Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 1067 SOUTHCENTER MALL - SANRIO / KUNG FU TEA - PERMITS AND PLANS
1067 SOUTHCENTER MALL ASSOCIATED PERMITS 18-F-102 08-F-375 08-S-302 KUNG FU TEA GUARDIAN SECURITY SYSTEMS SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** } King Co. Assessor's Tax No. t4 L CO\OM Site Address: 1D ) ' t,Z4ui% Y" (tA( V\ISuite Number: Floor: Tenant Name: V.L n -T-Lt C New Tenant? - Yes ❑ - No Property Owner's Name: ' i', }1 ( 1 (O 't \» Mailing Address: P ` bV `").DCA` -0 ` V- ( r` A CI O\ City State Zip CONTACT PERSON -if there are questions about the submittal. n Namez C, C( ( VROO Day Telephone(2O 1Q 75 Company Name: C UD iCa:ka.., e ax l 4cYS LL Mailing Address: City E-mail Address: . OA t ► trZ L. • • it M Fax Number: Contractor's City of Tukwila, NICET III number: Business License number: t Total number of new/relocated devices or sprinkler heads: 2 State Zip Valuation of Project (contractor's bid price): $ I 1 `c'1V L„U Scope of Work (please provide detailed information): Z."-k'(e CXb`tw\ l 11Uid‘4- c \ PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature:L Qt Print Nam C X Plan Permit App.doc Date: 14 Day Telephone(2a0) (P'1 3C5 4-C1 8/22/14 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Vanilla Box 1067 Southcenter Mall Permit No.: 08-S-302 Date: June 10, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • These conditions apply to any sprinkler piping exposed as necessary to accomplish the permitted scope of work. All references are NFPA 13, 2007 Edition. 8Gi f Summary Of Outflowing Devices1 Job Number: KS0407 Report Description: Ordinary Group II Actual Flow Minimum Flow K -Factor Pressure Device (gpm) (gpm) (K) (psi) c> Sprinkler 101 24.00 24.00 5.6 18.367 Sprinkler 102 24.01 24.00 5.6 18.390 Sprinkler 112 26.09 24.00 5.6 21.702 Sprinkler 111 25.57 24.00 5.6 20.848 Sprinkler 110 25.48 24.00 5.6 20.696 Sprinkler 107 25.16 24.00 5.6 20.183 Sprinkler 106 25.15 24.00 5.6 20.167 Sprinkler 105 25.06 24.00 5.6 20.022 Sprinkler 103 24.75 24.00 5.6 19.540 Sprinkler 109 25.35 24.00 5.6 20.485 Sprinkler 108 25.25 24.00 5.6 20.334 Sprinkler 104 24.94 24.00 5.6 19.838 c> Most Demanding Sprinkler Data • gi, © M.E.P.CAD, Inc. M AutoSPRINK® VR5 v5.2.6 06/03/2008 9:09:29AM Page 2 jaf Node Analysis Job Number: KS0407 Report Description: Ordinary Group II Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 16 14-6 E(2-0) 28.320 22 14-6 E(2-0) 28.353 23 14-6 E(2-0) 28.421 36 14-6 2P0(8-0) 28.766 37 14-6 2P0(8-01 28.657 38 14-6 2P0(8-0) 28.632 46 14-6 PO(5-0) 26.894 50 14-6 PO(5-0) 26.798 51 14-6 PO(5-0) 26.816 60 14-6 PO(5-0) 25.998 64 14-6 PO(5-0) 25.908 65 14-6 PO(5-0) 25.946 73 14-6 E(2-0) 25.813 77 14-6 E(2-0) 25.720 78 14-6 E(2-0) 25.761 123 13-2 fE(6-9%) 41.982 191 13-6 fE(6-91/2) 44.014 319 1-11 P0(26-4) 53.086 361 3-10% BFP(-4.500) 56.792 400 1-11 LtE(16-0) 53.105 101 12-0 Spr(-18.367) 18.367 24.00 102 12-0 Spr(-18.390) 18.390 24.01 112 12-0'h Spr(-21.702) 21.702 26.09 111 12-0Y Spr(-20.848) 20.848 25.57 110 12-0% ' Spr(-20.696) i 20.696 25.48 107 12-0% Spr(-20.183) 20.183. 25.16 106 12-0' Spr(-20.167L 20.1671 25.15 105 12-0% i Spr(-20.022) 20.022 25.06 103 ' 12-0'% SpLEI9.540) 19.540 24.75 109 12-0% Spr(-20.485) 20.485 25.351 108 12-0% Spr(-20.334) 20.334 25.25 104 12-0% Spr(-19.838) 19.838 24.94 1 -4-0 S 60.245 300.81 ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/03/2008 9:09:32AM Page 3 Ill Hydraulic Summary Job Number: KSO407 Report Description: Ordinary Group 11 Job Job Number KS0407 Design Engineer Adam Kanter Job Name Vanilla Shells 1067 State Certification/License Number WESTESF136QF Address 1 Southcenter Mall AHJ City of Tukwila Address 2 Job Site Southcenter Mall Cay Tukwila State Wa Zip Code 98188 Drawing Name FP-1-1067.cad System Remote Area(s) Most Demanding Spnnkler Data 5.6 K -Factor 24.00 at 18.367 Occupancy Ordinary Group it Hose Allowance At Source 250.00 Density 0.20gpm/ft2 Area of Application 828.84ft2 (Actual 828.84ft2) Additional Node Hose Supplies Flow(gpm) Number Of Sprinklers Calculated 12 Coverage Per Sprinkler . 120.00ft2 •' Total Hose Streams 250.00 4 II •r' \ / ` r , e f 1V f ,, v , System Flow Demand 300.81 Total Water Required (including Hose Allowance) 550.81 Maximum Pressure Unbalance In Loops 0.000_ Maximum VelocityAbove Ground 11.99 between nodes 36 and 46A1 Maximum Velocity Under Ground 1.14 between nodes 1 and 361 Volume capacity of Wet Pipes 2427.85ga1 Volume capacity of Dry Pipes4111.016 6.54ft' Supplies Hose Flow Static Residual @ Node ' (gpm) (psi) (psi) Flow (gpmj Available Total Demand (psi) (gpm) Required • Safety Margin (psi) (psi) 1 250.00 140.000 20.000 10900.00 ; 139.520 550.81 60.245 79.275 Contractor Contractor Number KS0407 Contact Name Adam Kantner ' Contact Title • Project Manager Contractor Name Western States Fire Protection Phone 425.881.0100 Extension Address 1 7102 180th Ave Ne, Suite A-105 FAX 485.736.9032 Address 2 E-mail . Crty Redmond State WA Zip Code 98052 Web -Site ©M.E.P.CAD, Inc. ig AutoSPRI N KO VR5 v5.2.6 06/03/2008 9:09:25AM Page 1 Hydraulic Analysis Job Number: KS0407 Report Description: Ordinary Group 11 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Length Summary Length Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Eq. Total ao Route 1 DR 1.049 0=24.00 8.91 C=120 0.182334 50-5% Pf 11.027 101 12-0 q=24.00 K=5.6 18.367 Spr(-18.367) 10-0 Pe -1.075 16 14-6 28.320 5E(2-0) 60-5% Pv BL 1.610 0=24.00 3.78 C=120 0.022636 5-9% Pf 0.312 16 14-6 28.320 8-0 Pe 38 14-6 28.632 PO(8-0) 13-9% Pv CM 4.260 0=98.86 2.23 C=120 0.002718 9-0 Pf 0.024 38 14-6 28.632 Pe 37 14-6 28.657 9-0 Pv CM 4.260 0=198.66 4.47 C=120 0.009884 11-0 Pf 0.109 37 14-6 28.657 1 Pe 36 14-6 28.766 11-0 Pv CM 4.260 0=300.81 6.77 C=120 0.021294 352-4% Pf 12.638 36 14-6 28.766 100-3 Pe 0.578 123 13-2 41.982 2P0(26-4), 7fE(6-9%), 452-7% Pv 2cplg(-1.500) CM 4.026 0=300.81 7.58 C=120 0.028038 58-10 Pf 2.176 123 13-2 41.982 18-9% Pe -0.145 191 13-6 . 44.014 2EE(4-0), Eel (4-0), fE(6-9%) 77-7%z Pv CM 4.260 0=300.81 6.77 C=120 0.021294 112-0% Pf 4.054 191 13-6 44.014 78-4 Pe 5.018 319 1-11 53.086 3fE(6-9Yz), CV(28-11 %), GV(2-7%), 190-4% Pv P0(26-4) FM 8.329 Q=300.81 1.77 C=120 0.000813 7-7Pf 0.019 319 1-11 53.086 16-0 Pe -0.000 400 1-11 53.105 LtE(16-0) 23-7 Pv FM 10.420 0=300.81 1.13 C=120 0.000273 26-5% Pf 4.530 400 1-11 53.10583-0 Pe -0.842 361 3-10Y2 56.792 4LtE(16-0), BV(19-0), BFP(-4.500) 109-5%Pv UG 10.400 0=300.81 1.14 C=140 0.000207 109-2 Pf 0.046 361 3-10% 56.792 111-7 Pe 3.407 1 -4-0 60.245 E(35-1), 3LtE(25-6), S 220-9%zPv Route 2 DR 1.049 0=24.01 8.91 C=120 0.182539 50-6 Pf 11.041 102 12-0 q=24.01 K=5.6 18.390 Spr(-18.390) 10-0 Pe -1.078 22 14-6 28.353 5E(2-0) 60-6 Pv BL 1.610 Q=24.01 3.78 C=120 0.022662 5-5 Pf 0.304 22 14-6 28.353 8-0 Pe 37 14-6 28.657 P0(8-0) 13-5 Pv Gil Route 3 DR 1.049 Q=24.75 9.19 C=120 0.193080 27-8% Pf 7.474 103 12-0Y2 q=24.75 K=5.6 19.540 Spr(-19.540) 11-0 Pe -1.069 65 14-6 25.946 3E(2-0), PO(5-0) 38-8Yz Pv BL 1.610 0=49.70 7.83 C=120 0.087021 10-0 Pf 0.870 65 14-6 25.946 Pe 51 14-6 26.816 10-0 Pv BL 1.610 0=74.86 11.80 C=120 0.185663 1-9% Pf 1.816 51 14-6 26.816 8-0 Pe 38 14-6 28.632 P0(8-0) 9-9Yz Pv 4 Route 4 DR 1.049 0=24.94 9.26 C=120 0.195801 27-8% Pf 6.992 104 12-0% q=24.94 K=5.6 19.838 Spr(-19.838) 8-0 Pe -1.069 78 14-6 25.761 4E(2-0) 35-8% Pv BL 1.610 0=24.94 3.93 C=120 0.024308 7-7 Pf 0.184 78 14-6 25.761 Pe 65 14-6 25.946 7-7 Pv o Route 5 DR 1.049 0=25.06 9.30 C=120 0.197477 26-2% Pf 6.955 105 12-0% q=25.06 K=5.6 20.022 Spr(-20.022) 9-0, Pe -1.069 64 14-6 25.908 2E(2-0), P0(5-0) 35-2Yz Pv BL 1.610 0=50.31 7.93 C=120 0.089016 10-0 Pf 0.890 64 14-6 25.908 Pe 50 14-6 26.798 10-0 Pv BL 1.610 Q=75.79 11.94 C=120 0.189954 1-9% Pf 1.858 50 14-6 26.798 8-0 Pe 37 14-6 28.657 PO(8-0) 9-9Yz Pv Route 6 DR 1.049 0=25.15 9.34 C=120 0.198798 25-8% Pf 6.900 106 12-0% q=25.15 K=5.6 20.167 Spr(-20.167) 9-0 Pe -1.069 60 14-6 25.998 2E(2-0), PO(5-0) 34-8% Pv t ©M.E.P.CAD, Inc. 4 AutoSPRINK® VR5 v5.2.6 06/03/2008 9:09:36AM Page 4 111 Hydraulic Analysis Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Pt Friction Loss Pn Fittings Length Pressure Eq. Length Summary Total Length Downstream Elevation Discharge K -Factor Upstream BL 1.610 Q=50.49 7.96 0=120 0.089621 10-0 Pf 0.896 Pe -0.000 10-0 Pv 60 14-6 46 14-6 25.998 26.894 BL 1.610 Q=76.06 11.99 0=120 0.191244 1-9'/2 Pf 1.871 46 14-6 36 14-6 26.894 28.766 P0(8-0) 8-0 Pe 9-9% Pv a. Route 7 DR 1.049 0=25.16 9.34 0=120 0.198950 27-8% Pf 7.701 11-0 Pe -1.069 38-8% Pv 107 12-0% q=25.16 K=5.6 51 14-6 20.183 26.816 Spr(-20.183) 3E(2-0), P0(5-0) Route 8 DR 1.049 Q=25.25 9.37 C=120 0.200324 26-21,4 Pf 6.455 108 12-0% q=25.25 K=5.6 77 14-6 20.334 25.720 Spr(-20.334) 3E(2-0) 6-0 Pe -1.069 32-2% Pv BL 1.610 Q=25.25 3.98 C=120 0.024869 7-7 Pf 0.188 77 14-6 64 14-6 25.720 25.908 Pe 7-7 Pv .iw Route 9 DR 1.049 Q=25.35 9.41 C=120 0.201703 25-8% Pf 6.396 6-0 Pe -1.069 31-81,4Pv 109 12-0% q=25.35 K=5.6 73 14-6 20.485 25.813 Spr(-20.485) 3E(2-0) BL 1.610 0=25.35 3.99 C=120 0.025041 7-5 Pf 0.186 73 14-6 60 14-6 25.813 25.998 Pe 7-5 Pv Route 10 DR 1.049 Q=25.48 9.46 0=120 0.203617 26-2% Pf 7.172 9-0 Pe -1.069 35-2% Pv 110 12-0% q=25.48 K=5.6 50 14-6 20.696 26.798 Spr(-20.696) 2E(2-0), PO(5-0) Route 11 DR 1.049 0=25.57 9.49 C=120 0.205000 25-8% Pf 7.116 9-0 Pe -1.069 34-8'% Pv 111 12-0% q=25.57 K=5.6 46 14-6 20.848 26.894 Spr(-20.848) 2E(2-0), PO(5-0) wh Route 12 DR 1.049 0=26.09 9.68 0=120 0.212757 28-7% Pf 7.789 8-0 Pe -1.069 36-7'/z Pv 112 12-0% q=26.09 K=5.6 23 14-6 21.702 28.421 Spr(-21.702) 4E(2-0) BL 1.610 0=26.09 4.11 C=120 0.026413 5-0% Pf 0.344 8-0 Pe 13-0% Pv 23 14-6 36 14-6 28.421 28.766 P0(8-0) Equivalent Pipe Lengths of Valves and Fittings (C=120 only) C Value Multiplier Actual Inside Diameter 4.87 ) Value Of C 100 Multiplying Factor 0.713 130 1.16 140 150 1.33 1.51 = Factor ( Schedule 40 Steel Pipe Inside Diameter ©M.E.P.CAD, Inc. ±� AutoSPRINK®VR5 v5.2.6 06/03/2008 9:09:36AM Page 5 1 Hydraulic Analysis Job Number: KS0407 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Elevation Upstream Discharge K -Factor Pt Pn Fittings Length Pressure Eq. Length Summary ! Total Length Pipe Type Legend Units Legend Fittings Legend AO BL CM DN DR DY FM FR MS OR RN SP ST UG Arm -Over Branch Line Cross Main Drain Drop Dynamic Feed Main Feed Riser Miscellaneous Outrigger Riser Nipple Sprig Stand Pipe Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11Y<° Elbow Ee2 22W Elbow f Flow Device FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap (c, ©M.E.P.CAD, Inc. tj AutoSPRINK®VR5 v5.2.6 06/03/2008 9:09:36AM Page 6 II f Hydraulic Graph 1 Job Number: KS0407 Report Description: Ordinary Group II Supply at Node 1 150 Static Pressure 140.000 135 120 105 90 a J75 - 550.81 with hose streams 60 —300.81 @ 60.245 45 —System demand curve 30 — 10900.00 @ 20.000_ 15 7 11111.111111111 I I 11111 11 11 1 1 1 1 1 I 1 1 1 1 Li Li 1 1 1 I I I 1 1 1 1 1 1 1 1 11 1 L_L L 1 1 1 1 1 L 1 L 1 I A 1 I_ L I 1 1 1 111111111 0 71002200 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 © 20.000 Available PressureTlme of Test 139.520 @ 550.81 System Demand 300.81 © 60.245 System Demand (Including Hose Allowance) 550.81 @ 60.245 ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 06/03/2008 9:09:45AM Page 7 Flow Diagram (Top View) Job Number: KS0407 Report Description: Ordinary Group 11 ©M.E.P.CAD, Inc. 4,fiAutoSPRINK®VR5 v5.2.6 06/03/2008 9:09:49AM Page 8 FIRE ALARM SYSTEM ADDITI N TUKWILA, WASHINGTON SHEET \UM3ESHEET TITLE FA -01 SYSTE Vi I\FOvATION FA -02 TYPICAL WI SING A\D v OUNTING DETAILS FA -03 SYSTEv CALCULATIONS A \D SINGLE LINE DIAL AM FA -04 FRE ALA SYSTEM PLA\ SHEET INDEX CCE Without Comments D As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted izndards and ordinances. The responsibility for the .d ;qwcy of design rests totally with the designer. ;editions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau, IBy; ~ J ,_-a-,,--,-r:-:. WISE SCH TUKWILA FIRE DEPARTMENT Pease call 206-575-4407 and give this Fire Permit No. I -F- IcD ::nd exgc.irs for shut- 4i:Ar4n C9' r,....orstion approval. DUL AND CO\ D U IT FILL CHAT WIRE DESIGNATIIN SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FiRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDAT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY 1 1 E E E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW SIEMENS 4S BOX CEILING HT -R INTERFACE MODULE WITH RELAY (NEW) HTRI-R SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE ®D DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM E DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R E INTERFACE MODULE WITH RELAY (EXISTING) HTRI-R SIEMENS 4S BOX VERIFY IN FIELD 8E FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -CW SIEMENS 4S BOX CEILING EI TENANT J -BOX F.B.O. F.B.O. VERIFY iN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N /A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A fNi/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND 1, NORDSTROM 3 LEVELS : 1.275sr • SEARS C macys .x KUNGFU TEA 1067 J m,4. W e.:; rK. 1-1- z . R. w 900 PAID [IA( --2 201C TUKWILA FIRE SITE PLAN ce_ aD 0' 0' 0' 0 N LL RELEASE/REVISIONS 0 DESCRIPTION SHOP DRAWINGS LU 0 0 0 Zco co O < 0 z Q 0 1-0 w zz (5 ' m Q Z °C o J CD CC Li_ l- 1 CALE: NOT TO SCALE ' DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 05/01 / 18 BACKROUND PLAN PROVIDED BY: \ 0B NUMBER: 3417 i -12 , SHEET Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved \FA THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ DEDICATED EMERGENCY FROM EXISTING MAIN FACP C CABLE C' CABLE (—) 0 77 u OD N L 0 0 PAD -3 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - B 0 a O O Q LIZ (+) (—) (+) HARD LID CEILING HARD LID —\ SPEAKER SUPPORT TILE BRIDGE NAC S4 NAC S3 22 NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) 6 ) ) STROBE SPEAKER (+) (-) FROM PREVIOUS ADDRESSABLE 2 DEVICE HFP-11 TBI 0®®®®0 ®o NO COM NC EOLR 470 SWITCH + - INPUT LED TSM -1 00 00 TO FAN SHUTDOWN TO NEXT ADDRESSABLE DEVICE 0 NO B COM B /ill HTRI-R "Ce °/L TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL T1 (+) (-) STROBE (+) ) STROBE SPEAKER SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE r O 1'0 v. c co C\J O o cv Q LL Lu w _O w 1743 IST AVE. CV W U) z 0 U) W c W LU Lk! REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 03 0 LC 0 2 a<<a Z _co Q0) Q In 0 O 2 I-0 Dwzz LL J _ 2".S o -- LL F- ‘!..1 w 0 0 z 0 z EI 0 CALE: NOT TO SCHLE: DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 05/01 /1 8 BACKROUND PLAN PROVIDED BY: \OB NUMBER:3417 -1} Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET \ FA -02 Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps A B C D E F G H 1 J K FIRE ALARM BOOSTER Project: KUNGFU TEA Panel: EXISTING BPS PAD -3 Date: May 1, 2018 Module/Device POWER REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 2205 oaa Total(A)= 15 Total(B)= 2345 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 2345 Total current ratings converted to amperes (line D x .001) 0.015 2.345 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.1953385 Add lines G and I Total Standby and Alarm AH 0.5553385 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.6664062 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 CALCULATIONS Notification Appliance Circuit Detail PROJECT: °KUNGFU TEA Panel:: EXISTING BPS PAD -3 REMOTE POWER SUPPL Date: May 1, 2018 • 4 SET -MC -CW @15cd 2 . i C' SET -MC -CW @30cd SET -MC -CW @75cd SET -MC -CW @95cd 3 E ZR -MC -CW @15cd DEVICES Wire Resistance 2.58 CURRENT TOTAL= 2205.00 69 276 111 222 200 0 264 0 .. 69 207 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 705 14 218 23.21 (WL* 2 )*(Rift) (Total Cct Load) (E_I*R) 24-E) 705 1.12 0.71 0.79 SET -MC -CW 015cd SET -MC -CW @30cd SET -MC -CW ©75cd SET -MC -CW @95cd ZR -MC -CW @15cd DEVICES MAXIMUM LOAD 69 111 200 264 69 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 0 0 0 0 1500 14 24.00 (WL *2) * (R/ft) (Tota I Cct Load) ) (Err. 1*R) 24-E) 1500 0.00 1.50 0.00 24.00 * NOTE: 1 -NEW SPEAKER/STROBE + 1 -EXISTING SPEAKER/STROBE TO EXISTING SPEAKER , CIRCUIT TO OTHER EXISTING NAC DEVICES ( CIRCUIT S1) TO EXISTING DATA LOOP 2V b 2S b S,V SbV 51-5 30Cd (TENANT J -BOX) SINGLE LINE DIAGRAM 1 HT -R 21-0 TSM S,V b S1-6 30Cd HT -R FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved Eliftg N) co 0 ON co N .rte' N L RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 05/01/18 oaa CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:05/01 /18 BACKROUND PLAN PROVIDED BY: '0B NUMBER:3417 1 — 1 SHEET f 3 FA-0 ' RAT=D iA TING AR FA 0NC NTPATI- D ,:-AT v AREA. S1-5 30Cd ORD -R S,V E Ji. L_ T I1I ojo Iti E I TSM Di i D HT -R I -- — I - — / / / I I S,V \ I t ' : E! t' tt !: !i II !! Ee I! II IE II !i € ! I€ Fi. t E eiI III IE II ti II iI I tl Ii i! I II Ii 1! t! II 1! 11 i 11 I. Et I Ei i ! !! i GI 1 I i i II 'I t II It ( l? _ II t3 I II -I e1 II It ! 1 I i IE I! 1 ' I !I 1 I II I iI Il ii 11 t1 H ii II el II II r'I 11 H I_I !. I 1! : I I ii Ei !E EI II i! II ! II i! I i ! !I I II 1 1! II :F !I i !t Ti EI I it tI I EE1 F ! tI II ! !1 E II II II Ii 11 €i II F( ! i II !I !I. I D HT -R S1-6 30Cd i lli tel F—u l< I I!li if !I c- D »ill II If Ii to i 11 H ;1 II r e! 1 f+ it 17 Iii 0 O TO TENANT J -BOX TO TENANT J -BOX FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 0 SEATTLE, WASHINGTON 1743 IST AVE. SO., TEL. (206) 622-654L RELEASE/REVISIONS IREV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE QD 0 0 0 <<<< 0 co Wil T OFozi R. cos W o 0 <2 HO wH Dwzz 1_ (/) Z C 2 O _1 J < N.. — mow"' O Y `.`_ w Usa SCALE: 1/2' =1 '0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 05/01 /1 8 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 34171 —1; SHEET FA -04 WESTFIELD SUITE 1067 FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND ........ .... :..= FA 01 SYSTEM I F RMAVION FA -02 • •Yo NG AND MOUNTING FA 03 FIRE ALARM SYS -EM F 00R PLAN FA -04 SYSTEM CALL U LSAT ONS (C-ENERAL)., RISER, , SITE ?LAN WIRE DES DESIGNATION SCHEDULE WIRE. SCHEDULE AND CONDUIT HU_ L CHART VIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE s V X UD tel. M DATA LINE --ADDRESSABLE LOOP IR HOLDER PI:IWE:R 24VDC DEVICE POWER 24VDC STRODE CIRCUIT - FEED ANNUNCIATOR SPEAKER CIRCUIT - FEED REMOTE INDICA TION LIGHT LOW Ti i LE ,Ati SL AUDIO UNDERGROUND DATA UNDERGROUND IN! T €ATIO DOOR HOLDER POWER I#E:AE4 1)E•::TECTOR POWER TWISTED PAIR WITH SHIELD #I6 FPL/FPLR RED (.JACKET) Two 1114 FPL/FPLR RED <JACKE:T) TWO 416 EPLJF PLR RED (JACKET) TWISsr.n PAIR W? SHIELD w12 FPL/FPLR RED <JACK.E D TWISTED PAIR W/ SHIELD #16 FPL/FPLR P: R RED (JACKET) TWIST ED PAIR 444 FPL/FPLR RED (JACKET) EWES TWISTED PAIR W/ SHIELD TWISTED PAIR RATED TVTS.TE.EI PAIR RATED TWO TWO *48FPL/FPLR REB (JACKET ) 446 FPL/FPLR RED (JACKET) s1S FPL/FPLR RED (JACKET) *i6 EPL/FPLR RE (JACKET T ) *16 FPL/F'PLR REB (JACKET) II14 FPL/FPLR RE:I3 <JAi',E.'.E'T> CONDUIT FILL CHART ND. OF CONDUCTORS VOLTS WIR SIZE TWO TWO TWO CONDUCTOR 600V #12 AW 600V #14 AWG 300V 418 AWG TYPE DIMENSIONS AREA T1•II•lidITE-iiPd .244 J.G. .0467 TEE€-€N/IHWN TWISTED .210 0.0. .0346 FPL TW CR13LE .15€5 0.0. .0191 CONOUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONOJir FROM THE TABLE ABOVE_ CHOOSE THE SIDE OF CONDUIT BASED ON 1H.E. MAXIMUM }ILI. D!ME_NSI0N FTS0M THE TABLE BELOW THAT DOES NOT FXCE 1 D THE TOTAL AREA OF 1I -IE W1RE. CONDUEP 611E 1/2' 3/4" 1 2' AXI UM FILL .12 SQUARE INCH .21 SQUARE INCH .34 SQUARE INC:: ..0 SQUARE INCH .62 SQUARE INCE: 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDJrr Ha AND ARE TAKEN FROM N.E.C., CHP. 3, TA3LE 4. SHIE L ED WIRE TO BE GROUNDED AT PL NT OF E.'•.RIuIN PUNCHED THROUGH EACH DEVICE. WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEV CE SYMBOL DENOTE DEV CE CIRCUIT/ADDRESS DEV CE 01-1-02 WOULD BE IF E SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. 3. 4. S. EC; TOR AND AUDIBLE CIRCUM POLARITY SHALL BE OBSERVED, AUDIBLE/VISUA.. C RCUI I WIRING IS SUPERV SED. NO PARAL.I.EI.. BRANCHING IS PERMISS.B ..E INSTALLATION SHALL. BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NEPA 72, I..00AI.. CODE(S), AND/OR AUTHORITY HAVING JUR SDICT NSTALLATION MATERIALS (LE. CONDUIT, WIRE, EH IINCS, HANGERS, STANDARD BOXES, } BER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY S EMENS CERBERUS D V SION. 6. DETECTORS S"TALL NO • BE MOUNTED IN DIRECT AIR STREAM OE AIR SUPPLY OU II..I:.IS. PER NEPA 72 2-3,5.1 ON. 7. WIRING SHA A.. BE PER PLAN WI- H RESPECT TO CONDUCTOR SIZE, & OR CABI..E TRAY, TYPE, QUANTITY AND COLOR CODE. . CONI)UC V ORS SHALL L BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 'STALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURA ILLY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADD I TIO' AL NS- ALLA ;ION INSTRUCTIONS, REFER TO CATALOG ALOG CU SHEETS AN[) /OR INSTALLATION INSTRUCTIONS. THE. 12Ovoc POWER ELECTRICAL. WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMP ..Y WIH AR -10..E 725 AN) 760 OF NEPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5,2: IN RD-ERENCE TO DEDICATED BRANCH POWER SOURCES. 120voc POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE:. ALARM .TT::CI-IN CIAN, ALL HORN/STROBE AND S II4OBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEI..ING, WHICHEVER IS LESS. A _L_ MANUAL PULL STATIONS SHALL BE MOUNTED AT 48„ A.F.F. TO HE ACTIVATION DEVICE. ALL PANEL NUMBERS AND C RCUITS WILL BE ON THE RECORD DRAWINGS SET. A..1.. 12OVAC CIRCUIrS ARE FROM DEDICATED C GENERATOR. PER NFPA _72 SECTION 5----3.6,1,3 DETECTORS SHALL NOT _BE INSTALLED UNT THE CONSTRUCTION CLEAN-UP OF ALL WADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQU RED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONS I RUCTION. DE I ECTO RS THAT HAVE BEEN INSTALLED PRIOR TO F NAL CLEAN-UP BY ALI TRADES SHALL BE CLEANED OR REPLACED N ACCORDANCE VIIITH NFPA 72 CHAFER 7, RCUITS FROM THE EMERGENCY 16. WRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEV CE WITHOUT SPLICING IN PULL BOXES OR OTT }ER BACK BOXES Off. DIFFERENT C RCUITS. L AFTER 17. ALL Isk R NG SHALL BE MEI FRED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE 0F S -10ffIS BETWEEN CONDUCTORS AND 0. HER CIRCUITS PRIOR To F=INAL. EQUIPMENT TRIM, 18. AI..L. CABLES SHA..L. BE. MARKED AS INDICATED ON FIRL.. ALARM RISER V1/111i A PERMANENT l..ArB}:I.. AT Al..'.. t)E:.V CES, JUNCTION BOXES AND >- ACP. 19, THE:: ELECTRICAL CONTRACTOR SHA..L.. CLEAN AU.. DIRT AN:J DEBRIS( FROM HE OUTSDE AND NSI1.)E OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPI..F: T ON OF THEIR IR INSTAL.I..A TION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE E.NYRONMEN T IN WHICH .. IS 1..00A"::.1.). 21. ALL WIR NG BETWEEN FLOORS SHALL BE LOCATED N CONDUIT. 22. NEPA 72 2007 6.4,2.2.2 ALL STYLES OF CLASS A C RCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGO NG AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CON II#0L UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. -HE OUTGO NG AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL. NOT. BE RUN IN THE SAME CABLE ASSEMBL.Y MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 S TO PROVIDE ADEQUATE SEPARATION BETWEEN TETE OUTGOING AND RETURN CABLES, THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OE THE CAB: ->_S 1 ROM PHYSICA.. )AMAGI:..THE : R ::COMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTAL..ED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 1 2 0 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PAN El XLS ---V SIEMENS PROVIDED 55" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP 1 BPS REMOTE BOOSTER EX POWER SIJP = I PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP •E] INTERFACE MODULE WITH RELAY HTR I -R SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODUI HTRI.... D SIEMENS 4S DEEP VERIFY IN FIELD CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 45 DEEP VERIFY IN FIELD LINEAR BEAM SMOKE DETECTOR PBA ---1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HF P--1 1 `V SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING f ® DUCT SMOKE DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD FET DETECTOR (ADDRESSABLE) HF Pr -11 `d/ SIEMENS DB -11 BASE 45 DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE _._ (CEILING MOUNT) FIREALARM SPEAKER STROBE (WALL MOUNT) SET -MC -CW SIEMENS 45 DEEP BOX CEILING W/ 1....1/2" EXT. SET -MC -W SIEMENS 45 DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. 10 BOTTOM FIRE ALARM SPEAKER STROBE (WALL. MOUNT) SET -HMC -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING FIRE ALARM STROBE CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 45 BOX W/ 1G RING BD" A.F.F. TO BOTTOM U.O.N. FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 45 DEEP BOX w/ 1-1/2" EXT. CEILING FIRE ALARM SPEAKER (WALL MOUNT) SE.......W SIEMENS 45 DEEP BOX w/ 1-1/2" EXT. BO" TO BOTTOM FIRE ALARM I STROBE '' P (WEATHERPROOF) MULTI -VOLTAGE CONTROL R .LAY SET -S17 -WP SIEMENS MT -SUR -BOX 1 /2" PIPE VERIFY IN FIELD MR -201/C AIR PRODUCT'S 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.C. VERIFY IN FIELD FIRE ALARM TERMINAL CABINET F. B.O. F.B4O. F. B.O. VERIFY IN FIELD O JUNC'T'ION BOX F.B,3, F,B,D, N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED: FLOOR F.B.D.FURNISH OTHERS ED BY N/A U.D,N, NOT APPLICABLE UNLESS OTHERWISE NOTED N/A N/A N/A N/A N/A N/A N/A WithoutComments ° lVs"iA As Noted I ......-...-....-__-. _._.-...N/A 0 Per The Attached Letter ♦. vP REB WEATHERPROOF DE\'ICE AS BUILT ADD £R CHANE N/A ittigeqplans have been revit46d by The Tukwila Firel/A Prevention Bureau for conformance with current city -e rsattrt- - 'sta77d8TC1s:"'}'iZrc ""ptc3fTc2 -is-- iia r„fitt7 rra N/A ortIsVons which do not autliviAe violations of adopt'A standards and ordinances. The responsibility for the adequate -of desired witli the designer. GREENAS BLITI..'l N/A REMOVE BLUE AS BUILT NOTES TO CAD Actilffi6ns, deletions or revistM6to these drawings afitbVA this date will void this_acceptance and will require a resubmittal ofirevvssen dra irri '1ur'stitis'eg erit'approvat N/A N/A N/A N/A Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau Date: 4 a By: 06) TUKWILA FIRE DEPARTMEM Piease call: 575-440Z - and give this job tVo.® and exact address for shut* ,,wry or restoration approva!J 7 co 0• CD 0' 00 c) J W : 0 Lai tfr z SHOP DRA E.i., 1z. 0 co c in O EI 41-1 <zi NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presentee to ti ie Inspector prior to commencement of Acceptance Testing of any Fire Alarm 0 and Detection Systems. ,' Failure of test will result in a Rntd SCALE: 1/8"=1' terminatione-ispecof the ion Fee testingan N. 0 w W 5 CI) 1E A w< L cc w CO Cr 0 Wiz_ M CO 5 H 0 0 z V. (1, Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 BACKROUND PLAN PROVIDED 9Y: \1/2,19B NUMBER: r SHEET FA -01 J THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT we. SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE 0 FROM XLS CONTROL PANEL OR I PREVIOUS ADDRESSABLE DEVIC END OF LINE DEVICE(3.6K 1/4W) 5 T 0 L SUPERVISED SWITCH GROUND—' NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 0 HTRI—R OSTATUS LED t` to 0 0 0 DUCT DETECTOR LOCATI❑N N.0 COM N.C. © TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL IMF LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE•... DEVICE TO NEXT ADDR}:SSABLE: DE:VICE:: .{. VOLTAGE MAX: - CURRENT MAX: -- CONT. RES, MAX,- AX, CABLE LENGTH - C (LINE TO LNE)- C (LINE TO SHIT: LD) - MAX, LINE SIZE -- MIN, LINE SIZE- NOTE IZE- NOTE 2; OUTLET SAMPLIN €UDE: INLET SAMPLING TUBE AT I vAsT SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE MUSIC AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE f STOP IF LAST DEVICE .r) PREVIOUS FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE (-) RELAY CONTACTS (4.0A @ 125VAC) (4.OA @ 30VDC) 27 VDC 3,5 m DURING POLLING 10 OHMS 200 FT, (18 AWG) 0,021 F 0,O4uF 14 AWG 18 AWG ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTION, TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END OF LINE DEVICE (3.6K 1/4W) SUPERVISED SWITCH GROUND 1 0 0 ..0 0 0 HTRI—D OSTATUS LED 00 0 0 J NOT USED (0 0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. v TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL U43EL scALE (FIRE SUPPRESSION SYSTEM INTERFACE) 2 0 r.:::E I 1L.' 3 0 E£i£°Ei7 c s'JF MIMIC NN 1 N.R12 ma NJ144 AUK 14-1— 1 24.2— 2 Nr O NO 9 — i — — 4 — 4 — I- I Ix > .-INOPI .IA'.Ilt:1l 11101 A < 4 1 :!:...J END OF LINE DEVICE 3.6K 1/4W) SUPERVISED SWITCH • NAC --4 NAC -3 NAC --1 FRONT VIEW NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP FROM XLS CONTROL PANEL OR (+)1,---. PREVIOUS ADDRESSABLE DEVICE (-)> O TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCA: NONE FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (V❑ICE CIRCUIT) ('V' CABLE) -_ (+)TO NEXT DEVICE OR `{-) STOP IF LAST DEVICE {+) (-) STROBE SPEAKER (+) (-) SPEAKERISTROBE AND STROBE WIRING LABEL SCALE e..E <ER GnOBE Cit S13 'OB£.: ONLY 00' Q.F.F. 4S DEEP BOX W/ 1...1 ler EXTENSION RING (SKIVER STTROM) 4S BOX (STR0E ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE - TO NEXT DEVICE OR - END OF LINE TO NEXT DEVICE OR END OF LINE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER 11N TEMPERA +32' F 0' C TO 100' F 38 C) HUMIDITY: -9 X RELATIVE HUMIDITY, NON -CONDENSING HW -11 SMOKE DETECTOR --- FROM PREVIOUS I TO NEXT DEVICE «- ADDRESSABLE DEVICE OR POWER SOURCE REAR VIEW DATA IN (-) I -(-) DATA OUT DATA IN (+) -.---+ DATA OUT DEVICE IS USTED FOR AIR VOLOaTY APPLICATIONS OF 300-4000 FT IN WHEN USED IN CONJUNCTION TH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABi SCALE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD 110) HARD LID === CEILING HARD LID SPEAKER SUPPORT BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE NONE JUNCTION BOX NOUN T:I) ON CEILING FLEX JUNCTI MOUNTED A CEILING 5 N BOX AIMS' PPGRT 0 SMOKE DETECTOR --- SMOKE DETECTOR MOUNTING SCALE=NONE 0 0. TO N -:XT DE:VICE: CADDY DAR £ SUSPENDED ILLUMINATED CEILING DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright _2006 by Guardian Security Systems, Inc. All Rights Reserved 1143 Ckt 40 00 0` 0 G v UJ Q €-LI (n £r) C3 • Li) (t1 CD (!) t\3 J LU Cr (T 00 C.) t..I LL. I.*) U) C) (1) LU UJ Lia 1.3.1 J H L) w Lu n CO 0 C:) N. 0 OD LTJ 55 z Wamens—.. ITO r ZZ Ci C2C4 u_.L1712 w w 0 • CD z CD cf) z 0- 0 z z E 1 'ALE1 /858=1 s DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 BACKROUND PIAN PROVIDED BY 0B NUMBER: 17 SHEET FA -02 0 15 S. Lvi .24" ;r...."Z•P f 2S2.3,PV ,2s/ f 33 I - • 2-3,21/ NORTH SUITE 13ya WESTFIELD SOUTHCENTER MALL SCALE 118°4 ( '.../ 3.\-"" \ \ / \ • i i : / ; .." •2 •••• \ .. i ‘.. - --.... ..,' ••••-•. ..... ,"' FLAG NOTES FIELD LOCATE. RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS Bum - DETECTOR ON RETURN SIDE OF ALL VAV UNITS.<SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR, SIEMENS HTRI-D ADDRESSABLE INPUT WITH HOOD VENILLATOR FIRE SUPPRESION SYSTEM, FIELD LOCATE WtTHIN 3 FEE.:T OF CONTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT, DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. o. ht 2006 b Guardian Securit S stems, Inc. All Ri his Reserved FAX (206) 628-4990 <<1 (SCALE: 1/8" =1' DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 BACKIWUND PLAN PROVIDED BY JOB NUMBER: SHEET FA -03 • ; t . • • - - • • • . • • • • • • • • :.• .. .. '1 . .................. ::): i:::, :.• :.• :.• .. .. .. • • • • ........ .. ..... • • • • • .......... • • ........... •• ....: . . . . . . • .. :. : .• . . . . . . • • - .. . .. , .. :. SYSTEM CALCULATIONS BATTERY SIZING CALCULATION • • e NORTH SUITE 1067 WESTFIELD SOUTHCENTER MALL SCALE 11321=1' 3i) S,2V F S,2V S;2V S..2VS,2V S,2V n 2V 4i 11 15 15 15 15 1.5 ' FACP1 EX RISER DIAGRAM _! Notification Appliance Circuit Detail .___ ____i I PROJECT: rWESTFIELD SOU:CHCENTER MALL ' 1 , ....___________ r.....:..,,.........r..... _. , Panel:11067 '!Wire Resistance 1:1: : •- .6Z---•••••••••:: ..- •-... 1 • - i --- -- ••••••••• I ' ' , 1 Date: I May 29, 2008 CURRENT TOTAL1482 I CIRCUIT:1S1 QTY . i Device Type /Alarm Current11 Alarm Total 1 Wire Size Wire Length 1 Voltage at EOL 1 Circuit Total --F- i 1 i 1 , , ' ; t i t . 1 t t T t 5 1SET-MC @1 5CD i ; 641 320' ,• , Ii Total Wire Resistance ( R ) r 0.861 t 1 ISET-MC @30CD 1 981 98 1 ( WL * 2 ) * (R/ft) 0 SET -MC ©75CD 1 1 -I- , 1 1751 oi , , ..„..._...1 _r_ T_o_ta_l_p_e_vi_c_epsi.9_,___ _ p_. 481 i 0 - 1SET-MC ©110CD 4 ? r , 0 1 , ..,................ , 1 0 1SET-HMC-C@115CD 1 233-11._ 3181 01 I ; (Total Cct Load) _.t......_ ,o .._............1........_ 'Voltage Drop ( E ) 0.411 1-. - 0 01 Y (E= I * R) ISET-HMC-C©177CD i 4451 I ; _________________________________.... , t ; 0 i SET -HMC ©135CD f,. i _ ( 3181 01 1 I EOL Voltage f ! 1 9 . 991 , O 1 / ; 446954L11_ 0 Z-MC©30CD : 01 1 I t ; I ; 1 0 1SET-HMC ©185CD ; 01 , : i 1 1- (20.4 - E) 64 i 1 1Z-MC©15CD 1 0 SET-MC-CW@110CD 11,--- 01 ; 2331 1 482 i 12 .1 t ToTAE mA= 1 265 - 482 1 ; 19.98615481 1 , . --,--,--"------- - ,1• '''• -'•' • '•• • -•.,••••••,•••••••••••- -•.•.- .,-..-,••,,,,1,-t,+:•,,,,,--.%••wr,..-tassr.st•aas,...ntee..,..ate,,,x.or,-1,,,r.,,,o,,,,,,,....,-,ze•4,.,,-,.,,,,,,,,•, -,,,, ,,,,,,.....0.-,n4,,,,,,,,,,,,,,,,,.,.,,,,,,,,,,,,,,,,,,v,s,..c..."........,,a-,,...te,„,a,,,,,,,,,,,,,x,,,,,,n,,,,,,,yar . s.••••,,,,,,..- •^••., ..-.-•-,--s, --,,, ,..1",••••••••••-,.,• , , 1 ! i 1 Notification Appliance Circuit Detail { f 1 , I . ; PROJECT: il/VESTFIELD SOUTHCENTER MALL; ; 1 _....... ..„,„ . ..._.....__ .._._., Panel:11067 ; Date:1May 29, 2008 1 CURRENT TOTAL= I 10.8 CIRCUIT••i SPEAKER CIRCUIT i 1 ; , , QTY Device Type 1Alarm Current i Alarm Total I Wire Size Wire Length Voltage at EOL Circuit Total 1 1 ,....,... ....... ..., : r -1--- 6 170.7V1/8 ; • 1.81- 10.81 i 1Total Wire Resistance ( R 1.341 1 ; 01 01 ____________________-___ . i .,..._ , 0 I ( WL * 2 )* (R/ft) 0 i , i o 0 01 -.1 ,bTotal Device Load, Amps (I) 0.01 ! . 0 I _. ___........,....,.......______._ Oi 01 1 1 (Total Cct Load) i I. , , 0 I , , ' 01 01rVoltage Drop ( E ) ... _______ _........._________•1•___ i... 01 01 - ,... 1 1 (E= I * R) o.of .„. i i ! 01 1 EOL Voltage 20.391 I-- 0 _.,........ -/- - ... 0 1 ; ; 01 01 ; 1 i ! i i 0 i I -1- - 0! 1 ....___,..............._........__ ..._ i i 1 i i 1 ; b EVIC ES= i 6 TOTm A= i 1 0.8 1 14 . 1 260 ; 20.38551072 10.8 1 ;-- ; ----1 . , 'Wire Resistance _2.58 ......... VOLTAGE DROP CALCULATION Co. -ri.ht 2006 b Guardian Securif S slams, Inc. All Ri his Reserved FAX (206) 628-4990 ( cn 7- U) CD uJ ft uJ 5: uJ z 6.. 11.1 SHOP DRAWINGS -s? 0 0 CO 1 /8"= 1 s DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 RACKROLIND PLAN PROVIDED \\110B NUMBER: SHEET FA -04 1067 1067 SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations FACP ADD ONS Current Load: Standby: Alarm: Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 Main System Board 1 0.03 0.03 0.030 0.030 AD2-P - 1 0.0635 0.0635 0.064 0.064 SET -MC @15CD ---SEf-ICA6 @3666- SET -MC @75CD 5 0.064 0.320 1 1HTR-R 2 0.009600 0.0096 0.021 0.042 1 0.098 0.098 IIITRI-b ICP -B6 0.001600 0.0035 0.175 ' 0.005 SET -MC @110CD SET-Ftiio-o---6idb--- SET-HMC-C@135CD 0.233 1-- - 0.318 0.318 SET-HMC-C@185CD 0.445 0.0731 Amps 0.106 Amps ZR -MC @15CD 1 0.064 0.064 ZR -MC @i0613 0.098 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours Tel:; 0.0015 0.03 Amps 0.512 Amps Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours 25% Derating= 2.204 Amp -hours Alarm Current Load: 0.512 Amps For 5 Minutes= 0.043 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 0.954 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 0.954 Amp -hours 112VDC 1 Battery Pair to be Used: Amp -hours 7AH BATTERY SIZING CALCULATION • • e NORTH SUITE 1067 WESTFIELD SOUTHCENTER MALL SCALE 11321=1' 3i) S,2V F S,2V S;2V S..2VS,2V S,2V n 2V 4i 11 15 15 15 15 1.5 ' FACP1 EX RISER DIAGRAM _! Notification Appliance Circuit Detail .___ ____i I PROJECT: rWESTFIELD SOU:CHCENTER MALL ' 1 , ....___________ r.....:..,,.........r..... _. , Panel:11067 '!Wire Resistance 1:1: : •- .6Z---•••••••••:: ..- •-... 1 • - i --- -- ••••••••• I ' ' , 1 Date: I May 29, 2008 CURRENT TOTAL1482 I CIRCUIT:1S1 QTY . i Device Type /Alarm Current11 Alarm Total 1 Wire Size Wire Length 1 Voltage at EOL 1 Circuit Total --F- i 1 i 1 , , ' ; t i t . 1 t t T t 5 1SET-MC @1 5CD i ; 641 320' ,• , Ii Total Wire Resistance ( R ) r 0.861 t 1 ISET-MC @30CD 1 981 98 1 ( WL * 2 ) * (R/ft) 0 SET -MC ©75CD 1 1 -I- , 1 1751 oi , , ..„..._...1 _r_ T_o_ta_l_p_e_vi_c_epsi.9_,___ _ p_. 481 i 0 - 1SET-MC ©110CD 4 ? r , 0 1 , ..,................ , 1 0 1SET-HMC-C@115CD 1 233-11._ 3181 01 I ; (Total Cct Load) _.t......_ ,o .._............1........_ 'Voltage Drop ( E ) 0.411 1-. - 0 01 Y (E= I * R) ISET-HMC-C©177CD i 4451 I ; _________________________________.... , t ; 0 i SET -HMC ©135CD f,. i _ ( 3181 01 1 I EOL Voltage f ! 1 9 . 991 , O 1 / ; 446954L11_ 0 Z-MC©30CD : 01 1 I t ; I ; 1 0 1SET-HMC ©185CD ; 01 , : i 1 1- (20.4 - E) 64 i 1 1Z-MC©15CD 1 0 SET-MC-CW@110CD 11,--- 01 ; 2331 1 482 i 12 .1 t ToTAE mA= 1 265 - 482 1 ; 19.98615481 1 , . --,--,--"------- - ,1• '''• -'•' • '•• • -•.,••••••,•••••••••••- -•.•.- .,-..-,••,,,,1,-t,+:•,,,,,--.%••wr,..-tassr.st•aas,...ntee..,..ate,,,x.or,-1,,,r.,,,o,,,,,,,....,-,ze•4,.,,-,.,,,,,,,,•, -,,,, ,,,,,,.....0.-,n4,,,,,,,,,,,,,,,,,.,.,,,,,,,,,,,,,,,,,,v,s,..c..."........,,a-,,...te,„,a,,,,,,,,,,,,,x,,,,,,n,,,,,,,yar . s.••••,,,,,,..- •^••., ..-.-•-,--s, --,,, ,..1",••••••••••-,.,• , , 1 ! i 1 Notification Appliance Circuit Detail { f 1 , I . ; PROJECT: il/VESTFIELD SOUTHCENTER MALL; ; 1 _....... ..„,„ . ..._.....__ .._._., Panel:11067 ; Date:1May 29, 2008 1 CURRENT TOTAL= I 10.8 CIRCUIT••i SPEAKER CIRCUIT i 1 ; , , QTY Device Type 1Alarm Current i Alarm Total I Wire Size Wire Length Voltage at EOL Circuit Total 1 1 ,....,... ....... ..., : r -1--- 6 170.7V1/8 ; • 1.81- 10.81 i 1Total Wire Resistance ( R 1.341 1 ; 01 01 ____________________-___ . i .,..._ , 0 I ( WL * 2 )* (R/ft) 0 i , i o 0 01 -.1 ,bTotal Device Load, Amps (I) 0.01 ! . 0 I _. ___........,....,.......______._ Oi 01 1 1 (Total Cct Load) i I. , , 0 I , , ' 01 01rVoltage Drop ( E ) ... _______ _........._________•1•___ i... 01 01 - ,... 1 1 (E= I * R) o.of .„. i i ! 01 1 EOL Voltage 20.391 I-- 0 _.,........ -/- - ... 0 1 ; ; 01 01 ; 1 i ! i i 0 i I -1- - 0! 1 ....___,..............._........__ ..._ i i 1 i i 1 ; b EVIC ES= i 6 TOTm A= i 1 0.8 1 14 . 1 260 ; 20.38551072 10.8 1 ;-- ; ----1 . , 'Wire Resistance _2.58 ......... VOLTAGE DROP CALCULATION Co. -ri.ht 2006 b Guardian Securif S slams, Inc. All Ri his Reserved FAX (206) 628-4990 ( cn 7- U) CD uJ ft uJ 5: uJ z 6.. 11.1 SHOP DRAWINGS -s? 0 0 CO 1 /8"= 1 s DRAWN BY: E.HAMERSKI DESIGNED BY: R.VEZZANI DATE: 05/20/2008 RACKROLIND PLAN PROVIDED \\110B NUMBER: SHEET FA -04 • • N©tl cE Weld stamps I't`I u st' be inspected before pipe is hung. Da not paint pip 5-'g prior to hydrostatic test approval. 0 - Without Comments As Noted In Red E.' Per The. Attached Letter Shell Space 1067 VICINITY MAP (Suite# 1067) SCALE: NTS General Notes 1. Western States Fire Protection to add.new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand fiexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only jn the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. 1 nese plans have t:,?_;?.. -1 lr.:i:..,c; by The Tuk iia Fire Prevention Bur (;c:':...:rn„d, 41.? -,,,v7:,:71 cur; ;t cttu standards. Accar,i nc, i- !.,:.,..:.. , t,., t l rcr t- a.:.;d omissions 4v,oil d_.; I IL:,, ._ 1 :,. c,, .. •... : ;; . standards and cvr:,rl.._irl, 1116, r?‘:,1r.rit-,,i,;4,,r Jr1 °et; ',UI tnI: c_..:;,rl 'r. adequacy of cfe i ;rl r:; :i:: , }'L' ,', Additions, d'ifl tons -or. --:yis oils p; tri e: dlr:wir,,iF, :.;_,r this date will Void thki. ?cc'..}il3ri((-: 7,1r}d writ f °.l'.1i(.; ii resubmittal of revised d.rawlrigs for ub:;t (I1.;%:r it ,4 rO'VL1. Final acceptance is r.;ubject to fiofrt t'j t Gid irtspt otion by The Tukwila Fire Prevention Bureau. Date: (' ”-'0-- :-)S-' By: \` i , i i TUKWILA FIRE DEPARTMEN4 Please call: 575-4407 and give this job No. 0 -S :)- a-nd exact address for shut. :town or restoration approval. EAST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE SYMBOL LEGEND REVISIONS ZONE Main5 Ordinary Group ll•0.20gpm/ft2 for 828.84ft2 E F FIRE SPRINKLER SYSTEM 1 35 7 9 11 r • 118"=1'-0" TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE . FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL: NOT TO SCALE ////////,////// FIG. 008 SWIVEL SWAY BRACE FITTING 1M*EMBED LEEK N' BOLT BRACE PIPE FIG.1000 'FAST CLAMP' SWAY BRACE ATTACHMENT LINE PIPE LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE Remote Area 1067 SHELL SPACE CALCULATION DESIGN CRITERIA STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM / Ft' for 828.84 Ft' SPRINKLER Reliable F1FR Semi-Rec ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION': STATIC 140 RESIDUAL 20 FLOW 10900 PSI PSI GPM AT BASE OF RISER, SYSTEM REQUIRES: 300.81 GPM © 56.79 PSI ' At time of Design 12'- d" CLG. = 37.00% AREA REDUCTION FIG. 4A PIPE CLAMP FOR SWAY BRACE 3/9' KWIK BOLT (2 IW EMBED LENGTH) FIG.909 NO•THREADSWNEL SWAY BRACE ATTACHMENT LATERAL BRANCHLINE RESTRAINT twg0 NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III Rod Coupling — Q CME Rod Lgth Rounded to Nearest Inch AR Thread Rod Swivel Ring Concrete Construction Bottom of Concrete to Center Lege of Pipe Pipe Note on Plan r Note on Plan: HangerNumnber and 'A' Dimension HANGER DETAIL NOT TO SCALE FILE COPY Sprinkler Legend APPROVAL: 2 -WAY EARTHQUAKE BRACE 4 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K a 12 5.6 HYDRAULIC REFERENCE POINT Total = 12 Pendent1 Y2" Chrome SPRAY ORIF. FIN. 155°F TEMP. MFR./MODEL City of Tukwila CONT. NO.: KS0407 • HANGER SYMBOL BRANCHLINE RESTRAINT DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 06/03/08 VICINITY MAP DETAIL NOT 10 SCALE Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUCkIEROUVAUSTUUDALLAS / DECATUR /DENVER /DULUTH/ HOUSTON / KANSAS CITY LAS VEGAS IMEOEAPOUSIPHOEMXIPORTLAND IRAPID CITY/ ST. PAUL SALT LACE CRY/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 Vanilla Shells 1067 Southcenter Mali Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM • T•-••7 i! L. C3 Vanilla Shells 1067 w z 0 Adam Kantner ii CD 0 Swinerton Builders SHEET FP -1 OF 1 Tukwila Fire • Shell Space 1067 VICINITY MAP (Suite# 1067) SCALE: NTS General Notes 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. EAST RISER DETAIL HYDRAULIC REFERENCE ONLY 28 Remote Area 2E3 15'-0" A.F.F 12'-0" A.F.F i --Existing Main + ZONE T5 ® -■" ' Boa.. Ordinary Group II.0.20gpmfft2 for'828.84ft2 12'-0" A.F.F 2g 3c) NOT TO SCALE FIRE :SPRINKLER SYSTEM • G 3 5 7 9 11 TYPICAL FLEXAILE SPRINKLER CONNECTION FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXR EAD DETAIL NOT TO SCALE ////////////// FIG.909 SWIVEL SWAY BRACE FITTING 819' KWIK BOLT (2IW EMBED LENGTH) BRACE PIPE FIG.1000 "FAST CLAMP" SWAY BRACE ATTACHMENT LINE PIPE LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE Remote Area 1067 SHELL SPACE CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 occuPANcv CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 DENSITY .20 GPM / Ft' for 828.84 FN Ft' SPRINKLER Reliable F1 FR Semi-Rec ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION`: STATIC 140 RESIDUAL 20 FLOW 10900 PSI PSI GPM AT BASE OF RISER. SYSTEM REQUIRES: 300.81 GPM © 56.79 PSI At time of Design 12'- 0" CLG. = 37.00% AREA REDUCTION 3/8' KWIK BOLT (21N' EMBED LENGTH) ////////////// / / FIG.909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT FIG. 4A PIPE CLAMP FOR SWAY BRACE BRACE PIPE LATERAL BRANCHLINE RESTRAINT IA NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 070 HILTI Kwik Bolt III HILTI K"Bc Bok II Drilled Anchor i ( i Cut Rod Lgth Rounded to Nearest Inch Rod Coupling — AA Thread Rod Swivel Ring Concrete Construction q_ Bottom of Concrete to Center Line of Pipe PipeNote on Plan Note on Plan: Hanger Number and'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE e - S ' '2_ Vanilla Shells 1067 w z 0 Adam Kantner Swinerton Builders CONTRACTOR: SYMBOL LEGEND 2 -WAY EARTHQUAKE BRACE 4 -WAY EARTHQUAKE BRACE HYDRAULIC REFERENCE POINT HANGER SYMBOL NO. REVISIONS DESCRIPTION DATE Sprinkler Legend SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL BRANCHLINE RESTRAINT 12 Total = 12 5.6 Pendent Chrome 155°F APPROVAL: City of Tukwila CONT. NO.: KS0407 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 06/19/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBIAUER0UE /AUSTIN / DALLAS /DECATUR /DENVER/DULUTH/ HOUSTON /KANSAS CITY LAS VEGAS /MIM✓FAPOLIS /PHOENLX/ PORTLAND /RAPID CITY/ ST. PPM /SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax: 425.881-3030 Vanilla Shells 1067 Southcenter Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SHEET FP -1 OF 1