Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 1220 SOUTHCENTER MALL - MARINERS TEAM STORE - PERMITS AND PLANS
1220 SOUTHCENTER MALL ASSOCIATED PERMITS 14-F-022 14-S-024 14-S-019 13-S-024 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 1220 Southcenter Mall Tenant Name: Seattle Mariners Team Store New Tenant? Q - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: King Co. Assessor's Tax No.: 9202470010 Suite Number: Floor: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Secu rity Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City State Zip E-mail Address: Fax Number: 208.628.4990 Total number of new/relocated devices or sprinkler heads: 9 Valuation of Project (contractor's bid price): $ 2000 Scope of Work (please provide detailed information): Adding 9 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING NER OR ApHO�iI ED AGENT: \v1 Signature: Date: 2 I Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 JPZINUIF SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** ` King Co. Assessor's Tax No.: \ Site Address: `2,% cDou--NtAr C_�c 1 -Q. m,,,\0x\` Suite Number: Floor: Tenant Name: €a \e, 1 11[.li� i%�XS T&Vn SA-rwe. New Tenant? Q- Yes 111- No Property Owner's Name: \)\)es .e L YrIan krrna')# Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: tibMSCSi•\ Day Telephone: 1425 •'-) i• 7L69 Company Name: CztDY\ T(' *\f (\ Mailing Address: 12\3 City State Zip E-mail Address: Je. sc.o.pLjL-1-5YI-c? • C_ JY Y1 Fax Number: L/24 i / J.$(ogr Total number of new/relocated devices or sprinkler heads: C 2..t. ) Valuation of Project (contractor's bid price): $ 1\iC)- Scope of Work (please provide detailed information):_ S r 1�cn ,P) e, eN& ,(YIp 2 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: JeSsiC4 gsbi/San Plan Permit App.doc Date: g. 3. 2 Day Telephone: 6'2 •4 '8/ 721o'3 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Mariners Team Store 1220 Southcenter Mall Permit No.: 14-S-024 Date: February 11, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 %h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. 02/05/2014 17:07 4254818695 FAX TRANSr IITTAL CROWN FIRE PAGE 01/01 Fax No. CROWN FIRE PROTECTION, INC. MIEES 2.5.14 Fire Prevention Bureau Tukwila Fire Department / Al Demo Permit Number of 1'aucr (1nclrrrlirr« C'rn-er) Urgent Frlim Comments 1 206.575.4439 A%*/ 4k. El For Review 0 Please Comment 0 Please Reply Cristie Ogland PJJ:425.481.7669 k X:425.481.8695 Please provide a demo permit to remove (4) sprizilder heads that are in the way of the framing at the Mariners Team Store project at 1220 Southcenter Mall. The building permit # is D14-0005. Please let us know if you have any questions. Thanks - s ; ,NWILA FIRE DEPARTM T rise can 206-5754407 and iive this Fire Permit NO. and wet address for shut- down or restoration Koval. cERTIPICA"TE or wraPETENCY FIRE P'ROTEC ON SPRINKLER SYSTEMS P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.4811669 EX: 425. 481.8695 C TED O Without Comments Q As Noted In Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance :y subject to errors and omissions which do not authorize, violations of adopted standards and ordinances. Me responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after his date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to'fleid test and inspection by The Tukwila Fire Prevention Bureau. Date: 2 -f c- I `( By: 41,%-% A 5( SEATTLE MARINERS TEAM STORE FIRE ALARM SYSTEM ADDITION T c), W:it A, FIRE DEPA +, i Masse call 206-575-4;0? /T4.,4g TUKWILA , WASHINGTON ,this Fire Permit No. artd exact address for mut- down or SHEET \UN 3E. SHEET TITLE FA -01 SYSTEvI \FORv ATI O \ FA -02 TYPICAL WHI\G AND V O U \TI \ G DETAILS FA -03 SYSTEV CALCULATIO\S A\D SI\GLE LI NE DIAGAIV FA -04 FRE ALAfv SYSTEV PLAN SHEET INDEX NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the te:-stinq WISE SCHEDULE A\D CO\ D U IT FILL C HAAT WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKED D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKED P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKED S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKED S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKED V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKED V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKED I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKED CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2'' .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCLIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NEPA 70, N.E.C. AND NEPA 72, SPECIFICALLY SECTION 1-5,2,5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vaC POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WTH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 4 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP ® SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING ® D DUCT DETECTOR AD2-P W/ SIEMENS HFP-1 1 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 171,275sf Ea 2ESC0 IT RL U macys 4 LEVELS 250,407sf P UG W?WCOR 01 8 �yp mE BAIT ROSE 011 E? Of Of UUCHO BURRITO THE 1U% SHOP SHIRTZ TO C0 TINDERBOX BLO mmv 64 AV BA1 ❑ R i RECO IA CI.ASS gO �N B d fiTN SLYER k 0010 INVOVi"S I I KING COUNTY 110RARY COOIVA AN)N FVC, OOK 50+000 BEC60 ARS 2650' 050 Bx, Bronx SEATTLE MARINERS TEAM STORE #1220 WIRE DESIGNATION GENERAL NOTES SITE PLAN PAID FEB ® 3 2014 TUKWILA FIRE Pov 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 03 0 DESCRIPTION SHOP DRAWINGS DATE Z M 0 WM�+ LL 0 F- Z0�0 Q OQo) W O 2Z ~ CD w O O zz W � Z2I- CC cc Lu cc cm J LL TI- _ I Z 0 F 0 W F- N 4-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 /31 / 14 BACKROUND PLAN PROVIDED BY: Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved .JOB NUMBER: 7932-12 SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6011Z -1 DEDICA1ED EMERGENCY 111 NOTE FOR ADOIBONAL SPECIRCAIIONS SEE PRODUCT DOOAIINTAfON. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC ISDI✓,TI tiittisME wND TO NEXT ADDRESSABLE (+ DEVICE STIR' IF LAST DEVICE - FRON XLS CRITROL PANEL (+ OR PREVIOUS ADDRESSABLE DEVICE - O ° O GROUND ® 0 HTRI-R 0 O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C—CABLE C—CABLE 0 EIDE ORD N LL 0 00 00 II O PAD -3 00 NPUT INPUT TROUBLE NACI NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 0 3.6k EOL (-) (+) (-) (+) SPARE SPARE j SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (—) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 m P1 0 (+) 0 c m WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIRWITH SHIELD #18 FPIJFPLR RED (JACKET) *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O ° O GROUND 0 0 L_J HTRI-R (-) 0 (+)> TO NEXT DEVICE OR STOP IF LAST DEVICE (—) DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) + u HORN/STROBE OR STROBE ONLY U U HORN/STROBE OR STROBE ONLY U U HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32' F 0' C TO 100' F 3IT C) HUMIDITY: -9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR rioFROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) >-- DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) TO NEXT I I ADDRESSABLE (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX \ . ` SOSO ' PT erIr a 4 eine eie a ee t#?i`. JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT cED SMOKE/HEAT DETECTOR TO NEXT DEVICE CADDY BAR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS DATE r M 0 zaaaK< W O F- co Z 00 Q O� W TZ I— Q W o can wHo Z Z_ w 0_ T (i) I< CC cc QO� Q T WNL Lv L T � V , cf) J SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 /31 / 14 BACKROUND PLAN PROVIDED BY: 'OB NUMBER: 7932-12 C SHEET FA -02 Y a P ore i }. aaA' .c b„ "+`.�'Ft A.;:'�E Sv' .wdp �'.,'&: �''.i3i.C`A'xd "P`,�d;. § '«;';,` �E'}4 3„a✓., u.} %:�,".,4,dL .¢S{�``6 #3t 5 * t5't l£ �'. yf, l�� >S.',k':: ��(f3P S.n; ' , s'•^'# %�'` a'(. y��.' m-'>£'� �/..,.,'£'< gid'.:}"�'?:,y'fs�y.x 3•rt`5��. �.:'h. �.�G»}+,:�',��° ,�w.ii:. <., .<:tiex'R `('ib''���i'N'rf '.'.W`x...+..+n�^"Y'�35�„:)�i i^&"}':.F.•.:a:<,rd<� .. k: K' ... a.: 5 A'v �,. },k.t.."2,g>;E'�'+.': ..}'�.e Y.:£:;¢.`::'So,. , :°T', ..,3 ,>} SHOP DRAWINGS 1-1 U Current Load: Standby: Alarm: W CD Device Type Qty Amps Total Amps Total Amps HFP-11 2 00022; 0.0022 0;0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 0.030 HTR -R 2 0.009600 0.0096 0.021 , 0.042 0.0875 ZH-MC-CW @30CD 14 0.131 7.11 -MC -CW @75CD 2 '0.222 al -MC -CW @95CD 0.0731 Amps 0.106 Amps Notification Appliance Circuit Detail PROJECT: SEATTLE MARINERS TEAM STORE Panel: EXISTING PAD -3 POWER SUPPLY Date: January 31, 2014 Wire Resistance 2.58 CURRENT TOTAL= 593.00 21.1 -MC -CW @15cd 87; 01 2FI MC=CW @30cd 'l31' :524 2H MC -CW @75cd 222 01 0-C1ni '95+cci 292......, _.:. ZH MC-CW_@115cd 3711 0 ZR MC -CW @15cd 63 e9 DEVICES TOTAL mA= ` 5931 14 j 310 j 23.051 593 :Total Wire Resistance (R ) 1,15WCe Load,Amps (1; Volta a Drop E EOL'Voltage 0.95 :23:05 SYSTEM CALCULATIONS S TO NEAREST EXISTING POWER SUPPLY S,S' S,S' V S,S' S,S' V S,S' D TO NEAREST EXISTING b DATA LOOP EOL S1 S1-1 30cd S1 -2 30cd S1-3 15cd S1-4 30cd S1-5 30cd FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 w w U) LU J LU REV. BY: DMG 5 } ' .. €Sx �.ss4 '>. $ .,€ .. , Ara. <�. a ,' ..z, ���. " j✓ - r .:.; � r,Q€�� �:. ' e :ki a,�i §-� }}, i�. r �¢° y[■� M ''�i �I .iSr j Y.. �y(1 1 < '!;' £ fr ° }$gy w e,-0;€ 1 p �"" �,p rF F �,�zr: „��, Yt� "2? ;.yy�y��'e � � �Z, � �.,: �..13,�■�#%y a■y,��I$y+}�,: 'd�� dx;,i'Y'< � tI�M: � �, "a iM\M^�i�l��",,.%F. SHOP DRAWINGS 1-1 U e W CD Device Type Qty Amps Total Amps Total 2 <<aaa Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW :@15CD:` 13 0.0875 ZH-MC-CW @30CD 14 0.131 7.11 -MC -CW @75CD 2 '0.222 al -MC -CW @95CD 0.292 al -HMC -CW :@115C© < 0;371 ZR -MC -CW @15CD 21 0.069 1.449 ZR=MC=W .'@'l SCD 0.064 0.03 Amps 1.479 Amps Standby: Current L.:oad; 0.03 Amps Am FFor24:Hours = ''0.720 rnp-hours i Alarm Current Load: = 1.479 Ampsp- FOr 5 Minutes= : ..0.124 Am ours, 25%Derating=. ; 1.055 Amp -hours Total System Current Load: 1.055 Amp -hours €x,, i�M�.(,} k Fy }!, (�,yx $ r"p((y s.;�wj�i ",r' a�.:i`drt<'',A;Y.; fit" >„N.'y■s�t■tk�' Y:'y "s"•`T.'S PF' ,.yfi,P. p3f*i x+ l t r�, J'`' V P Notification Appliance Circuit Detail PROJECT: SEATTLE MARINERS TEAM STORE Panel: EXISTING PAD -3 POWER SUPPLY Date: January 31, 2014 Wire Resistance 2.58 CURRENT TOTAL= 593.00 21.1 -MC -CW @15cd 87; 01 2FI MC=CW @30cd 'l31' :524 2H MC -CW @75cd 222 01 0-C1ni '95+cci 292......, _.:. ZH MC-CW_@115cd 3711 0 ZR MC -CW @15cd 63 e9 DEVICES TOTAL mA= ` 5931 14 j 310 j 23.051 593 :Total Wire Resistance (R ) 1,15WCe Load,Amps (1; Volta a Drop E EOL'Voltage 0.95 :23:05 SYSTEM CALCULATIONS S TO NEAREST EXISTING POWER SUPPLY S,S' S,S' V S,S' S,S' V S,S' D TO NEAREST EXISTING b DATA LOOP EOL S1 S1-1 30cd S1 -2 30cd S1-3 15cd S1-4 30cd S1-5 30cd FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 w w U) LU J LU REV. BY: DMG z 0 a_ SHOP DRAWINGS 1-1 U W CD DATE 01/31/14 2 <<aaa CC 0 w W C O J cn W Z -J o „coQ�� 0z_ I—�WaC �o�co U) i --c 0 cc w z Wim( ©C C!) I— E cco- Z ctc 0 c\I 0 Q J W CP U W F- C,) >- (i) CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 /31 / 14 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved \OB NUMBER: 7932-12 SHEET FA -03 Th) (5 TO NEAREST EXISTING S POWER SUPPLY TO NEAREST EXISTING S DATA LOOP EOL S1 4-91 S1-1 30cd STOC ❑a 1cd FUTURE BACK OF HOUSE WALLS BY TENANT CONTRACTOR. LOCATION TO BE DETERMINED BY TENANT. S,S' OFF CE S,S'-o CREAT RO DM 348 Si -4 30cd 7 ---- S,SL c 11 S1-5cd 01 30 FLOOR PLAN — FIRE ALARM SYSTEM CASH WRAP. LOCATION PROVIDED BY TENANT. 2'-0" A.F.F. RAISED PLATFORM NEW CHANNEL STOREFRONT SYSTEM WITH 1/2" GLASS 28'-0" 24'-0" TO-NEAREST-EXISTI POWER SUPPLY G y 4'-0" TO NEAREST EXISTING DATA LOOP s,s-- C FUTURE BACK OF HOUSE WALLS AND /-F DOORS BY TENANT g.i i r o 9'— Y '—Y TENANT <E3 9' — BY TENANT 22'-0" 9" DIA. 32 WATT EA. LIGHT FIXTURES PER CONTRACTOR. TYP. al N I1 FURNISH AND INSTALL NEW 2'x2' SUSPENDED GRID SYSTEM AT 5) _PENDANT LIGHT FIXTURES AT CASH REGISTERS PER TENANT —KA 12 — 0> SUPPLY AND RETURN GRILL LAYOUTS ARE FOR REPRESENTATIONAL PURPOSES ONLY. FINAL DESIGN AND LAYOUT UNDER SEPERATE CONTRACT 14 REFLECTED CEILING PLAN — FIRE ALARM SYSTEM 53'-2" 9'-2" FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. z O z_ U) LIT I— a LLJ U) O U) Lu I— U) N- 1,0 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m a DESCRIPTION SHOP DRAWINGS DATE M O o «a«« W cc 0 F— CI) 1/J ��,.z o OJo1— Wo¢� 2z V- W 2 1-0 >• cc w W = W Ou (/) ccs U - og < Q WNL Cr CV WT W Cn W cr 6ALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 /31 / 14 BACKROUND PLAN PROVIDED BY: ,OB NUMBER: 7932-1} SHEET FA -04 Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved J Design per NFPA 13, Ordinary Hazard Group 2, Retail - 130 Sq. Feet Max All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart TV ILA FIRE DEPARTMENT tali 206575-4407 ONO tfiiS Fire Permit NO. and address for 'iut- dow1 or restoration approval. Q Without Comments. • D M Noted in Red ' tr Per The Attached. Letter These plans have been reviewed by The Tukwila Fire :event—ion Bureau for conformance with current City ,ndards. Acceptance is subject•toerrors and IisslonS which do not authorize violations of adopted ndards and Ordinances. • The responsibllfty for the .,quacy of design rests totally with the designer. ..1itiOns, deletions or revisions to these drawings after is date will void this acceptance and will require & ;!submittal of revised drawings for subsequent approval: Ona! acceptance is subject to.lheld test and'inspectio.nby he Tukwila Fire Prevention Bureau. Date: `( By: RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD ROD PIPE SWIVEL RING o 2— Add pendent to Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 o 3 — Relocate pendent to Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 • 16 — Re -cut Reliable Model G5-56 Standard Response 165° Concealed Pendents 1/2 x 1/2 (on Flexheads) • 1— Add Reliable Model G5-56 Standard Response 165° Concealed Pendent 1/2 x 1/2 (on Flexhead) • 2 — Relocate Reliable Model G5-56 Standard Response 165° Concealed Pendents 1/2 x 1/2 (on Flexheads) o . 2 — Demo existing pendent TOTAL — 26 • N tzd- n • 5 24'-0" 4'-0" II • 0 co FUTURE BACK OF HOUSE WALLS AND DOORS BY TENANT 0 .0 v 1 N FURNISH AND INSTALL NEW 2'x2' SUSPENDED GRID SYSTEM AT 12'-0"A.F.F: 0 0 0 REFLECTED CEILING PLAN.. SCALE: 1/8" =1'-0" O : 'NOS t\b' 6 1. tm,tD,ttettAk ‘S �� kVe "D l %;64." har crt bcaczehi. EDLP rc.sk (a* nk or rtel tc1 ter 444.. iriA64)&ok t e 2.%);. re r eAt°s, Vet; e k Jrlie re w e d '�`I s Abe Si%cetrraM saitC;4k, 1wf qpo `af t'%$M.4 vtoa ,t d to 44441 • STEEL JOIST/TRUSS HANGER DETAIL NTS WASHINGTON STATE CERTIFICATE OF 1k Andover Park W. Family Parking LANDLORD WORK -• MARINERS TEAM STORE to 0 FIRE PROTECTION SPR NKLERE SYSTEMS °r John J. Abel 9760.0591•CG Level 3 Crow Fire Protection, Inc. ®® ®0 w a ature tree 114 for Southcenter Pkwy. CROWN..: FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 P11. (425) 481-7889 SEATTLE MARINERS TEAM STORE 1220 South center Mall Tukwila, WA 98188 PAID FEB —4 2014 TUK1A ILA FIRE • 'Z79z0 DATE: �'. 3, ly DRAWN: 1 SCALE: