ability on these and other cus- tom finishes. Model FC Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Maximum Working Pressure 175 psi (12 bar) 100% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating Classification Sprinkler Cover Plate Max. Ambient Temp. Ordinary 165°F/74°C 135°F/57°C 100°F/38°C Intermediate 212°F/100°C 165°F/74°C 150°F/66°C Technical Data Sprinkler Model Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor Thread Approvals Sprinkler Identification (SIN) US Metric G5-80 Non Adjustable 3/a" (19mm) 17/32" (15mm) 8.0 115 3/a" NPT (R3A) 1 RA3412 G5-56 Non Adjustable 3/4" (19mm) 1/2" (15mm) 5.6 80 1/2" NPT (R1/2) 1,2,3,4,5 RA3415 G5-42 Non Adjustable 3/a" (19mm) 1/16" (10mm) 4.2 60 1" NPT (R1/2) 1 RA3413 G5-28 Non Adjustable 3/a" (19mm) 3/" (10mm) 2.8 40 1/2" NPT (R1/2) 1,2 RA3411 For VdS Approval, temperature rating sprinkler 165°F/74°c and cover plate 135°F/57°C only! 1" x 1/2" REDUCING TEE OR ELBOW tT I II 1" x 3/4" REDUCING TEE ORRELBOW G5-80 ONLY 2" [58.42mm] DIA CUP 23" [66.55mm3 HOLE IN CEILING 1 2-1/4" [50.8mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING i" [19.O5mm] MAX. _ COVER ADJUSTMENT FLAT COVER PLATE ASSEMBLY OJ4F001A " [84.21 mm] DIA. SPRINKLER th" [4.96mm] COVER PLATE: 3/4 " [ 19.05mm 7 ADJUSTMENT Notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS x 1/2' REDUCING TEE OR ELBOW - II I II IT 1 11, IL ill -- r RELIABLE P/N 699999190011 }' X' BRASS NIPPLE EXT.\ I 211' (58.42mm] DIA CUP CEILING Val 23' [66.55mm] HOLE IN CEILING //////// 3-1/16• [77.72mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 2-1/4' [50.8mm] MAX. FACE OF NIPPLE EXT. TO FACE OF CEILING DIMENSION i' [19.05mmJ MAX. — COVER ADJUSTMENT FLAT COVER PLATE ASSEMBLY ONFVD2 SPRINKLER 37.1" [84.21 mm] DIA. ti' [4.96mm] COVER PLATE: 3/4" [19.05mm] ADJUSTMENT NOTE: 1. Testing has shown that use of a "nipple extension" will not affect the listing of the sprinkler. 2. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, "which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems". 3. Do not exceed 8-18 ft -lbs of torque during installation. 3. I. eliable.e.For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address rit tali Recycled Paper Revision lines indicate updated or new data, EG. Printed in U.S.A. 11(13 P/N 9999970421 DDITION N SHEET \UV 3E SHEET TITL FA -01 SYSTEV \FOPVATIO\ FA -02 TYPICAL WHI\ G A\3 IVOU\ TI\ G DETAILS FA -03 SYST V CALCULATIO\S A\ D SI\GLE LI\E DIAGRAM FA -04 FHE ALA V SYSTEV PLA\ likrithou+. (,mono .-It5 Ash1t.,,i: -2 i feed p Per The Att ached Letter plans have. been t Ceviev,wcd by The Tukwila Fire . :: mon Bur";z:•i iron conformance 'F Eri; current City •a ; .Suo jecterrors and �,;�� CtS. J1,a::. t'i•...., , ,. is ! ,..v to violations of adopted ?'.,Fircis and ' rill ir'r,'. ces, The responsibility for the ?uuary of d: sir'!i i totally with the designer. i,ti c 1:•, : r'r i `vi{sIors to t;hese drawings after date will void ::rill,"•, .': 'pr'i'ce and will require a resubmittal of reviri r: <i; I ,.°viriii.3 for subsequent approval Final acceptance i s1 !h �1...ict to field test and inspection b„ The Tukwila hire Pi ev,antlon Bureau. mate: 3- 3 By: /,5 SHEET INDEX NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement -of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 205-575-4407 and give this Fire Permit No. and exact a'ddie:ss for shut- down or restoration approval. WISE SCHEDULE A\J CO 3 U IT FILL C HATT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT ❑F ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIKUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHOR TY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN FULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDLIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 NORDSTROM 3 LEVELS 171,275sf S ESl tLKSJ N'AEDENROOKS rl SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM E FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N /A N/A NOT APPLICABLE N/A N/A N/A N /A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND crvnvn nvt:v rcrory r:"v r .c AANR su45..As3 CH,CH 5 P VERl.'ON WPE! CSS MADE Irl WASN:NCION OuncNA: UNIVERSITY EAU, WORKS 1 SWATM I..Ir%E.GJ: RtS o ff macys L.EVE.L. 25(:.40 /Et �o;v; ;Irsi ARkrt;V,UPIE UNpUE s sraPRu:..s i PAIJOCRA rt IL IUL (05",.):9 MOR BEAUTY 1387 / SPACE #360 o ru uLCHC m,. :Ours I FO .I.pT AP. 1.1% SHOP 4 ,INCER DON _.___._-..i 0 5011 tAa nIE RnH'r REE r r,5ui n? 1-4„:22.Lr NTH Y S'O=E RECAAA F111Y ASS rI o. CC 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 03/22/13 2aaaaa JCPenney PAID MAR 2 5 2013 TUKWILA FIRE If co Z*co O Ucv, o0 Sao Et o'o < 2z 0 ccZ U) W Q W � O� co T uJ (1) (it /SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 03/22/1 3 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved ..,JOB NUMBER: 1 SHEET ,\ FA -01 J THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60NZ — DEDICATED EIAERGENCY NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRDOUCT DOCIRIEIITADON. 'CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC ISOLATE F GRDIRJDINGD TO NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE - FROM XLS CONTROL PANEL (+ DR PREVIOUS ADDRESSABLE DEVICE O 0 GROUND'' 4 O O 0 HTRI—R 0 ©s MIT e1 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 O C -CABLE C -CABLE O 0 GRD N LL a 0 PAD -3 00 NPUT INPUT TROUBLE NAM NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 0 0 0 0 0 0 0 0 3.6k EOL (-) (+) SPARE SPARE � SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) .1 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPUFPLR RED (JACKET) 'CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 r® ®0 GROUND L-. HTRI—R I le4 J 0 0 (+)>T0 NEXT DEVICE OR (-) > STOP IF LAST DEVICE ---> DRY CONTACTS TO VAV �► FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL TO NEXT ADDRESSABLE DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE HOOD EOL GROUND 0 m CLI (Y) 0 HTRI—S STATUS LEL 0 co 0 0 m NOT USED 0 O HOOD MONITOR MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL H❑RN/STROBE ❑R STROBE ONLY + u HORN/STROBE OR STROBE ONLY HORN/STROBE ❑R STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERATIJRE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) SMOKE DETECTOR TO NEXT ADDRESSABLE (+) DEVICE JIRING DETAIL 00 0 o° HCEILI❑RN SNG TR❑BE STROBE ONLY SUPPORT BRIDGE 4" SQUARE DEEP BOX DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL CJ JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT O O O O TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR - ,cD f SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE M N M 0 (1.) J UJ 0 0 c M Z O U � O E ocnz Q -0 0 L• TJ V 2 nu) 0 Ca CC 2 z O t Q � w152 rrEc Oz Cr co J 0 -GALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE:03/22/13 BACKROUND PLAN PROVIDED BY: \OB NUMBER: Proprietary and Confidential, Copyright; 2010 by Guardian Security Systems, Inc. All Rights Reserved i SHEET FA -02 i Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HTRI-S 0.0096 0 0.0021 0.000 AD2-P 0.0635 0.0635 0.064 0.000 HTR -R 1 0.0096 0.0096 0.021 0.021 0.0731 Amps 0.021 Amps STING:S1EME xtehriler Pa n01:„ on Curient Load: ndby ala Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW @15CD 13 0.0875 ZH-MC-CW @30CD 9 0.131 ZH-MC-CW @75CD 2 0.222 ZH-MC-CW @95CD 0.292 ZH-HMC-CW @135CD 0.371 ZR -MC -CW @15CD 5 0.069 0.345 ZR -MC -W @15CD 12 0.064 0.768 0.03 Amps 1.143 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.143 Amps For 5 Minutes= 0.096 Amp -hours 25% De rating= 1.020 Amp -hours Total System Current Load: 1.020 Amp -hours Pair tt be Used:' 12V0 IN Notification Appliance Circuit Detail 'PROJECT: ` MOR BEAUTY Panel: EXISTING PAD -3 BPS (BACK OF HOUSE) Date: j March 22, 2013 Wire Resistance 2.58 CURRENT TOTAL=1236.00 1 JZH-MC-CW @15cd C @30cd ZH-MC-CW @75cd ZH-MC-CW @95cd ,72H -MC -CW @135cd ZR -MC -W @l5cd 3 1 DEVICES 87 j 131. 222 292 3711 64 TOTAL mA= ;Total Wire Resistance (R ) Total Device Load, Amps (I) 1Voltage Drop ( E ) EOL Voltage 87! 13 0I 01 64 . 2361, 14 220 23.73 1(WL*2)*(R/ft) (Total Cct toady (E=l*R) 236: 1.14 tl 24' 0.271 23.73 SYSTEM CALCULATIONS 'y '4 O. t7 0 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS TO NEAREST EXISTING POWER SUPPLY c' (BACK OF HOUSE) TO NEAREST EXISTING �> DATA LOOP EOL S1 J s,sI (J -BOX LOCATED AT HALLWAY S1-1 INSTALL STROBE CIRCUIT EOL 15cd RESISTOR INSIDE J -BOX) S1-2 S1-3 15cd 30cd FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. IREV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 03/22/13 2aaaaa Z O U co �rn �tnz Q JO QO CLQ cf.) Crew' O `5 <1- w Er_ n on co T w w 0 L (1) 0 I— 0 w F - (i) >- U) CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 03/22/13 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM \0B NUMBER: Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -03 TO NEAREST EXISTING POWER SUPPLY (BACK OF HOUSE) TO NEAREST EXISTING DATA LOOP E/.ISTiN( EXIT CORRIDOR s6 EOL S1 D6 a TIT �I I II ii 11 1 11 ri. y�L I EN I 1 i 111 i!I ill 11-1 !ll ill i.11 111 i HI 11 II Ir 1i: 1�L I 1 111 1I ILiI II 11 ;l 1.11 111 11 ,10 1. NOTA FULL WALL [1io2 1 EXIT 11� iN 1! I{I 11 li I �-1 111 I t� i' ii1 1,1 I .. it 1. it r. ri i1 ii -1;] 111. 1- it l r1 1 I� !i11l t 111 11-] ii ;.. .111 LJ 'IL -1 I 1 l ; it111 �j. 11 11 i1 MAL. OCNCOLIRSE 12,7 L/ 10!' y.,1I',LES'2LCO . HT -R S1-'I-- 15cd / FX` TIN!s FI OCRING AND FINI;SNE•S TO REMAIN' E ;1:1 -1 1 r r; �h= i 11 111 ir. 4 ~C :: i/ (1c4 II{[1 1 EXISTING SINK TO REMA I\ \ 1 -1;h li • li 11 iii 1-11 ill I- ij ii I i -aI 1 S1:-2- --- 15cd _✓_4..1 RE,S"RC,OM / II II FLOOR PLAN - FIRE ALARM EXISTING: STORE FRONT TO REMAIN, NEWFINISHES PER ELEVATIONS SHEET EXISTING. CERAMIC TILE FLOOR TO REMAIN. ^' �_ ,1N. •- NEW LVf-1. FLOORING SEE FINIS;-! SCHEDULE SHEET 46.1 I^,JACENT TENANT SPACE PRETZEL ';/ASTER - EXISTING WALLS TO REMAIN, PATCH. AND REPAIR FOR NEW P: DINT FINISH. EXIST/NG ADA COMPLIANT RESTROOM AND FI'/.TURES TO REMAIN. NO NEW WORK. EXISTING EX1TACCE. S AND SIGNAGE 0 REMAIN, T YF TO NEAREST EXISTING POWER SUPPLY (BACK OF HOUSE) s6 1 EOL J FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. EXISTING ACT AND GWB CEILINGS TO REMAIN THROUGHOUT. FAINT CEILINGS AND GWE, SOFFITS FT -I SEE FINISH SCHEDULE SHEET .4.6.1 i 11 6"AFF 4...... ®EX S1-3 / / / / / / / / r� (7) — (F) 30cd 1 , IO I6 "AFF �'-/ 1r/.1 D 's, \ -.I. 15cd 1 StXISTING 2X,4 FIXTURE ----- TO NEAREST D TO REMAIN,T1 P EXISTING DATA b LOOP REFLECTED CEILING PLAN - FIRE ALARM I" I .\1: ,,1•; , 1 (ry ,-'/:‘,7111\:/. it r I:'t •. I\ ti,•, 17, �,\..,. 1 - r l'.c ,S,L.:(I,FS. IN N�} 1 r)f 0-5 z z Si cc z 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS DATE 03/22/13 aaaaa O M co O U T P �c `C mit- < 2 <2W CO cn 1- Q cc w' O � c) W�� Lc Q1.— co SCALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 03/22/13 BACKROUND PLAN PROVIDED BY: .0B NUMBER: 1 SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1387 SOUTHCENTER MALL ASSOCIATED PERMITS 13-F-071 16-S-098 ITZMAN SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** O.' �% /)King Co. Assessor's Tax No.: (2(i�`J OO I 0 Site Address: 1 mais Suite Number: CC 3O Floor: Tenant Name: ° I t () f / �� �� — ci fJ2 "(Q New Tenant? - Yes ❑ - No Property Owner's Name: Y\1 0 Mailing Address: City CONTACT PERSON -if there are questions about the submittal. Name: KARINA VELIZ Day Telephone: 206-734-6276 x229 Company Name: GUARDIAN SECURITY SYSTEMS. INC Mailing Address: 1743 - 1ST AVE S SEATTLE . WA 98134 City State Zip E-mail Address: kveliz@guard iansecur ity. corn Fax Number: 206-341-9928 State Zip Valuation of Project (contractor's bid price): $ '-5-6() Scope of Work (please provide detailed information): I�GI vtX(5k ( n pcvAa - 4i13 L1 cLvv cu PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER OR AUTHORjED AGENT: Signature: Print Name: Plan Permit App.doc k Date: ' 22 C\V � v e t Day Telephone: 1)-(A) "I• v 2.6( 5/1 4/1 0 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: MOR Beauty 1387 Southcenter Mall Permit No.: 16-S-098 Date: May 11, 2016 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. Without CofIirlteril`S As Note!? Per The Ati. rciii:;, letter These plans have 'leen r ev Ieuvea by 1•he 'Tukwila Fire Prevention Bureau ,cr: .::orlforrnanc. with current City st-ndards. iuoje t rs • errors and orni sions whid.. ;t,-,otnortzr-: ,,,olauons of adopted sV:inciaros ano f,r',';; •:,r yr' .; rho rnsoonsibriity for the v'th Cif.? designer, • •r1sq.Ins tr1 Ihe;.rr, or?)viiinys after c1dequacy of de"1r1 /additions., ielc .to -. this dateMOvoid t? . .-C,epcar,c€ and vdili require a tesubrnitl C%i Iii t,,: ti l: �.'` •.`Vi ngs fry 5(.10F:egl.lent approval. Final accepi'anc(7 yield test ano inspection by The Tukwila Fire P.evehr. _:,:- furreeau. Date: � 11- /L =•,r: / V "' ( r f.R ' DEPARTMENT and »5v,, thi, ';i7h•.' i'a d mit: No. and caceict a,dd tss for shut- down or r storMCn approval). • 0 EXISTING CHOW KING NEW CEILING/SOFFIT/BULKHEAD - SIMILAR TO PIRSHOKY'S (NEXT DOOR) MOR BEAUTY TENANT SPACE EXISTING PIROSHKY'S * FIELD VERIFY ALL DIMENSIONS 25'-7" ALIGN 01 01 ieo EXIST. EXIT DOORS TO REMAIN REFLECTED CEILING PLAN SCALE: 1/4" = 1'-O" Design per NFPA 13, Ordinary Hazard Group 2 / Retail All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilins, or any other means All heads to be at least 6' apart ;0 14 ® 4 – Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 TOTAL - 4 •• FlexHead Sprinkler Drop . OlMI t, (,'`=Rt;54, Cofrugated stainless steel hose with stainless steel brat `:..;:; %available In 2', 3',4',5' & 6' legnths •. • Multi -Port Bracket • Adjustable Hub • .1 Ftl<EAD 1 ousraies ' • Flexhe6c1 omme'rcial Ceiling Unit T -Bar Ceiling Installation . Model #2024,2036,2048,2060,2072 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS MALL KEY PLAN a 1- L.evei 1 1� Andover Park W. g Family Parking LANDLOI WORK = MOR BEAUTY •i ; • ®O fco - a W a W = i' NOTON STATE OERTIF • TE OF COMPETENCY FIRE PROTEC ON SPRINKLER SYSTEMS John J. Abel 9760-06914volG 3 F • NOT TO SCALE CROWN FIRE. PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 MOR Beauty 1387 Southcenter Mall Space # C-21 Tukwila, WA 98188 TI DATE: • o5., `(a DRAWN: 0 SCALE: 119 16 I Expires 12131118 PAID iq10 21115 KW1LA FIRE -2/Yc) Iiov ..... ....................................................................... ...44; '.:.. -- - • Fa................... :i.it!•.....••• ..::. ::— l• •:::.: :�. ��:•::.:•::�:��:�:�:•:• ?i sir?:-}i:•::i{i:- .... : ..... EXIST. ALIGN NEW LIGHT FIXTURE W/ — EXISTING STOREFRONT FIXTURES, TYP. OF 6 7'-8 1/2" = 12" T-113/4" STOREFRONT/DOOR TO REMAIN / / 1\ EXIST. EXIT DOORS TO REMAIN REFLECTED CEILING PLAN SCALE: 1/4" = 1'-O" Design per NFPA 13, Ordinary Hazard Group 2 / Retail All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilins, or any other means All heads to be at least 6' apart ;0 14 ® 4 – Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 TOTAL - 4 •• FlexHead Sprinkler Drop . OlMI t, (,'`=Rt;54, Cofrugated stainless steel hose with stainless steel brat `:..;:; %available In 2', 3',4',5' & 6' legnths •. • Multi -Port Bracket • Adjustable Hub • .1 Ftl<EAD 1 ousraies ' • Flexhe6c1 omme'rcial Ceiling Unit T -Bar Ceiling Installation . Model #2024,2036,2048,2060,2072 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS MALL KEY PLAN a 1- L.evei 1 1� Andover Park W. g Family Parking LANDLOI WORK = MOR BEAUTY •i ; • ®O fco - a W a W = i' NOTON STATE OERTIF • TE OF COMPETENCY FIRE PROTEC ON SPRINKLER SYSTEMS John J. Abel 9760-06914volG 3 F • NOT TO SCALE CROWN FIRE. PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 MOR Beauty 1387 Southcenter Mall Space # C-21 Tukwila, WA 98188 TI DATE: • o5., `(a DRAWN: 0 SCALE: 119 16 I Expires 12131118 PAID iq10 21115 KW1LA FIRE -2/Yc) Iiov SITE LOCATION Site Address: Tenant Name: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** GS7 Sou-i-liCC*r' Y1a('Reaofi/, Property Owner's Name: .eS* \-E'�C1, rn5%Yl\ (-rh9 King Co. Assessor's Tax No.: Suite Number: C—UII , Floor: Mailing Address: New Tenant? la -r_ Yes ❑ - No CONTACT PERSON -if there are questions about the submittal. Name: City Company Name: CA'Q\j)Y\ 1 r.Q FrWC- lc%), )Ylc State Zip Day Telephone: _?'Z 9 /' 766 Mailing.Address: CV gox / JL3 ynJll Cr-e6k; City E-mail Address: 1 411 a' 0 State Zip Fax Number: 112 — , RI 's(44 S" Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $_�f jj Scope of Work (please provide detailed information): AM, (Li) )7'aels PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in • writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. z . • I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW J ER OR AUTHORIZED AGENT: awca-P deJsk21;R as47) Signature: Print Name: Plan Permit App.doc Date: 5'5 'AO Day Telephone: 1-.0-4181•7401 1/2/13 TFD FP Form 8 Bulletin 034 Rev. C Model G5-80, Model G5-56, ReliableModel G5-42, Model G5-28 Quick Response Concealed Automatic Sprinkler 'uo iku. tt ,d v� r, �.nt,✓ sr ,,:a.,.,r a�, r�,u � .r..�.��HL3 �s a��,rt�a„�4 x C`�sn,J :?. l be it„t'i si rti, ..�� UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4" (19mm) Adjustment Features 1. Cover plate attachment (Plain or Perforated) with 3/4" (19mm) assembly adjustment. 2. Smooth aesthetic ceiling profile. 3. Factory installed protective cap. 4. Available in Chrome and White as Standard Finish- es. Special Application Finishes are also available. 5. Ordinary and Intermediate temperature rating. For additional Sprinklers refer to Bulletin 154 for Technical Specification and Approvals Approvals & Listings 1. Underwriters Laboratories Inc. and cULus - Quick Response • G5-80, G5-56 - Light Hazard and Ordinary Hazard Occupancies • G5-42 - Light Hazard Occupancies • G5-28 - Light Hazard Occupancies 2. Factory Mutual Research Corp. (FM) - Standard Response (See Page 3) • See the most recent FM Global Property Loss Prevention Data Sheets for installation and use guidelines. 3. Loss Prevention Council (LPCB, UK) - Standard Response • G5-56 - Light Hazard and Ordinary Hazard Occupancies 4. VdS Schadenverhutung GmbH - Standard Response 5. EC -Certificate of Conformity 0832 -CPD -2062 U.S. Patent number 6,554,077. Application The Reliable Model G5-80, G5-56, G5-42 and G5-28 are the most versatile quick response concealed sprinklers avail- able. It provides the best form of fire protection while offering an attractive appearance and 3/4" (19mm) of cover adjust- ment for ease of installation. The small diameter cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an au- tomatic sprinkler system. Plain Cover Plate Perforated Cover Plate The Model G5-80, G5-56, G5-42 and G5-28 are designed for use where aesthetic appearance is important. Offices, hos- pitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13. FM Approves the G5-56 and the G5-28 sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. The Reliable Automatic Sprinkler Co., Inc., 103 Product Description The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides 3/4" (19mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. Fairview Park Drive, Elmsford, New York 10523 5 Installation Do not install the G5-80, G5-56, G5-42 and G5-28 in ceilings which have positive pressure in the space above. • Cut a 25/" inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/ CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G5-80, G5-56, G5-42 and G5-28 should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. Concealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Ordering Information 1. Sprinkler Model 2. Nominal Orifice 3. Flat Cover Plate Plain or Perforated 4. Flat Cover Plate Assembly Finish 5. Inlet Type Cover Plate Finishest'> Standard Finishes Chrome White Paint Special Application Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome 2. 1) Other finishes and colors are available on special order, Consult factory for details. Coverplate custom paint is semi -gloss, unless specified otherwise. e) For the perforated style cover - plate, consult factory for avail- ability on these and other cus- tom finishes. Model FC Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Maximum Working Pressure 175 psi (12 bar) 100% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating Classification Sprinkler Cover Plate Max. Ambient Temp. Ordinary 165°F/74°C 135°F/57°C 100°F/38°C Intermediate 212°F/100°C 165°F/74°C 150°F/66°C Technical Data Sprinkler Model Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor Thread Approvals Sprinkler Identification (SIN) US Metric G5-80 Non Adjustable 3/a" (19mm) 17/32" (15mm) 8.0 115 3/a" NPT (R3A) 1 RA3412 G5-56 Non Adjustable 3/4" (19mm) 1/2" (15mm) 5.6 80 1/2" NPT (R1/2) 1,2,3,4,5 RA3415 G5-42 Non Adjustable 3/a" (19mm) 1/16" (10mm) 4.2 60 1" NPT (R1/2) 1 RA3413 G5-28 Non Adjustable 3/a" (19mm) 3/" (10mm) 2.8 40 1/2" NPT (R1/2) 1,2 RA3411 For VdS Approval, temperature rating sprinkler 165°F/74°c and cover plate 135°F/57°C only! 1" x 1/2" REDUCING TEE OR ELBOW tT I II 1" x 3/4" REDUCING TEE ORRELBOW G5-80 ONLY 2" [58.42mm] DIA CUP 23" [66.55mm3 HOLE IN CEILING 1 2-1/4" [50.8mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING i" [19.O5mm] MAX. _ COVER ADJUSTMENT FLAT COVER PLATE ASSEMBLY OJ4F001A " [84.21 mm] DIA. SPRINKLER th" [4.96mm] COVER PLATE: 3/4 " [ 19.05mm 7 ADJUSTMENT Notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS x 1/2' REDUCING TEE OR ELBOW - II I II IT 1 11, IL ill -- r RELIABLE P/N 699999190011 }' X' BRASS NIPPLE EXT.\ I 211' (58.42mm] DIA CUP CEILING Val 23' [66.55mm] HOLE IN CEILING //////// 3-1/16• [77.72mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 2-1/4' [50.8mm] MAX. FACE OF NIPPLE EXT. TO FACE OF CEILING DIMENSION i' [19.05mmJ MAX. — COVER ADJUSTMENT FLAT COVER PLATE ASSEMBLY ONFVD2 SPRINKLER 37.1" [84.21 mm] DIA. ti' [4.96mm] COVER PLATE: 3/4" [19.05mm] ADJUSTMENT NOTE: 1. Testing has shown that use of a "nipple extension" will not affect the listing of the sprinkler. 2. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, "which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems". 3. Do not exceed 8-18 ft -lbs of torque during installation. 3. I. eliable.e.For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address rit tali Recycled Paper Revision lines indicate updated or new data, EG. Printed in U.S.A. 11(13 P/N 9999970421 DDITION N SHEET \UV 3E SHEET TITL FA -01 SYSTEV \FOPVATIO\ FA -02 TYPICAL WHI\ G A\3 IVOU\ TI\ G DETAILS FA -03 SYST V CALCULATIO\S A\ D SI\GLE LI\E DIAGRAM FA -04 FHE ALA V SYSTEV PLA\ likrithou+. (,mono .-It5 Ash1t.,,i: -2 i feed p Per The Att ached Letter plans have. been t Ceviev,wcd by The Tukwila Fire . :: mon Bur";z:•i iron conformance 'F Eri; current City •a ; .Suo jecterrors and �,;�� CtS. J1,a::. t'i•...., , ,. is ! ,..v to violations of adopted ?'.,Fircis and ' rill ir'r,'. ces, The responsibility for the ?uuary of d: sir'!i i totally with the designer. i,ti c 1:•, : r'r i `vi{sIors to t;hese drawings after date will void ::rill,"•, .': 'pr'i'ce and will require a resubmittal of reviri r: <i; I ,.°viriii.3 for subsequent approval Final acceptance i s1 !h �1...ict to field test and inspection b„ The Tukwila hire Pi ev,antlon Bureau. mate: 3- 3 By: /,5 SHEET INDEX NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement -of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 205-575-4407 and give this Fire Permit No. and exact a'ddie:ss for shut- down or restoration approval. WISE SCHEDULE A\J CO 3 U IT FILL C HATT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT ❑F ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIKUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHOR TY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN FULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDLIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 NORDSTROM 3 LEVELS 171,275sf S ESl tLKSJ N'AEDENROOKS rl SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM E FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N /A N/A NOT APPLICABLE N/A N/A N/A N /A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND crvnvn nvt:v rcrory r:"v r .c AANR su45..As3 CH,CH 5 P VERl.'ON WPE! CSS MADE Irl WASN:NCION OuncNA: UNIVERSITY EAU, WORKS 1 SWATM I..Ir%E.GJ: RtS o ff macys L.EVE.L. 25(:.40 /Et �o;v; ;Irsi ARkrt;V,UPIE UNpUE s sraPRu:..s i PAIJOCRA rt IL IUL (05",.):9 MOR BEAUTY 1387 / SPACE #360 o ru uLCHC m,. :Ours I FO .I.pT AP. 1.1% SHOP 4 ,INCER DON _.___._-..i 0 5011 tAa nIE RnH'r REE r r,5ui n? 1-4„:22.Lr NTH Y S'O=E RECAAA F111Y ASS rI o. CC 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 03/22/13 2aaaaa JCPenney PAID MAR 2 5 2013 TUKWILA FIRE If co Z*co O Ucv, o0 Sao Et o'o < 2z 0 ccZ U) W Q W � O� co T uJ (1) (it /SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 03/22/1 3 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved ..,JOB NUMBER: 1 SHEET ,\ FA -01 J THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60NZ — DEDICATED EIAERGENCY NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRDOUCT DOCIRIEIITADON. 'CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC ISOLATE F GRDIRJDINGD TO NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE - FROM XLS CONTROL PANEL (+ DR PREVIOUS ADDRESSABLE DEVICE O 0 GROUND'' 4 O O 0 HTRI—R 0 ©s MIT e1 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 O C -CABLE C -CABLE O 0 GRD N LL a 0 PAD -3 00 NPUT INPUT TROUBLE NAM NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 0 0 0 0 0 0 0 0 3.6k EOL (-) (+) SPARE SPARE � SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) .1 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPUFPLR RED (JACKET) 'CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 r® ®0 GROUND L-. HTRI—R I le4 J 0 0 (+)>T0 NEXT DEVICE OR (-) > STOP IF LAST DEVICE ---> DRY CONTACTS TO VAV �► FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL TO NEXT ADDRESSABLE DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE HOOD EOL GROUND 0 m CLI (Y) 0 HTRI—S STATUS LEL 0 co 0 0 m NOT USED 0 O HOOD MONITOR MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL H❑RN/STROBE ❑R STROBE ONLY + u HORN/STROBE OR STROBE ONLY HORN/STROBE ❑R STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERATIJRE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) SMOKE DETECTOR TO NEXT ADDRESSABLE (+) DEVICE JIRING DETAIL 00 0 o° HCEILI❑RN SNG TR❑BE STROBE ONLY SUPPORT BRIDGE 4" SQUARE DEEP BOX DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL CJ JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT O O O O TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR - ,cD f SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE M N M 0 (1.) J UJ 0 0 c M Z O U � O E ocnz Q -0 0 L• TJ V 2 nu) 0 Ca CC 2 z O t Q � w152 rrEc Oz Cr co J 0 -GALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE:03/22/13 BACKROUND PLAN PROVIDED BY: \OB NUMBER: Proprietary and Confidential, Copyright; 2010 by Guardian Security Systems, Inc. All Rights Reserved i SHEET FA -02 i Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HTRI-S 0.0096 0 0.0021 0.000 AD2-P 0.0635 0.0635 0.064 0.000 HTR -R 1 0.0096 0.0096 0.021 0.021 0.0731 Amps 0.021 Amps STING:S1EME xtehriler Pa n01:„ on Curient Load: ndby ala Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW @15CD 13 0.0875 ZH-MC-CW @30CD 9 0.131 ZH-MC-CW @75CD 2 0.222 ZH-MC-CW @95CD 0.292 ZH-HMC-CW @135CD 0.371 ZR -MC -CW @15CD 5 0.069 0.345 ZR -MC -W @15CD 12 0.064 0.768 0.03 Amps 1.143 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.143 Amps For 5 Minutes= 0.096 Amp -hours 25% De rating= 1.020 Amp -hours Total System Current Load: 1.020 Amp -hours Pair tt be Used:' 12V0 IN Notification Appliance Circuit Detail 'PROJECT: ` MOR BEAUTY Panel: EXISTING PAD -3 BPS (BACK OF HOUSE) Date: j March 22, 2013 Wire Resistance 2.58 CURRENT TOTAL=1236.00 1 JZH-MC-CW @15cd C @30cd ZH-MC-CW @75cd ZH-MC-CW @95cd ,72H -MC -CW @135cd ZR -MC -W @l5cd 3 1 DEVICES 87 j 131. 222 292 3711 64 TOTAL mA= ;Total Wire Resistance (R ) Total Device Load, Amps (I) 1Voltage Drop ( E ) EOL Voltage 87! 13 0I 01 64 . 2361, 14 220 23.73 1(WL*2)*(R/ft) (Total Cct toady (E=l*R) 236: 1.14 tl 24' 0.271 23.73 SYSTEM CALCULATIONS 'y '4 O. t7 0 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS TO NEAREST EXISTING POWER SUPPLY c' (BACK OF HOUSE) TO NEAREST EXISTING �> DATA LOOP EOL S1 J s,sI (J -BOX LOCATED AT HALLWAY S1-1 INSTALL STROBE CIRCUIT EOL 15cd RESISTOR INSIDE J -BOX) S1-2 S1-3 15cd 30cd FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. IREV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 03/22/13 2aaaaa Z O U co �rn �tnz Q JO QO CLQ cf.) Crew' O `5 <1- w Er_ n on co T w w 0 L (1) 0 I— 0 w F - (i) >- U) CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 03/22/13 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM \0B NUMBER: Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -03 TO NEAREST EXISTING POWER SUPPLY (BACK OF HOUSE) TO NEAREST EXISTING DATA LOOP E/.ISTiN( EXIT CORRIDOR s6 EOL S1 D6 a TIT �I I II ii 11 1 11 ri. y�L I EN I 1 i 111 i!I ill 11-1 !ll ill i.11 111 i HI 11 II Ir 1i: 1�L I 1 111 1I ILiI II 11 ;l 1.11 111 11 ,10 1. NOTA FULL WALL [1io2 1 EXIT 11� iN 1! I{I 11 li I �-1 111 I t� i' ii1 1,1 I .. it 1. it r. ri i1 ii -1;] 111. 1- it l r1 1 I� !i11l t 111 11-] ii ;.. .111 LJ 'IL -1 I 1 l ; it111 �j. 11 11 i1 MAL. OCNCOLIRSE 12,7 L/ 10!' y.,1I',LES'2LCO . HT -R S1-'I-- 15cd / FX` TIN!s FI OCRING AND FINI;SNE•S TO REMAIN' E ;1:1 -1 1 r r; �h= i 11 111 ir. 4 ~C :: i/ (1c4 II{[1 1 EXISTING SINK TO REMA I\ \ 1 -1;h li • li 11 iii 1-11 ill I- ij ii I i -aI 1 S1:-2- --- 15cd _✓_4..1 RE,S"RC,OM / II II FLOOR PLAN - FIRE ALARM EXISTING: STORE FRONT TO REMAIN, NEWFINISHES PER ELEVATIONS SHEET EXISTING. CERAMIC TILE FLOOR TO REMAIN. ^' �_ ,1N. •- NEW LVf-1. FLOORING SEE FINIS;-! SCHEDULE SHEET 46.1 I^,JACENT TENANT SPACE PRETZEL ';/ASTER - EXISTING WALLS TO REMAIN, PATCH. AND REPAIR FOR NEW P: DINT FINISH. EXIST/NG ADA COMPLIANT RESTROOM AND FI'/.TURES TO REMAIN. NO NEW WORK. EXISTING EX1TACCE. S AND SIGNAGE 0 REMAIN, T YF TO NEAREST EXISTING POWER SUPPLY (BACK OF HOUSE) s6 1 EOL J FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. EXISTING ACT AND GWB CEILINGS TO REMAIN THROUGHOUT. FAINT CEILINGS AND GWE, SOFFITS FT -I SEE FINISH SCHEDULE SHEET .4.6.1 i 11 6"AFF 4...... ®EX S1-3 / / / / / / / / r� (7) — (F) 30cd 1 , IO I6 "AFF �'-/ 1r/.1 D 's, \ -.I. 15cd 1 StXISTING 2X,4 FIXTURE ----- TO NEAREST D TO REMAIN,T1 P EXISTING DATA b LOOP REFLECTED CEILING PLAN - FIRE ALARM I" I .\1: ,,1•; , 1 (ry ,-'/:‘,7111\:/. it r I:'t •. I\ ti,•, 17, �,\..,. 1 - r l'.c ,S,L.:(I,FS. IN N�} 1 r)f 0-5 z z Si cc z 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS DATE 03/22/13 aaaaa O M co O U T P �c `C mit- < 2 <2W CO cn 1- Q cc w' O � c) W�� Lc Q1.— co SCALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 03/22/13 BACKROUND PLAN PROVIDED BY: .0B NUMBER: 1 SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved