HomeMy WebLinkAboutPP - 1061 SOUTHCENTER MALL - CHILDREN'S PLACE - PERMITS AND PLANS1061 SOUTHCENTER MALL
ASSOCIATED PERMITS
13-S-025
CHILDREN'S PLACE
CROWN FIRE PROTECTION
SITE LOCATION
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.:
Site Address: 106'x+ S, ayi-h c, t 4t r %%laJf Suite Number: Floor:
CTenant Name: -me, t /l ef'j_ S' P/Q,c-e. New Tenant? ® - Yes D - No
Property Owner's Name:
Mailing Address:
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: < a q O i 'j jT Day Telephone: tiZS'ligl•7ede
Company Name: (` Wi1 Flre_ % s ehc %-, Inc
Mailing Address:
E-mail Address:
O $ox \2,\\3 Yil a l Creel U. -41c 9S0132 r
City yZJ ' Lla ' kto 9s
Fax Number: _ I
•
s.
`. SI.
Valuation of Project (contractor's bid price): $ 2), 500.
Scope of Work (please provide detailed information): sgeXOC/ . i ., , JJ -r V160A,S
i,r9. 1necas
PERMIT APPLICATION NOTES
Value of Construction -- In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, -for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SANTE TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING O R OR AUTHORIZED AGENT:
Signature:
Print Name: f () &Dh%?s(?
Plan Permit App.doc
5/14/10
Date: /' 26./3
Day Telephone: 7 Z4-' T V ' 7( q
TFDFPForm 8
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Children's Place
1061 Southcenter Mall
Permit No.: 13-S-025
Date: January 30, 2013
Reviewer: Al Metzler
Fire Protection Project Coordinator
(206) 575-4407 option # 2 (Inspection Requests)
(206) 971-8718 (Plan Review Questions)
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the last length of
pipe but within 6' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40 ' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2 for pipe size 2 1/2 inches and larger.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-02, section 9.6.2.6.2 (e).
• Ceilings used for flex drop attachments shall comply with ASTM C 635 and
ASTM C 636 per section 9.2.1.3.3.2.
• Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a
suspended ceiling, a hanger(s) attached to the structure shall be required to
ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3).
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
• Comply with obstructed/non-obstructed construction rules for sprinkler head
placement.
• Sprinkler heads spaced closer than 6 ft. apart must be baffled.
• Modifications involving 20 or more sprinkler heads require hydrostatic test and
system isolation if necessary.
• For dry pipe and double interlock preaction systems in addition to the standard
hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24
hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the
24 hours shall be corrected.
All code references are NFPA 13, 2010 Edition.
D Without Comments
O A5 f'• oted in Red
Per The Attached Letter
These pia
CfF entior I
- ..;•j i:.Grds.
kNin
Oiite
re5ut i;loll: t i-
ns have been reviewed iewed by The Tukwila Fire
E-..ureall for .onforrtance with current City
c,.c ..1-YeCT (0 errors and
._.',d 1i )I,ze v ;Talions of adopted
_I d. nc es. The responslb;lity for the _
'otary with l:he designer.
co (i ese drawings after
:,..-:r pta:zc: and will require a
subsequent approval.
NOTE: COORDINATE EXACT
SPACING OF STOCK ROOM
LIGHT FIXTURE -5 IN/SHELVING
DELOV1. CENTER LIGHTS
BETWEEN SHELF. AISLES, Y.I.F.
MOUNTING HEIGHT. TO
SF -I FIXTURES SHALL BE
A.F.F. TO BOTTOM
OF FIXTURE (TYP. AT
STOCK ROOM) BRAGS
LIGHTS AS NECESSARY
HALLWAY
106 .
11 =11"
ACT-E5r.,
JANITOR. CLOSET
105 l
11' -11" -FACT -EX
SERVICE I
GORRIDO
EXISTING TOILET R.00M
1.03
• 81-0" PT -1
SALES AREA
100
P
TUKWILA FIRE DEPARTMENT
Please call 205-575-4407 and
give this Fire. Perris N0:'
_43-S- 0'1,5 -
and exact address for shut-
down
hutdown or restoration ap ;rova.
DISPLAY WINDOW
100E
13'-6" - PT -1
I _ . 1[h
RETAINER STRAP WHERE REQUIRED
IN SEISMIC AREAS
TOP BEAM/ C -CLAMP
WITH SET SCREW
3/8' ALL THREAD ROD
PIPE SWIVEL. RING
I l�111131F!li1g331ilSilN;lff
iiNl:3t#iNt3l37i31
' - STAGGER LIGHTS AT
CORNERS, TYP. (6" MAX
BLANK SPOT)
STOCK ROOM
104
_.ACT—EX
NOTE: SEE ELEC .DINGS
FOR ADDITIONAL
INFORMATION INCLUDING
LOCATION/QUANTITY OF
NIGHT_ LIGHTS, EMERGENCY
LIGHTS, ETC
—LINE OF MILLWORK LIGHT
• COVE SUSPENDED FROM
STRUCTURE ANA SECONDARY
FRAMING AB0!,.SEE
DETAIL 5/A4.0 FOR INFO
STEEL JOIST/TRUSS
HANGER DETAIL
NTS
Fihal acce02: rcr Ic r
The
Date: .1-3o-/3
to 19&d test and Inspection by,
NNi33MMNN M
PORTION OF GYP3D
GEILILING TO BE.
TO MATCH EXIST'
• II' -II°. A.F.F., V.I
LOVE .ULT RE
Design per NFPA 13, Ordinary Hazard, Group 2
All materials to be new, U.L. listed, and F.M. approved
All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means'
All heads to be at least 6' apart
• 24 — Relocate Reliable Model G5 Standard Response 165° Pendents 1/2 x '/2 (on Flexhead)
• 8 — Add Reliable Model G5 Standard Response 165° Pendents 1/2 x1/2
• E — Existing no change
PORTION OF GYP 6D
GE'L'LING TO BE NEN
TO MATCH EXISTING
® 1I' -II' A.F.F., V.I.F.
—i
DISPLAY WINDOW
10.0E
MALL LOCATION KEY PLAN
STORE LOCATION KEY PLAN
} I y
T�! GpDRt3,E PLAC.0
9rORE .9233
9R..= E9
1.C5eoo�xvr5D1RDt H'HALL
I
n.:r.v, nti vme
ARRROXI{..lt 171STMCZ TO
ReuC TOILET ROA, . 2W rr —
EXTEND DISPLAY WINDOW
GRID A5 REQUIRED
CRC.WN-
FIRE PROTECTION
INCORPORATED
P.Q. BOX 12113
MILL CREEK, WASHINGTON 98082-0113
PH. (425) 481-7569
The Children's Place
1061 Southcenter Mall
Tukwila, WA
PA1!
JAN 24
TUKWILA,.
DATE: 1 ,2.1 - 13
DRAWN:
SCALE:
7(113E
FIRE