HomeMy WebLinkAboutPP - 1027 SOUTHCENTER MALL - TCBY / SCHNOO YOGURT - PERMITS AND PLANS1027 SOUTHCENTER MALL ASSOCIATED PERMITS 10-F-039 12-S-177 10-S-029 a CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION /&1 G �� /nail King Co. Assessor's Tax No.: Site Address: ��'# V 5Q(.J1;� eRn—ler' // /�/l Suite Number: Floor: Tenant Name: Tcgy New Tenant? ❑ - Yes ❑ - No Property Owner's Name: uT-c\ekQ, Mxylot rr y`-1- �� r �V' Mailing Address: JJ�l CONTACT PERSON -if there are questions about the submittal. City State Zip Name: c)e.sstatiotristri Day Telephone: WS • 4718Y Pt '? Company Name: C OUOVI F\f", Prat iW i , t nyt, Mailing Address: ?O ?xv�_121�3 m A Ci,ee z 1),_.14\ 412-0E2._ City State Zip E-mail Address: jeSS\ C Y'(l ? • C OM Fax Number: 4125 4/0- 8qs- Valuation of Project (contractor's bid price): $ 9:M -6V Scope of Work (please provide detailed information): r f(x (?) \A Q C6\0Cc Cts 4S PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING • WNEj . OR AUTHORIZED AGENT: Signature: 1 Print Name: ,Jef cini nsoT Plan Permit App.doc 5/14/10 Date: O ' t/Q 'l2 Day Telephone: 42-4014.12q 11.1) FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: TCBY 1027 Southcenter Mall Permit No.: 12-S-177 Date: August 8, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. GUARDIAN SECURITY LIFE AND PROPERTY PROTECTION 16_6_ cOPY Attn: Alan Metzler Seattle • Silverdale • Bellingham Subject: Schnoo Yogurt —1027 -- VVestfield Mall 1743 first Avenue South Seattle, WA 98134 Tel; 206.6226545 Fax: 206.341.9928 For this space currently being built out and finalized they have 1 existing Ceiling Mount Speaker/Strobe (SET -MC -CW) that was reinstalled. We as Guardian Security pre -tested this device and it works correctly. Per our conversation the intention is get a Fire Permit Number generated with this letter and call in for a Fire test with Tukwila Fire Dept. Please do not hesitate to call me with any questions or issues you may have. PS: 1 have attached the Data sheet of this device to this letter. Td WtSE:60 OTOS 80 •J1eW Thanks, Raedeit Kifle PM - Guardian Security (206) 359 1268 — Cell rkifle a Guardian Security 0661 -8E9 -90E: '0N Xdd I e$K W1LA FIRE DEPARTMUR Please call: 575.401 and give this job No._iO -F-03 C/ exact address for shun . iwn or restoration approval: .,l I dr09s Ntl I Q Idf1J : WOdd p bu,/,) ,s 4 2'0 / SIEMENS SET Speakers and Speaker Strobes ENGINEER AND ARCHITECT SPECIFICATIONS UL listed. ULC, CSFM, and FM pending. • ADA/NFPA compliant • Wall mount models are available with Field Selectable Candela Settings of 15130/75/110cd or 135/185cd (multi -candela models) or 1575cd (Single -Candela model) • Ceiling mount models are available with field selectable candela settings of 15130/75/95cd or 115/177cd. • Strobes can be synchronized using the Siemens DSC sync modules, FS -250 panel, XLS panel, or PAD -3 power supply with bullt-In sync protocol • Field selectable taps for 25 or 70 VRMS operation from 1/8 watt to 8 watts • High efficiency design for maximum output at minimum wattage across a frequency range of 400 to 4000 HZ • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires Description The Siemens high performance Series SET Speakers and Series SET Speaker Strobes provide high audio output, clear audibility, dual voltage (25/70 VRMS) capa- bility and field selectable taps from 118 to 8 watts. They are designed to meet the critical needs of the life safety industry for effective emergency voice communications, tone signaling and visible signaling to alert the hearing impaired. The low profile design incorporates a speaker mounting plate for faster and easier installation. Each model has a built-in level adjustment feature a two (2) screw grille cover. The Series SET Speaker Strobe models incorporate low current draw strobes. Strobe options for wall mount models include Siemens MC multi -candela strobe with field selectable candela settings of 15/W75/flood or the high Intensity HMC multi -candela strobe with field selectable candela set- tings of 135/185cd or single candela 15/75. Ceiling mount models are available in Siemens MC multi -candela ceiling strobe with field selectable intensi- ties of 15/30/75/95cd or the high intensity HMC strobe with field selectable 115/177cd. The strobe portion of all Series SET Strobes may be synchronized when used in conjunction with the Siemens DSC sync modules, FS -250 panel, XLS panel, or PAD -3 power supply with built-in sync protocol. Fire Safety SET -MC -R SET -CW Siemens synchronized strobes offer an easy way to comply with ADA recommendations concerning photo- sensitive epilepsy. Series SET Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing Impaired) and Standard 1480 (SpeakerAp- pliances), and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexane lens to provide maximum reliability for effective visual signaling. All in- puts are supervised and employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring. Engineering Specifications The speaker appliances shall be Siemens Series SET Speakers and speaker strobe appliances shall be Sie- mens Series SET Speaker Strobes or approved equals. The speakers shall be UL Listed under Standard 1480 for Flre Protective Service and speakers equipped with strobes shall be listed under UL Standard 1871 for Signaling Devices for the Hearing -Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 8 watts. Ali models shall have listed sound output of up to 93 dB at 10 feet and a listed CATALOG SHEET 2581 Ed WUSE :60 OTOS 80 'aeW 066P -8E9 -90E: '0N XUA J,l I dfD2S NH I QNUf1J : World frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction, All In- puts shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens, The strobe shall be of low current design. Where, Multi -Can- dela Speaker Strobes are specified, the strobe Intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd, 135/185cd, or single candela 15/75 for wall mount and 15130/75/95 cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. When synchronization is required, the strobe portion of the appliance shall be compatible with the Siemens DSC sync modules, FS -250 panel, XLS panel, or PAD -3 power supply with built-in sync protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (I.e., contacts remain closed), the strobe shall revert to a non -synchronized flash rate. The speaker and speaker strobe appliances shall be de- signed for indoor surface or flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series SET speakers and speaker strobes shall be white or red. All speakers and speaker strobes shall be listed for Special Applications. • Strobes are designed to flash at 1 flash per second mini- mum. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Technical Information For complete technical information, please consult the rel- evant installation sheets as well as the Siemens Compatibility Guide, Ordering Information / Mounting Requirements / Approvals Model Order Code Mounting Options Agency Approvals UL ULC CSFM FM SET -MC -R 500-630051 SET -MC -W 500.636052 SET -HMC -R 500-636053 SET -HMC -W 500-636054 SET•S17-R-WP 500.636058 L,P,Q,U,Y X SET-S17-WWP 500-636059 L,P,Q,U,Y L,P,Q,U,Y L,P,Q,U,Y M (Outdoor) X X X SET -517 -CW -WP 500-636057 SET -MC -CW 500-636063 M (Outdoor) M (outdoor) x # X # 4 SET -MC -CR 500.636082 SET -HMC -CW 500-636065 SET -HMC -CR 500-636064 Q,U,Y Q,U,Y Q,U,Y X # X # SET•R 500-636055 SET•W 500-6360556 SET -CW 500-636067 Q,U,Y P,Q,11,Y P,Q,U,Y X # X X # X # SET -177 -CR -WP 500-636189 0,U X MT -SUR -BOX, MT-SUR•BOX+WPS-KIT, WFPS SET -177 -CW -WP 500-636100 SET 185 -R -WP 500-636191 X # # # X # MT -SUR -BOX, MT-SUR-I3OX+WPS•KIT, WFP8 Mr -SUR -BOX, MT SUR -BOX+WPS-KIT, WFPS 5ET-185-WWP 500-636102 x X # # MT -SUR -130X, MT-SUR-90X+WPS•KIT, WFPS X X = listed/approved # = pending * = Refer to Data Sheet #2585 for mounting options. WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS, Siemens Building Technologies Fire Safety 2d W9E:60 OtiOE 80 •Lew Fire Safety 8 Fernwood Road Flurhem Park, NJ 07982 Tel: (09) 593-2600 FAX: (973) 593.6670 Website: www.abt.aiemene-oomlfia 7ro7 5M SFS -IG Printed in U.S.A. Fire Safety 2 Kanvlew Boulevard Brampton, Ontario Canada L6T 6E4 TeI:1805) 799-9937 FAX: (905)799486B July 2007 www. 066P -8E9 -90E: : '0N XbJ J,l I d10SS Nd I Q21tifD : woad 02/17/2010 10:24 4254818695 February 17, 2010 Tukwila Fire Department 444 Andover Park East Tukwila, WA Attn: Al Metzler CROWN FIRE PAGE 01/01 CROWN FIRE PROTECTION, INC. P.O. BOX 12113 MILL CREEK, WA 98082 425.481.7669 Fax: 425.481.8695 Re: Shoo Yogurt Westfield Southcenter, Space -TIM" /01 a 7 SC— M q' Tukwila, WA FILE The sprinkler head spacing is correct and the flex head brackets were installcd properly. If you have any questions or need any additional information, please do not hesitate to contact Jim Kramp on his cell at 206.605.0050. We would appreciate having this inspection done today. Th le . sica Robinson, Office Manager WKWtLA FIRE DEPARIVIVA Please call: 575.4401 and give this Job Nb. /O -S- o �q , and exact address for shuts town or restoration aporo m1 24" X 48" SUSPENDED T -BAR CEILING W/ VINYL COATED 6YP. BD: LAY -IN PANELS 24" x 48" RECESSED FLUOR. LIGHT FIXTURE SET.INTO NEH SUSPENDED T -BAR CEILING.. REFER TO ELECTRICAL PLANS. ,1,61110 r - • II REFLECTED CEILING PLAN - REMOTE STOCK ROOM fs 0 Without Comments 0 As i'c-oti.s.d in Red Or Per The Attached Letter - e. plans have been reviewed by The Tukwila Fire -antion Bureau f..: c,.711Ormance with current City •.dards. :-; oject to errors and Aisslons which violations of adopted .hdards and The resQoasibiiity for the ..equacy of des:u.. -_ , total1y with the designer. additions, delp±tr,r: c .. >v:slogs these orawings after dlis date will void ttt, acceptance ano velli require a . resubmittal of revise arawings for subsequent approval. Final acceptance is subie .t to fieiq test and inspection by The Tukwila Fire Prevention Bureau. Date: g g- l a Bv: REFLECTED CEILING PLAN • 24" x 48" RECESSED rLUOR. LIGHT FIXTURE. SET INTO NEW SUSPENDED T -EAR CEILING. REFER TO ELECTRICAL PLANS; 24" X 48" SUSPENDED T -BAR CEILING W/ VINYL COATED GYP. BD. LAY -IN PANELS SCALE: I/4" = 11.0" Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 2 — Add Reliable Model G Standard Response 165° Pendents 1/2 x %Ni 01 1 — Add Tyco Model DS -1 Quick Response 200° Pendent 1/2 x 1/2 c � n o 6 — Relocate Reliable Model G Standard Response 165° Pendents 1/2x 1/2� f m l SCALE: I/4" = 1'-0" TUB- WILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address for shut- down hutdown or restoration approval. PROJECT LOCATION CROWN FIRE PROTECTION -. INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 TCBY /p 27 000\-ceYoces V\f\ck\\ Tukwila, WA 98188 AU TUKV DATE: SJ l l_ DRAWN: G 0 - SCALE: ,L. F� PAI D N 7`72012 N /ILA FIRE �► ..#.2 n.