Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 1150 SOUTHCENTER MALL - MOCTEZUMA / RACHA THAI KITCHEN - PERMITS AND PLANS
1150 SOUTHCENTER MALL ASSOCIATED PERMITS 14-F-240 08-F-189 14-S-242 08-S-078 14-H-274 08-H-192 .ate SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 1150 Southcenter Mall Tenant Name: Moctezuma's Restaurant New Tenant? - Yes Ej - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip King Co. Assessor's Tax No.: 9202470010 Suite Number: Floor: CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address- 1743 First Ave South, Seattle, WA 98134 E-mail Address: kveliz@guardiansecurity.com City State Zip Fax Number: 206.628.4990 Total number of new/relocated devices or sprinkler heads: 15 Valuation of Project (contractor's bid price): $ 5000 Scope of Work (please provide detailed information): Adding 15 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO IZED AGENT: (r�� % L Signature: Date: \ V 1. / J —1 Print Name: Karina Veiiz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: \ SnokbrenAef MI Suite Number: Floor: Tenant Name: m c*-e_ap1Y V v A-\- New Tenant? Property Owner's Name: '\- e\N NY\no ; m,� -- CYIa-P Mailing Address: Jl �i��� IAA ► . City - Yes ❑ - No CONTACT PERSON -if there are questions about the submittal. Name: 1( a, Company Name: p Q Mailing Address: \ x W\' 2-' 1J \\\ 1 Cce-e\ ( 1 � CEJ E-mail Address: 3.(5C-Accverinto n roc -1--) Fax Number: 2 -S -14k) ''Zt(19(S--- State ip Day Telephone: 6n9 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $,0IM_ Scope of Work (please provide detailed information): NAN v\e_Cta Fele (2) hds PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. \Z Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ' WNER OR AUTHO ; ED AGENT: 'jj Signature: AI '1141 -' fil i1 k Print Name: C )eSS I a 3O) / 1 C5r) Plan Permit App.doc Date: 0)2 4 Day Telephone: ti2f ' L O 1 7(0(09 1/2/13 TFD FP Form 8 FILE COPY FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Racha Thai 1150 Southcenter Mall Permit No.: 08-S-078 Date: February 1, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath ail obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. All references are NFPA 13, 2007 Edition. J J 11 March 2008 Martin Sokulski Westem States Fire Protection 7102 180t Ave NE, Suite A-105 Redmond, WA 98052 RE: Westfield Mall — Racha Thai Kitchen (Suite #1150) Independent Third Party Review — Fire Sprinkler System Dear Martin: Tuazon Engineering, PLLC 4322 NE r Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax wwi.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. It is noted that the sprinkler system modifications shown are to Zone T5 fed from the East Riser Room. The following was reviewed: • Fire Sprinkler Drawings — Sheet FP1 dated 3/10/08 • Hydraulic Calculations dated 3/10/08 The documents were reviewed for compliance with the 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. The hydraulic calculations and sprinkler spacing for the Seating Area are for Light Hazard occupancy. The minimum design density should be Ordinary Hazard Group I (0.15 GPM/SF) and maximum sprinkler spacing should be 130 SF per City of Tukwila Ordinance 2050, Section 16.42.070.C. 2. Include the sprinkler identification numbers (SIN) in the sprinkler legend on Sheets FP1 and FP2. 3. Include product data with the submittal to the City of Tukwila. A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or eric@tuazon.com with any questions regarding this review. Respectfully, TUAZON ENGINEERING PLLC czuz p Eric P. Tuazon, PE Fire Protection Engineer C Korryrry FIa:12008 R9%1a12CC81d Westem Shales. Racha Thal, Ima08taxm sp.**,revery doc m FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Moctezuma's Restaurant 1150 Southcenter Mall Permit No.: 14-S-242 Date: October 29, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). s • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Moctezuma Restaurant 1150 Southcenter Mall Permit No.: 14-H-274 Date: December 2, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Nozzle heights above appliances to be per manufacturers installation guidelines. • Fryers shall be installed with at least a 16 inch space between the fryer and surface flames from adjacent cooking equipment or a minimum 8 inch high steel or tempered glass baffle plate shall be installed between the appliances. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust system whenever cooking operations occur. The activation of the exhaust system shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. • A minimum 110 candela horn/strobe shall be installed above the kitchen hood suppression system manual pull station at a height of 80 inches above the floor. • A separate fire alarm permit from the Tukwila Fire Department is required for all fire alarm work. 2~ ,3c e‘// • The suppression system manual pull station shall be located no closer than 10 ft. and no farther than 20 ft. from the cooking equipment and be placed at a height of 42 to 48 inches above the floor. • The inside lower edge of the hood shall overhang or extend a horizontal distance of not less than 6 inches beyond the edge of the top horizontal surface of the appliance on all open sides. The vertical distance between the front lower lip of the hood and such surface shall not exceed 4 feet. 4 • If cooking appliances are wheeled, the appliance wheels shall be set in tracks permanently mounted to the floor to ensure appliance is returned to original location if moved for cleaning or maintenance. Job Number: KS0255 Report Description: Racha Thai Kitchen Zone T5 Job Job Number KS0255 Design Engineer Martin Sokulski Job Name Racha Thai Kitchen State Certification/License Number WESTESF136QF Address 1 1150 Southcenter Mall AHJ City of Tukwila Address 2 Job Site Southcenter Mall City Tukwila State WA I Zip Code 98188 Drawing Name FP -1 Rachal5-2.cad System Remote Area(s) Most Demanding Sprinkler Data 5.6 K -Factor 26.00 at 21.556 Occupancy Ordinary Group II Hose Allowance At Source 250.00 Density 0.20gpm/ft2 Area of Application 900.0Oft2 (Actual 911.15ft2) Additional Hose Node Supplies Flow(gpm) • Number Of Sprinklers Calculated 10 Coverage Per Sprinkler 130.00ft2 4ploosOmmCei44 ieteCertik4 or t �° /ai 0 r � Total Hose Streams 250.00 System Flow Demand 281.12 Total Water Required (Including Hose Allowance) 531.12 i �:� r `n/401111:4....2 Maximum Pressure Unbalance In Loops 0.000 414Poosh Maximum Velocity Above Ground 16.91 between nodes 55 and 58 1 Maximum Velocity Under Ground 1.06 between nodes 1 and 364 Volume capacity of Wet Pipes 2301.27ga1 Volume capacity of Dry Pipes 1.24ft' Supplies Node Hose Flow (gpm) Static (psi) Residual (psi) Flow (gpm) Available Total Demand (psi) (gpm) Required (psi) Safety Margin (psi) 1 250.00 140.000 1 20.000 1 10900.00 139.552 j 531.12 68.398 71.154 Contractor Contractor Number I KS0255 I Contact Name i Martin Sokulski I Contact Title PM Contractor Name Western States Fire Protection Phone i 425.881.0100 ; Extension Address 1 7108 180th Ave NE ' FAX ' 425.881.3030 Address 2 ' E-mail martin.sokulski@wsfp.us City Redmond State Zip WA ' Code Web -Ste 98052 L, ©M.E.P.CAD, Inc. Mtj AutoSPRINK® VR5 v5.2.6 02/27/2008 8:14:18AM Page 1 Summary Of Outflowing Devices Job Number: KSO255 Report Description: Racha Thai Kitchen Zone T5 6_k, © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 02/27/2008 8:14:19AM Page 2 Device Actual Flow (gpm) 1 Minimum Flow i K -Factor (gpm) 1 (K) 1 Pressure (psi) ' Sprinkler 205 28.67 26.00 5.6 26.216 Sprinkler 209 29.34 26.00 5.6 27.451 1 Sprinkler 207 28.78 26.00 5.6 26.411 Sprinkler 202 26.36 26.00 5.6 22.158 Sprinkler 204 28.01 26.00 5.6 25.011 Sprinkler 203 26.93 26.00 5.6 1 23.129 ' Sprinkler 201 26.00 r 26.00 5.6 21.556 Sprinkler 210 29.38 26.00 5.6 27.516 Sprinkler 208 28.90 j 26.00 5.6 26.642 Sprinkler 206 28.75 I 26.00 5.6 26.353 b Most Demanding Sprinkler Data 6_k, © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 02/27/2008 8:14:19AM Page 2 Job Number: KSO255 Report Description: Racha Thai Kitchen Zone T5 Node Elevation(Foot) 1 Fittings Pressure(psi) 1 Discharge(gpm) 24 15-2 1 P0(5-0) 34.486 , 29 15-2 1 P0(5-0) ! PO(5-0) 33.120 i 31 15-2 32.853 42 15-2 2P0(8-0) 41.142 55 15-2 PO(8-0) 41.164 58 15-2 15-2 PO(5-0) 31.308 PO(5-0) 28.830 61 63 15-2 PO(5-0) 27.680 65 15-2 PO(5-0) 27.671 97 15-2 1 2P0(8-0) 41.259 101 15-2 P0(5-0) 34.569 103 15-2 P0(5-0) 33.422 105 15-2 P0(5-0) 33.042 327 1-11 P0(26-4) 61.249 364 3-10% BFP(-4.500) 64.950 400 205 1-11 10-0 LtE(16-0) Spr(-26.216) 61.266 26.216 28.67 209 10-0 Spr(-27.451) 27.451 29.34 207 10-0 Spr(-26.411) 26.411 28.78 202 10-0 Spr(-22.158) 22.158 26.36 204 10-0 Spr(-25.011) 25.011 28.01 203 10-0 Spr(-23.129) 23.129 26.93 201 10-0 Spr(-21.556) 21.556 26.00 210 10-0 Spr(-27.516) 27.516 29.38 208 10-0 Spr(-26.642) 26.642 28.90 206 10-0 Spr(-26.353) 26.353 28.75 1 -4-0 S 68.398 , 281.12 ©M.E.P.CAD, Inc. 419 AutoSPRINK® VR5 v5.2.6 02/27/2008 8:14:19AM Page 3 Job Number: KS0255 Report Description: Racha Thai Kitchen Zone T5 Pipe Type Diameter Flow Velocity HWC Friction Loss ; Length Pressure Length ' Summary Length Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings ' Eq. I Total Route 1 MS 1.049 0=26.00 9.65 C=120 0.21143428-6 Pf 8.355 201 10-0 q=26.00 K=5.6 21.556 Spr(-21.556) 11-0 Pe -2.240 65 15-2 27.671 3E(2-0), PO(5-0) 39-6 Pv BL 1.610 0=26.00 4.10 C=120 0.026249 0-4 Pf 0.009 65 15-2 27.671 Pe -0.000 63 15-2 27.680 0-4. Pv BL 1.610 Q=52.36 8.25 C=120 0.095845 12-0 Pf 1.150 63 15-2 27.680 I Pe -0.000 61 15-2 28.830 12-0 Pv BL 1.610 0=79.29 12.50 C=120 0.206534 12-0 Pf 2.478 61 15-2 28.830 Pe -0.000 58 15-2 31.308 12-0 Pv BL 1.610 0=107.30 16.91 C=120 0.361421 19-3 Pf 9.855 58 15-2 31.308 8-0 Pe -0.000 55 15-2 41.164 P0(8-0) 27-3 Pv CM 4.260 0=194.09 4.37 C=120 0.009468 10-1'/� Pf 0.096 55 15 2 41.164 Pe 97 15-2 41.259 10-1'% Pv CM 4.260 0=281.12 6.33 C=120 0.018788 402-0 Pf 14.249 97 15-2 41.259 196-91 Pe 5.741 327 1-11 61.249 2P0(26-4), 5fE(6-9%), 7fE(8-1 %), 598-9 Pv 2cplg(-1.500), 2EE(5-3), Eel (5 3), CV(28-11'/2), GV(2-7%) FM 8.329 0=281.12 1.66 C=120 0.000717 7-71 Pf 0.017 327 1-11 61.249 16-0 Pe -0.000 400 1-11 61.266 LtE(16-0) 23-7 Pv FM 10.420 0=281.12 1.06 C=120 0.000241 26-5Y Pf 4.526 400 1-11 61.266 83- Pe -0.842 364 3-10% 64.950 4LtE(16-0), BV(19-0), BFP(-4.500) 109-5% Pv UG 10.400 0=281.12 1.06 C=140 0.000183 109-2 Pf 0.040 364 3-10% 64.950 111-7 Pe 3.407 1 -4-0 68.398 E(35-1), 3LtE(25-6), S 220-9% Pv Route 2 MS 1.049 0=26.36 9.79 C=120 0.216895 26-9% Pf 7.761 202 10-0 q=26.36 K=5.6 22.158 Spr(-22.158) 9-0 Pe -2.240 63 15-2 27.680 2E(2-0), PO(5-0) 35-9% Pv v Route 3 MS 1.049 0=26.93 10.00 C=120 0.225669 26-2'/ Pf 7.941 203 10-0 q=26.93 K=5.6 23.129 Spr(-23.129) 9-0 Pe -2.240 61 15-2 28.830 2E(2-0), PO(5-0) 35-2'/2 Pv Route 4 MS 1.049 0=28.01 10.40 C=120 0.242607 26-2% Pf 8.537 204 10-0 q=28.01 K=5.6 25.011 Spr(-25.011) 9-0 Pe -2.240 58 15-2 31.308 2E(2-0), PO(5-0) 35-2'% Pv ill Route 5 MS 1.049 0=28.67 10.64 C=120 0.253395 26-0'/z Pf 8.877 205 10-0 q=28.67 K=5.6 26.216 Spr(-26.216) 9-0 Pe -2.240 31 15-2 32.853 2E(2-0), PO(5-0) 35-0% Pv BL 1.610 0=28.67 4.52 C=120 0.031458 8-6 Pf 0.267 Pe -0.000 8-J, Pv 8- , Pv 29 29 15-2 15-2 15-2 32.853 33.120 33.120 BL 1.610 0=57.45 9.05 C=120 0.113797 12-0 Pf 1.366 29 15-2 33.120 I Pe -0.000 24 15-2 34.486 12-0 Pv BL 1.610 0=86.79 13.68 C=120 0.244121 19-3 Pf 6.657 24 15-2 34.486 8-0 Pe -0.000 42 15-2 41.142 P0(8-0) 27-3 Pv CM 4.260 0=86.79 1.95 C=120 0.002136 9-10'h' Pf 0.021 42 15-2 41.142 1 I Pe 55 15-2 41.1649-10'/2 Pv Route 6 MS 1.049 0=28.75 10.67 C=120 0.254618 26-1 Pf 8.929 206 10-0 q=28.75 K=5.6 26.353 Spr(-26.353) 9-0 Pe -2.240 105 15-2 33.042 2E(2-0), PO(5-0) 35-1, Pv BL 1.610 0=28.75 4.53 C=120 0.031610 12-0 Pf 0.380 105 15-2 33.042 , ; Pe -0.000 103 15-2 33.422 12-0, Pv BL 1.610 0=57.65 9.09 C=120 0.114531 10-0 Pf 1.147 103 15-2 33.422 I Pe -0.000 101 15-2 34.569 10-0 Pv L, ©M.E.P.CAD, Inc. AutoSPRINKO VR5 v5.2.6 02/27/2008 8:14:20AM Page 4 r Hydraulic Analysis Job Number: KSO255 Report Description: Racha Thai Kitchen Zone T5 Pipe Type Diameter Flow Velocity HWC Friction Loss I Length Pressure Summary Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream Eq. Length 'Total Length BL 1.610 Q=87.03 13.71 C=120 0.245344 19-3 Pf 6.690 101 15-2 34.569 97 15-2 41.259 PO(8-0) 8-0 Pe -0.000 i 27-3' Pv Go Route 7 MS 1.049 Q=28.78 10.68 C=120 0.255139 1 26-1, Pf 8.949 207 10-0 q=28.78 K=5.6 26.411 Spr(-26.411) 29 15-2 33.120 2E(2-0), PO(5-0) 1 9-0 Pe -2.240 35-1, Pv Route 8 MS 1.049 Q=28.90 10.73 C=120 0.257200 ; 26-1 Pf 9.020 208 10-0 q=28.90 K=5.6 26.642 Spr(-26.642) 103 15-2 33.422 2E(2-0), PO(5-0) 9-0 Pe -2.240 35-1, Pv GP Route 9 MS 1.049 Q=29.34 10.89 C=120 0.264419 26-1 Pf 9.275 9-0 Pe -2.240 35-1 Pv 209 10-0 q=29.34 K=5.6 27.451 Spr(-27.451) 24 15-2 34.486 2E(2-0), PO(5-0) a Route 10 MS 1.049 Q=29.38 10.90 C=120 0.264996 26-11 Pf 9.293 210 10-0 q=29.38 K=5.6 27.516 Spr(-27.516) 101 15-2 34.569 2E(2-0), PO(5-0) 9-0 Pe -2.240 35-11 Pv Equivalent Pipe Lengths of Valves and Fittings (C-120 only) -1 C Value Multiplier 1 Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 Actual Inside Diameter ` 4.87 = Factor Schedule 40 Steel Pipe Inside Diameter 1\ ©M.E.P.CAD, Inc. dlAutoSPRINKO VR5 v5.2.6 02/27/2008 8:14:20AM Page 5 Hydraulic Analysis Job Number: KSO255 Report Description: Racha Thai Kitchen Zone T5 Pipe Type Downstream Upstream Diameter Elevation Flow Discharge Velocity HWC K -Factor Pt Pn Fittings Friction Loss Length Pressure Eq. Length Summary Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm -Over Diameter BL Branch Line Elevation CM Cross Main Flow DN Drain Discharge DR Drop Velocity DY Dynamic Pressure FM Feed Main Length FR Feed Riser Friction Loss MS Miscellaneous HWC OR Outrigger Pt RN Riser Nipple Pn SP Sprig Pf ST Stand Pipe Pe UG Underground Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV AngV b BaIV BFP BV C cplg Cr CV DeIV DPV E EE Eel Ee2 FDC fE fEE flg FN fT g GIoV GV Hose HV Hyd LtE mecT Noz P1 P2 PIV PO PrV PRV red S sCV Spr St T Tr U WirF WMV Z Alarm Valve Angle Valve Bushing Ball Valve Backflow Preventer Butterfly Valve Cross Flow Turn 90° Coupling Cross Run Check Valve Deluge Valve Dry Pipe Valve 90° Elbow 45° Elbow 111/4° Elbow 22W Elbow Flow Device Fire Department Connection 90° FireLock(TM) Elbow 45° FireLock(TM) Elbow Flange Floating Node FireLock(TM) Tee Gauge Globe Valve Gate Valve Hose Hose Valve Hydrant Long Turn Elbow Mechanical Tee Nozzle Pump In Pump Out Post Indicating Valve Pipe Outlet Pressure Relief Valve Pressure Reducing Valve Reducer/Adapter Supply Swing Check Valve Sprinkler Strainer Tee Flow Turn 90° Tee Run Union Wirsbo Water Meter Valve Cap �, ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 02/27/2008 8:14:20AM Page 6 Job Number: KSO255 Report Description: Racha Thai Kitchen Zone T5 Supply at Node 1 150 -Static Pressure 140.000 135 120 105 90 2 75 - a _ ai- 75 _ /n _ d o_ .531.12 81.12 with hose @ 68.398 streams 60 45 =System demand curve 30 10900.00 @ 20.000_ 15 1 Hi 111111111111111111 111111111 111111111 111111111 111111111 III 11 I III 1 1 1 1 1 1 1 1 1 111111111 0 11002200 3300 4400 5500 6600 7700 Water flow, gpm 8800 9900 11000 Hydrauhc Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.552 @ 531.12 System Demand 281.12 @ 68.398 System Demand (Including Hose Allowance) 531.12 @ 68.398 LM, ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 02/27/2008 8:14:21AM Page 7 ,Flow Diagram (Top View) Job Number: KSO255 Report Description: Racha Thai Kitchen Zone T5 ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 02/27/2008 8:14:21AM Page 8 Hydraulic Summary Job Number: KSO255 Report Description: Rach Thai -Seating Area -T5 Job Job Number KSO255 Design Engineer Martin Sokulski Job Name Racha Thai Kitchen State C.MobonRirnn Number WESTESF136QF Addles -II 1150 Southcenter Mall NU City of Tukwila Address 2 Job SIN Southcenter Mall Cdy Tukwila S. WA Ip Code 98188 Dm4n N. FP -1 Racha.cad System Remote Area(s) Most D.nendmg Sp ,kler D. 5.6 K -Factor 26.00 at 21.556 Dowp.n y Ordinary Group II Hon ABew... N Source 250.00 Dacey 0.20gpm/ft2 Area of Applc.lbn 1065.00ft2 (Actual 1069.83ft') Addelosl Hon Supplies Node Flow(gpm) Number Of Sprinklers Calculated 11 Coverage ler Sprinkler 130.00ft2 Total Hou Streams 250.00 System Flew Demand 326.57 Totel WW r Rewired (Including Hose Albw.ns) 576.57 Maximum Reason Unbalance In Loops 0.000 Maximum Velocity Above Ground 23.47 between nodes 141 and 182 Maximum VebnMy under Ground 1.23 between nodes 1 and 364 Volum. sp.dy d WN Rpee 2301.86ga1 Volume spay oI Dry Pipes 1.24ft' Supplies Node Hose Flow (gpm) Static (psi) Residual @ Flow (psi) (gpm) Available @ Total Demand (psi) (gpm) Required (psi) Safety Margin (psi) 1 250.00 140.000 20.000 1 10900.00 139.478 1 576.57 89.094 50.384 r � �r� i14-1 gi.� ea Contractor Contract. Hunner KS0255 Contact Name Martin Sokulski Gond Tele PM Contractor Nan Westem States Fire Protection Pee 425.881.0100 Esbrxbn 201 7108 180th Ave NE FAX 425.881.3030 ym 2 E.rnll martin.sokulski@wsfp.us Cly Redmond St.b WA W Code 98052 NMbSb (4j, ® M.E.P.CAD, Inc. jy'll AutoSPRINK® VR5 v5.2.6 03/17/2008 9:05:21AM Page 1 il Summary Of Outflowing Devices yob Number: KS0255 Report Description: Rach Thai -Seating Area -T5 Device Actual Flow (Wm) Minimum Flow (Qpm) K -Factor (K) Pressure (Psi) Sprinkler 113 32.34 26.00 5.6 33.348 Sprinkler 112 30.34 26.00 5.6 29.360 Sprinkler 110 29.14 26.00 5.6 27.074 Sprinkler 108 28.43 26.00 5.6 25.774 Sprinkler 109 28.66 26.00 5.6 26.191 Sprinkler 111 30.03 26.00 5.6 28.762 Sprinkler 107 27.78 26.00 5.6 24.601 Sprinkler 106 26.66 26.00 5.6 22.671 Sprinkler 104 26.13 26.00 5.6 21.771 c Sprinkler 102 26.00 26.00 5.6 21.556 Sprinkler 114 41.06 26.00 5.6 53.761 b Most Demanding Sprinkler Data ® M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 03/17/2008 9:05:46AM Page 2 Id Node Analysis Job Number. KSO255 Report Description: Rach Thai -Seating Area -T5 Node I Elevation(Foot) Fittings Pressure(psl) Discharge(gpm) 141 15-2 P0(8-0) 59.223 182 15-2 P0(5-0) 36.040 186 15-2 P0(5-0) 31.824 188 15-2 P0(5-0) 29.407 150 15-2 P0(5-0) 28.031 153 15-2 E(2-0) 27.713 161 15-2 2T(26-4) 59.409 216 15-2 P0(5-0) 32.297 175 15-2 6P0(8-0), 3C(8-0) 59.161 232 15-2 P0(5-0) 26.790 234 15-2 P0(5-0) 24.747 236 15-2 P0(5-0) 23.795 183 15-2 P0(5-0) 23.554 194 15-2 2P0(8-0) 59.154 255 15-2 P0(5-0) 57.593 327 1-11 P0(26-4) 81.918 364 3-10'/z BFP(-4.500) 85.633 400 1-11 LtE(16-0) 81.941 113 16-7'% Spr(-33.348) 33.348 32.34 112 16-7'% Spr(-29.360) 29.360 30.34 110 16-7% Spr(-27.074) 27.074 29.14 108 16-7% Spr(-25.774) 25.774 28.43 109 16-7% Spr(-26.191) 26.191 28.66 111 16-7% Spr(-28.762) 28.762 30.03 107 16-7% Spr(-24.601) 24.601 27.78 106 16-7% Spr(-22.671) 22.671 26.66 104 16-7'/ Spr(-21.771) 21.771 26.13 102 16-7% Spr(-21.556) 21.556 26.00 114 16-7% Spr(-53.761) 53.761 41.06 1 -4-0 S 89.094 326.57 6s, m M.E:P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 03/17/2008 9:06:01AM Page 3 1all t Hydraulic Analysis Job Number. KS0255 Report Description: Rach Thai -Seating Area -T5 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Eq. Length I Total Length 1 Pressure Summary Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings v Route 1 SP 1.049 0=26.00 9.65 C=120 0.211434 1-5'/ Pf 1.366 102 16-7% q=26.00 K=5.6 21.556 Spr(-21.556) 5-0 Pe 0.632 183 15-2 23.554 P0(5-0) 6-5''4 Pv BL 1.610 0=26.00 4.10 C=120 0.026249 9- Pf 0.241 183 15-2 23.554 Pe 236 15-2 23.795 9- Pv BL 1.610 0=52.13 8.22 C=120 0.095062 10-0% Pf 0.953 236 15-2 23.795 Pe 234 15-2 24.747 10-0% Pv BL 1.610 0=78.79 12.42 C=120 0.204132 10-0� Pf 2.043 234 15-2 24.747 I Pe 232 15-2 26.790 10-0 Pv BL 1.610 0=106.57 16.79 C=120 0.356880 11-5 Pf 5.507 232 15-2 26.790 4-0 Pe 216 15-2 32.297 2LtE(2-0) 15-5 Pv BL 1.610 0=136.60 21.53 C=120 0.564941 19-6'/� Pf 26.864 216 15-2 32.297 28-0 Pe 175 15-2 59.161 2LtE(2-0), 2P0(8-0), C(8-0) 47-6% Pv CM 4.260 0=177.66 4.00 C=120 0.008039 4-6 Pf 0.248 175 15-2 59.161 26-4 Pe 161 15-2 59.409 T(26-4) 30-10 Pv CM 4.260 0=326.57 7.35 C=120 0.024791 385-0 Pf 16.769 161 15-2 59.409 170-5 Pe 5.741 327 1-11 81.918 5fE(6-9%), 7fE(8-11%), 555-5 Pv 2cplg(-1.500), 2EE(5-3), Ee1(5-3), CV(28-11%), GV(2-7%), P0(26-4) FM 8.329 0=326.57 1.92 C=120 0.000947 7-7 Pf 0.022 327 1-11 81.918 16- Pe -0.000 400 1-11 81.941 LtE(16-0) 23-7l Pv FM 10.420 0=326.57 1.23 C=120 0.000318 26-5'% Pf 4.535 400 1-11 81.941 83-0 Pe -0.842 364 3-10% 85.633 4LtE(16-0), BV(19-0), BFP(-4.500) 109-5'% Pv UG 10.400 0=326.57 1.23 C=140 0.000241 109-2 Pf 0.053 364 3-10'/ 85.633 111-7 Pe 3.407 1 -4-0 89.094 E(35-1), 3LtE(25-6), S 220-9% Pv Gill Route 2 SP 1.049 0=28.13 9.70 C=120 0.213382 1-6 Pf 1.383 104 16-7'/ q=26.13 K=5.6 21.771 Spr(-21.771) 5-0 Pe 0.641 236 15-2 23.795 P0(5-0) 6-6 Pv GO Route 3 SP 1.049 0=26.66 9.90 C=120 0.221528 1-6-� Pf 1.435 106 16-7'/ q=26.66 K=5.6 22.671 Spr(-22.671) 5-q Pe 0.641 234 15-2 24.747 P0(5-0) 6- , Pv A Route 4 SP 1.049 0=27.78 10.31 C=120 0.238919 1-6 Pf 1.548 107 16-7'/ q=27.78 K=5.6 24.601 Spr(-24.601) 5-0 Pe 0.641 232 15-2 26.790 P0(5-0) 6-6 Pv o Route 5 SP 1.049 0=28.43 10.55 C=120 0.249436 1-6 Pf 1.616 108 16-7'/ q=28.43 K=5.6 25.774 Spr(-25.774) 5-0 Pe 0.641 150 15-2 28.031 P0(5-0) 6-6 Pv BL 1.610 0=57.09 9.00 C=120 0.112469 12-3 Pf 1.376 150 15-2 28.031 Pe 188 15-2 29.407 Z 12-3 Pv BL 1.610 0=86.23 13.59 C=120 0.241187 10-0% Pf 2.417 188 15-2 29.407 Pe 186 15-2 31.824 10-0'% Pv BL 1.610 0=116.57 18.37 C=120 0.421309 10 q Pf 4.216 186 15-2 31.824 Pe 182 15-2 36.040 10-0 Pv BL 1.610 0=148.91 23.47 C=120 0.662698 27-0 Pf 23.183 182 15-2 36.040 8-0 Pe 141 15-2 59.223 P0(8-0) 35-0 Pv CM 4.260 0=148.91 3.35 C=120 0.005799 5-9 Pf 0.186 141 15-2 59.223 26-4 Pe 161 15-2 59.409 T(26-4) 32-1 Pv NO Route 6 SP 1.049 0=28.66 10.64 C=120 0.253168 1-5' Pf 0.881 109 16-7'/ q=28.66 K=5.6 26.191 Spr(-26.191) 2 Pe 0.641 153 15-2 27.713 E(2-0) 3-5'% Pv (j ® M.E.P.CAD, Inc. AutoSPRINK®VR5 v5.2.6 03/17/2008 9:06:15AM Page 4 Hydraulic Analysis Job Number: KSO255 Report Description: Rach Thai -Seating Area -T5 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K -Factor Pt Pn Fittings,Eq. Upstream Length Summary Total Length BL 1.610 Q=28.66 4.52 C=120 0.031430 10-11// Pf 0.318 I Pe 0.000 10-1'/; Pv 153 15-2 27.713 160 15-2 28.031 © Route 7 SP 1.049 0=29.14 10.82 C=120 0.261058 1-6 Pf 1.691 5-d Pe 0.641 6-6 Pv 110 16-7% q=29.14 K=5.6 27.074 Spr(-27.074) 188 15-2 29.407 P0(5-0) wa Route 8 SP 1.049 0=30.03 11.15 C=120 0.276082 3-& Pf 2.893 7-dI Pe 0.641 10-61 Pv 111 16-7'% q=30.03 K=5.6 28.762 Spr(-28.762) 216 15-2 32.297 E(2-0), P0(5-0) a Route 9 SP 1.049 0=30.34 11.26 C=120 0.281381 1-6 Pf 1.823 5-d Pe 0.641 6-5 Pv 112 16-7% q=30.34 K=5.6 29.360 Spr(-29.360) 186 15-2 31.824 P0(5-0) a Route 10 SP 1049 0=32.34 12.00 C=120 0.316563 1-6 Pf 2.051 113 16-7% q=32.34 K=5.6 33.348 Spr(-33.348) 5-0 182 15-2 36.040 P0(5-0) 6-6, Pe 0.641 Pv = Route 11 SP 1049 0=41.06 15.24 C=120 0.492387 1-d 5-0 6-6 Pf 3.190 Pe 0.641 Pv 114 16-7'% q=41.06 K=5.6 53.761 Spr(-53.761) 255 15-2 57.593 P0(5-0) BL 1.610 0=41.06 6.47 C=120 0.061128 17-6% 8-0 25-6% Pf 1.562 Pe Pv 255 15-2 57.593 194 15-2 59.154 P0(8-0) CM 4.260 0=41.06 0.92 C=120 0.000535 12-0 12-0 P1 0.006 I Pe Pv 194 15-2 59.154 175 15-2 59.161 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) ` C Value Multiplier Actual Inside Diameter 4'87 Value 01 C 100 130 140 150 Schedule 40 Steel Pipe Inside Diameter ) = Factor Multiplying Factor 0.713 1.16 1.33 1.51 (As, ® M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 03/17/2008 9:06:15AM Page 5 Hydraulic Analysis Pipe Type Diameter Flow Job Number. KSO255 Report Description: Rach Thai -Seating Area -T5 Velocity HWC Friction Loss Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Length I Pressure Eq. Length Summary Total Length Pipe Type Legend Units Legend Fittings Legend AO BL CM DN DR DY FM FR MS OR RN SP ST UG Arm -Over Branch Line Cross Main Drain Drop Dynamic Feed Main Feed Riser Miscellaneous Outrigger Riser Nipple Sprig Stand Pipe Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV AngV b BaIV BFP BV C cplg Cr CV DeW DPV E EE Eel Ee2 FDC fE fEE flg FN fT 9 GIoV GV Hose HV Hyd LtE mecT Noz P1 P2 PIV PO PTV PRV red S sCV Spr St T Tr U WrF WMV Z Alarm Valve Angle Valve Bushing Ball Valve Backflow Preventer Butterfly Valve Cross Flow Turn 90° Coupling Cross Run Check Valve Deluge Valve Dry Pipe Valve 90° Elbow 45° Elbow 11W Elbow 22W Elbow Flow Device Fire Department Connection 90° FireLock(TM) Elbow 45° FireLock(TM) Elbow Flange Floating Node FireLock(TM) Tee Gauge Globe Valve Gate Valve Hose Hose Valve Hydrant Long Tum Elbow Mechanical Tee Nozzle Pump In Pump Out Post Indicating Valve Pipe Outlet Pressure Relief Valve Pressure Reducing Valve Reducer/Adapter Supply Swing Check Valve Sprinkler Strainer Tee Flow Tum 90° Tee Run Union Wirsbo Water Meter Valve Cap k, ® M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 03/17/2008 9:06:15AM Page 6 Hydraulic Graph Job Number: KS0255 Report Description: Rach Thai -Seating Area -T5 Supply at Node 1 1 G!1 ® W �a Pressure, psi cp o N N O A O O 8 N 8 LI 11111111 11 I I I A 111111111111111111111111111111111111111111111 1111111111111111111111_1.11.1111111111111 Static Pressure 140.000 with hose streams •576.57 326.57 @ 89.094 S tem demand curve_ 10900.00 © 20.000. I SII Ilillllli 111111111 'multi 111111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 I I I I 1 1 1 1 1 1 1 1 1 1 V 9100M 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hyslnulk Ompn Supply at Node 1 BM& Pmwn 140.000 R..Idu.I Rescue 10900.00 (4120.000 Anibl. PnesunTM MTM 139.478 © 576.57 Sywmo.n.nd 326.57 r@ 89.094 System Owen! (Malang Hos. AWnnu) 576.57 @ 89.094 M.E.P.CAD. Inc. AutoSPRINK® VR5 v5.2.6 03/17/2008 9:06:33AM Page 7 Flow Diagram (Top View) Job Number. KSO255 Report Description: Rach Thai -Seating Area -T5 �(, ® M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 03/17/2008 9:06:49AM Page 8 NOZZLE HEIGHT 42 IN PIP SIZE NI 3/8 total flow point 17 MOCTEZUMA 1l 5, - ,5aw4l7cea6. >I ANSUL R 102 C GL fire suppression system uI hood 14' DUCT 18x18 DUCT 18x18 FUSIBLE LINKS 450 ANSUL 6 GL maximum flow point 22 MECHANICAL GAS VALVES 6,4'44 /1d�e=G�`zb7 /6y,' SE 3,7L 2W r 2 /t "-if". 1N 1N -4 230 1N 1N 1N 245 1F1230 1F ct W w ›- u_ RIDDEL 24x42 GRIDDEL 24x42 GAS BROELLER 24x24 RANGE 24x36 W Q_' w iCG LL EXIT 5 MANUAL PULL 48" HEIGHT All cooking equipment undder the hood shll shut off when system is actuated & make up air unit and K CLASS FIRE EXTI gas shut valve to.fire suppression system shall be connected to the fire alarm system Installed by Frank fire portection inc 206 229 5245 PAID NOV ID 2014 TUKW1LA FIRE NOZZLE HEIGHT 42 IN PIP SIZE • 3/8 total flow point 13 ANSUL R 102 f GL fire suppression system uI hood 14' DUCT 18x18 FUSIBLE LINKS 450 ANSUL 6 GL maximum flow point 22 MECHANICAL GAS VALVES 2 "-OP 1N 3N 3N 3N 14x24 } brasing pan 1N RANGE EXIT ■ MANUAL PULL 48" HEIGHT All cooking equipment undder the hood shll shut off when system is actuated & make up air unit and K CLASS FIRE EXTI gas shut valve to.fire suppression system shall be connected to the fire alarm system Installed by Frank fire portection inc 206 229 5245 DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements —1.5 Gallon System DUCT, PLENUM, AND APPLIANCE PROTECTION 1. This option allows for duct protection, plenum protection, appliance protection, or any combination. 2. When using a combination of plenum and duct protection only, only one duct nozzle, either a 1W, 1100, or a 2W, may be used. ► 3. The previous Option 2 (using 2WH nozzle for plenum and duct protection) still can be utilized. For detailed design information, see previous version of this manual, Part No. 418087-06. Note: When using this option, all design parameters must be followed as listed in manual version -06. ► 4. All distribution piping, supply and branch, must be 3/8 in. Schedule 40 black iron, chrome -plated, or stainless steel. • 5. Each 1.5 gallon tank allows a maximum of five flow numbers.* • 6. The pipe length between the start of the first branch line and the start of the last branch line must not exceed 8 ft. (2.4 m). When the supply line is split, the combined length of both legs of the supply line (start of first branch line to start of last branch line) must not exceed 8 ft. (2.4 m). See Figure 92. 7. The combined length of all branch lines must not exceed 22 ft. (6.7 m). See Figure 93. ► 8. The requirements of the following table must not be exceeded: STAB L BRAItai LTC START OF FIRST BRANCH UNE SUPPLY UNE TEE ram_ u; MUST t&C' EXCaG (2.4 r.. START OF FIRST BRANCH UNE START OF LAST BRANCH LINE 1W NOZZLE FIGURE (BRANCH ONES IN BOLD) COMBINED LENGTH MUST NOT EXCEED 22 FT t.6_7 FIGURE Duct Plenum Appliance Reauirements Supply Branch Line )3ranch Line Branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft. 6 ft. 4 ft. 10 ft. (12.2 m) (1.8 m) (1.2 m) (3 m) Maximum Rise 6 ft. 4 ft. 2 ft. 2 ft. (1.8 m) (1.2 m) (.6 m) (.6 m) Maximum 90° Elbow 9 4 4 6 Maximum Tees 1 1 2 3 Maximum Flow Numbers 5* 2 2 3 ▪ * Exceptions: 1. Six (6) flow numbers are allowed when a duct branch line is the last branch line on the piping network and no 1N nozzles are used to protect woks or griddles. ► 2. Six (6) flow numbers are allowed when six (6) 1N nozzles are used and none of the nozzles are used to protect woks and griddles. NOTE: Only rive (5) flow numbers ace atm a 1N nozzle is used for wok or griddle protection. 3. Six (6) flow numbers are allowed when only two (2) 3N nozzles are used. DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements —1.5 Gallon System DUCT, PLENUM, AND APPUANCE PROTECTION 1. This option allows for duct protection, plenum protection, appliance protection, or any combination. 2. When using a combination of plenum and duct protection only, only one duct nozzle, either a 1W, 1100, or a 2W, may be used. 3. The previous Option 2 (using 2WH nozzle for plenum and duct protection) still can be utilized. For detailed design information, see previous version of this manual, Part No. 418087-06. Note: When using this option, all design parameters must be followed as Listed in manual version -06. 4. All distribution piping, supply and branch, must be 3/8 in. Schedule 40 black iron, chrome -plated, or stainless steel. 5. Each 1.5 gallon tank allows a maximum of five flow numbers.* 6. The pipe length between the start of the first branch line and the start of the last branch line must not exceed 8 ft. (2.4 m). When the supply line is split, the combined length of both legs of the supply line (start of first branch line to start of last branch line) must not exceed 8 ft. (2.4 m). See Figure 92. 7. The combined length of all branch lines must not exceed 22 ft. (6.7 m). See Figure 93. 8. The requirements of the following table must not be exceeded: 7.4 - • ST_L BRAM. START OF FIRST BRANCH UNE SUPPLY UNE TEE START OF FIRST BRANCH UNE START OF LAST BRANCH UNE 1W NOZZLE RGURE (BRANCH UNES IN BOLD) 1N NOZZLE COMBINED LENGTH W. NOT EXCEED 22 FT FIGURE Duct Plenum Appliance Requirements Supply Branch Line Branch Line Branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft. 6 ft. 4 ft. 10 ft. (12.2 m) (1.8 m) (1.2 m) (3 m) Maximum Rise 6 ft. 4 ft. 2 ft. 2 ft. (1.8 rn) (1.2 m) (.6 m) (.6 m) Maximum 90° Elbow 9 4 4 6 Maximum Tees 1 1 2 3 Maximum Flow Numbers 5* 2 2 3 r • Exceptions'. 1. Six (6) flow numbers are allowed when a duct branch line is the last branch fine on the piping network and no 1N nozzles are used to protect woks or griddles. 2. Six (6) flow numbers are allowed when sic (6) 1N nozzles are used and none of the nozzles are used to protect woks and griddles. NOTE: Only rive (5) flow numbers efe zek.ev. a 1N nozzle is used for wok or griddle protection. 3. Sbc (6) flow numbers are allowed when only two (2) 3N nozzles are used. SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-8 . REV.5 10-1-02 Fryer — Single Nozzle Protection (Continued) Maximum Area Dimensions — Single Nozzle Fryer Protection Max. Size Max. Size Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location Full or Split Vat Full or Split Vat 230 27 in_ to 47 in. See Figure ' 14 in. x 15 in. 14 in. x 21 in. (69 cm to 119 cm) 15 and 16 (36 cm x 38 cm) (36 cm x 53 cm) Full or Split Vat Full or Split Vat 245 20 in. to 27 in. See Figure 0- 14 in. x 15 in. 14 in. x 21 in. (51 cm to 69 cm) 15 and 16 (36 cm x 38 cm) (36 cm x 38 cm) iT-..�_ f-----... - 1 '' I 1 `—'r 11 1 1 iI 1 1 1 I Ii i I 4 I ! 1 I I 1 1 TOP OF FRYER 1 � FRYER WITHOUT DRIPBOARD FRYER W1TH DRIPBOARD NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 15 ► FIGURE 16 FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD SPLIT VAT NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-14 REV. 5 10-1-02 Range Protection 2 -Flow Nozzle High Proximity Application (2 -Flow Nozzle): 40 in. to 50 in. (102 cm to 127 cm) above the cooking surface. I. This high proximity application uses the 245 nozzle, Part No. 419340. The nozzle tip is stamped with 245 indicating this is a two -flow nozzle and must be counted as Iwo flow numbers. One 245 nozzle will. protect a maximum cooking area of 672 sq. in. (4335 sq. cm) with a maximum longest dimension of 28 in. (71 cm). When using this nozzle for range protection, the nozzle must be pointed vertically down and positioned as shown in Figures 29 and 30. 245 NOZZLE TIP LOCATION CENTERUNE OF COOKING SURFACE 1 401N. 1 (102 cm) 1 MINIMUM I HEIGHT OF 245 NOZZLE 1 ITP 1 00 4 1 501N. (127 cm) MAXIMUM HEIGHT OF 245 NOZZLE TIP 403238 FIGURE 29 NOTICE Four burner grates shown in Figure 30. For sin- * gle or double burner grates, locate nozzle at center of cooking surface or 11 3(8 in. (29 cm) maximum from nozzle centerline to center of any burner grate. 245 NOZZLE TIP LOCATION CENTER OF COOKING SURFACE OR 11 341 IN. (29 cm) MAXIMUM FROM CENTERUNE OF NOZZLE TO CENTER OF ANY ► BURNER GRATE COOKING AREA 245 NOZZLE TIP LOCATION CENTER OF COOKING SURFACE OR 11 3/81N. (29 cm) MAXIMUM FROM CENTERLINE OF NOZZLE TO CENTER OF ANY ► BURNER GRATE i COOKING AREA • COOKING AREA COOKING AREA ► 440768 FIGURE 3C SYSTEM DESIGN The Ansul R-102 Restaurant Fire Suppression System may be used on a number of different types of restaurant cooking appli- ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of the R-102 system must be trained and hold a current Ansul certificate in an R-102 training program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. • Both systems must actuate simultaneously. • Each system must be designed and installed per its appropri- ate manual. • Adjacent appliances requiring protection must be protected with the same type of system, either R-102 or PIRANHA, unless the center -to -center spacing between the adjacent R-102 and PIRANHA nozzles is no less than 36 inches. • When appliances are protected with R-102 nozzles, the hood and connecting duct above those appliances cannot be pro- tected with PIRANHA nozzles. • Mixing systems in a common plenum is not allowed. One of the key elements for restaurant fire protection is a correct system design. This section is divided into ten sub -sections: Noz- zle Placement Requirements, Tank Quantity Requirements, Actu- ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- tion Requirements, Mechanical Gas Valve Requirements, Electri- cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be completed before attempting any installation. System design sketches should be made of all aspects of design for reference during installation. ► NOZZLE PLACEMENT REQUIREMENTS This section gives guidelines for nozzle type, positioning, and quantity for duct, plenum, and individual appliance protection. This section must be completed before determining tank quantity and piping requirements. Duct Protection — Single Nozzle All duct protection is UL listed without limitation of maximum duct length (unlimited length). This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles to the horizontal and ducts with directional bends. The R-102 system uses different duct nozzles depending on the *size of duct being protected. ► GENERAL INFORMATION 1. Nozzles must be located 2-8 in. (5-20 cm) into the center ed duct opening, discharging up. See Figure 1. 2-8 IN. (5 — 20 cm) FIGURE 2.In installations where a UL listed damper assembly employed, the duct nozzle can be installed beyond the (20 cm) maximum, to a point just beyond the damper ase- bly that will not interfere with the damper. Exceeding the max mum of 8 in. (20 cm) in this way will not void the UL lis5- the system. 3. Previously listed 3 flow number and 5 flow number duct p; tection detailed in earlier published manual, Part No. 418'22 06, can also still by utilized. DUCT SIZES UP TO 50 IN. (127 cm) PERIMETER/ 16 IN. (41 cm) DIAMETER One 1100 nozzle (Part No. 430912) = one flow number 50 in. (127 cm) perimeter maximum 16 in. (41 cm) diameter maximum DUCT SIZES UP TO 100 IN. (254 cm) PERIMETER/ 32 IN. (81.3 cm) DIAMETER • One 2W Nozzle (Part No. 419337) = two flow numbers • 100 in. (254 cm) perimeter maximum • 32 in. (81.3 cm) diameter maximum • A 2WH nozzle (Part No. 78078) must be substituted to: a 21 nozzle for any installation using Option 2 of the 1.5 galbn sy tem coverage (duct and plenum protection only). A 2WH crit is limited to a maximum of 75 in. (190 cm) perimeter or a r*•_ mum diameter of 24 in. (61 cm) of coverage. The chart below shows the maximum protection availaIa each duct nozzle. Part Description No. 2W Nozzle 419337 1100 Nozzle 430912 3.0 Gallon 1.5 Gatti. System System Maximum 100 in. (254 cm) Perimeter Maximum 50 in. (127 cm) Perimeter Maximum 100 in. (2E -t Cr Perimet Maximum 50 in. (127' Perirnrte- 4 Plenum Protection The R-102 system uses the 1W Nozzle (Part No. 419336) or the o• 1100 Nozzle (Part No. 430192) or the 1N Nozzle (Part No. 419335) for plenum protection. The 1W nozzle tip is stamped with 1W and ►the 1N nozzle tip is stamped with 1N, indicating they are one -flow nozzles and must be counted as one flow number each. When pro- tecting a plenum chamber, the entire chamber must be protected ►regardless of filter length. ► VERTICAL PROTECTION — GENERAL ► One 1W nozzle or 1100 nozzle will protect 4 linear feet (1.2 m) of plenum. The maximum distance from the end of the hood to the first and last nozzle must be no more than 2 ft. (.6 m). After the first nozzle, any additional nozzles must be positioned at a maximum of 4 ft. (1.2 m) apart down the entire length of the plenum. The ► plenum width must not exceed 4 ft. (1.2 m). (The 1W or 1100 noz- zle can be used on single or V bank filter arrangements.) See ► Figure 6. 2 FT. (.6 m) MAXIMUM -► 4FT. (1.2m) MAXIMUM 4FT. (12m) 2 FT (.6 m) MAXIMUM MAXIMUM 4FT. (1.2m) MAXIMUM C FIGURE 6 000197 ► When protecting plenums with the 1W or 1100 nozzle, two options of coverage are available: + Option 1: The 1100 or 1W nozzle must be on the center line of the single or "V" bank filter and positioned within 1-20 in. (2.5-51 cm) above the top edge of the filter. See ► Figure 7. SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Paae 4 10-1-02 REV. 20 IN. (51 cm) MAXIMUM 1 IN. (2.5 cm) MINIMUM i 201N.(51cm; MAXIMUM 1 IN. (2.5 cm) MINIMUM FIGURE 7 Option 2: The 1W or 1100 nozzle must be placed perpendicular. 8-12 in. (20-30 cm) from the face of the filter and angled to the center of the filter. The nozzle tip must be within 2 in. (5 cm) from the perpendicular center line of the ' ter. See Figure 8. 4 IN. 12 IN. (30 cm) MAXIMUM (10 cm) NOZZLE TIP MUST BE WITHIN THIS AREA 8 IN. (20 cm) MINIMUM FIGURE 8 D. HORIZONTAL PROTECTION — OPTION 1 1N NOZZLE — PART NO. 419335 — SINGLE BANK PROTECTION One 1N nozzle will protect 10 linear feet (3.1 m) of single filter bank P. plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in - (5 to 10 cm) from the face of the filter, centered between the f(iter height dimension, and aimed down the length. See Figure 9. DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements —1.5 Gallon System DUCT, PLENUM, AND APPLIANCE PROTECTION 1. This option allows for duct protection, plenum protection, appliance protection, or any combination. 2. When using a combination of plenum and duct protection only, only one duct nozzle, either a 1W, 1100, or a 2W, may be used. 3. The previous Option 2 (using 2WH nozzle for plenum and duct protection) still can be utilized. For detailed design information, see previous version of this manual, Part No. 418087-06. Note: When using this option, all design parameters must be followed as listed in manual version -06. 4. All distribution piping, supply and branch, must be 3/8 in. Schedule 40 black iron, chrome -plated, or stainless steel. 5. Each 1.5 gallon tank allows a maximum of five flow numbers.* 6. The pipe length between the start of the first branch line and the start of the last branch line must not exceed 8 ft. (2.4 m). When the supply line is split, the combined length of both legs of the supply line (start of first branch line to start of last branch line) must not exceed 8 ft. (2.4 m). See Figure 92. 7. The combined length of all branch lines must not exceed 22 ft. (6.7 m). See Figure 93. 8. The requirements of the following table must not be exceeded: STAPJ OF BRA.' - i. START OF FIRST BRANCH UNE SUPPLY UNE TEE 1 40 TOTAL LE1 IALIST EXCE�::s (2.4r.' START OF FIRST BRANCH UNE START OF LAST BRANCH LINE 1W NOZZLE FIGURE (BRANCH UNES IN BOLD) COMBINED LENGTH 1T NOT EXCEED 22 Ft (63 c. RGURE Duct Plenum Appliance Requirements Supply Branch Line Branch Line Branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft. 6 ft. 4 ft. 10 ft. (12.2 m) (1.8 m) (1.2 m) (3 m) Maximum Rise 6 ft. 4 ft. 2 ft. 2 ft. (1.8 m) (1.2 m) (.6 m) (.6 m) Maximum 90° Elbow 9 4 4 6 Maximum Tees 1 1 2 3 Maximum Flow Numbers 5* 2 2 3 or•* Exceptions: 1. Six (6) flow numbers are allowed when a duct branch line is the last branch line on the piping network and no 1N nozzles are used to protect woks or griddles. 2. Six (6) flow numbers are aYowed when six (6) 1N nozzles are used and none of the nozzles are used to protect woks and griddles. NOTE: Only five (5) flow numbers az aka a 1N nozzle is used for wok or griddle protection. 3. Six (6) flow numbers are allowed when only two (2) 3N nozzles are used. Range Protection 1 -Flow Nozzle The R-102 system uses five different nozzles for the protection of ► ranges. Two of the design options require a one -flow nozzle and three of the design options require two -flow nozzles. NOTICE A 13 in. (33 cm) diameter wok pan is the largest wok size that can be protected on ranges. When protecting hot top ranges, the entire cooking surface must be protected. Range Protection (1 -Flow Nozzle) Single and multiple burner ranges can be protected using a IN nozzle, Part No. 419335. The nozzle tip is stamped with IN, indi- cating that this is a one -flow nozzle and must be counted as one flow number. When using this nozzle for range protection, the maximum length of the burner grates being protected with a single nozzle must not exceed 32 in. (81 cm) and the maximum area of the burner grates must not exceed 384 sq. in. (2477 sq. cm) per nozzle. When protecting a range, the 1N nozzle must be located a maxi- mum of 10 in. (25.4 cm) from each burner grate centerline and must be aimed at the center of the cooking surface. See Figure 26. 40 IN. (102 cm) I (76lcm % 3 6 cm) 4 1 006539 101N. (25 cm) MAXIMUM 1N NOZZLE 32 IN_ (81 cm) MAXIMUM 10 IN. (25 cm) MAXIMUM 006510 AIMING POINT FIGURE 26 SECTION IV - SYSTEM CES UL EX. 3470 ULC CEx747 3-104 When this type of hazard is equipped with a back see.` :.:s. above the range top, two protection options are ava :c a: requires a 1F nozzle, Part No. 419333, and the requires a 260 nozzle, Part No. 419341. Option 1: 1F Nozzle: When using the 1F nozzle for ra e tion with back shelf, the maximum length ct µa z_ -- grates being protected must not exceed 28 and the maximum area of the burner gra:es - exceed 336 sq. in. (2168 sq. cm). See Figure 2, - -: zle location details. 1F NOZZLE 40-48IN. (102 - 122 cm) SHELF CAN OVERHANG BUr . BY A MAXIMUM OF 11 111.12E : - AIM POINT oiger% "1411 41. 141N. (35.6 cm) MAXIMUM 121N. (30.5 cm) FRONT TO REAR MAXIMUM CENTERUNE 14 (3 � €: 1F NOZZLE LOCATED OVER FRONT EDGE OF BURNER GRATE AND OR:E7. u SO NOZZLE TIP FLATS ARE PARALLEL WITH BURNER GRATE FRONT TO REA,.. CENTERLINE AND SHALL BE AIMED AT THE CENTER OF THE COOKING S _ _ �_ FIGURE 2 Option 2: 260 Nozzle: When using the 260 nozzle for ra: ce tection with back sheff, the maximum length o: grates being protected must not exceed 32 in. IE _— and the maximum area of the burner grates exceed 384 sq. in. (2477 sq. cm). Nozzle must be ed on the front edge of the burner grates and a point 10 in. (25 cm) from the back edge of the ~-- er grates. Nozzle must be mounted 30 to 40 • 102 cm) above the hazard surface. See Figure 2E 260 NOZZLE SHELF CAN OVERHANG 8URUE'- 8Y A MAXIMUM OF 11 IN. 128 C. FIGURE 2? Griddle Protection 1 -Flow Nozzle The R-102 system uses four different nozzles for the protection of griddles. One of the applications requires a 1 -flow nozzle and three of the applications require a 2 -flow nozzle. High Proximity Application: 35 in. to 40 in. (89 to 102 cm) above the cooking surface. This high proximity application uses the 1N nozzle, Part No. 419335. The nozzle tip is stamped with 1N indicating this is a one -flow noz- zle and must be counted as one flow number. One 1N nozzle will protect a maximum cooking area of 1080 sq. in. (6968 sq. cm) with the maximum longest side of 36 in. (91 cm). When using this nozzle for griddle protection, the nozzle must be positioned along the cooking surface perimeter to a maximum of 2 in. (5 cm) inside the perimeter, and aimed to the midpoint of the ► cooking surface. See Figure 35 and 36. NOTICE When using this type of griddle protection, only 5 flow numbers are allowed on a 1.5 gallon sys- tem and only 11 flow numbers are allowed on a 3 gallon system. } MIDPOINT OF COOKING SURFACE 1 1 11 —�-2 1 1 1 1 1 L______ _ J 1N NOZZLE LOCATED ALONG ANY SIDE OF GRIDDLE SURFACE WITHIN 0 — 2 IN. (0 — 5 cm) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING SURFACE. COOKING SURFACE EDGE FIGURE 35 000241 ► SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-17 10-1-02 REV. 5 I NOZZLE LOCATION 1 1 0-2IN. (0-5 cm) 1 INSIDE PERIMETER 1+ OF COOKING SURFACE EDGE 1 OF —0I COOKING 1 SURFACE 1 t 35I%.122 c-) MIN:MUM HEIGHT OF 1N N0771 F TIP 40 IN. (102 cm) MAXIMUM HEIGHT OF 1N NOZZLE TIP FIGURE 36 SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-12 REV. 5 10-1-02 Multiple Nozzle Fryer Protection —Tilt Skillet / Braising Pan Protection for tilt skillets or braising pans is to be based upon the coverage limitations provided for deep fat fryer protection. Refer to ► Section IV, DESIGN, starting on Page 4-10, for maximum fryer nozzle coverages and maximum fryer nozzle height limitations. Although the maximum 6 sq. ft. total surface cooking area require- ment applies to fryer protection, it does not apply to tilt skillets or braising pans. Each tilt skilleUbraising pan protected module must not exceed the fryer limitations for "MAXIMUM SIZE MODULE OVERALL WITH DRIPBOARD" coverage per nozzle as described in Table on Page ► 4-11. Tilt skillets and braising pans generally utilize a hinged cover. Fryer protection nozzles are to be placed toward the front of the appli- ance to minimize the potential for the tilt skillet or braising pan ► cover to interfere with the nozzle discharge. See Figure 25. COVER MUST NOT I NOZZLE DISCHARG NTERFERE WITH E /.� WW1' THE NOZZLE IS TO BE PLACED TOWARD THE FRONT OF THE APPLIANCE TO MIM IZE THE POTENTIAL FOR THE SKILLET OR BRAISING PAN COVER TO IN i LHFERE WITH THE NOZZLE DISCHARGE. COVER MUST NOT �� INTERFERE WITH EDGE OF DISCHARGE PATTERN i / 77i i / FOR MINIMUM AND MAXIMUM / NOZZLE HEIGHTS, REFER TO FRYER / NOZZLE /,,,,, PARAMETERS 1 000071 FRYER NOZZLE USED FOR TILT SKILLET OR BRAISING PAN PROTECTION MUST BE POSITIONED NEAR THE FRONT EDGE OF THE PAN AND AIMED AT THE FRONT TO BACK CENTERLINE OF THE PAN. THE DISCHARGE FROM THE NOZZLE(S) MUST COMPLETELY CLEAR THE PAN COVER WITH AN UNOBSTRUCTED VIEW TO THE BACK OF THE PAN. FIGURE 25 Fryer — Multiple Nozzle Protection (Continued) Maximum Area Dimension — Multiple Nozzle Fryer Protection Max. Size Module Frypot Only 21 in. x 210 in.2 (53 cmx.14m2) 21 in. x 210 in.2 (53 cmx.14m2) 25 3/8 x 370.5 int (65 cm x .24 m2) 25 3/8 x 370.5 int (65 cm x .24 m2) 27 5/8 x 324 in.2 (70 cm x .21 m2) Max. Size Module Overall With Dripboard Type of Nozzle 21 in. x 294 in.2 230 (53 cmx.19m2) 21 in. x 294 in.2 245 (53 cm x .19 m2) 25 3/8 x 495 int 290 (65 cm x .32 m2) SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-11 3-1-04 REV.7 Nozzle Height Above Top of Fryer 27 in. to 47 in. (69 cm to 119 cm) 20 in. to 27 in. (51 to 69 cm) 13 in. to 16 in. (33 to 41 cm) 25 3/8 x 495 int 3N See Figure 23 (65 cm x 0.32 m2) 27 5/8 x 497 int 3N 25 in. to 35 inr (70 cm x .32 m2) (64 cm to 89 cm) Nozzle Location See Figure 21 See Figure 21 See Figure 22 See Figure 23 See Figure 24 34 IN. (86 cm) MAXIMUM DIAGONAL DISTANCE BETWEEN N0771 F AND CENTER OF HAZARD AREA J/ 1 1 FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 000218 000213 POSITION NOZZLE TIP ANYWHERE ALONG OR WITHIN THE PERIMETER OF THE MODULE IT IS PROTECTING AND AIM AT THE MIDPOINT OF THAT MODULAR AREA. FIGURE 21 FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE RESPECTIVE MODULAR AREA ± 3 IN. (7.6 cm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE MODULE AND z 1 IN. (2.5 cm) FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE MOD- ULE AND AIMED AT THE MIDPOINT OF THE MODULE. FIGURE 22 002290 21 in. (53 cm) MINIMUM VERTICAL NOZZLE HEIGHT FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP MUST BE POSITIONED ANYWHERE ALONG OR WITHIN THE PERIMETER OF THE MODULAR IT IS PROTECTING AND AIMED AT THE MIDPOINT OF THAT RESPECTIVE MODULE AREA. 'A; I CENTERLINE 00 AIM POINT (DIAGONAL CENTER OF MODULE COOKING AREA) RIGHT TO -LEFT FIGURE 23 AIM PONT (DIAGONAL CENTER ff I I MODIAF COOK,Y3 AREA FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD THE 3N NOZZLE TIP MUST BE POSITIONED ANYWHERE ALONG OR WITHIN THE PERIMLIEH AND FORWARD OF THE RIGHT-TO-LEFT CENTERUNE OF THE COOKING AREA. THE AIMING POINT OF THE NOZZLE MUST BE AT THE DIAGONAL CENTER OF THE MODULAR COOKING AREA. FIGURE 24 SECTION IV — SYSTEM DESIGN U! EX. 3470 ULC CEx747 Page 4-24 REV. 5 10-1-02 Electric Char -Broiler Protection The R-102 system uses the 1N nozzle for the protection of electric char -broilers. The maximum length of the hazard can be no longer than 34 in. (86 cm) and the total cooking area must not exceed 680 sq. in. (4388 sq. cm). 1. Nozzle Location: 20 to 50 in. (51 to 127 cm) above the grate surface. The 1N Nozzle (Part No. 419335) is used for electric char - broiler applications. The nozzle tip is stamped with 1 N, indi- cating that this is a one -flow nozzle and must be counted as one flow number. When using this nozzle for electric char -broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at ► the center of the cooking surface. See Figure 50. COOKING AREA \COOKING AREA 000253 / 50 IN. (127 cm) MAXIMUM 20 IN. (51 cm) MINIMUM 000254 ► FIGURE 50 Gas -Radiant Char -Broiler Protection The R-102 system uses the 1N nozzle, (Part No. 419335) for gas - radiant char -broiler protection. The nozzle tip on the 1N nozzle is stamped with a 1 N, indicating that this is a one -flow nozzle and must be counted as one flow number. One IN nozzle will protect a hazard with a maximum length of 36 in. (91 cm) and a total cooking area which does not exceed 864 sq. in. (5574 sq. cm). The nozzle tip must be located 15 to 40 in. (38 to 102 cm) above the hazard surface. When using this nozzle for gas -radiant char -broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at the center of the cooking sur- e. face. See Figure 51. Igi �qj' A.7 158 cm) s. I MINIMUM 1 401N. 1 (102 cm) i I MAXIMUM 1 000257 ► FIGURE 51 0 Without Comments As Noted in Red Pei 1 ne Attached Letter plans havE h<. - .t:on Bureau m -ds. Acce^ri - ons whicf r.. ,.ards anc r r.. ,acyofCE.�- fns, deiPtlor tc wily tra .rari'ttai of c =.iewed by The Tukwila Fire !•ormance with current City -object to errors and it 'ze violations of adopted • • , responsibility 'or the °Ler , with the designer. is'nns to these drawings aft- • .-Erica re and will require a • subsequent approval ai eccepta. iCF • nut'_ r!aIo test and inspection by e Tukwila - .ioreau. Date:./), 1‘I by: ib 15-'I ti .. e _7- A T 1 NT :;-:373-4407 and Fc; mf ' No. is tiFE_"' ',.,e;ra ANSUL FIER SUPPERSSION UL 300 Fire System rn '5 ("1 0 N N .N Q N N 1— Z Z D Q 0 FUSIBLE LINKS 450DEG COD O O CO t X CO s N 1 1 i C t_ 4.0.0 Z 0 w 10 bp 48'HEIGHT 15' WOK RANGE FIRE PROT CTION AND SVCS INC R z F.. al W 206 229 5245 K -CLASS FIRE EXTINGUISHER • LTL 300 Fire System FUSIBLE LINKS 450DEG 0 0 0 tt 1 1 -114Q1 . 04 , sF th g E- 0 a co oti U2 t en t EC. w —711 'a V. 04 rLie z / y4, ♦ N 1 —2e. `-`c N 0 v z z g 48'HEIGHT INSTALLED BY FIRE PROT CTION AND SVCS INC F- c_ 2 n. w 206 229 5245 K -CLASS FIRE EXTINGUISHER DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements — 6.0 Gallon Manifolded System As an option to piping two (2) 3.0 gallon tanks separately, two (2) 3.0 gallon tanks can be manifolded together to share a common agent distribution line. Only (2) 3.0 gallon tanks connected to the same regulator can be manifolded. The following requirements must be met when manifolding: 1. All piping must be 3/8 in. Schedule 40. ► 2. See Figure 96 for tank connections. 3. The length of supply line piping between the start of the first branch line and the start of the last branch line must not ► exceed 24 ft. (7.3 m). See Figure 95. When the supply line is split, the combined total of both legs of the supply line (from the start of the first branch line to the start of the last branch line) must not exceed 24 ft. (7.3 m). 4. The combined length of all branch lines must not exceed 36 ft. ► (10.9 m). See Figure 95. 5. A maximum of 22 flow numbers are allowed. 6. The requirements of the following table must not be exceeded. SECTION IV — SYSTEM DESII UL EX. 3470 ULC CEx747 Page 4- 3-1-04 RE\ LENGTH OF PIPING MUST NOT EXCEED 24 FT. (7.3 m) FROM START OF FIRST BRANCH LINE TO START OF LAST BRANCH LINE o 15 START OF LAST BRANCH LINE 2W NOZZLES 1N NOZZLE 2 FLOW APPLIANCE NOZZLE (BRANCH LINES IN BOLD) COMBINED LENGTH MUST NOT EXCEED 36 FT. (10.9 m) Duct Plenum Appliance -Requirements Supply Line Branch Line Branch Line Branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 32 ft. 8 ft. 4 ft. 12 ft. (9.7 m) (2.4 m) (1.2 m) (3.7 m) Maximum Rise 6 ft. 4 ft. 2 ft. 2 ft. (1.8 m) (1.2 m) (.6 m) (.6 m) Maximum 90° 8 4 4 6 Elbows Maximum Tees 2 2 2 4 Maximum Flow 22 4 2 4 Numbers 1N NOZZLE FIGURE Nozzle Application Chart Hazard Wood Fueled Char -Broiler Upright Broiler Salamander Broiler Wok (Continued) Maximum Hazard Dimensions Longest Side — 30 in. (76 cm) Area — 720 sq. in. (4645 sq. cm) Length — 32.5 in. (82.5 cm) 2 Width — 30 in. (76 cm) Length — 32.5 in. (82.5 cm) 2 Width — 30 in. (76 cm) 14 in. — 30 in. (36 — 76 cm) 1 Diameter 3.75 — 8.0 in. (9.5 — 20 cm) Deep 11 in. — 24 in. (28 — 61 cm) Diameter 3.0-6.0in. (8 — 15.2 cm) Deep Minimum Nozzle QuantitX 1 SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-31 3-1-04 REV.6 Nozzle Heights 14-40 in. (36 — 102 cm) 35 — 45 in. (89 — 114 cm) Nozzle Part No. 419338 419334 419334 419341 Nozzle Tip Stamping — Flow No. 3N 1 /2N 1 /2N 260 419335/417332 1 N/1 NSS SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-30 REV.3 10-1-02 Nozzle Application Chart (Continued) Hazard Maximum Hazard Dimensions Griddle Chain Broiler* (Overhead Protection) Chain Broiler (Horizontal Protection) Gas -Radiant Char -Broiler Electric Char -Broiler Lava -Rock Broiler Natural Charcoal Broiler Lava -Rock or Natural Charcoal Char -Broiler Longest Side (High Proximity) 48 in. (122 cm) Area — 1440 sq. in. (9290 sq. cm) Longest Side (High Proximity) 30 in. (76 cm) Area — 720 sq. in. (4645 sq. cm) Minimum Nozzle Nozzle Quantity Heights 1 30 — 50 in. (76 — 127 cm) (perimeter located) 1 30 — 50 in. (76 —127 cm) (center located) -Longest Side (High Proximity) 1 36 in. (91 cm) Area — 1080 sq. in. (6968 sq. cm) Longest Side 1 (Medium Proximity) 48 in. (122 cm) Area — 1440 sq. in. (9290 sq. cm) Longest Side (Low Proximity) 1 48 in. (122 cm) Area — 1440 sq. in. (9290 sq. cm) Longest Side — 34 in. (86 cm) 2 Area — 1088 sq. in. (7019 sq. cm) Length — 43 in. (109 cm) 2 Width — 31 in. (79 cm) Longest Side — 36 in. (91 cm) 1 Area — 864 sq. in. (5574 sq. cm) Longest Side — 34 in. (86 cm) 1 Area — 680 sq. in. (4388 sq. cm) Longest Side — 24 in. (61 cm) 1 Area — 312 sq. in. (2013 sq. cm) Longest Side — 24 in. (61 cm) 1 Area — 288 sq. in. (1858 sq. cm) Longest Side — 30 in. (76 cm) 1 Area — 720 sq. in. (4645 sq. cm) Nozzle Part No. Nozzle Tip Stamping — Flow No. 419341 260 (perimeter located) 20 — 30 in. (51 — 76 cm) (perimeter located) 10 — 20 in. (25 — 51 cm) (perimeter located) 10 — 26 in. (25 — 66 cm) 1 — 3 in. 419342 290 419335/417332 1N/1NSS 419342 290 419343 2120 419336/417333 1 W/1 WSS 20 — 50 in. (51 — 127 cm) 18 — 35 in. (46 — 89 cm) 18 — 40 in. (46 — 102 cm) 14-40 in. (36 —102 cm) 419335/417332 1N/1NSS 419335/417332 1N/1NSS 419335/417332 1N/1NSS 419335/417332 1N/1NSS 419335/417332 1N/1NSS 419338 3N Minimum chain broiler exhaust opening — 12 in. x 12 in. (31 cm x 31 cm), and not less than 60% of internal broiler size. Nozzle Application Chart (Continued) Hazard d —_-- Fryer (Non -Split Vat Only)* Range SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-29 3-1-04 REV.4 Maximum Hazard Minimum Nozzle Nozzle Nozzle Tip Dimensions Ouanti Nozzle Stamping — t ILi hts Part No Flow No Maximum Size (with drip board) 21 in. (53 cm) x 14 in. (36 cm) (Fry Pot must not exceed 15 in. x 14 in. (38 cm x 36 cm)) High Proximity 1 Medium Proximity 1 27 — 47 in. 419339 230 20 — 27 in. 419340 245 Maximum Size (with drip board) 25 3/8 in. (64.4 cm) x 19 1/2 in. (49.5 cm) (Fry pot side must not exceed 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity 1 Low Proximity 21 — 34 in. 419338 3N 1 13 — 16 in. 419342 290 Maximum Size (with drip board) 18 in. (45.7 cm) x 27 5/8 in. (70.2 cm) High Proximity 1 25 — 35 in. 419338 (64-89 cm) 3N Longest Side 1 32 in. (81 cm) 30 — 40 in. 419335 1N Area — 384 sq. in. (76 —102 cm) (2477 sq. cm) Longest Side 28 in. (71 cm) 40 — 48 in. 419333 1F Area — 336 sq. in. (102 —122 cm) (2168 sq. cm) (With Backshelfl Longest Side (High Proximity) 1 28 in. (71 cm) 40 — 50 in. 419340 245 Area — 672 sq. in. (102 —127 cm) (4335 sq. cm) Longest Side (Medium Proximity) 1 32 in. (81 cm) 30 — 40 in. 419341 260 Area — 768 sq. in. (76 — 102 cm) (4955 sq. cm) Longest Side (Low Proximity) 2 36 in. (91 cm) 15 — 20 in. 419342 290 Area —1008 sq. in. (38 — 51 cm) (6503 sq. cm) SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-28 REV.4 3-1-04 Nozzle Application Chart The following chart has been developed to assist in calculating the quantity and type of nozzle required to protect each duct, plenum, or appliance. NOTICE This chart is for general reference only. See complete details for each type of hazard. Hazard Duct or Transition (Single Nozzle) Duct or Transition (Single Nozzle) Duct or Transition (Dual Nozzle) Electrostatic Precipitator (At Base of Duct) Plenum (Horizontal Protection) Plenum (Horizontal Protection) Plenum (Vertical Protection) 0- Fryer (Split or Non -Split Vat)* Fryer (Non -Split Vat Only) Maximum Hazard Dimensions Length — Unlimited Perimeter — 50 in. (127 cm) Diameter — 16 in. (40.6 cm) Length — Unlimited Perimeter —100 in. (254 cm) Diameter — 31 7/8 in. (81 cm) Length — Unlimited Perimeter — 150 in. (381 cm) Diameter — 48 in. (122 cm) Individual Cell Minimum Nozzle Nozzle Quanti Heights 1 1 2 1 Length — 10 ft. (3.1 m) 1 Length — 6 ft. (1.8 m) 1 Width — 4 ft. (1.2 m) 1 Length — 4 ft. (1.2 m) 1 Width — 4 ft. (1.2 m) Maximum Size (without drip board) 15 in. (38 cm) x 14 in. (36 cm) High Proximity 1 Medium Proximity 1 Maximum Size (without drip board) 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity 1 Low Proximity 1 Maximum Size (without drip board) 18 in. (45.7 cm) x 18 in. (45.7 cm) High Proximity 1 :or multiple nozzle protection of single fryers, see detailed information on Pages 4-12 through 4-14. 27 — 47 in. 20 — 27 in. 21 — 34 in. 13 — 16 in. 25 — 35 in. (64-89 cm) Nozzle Part No. 430912 419337 419337 419334 419335 430192 419336 419336 419339 419340 419338 419342 419338 Nozzle Tip Stamping — FlowwNg. 1100 2W 2W 1/2N- 1N /2N 1N 1100 1W 1W 230 245 3N 290 3N Wok Protection The R-102 system uses two different nozzles for the protection of woks. 1. A 260 nozzle, Part No. 419341, will protect a wok 14 in. (36 cm) minimum diameter up to 30 in. (76 cm) maximum diameter. The wok depth must be no less than 3.75 in. (9.5 cm) and no greater than 8 in. (20 cm). The nozzle tip is stamped with 260 indicating that this is a two - flow nozzle and must be counted as two flow numbers. When using this nozzle, the nozzle must be positioned as I. shown in Figure 56. NOZZLE MUST BE POSITIONED WITHIN 1 IN. (2 cm) RADIUS OF THE CENTER OF THE WOK, POINTED VERTICALLY DOWN 260 NOZZLE MINIMUM DEPTH 3.75 IN. (9.6 cm) MAXIMUM DEPTH 8 IN. (20 cm) i 35-45 IN. (89-114cm) t s. 14 IN. (35.6 cm) MINIMUM DIAMETER 30 IN. (762 cm) MAXIMUM DIAMETER FIGURE 56 000261 UL EX. 3470 ULC CEx747 Page 4-27 10-1-02 REV.4 2. A 1N Nozzle, Part No. 419335, will protect a wok 11 in. (28 cm) minimum diameter up to 24 in. (61 cm) maximum diameter. The wok depth must be no Tess than 3 in. (8 cm) and no greater than 6 in. (15 cm). The nozzle tip is stamped with 1N indicating that this a one -flow nozzle and must be counted as one flow number. When using this nozzle, the nozzle must be positioned anywhere along or within the perimeter of the wok, aimed at the center, 30 in. to 40 in. (76 to 102 cm) above the ► hazard surface, as shown in Figure 57. a. NOTICE When using this type of wok protection, only 5 flow numbers are allowed on a 1 1/2 gallon system, and only 11 flow numbers are allowed on a 3 gallon system. MINIMUM DEPTH 3.0 IN. (7.6 cm) MAXIMUM DEPTH 6.0 IN. (15 cm) 11 IN. (28 cm) MINIMUM DIAMETER 24 IN. (61 cm) MAXIMUM DIAMETER FIGURE 57 000261 SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-24 REV. 5 10-1-02 Electric Char -Broiler Protection The R-102 system uses the 1N nozzle for the protection of electric char -broilers. The maximum length of the hazard can be no longer than 34 in. (86 cm) and the total cooking area must not exceed 680 sq. in. (4388 sq. cm). 1. Nozzle Location: 20 to 50 in. (51 to 127 cm) above the grate surface. The 1N Nozzle (Part No. 419335) is used for electric char - broiler applications. The nozzle tip is stamped with 1 N, indi- cating that this is a one -flow nozzle and must be counted as one flow number. When using this nozzle for electric char -broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at the center of the cooking surface. See Figure 50. COOKING AREA COOKING AREA 50 IN. (127 cm) MAXIMUM 20 IN (51 cm) MINIMUM 000254 FIGURE 50 r. Gas -Radiant Char -Broiler Protection The R-102 system uses the 1N nozzle, (Part No. 419335) for gas - radiant char -broiler protection. The nozzle tip on the 1N nozzle is stamped with a 1N, indicating that this is a one -flow nozzle and must be counted as one flow number. One IN nozzle will protect a hazard with a maximum length of 36 in. (91 cm) and a total cooking area which does not exceed 864 sq. in. (5574 sq. cm). The nozzle tip must be located 15 to 40 in. (38 to 102 cm) above the hazard surface. When using this nozzle for gas -radiant char -broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at the center of the cooking sur - 0. face. See Figure 51. 1 ( 15 IN. (38 cm) MINIMUM 40 IN. (102 cm) MAXIMUM 000257 FIGURE 51 SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-14 REV. 5 10-1-02 Range Protection 2 -Flow Nozzle High Proximity Application (2 -Flow Nozzle): 40 in. to 50 in. (102 cm to 127 cm) above the cooking surface. ► This high proximity application uses the 245 nozzle, Part No. 419340. The nozzle tip is stamped with 245 indicating this is a two -flow nozzle and must be counted as two flow numbers. One 245 nozzle will protect a maximum cooking area of 672 sq. in. (4335 sq. cm) with a maximum longest dimension of 28 in. (71 cm). When using this nozzle for range protection, the nozzle must be pointed vertically down and positioned as shown in Figures ▪ 29 and 30. 245 NOZZLE TIP LOCATION CENTERLINE OF COOKING SURFACE 50 IN. (127 cm) MAXIMUM HEIGHT OF 245 NOZZLE TIP 40 IN. (102 cm) MINIMUM HEIGHT OF 245 NOZZLE 1 TIP 00 4 000236 FIGURE 29 NOTICE ' Four burner grates shown in Figure 30. For sin- ► gle or double burner grates, locate nozzle at center of cooking surface or 11 3/8 in. (29 cm) maximum from nozzle centerline to center of ► any burner grate. 245 NOZZLE TIP LOCATION CENTER OF COOKING SURFACE OR 11 3/8 IN. (29 cm) MAXIMUM FROM CENTERLINE OF NOZZLE TO CENTER Or ANY ► BURNER GRATE COOKING AREA 245 NOZZLE TIP LOCATION CENTER OF COOKING SURFACE OR 11 3/8 IN. (29 cm) MAXIMUM FROM CENTERLINE OF NOZZLE TO CENTER OF ANY ► BURNER GRATE Dc i COOKING AREA ' COOKING AREA COOKING AREA 000766 FIGURE 30 SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-8 REV. 5 10-1-02 Fryer — Single Nozzle Protection (Continued) Maximum Area Dimensions — Single Nozzle Fryer Protection Max. Size Max. Size Overall Type of Frypot Only With Dripboard Nozzle Full or Split Vat Full or Split Vat 230 '14in. x15in. 14in. x21 in. (36 cm x 38 cm) (36 cm x 53 cm) Full or Split Vat Full or Split Vat 245 ►14in. x 15 in. 14in. x21 in. (36 cm x 38 cm) (36 cm x 38 cm) TOP OF FRYER I FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 15 002280 Nozzle Height Above Top of Fryer 27 in. to 47 in. (69 cm to 119 cm) 20 in. to 27 in. (51 cm to 69 cm) Nozzle Location See Figure 15 and 16 See Figure 15 and 16 TOP OF FRYER FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD SPUT VAT NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 16 002283 SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-6 REV. 4 10-1-02 Plenum Protection (Continued) HORIZONTAL PROTECTION — OPTION 2 1100 NOZZLE — PART NO. 430912 — "V" BANK PROTECTION 1W NOZZLE — PART NO. 419336 One 1100 or 1W nozzle will protect 6 linear feet (1.8 m) of "V" bank plenum. The nozzle must be mounted horizontally, positioned 1/3 the filter height down from the top of the filter. Nozzles can be located at 6 ft. (1.8 m) spacings on longer plenums. See Figure 10. 1100 NOZZLE OR 1W NOZZLE 1/3 (H) t HEIGHT OF FILTER (H) 4 FT. (1.2 m) MAXIMUM FIGURE 10 1N NOZZLE — PART NO. 419335 — "V" BANK PROTECTION Two IN nozzles will protect 10 linear feet (3.1 m) by 4 ft. (1.2 m) wide of "V" bank plenum. The nozzles must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. See Figure 11. 006524 FIGURE 11 For a plenum, either single or "V" bank, with a linear extension longer than 10 feet (3.1 m), each bank may be protected using one 1N nozzle every 10 ft. (3.1 m) or less depending on the overall length of the plenum. See Figure 12. The nozzles may point in the opposite directions as Tong as the entire plenum area is protected, and the 10 ft. (3.1 m) limitation is not exceeded. See Figure 13. The nozzle positioning shown in Figure 14 is not an acceptable method of protection because the plenum area directly under the tee is not within the discharge pattern of either nozzle. ��a�M 10FT. (3.1 m) MAXIMUM 10FT. (3.1m) MAXIMUM 10 FT.(3.1m) MAXIMUM 010 tN 10 FT(3.1m) MAXIMUM 30 FT (9.1 m) 10 FT. (3.1 m) MAXIMUM 10 FT (3.1 m) MAXIMUM FIGURE 12 000206 30 FT. (9.1 m) FIGURE 13 000207 FIGURE 14 SYSTEM DESIGN The Ansul R-102 Restaurant Fire Suppression System may be used on a number of different types of restaurant cooking appli- ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of the R-102 system must be trained and hold a current Ansul certificate in an R-102 training program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated ActUators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. • Both systems must actuate simultaneously. • Each system must be designed and installed per its appropri- ate manual. • Adjacent appliances requiring protection must be protected with the same type of system, either R-102 or PIRANHA, unless the center -to -center spacing between the adjacent R-102 and PIRANHA nozzles is no less than 36 inches. • When appliances are protected with R-102 nozzles, the hood and connecting duct above those appliances cannot be pro- tected with PIRANHA nozzles. • Mixing systems in a common plenum is not allowed. One of the key elements for restaurant fire protection is a correct system design. This section is divided into ten sub -sections: Noz- zle Placement Requirements, Tank Quantity Requirements, Actu- ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- tion Requirements, Mechanical Gas Valve Requirements, Electri- cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be completed before attempting any installation. System design sketches should be made of all aspects of design for reference during installation. ► NOZZLE PLACEMENT REQUIREMENTS This section gives guidelines for nozzle type, positioning, and quantity for duct, plenum, and individual appliance protection. This section must be completed before determining tank quantity and piping requirements. Duct Protection — Single Nozzle All duct protection is UL listed without limitation of maximum duct length (unlimited length). This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles to the horizontal and ducts with directional bends. The R-102 system uses different duct nozzles depending on the size of duct being protected. SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-1 10-1-02 REV.5 ►GENERAL INFORMATION 1. Nozzles must be located 2-8 in. (5-20 cm) into the center of the duct opening, discharging up. See Figure 1. 2-8 IN. (5 — 20 cm) FIGURE 1 000173 2. In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (20 cm) maximum, to a point just beyond the damper assem- bly that will not interfere with the damper. Exceeding the maxi- mum of 8 in. (20 cm) in this way will not void the UL listing of the system. 3. Previously listed 3 flow number and 5 flow number duct pro- tection detailed in earlier published manual, Part No. 418087- 06, can also still by utilized. DUCT SIZES UP TO 50 IN. (127 cm) PERIMETER/ 16 IN. (41 cm) DIAMETER • One 1100 nozzle (Part No. 430912) = one flow number • 50 in. (127 cm) perimeter maximum • 16 in. (41 cm) diameter maximum DUCT SIZES UP TO 100 IN. (254 cm) PERIMETER/ 32 IN. (81.3 cm) DIAMETER • One 2W Nozzle (Part No. 419337) = two flow numbers • 100 in. (254 cm) perimeter maximum • 32 in. (81.3 cm) diameter maximum • A 2WH nozzle (Part No. 78078) must be substituted for a 2W nozzle for any installation using Option 2 of the 1.5 gallon sys- tem coverage (duct and plenum protection only). A 2WH nozzle is limited to a maximum of 75 in. (190 cm) perimeter or a maxi- mum diameter of 24 in. (61 cm) of coverage. The chart below shows the maximum protection available from each duct nozzle. Part Description No. 2W Nozzle 419337 1100 Nozzle 430912 3.0 Gallon 1.5 Gallon System System Maximum 100 in. (254 cm) Perimeter Maximum 50 in. (127 cm) Perimeter Maximum 100 in. (254 cm) Perimeter Maximum 50 in. (127 cm) Perimeter • 0 'N. �: fir 7 0 Without Comments As Noted In Red 0 Per The Attached Letter i nese plans have he,-*: reviewed by The Tukwila Fire Prevention Bure,sa `Gr vc • , •<. ice w to current city standards. Acca,V'a7., . to errors and omissions which d ; ,,ui vi:, ations of adopted standards and or m nc -:. 1 F rt..;ronsiti'lty for the adequacy of o tot, r,i tt e des-gner. Additions, < a7E to draw ngs atter this dat. will vc,, rt << , _ c:: ,nce ^nd w11 require a . resubmittal of revi.;cd d'Lit.,+• s for subsequent approval. Final acceptance is subject to field test and inspection by Thi Tukwila Fire Prevention Bureau. Date: S 1 1— ° By: a •8 rUKWILA FIRE DEPARTM AI Please call: 575.4402 and give this job No.Sj 914-15)- ant Exact address for shut. -1,4uvn or r^st,:ration aonrnvall MOCTEZUMA' S FIRE A RESTAURA ARM SYSTEM TUKWILA, WASHIN T TE • UILA BAR ADDITION TON Pll SHEET \UM�E� SHEET TITLE FA -01 SYSTEM INFO V ATI O \ FA -02 TYPICAL WRI\G A\D iv OU\ TI\ G DETAILS FA -03 SYSTEM CALC U LATI O \S A\D SINGLE LI\E DIAGAN FA -04 FIDE ALARM SYSTEM PLAN SHEET INDEX 1'•: C.i _ L. ww Icy Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Ffre evention Bureau for conformance with current City ;1:::,ndards, Acceptance is subject to errors and nrnissions which do not authorize violations of adopted andards and ordinances. The responsibility for the ;{Jequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a :submittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Preventiorn Bureau. Date: /0- By' By: sci NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing 'TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. a Ll 0 and exact address for shut- down hundown or restoration .rov IIDULE A\D CCU\�UIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPUFPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.' 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL. DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY: ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMLM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WI -ERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 1 2 8 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ (PHOTO -ADDRESSABLE) DB -11 BASE SIEMENS 4S DEEP W/ 1G RING CEILING ® DUCT DETECTOR D FDBZ492-HR W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD HT -M SINGLE INPUT INTERFACE MINIMODULE HTRI-M SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING 0,1 FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXTN A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND z 0 w w w J w 0\ 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 J REV. BY: cD m 0 DESCRIPTION SHOP DRAWINGS W a o h. 0 cc m mervyri c''s 2 LEVELS 65,237sf macys 4 LEVELS 250, 407s f NORDSTROM 3 LEVELS 171,275sf PAYLESS SI0E50URCE JUST SPOR15 wouc coca. 1HE 700 SHOP A SIRRTZ TO GO JWCS *1 JRGIIE W111S*40 WORKWEAR WG ,1 1%, TE ,ELIOSD CN010E CASUAL KING COUNTY UORARY �000 MEYER JCWELERS ] . SUER k 0010 ffNNMMr 'i'. INNO'.S I I GAtELSTh' 5TAN0 080 &AI:K 5U GORDON'S JEWELERS, os BEN R1DOE JLB 5 ' 0*1511NC . JCPenney . e LEVELS. . CLAIRE'S BIAGIO MOOIERHOCO MATE WALDENBOOKS 504100N WRELESS 020 I01UI40 PEOPLE. STARE 0K 'WASS .1EAM STOP 005KIN I 0 n ROBOINS ▪ 3 LEVELS . 276,4G8n f MADE IN WASHINGION AOEP.CROMBiE• 1 PAWIC SUNWEAR SPENCER OIE1S • EARS 2914 ,l'W fix, 01011101 a _f PAT/ Al/ RES1A0RPM A110 WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright PAID OCT 21214 TUKWILAFI-F CG /Z0 W E- z _c OQ� Z tWo I- CC WZz_ U= <comQ Ci) cc W CC Q W� Co CI TF- N W U 0 Z 0 cc 0 Z GALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:10/17/14 BACKROUND PLAN PROVIDED BY: 2013 by Guardian Security Systems, Inc. All Rights Reserved .10B NUMBER: 10464-19 r SHEET ( 1 ; FA -019' FROM PREVIOUS ADDRESSABLE 2 DEVICE HFP-11 TB1 NO COM NC 2 TO FAN 2 SHUTDOWN EOLR 470 SWITCH + - INPUT LED TSM -1 HTRI-M RED BLK ORG ORG GRN + 2TONEXT a - ADDRESSABLE DEVICE N OTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL DUCT DETECTOR/HTRI-M MODULE/TSM-1 SWITCH WIRING DETAIL COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR i+ PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH 0 GROUND 0 0 r) 0 O HTRI-R OSTATUS LED 0 N.O. 0 COM C0 N.C. 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. MUSIC j-AC POWER SOURCE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING RELAY CONTACTS (4.OA @ 125VAC) (4,OA @ 30VDC) THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS DUCT DETECTOR L❑CATION FDBZ4092-HR DUCT DETECTOR MOUNTING DETAIL FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) JUNCTI❑N BOX MOUNTED ON CEILING, FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT / / / J O 0 TO NEXT DEVICE / / L O O -.-CADDY BAR SMOKE DETECTOR ----- \- SUSPENDED ( ILLUMINATED CEILING HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL SMOKE DETECTOR MOUNTING DETAIL TYPICAL WIRING AND MOUNTING DETAILS NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERATURE: +32' F 0' C TO 100' F (38' C) HUMIDITY: -9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTIONMTh! DUCT HOUSINGS AD -11P OR AD-11XPR r DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW TO NEXT DEVICE ( ) DATA OUT (+) DATA OUT HFP-11 SMOKE DETECTOR WIRING DETAIL () () STROBE SPEAKER () () ((+) ) STROBE C (+) ( ) STROBE SPEAKER C �) SPEAKER STROBE & STROBE WIRING DETAIL HARD LID —\ CEILING SPEAKER SUPPORT TILE BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE -r N 0 12 a a a as CC CO 5 w Z .0000 W O Q � ;"oz Q `t WO~ CC w611 zz <r01a cn cc w ° _g CC Q W N w U 0 4CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/ 17/ 14 BACKROUND PLAN PROVIDED BY: .JOB NUMBER:10464-1} SHEET FA -02 MOCTEZUMA'S RESTAURANT EXISTING SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: r. 0 Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -CW @15Cd 14 0.069 0.966 SET -MC -CW @30Cd 10 0.111 1.110 SET -MC -CW @75Cd 6 0.200 1.200 SET -MC -CW @95Cd 5 0.264 1.320 ZR -MC -CW @15Cd 15 0.069 1.035 ZR -MC -CW @30Cd 0.111 0.03 Amps 5.661 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 5.661 Amps For 5 Minutes= 0.476 Amp -hours 25% Derating= 1.494 Amp -hours Total System Current Load: 1.494 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH FDBZ492 Duct Housing HTR, R Modulo 3: HTR1-M Module PROJECT: Panel: Date: ._....__.....Notification Appliance Circuit Detail MOCTEZUMA'S RESTAURANT EXISTING PAD -3 POWER SUPPLY October 20, 2014 !Wire Resistance 2.58 CURRENT TOTAL=' 1379 CIRCUIT: S1 QTY Device Type SET -MC -CW @15Cd 4 .SET -MC -CW @30Cd SET -MC -CW @75Cd SET -MC -CW @95Cd DEVICES= CIRCUIT: QTY1...._._.._..._ 'ZR -MC -CW @15Cd ZR -MC -CW @30Cd Alarm Current 69 111 200 264 69 111 TOTAL mA= S2 Device Type Alarm Current SET -MC -CW @15Cd SET -MC -CW @30Cd 1 !SET -MC -CW @75Cd 2 1SET-MC-CW @95Cd 2 1ZR-MC-CW @15Cd 9 ?ZR -MC -CW @3OCd 111 DEVICES= 6 TOTAL mA- 69 111 200 264 6 Alarm Total Wire Size 0 4441 0 0 Wire Length I Voltage at EOL 1 Circuit Total Alarm Total Wire Size 69 200r - 528 00r._528 138 0 935; 14 23.45473248 1 4441 Wire Length Voltage at EOL Circuit Total 307 22.51884781 9351 CALCULATIONS TO NEAREST EXISTING SPEAKER CIRCUIT TO NEAREST EXISTING POWER SUPPLY S2-1 S2-2 S2-3 15cd 15cd 15cd TO NEAREST EXISTING J DATA LOOP D S1-1 S1-2 S1-3 30cd 30cd 30cd D,I -0 FIT -Ml 214 ITSMI IHT-RI S1-4 30cd SINGLE LINE DIAGRAM S2-5 S2-6 95cd 75cd EOL S1 EOL S2 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MINIMODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE MONITOR MODULE TO MONITOR KITCHEN HOOD. > EXISTING TENANT JUNCTION BOX. 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE r. 0 Raaaaa Cr CO w ~z co o07, Z o�z C(Qw� CC LT, '2(2 L(SI ck) CI) cc 8 Q o— W rn U T74( 1- N w I -- U 0 cC 0 0 w z w J z can Z O J U w C!) >- C) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:10/ 17/ 14 BACKROUND PLAN PROVIDED BY: ,0B NUMBER: 10464-1} SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ( 27 ) 0) / v SPEAKET1 OIT/ I / / TO)NI REST /EXISTINDATA/LOOP EOL S1 • ; S1-4 30cd ,/ 2 D / 2 4SNTIEAIOR.727 :1,, / ROWER SUPpLY • • '''' -•••"" '''' fi I r .• • (' ' 1161E:1-- PANEL pm.rfrrrnt,a HT -R] 1 Ep,, ..• ...... •1 „...,..,... .1., ., ,______, .. ! SEE i 1 II KITCHEN i 1 I " I. 1 DRAWINGS II, • L. ........a1.1.7.7.:, , 1 1 I ' • , 1 : r I S—c D6 • S1-3 30cd KITCHCN 6 (112 • i i, , .r,. ‘• 1109 ) LI 131 i. re•Di•Vii, • . r .`. 5(ii 1(. 0 0 -.741 1;17,1 I , ( 113) 30cd • S2-1 s; • „,.,; ; •!.:•;:frr.r..:••,r,r's,"„•;",f..11 •••••••• ( •. S FIRE PIT —, ( 103 c104,) f I k—k••ri )) S2-3 Dzi 15cd , -1 — -; ( 117 ) , ==.:1 FIRE Kr (1o5 \, ,....—. \ :::::'1,\ •fre„ -1 V:...2:74. i r/ , ...)1 l'1., „•:•••••‘ . 102 „ /‘ / \ • ,.•;•••' .e/r. 7 2- '” CI/, 07 11 ‘'/' •;" • \ • 7' E102 ""3.••• • • \.• • • • , I \ WESTFIIELD MALL !ENTRY • j r ( • / I I i ( 101 ,) I I ;vs, HOST STATION -•\• „tr,d ) • „) ;•z' K\ !!_/•)2 EOL FIRE PIT :;;P2 ,•':/1P)c\ , I / 1•••:",rrzr , ;,• 11 ,„ v „ >n, `,-,<<", , ! \„,;;:i:<•,,,,,;:,,,,,,,,,,, !,‘ • ,;;',,/' (-:,'," ,„............,, ,,;• ( E100 ) •\•:. `'s ',.. \,,,',,-'\ '''' ..- " .... ---- •••:, '-\ -,,-; , ' -if', ..... .... ... ..„. ,-;"„5,,, FIRE ALARM SYSTEM PLAN / FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MINIMODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE MONITOR MODULE TO MONITOR KITCHEN HOOD. 4> EXISTING TENANT JUNCTION BOX. Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: (.5 m o DESCRIPTION SHOP DRAWINGS DATE -4- ,_. .., N s., 0 ... 2 <<<<< 6ALE: 1/8"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:10/17/14 BACKROUND PLAN PROVIDED BY: %0B NUMBER:10464-1i 1 SHEET FA -04 -4- L. 1.1 L- 0 1 ! I .:;!!'4•11! • ..H.,'!!1•1:... SHEET \UN/I3E SHEET TITLE SHEET INDEX CHA. THAI FIRE ALA. TUKWILA, ni,it11 .1! r I FA -01 SYSTEM I \ FO 1\AATIO\ FA -02 TYPICAL DETAILS - WRI\G A\ D V 0 U \II\ • . FA -03 FR ALAN/1 SYSTEV FLOO PLA\ FA -04 SYSTEM CALCULATIO\ S GE\EAL), SE SITE PLA\ 1 0 Without Comments As Noted in Red Per The Attached Letter i nese plans have been reviawed by The Tukwila Fire Prevention Bureau for i.-:or:.foirce kyti-i current city standards. Acceptancr.: to errors and omissions wK•ch vio!ations ot adopted standaros and oraineres. T. r.-.LIspc.slisiby for the adequacy of desiqn w'iti-f the designer. Additions, deletjoill.i. or rEl.,,iSiOri• t theSE"; =wings a - this date will void triii_acc€::pi2nc.,-e P,nd will reeuire a NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. E DESIGNATION SCHEDULE resubmittal of revised drztwings for subsequent approval. Final acceptance subject to field test and inspection by 4 The Tukwila Fire Prevention Bureau. Date: ‘4,04444,44a...i451.4.1 By: tUKWILA FIRE DEPARTMENT Please call: 575-440Z and give this job No. 0 g- F - I and exact address for shut. down or restoration aporovel3 SHIELDED WIRE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION . NUMBER OF CONDUCTORS SIZE TYP. COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TV/0 #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD *12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR REM (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDIO ,TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART • NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE . DIMENSIONS • AREA • TWO 600V #12 AWG . THHN/THWN - . : ; .244 0.D. .0467 TWO • 600V #14 AWG THHN/THWN TWISTED - .210 O.D. -. .0346 TWO CONDUCTOR 300V •#18 AWG FPL TW CABLE .156 0.D. : .0191' •CONDUIT -FILL . • CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE.; ' . • ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM • THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. ; ; : ; L , . CONDUIT SIZE MAXIMUM FILL . ' . . 1/2" .12 SQUARE INCH , • 3/4" .21 SQUARE INCH . 1" .34 SQUARE INCH . 1-1/4" .60 SQUARE INCH ; • :, . •. . ,.. _ •. , 1-1/2" • .82 SQUARE INCH . • • 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. : TO BE GROUNDED'AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH' TAPE AND TAPED AT END ASIAN BISTR. M SYSTEM ASHINGTON ..GENERAL NOTES FOR SIEMENS SYSTEM •!•'. !!__ DO NOT INSTALL ADDRESSABLE. INITIATING DEVICES UNTIL PREPROPGRAMMED WITH DEVICES ADDRESS. ! H!;:t 11 1. NUMBERS ADJACENT TO DEVILS*BOL.. DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BETE SCOND. DEVICE ON ADDRESSABLE LOOP H. • IT RO'LARITY SHALL BE OBSERVED. 2. DETECTOR AND AUDIBLE CIRCI, 3. AUDIBLE/VISUAL CIRCUIT WIRItG 11.'SUPEr.NISED. NO PARALLEL BRANCHING IS PERMISSIBLq! • 4. INSTALLATION SHALL BE IN SIC111:CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NEPA 72, Lc1ALPDE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS UIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS 10),BLE, • FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMEPfS CRBERUS DIVISION. I 1r 6. DETECTORS SHALL NOT BE M UNht IN 'DIRECT AIR STREAIV OF AIR SUPPLY UTLTS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN . ITH RESPECT TO CO \IDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLORIODEdi' CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR ..FilUTOE IDENTIFICATION. 8. INSTALLING CONTRACTOR SH41:1;01TURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PO PC)$ES. ;1k 9. FOR ADDITIONAL INSTALLATIO INISir, RUCTIONS: REFER TO CATALOG CUT SHEETS AND/OR INSTALLATO I INSTRUCTIONS. 10. THE 120vac POWER ELECTRICL WQRK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLD., 2 i r:ND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.Z ,2: liN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SAL Nit)T BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRELAF1 TECHNICIAN. 11. ALL HORN/STROBE AND SIR() E Ei,E VICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW L.,' ROP'PED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONRg HAIL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CI,1 14. ALL. 120VAC CIRCUITS ARE FR;0 GENERATOR. CL • I WILL BE ON THE RECORD DRAWINGS SET. 1 EDICATED CIRCUITS FROM' THE EMERGENCY 15. PER NFPA 72 SECTION 5-31 3IDETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP' QFicALL TRADES IS COMPLETE- AND FINAL. EXCEPTION: WHERE REQUIRED BY .4HE *AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEENI.INALLED PRIOR: TO FINAL CLEAN-UP BY ALL TRADES. SHALL BE CLEANED CR ',REPLACED IN ACCORDANCE WITH NFPA .72 CHAPTER 7. • . 16. WIRING .SHALL RUN CONTINUOkS F130M FACP TO FIRST DEVICE ON A CIRCUIT . AND :THEN FROM DEVICE 'EVIE .WITHOUT SPLICING IN . PULL' BOXES OR „ OTHER BACK BOXES OF DFF.i4RE Ti;, CIRCUITS. 17. ALL WIRING SHALL' BE METER4,LID sAN.D TREE OF SHORTS: ETWN FINAL EQUIPMENT1TRIM. RIFIED JO BE CONTINUOUS; FREE:- OF: GROUND , ONDUCTORS AND OTHER CIRCUITS PRIOR TO • 18. ALL CABLES SHALL BE MARIH • ;-.,;1 fIRE ALARM EMOTE ANNUNCIATOR 1;j'. • ll;EMOTE BOOSTER OWER SUPPLY IliNTERFACE MODULE ilWITH RELAY , . ;1:1D1or'.U.: AL INPUT , ,11-NTERFACE MODULE 4CONTROL POINT VODULE • 431311 • PBA -11,91 A•vh ' s MOKE DETECTOR HFP-1 1 ' W/ SIEMENS :(ADDRESSABLE -PHOTO) DB -1•1 - BASE ?Ariql ITUCT SMOKE 1 ,':'.•:bETECTOR / • HEAT DETECTOR 1 ly'(ADDRESSABLE) :e FIRE ALARM • 11 p PEAKER STROBE (CEILING MOUNT) FIRE ALARM iii1.15PEAKER STROBE I l'(,YifALL MOUNT) • • IPRE ALARM TROBE :4CEILING MOUNT) EIRE ALARM tSTROBE ;:WALL MOUNT) 110RE ALARM ITPEAKER Ill(CEILING MOUNT) HRE ALARM 5PEAKER , (WALL MOUNT) 4S BOX W/ 1G RING RELEASE/REVISIONS m uJ DESCRIPTION LLJ 0 z z SHOP DRAWINGS FOR AHJ 0 N 11) 4S DEEP BOX W/ 1 -1 /2" EXT. 4S DEEP BOX W/ 1 -1 /2" EXT. 4, -JUNCTION BOX 1RNISHED BY SEHERS • T RRLICABLE 0 CC (f) co fY co LLJ Ci") < Z 2Z Ill cc 0 O- W (/) Z W • CC ocn 11, 0, - cc co u_ 0 T- . , INDICATED ON FIRE 'ALARM :;RISER WITH' •A PERMANENT LABEL AT ALL.1,':f,EVIC-S, ; JUNCTION BOXES .ANIX:FACR. :•' • , . THE ELECTRICAL CONTRACT° SI -ILL CLEAN ALL DIRT. AND DEBRIS. FROM THE OUTSIDE AND INSIDE OF THE r FIREV-ALARIvL; BACK' BOXES AND JUNCTION BOXES /WIER :COMPLETION- OF T -RI • 20.. DETECTORS 'MUST BE RATED10 kEMPERA TURE.: IN THE ENVIRONMENT IN: WHICH IT IS :LOCATED. • 21. ALL WIRING .BETWEEN FLOORS SHALL .BE :LOCATED IN :CONDUIT.. 22. NFPA 72 2002 6.42.2.2 'ALL 1-14'S OF CLASS:'A, CIRCUITS USING • P.HYSICAL CONDUCTORS (G:jMET4ILLIci OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE i.04T0NG KND RETURN' CONDUCTORS, EXITING FROM AND RETURNING TO TH0.1C0NTR0L:PNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. :THE 'OUTGOIG AND RETURN (REQYNDANT) CIRCUIT CONDUCTORS SHALL NOT BFON IN THE :SAME CABLE ASSEMBLY. (LE; MULTI -CONDUCTOR CABLE);: ECLQURE, OR RACEWAY. 23. , I NFPA 722002 A.6.4.2.22 4G0L OF 6.4.2.2.21 IS: TO PROVIDE ADEQUATE SEPARATION BETWNd THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED1LT0 HELP: ENSURE, PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE.1 THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PH.1$0 WAMAGE IS 305 MM (1 FT) WHERE :THE CABLE IS INSTALLED V(lfiCA Y AND 1.22 M: (4 FT) .WHERE THE • CABLE IS INSTALLED DATE 5/12/08 BACKROUND PLAN PROVIDE! BY: ". • tet 4 ,- •Jr 1 •,._, EOLS1, 10,86V EOLS2 18.49V -- D 4 --zcZI. ryys_11-2.7 [MT:CAL ROOM ELECTRIC:45.i PANEL S29 r-',474m7-FIFFR;;47,7,77:74.17.7;••,:: • - o '•••4; 75 [21:!:;4AA I2S'2YEsimicraram-nr.1 Nt. C 5 2S,2V 30 --------- - --- N \ \ El \ • • \ 1, .7 924/CE 919534 2. (.. ) 4, •<••,• -7.4•" )• \ \ \ • • 1'.5../%Y--' /. `• ...4 7. ,::":,...1'r-,..” \ 4., . ' ' , 4.-‘1:-.,c! ::' -- \ ,../ ;;•-• .7 7:47 \ '''.," .. - .'.4.:;:t,c <.--- '\-:,> • l':'',5---' ,7,-.5t':'Y \ „ \ \ S.:.• -.5" \ \a/ ''''''... 7.!''' \ ''„ \ \ 7 • \-ei\ ‘.4.:;.-..,,-;:.7--: ,...-:: •\ \''1;s:•,:Lf„,..ii.,./.,..v... ,•-•S':::r:;:77:':,..".":7'‘5:;;°C.::.7..\L.:\\-: ' i4-): '. \ •-• N:',P'A \--'"" ',': -I'::II. -.,,.--49A,k...„.>;:„ •,••,3•‘,•\ , ..,.„.;,,.„...„0, \ : • •i•t,,,\.,, \ ..•.-:, .„:•,• \\,--•<. • •,..- . - -•,••\--- \ \(.:- ....!, -•'..i.,-- .••••iy,'„,„):—.4---- • s',. ' •‘-`\‘• ...);•,,,,,;, •-• 7 l•-••:v.-"=:,c,..A.---.--\ ••••L •,,„-.-- :.,K,r.,...0-- -,..;.•',..f - --•-• y L.,i • 1 •.• . • ----------- -- - ::, 7.4 \ \ \ 7'4- -- •-<:-• \ 7' \ \ \ \ ..>-;;?" \ \ ,,,,. .„. \ \''.\ 7 \ .4.-' \ \ \ -.'‘ , \ \ \ \ .\-.7"29 >7>' 7 \ .x.' \•).:%'. 7 \ ....". \ • \ \ ..., \\ ,,,..r... -\&-‘r\ :$ - -54 \ \ \ \ \ \ ....7\ \ \ „7 ...:: 7 .>:' .7 \ \ \ ....5. • \ • .N:77 \ \ „.. \ „: \ .....2-2.7 \ 4 ,< \ \ ><\''' 4 .2 .7" \ \ \ 4.4'5 4-:'< \ \ 4?::' 2S,2V 75 \ \ \ \ \ \ \ \ \ \ \ \ \ \ •\ \ 7 4 , A 7 , A, • • -•>„ •,:tkrt \ \ \ \ tt: Th ; • i I '• . • ,• • • I• . I s 0 FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. •:' •.) RACHA THAI & ASIAN BISTRO WEST IELD SdUTHCENTER IVALL DO NO I \ST L ADDRESSABLE NOT DEVICES UNTIL REPOGAMMED W DEVICES •ESS. RELEASE/REVISIONS TEL. (206)• 622-65/4.5 REV. BY: - z DESCRIPTION SHOP DRAWINGS FOR AHJ - DATE o -••...., N ',... I') g <J<<<< "ALE: 1/8"=l' DRAWN ,BY: LANDERSON DESIGNED BY: R.VEZZANIL DATE:5/12/08 BACKROUND PLAN PROVIDED BY: • • • : ; ! Copyright : 2006 by Guardian Security Systems, Inc. Al! Rights Rsrvedli,. NUMBER:54537 SHEET FA -03 ic• ELE::: TRICAL IRM IKIDS FOOTLOCKER 1200 d-.3 0 LOrI•DINC -1 NORTH 0_ C) : : I 425 LU C) 1215 rl 201 •uJ c_) • [1235 I (J-) 4 (:_[L:(r(1KE: CIORY R3 1.:";.r • RASHA THAI WESTFIELD SOUTHCENTER MALL SCALE 11371' • • ! • 1 1 ; • 1. ••• ":•• r ' • RACHA THAI ' i .,! .. . RACHA THAI SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations J FACP ADD ONS DESCRIPTION SHOP DRAWINGS FOR AHJ DATE 2 N. c Lo Current Load: Standby: Alarm: Current Load: Standby: Alarm: '. Deice Type Qty • Amps Total Amps Total Device Type Qty Amps Total Amps Total Nattgappfutt Cinetki _ HF P-11 0.0022 0.0022 0.0023 MainPRIEp::RArIlIfFERWAL ,,,m.. ,i : 1 0.03 0.03 0.030 0.030 ,, AD2-P 1 0.0635 0.0635 0.064 0.064 SET-, Ogerrt UPENTIGTAIODO 1 0.064 0.064 I. HTR -R , 2. 0.009600 0.0096 0.021 0.042 °? "r:,."""'E ''''' R.. " SET--- 3 0.098 0.294 . HTRI-D 0.001600 0.0035 SET- _°_,jI . .2)•fm -It 1 0.175 0.175 , SET- Dv) ..,1 0.233. 0.233 I•I ! , . ________I • PI SETiI 7 MI 0.318 1. SET- 0.318 0.318 : SET-, INCHEivi 1 .. .,:k,I........ut 1 filj.L a j MN:MLA • 0.445 . .. , . ., . • , . . , .. .. . , , •. " 0.0731 Amps 0.106 Amps ZR -MC @15CD 0.064 0.128 - ' --- ZR -MC @30CD . 0.098 :1:I ., I! Standby Current Load: 0.0731 Amps . For 24 Hours = 1.754 Amp -hours HCP 0.0015 , • 0.03 Amps 1.242 Amps :,!!! Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours , • ,. :, Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours , 25% Derating= 2.204 Amp -hours Alarm Current Load: 1.242 Amps For 5 Minutes= 0.104 Amp -hours ' • Total System Current Load: 2.204 Amp -hours 25% Derating= 1.030 Amp -hours , Battery Pair to be Used: 12VDC Amp -hours 7AH • • !..:,., .! ••• . ,•! ! ! • , .,••, II • .1,, , ! . ,, • • , Total System Current Load: 1.030 Amp -hours , • • •,! i :• ,,, . 1! Battery Pair to be Used: 12VDC Amp -hours 7AH • , • Notification Appliance Circuit Detail PROJECT: !WESTFIELD SOUTHCENTER MALL. • • ..• . _ . Panel: [RACHA THAI Wire Resistance • O. •• •, ' Date. May 12, 2008 CURRENT TOTAL=11294 ciRcurr:si QTY • Device Type Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 0 1SET-MC @l5CD 64 0 Total Wire Resistance ( R ) 1.36 2 . 1SET-MC @30CD 98 196 ( WL *2 ) * (Rift) 21SET-MC @75CD _175 ... . . 0 . 1SET-MC @110CD 233 0 ISET-HMC-C@115CD 0 !:SET-HMC-C@177CD 318 445 0 1SET-HMC @135CD 318 350 0 0 0 0 Total Device Load, Amps (I (Total Cct Load) Voltage Drop ( E) (E= I * R) EOL Voltage . • - • 0.55 0.74 19.66 0 !SET -HMC @185CD 445 0 (20.4 - E) 0 Z- MC@1 5CD 64 0 0 1z7nac@3oci) 98 0 .0 ISET-MC-CW@110CD . DEVICES= 4 233 TOTAL rnA= 0 546 12 210 19.6570032 546 CIRCUIT: l S2 QTY ;; Device Type. ; 1 1SET-MC @15CD Alarm Current • I - 64 9. 1SET-MC @30CD 98 Alarm Total Wire Size 64 Wire Length Voltage at EOL Circuit Total Total Wire Resistance ( R ) 2.07 0 1 1SET-MC@75CD. @-116615 0SET-HMC-C@115CD ... SET-HMC-C@177CD . . . 2S2V 2S2 V 2S2V 2S2 V 30 15 135 30 2S,2V 2S2V 2S,2 V 30 30 75 EOL1 STROB EOL2 STROBE 15 •=L-2 S2 V cD-2S2V • S2 V FA -BOX B,', • FAC P] PSI RISER DIAGRAM 0 1SET-HMC @135CD 175 • 233 318 445 318 175, 0 0 0 0 ( WL *2 ) * (Rift) Total Device Load, Amps (I (Total Cct Load) Voltage Drop ( E) (E= I * R) EOL Voltage ...... . 1 ..... @185CD .. 0 I4-MC@30CD SET-MC-CW@110CD DEVICES4 CIRCUIT:1S3 445 64 98 233 TOTAL mA= 445 64. 0 0 748 (20.4 - E) 0.75 1.55 18.85 12 • I! 18.8489472 • -748 SYSTEM CALCULATIONS _ _ _ • Copyright 2006 by Guardian Security Systems; Inc. All Rights Reserved,.: RELEASE/REVISIONS REV. BY: z a _ DESCRIPTION SHOP DRAWINGS FOR AHJ DATE 2 N. c Lo 0 Er F - 1:;j §:jj za)c77 ogt WQ cc w H (9 z z < 2 w- cri 0w • w 00 w T -D CC 1 -- CD ›- CJ) 6ALE: 1/8"=1, DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE: 5/1 2/08 BACKROUND PLAN PROVIDED BY: J.CiB NUMBER: 54537 SHEET FA -04 El Without Comrnerits CI As Noted in Red Per The Attached Letter -ire pians have been reviewed by The Tukwila Fire : •:ntion Bureau for conformance with current City AcreoC:Ic e is subject to errors and r;w>lons which ;lo 4)0 authorize violations of adopted and of �,:1.nr.:t;:;. The responsibility for the : uacy of design Cotally with the designer. • fi ions, deletiom ro.ii-ions to these drawings after Th; d; to will void ri••sl ..,i..•:.e tante and will require a I'; •l..tbrnittal of reviser.: cl .,:•0)vinlgs for'subsequent approval. •Final acceptance alojecr'o meld test and Inspection by The Tukwila Fire Prevention isureau. Date: /0-��-��J By: ) i RETAINER STRAP. WHERE REQUIRED -IN SEISHIC AREAS Y • tClt 1LY FIRE WAR -MEW ! � PTease call 206-575.4407 and giV `this Fir Permit No. a• nd exact address for shut down or restoration approval. z 7.:"i,YAsF.;G"Fri1771,"S1Cr4r..X'Y.�k."t�'fi �,"�",'tltR':%i'G'"n"'"7•5tl !N,.,'a^t•^"x7"7"3R£'"'"'"CSi:�.,#»d l�:�#.iti�,�`_�,x�{tY4'k, am �.i,,;�i�C'�.r��"',,rnY^'"Tri'"�"S�,ra�:. Ad Arer-AAetArf/rrAAtt#rAdrrd0g°Ael.A d,AAar k r�s:x�e�,�.:� u�•.z��.s�«a.mrsr.��x,yrs:�aaa?aa�nx,c7au>=�,�,r,�a.�sr�awn;znecrsrs,asxra,.+v^�s:*an;o^zrsx•Mc^,�aM,r�a:.�zrx;,s:r�,:..^^7�.,m, arr,^,:s!�x....�a t`zr�tzx �r:rs�xuxttct5s 7e7^1.30;eax lI ihr 1.1 molt aziI trinVITIr ODIFYEllIVITMEMIn v et ,51(\k) AtkpJ 1.0 J. 'PEN TO ST` TUR i J.E +12'-6" AFF 1.1:1:1:1: :.:1:1::1:': '• •1:1:1:1• • PROVIDE UP LIGHTING (4) AT BASE OF DECORATIVE METAL TREE SCULPTURE • 1:1:1:i:1: 4:1:1:1:1:•' • 3:1:14:1: 13tU' :f • TOP BEAM/ C-CLAHP WITH SET SCREW 3/6' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS. Multi -Port Bracket FlexHead Sprinkler Drop Corrugated stainless steel hose with stairiless steel bral availble In 2', 3',4',5' & 6' legnths . • • • Adjustable Hub "q411.11111.11.1..111 I „ FLEHHE, Flexheadr om►Yierciai Ceiling Unit T -Bar Gelling Installation • Model #2024,2036,2048,2060,2072 Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart \ct C l� •1 o E — Existing uprights no change o 9 — Add Reliable Model G5-56 Quick Response 165° Concealed Pendents I/2 x I/2 (white) o 3 — Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 (white) o E — Existing pendent no change 9'-8 3/4" y -DEFERRED SUBS ITTAL +20'-0" AFF WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS John J. Abel 9760 -0591 -CG Level 3 o n Fire rotection, Inc. C" +� NFPO'4 1s RED CEDAR ROUGH SAWN BEAMS 2'0" O.C. SEE STRUCTURAL REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0" 0 2 4 8 :RQWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113. PH. (425) 481-7669 Expires 1...2/31/14 1 Si n ure r Moctezuma's Restaurant & Tequila Bar 1150 Southcenter Mall Tukwila, WA 0, 21.1`-1 SCALE: 115 . pA1D CCT 212014 TUKWILA FIRE 203— 7":;) J TO EAST RISER ROOM • • • 04, AZ 44, .‘ 27 NEW WOOD CEILING PANEL - NT: /7 A.F.F. ----- g O c°o i c/ r �4k - AL1 Racha Thai Kitchen Remote Area: Kitchen #1150 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS OH Group II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM / Ft' for 900 Ft' SPRINKLER Reliable Model F1FR ORIFICE 1/2" KG 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 281 GPM @ 62 PSI ' Ai time of Design 10'-0" CLG.=40% AREA REDUCTION CORRIDOR (EMPLOYEE ONLY( .,1M1 . i_��� ,I FS! i i ,fit, /y�5 s1+ j i v`.: M1.y EEZER-I".']'.11%C4_'�+�, -lt Y2-_ 1 0 4'1 1-3'/fi O DINING (I roe -(1). FS 1' 2 1210 B423 tL ELECTRICAL ROOM EXISTING HEADS TO REMAIN N. NEW QB CEILING ti MT.BAFF WOMS WB CEILING SERVICE STATION 1 o �tM1 r- O� RAI E MAII .SPH El.L4 11121 IUP 8".70 15 f• FS i73 4430 1 i V12X:lib /.- t, (C=1 --v:') •FTROT NOII1*IERS 7-1'/2 j CEILI(it'. r.8'AF F. • I V`f ii 2,41 AI, L +Alp`302 `v V,Y GER STANUCP I' .: c1r,f3 , 12c nINING 1 (Ni RILING .MAF F. RILING RAISE MAIN LIP 8" TO 15-2 AFP .. AT THIS POINT ..-_...._ EXISTING ZONE T5 4- MAIN 14 4`i/ 13X35 (C:=1 -v -i) =: .,✓ Way F F.7( ti B4 4347 r^t �,1 C.,1:301 1,,+`+ STATION 2 7-3 , �2-R1-% 1 7-0 /2 8-6'' <>> Vi... I "� ' 1, 4."t '? `;,� t. C ?..1 } I .. t,_: `';6L, • -'."-- SE MAIN 4P 8" TO 15.2 AA�I'll Ilil`14i''�'j``Erl_ i'..'-.., �nJ` l� D. B44, ITC) _....D�ySL * ,. fjt'/s 177.3 1-1'/Ag 7-0 9'h li.F. • , .' i. n )'`FSS-� �1, BAR _ _�. _.�_ff 'S .-'!° 6i t / 4-: F$ NEW GN ii `i Y\ `\ ,,rg2 0 -1 ti0 1 r X44. / •• 04,13A, ••4o, TS8. i'XM0 (T.O.S,+ 1 L L$4317 ..... • 11/2 '- '-�- REIi CEIL kjk)�. 8-10 f�.L6'ar 14 '�Irvf'•.f%��>� RECEPTION (ABV. ) W:. 0.X1 1 El- 8.u43ru......),;`;err "at. • ii) • (ADV.) C2 SPOT LIGHT FOR NT' 20' AFT,. C 4401(18 L\110i,49 OWER • • ) B44357 VU13X 5 W'1:_X 14 P=44303 vI� Rachajhai Kitcleri'`'4'� Rem6te Area: Seating,#11150 CALCULATION DESIGN SRITERIA: STANDARD NFPA #13'.,266Y. OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .443- GPM/FN for 1065 SPRINKLER Reliable Model F1FR ORIFICE 1/2" K= ":5.6,=, WATER FLOW INFORMATION`: STATIC 140 .. '• PSI RESIDUAL 20 •PSIr>�}; FLOW 10900 ;'GPM:. T: AT BASE OF RISER, SYSTEM REQUIRES:: 327 GPM @ 82 P$1 At time of Design 17'-6" CLG.=28% AREA REDUCTION Fire Sprinkler Piping Plan • 1/8"=1'-0" • n CO i{2 41, ' 7 -Th N. 1'30 EAST RISER ROOM (for hydraulic reference) General Notes 1. Western States Fire Protection to add new pendent heads, upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing in the kitchen and prep and seating area (.20 density used in calculations FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). Area reduction method per NFPA#13 section 11.2.3.2.3.1 was used. 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state &l local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are of desql� d for freezingconditions. 8. Existintire spriniKler system to remain. western States Fire Protection, will modify the existing system onlyin the areas of work. All other areas are not in contract and WSFP s not responsible for exiting conditions. FM [VII 11110111VAT NIKE LTEMLRRRAMCrE RESTRAINT LATERAL BRANCHLINE RESTRAINT N O r VICINITY MAP (Suite#1150) SCALE: NTS • Without Comments As Noted In Red Per The Attached Letter I nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subi✓'ct to errors and omissions which do not authorize violations of adopted stanaaras and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this -acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 3 --/S-d By: 17 I 11IT6aA=v treTCEORcamc=j-t,CL-.�•-;•®•••-.,_.-• avRTMAT RTN1,'MM2DUR rUKWILA FIRE DEPARTMEN% Please call: 575-440Z .-- and give this job No. 02 -- O 7 and exact address for shut. ,31-3wn or restoration approval Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 or email fireinsprequestftci.tukwila.wa.us to schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping, prior to hydrostatic test approval. I, Racha Thai Kitchen uJ W Catch Studio C.) ce U Martin Sokuiski ENGINEER: Catch Studio 0 0 SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL APPROVAL: City of Tukwila 4 -WAY EARTHQUAKE BRACE 3 5.6 Pendent IAN Chrome 155°F Reliable F3QR Dry 0 HYDRAULIC REFERENCE POINT 39 5.6 Pendent Chrome 155°F Reliable F1 FR SSP CONT. NO.: KS0255 HANGER SYMBOL 39 5.6 Upright Brass 165°F Reliable F1FR SSU DRAWN BY: Martin Sokulski BRANCHLINE RESTRAINT Total = 81 SPRK. ON SHEET: SEE LEGEND SPRK. ON JOB: 18 DATE: 03/18/08 Western States Fire Protection Company 7102180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUCXJEROUE/AUSTIN / DALLAS / DECATUR / DENVER / DULUTH /HOUSTON / KANSAS CITY LAS VEGAS I MINNEAPOLIS I PHOENIX/ PORTLAND / RAF ID CITY I ST. PAUL /SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 Rocha Thai Kitchen 1150 Southcenter Mall Tukwila,WA 98188 Fire Sprinkler Piping Plan SHEET FP1 OF 1