Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 1010 SOUTHCENTER MALL - DOWN EAST OUTFITTERS / AT&T - PERMITS AND PLANS
1010 SOUTHCENTER MALL ASSOCIATED PERMITS 16-F-229 16-F-160 16-S-221 11-S-122 EL16-0963 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** f--� King Co Site Address: \\ C C"_)01\ --\Cc nr\tx\l Tenant Name: 'l oto \ Date application accepted: . Assessor's Tax No.: Suite Number:_• Floor: New Tenant? rzi, Yes 1:1- No Property Owner's Name:'M! S*- \P\ C-en"e r Mailing Address: 2-6CD DO"\-ViCeirl-1elf I Y `o' \ Ato CONTACT PERSON -if there are questions about the submittal. Name: Cf ic-' _ O gni.lr1d Company Name: City State Zip Day Telephone: LA2L . q • 7100 Mailing Address:X \ \ m �\\ C`re etc / �� gRDS2- City c Statee ZiE-mail Address: 30,\DA@. CX * C-�j7. Coro Fax Number: L 7c5 yg . Ro vs' Valuation of Project (contractor's bid price): $ i n Scope of Work (please provide detailed information): P v3 (R 4jre, cer in 'y, e (S) \Y� splint\P p O 1 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO ' ED AGENT: Signature: � �� /� Date: 5/1/1 I Print Name: je cs/ t Ra4irkSoi7 Plan Permit App.doc Day Telephone: 1-12-54-1 g I' 7669 5/14/10 TFD FP Form 8 410"44, 4 ti SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: D\ L i Gou'ft'ef \ f'X' Suite Number: , Floor: Tenant Name: Property Owner's Name: New Tenant? ❑ - Yes ❑ - No Mailing Address: City CONTACT PERSON -if there are questions about the submittal. State Zip Name: _.C� lCek �" �_��'(� l Day Telephone: L\? "T 1 '7(1j Company Name: C (\L2f V\fE? _ \ ` kY) \ Mailing Address: Q T%02C \2\ 1b m (yet_ t uJ� q `; City ,( _ E-mail Address: 1 �1♦11. 11 Fax Number: 1----Y2,51)'S ate ' I ' Zgaig e,—' G' Total number of new/relocated devices or sprinkler heads: 22 Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. _ I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Plan Permit App.doc Date: %0/Cfh6 Day Telephone: 12S 410 '76(0,T 1/2/13 TFD FP Form 8 44.ttsw44 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. P/I) 0 **PLEASE PRINT** SITE LOCATION !! Site Address: * s O u P�T CX j�l� c� King Co. Assessor's Tax No.: 1 2 0 Z- Li 7 -00 WOO p'?i", " Tenant Name: ATT ' , B Lit ' i C? v7ferr Suite Number: ) 4O Floor: New Tenant?[✓� Yes ❑ - No Property Owner's Name: P✓v per *j Tor X Oe p +- Mailing Address: P O 030 X ! 3 047 o ('U r I S! acl City CONTACT PERSON -if there are questions about the submittal. Name: A-; r1 S) rj D S e Company Name: CliA a,vd l A h iAJ /4 Z d State Zip Day Telephone: Z0"(v—(OZZ-cocci S xZlo� c/ls vylS /h f Mailing Address: /% 3 1 c+ Ave <7,14 5'evl , -1 City E-mail Address: a1 C I D 52 ( 11 a v�,I i /I Yl 5 (f ')1 , co ✓ 'Fax Number: 2_06 — ,/ 7-- Con ctor's City of Tukwila 21 7 (P 3 Business License number: A IA 5 Bolo ve \r‘� Total number of new/relocated devices or sprinkler heads: 17 Valuation of Project (contractor's bid price): $ 9 7 3 o Scope of Work (please provide detailed information): t 1 ✓[ A'1 A eve? Te YI a !f)i / ply �% VD ✓e rner) �- WA- 4)813V State Zip 34I-goj?_g ---092/3S1-1 i -hem PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 1 is/2oJ1 L Print Name: /11 .1/1 5 Day Telephone: 1.06—ea 21 SLI 5 X 261 Plan Permit App.doc 8/22/14 TFD FP Form 8 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION 3 �� ti %� i'C w,r�,�,�r 5 0 u4i-, C e i) Lir m cl lTan gCo. Assessor's Tax No.: Site Address: V7/41261344041/114kr./10401) Tenant Name: ATT Ce Property Owner's Name: 1 f t4 i t? 1 fJ 92_02_97-000 Suite Number: j % 4 Floor New Tenant? Q - Yes ❑ - No Py -o pe7;4 x De p Mailing Address: Po A3i, X J 3041-10 CIA ✓1 s �' of c t City CONTACT PERSON -if there are questions about the submittal. Name: 4-t V) c) -61...j ('ICS-£' Company Name: 614 arrf1 An ">F l.(W1 t'�j i y �r v j S .,I l'i Mailing Address: /'% 1-i 3j c4- �JzL.4 1--11 e -f-i.e L j City E-mail Address: 6 C t O 5e (Vq ave til r? 5 �1-1A1; rlrj , L 0 f'3'F ax Number: 2 U W Con ctor's City of Tukwila Business License number: jj ir1 5 - Day - wit- 9 lo State Zip Day Telephone: 2.04" — {��.2 ! s x26') 11114 e"Sj3Y State Zip NICET III number: Total number of new/relocated devices or sprinkler heads: j 7 Valuation of Project (contractor's bid price): $ 9/ 7; 0° Scope of Work (please provide detailed information): f -7- i sit° ft r ! P Y? a 071- ) P14 J'l vv vf YYI Yj �•. d rhG�Y4 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Plan Permit App.doc 8/22/14 Date: f t2/'�-tJ1/1 [v? Day Telephone: 1.0t, —to 77_ 'C2 S L/ qX 261 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Down East Outfitters 1010 Southcenter Mall Permit No.: 11-S-122 Date: June 2, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206)971-8718 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. 9 o t • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: AT & T 1010 Southcenter Mall Permit No.: 16-S-221 Date: October 21, 2016 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 21 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). .ti • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. e- l Data Sheet Specialized Devices Air -Duct Housings (FDBZ Series) Models FDBZ492, FDBZ492-HR, FDBZ492-R and FDBZ492-RP {with FDBZ-WT and FDBZ492-RTL} ARCHITECT AND ENGINEER SPECIFICATIONS • Four (4) models available • Addressable and conventional with and without relays • Compatible with Siemens — Fire Safety conventional and addressable fire -alarm control panels (FACPs) • Magnet test feature with the Model OP121 conventional detector • Design for air -velocity range of 100 to 4,000 feet -per -minute (fpm) FDBZ-series of air -duct housings [FDBZ492, FDBZ492-HR, FDBZ492-R & FDBZ492-RP] Remote alarm indicator [FDBZ492-RTL] • Robust, compatible conventional remote indicator test switch that incorporates tri -color light -emitting diode (LED) • Clear housing cover with smoke test port on cover for quick identification of detector type • Removable via four (4) captive -thumb screws (no tools required) • Includes a smoke I aerosol detector test port • Optional NEMA 4X -reinforced, stainless-steel and watertight enclosure available, Model FDBZ-WT • No tools required for cover removal, sampling and exhaust -tube installations • Trouble -event activation upon front -cover removal • Alarm LED visible from front Product Overview The Siemens— Fire Safety Model 'FDBZ'-series of air - duct -detector housings are designed for use with Cerberus PRO, FireFinder® XLS and MXL® addressable FACPs — and are operable on System 3TM and SXL® conventional systems (see: Details for Ordering for a complete list of compatible devices). Designed for installation directly to heating, ventilating and air-conditioning (HVAC) duct systems, the Model 'FDBZ'-series of duct housings complies with National Fire Protection Association Standard (NFPA) No.'s 72 and 90A, and is Underwriters' Laboratories Listed. When equipped, the air -duct detector housing will signal the presence of smoke being carried through the duct system. Air -duct detectors are not intended to be substituted for open -area detection. Notes: Most conventional time -control equipment guarantee only one (1) detector per zone when the detector's operated relay function is critical. The connection of a remote lamp and a remote relay —per detector — is allowed. Refer to the installation manual of the respective conventional FACP. CerberusTM PRO Watertight housing [FDBZ-W11 • Self-contained model available with 'on -board' power supply for conventional detectors • Expanded temperature range • Relay models available • €}UL268A Listed, @ULC -5529 Listed Notes - (cont.'d): With either the Cerberus PRO series or FireFinder. XLS series of FACPs, up to 252 -addressable detectors with relays per circuit may be used. The connection of an intelligent remote lamp (ILED) and a remote relay is allowed for each detector simultaneously. Specifications The Model 'FDBZ'-series of air -duct housings are uniquely designed to use with the photoelectric detecIor. Sensitivity of Models PE -11, PE -11C, OP121, and 8854 conventional detectors can be verified for calibration via LED visual status or a Model RSAW-11, Model RSAC-11 or FDBZ492-RTL multi- color remote lamp. A green flash indicates the detector has passed its self test. Amber indicates a Trouble condition, and red indicates an Alarm event. Sensitivity for Models FP -11, HFP-11, SFP-11, HFPO-11, SFPO-11, OP921, 00H941, 00HC941, 8710, and 8713 intelligent detectors can be verified from the multi -color LED of the respective detector, or its sensitivity reading may be printed by command from the corresponding FACP to an optional printer. 9906 Fire Safety & Security Products Model 'FDBZ' Series of Air -Duct Housings and Detectors Answers for infrastructure SIEMENS Specifications — (continued) The remote alarm indicator (Model FDBZ492-RTL) allows for manual testing via a key -switch for conventional and addressable detectors, as well as the conventional and addressable air-duct housing with relay. Model FDBZ492- RTL, which mounts remotely from the conventional and addressable air-duct housing, allows for manual relay- output control. The duct-detector remote indicator key - switch also indicates the current state of the detector. The watertight housing (Model FDBZ-WT), which allows the air-duct detector housing to be installed inside the separate NEMA 4X enclosure, is for installations for either an outdoor area or in environments where excessive moisture is prevalent. Each detector unit employs a cross-sectional sampling principle of operation. Inlet sampling tubes are available in four (4) lengths (see: Sampling Tube Selection Table). Outlet sampling tubes are one (1) common length and draw. A continuous, cross-sectional sample of air moves through the duct. Stratification or skin affect phenomenon that occurs in the duct can prevent smoke (especially in large ducts) from reaching a spot-type detector. In addition, the unique design of the sampling chamber insures uniform sensitivity in air velocities, ranging from a low of 100 fpm to as high as 4,000 fpm. Each air-duct housing comes with three (3) wiring entry ports: • Two (2) 3/4" conduit knockouts • One (1) 112" conduit opening The inlet sampling tube length is determined by the width of the air duct being protected. The inlet tube — greater than and nearest to the duct width — should be used (see: Sampling Tube Selection Table). The inlet tube can then be trimmed at the job site to the exact width of the duct. The outlet sampling tube for all ducts — irrespective of width — has a fixed length of approximately 5.5 inches 14cm.), and is supplied with the air-duct housing. Note: When the use of a remote relay is required, order Model FDBZ492-R for conventional systems; Model FDBZ492-HR for addressable systems. When required, a separate watertight enclosure (Model FDBZ-WT), which is designed to contain the air-duct housings is available. (For full details, refer to installation instructions for the respective air-duct housing.) Note: When a self-contained duct detector with power supply is required, order Model FDBZ492-RP. (For full details, refer to installation instructions part number A6V10330327.) SIEMENS Industry, Inc. Building Technologies Division Sampling Tube Selection Table Duct Width Sampling Tube (Model No.) For duct widths 6" to 1' ST -10 For duct widths 1' to 3' ST -25 For duct widths 3' to 5' (requires support) ST 50 For duct widths 5' to 10' (requires support) ST 100 Maintenance of the detector is easily accomplished via the removal of the duct -housing sampling chamber cover. The detector, which plugs into the housing, is easily removed for cleaning or replacing by a trained technician. All that is necessary for installation of the air -duct detector is the cutting of three (3) small holes for the Sampling Tube installation (template included), and the drilling of two (2) holes for mounting the air -duct housing. The unit is then easily mounted in place, and connection made to the existing wires or terminals — if optional accessories are utilized. No mechanical tools are required for removing the cover or connecting the sampling and exhaust tubes to an air -duct housing. Models ST -50 and ST -100 require support. However, Model ST -100 is shipped in two (2) 5 -ft (152 cm.) pieces with a coupling for field assembly. Technical Data Operating Temperature Ranges: Sampling Tube Pressure Range of Differences: Relative Humidity: Air Pressure / Altitude Range: Air -Duct Velocity: Dimensions: Detector Weight: +32°F (0°C) to 120°F (49°C) > 0.01 inches; < 1.2 inches of water column 0 — 95%; non -condensing No effect No limitations 100 — 4,000 ft. / min (0.51— 20m/sec) {H -x -W -x -D} • Rectangular: 14.38" -x- 5"-x-2.5" (37 cm. -x- 12.7 cm. -x- 6.36 cm.) • Square: 7.75" -x- 9" -x- 2.5" (19.7 cm. -x- 22.9 cm. -x- 6.36 cm.) 1.8 Lbs. (0.82 Kg.) CerberusTM PRO Operation Based on the monitoring results, the LED indicator flashes the following colors based on the following conditions: Flash Color Condition Flash Interval (in seconds) Green*: Normal supervisory operation. Smoke sensitivity is within rated limits. 10 Yellow: Detector is in Trouble condition, and needs either repair or replacement. 4 E Alarm condition. 1 No Flash: Detector is not powered. -- * LED can be turned OFF. Please follow the corresponding description of the panel used. Compatible FACPs Model Number Data Sheet Number Description -- 5000 MXL (system overview) -- 6300 XLS (system overview) FC901 9813 50 -point panel FC922 9815 252 -point addressable system FC924 9815 504 -point addressable system Products included with the air -duct housing: - (1) short -return (outlet) tube - (1) stopper - (2) #12 + 3/4" sheet -metal screws - (1) mounting template Note: Detector and sampling tube to be purchased separately. Minimum hardware required is: one (1) air -duct housing assembly; one (1) sampling tube and one (1) detector. SIEMENS Industry, Inc. Building Technologies Division Details for Ordering Model Number Part Number Description FDBZ492 554319 -B22 -A1 A two -wire addressable or conventional duct detector (without relays) designed for direct use on heating, ventilating and air- conditioning (HVAC) air -duct systems. When equipped, the air -duct detector housing will signal the presence of smoke being carried through the duct system. For use with the following Models: — 8710 —8713 —00H941 —0P121 — 8854 — HFPO-11 — 00HC941 — PE -11 — FP -11 — HFP-11 —PE -11C — SFP-11 — SFPO-11 FDBZ492-HR S54319 -B23 -A1 A two -wire addressable duct detector (with relays) designed for direct use to HVAC air - duct systems and works with the Remote Test Switch (FDBZ492-RTL). This part has a programmable relay base, and when equipped, the addressable air -duct detector housing will signal the presence of smoke being carried through the duct system. For use with the following Models: — 8710 — FP -11 — 8713 — HFP-11 — 00H941 — HFPO-11 — 00HC941 — OP921 — SFP-11 — SFPO-11 FDBZ492-R 554319 -B24 -A1 A two -wire conventional duct detector with relays designed for direct use on HVAC air - duct systems. This detector has a relay base, and when equipped with conventional air -duct housing, will signal the presence of smoke being carried through the duct system. For use with the following Models: — PE -11 — PE -11C — OP121 — 8854 FDBZ492-RP 554319 -B25 -A1 A four -wire conventional duct detector with relays and a built-in power supply. Housing is designed for direct use to HVAC air -duct systems. It has a relay base with a built-in power source. When equipped with conventional air -duct housing, this duct detector will signal the presence of smoke being carried through the duct system. For use with the following Models: — PE -11 — PE -11C — OP121 FDBZ492-RTL 554319-527-A1 I Device is used for manual testing via a key - switch for duct -housing Models FDBZ492-R, FDBZ492-RP and FDBZ492-HR. Device mounts remotely from the conventional and addressable air -duct housing, allowing for manual relay -output control. The duct - detector remote key -switch also indicates the current state of the detector. For use with the following Models: •FDBZ492-HR • FDBZ492-R • FDBZ492-RP FDBZ-WT S54319 -B26 -A1 An optional, separate watertight NEMA 4X enclosure (Model FDBZ-WT) that provides added watertight protection for any of the Model FDBZ492-series duct housings. The duct housing fits into the separate 4X enclosure. This part allows the air -duct detector housing to be installed in the separate enclosure, and can be used in either an outdoor area or in environments where excessive moisture is prevalent. For use with the following Models: — FDBZ492 — FDBZ492-R — FDBZ492-HR — FDBZ492-RP ST -10 500-649710 Sampling tube for Ducts 6" to 1' > ST -25 500-649711 Sampling tube for Ducts over 1' to 3' ST -50 500-649712 Sampling tube for Ducts 3" to 5' ST -100 500-649713 Sampling tube for Ducts 5'to 10' CerberusTM PRO SIEMENS CerberusTM PRO Siemens Industry, Inc. — Building Technologies Div 8 Fernwood Road • Florham Park, NJ 07932 Tel: (973) 593-2600 • Fax: (908) 547-6877 Web: www.USA.Siemens.com/Cerberus-PRO NOTICE — The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The devices described here have specific instruction sheets that cover various technical, limitation and liability information. Copies of these instruction sheets and the General Product Warning and Limitations document, which also contains important information, are provided with the product and, are available from the Manufacturer. Information contained in these documents should be consulted before specifying or using the product. For further information or assistance concerning particular problems contact the Manufacturer. Building Technologies Division SII —Fire Safety [Printed in U.S.A August 2013 — Supersedes sheet dated 6/2013 (Rev. 3) SIEMENS HFP-11 FireFinderTM Detector Fire Safety Intelligent Fire Detector for FireFinder XLS and FS -250 Control Panels ENGINEER AND ARCHITECT SPECIFICATIONS Model HFP-11 • Most Sophisticated "Detector Intelligence" available today • Multi -Criteria fire detection for the price of a photoelectric detector • FirePrintTM Technology to discriminate between deceptive phenomena and an actual fire • Easily programmed to match specific hazard profiles from the control panel • Polarity Insensitive with SureWireT""Technology • Pre -Alarm reporting based on fire profile selected • Remote sensitivity measurement capability • System logic activation based on any of three inputs from detector (smoke, heat or neural network) • Detectors are self -testing, completing diagnostics every 4 seconds • Field cleanable chamber with replaceable chamber parts available • Multi -color detector status LED • Two -wire operation • Compatible Model DPU field device programmer/tester unit • Supports software based automatic environmental compensation • Optional fully programmable relay base, audible base, and duct housing ULC Listed, CSFM, FM, NYMEAApproved Introduction The Siemens Building Technologies, Fire Safety Divi- sion HFP-11 Intelligent Fire Detector provides the life safety industry with the most highly evolved detection system available today. The HFP-11 utilizes advanced detection technology that allows the detector to distinguish non -threatening deceptive phenomena, such as cigarette smoke, from actual fire hazards, while optimizing detection for the area in which it is installed. No other detection system available today offers a higher level of protection or nuisance alarm immunity. The HFP-11 uses state-of-the-art micropro- cessor circuitry with error check, detector self -diagnos- tics and supervision programs. The HFP-11 intelligent fire detector is compatible with the Fire Safety Model DPU field device programmer/ tester unit, which is a compact, portable, menu -driven accessory for electronically programming and testing detectors, easily and reliably. The DPU eliminates the need for cumbersome, unreliable mechanical program- ming methods, such as dials or switches and reduces installation and service costs by electronically pro- gramming and testing the detector prior to installation. The HFP-11 fire detector is compatible with the Fire Finder XLS series of control panels. CATALOG NUMBER 6301 Description The HFP-11 is a plug-in, two -wire, multi -sensor detector with both photoelectric and thermal inputs and is compat- ible with Fire Finder XLS and FS -250 series of control panel systems. Each detector consists of a dust resis- tant, field -cleanable photoelectric chamber, a solid state non-mechanical thermal sensor, and microprocessor based electronics with a low -profile plastic housing.The HFP-11 utilizes state-of-the-art ASIC circuitry and surface mount technology for maximum reliability. Every HFP-11 fire detector is shipped with a protective dust cover.The HFP-11 fire detector utilizes an infrared light emitting diode (IRLED), and light sensing photodiode. Under normal conditions, light transmitted by the LED is directed away from the photodiode and scattered through the smoke chamber in a controlled pattern.The smoke chamber is designed to manage light dissipation and extraneous reflections from dust particles or other non - smoke airborne contaminants in such a way as to main- tain stable, consistent detector operation. When smoke enters the detector chamber, light emitted from the IRLED is scattered by the smoke particles and is received by the photodiode. The HFP-11 also utilizes a modern, accurate, shock - resistant thermistor to sense temperature changes. The "on -board" FirePrint technology allows the detec- tor to gather smoke and thermal data, and to analyze this information in the detector's "neural network" By comparing data received with the common characteris- tics of fires, or fire fingerprints, the HFP-11 can com- pare these "Fire Prints" to those of deceptive phe- nomena that cause other detectors to false alarm. The advanced FirePrint technology allows the HFP-11 to accurately determine a true fire hazard from a non- threatening deceptive phenomena WITHOUT needing to use alarm delaying verification and confirmation techniques, which can increase the probability of losses due to fire. The HFP-11 provides the highest level of detector intelligence available today with a detector/control panel link that allows the user to program the detector for the specific hazard profile using a simple software menu selection. Detectors are optimized by selecting one of the following eleven applications: • Office/Retail • Lobby • Computer Room • Dormitory • Healthcare • Parking Garage • Utility/Transformer Room • Hostile Environment • Precious Storage • Air Duct • Warehouse/Light Manufacturing The software does the rest; no guessing on detector sensitivities or alarm verification; the control panel programs the HFP-11 detector for the protected area without hassle and without confirmation delays. Once optimized for the hazards in the protected area, the HFP-11 provides the best detection you can buy. Should the operator or installer forget to program the detector, the HFP-11 will revert to a default setting that allows it to operate as an office environment detector. The HFP-11's FirePrint technology monitors input from both the photo chamber and the thermal sensor, evaluating this information with sophisticated math- ematical formulas, or algorithms, comparing this input to characteristics of both threatening fires and decep- tive phenomena that would "fool" any ordinary detec- tor. This technology was developed over years of research and reviewing the results of over 20 years of fire test data in one of the world's most advanced fire research centers. The results of this research are the mathematical models that form the algorithms used in FirePrint. No other fire detector has this level of intelligence or this amount of research and development supporting it's design. The microprocessor's software can identify and disregard false input caused by radio frequency (RFI) and electromagnetic (EMI) interference, and validates all trouble conditions before annunciating or reporting to the control panel. The HFP-11 detector's microprocessor uses an integral EEPROM to store the detector's address and other critical operating param- eters which include the assigned program values for alarm and trouble thresholds. Communications within the detector itself and be- tween the HFP-11 and the control panel, or with the DPU field device programmer/tester unit, are super- vised and safe -guarded against disruption by reliable, microprocessor based error checking routines. Addi- tionally, the micro -processor supervises all EEPROM memory locations and provides a high degree of EEPROM failure fault tolerance. The HFP-11 determines its operating status to be normal, in alarm, or in trouble depending on the difference between the alarm threshold values stored in the detector's memory and the detector's latest analog measurement. The detector then communicates changes in its status to the control panel. In addition, the FireFinder XLS control panel will sample the value of the HFP-11's analog signal over a period of time in order to determine if those values indicate excessive buildup in the photo chamber; if so, the FireFinderXLS control panel will indicate that the particular detector requires maintenance. The HFP-11 is listed as a self -testing device.The HFP-11's visible light emitting diode (LED) flashes green every 4 seconds to indicate it is communicating with the control panel and that it has passed its internal self -test. Should the detector sense a fault or failure within its systems, the LED will flash amber and the detector will transmit that information to the control panel. A quick visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed information is required, a printed report can be provided from the Fire Finder XLS panel indicating the status and settings assigned to each individual detector. When the HFP-11 moves to the alarm mode, it will flash red and to continue flashing until the system is reset at the control panel. At that same time, any user defined system alarm functions programmed into the system are activated. Detector sensitivity, calibration, and identification are dynamically supervised by the control panel. Detector sensitivity and pre -alarm levels are a function of the application chosen at the control panel and are controlled by the panel. If an alternate, non-FirePrint mode is selected, then the sensitivity can be changed from the control panel. The DPU Device Program/Test Unit accessory is used to program and verify the detector's address. The technician selects the accessory's program mode to enter the desired address. The DPU automatically sets and verifies the address and tests the detector. The DPU operates on AC power or rechargeable batteries, providing flexibility and convenience in programming and testing equipment almost anywhere. When in the test mode, the DPU will perform a series of diagnostic tests without altering the address or other stored data, allowing technicians to determine if the detector is operating properly. The HFP-11 fire detector may be installed on the same initiating circuit with HMS series manual stations, HTRI series interfaces, HCP output control devices, or HZM series of addressable, conventional zone modules. All HFP-11 detectors can be cleaned in the field, when required, by simply removing the detector cover and unsnapping the photo chamber. There is also the option of cleaning the interior of the detector with a clean, soft cloth or brush, or replacing the labyrinth and bug screen included in the detector maintenance kit, model DMK-11. The HFP-11 uses the low -profile surface mounting base, model DB -11. This base mounts on a 4 -inch octagon, square, or a single gang electrical box. The base utilizes screw clamp contacts for electrical connections and self -wiping contacts for increased reliability. The base can be used with the optional LK -11 detector locking kit which contains 50 detector locks and an installation tool, to prevent unauthorized removal of the detector head. The DB -11 base has integral decorative plugs to cover the outer mounting screw holes. All HFP-11 detectors are approved for operation within the UL specified temperature range of 32 to 100 degrees F (0 to 38 degrees C). Application Data Installation of the HFP-11 series of fire detectors requires a two -wire circuit. In many retrofit cases, existing wiring may be used. "T -tapping" is permitted only for Style 4 (Class B) wiring. The HFP-11 is polarity insensitive. This feature can greatly reduce installation an debugging time. HFP-11 fire detectors can be applied within the maximum 30 foot center spacing (900 sq. ft. areas) as referenced in NFPA 72. This applications guideline is based on ideal conditions, specifically, smooth ceiling surfaces, minimal air movement, and no physical obstructions between potential fire sources and the detector. Do not mount detectors in close proximity to ventilation or heating and air conditioning outlets. Exposed joints or beamed ceilings may also affect safe spacing limitations for detectors. Should questions arise regarding detector placement, observe NFPA 72 guidelines. Good fire protection system engineering and common sense dictate how and when fire detectors are installed and used. Contact your local Fire Safety distributor or sales office whenever you need assistance applying FirePrint in unusual applications. Be sure to follow NFPA guidelines and UL/ULC approved installation instructions, which are included with every Fire Safety detector, and local codes as for all fire protection equipment. Dimensions T 2 3" Overall Height 1 6" Diameter Base Technical Specifications Operating Temperature: +32°F (0°C) to 100°F (38°C) per UL 268/268A Humidity: Maximum spacing: 0-93% Relative Humidity Non -Condensing 30 foot centers (900 sq. ft.) per NFPA 72 Chapter 5 and CAN/ULC-S524 Mads( Description Put Nrrmber NFIx11 Acldre sakde FirePrim Fire Delee:ar 500 D D6 -1t Detach ManmingBase Int Sens 11 500-091151 I 013,11E. Dcicelrx Bate (seyaill 5064091151 E AD"1 FP Ar Duct Housing ler Series 11 5064M% AD -HP An Duct Housing YoRelay int H -Series r m 1 ent Deter or 506-33230 DB"HA Pe* Bose !or 11 -Sews Imnfligen Detectors 500.0.33120 v ADB/1.11 Audible base 5064133710 RL -MC Remote Ices¢ alarm indtcamt- 4' octagon bwl mount 506-1133230 RL -HW Remote Iredi warm indicator single gang bur mourn 5: 104132310 LK -11 Base Locking Et for Series 11 detectors 50D-6953SO DMK-11 Series 11 Maim KrI 'replacement labyrinth and bug bug screw) 500-BBS3311 le Gide Men HFP-TIC Addressable FmePrir:t Fire Detector 1LFL0 506.0951120 DB -11C Detector Mourning Base for Seriss1BULC1 , MD-09TSW AD-11PC AiDrctHousing lULCi 500-091 DB -HRC Relay Duette Series 11 Intelligent Detectors (ULC] SOD -03320 ADElt1.11C Audible Base for Sens 11 Int :lig+ent Detecmr WW1 506.03321tE NOTICE: The use of other than Fire Safety detectors and bases with Fire Safety equipment will be considered a misapplication of Fire Safety equipment and as such void all warranties either expressed or implied with regard to loss, damage, liabilities and/or service problems. Siemens Building Technologies Fire Safety Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 10/05 Brampton, Ontario Tel: (973) 593-2600 5M Canada L6T 5E4 FAX: (973) 593-6670 SFS -IG Tel: (905) 799-9937 October2005 Website: www.sbt.siemens.com/fis Printed in U.S.A. FAX: (905) 799-9858 Supersedes sheet dated 7/03 SIEMENS TSM -1 Duct Detector Test Switch ENGINEER AND ARCHITECT SPECIFICATIONS • T-45 Key Operated • LED Indicates Detector in Alarm • Mounts in Single Gang Box • Compatible with All Siemens Building Technologies, Fire Safety Division Intelligent Duct Detectors • ®UL Listed Fire Safety Description The TSM -1, Test Switch Module is a key activated device that will functionally test a detector. The module is compatible with Siemens Fire Safety intelligent fire, smoke and duct detectors used on MXL, MXLV and MXL-IQ systems. The TSM -1 includes a red LED that illuminates when the corresponding duct detector is in alarm. The switch operates in conjunction with a TRI -R Interface Module with relay. Either that relay or the relay in the duct detector can be used for control of building equipment such as HVAC fans and elevators. The TSM -1 mounts in a single gang electrical box and includes a red cover plate. When the switch is operated a signal is transmitted to the appropriate detector forcing it to alarm. That alarm will activate all functions programmed to follow that detector. The TSM -1 therefore provides a true functional test of the actions associated with duct detectors on MXL systems as require by many jurisdictions. Underwriters' Laboratories, Inc has listed the TSM -1 as compatible with MXL intelligent detectors. Ordering Information Model Description TSM -1 Detector Test Switch 1 1500-696353 Part Number Refer to Installation Instructions, P/N 315-098285 CATALOG NUMBER 6196 TSM -1 Interface to MXL System TSM -1 LED operated by theTRI-R relay contacts. From MXL + ALD Loop End of Line Device for TRI -R 3.6K, 1/4W, P/N 140-820185 0 000 Switch + – Input LED TSM -1 01 02 0 3 04 Earth Ground"' 5 TRI -R 8 l To Air Duct } Detector or next JJJ device on loop } 24 VDC From MMB -2, TB5 Terminals 9-12 or PSR -1, TB3 Terminals 3-6 or UL Listed Power Supply Notes: 1. For use only with Air Ducts with an incorporated relay. 2. Refer to the TRI Installation Instructions, P/N 315-096242, for specific interface module wiring requirements. 3. Refer to the AD -11 P, AD-11XPR Installation Instructions, P/N 315-095659, or the AD-31/-3ILP Installation Instructions, P/N 315-093234, for specific duct detector wiring requirements, as applicable. TSM -1 Interface to MXL System TSM -1 LED operated by the Air Duct Detector. From MXL + ALD Loop End of Line Device for TRI -R 3.6K, 1/4W, P/N 140-820185 1To Air Duct Detector or next device on loop Switch Input � + – LED TSM -1 01 02 03 04 Earth Ground4-0 5 TRI -R To Fan Shutdown Control To Air Duct Detector 10. + (See Detector installation Instruction for Remote Alarm Indicator 10. Connection) Notes: 1. For use only with Air Ducts without an incorporated relay. 2. Refer to the TRI Installation Instructions, P/N 315-096242, for specific interface module wiring requirements. 3 Refer to the AD -11P Installation Instructions, P/N 315-095659, or the AD-31/-3ILP Installation Instructions, P/N 315-093234, for specific duct detector wiring requirements, as applicable. Mounting Diagram Caution: The TSM -1 switch module does not perform all of the required smoke detector test as specified in NFPA Standard 72. Please refer to the instructions that accompany the detector for the complete test requirements. Single Ging Mounting Bon Nm SuPPkd? TSM -1 Assembly 0 Siemens Building Technologies Fire Safety Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard Florham Park, NJ 07932 7/03 Brampton, Ontario Tel: (973) 593-2600 5M Canada L6T 5E4 FAX: (973) 593-6670 SFS -IG Tel: (905) 799-9937 Website: www.sbt.siemens.com/fis Printed in U.S.A. FAX: (905) 799-9858 July 2003 Supersedes sheet dated 2/02 SIEMENS HTRI Series FireFinder XLS and FS -250 Intelligent Initiating Devices Interface Modules Fire Safety ENGINEER AND ARCHITECT SPECIFICATIONS Intelligent Interface Modules for FireFinder XLS and FS -250 Series Fire Alarm Control Panels HTRI-S, HTRI-D, HTRI-R • Interfaces and Supervises Normally Open or Normally Closed Contacts • Integral SPDT Relay (up to 4 amps) on HTRI-R Model • Dual Input on HTRI-D Model using a single address • Polarity Insensitive with SureWire'T' Technology • Multi -color L.E.D. indicates status (green, amber, red) • Easy front access to programming port and wiring terminals • Mounts 4 inch square 2'/a deep box, or double gang box • Dynamic Supervision • Comes with 5x5 inch faceplate • Two wire operation • DPU Device Program/Test Unit programs and Verifies Device's Address and Tests Devices functionality • Electronic Address Programming is Easy and Dependable • ULC Listed U� CFSM, FM, NYMEAApproved Introduction The HTRI Series Intelligent interface modules are de- signed to provide the means of interfacing direct shorting devices to the FireFinder XLS and FS -250 Fire Alarm Control Panel loop circuit. The HTRI Series Intelligent interface modules provide the market's most advanced method of address programming and supervision, combined with sophisticated control panel communication. Each HTRI Series interface module incorporates a microcomputer chip. The HTRI Series microcomputer chip technology and its sophisticated bi-directional communication capabilities with the control panel, achieve the state of an "Intelligence Device." Description The HTRI Series intelligent interface modules are available in three models. The HTRI-S and HTRI-R are designed to monitor a normally open or closed dry contact. The interface module reports the contact's status to the control panel. The HTRI-S model can only monitor and report the status of the contact, while the HTRI-R incorporates an addressable Form C relay. The HTRI-R relay and contact device input are controlled at the same address. For the control panel system, the relay and input contact can be controlled as a separate function. The relay is typically used where control or shunting of external equipment is required. The HTRI-D is a dual input module and is designed to supervise and monitor two sets of dry contacts. The Dual Input Module only requires one address but re- sponds independently to each input. The HTRI-D is ideal for monitoring a water flow switch and its respective valve tamper switch. The HTRI has a multi -color Light Emitting Diode that flashes green when operating normally, amber if unit is in trouble condition, and red to indicate a change of state. The HTRI-D flashes twice, once for each ad- dress, the HTRI-R red L.E.D. indicates a change of state in the relay. CATALOG NUMBER 6304 The device's microcomputer chip has the capacity of storing, in memory, identification information as well as important operating status information. Siemens BuildingTechnologies, Inc., Fire Safety Division innovative technology allows all HTRI Series intelligent interface modules to be programmed by using the DPU Device Programming/Test Unit. The DPU is a compact, portable, menu driven accessory that makes program- ming and testing an interface device faster, easier and more dependable than previous methods. The DPU eliminates the need for mechanical addressing mecha- nisms, such as program jumpers, DIP switches or rotary dials, because the DPU electronically sets the HTRI interface's address into the interface's microcomputer chip nonvolatile memory. Vibration, corrosion and other conditions that deteriorate mechanical addressing mecha- nisms are no longer a cause for concern. The HTRI Series is fitted with screw terminals for connection to an addressable circuit. The HTRI Series is fully compatible on the same FireFinderXLS and FS -250 circuits with all intelligent H Series detectors, HMS Series addressable manual stations or any other addressable intelligent modules, such as the HZM or HCP. All HTRI Series intelligent interface modules are UL listed. Environmental operating conditions for all HTRI Series modules are 32°F (°C) to 120°F (49°C) with a relative humidity of not greater than 93% non-condensating. Ordering Information Model Description Shipping Wt. Lb. Kg. Part Number HTRI-S Single Input 7 flz. 2 500-033370 HTRI-R Single Input w/Relay 7 az. 2 500-033300 HTRI-D Nal input 7 az. 2 500-033360 NOTICE: The use of other than Fire Safety detectors and bases with Fire Safety equipment will be considered a misapplication of Fire Safety equipment and as such void all warranties either expressed or implied with regard to loss, damage, liabilities and/or service problems. Siemens Building Technologies Fire Safety Mounting Data Addressable Interface Model HTRI-S, HTRI-D, HTRI-R mounts directly into a 4 inch square 2 1/a deep box or a double gang box (user supplied). A 5 inch square off-white faceplate is included with each HTRI. MOUNTING SLOTS FOR 4 INCH SWITCH BOX MOUNTING SLOTS FOR DOUBLEGANG SWITCH BOX Figure A Mounting the HTRI-S/--D/-R Electrical Ratings Current Draw (Active or Standby): 1 mA HTRI-R Relay Ratings Resistive: 4A, 125 VAC 4A, 30 VDC Inductive: 3.5A, 120 VAC (0.6P.F.) 3.0A, 30VDC (0.6P.F.) 2.0A, 120 VAC (0.4P.F.) 2.OA, 120 VAC (0.35P.F.) 2.0A, 30 VDC (0.35PE) Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (973) 593-6670 Website: www.sbt.siemens.com/fis 12/04 5M SFS -IG Printed in U.S.A. Fire Safety 2 Kenview Boulevard Brampton, Ontario Canada L6T 5E4 Tel: (905) 799-9937 FAX: (905) 799-9858 HTRI-S/-D/-R MODULE MOUNTING HOLES FOR SWFTCHPLATE December 2004 Supersedes sheet dated 1/03 SIEMENS Z Strobes, Horns, Horn/Strobes ENGINEER AND ARCHITECT SPECIFICATIONS • UL listed. ULC, CSFM, and FM pending. • ADA/NFPA compliant • EZ Mount design, with separate base plate, provides ability to pre -wire the base and test the circuit wiring before the walls are covered • The base plate is protected by a disposable cover and the appliances can quickly snap onto the base after the walls are painted. • EZ Mount Universal Mounting Plate (ZBB) — uses single plate for ceiling and wall mount installations • Wall Mount models feature field selectable candela settings of 15/301751110cd and 135/185cd • Ceiling Mount models feature field selectable candela settings of 15/30/75/95cd and 115/177cd • Strobes can be synchronized using the Siemens DSC sync modules, FS -250 panel, XLS panel, or PAD -3 power supply with built-in sync protocol • "Special Applications" listed with Siemens panels • Strobes produce 1 flash per second Selectable Continuous Horn or Temporal (Code -3) Tones with selectable 90 or 95 dBA setting (ZH model) Fire Safety Series ZH Series ZR ZR AND ZH Mounting Description The Siemens Series Z notification appliances feature an easy snap on base that is designed to simplify the instal- lation and testing of horns, strobes, and horn/strobes. The separate Series Z snap on base can be pre -wired so circuit wiring can be fully tested before the appliance is installed and before the walls are covered. Once all sur- rounding work is complete, the appliance can be simply installed by snapping it on the base. Shorting contacts in the base, which provide continuity for circuit testing, are permanently opened when the appliance is installed so any subsequent removal of the appliance will indicate a trouble condition on that circuit at the control panel when circuit supervision is enabled. The same base is used for all Series Z horns, strobes and horn/strobes to provide consistent installation and easy replacement of appli- ances if required. A locking screw is also included for the appliance to provide extra secure installation. The Siemens Series Z appliances incorporate the same dependable circuitry and high efficiency optics that are used in Siemens ST strobes, NS horn/strobes and NH horns and have the same high performance ratings. The Series Z appliances are "Special Applications" listed with Siemens panels. Engineering Specifications General Audible/visual notification appliances shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. These appliances shall be listed under UL Standard 1971, (Standard for Safety Signaling Devices for Hearing Impaired) and UL Standard 464 (Fire Protec- tive Signaling). The appliances shall use a universal backplate that shall allow mounting to a single -gang, double -gang, 4 -inch square, 4" octal, or a 3-1/2" octal backbox. Two wire appliance wiring shall be capable of directly connecting to the mounting back plate. Conti- nuity checking of the entire NAC circuit prior to attach- ing any audible/visual notification appliances shall be allowed. A dust cover shall fit and protect the mounting plate. The dust cover shall be easily removed when the appliance is installed over the backplate. Removal of an appliance shall result in a trouble condition by the Fire Alarm Control Panel (FACP). Strobes Strobe appliances shall produce a minimum flash rate of 60 flashes per minute (1 flash per second) over the Regulated Input Voltage Range and shall incorporate a CATALOG SHEET2584 Xenon flashtube enclosed in a rugged Lexan® Tens. The strobes shall be available with two or four field select- able settings in one unit and shall be rated, per UL 1971, for up to 185 cd for wall mounting and 177 cd for ceiling mounting. The strobes shall operate over an extended temperature range of 32°F to 120°F (0°C to 49°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Audibles and Audible/Strobe Combinations Horns and horn/strobes shall be listed for Indoor use un- der UL Standard 464. The horns shall be able to produce a continuous output or a temporal code -3 output that can be synchronized. The homs shall have at least 2 sound level settings of 90 and 95 dBA. Synchronization Modules When synchronization of strobes or temporal Code -3 au- dibles is required, the appliances shall be synchronized using the Siemens DSC sync modules, FS -250 panels, XLS panels, or PAD -3 power suppies with built-in sync protocol. The strobes shall not drift out of synchroniza- tion at any time during operation. Audibles and strobes shall be able to be synchronized on a 2 -wire circuit with the capability to silence the audible if required. If the sync module or power supply fails to operate (i.e., con- tacts remain closed), the strobes shall revert to a non - synchronized flash rate. All notification appliances shall be listed for "Special Applications". • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Input Voltage Range". • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series ZH Strobe products are listed under UL Stan- dards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). • Series ZH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). Technical Information For complete technical information, please consult the relevant installation sheets as well as the Siemens Compatibility Guide. Ordering Information / Mounting Requirements / Approvals Model Number Order Code Mounting Options# Agency Approvals UL ULC CSFM FM ZH-MC-R 500-636161 B, D, E, F X # # # ZH-MC-W 500-636162 B, D, E, F X # # # ZH-HMC-R 500-636163 B, D, E, F X # # # ZH-HMC-W 500-636164 B, D, E, F X # # # ZH-R 500-636159 B, D, E, F X # # # ZH-W 500-636160 B, D, E, F X # # # ZH-MC-CR 500-636165 B, D, E, F X # # # ZH-MC-CW 500-636166 B, D, E, F X # # # ZH-HMC-CR 500-636167 B, D, E, F X # # # ZH-HMC-CW 500-636168 B, D, E, F X # # # ZR -MC -R 500-636169 B, D, E, F X # # # ZR -MC -W 500-636170 B, D, E, F X # # # ZR -HMC -R 500-636171 B, D, E, F X # # # ZR -HMC -W 500-636172 B, D, E, F X # # # ZR -MC -CW 500-636174 B, D, E, F X # # # ZR -MC -CR 500-636173 B, D, E, F X # # # ZR -HMC -CR 500-636175 B, D, E, F X # # # ZRS-HMC-CW 500-636176 B, D, E, F X # # # ZBB-R 500-636193 Accessory - Includes base, dust cover, mounting screws and installation sheet ZBB-W 500-636194 Accessory - Includes base, dust cover, mounting screws and installation sheet X = listed/approved # = pending = Refer to Data Sheet #2585 for mounting options. WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Siemens Building Technologies Fire Safety Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (973) 593-6670 Website: www.sbt.siemens.comlfis 7/07 5M SFS -IG Printed in U.S.A. Fire Safety 2 Kenview Boulevard Brampton, Ontario Canada L6T 5E4 Tel: (905) 799-9937 FAX: (905) 799-9858 July 2007 New Issue RETAINER STRAP WHERE REWIRED IN SEISNIC AREAS TPP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL. JOIST/TRUSS HANGER DETAIL NTS Design per NFPA 13, Ordinary Hazard All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart 3— Add Reliable Model G4 standard response 165° white concealed pendents 1/2 x 1/2 0 A 5 — Add Reliable Model Fl standard response 155° white semi -recessed pendents 1/2 x 1/2 akk8 — Relocate Reliable Model F1 standard response 155° white semi -recessed pendents 1/2 x 1/2 o E — Existing upright no change 16 — Total 0 0 Without Comments As Noted in Red Per The Attached Letter hese plans have been reviewed by The Tukwila Ere fevention Bureau for conformance. with current City :YF,ndards. Acceptance is subject to errors and missions which do not authorize violations of adopted ;Tandards and ordinances. The responsibility for the ;equacy of design rests totally with the designer. .editions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. • Final acceptance Is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: 4' -4? -'1 By: sll Space 316 TUKWIL1 FIRE DEP a R y 1E Please ca'1f)G-5t'5-^ ln7 &id Jive tNs Pe"mirit No. //-S- /--?- ard exact E.: i LS or s. c.Uv'ti ,..L ..G `ieV� f1 fJ;` f-�d�tG =a t'' p e ova1.. NOME Weld stamps must be inspected before pipe is hung. Do not paint piping ;1� 4oi to h' /%1 r.,; •atiC test CRc.WN.. FIRE PROTECTION INC©RPORA TED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7889 owr‘s CASk boct- (;--4fers Southcenter Mall Tukwila, INA - --- PAID MAY 31 2011 TUKWILA FIRE 4. 1 DRAWN: CC)" SCALE: ' 1 /41 O O ---a--- ---- IZ -------a------ o .1.00 OM ---dal, ---- ----a--- --- --- --_�----2-` Et ,i, Ro Oy_ 0 179Vrf fir!, 0c QG 1 1 f0 Q11 V I E>1 tV v� ® 0 (1' .M• WWI MOO 711.E. ABM InIMIO MN, MI= 077 MEP ,MI• MON MII1M MOM ISM 71•MID MIND 4/M ,.../7 IMP MEM ENO 41.27 IIMIR MI= .NIM MI, IMO i O 0 O Design per NFPA 13, Ordinary Hazard All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart 3— Add Reliable Model G4 standard response 165° white concealed pendents 1/2 x 1/2 0 A 5 — Add Reliable Model Fl standard response 155° white semi -recessed pendents 1/2 x 1/2 akk8 — Relocate Reliable Model F1 standard response 155° white semi -recessed pendents 1/2 x 1/2 o E — Existing upright no change 16 — Total 0 0 Without Comments As Noted in Red Per The Attached Letter hese plans have been reviewed by The Tukwila Ere fevention Bureau for conformance. with current City :YF,ndards. Acceptance is subject to errors and missions which do not authorize violations of adopted ;Tandards and ordinances. The responsibility for the ;equacy of design rests totally with the designer. .editions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. • Final acceptance Is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: 4' -4? -'1 By: sll Space 316 TUKWIL1 FIRE DEP a R y 1E Please ca'1f)G-5t'5-^ ln7 &id Jive tNs Pe"mirit No. //-S- /--?- ard exact E.: i LS or s. c.Uv'ti ,..L ..G `ieV� f1 fJ;` f-�d�tG =a t'' p e ova1.. NOME Weld stamps must be inspected before pipe is hung. Do not paint piping ;1� 4oi to h' /%1 r.,; •atiC test CRc.WN.. FIRE PROTECTION INC©RPORA TED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7889 owr‘s CASk boct- (;--4fers Southcenter Mall Tukwila, INA - --- PAID MAY 31 2011 TUKWILA FIRE 4. 1 DRAWN: CC)" SCALE: ' 1 /41 DO LE NEAST OUTFI FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUM3ER SHEET TITLE FA -01 SYSTEM INFORVATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEIv CALCULATIONS A\D SINGLE LINE DIAGRAM FA -04 FIRE ALARM SYSTEM PLA\ SHEET INDEX Weltl f) t �'.r'ITlmefl k, Pr ;5;'t hese !R;IAns r yen ior� j4 Ll id ;ftpr : - ndrAs; 9%l tt 1y.,9f CJ `y1f1; {'.,51 .tarldPards PO. Prdirg!' 4N11:14gY gf4g.515n r' . Addi gt?s, del±rtcf f • .'?,;:sons to tI se drawings after this date will yGtd m..- tance and will require a resut#rritgl gf for suirequent approval. Final aeeeptence i :3, ;'pct to ii:;Id test and Inspection by The Tukwlle firPr•wvenciofi Bureau, Date: (' By: .r c FJre ,Ct... t City ,:,!Moor of adopted r � ;'f ;y: n5ibi;:r; far the d-esigner. TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. II -F -1 (4(0 and exact address for shut- down hutdown or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. DU LE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPUFPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE AOU-NTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 1 2 2 3 3 3 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ®DUCT DETECTOR D AD2-P W/ SIEMENS HFP-1 1 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HTR -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD Di FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N /A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND \ NORDSTROM 3 LEVELS i I !/ 171,275sf Is'CIY� m &P oEs. 250,407sf 00,01* COLO 4tG+ s DOWNEAST OUTFITTERS (1010) �k=r: ass 0,011, 1007 100.0 7000 R:P PIaG?'! .10.LIKE CHOLE CU^,AL ONG CN.:TY UJ!U!Y EO UEK_. „ LERS xd EPGTlG JCPenney 3 LEKLS 276,468sf 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS 1 DATE 0 N 0 �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 07/01/11 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER: 55278 } SHEET � o FA -01 J � THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6012 �1 DEDICATED EIER(ENCY 111 NOTE FCR ;mom SPECIF1CAnc 1S SEE PRODUCT DOCUIENTA11 1. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 301EIC m NEXT SALE � DEVICE STDP W LAST AST DD+EVICE - FTtDN XLS coma. PANEL (+ OR PREVIOUS ADDRESSABLE DEVICE 0 0 ROUND _J O O HTRI-R 0 0 o 0 NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) rjJ- N LL 0000 a 0 PAD -3 00 ° INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 3.6k EOL (-) (+) SPARE SPARE SPARE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) TSM -1 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTEDPAIRW1TH SHIELD #18 FPLIFPL.R RED (JACKET) q;ONTACT RATINGS 4.0A 0 125VAC 4.OA 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 GROUND (+) TO NEXT DEVICE OR (-) o 0 +''i HTRI-R 0 0 STOP IF LAST DEVICE (-) DRY CONTACTS TO VAV —> FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY + u HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER T1N TEMPERA RE: +32' F 0' C TO 100' F 38 C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —` FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW r DATA IN ( ) >— jl DATA IN (+) > TO NEXT ADDRESSABLE DEVICE (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX '6.1*.�.`;�: `'tee oMI: �4i:: �MMA �s.�f `:.: �':��f `:.: �':.,`•e I S��•e° :rs% A, JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT TO NEXT DEVICE CADDY BAR cEij SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS Lu 07/01/11 I— (f) W cf) cc z Wz o° r�<§ L— a fr z O Wiz( O W U= T2~� W Qog Z W CC T T LL t o CIE o J 0 EL— �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 07/01 /1 1 BACKROUND PLAN PROVIDED BY: .JOB NUMBER: 55278 } SHEET FA -02 C Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0,0022 0.0022 0.0023 0.002 AD2-P 2 0.0635 0.0635 0.064 0.128 HTR -R 3 0.009600 0.0096 0.021 0.063 0.0731 Amps 0.191 Amps NE' :xtender ad;cakLIato:n Current Lo d. Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 Z1 -1 -MC -CW ©15CD 0.0875 ZH-MC-CW ©30CD ZH-MC-CW. @75CD ZH-MC-CW @95CD 1 0.131 0.222 2 0.292 0.584 al -HMC -CW ©115CD 0.371 ZR -MC -CW ©15CD 3 0.069 0.207 ZR C -W ©15CD 1 0.064 0.064 0.03 Amps 0.885 Amps Standby Current Load: 0.03 Amps For 24 Hours 0.720 Amp -hours Alarm Current Load: 0.885 Amps For 5 Minutes= 0.074 Amp -hours 25% Derating= 0.993 Amp -hours Total System Current Load: 0.993 Amp -hours Etattetsi: t to"'' " rs TO NEAREST EXISTING D I HTR -R D Notification Appliance Circuit Detail PROJECT: iDOWNEAST OUTFITTERS T - ---- ------r---- ---------` Panel: PAD -3 POWER SUPPLY I iWire Resistance 2.58 Date:1July 12, 2011 CURRENT TOTAL= 986.00 0 -1 -MC -CW ©15CD 1 87! Zil-MC-CW ©30CD 131 131 Z1 -1 -MC -CW ©75CD 2221 01 2 7.1i -MC -CW ©95CD 292 . 584 . . , oiscD 3711 o I ZR-MC-cw @15CD 69, 207 1ZR-MC-W ©15CD 64' 641 DEVICES= 7 TOTAL mA=1, 9861 14 j 173 Total Wire Resistance ( R ) Total DeviceLoad, Amps (I) iVoltage Drop ( E ) EOL Voltage 23.12 986 1( WL * 2)* (R/ft) 089 (Total Cct Load) 0.89 !(E= I * R) 1 0.88 24 - E) 23.12 SYSTEM CALCULATIONS D S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 15cd 30cd 15cd 15cd 15cd 95cd 95cd AHU-1 D rA D,21—c-D DATA LOOP TO NEAREST EXISTING STROBE CIRCUIT 2C BPS 120VAC, DEDICATED (BY OTHERS) HTR -R AHU-2 D,2I TSM r-ta D HTR -R TSM EOL Si FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110VAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG 1 DESCRIPTION SHOP DRAWINGS DATE 07/01/11 2 <<<l< CC Z (c2) 1— 0 <a) — 1-1— cDzcc 0 < w E- oD w _ z 1— ow C,,i CD 2 15 < 5 0 LU (i) < z w cc EE 00 cc 0 0 w —J —J C/) z 0 0 0 Li! C/) ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:07/01/11 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved \.013 NUMBER: 55278 SHEET FA -03 REFLECTED CEILING PLAN —1HTR-R TO NEAREST 0 EXISTING DATA LOOP ) 0 TO NEAREST 2 EXISTING STROBE CIRCUIT 2C V) to S1-1 15cd STOCK S1-2 30cd S1-3 I 15cd l 1 1' TOILET RM. AHU-1 IHTR-R1 ITSMI S1-6 95cd s CHANGE ROOM (-YF.) I\ S17 I\� 15c Sj= / 1 5c D SALES AHJ-2 COUNTER TOP TO COMPLY YVITH ANSI 117.1;'104.3,'104.3.2 S1-7 95cd EOL S1 • FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110VAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE O t. 0 o as<aa E n , S1-1 \ 15cd \`\1_� \ V- 7 V V.--- v __/ V n n --v--V---v --v---V---v---V---77--- `/ -- ----v , i 1 ^ /^ o d .� I I v , 51-2 I { S1-6EOL 95cd �1 S1 / 30cd I I 95cd _ (' 1 I I n � L S1-3 i 1 —� { I 15cd \ > 0 0 S1-5 , S1-4 15cd 15cd 0 , REFLECTED CEILING PLAN —1HTR-R TO NEAREST 0 EXISTING DATA LOOP ) 0 TO NEAREST 2 EXISTING STROBE CIRCUIT 2C V) to S1-1 15cd STOCK S1-2 30cd S1-3 I 15cd l 1 1' TOILET RM. AHU-1 IHTR-R1 ITSMI S1-6 95cd s CHANGE ROOM (-YF.) I\ S17 I\� 15c Sj= / 1 5c D SALES AHJ-2 COUNTER TOP TO COMPLY YVITH ANSI 117.1;'104.3,'104.3.2 S1-7 95cd EOL S1 • FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110VAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE O t. 0 o as<aa 4-CALE: 1 /4"=1 '0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 07/01 /1 1 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 55278 _} SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 0. -.?,,f;?,,JA1,•-•:::,..y'-41.- 0.,.,,;-,;•1'....•1: :i -.4:. p--......,i•i,- ,..4-,..-..v;•,.0.-....,..: ,i ..:-..;,...5: ,..:-.•-•;....1 -, -4..,47.-=', 4 -,•,..,,,,..,,. r.5,11'4k1.! 4, ' 4( • '''• 4 Y.'4••..,`• --:;141:, .1' .. . .`; Z„'„„ 44.4,;',•,•.;„, i ,....?,,,,....',`,..(;„ 4:.;::-.. ,f',...,,,-;---„', , T1.4.4.,.4.1'1,14 ,.• ,-,'„ t,,:iit,.•.`..,'.....).•,!.. ..-',.."..,-.2:,.,:-;;.-f.i'.. •',.,--- ',:..7.:1,..;;-••:.* — ,,.. •-•,, -_. 01 17)0dir '....,••';'.frl.:=7v':',4•1 .--,..'-.-j.,..--,-.`"-s.:-:;,---"x "....' .. -V,,.;.:'-',.....,.•. . .• —' ' ?:4; -1: ,-,'„ t,,:iit,.•.`..,'.....).•,!.. ..-',.."..,-.2:,.,:-;;.-f.i'.. ' :4-,V.,..j•';,,,',F•.:;-..•.-.., -i2:',:;,•;..,„.„-,,,..!!,;:-,1 ,, •1 440 •4'.'"': • . •*; .1.* • . • litaliElbeigiblilitill1111111111111111111 . • • :-,:',.,4:.'4••• ''.i ,,. ;,,,,, t:.44.- .. -V,,.;.:'-',.....,.•. . .• —' ' ?:4; -1: '1,,i1,44:41•:1,1:44 0411,45: 4.-4:4 tt .,,„...1.,-4, ,.'',',!;4';,4-•,4,4,4 •,4•44.t':1'111:1.1.;', 4•',•1.: 4 -,•• ,,,, ; 4 I 4.4.:1;:* ',44,4, ..'• , -,....:1--.,,, - •er't:7,4:giC•A`..3:.'. : 1 4•4`...1i,15.:•."-;44 11.';'..-1 ' ,, 41'.r4 '4. 'ff'. A ',,,,,..?..Z,'444•: I. -'.1,4"4-•,,,';.4,--.,,e-. `-, .4')..',,,-,..."•',4S,7; :'.3 ',..s,,,,,,,,,...-'1-,;;;;,' :. .:••,.."% ,,,,- ..'"::',..',',-, . ' „,,,•,,...T.-„"..,-•.,,, .. ii'Ve...'`..•"..:-... ..-.7.tli".i.?-4:.7.,:" it,-„,..= ..:04•.e,':.',,,,..T.X.,,, i.,,t-t.,11-...0.1.',V,- -,,,.; ,A... --;:...4,...•N,.•..-. ,•re";,,t,iii..•„,.' s:',,,,:.,4 '-'4,:,..'-:'1.Z'f,::',,4k7:1 :81-1•'-',ft,.'.`t, '..,1, ,..r..i'. 1,•;,..e,i '14 ••4 A., , i'. — •,. -;;',.•-.„,t,',1; ,',....c;" -ii),•.,,,,:. Kt'.,'"P',1;•;'• ,:. i•/..•-.`,2,4..i,- ;kr:k1,''.;,:;'-f • ; .. • . • . . .• • • • • I • • Design per NFPA 13, Ordinary Hazard Group 2 - Retail All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart 0 — 3 \V\o\ 5(.015 QR Ve(•%,,CAN- )( o 11 — Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 o 8 — Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 FlexHead Sprinkler Drop Corrugated stainless steel hose with stairitess steel bral avaiThble In 2', 3,4',5' & 6 legnths • • • . • Multi -Port Brac.ket • 1111€ • . . • •: • • • • I 1111411111.1.11.1111.111.113LExtfeAn I RED • • Elexhead omniercial Ceiling Unit • , • T -Bar 'Ceiling Installation. • Model #2024,2036,2048,060,2672 • • • . • • • • • Adjustable Hub • . . " • CI Withatit Comments 0 As Noce° n Re Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bure..7,u ,-..:-.):,formance with current City standards. Acr;'•:-;-, :•: 5dolect to errors and omissions whicn c;.J •Tit!cf!i)1!?..: o(datirMS of adopted st-andaros and bri::,1; •. •,• The c.-.1,,pems:-•;,1i.;, ::or the adequacy of Koz:311y with the designer. Additions; - t'o ,:ilese drawings after this date wii$ veouire a resubmii.ni of :'»I ,..)1.!RJr.sc.-goent approval, • Final accepta::-L suole.cr "•:'d cea and Inspection by The Tukwiia Fire Prevention but -eau. Date: /(7-21-/(0 By:)I ( • TUKWILA FIRE DEPAR771ENT Heasn cale- 206-5754407 and ofve. ti -a3 Fire Permit No. - and. ex -pct „1,,titt-ess for shut, down or testoration pproval'. WASHINGTON STATE . • CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS John J. Apia'. 9760-058143G Level 3 • . n Fire Protection, Inc. iO) • CROWN. FIRE PROTECTION IN C ORPORA TEE? P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 4-81-7669 AT&T 1010 S outhcenter Mall, Space 316 Tukwila, WA 98188 PAID C 71.• 1) 2016 TUKWILA FIFIE h 32V DATE: /0/17./ .' DRAWN: a - SCALE: • FIRE A D EALE ARM SYSTEM TUKWILA9 WASHIN ToRADDITION ETON SHEET \U v 3ER SHEET TITLE FA -01 SYSTEVV I\FORMATIO\ FA -02 TYPICAL WIRI\G A\D IVOUNTI\G DETAILS FA -03 SYSTEIV CALCULATIO\S A\ D SINGLE LI\E DIAGRA v FA -04 FRE ALAR IV SYSTEM PLA\ SHEET INDEX WI RE SCHEDULE A \D CO\DUIT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: II DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 2. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NEPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO 'FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE' ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED 23. QUANTITY E 2 2 3 3 1 E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT SMOKE DETECTOR FDBZ492 W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD DI FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM ❑Q E HORN STROBE (EXISTING) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A TEL. (206) 622-6545 SYMBOLS LEGEND NORDSTROM i LEVELS 171,)75.,1 [0:J C, 0,(0 IACPIC :PAC 7'728 I_ W<IAIIiWNNV . 10,7. 1114010 00020N (8PCLC.5 AT&T DEALER STORE T.I. #2800 / SUITE 316 macys LEVELS 250,407sf Irr WINK C,:FMD:`N l u rr 4,10N I.M. '{"..... 1.. 1:1 LO QM > ...... wl._ .I IA It GNU: .6-1-6-6.6 .... plf FP Not !*4<* L: AV NhP _ n`a, IA +1;I CLASp ,IJI r, MAN' IN WACNIN01GN N ANCNAI 1PIIVM4Tr 67,01.4,,,FAC N.I_a ans rn+l 0 STAIRS M,:M IA.n� Nnnr flnanm U Cv:u0F I0 lf,•; MILNACL NI a:: .I 001W '9 0 CLAW I 51000. O 1 nlu'1J<1i i .._. .i"_. I .....� 'nu a'0 'LlttS• 0.f C.Aif A'C"iF., n*.:iaNU IC NG 50(1. *000 C:1 00L[ :1400.0 MF 0001 Lln[ �e. til 4 II "I. RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE (0 00 0 o CCCCC �CALE: NOT Z 0 [.. 0 z DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/18/16 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER:18252-1i SHEET FA -01 , PAID OCT 21 2Q16 TUKWILA FIRE .d2vt 3e' j/tel 7s Wil THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-601Z �I DEDICATED EMERGENCY 111 NOTE FOR ADDITIONAL SPECIRCADONS SEE PRODUCT DOIXMENTA110N. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC ISOLATE FROM' AND TO NEXT ADDRESSABLE (} DEVICE STOP IF LAST DEVICE C~ FROM XLS CONTROL PANELCf OR PREVIOUS ADDRESSABLE DEVICE 0 0 HTR) -R 0 0 O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE U PAD -3 001°1 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NA,C4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - 1 3.6k EOL (-) (+) 2 SPARE 2 SPARE SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 5 m z S 0 C3 0 -� rci F, 00 C)(-) (+)(+) P1 m 0 F1 0 Cr /A 3-4 (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPLIFPLR RED (JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC S'. FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O o F GROUND 7)-1 0 d GA0 ;2) u'I La] © 0 0 HTR) -R (-) (+)> TO NEXT DEVICE OR 3' STOP IF LAST DEVICE DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL C HORN/STROBE OR STROBE ONLY C 0 HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32' F 0' C TO 100' F 38' C) HUMIDITY: -9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR — FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE rDATA IN( ) DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR - DB -11 / STANDARD r SMOKE DETECTOR BASE (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 ' TO NEXT DEVICE 0 0 --CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 2 0 DESCRIPTION SHOP DRAWINGS DATE 10/18/16 1 z CCCCC W L�OF-T' 0CC --co (n Z <�� cr'4z w (/) Q w LIJ 06 CC Si < N �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/18/16 BACKROUND PLAN PROVIDED BY: �0B NUMBER: 18252-1} SHEET FA -02 FIRE ALARM BOOSTER Project: AT&T DEALER STORE Panel: EXISTING PAD -3 BOOSTER Date: 'October 19, 2016 Module/Device POWER T.I. POWER Qty SUPPLY SUPPLY Standby (mA) BATTERY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 30 . 30 0 30 30 0 A . TOTAL FIRE ALARM POWER SUPPLY 30 30 00 0 B Auxiliary Device Current 0 0 C D E F G H 1 J K Notification Appliance Load (Max. Total / rnA) 0 3775 2CCCCa Total(A)= ' 30 Total(B)= , 3805 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 30 3805 Total current ratings converted to amperes (line D x .001) 0.03 3.805 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.72 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.3169565 Add lines G and I Total Standby and Alarm AH 1.0369565 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 1.2443478 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: AT&T DEALER STORE T.I. Panel: EXISTING PAD -3 BOOSTER POWER SUPPLY Date: October 19, 2016 Wire Resistance 2.58 CURRENT TOTAL 3775.00 ZH-MC-CW @l5cd 2 ZH-MC-CW @30cd 2 ZH-MC-CW @75cd ZH-MC-CW ©95cd ZR -MC -W @15cd 1 . ZR -MC -CW @l5cd DEVICES 5 87 131 222 292 64 69 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E ) EOL Voltage 0 262 444 0 0 69 775 14 225 23.10 (WL*2)*(R/ft) (Total Cct Load) (E= 1 * R) 24 - E) 775 1.16 0:78 0.90 23.10 DEVICES 'FULL LOAD TOTAL mA= 1500 Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E ) EOL Voltage 24.00 1500 (WL*2)*(R/ft). (Tota 1 -Cct Load) (E= I * R) 24-E) 0.00 1.50 0.00 24.00 DEVICES FULL LOAD TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL. Voltage DEVICES :FULL LOAD 1500 24.00 1500 (WL*2)*(R/ft) (Total Cct Load) (E=I*R) 24 - E) 0.00 1.50 0.00 24.00 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E ) EOL Voltage 24.00 0 ( WL * 2 ) * (R/ft) 0.00 (Total Cct Load) 0.00 (E= I * R) 0.00 24 - E) . 24.00 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS SYSTEM CALCULATIONS TO EXISTING , POWER SUPPLY EXISTING TENANT J -BOX TO NEAREST EXISTING DATA LOOP J D FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. s Ess � s � bEFAAA/- EOL S2 S2-1 S2-2 S2-3 S2-4 S2-5 15cd 75cd 30cd 30cd 75cd REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 00 0 2CCCCa M CC z009 O ��� ��'z <_F- CCL §z J W� <z W cc v a �S I— o < c0 CV "CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:1 0/18/16 BACKROUND PLAN PROVIDED BY: \JOB NUMBER:18252-1} SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved ( SHEET FA -03 7,---7;t7nr . • gl Without: Ccif.T.u.;- As Noted in 0 Per The Attadiiitette The c- cgans have, tleeli (eviewed tY e Tukwifa Re Pr r !deIrt Bure4(1 r:.nformance with current City si Acczv- bectX ercers and of)-! ,ons !whfr.:1-4 i,,Ithocke kftiztr,ril; of adopted !'-as endor6i7.!--17-1ce-,,. The resE,Donsibility for the ad! cles;9!•! .r.:omily with the designer.. Ac. de1etcav ...-evisions to these drawings after tt te wi viC. :Icceptance afld f equire a reaubralttei 4:!Jf iraWr1g5 for stitiseqi.vr...1.nr. approval. Final acceomnce suosect to flea test and inspection by The Tukwiia Fire PfeVenCiOn !Bureau. Date: iC)-)•L- -IC- By: TUVIL DEPARTMENT 4-!!,;6-575-1407 and give th'k3 Fe. Permit No, 1G and exact acc'„reiss for shut- '1. down or Antonztion 'approval. TO TENANT J -BOX CD— D S? -2 cd S SH D /14D t EN 1HT-R HT -R L S2-1 )) 15cd 7,1 ') ri- WEAR MWU • _1 r VALUE—T MWU FSLS MAW LT—S ,/ s c( (H:4! , ;/ LT—D AATV—BENCH S2-3 30cd 1:4D I HT -R1 TSM QMI 2 BP EK1 S2-4 30cd MWU MWU SPT3 I f SPT2 LT -S LT—D LT -S 1 LT -S MWU MWU SPT1-T POWER LT -C LT—ADA LT—C MWU iPAD !I BP MWU MPOS FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. PERS a_ MWU PROT 1r MWU c MT Ei<Fm44_ EOL S2 S2-5 75cd 0 MPOS-ADA SECURITY GRILLE TRACK MALL TILE/LEASE LINE SOFFIT ABOVE / 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG 1 DESCRIPTION SHOP DRAWINGS DATE (0 0 2 <<<<< DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/18/16 BACKROUND PLAN PROVIDED BY: .JOB NUMBER:18252-1i (* SHEET '\ FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved