Loading...
HomeMy WebLinkAboutPP - 1230 SOUTHCENTER MALL - PLAYLIVE / BAKERS SHOE STORE - PERMITS AND PLANS1230 SOUTHCENTER MALL ASSOCIATED PERMITS 12-F-171 12-S-121 LFZERM SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: \2C)_ King Co. Assessor's Tax No.: Tenant Name: Property Owner's Name: wer---5\---c\-eArk Mailing Address: Suite Number: 3 52. Floor: New Tenant? fa- Yes ❑ - No Pin• Corou CONTACT PERSON -if there are questions about the submittal. City State Zip Name: Day Telephone: 4 ) / - 7(010 7 Company Name: Cxnu....)ri kc=;._ ?ice eck \Un, G Mailing Address: c© 4i7DO X \ \2.1 ` Y \ Cl\ C f-& C t e 'P t."2.1 E-mail Address: P 1 CckP C y`d LAD y-i-� \ , co rY7 Fax Number: City L 17 ' 51Sga7 Zik Valuation of Project (contractor's bid price): $ 0, tin9, ,00 ^..AScope of Work (please provide detailed information): , \ (21-6 VleaCIS PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN WNER OR AUTHORIZED AGENT: Signature: �/ RC 1, CApi"(;$eDate: L1G/ I '� 3eSe-J*?)ObL n Sort Day Telephone: 2/2 '1-71g/' 7(QL 9 Print Name: Plan Permit App.doc 5/14/10 TFD FP Form 8 dilitt"144 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 12S 0 StiL,Joinc e -i- Suite Number: Floor: Tenant Name: l %At_ Property Owner's Name: Mailing Address: CONTACT PERSON -if there are questions about the submittal. Lik_skck.Q 1_L( New Tenant? ®- Yes ❑ - No Name: Ra, eao} 1‹-e Company Name: G- _*. rc>u:SZc w•, ��.,� Mailing Address: % E-mail Address: 01- � S City State Zip Day Telephone: C .O623S`l12 6g ( -Az le.� I.,tne.d-c iljz Se c rv-: �J S it kite ( LAA- (l 8134 City State Zigg w vh Fax Number: C.206J 3 (�gg2tT Valuation of Project (contractor's bid price): $ S/ b 0 0 Scope of Work (please provide detailed information): is -CI,rsaw i .ter .n-, 44-0 cJ241 1'4C5 N-- S (a -Ca- • PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: (k - c& - <� e Print Name: Plan Permit App.doc Date: 0o2/ l Z Day Telephone: Cz4,6") 3`t kr-LC $ 5/14/10 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: PlayLive 1230 Southcenter Mall Permit No.: 12-S-121 Date: June 12, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. 4 • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. (E) ( TENANT; LEASE Lai`=- (E) 2X2 CEILING GRID TO..: ilE"OEL"LOI.iSHED MGM HEADER TO REMAIN (E) 2X2 CEILiNIG CAD TO eE P6101 LSF D \- ADJAcwr TENANT SPACE - NO = .:...; 11416 AREA -\ (E) 2X4 TO (E) (E) MALL (E) LIGHT FIXTURE TO EE DEXXISHED • TYPICAL GF 2 TENANT LEASE LINE NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testiT'o. 1EN,N t LEASE (E) EXITE k . T0, REMAIN TENANT LEASE Ltt4 .- 1 h AftalliOftm IAYI1--mansmis imam tommausvL�I�I tom. ,ii �� .'*«'9t'-' 1,111 f�_ 41 I �E ' ly imammil ATP; (IOW irdf 114310.111 �im I�■■ '®®1111I1�1O�® 6TIli®.�Qk J �1m Af..I�1 IIII SPINIMINIENTIONIMINE ['' ill EN IRA wispLemi MINIM1111111iii11211111 ■■11llrMAILIl1hIIal ■■ MINI i®II►1 111111111111 IMMEREMMM MMEMMEBREOMMEL MEMEMOMMINEMEMMIAMMUM� ■■ I■ ■W MMEMENIMm ■■O■■■MROMMEq■��'MMEMEMEAM ME ■■■■■■M ■ ME OM 1111 ■■ ■■ ES ME®, ®■■■■■■■®®■MM ■ME■■■M'M■ ■■\ ■■11M O■® ■M■■■■I M'■� ADJACENT ..MANI SPACE - NO 1$ AA (E) GILTS LADE R TO REMAIN NORTH DEMO (E) FINLS AT TENANT STOIRFRONT AND NEUTRAL: PIERS ToP C>F BULKH 1i'-6"— EXTRUDED ALL1114M 1 -AK SHAPE ABOVE. ST TOP. OF STORSt�RONT 14.-001 _4l.UMIDI�1 USE AT HEAD 3%' METAL STUD F R 1ft G AND GIIII3 PAINT LEVEL 4 FINISH JM JAICENT 'TENANT SPAM MANT. LEASE LI (E) MALI.. COrND2 Rsl .REF-LECTED':CEILING .PLAN DOOM. TYPE DOOR STYLE SIZE W x H THK. DOOR MATL. HM,FR' TYPE; FRAME MAIL. . RATING HDWR. GROUP NOTES HEAD JAM THRESH MOU JFIC,A►Tlt OR FRAM ALL REQIa1t1TS FOR GLASS DOOM'WITHIN VACANT ef?ACE STAINS 'THIS CONTRACTOR TOP FINISH COAT >3Y TENANT PR 3'0" x. 10'-0 3!..44 ',1'-0" I/2' i 3/4" 13/4' 13/4" GLASS WOOD` WOO' WOOD WA WA N/A N/A. N/A HM HM HM NR. NA" NR. I2/A2,0' SIM.3/A2iD 6/42.0 1 2 443Y3i'.Y14TI5: ALUM: 2,3,4,5 6, 1, 1 FINISH FLO©R 0'-0"- ......_ TUKWIUA FIRE'DEPARTMEI;1T Please call .206-575-4407 antl) BOTTOM aF MULLION give. this Fire Permit NO. 1'-m' .. ___4 . and exact address for shut- down or res oration approy8l. DEMO (E) FINS AT TENANT' STOREFFRi/ONT AND NEUTRAL:' PIERS ilerr/4° . n w Shici<k -J s - Sk(tk a0A14. METAL STUD BRACING HACK TO STRUCTURE AS REQUIRED (E) BULKHEAD (E) STRICTURE 3%' DIAGONAL- BRACING AT 4'-0' O.C. B.O. BULKHEAD ;,5 Ill -0" SUSPENDED ACOUSTICAL CEILING TILE AND GRID METAL STUD' FRAMING MD GUS EULKHEAD 4" RUBBER BASE CARPET TYPICAL' I TYPICAL LEASE LINE TOP OF STOLFR+ONT �- "" _ IFR 6. ALUMNUI BREAK METAL SHAPE ABOVE STOREF=RONT TOP OF STOR MONT AWMINUM TLIEE AT HEAP 3%' METAL STUD FRAMING AND GWS - PRIME LEVEL 4 FINISH ALUMINLM TUBE FOR TENANT -SIGNAGE Trip 4 :: e�A ST WITH GLAZ WALL SECTION AT STOREFRONT 1/8 = V-0" METAL STUD BRACING I TO STRICTURE AS REQ (E) EULKHEAD REFLECTED CEILING PLAN GENERAL NOTES: L DIMENSIONS PROVIDED ARE PLUS/MiNUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING MD NEW DIMENSiOINS AND NOTIFY ARCHITECT CF ANY DISCREPANCIES 2. CONTRACTOR SHALL FULLY SUPPORT AND BRACE ASSOCIATED CEILING DESIGNATED TO BE DEMOLISHED PER LOCAL CODES AND JURISDICTIONAL REQUIREMENTS. SUPPORT AND BRACING SHALL INCLUDE ALL CEILING COMPONENTS WITHIN AREA TO BE DEMOLISHED, INCLUDING BUT NOT LIMITED TO, LIGHTING, SPRINKLER, DIFFUSERS FIRE ALARM ETC. 3. CONTRACTOR SHALL SUPPORT AND BRACE ANY AND ALL CEILING COMPONENTS AT LINE OF DEMOLITION, INCLUDING BUT NOT LIMITED TO SUSPENDED CEILING GRID AND TILE, DUCTWORK CONDUIT AND IIIRING. 4. AREAS DESIGNATED AS 'NO WORK 11418 AREA' SHALL REMAIN AS CURRENT CONDITION. THE SPACE SHALL MEET THE REQUIREMENTS SET FORTH EY LOCAL JRISDICTiON FOR A VACANT SPACE. SPRINKLER SYSTEM AND FIRE ALARM SHALL PROVIDE COVERAGE FOR THE VACANT SPACE AS REQUIRED. 5. CONTRACTOR SHALL CAP MD TERMINATE ALL EXISTING UTILITIES AND SERVICES DESIGNATED TO BE DEMOLISHED ABOVE FINISH FLOOR LEVEL AT ITS PONT OF ORIGIN. 6. CONTRACTOR SHALL PROVIDE REQUIRED SPRINKLER AND FIRE ALAR1 PROTECTION WITHIN VACANT TENANT SPACE AS REQUIRED EY LOCAL JURISDICTION. 1. CONTRACTOR SHALL VERIFY HEIGHT CF EXISTING CEILING AND STRUCTURE ABOVE. 8. DESIGN EUILD CONTRACTOR SHALL EE RESPONSIBLE FOR steMITTAL OF LIGHTING BUDGET ANALYSIS TO CITY OF T IJILA PER LOCAL JURISDICTION REQUIRE/MEWS O EFLECTEJ) CEILING PLAN KEY NOTES: 01 2 X 2 SUSPENDED ACOUSTICAL TILE AND GRID. GRID AND LIGHT FIXTURES SHALL BE SEISMICALLY BRACED PER IBC 2003 GRID SHALL SE MINIMUM6V WITH SUPPORT GUY WIRES PER MAl41 ACTURIes AND LOCAL JURISDICTION. SPRINKLER HEADS SHALL BE PER FIRE SPRINKLER CONTRACTOR TO BE LOCATED WITHIN CENTER OF TILES, TYPICAL. - USG - FROST CLIMAPLUS -Y' THICK STRAIGHT EDGE. ONO CEILING THIS AREA - OPEN TO STRUCTURE ABOVE. CONTRACTOR SHALL PROVIDE REWIRED FIRE ALARM, SPRINKLER AND ASSOCIATED LIGHTING AND m3 LAY -IN 2 X 4 LIGHT FIXTURE WITHIN SUSPENDED CEILING GRID PER ELECTRICAL DESIGN BUILD CONTRACTOR FIXTURE TYPE, QUANTITIES, MD LOCATION ARE SWOUN FOR REFERENCE ONLY AND SHALL SE COORDINATED WIN DESIGN BUILD CONTRACTOR TO MEET LOCAL CODES AND JURISDICTION. OMECHANICAL R SUPPLY DIFFUSER PER MECHANICAL DESIGN BUILD CONTRACTOR. DIFFUSER TYPE, QUANTITY AND LOCATION ARE SHOWN FOR REFERENCE NCE ONLY AND SHALL BE COORDINATED MTH DESIGN BUILD CONTRACTOR OMECHANICAL RETURNDIFFUSER PER MECHANICAL DESIGN BUILD CONTRACTOR. DIFRISER TYPE, QUANTITY AND LOCATION ARE 51401114 FOR REFERENCE ONLY AND SHALL BE COORDINATED WITH DESIGN !WILD CONTRACTOR ORECESSED DOW4 LIGHT PER ELECTRICAL DESIGN BUILD CONTRACTOR FIXTURE TYPE, QUANTITIES, AND LOCATION ARE SHOK114 FOR REFERENCE ONLY AND SHALL BE COORDINATED WITH DESIGN BUILD CONTRACTOR TO MEET LOCAL CODES MD JURISDICTION. OGYPSUM WALL BOARD SOFFIT MD BULKHEAD AT TENANT STOREFRONT. CONTRACTOR SHALL PRIME, AND PREP GWS TO LEVEL 4 FINISH.., O SUSPENDED LIGHT FIXTURE. - 4'-0' FLOURESCENT STRIP FIXTURE AT 10'-0' AFF (E) FINS MD PLYWOOD TO SE DEMOLISHED ALONG TENANT BULKHEAD MD ACROSS ADJACENT NEUTRAL PIERS HARD%, Yt. AR r.i MALL STOREF comPr--az-W2gliPagla I -'4gyetit T NAI�r �L.�Ej�S- MANUFACTURER L -SERIES CHMMELLC J I- STAMEN HoRtZtsTAL GLAZED SYSTEM,. -: ® ., . Witl ouut'Comments .As ' Noted in Red p Per: Tire Attached Letter se plans have been 'reviewed by The Tukwila Fire !!& ntion Bureau for conformance with current City ndards: Acceptance is subject to errors and - ,,il;-,sions•which do not authorize violations of adopted :3ndar6 and ordinances. The responsibility for the .iequacy. of design rests totally with the designer. • ,-iditions, deletion s'. or revisions to these drawings after this date w11I void mils acceptance and will require a resubmittal of: revised drawings for subsequent approval. Final. acceptance is -.subject to field test and inspection by .The Tukwila Fire Prevention 13ur • u. ,J I • Date: S -. ( Uy:! METAL en AND GWS ALM. STOFRIONT FRAME WITH CONCEALED DOOR CLOSER �- GLASS ENTRY DOORS - SEE SCHEDULE HARDWARE - SEE SCNEDULE ) LEASE LINE TOP OF STOREFRONT S'-6" • WALL SECTION AT ENTRY METAL STUD FRAMING PRIME LEvEL 4 FINISH 'ALUMINUM MAK METAL SHAPE ABOvE STOREFRCNT 3%6 METAL MD FRAMIt4 AND GUS - PRIME TO LEVEL 4 FINISH PROVIDE DIAG. BRACING AT .Top pToptipfRoNT WALL SECTION AT ENTRY ALUMINUM STOREFRONT FRAMING AND GLAZING PAID TUKWILA FIRE WES Southcenter CONSMCITON 11601 Wilshire boulevard, 11th Floor Loa Angeles, Ccilfonila 00025-1748 Telephone 310 478 4458 Faceknlle 310 478 4488 • S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 MEW= WAY SW SUITS 200 • szailit. WA 05108 4220 \ REGISTERED ARCHITECT SCOTT 11. SOWER STATE OF WASIMOTON WESTFIELD MALL AT SOUTHCENTER ISSUE Et U -I APRIL 11, 2012 ISSUE PERMITSET DATE: JULY 27, 2011 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ DEMO RCP AND RCP A3. rA RI 4E) BACK CP HOUSE CORRIDOR =TBNANT LEASE NO WOW THIS AREA - LINE -� (E) EXIT SIGN TO REMAIN n Ii TENANT LEASE LINE ; >1 ADJACENT TENANT SPACE - NO WORK T1416 AREA ADJACENT TENANT SPACE - NO WORK THIS AREA -\ e ° TENANT LEASE LINE • (E) MALL CONCOURSE —\ REFLECTED CEILING. PLAN 1/8" = 1'-0 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS r Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart • 24 — Add Reliable Model G Standard Response Semi -recessed 165° Pendents 1/2 x 1/2 • E — Existing pendent no change 24 — Total GROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 Mill CREEK, WASHINGTON . 98082-0113 PH. (425) 481-7669 Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformance with current City standards. Acceptance Is subject to errors and omissions Which do not authorize violations of adopted standards andlordinances. The, responsibility for the adequacy of: design rests totally with the designer. Additions, deletions c”. evisions to these drawings after this date will void Ms acceptance and will require a resubmittal of rcvisea drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. tDate:(7 -1 � -I Y• By: TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. ani exact addix.ss for shut- down hydown or restoration approval. Site Plan DAZE: Playlive 1230 Southcenter Mall Space 352 Tukwila, WA 98188 DRAWN: (c5" SCALE: • I./ $. JU TUK! l . C' PAID -72012 DILA FIRE