Loading...
HomeMy WebLinkAboutPP - 1021 SOUTHCENTER MALL - BODY SHOP - PERMITS AND PLANS1021 SOUTHCENTER MALL ASSOCIATED PERMITS 13-F-038 13-F-037 13-S-028 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: (0 Z \ 6O \AV CXie -k ( fl &. Tenant Name: t i\L 60 Li & o�D Property Owner's Name: Uj 0.5k Fl P. k d ` L L C Mailing Address: 2 %bO 60v An( ca (. CONTACT PERSON -if there are questions about the submittal. King Co. Assessor's Tax No.: Suite Number: It% Floor: New Tenant? ® - Yes ❑ - No 1 1VLtJ L„s City State Zip Name: 031a n A Day Telephone: 11 Z S Li 1 (4 4 Company Name: CC DU-) (\ fire, Pio -1'G6-o (\, Inc -- Mailing nLMailing Address: O 6 b 7i [2 03 3 rn +' l Gf'(Q W 1,.) A 1S062- State Zip � r► E-mail Address: �j� � (, rn 6on E 7 s (O v1' 1 City Fax Number: Li keg s Total number of new/relocated devices or sprinkler heads: vl Valuation of Project (contractor's bid price): $ 210 0 0 (n� �A Scope of Work (please provide detailed information): J. 1 0 L (Att t ^ ` 1 ser; (\ tee r eo.. s 1 c r 3f(\&,c\k I (r2toJerreno- d 0(\ P >(. Space. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGE Signature: D Print Name: uC _ C 5 k" QC( ckn A Plan Permit App.doc Day Telephone: Date: ( [31Ii3 L z L (7(DY 1/2/13 TFD FP Form 8 44130144 SITE LOCATION 1Oa1 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 20 ` J -3-- "U Cf U Site Address� 9CXAAAaAVIVAV I i Suite Number: 2��—"1 Floor: Tenant Name: —ALL U CL\ <J V New Tenant? IJV - Yes ❑ - No Property Owner's Name: i,5\-c,,,A a U .c, Mailing Address: rl, t \Ni 'll Wk (t MV6t - Lk ((CJS f State Zip CONTACT PERSON -if there are questions about the submittal. Name: KARINA VELIZ Company Name: GUARDIAN SECURITY SYSTEMS, INC Mailing Address: 1743 — 1ST AVE S E-mail Address: kveliz@guard iansecurity, com City Day Telephone: 206-734-6276 x229 City SEATTLE, VA 98134 State Zip Fax Number: 206-341-9928 Valuation of Project (contractor's bid price): $ 7f 2 ---COO Scope of Work (please provide detailed information): c CJ 4u S -h1 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: vu WNER OR AU HORIZED AGENT: Plan Permit App.doc 5/14/10 Date: -117 l17 Day Telephone: 9(1_, L ( • 6-g9 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: The Body Shop 1021 Southcenter Mall Permit No.: 13-S-028 Date: February 4, 2013 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. SHEET \UvI3E1- S THE CHILDREN'S PLACE FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON EET TITLE FA -01 SYST IM I\FICHNATIO FA -02 TYPICAL_ \G A\ D MOU \TING DETAILS FA -03 SYST ik/I CALCULATIO\S A \D SI \CLE LU\ E DIAGA FA -04 FR = ALAN SYSTEM PLAN SHEET INDEX Without Comments s ❑ As I\lotz?'G in Rc ❑ Per The Attacf k:X, These plans have been reviewed by The Tukwila Fire Prevention Bureau f _ r conformance c;;c ; current City ;.;t1ndards, Acceptance is suoject to errors and s C s which do rot =:i_ tt or!7F ��iol tion:T of adopted omissions v - - r•.in:.'r?i_ ,s me responsibility for the �,rli�ards and crcT - E..clequacy of des gi . i e : totally with the designer. "Additions, deletions or to these dra v:ngs after tris nate will void thi ?tance and will require a resubmittai of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention urea i. Date • - - � 0 -1 � BY - - SYMBOL DESCRIPTI❑N NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and t+ 'amination of the testing. DL LE A\3 CON D U IT FILL CHART WIRE DESIGNATION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE STROBE SYNC DATA LINE -ADDRESSABLE LOOP DEVICE POWER - 24VDC STROBE CIRCUIT - FEED STROBE CIRCUIT - RETURN SPEAKER CIRCUIT - FEED SPEAKER CIRCUIT - RETURN REMOTE INDICATION LIGHT NO. OF CONDUCTORS TWO TWO TWO CONDUCTOR TWISTED PAIR WITH SHIELD TWISTED PAIR WITH SHIELD TWO TWISTED PAIR W/ SHIELD TWISTED PAIR W/ SHIELD TWISTED PAIR TWISTED PAIR TWO #14 #16 #16 #14 #14 #14 #14 #18 FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) CONDUIT FILL CHART VOLTS WIRE SIZE 600V #12 AWG 600V #14 AWG 300V #18 AWG TYPE THHN/THWN THHN/THWN TWISTED FPL TW CABLE DIMENSIONS AREA .244 0.D. .210 0.D. .156 0.D. .0467 .0346 .0191 CONDUIT FILL CALCULATE THE DIAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1 /2" 3/4" 1" .12 SQUARE INCH .21 SQUARE INCH .34 SQUARE INCH .60 SQUARE INCH .82 SQUARE INCH 1.34 SQUARE INCH FIGURES ARE BA_ ED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT F'❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END i 7.rKWILA FIRE DEPAR i ME` -NT r Peas c ii 206-575-1407 and give. Cii;� isa.iti:BriiS'w 13_ - 1 and for shut, down r.-, ova. WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vaC POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FRCM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL LEAN -UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A AT ALL DEVICES, LABEL JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO FROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX EX 1 1 2 2 3 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP ® SMOKE DETECTOR HFP-11' W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP • CEILING W/ 1G RING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM ❑Q FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXTN FIRE ALARM SPEAKER STROBE SET -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXTN TO BOTTOM A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 71, 5si It s�. macys L LEVELS 250, 4 07s i •- .Jj 3.;w SEARS & o u a TS GeN_PA 3 ^..:cJ , t & P-AYTCYN mervyws 2 LEVE1S 65,237sf PArtCSS • LJ✓iP F!;bI 0 V • - JCPeruiey LEVELS 3 LEVELS 276 4i8sf THE -CHILDREN'S PLACE STORE #1322 1 a TpRE PATO SITE PLAN PAID FEB 05 2013 TUKWILA FIRF oe y 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: m 0 DESCRIPTION SHOP DRAWINGS w F-- <1 c 02/04/13 2aa<<< W U 11. Z w CC0 J U w z Z ,co O <� C G� < WUte W • ZZ rri �J WCC `zbDCE SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/04/13 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved BACKROUND PLAN PROVIDED BY: .10B NUMBER: I SHEET FA -01 I THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE + , STOP IF LAST DEVICE DUCT DETECTOR LOCATI❑N OUTLET SAMPLING TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND / \ I AD2-P DUCT DETECTOR MOUNTING DETAIL 0 FROM XLS CONTROL PANEL OR <-1- PREVIOUS ADDRESSABLE DEVICE END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH /0 T A 0 0 GROUND Ln 0 O HTRI-R OSTATUS LED 03 0 N.0 0 COM (Q N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 MUSIC : AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - 27 VDC 3.5 riA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0,02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. 0 O 123456 [B2 c © O 6 5 +- 4 3 2 1 JUNCTI❑N BOX MOUNTED ON `, CEILING. FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE + DEVICE LOOP NOT USED REMOTE �I , DEVICE LOOP `. 0 0 0 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> O O ? TO NEXT DEVICE v a / / / / / 0 O --CADDY BAR SMOKE DETECTOR ------ SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL 0 GND N AC 0 0 0 YT TT 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 24K HCP MODULE ( PAD -3 TRIP) WIRING DETAIL NAC -4 NAC -3 2 NAC -2 NAC -1 470 OHMS EOL TSM -1 0 0 • -12-3-45- AD2-P DUCT DETECTOR WIRING DETAIL FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) 0 0 EARTH GROUND --).(+)TO NEXT DEVICE OR —*(-) STOP IF LAST DEVICE l ) ( ) STROBE SPEAKER (+) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TINGTEMPERA RE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 1-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —1 -> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION NATH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE TO NEXT DEVICE REAR VIEW > ( ) DATA OUT > (+) DATA OUT HFP-1 SMOKE DETECTOR WIRING DETAIL 0 (+) (-) STROBE (+) ( ) STROBE SPEAKER (+) (-) n SPEAKER STROBE & STROBE WIRING DETAIL SPEAKER STROBE OR STROBE ONLY R 0 TYPICAL WIRING AND MOUNTING DETAILS 4S DEEP BOX w/ 1-1/2' EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) HARD LID CEILING '- --SPEAKER SUPPORT TILE BRIDGE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N N\\ CEILING MOUNTED SPEAKER/STROBE xx SPEAKER STROBE & STROBE CEILING/WALL MOUNTING DETAIL RELEASE/REVISIONS (REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 02/04/13 2 as«< iS-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/04/1 3 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 1- SHEET 1 FA -02 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SPACE 116 LANDLORK WORK EXISTING SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: M d' 0 N 0 2 «<<< Device Type Qty Amps Total Amps Total HTRI-S 0.0096- 0 0.0021 0,000 Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -W @15Cd 14 0.0096 0.0192 0.064 0.896 SET -MC -W @30Cd 9 0.098 0.882 SET-MC-W@75Cd 3 0.175 0.525 SET -MC -W @110Cd 1 0.0827 0.233 0.233 Amps SET -MC -CW @15Cd 2 0.069 0.138 SET -MC -CW @30Cd 2 0.111 0.222 SET-MC-CW@75Cd 6 0.2 1.200 SET-MC-CW@95Cd 1 0.264 0.264 ZR -MC -W @15Cd 12 0.064 0.768 ZR -MC -W @30Cd 0.098 0.03 Amps 5.158 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 5.158 Amps For 5 Minutes= 0.433 Amp -hours 25% Derating= 1.442 Amp -hours Total System Current Load: 1.442 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH fir �Ilyz 9 `�ifi �� I�'wY4 (� 9��� P A�''� w "I�i R .'.0 .:'', DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: M d' 0 N 0 2 «<<< Device Type Qty Amps Total Amps Total HTRI-S 0.0096- 0 0.0021 0,000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.0096 0.0192 0.021 0.042 0.0827 Amps 0.106 Amps Notification Appliance _Circuit Detail PROJECT: THE CHILDREN'S PLACE Panel: EXISTING PAD -3 POWER SUPPLY Date: February 5, 2013 CIRCUIT:IS1 QTY Device Type !Alarm Current SET -MC -CW @15Cd i 69 0 3 !Wire Resistance 2.58 CURRENT TOTAL=' 734 Alarm Total Wire Size I Wire Length ` Voltage at EOL i Circuit Total SET -MC -CW @30Cd 111 I SET-MC`CW @75Cd I SET -MC -W @30Cd ;SET-MC-W@75Cd SET -MC -W @110Cd ZR -MC -W @15Cd _ . I ZR -MC -W @30Cd 981 0 DEV10ES=17 TOTAL mA=j 734 14 333 200 0r 98' 98 175 175 233 0 64 128 CALCULATIONS 390 18.9228984 734 iTotal Wire Resistance ( R (WL*2)*(R/ft) ;Total Device Load, Amps (I) (Total Cot Load) :Voltage Drop ( E) (E=1* R) EOL Voltage (24 - E) 2.011 0.73 1.48 _ 1 22.52( v,vI TO NEAREST EXISTING SPEAKER CIRCUIT TO NEAREST EXISTING POWER SUPPLY s6 TO NEAREST EXISTING DATA LOOP EOL S1 1 r J � s,v,vI (J -BOX LOCATED AT HALLWAY INSTALL STROBE CIRCUIT EOL RESISTOR INSIDE J -BOX) 13') S1-1 75cd S1-2 30cd S1-3 15cd S1-4 15cd SINGLE LINE DIAGRAM S1-5 30cd S1-6 30cd S1-7 30cd FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. CONTRACTOR SHALL VERIFY EXISTING DUCTWORK LOCATION. EXISTING SMOKE DETECTOR TO BE RE -USED. CLEAN AND TEST AFTER AIR BALANCE IS COMPLETED. PROVIDE ACCESS PANEL(S) IN NEW CEILING AS REQUIRED TO SERVICE VAV BOX, TEMPERATURE SENSOR AND SMOKE DETECTOR. x 3 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG i DESCRIPTION SHOP DRAWINGS DATE M d' 0 N 0 2 «<<< W z -c � J 00 a-- z (j) Q W Z w zZ CC°C 0 2 =d- WMA LU rc Iz SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/04/1 3 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 1 SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved �/ 'Y's; •-;j: • "! -=,:' /E. iTO'NEAREST EXISTING : -7SBE3ER CIRCUIT ORITE ; ! TO NEAREST EXISTING POWER SUPPLY v,v 6 COLJ L WA 1 GC SHALL INSTALL HM 0 ...... POOR FRAMES PRIOR INSTALLINGFLOOR FINISHES, TYP. 1 ACT -EX 5'-2 I/2 /7 I 21-11 5/4" FITTING 001\il 102 WC -1 , FC -1 8-1 ; ACT -1 ....... ... ..... COL JANITOR CLOSET 105 PT -1 ..... 8-1 ACT -EX COL "r-10 1/4" 11 A EOL - t TO NEAREST EXISTING DATA 6, LOOP -.'. • , • - ID< S1-1 75cd IH -R 1 I TSM I l-4 5Y4" • S1-2 PRINK!N 30\ Cd,_,,,,, le„,„ i r.......,,, — 1 51..111 ..• -- • FOUNTAIN ---, . -.., 22-7- : --- ; I \r I i-- -:, \ 1 / ICO • • \ I .6.--------,,S1`..v. '(-: ' = (...-- 177/ ---'9 L; I tr • • 1/", ID 5. 1,z r -r-: T (`I ••T 6 S1-3 15cd k-eSekir C1C1 I212» . ..„ St:4. 15cd 0 • • • • . . • ......... t 11 EXISTING TOILET ROOM 103 WC -1 FC -1 8-1 PT -1 I I I 1 \ h I — - / \ /-\-- /4U\ sit \ HOLD \ \ PROVIDE WHITE CORNER GUARDS "C6' " TO 1'-O" A.F.F., TYP. 5 " LL\38 I/2 HOLD \,c) co y IHT4RI 1; 0 \< FOR STOCK. . SHELVES, ETC. SEE A2.0 F 1 XTURE FLAN S1-5 30cd 4%-0" --/ - ARMOIRE S,S'IV,V CRAZY 0 -- EXIST. DEMI SIN& WALL, i MAINTAIN ALL FIRE RAT 1 N(*.' FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. CONTRACTOR SHALL VERIFY EXISTING DUCTWORK LOCATION. EXISTING SMOKE DETECTOR TO BE RE -USED. CLEAN AND TEST AFTER AIR BALANCE IS COMPLETED. PROVIDE ACCESS PANEL(S) IN NEW CEILING AS REQUIRED TO SERVICE VAV BOX, TEMPERATURE SENSOR AND SMOKE DETECTOR. oU , , - •••••. to 1/"O' 55'-5 1/4" LEASE LINE \ /F---;:f-;,-J,Ic,, , 2s -0/a 1 1 5v" '-7 1/2", : ''.'N 1 -i ;- ' 15'-0" N.J I 1 : ; „,,,,,, ,,,,,,,,,,,,,, ,...,,,,,,,...,1 .:,..ux..f..,x4,....j MV,÷37.4.4` 4-'3:.i. 51'.i...." 4-`..a.k'sr.-;Zr 4-..:,..i5.... V.Z.2.,"-2-4r.V.,-3-i7.".• i !ZI2c;.-1--`.7,Z2-'5..V,C-3 Wt.' r,-i."-&`4"W.‘-leSSNg .--2.;.'..'"--;e:-'W 1-a:k.',1i,"2--r-is.' "r.A.' ,l'''''S' `.... i.V. k '''' '--"--i•'''''ke`'''-`' '"'''' ..'"4"C'' ''''"''' ' "i"V ' ' - '‘' '"-±N.". :;';' ' ''''''''''' ' ' '`.." ,' ^-,* '-' ." ""' " ,<" \ i" "w.4-1"1,-"'' 4 ' .....'0,-'.( '''),' ''. ) "...,\,',..).' . ''÷'..- '''''' .,. , III i'l I/ . I I ) Ali 1 . ...,)• • #.... ": I _....„ i C > :,,,•!: , > i < . Y.•,, 1 f; , -,, ‘,..: ; ;•:;,i :, I 4N. 1 ._...%,:s / i ' oii;11--Z.L'i HOLD 141-6," ARMO IRE -- 7 101-62" 41-6' HoL: 61-6" r4i1 . i "1......„ 1 .• 1 %, , < A '‘ •!",',. HOLD HOLD 1 li kit; ',I , ARMOIRE ;i Ill i 1 lt ^ 44 1 11 '1 , 3'-5 / 1 i 1 .,1-/ 1 1 1. 1 i .:, r- A SALES ,S f PT -1 i 8-1 . ....... . DISPLAY WINDOW 100F PT -1 B-1 1 PT -1 1 A I LEVEL 5 FINISH IN ALL VISIBLE AREAS, UNLESS NOTED OTHERWISE. i LEVEL 2 FINISH ALL OTHERS, TYP 1 i : ...:!.../ ... If,:I.,'',.'--',!_3,..:H..1•..1.;.• 1.'•....:. . .... _ / /;- ‘ I & '-6 " ' 4• 1_0:: (;) 4 '-0" Ii e ,, , 1 2 ' -q " I46:! - u " / 7 7 /-/ 7 , 1 -(LD ARMOIRE HOLD 1 ARMOIRE HOLD - 41-0" <.... t, • ; ;I 1 1 H:_: AR MOIRE 515 :A,7 11:/.t . ,,.„__ —,— .,...„•,...•:„.„.:•_>;:-„..„.„...t..,..„.„:„..:.-,..,.„,,.....,..-•1.,.K: it ; r ,.. L-"`----XL'N'.-. 3:-s ---:-.....-..........,.....r.,Z 3K, ,!..?......._ : l r ! i 1 _" ! .,',•/• ...„ ,,,„Sn,.V->ri,:e.-..-> : -. - ',......,.— /11— •• ;>:-:.,,. .,-,...7,.i. -'' W[ 1 S1-6 30cd CASI-LVW_2 CA.SI-LWRA_3 ... HOLD - L3btdOr SOFFIT AVE ' OLASS DOC.'/RS AND STOREFRONT SYSTEM ..• LEVEL 4 FINISH AT DISPLAY NINDON ONLY, TYP. CHILD SAFETY i3ARRIER... SEE DETAIL 2/AI.1 -TYP . " . ... • • " • ....... LEVEL 4 FIN 1^11N001" ONL '.. I. '. .. t • k : *II i.- ..__ • ••-- „..5!::..... .: 1 1 I 1 ; ' 1 1 1 1\::::11\11,7.4. I \." \ 1 / \ S'.- ..kLEVELNi7,- ,,,:ONL,,N 141-6," HOLD It 1 / = ; / 1 i _ 1 1 ,t- • t I I 2 3/4 "-) 1/2 " DISPLAY WINDOW " I I ..... 1-11 5/4" 'Hi 1/2" S TO :C -K ROOM • 104 ... ... ...... .... PT -1 ; T ACT -EX 1 I/E," 12 '-&" 100'--6 I/4" LEASE LINE HOLD L.LOVE CULTURE I FIRE ALARM SYSTEM PLAN -1 van - - -/-/- - - - - : - 1 0 OF PT -1 FC -1 B-1 j PT -1 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 3 ISI AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 02/04/13 2 <<<<< LIJ co z _co gzs9 z u ZZ 1.1.1 11.1"± - CE >" (-) i„.„‘ 2 0 < c\I OW CC co LU ‘CALE: 1 /4' =1 0 DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/04/1 3 BACKROUND PLAN PROVIDED BY: \:...JOB NUMBER: 2 SHEET FA -04 53'-7Y"± TOILET ROOM STOCKROOM /OFFICE 11/ 0. Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or an other All heads to be at least 6' apart Y means ® 9 — Relocate Reliable Model G5 Standard Response 1/2 • E — Existing pendent no change p 165 Pendents /z x 9 — Total PLAN NORTH REFLECTED CEILING PLAN 1/4" = 1'-0" without Corriments_ As Noteci.irl Red Per The A t ci = .d Letter These plans have been rev€e ed by The Tukwila Fire revention Bureau for ccnfbrmarice-With Current City ;tandards. Acceptance is subject to errors and omissions which do too;. authorize violations of adopted - ar}dards and ordin &nc::s.. The responsibility for the adeouacy of design totally with the designer. Additions, de.i=Oti; t r .evis€ons to these drawings after this date will vc,t. t=;:r�. acceptance =ce and w€€€ regu re a resubmti1ai of revised drawings for subsequent approval. Final acceptance Is subject to fel test and inspection by The Tukwila Hre Prevention Bureau.Date:. _y —I E>;: TLKNILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. 13 So and exact address for shut- down hutdown or restoration approval. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TDP BEAM/ C—CLAMP WITH SET SCREW 3/8' ALL THREAD RDD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS TME BODY SNOP ijkilh 20€€1 „ ,: Sea!ab Opy MsketpYpl a eM • MMI NORM STORE LOCATION PLAN SCALE NONE PLAN NORM CROWN FIRE PROTECTION. INCORPORATED P.O. BOX 12113 M€LL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7869 The Body Shop Southcerat er Mall Tukwila, WA 98188 'AID . FEb 01 2U13 TUKWILA FIRE -#.z7SGi5 DATE: 1.; 3 1.1 DRAWN: O SCALE: 1 J 9 aF ThE BODY SHOP FIRE A 3 ARM SYSTEM ADDITION UKWILA, WASHINGTON SHEET NUIv 3E SHEET TITLE FA -01 SYSTEVI ATION FA -02 TYPICAL WE I\G AN 3 v OU\TI\G DETAILS FA -03 SYSTEM CALCULATIO\S AND SI\GLE LI\ E D IAG AIv FA -04 FRE ALAIv SYSTEM PLAN SHEET INDEX F `fv Withou.ut Comments ❑ As Noted in Red O Per The Attached Letter These plans have ben reviewed by The Tulwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or +eviii0116, to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and Inspection by The Tukwila Fire Prevention Bur Date: 2--2 O -L3 BY: NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. DULE AND CO\SUIT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Firs 'Permit No. __/. is -037 and Xact address for shut- down hutdown or restoration approval. FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO ARE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE VIITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 1 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD -3-ENCL 66" A.F.F. TO TOP ® SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING ® D DUCT DETECTOR AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM- 1 SIEMENS 1 -GANG BOX VERIFY II\I FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM Di FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A it/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A NSA RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 171,2755f 1.5.4:75S3 8 NCYORIA5 SCCRET =.�pnrm s,N2+sI * L macys 4LEVELS 2 C,as.sf m SEAM 4 nc.y,g ,K1144F ,YVILUtrl n, THE BODY SHOP STORE #1126 / SPACE #126 PAID PERS 05 21113 TUKWILA FIRF 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE M c 0 N 0 2aaaaa co cV CO T eL O Ur r OE C o (.1)`-1- C0 �- w �z tJ, WCn O CO Fcz� <Li" F -E tY 80 LL co O 0 0 N } N �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/04/13 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 1- SHEET FA -01 WIRE DESIGNATION GENERAL NOTES SITE PLAN cc 707.0`' Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved //,W --7S /?o,/ THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 12OVAC-60HZ DEDICATED EMERG(NCY NOTE FOR AODIIRINAL SPEOFICAI ONS SFE PRODUCT D00AIENTAfl0t *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC ESE PANGROIMTK TO NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE - FRON XLS CONTROL PANEL (+ OR PREVIOUS ADDRESSABLE DEVICE - D 0 I= 1 n GROU ND*J- : u HTRI-R � C 0 O 0 O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE POWER SUPPLY & RELAY MODULE WIRING DETAIL FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. m S P1 m 0 0 P1 P1 0 z 0 5 m m c Q N o m o o t, 70 m o -1 V) (-)(-) (+)(+)v (+) O WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTEDPAIRW1TSHIELD #18 FPLIFPIR RED(JACKET) *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 u g /I HTRI-R 00 GROUND � (+)) TO NEXT DEVICE OR 0 a 0 O (-) STOP IF LAST DEVICE } DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL TO NEXT ADDRESSABLE DEVICE 0 FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE HOOD EOL GROUND 0 0 0 CO 0 HTRI-S STATUS LEE 0 co 0 0 0 NOT USED 0 O HOOD MONITOR MODULE WIRING DETAIL (-) (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC F1ED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY v u HORN/STROBE CR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER6TING TEMPERATURE: +32' F 0' C) TO 100' F 38* C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR \ -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE 440. 00 O 0 DATA IN ( )>- DATA IN (+) > DEVICE IS USTED FOR AIR yaw( APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION MATH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /- HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID--\ CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT o o TO NEXT DEVICE -----CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS ZIC W N O V �'S Q 1� co z co CL, OQ T mr-O a. VJ rr�� Q J VJ Q W Z CC I � to w Q 4CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/04/13 BACKROUND PLAN PROVIDED BY: .0B NUMBER: I. SHEET FA -02 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved ,/ Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HTRI-S 0.0096 0 0.0021 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.0096 0:0192 0.021 0.042 0.0827 Amps 0.106 Amps Notification Appliance Circuit Detail PROJECT: THE BODY SHOP Panel: , EXISTING PAD -3 BPS Date: ;February 4, 2013 Wire Resistance 2.58 CURRENT TOTAL= 236.00 jZH-MC-CW @15cd 7/1- IC -CW @30cd 871 131 174: z�-l-nnc-cw @Teed 2221_ ZH-MC-CW cx 95cd 292 173 -1 -.MC -CW @135cd 1 ZR, MC -W @15cd DEVICES j 4 SYSTEM CALCULATIONS 371 64 TOTAL mA= 'Total Wire Resistance (R) Total Device Load, Amps (I) ;Voltage Drop ( E ) EOL Voltage 23.74' (WL*2)*(R/ft) (Total Cct load) (E=1*R) 24-E1 236: 1.11 0.24 0.26; 23.74 TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-1 S1-2 S1-3 S1-4 1 5cd 1 5cd 1 5cd 30cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I XISTING SiEMEI' S- PACS 3" g ►a1 Extender - art et ! L.ci d°Ca idyl ctitir DESCRIPTION SHOP DRAWINGS Current Load. � fSta b" nd 02/04/13 Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW @15CD 11 0.0875 Z1 -1 -MC -CW @30CD 12 0.131 ZH-MC-CW ©75CD 3 0.222 Z3 -1 -MC -CW @95CD 1 0.292 0.292 23 -1 -HMC -CW @135CD 0.371 ZR -MC -CW @15CD 7 0.069 0.483 ZR -MC -W @15CD 6 0.064 0.384 0.03 Amps 1.189 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.189 Amps For 5 Minutes' 0.100 Amp -hours 25% Derating= 1.025 Amp -hours Total System Current Load: 1.025 Amp -hours R Bath..,.. Pa: to be Used:. 12V - - `. 7.2AH` Notification Appliance Circuit Detail PROJECT: THE BODY SHOP Panel: , EXISTING PAD -3 BPS Date: ;February 4, 2013 Wire Resistance 2.58 CURRENT TOTAL= 236.00 jZH-MC-CW @15cd 7/1- IC -CW @30cd 871 131 174: z�-l-nnc-cw @Teed 2221_ ZH-MC-CW cx 95cd 292 173 -1 -.MC -CW @135cd 1 ZR, MC -W @15cd DEVICES j 4 SYSTEM CALCULATIONS 371 64 TOTAL mA= 'Total Wire Resistance (R) Total Device Load, Amps (I) ;Voltage Drop ( E ) EOL Voltage 23.74' (WL*2)*(R/ft) (Total Cct load) (E=1*R) 24-E1 236: 1.11 0.24 0.26; 23.74 TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-1 S1-2 S1-3 S1-4 1 5cd 1 5cd 1 5cd 30cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 3 D DESCRIPTION SHOP DRAWINGS DATE 02/04/13 CC ac 0 w z csi J T w z w co -� O 0 0' -0 z z cn 2 Q(-9 �- wiz z Q w z wco=S O 2P - r J 0 w F-- (/) (1) "CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/04/13 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM .OB NUMBER: Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved C SHEET FA -03 1 TO NEAREST EXISTING FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. POWER SUPPLY S1-1 15cd TO NEAREST EXISTING DATA LOOP 30cd FIRE ALARM SYSTEM PLAN IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 (206) 622-6545 j w F- RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 02/04/13 co N T co O T OE I a �o (/)<-- 2 Q0 >.- w z O Q w Sog _ `` LcLEI aD w1— (0N 2 W u. �CALE: 3/8"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/04/13 BACKROUND PLAN PROVIDED BY: JOB NUMBER: Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -04