Loading...
HomeMy WebLinkAboutPP - 1249 SOUTHCENTER MALL - JC PENNEY - PERMITS AND PLANS1249 SOUTHCENTER MALL ASSOCIATED PERMITS 13-F-122 08-F-516 08-F-123 07-F-120 07-F-108 18-S-152 18-S-151 14-S-166 13-S-079 08-S-372 07-S-031 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT �► 444 Andover Park East Tukwila, WA 98188 ,`% li: PAID 206-575-4407` 1908 MAR 280 TT�LA a FIRE PROTECTION SYSTEMS PERMIT APPLICATIONU Date application accepted: Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address: 1249 SOUTHCENTER MALL Suite Number: Floor: B Tenant Name: JC PENNEY New Tenant? ❑ - Yes - No Property Owner's Name: JC PENNEY COMPANY, INC Mailing Address: 6501 LEGACY DR PLANO TX 75024 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: MATT GREENE Day Telephone: 253-377-2272 Company Name: Patriot Fire Protection, INC. Mailing Address: 2707 70th Ave E Tacoma WA 98424 E-mail Address: mattg@patriotfire.com City State Zip Fax Number: 253-922-615 Valuation of Project (contractor's bid price): $ 5,574 Scope of Work (please provide detailed information): Add and relocate sprinklers for T.I. walls t b2A/ /� PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR THORIZED AGENT: Signature: '' Date: 3/28/13 Print Name: MATT GREENE Day Telephone: 253-377-2272 Plan Pennit App.doc 5/14/10 TFD FP Form 8 4irr gminunn SITE LOCATION CITY OF TI IKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in oder to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: N2-1-11 6OO Cf' 1 / IO Suite Number: Floor. Tenant Name: IC , -C_n New Tenant? []- Yes Q - No Property Owner's Name: ,k1e_S f'v �'((�� Morn 1 Mailing Address: 2A—co b C Y7 met(/ l (/,T tf /Q G City State Tap CONTACT PERSON -if there are questions about the submittal. Name: Company Name: ` JY7D 9-1 re, 7B-0-tC r: Mailing YY1 11 1r-eP-K-1 E-mail Address:e iclill� Fax Number. Day Telephone: 1-12S.41F1-76)&9* City State Zip Contra:Ws City of Tukwila NICET III number. a760 • ©q t i7 Business License nwnber. SV G 06161 12 - Total number of new/relocated devices or sprinkler heads: 5 Valuation of Project (contractor's bid price): S ( CCO PD Scope of Work (please provide detailed information): V eA QCp�`-�-e t 2 ) a S o.) PERMIT APPLICATION NOTES Value of Co ruetion— In all uses, a value of cation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid udes 'the work on the site authorized by such permit is commenced within IRO daps alter its issonce,,nr ifahe work a thoriaed mi the site by such perms is suspended or abandoned fora period of IRO days after the time the work is commenced. d. Thar Fire Marshal is authorized to grant, in .. writing, one or more eta oftime, for periods not more than IRO days each. The extension shall be requested in writing and justifiable cause wed. I HEREBY CERTIFY THAT I HAVE REP 4ND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OV SER OR AUTH Signature: Print Name: Jef s -/c AGENT: 1n - Date: &/I Plan Penult App doc 822!14 `fFDFPFucin8' SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT" King Co. Assessor's Tax No.: Site Address: 12`-1 9 Sou \O M Q u-_ Tenant Name: C-'Q'CNv e•-? Suite Number. Floor: New Tenant? ❑ - Yes Z.- No Property Owner's Name: JGQ e t...YV'E1 GO inPP..N tsJ . Mailing Address: S3 ceAlctrt. (NUJ_ . TU tcw1 t.,p. WA 4 `g `3 �' Z3 `t0 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: QJ ST•" f 131:'ES Day Telephone: 244.6.-- 9LA 33/ Company Name: TOTS (.1.000 Nt`CGQ b .S e5.C'.s1R "'*/ ) Mailing Address: 12) w fs 1 PA Lir, , f TA) 011-A/vi AL. 3S -a i 1 City State Zip E-mail Address: fl LS OA C� 'T`1 C.) • t' ZM Fax Number: 5 - �i-12.— '-h`i Total number of new/relocated devices or sprinkler heads: 1 NSI 1 Ui_S LORE- 1'1 QLC>coNC Valuation of Project (contractor's bid price): $12 5`i o Scope of Work (please provide detailed information): M FM 'FA S`t1l't?,M •;4 W : Z'E V1 1-1/S ?A.40 Arc i 101.W N I S Are.v. szoia S N o$ ,4oRs-t—a-on.JS- PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R AUTHORIZED AGE : Signature: j /�% Print Name: e i L' &" ( Plan Permit App.doc Date: S Day Telephone: 1 ? 2- Lf -31- I a!i `r) 1t2/13 TFD FP Form S SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9 26247 - (SOSG Site Address: 1249 5owfa4-E141-E- L 131..YD. Suite Number: Floor: BASEMfrj r Tenant Name: , . C . r -P/ , Crim t; y New Tenant? El- Yes X- No W Property Owner's Name: E S'fi FI t:L-'Q ?go 1ER'(y MailingAddress:Pb 'B0> X309¢6 CA12-L59AP City CONTACT PERSON -if there are questions about the submittal. Name: 146t -ria / LLAILD Day Telephone: Zo (o 48Z - 643 G Company Name: RELi Art1 tjZ-E ?Ro )'CG'tlorl 1,4 G. Mailing Address: ISO Bo X 42-$ 1?RE5?od WA- 490 SO City State Zip E-mail Address: KEVIN CL/AercE F1 R.F . Co M Fax Number: 206 &8Z — (07 4¢ Total number of new/relocated devices or sprinkler heads: 2_< Valuation of Project (contractor's bid price): $ 7, 3 9S" . Scope of Work (please provide detailed information): AVD t 'R C L0 cATE 5pit-)wl KA-E1Z— i-1 EA'S' fo'R- Nevi 1, /A 5 CA ZO13 State Zip PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THF IE TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM A QED TO APPLY FOR THIS PERMIT. ' �� JUL 3 " 2014/ BUILDING OWNER OR AUTHORIZ) AGENT: TUK I Afi Signature: / Date: g —14 Print Name: /ZG4T7I 2 . M /1.4r4AP Day Telephone: Zo 48 2 — 6 6 3h. Plan Permit App.doc 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: JC Penney Co. 1249 Southcenter Mall. Permit No.: 08-S372 Date: July 10, 2008 Reviewer: Steve Kohler Fire Prevention Inspector/planreview (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All references are NFPA 13, 2007 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: J C Penney 1249 Southcenter Py Permit No.: 13-S-079 Date: April 1, 2013 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: JC Penney 1249 Southcenter Mall Permit No.: 18-S-151 Date: August 7, 2018 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: JC Penney 1249 Southcenter Mall Permit No.: 14-S-166 Date: August 7, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. . , FIRE DEPARTMENT FIRE ALARM PLAN REVIEW COMMENTS Project Name: JC Penney 1249 Southcenter Mall Permit No.: 08-F-123 Date: April 16, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Install fire alarm annunciator at the main south side entrance. • Install a weather-proof exterior bell/strobe next to the main south side entrance. • Install a fire department Knox keybox at the main south side entrance. • Provide remote L.E.D.'s for all above ceiling detectors. • Install a lockout device on all FA system dedicated circuit breakers. • If keypad is used, reset code to be 1-2-3-4-5. • When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or Fire Alarm Control". • Duct detectors to send a supervisory signal upon activation. • Obtain an additional fire alarm permit to install magnetic door hold -open devices and smoke detectors in shoe storage area. • Obtain a City of Tukwila electrical permit from the permit center. System Outline L Location JCPenney 0696-5 1200 Southcenter Mall Seattle, WA 98188 II. Codes A. 2002 NFPA 72 Chapters 1-10 as Applicable(Remote Station) B. 2002 NEC Articles 250, 725, 760 C. Local, City, State III. Control A. 1 MS9600 Fire Alarm Control B. 1 DACT-UD Dual Line Dialer C. 5 AL1002UL-ADA-J ADA Power Booster 10A@24VDC D. 1 AL4000LX Power Supply 4A @ 12 or 3A @ 24VDC IV. Fire Alarm Initiating Devices A. 1 BG-12LX Manual Pull Station Addressable B. 6 SD355 Smoke Detector Photo C. 0 H355R Heat Detector Rate of Rise D. 25 D350PL Duct Smoke Detector E. 4 Water Flow Connection Only, Provided by Others F. 9 Tamper Switch Connection Only, Provided by Others G. 2 Air Pressure Connection Only, Provided by Others V. Fire Alarm Indicating Devices A. 1 LCD -80F Annunciator LCD B. 46 PC2WH-177 Ceiling Horn strobe white 24VDC 177CD C. 5 PC2W-115 Ceiling Horn strobe white 24VDC 115CD D. 27 PC2W-75 Ceiling Horn strobe white 24VDC 75CD E. 46 PC2W-30 Ceiling Horn strobe white 24VDC 30CD F. 3 PC2W-15 Ceiling Horn strobe white 24VDC 15CD G. 2 P2W-110 Wall Horn strobe white 24VDC 110CD H 6 P2W-75 Wall Horn strobe white 24VDC 75CD I. 4 P2W-30 Wall Horn strobe white 24VDC 30CD J. 4 SCWH-177 Ceiling Strobe white 24VDC 177CD K. 8 SCW-115 Ceiling Strobe white 24VDC 115CD L. 18 SCW-75 Ceiling Strobe white 24VDC 75CD M. 44 SCW-30 Ceiling Strobe white 24VDC 30CD N. 9 SCW-15 Ceiling Strobe white 24VDC 15CD O. 2 SW -30 Wall Strobe white 24VDC 30CD P. 2 SW -15 Wall Strobe white 24VDC 15CD Q. 1 P2RK-110 Wall Horn strobe RED 24VDC Weather Proof VI. Zones All devices are addressable with there own address 1-159 detector addresses 1-159 module addresses SLC Loop is style 4 VII. Wiring All Circuits and Wiring Shall be "Power Limited" SLC Circuits Shall be 16/2 Shielded U.L. FPLP Cable Initiating Zones Shall be 18/2 or 18/4 U.L. FPLP Cable Indicating Circuits Shall be 14/2 U.L. FPLP Cable System Ground Shall be 14 THWN Green Conductor Under Ground and Outside Wire shall be 14 THWN in Approved Raceway VIII. Listings A. All Equipment Shall Be U.L. Listed and Compatible IX. Power Supply A. Primary - 110 VAC Dedicated 20 Amp Circuit B. Secondary - 25 Amp Hour Battery X. Alarm Supervision A. Human B. Remote Station Installing Branch/Contractor ADT Fire & Security ADT Tyco Fire & Security 14200 E Exposition Blvd. 11824 No Creek Parkway Aurora, CO 80012 Bothell, WA 98011 (303) 338-8200 (206) 624-3103 S994-183 UUFX Sequence of Operation agals wog aouaixe salengoy sagois pue sum' Jouaiu! saiengoy loJluo3 446!i SW3 46noigl sl46rl uo wnl saaplo-4 loop )IooiS ao4S asealaa aleo *noes asealaa nlainHV paie!oosse uMop sinus •Jaivao 6uuoi!uow pals!! In of algnal suwsuej .aivao Buuol!uow pais!I in of euB!s tios!niedns si!wsue�l ialuao Buuoi!uow pals!' in of Ieu6!s uuele si!wsueJI Jole!ounuue aiowa pue sued plum ie Ieu6!s elgnoil ale!ounuuy iole!ounuue eiowaj pue sued Io.aluoo le Ieu6!s Nosiiuedns alepunuuy Jole!ounuue alowai pue iaued Iaiuoo le pups wmele ale!ounuuy x x x x x x x x x x x x x x x x x x x x X x x x x x x x X x x x x x x (Sprinkler system Water flow Valve tamper Air Pressure High lAir Pressure Low inual pull station (Smoke detectors Iat panel I IDuct smoke detectors (Abnormal circuit or device 1 I 1 Standby Battery Calculations FireLite MS9600 JCPenney Seattle, WA 98188 .. .• ...• .• • .• .. • .• .• ..• • ...... • .. • .• Part Number : : :.: : :•:Oeie.iiptiiiii..• .: .: :•••••• • • .' : : : Quantity Per Device :: :00.1.3004:: Per Device : All Devices .......... .... .• • MS9600 Fire Alarm Control 1 0.120000 0.120000 0.170000 0.170000 DACT-UD Dual Line Dialer 1 0.100000 0.100000 0.132000 0.132000 LCD-80F Annunciator LCD 1 0.025000 0.025000 0.064000 0.064000 SD355 Smoke Detector Photo 6 0.000300 0.001800 0.000300 0.001800 H355R Heat Detector Rate of Rise 0 0.000300 0.000000 0.000300 0.000000 MDF-300 Monitor Module Dual Input 6 0.000750 0.004500 0.000750 0.004500 MMF-300 Monitor Module Single input 3 0.000400 0.001200 0.000510 0.001530 MMF-301 Montior Module Small 8 0.000375 0.003000 0.000375 0.003000 CRF-300 Control Module Relay 14 0.000270 0.003780 0.000510 0.007140 D350PL Duct Smoke Detector 25 0.000300 0.007500 0.000300 0.007500 RTS451KEY Remote test Switch 25 0.000000 0.000000 0.008000 0.200000 0.000000 0.000000 Total Aux current Max 3 Amps 0.267 Alarm 0.591 Signal Circuits ... . • .. .. .... .. ... . . . . . . . • :::Nato.:::•:: :QUitOrit::::• "" .. : : ' ••••• • Circuit. • :.: • • • • • . • .... Device .. : •:•:::::Otiiintity *. • . . . . • . . • • • • • • • • .. . ...• • • • • .... • • . •••••-•::P.r 0061:::M.1*IC:e.*: Circuit 1 AL1002UL-ADA-J 6.175 0.000 0.000 0.000 0.000 Total 1 Maximum 2.5 Amps 0.000 Circuit 2 AL1002UL-ADA-J 0.175 0.000 0.000 0.000 0.000 Total 2 Maximum 2.5 Amps 0.000 Circuit 3 P2RK-110 1 0.212 0.212 0.000 0.000 0.000 Total 3 Maximum 2.5 Amps 0.212 Circuit 4 0.000 0.000 0.000 0.000 Total 4 Maximum 2.5 Amps 0.000 Totals Maximum 6 Amps 0.212 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Max Wire Run Distance For AWG 14 3073 Actual Wire run Distance 100 Voltage Drop for 14 AWG wire 0.130 Voltage Drop = 2 " Wire Run Distance * 3.07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit / 100C Standby Hours 60 Standby Battery Draw 0.267 Standby Amp Hrs 16.007 Alarm Current 0.803 Alarm Current 5 Min 0.067 Battery Size Required with 5 Min. Alarm Time and 20% Reserv€ 19.288 Battery Size Supplied 25 A.H. JCPenney Standard Fire Alarm Zoning FireLite MS9600 Reporting Zone # Address Number Device Software Zone Software Zone Software Zone Software Zone Software Zone NAC #1 System sensor Sync 1 2 NAC #2 System sensor Sync 1 2 NAC #3 System sensor Sync 1 2 NAC #4 System sensor Sync 1 2 Relay #1 Alarm 1 2 Relay #2 Trouble 4 Relay #3 Supervisory 3 Loop #1 Module Addresses 160 1 Box Tampers Control 3 161 2 Box Tampers Battery Box 3 163 4 Water flow #1 1 164 5 Sprinkler Tamper Switch #1 3 165 6 Water flow #2 1 166 7 Sprinkler Tamper Switch #2 3 167 8 Water flow #3 1 168 9 Sprinkler Tamper Switch #3 3 169 10 Sprinkler Tamper Switch #4 3 170 11 Sprinkler Tamper Switch #5 3 171 12 Sprinkler Tamper Switch #6 3 172 13 Dry Water flow #1 1 173 14 Dry Sprinkler Tamper Switch #1 3 174 15 Air Pressure Switch High 3 175 16 Air Pressure Switch Low 1 176 17 Outside PIV #1 3 177 18 Outside PIV #2 3 178 19 Box Tampers Power Supply 3 179 20 Box Tampers Power Expander #1 3 180 21 Box Tampers Power Expander #2 3 181 22 Box Tampers Power Expander #° 3 182 23 Box Tampers Power Expander #4 3 183 24 Box Tampers Power Expander #E 3 228 69 Security Gate Release 1 2 229 70 Security Gate Release 1 2 230 71 Door Holders Release 1 2 233 74 EMS Light control 1 2 252 93 HVAC #1 Shutdown 41 253 94 HVAC #2 Shutdown 42 254 95 HVAC #3 Shutdown 43 255 96 HVAC #4 Shutdown 44 256 97 HVAC #5 Shutdown 45 257 98 HVAC #6 Shutdown 46 258 99 HVAC #7 Shutdown 47 259 100 HVAC #8 Shutdown 48 260 101 HVAC #9 Shutdown 49 261 102 HVAC #10 Shutdown 50 262 103 HVAC #11 Shutdown 51 263 104 HVAC #12 Shutdown 52 272 113 EOL Power Supervision MMF 61 273 114 EOL Power Supervision MMF 62 Detector Addresses 001 1 Smoke Detector at panel 2 002 2 Smoke Detector at Penthouse 2 003 3 Smoke Detector at Door Holders 2 004 4 Smoke Detector at Door Holders 2 005 5 Smoke Detector at Door Holders 2 006 6 Smoke Detector at Door Holders 2 021 21 AHU #1 Supply Duct Detector 3 41 022 22 AHU #1 Return Duct Detector 3 41 023 23 AHU #2 Supply Duct Detector 3 42 024 24 AHU #2 Return Duct Detector 3 42 025 25 AHU #3 Supply Duct Detector 3 43 026 26 AHU #3 Return Duct Detector 3 43 027 27 AHU #4 Supply Duct Detector 3 44 028 28 AHU #4 Return Duct Detector 3 44 029 29 AHU #5 Supply Duct Detector 3 45 JCPenney Standard Fire Alarm Zoning FireLite MS9600 Reporting Zone # Address Number Device Software Zone Software Zone Software Zone Software Zone Software Zone 030 30 AHU #5 Return Duct Detector 3 45 031 31 AHU #6 Supply Duct Detector 3 46 032 32 AHU #6 Return Duct Detector 3 46 033 33 AHU #7 Supply Duct Detector 3 47 034 34 AHU #7 Return Duct Detector 3 47 035 35 AHU #8 Supply Duct Detector 3 48 036 36 AHU #8 Return Duct Detector 3 48 037 37 AHU #9 Supply Duct Detector 3 49 038 38 AHU #9 Return Duct Detector 3 49 039 39 AHU #10 Supply Duct Detector 3 50 040 40 AHU #10 Return Duct Detector 3 50 041 41 AHU #11 Supply Duct Detector 3 51 042 42 AHU #11 Return Duct Detector 3 51 043 43 AHU #12 Supply Duct Detector 3 52 044 44 AHU #12 Return Duct Detector 3 52 Part Number AL4000LX Standby Battery Calculations Altronix AL4000LX JCPenney Seattle, WA 98188 Description: Quahti Power Supply 4A @ 12 or 3A @ 24VE 1 Staotltiy:;:;:;:::: Czurerif::::: ;hlartn ::::: £iirrent :: Per Deuice:;: Ail;Deviices: Per pevicE Ali Devices 0.060 0.060 0.060 0.060 :... Auxitiary,devic2s Maximum3 Amps A77 -716B Power Supervisory Relay Total Aux current 2 0.019 Max 3 Amps 0.038 0.000 0.098 Standby Hours Standby Battery Draw Standby Amp Hrs 24 0.098 2.352 Alarm Current Alarm Current 5 Mir 0.098 0.008 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 2.832 Battery Size Supplies 7 A.H. 0.019 0.038 0.000 Alarm 0.098 Standby Battery Calculations Altronix AL1OO2ULADA #1 JCPenney Seattle, WA 98188 iij :$tadbyiii:jCurent• .:.:::::,!07.6:::::.: : .:Current:;:.:.: ::tar:ui:CscnpUon;:;::ei:.0utity:.;.Per:Dvc:..Alt bevice§;i.PerDeve;..All'beices;: tNrtier: AL1002UL-ADA-J ADA Power Booster 10A924VDC 1 0.090 0.090 0.175 0.175 ....... .. .......• .• .... .• .. •.. Auxthary_devices Maximum 1 Amps" ':': , ; ::::........ i.. .. . 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits • .Alarrn' ' ' ' ' went. . ' :':':Circuit:':':':' ' ' ' ' ' ' ' : ' ' ' ' : ' ':: 4�evi*::::::.:::::.:::::::::::Cuantity:,:;:, ;:;:;:;:;:;:;:;:;:; ; ; ; ; ; ; ; ; ; ;• :;.Per.Device.;.; All:pevices. Circuit 1A PC2W-30 2 0.107 0.214 SCW-30 4 0.094 0.376 PC2W-75 1 0.176 0.176 PC2WH-177 2 0.290 0.580 ......................... ............................................;......;....-.-....• .• .• ..• .. 1,346 Circuit 1B PC2W-75 3 0.176 0.528 SCW-75 2 0.158 0.316 PC2W-30 2 0.107 0.214 0.000 1.058 Total 1 Maximum 2.5 Amps 2.404 Circuit 2A PC2WH-177 3 0.290 0.870 PC2W-115 1 0.218 0.218 SCW-75 1 0.158 0.158 0.000 ....... ........................................................................ ... 1.246 Circuit 2B PC2WH-177 3 0.290 0.870 PC2W-115 1 0.218 0.218 0.000 0.000 ......... .............. ....................................• ..• ..• ...•................. 1.088 Total 2 Maximum 2.5 Amps 2.334 Circuit 3A PC2WH-177 3 0.290 0.870 SCW-115 1 0.210 0.210 SCW-751 0.158 0.158 0.000 ...... ....... •'''''..... .. ............... 1.238 Circuit 3B SCW-30 3 0.094 0.282 PC2W-30 1 0.107 0.107 PC2W-75 2 0.176 0.352 PC2WH-177 1 0.290 0.290 .. ........... ................ 1.031 Total 3 Maximum 2.5 Amps 2.269 Circuit 4A PC2WH-177 2 0.290 0.580 SCW-115 1 0.210 0.210 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 Circuit 48 SCW-30 1 0.094 0.094 PC2W-30 1 0.107 0.107 PC2W-75 2 0.176 0.352 SCW-75 3 0.158 0.474 .......... .. .......... .. ........................................................ 1.027 Total 4 Maximum 2.5 Amps 2.087 Totals Maximum 10 Amps 9.094 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 484 523 526 615 Actual Wire run Distance 375 400 350 375 Voltage Drop for 14 AWG wire 3.099 3.060 2.660 2.441 Circuit 1B Circuit 28 Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 616 599 632 634 Actual Wire run Distance 525 300 550 550 Voltage Drop for 14 AWG wire 3.410 2.004 3.482 3.468 Voltage Drop = 2 * Wire Run Distance' 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts and a minimum voltage at the end of line of 16 Volts. Standby Hours 60 Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 9.269 Alarm Current 5 Min 0.769 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 7.403 Battery Size Supplied 18 AH. Standby Battery Calculations Altronix AL1002ULADA #2 JCPenney Seattle, WA 98188 ....... .::::::::::::::.:•:::•:•:::::::::::::*::::::::::::::::•:•:•.• • .•:-::*::•*::•::.:::.•:-:::::::-:•:•....:•:••:::::::::::::::::.:::$10051•:::::::::0*.01.:.::::::t.iPli: :::::.:'•Current • ::::::: : • art Number .: ::::::.::00knfrtiOri__: _:' ilOntiiir.::.'.::::: .0(3r :1:104:::. All: OeOcee: :: :F1 00010:::: .All :0*-4 ..:. AL1002UL-ADA- ADA Power Booster10424VDC 1 0.090 0.090 0.175 0.175 : ..• :•:AUZiiiarkdinitc4fAiliiiiidniAArriiii:". •.,.•.....,...,.•..,.. . . . . . . . . . . . 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits . ....... •:•:•:•••:•:•:•••:•:•:•:•. ., . , .. , .. , . , .. , .. . . , .. , .. Alorm.,. ..., Cunt.. .•.....- .....- .. .- ........ ,.. .........•. ..-.......::::: ..ii.c.tgi. .:::.... • • • . • . • . • . :.:.:.:::. 0..eN;juf.) :.:,:.: :.:,..:... .:::::06rit.iiy • • .:.: .. • • - :.. :.:,:,:•:.• .:,:.• ...PerPeY194.: :AlfPPS4P9•5. .w' Circuit 1A s. C :36 5 0.094 0.470 SCW-75 1 0.158 0.158 PC2W-30 1 0.107 0.107 PC2W-75 1 0.176 0.176 SCW-15 1 0.066 0.066 SCW-115 1 0.210 0.210 ............... ....... 1.187 Circuit 1B PC2WH-177 1 0.290 0.290 SCW-30 2 0.094 0.188 SCW-15 1 0.066 0.066 SCW-75 2 0.158 0.316 • ........ " " ' . • • • - - - • - • . . . . . . . . . . . . . . . . . . 0.860 . ........ . . . Total 1 Maximum 2.5 Am. ps 2.047 Circuit 2A SCW-30 4 0.094 0.376 PC2W-30 2 0.107 0.214 SCW-75 1 0.158 0.158 •:•:•:.:.' . • . • . :•:-:-:- .•:•:•:•:•:•.•.•:• .•:• •••:•:•:•:•:.:.:.:•:••• :.:.••:. • 0.748 Circuit 2B PC2W-30 1 0.107 0.107 SW-30 2 0.094 0.188 P2W-30 4 0.107 0.428 SW-15 2 0.066 0.132 • • ' • '•:•:•:-:-:-:•:•:•:-:-:-:•:•:•:•:•:•:•:•:•:•:•:-:•:•:.: 0.855 Total 2 Maximum 2.5 Ams 1.603 Circuit 3A PC2WH-177 3 0.290 0.870 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 0.000 - • ........ " " ' ' ' ' ' -•" • " ••• • " :•:•: . • " • • . • • • • • • ••• • • :. . . . . .... - . • . •:•:•: : :-:-:•:•:•:-:-:•: •.•:•'•••'• 1.140 .•.• . • . • .... • • • .... .•..•.•.•.• •.• Circuit 3B SCWH-177 2 0.281 0.562 PC2W-115 1 0.218 0.218 PC2WH-177 2 0.290 0.580 0.000 '-'• "•••• ..•.•.... •:•:•:•:•:•:•'• ..-: • • - ... 1360 Total 3 Maximum 2.5 Amps 2.500 Circuit 4A PC2WH-177 4 0.290 1.160 0.000 0.000 •: . : .... ' . :.:•: :.: :.:-:-:-:- 1.160 Circuit 4B PC2WH-177 2 0.290 0.580 PC2W-30 3 0.107 0.321 SCW-75 1 0.158 0.158 0.000 1.059 Total 4 Maximum 2.5 Amps 2.219 Totals Maximum 10 Amps 8.369 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 549 871 571 562 Actual Wire run Distance 425 525 425 350 Voltage Drop for 14 AWG wire 3.097 2.411 2.975 2.493 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 758 762 479 615 Actual Wire run Distance 400 500 350 525 Voltage Drop for 14 AWG wire 2.112 2.625 2.923 3.414 Voltage Drop = 2 * Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AWG ' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 8.544 Alarm Current 5 Min 0.709 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 7.331 Battery Size Supplied 18 A.H. • Standby Battery Calculations Altronix AL10O2ULADA #3 JCPenney Seattle, WA 98188 Standby:;:;::::: Current:::::::;:Alarm:.:;::.:.:: Current::::.:: .':'Partdumber%:'.':':':':':': l3escn ton':: %: %»:: %: %>:: >:' :'Cuantit' .':':':':':Per:Device:::':'All' bevices;:;: Per:00404 : Alibe*ices:: AL1002UL-ADAJ ADA Power Booster 10A�a 24VDC 1 0.090 0.090 0.175 0.175 ................ ........• -:Auxi6ary'dedicesMaximum'Amps......................:::. _ ......... . . 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm'. .Cur ant.'. ':Oircuit:':':':'':'''':'':'':'':''':'::: •:•Cevite::::'7::: ii: iii:Cuanbt ':'i: i»i»>.: i>i>ii»iii.PeriDevice`:;All:Devices. -2W-30 Circuit 1A PC 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 • 1.031 Circuit 1B PC2W-30 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 ;.. .................. .--. ..... 1.031 Total 1 Maximum 2.5 Ams 2.062 Circuit 2A PC2WH-177 2 0.290 0.580 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 SCWH-177 1 0.281 0.281 ........................................... ... ..• ..• .• .......•... ...... ................ 1.131 Circuit 28 PC2WH-177 4 0.290 1.160 0.000 0.000 0.000 1.160 Total 2 Maximum 2.5 Amps 2.291 Circuit 3A PC2W-75 2 0.176 0.352 PC2W-30 4 0.107 0.428 SCW-15 2 0.066 0.132 0.000 ...................... ................................................. 0.912 • • Circuit 3B PC2W-75 4 0.176 0.704 PC2W-30 5 0.107 0.535 0.000 0.000 .................. .................................................. 1.239 • Total 3 Maximum 2.5 Amps 2.151 Circuit 4A P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 0.000 0.000 .......•. .......................... ..... ....... 0.740 Circuit 4B P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 0.000 0.000 Total 4 Maximum 2.5 Amps 1.480 Totals Maximum 10 Amps 7.984 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 632 576 714 880 Actual Wre run Distance 550 475 450 550 Voltage Drop for 14 AWG wire 3.482 3.299 2.520 2.499 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 632 562 526 880 Actual Wire run Distance 575 350 450 550 Voltage Drop for 14 AWG wire 3.640 2.493 3.423 2.499 Voltage Drop = 2 ' Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 8.159 Alarm Current 5 Min 0.677 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 7.293 Battery Size Supplied 18 A.H. Standby Battery Calculations Altronix AL1002ULADA #4 JCPenney . . . . . . . . . . . . . . . . . . . . Seattle, WA 98188 . . . . . . . . . . . . ............ . . . . . . . . . . . . . . . . . . . . ...... . . . . . . . . . . . ' ••••••••••••••••••• ••••"•••••••••• • • •••••" •-• • •••••••• • •• . . . . . . . . . . . . ...... .. . . . . . . .•.• . ..... .. ..... ...... . . ..........,................Stanitby ..1unent.....Alarm.......Current... :.:.:::.:.:.•• Ir.**44:1`10050c.:•:•: •::.:::0!40006.. • •:...:•:..•••:......• : :0,4614.:- -:.:::.1.10r-00vic*':::4:061cee:.:.1.40rbriVige *•::All'OeVic*: A11002UL-ADA-J ADA Power Booster 1.0424VDC 1 0.090 0.090 0.175 0.175 ::.•.•:AUxiliarydevices Maxirrium• AmOs•••••••••• :••• .. •• ..... • .. : : : : : : ' 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits ...... ...... - ..................,.,......... .........:.:...:.:.:-:-:-:.:.:-:.:-:.:.:.:-:.:.•.:Nprip:-: ..:....•.(Vrgint.: • .:: 0ricqit.-.:.::: .:....••••••••:•••••:::::.0esiluo:.:.•.:.:.:........ Q.ufriti4i::::::::::::..::::::::::.• ::::::.::•:.:::.000010::::Alf00vi*: Circuit 1A SCW14 -177 1 0.281 0.281 SCW-75 2 0.158 0.316 SCW-30 3 0.094 0.282 PC2W-115 1 0.218 0.218 . . . .• ... •••.. .• • • ....•.•...• •.• .•• " .... • ' • • " " ••••••••• 1.097 Circuit 1B PC2WH-177 4 0.290 1.160 0.000 0.000 0.000 - . .... • ...... •.•.-.- . - . - ... . . • ••• :•:•:•:• •• : .. • .. • . ••••••:•:•:. • :•:•••:•• • • • • • • • • • • • ' • • ••••:•••••••••:•: :.: :•:•:•:•:•: • 1.160 Total 1 Maximum 2.5 Amps 2.257 Circuit 2A PC2WH-177 1 0.290 0.290 PC2W-30 2 0.107 0.214 SCW-115 1 0.210 0.210 PC2W-115 1 0.218 0.218 -:•:•:•:-:•:•:- 0.932 Circuit 2B PC2WH-177 3 0.290 0.870 SCW-115 1 0.210 0.210 PC2W-30 1 0.107 0.107 0.000 .•.•.•.•.•.•.•.•.....•. .• 1.187 :•:•:•:•:•:•:•:•:• •:•:•:•:•:•:•: . . ' " ' " ' • • • ' • Total 2 Maximum 2.5 Amps 2.119 Circuit 3A PC2WH-177 1 0.290 0.290 SCW-115 1 0.210 0.210 PC2W-75 2 0.176 0.352 .•.-.- ....• ... . . . . ••• •••• . . . .......... .•......... ........ . . . . ... . . . .. ...... ... .•7 ........... . ............... . . . ...... ........ ...... .........-....... . • .... • ... • . • ........•...• .. • . • .. - • 0.852 Circuit 3B PC2WH-177 3 0.290 0.870 PC2W-75 1 0.176 0.176 0.000 :-:•:- ... • ..... . .. 1.046 Total 3 Maximum 2.5 Amps 1.898 Circuit 4A PC2WH-177 1 0 290 0.290 SCW-115 1 0.210 0.210 PC2W-75 1 0.176 0.176 SCW-30 3 0.094 0.282 .•:, ...... • . • . •:•••:•••:•:•:•:•:•:•:•:•'••• •.-.• . • . :. . :•:•:• .. • . • .. •: . •:•:-.-.•:•:•. :. 0.958 Circuit 48 SCW-115 1 0.210 0.210 SCW-15 2 0.066 0.132 SCW-30 1 0.094 0.094 SCW-75 1 0.158 0.158 PC2W-75 1 0.176 0.176 PC2WH-177 1 0.290 0.290 .... • 1.060 Total 4 Maximum 2.5 Amps 2,018 Totals Maximum 10 Amps 8.292 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 594 699 765 680 Actual Wire run Distance 550 450 425 550 Voltage Drop for 14 AWG wire 3.705 2.575 2.223 3.235 Circuit 1B Circuit 2B Circuit 38 Circuit 4B Max Wre Run Distance For AWG 14 562 549 623 615 Actual Wre run Distance 425 425 425 500 Voltage Drop for 14 AWG wire 3.027 3.097 2.730 3.254 Voltage Drop = 2 *Wire Run Distance* 3.07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts, Calculations assume that all devices are at the end of the line. Standby Battery Draw 0.090 Standby Amp Hrs 5.400 Alarm Current 8.467 Alarm Current 5 Min 0.703 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 7.323 !Battery Size Supplied 18 A.H. Standby Battery Calculations Altronix AL1002ULADA #5 JCPenney Seattle, WA 98188 .. . . . . . .... . . . . . ... .StOd!Si::::::::u.ir.e4:::::.:.0.ktami:.:.:..: :.09rrpot.:•:... .:.:.: :::....1?O'N061601.: ...:.:,:,..:.:00krip..06:. :.:,...::.::::.::,:,:.:, ..::,:$14*Itk...::::::::140:0014::::#1:0010i::::1.40r:0410.::::NI:beyi64:: . AL1002UL-ADA-./ ADA Power Booster 10A24VDC 1 0.090 0.090 0.175 0.175 • :• :• :• :• . Auxiiiarj,itiaviCei firlqiirrium•3 Xmlis • :• .• • . :• :• :• .• :• 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits .......... ..... , , , ' . ''' -:.....:.....• •.:.:.:..:.:.. ........:, .:.:.:.:.:...:.:::::.: :::, ' ::::.........: •:...Nalift):.....: ..' • OUrqftft :. ::.....::.•011icilit•'•:: ' ::::':.:.:.....'•••• t3evice .:: .:::.::::::::::00r.itiiy:::.:::::::.:,:::::.:.:.: ':':::: :::: :::Oert*Icq:•:.AllbeY:i*: Circuit 1A PC-2W-30 5 0.107 0.535 SCW-30 3 0.094 0.282 SCW-75 1 0.158 0.158 0.000 ._. -•••:•• •.•• • • . • .• : .•. • . . . 0.975 Circuit 1B PC2W-30 1 0.107 0.107 PC2W-15 1 0.079 0.079 PC2W-75 1 0.176 0.176 SCW-30 4 0.094 0.376 SCW-15 2 0.066 0.132 . . . . . . . . . . . . . . . . :.: :-•• • • :.:. : • • • • • • • • • • - • . . . . . . . . . 0.870 Total 1 Maximum 2.5 Amps 1.845 Circuit 2A PC2W-30 1 0.107 0.107 PC2W-75 1 0.176 0.176 PC2W-15 2 0.079 0.158 SCW-15 1 0.066 0.066 SCW-75 2 0.158 0.316 :• ' • ' • ''' • ' • ' • .• '• :• :• :• : • • '• :• :• :• :• :• : :-:•:•:•:•:•:•:•:•:•:•:-.•:• • : • : • : • ' • : • : • : • ' • ' • :::: • : • : • : • : • : .: 0.823 Circuit 2B PC2W-75 2 0.176 0.352 SCW-30 2 0.094 0.188 0.000 0.000 :• :• :• :• :• .• :• :• • • " • • ' ' :•:•:•:•:.: :•:•:•: ' • • :• :• :• :.:• :• :• :• :• :•.• '• :..... :. :. ' • ' • • • :• .• :. : .: ..........: : 0.540 Total 2 Maximum 2.5 Amps 1.363 Circuit 3A 0.000 0.000 0.000 0.000 '''''' ' • :-:•'.'•'•"•:•:•.•: • " • • :• '•:.• ..:•: :.:.: ' • '' • ' . ' •" • 0.000 Circuit 3B 0.000 0.000 0.000 0.000 Total 3 Maximum 2.5 Amps 0.000 Circuit 4A 0.000 0.000 0.000 0.000 :•:•:•:. :• :• :• :•.• • ..• 0.000 Circuit 4B 0.000 0.000 0.000 • :• .• ..'• '• :• .:•.• ' • '' • '' • : .:•:•'•:•:•:•.•.•.•:•:•:•:.:•:•:•:.:•:-:•:•:•'•:•:•:•:•:•:•.•:•:-..:•:•'•'-:•.-:•. :•:•:.:•:•:•:•.•:•.•:.:.:•:•:.: . . .• .• : • : . ::::: - . .. 0.000 Total 4 Maximum 2.5 Amps 0.000 Totals Maximum 10 Amps 3.208 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 668 792 . Actual Wire run Distance 450 375 Voltage Drop for 14 AWG wire 2.694 1.895 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wre Run Distance For AWG 14 749 1206 Actual Wre run Distance 400 400 Voltage Drop for 14 AWG wire 2.137 1.326 Voltage Drop = 2 * Wire Run Distance ' 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 3.383 Alarm Current 5 Min 0.281 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 6.817 !Battery Size Supplied 18 A.H. I System Outline Location JCPenney 0696-5 1200 Southcenter Mall Seattle, WA 98188 II. Codes A. 2002 NFPA 72 Chapters 1-10 as Applicable(Remote Station) B. 2002 NEC Articles 250, 725, 760 C. Local, City, State III. Control A. 1 MS9600 Fire Alarm Control B. 1 DACT-UD Dual Line Dialer C. 5 AL1002UL-ADA-J ADA Power Booster 10A@24VDC D. 1 AL4000LX Power Supply 4A @ 12 or 3A @ 24VDC IV. Fire Alarm Initiating Devices A. 6 SD355 Smoke Detector Photo B. 25 D350PL Duct Smoke Detector C. 4 Water Flow Connection Only, Provided by Others D. 9 Tamper Switch Connection Only, Provided by Others E. 2 Air Pressure Connection Only, Provided by Others V. Fire Alarm Indicating Devices A. 1 LCD -80F Annunciator LCD B. 46 PC2WH-177 Ceiling Horn strobe white 24VDC 177CD C. 5 PC2W-115 Ceiling Horn strobe white 24VDC 115CD D. 27 PC2W-75 Ceiling Horn strobe white 24VDC 75CD E. 46 PC2W-30 Ceiling Horn strobe white 24VDC 30CD F. 3 PC2W-15 Ceiling Horn strobe white 24VDC 15CD G. 2 P2W-110 Wall Horn strobe white 24VDC 110CD H 6 P2W-75 Wall Horn strobe white 24VDC 75CD I. 4 P2W-30 Wall Horn strobe white 24VDC 30CD J. 4 SCWH-177 Ceiling Strobe white 24VDC 177CD K. 8 SCW-115 Ceiling Strobe white 24VDC 115CD L. 18 SCW-75 Ceiling Strobe white 24VDC 75CD M. 44 SCW-30 Ceiling Strobe white 24VDC 30CD N. 9 SCW-15 Ceiling Strobe white 24VDC 15CD O. 2 SW -30 Wall Strobe white 24VDC 30CD P. 2 SW -15 Wall Strobe white 24VDC 15CD Q. 1 P2RK-110 Wall Horn strobe RED 24VDC Weather Proof VI. Zones All devices are addressable with there own address 1-159 detector addresses 1-159 module addresses SLC Loop is style 4 VII. Wiring All Circuits and Wiring Shall be "Power Limited" SLC Circuits Shall be 16/2 Shielded U.L. FPLP Cable Initiating Zones Shall be 18/2 or 18/4 U.L. FPLP Cable Indicating Circuits Shall be 14/2 U.L. FPLP Cable System Ground Shall be 14 THWN Green Conductor Under Ground and Outside Wire shall be 14 THWN in Approved Raceway VIII. Listings A. All Equipment Shall Be U.L. Listed and Compatible IX. Power Supply A. Primary - 110 VAC Dedicated 20 Amp Circuit B. Secondary - 25 Amp Hour Battery X. Alarm Supervision A. Human B. Remote Station Installing Branch/Contractor ADT Fire & Security ADT Tyco Fire & Security 14200 E Exposition Blvd. 11824 No Creek Parkway Aurora, CO 80012 Bothell, WA 98011 (303) 338-8200 (206) 624-3103 S994-183 UUFX Sequence of Operation egoiis UJ011JOUaIX9 SalenRov sagojis pue swot' Joualu! salengoy IoJiuo3 jg6il SW3 g6nojgi sjg611 uo uJnl sJaPIoH iooa Noois goys aseelaa °leg *noes asealaa nla/nHV paleloosse uMop sings .Jaluao 6uuolluow pals!' In of algnoil sllwsueJl 1011190 6uuolluow pals!! in 01 eu6ls fuosyuadns sllwsueJj JalueO 6uuolluow pals!! in of Ieu6ls wme'e sllwsueJj Jole!Ounuue alowaJ pue sued loniuoo le Ieu6ls a'gnoji alepunuuy Jole!ounuue alma.' pue sued loJiuoo le leu6ls JGos!AJadnS ale!ounuuy Jolepunuue alowaJ pue 'sued loJluoo le leu6!s LJele alelounuuy x x x x x x x x x x x x x x x x x x x x X x x x x x x x X x x x x x x Sprinkler system Water flow Valve tamper Air Pressure High Air Pressure Low Manual pull station _ Smoke detectors at .anel Duct smoke detectors 'Abnormal circuit or device Standby Battery Calculations FireLite MS9600 JCPenney Seattle, WA 98188 Standby Current • Alarm.. .....Curreht ..,- Part,Number Description Quantity. Per Device Alt Devices - Per Device. All Devices MS9600 Fire Alarm Control 1 0.120000 0.120000 0.170000 0.170000 DACT-UD Dual Line Dialer 1 0.100000 0.100000 0.132000 0.132000 LCD-80F Annunciator LCD 1 0.025000 0.025000 0.064000 0.064000 SD355 Smoke Detector Photo 6 0.000300 0.001800 0.000300 0.001800 MDF-300 Monitor Module Dual Input 6 0.000750 0.004500 0.000750 0.004500 MMF-300 Monitor Module Single input 5 0.000400 0.002000 0.000510 0.002550 MMF-301 Montior Module Small 8 0.000375 0.003000 0.000375 0.003000 CRF-300 Control Module Relay 16 0.000270 0.004320 0.000510 0.008160 D350PL Duct Smoke Detector 25 0.000300 0.007500 0.000300 0.007500 RTS451 KEY Remote test Switch 25 0.000000 0.000000 0.008000 0.200000 0.000000 0.000000 0.000000 0.000000 Total Aux current Max 3 Amps 0.268 Alarm 0.594 Signal Circuits Alarm :- current Circuit' Device Quantity . Per Device :Alt Devices Circuit 1 AL1002UL-ADA-J 0.175 0.000 0.000 0.000 0.000 Total 1 Maximum 2.5 Amps 0.000 Circuit 2 AL1002UL-ADA-J 0.175 0.000 0.000 0.000 0.000 Total 2 Maximum 2.5 Amps 0.000 Circuit 3 P2RK-110 1 0.212 0.212 0.000 0.000 0.000 Total 3 Maximum 2.5 Amps 0.212 Circuit 4 0.000 0.000 0.000 0.000 Total 4 Maximum 2.5 Amps 0.000 Totals Maximum 6 Amps 0.212 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Max Wire Run Distance For AWG 14 3073 Actual Wire run Distance 100 Voltage Drop for 14 AWG wire 0.130 Voltage Drop = 2 * Wire Run Distance * 3.07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit / 100C Standby Hours 60 Standby Battery Draw 0.268 Standby Amp Hrs 16.087 Alarm Current 0 806 Alarm Current 5 Min 0.067 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 19.385 Battery Size Supplied 25 A.H. JCPenney Standard Fire Alarm Zoning FireLite MS9600 Reporting Zone # Address Number Device Software Zone Software Zone Software Zone Software Zone Software Zone NAC #1 System sensor Sync 1 2 NAC #2 System sensor Sync 1 2 NAC #3 System sensor Sync 1 2 NAC #4 System sensor Sync 1 2 Relay #1 Alarm 1 2 Relay #2 Trouble 4 Relay #3 Supervisory 3 Loop #1 Module Addresses 160 1 Box Tampers Control 3 161 2 Box Tampers Battery Box 3 163 4 Water flow #1 1 164 5 Sprinkler Tamper Switch #1 3 165 6 Water flow #2 1 166 7 Sprinkler Tamper Switch #2 3 167 8 Water flow #3 1 168 9 Sprinkler Tamper Switch #3 3 169 10 Sprinkler Tamper Switch #4 3 170 11 Sprinkler Tamper Switch #5 3 171 12 Sprinkler Tamper Switch #E 3 172 13 Dry Water flow #1 1 173 14 Dry Sprinkler Tamper Switch #1 3 174 15 Air Pressure Switch Higt 3 175 16 Air Pressure Switch Low 1 176 17 Outside PIV #1 3 177 18 Outside PIV #2 3 178 19 Box Tampers Power Supply 3 179 20 Box Tampers Power Expander #1 3 180 21 Box Tampers Power Expander #2 3 181 22 Box Tampers Power Expander #2 3 182 23 Box Tampers Power Expander #4 3 183 24 Box Tampers Power Expander #5 3 228 69 Security Gate Release 1 2 229 70 Security Gate Release 1 2 230 71 Door Holders Release 1 2 233 74 EMS Light control 1 2 252 93 HVAC #1 Shutdown 41 253 94 HVAC #2 Shutdown 42 254 95 HVAC #3 Shutdown 43 255 96 HVAC #4 Shutdown 44 256 97 HVAC #5 Shutdown 45 257 98 HVAC #6 Shutdown 46 258 99 HVAC #7 Shutdown 47 259 100 HVAC #8 Shutdown 48 260 101 HVAC #9 Shutdown 49 261 102 HVAC #10 Shutdown 50 262 103 HVAC #11 Shutdown 51 263 104 HVAC #12 Shutdown 52 272 113 EOL Power Supervision MMF 61 273 114 EOL Power Supervision MMF 62 Detector Addresses 001 1 Smoke Detector at panel 2 002 2 Smoke Detector at Penthouse 2 003 3 Smoke Detector at Door Holders 2 004 4 Smoke Detector at Door Holders 2 005 5 Smoke Detector at Door Holders 2 006 6 Smoke Detector at Door Holders 2 021 21 AHU #1 Supply Duct Detector 3 41 022 22 AHU #1 Return Duct Detector 3 41 023 23 AHU #2 Supply Duct Detector 3 42 024 24 AHU #2 Return Duct Detector 3 42 025 25 AHU #3 Supply Duct Detector 3 43 026 26 AHU #3 Return Duct Detector 3 43 027 27 AHU #4 Supply Duct Detector 3 44 028 28 AHU #4 Return Duct Detector 3 44 029 29 AHU #5 Supply Duct Detector 3 45 JCPenney Standard Fire Alarm Zoning FireLite MS9600 Reporting Zone # Address Number Device Software Zone Software Zone Software Zbne Software Zone Software Zone 030 30 AHU #5 Return Duct Detector 3 45 031 31 AHU #6 Supply Duct Detector 3 46 032 32 AHU #6 Return Duct Detector 3 46 033 33 AHU #7 Supply Duct Detector 3 47 034 34 AHU #7 Return Duct Detector 3 47 035 35 AHU #8 Supply Duct Detector 3 48 036 36 AHU #8 Return Duct Detector 3 48 037 37 AHU #9 Supply Duct Detector 3 49 038 38 AHU #9 Return Duct Detector 3 49 039 39 AHU #10 Supply Duct Detector 3 50 040 40 AHU #10 Return Duct Detector 3 50 041 41 AHU #11 Supply Duct Detector 3 51 042 42 AHU #11 Return Duct Detector 3 51 043 43 AHU #12 Supply Duct Detector 3 52 044 44 AHU #12 Return Duct Detector 3 52 Part Number. AL4000LX Standby Battery Calculations Altronix AL4000LX JCPenney Seattle, WA 98188 Standby :Current Alarm :Current Description .:Quantity Per Device RIIDevices PerDevic All•Devices Power Supply 4A @ 12 or 3A @ 24VE 1 0.060 0.060 0.060 0.060 Auxiliary devices Maximum 3 Amps.. A77-7166 Power Supervisory Relay Total Aux current 2 0.019 0.038 0.000 Max 3 Amps 0.098 Standby Hours 24 Standby Battery Draw 0.098 Standby Amp Hrs 2.352 Alarm Current 0.098 Alarm Current 5 Mir 0.008 Battery Size Required with 5 Min. Alarm Time and 20% ReservE 2.832 (Battery Size Supplies 7 A.H. I 0.019 0.038 0.000 Alarm 0.098 Standby Battery Calculations Altronix AL1002ULADA #1 JCPenney Seattle, WA 98188 - - .... .... .. ...Standby_._.�' ...urrent.: ...Alarm':.:.:.'.:.Current ,.• Part Number ' .Description '• • • • Quantity . Per All Devices Per Device' M Devices • • . AL1002UL-AOA-J ADA Power Booster 10Al 24VDC 1 0.090 0.090 0 175 0 175 'Auxdrary_devices Maximum 3 Amps .. ... .• ..' .. . 0 000 0.000 0 000 0 000 Total Aux current Max 3 Amps 0 090 Alarm 0 175 Signal Circuits ' . Current ' _Alarm Circuit-' - - - - - 'Device , - -Quantity .- - - - - -Per Device All Devices Circuit 1A PC2W-30 2 0 107 0 214 SCW-30 4 0.094 0 376 PC2W-75 1 0.176 0.176 PC2WH-177 2 0.290 0 580 - - - . ... .. .. . .. 1 346 Circuit 1B PC2W-75 3 0.176 0528 SCW-75 2 0.158 0.316 PC2W-30 2 0.107 0.214 0 000 1 058 Total 1 Maximum 2.5 Amps 2.404 Circuit 2A PC2WH-177 3 0.290 0.870 PC2W-115 1 0.218 0.218 SCW-75 1 0158 0.158 0.000 1246 Circuit 20 PC2WH-177 3 0.290 0 870 PC2W-115 1 0.218 0 218 0 000 0 000 .. :.. - .. 1088 Total 2 Maximum 2.5 Amps 2.334 Circuit 3A PC2WH-177 3 0.290 0870 SCW-115 1 0.210 0.210 SCW-751 0158 0.158 0.000 .. .. ... .. .. .. 1.238 Circuit 3B SCW-30 3 0.094 0.282 PC2W-30 1 0.107 0.107 PC2W-75 2 0.176 0.352 PC2WH-177 1 0.290 0.290 -. ... ... ,, 1.031 Total 3 Maximum 2 5 Amps 2 269 Circuit 4A PC2WH-177 2 0 290 0.580 SCW-115 1 0 210 0.210 PC2W-75 1 0176 0176 SCW-30 1 0 094 0 094 . :... 1.060 Circuit 48 SCW-30 1 0 094 0.094 PC2W-30 1 0.107 0.107 PC2W-75 2 0 176 0.352 SCW-75 3 0.158 0.474 .. :. ... 1.027 Total 4 Maximum 2.5 Amps 2 087 Totals Maximum 10 Amps 9.094 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wre Run Distance ForAWG 14 484 523 526 615 Actual Wire run Distance 375 400 350 375 Voltage Drop for 14 AWG wire 3 099 3.060 2 660 2.441 Circuit 18 Circuit 2B Circuit 3B Circuit 48 Max Wire Run Distance ForAWG 14 616 599 632 634 Actual Wire run Distance 525 300 550 550 Voltage Drop for 14 AWG wire 3.410 2.004 3 482 3 468 Voltage Drop = 2' Wire Run Distance • 3 07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 9.269 Alarm Current 5 Min 0.769 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 7.403 I 'Battery Size Supplied 18 A H. Standby Battery Calculations Altronix AL1002ULADA #2 JCPenney Seattle, WA 98188 - . Standby. - Current... -.Alarm :,., . Purism: :.: • Part Number • ..Description '_ :, •Quantity. : Per Device All Devices. Per Device:: All-bevices AL1002UL-ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0 175 0.175 .- ... ... . Auxiliary devices Manmum'3Amps' - 0.000 0.000 0 000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0 175 Signal Circuits Alarm ' .' Current.' :Circuit: . - -'. -- - - Device ., .. ... .Quantity : :::.: :i ;.: .... - :':Per Device ;At.Dewpes Circuit 1A SCW-30 5 0.094 0.470 SCW-75 1 0.158 0.158 PC2W-30 1 0107 0.107 PC2W-75 1 0.176 0.176 SCW-15 1 0.066 0.066 SCW-115 1 0 210 0.210 1.187 Circuit 1B PC2WH-177 1 0 290 0.290 SCW-30 2 0094 0188 SCW-15 1 0.066 0.066 SCW-75 2 0.158 0.316 0.860 Total 1 Maximum 2 5 Amps 2 047 Circuit 2A SCW-30 4 0.094 0 376 PC2W-30 2 0 107 0.214 SCW-75 1 0.158 0158 . .. .., .. .... 0748 Circuit 2B PC2W-30 1 0.107 0.107 SW -30 2 0.094 0.188 P2W-30 4 0107 0.428 SW -15 2 0.066 0.132 ... .. ... ... .- ..,. 0855 Total 2 Maximum 2.5 Amps 1.603 Circuit 3A PC2WH-177 3 0.290 0.870 PC2W-75 1 0176 0.176 SCW-30 1 0.094 0.094 0.000 1.140 Circuit 3B SCWH-177 2 0.281 0.562 PC2W-115 1 0.218 0.218 PC2WH-177 2 0.290 0.580 0 000 . . . .. 1.360 Total 3 Maximum 2.5 Amps 2.500 Circuit 4A PC2WH-177 4 0.290 1160 0 000 0.000 ... .. .. .. ..'' .:'. 1.160 Circuit 48 PC2WH-177 2 0.290 0.580 PC2W-30 3 0.107 0 321 SCW-75 1 0.158 0.158 0 000 .. .. ... .. ' ' 1.059 Total 4 Maximum 2 5 Amps 2.219 Totals Maximum 10 Amps 8 369 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 549 871 571 562 Actual Wire run Distance 425 525 425 350 Voltage Drop for 14 AWG wire 3.097 2 411 2 975 2 493 Circuit 1 B Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 758 762 479 615 Actual Wire run Distance 400 500 350 525 Voltage Drop for 14 AWG wire 2.112 2 625 2 923 3 414 Voltage Drop = 2' Wre Run Distance' 3 07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20 4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 8.544 Alarm Current 5 Min 0.709 Battery Size Required with 5 Min Alarm Time and 20% Reserve 7331 I (Battery Size Supplied 18 A H. Standby Battery Calculations Altronix AL1OO2ULADA #3 JCPenney Seattle, WA 98188 _ Standby , Current , , Alarm ' Current Part Number Description _ ' ... ,,-Quantity - Per Device. All_bewces• Per Device: :iMOevices• AL1002UL-ADA-J ADA Power Booster 10A924VDC 1 0.090 0.090 0.175 0 175 ' Auxiliary'devicesMaximum 3Amps . -' 0.000 0.000 0.000 0 000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits . ,Alarra Current ' Circuit ' • Devise . .Quanttty .Per Device Alf Devices Circuit 1A PC2W-30 7 0.107 0.749 SCW-30 3 0 094 0.282 0.000 0 000 .. ..,. ... .,, .. 1.031 Circuit 1B PC2W-30 7 0.107 0.749 SCW-30 3 0 094 0 282 0 000 0 000 1.031 Total 1 Maximum 2.5 Amps 2 062 Circuit 2A PC2WH-177 2 0290 0 580 PC2W-75 1 0176 0.176 SCW-30 1 0 094 0.094 SCWH-177 1 0 281 0.281 .. .. ..... ... .... ..'.. 1131 Circuit 2B PC2WH-177 4 0.290 1 160 0.000 0 000 0.000 1.160 Total 2 Maximum 2.5 Amps 2.291 Circuit 3A PC2W-75 2 0 176 0.352 PC2W-30 4 0107 0428 SCW-15 2 0066 0132 0.000 0.912 Circuit 36 PC2W-75 4 0.176 0.704 PC2W-30 5 0.107 0.535 0.000 0.000 1.239 Total 3 Maximum 2.5 Amps 2.151 Circuit 4A P2W-75 3 0.176 0.528 P2W-110 1 0.212 0212 0.000 0.000 ., ... 0.740 Circuit 4B P2W-75 3 0.176 0.528 P2W-110 1 0212 0212 0 000 0.000 0.740 Total 4 Maximum 2 5 Amps 1.480 Totals Maximum 10 Amps 7 984 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 632 576 714 880 Actual Wire run Distance 550 475 450 550 Voltage Drop for 14 AWG wire 3.482 3 299 2 520 2.499 Circuit 16 Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 632 562 526 880 Actual Wire run Distance 575 350 450 550 Voltage Drop for 14 AWG wire 3.640 2.493 3 423 2.499 Voltage Drop = 2 • Wire Run Distance' 3.07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 8.159 Alarm Current 5 Min 0 677 Battery Size Required with 5 Min Alarm Time and 20% Reserve 7 293 Battery Size Supplied 18 A.H. Standby Battery Calculations Altronix AL1OO2ULADA #4 JCPenney Seattle, WA 98188 Standby.: Currentiii.Alarm:. :<OlijtrBnt i..: Part Number :: ` :.' Description : , , , ..' Cuantity.....•.:.Per Device All bevices is Per Device. All bevices ' AL1002UL-ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Auxlbary_devicesMaximum'3Amps - - 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits ... ... ... .. Alarm, �::. Current , _ ' Circuit Device : ' Quantity • '.Per.Device All Devices Circuit 1A SCWH-177 1 0.281 0.281 SCW-75 2 0.158 0 316 SCW-30 3 0 094 0.282 PC2W-115 1 0.218 0.218 ., .. .....,. 1097 Circuit 1B PC2WH-177 4 0.290 1 160 0.000 0 000 0.000 .. - ... .. ..ii.. .160 Total 1 Maximum 2.5 Amps 2.257 Circuit 2A PC2WH-177 1 0.290 0 290 PC2W-30 2 0.107 0.214 SCW-115 1 0 210 0.210 PC2W-115 1 0.218 0.218 ., .. ., - ., -.. .. .. 0.932 Circuit 2B PC2WH-177 3 0.290 0 870 SCW-115 1 0.210 0.210 PC2W-30 1 0.107 0.107 0.000 1.187 Total 2 Maximum 2.5 Amps 2.119 Circuit 3A PC2WH-177 1 0 290 0.290 SCW-115 1 0.210 0.210 PC2W-75 2 0176 0.352 .., ., .. ......: 0.852 Circuit 3B PC2WH-177 3 0.290 0.870 PC2W-75 1 0.176 0.176 0 000 1.046 Total 3 Maximum 2.5 Amps 1 898 Circuit 4A PC2WH-177 1 0.290 0 290 SCW-115 1 0.210 0210 PC2W-75 1 0.176 0.176 SCW-30 3 0 094 0 282 ., .,.. .. 0.958 Circuit 46 SCW-115 1 0.210 0.210 SCW-15 2 0.066 0.132 SCW-301 0.094 0 094 SCW-75 1 0.158 0.158 PC2W-75 1 0176 0176 PC2WH-177 1 0.290 0.290 1.060 Total 4 Maximum 2.5 Amps 2.018 Totals Maximum 10 Amps 8.292 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 594 699 765 680 Actual Wire run Distance 550 450 425 550 Voltage Drop for 14 AWG wire 3 705 2.575 2.223 3.235 Circuit 18 Circuit 2B Circuit 3B Circuit 48 Max Wire Run Distance For AWG 14 562 549 623 615 Actual Wire run Distance 425 425 425 500 Voltage Drop for 14 AWG wire 3 027 3 097 2 730 3 254 Voltage Drop = 2 * Wire Run Distance' 3 07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line Standby Amp Hrs 5.400 Alarm Current 8.467 Alarm Current 5 Min 0 703 Battery Size Required with 5 Min Alarm Time and 20% Reserve 7.323 Battery Size Supplied 18 A H I Part.Number Standby Battery Calculations Altronix AL1OO2ULADA #5 JCPenney Seattle, WA 98188 Description - Standby � �Current Atami ' Current Ouarttity Par:Device All bevicea Per.Device All' Devices AL1002UL-ADA-J ADA Power Booster 10A@24VDC 1 0090 0.090 0.175 0.175 Auxiliary devices Maxirrwm'3 Amps Total Aux current 0 000 0 000 Max 3 Amps 0.090 0 000 0.000 Alarm 0.175 Signal Circuits Circuit' Circuit 1A PC2W-30 SCW-30 SCW-75 ; Deyice ann. • ,.Current.'. Chiari*.. Per Device ;.;All Devices 5 0.107 0.535 3 0.094 0.282 1 0.158 0.158 0.000 0.975 Circuit 113 PC2W-30 PC2W-15 PC2W-75 SCW-30 SCW-15 1 1 1 4 2 0.107 0.079 0.176 0.094 0.066 0.107 0 079 0.176 0 376 0 132 0 870 Total 1 Maximum 2.5 Amps 1 845 Circuit 2A PC2W-30 PC2W-75 PC2W-15 SCW-15 SCW-75 1 1 2 1 2 0 107 0.176 0.079 0.066 0.158 0 107 0 176 0 158 0 066 0.316 0.823 Circuit 2B PC2W-75 SCW-30 2 2 0.176 0 094 0 352 0 188 0.000 0 000 0.540 Total 2 Maximum 2 5 Amps 1.363 Circuit 3A 0.000 0.000 0.000 0 000 0.000 Circuit 38 0.000 0 000 0.000 0.000 Total 3 Maximum 2.5 Amps 0 000 Circuit 4A 0 000 0.000 0.000 0.000 0 000 Circuit 4B 0 000 0 000 0 000 0.000 Total 4 Maximum 2.5 Amps 0 000 Totals Maximum 10 Amps 3.208 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 668 792 Actual Wire run Distance 450 375 Voltage Drop for 14 AWG wire 2.694 1.895 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 749 1206 Actual Wire run Distance 400 400 Voltage Drop for 14 AWG wire 2 137 1.326 Voltage Drop = 2 Wire Run Distance 3.07 Ohms Per 1000 It 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts and a minimum voltage at the end of line of 16 Volts. Calculations assume that all devices are at the end of the line Standby Hours 60 Standby Battery Draw 0 090 Standby Amp Hrs 5.400 Alarm Current 3.383 Alarm Current 5 Min 0 281 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 6 817 Battery Size Supplied 18 A H +' PO Box 3932 Seattle WA 98124-3932 206-234-5700 Tel 206-244-1957 Fax Fire Com NW, Inc. Battery Calculation Work Sheet Project: JC Penney Storage TI 633 Southcenter Mall Tukwila WA 98188 This project consists of a new fire alarm system for a tenant improvement for a 'S' occupancy space that is fully sprinklered. This scope of work will include installing a new fire alarm control panel, initiating and signaling devices. This work sheet is for the fire alarm panel and the connected devices. Qty Part # and description Supervised Current mA Alarm Current mA 1 07024 Radionics FACP 269 380 1 D282 Smoke detector 0.0036 0.0036 3 PC Horn strobe — ceiling mount 0 792 3 SC Strobe — ceiling mount 0 690 Subtotal 269 1862 Total battery power hours x24 x.083 Subtotal 6456 155 Safety factor - 10% +646 + 16 Total 7102 ma 171 ma Total Current Required 7273 ma or 7.3 amps Battery size used: 2ea- 12volt, 12amp Nyco Integrated Security Fire Alarm Submittal Prepared for JCPenney 0696-5 1249 SOUTHCENTER MALL SEATTLE, WA 98188 Submitted By: Tyco Integrated Security 11824 No Creek Parkway Bothell, WA 98011 (206) 624-3103 Designed By: Tyco Integrated Security National Accounts Sales & Support 120 West Park Drive Birmingham, AL 35211 Dusty Jones Phone (205) 940-7337 Fax (205) 942-4943 NICET Level III 120752 System Outline I. Location JCPenney 0696-5 1249 SOUTHCENTER MALL SEATTLE, WA 98188 II. Codes A. NFPA 72 Fire Alarm Code B. NFPA 70 National Electrical Code C. Local, City, or State Codes III. Control A. 1 MS9600 Fire Alarm Control B. 1 DACT-UD Dual Line Dialer C. 5 AL1002UL-ADA-J ADA Power Booster 10A@24VDC D. 1 AL4000LX Power Supply 4A @ 12 or 3A @ 24VDC IV. Fire Alarm Initiating Devices A. 6 SD355 Smoke Detector Photo B. 25 D350PL Duct Smoke Detector C. 4 Water Flow Connection Only, Provided by Others D. 9 Tamper Switch Connection Only, Provided by Others E. 2 Air Pressure Connection Only, Provided by Others V. Fire Alarm Indicating Devices A. 1 LCD -80F Annunciator LCD B. 2 PC2WH-185 Ceiling Horn strobe WHITE 24VDC 185CD C. 42 PC2WH-177 Ceiling Horn strobe WHITE 24VDC 177CD D. 2 PC2WH-135 Ceiling Horn strobe WHITE 24VDC 135CD E. 3 PC2W-115 Ceiling Horn strobe WHITE 24VDC 115CD F. 27 PC2W-75 Ceiling Horn strobe WHITE 24VDC 75CD G. 46 PC2W-30 Ceiling Horn strobe WHITE 24VDC 30CD H 3 PC2W-15 Ceiling Horn strobe WHITE 24VDC 15CD I. 2 P2W-110 Wall Horn strobe WHITE 24VDC 110CD J. 6 P2W-75 Wall Horn strobe WHITE 24VDC 75CD K. 4 P2W-30 Wall Horn strobe WHITE 24VDC 30CD L. 4 SCWH-177 Ceiling Strobe WHITE 24VDC 177CD M. 9 SCW-115 Ceiling Strobe WHITE 24VDC 115CD N. 17 SCW-75 Ceiling Strobe WHITE 24VDC 75CD O. 45 SCW-30 Ceiling Strobe WHITE 24VDC 30CD P. 9 SCW-15 Ceiling Strobe WHITE 24VDC 15CD Q. 2 SW -30 Wall Strobe WHITE 24VDC 30CD R. 2 SW -15 S. 1 P2RK-110 VI. Zones All devices are addressable with there own address 1-159 detector addresses 1-159 module addresses SLC Loop is style 4 VII. Wiring All Circuits and Wring Shall be "Power Limited" SLC Circuits Shall be 16/2 Shielded U.L. FPLP Cable Initiating Zones Shall be 18/2 or 18/4 U.L. FPLP Cable Indicating Circuits Shall be 14/2 U.L. FPLP Cable System Ground Shall be 14 THWN Green Conductor Under Ground and Outside Wire shall be 14 THWN in Approved Raceway VIII. Listings A. All Equipment Shall Be U.L. Listed and Compatible IX. Power Supply A. Primary - 110 VAC Dedicated 20 Amp Circuit B. Secondary - 25 Amp Hour Battery X. Alarm Supervision A. Human B. Remote Station Installing Branch/Contractor ADT Fire & Security ADT Tyco Fire & Security 14200 E Exposition Blvd. 11824 No Creek Parkway Aurora, CO 80012 Bothell, WA 98011 (303) 338-8200 (206) 624-3103 S994-183 UUFX Sequence of Operation Annunciate alarm signal at control panel and remote annunciator Annunciate supervisory signal at control pane and remote annunciator Annunciate trouble signal at control pane and remote annunciator Transmits alarm signal to UL listed monitoring center Transmits supervisory signal to UL listed monitoring center Transmits trouble to UL listed monitoring center. Shuts down associated AHU/RTU Release Security Gate Release Shoe Stock Door Holders Turn on Lights through EMS Light Control Activates interior horns and strobes Activates exterior horn strobe Srinkler system Water flow x x x x x x x Valve tamper x x Air Pressure High x x Air Pressure Low x x x x x x x Manual pull station x x x x x x Smoke detectors at panel x x x x x x Duct smoke detectors x x x Abnormal circuit or device x x Standby Battery Calculations FireLite MS9600 JCPenney SEATTLE, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All Devices MS9600 Fire Alarm Control 1 0.120000 0.120000 0.170000 0.170000 DACT-UD Dual Line Dialer 1 0.100000 0.100000 0.132000 0.132000 LCD -80F Annunciator LCD 1 0.025000 0.025000 0.064000 0.064000 SD355 Smoke Detector Photo 6 0.000300 0.001800 0.006500 0.039000 MDF -300 Monitor Module Dual Input 6 0.000750 0.004500 0.006400 0.038400 MMF-300 Monitor Module Single input 5 0.000400 0.002000 0.005100 0.025500 MMF-301 Monitor Module Small 8 0.000375 0.003000 0.000375 0.003000 CRF -300 Control Module Relay 16 0.000270 0.004320 0.006500 0.104000 D350PL Duct Smoke Detector 25 0.000300 0.007500 0.000300 0.007500 RTS451 KEY Remote test Switch 25 0.012000 0.300000 0.012000 0.300000 0.000000 0.000000 0.000000 0.000000 Total Aux current Max 3 Amps 0.568 Alarm 0.883 Signal Circuits • Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1 AL1002UL-ADA-J 0.175 0.000 0.000 0.000 0.000 Total 1 Maximum 2.5 Amps 0.000 Circuit 2 AL1002UL-ADA-J 0.175 0.000 0.000 0.000 0.000 Total 2 Maximum 2.5 Amps 0.000 Circuit 3 P2RK-110 1 0.212 0.212 0.000 0.000 0.000 Total 3 Maximum 2.5 Amps 0.212 Circuit 4 0.000 0.000 0.000 0.000 Total 4 Maximum 2.5 Amps 0.000 Totals Maximum 6 Amps 0.212 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Max Wire Run Distance For AWG 14 3073 Actual Wire run Distance 100 Voltage Drop for 14 AWG wire 0.130 Voltage Drop = 2 * Wire Run Distance * 3.07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit / 1000 Standby Hours 60 Standby Battery Draw 0.568 Standby Amp Hours Req. 14.700 Alarm Minutes 5 Alarm Battery Draw 1.095 Alarm Amp Hours Req. 0.091 Battery Size Required with 0.56812 Standby hours, 5 Alarm minutes and 20% Reserve 17.677 ' 'Battery Size Supplied 25 A.H. JCPenney Standard Fire Alarm Zoning FireLite MS9600 Reporting Zone # Address Number Device Software Zone Software Zone Software Zone NAC #1 System sensor Sync 1 2 NAC #2 System sensor Sync 1 2 NAC #3 System sensor Sync 1 2 NAC #4 System sensor Sync 1 2 Relay #1 Alarm 1 2 Relay #2 Trouble 4 Relay #3 Supervisory 3 Loop #1 Module Addresses 160 1 Box Tampers Control 3 161 2 Box Tampers Battery Box 3 163 4 Water flow #1 1 164 5 Sprinkler Tamper Switch #1 3 165 6 Water flow #2 1 166 7 Sprinkler Tamper Switch #2 3 167 8 Water flow #3 1 168 9 Sprinkler Tamper Switch #3 3 169 10 Sprinkler Tamper Switch #4 3 170 11 Sprinkler Tamper Switch #5 3 171 12 Sprinkler Tamper Switch #6 3 172 13 Dry Water flow #1 1 173 14 Dry Sprinkler Tamper Switch #1 3 174 15 Air Pressure Switch High 3 175 16 Air Pressure Switch Low 1 176 17 Outside PIV #1 3 177 18 Outside PIV #2 3 178 19 Box Tampers Power Supply 3 179 20 Box Tampers Power Expander #1 3 180 21 Box Tampers Power Expander #2 3 181 22 Box Tampers Power Expander #3 3 182 23 Box Tampers Power Expander #4 3 183 24 Box Tampers Power Expander #5 3 228 69 Security Gate Release 1 2 229 70 Security Gate Release 1 2 230 71 Door Holders Release 1 2 233 74 EMS Light control 1 2 252 93 HVAC #1 Shutdown 41 253 94 HVAC #2 Shutdown 42 254 95 HVAC #3 Shutdown 43 255 96 HVAC #4 Shutdown 44 256 97 HVAC #5 Shutdown 45 257 98 HVAC #6 Shutdown 46 258 99 HVAC #7 Shutdown 47 259 100 HVAC #8 Shutdown 48 260 101 HVAC #9 Shutdown 49 261 102 HVAC #10 Shutdown 50 262 103 HVAC #11 Shutdown 51 263 104 HVAC #12 Shutdown 52 272 113 EOL Power Supervision MMF 61 273 114 EOL Power Supervision MMF 62 Detector Addresses 001 1 Smoke Detector at panel 2 002 2 Smoke Detector at Penthouse 2 003 3 Smoke Detector at Door Holders 2 004 4 Smoke Detector at Door Holders 2 005 5 Smoke Detector at Door Holders 2 006 6 Smoke Detector at Door Holders 2 021 21 AHU #1 Supply Duct Detector 3 41 022 22 AHU #1 Return Duct Detector 3 41 023 23 AHU #2 Supply Duct Detector 3 42 024 24 AHU #2 Return Duct Detector 3 42 025 25 AHU #3 Supply Duct Detector 3 43 026 26 AHU #3 Return Duct Detector 3 43 027 27 AHU #4 Supply Duct Detector 3 44 028 28 AHU #4 Return Duct Detector 3 44 029 29 AHU #5 Supply Duct Detector 3 45 030 30 AHU #5 Return Duct Detector 3 45 031 31 AHU #6 Supply Duct Detector 3 46 032 32 AHU #6 Return Duct Detector 3 46 033 33 AHU #7 Supply Duct Detector 3 47 034 34 AHU #7 Return Duct Detector 3 47 035 35 AHU #8 Supply Duct Detector 3 48 036 36 AHU #8 Return Duct Detector 3 48 037 37 AHU #9 Supply Duct Detector 3 49 038 38 AHU #9 Return Duct Detector 3 49 039 39 AHU #10 Supply Duct Detector 3 50 040 40 AHU #10 Return Duct Detector 3 50 041 41 AHU #11 Supply Duct Detector 3 51 042 42 AHU #11 Return Duct Detector 3 51 043 43 AHU #12 Supply Duct Detector 3 52 044 44 AHU #12 Return Duct Detector 3 52 Standby Battery Calculations Altronix AL4000LX JCPenney SEATTLE, WA 98188 Part Number Standby Current Alarm Description Quantity Per Device All Devices Per Device Current All Devices AL4000LX Power Supply 4A @ 12 or 3A @ 24VE 1 0.060 0.060 0.060 0.060 Auxiliary devices Maximum 3 Amps A77 -716B Power Supervisory Relay Total Aux current 2 0.019 0.038 0.000 Max 3 Amps 0.098 0.019 Alarm I 0.038 0.000 0.098 Standby Hours 24 Standby Battery Draw 0.098 Standby Amp Hours Req 2.352 Alarm Minutes 5 Alarm Battery Draw 0.098 Alarm Amp Hours Req 0.008 Battery Size Required with 24 Standby hours, 5 Alarm minutes and 20% Reserve 2.832 (Battery Size Supplier 7 A.H. Standby Battery Calculations Altronix AL1 OO2ULADA #1 JCPenney SEATTLE, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All Deices AL1002UL-ADAJ ADA Power Booster 10A©24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1A PC2W30 2 0.107 0.214 SCW30 3 0.094 0.282 PC2W-75 1 0.176 0.176 SCW-75 1 0.158 0.158 PC2WH-135 1 0.245 0245 1.075 Circuit 1B PC2W-75 3 0.176 0.528 SCW-75 1 0.158 0.158 PC2W30 2 0.107 0.214 SCW30 2 0.094 0.188 1.088 Total 1 Maximum 2.5 Amps 2.163 Circuit 2A PC2WH-185 2 0.297 0.594 PC2WH-177 1 0.290 0.290 PC2WH-135 1 0.245 0245 0.000 1.129 Circuit 2B PC2WH-177 3 0.290 0.870 SCW-115 1 0.210 0.210 0.000 1.080 Total 2 Maximum 2.5 Amps 2.209 Circuit 3A PC2WH-177 3 0.290 0.870 SCW-115 1 0.210 0.210 SCW-75 1 0.158 0.158 0.000 1.238 Circuit 38 SCW-30 3 0.094 0282 PC2W30 1 0.107 0.107 PC2W-75 2 0.176 0.352 PC2WH-177 1 0.290 0.290 1.031 Total 3 Maximum 2.5 Amps 2.269 Circuit 4A PC2WH-177 2 0290 0.580 SCW-115 1 0.210 0.210 PC2W-75 1 0.176 0176 SCW30 1 0.094 0.094 1.060 Circuit 4B SCW-30 1 0.094 0.094 PC2W30 1 0.107 0.107 PC2W-75 2 0.176 0.352 SCW-75 3 0.158 0.474 1.027 Total 4 Maximum 2.5 Amps 2.087 Totals Maximum 10 Amps 8.728 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 606 577 526 615 Actual Wire run Distance 375 400 350 375 Voltage Drop for 14 AWG wire 2.475 2.773 2.660 2.441 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 599 603 632 634 Actual Wire run Distance 525 300 550 550 Voltage Drop for 14 AWG wire 3.507 1.989 3.482 3.468 Voltage Drop = 2' Wire Run Distance' 3.07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hours Req. 5.400 Alarm Minutes 5 Alarm Battery Draw 8.903 Alarm Amp Hours Req. 0.742 Battery Size Required with 60 Standby hours, 5 Alarm minutes and 20% Reserve 7.370 Battery Size Supplied 18 A.H. Standby Battery Calculations Altronix AL1 002ULADA #2 JCPenney SEATTLE, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All Devices AL1002UL-ADAJ ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device All Deices Circuit 1A SCW-30 5 0.094 0.470 SCW-75 1 0158 0.158 PC2W30 1 0.107 0.107 PC2W-75 1 0.176 0.176 SCW-15 1 0.066 0.066 SCW-115 1 0.210 0.210 1.187 Circuit 1B PC2WH-177 1 0.290 0290 PC2W30 1 0.107 0.107 SCW30 2 0.094 0.188 SCW-15 1 0.066 0.066 SCW-75 2 0.158 0.316 0.967 Total 1 Maximum 2.5 Amps 2.154 Circuit 2A SCW-30 4 0.094 0.376 PC2W30 2 0.107 0.214 SCW-75 1 0.158 0.158 0.748 Circuit28 PC2W-30 1 0.107 0.107 SW30 2 0.094 0.188 P2W30 4 0.107 0.428 SW -15 2 0.066 0.132 0.855 Total 2 Maximum 2 5 Amps 1.603 Circuit 3A PC2WH-177 3 0.290 0.870 PC2W-75 1 0.176 0.176 SCW30 1 0.094 0.094 1.140 r Circuit 3B SCWH-177 2 0.281 0.562 PC2W-115 1 0.218 0 218 PC2WH-177 2 0.290 0.580 0.000 1.360 Total 3 Maximum 2.5 Amps 2.500 Circuit4A PC2WH-177 4 0.290 1.160 0.000 0.000 1.160 Circuit 4B PC2WH-177 2 0.290 0.580 PC2W30 3 0.107 0.321 SCW-75 1 0.158 0.158 0.000 1.059 Total 4 Maximum 2 5 Amps 2.219 Totals Maximum 10 Amps 8.476 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 549 871 571 562 Actual Wire run Distance 425 525 425 350 Voltage Drop for 14 AWG wire 3.097 2.411 2.975 2.493 Circuit 18 Circuit 28 Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 674 762 479 615 Actual Wire run Distance 450 500 350 525 Voltage Drop for 14 AWG wire 2.672 2.625 2.923 3.414 Voltage Drop = 2' Wire Run Distance' 3.07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hours Req. 5.400 Alarm Minutes 5 Alarm Battery Draw 8.651 Alarm Amp Hours Req. 0.721 Battery Size Required with 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 Battery Size Supplied 18 A.H. Standby Battery Calculations Altronix AL1002ULADA #3 JCPenney SEATTLE, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All Devices AL1002UL-ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1A PC2W-30 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 1.031 Circuit 1B PC2W-30 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 1.031 Total 1 Maximum 2.5 Amps 2.062 Circuit 2A PC2WH-177 2 0290 0.580 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 SCWH-177 1 0.281 0.281 1.131 Circuit 2B PC2WH-177 4 0.290 1.160 0.000 0.000 0.000 1.160 Total 2 Maximum 2.5 Amps 2.291 Circuit 3A PC2W-75 2 0.176 0.352 PC2W-30 4 0.107 0.428 SCW-15 2 0.066 0.132 0.000 0.912 Circuit 3B PC2W-75 4 0.176 0.704 PC2W-30 5 0.107 0 535 0.000 0.000 1.239 Total 3 Maximum 2.5 Amps 2.151 Circuit 4A P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 0 000 0.000 0.740 Circuit4B P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 0.000 0.000 0.740 Total 4 Maximum 2.5 Amps 1.480 Totals Maximum 10 Amps 7.984 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 632 576 714 880 Actual Wire run Distance 550 475 450 550 Voltage Drop for 14 AWG wire 3 482 3 299 2.520 2.499 Circuit 18 Circuit 2B Circuit 3B Circuit 4B Max Wre Run Distance For AWG 14 632 562 526 880 Actual Wre run Distance 575 350 450 550 Voltage Drop for 14 AWG wire 3.640 2.493 3.423 2.499 Voltage Drop = 2' Wre Run Distance' 3.07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hours Req. 5.400 Alarm Minutes 5 Alarm Battery Draw 8.159 Alarm Amp Hours Req. 0.680 Battery Size Required with 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 (Battery Size Supplied 18 A.H. I Standby Battery Calculations Altronix AL1002ULADA #4 JCPenney SEATTLE, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All Devices AL1002UL-ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1A SCWH-177 1 0.281 0.281 SCW-75 2 0.158 0.316 SCW-30 3 0.094 0.282 PC2W-115 1 0.218 0.218 1.097 Circuit 1B PC2WH-177 4 0.290 1.160 0.000 0.000 0.000 1.160 Total 1 Maximum 2.5 Amps 2.257 Circuit 2A PC2WH-177 1 0.290 0.290 PC2W-30 2 0.107 0.214 SCW-115 1 0.210 0210 PC2W-115 1 0.218 0.218 0.932 Circuit 2B PC2WH-177 3 0.290 0.870 SCW-115 1 0.210 0.210 PC2W-30 1 0.107 0.107 0.000 1.187 Total 2 Maximum 2.5 Amps 2.119 Circuit 3A PC2WH-177 1 0.290 0.290 SCW-115 1 0.210 0.210 PC2W-75 2 0.176 0.352 0.852 Circuit 38 PC2WH-177 3 0 290 0 870 PC2W-75 1 0.176 0.176 0.000 1.046 Total 3 Maximum 2.5 Amps 1.898 Circuit 4A PC2WH-177 1 0.290 0.290 SCW-115 1 0.210 0.210 PC2W-75 1 0.176 0.176 SCW-30 3 0.094 0.282 0.958 Circuit 48 SCW-115 1 0.210 0.210 SCW-15 2 0.066 0.132 SCW-30 1 0.094 0.094 SCW-75 1 0.158 0.158 PC2W-75 1 0.176 0.176 PC2W1-t-177 1 0.290 0.290 1.060 Total 4 Maximum 2 5 Amps 2.018 Totals Maximum 10 Amps 8.292 _ . Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wre Run Distance For AWG 14 594 699 765 680 Actual Wre run Distance 550 450 425 550 Voltage Drop for 14 AWG wire 3.705 2.575 2.223 3.235 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wre Run Distance For AWG 14 562 549 623 615 Actual Wre run Distance 425 425 425 500 Voltage Drop for 14 AWG wire 3.027 3.097 2.730 3 254 Voltage Drop = 2' Wre Run Distance' 3.07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hours Req. 5.400 Alarm Minutes 5 Alarm Battery Draw 8.467 Alarm Amp Hours Req. 0.706 Battery Size Required with 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 I (Battery Size Supplied 18 A.H. Standby Battery Calculations Altronix AL1002ULADA #5 JCPenney SEATTLE, WA 98188 Standby Current Part Number Description Quantity Per Device All Devices Alarm Current Per Device All Devices AL1002UL-ADA-J ADA Power Booster 10Agg24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 Total Aux current Max 3 Amps 0.090 0.000 0.000 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1A PC2W-30 5 0.107 0.535 SCW-30 3 0.094 0.282 SCW-75 1 0.158 0.158 0.000 0.975 Circuit 1B PC2W-30 1 0.107 0.107 PC2W-15 1 0.079 0.079 PC2W-75 1 0.176 0.176 SCW-30 4 0.094 0.376 SCW-15 2 0.066 0.132 0.870 Total 1 Maximum 2.5 Amps 1.845 Circuit 2A 0.000 PC2W-75 1 0.176 0.176 PC2W-15 2 0.079 0.158 SCW-15 1 0.066 0.066 SCW-75 2 0.158 0 316 0.716 Circuit 2B PC2W-75 2 0.176 0.352 SCW-30 2 0.094 0.188 0.000 0.000 0.540 Total 2 Maximum 2.5 Amps 1,256 Circuit 3A 0.000 0.000 0.000 0.000 0.000 Circuit 3B 0.000 0.000 0.000 0.000 Total 3 Maximum 2.5 Amps 0.000 Circuit 4A 0.000 0.000 0.000 0.000 0.000 Circuit 4B 0.000 0.000 0.000 0.000 Total 4 Maximum 2.5 Amps 0.000 Totals Maximum 10 Amps 3.101 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wre Run Distance For AWG 14 668 910 Actual Wre run Distance 450 375 Voltage Drop for 14 AWG wire 2.694 1.649 Circuit 1B Circuit 2B Circuit 3B Circuit 48 Max Wre Run Distance For AWG 14 749 1206 Actual Wre run Distance 400 400 Voltage Drop for 14 AWG wire 2.137 1.326 , Voltage Drop = 2 *Wre Run Distance' 3.07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hours Req. 5.400 Alarm Minutes 5 Alarm Battery Draw 3.276 Alarm Amp Hours Req. 0.273 Battery Size Required with 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 I 'Battery Size Supplied 18 A.H. System Outline Location JCPenney 0696-5 1200 Southcenter Mall Seattle, WA 98188 11. Codes A. 2002 NFPA 72 Chapters 1-10 as Applicable(Remote Station) B. 2002 NEC Articles 250, 725, 760 C. Local, City, State III. Control A. 1 MS9600 Fire Alarm Control B. 1 DACT-UD Dual Line Dialer C. 5 AL1002UL-ADA-J ADA Power Booster 10A@24VDC D. 1 AL4000LX Power Supply 4A © 12 or 3A @ 24VDC IV. Fire Alarm Initiating Devices A. 1 BG-12LX Manual Pull Station Addressable B. 17 SD355 Smoke Detector Photo C. 9 H355R Heat Detector Rate of Rise D. 25 D350PL Duct Smoke Detector E. 4 Water Flow Connection Only, Provided by Others F. 9 Tamper Switch Connection Only, Provided by Others G. 2 Air Pressure Connection Only, Provided by Others V. Fire Alarm Indicating Devices A. 1 LCD -80F Annunciator LCD B. 46 PC2WH-177 Ceiling Horn strobe white 24VDC 177CD C. 5 PC2W-115 Ceiling Horn strobe white 24VDC 115CD D. 27 PC2W-75 Ceiling Horn strobe white 24VDC 75CD E. 46 PC2W-30 Ceiling Horn strobe white 24VDC 30CD F. 3 PC2W-15 Ceiling Horn strobe white 24VDC 15CD G. 2 P2W-110 Wall Horn strobe white 24VDC 110CD H 6 P2W-75 Wall Horn strobe white 24VDC 75CD I. 4 P2W-30 Wall Horn strobe white 24VDC 30CD J. 4 SCWH-177 Ceiling Strobe white 24VDC 177CD K. 8 SCW-115 Ceiling Strobe white 24VDC 115CD L. 18 SCW-75 Ceiling Strobe white 24VDC 75CD M. 44 SCW-30 Ceiling Strobe white 24VDC 30CD N. 9 SCW-15 Ceiling Strobe white 24VDC 15CD O. 2 SW -30 Wall Strobe white 24VDC 30CD P. 2 SW -15 Wall Strobe white 24VDC 15CD Q. 1 P2RK-110 Wall Horn strobe RED 24VDC Weather Proof VI. Zones All devices are addressable with there own address 1-159 detector addresses 1-159 module addresses SLC Loop is style 4 VII. Wiring All Circuits and Wiring Shall be "Power Limited" SLC Circuits Shall be 16/2 Shielded U.L. FPLP Cable Initiating Zones Shall be 18/2 or 18/4 U.L. FPLP Cable Indicating Circuits Shall be 14/2 U.L. FPLP Cable System Ground Shall be 14 THWN Green Conductor Under Ground and Outside Wire shall be 14 THWN in Approved Raceway VIII. Listings A. All Equipment Shall Be U.L. Listed and Compatible IX. Power Supply A. Primary - 110 VAC Dedicated 20 Amp Circuit B. Secondary - 25 Amp Hour Battery X. Alarm Supervision A. Human B. Remote Station Installing Branch/Contractor ADT Fire & Security ADT Tyco Fire & Security 14200 E Exposition Blvd. 11824 No Creek Parkway Aurora, CO 80012 Bothell, WA 98011 (303) 338-8200 (206) 624-3103 S994-183 UUFX Sequence of Operation egoils wog JOIJ9IXO salengoy sagals pue swot' JOU8Iu1 selengoy IoJluoa 4116!1 SINS 1.16nojyl sly6!i uo wnl se lu'S Jooa eo!ljp asealaa amp AlunoeS eseelaa du; lungs Jolenala elenlloy J00I1 3leuja;le of Jolena!a slleoaa moll AJewud of Jolenale slleoaa 412!/fHV pale!oosse uMop sings Jeluao 6uuol!uow pals!l -in 01 email spwsuejl Jelueo 6uuol!uow pals) in 01leu6!s kJos!AJ3dns sl!wsueJl Jaluao 6uuol!uow pals!I in 04 leu6!s wJele sl!wsueJl Jole!ounuue elowai pue eued loJluoo le leu6!s email ele!ounuuy JOIe!Ounuue 940WGJ pue eued laluoo le leu6!s AJos!AJadns ele!ounuuy JOleIOunuue elowei pue hued loJluoo le leu6!s mem ele!ounuuy x x x x K IOC k. jCxX XX XX 1,C )0,c. x x x x XXXX XXX XXXX XXX x x x x xxxx xxx xxxx x x x x x x x XXXX XXX XXXX XXX x x x x XXXX XXX XXXX XXX x x x x x x x x x x X X x x x x x x x x x x x x x x x x x x XXXX XXX x x x x x x x x XXXX XXX XXXX XXX (Sprinkler system Water flow Valve tamper Air Pressure High Air Pressure Low 'Manual pull station 1 Smoke detectors at panel _ Duct smoke detectors Passenger Elevator 'Smoke Detectors Lower level lobb Upper level lobby !Machine room Top of shaft Heat Detector Top of shaft 'Machine room Bottom of shaft Freight Elevator (Smoke detectors Lower level lobby Upper level lobby Machine room Top of shaft (Heat Detector Top of shaft Machine room Bottom of shaft Abnormal circuit or device Standby Battery Calculations FireLite MS9600 JCPenney Seattle, WA 98188 . .. , .... .. .. . ... . . . ..... , . . , . ......... . .... . ... .. . .. . •. • .. . ... . . . . . .... ... ..... ••• . . . . . . .........,... .............. ... . $1000y::::::::.: (604:::.:•:. AlOri.6.: : :...: :.:•Curr.00t: :.:• .-. ". ............ .......-...- • .. " .. . .. . .... ...... ... .....". -.." . .........."...-.. . ........... :••• .. : :..66.iirifiaii.:.:.:.:.:.:...:.:.:...:•:.: , . .....: Oupti • .: : : Per Device :::::N:ppyjcp..,::::pr.pv.kce:::::0:ppvicgs PariNiititier6 .. . ...... ....... ,.. .... . MS9600 Fire Alarm Control ic 1 0.120000 0.120000 0.170000 0.170000 DACT-UD Dual Line Dialer 1 0.100000 0.100000 0.132000 0.132000 LCD -80F Annunciator LCD 1 0.025000 0.025000 0.064000 0.064000 SD355 Smoke Detector Photo 17 0.000300 0.005100 0.000300 0.005100 H355R Heat Detector Rate of Rise x 9 0.000300 0.002700 0.000300 0.002700 MDF -300 Monitor Module Dual Input 6 0.000750 0.004500 0.000750 0.004500 MMF-300 Monitor Module Single input 3 0.000400 0.001200 0.000510 0.001530 MMF-301 Montior Module Small 8 0.000375 0.003000 0.000375 0.003000 CRF -300 Control Module Relay 25 0.000270 0.006750 0.000510 0.012750 , D350PL Duct Smoke Detector 25 0.000300 0.007500 0.000300 0.007500 RTS451KEY Remote test Switch 25 0.000000 0.000000 0.008000 0.200000 0.000000 0.000000 Total Aux current Max 3 Amps 0.276 Alarm 0.603 Signal Circuits ---------- .... . .. .... • :::44-ii:H*i:.:::. • • • . ... ...• .... .. Circuit ••••••• - • • • :::: ::PO*0•:.:.: : :.: : :.:.: : :::::::PWtitY:.: . ::0.0010:::::Alf.00vi0e$:. Circuit 1 Ai1002. UL -ADA -J 0.175 0.000 0.000 0.000 0.000 Total 1 Maximum 2.5 Amps 0.000 Circuit 2 AL1002UL-ADA-J 0.175 0.000 0.000 0.000 0.000 Total 2 Maximum 2.5 Amps 0.000 Circuit 3 P2RK-110 1 0.212 0.212 0.000 0.000 0.000 Total 3 Maximum 2.5 Amps 0.212 Circuit 4 0.000 0.000 0.000 0.000 Total 4 Maximum 2.5 Amps 0.000 Totals Maximum 6 Amps 0.212 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Max Wire Run Distance For AWG 14 3073 Actual Wire run Distance 100 Voltage Drop for 14 AWG wire 0.130 Voltage Drop = 2 * Wire Run Distance " 3.07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit / 100C Standby Hours 60 Standby Battery Draw 0.276 Standby Amp Hrs 16.545 Alarm Current 0.815 Alarm Current 5 Min 0.068 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 19.935 Battery Size Supplied 25 A.H. JCPenney Standard Fire Alarm Zoninc FireLite MS9600 4 Reporting Zone # Address Number Device Software Zone Software Zone Software Zone Software Zone Software Zone NAC #1 System sensor Sync 1 2 NAC #2 System sensor Sync 1 2 NAC #3 System sensor Sync 1 2 NAC #4 System sensor Sync 1 2 Relay #1 Alarm 1 2 Relay #2 Trouble 4 Relay #3 Supervisory 3 Loop #1 Module AddresseM 160 1 Box Tampers Control 3 161 2 Box Tampers Battery Box 3 163 4 Water flow #1 1 164 5 Sprinkler Tamper Switch #1 3 165 6 Water flow #2 1 166 7 Sprinkler Tamper Switch #2 3 167 8 Water flow #3 1 168 9 Sprinkler Tamper Switch #3 3 169 10 Sprinkler Tamper Switch #4 3 170 11 Sprinkler Tamper Switch #5 3 171 12 Sprinkler Tamper Switch #6 3 172 13 Dry Water flow #1 1 173 14 Dry Sprinkler Tamper Switch #1 3 174 15 Air Pressure Switch Higf• 3 175 16 Air Pressure Switch Low 1 176 17 Outside PIV #1 3 177 18 Outside PIV #2 3 178 19 Box Tampers Power Supply 3 179 20 Box Tampers Power Expander #1 3 180 21 Box Tampers Power Expander #2 3 181 22 Box Tampers Power Expander #k? 3 182 23 Box Tampers Power Expander #4 3 183 24 Box Tampers Power Expander #5 3 233 74 EMS Light control 1 2 236 77 Freight Elevator #1 shunt trig 10 237 78 Freight Elevator #1 Level 1 Recal 11 238 79 Freight Elevator #1 Level 2 Recal 12 239 80 Freight Elevator #1 Fire Hal 13 240 81 Passenger Elevator #1 shunt trig 20 241 82 Passenger Elevator #1 Level 1 Recal 21 242 83 Passenger Elevator #1 Level 2 Recal 22 243 84 Passenger Elevator #1 Fire Hal 23 244 85 Passenger Elevator #2 shunt trig 30 245 86 Passenger Elevator #2 Level 1 Recal 31 246 87 Passenger Elevator #2 Level 2 Recal 32 247 88 Passenger Elevator #2 Fire Hal 33 252 93 HVAC #1 Shutdown 41 253 94 HVAC #2 Shutdown 42 254 95 HVAC #3 Shutdown 43 255 96 HVAC #4 Shutdown 44 256 97 HVAC #5 Shutdown 45 257 98 HVAC #6 Shutdown 46 258 99 HVAC #7 Shutdown 47 259 100 HVAC #8 Shutdown 48 272 113 EOL Power Supervision MMF 61 273 114 EOL Power Supervision MMF 62 Detector Addresses 001 1 Smoke Detector at panel 2 002 2 Smoke Detector at Penthouse 2 021 21 AHU #1 Supply Duct.Detector 3 41 022 22 AHU #1 Return Duct Detector 3 41 023 23 AHU #2 Supply Duct Detector 3 42 024 24 AHU #2 Return Duct Detector 3 42 025 25 AHU #3 Supply Duct Detector 3 43 026 26 AHU #3 Return Duct Detector 3 43 027 27 AHU #4 Supply Duct Detector 3 44 028 28 AHU #4 Return Duct Detector 3 44 JCPenney Standard Fire Alarm Zoninc FireLite MS9600 4 Reporting Zone # Address Number Device Software Zone Software Zone Software Zone Software Zone Software Zone 029 29 AHU #5 Supply Duct Detector 3 45 030 30 AHU #5 Return Duct Detector 3 45 031 31 AHU #6 Supply Duct Detector 3 46 032 32 AHU #6 Return Duct Detector 3 46 033 33 AHU #7 Supply Duct Detector 3 47 034 34 AHU #7 Return Duct Detector 3 47 035 35 AHU #8 Supply Duct Detector 3 48 036 36 AHU #8 Return Duct Detector 3 48 065 65 Freight Elev Heat Detector Pit 2 10 066 66 Freight Elev Heat Detector Machine Roorr 2 10 067 67 Freight Elev Smoke Detector Machine Room 2 12 068 68 Freight Elev Smoke Detector 1st floor Lobby 2 12 069 69 Freight Elev Smoke Detector 2nd floor Lobby 2 11 071 71 Freight Elev Smoke Detector 3rd floor Lobby 2 11 072 72 Freight Elev Smoke Detector Top of shaft 2 11 073 73 Freight Elev Heat Detector Top of Shaft 2 10 076 76 Passenger Elev #1 Heat Detector Pit 2 20 077 77 Passenger Elev #1 Heat Detector Machine Roorr 2 20 078 78 Passenger Elev #1 Smoke Detector Machine Room 2 22 079 79 Passenger Elev #1 Smoke Detector Main floor Lobby 2 22 080 80 Passenger Elev #1 Smoke Detector 2nd floor Lobby 2 21 082 82 Passenger Elev #1 Smoke Detector 3rd floor Lobby 2 21 083 83 Passenger Elev #1 Smoke Detector Top of shaft 2 21 084 84 Passenger Elev #1 Heat Detector Top of Shaft 2 20 087 87 Passenger Elev #2 Heat Detector Pit 2 30 088 88 Passenger Elev #2 Heat Detector Machine Roorr 2 30 089 89 Passenger Elev #2 Smoke Detector Machine Room 2 32 090 90 Passenger Elev #2 Smoke Detector Main floor Lobby 2 32 091 91 Passenger Elev #2 Smoke Detector 2nd floor Lobby 2 31 093 93 Passenger Elev #2 Smoke Detector 3rd floor Lobby 2 31 094 94 Passenger Elev #2 Smoke Detector Top of shaft 2 31 095 95 Passenger Elev #2 Heat Detector Top of Shaft 2 _ 30 Standby Battery Calculations Altronix AL400ULX JCPenney Seattle, WA 98188 AlarmStandby ••••••••••••:'••••••:•:••••‘•;•:•••••:.:' ..:.:...•.•.•.: .....:. All DevIea Per Device All Dvis AL400ULX Power Supply 4A @ 12 or 3A @ 24VC 1 0.060 0.060 0.060 0.060 .................... A77 -716B Power Supervisory Relay 2 Total Aux current 0.019 0.038 0.000 Max 3 Amps 0.098 Standby Hours 24 Standby Battery Draw 0.098 Standby Amp Hrs 2.352 Alarm Current 0.098 Alarm Current 5 Mir 0.008 Battery Size Required with 5 Min. Alarm Time and 20% ReservE 2.832 cattery Size Supplier 7 A.H. 0.019 0.038 0.000 Alarm 0.098 Standby Battery Calculations Altronix AL1002ULADA #1 JCPenney Seattle, WA 98188 ....... . . . . . . . . . . . . '':::.:::: .:'::::•.:::::':::::::: .::•:•:•.:.•:•::.:.::::,•:•••.•:::::•:.:.:•'•:•.....•:•••:•'•'•:•:•:•'•'•:.:::•:':•:•Sta7107:::•:•::4rtePf.:::::MOri::::::::::0-iriOr*::::•: :::.:..'1°0ii: r.OrnOc.::- ' :::.0*.ri006 . ' :.: ' • ::. . :.: : : ' • : . • .:::: • :.6.14eii?iti,..:.:.:: • : ::FOr.bcivic:e.:. :.:All: 00.08:.: PO( 00,44:: MI Nyi* .: AL 1002UL-ADAni ADA Power Booster 1 ........ 1 0.090 0.090 0.175 0,175 Auxiliary:ileViiii 9.axitn'bin .5 Amps• .• .• .• *.••• • • • • - 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits :••::::•:•:•:•:: •::::•........................... ................... :::::••.A.Qprip:•::::: ••03Arrpnt::- rcuit:•:::: :: .::::N*9::::.:::::::::::.:: ::::chiOrkiii:.:.:-:..-: ::::.P Or. 09:vici?::::*If Devices Circuit 1/1k 'PC2W-30 2 0.107 0.214 . SCW-30 4 0.094 0.376 PC2W-75 1 0.176 0.176 ,PC2WH-177 2 0.290 0.580 1.346 Circuit 1B PC2W-75 3 0.176 0.528 SCW-75 • 2 0.158 0.316 PC2W-30, 2 0.107 0.214 0.000 • •:•:•:-• • . • .. - . :• . • : :-:•:•: : :•:-'•:•:•. .••••:•: 1 058 Total 1 Maximum 2.5 Amps 2.404 Circuit 2A PC2WH-177' 3 0.290 0.870 PC2W-115 ' 1 0.218 0.218 SCW-75 1 0.158 0.158 0.000 '''''''''''''''' " • ' 1.246 Circuit 2B PC2WH-177 3 0.290 0.870 PC2W-115 1 0.218 0.218 0.000 0.000 '•:•:•.• • :• .• :• .• :• •• • ' :• ' • ' • ''' • ' • '' 1.088 Total 2 Maximum 2.5 Amps 2.334 Circuit 3A PC2WH-177 3 0.290 0.870 SCW-115 1 0.210 0.210 SCW-75 1 0.158 0.158 0.000 . . . . . .................. . . . . ... ., . . . • •. •........• ' • '' - ''' • ' - '' • ' • ' •.......•..•..•.• • •.• • • .:. . . .... .; .:.; . 1.238 Circuit 3B SCW-30 3 0.094 0.282 PC2W-30 1 0.107 0.107 PC2W-75 2 0.176 0.352 PC2WH-177 1 0.290 0.290 " " " " ....... " ...... " ' • ' ............... • • ' • • • - ' Total 3 Maximum 2.5 Amps 2.269 Circuit 4A PC2WH-177 2 0.290 0.580 CW -115 1 0.210 0.210 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 . . • : • : -: . ' • : • ' • : : • : • I . • ' • I, : • l• I • I • I, I, : • :;..• : • : • : • • • : • : . : ..... . . : .1. : • • : • : • : • • • • : • : • : • : • : • : : : • : .. • .. - .... - .... • .. • • : - .. - . • ... : .. • : • .. • : • : • : • : • : • : • 1.060 Circuit 4B SCW-30 1 0.094 0.094 PC2W-30 1 0.107 0.107 PC2W-75 2 0.176 0.352 SCW-75 3 0.158 0.474 • :• '• '•:• :•:•:. • • • • • '• :• :• :• :-:• :• :-:• :• :• :• :•:, :•.• :•:-:•:• • '• '•:•:•:• :• :• . :•:•:•:•:•: • • :. .. • .... • ...... - .. • .. • :• :• : • • :. :•:• :• :• :• :• :• 1.027 Total 4 Maximum 2.5 Amps 2.087 Totals Maximum 10 Amps 9.094 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 484 523 526 615 Actual Wre run Distance ' 375 400 350 375 Voltage Drop for 14 AWG wire 3.099 3.060 2.660 2.441 Circuit 1B Circuit 28 Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 616 599 632 634 Actual Wire run Distance 525 300 550 550 Voltage Drop for 14 AWG wire 3.410 2.004 3.482 3.468 Voltage Drop 2 *Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AWG ' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 9.269 Alarm Current 5 Min 0.769 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 7.403 Battery Size Supplied 18 A.H. Standby Battery Calculations Altronix AL1OO2ULADA #2 JCPenney Seattle, WA 98188 • Standtiy:: 7:;Current:;:;ii:Alariri >: i :.Current:;.;.;. Part f umber:::::::::::' :Descriptio i:.:.:.:::::::::::::::::::::::%]uantitj!:;:::::::;:Per:Device:;:;:;M bevices : PerOevice:::AllOevices : AL1002UL-ADAJ ADA Power Booster 10Ai 24VDC 1 0.090 0.090 0.175 0.175 .... ..........................•i:AUxiharkdeJiwsMaicimom 8Amps•:}_.....•....._........•.. _......:..::... . 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits .. .:.;Alarm;.:.....Current.;. Ciicui ::::::::::::::::::::: bevice ::::::::::::::;' ': .�...�.•.�.�. ...l.......................................... antity;�;�;.;.;.;.;.;.;.:.:.:.;.:.;.;.;:::::::::::::;:RerDevice:;:;li1l:Deyices: Circuit 1A SCW-30 5 0.094 0.470 SCW-75 1 0.158 0.158 PC2W-30 1 0.107 0.107 PC2W-75 1 0.176 0.176 SCW-15 1 0.066 0.066 SCW-115 1 0.210 0.210 ............................................................................... 1.187 Circuit 1B PC2WH-177 1 0.290 0.290 SCW-30 2 0.094 0.188 SCW-15 1 0.066 0.066 SCW-75 2 0.158 0.316 ........... . .. ....... .. Total 1 Maximum 2.5 Amps 2.047 Circuit 2A SCW-30 4 0.094 0.376 PC2W-30 2 0.107 0.214 SCW-75 1 0.158 0.158 .............................. ............. ........... .. .........• ............ ... ............................. ........... .......... ... 0.748 Circuit 28 PC2W-30 1 0.107 0.107 SW-30 2 0.094 0.188 P2W30 4 0.107 0.428 SW-15 2 0.066 0.132 0.855 Total 2 Maximum 2.5 Amps 1.603 Circuit 3A PC2WH-177 3 0.290 0.870 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 0.000 ....... ... .. .......... ... .... ... .............. ... 1.140 Circuit 3B SCWH-177 2 0.281 0.562 PC2W-115 1 0.218 0.218 PC2WH-177 2 0.290 0.580 0.000 1.360 Total 3 Maximum 2.5 Amps 2.500 Circuit 4A PC2WH-177 4 0.290 1.160 0.000 0.000 .. .. ......................................... .............. ............... 1.160 Circuit 48 PC2WH-177 2 0.290 0.580 PC2W-30 3 0.107 0.321 SCW-75 1 0.158 0.158 0.000 .. ..... ........ .. .. ..................................................... 1.059 Total 4 Maximum 2.5 Amps 2.219 Totals Maximum 10 Amps 8.369 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wre Run Distance For AWG 14 549 871 571 562 Actual Wre run Distance 425 525 425 350 Voltage Drop for 14 AWG wire 3.097 2.411 2.975 2.493 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 758 762 479 615 Actual Wire run Distance 400 500 350 525 Voltage Drop for 14 AWG wire 2.112 2.625 2.923 3.414 Voltage Drop = 2 * Wire Run Distance' 3.07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 8.544 Alarm Current 5 Min 0.709 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 7.331 Battery Size Supplied 18 A.H. Standby Battery Calculations Altronix AL1O02ULADA #3 JCPenney Seattle, WA 98188 • '>:$tandby:;:'::::: Cue:':':' i sAairi':':''Current:;:;::: '.... •': atf ratie_;descpton;:•::::::::i::Quanty:;•;:;::;:Fer'Devic;:; All: bevri;:;:PerDee.AlOeic:' AL1002UL-ADA-J ADA Power Booster 10A,a 24VDC 1 0.090 0.090 0.175 0.175 .•i.AuxiliarydevicesMaximum. Amps ... .. ................ 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits - ..................... ' :.-:Alarm;.•.;. •..GLrrant.;. :::00:41t. I.:: :''':':':':t evice':':':':':':':::':':'.':'.Quaritit ': ice '::Per:De ':' *1): 00.14§: Circuit 1A PC2W-30 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 1.031 Circuit 1B PC2W-30 7 0.107 0.749 SCW30 3 0.094 0.282 0.000 0.000 1.031 Total 1 Maximum 2.5 Amps 2.062 Circuit 2A PC2WH-177 2 0.290 0.580 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 SCWH-177 1 0.281 ` 0.281 .• .. ....... 1.131 Circuit 2B PC2WH-177 4 0.290 1.160 0.000 0.000 0.000 1.160 Total 2 Maximum 2.5 Amps 2.291 Circuit 3A PC2W-75 2 0.176 0.352 PC2W-30 4 0.107 0.428 SCW-15 2 0.066 0.132 0.000 ..............•'''''........ . . . ..................................................... • Circuit 3B PC2W-75 4 0.176 0.704 PC2W-30 5 0.107 0.535 0.000 0.000 • • • • • ...................................................................................... 1.239 Total 3 Maximum 2.5 Amps 2.151 Circuit 4A P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 0.000 0.000 ....................................... ...... ........ 0.740 Circuit48 P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 0.000 0.000 ...• .• .......... ............................. 0.740 Total 4 Maximum 2.5 Amps 1.480 Totals Maximum 10 Amps 7.984 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wre Run Distance For AWG 14 632 576 714 880 Actual Wire run Distance 550 475 450 550 Voltage Drop for 14 AWG wire 3.482 3.299 2.520 2.499 Circuit 1B Circuit 2B Circuit 3B Circuit 48 Max Wire Run Distance For AWG 14 632 562 526 880 Actual Wre run Distance 575 350 450 550 Voltage Drop for 14 AWG wire 3.640 2.493 3.423 2.499 Voltage Drop = 2 * Wire Run Distance' 3.07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 8.159 Alarm Current 5 Min 0.677 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 7.293 I 'Battery Size Supplied 18 A.H. Standby Battery Calculations Altronix AL1002ULADA #4 JCPenney Seattle, WA 98188 ':' Standby::.;:;:;: Current:':;::.:Alarm •:: •:. . Cunent: •: •: •: ' ''lart:Number::. !::.:.::.Oescnption ;;:;:;.;:; ':':'`:'''':':':.: ' duantity:.:,:,::;:Per Dov pe ;:<;AI bevices;:.'Per Dey ce:.:;:Aliflevices": AL1002UL-ADAJ ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 .. ...... ... ......... AuxdiarkdevicesMaximum.Aaips.:."."......... ....... .....' • 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits ...........:.:.. .• •.;.;. .'.;Alarm;.."." . t.: . urren. e :..:.:"'C! ::: iiantrty>..:">::.»::.":... :.."'"' ""'•' ' ':':Per:DeviceiAl:"fie , . ....... .:,.Circuit•:" :.:::::............: :.:.".;:.t evrci(h Circuit 1A SCWH-177 1 0.281 0.281 SCW-75 2 0.158 0.316 SCW-30 3 0.094 0.282 PC2W-115 1 0.218 0.218 .. • • 1.097 ..... Circuit 18 PC2WH-177 4 0.290 1.160 0.000 0.000 0.000 ......... 1.160 Total 1 Maximum 2.5 Mips ' " ' 2 257 Circuit 2A PC2WH-177 1 0.290 0.290 PC2W-30 2 0.107 0.214 SCW-115 1 0.210 0.210 PC2W-1151 0.218 0.218 0.932 Circuit2B PC2WH-177 3 0.290 0.870 SCW-115 1 0.210 0.210 PC2W-30 1 0.107 0.107 0.000 ... ..... ..:• . .... .........•... .... ...................... 1.187 Total 2 Maximum 2.5 Amps 2.119 Circuit 3A PC2WH-177 1 0.290 0.290 SCW-115 1 0.210 0.210 PC2W-75 2 0.176 0.352 ... 0.852 ........... Circuit 3B PC2WH-177 0.290 0.870 PC2W-75 1 0.176 0.176 0.000 .. .... ..... ...... ..... 1.046 Total 3 Maximum 2.5 Amps 1 898 Circuit 4A PC2WH-177 1 0.290 0.290 SCW-115 1 0.210 0.210 PC2W-75 1 0.176 0.176 SCW-303 0.094 0.282 0.958 Circuit48 SCW-115 1 0.210 0.210 SCW-15 2 0.066 0.132 SCW-30 1 0.094 0.094 SCW-75 1 0.158 0.158 PC2W-75 1 0.176 0.176 PC2WH-177 1 0.290 0.290 1.060 Total 4 Maximum 2.5 Amps 2.018 Totals Maximum 10 Amps 8.292 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 594 699 765 680 Actual Wire run Distance 550 450 425 550 Voltage Drop for 14 AWG wire 3.705 2.575 2.223 3.235 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 562 549 623 615 Actual Wire run Distance 425 425 425 500 Voltage Drop for 14 AWG wire 3.027 3.097 2.730 3.254 Voltage Drop = 2 ' Wire Run Distance * 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts and a minimum voltage at the end of line of 16 Volts. Standby Hours 60 Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 (Alarm Current 8.467 Alarm Current 5 Min 0.703 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 7.323 (Battery Size Supplied 18 A.H. I • Standby Battery Calculations Altronix AL1002ULADA #5 JCPenney Seattle, WA 98188 :::.'Standby:.::.:: Cuirerit:.: i'::A1ami:» i':::. Current :::- Part:Numtier:::;::::.:: 'bescnpsori:';:;'::::'.:'::':':':':'.':'::::Cluantity:,:::,::::'P6r.:00ce:;:;::Ai bevices:::Per Device ;::'AIIIJevi as;: AL1002UL-ADA-J ADA Power Booster 10Aac 24VDC 1 0.090 0.090 0.175 0.175 ................ ...... ... ::_:Auxiliary,devicesMazirrium 3Anips.>:!< i:! :: }iii. iY.:: "_ ': ::•::._..::...:: ' :_: 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits ...Alarm:.. ._... Current;_ ..:Cir. it ..;....:!! ::: iii: i' »:![�evrce >i: i>::>:! �l ........................ .... ... duantitl`:::�:�:!�:�:�:�:iii?:!�:•:�:�:�:�:�:�i}Per�pgvice:;.;All.pevices: Circuit 1A PC2W-30 5 0.107 0.535 SCW-30 3 0.094 0.282 SCW-75 1 0.158 0.158 0.000 0.975 Circuit 113 PC2W-30 1 0.107 0.107 PC2W-15 1 0.079 0.079 PC2W-75 1 0.176 0.176 SCW-30 4 0.094 0.376 SCW-15 2 0.066 0.132 .... • ....• .:::'...•............................................ 0.870 Total 1 Maximum 2.5 Amps 1.845 Circuit 2A PC2W-30 1 0.107 0.107 PC2W-75 1 0.176 0.176 PC2W-15 2 0.079 0.158 SCW-15 1 0.066 0.066 SCW-75 2 0.158 0.316 0.823 Circuit 2B PC2W-75 2 0.176 0.352 SCW-30 2 0.094 0.188 0.000 0.000 ...• .• .............. 0.540 Total 2 Maximum 2.5 Amps 1.363 Circuit 3A 0.000 0.000 0.000 0.000 .... .......:..• .....• .• ........................................................ .......... .............. ......... ........ ......... 0.000 Circuit 38 0.000 0.000 0.000 :........ '... .............. ............................... 0.000 Total 3 Maximum 2.5 Mips 0.000 Circuit 4A 0.000 0.000 0.000 0.000 0.000 Circuit 4B 0.000 0.000 0.000 0.000 Total 4 Maximum 2.5 Amps 0.000 Totals Maximum 10 Amps 3.208 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 668 792 Actual Wire run Distance 450 375 Voltage Drop for 14 AWG wire 2.694 1.895 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 749 1206 Actual Wire run Distance 400 400 Voltage Drop for 14 AWG wire 2.137 1.326 Voltage Drop = 2 * Wire Run Distance * 3.07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 3.383 Alarm Current 5 Min 0.281 Battery Size Required with 5 Min. Alarm Time and 20% Reserve 6.817 Battery Size Supplied 18 AH. I HYDRAULIC CALCULATIONS CROWN FIRE PROTECTION BOTHELL, WASHINGTON Job JC PENNY - SOUTHCENTER MALL - Page 1 Date 05/01/07 Job: JCPEN-R1 LOWER LEVEL - UNDER MEZZANINE SEE SH 14 FOR ROOF CALCULATIONS Authority having Jurisdiction_ _ NFPA Occupancy ORDINARY HAZARD GP 2 Density 0.20 gpm/sq.ft. Area of Application 2000 square feet Coverage per Sprinkler 60 SF MAX Number of Sprinklers Calculated: 56 heads System type_ Hose Wet 500.0 gpm Inside Hose Water Supply Demand _ _ _ _ 150.00 psi Static, 20.00 psi Residual _ 91.65 psi @ 1038.6 gpm @ B.O.R. 95.31 psi @ 1538.6 gpm @ Supply 147.49 psi available @ 1538.6 gpm Demand is below curve by 52.18 psi Sprinklers _ _ K=5.6 PROGRAM: 'HydroCalc' by Micro Space Systems www.MicroSpaceSystems.com @ 13000.0 gpm IN U. II O 5 to gII O 0 H ij 0 cu 0 Z 4i 0 0 0 -L O C.A.) O O 0 to 1n 3 II System demand = 95.31 psi with 1538.6 gpm flowing. 0▪ 1 0 0 CO 0 0 0 -n 0 CI m O C.11 0 CO N CO 0 0 j W U1 O 0 0 a 0 ▪ 0 AOHNHHHOHNEM I 0 OD -4 0 0 OD 0 co 0 0 0 0 NJ 0 C.,..) ▪ -N- . 0 cn 0 F - _ _ _ 4 I- Avii r r I- - r r r r r Omni iiUI gepeAV'aiem Page 3 CROWN FIRE PROTECTION Description of Fitting abbreviations Code Description T Tee E Ninety degree elbow VE Victaulic ninety degree elbow ALV Alarm valve: Grinnell F200, F2001, F20 BV Butterfly valve GV Gate valve UE Underground ASCA ninety degree elbow UT1 Underground ASCA tee: flow in run, flow out bullhead only Description of Other abbreviations Code Description AO Arm -over BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction A.5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length Page 4 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - LOWER LEVEL - UNDER MEZZANINE SEE SH 14 FOR ROOF CALCULATIONS Raw data previous to any calculations No. Code Diam Length Kfacl Kfac2 Press Elev Hose HW Vel Fittings 1 AO1 1.080 1.0 5.6 7.00 0.00 0.0 120 321T 2 AO2 1.080 0.5 5.6 7.00 0.00 0.0 120 321T 3 AO3 1.080 1.5 5.6 7.00 0.00 0.0 120 321E,1T 4 AO4 1.080 6.0 5.6 7.00 0.00 0.0 120 321T 5 BL1 1.080 6.0 5.6 7.00 0.00 0.0 120 32 6 BL1 1.080 5.0 5.6 7.00 0.00 0.0 120 321T 7 BL2 1.080 8.0 5.6 7.00 0.00 0.0 120 32 8 BL2 1.408 8.0 5.6 7.00 0.00 0.0 120 32 9 BL2 1.408 8.0 5.6 7.00 0.00 0.0 120 32 10 BL2 1.639 7.0 5.6 7.00 0.00 0.0 120 321T 11 BL3 1.080 9.0 5.6 7.00 0.00 0.0 120 321E 12 BL3 1.408 8.0 5.6 7.00 0.00 0.0 120 32 13 BL3 1.408 8.0 5.6 7.00 0.00 0.0 120 32 14 BL3 1.639 7.0 5.6 7.00 0.00 0.0 120 321T 15 BL4 1.080 8.0 5.6 7.00 0.00 0.0 120 32 16 BL4 1.408 8.0 5.6 7.00 0.00 0.0 120 32 17 BL4 1.408 8.0 5.6 7.00 0.00 0.0 120 32 18 BL4 1.639 3.5 5.6 7.00 0.00 0.0 120 321T 19 BL5 1.080 0.5 5.6 7.00 0.00 0.0 120 32 20 BL5 1.408 7.5 AO4 7.00 0.00 0.0 120 32 21 BL5 1.408 8.0 5.6 7.00 0.00 0.0 120 32 22 BL5 1.639 1.5 5.6 7.00 0.00 0.0 120 32 23 BL5 1.639 6.5 AO4 7.00 0.00 0.0 120 32 24 BL5 2.104 0.5 5.6 7.00 0.00 0.0 120 321T 25 BL6 1.080 8.0 5.6 7.00 0.00 0.0 120 32 26 BL6 1.408 8.0 5.6 7.00 0.00 0.0 120 32 27 BL6 1.408 8.0 5.6 7.00 0.00 0.0 120 32 28 BL6 1.639 4.5 5.6 7.00 0.00 0.0 120 321T 32 CM1 2.203 5.0 BL1 A01 0.00 0.00 0.0 120 32 33 CM1 2.203 5.0 BL1 0.00 0.00 0.0 120 32 34 CM1 2.203 5.0 BL1 A01 0.00 0.00 0.0 120 32 35 CM1 2.203 5.0 BL1 0.00 0.00 0.0 120 32 36 CM1 2.203 5.0 BL1 0.00 0.00 0.0 120 32 37 CM1 2.203 5.0 BL1 AO1 0.00 0.00 0.0 120 32 38 CM1 2.203 0.5 BL1 0.00 0.00 0.0 120 32 39 CM2 3.314 5.0 BL2 AO3 0.00 0.00 0.0 120 32 40 CM2 3.314 5.0 BL3 BL5 0.00 0.00 0.0 120 32 41 CM2 3.314 5.0 BL4 BL6 0.00 0.00 0.0 120 32 42 CM2 3.314 1.0 AO2 0.00 0.00 0.0 120 321T 43 CM3 3.314 4.5 CM1 CM2 0.00 0.00 0.0 120 32 Page 5 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - LOWER LEVEL - UNDER MEZZANINE SEE SH 14 FOR ROOF CALCULATIONS Raw data previous to any calculations No. Code Diam Length Kfacl Kfac2 Press Elev Hose HW Vel Fittings 44 CM3 3.314 6.0 BL1 0.00 0.00 0.0 120 32 45 CM3 3.314 6.0 BL1 AO1 0.00 0.00 0.0 120 32 46 CM3 3.314 5.0 BL1 0.00 0.00 0.0 120 32 47 CM3 3.314 5.0 BL1 AO1 0.00 0.00 0.0 120 32 48 CM3 3.314 5.0 BL1 0.00 0.00 0.0 120 32 49 CM3 3.314 13.5 BL1 A01 0.00 0.00 0.0 120 321T 50 BU 4.310 13.0 CM3 0.00 0.00 0.0 120 323VE,1BV 80 BU 4.260 22.0 0.00 0.00 0.0 120 322VE,1T,1BV 81 BU 6.357 60.0 0.00 0.00 0.0 120 322VE 82 RI 8.249 16.0 BU 0.00 10.00 0.0 120 321ALV,2VE 83 UG 8.270 200.0 RI 0.00 0.00 500.0 140 324UE,1UT1,1GV Page 6 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - LOWER LEVEL - UNDER MEZZANINE SEE SH 14 FOR ROOF CALCULATIONS Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Arm -over 1 C = 120 A 1.0 PT 7.00 1 14.8=5.60(7.00)A.5 F 5.8 PE 0.00 1 14.8 1.08 1T T 6.8 0.06483 PF 0.44 5.19 PT 7.44 32 B1 Jct K -factor for arm -over 1 = 14.8/(7.44)A.5 = 5.43 at Hyd Ref Pts 32 34 37 45 47 49 Arm -over 2 C = 120 A 0.5 PT 7.00 2 14.8=5.60(7.00)A.5 F 5.8 PE 0.00 2 14.8 1.08 1T T 6.3 0.06483 PF 0.41 5.19 PT 7.41 42 B1 Jct K -factor for arm -over 2 = 14.8/(7.41)A.5 = 5.44 Arm -over 3 C = 120 A 1.5 PT 7.00 3 14.8=5.60(7.00)".5 F 8.1 PE 0.00 3 14.8 1.08 1E 1T T 9.6 0.06483 PF 0.62 5.19 PT 7.62 39 B1 Jct K -factor for arm -over 3 = 14.8/(7.62)A.5 = 5.36 Arm -over 4 C = 120 A 6.0 PT 7.00 4 14.8=5.60(7.00)A.5 F 5.8 PE 0.00 4 14.8 1.08 iT T 11.8 0.06483 PF 0.76 5.19 PT 7.76 20 131 Jct K -factor for arm -over 4 = 14.8/(7.76)x.5 = 5.31 at Hyd Ref Pts 20 23 Branchline No. 1 C = 120 A 6.0 PT 7.00 5 End head 14.8=5.60(7.00)A.5 F 0.0 PE 0.00 5 14.8 1.08 T 6.0 0.06483 PF 0.39 5.19 A 5.0 PT 7.39 6 15.2=5.60(7.39)A.5 F 5.8 PE 0.00 6 30.0 1.08 1T T 10.8 0.23965 PF 2.58 10.52 PT 9.97 32 Cross main Jct K -factor for branchline no. 1 = 30.0/(9.97)''.5 = 9.50 at Hyd Ref Pts 32 33 34 35 36 37 38 44 45 46 47 48 49 Page 7 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - LOWER LEVEL - UNDER MEZZANINE SEE SH 14 FOR ROOF CALCULATIONS Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 2 C = 120 A 8.0 PT 7.00 7 End head 14.8=5.60(7.00)A.5 F 0.0 PE 0.00 7 14.8 1.08 T 8.0 0.06483 PF 0.52 5.19 A 8.0 PT 7.52 8 15.4=5.60(7.52)'.5 F 0.0 PE 0.00 8 30.2 1.41 T 8.0 0.06641 PF 0.53 6.22 A 8.0 PT 8.05 9 15.9=5.60(8.05)A.5 F 0.0 PE 0.00 9 46.1 1.41 T 8.0 0.14525 PF 1.16 9.49 A 7.0 PT 9.21 10 17.0=5.60(9.21)A.5 F 8.7 PE 0.00 10 63.1 1.64 1T T 15.7 0.12392 PF 1.95 9.59 PT 11.16 39 Cross main Jct K -factor for branchline no. 2 = 63.1/(11.16)A.5 = 18.89 Branchline No. 3 C = 120 A 9.0 PT 7.00 11 End head 14.8=5.60(7.00)A.5 F 2.3 PE 0.00 11 14.8 1.08 1E T 11.3 0.06483 PF 0.73 5.19 A 8.0 PT 7.73 12 15.6=5.60(7.73)A.5 F 0.0 PE 0.00 12 30.4 1.41 T 8.0 0.06729 PF 0.54 6.26 A 8.0 PT 8.27 13 16.1=5.60(8.27)A.5 F 0.0 PE 0.00 13 46.5 1.41 T 8.0 0.14779 PF 1.18 9.58 A 7.0 PT 9.45 14 17.2=5.60(9.45)A.5 F 8.7 PE 0.00 14 63.7 1.64 1T T 15.7 0.12631 PF 1.99 9.69 PT 11.44 40 Cross main Jct K -factor for branchline no. 3 = 63.7/(11.44)A.5 = 18.83 Page 8 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - LOWER LEVEL - UNDER MEZZANINE SEE SH 14 FOR ROOF CALCULATIONS Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 4 C = 120 A 8.0 PT 7.00 15 End head 14.8=5.60(7.00)A.5 F 0.0 PE 0.00 15 14.8 1.08 T 8.0 0.06483 PF 0.52 5.19 A 8.0 PT 7.52 16 15.4=5.60(7.52)''.5 F 0.0 PE 0.00 16 30.2 1.41 T 8.0 0.06641 PF 0.53 6.22 A 8.0 PT 8.05 17 15.9=5.60(8.05)".5 F 0.0 PE 0.00 17 46.1 1.41 T 8.0 0.14525 PF 1.16 9.49 A 3.5 PT 9.21 18 17.0=5.60(9.21)A.5 F 8.7 PE 0.00 18 63.1 1.64 1T T 12.2 0.12392 PF 1.52 9.59 PT 10.73 41 Cross main Jct K -factor for branchline no. 4 = 63.1/(10.73)'.5 = 19.27 Branchline No. 5 (Beginning pressure increased due to Hyd Ref Pt 20) C = 120 A 0.5 PT 7.73 19 End head 15.6=5.60(7.73)A.5 F 0.0 PE 0.00 19 15.6 1.08 T 0.5 0.07103 PF 0.04 5.45 A 7.5 PT 7.76 20 AO4 14.8=5.31(7.76)A.5 F 0.0 PE 0.00 20 30.4 1.41 T 7.5 0.06721 PF 0.50 6.26 A 8.0 PT 8.27 21 16.1=5.60(8.27)A.5 F 0.0 PE 0.00 21 46.5 1.41 T 8.0 0.14765 PF 1.18 9.58 A 1.5 PT 9.45 22 17.2=5.60(9.45)A.5 F 0.0 PE 0.00 22 63.7 1.64 T 1.5 0.12621 PF 0.19 9.68 A 6.5 PT 9.64 23 AO4 16.5=5.31(9.64)''.5 F 0.0 PE 0.00 23 80.2 1.64 T 6.5 0.19325 PF 1.26 12.19 A 0.5 PT 10.89 24 18.5=5.60(10.89)''.5 F 10.9 PE 0.00 24 98.7 2.10 1T T 11.4 0.08405 PF 0.96 9.10 PT 11.85 40 Cross main Jct K -factor for branchline no. 5 = 98.7/(11.85)A.5 = 28.67 Page 9 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - LOWER LEVEL - UNDER MEZZANINE SEE SH 14 FOR ROOF CALCULATIONS Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 6 C = 120 A 8.0 PT 7.00 25 End head 14.8=5.60(7.00)'.5 F 0.0 PE 0.00 25 14.8 1.08 T 8.0 0.06483 PF 0.52 5.19 A 8.0 PT 7.52 26 15.4=5.60(7.52)'.5 F 0.0 PE 0.00 26 30.2 1.41 T 8.0 0.06641 PF 0.53 6.22 A 8.0 PT 8.05 27 15.9=5.60(8.05)".5 F 0.0 PE 0.00 27 46.1 1.41 T 8.0 0.14525 PF 1.16 9.49 A 4.5 PT 9.21 28 17.0=5.60(9.21)'.5 F 8.7 PE 0.00 28 63.1 1.64 1T T 13.2 0.12392 PF 1.64 9.59 PT 10.85 41 Cross main Jct K -factor for branchline no. 6 = 63.1/(10.85)'.5 = 19.16 Page 10 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - LOWER LEVEL - UNDER MEZZANINE SEE SH 14 FOR ROOF CALCULATIONS Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 1 C = 120 K=14.93=9.50+5.43 A 5.0 PT 9.97 32 BL1 + AO1 47.1=14.93(9.97)A.5 F 0.0 PE 0.00 32 47.1 2.20 T 5.0 0.01713 PF 0.09 3.97 A 5.0 PT 10.05 33 BL1 30.1=9.50(10.05)A.5 F 0.0 PE 0.00 33 77.3 2.20 T 5.0 0.04275 PF 0.21 6.50 K=14.93=9.50+5.43 A 5.0 PT 10.27 34 BL1 + AO1 47.8=14.93(10.27)".5 F 0.0 PE 0.00 34 125.1 2.20 T 5.0 0.10425 PF 0.52 10.53 A 5.0 PT 10.79 35 BL1 31.2=9.50(10.79)A.5 F 0.0 PE 0.00 35 156.3 2.20 T 5.0 0.15741 PF 0.79 13.16 A 5.0 PT 11.58 36 BL1 32.3=9.50(11.58)A.5 F 0.0 PE 0.00 36 188.6 2.20 T 5.0 0.22289 PF 1.11 15.88 K=14.93=9.50+5.43 A 5.0 PT 12.69 37 BL1 + AOl 53.2=14.93(12.69)A.5 F 0.0 PE 0.00 37 241.8 2.20 T 5.0 0.35289 PF 1.76 20.35 A 0.5 PT 14.45 38 BL1 36.1=9.50(14.45)A.5 F 0.0 PE 0.00 38 278.0 2.20 T 0.5 0.45656 PF 0.23 23.40 PT 14.68 43 Cross main Jct K -factor for Cross main 1 = 278.0/(14.68)A.5 = 72.55 Page 11 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - LOWER LEVEL - UNDER MEZZANINE SEE SH 14 FOR ROOF CALCULATIONS Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 2 (Beginning pressure increased due to Hyd Ref Pt 40) C = 120 K=24.25=18.89+5.36 A 5.0 PT 11.82 39 BL2 + A03 83.4=24.25(11.82)'.5 F 0.0 PE 0.00 39 83.4 3.31 T 5.0 0.00674 PF 0.03 3.10 K=47.50=18.83+28.67 A 5.0 PT 11.86 40 BL3 + BL5 163.6=47.50(11.86)A.5 F 0.0 PE 0.00 40 246.9 3.31 T 5.0 0.05021 PF 0.25 9.18 K=38.42=19.26+19.16 A 5.0 PT 12.11 41 BL4 + BL6 133.7=38.42(12.11)A.5 F 0.0 PE 0.00 41 380.6 3.31 T 5.0 0.11180 PF 0.56 14.16 A 1.0 PT 12.67 42 A02 19.4=5.44(12.67)'.5 F 21.8 PE 0.00 42 400.0 3.31 1T T 22.8 0.12255 PF 2.80 14.88 PT 15.46 43 Cross main Jct K -factor for Cross main 2 = 400.0/(15.46)".5 = 101.72 Page 12 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - LOWER LEVEL - UNDER MEZZANINE SEE SH 14 FOR ROOF CALCULATIONS Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 3 C = 120 K=174.27=72.55+101.72 A 4.5 PT 15.47 43 CM 1 + CM 2 685.3=174.27(15.47)".5 F 0.0 PE 0.00 43 685.3 3.31 T 4.5 0.33184 PF 1.49 25.49 A 6.0 PT 16.96 44 BL1 39.1=9.50(16.96)".5 F 0.0 PE 0.00 44 724.5 3.31 T 6.0 0.36774 PF 2.21 26.95 K=14.93=9.50+5.43 A 6.0 PT 19.16 45 BL1 + A01 65.4=14.93(19.16)".5 F 0.0 PE 0.00 45 789.8 3.31 T 6.0 0.43146 PF 2.59 29.38 A 5.0 PT 21.75 46 BL1 44.3=9.50(21.75)".5 F 0.0 PE 0.00 46 834.1 3.31 T 5.0 0.47731 PF 2.39 31.03 K=14.93=9.50+5.43 A 5.0 PT 24.14 47 BL1 + AO1 73.4=14.93(24.14)".5 F 0.0 PE 0.00 47 907.5 3.31 T 5.0 0.55785 PF 2.79 33.75 A 5.0 PT 26.93 48 BL1 49.3=9.50(26 93)".5 F 0.0 PE 0.00 48 956.8 3.31 T 5.0 0.61522 PF 3.08 35.59 K=14.93=9.50+5.43 A 13.5 PT 30.01 49 BL1 + AO1 81.8=14.93(30.01)".5 F 21.8 PE 0.00 49 1038.6 3.31 iT T 35.3 0.71602 PF 25.30 38.63 PT 55.31 50 Bulk Jct K -factor for Cross main 3 = 1038.6/(55.31)".5 = 139.65 Page 13 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - LOWER LEVEL - UNDER MEZZANINE SEE SH 14 FOR ROOF CALCULATIONS Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Bulk C = 120 ___= A 13.0 PT 55.31 50 CM 3 1038.6=139.65(55.31)'.5 F 45.2 PE 0.00 50 1038.6 4.31 3VE 1BV T 58.2 0.19915 PF 11.58 22.84 A 22.0 PT 66.89 80 F 60.0 PE 0.00 80 1038.6 4.26 2VE 1T T 82.0 0.21080 PF 17.29 23.38 1BV A 60.0 PT 84.18 81 F 25.2 PE 0.00 81 1038.6 6.36 2VE T 85.2 0.03001 PF 2.56 10.50 PT 86.74 82 Top of Riser Riser C = 120 A 16.0 PT 86.74 82 Top of Riser F 53.4 PE 4.33 (EL= 10.00 ft) 82 1038.6 8.25 1ALV 2VE T 69.4 0.00844 PF 0.59 6.24 PT 91.65 83 B.O.R. Under ground A 200.0 PT 91.65 83 500.0 gpm = Hose F 82.0 PE 0.00 83 1538.6 8.27 4UE lUT1 T 282.0 0.01296 PF 3.66 1GV PT 95.31 84 9.19 C = 140 B.O.R. Supply Jct Available flow at 95.31 psi is 8141.1 gpm which is 6602.5 gpm from curve. Supply pressure available with 1538.6 gpm flowing is 147.49 psi, thus system requirement is 52.18 psi below supply curve. (35.4%) Page 14 HYDRAULIC CALCULATIONS CROWN FIRE PROTECTION BOTHELL, WASHINGTON Date 04/04/07 Job: JCPEN-R2 Job_ _ JC PENNY - SOUTHCENTER MALL - ROOF LEVEL Authority having Jurisdiction_ _ NFPA Occupancy ORDINARY HAZARD Density 0.30 gpm/sq.ft. Area of Application 3000 square feet Coverage per Sprinkler 100 SF MAX System type_ _ Wet Hose 500.0 gpm Inside Hose Water Supply _ 150.00 psi Static, 20.00 psi Residual @ 13000.0 gpm Demand_ _ _ _ 75.19 psi @ 1299.7 gpm @ B.O.R. 80.07 psi @ 1799.7 gpm @ Supply 146.65 psi available @ 1799.7 gpm Demand is below curve by 66.58 psi Sprinklers _ _ k=11.2 PROGRAM: 'HydroCalc' by Micro Space Systems www.MicroSpaceSystems.com ..L NJ LJ d d ▪ CD CD CO CD C) NJ - a 3 ■ System demand = 80.07 psi with 1799.7 gpm flowing. NJ CD O O 0.) (31 O CD 01 O O 1 emn3 iimpgepeAv ialem Page 16 CROWN FIRE PROTECTION Description of Fitting abbreviations Code Description T Tee E Ninety degree elbow VE Victaulic ninety degree elbow ALV Alarm valve: Grinnell F200, F2001, F20 BV Butterfly valve GV Gate valve UE Underground ASCA ninety degree elbow UT1 Underground ASCA tee: flow in run, flow out bullhead only Description of Other abbreviations Code Description BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction ".5 Raised to the power of 5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length Page 17 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - ROOF LEVEL Raw data previous to any calculations No. Code Diam Length Kfacl Kfac2 Press Elev Hose HW Vel Fittings 60 BL10 1.408 11.5 11.2 7.00 0.00 0.0 120 32 61 BL10 1.408 11.5 11.2 0.00 0.00 0.0 120 32 62 BL10 1.639 4.0 11.2 0.00 2.00 0.0 120 321T,1E 63 PC10 0.000 0.0 BL10 1/3 0.00 0.00 0.0 120 32 64 CM10 4.310 8.0 BL10 0.00 0.00 0.0 120 32 65 CM10 4.310 8.0 BL10 0.00 0.00 0.0 120 32 66 CM10 4.310 8.0 BL10 0.00 0.00 0.0 120 32 67 CM10 4.310 8.0 BL10 0.00 0.00 0.0 120 32 68 CM10 4.310 8.0 BL10 0.00 0.00 0.0 120 32 69 CM10 4.310 8.0 BL10 0.00 0.00 0.0 120 32 70 CM10 4.310 8.0 BL10 0.00 0.00 0.0 120 32 71 CM10 4.310 8.0 BL10 0.00 0.00 0.0 120 32 72 CM10 4.310 8.0 BL10 0.00 0.00 0.0 120 32 73 CM10 4.310 5.0 BL10 0.00 0.00 0.0 120 321T 74 CM11 4.310 8.0 PC10 0.00 0.00 0.0 120 32 75 CM11 4.310 8.0 BL10 0.00 0.00 0.0 120 32 76 CM11 4.310 3.0 BL10 0.00 0.00 0.0 120 32 78 BU 4.310 12.0 CM10 CM11 0.00 0.00 0.0 120 322VE 80 EU 4.260 22.0 0.00 9.00 0.0 120 322VE,1T,1BV 81 BU 6.357 60.0 0.00 0.00 0.0 120 322VE 82 RI 8.249 16.0 BU 0.00 10.00 0.0 120 321ALV,2VE 83 UG 8.270 200.0 RI 0.00 0.00 500.0 140 324UE,1UT1,1GV Page 18 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - ROOF LEVEL Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 10 C = 120 A 11.5 PT 7.00 60 End head 29.6=11.20(7.00)A.5 F 0.0 PE 0.00 60 29.6 1.41 T 11.5 0.06423 PF 0.74 6.11 A 11.5 PT 7.74 61 31.2=11.20(7.74)".5 F 0.0 PE 0.00 61 60.8 1.41 T 11.5 0.24268 PF 2.79 12.53 A 4.0 PT 10.53 62 36.4=11.20(10.53)A.5 F 13.1 PE 0.87 (EL= 2.00 ft) 62 97.1 1.64 1T lE T 17.1 0.27560 PF 4.71 14.77 PT 16.11 64 Cross main Jct K -factor for branchline no. 10 = 97.1/(16.11)".5 = 24.20 at Hyd Ref Pts 64 65 66 67 68 69 70 71 72 73 75 76 74 Page 19 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - ROOF LEVEL Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 10 C = 120 A 8.0 PT 16.11 64 BL10 97.1=24.20(16.11)".5 F 0.0 PE 0.00 64 97.1 4.31 T 8.0 0.00248 PF 0.02 2.14 A 8.0 PT 16.12 65 BL10 97.2=24.20(16.12)A.5 F 0.0 PE 0.00 65 194.3 4.31 T 8.0 0.00896 PF 0.07 4.27 A 8.0 PT 16.20 66 BL10 97.4=24.20(16.20)A.5 F 0.0 PE 0.00 66 291.6 4.31 T 8.0 0.01900 PF 0.15 6.41 A 8.0 PT 16.35 67 BL10 97.8=24.20(16.35)A.5 F 0.0 PE 0.00 67 389.5 4.31 T 8.0 0.03244 PF 0.26 8.56 A 8.0 PT 16.61 68 BL10 98.6=24.20(16.61)A.5 F 0.0 PE 0.00 68 488.1 4.31 T 8.0 0.04925 PF 0.39 10.73 A 8.0 PT 17.00 69 BL10 99.8=24.20(17.00)A.5 F 0.0 PE 0.00 69 587.8 4.31 T 8.0 0.06948 PF 0.56 12.93 A 8.0 PT 17.56 70 BL10 101.4=24.20(17.56)A.5 F 0.0 PE 0.00 70 689.2 4.31 T 8.0 0.09326 PF 0.75 15.16 A 8.0 PT 18.30 71 BL10 103.5=24.20(18.30)A.5 F 0.0 PE 0.00 71 792.7 4.31 T 8.0 0.12082 PF 0.97 17.43 A 8.0 PT 19.27 72 BL10 106.2=24.20(19.27)".5 F 0.0 PE 0.00 72 899.0 4.31 T 8.0 0.15246 PF 1.22 19.77 A 5.0 PT 20.49 73 BL10 109.5=24.20(20.49)A.5 F 27.9 PE 0.00 73 1008.5 4.31 1T T 32.9 0.18859 PF 6.20 22.18 PT 26.69 78 Bulk Jct K -factor for Cross main 10 = l008.5/(26.69)A.5 = 195.21 Page 20 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - ROOF LEVEL Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 11 C = 120 A 8.0 PT 16.11 74 1/3*BL10 32.4=8.07(16.11)A.5 F 0.0 PE 0.00 74 32.4 4.31 T 8.0 0.00033 PF 0.00 0.71 A 8.0 PT 16.11 75 BL10 97.1=24.20(16.11)A.5 F 0.0 PE 0.00 75 129.5 4.31 T 8.0 0.00423 PF 0.03 2.85 A 3.0 PT 16.14 76 BL10 97.2=24.20(16.14)A.5 F 0.0 PE 0.00 76 226.7 4.31 T 3.0 0.01192 PF 0.04 4.98 PT 16.18 78 Bulk Jct K -factor for Cross main 11 = 226.7/(16.18)x.5 = 56.36 Page 21 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations JC PENNY - SOUTHCENTER MALL - ROOF LEVEL Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Bulk C = 120 K=251.58=195.22+56.36 A 12.0 PT 26.69 78 CM 10 + CM 11 1299.7=251.58(26.69)A.5 F 19.0 PE 0.00 78 1299.7 4.31 2VE T 31.0 0.30154 PF 9.33 28.58 A 22.0 PT 36.02 80 F 60.0 PE 3.90 (EL= 9.00 ft) 80 1299.7 4.26 2VE iT T 82.0 0.31917 PF 26.18 29.26 1BV A 60.0 PT 66.10 81 F 25.2 PE 0.00 81 1299.7 6.36 2VE T 85.2 0.04544 PF 3.87 13.14 PT 69.97 82 Top of Riser Riser C = 120 A 16.0 PT 69.97 82 Top of Riser F 53.4 PE 4.33 (EL= 10.00 ft) 82 1299.7 8.25 1ALV 2VE T 69.4 0.01278 PF 0.89 7.80 PT 75.19 83 B.O.R. Under ground A 200.0 PT 75.19 83 500.0 gpm = Hose F 82.0 PE 0.00 83 1799.7 8.27 4UE lUT1 T 282.0 0.01732 PF 4.89 10.75 1GV PT 80.07 84 C = 140 B.O.R. Supply Jct Available flow at 80.07 psi is 9297.9 gpm which is 7498.2 gpm from curve. Supply pressure available with 1799.7 gpm flowing is 146.65 psi, thus system requirement is 66.58 psi below supply curve. (45.4%) .tyc® Fire & Security ADT Scope Of Work Project Name: JcPenny Shoe Storage Westfield Shoppingtown SouthCenter Mall Tukwila, WA 98188 For Fire Alarm System Installation and Monitoring By: ADT Security Services 11824 North Creek Parkway N., Suite 105 Bothell, WA 98011 Contact: Alfred Evans Telephone: 206-383-4722 Quantity Model Description ADT Security Services, Inc. 11824 Northcreek Parkway North Suite #105 Bothell, WA 98011 Tele: 425 402 3351 FILE 1 1 1 D7024 (By Others) (By Others) Scope of Work: Existing Bosch Fire Alarm Control Panel Connection to Waterflow Switch Connection to Gate Valve The Waterflow and Gate Valve located in the new JcPenny Shoe Storage area will to be monitored by the Existing JcPenny Fire Alarm Control Panel (a Bosch D7024). All other devices are a '$. g,.apd to_rem in CCEPTED Without Comments 0 As Noted In Red Per The Attached Letter These plans have been revin,'ed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance it.. ?_,t',ect to errors and omissions which do not aLthurze violations of adopted stenoaraa and T : r e_pccnsibility for the adequacy of Lie ‘.f,"1 the designer. Additions, ci:� :`,` or 4 these drawings atter this date yr- 4 .Jr _ e and will require a resubmita c` , e r ' S r1rjs for subsequent approval. Final accept_'.-cee ;c = ^t t. Fell test and inspection by The Tukwila Fire Bureau. Date: S —07 By: /dv- s-iJ NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing, l tiftWILA FIRE DEPARTMENT,, Please call: 575.44.02 and give this job No....07-f -(D-0 1;d exact address for shut. ouwrl ur rest:ration allot -01/4 two Fire & Security Battery Calculation Worksheet (all currents stated in mA) 5/8/2007 PROJECT: JcPenny Shoe Storage, SouthCenter Mall FACP Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices D7024 Fire Alarm Control Panel 1 200 380 200 380 0 0 5 0 0 0 0 0 380 0 0 0 0 0 0.03 0 0 0 0 0 1.45 0 0 0 Total System Current 0 0 200 380 Smoke Detectors / Auxiliary Devices 0 N/A 78 0 0 5 0 N/A 155 0 0 380 0 N/A 148 0 0 0.03 0 N/A 123 0 0 1.45 0 16 16 0 0 0 N/A 0.41 0 0 0 0 0 0 0 Device Totals 0 0 0 Notification Appliances (list all) 0 N/A 78 N/A 0 5 0 N/A 155 N/A 0 380 0 N/A 148 N/A 0 0.03 0 N/A 123 N/A 0 1.45 0 16 16 N/A 0 0 N/A 0.41 N/A 0 0 N/A 88 N/A 0 Notification Appliance Totals 0 N/A 0 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 200 Total System Alarm mA 380 Total System Standby A/H 4.80 Total System Alarm A/H 0.03 Min. A/H Battery 4.83 ADD 15% FOR BATTERY DEPLETION 1.45 Required A/H Battery 1 6.28 A/H BATTERY PROVIDED FOR SYSTEM 14 1 D7024 24V Fire Control/Communicator Specifications Features Conventional Features • Four conventional zone (expandable to eight) Fire Alarm Control Panel (FACP) • Built-in Digital Alarm Communicator Transmitter (DACT) • 4 Programmable authority levels • Each detector zone supports up to 20 two -wire smoke detectors • Up to 18 programmable relay outputs • 32 character backlit LCD display • Supports up to four D7033 Fire System Controllers and eight D7030X Series LED Annunciators • Two Notification Appliance Circuits (NAC) on board • Internal 24VDC, 4 amp NAC power supply • Programmable through front panel interface or remote D7033 Fire System Controller • 99 event history buffer • Option Bus provides serial data interface for fire alarm accessories • UL Listed for fire applications • Compatible with RAM IV • Wheelock"' Signal Sync Multiplex Features (07039) • Expandable to 255 addresses using multiplex technology • Relay outputs expandable to 58 • 499 event history buffer • PING available for up to 100 system users • Compatible with RAM IV Description Conventional 07024 FACP The Radionics D7024 is a fully integrated FACP that provides four zones and is capable of supporting both two -wire and four -wire detectors. Each zone can support up to 20 two -wire detectors, or any number of four -wire detectors (depending on available power). Two Notification Appliance Circuits (NAC) provides up to 4 amps of 24 -volt power to operate horns, strobes, bells, and other notification appliances, Each NAC can be programmed to provide the Wheelock"" Synchronized Output. System control can be accessed through a built-in user interface in the panel, or through the remote D7033 Fire System Controllers connected to the system. D7024 Fire ControUCommunicator A viewing port in the keyed panel enclosure door leaves the system status LEDs and LCD display visible while maintaining system control key security. Unlocking the enclosure door provides access to the system keys for silencing alarm and trouble conditions, zone bypassing, detector resetting, testing, and other fire functions as well as programming. These functions are also available on all D7033 Controllers connected to the system. All system controllers provide custom text annunciation on a 32 character, backlit, two-line LCD display. All system controllers also have built-in sounders. Back- light intensity and sounder volume am programmable. 16 Personal Identification Numbers (PiN) are available for access to system control. Each number can be assigned an authority level to limit system control functions that may be accessed. The system stores events in a 99 -event memory log. The D7024 Communicator reports to two telephone numbers with full single, double, and backup reporting and communicates in BFSK, SIA, Contact ID, Modem II1a2 and 4/2 and 3/1 Tone Bursts. The D7024 enclosure has space for additional accessory modules and two 01218 12V, 17 Ah batteries or two D126 12V, 7 Ah batteries. Multiplex Technology (07039) The D7024 conventional system features can be enhanced, when running version 2.02 or higher firmware with the addition of a D7039 Multiplex Expansion Modulo. The D7039 expands the base system up to 255 addressable points, increases the number of relay outputs to 58 and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also allows for up to 100 system users (an addition of 84 PING from the base system). ri1:1 radionics A member of the Bosch Group D7024 Application The D7024 can be used in commercial and public budding applications such as schools, universities, manufacturing plants and health care facilities. It is listed by UL for Central Station, Local, Auxiliary and Remote Station Systems. Installation The D7024 enclosure and the Control/Communicator are shipped together. All mounting hardware necessary for mounting the Control/Communicator in the enclosure is included. The control panel must be installed in accordance to the National Electrical Code (NFPA 70), the National Fire Alarm Code (NFPA 72) and the Authority Having Jurisdiction. Specifications Power Input 120 V, 60 Hz, 1.5 Amax (20 A fused supply circuit). NAC 24 VDC nominal, 4 A; circuit rating: 2.5 A. Auxiliary 24 VDC nominal. unfiltered, 1.0 A. Smoke 24 VDC nominal. filtered, 1.0 A. Option Bus 12 VDC nominal, 500 mA. nest Of ' c, (tiNACa NAC Outputs 2 on -board NAC Wring Standard Class B, Style Y operation. Use 07015 for Class A, Style Z operation. Ya On -board Relays Two Form "C" relays rated at 5 A, 28VDC each. Off -board Relays Up to two 07035 Octal Relay Modules providing eight Form'C" relay outputs each. Contacts rated at 5 A� 28 VDC. Onboard Convefttiortiti Points Number of 2- YWre Circuits Four circuits, expandable to eight usIng a 07034 Four Point Expander Modulo. Circuit Type Class B, Style B (use a 07014 for Class A, Style 0 operation), EOL Resistor 2.21K ohms (P/N: 25899, UL listed). Supervisory Current 8-20 mA Required Alarm Current 25 mA Max. Short Circuit Currant 44 rM Max. Line Resistance 150 ohms Circuit Voltage Range 20.4 — 28.2 VDC Max. Detectors per Point 20 detectors (2 -wire) Total Detector Standby Current 3 rnA max. Response Time Fast A 0.5 sec; progrommoble from 1 to 89 seconds. Storsos and Tklmwt►*ws Temperature +32' to 120'F (0' to +49'C) j� Off4bcerd Addressable t+xpt Points (w,+ 07030 Multiplex Module) Number of Signaling Line Circuits (SLC) Two Class B, Style 4 SLC's (can be combined into one Class A, Style 8 circuit) E9ci Pin ntsIArli Vltidtln 15 In. (38.1 cm) Height 20,8 In. (52.7 cm) Depth 4.3 in. (10.8 cm) Keypad $Anptaraiators 07033 Keypads Four (max.) D7030X Series Annunciators Eight (max.) Wre Typo 818 AW3 (min.); four -conductor F.P.L. Option Bus Wiring 4,000 ft. (1,219.2 m) max. Listings and Approvals • Underwriters Laboratories UL 884 • CSFM • NYC -MEA 12-92-E Vol. VII Ordering Information Modal mon 0128 (2) 12 V, 7 Ah Battery (8 in. x 2.8 in. x 3.94 In.) 0185 Reverse Polarity Signaling Module D275 End Of Lira Power Supervision Module D1218 (2) 12 V, 17 Ah Battery (7.13 In. x 3 In. x 8.63 In.) 07014 Class A Zone Convertor 07015 Class A NAC Converter D7024 24VDC Fire ControUCormrunicator D7030X Eight Point LED Annunicator D7030X-S2 Eight Point LED Annunicator (2 Yellow, 6 Red) D7030X-S8 Eight Point LED Annunicator (8 Yellow) 07031 Silence Reset Module 07032 8 Zone LED Annunciator Expander 07033 LCD Fire System Controller Keypad D7034 Four Point Expander 07035/B Octal Relay Module/Box 07038 LCD Annunicator (Silence and Reset Kay enabled) D7038 Remote NAC Power Supply 07039 Multiplex Expansion Modulo 07042/B Multiplex Eight -Input Remote Module 07048/8 Multiplex Octal Driver 07050 Photoelectric Smoke Detector cur Chamber Check Dirty Chamber Sensing 07050TH Photoelectric Smoke Detector wr High Temperature Sensing & Chanter Check Dirty Chamber Sensing (07050-86 — 8 in. Base Required) 0343 Multiplex Duct Smoke Detector 2002 Radionics, a division of Detection Systems, Inc. PO Box 80012, Salinas, CA 93912-0012, USA Customer Service: (800) 538-6807 433348 Specifications 2/02 07024 Page 2 of 2 Owner Information: JCPenney 6501 Legacy drive Plano, TX (972) 431-1000 Real Estate Dept. Installing Contractor: Tyco Integrated Security 11824 No Creek Parkway Bothell, WA 98011 (206) 624-3103 Fire Alarm Designer: Tyco Integrated Security Dusty Jones, ET Fire Alarm Systems, Level III — NICET #120752 Expires October 1, 2013 120 West Park Dr. Birmingham, AL 35211 (205) 940-7337 Monitoring Center: Tyco Integrated Security 14200 Exposition Ave Aurora, CO 80012 Phone (303) 338-8200 UL Listing Number S994- 183 UUFX Fire Department Contact: Tukwilla Fire Prevention 444 Andover Park East Tukwilla, WA 98188 (206) 575-4404 Al Metzler 2d1 S V t1 e of The original fire alarm was upgraded by in mid 2008. It was upgraded to an addressable Firelite MS -9600 System. This FA system included: • Smoke detectors at select locations, as Alarm • Duct detectors on the Supply and Return of all HVAC units, as Supervisory • All Sprinkler water flow & pressure switches, as Alarm s AM Sprinkler tamper valves, as Supervisory • Complete occupant notification in all public areas. AM Horn/Strobes are Synchronized The scope of this project is to adjust this previously installed Fire Alarm System per the renovation changes that JC Penney is making to their store. All of the changes made shall be clouded and noted with a Revision triangle. The extent of the changes consists of adding, removing, and relocating Horn/Strobes to correct coverage. =Star denotes the ORIGINAL location of device that is to be Removed/Relocated. =Arrow .-points TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. 13- I- - /"-> and exact address for shut- down or restoragon approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior .to commencement of Acceptance Testing of any Fire Alarm and Detection Systems.. Failure of test will result in a Re -inspection Fee and termination of the N:• • r Q Without Comments As iNNoted in Red Letter O Per The Atttaci i d tt These plans have been reviewed by The Tukwila Fire Prevention Bureau for confon-nance with current City Standards. Accepzanu,i s subs cf to errors and omissions which do not authorize violations of adopted stldards and ordin !rkm The responsibility for the adequacy of de gr: totally wftl s the designer. Additions,E✓:': =fJot S or rovisions to these drawings after this ailil vole this Zcceptance and will require a resubmittal ui rovi°sed drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date:_" °LL �I ocation of the device Building Information: Occupancy Type: "M" Mercantile Building IS Sprinkled. Number of Stories: 3 Sq Footage: 236,000 1st f Ir: 78,000 2nd f Ir: 80,000 3rd f Ir: 78,000 Sheet Index: 1 = FA Cover Sheet 2 = FA Plan 1st Floor 3 = FA Plan 2nd Floor 4 = FA Plan 3rd Floor 5 = FA Riser Diagram 6 = FA Battery Calcs Fire Alarm Legend Symbol Qty Description Manufacture/Part Number Mounting Requirements 1 Fire Alarm Control Panel FireLite MS9600 W/DACT-UD Surface mounted enclosure provided Top 72' AFF conduit -to ceiling FCP 1 Fire Alarm Annunciator Alpha Keypad FireLite LCD -80F Single or double Gang, 4' square box 60' AFF conduit to ceiling FSA 6 Addressable Dual Monitor Module FireLite MDF300 4' square deep box MDF 13 Addressable Monitor Module FireLite MMF300, MMF301 4' square deep box lig ®P 6 Smoke Detector Photo Electric FireLite SD355 Single Gang, 3.5' Octagon or 4' Sq. Box in -the ceiling OR 0 Heat Detector R of R 135 deg or indicated Fire Lite H355R 3 1/4' Octagon box mounted in -the ceiling ® 0 Manual Pull Station FireLite BG-12LX Deep Single Gang Box 48' AFF -to Center, Conduit to ceiling 16 Addressable Control Module FireLite CRF -300 4' square deep box CRF ®25 D Duct Smoke Detector Photo Electric FireLite D350PL 1/2' Flex to 4' Square Box 25 Remote indicator Test/Reset FireLite RTS451KEY Single Gang Box Conduit to ceiling RI 8 4 Water Flow Switch Supplied by others 1/2' FLex to Deep 4' square box Conduit to ceiling 1.� 9 Sprinkler Valvei Tamper Switch Supplied by others 1/2' FLex to Deep 4' square box Conduit to ceiling Q -%-4 2 Alr Pressure Switch Supplied by others 1/2' FLex to Deep 4' square box Conduit to ceiling 5 Signal Power Booster Altronix AL1002UL-ADA Surface mounted enclosure provided Top 72' AFF conduit to ceiling PB ® 4 Strobe Candella Indicated System Sensor SW or SWH Multi Candella Single or double Gang, 4' square box 80' AFF -to bottom of box 83 Ceiling Strobe Candella Indicated System Sensor SCW or SCWH Multi Candella Single or double Gang, 4' square box Mounted to the ceiling gC � I 112 Horn Strobe Candella Indicated System Sensor P2W or P2WH Multi Candella Single or double Gang, 4' square box 80' AFF to bottom of box EIC 126 Ceiling Horn Strobe Candella Indicated System Sensor PC2W or PC2WH Multi Candella Single or double Gang, 4' square box Mounted to the Ceiling awp 1 Outdoor Horn Strobe Candella Indicated System Sensor P2RK Multi Candella Single or double Gang, 4' square box 84' to 96' AFG to -top of box 1 Auxilary Power Supply Altronix AL4000LX Surface mounted enclosure provided Top 72' AFF conduit -to ceiling PS 2 Power Supervisory Relay A77 -716B 4' Square Box Conduit to ceiling R 0 Isolator Module Firelite I300 4' square deep box ISO SLC Circuit ADT-454747ARE 16 Ga 2 Cond Shielded FPLP Annuciator Circuit ADT-454746ARE 18 Ga 6 Cond Shielded FPLP Power Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Notification Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Duct Detector Test Station ADT-474711ARE 18 Ga 4 Cond FPLP Device Wiring ADT-474711ARE 18 Ga 4 Cond FPLP PAID MAY 212013 TUKWILA FIRE .7o12- 0(-2/2 o/z0(2 This design including specifications, drawings, and design concepts is the property of Tyco Integrated Security (TYCO), and is furnished on a confidential basis, with the expressed understanding that it will not be sold, transfered, copied, or used to the detriment of TYCO without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with TYCO. TYCO makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. 16' 8' 0 16' SCALE 1/16"=1'-0" TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972) 431-1275 FAX: (972) 431-3203 C 4 Southcenter C\2 Seattle, WA Fire Alarm Cover Page Scale: 1116"=1'0" Date: 1/11/2008 Designer: BW Drawn By: DLJ Checked: JCP DWG Date: 12/5/2007 TYCO Confidential Property REVISIONS: BY REV. DATE NOTES: DLJ 1 1/16/2008 Updated per JCP Rev 1 dated 1/11/2008 DU 2 2/14/2008 Updated per JCP Rev 2 dated 1/31/2008 DLJ 3 3/6/2006 Updated per Walkthrough. Removed Puff, added Riser Devices. Added Duct Detectors per Walkthrough. DLJ 4 4/25/2008 Added equipment to release door holders. Added relays to release roll•up gates at mat. Elevators not capable of recall, equipment removed DLJ 5 6/19/2008 Revised per JCP Rev 4 dated 8/13/2008. Revised one Fitting Room, updated mall entrance and Door Holders PLD 6 06/01/2010 Revised per JCP Rev 2 dated 5/19/2010. Removed horn strobe due to fitting room being demo. DLJ 7 4/19/2013 Revised per JCP Shops Drawings. Prepared By: Dusty Jones, ET Fire Alarm Systems, Level Ill - NICET #120752 Expires October 1, 2013 SHEET NO: FA1 SOW l ELEVATOR NOT CAPABLE OF RECALL WIRE WILL BE— RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. • TO PB 30CD C Start ELEVATOR NOT CAPABLE OF RECALL WIRE WILL BE RUN TO ELEVATORS FOR FUME ELEVATOR UPGRADE. TO PB CATALOG STOCK 75CD C 135CD C LOWER CANDELA TO 135CD PB -1 CIR-1A EOL. 115CD C 30CD C STUDIO 0 0 JCP RONE/BATR EVERYDAY Bs BING 115C C PB -2 CIR-M EOL PANTONE 0 MOVE 30CD HORN/STROBE AND CHANGE TO 75CD. 1ncOSERVICE BAR TABLE TOP FOOD PREP COOK/CUT JCP EVERYDA BED & BATH 11INKTIME &-D' aios maw CLOSET 0 30CD RECEPION C COOKWARE/CUOERT r�^����,-"N.^....,-‘.--. ( w ) ( ( (^���®115CD ) (MOVE STROBE TO) COVER DEAD SPOT ( ON OTHER SIDE ^ ( T -WALL ALA ( MUTE GOODS (( ( PB -2 CIR-1B EDL. DEMO KITCHEN KITCHEN l ADD NEW HORN/STROBE TO KITCHEN STORAGE CELEBRATIONS HAPPY CHIC MICHAEL CRAVES 177CD C PB -2 CIR-2A 177CD C MOVE 177CD HORN/STROBE AND / CHANGE TO 185CD. ( ( I ( 0 ( I (, ( of /S ( i� FURNIT RE PB -1 CIR-4B EAL PB -1 CIR-4A E01. GIFTS/VANE & TABLE TOP 1T'CD C SWING HARD WINDOW SOFT mom/WINDOW MEN C CCESS INTIMATE APPAREL ❑_ MOVE 177CD HORN/STROBE AND CHANGE TO 185CD. RELOCATE 5 LOWER CANDELA DEVICES (PC2W & SCW) TO THIS LARGE ROOM. MOVE 177CD HORN/STROBE AND CHANGE TO 135CD. REMOVE El PB -1 CIR-3A EOL 177CD C MOVE TWO 177CD HORN/STROBE DOWN TO COVER NEW SALES AREA. MATTRESS AREA 411 11'4' MI P/O1I1OM 30CD „CaFYE 30 ,1 CIR-3B t-tBC UP TO 2ND FLIER PB -1 CIR-1B EIB. MON ( NET -SELL SMALL SQUARE STOCK ROOM CONVERTED TO LONG STOCK ROOM ALONG OUTER WALL. RELOCATE TWO HORN/STROBES AND A STROBE. ��J �./�J�/`�.��J.J�J�.�../.J���.I �J�..I�./�..1�../�.J`/�J✓�-/J���..I �.I �/�/ ��.J�J.J`/�Iti/�.l`J�J'�./���.I.J.J�.I.����J��`/.J✓��`/`/�./ � SEE REVISOON CLOUDS AND NO ES NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. the roe of Tyco Integrated Security(TYCO), and is furnished on a confidential basis, with the expressed understanding that it will not be sold, transfered, copied, or used b the detriment of TYCO without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with TYCO. TYCO This design including specifications, drawings, and design concepts is property rty y g C makes no reoresentations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. 16' 8' 0 1111111111111111111111 16' SCALE 1/16"=1'-0" TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972) 431-1275 FAX: (972) 431-3203 Southcenter Seattle, WA 98188 1st Floor Fire Alarm Plan Scale: 1/16"=1'0" Date: 1/11/2008 Designer: BW Drawn By: DLJ Checked: JCP DWG Date: 12/5/2007 TYCO Confidential Property REVISIONS: BY REV. DATE NOTES: DLJ 1 1/16/2008 Updated per JCP Rev 1 dated 1/11/2008 DLJ 2 2/14/2008 Updated per JCP Rev 2 dated 13112008 DW 3 3/6/2008 Updated per Walkthrough. Removed Putt, added Riser Devices. Added Duct Detectors per Walkthrough. DLJ 4 4/25/2008 Added equipment to release door holders. Added relays to release roll -up gates at mall. Elevators not capable of recall, equipment removed. DW 5 6/19/2008 Revised per JCP Rev 4 dated 6/13/2008. Revised one Fitting Room, updated mall entrance end Door Holders PLD 6 Revised per JCP Rev 2 06/01/2010 dated 5/19/2010. Removed horn strobe due to fitting room being demo DLJ 7 4/19/2013 Revisedper erJCP Shops Prepared By: Dusty Jones, ET Fire Alarm Systems, Level III - NICET #120752 Expires October 1, 2013 SHEET NO: FA2 PB -3 CIR-3A EEL LL to Z W 2 0 15CD C 30CD C 0 El `_ELEVATOR NOT CAPABLE OF RECAL.. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. D 0 c1771 0 0 CI 177CD C FACP CIR-3 EOL ELEVATOR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS AIWA 30CD --1 TO PH 0 g177CD [84C FINE JEWELRY 0 77CD • 0 0 0 177CD PH -3 CIR-2B EOL 0 0 0 0 0 177CD CI PB -3 CIR-2A EOL ITOPB ,177CD �J177CD IT0 FCP TO PB I TO PB 177CD C 0 0 a 0 CI C 1TOPBi 1177CD C PETITES FlOUT RCM 1/-tl Qt 0 El El CI IDO 10111.1, , NOM WOMENS ACCESS { 0 CfCD 0 0 0 t] E_ OUTERWEAR qIc 177CD PB -2 CIR-4B EIB. SHOES 0 0 0 0 0 0 rd= El El 115CD C ELEVATOR NOT CAPABLE OF RECALL WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. FIRE ALARM RELAY CONNECTED - TO DOOR HOLDERS TO RELEASE DOORS DURING A FIRE ALARM. FIRE ALARM RELAY CONNECT D TO DOOR HOLDERS TO RELEASE DOORS DURING A FIRE ALARM. cT/SIIFiG ELETI1 CAI. PA/Ds PB -3 CIR-IA COL I 1111111111111 i'O II 'iii I II of �,' IIS iji Til I Ili ill I' �I� III III !II Iii PH -3 CIR-IB EEL UPPER LEVEL SHOE STOCK 3OCD IaE t7 E_ El 0 i� POS 177CD C Sin -2 CIR-4A EOL 0 FIRE ALARM RELAY. CONNECTED TO SECURITY GATE TO RELEASE GATE DURING A FIRE ALARM. 30CD I] 1771D IC romeo 7J a30CD 15CD PH -2 CIR 2B EEL 15CD DRESSES E_ WOMENS SIZES WOMENS APPAREL igC ,d,. 17 E_ JUNIORS 0 NEW MALL ENTRANCE PB -2 CIR-3B EDL III LiftL ZOCD i�Mr j�j %Rneo IWs a 0 CI I] a a TO PB 1T75C 30CD ce 0 to Z U i 0 WOMENS FR ANGES L/ GERM kat [475CD t S PB -2 CIR-3A EDI. SARI STARS EE NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. 16' 8' 0 16' SCALE 1/16"=1'-0" TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972) 431-1275 FAX: (972) 431-3203 Southcenter Mall Seattle, WA 98188 Fire Alarm Plan - 2nd Floor Scale: 1/16"= 1' 0" Date: 1/11/2008 Designer: Drawn By: Checked: JCP DWG Date: BW DLJ 12/5/2007 TYCO Confidential Properly REVISIONS: BY REV. DATE NOTES: DW 1/16/2008 Updated per JCP Rev 1 dated 1/11/2008 DLJ 2 2/14/2008 Updated per JCP Rev 2 dated 1/31/2008 DLJ 3 3/6/2008 Updated per Walkthrough. Removed Puft, added Riser Devices. Added Duct Detectors per Waikthrough, DLJ 4 4/25/2008 Added equipment to release door holders. Added relays to release roll -up gates at mall. Elevators not capable of recall, equipment removed. DLJ 5 6/19/2008 Revised per JCP Rev 4 dated 8/13/2008. Revised one Fitting Room, updated mall entrance end Door Holders PLD 6 06/01/2010 Revised per JCP Rev 2 dated 5/19/2010. Removed hom strobe due to fitting room being demo. DLJ 7 4/19/2013 Revised per JCP Shops Drawings. Prepared By: Dusty Jones, ET Fire Alarm Systems, Level III - NICET #120752 Expires October 1, 2013 This design including specifications, drawings, and design concepts is the property of Tyco Integrated Security (TYCO), and is furnished on a confidential basis, with the expressed understanding that it will not be sold, transfered, copied, or used to the detriment of TYCO without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with TYCO. TYCO makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. SHEET NO: FA3 ELEVATOR NOT CAPABLE OF RECALL WIRE WILL BE RUN~ TO ELEVATORS FOR P FUTURE ELEVATOR UPGRADE PB -5 CIR-1B ELL PB -5 CIR-1A EOL 75CD H LOCATE HORN STROBES I _ IN STOCK AREAS F,. 30CD AROIi/D11111111111 BESTSHELLVVING GE�- C 'I ATDR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. A.hFAIfAS 75CD PB -3 CIR-3B ELL ATHLETIC SHOES MEN'S SHOES TO PB MENS CLOTHING a 177CD C 75CD C PB -5 CIR-2A EOL C GIRLS 177CD C iIIIIIIIIIIIIIIIIII MENS IIIIIIIIIIIIIIIIIII 0 ACCESSORIES 177CD C 115CB C PB -4 CIR-4B EOL PB -4 CIR-2B EOL 0 0 0 0 CI 0 a ATHLETIC APPAREL 0 0 115CD 177CD C 0 PORTRAIT STUDIO PLACE 30cd STROBES IN STUDIOS AND/OR CHANGING ROOMS 30CD 30CD PB -4 CIR-3B ELL PB -4 CIR-4A ELL P5-4 CIR-3A EOL NO C A\ GES YOUNG MENS 177CD PB -4 CIR-2A ELL CO FIRE ALARM RELAY CONNECTED TO SECURITY GATE TO RETE SE GATE DURING A FIRE ALARLI. I 0 0 PB -4 CIR-1B EOL PB -4 CIR-1A ELL a S SHEET TO PB 75CD TO PB 110CD (AD -ED -m) - El El Ill DE MO®(1)b U DE Mu ® mo DE ail (A)®(Da SI u (NI ALL RELAYS FOR HVAC SHUTDOWN LOCATED IN ONE AREA El 75CD =® 110CD .. 75CD PENTHOUSE ON ROOF IS NOT TO SCALE DIMENSIONS WERE TAKEN FROM AN OVERHEAD VIEW OF THE SITE PLAN NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. 16' 8' 0 16' SCALE 1/16"=1'-0" TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972) 431-1275 FAX: (972) 431-3203 JCPenney #0696 Southcenter O d Seattle, WA 98188 3rd Floor Alarm Plan • w Scale: 1/16"=1'0" Date: 1/11/2008 Designer: BW Drawn By: DLJ Checked: JCP DWG Date: 12/5/2007 TYCO Confidential Property REVISIONS: BY REV. DATE NOTES: DLJ 1 1/16/2008 Updated per JCP Rev 1 dated 1/11/2008 DU 2 2/14/2008 Updated per JCP Rev 2 dated 1/31/2008 DU 3 3/6/2008 Updated per Walkthrough. Removed Putt, added Riser Devices. Added Duct Detectors per Walkthrough. DLJ 4 4/25/2008 Added equipment to release door holders. Added relays to release roll -up gates at mall. Elevators not capable of recall, equipment removed. DLJ 5 6/19/2008 Revised per JCP Rev 4 dated 8/13/2008. Revised ono Fitting Room, updated mall entrance and Door Holders PLD 6 06/01/2010 Revised per JCP Rev 2 dated 5/19/2010. Removed horn strobe due to titling room being demo. DLJ 7 4/19/2013 Revised per JCP Shops Drawings. Prepared By: Dusty Jones, ET Fire Alarm Systems, Level III - NICET #120752 Expires October 1, 2013 This design including specifications, drawings, and design concepts is the property of Tyco Integrated Security (TYCO), and is furnished on a confidential basis, with the expressed understanding that it will not be sold, transfered, copied, or used to the detriment of TYCO without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with TYCO. TYCO makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. SHEET NO: FA4 Mr 4 (1)21114 FPLP C 3 (1)2614 FPLP Cir 2 (1)21114 FPLP CO' 1 (1)2014 FPLP FireLite MS9600 DACT-UD (1)21116 FPLP (1)24116 FPLP t r , (TiRt). CRcii (* i5 [Ka [Ka («T (« i (*31 (*31 ( -_. •11 •Tk' '!C -.Cr '.TL' -.Cr. 'Ti' HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC Shut Shut Shut Shut Shut Shut Shut Shut Shut Shut Down Down Down Down Down Down Down Down Down Down HVAC "'Saarity Shut Gate Down Reteose II 11 IUUUUUUUUI t), A, t), t), ti, t), t), t), 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, • 4111 4E1/ ▪ CI CI 4 CI Ell 4111 Phone Line 1 Phone Line 2 Flsa Dedicated 120 VAC J 20 Amp Clrcuit(Locked) FireLite BB -26F 122V2SAH l2VV225 H (1) 41118 FPLP FireLite BB -26F System Docvientatlon As BiSit Drawings flax T Box Torpers Bax Tampers Box T Cmbrol Panel PB -I P3-2 P3-3 PBi PB -B ENS HVAC Light Shut Carrtrol Down Jt ALtronic AL4000LX Duct Detector Power I Cir 4A kkkk (1) *14/2 Cir 3A C1) *14/2 Cir 2A 0) 1114/2 ' tmk 1A (1))ir 1114/2 Cir 48 (1) *14/2 Cir 38 CI) *14/2 Cir 2B a) *14/2 Cir 18 (1) *14/2 Altronix 1002ULADA #1 Battery Gro�lnd Dedicated 120 VAC 20 Amp Circuit(Locked) Cir 4A ktalkkk RL k NL (1) *14/2 Cir 3A (1) *14/2 Cir 2A (1) *14/ IRL ml (1)) 14/2 NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. 5. HORNS AND STROBES ARE TO BE MOUNTED 8011 ABOVE THE FINISHED FLOOR TO BOTTOM OF UNIT OR 6" DOWN FROM THE CEILING TO THE TOP OF THE UNIT, WHICHEVER IS LOWER. UNITS NOTED WITH A "C" ARE TO BE CEILING MOUNTED. 6. MANUAL PULL STATIONS ARE TO BE MOUNTED 48" ABOVE THE FLOOR TO THE TOP OF THE UNIT. 7. ALL DEVICES ARE TO BE MOUNTED ON BACK BOXES. 8. WIRE IS TO BE IN CONDUIT TO THE CEILING OR FISHED IN WALLS. 9. CONNECTIONS TO THE POWER SERVICE SHALL BE ON A DEDICATED BRANCH CIRCUIT. THE CiRCUIT AND CONNECTIONS SHALL BE MECHANICALLY PROTECTED THE POWER CIRCUIT SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL". THE LOCATION OF THE DISCONNECTING MEANS SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. Cir 48 (1) *14/2 Cir 38 (1) *14/2 Cir B C) *14/2 Cir 1B U) *14/2 Altronix 1002ULADA #2 Battery Gro�rnd FL l.rttl1 PLl Dedicated 120 VAC 20 Amp Circuit(Locked) IiCir 4A FL kkiRtkk L L ril L '".t 4 FL"'t L " L u i i (1) *14/2 Or 3A (1) *14/2 Cir 2A (1) *14/2 Cir 4B MAAA (1) *14/2 Cir 3B (1) *14/2 Cir 2B (1) *14/2 Cir 1B (1) *14/2 Altronix 1002ULADA #3 Battery Gro�nd Fire Alarm Legend Nk aL al Pi 171 Fib Dedicated 120 VAC 20 Amp Circuit(Locked) Symbol Qty Description Manufacture/Part Number Mounting Requirements FLOORS UL SYSTEM / 1 Fire Alarm Control Panel FireLite MS9600 W/DACT-UD Surface mounted enclosure provided Top 72' AFF conduit to ceiling FCP WJ1055 jFSA1 1 Fire Alam Annunciator Alpha Keypad FireLite LCD -80F Single or double Gang, 4' square box 60' AFF conduit to ceiling 6 Addressable Dual Monitor Module FireLite MDF300 4' square deep box MDF WL1082 PENS00 SILICONE 13 Addressable Monitor Module FireLite MMF300, MMF301 4' square deep box ER SSS100 SEALANT ®P 6 Smoke Detector Photo Electric FireLite SD355 Single Gang, 3.5" Octagon or 4' Sq, Box in the ceiling OR 0 Heat Detector R of R 135 deg or indicated Fire Lite H355R 3 1/4' Octagon box mounted in the ceiling FIRESTOP COLLAR 0 Manual Pull Station FireLite BG-12LX Deep Single Gang Box 48' AFF to Center, Conduit to ceiling P CABLE TRAY STEEL OR A.lJMINUM CA14029 16 Addressable Control Module FireLite CRF -300 4' square deep box CRF CA14020 ®D 25 Duct Smoke Detector Photo Electric FireLite D350PL 1/2' Flex to 4' Square Box 25 Remote indicator Test/Reset FireLite RTS451KEY Single Gang Box Conduit to ceiling RI ', 4 Water Flow Switch Supplied by others 1/2' FLex to Deep 4' square box Conduit to ceiling (QSprinkler s --I-4 9 Valve Tamper Switch Supplied by others 1/2' FLex to Deep 4' square box Conduit to ceiling S-- }�.1 2 Air Pressure Switch Supplied by others 1/2' FLex to Deep 4' square box Conduit to ceiling 5 Signal Power Booster Altronix AL1002UL-ADA Surface mounted enclosure provided Top 72' AFF conduit to ceiling PB 4 Strobe Candella Indicated System Sensor SW or SWH Multi Candella Single or double Gang, 4' square box 80' AFF to bottom of box x( 83 Ceiling Strobe Candella Indicated System Sensor SCW or SCWH Multi Candella Single or double Gang, 4' square bo Mounted to the ceiling XiC E 12 Horn Strobe Candella Indicated System Sensor P2W or P2WH Multi Candella Single or double Gang, 4' square box 80' AFF to bottom of box iCeiling C 126 Horn Strobe Candella Indicated System Sensor PC2W or PC2WH Multi Candella Single or double Gang, 4' square box Mounted to the Ceiling iwp 1 Outdoor Horn Strobe Candella Indicated System Sensor P2RK Multi Candella Single or double Gang, 4' square box 84' to 96' AFG to top of box 1 Auxilary Power Supply Altronix AL4000LX Surface mounted enclosure provided Top 72' AFF conduit to ceiling PS 2 Power Supervisory Relay A77 -716B 4' Square Box Conduit to ceiling R 0 Isolator Module Firelite I300 4' square deep box ISO SLC Circuit ADT-454747ARE 16 Ga 2 Cond Shielded FPLP Annuciator Circuit ADT-454746ARE 18 Ga 6 Cond Shielded FPLP Power Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Notification Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Duct Detector Test Station ADT-474711ARE 18 Ga 4 Cond FPLP Device Wiring ADT-474711ARE 18 Ga 4 Cond FPLP kkqk Cir 4A (1) *14/2 Cir 3A kktqkk (1) *14/2 Cir 2A (1) *14/2 IRL PL 51 Cir 1A " (1) *14/2 Suppled, Installed I. Wired by JC Trtalled Mired bystJCI 24VDC to Next JCI Relay or supervtory relay, SLCLoop To next device Cir 4B (1) *14/2 Cir 38 (1) *14/2 (1 11 * 14/2 /2 Or 1B (1) *14/2 Altronix 1002ULADA #4 Grond krriL 9. RI. Rt. 'l kkkk Dedicated 120 VAC 20 Amp Circuit(Locked) Wire Legend PI 5qc ac Ric (D *14/2 1 Notification Wiring CONCRETE OR MASONARY GYPSUM BOARD/FRAME Fire Alarm Device Wiring FLOORS UL SYSTEM / WALLS UL SYSTEM >} Duct Smoke Power Wiring FIRE RATED PENETRATION SCHEDULE TYPE OF PENETRATiON CONCRETE OR MASONARY GYPSUM BOARD/FRAME "SPECSEAL ram; FLOORS UL SYSTEM / WALLS UL SYSTEM >} FLOORS UL SYSTEM # WALLS UL SYSTEM # METAL CONDUITS ANY SIZE CAJ1079 WJ1055 FC1010 m1049 SSS100 SEALANT CAJ1213 CAJ1213 WJ1088 LC150 SEALANT CAJ1198 CAJ1198 WL1082 PENS00 SILICONE PVC CONDUIT 2' AND SMALLER CAJ2031 WJ2018 FC2032 WL2093 SSS100 SEALANT PVC CONDUITS 2' TNRU 4' C142038 CAJ2O38 FC2033 FC2029 FIRESTOP COLLAR CAi2045 CAJ2045 FIRESTOP COLLAR CAJ2124 CAJ2124 FC2033 WL2059 WRAP STRIPS CABLE TRAY STEEL OR A.lJMINUM CA14029 CAJ4029 WT.4008 FIRESTOP PILLOWS CA 4020 CA14020 FIRESTOP MORTAR C/W4009 814005 SSS100 SEALANT ELECTRICAL BUS DUCT CAJ6009 CA18009 FIRESTOP MORTAR CA18008 CA18008 W18001 SSS100 SEALANT MAX. 3' CABLE BUNDLES CAJ3133 WJ3022 FC3015 WL3076 SSS100 SEALANT MITES; 1. ALL U.L LISTED SYSTEMS SHOWN ABOVE ARE BASED ON PROVIDING A 1 & 2 HOUR RATED FIRESTOP. WHERE 3 HOUR RATING IS REQUIRED. CONTACT FIRESTOP PRODUCT MANUFACTURER FOR DESIGN MODIFICATIONS. 2. ALL U.L LISTED SYSTEMS SHOWN ABOVE ARE BASED ON 'SparSeai Flrestop' PRODUCTS FROM SPECIFIED TECHNOLOGIES, INC. OR APPROVED EQUAL PRODUCTS FROM '3—M' OR HILTi. INC. Devices moulted within 3' of starter motor ND/C/NC Interface Relay - + CRF300 SLC + Red SLC - Black ND/C/NC Installed . BY JCI held Ice and 4./I Insulate. SLC Loop In & Out SWWeldedFPLP Cir 4A (1) *14/2 Cir 3A (1) *14/2 Cir 2A (1) *14/2 Note! All devices must be installed, connected and programed into the fire alram system. Prior to connecting the 24VDC to the power supply in order to prevent the accidental shutdown of all HVAC systems. Duct work Duct detector Supplied I wired by ADT Installed by JCI Cir 48 (1) *14/2 Cir 38 (1) *14/2 Cir 2B tt (1) *14/2 (1))1114/2 Altronix 1002ULADA #5 Battery Ground SLC Loop From FCP or previous device 24VDC from Power supply or previous device Red + Black _ Dedicated 120 VAC 20 Amp Circuit(Locked) 16' 8' 0 16' ENEN SCALE 1/16"=1'-0" TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLATO, TEXAS 75024 PH: (972) 431-1275 FAX: (972) 431-3203 Southcenter Seattle, WA 98188 Fire Alarm Riser Diagram Scale: 1/16"=1'0" Date: 1/11/2008 Designer: BW Drawn By: DLJ Checked: JCP DWG Date: 12/5/2007 TYCO Confidential Properly REVISIONS: BY REV. DATE NOTES: DLJ 1/18/2008 Updated per JCP Rev 1 dated 1/11/2008 DU 2 2/14/2008 Updated per JCP Rev 2 dated 1/31/2008 DU 3 3/8/2008 Updated per Walkthrough. Removed Putt, added Riser Devices. Added Duct Detectors per Walkthrough. DLJ 4 4/25/2008 Added equipment to release door holders. Added relays to release rolPup gates at mall. Elevators not capable of recall, equipment removed. DU 5 6/19/2008 Revised per JCP Rev 4 dated 6/13/2008. Revised one Filling Room, updated mall entrance end Door Holders PLD 6 06/01/2010 Revised per JCP Rev 2 dated 5/19/2010. Removed horn strobe due to fitting room being demo. DLJ 7 4/19/2013 Revised per JCP Shops Drawings. Prepared By: Dusty Jones, ET Fire Alarm Systems, Level III - NICET #120752 Expires October 1, 2013 This design including specifications, drawings, and design concepts is the property of Tyco Integrated Security (TYCO), and is furnished on a confidential basis, with the expressed understanding that it will not be sold, transfered, copied, or used to the detriment of TYCO without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with TYCO. TYCO makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. SHEET NO: FA5 JCPenney Standard Fire Alarm Zoning FireLite MS9600 . Reporting Zone # Address Number Device Software Zone Software Zone Software Zone Current NAC #1 System sensor Sync 1 2 MS9600 Fre Alarm Control 1 0.120000 NAC #2 System sensor Sync 1 2 0.100000 0.132000 0.132000 NAC #3 System sensor Sync 1 2 SD355 Smoke Detector Photo 6 0.000300 NAC #4 System sensor Sync 1 2 0.004500 0.006400 0.038400 Relay #1 Alarm 1 2 TvF 301 Monitor Nodule Small 8 0.000375 Relay #2 Trouble 4 Control Module Relay 16 0.000270 0.004320 0.006500 0.104000 Relay #3 Supervisory 3 0.007500 RTS451 KEY Loop #1 Module Addresses 0.300000 0.740 Total4 Maximum 2.5Arrps 1.480 180 1 Box Tampers Control 3 0.000000 0.000000 161 2 Box Tampers Battery Box 3 x Signal Circuits 163 4 Water flow #1 1 Alarm Current 164 5 Sprinkler Tamper Switch #1 3 Circuit 1 AL1o02UL-ADP-J 165 6 Water flow #2 1 Alarm Amp Hours Req. 0.680 0.000 166 7 Sprinkler Tamper Switch #2 3 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 167 8 Waterflow#3 1 x 0.000 168 9 Sprinkler Tamper Switch #3 3 0.000 169 10 Sprinkler Tamper Switch #4 3 Circuit 1A Circuit 2A Circuit 3A 0.000 170 11 Sprinkler Tamper Switch #5 3 Total2 Maximum 2.5 Amps 171 12 Sprinkler Tamper Switch #6 3 0.212 0.212 172 13 Dry Water flow #1 1 x 173 14 Dry Sprinkler Tamper Switch #1 3 Calculations assume that all devices are at the end of the line. 0.000 174 15 Air Pressure Switch High 3 Circuit 4 175 16 Air Pressure Switch Low 1 0.000 176 17 Outside PIV #1 3 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 177 18 Outside PIV #2 3 0.000 178 19 Box Tampers Power Supply 3 Circuit 1 Circuit 2 179 20 Box Tampers Power Expander #1 3 3073 180 21 Box Tampers Power Expander #2 3 Voltage Drop for 14 AWG w ire 181 22 Box Tampers Power Expander #3 3 Abnormal circuit or device 1 182 23 Box Tampers Power Expander #4 3 Standby Hours 60 183 24 Box Tampers Power Expander #5 3 228 69 Security Gate Release 1 2 229 70 Security Gate Release 1 2 230 71 Door Holders Release 1 2 1.095 233 74 EMS Light control 1 2 0.091 252 93 HVAC #1 Shutdown 41 253 94 HVAC #2 Shutdown 42 254 95 HVAC #3 Shutdown 43 and 20% Reserve 255 96 HVAC #4 Shutdown 44 256 97 HVAC #5 Shutdown 45 25 A.H. 257 98 HVAC #6 Shutdown 46 258 99 HVAC #7 Shutdown 47 259 100 HVAC #8 Shutdown 48 260 _ 101 HVAC #9 Shutdown 49 261 102 HVAC #10 Shutdown 50 262 103 HVAC #11 Shutdown 51 263 104 HVAC #12 Shutdown 52 272 113 EOL Power Supervision MMF 61 273 114 EOL Power Supervision MMF 62 Detector Addresses 001 1 Smoke Detector at panel 2 002 2 Smoke Detector at Penthouse 2 003 3 Smoke Detector at Door Holders 2 004 4 Smoke Detector at Door Holders 2 005 5 Smoke Detector at Door Holders 2 006 6 Smoke Detector at Door Holders 2 021 21 AHU #1 Supply Duct Detector 3 41 022 22 AHU #1 Return Duct Detector 3 41 023 23 AHU #2 Supply Duct Detector 3 42 024 24 AHU #2 Return Duct Detector 3 42 025 25 AHU #3 Supply Duct Detector 3 43 026 26 AHU #3 Return Duct Detector 3 43 027 27 AHU #4 Supply Duct Detector 3 44 028 28 AHU #4 Return Duct Detector 3 44 029 29 AHU #5 Supply Duct Detector 3 45 030 30 AHU #5 Return Duct Detector 3 45 031 31 AHU #6 Supply Duct Detector 3 46 032 32 AHU #6 Return Duct Detector 3 46 033 33 AHU #7 Supply Duct Detector 3 47 034 34 AHU #7 Return Duct Detector 3 47 035 35 AHU #8 Supply Duct Detector 3 48 036 36 AHU #8 Return Duct Detector 3 48 037 37 AHU #9 Supply Duct Detector 3 49 038 38 AHU #9 Return Duct Detector 3 49 039 39 AHU #10 Supply Duct Detector 3 50 040 40 AHU #10 Return Duct Detector 3 50 041 41 AHU #11 Supply Duct Detector 3 51 042 42 AHU #11 Return Duct Detector 3 51 043 43 AHU #12 Supply Duct Detector 3 52 044 44 AHU #12 Return Duct Detector 3 52 Sequence of Operation Standby Battery Calculations FireLite MS9600 JCPenney SEATTLE WA 98188 AL1002U--ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Part Number Standby Current Alarm Description Quantity Per Device All Devices Per Device Standby Current Alarm Current Part Number Description Quantity Par Device All Devices Per Device All Devices MS9600 Fre Alarm Control 1 0.120000 0.120000 0.170000 0.170000 DACT UD Dual Line Dialer 1 0.100000 0.100000 0.132000 0.132000 LCD -80F Annunciator LCD 1 0.025000 0.025000 0.064000 0.064000 SD355 Smoke Detector Photo 6 0.000300 0.001800 0.006500 0.039000 MOP -300 Monitor Module Dual Input 6 0.000750 0.004500 0.006400 0.038400 MN1F-300 Monitor Module Single input 5 0.000400 0.002000 0.005100 0.025500 TvF 301 Monitor Nodule Small 8 0.000375 0.003000 0.000375 0.003000 CRF -300 Control Module Relay 16 0.000270 0.004320 0.006500 0.104000 D350PL Duct Smoke Detector 25 0.000300 0.007500 0.000300 0.007500 RTS451 KEY Remote test Sw itch 25 0.012000 0.300000 0.012000 0.300000 0.740 Total4 Maximum 2.5Arrps 1.480 0.000000 0.000000 Air Pressure Low x 0.000000 0.000000 x Total Aux current Max 3 Amps 0.568 Alarm 0.883 x Signal Circuits x x x Standby Battery Draw 0.090 Alarm Current Circuit Device Quantity, Per Device All Devices Circuit 1 AL1o02UL-ADP-J 0.175 0.000 Alarm Anp Hours Req. 0.742 0.000 Alarm Amp Hours Req. 0.680 0.000 x Battery Size Required with 0.000 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 0.000 Total/ Maximum 2.5 Amps x 0.000 Circuit 2 AL1002UL-ADA-J 0.175 0.000 0.000 Total 4 Maximum 2.5 Atrps 0.000 Totals Maximum 10 Arrps 3.101 Circuit 1A Circuit 2A Circuit 3A 0.000 Max Wre Run Distance For AWG 14 668 910 Smoke detectors Actual Wre run Distance 450 375 0.000 Total2 Maximum 2.5 Amps Circuit 18 Circuit 2B Circuit 3B 0.000 Circuit 3 P2RK-110 1 0.212 0.212 Voltage Drop for 14 AWG w ire 2.137 1.326 Voltage Drop = 2' Wre Run Distance • 3.07 Ohms Per 1000 ft 14 AWG* Total Current for Circuit / 1000 0.000 x Standby Hours 60 0.000 Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. 0.000 Total 3 Maximum 2.5 Amps x 0.212 Circuit 4 Alarm Battery Draw 3.276 0.000 AlarrnArrp Hours Req. 0.273 0.000 Battery Size Required with 0.000 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 0.000 Total 4 Maximum 2.5 Amps 0.000 Totals Maximum 6 Amps x 0.212 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Max Wre Run Distance For AWG 14 3073 Actual Wre run Distance 100 Voltage Drop for 14 AWG w ire 0.130 Voltage Drop = 2 *Wre Run Distance * 3.07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit / 1000 Abnormal circuit or device 1 x Standby Hours 60 Standby Battery Draw 0.568 Standby Amp Hours Req. 14.700 Alarm Mnutes 5 Alarm Battery Draw 1.095 Alarm Any Hours Req. 0.091 Battery Size Required with 0.56812 Standby hours, 5 Alarm minutes and 20% Reserve 17.677 I I Battery Size Supplied 25 A.H. Sequence of Operation Standby Battery Calculations Altronix AL4000LX JCPenney SEATTLE, WA 98188 AL1002U--ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Part Number Standby Current Alarm Description Quantity Per Device All Devices Per Device Current All Devices AL4000LX Power Supply 4A 62;12 or 3A @ 24VE 1 0.060 0.060 0.080 0.060 Shuts dawn associated AHU/RTU • Auxiliary devices Maximum 3 Arrps Release Shoe Stock Door Holders A77 -716B Power Supervisory Relay Total Aux current 2 0.019 0.038 0.000 Max 3 Arrps 0.098 0.019 Alarm I 0.038 0.000 0.098 Standby Hours 24 Standby Battery Draw 0.098 Standby Anp Hours Req. 2.352 x Alarm Mnutes 5 Alarm Battery Draw 0.098 AlarmAnp Hours Req. 0.008 Total 1 Maximum 2.5 Anps 2.062 Battery Size Required with 24 Standby hours, 5 Alarm ninutes and 20% Reserve 2.832 x 'Battery Size Supplied 7 A.H. x Sequence of Operation Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All devices AL1002U--ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Annunciate alarm signal at control panel and remote annunciator Annunciate supervisory signal at control pane and remote annunciator Annunciate trouble signal at control pane and remote annunciator Transmits alarm signal to UL Med monitoring center Transmits supervisory signal to UL listed monitoring center Transmits trouble to UL listed monitoring center. Shuts dawn associated AHU/RTU Release Security Gate Release Shoe Stock Door Holders Turn on Lights through EMS Light Control Activates interior horns and strobes Activates exterior horn strobe Sprinkler system Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All devices AL1002U--ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1A PC2W30 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 Water flow x SCW-30 3 0.094 0.282 0.000 x 1.031 Total 1 Maximum 2.5 Anps 2.062 Circuit 2A PC2WH-177 2 0.290 0.580 x x x x x 0.000 Valve tamper 0.000 x Total 2 Maximum2.5Arrps 2.291 Circuit 3A PC2W75 2 0.176 0.352 x SCW-15 2 0.066 0.132 0.000 0.912 Circuit 3B PC2W75 4 0.176 0.704 PC2W-30 5 0.107 0.535 0.000 0.000 1.239 Air Pressure High Circuit 4A P2W-75 3 0.176 0.528 x 0.000 0.000 x Circuit 4B P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 0.000 0.000 0.740 Total4 Maximum 2.5Arrps 1.480 Totals Maximum 10 Amps 7.984 Circuit 1A Circuit 2A Orcuit 3A Circuit 4A Air Pressure Low x Voltage Drop for 14 AWG wire 3.482 3.299 2.520 2.499 Circuit 1B Circuit 28 Crcuit 3B Circuit 4B x Actual Wre run Distance 575 350 450 550 Voltage Drop f or 14 AWG w ire 3.640 2.493 3.423 2.499 Voltage Drop = 2 * Wre Run Distance' 3.07 Ohne Fer 1000 ft 14 AVVG'Total Current for Circuit / 1000 x x x x x Standby Battery Draw 0.090 Standby Anp Hours Req. 5.400 Calculations assume that all devices are at the end of the line. Standby Amp Hours Req. 5.400 0.000 Circuit 3B Alarm Mnutes 5 Alarm Mnutes 5 Alarm Battery Draw 8.159 Alarm Anp Hours Req. 0.742 0.000 Alarm Amp Hours Req. 0.680 Manual pull station x Battery Size Required with x 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 x x x x 0.000 0.000 0.000 0.000 Total 4 Maximum 2.5 Atrps 0.000 Totals Maximum 10 Arrps 3.101 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wre Run Distance For AWG 14 668 910 Smoke detectors Actual Wre run Distance 450 375 Voltage Drop for 14 AWG w ire 2.694 1.649 Circuit 18 Circuit 2B Circuit 3B Circuit 4B Max Wre Run Distance For AWG 14 749 1206 Actual Wire run Distance 400 400 Voltage Drop for 14 AWG w ire 2.137 1.326 Voltage Drop = 2' Wre Run Distance • 3.07 Ohms Per 1000 ft 14 AWG* Total Current for Circuit / 1000 at panel x Standby Hours 60 x Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. x x x x Alarm Mnutes 5 Alarm Battery Draw 3.276 AlarrnArrp Hours Req. 0.273 Battery Size Required with 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 Duct smoke detectors I x x x Abnormal circuit or device x x System Outline Location JCPenney 0696-5 1249 SOUTHCENTER MALL SEATTLE, WA 98188 Codes A. NFPA 72 Are Alarm Code B. NFR4 70 National Electrical Code C. Local, City, or State Codes III. Control A. B. C. D. 1 MS9600 1 DACT-UD 5 AL1002UL-ADA-J 1 AL4000LX N. Are Alarm Initiating Devices A. B. C. D. E 6 SD355 25 D350PL 4 Water Flow 9 Tamper Sw itch 2 Air Pressure V. Fire Alarm Indicating Devices A. 1 LCD -80F B. 2 PC2Wi-185 C. 42 PC2Wl-177 D. 2 PC2w1.135 E 3 PC2W-115 F. 27 PC2W-75 G. 46 PC2W-30 H 3 PC2W-15 1 2 P2W-110 J. 6 P2W-75 K 4 P2VV-30 L. 4 SCW -177 M 9 SCW-115 N. 17 SCW-75 O. 45 SCW-30 P. 9 SCW-15 Q. 2 SW -30 R 2 SW -15 S. 1 P2RK-110 VI. Zones All devices are addressable with there own address 1-159 detector addresses 1-159 module addresses SLC Loop is style 4 Fire Alarm Control Dual Line Dialer ADA Power Booster 10A@24VDC Power Supply 4A @ 12 or 3A @ 24VDC Smoke Detector Photo Duct Smoke Detector Connection Only, Provided by Others Connection Only, Provided by Others Connection Only, Provided by Others Annunciator LCD Ceiling Horn strobe WHITE24VDC 185CD Ceiling Horn strobe WHITE 24VDC 177CD Ceiling Horn strobe WHITE24VDC 135CD Ceiling Horn strobe WHI1E24VDC 115CD Ceiling Horn strobe WHITE 24VDC 75CD Ceiling Horn strobe WHfIE24VDC 30CD Ceiling Horn strobe WHITE 24VDC 15CD Wall Horn strobe WI-UTE24VDC 110CD Wall Horn strobe MITE 24VDC 75CD Wall Horn strobe MITE 24VDC 30CD Ceiling Strobe WiITE24VDC 177CD Ceiling Strobe WHITE24VDC 115CD Ceiling Strobe WHITE 24VDC 75CD Ceiling Strobe VVHr E 24VDC 30CD Ceiling Strobe WHITE 24VDC 15CD Wall Strobe WHITE 24VDC 30CD VII Wring All Circuits and Wring Shall be "Power Limited" SLC Circuits Shall be 16/2 Shielded U.L. FPLP Cable Initiating Zones Shall be 18/2 or 18/4 U.L. FPLPCable Indicating Circuits Shall be 14/2 U.L. FPLP Cable System Ground Shall be 14 THWN Green Conductor Under Ground and Outside Wre shall be 14 THWN in Approved Raceway VIII. Listings A. All Equipment Shall Be U.L. Listed and Compatible a. Power Supply A. Primary -110 VAC Dedicated 20 Anp Circuit B. Secondary - 25 Anp Hour Battery x. Alarm Supervision A. flumen B. Remote Station ADT Fire & Security 14200 EExposition Blvd. Aurora, CO 80012 (303) 338-8200 S994-183 UUFX Installing Branch/Contractor ADT Tyco Are & Security 11824 No Creek Parlw ay Bothell, WA 98011 (206) 624-3103 Standby Battery Calculations Altronix AL1002ULADA #3 JCPenney SEATTLE, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All devices AL1002U--ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1A PC2W30 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 1.031 Circuit 1B PC2W30 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 1.031 Total 1 Maximum 2.5 Anps 2.062 Circuit 2A PC2WH-177 2 0.290 0.580 PC2W-75 1 0.176 0.176 SCW30 1 0.094 0.094 SCVVH-177 1 0.281 0.281 1.131 Circuit 2B PC2VUI+177 4 0.290 1.160 0.000 0.000 0.000 1.160 Total 2 Maximum2.5Arrps 2.291 Circuit 3A PC2W75 2 0.176 0.352 PC2W-30 4 0.107 0.428 SCW-15 2 0.066 0.132 0.000 0.912 Circuit 3B PC2W75 4 0.176 0.704 PC2W-30 5 0.107 0.535 0.000 0.000 1.239 Total 3 Maximum 2.5 Anps 2.151 Circuit 4A P2W-75 3 0.176 0.528 P21/11-110 1 0.212 0.212 0.000 0.000 0.740 Circuit 4B P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 0.000 0.000 0.740 Total4 Maximum 2.5Arrps 1.480 Totals Maximum 10 Amps 7.984 Circuit 1A Circuit 2A Orcuit 3A Circuit 4A Max Wre Run Distance For AWG 14 632 576 714 880 Actual Wre run Distance 550 475 450 550 Voltage Drop for 14 AWG wire 3.482 3.299 2.520 2.499 Circuit 1B Circuit 28 Crcuit 3B Circuit 4B Max Wre Run Distance For AWG 14 632 562 526 880 Actual Wre run Distance 575 350 450 550 Voltage Drop f or 14 AWG w ire 3.640 2.493 3.423 2.499 Voltage Drop = 2 * Wre Run Distance' 3.07 Ohne Fer 1000 ft 14 AVVG'Total Current for Circuit / 1000 Calculations are based on a nininum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Standby Anp Hours Req. 5.400 Calculations assume that all devices are at the end of the line. Standby Amp Hours Req. 5.400 0.000 Circuit 3B Alarm Mnutes 5 Alarm Mnutes 5 Alarm Battery Draw 8.159 Alarm Anp Hours Req. 0.742 0.000 Alarm Amp Hours Req. 0.680 0.000 Circuit 4A Battery Size Required with Battery Size Required with 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 I Battery Size Supplied 18 A.H. 0.000 Battery Size Supplied 18 A.H 0.000 Standby Battery Calculations Altronix AL1002ULADA #1 JCPenney SEATTLE WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device AU Devices Per Device Alt Devices AL1002UL-ADA-J ADA Power Booster 10AG24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1A PC2W-30 2 0.107 0.214 SCW-30 3 0.094 0.282 PC2W-75 1 0.178 0.176 SCW75 1 0.158 0.158 PC21MH•135 1 0.245 0.245 1.075 Circuit 1B PC2W-75 3 0.176 0.528 SCW-75 1 0.158 0.158 PC2W-30 2 0.107 0.214 SCW-30 2 0.094 0.188 1.088 Total 1 Maximum 2.5 Amps 2.163 Circuit 2A PC2WH-185 2 0.297 0.94 PC2VN+177 1 0.290 0.290 PC2WH•135 1 0.245 0.245 0.000 1.129 Circuit 2B PC2VVH•177 3 0.290 0.870 SCW-115 1 0.210 0.210 0.000 1.080 Total 2 Maximum 2.5 Anps 2.209 Circuit 3A PC2Wl-I-177 3 0.290 0.870 SCW-115 1 0.210 0.210 SCW75 1 0.158 0.158 0.000 1.238 Circuit 38 SCW-30 3 0.094 0.282 FC2W30 1 0.107 0.107 PC2W75 2 0.176 0.352 PC2W4177 1 0.290 0.290 1.031 Total 3 Maximlrn25Arrps 2.269 Circuit 4A PC2Wi-l.177 2 0.290 0.580 SCW115 1 0.210 0.210 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 1.060 Circuit 48 SCW-30 1 0.094 0.094 PC2W-30 1 0.107 0.107 PC2W-75 2 0.176 0.352 SCW-75 3 0.158 0.474 1.027 Total 4 Maximum 2.5 Amps 2.087 Totals Maximum 10 Amps 8.728 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 606 577 526 615 Actual Wre run Distance 375 400 350 375 Voltage Drop for 14 AWG w ire 2.475 2.773 2.660 2.441 Circuit 18 Circuit 2B Circuit 3B Circuit 4B Max Wre Run Distance For AWG 14 599 603 632 634 Actual Wre run Distance 525 300 550 550 Voltage Drop for 14 AWG w ire 3.507 1.989 3.482 3.468 Voltage Drop = 2 *Wre Run Distance * 3.07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit / 1000 Calculations are based on a n ininum supply voltage of 20.4 Volts 1.256 Circuit 3A Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Anp Hours Req. 5.400 0.000 0.000 Circuit 3B Alarm Mnutes 5 Alarm Battery Draw 8.903 0.000 Alarm Anp Hours Req. 0.742 0.000 Total 3 Maximum 2.5 Anps 0.000 Circuit 4A Battery Size Required with 60 Standby hours, 5 Alarm ninutes and 20% Reserve 7.370 0.000 I Battery Size Supplied 18 A.H. 0.000 Standby Battery Calculations Altronix AL1002ULADA #2 JCPenney SEATTLE, WA 98188 Standby Current Alarm Current Part Number Description Quantity ler Device All Devices lar Device AU Devices AL1002UL-ADA-J ADA Power Booster 10A@24VOC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum3 Anps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Anps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device AU Devices Circuit 1A SCW-30 5 0.094 0.470 SCVV-76 1 0.158 0.158 PC2W-30 1 0.107 0.107 PC2W75 1 0.176 0.176 SCW-15 1 0.066 0.066 SCW-115 1 0.210 0.210 1.187 Circuit 1B PC2WH-177 1 0.290 0.290 PC2W-30 1 0.107 0.107 SCW-30 2 0.094 0.188 SCW-15 1 0.066 0.068 SCW-75 2 0.158 0.316 0.967 Total1 Maximum 2.5Anps 2.154 Circuit 2A SCW-30 4 0.094 0.376 PC2W-30 2 0.107 0.214 SCW-75 1 0.158 0.158 0.748 Circuit 2B PC2W-30 1 0.107 0.107 SW -30 2 0.094 0.188 P2W-30 4 0.107 0.428 SW -15 2 0.066 0.132 0.855 Total 2 Maximum 2.5 Amps 1.603 Qrcuit 3A PC2WT+177 3 0.290 0.870 PC2W-75 • 1 0.176 0.178 SCW-30 1 0.094 0.094 1.140 Circuit 3B SCWH-177 2 0.281 0.562 PC2W115 1 0.218 0.218 PC21M-E177 2 0.290 0.580 0.000 1.360 Total 3 Maximum 2.5 Anps 2.500 Circuit 4A PC2VVH-177 4 0.290 1.160 0.000 0.000 1.160 Circuit4B PC2UN+177 2 0.290 0.580 PC2W-30 3 0.107 0.321 SCW-75 1 0.158 0.158 0.000 1.059 Total 4 Maximum 2.5 Amps 2.219 Totals Ntaximum 10 Amps 8.476 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wre Run Distance For AMG 14 549 871 571 562 Actual Wre run Distance 425 525 425 350 Voltage Drop for 14 AV wire 3.097 2.411 2.975 2.493 Circuit 1B Circuit 2B Circuit 3B Circuit 48 Max Wire Run Distance For AWG 14 674 762 479 615 Actual Wre run Distance 450 500 350 525 Voltage Drop for 14 AWG w ire 2.672 2.625 2.923 3.414 Voltage Drop = 2 • Wire Run Distance* 3.07 Ohms Per 1000 ft 14 AWG* Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts 1.256 Circuit 3A Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Arrp Hours Req. 5.400 0.000 0.000 Circuit 3B Alarm Mnutes 5 Alarm Battery Draw 8.651 0.000 Alarm Anp Hours Req. 0.721 0.000 Total 3 Maximum 2.5 Anps 0.000 Circuit 4A Battery Size Required with 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 0.000 I !Battery Size Supplied 18 A.H. 0.000 Standby Battery Calculations Altronix AL1002ULADA #4 JCPenney SEATTLE, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All Devices AL1002UL-ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Anps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Par Device AU Devices Circuit 1A SCWH-177 1 0.281 0.281 SCiN-75 2 0.158 0.316 SCW30 3 0.094 0.282 PC2W-115 1 0.218 0.218 1.097 Circuit 1B PC2WI+177 4 0.290 1.160 0.000 0.000 0.000 1.160 Total/ Maximum 2.5 Anps 2.257 Circuit 2A PC2VVH-177 1 0.290 0.290 PC2W-30 2 0.107 0.214 SCW-115 1 0.210 0.210 PC2W-115 1 0.218 0.218 0.932 Circuit 2B PC 2VV -177 3 0.290 0.870 SCW-115 1 0.210 0.210 PC2W-30 1 0.107 0.107 0.000 1.187 Total 2 Maxinum2.5Arrps 2.119 Circuit 3A PC2W1-177- 1 0.290 0.290 SCW-115 1 0.210 0.210 PC2W75 2 0.176 0.352 0.852 Circuit 3B PCWH-177 3 0.290 0.870 PC2W-75 1 0.176 0.176 0.000 1.046 Total3 Maximum 2.5 Amps 1.898 Circuit 4A PC2WH-177 1 0.290 0.290 SCW-115 1 0.210 0.210 PC2W-75 1 0.176 0.176 SCW-30 3 0.094 0.282 0.958 Orcuit 4B SCW-115 1 0.210 0.210 SCW-15 2 0.066 0.132 SON -30 1 0.094 0.094 SCW-75 1 0.158 0.158 PC2W-75 1 0.176 0.176 PC2WI-l-177 1 0.290 0.290 1.060 _ Total 4 Maximum2.5Amps 2.018 Totals Maximum 10 Arrps 8.292 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wre Run Distance For AWG 14 594 699 765 680 Actual Wire run Distance 550 450 425 550 Voltage Drop for 14 AWG wire 3.705 2.575 2.223 3.235 Circuit 1B Circuit 28 Circuit 38 Circuit 4B Max Wire Run Distance For A WG 14 562 549 623 615 Actual Wire run Distance 425 425 425 500 Voltage Drop for 14 AWG wire 3.027 3.097 2.730 3.254 Voltage Drop = 2' Wre Run Distance' 3.07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts 1.256 Circuit 3A Standby Hours 60 and a minimum voltage at the end of rine of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Arrp Hours Req. 5.400 0.000 0.000 Circuit 3B Alarm Minutes 5 Alarm Battery Draw 8.467 0.000 Alarm Any Hours Req. 0.706 0.000 Total 3 Maximum 2.5 Anps 0.000 Circuit 4A Battery Size Required with 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 0.000 0.000 Battery Size Supplied 18 A.R 0.000 Standby Battery Calculations Altronix AL1002ULADA #5 JCPenney SEATTLE, WA 98188 Standby Current Part Number Description Quantity Per Device Alt Devices Alarm Current Per Device All Devices AL1002UL-ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices futaxinum3 Amps 0.000 0.000 Total Aux current Max 3 Anps 0.090 0.000 0.000 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Par Device All Devices Circuit 1A PC2W30 5 0.107 0.535 SCW-30 3 0.094 0.282 SCW-75 1 0.158 0.158 0.000 0.975 Circuit 1B PC2W-30 1 0.107 0.107 PC2W-15 1 0.079 0.079 PC2W-75 1 0.176 0.176 SCW30 4 0.094 0.376 SON -15 2 0.066 0.132 0.870 Total I Maximum 2.5 Arrps 1.845 Circuit 2A 0.000 PC2W-75 1 0.176 0.176 PC2W15 2 0.079 0.158 SCW-15 1 0.066 0.066 SCW-75 2 0.158 0.316 0.716 Circuit 2B PC2W-75 2 0.176 0.352 SON -30 2 0.094 0.188 0.000 0.000 0.540 Total 2 Maximum 2.5 Anps 1.256 Circuit 3A 0.000 0.000 0.000 0.000 0.000 Circuit 3B 0.000 0.000 0.000 0.000 Total 3 Maximum 2.5 Anps 0.000 Circuit 4A 0.000 0.000 0.000 0.000 0.000 Circuit 4B 0.000 0.000 0.000 0.000 Total 4 Maximum 2.5 Atrps 0.000 Totals Maximum 10 Arrps 3.101 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wre Run Distance For AWG 14 668 910 Actual Wre run Distance 450 375 Voltage Drop for 14 AWG w ire 2.694 1.649 Circuit 18 Circuit 2B Circuit 3B Circuit 4B Max Wre Run Distance For AWG 14 749 1206 Actual Wire run Distance 400 400 Voltage Drop for 14 AWG w ire 2.137 1.326 Voltage Drop = 2' Wre Run Distance • 3.07 Ohms Per 1000 ft 14 AWG* Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts r Standby Hours 60 and a ninirrumvoltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Anp Hours Req. 5.400 Alarm Mnutes 5 Alarm Battery Draw 3.276 AlarrnArrp Hours Req. 0.273 Battery Size Required with 0.09 Standby hours, 5 Alarm minutes and 20% Reserve 6.498 I Battery Size Supplied 18 A.H 16' 8' 0 16' SCALE 1/16"=l'-0" TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972) 431-1275 FAX: (972) 431-3203 C cts 1200 Sauthcenter Seattle, WA Fire Alarm Battery Cales Scale: 1/16"=1'0" Date: 1/11/2008 Designer: BW Drawn By: DLJ Checked: JCP DWG Date: 12/5/2007 TYCO Confidential Property REVISIONS: BY REV. DATE NOTES: DLJ 1/16/2008 Updated per JCP Rev 1 dated 1/11/2008 DLJ 2 2/14/2008 Updated per JCP Rev 2 dated 1/31/2008 DLJ 3 3/6/2008 Updated per Walkthrough. Removed Putt, added Riser Devices. Added Duct Detectors per Walkthrough. DLJ 4 4/25/2008 Added equipment to release door holders. Added relays to release roll -up gates at mall. Elevators not capable of recall, equipment removed. DLJ 5 6/19/2008 Revised per JCP Rev 4 dated 0/13/2008. Revised one Fitting Room, updated mall entrance and Door Holders PLD 6 06/01/2010 Revised per JCP Rev 2 dated 5/18/2010. Removed horn strobe due to fitting room being demo. DLJ 7 4/19/2013 Revised per JCP Shops Drawings. Prepared By: Dusty Jones, ET Fire Alarm Systems, Level III - NICET #120752 Expires October 1, 2013 This design including specifications, drawings, and design concepts is the property of Tyco Integrated Security (TYCO), and is furnished on a confidential basis, with the expressed understanding that it will not be sold, Iransfered, copied, or used to the detriment of TYCO without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with TYCO. TYCO makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. SHEET NO: FA6 Owner information JCPenney 6501 Legacy drive Plano, TX (972) 431-1000 Real Estate Dept. Installing contractor ADT Security Service 11824 No Creek Parkway Bothell, WA 98011 (206) 624-3103 Fire alarm designer ADT Security Service Brad Welch CET 104032 120 West Park Dr. Birmingham, AL 35211 (205) 943-6520 Code Section NFPA 72 Fire alarm code 2002 Edition NFPA 70 National electrical code 2002 Edition International Fire Code 2006 edition as amended International Building Code 2006 edition as amended International Mechanical Code 2006 edition as Amended ANSI 117.1 Accessibility code. Scope of work Replacement addressable fire alarm system. The fire alarm control panel and all power supplies are to be mounted in the sprinkler room. They are to be powered by dedicated 120VAC circuits that are to be locked and labeled FIRE ALARM DO NOT TURN OFF. The fire alarm is to be monitored as a remote station at ADT Security service, Aurora, CO. By a dual line dialer connected to 2 existing shared loop start phone lines. The following conditions are to be monitored. All water flow switches as alarm. All sprinkler valves as a supervisory. Smoke detector at the fire alarm panel per NFPA 72. Manual pull stations the fire panel, as alarm. Duct detectors are to be installed in the Supply and Return duct and monitored as a supervisory signal. The duct detectors are to shut down their own unit. Occupant notification is to be public mode. All horns and strobes shall be synchronized. Fire Alarm Device Locations 1st Floor Monitoring Center ADT Security Service 14200 Exposition Ave Aurora, CO 80012 Phone (303) 338-8200 UL Listing Number S994- 183 UUFX Fire Department Contact Tukwilla Fire Prevention 444 Andover Park East Tukwilla, WA 98188 (206) 575-4404 Al Metzler General notes: 1. All fire alarm devices are to be installed according the the requirements of NFPA 72 and the manufactures instructions. 2. All fire alarm devices are to be mounted on back boxes. 3. All fire alarm devices are to be UL Listed and compatible. 4. All wire is to be in conduit from the device back box to above the false ceiling or to the bar joists. Wire may be run exposed horizontally but must be attached to the building structure or supported by approved hangers. 5. All wire is to be Power Limited, Type FPLP unless otherwise noted. All wiring is to be installed in accordance with the adapted NFPA 70 (NEC Section 760), NFPA 72 and all local codes. 6. Control panels and power supplies are to be mounted in the sprinkler room unless the AHJ requires otherwise. They are to be mounted no more that 72 inches above the floor to the top of the cabinet. 7. Annunciator/Keypads are to be mounted at 60 inches above the floor to the top of the unit unless the AHJ requires otherwise. 8. Manual pull stations are to be mounted at 48 inches above the floor to the center of the box unless the AHJ requires otherwise. 9. Wall mounted horns and strobes shall be mounted at 80 inches to the bottom of the box above the finished floor.The candela rating is noted near the device on the drawings. 10. Ceiling mounted horns and strobes will be noted with a "C".The candela rating is noted near the device on the drawings. 11. All control cabinets and power supplies cabinets are to have tamper switches and be monitored by the fire alarm. 12. The HVAC Contractor is to mount the duct detectors, and wire the HVAC shutdown to the associated ADT supplied control module. ADT is to supply,wire and power the duct detectors. Duct detectors are to be installed in the Return duct and/or supply duct as required by local codes. 13. The JCPenney electrical contractor is to supply all required 120VAC to the fire alarm control panel and all power supplies on dedicated Circuit(s). The circuit(s) are to be locked and label "FIRE ALARM DO NOT TURN OFF". 14. The JCPenney electrical contractor is to supply all conduit stub ups, back boxes, power supply inter connection conduit required and any under ground conduit and wiring to outside devices. The under ground wire is to be THHW or equal. 15. The GC is to supply a 4"Plywood back board in the sprinkler room large enough to mount all controls, battery boxes and power supplies. 16. The JCPenney sprinkler contractor is to supply, install and adjust all sprinkler system supervisory switches. 17. Upon completion of the installation 2 built. one set is to be left on site in control panel. The other set is to be ,MS0046, Plano, TX 75014 Attn..: Cad sets of plans shall be marked up for as a locked cabinet at the fire alarm returned to ADT, 6501 Legacy Dr. Dept... Fire A(arm Legeno Symbol Qty Description Manufacture/Part Number Mounting Requirements 1 Fire Alarm Control Panel FireLite MS9600 W/DACT-UD Surface mounted enclosure provided Top 72' AFF conduit to ceiling FCP 1 Fire Alarm Annunciator' Alpha Keypad FireLite LCD -80F Single or double Gang, 4' square box 60' AFF conduit to ceiling FSA 6 Addressable Dual Monitor Module FireLite MDF300 4' square deep box MDF 13 Addressable Monitor Module FireLite MMF300, MMF301 4' square deep box MMF ®P 6 Smoke Detector Photo Electric FireLite SD355 Single Gang, 3.5" Octagon or 4' Sq. Box in the ceiling OR 0 Heat Detector R of' R 135 deg or- indicated Fire Lite H355R 3 1/4' Octagon box mounted in the ceiling 0 Manual Pull Station FireLite BG-12LX Deep Single Gang Box 48' AFF to Center, Conduit to ceiling P 14 Addressable Control Module FireLite CRF -300 4' square deep box CRF ®p 25 Duct Smoke Detector Photo Electric FireLite D350PL 1/2' Flex to 4' Square Box 51125 Remote indicator Test/Reset FireLite RTS451KEY Single Gang Box Conduit to ceiling 9Water 4 Flow Switch Supplied by others 1/2' FLex to Deep 4' square box Conduit to ceiling 9 Sprinkler Valve Tamper Switch Supplied by others 1/2' FLex to Deep 4- square box Conduit to ceiling _ _i 2 Air Pressure Switch Supplied by others 1/2' FLex to Deep 4' square box Conduit to ceiling S Signal Power Booster Altronix AL1002UL-ADA Surface mounted enclosure provided I op /2' AF I- conduit to ceiling PB 4 Strobe Candella Indicated System Sensor SW or SWH Multi Candella Single or double Gang, 4' square box 80' AFF to bottom of box 83 Ceiling Strobe Candella Indicated System Sensor SCW or SCWli Multi Candella single or double Gang, 4' square box Mounted to the ceiling C E: 12 Horn Strobe Candella Indicated System Sensor P2W or- P2WH Multi Candella Single or double Gang, 4' square box 80' AFF to bottom of box C 126 Ceiling Horn Strobe Candella Indicated System Sensor PC2W or PC2WH Multi Candella Single or double Gang, 4' square box Mounted to the Ceiling QOutdoor r£ Wp 1 Horn Strobe Candella Indicated System Sensor P2RK Multi Candella Single or double Gang, 4' square box 84' to 96' AFG to top of' box 1 Auxilary Power Supply Altronix AL4000LX Surface mounted enclosure provided Top 72' AFF conduit to ceiling PS R 2 Power Supervisory Relay A77 -716B 4' Square Box Conduit to ceiling 0 Isolator Module Firelite I300 4' square deep box ISO SLC Circuit ADT-454747ARE 16 Ga 2 Cond Shielded FPLP Annuciator Circuit ADT-454746ARE 18 Ga 6 Cond Shielded FPLP Power Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Notification Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Duct Detector Test Station ADT-474711ARE 18 Ga 4 Cond FPLP Device Wiring ADT-474711ARE 18 Ga 4 Cond FPLP (:..RIP G.SLILL O 0 I7 / POE I7 o O 0 Fire Alarm Device Locations 2nd FLoor IT IT F.DulnN,1CbELiY -U/ WOMENS FE PRO-PRATT O POE 0111,1/111 FINE JEWELRY NTWE SEPHORA I cm Cl , ,f I---116 I I i I , 1 I I ET OtS fit I SELL 0 SHOES a a I "'' t11a111ukra I I I I I I r 1 1 1 1 I i i 1 1 1 I I t l l l l SP1 E9 STOO( Hry,IID1Y 0 S a ❑/ IV= u,. m. ❑ L OP.L.FIS SILLS El a El 0 ❑ WOMENS APPAREL DRESSES ❑ .31 i I I i J I I I 1 I r naw ❑ .r. uP".,.Is J I,NORE / NEW MALL ENTRANCE ❑ O a IT O S 8 1,V Building Information Occupancy Type "M" Mercantile Number of stories 3 Sq Footage: 236,000. 1st fir: 78,000 2nd fir: 80,000 3rd f I r: 78,000 Sheet index 1 2 3 4 = 5 6 = 7 8 Cover sheet First Floor Area 1 = first Floor Area 2 Second Floor Area Second Floor Area Second Floor Area Third Floor Area 1 Third Floor Area 2 1 2 3 9 = Riser diagram 10 = Battery calculations Fire Alarm Device Locations 3rd Floor MENS SHOES r.IPPl CLO rIINo I4EN8 SPORTSWEAR ACCESSORIES ��alnllutnl►lilfl�l IDrnilJl IPA ,+CCE SSO HIES wove, NEW MALL ENTRANCE RI RI ®D ©D RI RI ®D COD RI RI OD OD ® RI RI RI ®D OD ®D ®D RI RI RI RI ©p OD OD OD PENTHOUSE ON ROOF IS NOT TO SCALE DIMENSIONS WERE TAKEN FROM AN OVERHEAD VIEW OF THE SITE PLAN FLI_-- - - 1.1 0 1105 'hi�.ho ut CCtorrleents !!�� Ai4 I d Par The i2ta c;+cid Letter I nose plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance ':v ith current city standards. Acceptance is euhi,,ct to errors and a ornissiona which do riot authorize vio`:atic. of adopted -,1.ail-- 8r^s and ordinances. The re:.pcnsibili ; for the !(q� .:x;i of de°jigi7 re:,,t`, iut li',/ cairn me designer. 1 A.....i:.,t .Is. ,.,I +osis or ; L,- .cn<, P.) t'rr- drawings atter thi t l::' I.blii void cri:-, ,ltcceprance rind will rr.'ouire a resub4ln t rii of r evisr:d drawings for subsequent approval. SCALE = NTS TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE N O . JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972)-431-1275 FAX: (972)-431-3203 Southcenter Seattle, WA Cover Page Scale: Designer: 1/11/2008 BW Drawn By: Checked: JCP Prints: REVISIONS: BY REV. DATE NOTES: DLJ DW 1 1/16/2008 Updated per JCP Rev 1 dated 1/11/2008 2 2/14/2008 Updated per JCP Rev 2 dated 1/31/2008 DLJ DLJ 3 4 DW 5 Updated per Walkthrough. Removed Pull, added 3/6/2008 Riser Devices. Added Duct Detectors per Welkthrough. Added equipment to release door holders. 4/25/2008 Added relays to release roll -up gates at mall. Elevators not capable of J recall, equipment removed. Revised per JCP Rev 4 dated 6/13/2008. Revised 6/19/2008 one FltUng Room, updated mall entrance and Door Holders 6 6/19/2008 Replaced HVAC units in salon and office area Replaced duct detectors on those units DDEC 120 Tuk ilia Fire I i a.2, 4,1561 I 1 SHEET NO: 1 OF 10 Final acceptance is subject to field test and inspection b‘ The Tukwila Fire Prevention Bureau. / , pate: � `� Q ?� By: ..(// TUKilr1LA FIRE DEPARTML1114 Please call: 575-4407 and give this job and exact address for shut' down or restoration approval; NOTICE A completed, signed, Tukwila Fire. Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. STAIRS SECURITY OFFICE 30CD SPRINKLE ROOM NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. ANTE ROOM OPTICAL OFFICE STAIRS OFFICE MACHINE ROOM 8'-0" CEILING 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. OFFICE ELEVATOR MACHINE ROOM 115CD C PB -2 CIR-1A EOL 75CD T -• -1)0:10 ._ MODULE TO TURN LIGHTS ON DURING A FIRE ALARM THROUGH EMS 30CD WINDOW 4'-7" HIGH PARTITION 8' 4 0 8' SCALE 1/8"=1'-0" I.I I LL,: FIRE SYSTEM DEVICE LOCATIONS IL NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972)-431-1275 FAX: (972)-431-3203 Building Key: ELEVATOR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. r aA GE ELE ', OR L_ 8T -D" RBL INTERVIEW • 30CD 42"I HIGH PARTITION 8'-11" CEILING JANITOR CLOSET CONCRETE FLOOR INTIMATE RECEPTION AREA LOUNGE 30CD CONFERENCE ROOM TRAINING ROOM 177CD SIC PB -2 CIR-1B COL BATH SHOP QUADVIIRAP INTIMATE APPAREL SALES SUPPORT MANAGER SALES SUPPORT MANAGER '71770 Southeenter PB -2 CIR-2A CDL INTIMATE BUSINESS PLANNING MANAGER BUSINESS PLANNING MANAGER STORE MANAGER Scale: Date: Designer: Drawn By: Checked: JCP Prints: ELECTRICAL PANELS MONEY ROOM VAULT BY Seattle, WA 98188 0 0 t=a rn Alarm Plans a) • 1/8"=V-0" 1/11/2008 BW DLJ 3/7/2003 REVISIONS: REV. DATE - -- 30CD 133'I C NOTES: Updated per JCP Rev 1 1 1/16/2008 dated 1/11/2008. No Prints This Floor PB -1 CIR-4B CDL PB -1 CIR-4A CDL DLJ Updated per JCP Rev 2 2/14/2008 dated 1/31/2008 No Prints This Floor Updated per Walkthmugh. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. 3 3/6/2008 4 4/25/2008 5 MO PB -1 CIR-3A CDL MATERNITY 30CD C ACCOUNTING OFFICE PB -1 CIR-3B CDL OFFICE UP TO 2ND FLOOR ELEVATOR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR TELEPHONE ROOM SECONDARY PHONE TRUNK 6/19/2008 6 6/19/2008 Added equipment to release door holders. Added relays to release roll -up gates at mall. Elevators not capable of recall, equipment removed. Revised per JCP Rev 4 dated 6/13/2008. No New Prints for this floor. Replaced HVAC units In salon and office area Replaced duct detectors on those units SHEET \O: 2 OF 10 Air Pressure System PIV System Outside Dry ELEVATOR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. :D /\ SPRINKLER ROOM STOCK SZ30CD 30CD STOCK 30CD YC STAIRS SPRINKLER VALVE ROOM 30CD 30CD C 75CD C V 177CD C PB -i CIR-1A EEL J J J TO PB V 177CD C d / / / / / / / / / / / / / / ELECTRIC PANELS I I T I 115CD \ / I HOME BEDDING I ) UP TO ,117,0" PAR FROM F IRS FL 74 75CD C I TO PB _J I 177CD C I HOUSEWARES I I I I I TO PB V 177CD / QUADWRAP I I I HOME ACCESSORIES L. _- -..� PB -i CIR-2B EEL V 177CD LUGGAGE I I V177 C ...AO Corm 0 � .JEL J • CD FURNITURE .4 riwarAr TO PB 75CD C..- I 75CD C S7177CD '0' C PB -i C IR -2A EEL CU/S'TOM DECOR EXIST. ELEC. CLOSET N 5\ 0 v 75CD --4C / r / ////// 12'-0" C.H. ///// 10'-0" C.H. ///////////// 75CD //// /rr//// CD --1;0;1 I STORAGE PB -1 CIR-1B EOL 30CD C STOCK L - - - V 30CD C I / / / / / / / / / / / / I 75CD FURNITURE J 7'a" C.H. NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. Building Key: 8' 4 0 8' SCALE 1/8"=1'-0" "IT LE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972)-431-1275 FAX: (972)-431-3203 14. SI c Southcenter co co Seattle, WA O CD SI Alarm Plans Scale: Date: 1/8"=1'-0" 1/11/2008 Designer: BW Drawn By: DLJ Checked: JCP Prints: 3/7/2003 REVISIONS: BY REV. DATE NOTES: DLJ DLJ 1 1 /16/2008 Updated s ed 1%11 2008 Rev 1 No Prints This Floor -- -----Updated per JCP Rev 2 2 2/14/2008 dated 1/31/2008 No Prints This Floor DU 3 3/6/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. DU 4 4/25/2008 Added equipment to release door holders. Added relays to release roll -up gates at mall. Elevators not capable of recall, equipment removed. DU 5 6/19/2008 Revised per .ICP Rev 4 dated 6/13/2008. No New Prints for this foor. MO 6 6/19/2008 Replaced HVAC units In salon and office area Replaced duct detectors on those units SHEET \ 3 OF 10 0: PB -3 CIR-3A EEL MATCHLINE MATCHLINE Ct LL rn rr STAIRS STAIRS STO 30C C D v30CD -WI- • • - • • WOMEN 14D - EXISTING 9 NEW FITTING ROOMS 30CD ,-0,�CHT -- :WIC J I , j 15CD 'C J 15CD -- 30CD C FIRE EXIT OFFICE STAIRS STOCK ;W 75CD C I I II � I_i V �V FSA CEILING 10'-0" --Y.- \ \ '- -{ TO PB 1 TO FCP FACP CIR-3 EOL W!W z!z _J ! .J =I• = � < WP V 110CD !I I;o:I I EXISTING PIPE CH/ISE C TO FCP TO PB I ELEVATOR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. I r \%' 177CD C L- I I I 177CD / I 177CD I I I I FINE JEWELRY 1 L. V 177CD C PB -3 CIR-2B COL /) I 177CD ----�TOPB I I .4-._._. s I TO PB \7177CD C / I I TO PB 177CD C PETITES E L. I I UP DOR E S v A[i 0 S UP FRO MB SEKNI T WOMENS ACCE: . NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. Building Key: 8' 4 0 8' SCALE 1/8"=1'-0" TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972)-431-1275 FAX: (972)-431-3203 C A Alarm Plans - 2nd Floor N .- Scale: 1/8"=1'-0" Date: 1/11/2008 Designer: BW Drawn By:__DU __-- Checked: JCP Prints: 12/5/2007 REVISIONS: BY REV. DLJ 1 DLJ 2 DATE NOTES: 1/16/2008 Updated per JCP Rev 1 dated 1/11/2008 2/14/2008 Updated per JCP Rev 2 dated 1/31/2008 DLJ 3 Updated per Walkthrough. Removed Pull, added 3/6/2008 Riser Devices. Added Duct Detectors per Wal kthrough. DLJ 4 Added equipment to release door holders. 4/25/2008 Added relays to release roll -up gates at mall. Elevators not capable of recall, equipment removed. DLJ 5 Revised per JCP Rev 4 dated 6/13/2008. Revised 6/19/2008 one Fitting Room, updated mall entrance and Door Holders MO 6 Replaced HVAC units In 6/19/2008 salon and office area Replaced duct detectors on those units SHEET \O: 4 OF 10 NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. MATCHLINE MATCHLINE .1T T 8' 4 0 8' SCALE 1/8"=1'-0" TIT FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972)-431-1275 FAX: (972)-431-3203 Building Key: I I I I I TO PB V 177CD PB -3 C I R -2A CDL 1 177CD C L. _ 7177CD OUTERWEAR 1'41 C PB -2 CIR-4B CDL SHOES I I I I I I L TO PS --HCRFI FIRE ALARM RELAY CONNECTED ! i TO DOOR HOLDERS TO RELEASE DOORS DURING A FIRE ALARM. ELEVATOR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. FIRE ALARM RELAY CONNECTED ` TO DOOR HOLDERS TO RELEASE X A\ DOORS DURING A FIRE ALARM. ' FROM 1ST FLOOR 730CD —1 !— LJ L EXISTING ELECTRICAL PANELS F - FREIGHT ELEVATOR I i TEl PB L L. 75CD 30CD C L _ PB -3 CIR-1A EDL v 30CD UP UP L_ C s V 30CD L 30CD LCD 30CD SHOES STOCK ALL FIRE ALARM WIRE BELOW MEZZANINE TO BE IN CONDUIT V' 30CD J W a w 1t'IC W i LL! Z I Z _f =I= 010 I— H - <i < Southcenter C FREIGHT ELEVATOR Scale: UPPER LEVEL SHOE STOCK TO PB Drawn By: PB -3 CIR-1B CDL v 30CD 125172BA DN 3125172 BA '//7i///f///P 730LD C 2125172BA 1236728A // DN /// Checked: WA 98188 2nd Floor Alarm Plans (1) 4-4 1/8"=1'-0" 1/11/2008 BW DLJ JCP Prints: 12/5/2007 30 ll L- - - - _ - - - - _ - v 30CD C KIDS SHOE STOCK LCD 30CD S7 30CD - 1 I 30CE C J L_ FREIGHT ELEVATOR REVISIONS: BY REV. DLJ 1 DLJ 2 DLJ ( 3 DATE NOTES: 1/16/2008 2/14/2008 3/6/2008 DLJ 4 4/25/2008 DLJ 5 6/19/2008 MO 6 6/19/2008 Updated per JCP Rev 1 dated 1/11/2008 Updated per JCP Rev 2 dated 1/31/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. Added equipment to release door holders. Added relays to release roll -up gates at mall. Elevators not capable of I recall, equipment removed. Revisedper JCP Rev 4 dated 6/13/2008. Revised one Fitting Room, updated mall entrance and Door Holders Replaced HVAC units In salon and office area Replaced duct detectors on those units SHEET \O: 5 OF 10 D ! WOMENS FR rrr4 PIPE CHIISE I— TO PB CLOS TOC D IC FITTING ROOM 1O' -O" CH STAIRS ELEVATOR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. T L_ I STORAGE i \I P�TITES j I I CO 177CD C I 0. 1 E S CA D 1VN 10 BAi ENE`! DOA FRI a RID IAA -.m-- I• T :NSE ACCESS I z c7 177CD x N STARS I I I 30CD I z\ ADD 3 NEW WALL HORN/STROBES I 0 30CD - -q- i 30C I ' MOVE P2W-1 10 TO NEW ROOM AND CHANGE TO P2W-30 -I I I a I wwww I 177CD lJ 1 RECEIVING I gam CONCRETE (TYPICAL JUL; ti I I '13CD;\ GUI COMPACTOR TRUCK RAMP DOWN III CONTAINER 0 30CD \\ WOMENS SIZES I Wilk ARP pr POS / TO PB I DRESSES — POS V177CD C L 30CD r x WIW ZIZ PB -2 C IR -4A ESL IX FIRE ALARM RELAY CONNECTED TO SECURITY GATE TO RELEASE GATE DURING A FIRE ALARM. N PRO -RATE I WOMENS APPAREL t177CD PB -2 CIR-3B EDL 1 I I I N JUNIORS V 177C I NB 30CD C FITTING R'OMS IVI 177CD ho 15CD PB -2 CIR'-2B EEL RUN ANOTHER CIRCUIT FROM P85, CIR 2B. I TO PB 15CD rI V 75C D C� I I I I L Fi PB -5 CIR-2B EEL IC OCD 7 C Cr) z W 2 0 111.2.1.1.110011310113 ELECTRIC PANELS - 1 `7 75CD HOSIERY STOCKROOM PB -2 CIR-3A EEL WOMENS FR Ies, rl--+n I rv-r•iL-- r n -I STAIRS STAIRS )-J NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. Building Key: 8' 4 0 8' SCALE 1/8"=1'-0" TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972)-431-1275 FAX: (972)-431-3203 cr.) U Scale: 7Y Southcenter WA 98188 4.7 Alarm Plans — 2nd Floor N .- 1/8"=1'-0" Date: 1/11/2008 Designer: BW Drawn By: DLJ Checked: JCP Prints: 12/5/2007 REVISIONS: BY REV. DATE NOTES: DLJ 1 1/16/2008 Updated per JCP Rev.' dated 1/11/2008 DLJ 2 2/14/2008 Updated per JCP Rev 2 dated 1/31/2008 DLJ DLJ 3 3/6/2008 4 4/25/2008 Updated per Welkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. Added equipment to release door holders. Added relays to release roll -up gates at mall. Elevators not capable of recall, equipment removed. DLJ MO 5 6/19/2008 6 6/19/2008 Revised per JCP Rev 4 dated 6/13/2008. Revised one Fitting Room, updated mall entrance and Door Holders Replaced HVAC units in salon and office area Replaced duct detectors on those units SHEET NO: 6 OE 10 NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT CLOSET STAIRS OFFICE HILDRENS FITTING ROOMS _ 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. PB -5 CIR-1A EEL LOCATE HORN STROBES IN STOCK AREAS FOR BEST COVERAGE AROUND SHELVING / 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. 15CD —I,aFC ATHLETIC SHOES STAIRS 7 1 I I y 30CD /5CD- - - - - -.. _ IMP C — — MEN'S SHOES 8' 4 0 8' SCALE 1/8"=1'-0" TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE N O JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972)-431-1275 FAX: (972)-431-3203 Building Key: ELEVATOR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. PAS ELE PB -5 CIR-BA EEL REAR-ANGE STROBES IN LOUNGE AND RESTROOMS. GIRLS CHILE RENS �7177C ,a C INFANTS PB -4 CIR-4B EEL / / / / / / / Southeenter O O / //////// / / / / / / / / / V/Y/,i//i Scale: Date: Designer: Drawn By: Checked: JCP Prints: Seattle, WA 3rd Floor Fire Alarm Plans 1/8"=1'-0" 1/11/2008 BW DLJ 12/5/2007 REVISIONS: BY REV. DATE NOTES: DLJ 1 1 /16/2008 Updated per JCP Rev 1 dated 1/11/2008 DLJ 2 2/14/2008 Updated per JCP Rev -2— dated 1/31/2008 ( I FITTING ROOMS / C/ DU DW MO Updated per Walkthrough. Removed Pull, added 3 3/6/2008 Riser Devices. Added Duct Detectors per Walkthrough. Added equipment to release door holders. 4 4/25/2008 Added relays to release roll -up gates at mall. Elevators not capable of recall, equipment removed. 5 I 6/19/2008 ' Revised per JCP Rev 4 dated 6/13/2008. Revised one Fitting Room, updated mall entrance Replaced HVAC units In 6 16/19/2008 salon and office area Replaced duct detectors on those units ATHLETIC APPAREL 8'-10" CEILING PORTRAIT STUDIO UP TO PENTHOUSE PLACE 30ccl STROBES IN STUDIOS AND/OR CHANGING ROOMS 30CD 30CD 30CD --1°C PB -4 CIR-3B jEOL ELEVATOR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. /5CD i�ING ROOMS FREIGHr ELEVATOR PB -4 CIR-3A EEL SHEET \O: 7 OF 10 2i2 7 30CD I I, TO FACP TO PS STAIRS TO PB 75CD C ELEVATOR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE r ELEVATOR UPGRADE. I L J TQC J BOILER CONDEMNED ALTERATIONS FREIG ELEV FITTING ROOMS 75CD C 7 177CD I MENS CLOTHING I /7/7/7 / ,/ , / 7/7/ / l ' / / / / / 115CD MENS I1 J I .77// / FITTING ROOMS 11.5CD L- 30CD C / — I / 7/// 0177CD I I I �7177CD C 75CD C PB -3 CIR-3B EOL I I L'J TO PB 177CD "al C I ACCESSORIES 75CD C I TO PB 75CD _ _ 75CD TO PB A110CD _. J L - _. — NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. Building Key: TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972)-431-1275 FAX: (972)-431-3203 I I I I 75CD PB -4 CIR-2B EOL I ar / FITTING ROOMS / 7/ CRF J I YOUNG MENS t 177CD bC PB -4 CIR-2A EOL FIRE ALARM RELA" CONNECTED TO SECURITY GATE TO RELEASE GATE DURING A FIRE ALARM. -J i J -r 1 T J. I I I L_ I C PB -4 CIR-1B EOL PB -4 CIR-lA EOL I I I 75CD C Scale: Designer: Drawn By: Checked: JCP Prints: Southcenter 8'-1"I CEILING STOCK o 115CDI ft r30CD C L _ 8'-12" CEILING LL 30CD r 30CD I 75CD_ C. -..— ALL RELAYS FOR HVAC SHUTDOWN LOCATED IN ONE AREA I L I RELOCATED ELECTRICAL PANELS z PB -3 CIR-4A EOL 110CD FROM FREIGHT ELEVATOR L F 75CD I PB -3 CIR-40 EOL I REPLACE EXISTING SMOKE DETECTOR. 75CD BY Seattle, WA 98188 3rd Floor Alarm Plans — Q) •� 1/8"=V-0" 1/11/2008 BW DLJ 12/5/2007 REVISIONS: REV. I DATE NOTES: DLJ 1 I 1/16/2008 DU DU Updated per JCP Rev 1 dated 1/11/2008 2 I 2/14/2008 dated 1/31/2008 Updated per JCP Rev 2 3 I 3/6/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Welkthrough. Added equipment to release door holders. DU 4 14/25/2008 Added relays to release roll -up gates at mall. Elevators not capable of _I. recall, equipment removed. DLJ 5 16/19/2008 Revised per JCP Rev 4 dated 6/13/2008. Revised one Fitting Room, updated mall entrance MO 6 I 6/19/2008 Replaced HVAC units in salon and office area Replaced duct detectors on those units SHEET \0: 8 OF 10 ffL Cir 4 (1)2#14 FPLP Cir 3 (1)2#14 FPLP Cir 2 (1)2#14 FPLP Cir 1 (1)2#14 FPLP Dedicated 120 VAC 20 Amp Circuit( Locked) FireLite MS9600 DACT-UD SLC L000 Style 4 (1)2#16 FPLP SLC Loop Style 4 (1)2#16 FPLP CRF ©D CRF CRF HVAC r5i -*" • T - .*. Shut Down IL it ii 11 it it ii it II it it HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC Shut Shut Shut Shut Shut Shut Shut Shut Shut Shut Down Down Down Down Down Down Down Down Down Down YY Box Tappers Control Panel Phone Line 1 Phone Line 2 FSA FireLite BB -26F Battery 12V25AH Battery 12V25AH (1)4#18 FPLP FireLite BB -26F System Documentation As Built Drawings Y Y Ht4- Immo m ® ® ® M F MDF I I Box Tanpers PB -1 PB -2 PB -3 PB -4 PB -5 PS Box Tampers Box Tappers Y EMS Light Control HVAC Shut Down CIA WA 0 Security Gate Release A\ \‘Vit,„ Door Holder Release ALtron c AL4000LX Duct Detector Power a a, rFfL kalcrffLkk Cir 4A (1) #14/2 Cir 3A (1) #14/2 Cir 2A (1) #14/2 Gir 1A (1) #14/2 Cir 4B [ rt IRIC r (1) #14/2 Cir 38 (1) #14/2 Cir 28 (1) #14/2 Cir 1B PL aL )ffic )ac (1) #14/2 Altronix 1002ULADA #1 Battery Gro mnd aka Dedicated 120 VAC 20 Amp Circuit(Locked) Cir 4A ac Pt Pt Pts PtPtPtfriL NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. 5. HORNS AND STROBES ARE TO BE MOUNTED 80" ABOVE THE FINISHED FLOOR TO BOTTOM OF UNIT OR 6" DOWN FROM THE CEILING TO THE TOP OF THE UNIT, WHICHEVER IS LOWER. UNITS NOTED WITH A "C" ARE TO BE CEILING MOUNTED. (1) #14/2 Cir 3A (1) *14/2 Cir 2A (1) #14/2 Cir 1A 6. MANUAL PULL STATIONS ARE TO BE MOUNTED 48" ABOVE THE FLOOR TO THE TOP OF THE UNIT. 7. ALL DEVICES ARE TO BE MOUNTED ON BACK BOXES. 8. WIRE IS TO BE IN CONDUIT TO THE CEILING OR FISHED IN WALLS. 9. CONNECTIONS TO THE POWER SERVICE SHALL BE ON A DEDICATED BRANCH CIRCUIT. THE CIRCUIT AND CONNECTIONS SHALL BE MECHANICALLY PROTECTED THE POWER CIRCUIT SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL". THE LOCATION OF THE DISCONNECTING MEANS SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. (I) #14/2 Cir 48 (1) #14/2 it 38 0 0 0 0 0 (1) #14/2 (1)C r 2B n Itt1 n aa n n Cir 18 (1) #14/2 Altronix 1002ULADA #2 Battery Gro�nd Pt Pt Pt Pt Pt Dedicated 120 VAC 20 Amp Circuit(Locked) Ittl Ittl Ittl Ixtl Cir 4A (1) #14/2 Cir 3A (1) *14/2 Cir 2A (1) *14/2 ' ic ic c C L ' ic r 1A (1)Gi#14/2 Cir 4B I'x1 I>71 I)tl Ittl (1) *14/2 Cir 3B (1) *14/2 Cir 2B L L L L L L )ffifl C (1) #14/2 Cir 18 (1) #14/2 Altronix 1002ULADA #3 Battery Gro�nd Tire AJarrn L_ecenc Dedicated 120 VAC 20 Amp Circuit(Locked) Symbol Qty Description Manufacture/Part Number Mounting Requirements Duct Smoke Power Wiring 1 Fire Alarm Control Panel FireLite MS9600 W/DACT-UD Surface mounted enclosure provided Top 72" AFF conduit to ceiling FCP WJ1055 FC1010 1 Fire Alarm Annunciator Alpha Keypad FireLite LCD -80F Single or double Gang, 4" square box 60" AFF conduit to ceiling FSA WJ1088 LC150 SEALANT 6 Addressable Dual Monitor Module FireLite MDF300 4" square deep box MDF PVC CONDUIT 2" AND SMALLER CAJ2031 13 Addressable Monitor Module FireLite MMF300, MMF301 4' square deep box MMF CAJ2038 ®P 6 Smoke Detector Photo Electric FireLite SD355 Single Gang, 3.5" Octagon or 4' Sq. Box in the ceiling ®R 0 Heat Detector R of' R 135 deg or indicated Fire Lite H355R 3 1/4' Octagon box mounted in the ceiling n 0 Manual Pull Station FireLite BG-12LX Deep Single Gang Box 48' AFF to Center, Conduit to ceiling CAJ4029 16 Addressable Control Module FireLite CRF -300 4' square deep box CRF CAJ4020 ®D 25 Duct Smoke Detector Photo Electric FireLite D350PL 1/2" Flex to 4" Square Box 25 Remote indicator Test/Reset FireLite RTS451KEY Single Gang Box Conduit to ceiling RI 9 a 4 Water Flow Switch Supplied by others 1/2" FLex to Deep 4' square box Conduit to ceiling (Q 7 9 Sprinkler Valve Tamper Switch Supplied by others 1/2" FLex to Deep 4" square box Conduit to ceiling FC3015 2 Air Pressure Switch Supplied by others 1/2" FLex to Deep 4" square box Conduit to ceiling 5 Signal Power Booster Altronix AL1002UL-ADA Surface mounted enclosure provided Top 72" AFF conduit to ceiling PB 4 Strobe Candella Indicated System Sensor SW or SWH Multi Candella Single or double Gang, 4' square box 80' AFF to bottom of box ;c( 83 Ceiling Strobe Candella Indicated System Sensor SCW or SCWH Multi Candella Single or double Gang, 4' square box Mounted to the ceiling C V 12 Horn Strobe Candella Indicated System Sensor P2W or P2WH Multi Candella Single or double Gang, 4' square box 80' AFF to bottom of box c( V 126 Ceiling Horn Strobe Candella Indicated System Sensor PC2W or PC2WH Multi Candella Single or double Gang, 4" square box Mounted to the Ceiling alc VOutdoor :ct Wp 1 Horn Strobe Candella Indicated System Sensor P2RK Multi Candella Single or double Gang, 4' square box 84' to 96' AFG to top of box 1 Auxilary Power Supply Altronix AL4000LX Surface mounted enclosure provided Top 72' AFF conduit to ceiling PS IT] 2 Power Supervisory Relay A77 -716B 4' Square Box Conduit to ceiling 0 Isolator Module Firelite I300 4' square deep box ISO SLC Circuit ADT-454747ARE 16 Ga 2 Cond Shielded FPLP Annuciator Circuit ADT-454746ARE 18 Ga 6 Cond Shielded FPLP Power Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Notification Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Duct Detector Test Station ADT-474711ARE 18 Ga 4 Cond FPLP Device Wiring ADT-474711ARE 18 Ga 4 Cond FPLP Pt Pt Pt Pt Cir 4A (1) #14/2 Cir 3A (1) #14/2 C C C C (1)#14/2 L t i C i C C (1) #14/2 Supplied, Installed & Wired by JC Supplied, Installed & Wired by JCI 24VDC to Next JCI Relay or superviory relay. SLCLoop To next device Cir 49 (1) #14/2 )fft PL PL Cir 3B I>xIL k k I:k (1) *14/2 Cir 2B at k i>x k (1) #14/2 Gir. 1B (1) #14/2 Altronix 1002ULADA #4 Battery Ground Dedicated 120 VAC 20 Amp Circuit(Locked) Wire Legeno Cir 4A (1) *14/2 Cir 3A (1) #14/2 CC C t Cir 2A (1) *14/2 5157L 5LI>x g i�( Cir 1A (1) #14/2 ------------- -- - -- - -- Notification Wiring - Fire Alarm Device Wiring, - .- Duct Smoke Power Wiring FIRE RATED PENETRATION SCHEDULE TYPE OF PENETRATION CONCRETE OR MASONARY GYPSUM BOARD/FRAME "SPECSEAL PRODUCTS FLOORS UL SYSTEM # WALLS UL SYSTEM # FLOORS UL SYSTEM # WALLS UL SYSTEM # METAL CONDUITS ANY SIZE CAJ1079 WJ1055 FC1010 WJ1049 SSS100 SEALANT CAJ1213 CAJ1213 WJ1088 LC150 SEALANT CAJ1198 CAJ1198 WL1062 PENS00 SILICONE PVC CONDUIT 2" AND SMALLER CAJ2031 WJ2018 FC2032 WL2093 SSS100 SEALANT PVC CONDUITS 2" THRU 4" CAJ2038 CAJ2038 FC2033 FC2029 FIRESTOP COLLAR CAJ2045 CAJ2045 FIRESTOP COLLAR CAJ2124 CAJ2124 FC2033 WL2059 WRAP STRIPS CABLE TRAY STEEL OR ALUMINUM CAJ4029 CAJ4029 WL4008 FIRESTOP PILLOWS CAJ4020 CAJ4020 FIRESTOP MORTAR CAJ4009 WL4005 SSS100 SEALANT ELECTRICAL BUS DUCT CAJ6009 CAJ6009 FIRESTOP MORTAR 1 CAJ6008 CAJ6008 WL6D01 SSS100 SEALANT MAX. 3" CABLE BUNDLES CAJ3133 WJ3022 FC3015 WL3D76 SSS100 SEALANT NOTES; 1. ALL U.L. USTED SYSTEMS SHOWN ABOVE ARE BASED ON PROVIDING A 1 & 2 HOUR RATED FIRESTOP. WHERE 3 HOUR RATING IS REQUIRED, CONTACT FIRESTOP PRODUCT MANUFACTURER FOR DESIGN MODIFICATIONS. 2. ALL U.L. USTED SYSTEMS SHOWN ABOVE ARE BASED ON "SpecSeal Firestop" PRODUCTS FROM SPECIFIED TECHNOLOGIES, INC. OR APPROVED EQUAL PRODUCTS FROM "3-M" OR HILTI, INC. Devices mounted within 3' of starter motor NIJ/C/NC Interface Relay „Supplied by ADT Installed & Wired BY JCI CRF300 SLC + Red held wire SLC - Black Splice and NO/C/NC insulate. ----"--SLC Loop In & Out (2)21116 FPLP Shielded Note: All devices must be installed, connected and programed into the fire alram system. Prior to connecting the 24VDC to the power supply in order to prevent the accidental shutdown of all HVAC systems. Cir 4B (1) #14/2 Cir 38 (1) #14/2 Cir 2B i ( '"'t (1) #14/2 Cir 1 (1) #14/2 Altronix 1002ULADA #5 Battery Gro�nd Duct work Duct detector Supplied & wired by ADT Installed by JCI SLC Loop From FCP or previous device 24VDC from Power supply or previous device Red + Black _ Dedicated 120 VAC 20 Amp Circuit(Locked) SCALE = NTS TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972)-431-1275 FAX: (972)-431-3203 Southcenter 0 C\2 Seattle, WA Diagram & Battery Calcs cn Scale: Date: NTS 1/11/2008 Designer: BW Drawn By: DLJ Checked: JCP Prints: REVISIONS: BY REV. DATE I NOTES: DLJ I 1 fi DLJ 1 2 1/16/2008datedTUpdated1/ p12 22/14/200 r JCP Rev 1 8 � - U- pdated per JCP Rev 2 dated 1/31/2008 DLJ 3 DU 4 DLJ 5 Updated per Walkthrough. Removed Pull, added 3/6/2008 Riser Devices. Added Duct Detectors per Welkthrough. 7 Added equipment to release door holders. Added relays to release roll -up gates at mall. Elevators not capable of recall, equipment removed. 4/25/2008 Revised per JCP Rev 4 dated 6/13/2008. Revised 6/19/2008 i one Fitting Room, updated mall entrance and Door Holders MO 6 6/19/2008 Replaced HVAC units in salon and office area Replaced duct detectors on those units SHEET NO: 9 OF 10 Part Number AL400U.X Standby Battery Calculations Altronix AL4000LX JCPenney Seattle, WA 98188 Description Quantity Power Supply 4A @12 or 3A (dJ 24V[ 1 Standby Current Alarm Current Per Device AI Devices Per Device All Devices 0.060 0.060 0.060 0.060 Auxiliary devices Maxm.im3 Amps A77-7166 Pow er Supervisory Relay Total Aux current 2 0.019 0.038 0.000 Max 3 Amps 0.098 Standby Hours Standby Battery Draw Standby Amp Firs 24 0.098 2.352 Alarm Current Alarm Current 5 Mn 0.098 0.008 Battery Size Required with 5 Mn. AlarmTirne and 20% Reserve 2.832 !Battery Size Supplied 7 A.H. 0.019 0.038 0.000 Alarm 0.098 Sequence of Operation Standard Fire Alarm Zoning 0.000 0.000 ii 0 In be `� U1 q id el FireLite MS9600 Transmits alarm signal to UL listed manitorig center Reporting Zone # Address Number 1 Deuce Software Zone Software Zone Software Zone Software Zone Software Zone All Devices NAC #1 System sensor Sync 1 2 DACT UD Dual Line Dialer 1 0.100000 0.100000 0.132000 0.132000 NAC #2 ;System sensor Sync 1 2 SD355 Stroke Detector Photo 6 0.000300 0.001800 0.000300 0.001800 NAC #3 ; System sensor Sync 1 2 M7F 300 Monitor Module Dual input 6 0.000750 0.004500 0.000750 0.004500 NAC #4 i System sensor Sync 1 2 MM -301 Montior Module Smal 8 0.000375 0.003000 0.000375 0.003000 Relay #1 Alarm 1 2 D350FL Duct Stroke Detector 25 0.000300 0.007500 0.000300 0.007500 Relay #2 Trouble 4 0.200000 x Voltage Drop = 2 " Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 0.000000 0.000000 Relay #3 ' Super isory 3 0.591 x Signal Circuits Standby Amp Hrs 5.400 Loop #1 Module Addresses 0.000 Alarm Current Circuit Device Quantity 160 1 Box Tampers Control 3 0.175 0.000 x ' 161 2 Box Tampers Battery Box 3 0.000 x x 163 4 Water flow #1 1 0.000 Circuit 2 AL1002UL-ADA-J 164 5 Sprinkler Tamper Switch #1 3 Circuit 1A Circuit 2A Circuit 3A 0.000 Max Wire Run Distance For AWG 14 668 792 Smoke detectors 165 6 Water flow #2 1 Circuit 1B Circuit 2B Circuit 3B 0.000 Total2 Maxitrum2.5 Amps 166 7 Sprinkler Tamper Switch #2 3 0.212 0.212 x Standby Hours 60 167 8 ' Water flow #3 1 Standby Arrp Firs 5.400 0.000 x x 168 9 Sprinkler Tamper Switch #3 3 0.212 Circuit 4 169 10 Sprinkler Tamper Switch #4 3 I Battery Ste Supplied 18 A.H. 0.000 170 11 Sprinkler Tamper Switch #5 3 0.000 Total4 Maximum2.5 Arrps 171 12 Sprinkler Tamper Switch #6 3 0.212 Circuit 1 Circuit 2 172 13 , Dry Water flow #1 1 3073 Actual Wire run Distance 173 14 Dry Sprinkler Tamper Switch #1 3 0.130 Voltage Drop = 2 *Wre Run Distance * 3.07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 174 15 ' Air Pressure Switch High 3 Standby Hours 60 175 16 Air Pressure Switch Low 1 176 17 a Outside PIV #1 3 177 18 Outside PIV #2 3 Alarm Current 5 Mn 0.067 178 19 Box Tampers Power Supply 3 179 20 1 Box Tampers Power Expander#1 3 and 20% Reserve 19.288 _ 180 21 Box Tampers Power Expander #2 3 !Battery Size Supplied 25 A.H. 181 22 , Box Tampers Power Expander #3 3 182 23 Box Tampers Power Expander #4 3 183 24 Box Tampers Power Expander #5 3 228 69 Security Gate Release 1 2 229 70 Security Gate Release 1 2 230 71 ; Door Holders Release 1 2 233 74 EMS Light control 1 2 252 93 HVAC #1 Shutdown 41 253 94 HVAC #2 Shutdown 42 254 95 !HVAC #3 Shutdown 43 255 96 HVAC #4 Shutdown 44 256 97 i HVAC #5 Shutdown 45 257 98y HVAC #6 Shutdown 46 258 99 ' HVAC #7 Shutdown 47 259 100 HVAC #8 Shutdown 48 . 260 101 HVAC #9 Shutdown 49 261 102 HVAC #10 Shutdown 50 262 103 i HVAC #11 Shutdown 51 263 104 HVAC #12 Shutdown 52 272 113 EOL Power SuperHsion MMF 61 273 114 1 EOL Power Supervision MMF 62 Detector Addresses 001 1 i Smoke Detector at panel 2 002 2 ' Smoke Detector at Penthouse 2 003 3 Smoke Detector at Door Holders 2 004 4 ; Smoke Detector at Door Holders 2 005 5 Smoke Detector at Door Holders 2 006 6 Smoke Detector at Door Holders 2 021 21 AHU #1 Supply Duct Detector 3 41 022 22 'AHU #1 Return Duct Detector 3 41 023 23 AHU #2 Supply Duct Detector 3 42 024 24 AHU #2 Return Duct Detector 3 42 025 25 I AHU #3 Supply Duct Detector 3 43 026 26 ' AHU #3 Return Duct Detector 3 43 027 27 , AHU #4 Supply Duct Detector 3 44 028 28 AHU #4 Return Duct Detector 3 44 029 29 AHU #5 Supply Duct Detector 3 45 030 30 AHU #5 Return Duct Detector 3 45 031 31 AHU #6 Supply Duct Detector 3 46 032 32 AHU #6 Return Duct Detector 3 46 033 33 AHU #7 Supply Duct Detector 3 47 034 34 AHU #7 Return Duct Detector 3 47 035 35 AHU #8 Supply Duct Detector 3 48 036 36 AHU #8 Return Duct Detector 3 48 037 37 AHU #9 Supply Duct Detector 3 49 038 38 AHU #9 Return Duct Detector 3 49 039 39 AHU #10 Supply Duct Detector 3 50 040 40 ' AHU #10 Return Duct Detector 3 50 041 41 1 AHU #11 Supply Duct Detector 3 51 042 42 AHU #11 Return Duct Detector 3 51 043 43 AHU #12 Supply Duct Detector 3 52 044 44 AHU #12 Return Duct Detector 3 52 Part Number AL400U.X Standby Battery Calculations Altronix AL4000LX JCPenney Seattle, WA 98188 Description Quantity Power Supply 4A @12 or 3A (dJ 24V[ 1 Standby Current Alarm Current Per Device AI Devices Per Device All Devices 0.060 0.060 0.060 0.060 Auxiliary devices Maxm.im3 Amps A77-7166 Pow er Supervisory Relay Total Aux current 2 0.019 0.038 0.000 Max 3 Amps 0.098 Standby Hours Standby Battery Draw Standby Amp Firs 24 0.098 2.352 Alarm Current Alarm Current 5 Mn 0.098 0.008 Battery Size Required with 5 Mn. AlarmTirne and 20% Reserve 2.832 !Battery Size Supplied 7 A.H. 0.019 0.038 0.000 Alarm 0.098 Sequence of Operation Standby Battery Calculations FireLite MS9600 JCPenney 0.000 0.000 ii 0 In be `� U1 q id el Seattle, WA 98188 Transmits alarm signal to UL listed manitorig center Transmits supervisory signal to UL Fisted mortaring center Transm#s trouble to UL listed monitorhg center. Standby Current Alarm Current Part Number Description Quantity Per Device Al Devices Per Device All Devices MS9600 Fire Alarm Control 1 0.120000 0.120000 0.170000 0.170000 DACT UD Dual Line Dialer 1 0.100000 0.100000 0.132000 0.132000 LCD -80F Annunciator LCD 1 0.025000 0.025000 0.064000 0.064000 SD355 Stroke Detector Photo 6 0.000300 0.001800 0.000300 0.001800 H355R Heat Detector Rate of Rise 0 0.000300 0.000000 0.000300 0.000000 M7F 300 Monitor Module Dual input 6 0.000750 0.004500 0.000750 0.004500 PTF -300 Monitor Module Single input 3 0.000400 0.001200 0.000510 0.001530 MM -301 Montior Module Smal 8 0.000375 0.003000 0.000375 0.003000 CRF -300 Control Module Relay 14 0.000270 0.003780 0.000510 0.007140 D350FL Duct Stroke Detector 25 0.000300 0.007500 0.000300 0.007500 RTS451 KEY Rermte test Sw itch 25 0.000000 0.000000 0.008000 0.200000 x Voltage Drop = 2 " Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 0.000000 0.000000 x Total Aux current Max 3 Arrps 0.267 Alarm 0.591 x Signal Circuits Standby Amp Hrs 5.400 0.000 0.000 Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1 AL1002UL-ADA-J 0.175 0.000 x ' Battery Size Supplied 18 A.H. 0.000 0.000 0.000 x x x 0.000 Total 1 Maxllum2.5 Mips 0.000 Circuit 2 AL1002UL-ADA-J 0.175 0.000 Totals Maximum 10 Amps 3.208 Circuit 1A Circuit 2A Circuit 3A 0.000 Max Wire Run Distance For AWG 14 668 792 Smoke detectors Actual Wire run Distance 450 375 0.000 Voltage Drop for 14 AWk3 w ire 2.694 1.895 Circuit 1B Circuit 2B Circuit 3B 0.000 Total2 Maxitrum2.5 Amps Actual Wire run Distance 400 400 0.000 Circuit 3 P2RK-110 1 0.212 0.212 x Standby Hours 60 and a rnininum voltage at the end of One of 18 Volts. 0.000 Calculations assume that al devices are at the end of the line. Standby Arrp Firs 5.400 0.000 x x x 0.000 Total3 Maximum 2.5 Amps 0.212 Circuit 4 Battery Size Required with 5 Mn. Alarm Time and 20% Reserve 6.817 0.000 i I Battery Ste Supplied 18 A.H. 0.000 0.000 x 0.000 Total4 Maximum2.5 Arrps x 0.000 Totals Maxirrum6 Amps 0.212 Circuit 1 Circuit 2 Circuit 3 Circuit 4 Max Wire Run Distance For AWG 14 3073 Actual Wire run Distance 100 Voltage Drop for 14 AWG w ire 0.130 Voltage Drop = 2 *Wre Run Distance * 3.07 Ohms Per 1000 ft 14 AWG' Total Current for Circuit / 1000 x Standby Hours 60 Standby Battery Draw 0.267 Standby Amp lis 16.007 Alarm Current 0.803 Alarm Current 5 Mn 0.067 Battery Size Required with 5 Mn. Alarm Tire and 20% Reserve 19.288 !Battery Size Supplied 25 A.H. Part Number AL400U.X Standby Battery Calculations Altronix AL4000LX JCPenney Seattle, WA 98188 Description Quantity Power Supply 4A @12 or 3A (dJ 24V[ 1 Standby Current Alarm Current Per Device AI Devices Per Device All Devices 0.060 0.060 0.060 0.060 Auxiliary devices Maxm.im3 Amps A77-7166 Pow er Supervisory Relay Total Aux current 2 0.019 0.038 0.000 Max 3 Amps 0.098 Standby Hours Standby Battery Draw Standby Amp Firs 24 0.098 2.352 Alarm Current Alarm Current 5 Mn 0.098 0.008 Battery Size Required with 5 Mn. AlarmTirne and 20% Reserve 2.832 !Battery Size Supplied 7 A.H. 0.019 0.038 0.000 Alarm 0.098 Sequence of Operation Auxilary devices Maximum 3 Amps 0.000 0.000 ii 0 In be `� U1 q id el II C l Transmits alarm signal to UL listed manitorig center Transmits supervisory signal to UL Fisted mortaring center Transm#s trouble to UL listed monitorhg center. 1 Yd h 0 c! I ii 1 _ 1 Turn on Lights through BNS Light Contra 1g ld ld N Activates exterior horn strobe Sprinkler system Auxilary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device Al Devices Circuit 1A PC2W30 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 1.031 Circuit 1B PC2V-30 7 0.107 0.749 Water flow x 0.000 1.031 x Circuit2A PC2WH-177 2 0.290 0.580 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 x x x x x 0.000 Valve tamper Total2 Maximum 2.5Amps 2.291 x FC2W-30 4 0.107 0.428 SCW-15 2 0.066 0.132 x 0.912 Circuit 3B PC2W-75 4 0.176 0.704 PC2W-30 5 0.107 0.535 0.000 0.000 1.239 Total 3 Maximum 2,5Amps 2151 Circuit 4A P2W-75 3 0.176 0.528 Air Pressure ugh 0.000 x 0.740 Circuit4B P2W-75 3 0.176 0.528 x 0.000 0.000 0.740 Total4 Maximum 25Arms 1.480 Totals Maximum 10 Amps 7.984 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 632 576 714 880 Actual Wire run Distance 550 475 450 550 Air Pressure Low x Max Wre Run Distance For AWG 14 832 562 526 880 Actual Wire run Distance 575 350 450 550 x Voltage Drop = 2 " Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts 1.363 x x x x x Calculations assume that all devices are at the end of the ine. Standby Amp Hrs 5.400 0.000 0.000 Circuit 3B Alarm Current 8.159 Alarm Current 5 Min 0.677 0.000 0.000 Battery Size Required with 5 Mn. AlarmTlme and 20% Reserve 7.293 Manual pull station x ' Battery Size Supplied 18 A.H. x 0.000 x x x x 0.000 0.000 0.000 0.000 Total4 Maxirrum2.5Arrps 0.000 Totals Maximum 10 Amps 3.208 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 668 792 Smoke detectors Actual Wire run Distance 450 375 Voltage Drop for 14 AWk3 w ire 2.694 1.895 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 749 1206 Actual Wire run Distance 400 400 Vokage Drop for 14 AVM ire 2.137 1.326 . Voltage Drop = 2 • Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AVVG • Total Current for C ircuk / 1000 Calculations are based on a rrinirum supply voltage of 20.4 Volts at panel x Standby Hours 60 and a rnininum voltage at the end of One of 18 Volts. x Calculations assume that al devices are at the end of the line. Standby Arrp Firs 5.400 x x x x Alarm Current 3.383 Alarm Current 5 Mn 0.281 Battery Size Required with 5 Mn. Alarm Time and 20% Reserve 6.817 i I Battery Ste Supplied 18 A.H. Duct smoke detectors x x x Abnormal circuit or device . x x System Outline Location JCPenney 0696-5 1200 Southcenter Mal Seattle, WA 98188 Codes A. 2002 NEPA 72 Chapters 1-10 as Appicable(Rermte Station) B. 2002 NBC Articles 250, 725, 760 C. Local, City, State R Control A. B. C. D. 1 MS9600 1 DACT UD 5 AL1002UL-ADA-J 1 AL4000LX N. Fire Alarm Initiating Devices A. 1 BG-12LX B. 6 SD355 C. 0 D. 25 E. 4 F. 9 G. 2 H355R D350PL Water Flow Tamper Switch Air Pressure V. Fire Alarm Indicating Devices A. 1 LCD -80F B. 46 PC2Wt-t-177 C. 5 PC2W-115 D. 27 PC2W-75 E 46 PC2Wr-30 F. 3 PC2W-15 G. 2 P2W-110 H 6 P2W-75 L 4 P2W-30 J. 4 SCWH-177 K. 8 SCW-115 L. 18 SCW-75 M. 44 SCW30 N. 9 SCW-15 O. 2 SW -30 P. 2 SW -15 Q. 1 F2RK 110 VL Zones AI devices are addressable with there own address 1-159 detector addresses 1-159 module addresses SLC Loop is style 4 Fire Alarm Control Dual Line Dialer ADA Power Booster 10AQ24VDC Power Supply 4A ig 12 or 3A di 24VDC Manual PW Station Addressable Stroke Detector Photo Heat Detector Rate of Rise Duct Stroke Detector Connection Only, Provided by Others Connection Only, Provided by Others Connection Only, Provided by Others Annunciator LCD Ceiing Horn strobe white 24VDC 177CD Ceilng Horn strobe w Me 24VDC 115CD Ceiling Horn strobe white 24VDC 75CD Ceilng Horn strobe w hite 24VDC 30CD Ceilng Horn strobe white 24VDC 15CD Wal Horn strobe white 24VDC 110CD Wal Horn strobe white 24VDC 75CD Wal Horn strobe white 24VDC 3000 Ceilng Strobe white 24VDC 177CD Ceilng Strobe white 24VDC 115CD Ceilng Strobe white 24VDC 75CD Ceiling Strobe w hite 24VDC 30CD Ceilng Strobe w hits 24VDC 15CD Wal Strobe w Me 24VDC 30CD Wal Strobe w hits 24VDC 15CD Wal Horn strobe RED 24VDC Weather Proof VI. Wring Al Circuits and Wiring Shall be "Pow er Limited" SLC Circuits Shall be 16/2 Shielded UL. FPLP Cable Initiating Zones Shal be 18/2 or 18/4 U.L. FPLP Cable Indicating Circuits Shal be 14/2 U.L. FFLP Cable System Ground Shal be 14 TI -NMN Green Conductor Under Ground and Outside Wre shall be 14 THWN in Approved Raceway VIII. Listings A. Al Equipment Shal Be U.L. Listed and Compatible IX. Power Supply A. Rirnary -110 VAC Dedicated 20 Amp Circuit B. Secondary - 25 Amp Hour Battery X. Alarm Supervision A. Human B. Remote Station ADT Fire & Security 14200 E Exposition Blvd. Aurora, CO 80012 (303) 338-8200 S994-183 WFX ilstaling Branch/Contractor A17T Tyco Fire & Security 11824 No Creek Perim ay Bothell, WA 98011 (206) 624-3103 Standby Battery Calculations Altronix AL1002ULADA #3 JCPenney Seattle, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device Al Devices Per Device All Devices AL1002U.-ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Auxilary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device Al Devices Circuit 1A PC2W30 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 1.031 Circuit 1B PC2V-30 7 0.107 0.749 SCVV-30 3 0.094 0.282 0.000 0.000 1.031 Totall Maximum 2.5Arrps 2.062 Circuit2A PC2WH-177 2 0.290 0.580 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 SCW1-i-177 1 0.281 0.281 1.131 Circuit 2B PC2VVhl.177 4 0.290 1.160 0.000 0.000 0.000 1.160 Total2 Maximum 2.5Amps 2.291 Circuit 3A PC2W-75 2 0.176 0.352 FC2W-30 4 0.107 0.428 SCW-15 2 0.066 0.132 0.000 0.912 Circuit 3B PC2W-75 4 0.176 0.704 PC2W-30 5 0.107 0.535 0.000 0.000 1.239 Total 3 Maximum 2,5Amps 2151 Circuit 4A P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 0.000 0.000 0.740 Circuit4B P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 0.000 0.000 0.740 Total4 Maximum 25Arms 1.480 Totals Maximum 10 Amps 7.984 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 632 576 714 880 Actual Wire run Distance 550 475 450 550 Voltage Drop for 14 AWGw ire 3.482 3.299 2.520 2.499 Circuit 1B Circuit 28 Circuit 3B Circuit 4B Max Wre Run Distance For AWG 14 832 562 526 880 Actual Wire run Distance 575 350 450 550 Voltage Drop for 14 AWGw ire 3.640 2.493 3.423 2.499 Voltage Drop = 2 " Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts 1.363 Circuit 3A Standby Hours 60 and a minimum voltage at the end of line of 18 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the ine. Standby Amp Hrs 5.400 0.000 0.000 Circuit 3B Alarm Current 8.159 Alarm Current 5 Min 0.677 0.000 0.000 Battery Size Required with 5 Mn. AlarmTlme and 20% Reserve 7.293 • Circuit 4A ' Battery Size Supplied 18 A.H. 0.000 Standby Battery Calculations ' Altro nix AL1002ULADA #1 JCPenney Seattle, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device Al Devices Per Device Al Devices AL1002UL-ADA-J ADA Power Booster 10A@24V 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Arrps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1A PC2W-30 2 0.107 0.214 SCW-30 4 0.094 0.376 PC2W-75 1 0.176 0.176 PC2WH-177 2 0.290 0.580 1.346 Circuit 1B PC2W-75 3 0.176 0.528 SCW-75 2 0.158 0.316 PC2W-30 2 0.107 0.214 0.000 1.058 Total 1 Maximum 2.5 Amps 2.404 Circuit2A PC2WH 177 3 0.290 0.870 PC2Wr-115 1 0.218 0.218 SCW-75 1 0.158 0.158 0.000 1.248 Circuit 2B PC2WF-177 3 0.290 0.870 PC2W-115 1 0.218 0.218 0.000 0.000 1.088 Total2 Maximum2.5Amps 2.334 Circuit 3A PC2WH-177 3 0.290 0.870 SCVV=115 1 0.210 0.210 SCW-75 1 0.158 0.158 0.000 1.238 Circuit 3B SCW-30 3 0.094 0.282 PC2W-30 1 0.107 0.107 PC2W-75 2 0.176 0.352 PC2WH-177 1 0.290 0.290 1.031 Total 3 Maximum2.5 Amps 2.269 Circuit4A PC2WH-177 2 0.290 0.580 SCW-115 1 0.210 0.210 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 1.060 Circuit4B SCW-30 1 0.094 0.094 PC2W-30 1 0.107 0.107 PC2W-75 2 0.176 0.352 SCVV-75 3 0.158 0.474 1.027 Total4 Maximum 2.5 A rips 2.087 Totals Maximum 10 Arrps 9.094 Circuit 1A Circuit2A Circuit3A Circuit4A Max Wire Run Distance For AWG 14 484 523 526 615 Actual Wire run Distance 375 400 350 375 Voltage Drop for 14 AWG w ire 3.099 3.060 2.660 2.441 I Circuit1B Circuit28 Circuit3B Circuit48 Max Wre Run Distance For AWG 14 616 599 632 634 Actual Wre run Distance 525 300 550 550 Voltage crop for 14 AWG w Ire 3.410 2.004 3.482 3.468 Voltage Drop = 2 *Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AVG • Total Current for Circuit / 1000 Calculations are based on a ninhum supply voltage of 20.4 Volts 1.363 Circuit 3A Standby Hours 60 and a ninirrum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that el devices are at the end of the Ins. Standby Amp Its 5.400 0.000 0.000 Circuit 3B Alarm Current 9.269 Alarm Current 5 Mn 0.769 0.000 0.000 Battery Size Required w itis 5 Min. Alarm Time and 20% Reserve 7.403 0.000 Circuit 4A ' 'Battery Size Supplied 18 A.H. 0.000 Standby Battery Calculations Altro nix AL1002ULADA #4 JCPenney Seattle, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device Al Devices Per Device Al Devices AL1002UL-ADA-J ADA Power Booster 1OA@24VDC 1 0.090 0.090 0.175 0.175 Auxliary devices Maximum 3 Arrps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1A SCWH-177 1 0.281 0.281 SCW-75 2 0.158 0.316 SCW-30 3 0.094 0.282 PC2W-115 1 0.218 0.218 1.097 Circuit 1B PC2W1-4177 4 0.290 1.160 0.000 0.000 0.000 1.180 Total1 Maxinum2.5Amps 2.257 Circuit2A FC2WH-177 1 0.290 0.290 FC2W-30 2 0.107 0.214 SCWI.115 1 0.210 0.210 PC2W-115 1 0.218 0.218 0.932 Circuit2B PC2WH-177 3 0.290 0.870 SCW-115 1 0.210 0.210 PC2W-30 1 0.107 0.107 0.000 i 1.187 Total2 Maximum 2.5 Amps 2.119 Circuit 3A PC2WH-177 1 0.290 0.290 SCW-115 1 0.210 0.210 PC2W-75 2 0.176 0.352 0.852 Circuit 38 PC2WH-177 3 0.290 0.870 PC2W-75 1 0.176 0.176 0.000 1.046 Total3 Maximum 2.5Arrps 1.898 Circuit4A PC2WH•177 1 0.290 0.290 SCW-115 1 0.210 0.210 PC2W-75 1 0.178 0.178 SCW-30 3 0.094 0.282 0.958 Circuit4B SCW-115 1 0.210 0.210 SCW -15 2 0.068 0.132 SCW -30 1 0.094 0.094 SCW -75 1 0.158 0.158 PC2W-75 1 0.178 0.178 PC2Wl-1.177 1 0.290 0.290 1.060 Total4 Maximum 2.5 Amps 2.018 Totals Maximum 10 Arrps 8.292 Circuit1A Circuit2A Circuit3A Circuit4A Max Wre Run Distance For AWG 14 594 899 765 680 Actual Wire run Distance 550 450 425 550 Voltage Drop for 14 AWR3 w ire 3.705 2.575 2.223 3.235 Circuit 1B Circuit2B Circuit3B Circuit4B Max Wire Run Distance For AWG 14 562 549 623 615 Acival Wire run Distance 425 425 425 500 Voltage Drop for 14 AWG w ire 3.027 3.097 2.730 3.254 Voltage Drop = 2 " Wire Run Distance *3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts 1.363 Circuit 3A Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that al devices are at the end of the ine. Standby Amp Its 5.400 0.000 0.000 Circuit 3B Alarm Current 8.467 Alarm Current 5 Mn 0.703 0.000 0.000 Battery Size Required w Ith 5 Min. Alarm Time and 20% Reserve 7.323 0.000 Circuit 4A ' 'Battery Size Supplied 18 A.H. 0.000 Standby Battery Calculations Altronix AL1002ULADA #2 JCPenney Seattle, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All Devices AL1002LA-ADA-J ADA Power Booster 10A .24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device Al Devices Circuit 1A SCW-30 5 0.094 0.470 SCW-75 1 0.158 0.158 PC2W30 1 0.107 0.107 PC2W-75 1 0.176 0.176 SCW/-15 1 0.066 0.066 SCW-115 1 0.210 0.210 1.187 Circuit 1B PC2WH-177 1 0.290 0.290 SCW-30 2 0.094 0.188 SCWA15 1 0.066 0.066 SCW-75 2 0.158 0.316 0.860 Total 1 Maximum 2.5 Amps 2.047 Circuit 2A SCW-30 4 0.094 0.376 PC2W-30 2 0.107 0.214 SCW-75 1 0.158 0.158 0.748 Circuit 2B PC2W-30 1 0.107 0.107 SW -30 2 0.094 0.188 F2VV-30 4 0.107 0.428 SW -15 2 0.066 0.132 0.855 Total 2 Maximum 2.5 Amps 1.603 Circuit 3A PC2VvH-177 3 0.290 0.870 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 0.000 1.140 Circuit 38 SCWH-177 2 0.281 0.562 PC2W-115 1 0.218 0.218 PC;2VVH.177 2 0.290 0.580 0.000 1.360 Total 3 Maximum 2.5Arrps 2.500 Circuit 4A PC2VV1-1-177 4 0.290 1.160 0.000 0.000 1.160 Circuit 48 FG2WH-177 2 0.290 0.580 PC2W 30 3 0.107 0.321 SCW-75 1 0.158 0.158 0.000 1.059 Total4 Maximum 2.5 Amps 2.219 Totals Maximum 10 Amps 8.369 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 549 871 571 562 Actual Wire run Distance 425 525 425 350 Voltage Drop for 14AWGwire 3.097 2.411 2975 2.493 Circuit 18 Circuit 28 Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 758 762 479 615 Actual wire run Distance 400 500 350 525 Voltage Drop for 14 AWGwire 2.112 2.625 2.923 3.414 Voltage Drop = 2 • Wire Run Distance " 3.07 Ohms Per 1000 ft 14 AWG * Total Current for Circuit/ 1000 Calculations are based on a rrinirumsupply voltage of 20.4 Volts 1.363 Circuit 3A Standby Hours 60 and a ninirnumvoltage at the end of fine of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp His 5.400 0.000 0.000 Circuit 3B Alarm Current 8.544 Alarm Current 5 Mn 0.709 0.000 0.000 Battery Ste Required with 5 Mn. Alarm Time and 20% Reserve 7.331 0.000 Circuit 4A ' Battery Size Supplied 18 A.H. 0.000 Standby Battery Calculations Altronix AL1002ULADA #5 JC Penney Seattle, WA 98188 Standby Current Part Number Description Quantity Per Device All Devices AL1002LJL-ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 Alarm Current Per Device All Devices 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device Al Devices Circuit 1A PC2W-30 5 0.107 0.535 SCW-30 3 0.094 0.282 SCW-75 1 0.158 0.158 0.000 0.975 Circuit 1B PC2W-30 1 0.107 0.107 PC2W--15 1 0.079 0.079 PC2W-75 1 0.176 0.176 SCW-30 4 0.094 0.376 SCW-15 2 0.066 0.132 0.870 Total1 Maximum 2.5Arrps 1.845 Circuit2A PC2W-30 1 0.107 0.107 PC2W-75 1 0.178 0.176 PC2W-15 2 0.079 0.158 . SCW-15 1 0.066 0.066 SCW-75 2 0.158 0.316 0.823 Circuit 2B PC2W-75 2 0.176 0.352 SCW-30 2 0.094 0.188 0.000 0.000 0.540 Total2 Maximum 2.5Arrps 1.363 Circuit 3A 0.000 0.000 0.000 0.000 0.000 Circuit 3B 0.000 0.000 0.000 0.000 Total 3 Maxinum2.5 Amps 0.000 Circuit 4A 0.000 0.000 0.000 0.000 0.000 Grcult 4B 0.000 0.000 0.000 0.000 Total4 Maxirrum2.5Arrps 0.000 Totals Maximum 10 Amps 3.208 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 668 792 Actual Wire run Distance 450 375 Voltage Drop for 14 AWk3 w ire 2.694 1.895 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 749 1206 Actual Wire run Distance 400 400 Vokage Drop for 14 AVM ire 2.137 1.326 . Voltage Drop = 2 • Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AVVG • Total Current for C ircuk / 1000 Calculations are based on a rrinirum supply voltage of 20.4 Volts Standby Hours 60 and a rnininum voltage at the end of One of 18 Volts. Standby Battery Draw 0.090 Calculations assume that al devices are at the end of the line. Standby Arrp Firs 5.400 Alarm Current 3.383 Alarm Current 5 Mn 0.281 Battery Size Required with 5 Mn. Alarm Time and 20% Reserve 6.817 i I Battery Ste Supplied 18 A.H. SCALE = NTS TITLE: FIRE SYSTEM DEVICE LOCATIONS FILE NO. JCP 0696 6501 LEGACY DRIVE, MS 0046 PLANO, TEXAS 75024 PH: (972)-431-1275 FAX: (972)-431-3203 U Scale: Southcenter Mall co co CO Seattle, WA NTS Calculations BY DLJ DLJ Drawn By: Checked: JCP Prints: DLJ REVISIONS: REV. DATE NOTES: 1 1/16/2008 Updated per JCP Rev 1 dated 1/11/2008 2 I 2/14/2008 Updated per JCP Rev 2 dated 1/31/2008 DLJ 3 DLJ 4 3/6/2008 4/25/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. Added equipment to release door holders. Added relays to release roll -up gates at mall. Elevators not capable of recall, equipment removed. DLJ i 5 Revised per JCP Rev 4 dated 6/13/2008. Revised 6/19/2008 one Fitting Room, updated mall entrance and Door Holders MO i 6 6/19/2008 Replaced HVAC units in salon and office area Replaced duct detectors on those units SHEET \0: 10 OF 10 MATCHLINE MATCHLINE WOMENS FR I 30 FIRE EXIT _.._.._.._.._.._...I-.. CD -r— STAIRS L I z z 177CD �C n PB -3 FASHION JEWELRY I - -- T ES WOMENS SHOES n SHOES NETSELL TO PB 177CD IC KI6S SH -GES TD PS I FIRE ALARM RELAY CONNECTED CRF TO DOOR HOLDERS TO RELEASE— I I DOORS DURING A FIRE ALARM, I 1 =1 PB -3 CIR-1A EOL P I I F ,-Vi ELEVATOR NOT CAPABLE OF RECALL. WIRE WILL BE RUN TO ELEVATORS FOR FUTURE ELEVATOR UPGRADE. FIRE ALARM RELAY CONNECTED TO DOOR HOLDERS TO RELEASE DOORS DURING A FIRE ALARM. TO PB PI n 1 -.._.._.._.._.._.._.._.._.._.._.._.._.._.._. -1-to-NDEgA n OUTERW PB -2 CIR-4B EOL 3rYi FROM 1ST FLOOR 30CD C I J FREIGHT ELEVATOR IpI30CD UP 3 UP L_�__-.J J 30CD C O C 3U.;ll 30CD A C C SHOES STOCK 0 13CD ALL FIRE ALARM WIRE BELOW MEZZANINE TO BE IN CONDUIT PB -3 CIR-1B EOL UPPER LEVEL SHOE STOCK O 30CD C Ai 30C I C I x w 30CD C O z 1 I II-.._.._.._ L _.._..- 75CD C 30CD C L.._ —J FREIGHT ELEVATOR TO PB I I I I I Z30CD C 30CD I xi 3U.; ti DN 1 nJbcD 1----F-141 4 30CD C r t3 C I I I t1CD 30Lll IC T I I I DN 30CD 30CD [h 30CD C FREIGHT ELEVATOR LL. MATCHLINE MATCHLINE it NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. Building Key: FILE COPY Zvi sioh TuKWILA FIRE DEPARTMEN Please call: 575-440Z .--- and give this job 4 ' .xact address for shuts or restoration aporovaI 8' 4 0 8' SCALE 1/8"=1'-0" FIRE SYSTEM DEVICE LOCATIONS JCP 0696 Southcenter WA 98188 UD C O CV Alarm Plans (1.) 4.4 1/8"=1'-0" 1/11/2008 BW DLJ 12/5/2007 I, DLJ 1 1/16/2008 DLJ 2 2/14/2008 DLJ 3 I 3/6/2008 DLJ 4 4/25/2008 Updated per JCP Rev 1 dated 1/11/2008 Updated per JCP Rev 2 dated 1/31/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. Added equipment to release door holders. Added relays to release roll•up gates at mall. Elevators not capable of recall, equipment removed. SHEET NO: 5 OF 10 Owner information JCPenney 6501 Legacy drive Plano, TX (972) 431-1000 Real Estate Dept. 0 c Without Comments As Noted In Red Per The ,attached Letter ► nese plans have been reviewed by The Tukwila Fire Prevention Bureau for car ,fc..-i"i ante with current city sta:3r' 'sfds, fic,:r:,r .. ,qua it �,,, ie t to errors and omf..t=icr1$ 1.i' li^'i'i rh.:? .:utbori. e 1/!rJlrah ns of adopted stars:::;zos and ere };:Tic.:'a. The rer3consibl&y for the adequacy of ds ., li , tot,_,ily with the designer. Additions, deletions o! }c,:i s:o!3r=. to these drawings after this date will void thi6.accep lance ?nd will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Firs Prevention BureOU. Date: Y-/( -o 2 -1/ Installing contractor ADT Security Service 11824 No Creek Parkway Bothell, WA 98011 (206) 624-3103 Fire alarm designer ADT Security Service Brad Welch .CEP1104032 120 West Park Dr. Birmingham, AL 35211 (205) 943-6520 Monitoring Center ADT Security Service 14200 Exposition Ave Aurora, CO 80012 Phone (303) 338-8200 UL Listing Number S994- 183 U U FX Fire Departmenta:ntact Tukwilla Firerevention 444 Andover Park East Tukwilla, WA 98188 (206) 575-4404 Al Metzler Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 or email. fireinsprequest(aci.tulcwila.wa.us to schedule your inspections a minimum of 43 hours in'advance of the date yoti want an inspection, IUKWILA FIRE DEPARTMEN Please call: 575-4407, and give this job No0�-��ia 3 ,, and exact address for shut. down or restaration approve; NOTICE ICE A completed, signed, Tukwila Fire Department Pre-test certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems, Faure of test will result in a Reins ion Fee and termination of the testing. SCALE = NTS FIRE SYSTEM DEVICE LOCATIONS JCP 0696 Code Section 1„6o7 NFPA 72 Fire alarm code 2 Edition NFPA 70 National electrical code 2002 Edition International Fire Code 2006 edition as amended International Building Code 2006 edition as amended International Mechanical Code 2006 edition as Amended ANSI 117.1 Accessibility code. Scope of work Replacement addressable fire alarm system. The fire alarm control panel and all power supplies are to be mounted in the sprinkler room. They are to be powered 'by dedicated 120VAC circuits that are to be locked and labeled FIRE ALARM DO NOT TURN OFF. The fire alarm is to be monitored as a remote station at ADT Security service, Aurora, CO. By a dual line dialer connected to 2 existing shared loop start phone lines. The following conditions are to be monitored. All water flow switches as alarm. All sprinkler valves asa supervisory. Smoke detector at the fire dlarm panel per NFPA 72. Manual pull stations the fire 'panel, as alarm. Duct detectors are to be installed in the Supply and Return duct and monitored as a 'supervisory signal. The duct detectors are to shut down their own unit. '. Occupant notification is to be public mode. All horns and strobes shall be synchronized. General notes: 1. All fire alarm devices are to be installed according the 'the requirements of NFPA 72 and the manufactures instructions. 2. All fire alarm devices are to be mounted on back boxes. 3. All fire alarm devices are to be UL Listed and compatible. 4. All wire is to be in conduit from the device back box to above the false ceiling or to the bar joists. Wire may be run exposed horizontally but must be attached to the building structure or supported by approved hangers. 5. All wire is to be Power Limited, Type FPLP unless otherwise noted. All wiring is to be installed in accordance with the adapted NFPA 70 (NEC Section 760), NFPA 72 and all local codes. 6. Control panels and power supplies are to be mounted in the sprinkler room unless the AHJ requires otherwise. They are to be mounted no more that 72 inches above the floor to the top of the cabinet. 7. Annunciator/Keypads are to be mounted at 60 inches above the floor to the top of the unit unless the AHJ requires otherwise. 8. Manual pull stations are to be mounted at 48 inches above the floor to the center of the box unless the AHJ requires otherwise. 9. Wall mounted horns and strobes shall be mounted at 80 inches to the bottom of the box above the finished floor.The candela rating is noted near the device on the drawings. 10. Ceiling mounted horns and strobes will be noted with a "C".The candela rating is noted near the device on the drawings. 11. All control cabinets and power supplies cabinets are to have tamper switches and be monitored by the fire alarm. 12. The HVAC Contractor is to mount the duct detectors, and wire the HVAC shutdown to the associated ADT supplied control module. ADT is to supply,wire and power the duct detectors. Duct detectors are to be installed in the Return duct.. and/or supply : duct as required by local codes. 13. The JCPenney electrical contractor is to supply all required 120VAC to the fire alarm control panel and all power supplies on dedicated Circuit(s). The circuit(s) are to be locked and label "FIRE ALARM DO NOT TURN OFF". 14. The JCPenney electrical contractor is to supply all conduit stub ups, back boxes, power supply inter connection conduit required and any under ground conduit and wiring to outside devices. The under ground wire is to be THHW or equal. 15. The GC is to supply a i" Plywood back board in the sprinkler room large enough to mount all controls, battery boxes and power supplies. 16. The JCPenney sprinkler contractor is to supply, install and adjust all sprinkler system supervisory switches. 17. Upon completion of the installation 2 sets of plans shall be marked up for as built. one set is to be left on site in a locked cabinet at the fire alarm control panel. The other set is to be returned to ADT, 6501 Legacy Dr. ,MS0046, Plano, TX 75014 Attn..: Cad Dept... Fire Alarm Legend Symbol Qty Description Manufacture/Part Number Mounting Requirements 1 Fire Alarm Control Panel FireLite MS9600 W/DACT-UD Surface mounted enclosure provided Top 72' AFF conduit to ceiling FCP 1 Fire Alarm Annunciator Alpha Keypad FireLite LCD -80F Single or double Gang, 4' square box 60' AFF conduit -to ceiling FSA 6 Addressable Dual Monitor Module FireLite MDF300 4' square deep box MDF 13 Addressable Monitor Module FireLite MMF300, MMF301 4' square deep box MMF ®P 17 Smoke Detector Photo Electric FireLite SD355 Single Gang, 3,5' Octagon or 4' Sq. Box in the ceiling OR 9 Heat Detector R of R 135 degor indicated Fire Lite H355R 3 1/4' Octagon box mounted In the ceiling P 0 Manual Pull Station FireLite BG-12LX Deep Single Gang Box 48' AFF to Center, Conduit to ceiling 25 Addressable Control Module FireLite CRF -300 4' square deep box CRF ®p 25 Duct Smoke Detector Photo Electric FireLite D350PL 1/2' Flex to 4' Square Box RI 25 Remote indicator Test/Reset FireLite RTS451KEY Single Gang Box Conduit to ceiling 8 4 Water Flow Switch Supplied by others 1/2' FLex to Deep 4' square box Conduit to ceiling &Sprinkler ,-T-, 9 Valve Tamper Switch Supplied by others 1/2' FLex to Deep 4' square box Conduit to ceiling ,.TQ 4 2 Air Pressure Switch Supplied by others 1/2' FLex to Deep 4' square box Conduit to ceiling 5 Signal Power Booster Altronix AL1002UL-ADA Surface mounted enclosure provided Top 72' AFF conduit to ceiling PB 4 Strobe Candella Indicated System Sensor SW or SWH Multi Candella Single or double Gang, 4' square box 80' AFF to bottom of box ):(C 83 Ceiling Strobe Candella Indicated System Sensor SCW or SCWH Multi Candella Single or double Gang, 4' square box Mounted to -the ceiling E 12 Horn Strobe candetla Indicated System Sensor P2W or P2WH Multi Candella Single or double Gang, 4' square box 80' AFF to bottom of box E_IC 126Candella Ceiling Horn Strobe Indicated System Sensor PC2W or PC2WH Multi Candella Single or double Gang, 4' square- box Mounted to the Ceiling Evip 1 Outdoor Horn Strobe Candella Indicated System Sensor P2RK Multi Candella Single or double Gang, 4' square box 84' -to 96" AFG to top of box 1 AAuxilary Power Supply Altronix AL4000LX Surface mounted enclosure provided Top 72' AFF conduit to ceiling PS C 2 Power Supervisory Relay A77 -716B 4' Square Box Conduit to ceiling IIso! Isolator Module Flrelite I300 4' square deep box SLC Circuit ADT-454747ARE 16 Ga 2 Cond Shielded FPLP Annuclator Circuit ADT-454746ARE 18 Ga 6 Cond Shielded FPLP Power Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Notification Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Duct Detector Test Station ADT-474711ARE 18 Ga 4 Cond FPLP Device Wiring ADT-474711ARE 18 Ga 4 Cond FPLP Building Information Occupancy Type "M" Mercantile Number of stories 3 Sq Footage: 236,000 1st fir: 78,000 2nd fir: 80,000 3rd fir: 78,000 Sheet index 1 = Cover sheet 2 = First Floor Area 1 3 = First Floor Area 2 4 = Second Floor Area 1 9 = Riser diagram 10 = Battery calculations NTS 1/11/2008 BW DLJ Fire Alarm Device Locations 1 st Floor Fire Alarm Device Locations 2nd FLoor Fire Alarm Device Locations 3rd Floor 1/16/2008 2/14/2008 3 3/6/2008 Updated per JCP Rev 1 dated 1/11/2008 Updated per JCP Rev 2 dated 1/31/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. ATHLETIC SHOES MEN'S SHOES FNS OLO1 HING ihllllliQlllmor ::1uim11111M11mnii1111•i111111111i:::::: ACCESSORIES CHILDRENS INPANTS RI ® RI RI ©p TO ©D ©D RI ® RI RI ©D ©D ©D ©D YOUNG MENS CRF CRF PORTRAIT STUDIO NEW MALL ENTRANCE PENTHOUSE ON ROOF IS NOT TO SCALE DIMENSIONS WERE TAKEN FROM AN OVERHEAD VIEW OF THE SITE PLAN SHEET \ 1 OF 10 c; ,) 2 2008 Tukwila Fire .2774' STAIRS SECURITY OFFICE 16'-1" C.H. 30CD C 7'-1" HIGH HEADER SPRINKLE ROOM NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT ANTE ROOM OPTICAL OFFICE STAIRS OFFICE MACHINE ROOM 8'-O" CEILING 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. MODULE TO TURN LIGHTS ON DURING A FIRE ALARM THROUGH EMS FIRE SYSTEM DEVICE LOCATIONS OFFICE JCP 0696 ELEVATOR MACHINE ROOM PB -2 CIR-1A EDL WINDOW 4'-7" HIGH PARTITION 3'-6" HIGH PARTITION INTER IEW 30CD C 42"i HIGH PARTITION 8'-11" CEILING JANITOR CLOSET CONCRETE FLOOR INTIMATE RECEPTION AREA CONFERENCE ROOM TRAINING ROOM PB -2 CIR-1B EEL BATH SHOP SALES SUPPORT MANAGER SALES SUPPORT MANAGER PB -2 CIR-2A EEL BUSINESS PLANNING MANAGER BUSINESS PLANNING MANAGER STORE MANAGER 1/8"=1'-0" 1/11/2008 BW DLJ 3/7/2003 MONEY ROOM VAULT PB -1 CIR-4B EEL PB -1 CIR-4A EEL DLJ 1 1/16/2008 DLJ 2 2/14/2008 DLJ 3 3/6/2008 Updated per JCP Rev 1 dated 1/11/2008. No Prints This Floor Updated per JCP Rev 2 dated 1/31/2008 No Prints This Floor Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. PB -1 CIR-3A EEL MATERNITY PB -1 CIR-3B _..� L.._®_.._.._ OFFICE 30CD AISTING FITTING ROOMS UP TO 2ND FLOOR LOCKER ROOM TELEPHONE ROOM SECONDARY PHONE TRUNK SHEET N O : 2 OF 10 Air Pressure Outside Dry System PIVcilSystem fll III ,g o„g„ NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT SPRINKLER ROOM STAIRS SPRINKLER VALVE ROOM STAIRS / PB -1 C IR -1 A EEL 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. SCALE 1/8"=1'-0" FIRE SYSTEM DEVICE LOCATIONS JCP 0696 Building Key: 115CD BEDDING LP TO FIR; T r �2 HOUSEWARES HOME ACCESSORIES L _ PB -1 CI R -2B EDL FURNITURE / , / / / / / I ( / / / / 75CD '7177CD PB -1 CI R -2A ELL CU i OM DECOR PB -1 CIR-1B EDL STORAGE 0 0 Alarm 1/8"=1'-0" 1/11/2008 BW DLJ 3/7/2003 j Updated per JCP Rev 1 DLJ 1 1/16/2008 i datedl/11/2008. I No Prints This Floor DLJ 2 2/14/2008 Updated a ed 1d/per %200 P Rev 2 I No Prints This Floor Updated per Walkthrough. Removed Pull, added DLJ 3 3/6/2008 RlserDevices. Added Duct Detectors per Walkthrough. 7'0" C.H. SHEET \O: 3 OF 10 PB -3 CIR-3A EOL MATCHLINE MATCHLINE LL fn STAIRS STAIRS STO 30CD p 30CD 1 11 • 15CD 730CD C I I WOMEN FR Q 75CD NEW FITTING ROOMS ISTING 9'-0" CH Z._ 30CD TC I cD 0 0 J W U OFFICE rr STAIRS F 75CD l C SiTOpK II L.. FSA TO PB CEILING 10'-O" PRO -RATE TO FCP FACP CIR-3 EDL WPEZ 110CD W!W zIz J� _I =• I= F- 1 I - < IQ EXISTING PIPE CHISE TO FCP TO PB I I I I / 177CD TC 30 FIRE EXIT _,._.._.._.._.._«t.. _.L I I I I I I 177CD SEPHORA I I 7177CD I I SZ 177CD I I FINE JEWELRY I COSMETICS I /) ✓_�.__� 177CD C PB -3 CIR-2B EOL I 6.1 I C I X I LT LP 177CD FASHION JEWELRY I POS TO PB I TO PB -177CD j r 1 P�TITES TO PB \ 177CD C I HOSIt�RY I WOMEN ACCESS UP I 31D '.DOR BASDENT WOMENS ACCE: NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. Building Key: 8' 4 0 8' SCALE 1/8"=1'-0" FIRE SYSTEM DEVICE LOCATIONS JCP 0696 v .4q cNZS JCPenney {0696 1200 Southeenter Seattle, WA 98188 2nd Floor I Alarm Plans 1/8"=1'-0" 1/11/2008 BW DLJ 12/5/2007 DLJ DLJ 2 DLJ 3 1/16/2008 2/14/2008 Updated per JCP Rev 1 dated 1/11/2008 Updated per JCP Rev 2 dated 1/31/2008 Updated per Walkthrough. Removed Pull, added 3/6/2008 Riser Devices. Added Duct Detectors per Walkthrough. SHEET \O: 4 OF 10 MATCHLINE MATCHLINE CC LL z Lu 2 0 (-§ 1 STAIRS PB -3 CIR-1A EOL L z —..J PB -3 §i1R5 FASHION JEWELRY I ES WOMENS SHOES z SHOES NETSELL TO PB 177CD L4 -1C KICKS- SH -GEES _.._.._.._.._. _. _. _. _. z z z a z -HAND AG -S- -4 z OUTERW PB -2 CI R -4B EOL L z z FROM 1ST FLOOR t,30CD L FREIGHT z I p 30CD TO PB Y z t I 30CD p 3U. -D T 5 //7 UP 3bCD I Iii C 30CD — C l: P 3 1 1 1 1 1 1 ( 1 SOLD tC I I b�D SHOES STOCK ALL FIRE ALARM WIRE BELOW MEZZANINE TO BE IN CONDUIT PB -3 CIR-1B EOL UPPER LEVEL SHOE STOCK ELEVATOR L. _75CD p30CD EXISTING ELECTRICAL PANELS L.._ UP v 30CD 30CD —J UJ 0 FREIGHT ELEVATOR TO PB 30CD Y I I I p 3U.; DN 30CD ; 30CD C �C C OCD 30CD V//11///1 1 1 1 DN V 30CD C 30CD //i 30CL FREIGHT ELEVATOR MATCHLINE NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. Building Key: 8' 4 0 8' SCALE 1/8"=1-0" FIRE SYSTEM DEVICE LOCATIONS JCP 0696 1200 Southeenter °?5szb u.. 01) WA 98188 2nd Floor 1/8"=1'-0" 1/11/2008 BW DLJ 12/5/2007 DLJ 1 1/16/2008 DLJ 2 2/14/2008 DLJ 3 3/6/2008 Updated per JCP Rev 1 I dated 1/11/2008 Updated per JCP Rev 2 dated 1/31/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. SHEET NO: 5 OF 10 WOMENS FR 3 PIPE CHOSE STAIRS COM NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT STORAGE STAIRS ADD 3 NEW WALL HORN/STROBES TRUCK RAMP DOWN 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. SCALE 1/8"=1'-0" FIRE SYSTEM DEVICE LOCATIONS P�TITES RECEIVING v10VE P2W-1 10 TO NEW ROOM AND CHANGE TO P2W-30 V 30CD PB -2 CIR-2B EOL -<(( 15CD Building Key: RUN /\NUTI-IER CIRCUIT FROM 2B5, CE 20. IOSIERY WOMENS SIZES ✓IEN4 ACCESS :NS ACCESS kNE SAS.._.._.._.._.._.._.._.._.._ V 177CD DRESSES WOMENS APPAREL S177CD PB -2 CIR-3B EDL 1/8"=1'-0" 1/11/2008 BW DLJ PB -5 CIR-2B EDL DLJ 1 1/16/2008 DLJ 2 2/14/2008 DLJ 3 3/6/2008 jk Updated per JCP Rev 1 dated 1/11/2008 Updated per JCP Rev 2 dated 1/31/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. JUNIORS PB -2 CIR-4A EOL PB -2 CIR-3A EOL ELECTRIC PANELS STAIRS STAIRS HOSIERY STOCKROOM SHEET NO: 6 OF 10 Southeenter 0 0 Liar Ci) 0 rr�l F+1 CO Pt Cep VD I Alarm Plans 1/8"=1'-0" 1/11/2008 BW DLJ 12/5/2007 FIRE SYSTEM DEVICE LOCATIONS JCP 0696 8' 4 0 8' SCALE 1/8"=1'-0" DLJ 1 1/16/2008 DLJ 3 ! 3/6/2008 DLJ 2 2/14/2008 Updated per JCP Rev 1 dated 1/11/2008 Updated per JCP Rev 2 dated 1/31/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. SHEET NO: 7 OF 10 REARRANGE STROBES IN LOUNGE AND RESTROOMS. PB -5 CIR-1B EOL A/C ROOM RI RI r--CRF--�- L --I L ST 15C STAIRS AI- C L 1 =1 I 15CD P i � 30C IC i ) an L �� P PASSENGER r ELEVATOR 1 -J� L. O O ci 0 0 0 O r C C K C - 75CD I -1I C 1L PB -5 CIR-2A EOL L LOUNGE 15CD Fc WOMEN 75 MEN 30CD C C OJ .7 75CD 0 0 0 C C K 75_,D I 0 K C K C OFFICE p3 CHILD FITTIN 30CD OMS C 30CD PB -5 CIR-1A EOL I TO PB TO PB D I I 15C i 115CD INFANTS —C PB -4 CIR-4B EOL I p 75CD 8'-10" CEILING PORTRAIT STUDIO 7177CD TO PB N / 177CD C L.._ 30CD HILDRENS FITTING ROOMS - CLOSET L_ 75CD C I TO PB I I I CHIL[ RENS I I I I I I — GIRLS BOYS 30CD C STAIRS I j 30CD r' 30CD v 30CD IC 1" TILE FLOOR p 30CD —C 7177CD 3�.._.._..—{ TO PB 30CD r SHOE STOCKRO MTO PB 30CD C L. ATHLETIC SHOES '730CD iC LOCATE HORN STROBES IN STOCK AREAS FOR BEST COVERAGE AROUND SHELVING i 30CD � C I 7 30CD li _i MEN'S SHOES 177C.9 C I I / / / / / / / / I TO PB 0 ///r/,,/////////////// //l I I / / A -f HLETIC APPAREL i115C D EZ177CD L.._.._.._.._.._.._.. PLACE 30cd STROBES IN STUDIOS AND/OR CHANGING ROOMS 30CD 30CD 30CD PB -4 CIR-4A EOL 115CD C I L 1 I I I PB -4 CIR-3B EOL �75�D I A NG ROOMS J J I I I UP TO PENTHOUSE \ / FREIGHT I ELEVATOR I r---- p 1 --� MAIN MAIN V75CD C PB -4 CIR-3A EOL I I I T 177CD C N WIW NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. Building Key: ALTERATIONS V 75CD -OI CVCT TIL BOILER CONDEMNED 2.30CD li TO FACP �0 PS I� 30CD C I; i I —T1 / STAIRS P 75CD C — TO PB I r I I I I L n J p 75CD C it FITTINQMSC D IC _..H J J I V 177CD MENS CLOTHING I L. I 17 TO PB PB -4 CI R -2B EOL NS I I I F-- / __115CD .._., J , l / , / ,J / / / / L_/ Yfi FITTING 30CD OMSC / / / / I ; / / • / / / / / / / / / / / / / / • / / / I/ ,/ V 177CD \ I I I 30CD /1/_./ II lI// I I I I I \ i b 177CD IC wiw Ziz YOUNG MENS 177CD I),( C PB -4 CI R -2A EOL NEW MALL ENTRANCE I I I i 177CD C PB -4 CIR-1B EOL PB -3 ECIR-3B EDL I I TO PB 177CD C L.._.._.._..� I 75CD 1 1 iC ACCESSORIES PB -4 CIR-1A EOL I I 75CD C I I 8'-1"I CEILING 30CD C STOCK 5, 115CD C 8'-12" CEILING J 30CD i 30CD �C r RELOCATED ELECTRICAL PANELS TO PB �y.(( 75CD 75CD 75CD 5C D L.._ A 110CD ii TO PB ALL RELAYS FOR HVAC SHUTDOWN LOCATED IN ONE AREA L II 110CD PB -3 CIR-4A EOL FROM FREIGHT ELEVATOR PB -3 CIR-4B EOL REPLACE EXISTING SMOKE DETECTOR. NOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. Building Key: 8' 4 0 8' SCALE 1/8"=1-0" FIRE SYSTEM DEVICE LOCATIONS JCP 0696 1a JCPenney #0696 c Southcenter 0 3rd Floor Alarm Plans CI) PLI 1/8"=V-0" 1/11/2008 BW DLJ 12/5/2007 DLJ I 1 1/16/2008 DLJ 2 2/14/2008 DLJ 3 3/6/2008 Updated per JCP Rev 1 dated 1/11/2008 Updated per JCP Rev 2 dated 1/31/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. SHEET \O: 8 OF 10 Clr 4 <1)2#14 FPLP Clr 3 (1)2#14 FPLP Cir 2 <1)2#14 FPLP CII" 1 (1)2#14 FPLP Dedicated 120 VAC 20 Amp Circuit(Locked) SLC Loop Style 4 FireLite MS9600 DACT-UD (1)2#16 FPLP SLC Loop Style (1)2#16 FPLP FireLite BB -26F Battery 12V25AH Battery 12V25AH Phone Line 1 Phone Line 2 FS C1)4#18 FPLP FireLite BB -26F System Documentation As Built Drawings ® iMI Box Tampers Control Panel HVAC Shut Down [1 Jl JUUI JI Jl JI JUUI Rt O. ( O. 0. HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC Shut Shut Shut Shut Shut Shut Shut Shut Shut Shut Down Down Down Down Down Down Down Down Down Down Box Tampers Box Tampers PB -I PB -2 PB -3 PB -4 PB -5 PS Box Tampers 1W Recall Recall Shunt Fire Pr! Alt. Trip Hat EMS Light Control F I IGRF Recall Recall Shunt Flre Pr Alt Trip Hat HVAC Shut Down ALtronic AL4000LX Duct Detector Power FqikkrkiRic gic Ric Cir 4A <1) #14/2 Cir 3A ikrilkkrffic (1) #14/2 Cir 2A (1) #14/2 t G C L t t L C L (1) #14/2 Cir 4B CI) #14/2 Cir 3B 0 0 0 1:1 o 0 0 (1) #14/2 Cir 2B (1) #14/2 Cir 1 B 151c'R� 'Ati 'Xti (� gt (1) #14/2 Altronix 1002ULADA #1 Battery Gro�nd Dedicated 120 VAC 20 Amp Circuit(Locked) Cir 4A (1) #14/2 Cir 3A a (1) #14/2 Cir 2A C1) #14/2 ffilc t L t C L G t t r5lL Cir 1A (1) *14/2 (VOTES: 1. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING, AND CONSTRUCTION AS NEEDED PER AS -BUILT 2. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. 3. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. 4. COVERAGE AREA FOR ALL CEILING MOUNTED STROBE LIGHTS ARE BASED ON A CEILING HEIGHT OF 20 FEET. 5. HORNS AND STROBES ARE TO BE MOUNTED 80" ABOVE THE FINISHED FLOOR TO BOTTOM OF UNIT OR 6" DOWN FROM THE CEILING TO THE TOP OF THE UNIT, WHICHEVER IS LOWER. UNITS NOTED WITH A "C" ARE TO BE CEILING MOUNTED. 6. MANUAL PULL STATIONS ARE TO BE MOUNTED 48" ABOVE THE FLOOR TO THE TOP OF THE UNIT. 7. ALL DEVICES ARE TO BE MOUNTED ON BACK BOXES. 8. WIRE IS TO BE IN CONDUIT TO THE CEILING OR FISHED IN WALLS. 9 CONNECTIONS TO THE POWER SERVICE SHALL BE ON A DEDICATED BRANCH CIRCUIT. THE CIRCUIT AND CONNECTIONS SHALL BE MECHANICALLY PROTECTED THE POWER CIRCUIT SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL". THE LOCATION OF THE DISCONNECTING MEANS SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. Cir 4B k bsk Cl) #14/2 Cir 3B (1) #14/2 Cir 2B 0 0 0 0 0 0 0 E 13 CD #14/2 Cir 1 B ac 1-56 54c F5 (1) #14/2 Altronix 1002ULADA #2 Battery Gro�nd Dedicated 120 VAC 20 Amp Circuit(Locked) Ittl I>xi Ittl II Cir 4A CI) #14/2 Cir 3A Cl) #14/2 Cir 2A (1) #14/2 L G L t G G "t G L (1)C #14/2 Cir 4B I>xl I>xl Ittl Ittl (1) #14/2 Cir 3B (1) #14/2 Cir 28 <1) #14/2 0 0 0 0 0 0 0 0 0 6 0 6 Cir 1 B'rt " " ""t '"'t 'k CD #14/2 Altronix 1002ULADA #3 Battery Groilnd Fire ALarrm Leceno Dedicated 120 VAC 20 Amp Circuit(Locked) Symbol Qty Description Manufacture/Part Number Mounting Requirements lll.lr L Smog. Pnv1 r- Wiring 1 Fire Alarm Control Panel FireLite MS9600 W/DACT-UD Surface mounted enclosure provided Top 72" AFF conduit to ceiling Fop WJ1055 FC1010 1 Fire Alarm Annunciator Alpha Keypad FireLite LCD -80F Single or double Gang, 4" square box 60" AFF conduit to ceiling FSA WJ1088 LC150 SEALANT 6 Addressable Dual Monitor Module FireLite MDF300 4" square deep box MDF PVC CONDUIT 2" AND SMALLER CAJ2031 13 Addressable Monitor Module FireLite MMF300, MMF301 4" square deep box MMF CAJ2038 ®p 17 Smoke Detector Photo Electric FireLite 5D355 Single Gang, 3.5" Octagon or 4" Sq, Box In the ceiling ®R 9 Heat Detector R of R 135 deg or indicated Fire Lite H355R 3 1/4" Octagon box mounted in the ceiling CAJ2124 0 Manual Pull Station FireLite BG-12LX Deep Single Gang Box 48" AFF to Center, Conduit to ceiling P CAJ4029 25 Addressable Control Module FireLite CRF -300 4" square deep box CRF T,, D Duct Smoke Detector Photo Electric FireLite D350PL 1/2' Flex to 4" Square Box SSS100 SEALANT 25 Remote indicator Test/Reset FireLite RTS451KEY Single Gang Box Conduit to ceiling RI FIRESTOP MORTAR 9 4 Water Flow Switch Supplied by others 1/2' FLex to Deep 4" square box Conduit to ceiling S -2i 9 Sprinkler Valve Tamper Switch Supplied by others 1/2' FLex to Deep 4" square box Conduit to ceiling i- I -4 2 Air Pressure Switch Supplied by others 1/2' FLex to Deep 4" square box Conduit to ceiling 5 Signal Power Booster Altronix AL1002UL-ADA Surface mounted enclosure provided Top 72' AFF conduit to ceiling PB 4 Strobe Candella Indicated System Sensor SW or SWH Multi Candella Single or double Gang, 411 square box 80" AFF to bottom of box 77( 83 Ceiling Strobe Candella Indicated System Sensor SCW or SCWH Multi Candella Single or double Gang, 4" square box Mounted to the ceiling C 2 12 Horn Strobe Candella Indicated System Sensor P2W or P2WH Multi Candella Single or double Gang,' 4" square box 80" AFF to bottom of ' box g ffc 126 Ceiling Horn Strobe Candella Indicated System Sensor PC2W or PC2WH Multi Candella Single or double Gang, 4" square box Mounted to the Ceiling 1 Outdoor Horn Strobe Candella Indicated System Sensor P2RK Multi Candella Single or double Gang,' 411 square box 84" to 96' AFG to top of box Xt Wp 1 Auxilary Power Supply Altronix AL4000LX Surface mounted enclosure provided Top 72' AFF conduit -�o ceiling PS 2 Power Supervisory Relay A77 -716B 4" Square Box I Conduit to ceiling R 0 Isolator Module Firelite I300 411 square deep box ISO SLC Circuit ADT-454747ARE 16 Ga 2 Cond Shielded FPLP Annuclator Circuit ADT-454746ARE 18 Ga 6 Cond Shielded FPLP i Power Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Notification Circuits ADT-454719ARE 14 Ga 2 Cond FPLP Duct Detector Test Station ADT-474711ARE 18 Ga 4 Cond FPLP Device Wiring ADT-474711ARE 18 Ga 4 Cond FPLP 0 0 0 0 a> #14ir 4A2 Cir 3A gic Pc 5k k xriic Pc Pc Pc (1> #14/2 Cir 2A (1) #14/2 Cir 1A Supplied, Installed & Wired by JCI Supplied, Installed & Wired by JCI (1) #14/2 1 Cir 46 COffilc 171 [51 #14/2 Cir 3B C1) #14/2 Cir 28 (1) #14/2 Cir 16 ac k (1) #14/2 Altronix 1002ULADA #4 Battery Gro�nd kackk Dedicated 120 VAC 20 Amp Circuit(Locked) Wire Legend Cir 4A (1) #14/2 Cir 3A xrik k (1> #14/2 Cir 2A Cl) #14/2 t C L L (1) #14/2 _.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._ Notification Wiring - Fire Alarm Device Wiring "SPECSEAL PRODUCTS lll.lr L Smog. Pnv1 r- Wiring FIRE RATED PENETRATION SCHEDULE TYPE OF PENETRATION CONCRETE OR MASONARY GYPSUM BOARD/FRAME "SPECSEAL PRODUCTS FLOORS UL SYSTEM # WALLS UL SYSTEM # FLOORS UL SYSTEM # WALLS UL SYSTEM # METAL CONDUITS ANY SIZE CAJ1079 WJ1055 FC1010 WJ1049 SSS100 SEALANT CAJ1213 CAJ1213 WJ1088 LC150 SEALANT CAJ1198 CAJ1198 WL1062 PENS00 SILICONE PVC CONDUIT 2" AND SMALLER CAJ2031 WJ2018 FC2032 WL2093 SSS100 SEALANT PVC CONDUITS 2" THRU 4" CAJ2038 CAJ2038 FC2033 FC2029 FIRESTOP COLLAR CAJ2045 CAJ2045 FIRESTOP COLLAR CAJ2124 CAJ2124 FC2033 WL2059 WRAP STRIPS CABLE TRAY STEEL OR ALUMINUM CAJ4029 CAJ4029 WL4008 FIRESTOP PILLOWS CAJ4020 CA14020 FIRESTOP MORTAR CA14009 WL4005 SSS100 SEALANT ELECTRICAL BUS DUCT CAJ6009 CA16009 FIRESTOP MORTAR CAJ6008 CAJ6008 WL6001 SSS100 SEALANT MAX. 3" CABLE BUNDLES CAJ3133 WJ3022 FC3015 WL3076 SSS100 SEALANT NOTES; 1. ALL U.L. USTED SYSTEMS SHOWN ABOVE ARE BASED ON PROVIDING A 1 & 2 HOUR RATED FIRESTOP. WHERE 3 HOUR RATING IS REQUIRED, CONTACT FIRESTOP PRODUCT MANUFACTURER FOR DESIGN MODIFICATIONS. 2. ALL U.L. USTED SYSTEMS SHOWN ABOVE ARE BASED ON "SpecSeal Firestop" PRODUCTS FROM SPECIFIED TECHNOLOGIES, INC. OR APPROVED EQUAL PRODUCTS FROM "3—M" OR HILTI, INC. Devices mounted within 3' of starter motor NO/C/NC Interface Relay CRF300 SLC + Red SLC - Black NO/C/NC upplied by ADT Installed & Wired BY JCI ahelld wire Splice and Insulate, SLC Loop In & Out (2)2#16 FPLP Shielded 24VDC to Next JCI Relay or superviory - re SLCLoop To next device Note: All devices must be installed, connected and programed Into the fire alram system. Prior to connecting the 24VDC to the power supply in order to prevent the accidental shutdown of all HVAC systems. Duct work Duct detector Supplied & wired by ADT Installed by JCI Cir 48 (1) #14/2 Cir 38 (1) #14/2 Cir 2B (1) #14/2 Cir 16 (1) #14/2 Altronix 1002ULADA #5 Battery Ground SLC Loop From FCP or previous device 24VDC from Power supply or previous device Red + Black _ Dedicated 120 VAC 20 Amp Circuit(Locked) SCALE = NTS FIRE SYSTEM DEVICE LOCATIONS JCP 0696 O N N 1200 Southcenter cin Seattle, WA 98188 Diagram & Battery NTS 1/11/2008 - - - - -- ---- BW DLJ DLJ DLJ 2 DLJ 3 I I 1/16/2008 2/14/2008 3/6/2008 Updated per JCP Rev 1 dated 1/11/2008 Updated per JCP Rev 2 dated 1/31/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. SHEET NO: 9 OF 10 ---- ---------- ------------ JCPenney Standard Fire Alarm Zoning 0.000 0.000 Annunciate alarm signal at control panel and remote annunciator Annunciate supervisory signal at control pane and remote annunciator - FireLite MS9600 Reporting Zone # Address Number Device Software Zone Software Zone Software Zone Software Zone Software Zone All Devices Per Device NAC #1 System sensor Sync 1 2 0.170000 DACT-UD Dual Line Dialer 1 0.100000 0.100000 0.132000 NAC #2 System sensor Sync 1 2 0.064000 SD355 Smoke Detector Photo 17 0.000300 0.005100 0.000300 NAC #3 System sensor Sync 1 2 0.002700 MDF -300 Monitor Module Dual Input 6 0.000750 0.004500 0.000750 NAG #4 System sensor Sync 1 2 0.001530 MVS -301 Mantior Nodule Small 8 0.000375 0.003000 0.000375 Relay #1 Alarm 1 2 0.012750 0350P1. Duct Smoke Detector 25 0.000300 0.007500 0.000300 Relay #2 Trouble 4 0.000000 0.008000 0.200000 Voltage Drop for 14 AWG w ire 3.640 2.493 3.423 2.499 Voltage Drop= 2 • Wire Run Distance • 3.07 Ohms Fer 1000 ft 14 AWG " Total Current for Circuit / 1000 0.000000 Relay #3 Supervisory 3 0.276 Alarm 0.603 Air Pressure Low Signal Circuits Loop #1 Module Addresses x Alarm Current 8.159 Alarm Current Circuit 160 1 2 Box Tampers Control Box Tampers Battery Box 3 3 AL1002UL-AGA-J 0.175 0.000 Size Supplied 18 A.H. 1 161 163 4 Water flow #1 1 0.000 0.000 164 5 Sprinkler Tamper Switch #1 3 0.000 Circuit 2 AL1002UL-ADA-J 165 6 Water flow #2 1 Circuit IA Circuit 2A Circuit 3A 0.000 Max Wire Run Distance For AWG 14 668 792 166 7 Sprinkler Tamper Switch #2 3 x 0.000 Total 2 Wlaxiniim 2.5 Anps 167 8 Water flow #3 1 0.212 0.212 Standby Hours 60 168 9 Sprinkler Tamper Switch #3 3 Standby Amp Hrs 5.400 0.000 Smoke detectors 169 10 Sprinkler Tamper Switch #4 3 0.212 Circuit 4 170 11 Sprinkler Tamper Switch #5 3 Size Supplied 18A.H. I 0.000 171 12 Sprinkler Tamper Switch #6 3 x 0.000 Total 4 Maximum 2.5 Amps 172 13 Dry Water flow #1 1 x 0.212 x Circuit 1 Circuit 2 173 14 Dry Sprinkler Tamper Switch #1 3 3073 Actual Wire run Distance 174 15 Air Pressure Switch High 3 0.130 Voltage Drop = 2 * Wre Run Distance * 3.07 Ohms Par 1000 ft 14 AWG * Total Current for Circuit / 1000 175 16 Air Pressure Switch Low 1 x Standby Hours 60 176 17 Outside PIV #1 3 177 18 Outside PIV #2 3 178 19 Box Tampers Power Supply 3 Alarm Current 5 Mn 0.068 179 20 Box Tampers Power Expander #1 3 Passenger Elevator 180 21 Box Tampers Power Expander #2 3 and 20% Reserve 19.935 181 22 Box Tampers Power Expander #3 3 Smoke Detectors Battery Size Supplied 25 A.H. 182 23 Box Tampers Power Expander #4 3 183 24 Box Tampers Power Expander #5 3 Lower level lobby x 233 74 EMS Light control 1 2 x 236 77 Freight Elevator#1 shunt trip 10 Upper level lobby x 237 78 Freight Elevator #1 Level 1 Recall 11 x 238 79 Freight Elevator #1 Level 2 Recall 12 x Machine room 239 80 Freight Elevator #1 Fire Hat 13 240 81 Passenger Elevator #1 shunt trip 20 x x 241 82 Passenger Elevator #1 Level 1 Recall 21 x 242 83 Passenger Elevator #1 Level 2 Recall 22 x x x 243 84 Passenger Elevator #1 Fire Hat 23 244 85 Passenger Elevator #2 shunt trip 30 245 86 Passenger Elevator #2 Level 1 Recall 31 x 246 87 Passenger Elevator#2 Level 2 Recall 32 x x x x 247 88 Passenger Elevator #2 Fire Hat 33 x 252 93 HVAC #1 Shutdown 41 x x x x 253 94 HVAC #2 Shutdown 42 x x 254 95 HVAC #3 Shutdown 43 x x x 255 96 HVAC #4 Shutdown 44 256 97 HVAC #5 Shutdown 45 257 98 HVAC #6 Shutdown 46 Freight Bevator 258 99 HVAC #7 Shutdown 47 259 100 HVAC #8 Shutdown 48 Smoke detectors 260 101 HVAC #9 Shutdown 49 261 102 HVAC #10 Shutdown 50 Lower level lobby x 262 103 HVAC #11 Shutdown 51 x 263 104 HVAC #12 Shutdown 52 x Upper level lobby 272 113 EOL Power Supervision MMF 61 x 273 114 EOL Power Supervision MMF 62 x x Machine room x Detector Addresses x 001 1 Smoke Detector at panel 2 x x x 002 2 Smoke Detector at Penthouse 2 x 021 21 AHU #1 Supply Duct Detector 3 41 x x x 022 22 AHU #1 Return Duct Detector 3 41 023 23 AHU #2 Supply Duct Detector 3 42 024 24 AHU #2 Return Duct Detector 3 42 x 025 25 AHU #3 Supply Duct Detector 3 43 x x x 026 26 AHU #3 Return Duct Detector 3 43 x 027 27 AHU #4 Supply Duct Detector 3 44 x x x 028 28 AHU #4 Return Duct Detector 3 44 x 029 29 AHll #5 Supply Duct Detector 3 45 x x 030 30 AHU #5 Return Duct Detector 3 45 031 31 AHU #6 Supply Duct Detector 3 46 032 32 AHU #6 Return Duct Detector 3 46 Abnormal circuit or device 033 33 AHU #7 Supply Duct Detector 3 47 034 34 AHU #7 Return Duct Detector 3 47 035 35 AHU #8 Supply Duct Detector 3 48 036 36 AHU #8 Return Duct Detector 3 48 037 37 AHU #9 Supply Duct Detector 3 49 038 38 AHU #9 Return Duct Detector 3 49 039 39 AHU #10 Supply Duct Detector 3 50 040 40 AHU #10 Return Duct Detector 3 50 041 41 AHU #11 Supply Duct Detector 3 51 042 42 AHU #11 Return Duct Detector 3 51 043 43 AHU #12 Supply Duct Detector 3 52 044 44 AHU #12 Return Duct Detector 3 52 065 65 Freight Elev Heat Detector Pit 2 10 066 66 Freight Elev Heat Detector Machine Room 2 10 067 67 Freight Elev Smoke Detector Machine Room 2 12 068 68 Freight Elev Smoke Detector 1st floor Lobby 2 12 069 69 Freight Elev Smoke Detector 2nd floor Lobby 2 11 071 71 Freight Elev Smoke Detector 3rd floor Lobby 2 11 072 72 Freight Elev Smoke Detector Top of shaft 2 11 073 73 Freight Elev Heat Detector Top of Shaft 2 10 076 76 Passenger Elev#1 Heat Detector Pit 2 20 077 77 Passenger Elev#1 Heat Detector Machine Room 2 20 078 78 Passenger Elev#1 Smoke Detector Machine Room 2 22 079 79 Passenger Elev#1 Smoke Detector Main floor Lobby 2 22 080 80 Passenger Elev#1 Smoke Detector 2nd floor Lobby 2 21 082 82 Passenger Elev#1 Smoke Detector 3rd floor Lobby 2 21 083 83 Passenger Elev#1 Smoke Detector Top of shaft 2 21 084 84 Passenger Elev#1 Heat Detector Top of Shaft 2 20 087 87 Passenger Elev#2 Heat Detector Pit 2 30 088 88 Passenger Elev#2 Heat Detector Machine Room 2 30 089 89 Passenger Elev#2 Smoke Detector Machine Room 2 32 090 90 Passenger Elev#2 Smoke Detector Main floor Lobby 2 32 091 91 Passenger Elev#2 Smoke Detector 2nd floor Lobby 2 31 093 93 Passenger Elev#2 Smoke Detector 3rd floor Lobby 2 31 094 94 Passenger Elev#2 Smoke Detector Top of shaft 2 31 095 95 Passenger Elev#2 Heat Detector Top of Shaft 2 30 Part Number AL400ULX Standby Battery Calculations Altronix AL4000LX JCPenney Seattle. WA 98188 Description Quantity Flower Supply 4A ©12 or 3A ©24VC 1 Standby Current Alarm Current For Device All Devices Per Device All Devices 0.060 0.060 0.060 0.060 Auxiliary devices Maximum 3 Amps A77 -716B Pow er Supervisory Relay Total Aux current 2 0.019 0.038 0.000 Max 3 An-ps 0.098 Standby Hours Standby Battery Draw Standby Arrp Its 24 0.098 2.352 Alarm Current Alarm Current 5 Mn 0.098 0.008 Battery Size Required with 5 Mn. Alarm Time and 20% Reserve 2.832 Battery Size Supplied 7 A.H. 0.019 0.038 0.000 Alarm 0.098 Sequence of Operation Standby Battery Calculations FireLite MS9600 JCPenney 0.000 0.000 Annunciate alarm signal at control panel and remote annunciator Annunciate supervisory signal at control pane and remote annunciator Seattle, WA 98188 Transmits alarm signal to UL fisted monitoring center Transmits supervisory signal to UL listed monitoring center Transmits trouble to UL fisted monitoring center. Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All Devices MS9600 Fire Alarm Control 1 0.120000 0.120000 0.170000 0.170000 DACT-UD Dual Line Dialer 1 0.100000 0.100000 0.132000 0.132000 LCD -80F Annunciator LCD 1 0.025000 0.025000 0.064000 0.064000 SD355 Smoke Detector Photo 17 0.000300 0.005100 0.000300 0.005100 I -1355R Heat Detector Rate of Rise 9 0.000300 0.002700 0.000300 0.002700 MDF -300 Monitor Module Dual Input 6 0.000750 0.004500 0.000750 0.004500 MMF-300 Nbnitor Module Single input 3 0.000400 0.001200 0.000510 0.001530 MVS -301 Mantior Nodule Small 8 0.000375 0.003000 0.000375 0.003000 CRF -300 Control Module Relay 25 0.000270 0.006750 0.000510 0.012750 0350P1. Duct Smoke Detector 25 0.000300 0.007500 0.000300 0.007500 RTS451 KEY Remote test Sw itch 25 0.000000 0.000000 0.008000 0.200000 Voltage Drop for 14 AWG w ire 3.640 2.493 3.423 2.499 Voltage Drop= 2 • Wire Run Distance • 3.07 Ohms Fer 1000 ft 14 AWG " Total Current for Circuit / 1000 0.000000 0.000000 Circuit 3A Total Aux current Max 3 Amps 0.276 Alarm 0.603 Air Pressure Low Signal Circuits Standby Anp Hrs 5.400 0.000 x Alarm Current 8.159 Alarm Current Circuit Device Quantity Per Device All Devices Circuit 1 AL1002UL-AGA-J 0.175 0.000 Size Supplied 18 A.H. 1 I (Battery Size Supplied 18 A.H. 0.000 0.000 0.000 0.000 Circuit 46 0.000 Total 1 Maximum 2.5Amps 0.000 Circuit 2 AL1002UL-ADA-J 0.175 0.000 Totals Maximum 10 Amps v x Circuit IA Circuit 2A Circuit 3A 0.000 Max Wire Run Distance For AWG 14 668 792 Actual Wire run Distance 450 375 0.000 x x x 0.000 Total 2 Wlaxiniim 2.5 Anps Actual Wire run Distance 400 400 0.000 Circuit 3 P2RK-110 1 0.212 0.212 Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. 0.000 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 0.000 Smoke detectors 0.000 Total 3 Maximum 2.5Arms 0.212 Circuit 4 Battery Size Required w ith 5 Mn. Alarm Time and 20% Reserve 6.817 0.000 Size Supplied 18A.H. I 0.000 at panel 0.000 x 0.000 Total 4 Maximum 2.5 Amps 0.000 Totals Maximum 6Amps- x 0.212 x Circuit 1 Circuit 2 Circuit 3 Circuit 4 Max Wire Run Distance For AWG 14 3073 Actual Wire run Distance 100 Voltage Drop for 14 AWG w ire 0.130 Voltage Drop = 2 * Wre Run Distance * 3.07 Ohms Par 1000 ft 14 AWG * Total Current for Circuit / 1000 Duct smoke detectors x Standby Hours 60 x Standby Battery Draw 0.276 Standby Amp Hrs 16.545 Alarm Current 0.815 Alarm Current 5 Mn 0.068 Passenger Elevator Battery Size Required with 5 Mn. Alarm Time and 20% Reserve 19.935 Smoke Detectors Battery Size Supplied 25 A.H. Part Number AL400ULX Standby Battery Calculations Altronix AL4000LX JCPenney Seattle. WA 98188 Description Quantity Flower Supply 4A ©12 or 3A ©24VC 1 Standby Current Alarm Current For Device All Devices Per Device All Devices 0.060 0.060 0.060 0.060 Auxiliary devices Maximum 3 Amps A77 -716B Pow er Supervisory Relay Total Aux current 2 0.019 0.038 0.000 Max 3 An-ps 0.098 Standby Hours Standby Battery Draw Standby Arrp Its 24 0.098 2.352 Alarm Current Alarm Current 5 Mn 0.098 0.008 Battery Size Required with 5 Mn. Alarm Time and 20% Reserve 2.832 Battery Size Supplied 7 A.H. 0.019 0.038 0.000 Alarm 0.098 Sequence of Operation Auxiliary devices Maximum 3 Amps 0.000 0.000 Annunciate alarm signal at control panel and remote annunciator Annunciate supervisory signal at control pane and remote annunciator Annunciate trouble signal at control pane and remote annunciator Transmits alarm signal to UL fisted monitoring center Transmits supervisory signal to UL listed monitoring center Transmits trouble to UL fisted monitoring center. Shuts down associated AHU/RTU 0.000 N Activate elevator shunt trip Release Security Gate Release Office Door Strikes Turn on Lights through EMS Light Control g Water flow x Circuit 2A FC2WH-177 2 0.290 0.580 1 1 i 41 i 4 Circuit 26 PC2WH-177 4 0.290 1.160 0.000 0.000 ch 11. 4 Sprinkler system Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device Al Devices Circuit 1A PC2W-30 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 1.031 Circuit 16 FC2W-30 7 0.107 0.749 SON --30 3 0.094 0.282 0.000 0.000 Water flow x Circuit 2A FC2WH-177 2 0.290 0.580 FC2W-75 1 0.176 0.176 x SCWH-177 1 0.281 0.281 1.131 Circuit 26 PC2WH-177 4 0.290 1.160 0.000 0.000 0.000 x x x x x 0.000 Valve tamper Circuit 3B FC2W--75 4 0.176 0.704 x 0.000 0.000 x Total3 Maximum 2.5 Amps I 2.151 Circuit 4A P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 I 0.000 0.000 0.740 Circuit 4B P2W75 3 0.176 0.528 P2W-110 1 0.212 0.212 0.000 0.000 0.740 Air Ressure High Totals Maximum 10 Amps 7.984 x Max Wre Run Distance For AWG 14 632 576 714 880 Actual Wire run Distance 550 475 450 550 x Circuit 1B Circuit 26 Circuit 3B Circuit 4B Max Wre Run Distance For AWG 14 632 562 526 880 Actual Wre run Distance 575 350 450 550 Voltage Drop for 14 AWG w ire 3.640 2.493 3.423 2.499 Voltage Drop= 2 • Wire Run Distance • 3.07 Ohms Fer 1000 ft 14 AWG " Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts 1.363 Circuit 3A Standby Hours 60 and a minimum voltage at the end of line of 16 Vons. Standby Battery Draw 0.090 Air Pressure Low x Standby Anp Hrs 5.400 0.000 x Alarm Current 8.159 Circuit 3B Alarm Current 5 Mn 0.677 Alarm Current 5 Mn 0.769 x x x x x Size Supplied 18 A.H. 1 I (Battery Size Supplied 18 A.H. 0.000 0.000 0.000 0.000 Circuit 46 0.000 0.000 0.000 i Manual pull station x 0.000 Totals Maximum 10 Amps v x Circuit IA Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 668 792 Actual Wire run Distance 450 375 x x x x Max Wire Run Distance For AWG 14 749 1206 Actual Wire run Distance 400 400 Voltage Drop for 14 AWG w ire 2.137 1.326 Voltage Drop = 2 • Wre Run Distance • 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Smoke detectors Alarm Current 3.383 •Alarm Current 5 Mn 0.281 Battery Size Required w ith 5 Mn. Alarm Time and 20% Reserve 6.817 'Battery Size Supplied 18A.H. I at panel x x x x x x Duct smoke detectors x x x Passenger Elevator Smoke Detectors Lower level lobby x x x x x x x Upper level lobby x x x x x x x Machine room x x x x x x x Top of shaft x x x x x x x Heat Detector Top of shaft x x x x x x x Machine room x x x x x x x Bottom of shaft x x x x x x x Freight Bevator Smoke detectors Lower level lobby x x x x x x x Upper level lobby x x x x x x x Machine room x x x x x x x Top of shaft x x x x x x x Heat Detector Top of shaft x x x x x x x Machine room x x x x x x x Bottom of shaft x x x x x x x Abnormal circuit or device x x System Outline Location JCFanney 0696-5 1200 Southcenter Man Seattle, WA 98188 II. Codes A. 2002 NFPA 72 Chapters 1-10 as Applcable(Rerrote Station) B. 2002 NEC, Articles 250, 725, 760 C. Local, City, State III. Control A. B. C. D. 1 MS9600 1 DACT UD 5 AL1002UL-ADA-J 1 AL4000LX N. Fire Alarm Initiating Devices A. 1 17 9 25 4 9 2 B. C. D. E F. G. BG-12LX S0355 H355R D350PL Water Flow Tapper Sw itch Air Pressure V. Fire Alarm Indicating Devices A. 1 LCD -80F B. C. D. E F. G. H J. K. L. M N. O. P. Q. 46 5 27 46 3 2 6 4 4 8 18 44 9 2 2 1 PC2WH-177 FC2W:-115 Fc2W-75 FC2W-30 FC2W-15 P2W-110 P2W-75 P2W-30 SCW-I-177 SCW-115 SCW-75 SOW -30 SOW -15 SW -30 SW -15 P2RK-110 VI. Zones All devices are addressable with there own address 1-159 detector addresses 1-159 module addresses SLC Loop is style 4 VII. Wring Ore Alarm Control Dual Line Dialer ADA Flower Booster 10A@24VDC Fbwer Supply 4A @ 12 or 3A @ 24VDC Manual Pull Station Addressable Smoke Detector Photo Heat Detector Rate of Rise Duct Smoke Detector Connection Only, Rovided by Others Connection Only, Rovided by Others Connection Only, Provided by Others Annunciator LCD Ceiling Horn strobe white 24VDC 177CD Ceiling Horn strobe white 24VDC 115CD Ceiling Horn strobe white 24VDC 75CD Ceiling Horn strobe white 24VDC 30CD Ceiling Horn strobe white 24VDC 15CD Wall Horn strobe white 24VDC 110CD Wall Horn strobe white 24VDC 75CD Wall Horn strobe white 24VDC 30CD Ceiling Strobe white 24VDC 177CD Ceiling Strobe white 24VDC 115CD Ccling Strobe white 24VDC 75CD eiling Strobe white 24VDC 30a) Ceiling Strobe white 24VDC 15CD Wall Strobe white 24VDC 30CD Wall Strobe white 24VDC 15CD Wall Horn strobe RED 24VDC Weather Roof All Circuits and Wring Shall be "Pow er Limited" SLC Circuits Shall be 16/2 Shielded U.L. FPLP Cable Initiating Zones Shall be 18/2 or 18/4 U.L. FPLP Cable Indicating Circuits Shall be 14/2 U.L. FPLP Cable System Ground Shall be 14 THWN Green Conductor Under Ground and Outside Wire shall be 14 Tl -WN in Approved Raceway VIII. Listings A. All Equipment Shall Be U.L. Listed and Compatible IX. Paw er Supply A. Primary - 110 VAC Dedicated 20 Amp Circuit B. Secondary - 25 Amp Hour Battery X. Alarm Supervision A. Human B. Remote Station ADT Fre & Security 14200 E Exposition Blvd. Aurora, CO 80012 (303) 338-8200 S994-183 WFX Installing Branch/Contractor ADT Tyco Fire & Security 11824 No Creek Parkway Bothell, WA 98011 (206) 624-3103 Standby Battery Calculations Altronix AL1002ULADA #3 JCPenney Seattle, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device Al Devices Per Device Al Devices AL1002UL-ADA-J ADA Power Booster 10A@24VIJC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device Al Devices Circuit 1A PC2W-30 7 0.107 0.749 SCW-30 3 0.094 0.282 0.000 0.000 1.031 Circuit 16 FC2W-30 7 0.107 0.749 SON --30 3 0.094 0.282 0.000 0.000 1.031 Total 1 Maxirrum 2.5 Anps 2.062 Circuit 2A FC2WH-177 2 0.290 0.580 FC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 SCWH-177 1 0.281 0.281 1.131 Circuit 26 PC2WH-177 4 0.290 1.160 0.000 0.000 0.000 1.160 Total2 Maximum 2.5 Amps 2.291 Circuit 3A FC2W-75 2 0.176 0.352 PC2W-30 4 0.107 0.428 SCW-15 2 0.066 0.132 0.000 0.912 Circuit 3B FC2W--75 4 0.176 0.704 FC2W-30 5 0.107 0.535 0.000 0.000 I 1,239 Total3 Maximum 2.5 Amps I 2.151 Circuit 4A P2W-75 3 0.176 0.528 P2W-110 1 0.212 0.212 I 0.000 0.000 0.740 Circuit 4B P2W75 3 0.176 0.528 P2W-110 1 0.212 0.212 0.000 0.000 0.740 Total 4 Maximum 2.5 Amps 1.480 Totals Maximum 10 Amps 7.984 i Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wre Run Distance For AWG 14 632 576 714 880 Actual Wire run Distance 550 475 450 550 Voltage Drop for 14 AWG w ire 3.482 3.299 2.520 2.499 Circuit 1B Circuit 26 Circuit 3B Circuit 4B Max Wre Run Distance For AWG 14 632 562 526 880 Actual Wre run Distance 575 350 450 550 Voltage Drop for 14 AWG w ire 3.640 2.493 3.423 2.499 Voltage Drop= 2 • Wire Run Distance • 3.07 Ohms Fer 1000 ft 14 AWG " Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts 1.363 Circuit 3A Standby Hours 60 and a minimum voltage at the end of line of 16 Vons. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line, Standby Anp Hrs 5.400 0.000 Alarm Current 8.159 Circuit 3B Alarm Current 5 Mn 0.677 Alarm Current 5 Mn 0.769 0.000 Battery Size Required with 5 Mn. Alarm Trine and 20% Reserve 7.293 'Battery Battery Size Required with 5 Mn. Alarm lime and 20% Reserve 7.403 0.000 Size Supplied 18 A.H. 1 I Standby Battery Calculations Altronix AL1002ULADA #1 JCPenney Seattle, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All Devices AL1002UL-ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Auxikary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device Al Devices Circuit 1A PC2W-30 2 0.107 0.214 SCW-30 4 0.094 0.376 PC:2W-75 1 0.176 0.176 PC2WH-177 2 0.290 0.580 1.346 Circuit 16 FC2W-75 3 0.176 0.528 SCW-75 2 0.158 0.316 PCW -30 2 0.107 0.214 0.000 1.058 Total 1 Maximum 2.5 Anps 2.404 Circuit 2A FC2WH-177 3 0.290 0.870 PC2W-115 1 0.218 0.218 SCW-75 1 0.158 0.158 0.000 1.246 Circuit 26 PC2Wi-177 3 0.290 0.870 FC2W-115 1 0.218 0.218 0.000 0.000 1.088 Total 2 Maximum 2.5 Amps 2.334 Circuit 3A FC2Wi-177 3 0.290 0.870 SOW -115 1 0.210 0.210 SCW-75 1 0.158 0.158 0.000 1.238 Circuit 3B SCW-30 3 0.094 0.282 PCW -30 1 0.107 0.107 FC2W-75 2 0.176 0.352 FC2WH-177 1 0.290 0.290 1.031 Total 3 Ntaxirrum 2.5 Amps 2.269 Circuit 4A FC2W -177 2 0.290 0.580 SCW-115 1 0.210 0.210 F'C2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 1.060 Circuit 46 SCW-30 1 0.094 0.094 Fc2W-30 1 0.107 0.107 PC 2W--75 2 0.176 0.352 SCW-75 3 0.158 0.474 1.027 Total 4 Maximum 2.5 Amps 2.087 Totals Maximum 10 Anps 9.094 Circuit 1A Circuit 2A Circuit 3A Circuit 4A ' Max Wre Run Distance For AWG 14 484 523 526 615 Actual Wre run Distance 375 400 350 375 Voltage Drop for 14 AWG w ire 3.099 3.060 2.660 2.441 Circuit 1B Circuit 28 Circuit 3B Circuit 4B Max Wre Run Distance For AWG 14 616 599 632 634 Actual Wire run Distance 525 300 550 550 Voltage Drop for 14 AWG w ire 3.410 2.004 3.482 3.468 Voltage Drop = 2 • Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts 1.363 Circuit 3A Standby Hours 60 and a minimumvoltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 0.000 0.000 Circuit 3B Alarm Current 9.269 Alarm Current 5 Mn 0.769 0.000 0.000 Battery Size Required with 5 Mn. Alarm lime and 20% Reserve 7.403 0.000 Circuit 4A I (Battery Size Supplied 18 A.H. 0.000 Standby Battery Calculations Altronix AL1002ULADA #4 JCPenney Seattle, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device Al Devices Per Device All Devices AL1002UL-ADA-J ADA Power Booster 10A(4/24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device Al Devices Circuit 1A SCWH-177 1 0.281 0.281 SCW-75 2 0.158 0.316 SCW-30 3 0.094 0.282 PC2W-115 1 0.218 0.218 1.097 Circuit 16 FC2WH-177 4 0.290 1.160 0.000 0.000 0.000 1.160 Total 1 Maximum 2.5 Amps 2.257 Circuit 2A PC2WH-177 1 0.290 0.290 PC2W--30 2 0.107 0.214 SCW-115 1 0.210 0.210 PC2W-115 1 0.218 0.218 0.932 Circuit 26 PC2WH-177 3 0.290 0.870 SCW-115 1 0.210 0.210 PC2W-30 1 0.107 0.107 0.000 1.187 Total2 Maximum 2.5 Anus 2.119 Circuit 3A PC2WH-177 1 0.290 0.290 SCW-115 1 0.210 0.210 PC2W--75 2 0.176 0.352 0.852 Circuit 3B FC2WH-177 3 0.290 0.870 PC2W-75 1 0.176 0.176 0.000 1.046 Total 3 Maximum 2.5 Amps 1.898 Circuit 4A PC2WH-177 1 0.290 0.290 SCW-115 1 0.210 0.210 Fc2W-75 1 0.176 0.176 SCWV-30 3 0.094 0.282 0.958 Circuit 46 SCW-115 1 0.210 0.210 SCW-15 2 0.066 0.132 SCW-30 1 0.094 0.094 SCW-75 1 0.158 0.158 PC2W-75 1 0.176 0.176 Fc2WH-177 1 0.290 0.290 1.060 Total 4 Maximum 2.5 Anps 2.018 Totals Maximum 10 Amps - - 8.292 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wre Run Distance For AWG 14 594 699 765 680 Actual Wire run Distance 550 450 425 550 Voltage Drop for 14 AWG w ire 3.705 2.575 2.223 3.235 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wire Run Distance For AWG 14 562 549 623 615 Actual Wre run Distance 425 425 425 500 Voltage Drop for 14 AWG w ire 3.027 3.097 2.730 3.254 Voltage Drop = 2 • Wire Run Distance • 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts 1.363 Circuit 3A Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Anp Hrs 5.400 0.000 0.000 Circuit 3B Alarm Current 8.467 Alarm Current 5 Mn 0.703 0.000 0.000 Battery Size Required with 5 Mn. Alarm -firm and 20% Reserve 7.323 0.000 Circuit 4A I (Battery Size Supplied 18 A.ti 0.000 Standby Battery Calculations Altronix AL1002ULADA #2 JCPenney Seattle, WA 98188 Standby Current Alarm Current Part Number Description Quantity Per Device All Devices Per Device All Devices AL1002UL-ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 0.175 0.175 Auxiliary devices Maximum 3 Amps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Anps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device Al Devices Circuit 1A SCW-30 5 0.094 0.470 SCW-75 1 0.158 0.158 FC2W-30 1 0.107 0.107 PC2W-75 1 0.176 0.176 SCW-15 1 0.066 0.066 I SCW-115 1 0.210 0.210 1.187 Circuit 16 PC2WH-177 1 0.290 0.290 SCW-30 2 0.094 0.188 SCW-15 1 0.066 0.066 SCW-75 2 0.158 0.316 0.860 Total 1 Maximum 2.5 Arrps 2.047 Circuit 2A SCW-30 4 0.094 0.376 PC2W-30 2 0.107 0.214 SCW-75 1 0.158 0.158 0.748 Circuit 26 PC2W-30 1 0.107 0.107 SW -30 2 0.094 0.188 P2W-30 4 0.107 0.428 SW -15 2 0.066 0.132 0.855 Total 2 Maximum 2.5 Amps 1.603 Circuit 3A PC2WH-177 3 0.290 0.870 PC2W-75 1 0.176 0.176 SCW-30 1 0.094 0.094 0.000 1.140 Circuit 3B SCWH-177 2 0.281 0.562 PC2W-115 1 0.218 0.218 PC2WH-177 2 0.290 0.580 0.000 1.360 Total 3 Maximum 2.5Anps 2.500 Circuit 4A PC2WH-177 4 0.290 1.160 0.000 0.000 1.160 Circuit 46 PC2WH-177 2 0.290 0.580 PC2W-30 3 0.107 0.321 SCW-75 1 0.158 0.158 0.000 1.059 Total 4 Maximum 2.5 Amps 2.219 Totals Maximum 10 Anps 8.369 Circuit 1A Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 549 871 571 562 Actual Wre run Distance 425 525 425 350 Voltage Drop for 14 AWG w ire 3.097 2.411 2.975 2.493 Circuit 1B Circuit 2B Circuit 3B Circuit 4B Max Wre Run Distance For AWG 14 758 762 479 615 Actual Wire run Distance 400 500 350 525 Voltage Drop for 14 AWG w ire 2.112 2.625 2.923 3.414 Voltage Drop = 2 • Wre Run Distance • 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts 1.363 Circuit 3A Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 0.000 0.000 Circuit 3B Alarm Current 8.544 Alarm Current 5 Nin 0.709 0.000 0.000 Battery Size Required with 5 Mn. Alarm Time and 20% Reserve 7.331 0.000 Circuit 4A I 'Battery Size Supplied 18 A.H. 0.000 Standby Battery Calculations Altronix AL1002ULADA #5 JCPenney Seattle, WA 98188 Standby Current Part Number Description Quantity Per Device Al Devices AL1002UL-ADA-J ADA Power Booster 10A@24VDC 1 0.090 0.090 Alarm Current Per Device All Devices 0.175 0.175 Auxiliary devices Maximum 3 Arps 0.000 0.000 0.000 0.000 Total Aux current Max 3 Amps 0.090 Alarm 0.175 Signal Circuits Alarm Current Circuit Device Quantity Per Device Al Devices Circuit 1A PC2W-30 5 0.107 0.535 SCW-30 3 0.094 0.282 SCW-75 1 0.158 0.158 0.000 0.975 Circuit 1B FC2W-30 1 0.107 0.107 FC2W-15 1 0.079 0.079 PC2W-75 1 0.176 0.176 SCW-30 4 0.094 0.376 SCW-15 2 0.066 0.132 0.870 Total 1 Maximum 2.5 Amps 1.845 Circuit 2A PC2W-30 1 0.107 0.107 PC2W-75 1 0.176 0.176 PC2W-15 2 0.079 0.158 SCW 15 1 0.066 0.066 SCW-75 2 0.158 0.316 0.823 Circuit 26 PC2W-75 2 0.176 0.352 SON -30 2 0.094 0.188 0.000 0.000 0.540 Total 2 Maximum 2.5 Anps 1.363 Circuit 3A 0.000 0.000 0.000 0.000 0.000 Circuit 3B 0.000 0.000 0.000 0.000 Total 3 Maximum 2.5 Anps 0.000 Circuit 4A 0.000 0.000 0.000 0.000 0.000 Circuit 46 0.000 0.000 0.000 i 0.000 Total 4 , Maximum 2.5 Amps 0.000 Totals Maximum 10 Amps v 3.208 Circuit IA Circuit 2A Circuit 3A Circuit 4A Max Wire Run Distance For AWG 14 668 792 Actual Wire run Distance 450 375 Voltage Drop for 14 AWG w ire 2.694 1.895 Circuit 16 Circuit 28 Circuit 38 Circuit 46 Max Wire Run Distance For AWG 14 749 1206 Actual Wire run Distance 400 400 Voltage Drop for 14 AWG w ire 2.137 1.326 Voltage Drop = 2 • Wre Run Distance • 3.07 Ohms Per 1000 ft 14 AWG • Total Current for Circuit / 1000 Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 60 and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.090 Calculations assume that all devices are at the end of the line. Standby Amp Hrs 5.400 Alarm Current 3.383 •Alarm Current 5 Mn 0.281 Battery Size Required w ith 5 Mn. Alarm Time and 20% Reserve 6.817 'Battery Size Supplied 18A.H. I SCALE = NTS FIRE SYSTEM DEVICE LOCATIONS JCP 0696 1200 Southcenter os W 00 co CO Seattle, WA Calculations NTS 1/11/2008 BW DLJ DLJ 1 1/16/2008 DLJ 2 2/14/2008 DLJ 3 3/6/2008 Updated per JCP Rev 1 dated 1/11/2008 Updated per JCP Rev 2 dated 1/31/2008 Updated per Walkthrough. Removed Pull, added Riser Devices. Added Duct Detectors per Walkthrough. SHEET \O: 10 OF 10 RETAIL SALES AREA min NO WOjZK I I � E E E 0 E• R O R lO Ft O E 0 E R - R 1 1 i O E O E E. STOCK ROOM AREA E O+ E NEW WALL (TYPICAL) O E I ( I MATCHLINE 'I I I NMI NM IMINI IMO EMI 'MI • PLAN NOTES 1. SYSTEM DESIGNED PER N.F.P.A. #13 STANDARDS. 2. THE EXISTING SYSTEM IS A WET PIPE SYSTEM IN A RETAIL STORE 3. SCOPE OF WORK IS TO ADD AND RELOCATE SPRINKLERS AS SHOWN FOR NEW WALL. 4. SPRINKLER SPACING NOT TO EXCEED 130 SQ FT PER HEAD. 5. ORDINARY HAZARD OCCUPANCY - MERCANTILE 6. THE EXISTING DECK IS CONCRETE. 7. EXISTING BUILDING HAS SPRINKLER COVERAGE THROUGHOUT. 8. ALL SYSTEM COMPONENTS U.L. LISTED AND/OR F.M. APPROVED. 9. PIPE TYPE SHALL BE BLACK SCH-40 WITH BCI FITTINGS oA A - NEW HEAD TO BE ADDED - 12 o/\:, R - HEAD TO BE RELOCATED - 14 ❑ Without Comments ❑ As Noted in Red w Per The Attached Letter ee plans have been reviewed by The Tukwila Fire ention Bureau for conformance with current City (dards. Acceptance is subject to errors and L cions which do not authorize violations of adopted «dards and ordInarices. The responsibility for the :quaCy of desigli rens totally with the designer. ,iitions, deletions or:•l;,svisions to these drawings after :5 date will void tots :,cceptance and will require a :submittal of revised drawings for subsequent approval. 'final acceptance is suoject to field test and Inspection by i ne Tukwila Fire Prevention Bureau. Date: 7-/"/ By: 1 I 1 EXISTING 12'-0' CEILINGS THROUGHOUT rUK1ILA FIRE DEPARTMENT Incase call 206-575-4407 and $ve this Fire Permit No. 3 r.� act address for shut- or hutor restarAtori epproval. v///t ///////.r //%! ///�/////. //L,// //'7//.2//x/////// //I///. E E E 7 // R 41 E E E E E 0 E R E PARTIAL BASEMENT REFLECTED CEILING PLAN SCALE: 1/8"=1'-0" DETAIL A: FLEX HEAD DETAIL 1W BRANCHLINE� FLEX HEAD ASSEMBLY SPRINKLER HEAD HANGER DETAIL Concrete Anchor HILTI HDI HILTI HDI Anchor / (D n1e1 d) , / /� Construction All Thread Rod IIII Swivel Ring J Pipe CONCRETE DECK • f EXISTING 1'/2" BRANCH LINE RELOCATED HEAD CEILING @ 12'-0" FLOOR 1" DROP TO NEW SPRINKLER HEAD NEW WALL PARTIAL SECTION NO SCALE AREA OF CONSTRUCTION aft KEY PLAN BASEMENT LEVEL PAID JUL 31 2014 TUKWILA FIRE CG /-?P3/ WASHINGTON STATE CERTIFICATESNKLREYTFIE PROTECTION PRIESSEMS Keith Millard d' 6793-0492-C Level 3 • Reliance Fire Protection, Inc. N RRELIAAF`FP102L1 / rlof NOTES Legend Revisions Sprinkler Legend Symbol Description Revision No. Description Symbol Manufacturer Model FINISH K Factor Degree Qty. 2 WAY EQ BRACE TYCO TY L RECESSED STANDARD RESPONSE CHROME 5.6 165 12 4 WAY EQ BRACE RIGID GROOVED COUPLING r'/�!/f7011f! EXISTING PIPE TO BE DEMOED NEW SPRINKLER PIPING 444, EXISTING SPRINKLER PIPING HANGER LOCATION CONTRACTOR'S LICENSE: Lic. # RELIAFP 102L1 Job No.: S 07054 Date: July 2014 Reliance Fire Protection Inc., Tel: (206) 682-6636 PO Box 428 Fax: (2061 eith r 744 liar Preston, WA 98050 e-mail: keith@reliancefire.com Drawn by: Keith Millard Approval: TUKWILA FIRE DEPARTMENT Scale: AS SHOWN JC PENNEY # 696 WESTFIELD SOUTHCENTER 1249 SOUTHCENTER MALL TUKWILA, WA 98188 SHEET # FP 01 FIRE PROTECTION 0 F -- U In 1 w z z w 0 D 0 0 E 0 0 0 0 I. In Projects 2006\FCNW\JC Penney — Q) C D 0 y W 0 M u7 r 0 0 N N 10 r F F AREA OF WORK NEW ACCESS HALL F NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. r 9 B EOL EOL c DD 2A 6 . TO FACP t uKWILA FIRE DEPARTMENT, Please call: 575-4407, and give this job No. O 7 �' I of and exact address for shut• 0,,,Nn or restoration approval. 1777"' TO JC PEN\ EY CACP TO FACP TO FACP 9 B 1'777/1 B TO FACP FIRE ALARM PLAN - UPPER LEVEL STOCKROOM SCALE: 1/8"=1'—o" AREA OF WORK I. B E ®Jc EOL S Y B NEW ACCESS HALL m 1.1 r -n r -n xc- III C1 B ig-zr r J O Without Comments As Noted In Red O Per The Attached Letter These' plans have been rev:-.- by The Tukwila Fire Prevention Bureau '`,:or cchfc;: Canoe'. .,i1.h current city i L: *l!t+ til (errcis and standards. F.c::c:tio t tc:. i � . which.,',,.:,, ,; , ;,... : violations o,at• do pted omissions �^.rhi � do r:: �.:. �.,., �...._.. �,�.u�torl� t�f adopted stantaaras and s:..:r...:s. ..I"r : responsibiifitypfor the adequacy of ily with tie designer. Addition.-°, ra, r;s+t'; c.:r ^';15 to these drawings atter this data +o I rr; t�;. ....'.'r,-nce and will require a resubmittal or ; -:<<i_.'..' I t:! ::,:'inksfor subsequentapproL Final accor.:rri .»ct to field test and inspection by The TuFrwiu reventjon Bureau. Date: -7 By: a 1:kt I I 16(< CO"‘ O(4641/44 G 1 rtvrt FIRE ALARM PLAN - LOWER LEVEL STOCKROOM SCALE: 1/8"=r-0" Gf G7. ra ra 0 4' S' EOL IE C C C ` UPPER LEVEL EOL C c c FACP EOL EOL EOL LOWER LEVEL TO 120 VAC UNSWITCHED k DEDICATED CIRCUIT t TO TELCO ROOM FIRE ALARM RISER DIAGRAM SCALE: NONE EQUIPMENT LEGEND DEVICE SYMBOL QUANTITY PART NUMBER DESCRIPTION BACKBOX 14 AWG, 2 CONDUCTOR 'FPLP' JACKETED CABLE 1 D7024 FIRE ALARM CONTROL PANEL INCLUDED nc 0 1 2WB SMOKE DETECTOR 4 SQUARE X 1-7/8" DEEP ®4c 3 PC HORN STROBE 4 SQUARE X 1-7/8" DEEP 3 SC STROBE 4 SQUARE X 1— 7/8" DEEP I:) 1 - - DUCT DETECTOR (*) PROVIDED BY OTHERS DD 1 -- TAMPER SWITCH (*) PROVIDED BY OTHERS TS 1 - - WATER—FLOW SWITCH (*) PROVIDED BY OTHERS WF (*) — PROVIDED AND INSTALLED BY OTHERS WIRE LEGEND TYPE DESCRIPTION A 18 AWG, 2 CONDUCTOR 'FPLP' JACKETED CABLE B 14 AWG, 2 CONDUCTOR 'FPLP' JACKETED CABLE C 18 AWG. 4 CONDUCTOR 'FPLP' JACKETED CABLE GENERAL NOTES: 1. ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. 2. WIRING METHOD IS TO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND BELOW SEVEN FEET - THEN IT IS TO BE IN CONDUIT. 3. ALL JUNCTION BOXES, COVERS, AND BACK BOXES ARE TO BE PAINTED RED. 4. ALL WALL MOUNT INDOOR HORNS, STROBES, HORN STROBES, AND SPEAKER STROBES ARE TO BE MOUNTED 80" ABOVE THE FLOOR OR 6" BELOW THE CEILING, WHICHEVER IS LOWER. 5. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING: A) 36" INCHES AWAY FROM ANY AIR HANDLING SYSTEM DIFFUSER B) NOT IN CLOSE PROXIMITY TO ANY FLUORESCENT LIGHT FIXTURES 6. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE OF FLAME AND HOT GASES. I6' SCALE: I/S" = 1'-0" FIRE COM NW LLC v///////////////////////// PO Box 3932 Seattle WA 98124-3932 206-234-5700 DATE: DRAWN: CHECKED: APPROVED BY: SCALE: NO. DATE 4/30/07 CEA JD JD 1/8"=I-0" REVISION BY PROJECT NAME: JC PENNEY STOCK ROOM 633 Southcenter Tukwila, WA 98188 SHEET TITLE: FIRE ALARM PLAN JOB NUMBER: 07-019 FA -1 of 1 PAID I1 - 2 2007 Tukwila Fire �SZB"3 tie Without Comments As Noteo in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire ^revention Bureau for conformance with current Cit/ standards, Acceptance is subject 1:0 ;';'frors and .nisSionF which do not authorizeviolations of adopted ::andards and ordinances. The iespot?sibiiity ror the . dequacy of design rests totally with me designer, ,dditions, d 21etions r,r revisions to diese drawings after. this date will void tn;s acceptance and will require a resubmittal of relrisecl drawings for suer-' ent approval. Final acceptance is subject.to tleld test and inspection by The Tukwila Fire Prevention Bureau. Date: %"f 3 TUKWILA rim, DEPAR17,04. , coil' 200-57574047 g » Fire Ire Permit N e':act address for shut - ,own or restorationapprawi, y Corrogated.stainless steel hose with stairiless steel bras • � •i' '• avapabie In 2' 3' .4',5' & 6' legnths , .• Muill-Port Bracket 1s' is%;• +,BSc ■ Irl.7"1"'"u'i—ExtmAn Flexheadr ommerciai Ceiling Unit -r-Bar gelling installation Model 112024,2036,048,060,2072 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING 0 0 Z U O Z 6 0 1 LO STEEL JOIST/TRUSS HANGER DETAIL NTS• tI i 1i�lllli �i_somasummonoommil N OMNI SCOPE -LEVEL 2 ENLARGED NEW WORK RCP PLAN. SCALE: 1/8" =;1=0" REFER TO A220 FOR GENERAL & SCOPE NOTES \IV NORiQ CCro• w R.:NafrsgraNtgatigt4Fire `'. Probargon�h`• PiROTaCT,QNoPRLUt UY TUMi 978091-00 Level John Afil NORTH Design per NFPA 13 - Ordinary Hazard Group 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions ova ®.nei -= Relocate Reliable Model G Standard Response 165° Pendents 1/2 x %2 — Add Reliable Model G Standard Response 165° Pendents %2 x %2 Total 3 FIRE: PROTECTION:. � • .; INCORPORATED :.. P.O. BOX 12113:.<. MILL CREEK, WASHINGTON 98082-0113 P.H. (425) 481-7669 nal acceptance is sub,ect to field test and Inspection by t"le Tukwila Fire Prevention Bureau. ,te:-I-t 5 By: SCALE: 1/8 =1'-0" T HANGER LEGEND A "U" HOOK B COACH SCREW ROD D BM. CLAMP W/ "STRAP E � F FLUSH SHELL G CEILING FLANGE �rri SIDE BEAM BRACKET K SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD ,�/� EXPANSION BOLT S �� T 1 // /. W XY 1 / Z 4' Ai ��i"�r�riri� F PLAIN END FIT FITTING SN GROOVED SHAPED NIPPLE TSN THREADED SHAPED NIPPLE II-!ir�ii �. or- -.--.- 2 - WAY EARTHQUAKE BRACE -...--..- rice%ire .. 4 - WAY EARTHQUAKE BRACE �ro�rr r SPRINKLER LEGEND ii r�rir�r�rir�crr _.. UPRIGHT PENDENT f rri rrii icor i�sil 0 O 1/2" 2 w�.:::,,-,.-,,:.>:0,�..•..--e-u:...za .� ,.;,,....,".<.,.,...=,t:-_....,,.-.».....:.�...,<.._.�.,_x: .�// -:,�„"-«,;.moi 3 /,///r,,,0 �l%� ❑ 0 r/ // 4 32 SPRAY o 1" 1 3 7 1 < a 1/2" ■ T IT 2 SIDEWALL ---- 1" <> 1" 1" Z DRY TYPE ® • 1" STATE CERTIFICATION f----`-.-,,;.,..".,>..-,.._,.�„.z-. 2 a 21 2 ` 0n.1nc. p1 O 165 o &I 5 Q .�„���, .Iriirrr/�����ir����, /////AWAVAP //// ����� 1/2" ® 1- 0 286 ' Q �i 1" © 1 /2" q . Q�°�� Csrtificele � �'o0 lea S C• 6'b Gig �� r eau t 111. C• deµ" �; .9�.APPROVAL ~ ::1iG1:n: CE 350 , r e P.////wr.I//��......///��ir�//�///�// r 0 500 " 1/2" ( 1/2" REQUIRED+ia""' CITY OF TUKWILArhrdD�:``` P SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE HEAD FINISH ESCUTCH FINISH TEMP QTY RELV48.E C S.R. REC. PENDENT 1h" K=5.6 CHROME CHROME 165' 28 ` �% /p�%�1 //�/� of 7/1" 5 1 ill 111. 1 I��/�� 10 I s 1 / /, ,.trAr.dirArAi TOTAL 28 QUALITY CONTROL BY CLINT CARR DATE 3/28/13 APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. AU. MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2010 EDITION. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2010 EDITION. 6. JOINING OF PIPE AND FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2010 EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. AU. WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY OTHERS 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA 1. DESIGN PER NFPA 13 (2010 EDITION). PIPE NOTES 1. ALL NEW THREADED PIPING TO BE SCH-40. 2. ALL NEW GROOVED PIPING TO BE SCH-10. REVISIONS NO DATE BY DESCRIPTION //44 .., /�/j//EX. OUTLET -1//I 1 CONTRACT WITH: BAYLEY CONSTRUCTION 8005 SE 28TH ST MERCER ISLAND, WA 98040 ROSS MCKENZIE PROJECT JOME PENNEY WESTFEILD T.I. 1249 SOUTHCENTER MALL TUKWILA, WA 98188 GREG COSIMI 425-345-9609 WWW.PATRIOTFIRE.COM ATR OT PATRIFPO99CF mattgOpotriotfire.com FIRE PROTECTION, INC. 2707 70TH AVENUE EAST TEL: (253) 926-2290 TACOMA, WA 98424 FAX: (253) 922-6150 DESIGNER MATT GREENE SHEET 11 �p DATE 3/28/13 I OF 1 JOB NO. 12-15662 00 1m _ ,,,_ / ' �% /%I/ % / //%//Jyreolf 'oo"""rAr"ArArm II 1111 i dill )) RE-' 1"/�//� 11 Ill / �/ /4_/_/_ . /////// /0 / ,,,;. t'/; .",It"III 1,,; 11/;/f//, /////iiiiiiiii///.iii//i,//i///i/. / FLEXHEAD DRO V P,///�j� ,/ZZA1 //. ►1/ AI K MOUNTING BRAC I mu( „ ma _/ , /r A - 414 4091r. 1•1 I ar i PER PLAN '1::::: Imp ini Orae, l IP A U 111 i li1 Vii) `/I� gm : oo ,�% - i�))� $ /// /////r/ / / / // / ////////�/// // / / / / //// \ (�(1,/ �/ %�/'r,�ii�fSPRINKLER \ CEILING TILE-�O//////�� HEAD ////////�/\ 111.:. -� 1il 1.1 1;1 1;1 I,i1 11l 1�1 1.1 li, 1�1 li, lil lit 1.1 - '' a�/1/Al,,rj ,e , . ✓�®- ;,((( '))) lk ))) / (�_ )) ,-.)))) a NEW Mr -� PERPLANIt �o / %%%%�� / ���%%%�%�%� / / // ir ���v0, I.,FLEXHEAD DROP V MOUNTING BRACKI '01 NI og II , A 00 040/00,0 �� � %// A AA li, lil lii 1:1 lil I:1 lil lit ,:1 101 1:1 II 101 lil 1:1 11 l:f 1:,• - �///�% /p/i / / pe / 0 �/ / %%/o� % II X IXII III���'�� , .4 �((� �))) (((( ))))C' ((ll )l o (1 ((( )'�))) ) I.AI(// , �/�//�//�//14..:.... \ ,_ . 1, ; .. _..:, CEILING TILE-� �•Jf_ SPRINKLER HEAD !�Re-��//%�0%%��� /�// / li1 li, I=_1 ,i1 1=_, li1 ,a 1i, ,il lif I=, li1 l:, li, ti1 lit 1i1// FLEXIBLE SPRINKLER DROP DETAILS �//�// ,4 e 00 �//� / t \ 1 ' \ \ \ �/� �/ SCALE NONE /!1//,� �//// ��� , %�1��'� ��/� lit \ SII t, / \ } l if% r � t Arte �� 1/ %! Ii III 0 Id �J POST -TENSIONED SLAB 11---- Ili __..1 -mini hi.. hi.. II III.......... Ir/- II 1.1 1.1 1.1 - ji Ls ,�,■1 iii Lf til Ir...11.il til - lil• - 1.1 1.1 ` 1.1 - lil ` 1.1 lil ` 1.11.1 - - 1.11.1 74 A., 3 ATR CONCRETE ilillilIl' \ y1IIIIIIIIIIII-IIIIIIIiIIIII<IIIIiI' il IIIIItIIIIItiIIIIIII-IIII1r4 ANLFIG69 8" SIMPSON IA37S T1_UPTO4»PE ler re ','( , ii - �!�`' �' .ii? li, ,i, lil i, III �/// 1;1 iri ,i1 .:: - 1:1 1:, 1E11 1;1 1:1 lil I:, 1;1 li, li/ 1i1 TYP. HANGER DETAIL i/ A F . k 1 \ o `� �� //% Fit / SCALE: NONE 1-, - - 1, 1 1 1. . . I � - r\I_. . . 1 1 l-1 7.‘,.\ :24���\���'., „ �� \ ;'�.. / �/ vs,: NiMi 11111 IMO i 0// � :• ::. i:,,'•St a'? `, A 1.1 ,.1 I.I IN 1.1 1.1 I., \I .\ \ ,`,. , 1.1 1.1 IN 1.1 1.1 1.1 .'\\�\' ;\ ... re Or I lim 1 r s• III t 1 J AO i.„,:, L, ,___ _ im lixor or ,,t �'/ ill,� - 1 1 lil ,i, 1i1 1i, 1,., ti, _� FIRST FLOOR ESCALATOR WELL [ I lit 11li, li1 li, 0/�/ �� ' ;; A01 ll s II/ A !IlIIItIiIIII!iIIIIIIIIIIIiIiUIiIIIIIIIIiiiiIlIIIIIIII /A A.• 11 .. ■■ 1111 r II pr Y i irl 1.1 - 1.1 - 1 1.1 il I.!' 1.1 - 1.1II 1.1 1.1 - 1.1 I.1 1.1 1.1 -.- 1.f ,.1 1.1 1.1 1.1 1.1 - - 1.1 - 1., 1.1 - li III 1.1\ // ,Ago� 4.40: ,, \ �I III I \ � I,, 10/ /IiA ��\ � \ w, III ISI ,v .. . - '�'. '' - - __ III _II_lIIIUMIIlIIiiiiiai1iiIIIIilIIIIIiIIIIIII 11��: I I I.P10 te. r :t , ', :,,.,,,, 'Y,r: 111 161 1 1il ,i, 1i, li1 1i1 cit til tii lil li, of Vii, li, I VICINITY MAP erN 4 ..W AA 11 IiolhhilIti!lIIiIIIIlii;iiilIIIIII II ll!iiiiilIIIIIII!lIIIIIII"I l I l' £��/ ii, ri Ill----- iIlIWJ44 Ix lis ---- Ii1 ,i, ,i, -W 1i1 ,i, •i, ,it lil ,i1 ,i, til til ,i, til lit -III4 1i1 ,if ,il 44 10°1 1g 11111\ �, (,) )); I -Il \ Ill / NG FIRE SPRINKLER PIPING. FIRE SPRINKLER PIPING. RINKLER TO REMAIN. RINKLER TO BE RELOCATED. /w= 1i1 lis 1.1 1i1 Iii 1.1 111 111 111 111 lit 1.1 ,if 1i1 lit ,i1 I 1.1 lit lit 1i1 1i1 lit 1i1 (1- -1.1 0fry' \ \ / y \ i' / / % i A / lil / t � L1 1.I til 1.1 1., 1.1 1.1 L1 II lil 1.1 lilhill/ lit Lf II 1./ 1.1 1., 1.1 1.1 1.1 Lf 111 1.1 1.1 _i, / I X W - ll e N\\\\\\Na\\\\` NERAL NOT 1 1 , ,,, \ \ ((6, )) N 1 y (( I „, „„ « „, 1 , c(c »)) /,\'\ 1 ; \/ „„ ))) \ 1 I A, DENO DENO DENOTES EXI DENOTES EXI w/' i�l. 11.1'- 1.1 'll� ( li, 'ILlii' lit 11 oc ,i, 11 li, Jl-�,L to 1.1 ,iii 'is lit 1:1 lil IN ail 1.1 1.1 lil Iql 1.1 1.1 til lit ail L / I / 1 IlIllllIIIIllllllllllflhuIllllllllIlIlIlI L. 1 .t0 Pr 4.1ir • _4 F.' ili, \ii. 1 IN - lil ,/ lil 1.1 til IN . lil _ ; ti, \IO, lit \, Lt / 1i1 . . \ / 1.1 \ i A 1�1 ti1 / lil \ 1! / /II<IlilPi i>,) t!I., I Pi�y�(<<•_ gil I:1 1.1 1., I, .......• ...... ........... ..... ... ..... IMI II iiii ckI or roe' ��i�� / yr "il • J/ I 1i�,' 1:, li, 1111111 1:, ,i,III 111 _ 11, 1:, lit ,if Iil li, _ 111 ill ,il li1 ri lil lit JAW& A AO A 407 • I v \, A , /\ (« ») (((( /\/\ v(,,,) ))) ui"� ct I II 111 HLi 111111111 /_ 1" PLUG JLO �' J11' I_l JL I.0 . EV IJP �x-1s ry .O _ A. . l� 'w I E D:.....�,.� r f+..y,. ', TUKWILA .. .. 'e-.a,,.,-.;.-c-.s��.'as,_nerr. km.; a-:ax_-r...�-. - -m.,ab�:-,«,.: :».s. _�, �...n.;o.--:,�� .sem.- s /° - 1.1 - 1.1 1.1 lil - 1.1 HI Lf 111 - lI!lIlIIlIllIIIXI IIXJJIR 1..L- ■ Without Common ,a { ., �E give this Fire Permit No. �; 1" PLUG 1 Ix�. • /,/� O N Notedh I Per The ,;Oach�:.i Letter / �. and exact address Iil'uY1L down or roration approval. II �• /'` !1.1'.. iii il','':':._ 1.1 •'.I;, til "1�1' i; 10, � Z ,, FireA /,. xTh The Tu..v�Ila a been r evie/gad L v e TheseAPAYAPAr i_rn _ ,. a _ _ y m : _ ___� �� � _v 1rrrve � y , _��. L,.., Bureau forconformance with current C ty ^vention "ndards, Acc.r,,I-,F.r, = i,: 1!hie� to errors and �, �s adopted ,;;scions' whicc l c,, . ,_ ,,,,h j, I.._. solation. of -'ndards and rd r+arl':,=• The resporlsibi!ity tor the -ouac,,/ of de:::c,n r::. -.E KO al:v koi th the designer, oirions, deletv.,, EL r',r• ; `.gisions to these drawings after . r cia:7' will vase{ trvs :�•::eptance and will require a .s;ihmirt;, of. revisedcra8.-Jinc;s'orsubsequent approval. FIRE SPRINKLER PLAN -BASEMENT i' r / / / // i 4r / / I, / J ll 11 o o o 1 nal acceptance is sub,ect to field test and Inspection by t"le Tukwila Fire Prevention Bureau. ,te:-I-t 5 By: SCALE: 1/8 =1'-0" T MAR__ 2013 rifaggte HANGER LEGEND A "U" HOOK B COACH SCREW ROD D BM. CLAMP W/ "STRAP E EYELET F FLUSH SHELL G CEILING FLANGE H SIDE BEAM BRACKET K SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T U W XY Z FITTING LEGEND P PIPE -O -LET F PLAIN END FIT FITTING SN GROOVED SHAPED NIPPLE TSN THREADED SHAPED NIPPLE ADN ADJUSTABLE DROP NIPPLE or- -.--.- 2 - WAY EARTHQUAKE BRACE -...--..- 4 - WAY EARTHQUAKE BRACE (1 STRUCTURE TO CENTER j�� UNE OF PIPE ININCHES SPRINKLER LEGEND SPKR THRDS SPRINKLER ORIFICE SIZES AND TYPE UPRIGHT PENDENT TEE SIZE 1 5 3 7 1 0 O 1/2" 2 16 8 16 2 SPRAY O 1" 3 17 ❑ 0 3/4" 4 32 SPRAY o 1" 1 3 7 1 < a 1/2" T IT 2 SIDEWALL 1" <> 1" 1" Z DRY TYPE ® • 1" STATE CERTIFICATION TEMP RATING 2 a 21 2 ` 0n.1nc. p1 O 165 o &I 5 Q -e- 212 " In ,5y iQ 1/2" ® 1- 0 286 ' Q �i 1" © 1 /2" q . Q�°�� Csrtificele � �'o0 lea S C• 6'b Gig �� r eau t 111. C• deµ" �; .9�.APPROVAL ~ ::1iG1:n: CE 350 , In d = 1. r 0 500 " 1/2" ( 1/2" REQUIRED+ia""' CITY OF TUKWILArhrdD�:``` SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE HEAD FINISH ESCUTCH FINISH TEMP QTY RELV48.E C S.R. REC. PENDENT 1h" K=5.6 CHROME CHROME 165' 28 TOTAL 28 QUALITY CONTROL BY CLINT CARR DATE 3/28/13 APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. AU. MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2010 EDITION. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2010 EDITION. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2010 EDITION 6. JOINING OF PIPE AND FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2010 EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. AU. WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY OTHERS 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA 1. DESIGN PER NFPA 13 (2010 EDITION). PIPE NOTES 1. ALL NEW THREADED PIPING TO BE SCH-40. 2. ALL NEW GROOVED PIPING TO BE SCH-10. REVISIONS NO DATE BY DESCRIPTION CONTRACT WITH: BAYLEY CONSTRUCTION 8005 SE 28TH ST MERCER ISLAND, WA 98040 ROSS MCKENZIE PROJECT JOME PENNEY WESTFEILD T.I. 1249 SOUTHCENTER MALL TUKWILA, WA 98188 GREG COSIMI 425-345-9609 WWW.PATRIOTFIRE.COM ATR OT PATRIFPO99CF mattgOpotriotfire.com FIRE PROTECTION, INC. 2707 70TH AVENUE EAST TEL: (253) 926-2290 TACOMA, WA 98424 FAX: (253) 922-6150 DESIGNER MATT GREENE SHEET �p DATE 3/28/13 I OF 1 JOB NO. 12-15662 MAR__ 2013 rifaggte SYMBOL LEGEND • 2 -WAY EARTHQUAKE BRACE 4 -WAY EARTHQUAKE BRACE MATCH UNE (ZONE 1) MAT LINE GL'OHE 4) yv x'^•, REVISIONS Area of Work. • fr- � SCOPE OF ; 'I rer IO Mill Adr ❑ "ply rs r! WORK srA>a ELEVATOR II I I ,%J■ r N. ..ami r al i mum �II�E• �V � � �A I , ! • MAW li -P� ,�� -_j!� i�!31li-=��'-" �� L��� CSI �''!► j ! I I ! ���' r sTAFi3 1! ' �',• i � + - A* 1 I ni g, � ire A . FrrTwoae milLncH! . � ' ISA/ �I/'"f/'�I �� � �'' �'` � �, �_-�_v:--,. �, I' I ' ��� � :G1 � - _- - - '-r� �r41.11".4 �� = � � 1►.11 •�indi � lini►� ��I/ • AIME rarAi lr .:: k i p '. Alli�" ► �, / ► 1 IG■/ate I:rall I� . .1®�'.Il� aiin.�r/>Y'.�IAIWAWIZZIldrillArigrr JAW 11 IMultim swan 1►I NTIMP IEWA ANN VAM!1115111 _I 11111 AEI AllifirAnitrardrar Afflarailm STAIRS !rPARIPAI������� ���� ''•���� t' P ti � '' ' r riems I��' I d I �- ■/ 1 [ t I STOCK ralPATIMINFAVAMPAVAINV 404110rArarAllrAir I -IIIMAD M ' AWEIr IAar AM WAVArdrAVAdrirargrAdrdrar Armardp,i A�.!�i������� �11/01111•11V I elf . ---- i i ® r I 'r I '!� i , I TIMI I/®N ' �INL! i IBJ i 'A AV� !'I NTOMP _lm� . • I ! .__•�!_ _'_' I r! =- �.AL �!_ SCOPE OF �EMBI��I':1� a�I '' .MeV���,;�.'!�'_ � I�' � �r ! OUT OFI/��/ i eirlrarirdif �' I' ® _ ���'� ,'_��/,� ! �r Vi!rlP�� .■/�/'WOR• ; / r/ %� /I!rirdrirArAWAVAIMPAPIONFAVOML4PrArw:ra . �' 111111 Ir' ' . _ _ ' _it . 1 ! ■.■■•._r ..gr __4r ; . ASIN �1 ./ IMPAARIMP/1►�M � Affillair :IN>i �, /!1 `1 • �. i i��� ' gAM'KI '/Orel I1 1'firr��;-,,' ,'I' in 1 % 11 A 1 NFAIM I ��l, � MMIII.OA� �W ' 1 ,i11 d®.�. 1® . � N 1 d ffi.�! 1 /1 ,1 1 N 11 % 1 /L1. 1MIM C 110 AI�� � ' �irW r� �AVAl �'' ININ !�I !` it ' r, I OUT OF I I / 'init 11 (-, ArArammir r� i//' S WORKCOPE F A,�,►1/ ��I�' WAS �IrMrdArdirirarrArarArawArgrAr��I r ��d pi r l l L�IM M E � MEN �i .�� � it ri .ire Arare.r A An OUT OF - SCOPE OF = WORK OUT OF SCOPE OF WORK - OUT OF SCOPE OF WORK OUT OF SCOPE OF WORK Area of Work SAVAPAIr I AMPrAPAPWAPITAINIPBEIWAgrAgrAdrara rArAgrar r A ANEW AV ANAMPAIMP" AgrAIWNIIIPArdr APrAPAIVAPEVAdrAIVAPAVAIP'AVAPIPA/PITVMNMP'Alnit �o / l I ®lil iV !1� AINVA ��'ll ATS �. II ,1 1_ EI !� ®`I mal Krill r 11r' .Anifd 1�g.11drP 1 ridr rAPjlu ► rdrl • 1 k4 LJ�'' � �' �I_J��� r.l iia.+ iY4•<%i' .w mid" Gat :aw - ! � �1�.w � .. �.ew r. �.. dry;,, i�{�. i� - I ! n ..'" ^�^z'2: IiiirAWILTWAMITA AilivAmmaTierairieri 'J I' r AV��A MM �AV W ! ai L.� L�Ir,� 1- !1ArAtir A� •.�1IN.� I'IFY'd,IaI�t.�.i ' ' I ' I I'' I I �I 'I� ' M /® L! AFAMPJff � '4' �/ /-�a�/I�/L'_�s1-/�i�, >' I .' ,1 '' ,I ��A IREM B �� ���L'�/ r [i� 1 �' I�r I ��� 1 �.� 1®�.�1�.��I�� � 1 i � . � � . � I�� ���./; � �`_I � _ 11 � � .1 � �� � e I � '"; � �'� �`a �l OUT OF 4#13.:W.?'PEW/� r'u�, ,.,., � � � O r � SCOPE OF +�A �� I I . V A .W� � C' 1 r`a,.. !,• C i WORK i! O O F - 4 f rArA A� ' ���� ����., rI �I®eel�ri® ®ri /.�In!-"1rl r ;► �j,.�r-�.IOW APO 1011/1,11PAMMLI �l ASP' �' � � r �//// ;rl I� it '� r 1!�� �h�AV.�i o .� �/; A.N�11/111M 1) ��pa� _�� . ;1�� 1 EHMIN �P.E1i1 Alli glifi l��I� / I OUT OF Ally r� �Aral I. �l. - !I - 1► !7 � ��� I� �AVA� '° A'/V/ Ai!'ri 'RVAI SCOPE OF ��'!��� '��� ���� ,� I i r iI / WORK • ! ��• ' ��I� FAVA • '• r.N/IW'iN�/V./�/w Ardr � 11 • I 'A �rodrea �,�'' ' � I ' gar 1 Ml _:!:� 1 �� I //�. / ®� ,i /� 1 �i�.�� .�.® APINTOMPIAVAMPAVAIMINIF APIVATAIWAIVAUFAIr , ,, ! • ; A!i_.®1'�N� �� � �I//���.�� l�� 1 //.��iir.,>d�'. -AMP' �� �► r IV Adion r� I�� �1l%� .�/.�.� • ! ; a ./� SCOPE of . AI I .� . i �I .�� .r 4 IA �' AMIN rAVAIVAPPAr AITAWAWAYMPIALINI 10111WAVAIWANT Ar W :. " ; I AV111I riparamparAmpro n,®�I--�� w' /_ � , �WORKi'!�' r' � ,'''��, � �I �� I��'I',!' � I'' //� r% I i �r : '.Jn grgs�� ./1mpLI ' I,Li d L_orAmAr �I n i�`1mieiidtirA '. f AiammA�._ il-JBa�I__�, i i I 1 11Pr Airampr „gimpy AriplimilimAp ii ►� /ii II!/ ArAdr APINIMIVArr Ir� i'�.I , ' L'I�'' ► I ! ��i !OUT OFAV PAA ''.fd ' ' 'J� I ArAAR111 "// � I ��►I _� /_�'r�I�.�.t�i_���_ /IV ! !/ � I �/ � SCOPE OF + � / �/ / - I 1111 �I,� �' ® I I A .1�1� ■�..IRW li . � : i/ 1�� � �I I ANI , ,� N! • ./ I��.���i�' .� /�� 1 ; ' � reri � Iiferrollipir'� woRK r,-. �f� rlt•Is�'�I7JAa ,j ,.! I'l !direr/NN1�`' ���►� - I�! �. - �� ��'''; ; : : Imo_ �." .�' ..Iasi �h A r ; �': � ralffidr Afar '' ,�� r ►'•�; �Ir, _ ������_ � ��'a` _#; A /� _;� fir_ _ ��� r/ Irl'! ���1 /►.� /�.� 1_ �./�!�� I .�!1 � li_ � ,.� 1 �.�.�.� �i� � _ r1!��,�I>.;��'.�.or '-�'�!� i��� i i , • - �/! -- � I : �.�'� ��" �I a' hN.���1►I. APAI .!/ 1 INN II.!Ii! /•• !�,.���.����� � � � II' �'��� � � ,��` !III !a ���� � : . , AREMPIO" AinfrardingirAIM.AMWAY ArArardir ANDEF AFTWAPAPIOrer WAPAPAINE f , �l .� ������� � ���.�/i� . �/��.�!'� '>r��i/1� 1iipijiiijiiii.ui_ipr4101 A.� �� r11 �" it 1 1 1 i'1 /1 I !1 1� • ' Amy / 1 now /' OUT OF i :! ? ! 1 . , ` ! I ! I ! .� :�/ i ' ! / ���� ����: ' - SCOPE OF P � ��� � �Pp I I alFr-IVAIVAIriIFIRM WORK / r1/� ; ! ,•;li1ar1rat11_Ei � 1n 1 i •����i ,•I y �. • Imo, `-I� / n I 1 OUT OF I� FI AES! PIA /1 ��!i ��1WAEL1►' .PIN1�.AIMLI BTDCK • > 1,�'�.®� 1 , �N.�.�- ' I , I I ' B rill ter' scoPE OF � _ F.` "' .��� (�� � _ � � � • / � � / 1 �I - I � , � �/ N-•�/�-'._ a.:a � �' _WORK—�11 ! tr Kiri f' iladlE IEVA INFAM ' � `� OUT OF ���� �� .I • �''��'� WAY.'" 'r'', '® ' I ELEVATORSCOPE OF / I 'Ad `I ATAMMI ESTAIIP.OI®_� AI� �DS;; I - WM Iai i .______AI_Y- - — - -- — — ANFT AP7:4?"—i__„.2fP6FiNGEmmcALPm,..EL. i OUT OF SCOPE OF WORK FREIG ELEVATOR /�/ ac 0.15 FIRE SPRINKLER PLAN MIDDLE LEVEL 1/16" = 1-0" Sprinkler Legend NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 12 5.6 Pendent Chrome 155°F Pee - HYDRAULIC REFERENCE POINT HANGER SYMBOL BRANCHLINE RESTRAINT 23 Total = 35 5.6 Pendent Chrome 155°F APPROVAL: City of Tukwila CONT. NO.: KS0355 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 07/09/08 \Area of Work i U•. MATCH UNE ¢ONE 2) MATCH UNE (ZONE 3) NOTICE Weld stamps must be inspected before pipe is hung. Do not paint pipins prior to hydrostatic test approval. x CE TE Without Cbmments As Noted In Red Per The Attached Letter t nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subiact to errors and omissions which do not authorize violations of adopted stanaaras and oramances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this.acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Sure Date: O o Bye P700 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY -OFFICES LOCATED ASS WEROUE/AUSTIN?DALLAS/DECATUR/DENVER /DULUD1/HOUSTON /KANSAS CITY LAS VEGAS/MINNEAPOLIS /PHOENIX /PORTLN10 / RAPID CIN /ST. PAUL/SALT LAKE COY/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 ti i TUKWILA FIRE DEPARTM .NL Please call: 575-440Z and give this job No.tg--- `J 7 arld exact address for shut. oo, A/n or restoration approvalj AI D JUL -9 200810P Tukwila Fire arm q r02y9 JCPenney 1-280 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER PLAN MIDDLE LEVEL 7.7 a -0 Gr 0 It .7) N Ll i L' 'Ql iliri•� AIS !MP! Nr r r '� ; At AffrAmmir I ESPIIIV T Mt% eAA'i Jr OUT OF SCOPE OF WORK FREIG ELEVATOR /�/ ac 0.15 FIRE SPRINKLER PLAN MIDDLE LEVEL 1/16" = 1-0" Sprinkler Legend NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 12 5.6 Pendent Chrome 155°F Pee - HYDRAULIC REFERENCE POINT HANGER SYMBOL BRANCHLINE RESTRAINT 23 Total = 35 5.6 Pendent Chrome 155°F APPROVAL: City of Tukwila CONT. NO.: KS0355 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 07/09/08 \Area of Work i U•. MATCH UNE ¢ONE 2) MATCH UNE (ZONE 3) NOTICE Weld stamps must be inspected before pipe is hung. Do not paint pipins prior to hydrostatic test approval. x CE TE Without Cbmments As Noted In Red Per The Attached Letter t nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subiact to errors and omissions which do not authorize violations of adopted stanaaras and oramances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this.acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Sure Date: O o Bye P700 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY -OFFICES LOCATED ASS WEROUE/AUSTIN?DALLAS/DECATUR/DENVER /DULUD1/HOUSTON /KANSAS CITY LAS VEGAS/MINNEAPOLIS /PHOENIX /PORTLN10 / RAPID CIN /ST. PAUL/SALT LAKE COY/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 ti i TUKWILA FIRE DEPARTM .NL Please call: 575-440Z and give this job No.tg--- `J 7 arld exact address for shut. oo, A/n or restoration approvalj AI D JUL -9 200810P Tukwila Fire arm q r02y9 JCPenney 1-280 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER PLAN MIDDLE LEVEL 7.7 a -0 Gr 0 It .7) N Al AM' AIM' AIMED' I ARV wzgrAriir Amor OUT OF SCOPE OF WORK FREIG ELEVATOR /�/ ac 0.15 FIRE SPRINKLER PLAN MIDDLE LEVEL 1/16" = 1-0" Sprinkler Legend NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 12 5.6 Pendent Chrome 155°F Pee - HYDRAULIC REFERENCE POINT HANGER SYMBOL BRANCHLINE RESTRAINT 23 Total = 35 5.6 Pendent Chrome 155°F APPROVAL: City of Tukwila CONT. NO.: KS0355 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 07/09/08 \Area of Work i U•. MATCH UNE ¢ONE 2) MATCH UNE (ZONE 3) NOTICE Weld stamps must be inspected before pipe is hung. Do not paint pipins prior to hydrostatic test approval. x CE TE Without Cbmments As Noted In Red Per The Attached Letter t nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subiact to errors and omissions which do not authorize violations of adopted stanaaras and oramances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this.acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Sure Date: O o Bye P700 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY -OFFICES LOCATED ASS WEROUE/AUSTIN?DALLAS/DECATUR/DENVER /DULUD1/HOUSTON /KANSAS CITY LAS VEGAS/MINNEAPOLIS /PHOENIX /PORTLN10 / RAPID CIN /ST. PAUL/SALT LAKE COY/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 ti i TUKWILA FIRE DEPARTM .NL Please call: 575-440Z and give this job No.tg--- `J 7 arld exact address for shut. oo, A/n or restoration approvalj AI D JUL -9 200810P Tukwila Fire arm q r02y9 JCPenney 1-280 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER PLAN MIDDLE LEVEL 7.7 a -0 Gr 0 It .7) N .." Area of Work _ Existin Branch Line - w z 0 111 z Lii z 0 9-0 A.F.F Ceiling STAIRS 7-6 A.F.F Walls OUT OF SCOPE OF STAIRS STAIRS , A Aummor 11/2 11111111111141711111111:1 M/P.RW I • //X 1101111 1111111111111Aipr LIR 111/11111111TIPIP111/111/11P11-1111111111161 FM" Arr IF 1, P STAIRS STAIRS STOCK IP my. 4VVH Arir Air • Pr Arr 5 ArrAirter Air Amin Ar Air 1 141r r All AAVrpJ- - maw AIIIIMINIVAIDVAIIIIIIIMITTAIWAMIVAINV Sill MI Aff Ar lakprim A irr 411 OUT OF SCOPE OF WORK ' dir A' i.,-<,,--)-:'---.,-,---:.;41, AArArirAir ArvirAPPAPir AgrAr MATCH LINE (ZONE 1) Ir 11.1... Lir A 1r Adr :; Alltrairff .,.(:;=.7_-=`,..1:T=========',7=-2a.L-,,,,,,, .., ,,•.,...-,,,,,,,z,,,„w.m :,,,m,?,,,- ,,,,..,:-.,--4,.. 1 1 I ! I i 'MATCH LINE (ZONE 4) i . Aril ' Arr' . Arr V ry Al1 AlT AdilMETIIPWAPIIIV t , 1 i , fir i .....: :.„. 'AV ,•...:.r. , ! 4:_-_""i 1,. .0.1 • i . Air AIV AV Air WAV, ' ti)'• .E>i AM ArAwr Ir u1A Air Ar AVAPPAr AV AVArdir WAIN INAMPPArdliffr APAIMPArr AV All AWAVAV Alr.--1 AV .. ,. Arrl ARV SYMBOL LEGEND AMIRWMIT'iMEMS.= OUT OF SCOPE OF WORK :54MITOIsiE REVISIONS ,• OUT OF SCOPE OF WORK I/ /•i FIRE SPRINKLER SYSTEM 1 Ird WA SCOPE OF WORK EU • Adrer: .-L-_-_-ermir-A.Amor,firAmordrANT•rAmmi. 42111VAiirMirligr ar WEI LW /111111rammair . • 2ND FLOOR 1 /8" = 1 '-0" 4 441! ak-Thil 1-4.V....2" • Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE 12 5.6 Pendent Chrome 155°F tFR rv_rni - Rat - 1 HYDRAULIC REFERENCE POINT — - • HANGER SYMBOL 23 5.6 Pendent Chrome 155°F Ec BRANCHLINE RESTRAINT Total = 35 APPROVAL: City of Tukwila CONT. NO.: KS0355 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE 07/09/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. WESTESF136OF WESTERN STATES FIRE PROTECTION COLtPANY- OFFICES LOCATED ALBUQUERQUE /AUSTIN /DALLAS / DECATUR /DENVER / DULUTH 1 HOUSTON /KANSAS CITY LAS VEGAS / MINNEAPOLIS / PHCIENUU PORTLAND /RAPID CITY/ ST. PAUL/SALT LAKE CM/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 JCPenney 1200 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM 00 w z 0 Adam Kantner a 0) 0 SHEET Bayley Construction FP -2 OF '8 CONTRACTOR. I 1 , , I : ; • i , , , , : , 1 : . . . , . , . , 1 , , . , , 1 10 , REVISIONS ,• OUT OF SCOPE OF WORK I/ /•i FIRE SPRINKLER SYSTEM 1 Ird WA SCOPE OF WORK EU • Adrer: .-L-_-_-ermir-A.Amor,firAmordrANT•rAmmi. 42111VAiirMirligr ar WEI LW /111111rammair . • 2ND FLOOR 1 /8" = 1 '-0" 4 441! ak-Thil 1-4.V....2" • Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE 12 5.6 Pendent Chrome 155°F tFR rv_rni - Rat - 1 HYDRAULIC REFERENCE POINT — - • HANGER SYMBOL 23 5.6 Pendent Chrome 155°F Ec BRANCHLINE RESTRAINT Total = 35 APPROVAL: City of Tukwila CONT. NO.: KS0355 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE 07/09/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. WESTESF136OF WESTERN STATES FIRE PROTECTION COLtPANY- OFFICES LOCATED ALBUQUERQUE /AUSTIN /DALLAS / DECATUR /DENVER / DULUTH 1 HOUSTON /KANSAS CITY LAS VEGAS / MINNEAPOLIS / PHCIENUU PORTLAND /RAPID CITY/ ST. PAUL/SALT LAKE CM/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 JCPenney 1200 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM 00 w z 0 Adam Kantner a 0) 0 SHEET Bayley Construction FP -2 OF '8 CONTRACTOR. �.a - ,41 DJ LU o < O Z z J n =1 f2 (F2 ....... 1 _ _..o, a �i 1I i I i „...,, I , mi it I ■u I , u i j I I i FITTING ROOM 10'-0' drAIPArAr;I fir®J . AAINEOi ArAIVIMIWAV A STAIRS STAIRS OUT OF SCOPE OF WORK OUT OF SCOPE OF WORK Area of Work 11111511W. OUT OF SCOPE OF WORK OUT OF SCOPE OF WORK Existing Branch Line •x .:1..o-..ins.Ss'ins;.'n„`�.1�•%',eR.F.n...:}« .wn,`.<£.u.a.o;,mun..m 'o:exx A v 1 ,x.:cxr .'tiaxra: i G I 1 44,4' .;YVi1 MATCH LINE (ZONE 2) JakezwzmmanizamaaaMATCH LINE (ZONE 3)A FIRE SPRINKLER SYSTEM SYMBOL LEGEND REVISIONS 1 /8” = 11-0” Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE 12 5.6 Pendent 111 Chrome 155°F HYDRAULIC REFERENCE POINT 23 5.6 Pendent Chrome 155°F 'F. IFR cacti, - Rex, Total = 35 ink APPROVAL: City of Tukwila CONT. NO.: KS0355 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE 07/09/08 Western States Fire Protection Company 7102 180th AVE NE, S 1 E A-105 - REDMOND, WA - 98052 Lic. # WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE /AUSTIN /DALULS/ DECATUR / DENVER /DUWTH/HOUSTON /KANSAS CITY LAS VEGAS/IAMEAPOLIS (PHOENIX/PORTLAND/RAPID CITY/ ST. PAIR ISALT LAKE CRY/SEATTLE Phone: 425.881-0100 Fax 425-881-3030 oiws JCPenney 1200 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM 0 C. ) FP -3 L/ SYMBOL LEGEND REVISIONS in I I • I a • 1/8" = 1 '-0" Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE 12 5.6 Pendent Chrome 155°F HYDRAULIC REFERENCE POINT 23 5.6 Pendent y2 Chrome 155°F Total = 35 tf- (-qec E.-A.‘cr; fl5 APPROVAL: City of Tukwila CONT. NO.: KS0355 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE 07/09/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. it: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALEUOUEROUE /AUSTIN / DALLAS / DOME / DENVER / DULUTH/ HCUSTON JIMSAS CITY LAS VEGAS AIIIIYEAPOLIS /PHOENIX /PORTLAND/ RAPID Clrf ST. PAUL /SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 MATCH LINE (ZONE 2) MATCH LINE (ZONE 3) JCPenney 1200 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM - . ,, ; !-- (..) LJ _ • I • , -. • • 1 . 1 . , .. , ' to -I ! , . I RI I I A r ANIL r 1 , , LU , , , , 10 , * I , , . . , . , . , 1* I , .11 . 1 . I ,,, , , Ar . , T ,AI I • 1 * 1 * , . r -Pr ! , . 1 1 ! ,,, ! r i ! Al I I I , Irr r , I I 1111IL 1111 4 /MI , '- ' 1 i Aar , I 1 , I , Ail . Al , ! API A i • Ai I, 1 , i i : , , imam :.-..,:„•-:,:.„-::,,z,,,,,,,:,,,,,,,,,,,,,,,mamawm., - aitzmwmatammenquaiwm:ma.41=40-1,:. : mr. '', :MAW MMOWARA4MMkt-- - • 'MEM= Me.' v'' '4 7 • ‘,5Mes • '^ ' M. VM4M40,14Z.MrM''M • & - Ms'L --,• z' -4,..; 4 k,' iY - . '''''7Ik*aalWAIMI .' 1 i "' . M.SlisI. '' .. WIWAMM.M.r,'44=MTMOMM ' 'r.-4. !Wi•rt ' • ',-= ' •%5.:d ' • `naa.' .,..30L.M.11WAM'w • ' i.Ax - s"' --nuig;E:z* Igi--- - - -• • :, • - - • -• • .,-$. - .- - „ • : ,; 7 ,t.,kniactr , 1„,,..; 1.1.1"„,,,,,, . rm._ t.4 , ,,, „. / . itt 41> • • * • I I 1 ! i 1 i 1 1 / . , I . . ; I : . Pr u-- IA F - - --- , riv... , , -Pr -4W - IH , . . . 1 , . , Na. rii ___ _ ___ ' LI _ Ll LI Ell i ® , . i , , . . , i . A AM • Awry Arr :., • • A • + , , r AkiArrLi 1r /III I . III PPPIII . . ' 1 ' SAFE I 1 1 • 41111111112VAIMIII. /12111111MINAINFAMEASIrrAillprrAILAFAII2111.1111IArAmm Anumemr, VW V , Ariii 1 i . Il Air. . Allir ! 1r AlPi Ara- 1: 1 : ' Altir Bo 1 , . , • I • . i . _ .111WrrAllilirur 1 •-,1 „,,, „.. .:.-:. , r-, I rro i , ' DOVYN TO BASEMENTJ . ni , , , Heix•ir , , ! , • i p P4M UP .I.0 2.. J.,145.0011 I ! ' yl . , ' -: I '1-1- 7AV' AV .•__• I I .ANYANIMMIIIIIAlsr , ; iii Aar Aiffiri ...z.;:rt_r , -.. • :;4::. • •:'l .:. ....4.:, , I ! • & • ' - - • - AMIEINIVAIMIIIIV • SCOPE OF .Ainv _ •--- :-',:.-",.:.,.1 :./.1.. I / t %, • I , • . I •II1i. I . 1 APlir ! t:-...-- . . ....„-:„.--..- , ; . • Ar , ii67- , ... . rer u4.'..'6.s.,',.4 rj •. . : . I , , , Addr i ! , iI ; ; • I * I I ' i • 1 - I . Ad , — iftp-r- A : 1 , ; i . • I 6rawArAdoweasgrAilirrAINFAIIIII-Airliwom . Al di Ai Aleri . I rirr ALAVA/Pr 11111rAVAIral ii Irr 1 ...,____________, • _ .in 4EI ! . . Cr. Lir Er ! In LE NI * • lArr :' : , r : . ' - 1 17 . •. i A Prld Ir Ayr i W AI . . rirrAir ........r.Ai , , , . . , I . ; 1111 r , . k * • + • • ; * : • - , ArillialiWil: ! , I .; 61101 : I r ! AIM 1 , ,,,,•3• : r 1 1 I - . I i • • : ; • ! • * I . 1 • . , , , . , i Al I ! Ell ! 0 - i ..: . Agnir Aro; . , , Arr Ally A r A Jr:Arm' Alr', ____ • 1 All . : . , i • !II , 1 , --:..F.- -:' . , I I 1 : ; .. -i -• -. I .1111P1 lair ...._.. AdIr . . ' i ; i , • _.. ..._..., I . .._.• : : , , i 1 i : 1 . .:::-!-::7;:• : ; : :.: , - ! . 41 f.., ,, i - - s-', -, ! I . -...:. • -., • .. • . ;.;‘,•:.:24•-, . , . , . , . .. .. . • .. .1-t-,-.•/. i . ArerA , . T ! .. . I . ,,3; i Ail i . . _ . • . A 1 .. , , . , WORK, I 4 , . Aill°P:HIA - . . . ' I ir A - Er . ' :, irrAirie AI Ai . AA . • 'IN . I I Araill7 . I ' i I • • . ' i 1 ArrAir Airi I t , 1 ! :Aar Arr ! , . 1 i I. I ! , i 1 ...... i I ! . : • . P' •Arar , , i . i ; • , . I x, 1 • i II ':'i * Ai. • ., : . , I I • , • • , • . . . . • • I ; * AI • ! , i ' I • 1 ; ; * ! , 1 ii i , 0110 ,-- ... • Apr r ,./1 SCOPE OF A , : lAr, , • . Al AllA Am 1 . r , . ! A'Arriir1011 Aapi . , ; . , ; , , ! 1 1,ii , N , •:;-:_i -.- -• , ../.1.4- •:::'' 1 i i .,......., ..•,....._••... . • . i , , 1 ; ._.. , .---i-•.;•; ; , , 1 ,_. . .........., , 1 ----- • • ; ........._ , I • , , ....:::.,•,,.1 A — 6 f0 17 'Air1 \ . . , i • 4IV i ; `.:::-Lr.-.:.7/ A i I ' \'..:3:.' ," ....--:- . i . 41- APPlir :411WAAPPlir ••___.- 1 , ..,.....J.,,,,! , :.7,=-:',i'':•? 1 Farr m -2,- • llama W. ''- maTIal• max“.• mamma ......!,. r -=F3 . ---' I .• • 41, - , ! Att. FrTHI, LA I. .' i . • . * AI 1 .4 , i rialigimig I , r '---I 11111111111WAIIIWirerWAIIII2porr AummorAsimiwimiummiimisr + , -""Alltra i le-'- , I Ilr.._.„ • . 1 .1 : • Iry PA Fr ire 10 WAG! 11111W I i IPM AlliiiV AI AirAdr I . VOMENt i : 1 PADS AI 4411111r Idli - „Mill _A I ; 1 i . l':' 1 ,, l 1 .• .- ; , t; i I ; I • I 1 Air 1 I i. • ,. . i - ..X . . 1 • . ; I . ; 4 r . ! 4r, . AdrArdlL, I I I frilly M-1 . • . • . • 1.- _ , . i4 I ,, _..... • ! I , Idir . . , . . . . . Pir . . AV, . 1 , . ....,..,.. . .,i! , !Air. , I I 1111" : , , n . . A . 4,3, , . . . t 4., .• • ,411 • A i A ! .0 . . . , -- . ' ' • ' " ' " " " ' r ,--• ' PF , , , • • * ' , ! r 111 ppri 1 I Affr ii . i 1 ! 1.11111111111r , 1 . Mir ALF . Ai lir. :' r AA 111 . --- 4,11rA , • . __. .,.._... ,i,..,_:/,....:,.., i . ...,_ ..... .,„ . . . . • . , Air . 1 1 , ArdrAr ' dr 1 _, ...„ • _ .• • . ..,, ....• •, .... , • SCOPE OF ; .• .,, .:,., ;-•••1...,::: , •„,.. ,., . ...„.,_.,.,,_.- , 1 , . I • : A . ...._.:. ...... ! . . . . , , , . . . , . • i * , • 4, , . , (::iallrAir 1 , i , _ WORK . , , _ , . : . . I , . ,, , , , r. . , . A ii . . . . PArr • . , A ,. , IIIPP.„ , , , . ' , , i , 1 , I A . • . 1 , , , . . A . 4 , AIIPP . — Ad I . . • p A Air A I ... ___,L. , — II • , • ArArAr Ara! .E:1 lir . I , A i • i ; . .....70 IA 1 • i i r !RI I AM p • ,.> . , . , . ....... SERAINVIM • _ , r - ; r_... or lb , i .-::!-.-:://,'. mr: , . 1 ,., „,, r AP' i , tr. 1 , . i A APIPPPr 1 OUT OF :„:, A , .... . .... %...„.• _ . ..ALL . • • . ,, i i.,, ! ‘,,,..„.,_..:.:..,ar . • , . , ,Airr, dip 4 : I /STOCK ,, . ,. A 1i , ! ANEW ' AuurarwmrPvm-id AI SCOPE OF r ! , .A or I i . ..-, I I I Viiiig I I 1 WORK 111. .. . _ 1 INIMIAIMOI • ' • I 0 I I- I iii i. , ' i . , . ! . ; . . • 4 i 1 I I Ihr . I i r.i. i • 1 , .• --- IA IF i i . - : fl, , ! ! , AM i IA MI MI Pli iiii M IM , , . • • i , ,Al. . 1 ; "piwiriliw • : _ ;Aiitli _ mg MIN , r _ : [1- _ • :.-- [ l• IN-.] • I , 1 AP Ir. .........„ Existin Branch Line STAIR STAIRS . , , • 4 ' , Gent zE .. ELEVATOR . I . • . — . I , • . 2 -R WORK . . , EXISTING ELECTRICAL PANELS • Aci• . , . i i . . .• • • • . , 0 ... ._ _ _____ _ .. ______.______ ... . . ...... _ . __ ___ . .. . . ____ ___ _ __ ___ _ __ • - - - - - - -- - - - - .-- ---- ------ -- ____, _ 44 lr.1 I I Ir VA liN Elo --- -- •-• - -- --- ------ . . • - , .. . I 1 111 grA IN I= MN wl M -1-1•2 Ad . ui pal . Z ,:.4 Z • 0 kl 0 . .- nOtTnAN‘ `4.741S i . . / / /FRPIC".1-1Tl'4\] UJ 1.11 i 4, . . . • . • . . • FIRE SPRINKLER (7 \ i Area of Work , . . . . • . . . • . , SYSTEM 1 3 5 7 9 11 F 11131-152. -Wm -res -Es -Sr SYMBOL LEGEND REVISIONS in I I • I a • 1/8" = 1 '-0" Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE 12 5.6 Pendent Chrome 155°F HYDRAULIC REFERENCE POINT 23 5.6 Pendent y2 Chrome 155°F Total = 35 tf- (-qec E.-A.‘cr; fl5 APPROVAL: City of Tukwila CONT. NO.: KS0355 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE 07/09/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. it: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALEUOUEROUE /AUSTIN / DALLAS / DOME / DENVER / DULUTH/ HCUSTON JIMSAS CITY LAS VEGAS AIIIIYEAPOLIS /PHOENIX /PORTLAND/ RAPID Clrf ST. PAUL /SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 MATCH LINE (ZONE 2) MATCH LINE (ZONE 3) JCPenney 1200 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM U :U MATCH LINE (ZONE 1) ":a>.aA'x` ay; 3; : �,�'n .. N.i: A"ua.^�a�aiczsn�;�•=J.., MATCH LINE (ZONE 4) ril ! I ! I I I � i i I UV OUT OF SCOPE OFALM Air P WORK i ; ! I of Ar I i.`;.. ;,.; JIV i AMP" At i ! Aar 1 AFAV I AN/Pr c AlAar Al VOMI Ai • ©IBJ OUT OF SCOPE OF WORK OV1M FROM 2ND FLOOR r V W���/IAr,, I c'rfor Er Er la Mi ilA I i I 'i(i -i •i\YI 8 A ' MPFAV OUT OF SCOPE OF WORK OUT OF SCOPE OF WORK Air AllrAl ' 1 AAP:, „air AFAIIWAIP ArArrAffdr - Air -Fir �t� /��l�/�TOWAF1 .tial f APPArArr WAIMITar Ardli AMP"I i, i I! Ai! -I j 4IVAIV i V Al'?I ir i:< ! I Allr STOCK OUT OF SCOPE OF WORK Z Z O ' LuO z f. z J £'J hx. 2 .-41 U r ' U 2 U_ 0 U) r- 0 0 Li) cts isYl. SYMBOL LEGEND 2 -WAY EARTHQUAKE BRACE 4 -WAY EARTHQUAKE BRACE HYDRAULIC REFERENCE POINT HANGER SYMBOL BRANCHLINE RESTRAINT REVISIONS DESCRIPTION / FIRE SPRINKLER SYSTEM 1/8" =11-0" Sprinkler Legend /FRFl(I-IT APPROVAL: City of Tukwila SIN QTY. K SPRAY ORIF. 12 5.6 Pendent W 23 5.6 • Pendent W Total = 35 FIN. Chrome Chrome TEMP. 155°F 155°F CONT. NO.: K80355 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 07/09/08 7102 180th AVE NE, STE A-105 - REDMOND, WA- 98052 Lic. # WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUEIAUSTINI DALLAS FOECATURIDENVERIDULUTH/HOUSTON /KANSAS CITY LAS VEDAS IMINNEAPOLIS !PHOENIX / PORTLAND IRAPID CITY/ST. PPM /SALT LAKE CnYISEATTLE Phone: 425-881-0100 Fax 425-881-3030 JCPenney 1200 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SYMBOL LEGEND a gig OUT OF SCOPE OF WORK OUT OF SCOPE OF WORK • Arta of Work $ ♦♦ OUT OF SCOPE OF WORK OUT OF SCOPE OF WORK 6 � OUT OF SCOPE OFWORK OUT OF SCOPE OF WORK REVISIONS FIRE SPRINKLER SYSTEM UPPER LEVEL 1/16" =11-0" Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE - . HYDRAULIC REFERENCE POINT HANGER SYMBOL BRANCHLINE RESTRAINT 7lAIDK R3615 12 5.6 Pendent Chrome 155°F F1 FR Semi-Rec 3 APPROVAL: 5 7 ParrAir 9 11 ME NM City of Tukwila PHASE I Total = 12 CONT. NO.: KS0355 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 07/09/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA- 98052 Lic. #: WES I bSF136QF WESTERN STATES FIRE PROTECTION COMPANY. OFFICES LOCATED ALBWUEROUE /AUSTIN 1DALLAS, DECATUR l DENVER /DULUTH/HOUSTON /KANSAS CITY LAS VEGAS /MINNEAPOLIS I PHOENIX IPORTIlND !RAPID CITY/ST. PAUL/SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 MATCH LINE (ZONE 2) MATCH LINE (ZONE 9) JCPenney 1200 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM UPPER LEVEL r 1) CL U Adam Kantner Sill,I% FP -a 5 Bayley Constru 118" = ! I • Adam. Kantner Bayley Construction SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN 4 -WAY EARTHQUAKE BRACE R3615 QTY. 12 K 5.6 SPRAY Pendent ORIF. FIN. Chrome TEMP. 155°F MFR./MODEL Fl FR Semi-Rec APPROVAL: City of Tukwila HYDRAULIC REFERENCE POINT Total = 12 CONT. NO.: KS0355 HANGER SYMBOL BRANCHLINE RESTRAINT DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE 07/09/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 WESTESF136CIF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUOUSRCIUE /AUSTIN DALLAS 1 DECATUR / DREIER / DULUTH / HOUSTON !KANSAS CITY LAS VEGAS /1111WEAPOLIS PHOENIX / PORTLAND I RAPID CITY/ST. PAUL /SALT LAKE CITY1SEATTLE Phone: 425-881-0100 Fax 425-881-3030 JCPenney 1200 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM FP-7LLI yr A . A " I.dii[, Itr:1111111PI.%<2. A AL Air tildleilii. -4$11111E-litalliidiliingli i iiiiiill ASIA Ai Ar .1: .:4_,_ir 01111111.1111FiligratigettrigligansinitiMinirtiiiiiitaiiiiraretWiliiiikliiiiiiiiiliniligiilipliP1 -- 111111/111.111111111PinlimilIMPLINFIIIIIIIIIIII/1111111111111101/111/ 11/1111111111 lirtglinirdirlipiriPiiiiiriliniglrair ,-----H i fillillidp11111141111/111/111111121A111104.111N11111 Ilitlirlariti1111111 ilitirrammorditawrimismitin iiiiiiirdmprig 4141 Ardiiimmitimintritapiiiiiiiiiiiiiiira -,1404Arpiiiiiiiiiiiiiiiidiiiiiiiiiiiiiimmininpiriiiiiiiiiiikailii 11111Mild11101/11111111111111111/11111011111/111/1111014•110 pi Ardp111/11111111/1111111/1511111talielirdputiusrpirmirip1111_11,1111111111111111111111/1111 111/11111110111111111 r!7:1 Pr I i ro Adiolii-_ristimmi r .,; P" pirimpoiliiiipriortaboicidi P", Pr IF r ip, SCOPE OF \adiditio,diodiripiiirogdpreParlipurAmilionamotworirtimmorm 1111111111111/11/1111/11v11/111 Fir Air'Ail t Airdeiiipuriarimitora ivy iimpirrArioramiewmordstEL woRK, ' *3w - , ! i /B11111/d111111111/1 11111111 NAB .111111111r 111111111 /I IriariffrifiAir1111111111111111/ 1111111111111111dIA Az ccli I A 10411111P1Plir. All A - IMF." '!..4411P r KIEV .../' ° 4. mg_ lit 11,11iFrPtireirEr OUT OF 1111111.1111111011' A A .4 A Alb_ 11 A 49 . ; 4. A gm _Aid 014111jr. 4 , 4 rA i ' 6°' ' _ sci(zilF)11Firoripromiiit :' :• 1 HiciniffirdiairdowAririmitios: Ar ,,,, A Aigi Atd_Adtpr pApitrAddit_ Advardiroplpipit di • . , r-.' lino priiiipilpropplioniir 41kt! ip.illoyAilllimill, pop" ploproprigraprippApiorolepA4541fimpurropA. i 1-Tiskolip,Aptipria.fiwpApAprdpAc, SCOPE AirdpijapAtETELLAdi Ap4p.iiiip diosodoriplisiditipPup pAdpAd "ugh, --- rnvyvAd,3 .::.:t:_.•,1 liippoilo RAO1Pd1/111411111/111111111PPrilltilFfMtr, IPTLI0111911111!‘111.0141,111Ad114111111111111114.1111akk/. '.-,, Nita 1414,11/1111111110/1141111( r.litr,_..,.....riru • t: . ....: „„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„ Alr4IpP!' 1_ I _ s'' -v zzz'-'u,''','`'2r 1 „„„„„ .r.v,.„,„..,,,_...,„..„..,,t.,.„,..i.._,.:17,:,,„.„.,,„.,;.,,..,..,rirTiJ.:.,:,,,,.„-J..:,..,,,.„....,....n. 4 - zw.;y4'""''''"'"_,Artr. '''''''' ''''''. . ''''''''''''El '''''"""'Alii' '°'"'-4' '.- - ................... .„,..,,,,,...r., v A0 1 1- 0 ---- ---M t4 ____ a \k, 6 m 1 ..,-. I .4a,.._ 0 a 0 ....61 11.1- p\,,4 PI .cli- N Mi " " - A i:4 -Tr 2:4 ...7..1..ri,,,itir....,,,It..,.,.:,„,.,„ ;-. ____I -i" wr ' * FAME' ' +•LJ r r .'.:ilirmiii PillrallrillaingillinlidliAN A 4 - - A Lir 1 Ar9f IA_190c._1_ TIPIPP111111FINF A A 4 Al ikmelz A 4 Al !,. _ _.______i T----1-1111010P;11110PF I 4 , iii Es , 4 ,i3 . ir rA ,. _ 'F- "1111p1/1110/111111111.11/1111Mr ' I-- ' . 1 In 1 . A AtA1121411A4 Al AM it! _...,,i i -1:: _. A/C:AA' .4111114/1 Aii : r mA izA izA izA 1 ' 1 iiipttiiiiiiiktliiiiiimmin LI -t, iiiiiiiiiiiiiiirmiiiiiiiiiiipitirdi iiii_lo A lu) iii to ! _ii; t.•77---i----.-:7-7,-----gA-4 ' r -L,..,,,-., "P'' 1 4Dxs-i : --i L. J.ILILL:::_. L,11 11111Er 111111111111114111111111111.1 :__, 01110111117 Adir111411111/1//11111111111111111111111111r .1-.,:.,11.,_:„,.._,,, 1 . i s I! ' ' :- 111111111111FilfillIr liffill111111111111.11111111111i111111111/11/1111Ril = I Aill'''. 4/111111111111 i.,..,, , . 7 ._:_rT7--:11-,-;--f- __ 1 .. ' - - .L-4;7— I 12ij --i- 'MA—J.:0 MA MA 111111111111111111111! H i 1 MITINIVINIA111111 111111111111/11 11111111i .11Pii1111.411i11/111111 4) 1 . a , 1 - - mr4 r m woo r . ' ' 111F1111111111111111r41111111111/1PME .1 :'! ------------ -II- "Mr ! 1 Air EIPI Nor pr IF- Ply i Oa IIII-P 014"0011PPPPI , 'i* r Andriminimiraramormin d . . * * * Al Ald AifiAlil 111.4 ,„ ...4041 .4111 441.40.1 1 7 IMP 1111 1111111111.1,111111111101 II A_ 40 • 11,1110111111111111111111111111 11111111 II Ar 1 A _ .411111 ' .211.1111"1411V 1 ! AK titi dir-''w--1110--.. Airy Aiiiiiiii,,,-AirliFilir: -"AAA PI 1 I Pr / ri bill ApPAI 1 ACOMENIMErditairth,AriiiiNgliffir Addlaii--- .:-.-,::-. , : ! Aptlerapaggiiiiiii AllIprill011.111111111.111111111/1111111RIF AMINO /1/111111111111111111110101111i1.1111111/11( -)-'d / ! iiiinionommer Adillieriptipidril/11/111111111111.14111011111141111111u11/1111pd1111111111gAmmiiduiziriunimialiorr'ou-70F Paripliiiir 0, Aipirmireduriminpriiiiimporilidir' riiiiiiiiiir SCOPE OF Ti14011,111111/1111P511 Atimrdmiiinisiiiiiiiidir ' lkspi0,1111/1411.111d11111r4W11111111111-411r AMIIIIIMININFINTINFAIMPIIMI..,' OUINIEN - - All 1 41111.11 1.10:1111 ,E' ingiimile lipapA_riii iiiiimmAiiiiiikr-in-iiit-r-y_ : iipAririsizz4roulaiiiinertit-AricWr la 1 I 1 1 '1 ,,iir OF i gor -(::,7.AidloriviRriir-AAN1111111d 1 uUT AgratztirAwil I SCOPE OF ,:c4IptlifilWV-A.1072: 40701Aillit-YAMINIAIMPAION A ,:; ! IA Apr111011141111B11141111114Alay w°RK i, Al Arldritrori AdirrAillirlifillUANOIW- :'ADAIIIIIIIIPARIP1111/1111/ ....;w ..'''''• 1 ' PLAAr .-----;-L 141111p11111pd11111 iAdiparrani -HLE. !A AdrdlrmrNll ,--- 111,0•111111111141111" A011111 INNIU111/11111/111 I ' 411110111111,p1 4111171111111111, ulna INIIIILY.1111011111f AINIAll IF 441114101111 ANA% . mc;IEIArdimplingroild Idavoi o,1riiiiimisirodscir Jpiiiiiii_widiPardiPtivi imitiiiiiiiiiiiiiiiiminsiiiir r Anditt AftrakirLir Airmonirr fp AI Airdrie, Air: A ' A A ii• ailirintintanrir AiiiiPArdiiiiiin MEW AdriutArallffir . . . . , 4 - - ? , dird, Air A liPir; Aiiiirair.,AiddiiiiiiriLiiiiiirritiiiiisriPs" Allrirrdr wcArldirdridlelrardi .. , . ' 41 , i a,- •AtI , . : : . :. 4 r AA N 4 re- r ow4 ail w 1 r„ Wira 441111 ; , r' 4 '''''.1:.. AMITIONIr 1 AILIIIIIM11111 MEM r: „..: 1 r r r r r rIP r Pir ir r Pr Priy,14 I PAT FIRE SPRINKLERSYSTEM 3 5 7 9 1 1 Fr r r Frr Pr r Ilr ,A;-:::ifi3O 4 • - •A A : 0 .'. • 118" = ! I • Adam. Kantner Bayley Construction SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN 4 -WAY EARTHQUAKE BRACE R3615 QTY. 12 K 5.6 SPRAY Pendent ORIF. FIN. Chrome TEMP. 155°F MFR./MODEL Fl FR Semi-Rec APPROVAL: City of Tukwila HYDRAULIC REFERENCE POINT Total = 12 CONT. NO.: KS0355 HANGER SYMBOL BRANCHLINE RESTRAINT DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE 07/09/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 WESTESF136CIF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUOUSRCIUE /AUSTIN DALLAS 1 DECATUR / DREIER / DULUTH / HOUSTON !KANSAS CITY LAS VEGAS /1111WEAPOLIS PHOENIX / PORTLAND I RAPID CITY/ST. PAUL /SALT LAKE CITY1SEATTLE Phone: 425-881-0100 Fax 425-881-3030 JCPenney 1200 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM FP-7LLI yr Gener•i otes 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing tire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. VICINITY MAP DETAIL NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III N / HILTI Kwik Bolt II Drilled Anchor / \ Ii Cut Rod Lgth Rounded to Nearest Inch Rod Coupling —� l All Thread _ Rod — 111111 d Swivel Ring Pipe CL Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE FIRE SPRINKLER SYSTEM 118"=1'-0" TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE LEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE FIG. 909 SWIVEL SWAY BRACE FITTING 3/8" KWIK BOLT (2 114" EMBED LENGTH) FIG. 1000 -�' "FAST CLAMP" SWAY BRACE ATTACHMENT O LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE FIG. 4A PIPE CLAMP FOR SWAY BRACE ( LATERAL BRANCHLINE RESTRAINT 3/8" KWIK BOLT (2 114' EMBED LENGTH) FIG. 909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT BRACE PIPE IDA] NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN 4 -WAY EARTHQUAKE BRACE R3615 QTY. 12 K SPRAY ORIF. FIN. TEMP. MFR./MODEL 5.6 Pendent Chrome 155°F F1 FR Semi-Rec APPROVAL: City of Tukwila HYDRAULIC REFERENCE POINT Total = 12 CONT. NO.: KS0355 HANGER SYMBOL BRANCHLINE RESTRAINT DRAWN BY: Adam Kanter SPRK ON SHEET:. SEE LEGEND SPRK ON JOB: DATE 07/09/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE /AUSTIN / DALLAS/ DECK= /DENVER /DULUTH /HOUSTON / KANSAS CITY LAS VEGAS/MINNEAPOLIS / PHOENIX /PORTLAND /RAPID CITY/ST. PAUL/SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 j) U Adam Kantne. Bayiey Construc JCPenney 1200 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM REMOTE AREA ORDINARY HAZARD GP 2 .20 / 2000 SF 12 11/4 7-101/2 13 11 14 1/2 40 7-101/2 16 —$ 0V22 1-0 1124 is 1 ( 7-101/2 1V4 ( 7-101/2 17 11/4 7-101/2 hydraulic calculation reference 4 \/\f/Exim\Gipi/zickamV BIN CATWALK DECKING PENDENT SPRINKLER W/ HEAD GUARD BIN mezzanine section 1/4" _i 1'—O" AI I Ili.► :Jr »1w ' 10 T 71 114 =4 •!114 -1;41 . 114 1..L4 7 r Y4 1 114 r 7 1Y Y • :.1 • wpm MN= Ki•1J�i a: •1 114 10Yt= •tor Y4 114 0 0 0 n) \'4' CONTROL. VALVE, FLOW SWITCH, DRAIN 4' TO UPPER LEVEL (W/ FLEX COUP 0 T CONNECTION TO EXISTING 4' APPROX 20' OF 4' PIPE AND 60' OF 6' PIPE TO SIN # SPRINKLERS l EXISTING 6` LOWER LEVEL STOCKROOM - SHOESTORAGE under mezzanine sprinkler plan QTY O TY3211 TYCO TY -L STD RESPONSE STD COVERAGE BRASS PENDENT K=5.6 165' • 106 W/ HEAD GUARD / CPI o Retaining Strap S AM CLAMP QL L THREAC RCD HANGER RING ,Retaining Strop BEAM CLAMP BEAM CLAMP STS A=LL THPEAD ROD GENERAL LEGEND 4- —D —4 0 BOD BOB BOJ FOS FOW EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPLING ( UNLESS NOTED ) CAP PLUG CENTERLINE HYDRAULIC REFERENCE POINT CENTERLINE PIPE TO BOTTOM OF DECK CENTERLINE PIPE TO BOTTOM OF BEAM CENTERLINE PIPE TO BOTTOM OF JOIST FACE OF STUD FACE OF WALL FOC AFF CH R.C. E/C C/C C/E GG TG TxF AIR FACE OF CONCRETE ABOVE FINISHED FLOOR CEILING HEIGHT REDUCING COUPLING OUTLET COUPLING WELDED OUTLET 'FIT' FITTING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALSO 'cr) THREAD/FIT' (ALSO 'Fxr) ALL -THREAD ROD EX,STI":G k!A:L ENTRY AREA OF WORK l l ACCEPTED Without Comments As Noted in Red 0 Per The Attached Letter These plans have been revie .•ed by The Tukwila ila Fire Prevention Bureau :,v4h current city standards. Acce .- .a *_� �-t to errors and omissions which do riot rituLhonze vio tons of adopted stanaaras and os-- .nar,..es. T^z responsibil4 for the adequacy of design resZs totally with the designer. Additions, deletions or revisions to thee drawings atter this date will void thie, acceptance and will require a esubznittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire, Prevention Bureau. Date: `� O By: SUPPLYING UNDER I4E7Z AND ROOF SPRINKLE% (SE 2 OF 2) EXISTING B' WET RISER TUKWILA FIRE DEPARTMENT Please call: 575-440Z and give this job No. 0 7- s -b3 and exact address for shuts gown or restoration approval. ( h eA,'E CO l pc isc f (,Som 4 -Qck "S s 5 c 1 - S pr,hk1Cv vaks %4h 11" 4✓+ CbuY l,/ .4A—` r -i- Lt-11ft- GENERAL NOTES SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 AND F.M. GLOBAL REQUIREMENTS ALL MATERIALS SHALL BE NEW AND U.L. LISTED AND F.M. APPROVED THE INSTALLATION TO BE IN ACCORDANCE WITH MANUACTURE'S RECOMMENDATIONS AND FP GLOBAL RECOMMEDED GOOD PRACTICES FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. X13 & F.M. FURRIN CUTTING OR PATCHING TO BE BY OTHERS LOWER LEVEL CALCULATED .20 / 2000 SF W/ K=5.6 SPRINKLERS 1' - 11,i' THREADED PIPING TO BE 'DYNA-THREAD' 2" - 4' GROOVED PIPING TO BE 'DYNA-FLOW THE F.M. GLOBAL HOT WORK PERMIT SHOULD BE USED TO MONITOR ALL WLEDING, CUTTING, ETC. DURING THE INSTALLATION OF SPRINKLER PIPING THE F.M. GLOBAL RED TAG PERMIT SYSTEM SHOULD BE USED TO MONITOR ALL SPRINKLER IMPAIRMENTS ALL VALVE CLOSURES SHOULD BE CALLED INTO CUSTOMER SERVICE UNE AT 1-888-216-9322 SEE 2 OF 2 FOR ZONE OF INFLUENCE EARTHQUAKE CALCULATIONS A 5/1/07 REVISE CALCS FOR UNDER VEIL TO ORD HAZ GP 2 ® 4/19/07 IEY1SE PER FACTORY MUTUAL REVEW OF 4/17/07 © 4/3/07 REVISE PER FACTORY MUTUAL REOUIMITS key plan no scale FILE CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MIL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 JCPenney STORE #0696 southcenter mall tukwila, Washington DATE: 1-07 DRAWN: C.A. SCALE: AS NOTED 10F2 tft REMOTE AREA ORDINARY HAZARD 30 / 3000 SF 4 1 EARTHQUAKE BRACING CALCULATIONS NFPA 13 CH. 9 2002 ED. WI 11A 02-1 LATERAL BRACING WORSE CASE SYSTEM LOAD: DIAMETER TYPE LENGHTS 11/4' DYNATHRD 23' X 4 DYNATHRD 3' X 4 4' DYNAFLOW 28' TOTAL WT/FT TOTAL WT 92' 2.54 233.6 12' 3.22 38.6 28' 10.86 304.1 TOTAL WT OF PIPE 576.2 # HORIZONTAL FORCE FACTOR = .5: 288.1 # SAFETY FACTOR = 1.15. 331.3 f = _ 200 ANGLE OF BRACE iS 30' TO 44' FROM VERTICAL ALLOWABLE LOAD FOR 1'.SCH.40 PIPE (7'-0' MAX. LENGTHS) IS 1767 1 ALLOWABLE LOAD FOR THROUGH BOLT — STEEL (ORIENTATION 'A') IS 1600 It! MAX LOADS ATTACHMENT TOLCO MODEL 11000 SWAY BRACE — 1'-4' PIPE TOLCO MODEL 1980 SWIVEL TOLCO MODEL 1907 4—WAY SWAY BRACE TOLCO MODEL 1825 BAR JOIST SWAY BRACE TOLCO MODEL 1825A BAR JOIST SWAY BRACE 11'-6 92 SF 92x.3-27.6GPM 7.00 PS END HEAD PRESSURE MINIMUM LBS 2015 2765 655 2015 1265 ADJUSTED PER 9.3.5.10.3 1007.5 1382.5 327.5 1007.5 632.5 12- DEFLECTOR DISTANCE MAJ011UM r ° �' =133.'` t Pa • • —s^ r I i _..�_ - —1 —_, =• 8— Wit_--qI =�w, �� -rte —; - �_ ---. ▪ .. =:- -_a4 — — • FROM BELOW EQ CALCULATION ZON OF INFLUENCE SEE CALCULATIONS ABOVE I SPRINKLERS QTY i UPPER LEVEL STOCKROOM roof sprinkler plan 1/8"- = V_0„ EARTHQUAKE AND SWAY BRACE POINT -OF -ATTACHMENT -- FIGURES • 4 WAY r 25' I EQ 0 TY5111 TYCO ELO-231 STD RESPONSE STD COVERAGE BRASS UPRIGHT K=11.2 28T. 48 i UPPER LEVEL STOCKROOM roof sprinkler plan 1/8"- = V_0„ EARTHQUAKE AND SWAY BRACE POINT -OF -ATTACHMENT -- FIGURES Q WORMIER FITTING (AEGON pmi) —SWAY BRACE PiPE PEE PLAN) PPE BEND BRACED LATERALLY SWAY BRACE ATTACHIENT AFCON %02O CLAMP PAN soim LA TERAL BRACE SCiJE. NTS BRACE PrE 1• x SEE CALM/ PLAN SYLIBOL , PPE BERM. BRACED LCNOTUOINALLY FASDER SWIVEL FITTING (AFCON grrn �AFCON CtAYµt0 FRtCflON P L ONO/TUD/NAL BRA CE PIAN SYMBOL -r Ip SCALE NTS STAY BRACE ATTAQHIENT MOM PO MIR PIC OAP FAY BRACE PPE SEE PLAN) SW/VEL FITTING (AFCOI X77) 4 W Y BRACE SCALE. NTS MIN Q SWAY BRACING SHALL BE INSTALLED BASED THE FOLLOWING INFORMATION: Flexible Couplings Shall be Installed as Follows- Lsted fade pope coupings ping Fated end Dee shd be aaeded as lean pots to dor ihdri lid sections of ping 21/2 n. (64 own) or f rger to more f a enbdy rdh the ix traiid secimns of the bucking to winch I a attacJted. Couplings shd be waved to concde r th struct rd separais:e rdhm a bulking. The liable couplings shall be installed os followz (1) J hn 24 it of the tap and batten ofd revs. ExceptLn Na 1: M risen less then 3 ft e le gth, feeble =gags owe panelled to be omitted Ex cepbon No. 2: h risers 3 to 7 ft n length, ane iatie cooping is odecnate. (2) Mho 12 iL above c d rthm 24 it below the Poor a multatary buidngs %%eh the ledie caring baler the Igor it atwre the tie -n mom to the mon srpl)mg that foe, r lade oar&g shd be proaded on the what whom of the tris --1I Denq (3) On both odes of canaete or masonry rds Choi 1 ft of the ed surtace. Exocepbart FIe, bie ppe mph= owe not rued There dearonce acrd the pipe a prordd o accadaxe rdh NEPA 13 9.3.23(3) - 4 Wm 24 n. of buil g exoarsrm pmts (5) i a1 24 in. of the tap and bottom of drops to hose HLAs, root spars, s and names, regattas of pie sae. (6) ram 24 it of the top of drops eaearng 15 ft in length to portions of systems supping mare Blur one wider, reFdess of Fine (1) Ad bei y nt mec ateapo Ab arrts of support for o riser or other whim! Pee. NOTE: 1) SWAY BRACING ATTACHED TO CMU BLOCK SHALL BE THROUGH BOLTED. 2) PER NFPA 13 9.3.5.9.3 - SWAY BRACING ATTACHED TO WOOD SHALL BE THROUGH BOLTED, EXCEPT WHERE IT IS NOT PRACTICAL DUE TO THICKNESS OF MEMBER OR INACCESSIBILITY. IN THESE CASES LAG SCREWS SHALL BE PERMITTED. NOTE: PER NFPA 13 9.5.3.5 1) LATERAL SWAY BRACING SHALL BE ALLOWED - TO ACT AS LONGITUDINAL BRACES IF THEY ARE WITHIN 24" OF THE CENTER UNE OF THE PIPING BEING LONGITUDINALLY BRACED. 2) LONGITUDINAL SWAY BRACING SHALL BE ALLOWED TO ACT AS LATERAL BRACES IF THEY ARE WITHIN 24" OF THE CENTER UNE OF THE PIPING BEING LATERALLY BRACED. LISE w RSi II= (3) till ISLES ' 4' 4 WAY r 25' I EQ 4' LATERAL ALL FIGURES OCct W Z WHERE SWAY HANGER i FASTENER BRACE LLI ¢ _ WHERE SWAY _ HANGER i FASTENER BRACE ce 41 1.3 a _ WHERE SWAY HANGER I FASTENER BRACE i FIGURE B - BRACE FASTNER IS EVEN WITH POINT OF ATTACHMENT E E FIGURE A BRACE FASTNER IS EVEN MATH POINT OF ATTACHMENT FIGURE C BRACE FASTNER IS EVEN WITH POINT OF ATTACHMENT MINIMUM 1/2 DEPTH BEAM BUT NOT <3 IN. FORWOOD BEAMS OF MINIMUM BEAM FOR 1/2 DEPTH OF BUT NOT <3 iN. t. MINIMUM 1/2 DEPTH OF BOA WOOD NOT <3IN WOOD BEAMS ix LJ Z S WHERE SWAY HANGER et Z = WHERE SWAY HANGER tx ZI _ WHERE SWAY HANGER I FAST—TZ BRACE _ IS BELOW i FAST R . ER FIGURE D BRACE FASTNER IS BELOW POINT OF ATTACHMENT FASTENE�i BRACE FIGURE F BRACE FASTNER iS BELOW POINT OF ATTACHMENT FIGURE E BRACE FASTNER POINT OF ATTACHMENT LIFASTENER a _ WHERE SWAY HANGER BRACE La ¢ S - WHERE SWAY HANGER IFASTENER BRACE w a S -------- WHERE SWAY HANGER 1FASTENER BRACE . _FLGURE_G BRACE FASTNER IS ABOVE - POINT OF ATTACHMENT 7 ` ' ► FIGURE H �' - BRACE FASTNER IS ASGVE POiNT OF ATTACHMENT , i ` -- FIGURE —t— - - ---- BRACE FASTNER IS ABOVE POINT OF ATTACHMENT Q WORMIER FITTING (AEGON pmi) —SWAY BRACE PiPE PEE PLAN) PPE BEND BRACED LATERALLY SWAY BRACE ATTACHIENT AFCON %02O CLAMP PAN soim LA TERAL BRACE SCiJE. NTS BRACE PrE 1• x SEE CALM/ PLAN SYLIBOL , PPE BERM. BRACED LCNOTUOINALLY FASDER SWIVEL FITTING (AFCON grrn �AFCON CtAYµt0 FRtCflON P L ONO/TUD/NAL BRA CE PIAN SYMBOL -r Ip SCALE NTS STAY BRACE ATTAQHIENT MOM PO MIR PIC OAP FAY BRACE PPE SEE PLAN) SW/VEL FITTING (AFCOI X77) 4 W Y BRACE SCALE. NTS MIN Q SWAY BRACING SHALL BE INSTALLED BASED THE FOLLOWING INFORMATION: Flexible Couplings Shall be Installed as Follows- Lsted fade pope coupings ping Fated end Dee shd be aaeded as lean pots to dor ihdri lid sections of ping 21/2 n. (64 own) or f rger to more f a enbdy rdh the ix traiid secimns of the bucking to winch I a attacJted. Couplings shd be waved to concde r th struct rd separais:e rdhm a bulking. The liable couplings shall be installed os followz (1) J hn 24 it of the tap and batten ofd revs. ExceptLn Na 1: M risen less then 3 ft e le gth, feeble =gags owe panelled to be omitted Ex cepbon No. 2: h risers 3 to 7 ft n length, ane iatie cooping is odecnate. (2) Mho 12 iL above c d rthm 24 it below the Poor a multatary buidngs %%eh the ledie caring baler the Igor it atwre the tie -n mom to the mon srpl)mg that foe, r lade oar&g shd be proaded on the what whom of the tris --1I Denq (3) On both odes of canaete or masonry rds Choi 1 ft of the ed surtace. Exocepbart FIe, bie ppe mph= owe not rued There dearonce acrd the pipe a prordd o accadaxe rdh NEPA 13 9.3.23(3) - 4 Wm 24 n. of buil g exoarsrm pmts (5) i a1 24 in. of the tap and bottom of drops to hose HLAs, root spars, s and names, regattas of pie sae. (6) ram 24 it of the top of drops eaearng 15 ft in length to portions of systems supping mare Blur one wider, reFdess of Fine (1) Ad bei y nt mec ateapo Ab arrts of support for o riser or other whim! Pee. NOTE: 1) SWAY BRACING ATTACHED TO CMU BLOCK SHALL BE THROUGH BOLTED. 2) PER NFPA 13 9.3.5.9.3 - SWAY BRACING ATTACHED TO WOOD SHALL BE THROUGH BOLTED, EXCEPT WHERE IT IS NOT PRACTICAL DUE TO THICKNESS OF MEMBER OR INACCESSIBILITY. IN THESE CASES LAG SCREWS SHALL BE PERMITTED. NOTE: PER NFPA 13 9.5.3.5 1) LATERAL SWAY BRACING SHALL BE ALLOWED - TO ACT AS LONGITUDINAL BRACES IF THEY ARE WITHIN 24" OF THE CENTER UNE OF THE PIPING BEING LONGITUDINALLY BRACED. 2) LONGITUDINAL SWAY BRACING SHALL BE ALLOWED TO ACT AS LATERAL BRACES IF THEY ARE WITHIN 24" OF THE CENTER UNE OF THE PIPING BEING LATERALLY BRACED. LISE w RSi II= (3) till ISLES ' 4' 4 WAY ALL FIGURES 25' I EQ 4' LATERAL ALL FIGURES 40' 1---r 4' LONGITUDINAL ALL FiGURES 80' NOTE - SEISMIC BRACING TO BE INSTALLED AS PER NFPA 13 ACTUAL LOCATIONS MAY VARY DUE TO FiELD CONDITIONS GENERAL NOTES SPRINKLER SYSTEM DESIGN PER N.F.P.A. X13 AND F.M GLOBAL REQUIREMENTS ALL' MATERIALS SHALL BE NEW AND U.L LISTED AND F M. APPROVED THE INSTALLATION TO BE iN ACCORDANCE WITH MANUACTURE'S RECOMMENDATIONS AND FP GLOBAL RECOMMEDED GOOD PRACTICES FIRE. SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND iLSTED IN ACCORDANCE WiTH N.FP.A. j13 & F.M. ALL- .LECTRiCAL, PAINTING OF PiPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS LOWWR LEVEL CALCULATED .15 / 2000 SF W/ K=5.6 SPRINKLERS 100 SF MAX PER SPRINKLER / 8'-0° CC IN AISLES 11/` THREADED PIPING TO BE 'DYNA—THREAD' - 2" « 4' GROOVED PiPING TO BE 'DYNA—FLOW' THE;F.M. GLOBAL HOT WORK PERMIT SHOULD BE USED TO MONITOR ALL WEEDING, _i;UTTING, ETC. DURING THE INSTALLATION OF SPRINKLER PIPING THE M. GLOBAL RED TAG PERMIT SYSTEM SHOULD BE USED TO MONITOR ALL SPRINKLER IMPAIRMENTS ALL VALVE CLOSURES SHOULD BE CALLED INTO CUSTOMER SERVICE UNE AT 1-888-216-9322 —1 A1,4/19/07 REVISE PER FACTORY U IJAIAL REiD OF 4/17/07 4/3/07 FUSE PER FACTORY MUM. REOl,1Rf]O 1S C!) u CD Li CD �_ —J Cn CROWN �- FIRE PROTECTION INCORPORATED P.O. BOX 12113 IMI L CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 JCPenney STORE #0696 southcenter mall tukwila, Washington DATE: 1-07 I DRAWN: C.A. I SCALE: AS NOTED i 2 OF 2