Loading...
HomeMy WebLinkAboutPP - 1071 SOUTHCENTER MALL - VANS INC - PERMITS AND PLANS1071 SOUTHCENTER MALL ASSOCIATED PERMITS 13-F-241 13-S-235 13-S-231 4401% SITE LOCATION Site Address: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** PI D S° cp26� 3 TUKWILA FIRE King Co. Assessor's Tax No.: 107/ 5 thC• k Medi Tenant Name: /7UVV P'k eS Property Owner's Name: Suite Number: Floor: New Tenant? ❑ - Yes 111- No Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name )toIrtx_ r ! l SL 1 Day Telephone: 4/ • yr1.76169 Crows Fe 3 chi Mailing Address: 'FV x 12\ \ rn 1 11 CP!'er , GOCZ E-mail Address: - & _.jA 1. 0m Fax Number: I/2 • 1#f • q Company Name: Total number of new/relocated devices or sprinkler heads: 5 7 Valuation of Project (contractor's bid price): $ 5 76-0 Scope of Work (please provide detailed information): PS64A. C57) Sir/ p I a fr PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: ei11167'� ? �+ Print Name: (,J 2 RO YA Date: r2 �3 Day Telephone: 4/24-- 4/07C06.7 Plan Permit App.doc 1/2/13 TFD FP Form 8 SITE LOCATION .4as CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address. Outhcenter Mali, Tukwila, 98188 Suite Number: space 408 Floor: Tenant Name: Maurices New Tenant? H- Yes ❑ - No Property owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City E-mail Address: Fax Number: 206 628.4990 State Zip Total number of new/relocated devices or sprinkler heads: l 1 jjj Valuation of Project (contractor's bid price). b® - Scope of Work (please provide detailed information): Adding 25 devices to existing FACP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 1 OR A;UTHORIZ D AGENT: Signature: I Date: - (2:1- Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Maurices 1071 Southcenter Mall Permit No.: 13-S-235 Date: October 2, 2013 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. 09/27/2013 11:48 4254818695 FAX TRANSMITTAL CROWN FIRE PACE 01/01 Fax No. CROWN FIRE PROTECTION, INC. 9.27.13 Fire Prevention Bureau Tukwila Fire Department / Al Demo Permit Number of Pages (including- Co. er) 1 0 Urgent E✓ For Review ❑ Please Comment 0 Please Reply 206.575.4439 From Czistie Ogland PH:425.481.7669 FX:425.481.8695 Comments Please provide a demo permit to remove (6) sprinkler heads out of the framing at the Maurcies project at 1011 Southcenter Mall. The building permit # is D13-260. Please let us know if you have any questions. Thanks— TUKWILA FIRE DEPARTMEIV7. Please call 206-575-4407 and give this Fire Permit No. s " 031 Ind exact address for shut town or restoration approval. P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8695 MALJRICES FIRE ALARM SYSTEM ADITION TUKWILA, WASHINGTON 0 .hese plans ha,,c :,',ention C�;r1:• ndards. ACc- sit .Tlards ;rev n: Iter Tukwila Fire current City "�• and adopted tht esuotriitti approval. 'final acceptai c- .1.210 test aid Inspection by NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing SHEET \U v 3ESHEET TITLE FA -01 SYSTE v I\F0� v ATO \ 8c S \GLE LINE DIAGA v FA -02 TYPICAL WI A\D VVO,\TI\G 3IAGAv S 8c CALCULATIO\S FA -03 FRE ALAS V PLA\ SHEET INDEX QUANTITY 1 1 2 6 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP ® SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM -_ - .-_TEST_ DUCT DETECTOR TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM DI HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM 13 HORN STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM JUNCTION ❑� BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS L EGEND WISE SCHEDULE A\D CO\DUIT FILL CHAT WIRE DESIGNATION DMG SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR` .RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS ' AREA TWO 600V #12 AWG THHN/THWN .244 0.D. , .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. C .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, \.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARv1 PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUVBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROv1 THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED NORDSTROM 3 LEVELS 171,275sf GEv�NESCO �,HL�� 0 MOM KYON IDODIVI� I AVON 1 rr Moue CORA. 8 PN0 &000 „f5,9OE tO1 macys 4 LEVELS 250,407st MAINS 00 11 oate:JO - 3 . 0,000 O1001NON TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. and exact I' {t - down or r'cs crit cri e; pprov3I. ut,CHO 0000100 1HE 1510 SKOP"- 5.1100 TO DO 11NDER 005 ,- MOWN 0055 NANI RECK IA THE. NAND. NCA I 100001AJt EI1 '1 L i1 50 6 10 8 OE_s1 Guy O01LE 9.,00 N COLD 41WEIS L 1 CA1CI7lTAWS10110 SS JOUR':EYS 0 91E1K SHOES SHEIK SHOES THE 000. 0 LIDS. 5500 PINION J0W0EE KING COUNTY 0ORARY 11.GWELERS50 00,1.0 0 11 EOISTIN JCPenney 3 LEYEL`: 276,468sf 010000 SIJHF MAURICES #2800 / SPACE #408 KEY PLAN TO NEAREST EXISTING SIGNALING CIRCUIT 2c 120VAC, DEDICATED (BY OTHERS) 1 4> - FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY FIELD MOUNTED NEXT TO EXISTING BOOSTER POWER SUPPLIES. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH. LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX IN BACKHOUSE CORRIDOR. S2-1 S2-2 S2-3 S2-4 S2-5 15cd 15cd 30cd 15cd 15cd S2-6 S2-7 S2-8 S2-9 S2-10 S2-11 15cd 15cd 15cd 15cd 15cd 15cd 2S J TO NEAREST EXISTING 2 DATA LOOP S1-1 S1-2 S1-3' S1-4 S1-5 95cd 15cd 15cd15cd 15cd D I HT -R D,I -� I HT -R1 2I` -c TSM S1-6 S1-7 S1-8 15cd 95cd 95cd EOL S1 EOL S2 PAID ", ?fl11 -z co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 1 \L. LL1-r,V L/ 1 \L V 1 1 N./ 1 VV NO I DATE I DESCRIPTION REV. BY: DMG DESIGNED BY: R. VEZZANI DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: 1 nm NIIIAARI'm. PAPP-1 SHOP DRAWINGS M N rn 0 <<<<< } 0 w U 00 Q� �rn w V2 QO 0 cf) EE = D g cc". Q Q2 1E2 �� u_ 0s- 0 0 CC Z 'UALL: NUT IO SCALL DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: 1 nm NIIIAARI'm. PAPP-1 • WIRE DESIGNATION GENERAL NOTES SINGLE LINE DIAGRAM 2227% Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -012 Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0:0022 0.0022 0.0023 0.002 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps R nal a'cu ;u Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CWc� 15CD 0.087 ZH-MC-CW @30CD 1 0.131 ZH-MC-tt11. Cc 75CD. 0.222 ZH-MC-CW @95CD 3 0.292 0.876 al -HMC -CW @135CD 0.371 ZR -MC -CW @15CD 0.069 ZR -MC- 15CD 13 0.064 0.832. 0.03 Amps 1.738 Amps Standby. Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm: Current Load: 1.738 Amps For 5 Minute 0.146 Amp -hours 25% Derating= 1.082 Amp -hours Total System Current Load: 1.082 Amp -hours Notification Appliance Circuit Detail PROJECT: MAURICES Panel: PAD -3 BPS Date: September 26, 2013 Wire Resistance 2.58 CURRENT TOTAL= 1977.00 -CW @15cd .M. `.... ZH-MC-GW_ ZH-MC-CW @75cd ZH-MC�CW @95cd.. ZH- MC -CW @135cd 2R -MC -W 15cd DEVICES 8 87 131. 222;~ - 292- 371 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E) Voltage 0 0 O j_.. 876 0 320- 1196] 14 255 22.43 1196 WL*2)*(Rift) 1.32 Total Cct Load) _ 1.20 (E=I*R) 1.57 24 - E} 22.43 DEVICES ZH-M C W @15cd z i -MC W ..L 30cd ZH-MC-W @75cd Z11 -MC -CW a(,, 95cd ZH-MC-CW @135cd ZR=MC=W @15cd 156 j 113 113: 195: _.....___..___.�.� 371'; ;Total Wire Resistance ( R Total Device Load, Amps Voltage Drop (E ) EOL .Voltage (WL*2)*(R/ft) 1.58 (Total Gct Load) 4:7'8 (E=I*R) 1.24 24 - E) 22.76 SYSTEM CALCULATIONS THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6042 DEDICATED p#RCO4CY '' NOTE FOR ADDITIONAL SPECIF1CATIONS SEE PRODUCT DOCUMENTATION. 'CONTACT RATINGS: 4.OA 0 125VAC 4.0A 0 30VDC MI DEVICE SSTIPPIF LAST FROM XLS CONTROL PANEL a DR PREVIDUS ADDRESSABLE DEVICE 0 0 0 0 HTRI-R 0 0 0 0' 0' 0' NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE CEILIN TILE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE / STROBE ONLY 0000 LI 0 PAD -3 0 00° INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - (-) (+) SPARE j SPARE j SPARE DROP CEILING MOUNTING (-) HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) u v HORN/STROBE OR STROBE ONLY U HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. -4 EE Ezo (+) TEM -1 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPUFPLR RED (JACKET) 'CONTACT RATINGS: 4.0A 0125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O 0 F GROUND ° °0 -I I Ee I HTRI-R 114 0-1 DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY METH/ELEC. (+)> TO NEXT DEVICE OR (-) >' STOP IF LAST DEVICE DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT ti 0 0 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +322'' FF (0' C) TO 100' F (38' C) HUMIDITY; 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > r>. DATA IN (+) DEVICE IS USTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR -- DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX > TO NEXT > ADDRESSABLE DEVICE HORN STROBE & STROBE WALL MOUNTING DETAIL FAX (206) 628-4990 TEL. (206) 622-6545 -z LJU ) L J J w REV. BY: DMG DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: t, If1D All IL/DTD. C A LI_ 1 o F- W o SHOP DRAWINGS DATE 09/25/13 2<<<<< } Ct '5UALL: NUI I U (;ALE. ' DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: t, If1D All IL/DTD. C A LI_ 1 • 1 SHEET FA -02 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved TO NEAREST EXISTING DATA LOOP 2C —0 r� 6-0" COL D,2S —0 a ru TO NEAREST EXISTING SIGNALING CIRCUIT 0 co V r S - a P-4111fl i JJ1J j3 d ri Sti -4 46 TYP. f S 2 CONTINUATION 2 CONTINUATION DO 2 CONTINUATION 5 j RSTROO GEILING FLM 40 41 NON -SALES AREA KEYNOTES NON -SALES OVEN TO GEL,+" /E VANITY LIGHT. SEE DETAIL 13/A-5 (E) RESTROOM EXHAJ'ST F - : TO MECHANICAL 42 DRMI NGS FOR NEW +, L L. TO VERIFY PIORKINO catorrioN 13-44 N/A 45 HAN&C16 FrtS (4) AT 12"-0" A.F.F. S 1VA-8 4b FL/ CRESCENT STRIP F * -w. ON 12-6" A.F.F, CHAN SUFpORTS AT 4T (E) GYP BD. CEILIN,.. L.L. T' 1 -FINISH PER SCHM)LE 17008 13U ii -. n - TG1 CN Mil AT 1V-0" A.F.F. REA BUZZER �_ r1'CCH AT 5'-0' A.F.F. REFER TO ELECTRICAL DRA IN65 NON -SALES ENTRY ALERT CHL'^E (1) 4 V`LRELE55 rR CE.1 S (2) FUR141SHEP BY MAJR1C . G.G. TO INSTAJL, CHIME 3 ONE 4 ONE RECOVER ON IN SALES AREA. G.G. TO YV/ "DING DON&" TONE d GET REGENa5VOLUME TO MEDIUM. 48 4q SALES AREA KEYNOTES qaii2x4 ,th TICAL T1LE GRJD SYSTEM 5Y G.G. A 20 A.F.F. REFER TO 5rLEF>r1ATON5 MISCN CEILING' GRID ORIGIN. CEILING TO HAVE EC3JAL SPACE21S ACCT,* EACH 13415{N6 I"IALL SEE DETALS SI;EET FOR TYPICAL 5PAGING OF 'CC LIC HT FIXT1. RES 22 CEILING -MOUNTED ELECTRICAL RECEPTACLE. REFER TO ELECTRICAL DR/WINGS a ALL TRACK TO BE 14GUNTED 4'-3' FROM Y1ALL UNLESS24' _ -- G'C'ri13Z E MOTU.) 23 -54.4PER SCREEN. S DETAIL 5/A-8 26 'PENDANT Ll6HT F[X1DRE, SEE ELEVATION 2/A-4 FOR MOUNTING HEI&HT, ! START WITH 1 FALL TILE AT CENTER. at N I /Ii°1Ca RCGH kiP 21 LOCATE MAL C.tJT T1LES A5 IND'iCATE?. TYP. A..L FfTTiNG ROOMS 25 REAR T OCR BUZZER ANNUNCfATCR A&/E CEILING TILE aci FITTING ROOM DOOR14EAPQR / 501111 1 -3z# ,NIA 95d 6'-O" 61..011 4-6" - ,.:.f lkr::ii !i rtttt.E i f±LUL TYP. I .. ----(— i*kl3iffrffri:fil}i2Z}. FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY FIELD MOUNTED NEXT TO EXISTING BOOSTER POWER SUPPLIES. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH. LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX IN BACKHOUSE CORRIDOR. F 1 -31/+ 3-4 1/7 () S2-2 15cd 15cd 2'40 1/41- S2-2 /4 --- ''51-7 q5cd 4-T 3/3" `T 3/4'— I tC5 ----1:3 t � Ort? r•„�,r{:� 61 1'-2 5/4" -FRF mEa7Srrffi.T.f.f. ±2'-10 1/4" i J f 37-113/4"..... _..... E ........ 52-4 t 1 bcd S2-11 -Med 30cd S2-10 15cd t. ti ri ti •R RR an Se Ra 114 .■ OR RR RR NU 1i f5 aR •5 NV fM a. NV R. Yi 11 3/4" eeffmfBa GENERAL NOTES: 1) CONTRACTOR SHALL READ AND REVEW ALL EFECIFICATTONS AND PLAN'S, ;NGLFJING MECHANICAL AL L ID ELECTRICAL. SEE TASK RFSr E)9• SBILJTY LIST FOR iNFORMAT ON ON creme FURNISHED BY MAURICE ,. 2) CONTRACTOR 94ALL FIELD VERIFY ALL miceetaNs ARP NOTIFY MAURIGES OF ANY DISCREPANCIES. 3) FELD VERIFY ASSEMBLY REC IJIREMENTS FOR CA1aHWRAP TO DETI:RMINE Ns E 5ARY CORD LEN4TH5 FOR CASH ARAP Y' RIN6. 4) CONTRACTOR TO RAISE AND / OR Rs...06Am E4SING SPRINKLER HEADS A5 REWRED FOR 1VEr U6141 LOCATIONS. Lt&HT FIXW E LOCATIONS T,E PRECEDEsICE OVER ALL OTHER CEILING BOIJIPMENT. SEE ELECTRICAL »N66. COORDNATE Y` i LAAtit:'I,.G"RU. 5) E FI Fr.TR$CAL. DETAILS FOR ALL V' IN& LAYOUTS. b) ALL. FIXTURE) TO HAVE LAMPS AS SFEGIFIE0 AN) SUPPLIED BY ?4k. ELECTRICAL CONTRACTOR SHALL FROZE ALL HARDWARE, ACC�iSa . ETC., NECESSARY FOR INCCIAL INSTALLATION. 1) CONTRACTOR TO PROVIDE ALL EUFPORT FRAMING. ALL THREAD AND IJNISTRUT ORI JAL STRUCTUT SYSTEMS TO HAN6 FIXTURES, CEILING 'MAR51104, CEILING 5'151.51, ETC,. FROM MALL STRUCTURE. LEGENO a 71'P. 71/2"\ 1X4 FLIJGRESC,ENT TROFFER 2X4 FUUOR SCENT TROfr-T 2X4 F� TROFFER NIGHT LIGHT 2X4 ELU0RESE)1 1T TROT -1 Y°tI E' M6. BALLAST 2X2 FLUORESCENT TROFFER 2X2 FI.U0nSCEJff TROFFER NRI EMtERG. BALLAST ?LQ cry-..... ._..._...___......_.i MINGLE 'TUBE FLUORESCENT STRIP pozI.E TIi13E FLUaRaCENT STRIP 7r7ij:CIT11fll11-3 Lull" SINGLE TUBE FLUORESCENT STRIP Y1/ emme. BALLAST 111 R.EC.E PO *4iJ6HT TRACK MOUNT METAL HALVE Lt6t+T FIXTURE FIRE ALARM SYSTEM PLAN r=.::i. (? f5TRO0m VANITY LIC -FIT EXTERIOR UGHT ?-? (?) — = -, LI&FIT TRACK et/ TR.A0C. HEAD TYP. 0 1' 3' S' 10' 2` 4' PALL -MUM EMER6ENCY LIGHT EXIT L1 HT - PENDANT MOUNT FIXTURE f_) EXHAUST FAN TRANSFORMER ELEC. PANEL JUNCTION SOX EWER EATON €1' O" AFF BUZZER ANNUNCIATOR CONCEALED 516N OUTLET ORIGIN POINT POOR CHIME SYSTEM 66-2i NON-S&Ea VOOR CHHE SYS—a4 Proprietary and Confidential, Copyright 2013 by Guardian Security S stems, Inc. All Rights Reserved 1,0 CO FAX (206) 628-L4.990 TEL. (206) 622-654.5 1 \ L LL/"\V L/ 1 \L V 1V1 V1 YV NO I DATE DESCRIPTION REV. BY: 1 STOREONT KEYNOTES SISN XIS- IN EILK1+EAD FGR STORE RO T SIGN. REFER BACKROUND PLAN PROVIDED BY: «• OM OF BULKH . IAT 10'..11" , F. , - 4-2- T• . T10'� •a SHOP DRAWINGS z''r A 0-"•F,:. ;I- RAN AND EIEVAl1CNS ON SHEET A-5 FOR FINISHES 4 50TTOM OF DISPLAY rovon',aGFTT AT 12-0" A.F.F. 5 f:0" E1GN GM) (rrT'. OF 6) i/A-S. _ 6 60" 516N &RiV GUT TO b" V'41DTH (TYP. OF b) Se 7/A -b T "# T 6 T F1 Nur;.. D a s ` S 1 -. ". : • C14 OF POOR IN& AT 9'-22" - .F.. R:- . TO S 3/. -51 q-tq ,. FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY FIELD MOUNTED NEXT TO EXISTING BOOSTER POWER SUPPLIES. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH. LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX IN BACKHOUSE CORRIDOR. F 1 -31/+ 3-4 1/7 () S2-2 15cd 15cd 2'40 1/41- S2-2 /4 --- ''51-7 q5cd 4-T 3/3" `T 3/4'— I tC5 ----1:3 t � Ort? r•„�,r{:� 61 1'-2 5/4" -FRF mEa7Srrffi.T.f.f. ±2'-10 1/4" i J f 37-113/4"..... _..... E ........ 52-4 t 1 bcd S2-11 -Med 30cd S2-10 15cd t. ti ri ti •R RR an Se Ra 114 .■ OR RR RR NU 1i f5 aR •5 NV fM a. NV R. Yi 11 3/4" eeffmfBa GENERAL NOTES: 1) CONTRACTOR SHALL READ AND REVEW ALL EFECIFICATTONS AND PLAN'S, ;NGLFJING MECHANICAL AL L ID ELECTRICAL. SEE TASK RFSr E)9• SBILJTY LIST FOR iNFORMAT ON ON creme FURNISHED BY MAURICE ,. 2) CONTRACTOR 94ALL FIELD VERIFY ALL miceetaNs ARP NOTIFY MAURIGES OF ANY DISCREPANCIES. 3) FELD VERIFY ASSEMBLY REC IJIREMENTS FOR CA1aHWRAP TO DETI:RMINE Ns E 5ARY CORD LEN4TH5 FOR CASH ARAP Y' RIN6. 4) CONTRACTOR TO RAISE AND / OR Rs...06Am E4SING SPRINKLER HEADS A5 REWRED FOR 1VEr U6141 LOCATIONS. Lt&HT FIXW E LOCATIONS T,E PRECEDEsICE OVER ALL OTHER CEILING BOIJIPMENT. SEE ELECTRICAL »N66. COORDNATE Y` i LAAtit:'I,.G"RU. 5) E FI Fr.TR$CAL. DETAILS FOR ALL V' IN& LAYOUTS. b) ALL. FIXTURE) TO HAVE LAMPS AS SFEGIFIE0 AN) SUPPLIED BY ?4k. ELECTRICAL CONTRACTOR SHALL FROZE ALL HARDWARE, ACC�iSa . ETC., NECESSARY FOR INCCIAL INSTALLATION. 1) CONTRACTOR TO PROVIDE ALL EUFPORT FRAMING. ALL THREAD AND IJNISTRUT ORI JAL STRUCTUT SYSTEMS TO HAN6 FIXTURES, CEILING 'MAR51104, CEILING 5'151.51, ETC,. FROM MALL STRUCTURE. LEGENO a 71'P. 71/2"\ 1X4 FLIJGRESC,ENT TROFFER 2X4 FUUOR SCENT TROfr-T 2X4 F� TROFFER NIGHT LIGHT 2X4 ELU0RESE)1 1T TROT -1 Y°tI E' M6. BALLAST 2X2 FLUORESCENT TROFFER 2X2 FI.U0nSCEJff TROFFER NRI EMtERG. BALLAST ?LQ cry-..... ._..._...___......_.i MINGLE 'TUBE FLUORESCENT STRIP pozI.E TIi13E FLUaRaCENT STRIP 7r7ij:CIT11fll11-3 Lull" SINGLE TUBE FLUORESCENT STRIP Y1/ emme. BALLAST 111 R.EC.E PO *4iJ6HT TRACK MOUNT METAL HALVE Lt6t+T FIXTURE FIRE ALARM SYSTEM PLAN r=.::i. (? f5TRO0m VANITY LIC -FIT EXTERIOR UGHT ?-? (?) — = -, LI&FIT TRACK et/ TR.A0C. HEAD TYP. 0 1' 3' S' 10' 2` 4' PALL -MUM EMER6ENCY LIGHT EXIT L1 HT - PENDANT MOUNT FIXTURE f_) EXHAUST FAN TRANSFORMER ELEC. PANEL JUNCTION SOX EWER EATON €1' O" AFF BUZZER ANNUNCIATOR CONCEALED 516N OUTLET ORIGIN POINT POOR CHIME SYSTEM 66-2i NON-S&Ea VOOR CHHE SYS—a4 Proprietary and Confidential, Copyright 2013 by Guardian Security S stems, Inc. All Rights Reserved 1,0 CO FAX (206) 628-L4.990 TEL. (206) 622-654.5 1 \ L LL/"\V L/ 1 \L V 1V1 V1 YV NO I DATE DESCRIPTION REV. BY: 0 M 0 DESIGNED BY: R. VEZZANI DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: InD KII I►ADCD. 6466-1 SHOP DRAWINGS M u) N rn 0 <<<<< LU U c 0 W U [co QT o- W ��—/�- < 0 VJ eoc z_ CC < Q LIJ� CC LL O 07 O c0 CV W LITJ 'SCALL: 1 /4--=1 -U.. DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: InD KII I►ADCD. 6466-1 SHEET FA -03 SCALE 9 71‘..A WOOS BUS SMB■ SWUM MOWN OWNS Bu■■ B__ Boum WNS■ BNS■ WOOS WOOS ORwwUcM U■ B WWW *Bus SNOW sti3 SNOW !WOW OWNS mo. ■SW■ MONS OBS■ WORM NNS. VOX. ■SS■ WOW S ONUS SIBS WOWS WOOS MOWS WOWS ■MOB ■BWU MOWN MEOW w■�s 77 :7' '7'7_-::7' WOWS MOWS OVUM ;nom ■SOS WOO Wo SM MOON BBS■ SMOON BS Sm SSSS 'i't: OSB■ ■SUB mNSw "".:'.';`OSS■ Bim■ MOO■ 'Bu■ NON■ WNW■ Bo 5BB■ SSo SSSS .w u■ Kb= woo r.W■ ;rim■■■ WOO. wrmw WOO* n ■BU■ ■U■ COL Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved 'All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart ® 52 — Add Reliable Model G5-56 Standard Response 165° Concealed Pendents 1/2 x 1/2 (white) o 5 — Add Reliable Model G Standard Response 165° Brass Uprights 1/2 x 1/2 COL RETAINER STRAP WHERE REWIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL 'THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS a 0 TED Will lout Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conf orrnarIce with current City ,standards. Acceptance is subject to errors and : )rnissions which do not authorize violations of adopted ,tandards and ordinances. The responsibility for the �equacy of design rests totally with the designer. till ions, deletions or revisions to these drawings after -:-ds date will void this acceptance and will require a • --:submittal of revised drawings for suosequent approval. acceptance is subiect to field test and inspection by ne Tukwila Fre Prevention Bureau. Date:10 13 By: Ayr, S J I TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. 3 -S- and exact address for shut- down hutdown or restoration approval. L --ILA CROWN. FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7689 M au ri ces \b5 \ Southcenter Mall Tukwila, WA DATE: q 1(013 DRAWN: ( 3' U MALJRICES FIRE ALARM SYSTEM ADITION TUKWILA, WASHINGTON 0 .hese plans ha,,c :,',ention C�;r1:• ndards. ACc- sit .Tlards ;rev n: Iter Tukwila Fire current City "�• and adopted tht esuotriitti approval. 'final acceptai c- .1.210 test aid Inspection by NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing SHEET \U v 3ESHEET TITLE FA -01 SYSTE v I\F0� v ATO \ 8c S \GLE LINE DIAGA v FA -02 TYPICAL WI A\D VVO,\TI\G 3IAGAv S 8c CALCULATIO\S FA -03 FRE ALAS V PLA\ SHEET INDEX QUANTITY 1 1 2 6 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP ® SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM -_ - .-_TEST_ DUCT DETECTOR TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM DI HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM 13 HORN STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM JUNCTION ❑� BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS L EGEND WISE SCHEDULE A\D CO\DUIT FILL CHAT WIRE DESIGNATION DMG SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR` .RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS ' AREA TWO 600V #12 AWG THHN/THWN .244 0.D. , .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. C .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, \.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARv1 PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUVBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROv1 THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED NORDSTROM 3 LEVELS 171,275sf GEv�NESCO �,HL�� 0 MOM KYON IDODIVI� I AVON 1 rr Moue CORA. 8 PN0 &000 „f5,9OE tO1 macys 4 LEVELS 250,407st MAINS 00 11 oate:JO - 3 . 0,000 O1001NON TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. and exact I' {t - down or r'cs crit cri e; pprov3I. ut,CHO 0000100 1HE 1510 SKOP"- 5.1100 TO DO 11NDER 005 ,- MOWN 0055 NANI RECK IA THE. NAND. NCA I 100001AJt EI1 '1 L i1 50 6 10 8 OE_s1 Guy O01LE 9.,00 N COLD 41WEIS L 1 CA1CI7lTAWS10110 SS JOUR':EYS 0 91E1K SHOES SHEIK SHOES THE 000. 0 LIDS. 5500 PINION J0W0EE KING COUNTY 0ORARY 11.GWELERS50 00,1.0 0 11 EOISTIN JCPenney 3 LEYEL`: 276,468sf 010000 SIJHF MAURICES #2800 / SPACE #408 KEY PLAN TO NEAREST EXISTING SIGNALING CIRCUIT 2c 120VAC, DEDICATED (BY OTHERS) 1 4> - FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY FIELD MOUNTED NEXT TO EXISTING BOOSTER POWER SUPPLIES. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH. LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX IN BACKHOUSE CORRIDOR. S2-1 S2-2 S2-3 S2-4 S2-5 15cd 15cd 30cd 15cd 15cd S2-6 S2-7 S2-8 S2-9 S2-10 S2-11 15cd 15cd 15cd 15cd 15cd 15cd 2S J TO NEAREST EXISTING 2 DATA LOOP S1-1 S1-2 S1-3' S1-4 S1-5 95cd 15cd 15cd15cd 15cd D I HT -R D,I -� I HT -R1 2I` -c TSM S1-6 S1-7 S1-8 15cd 95cd 95cd EOL S1 EOL S2 PAID ", ?fl11 -z co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 1 \L. LL1-r,V L/ 1 \L V 1 1 N./ 1 VV NO I DATE I DESCRIPTION REV. BY: DMG DESIGNED BY: R. VEZZANI DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: 1 nm NIIIAARI'm. PAPP-1 SHOP DRAWINGS M N rn 0 <<<<< } 0 w U 00 Q� �rn w V2 QO 0 cf) EE = D g cc". Q Q2 1E2 �� u_ 0s- 0 0 CC Z 'UALL: NUT IO SCALL DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: 1 nm NIIIAARI'm. PAPP-1 • WIRE DESIGNATION GENERAL NOTES SINGLE LINE DIAGRAM 2227% Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -012 Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0:0022 0.0022 0.0023 0.002 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps R nal a'cu ;u Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CWc� 15CD 0.087 ZH-MC-CW @30CD 1 0.131 ZH-MC-tt11. Cc 75CD. 0.222 ZH-MC-CW @95CD 3 0.292 0.876 al -HMC -CW @135CD 0.371 ZR -MC -CW @15CD 0.069 ZR -MC- 15CD 13 0.064 0.832. 0.03 Amps 1.738 Amps Standby. Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm: Current Load: 1.738 Amps For 5 Minute 0.146 Amp -hours 25% Derating= 1.082 Amp -hours Total System Current Load: 1.082 Amp -hours Notification Appliance Circuit Detail PROJECT: MAURICES Panel: PAD -3 BPS Date: September 26, 2013 Wire Resistance 2.58 CURRENT TOTAL= 1977.00 -CW @15cd .M. `.... ZH-MC-GW_ ZH-MC-CW @75cd ZH-MC�CW @95cd.. ZH- MC -CW @135cd 2R -MC -W 15cd DEVICES 8 87 131. 222;~ - 292- 371 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E) Voltage 0 0 O j_.. 876 0 320- 1196] 14 255 22.43 1196 WL*2)*(Rift) 1.32 Total Cct Load) _ 1.20 (E=I*R) 1.57 24 - E} 22.43 DEVICES ZH-M C W @15cd z i -MC W ..L 30cd ZH-MC-W @75cd Z11 -MC -CW a(,, 95cd ZH-MC-CW @135cd ZR=MC=W @15cd 156 j 113 113: 195: _.....___..___.�.� 371'; ;Total Wire Resistance ( R Total Device Load, Amps Voltage Drop (E ) EOL .Voltage (WL*2)*(R/ft) 1.58 (Total Gct Load) 4:7'8 (E=I*R) 1.24 24 - E) 22.76 SYSTEM CALCULATIONS THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6042 DEDICATED p#RCO4CY '' NOTE FOR ADDITIONAL SPECIF1CATIONS SEE PRODUCT DOCUMENTATION. 'CONTACT RATINGS: 4.OA 0 125VAC 4.0A 0 30VDC MI DEVICE SSTIPPIF LAST FROM XLS CONTROL PANEL a DR PREVIDUS ADDRESSABLE DEVICE 0 0 0 0 HTRI-R 0 0 0 0' 0' 0' NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE CEILIN TILE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE / STROBE ONLY 0000 LI 0 PAD -3 0 00° INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - (-) (+) SPARE j SPARE j SPARE DROP CEILING MOUNTING (-) HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) u v HORN/STROBE OR STROBE ONLY U HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. -4 EE Ezo (+) TEM -1 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPUFPLR RED (JACKET) 'CONTACT RATINGS: 4.0A 0125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O 0 F GROUND ° °0 -I I Ee I HTRI-R 114 0-1 DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY METH/ELEC. (+)> TO NEXT DEVICE OR (-) >' STOP IF LAST DEVICE DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT ti 0 0 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +322'' FF (0' C) TO 100' F (38' C) HUMIDITY; 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > r>. DATA IN (+) DEVICE IS USTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR -- DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX > TO NEXT > ADDRESSABLE DEVICE HORN STROBE & STROBE WALL MOUNTING DETAIL FAX (206) 628-4990 TEL. (206) 622-6545 -z LJU ) L J J w REV. BY: DMG DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: t, If1D All IL/DTD. C A LI_ 1 o F- W o SHOP DRAWINGS DATE 09/25/13 2<<<<< } Ct '5UALL: NUI I U (;ALE. ' DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: t, If1D All IL/DTD. C A LI_ 1 • 1 SHEET FA -02 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved TO NEAREST EXISTING DATA LOOP 2C —0 r� 6-0" COL D,2S —0 a ru TO NEAREST EXISTING SIGNALING CIRCUIT 0 co V r S - a P-4111fl i JJ1J j3 d ri Sti -4 46 TYP. f S 2 CONTINUATION 2 CONTINUATION DO 2 CONTINUATION 5 j RSTROO GEILING FLM 40 41 NON -SALES AREA KEYNOTES NON -SALES OVEN TO GEL,+" /E VANITY LIGHT. SEE DETAIL 13/A-5 (E) RESTROOM EXHAJ'ST F - : TO MECHANICAL 42 DRMI NGS FOR NEW +, L L. TO VERIFY PIORKINO catorrioN 13-44 N/A 45 HAN&C16 FrtS (4) AT 12"-0" A.F.F. S 1VA-8 4b FL/ CRESCENT STRIP F * -w. ON 12-6" A.F.F, CHAN SUFpORTS AT 4T (E) GYP BD. CEILIN,.. L.L. T' 1 -FINISH PER SCHM)LE 17008 13U ii -. n - TG1 CN Mil AT 1V-0" A.F.F. REA BUZZER �_ r1'CCH AT 5'-0' A.F.F. REFER TO ELECTRICAL DRA IN65 NON -SALES ENTRY ALERT CHL'^E (1) 4 V`LRELE55 rR CE.1 S (2) FUR141SHEP BY MAJR1C . G.G. TO INSTAJL, CHIME 3 ONE 4 ONE RECOVER ON IN SALES AREA. G.G. TO YV/ "DING DON&" TONE d GET REGENa5VOLUME TO MEDIUM. 48 4q SALES AREA KEYNOTES qaii2x4 ,th TICAL T1LE GRJD SYSTEM 5Y G.G. A 20 A.F.F. REFER TO 5rLEF>r1ATON5 MISCN CEILING' GRID ORIGIN. CEILING TO HAVE EC3JAL SPACE21S ACCT,* EACH 13415{N6 I"IALL SEE DETALS SI;EET FOR TYPICAL 5PAGING OF 'CC LIC HT FIXT1. RES 22 CEILING -MOUNTED ELECTRICAL RECEPTACLE. REFER TO ELECTRICAL DR/WINGS a ALL TRACK TO BE 14GUNTED 4'-3' FROM Y1ALL UNLESS24' _ -- G'C'ri13Z E MOTU.) 23 -54.4PER SCREEN. S DETAIL 5/A-8 26 'PENDANT Ll6HT F[X1DRE, SEE ELEVATION 2/A-4 FOR MOUNTING HEI&HT, ! START WITH 1 FALL TILE AT CENTER. at N I /Ii°1Ca RCGH kiP 21 LOCATE MAL C.tJT T1LES A5 IND'iCATE?. TYP. A..L FfTTiNG ROOMS 25 REAR T OCR BUZZER ANNUNCfATCR A&/E CEILING TILE aci FITTING ROOM DOOR14EAPQR / 501111 1 -3z# ,NIA 95d 6'-O" 61..011 4-6" - ,.:.f lkr::ii !i rtttt.E i f±LUL TYP. I .. ----(— i*kl3iffrffri:fil}i2Z}. FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY FIELD MOUNTED NEXT TO EXISTING BOOSTER POWER SUPPLIES. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH. LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX IN BACKHOUSE CORRIDOR. F 1 -31/+ 3-4 1/7 () S2-2 15cd 15cd 2'40 1/41- S2-2 /4 --- ''51-7 q5cd 4-T 3/3" `T 3/4'— I tC5 ----1:3 t � Ort? r•„�,r{:� 61 1'-2 5/4" -FRF mEa7Srrffi.T.f.f. ±2'-10 1/4" i J f 37-113/4"..... _..... E ........ 52-4 t 1 bcd S2-11 -Med 30cd S2-10 15cd t. ti ri ti •R RR an Se Ra 114 .■ OR RR RR NU 1i f5 aR •5 NV fM a. NV R. Yi 11 3/4" eeffmfBa GENERAL NOTES: 1) CONTRACTOR SHALL READ AND REVEW ALL EFECIFICATTONS AND PLAN'S, ;NGLFJING MECHANICAL AL L ID ELECTRICAL. SEE TASK RFSr E)9• SBILJTY LIST FOR iNFORMAT ON ON creme FURNISHED BY MAURICE ,. 2) CONTRACTOR 94ALL FIELD VERIFY ALL miceetaNs ARP NOTIFY MAURIGES OF ANY DISCREPANCIES. 3) FELD VERIFY ASSEMBLY REC IJIREMENTS FOR CA1aHWRAP TO DETI:RMINE Ns E 5ARY CORD LEN4TH5 FOR CASH ARAP Y' RIN6. 4) CONTRACTOR TO RAISE AND / OR Rs...06Am E4SING SPRINKLER HEADS A5 REWRED FOR 1VEr U6141 LOCATIONS. Lt&HT FIXW E LOCATIONS T,E PRECEDEsICE OVER ALL OTHER CEILING BOIJIPMENT. SEE ELECTRICAL »N66. COORDNATE Y` i LAAtit:'I,.G"RU. 5) E FI Fr.TR$CAL. DETAILS FOR ALL V' IN& LAYOUTS. b) ALL. FIXTURE) TO HAVE LAMPS AS SFEGIFIE0 AN) SUPPLIED BY ?4k. ELECTRICAL CONTRACTOR SHALL FROZE ALL HARDWARE, ACC�iSa . ETC., NECESSARY FOR INCCIAL INSTALLATION. 1) CONTRACTOR TO PROVIDE ALL EUFPORT FRAMING. ALL THREAD AND IJNISTRUT ORI JAL STRUCTUT SYSTEMS TO HAN6 FIXTURES, CEILING 'MAR51104, CEILING 5'151.51, ETC,. FROM MALL STRUCTURE. LEGENO a 71'P. 71/2"\ 1X4 FLIJGRESC,ENT TROFFER 2X4 FUUOR SCENT TROfr-T 2X4 F� TROFFER NIGHT LIGHT 2X4 ELU0RESE)1 1T TROT -1 Y°tI E' M6. BALLAST 2X2 FLUORESCENT TROFFER 2X2 FI.U0nSCEJff TROFFER NRI EMtERG. BALLAST ?LQ cry-..... ._..._...___......_.i MINGLE 'TUBE FLUORESCENT STRIP pozI.E TIi13E FLUaRaCENT STRIP 7r7ij:CIT11fll11-3 Lull" SINGLE TUBE FLUORESCENT STRIP Y1/ emme. BALLAST 111 R.EC.E PO *4iJ6HT TRACK MOUNT METAL HALVE Lt6t+T FIXTURE FIRE ALARM SYSTEM PLAN r=.::i. (? f5TRO0m VANITY LIC -FIT EXTERIOR UGHT ?-? (?) — = -, LI&FIT TRACK et/ TR.A0C. HEAD TYP. 0 1' 3' S' 10' 2` 4' PALL -MUM EMER6ENCY LIGHT EXIT L1 HT - PENDANT MOUNT FIXTURE f_) EXHAUST FAN TRANSFORMER ELEC. PANEL JUNCTION SOX EWER EATON €1' O" AFF BUZZER ANNUNCIATOR CONCEALED 516N OUTLET ORIGIN POINT POOR CHIME SYSTEM 66-2i NON-S&Ea VOOR CHHE SYS—a4 Proprietary and Confidential, Copyright 2013 by Guardian Security S stems, Inc. All Rights Reserved 1,0 CO FAX (206) 628-L4.990 TEL. (206) 622-654.5 1 \ L LL/"\V L/ 1 \L V 1V1 V1 YV NO I DATE DESCRIPTION REV. BY: 1 STOREONT KEYNOTES SISN XIS- IN EILK1+EAD FGR STORE RO T SIGN. REFER BACKROUND PLAN PROVIDED BY: «• OM OF BULKH . IAT 10'..11" , F. , - 4-2- T• . T10'� •a SHOP DRAWINGS z''r A 0-"•F,:. ;I- RAN AND EIEVAl1CNS ON SHEET A-5 FOR FINISHES 4 50TTOM OF DISPLAY rovon',aGFTT AT 12-0" A.F.F. 5 f:0" E1GN GM) (rrT'. OF 6) i/A-S. _ 6 60" 516N &RiV GUT TO b" V'41DTH (TYP. OF b) Se 7/A -b T "# T 6 T F1 Nur;.. D a s ` S 1 -. ". : • C14 OF POOR IN& AT 9'-22" - .F.. R:- . TO S 3/. -51 q-tq ,. FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY FIELD MOUNTED NEXT TO EXISTING BOOSTER POWER SUPPLIES. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH. LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX IN BACKHOUSE CORRIDOR. F 1 -31/+ 3-4 1/7 () S2-2 15cd 15cd 2'40 1/41- S2-2 /4 --- ''51-7 q5cd 4-T 3/3" `T 3/4'— I tC5 ----1:3 t � Ort? r•„�,r{:� 61 1'-2 5/4" -FRF mEa7Srrffi.T.f.f. ±2'-10 1/4" i J f 37-113/4"..... _..... E ........ 52-4 t 1 bcd S2-11 -Med 30cd S2-10 15cd t. ti ri ti •R RR an Se Ra 114 .■ OR RR RR NU 1i f5 aR •5 NV fM a. NV R. Yi 11 3/4" eeffmfBa GENERAL NOTES: 1) CONTRACTOR SHALL READ AND REVEW ALL EFECIFICATTONS AND PLAN'S, ;NGLFJING MECHANICAL AL L ID ELECTRICAL. SEE TASK RFSr E)9• SBILJTY LIST FOR iNFORMAT ON ON creme FURNISHED BY MAURICE ,. 2) CONTRACTOR 94ALL FIELD VERIFY ALL miceetaNs ARP NOTIFY MAURIGES OF ANY DISCREPANCIES. 3) FELD VERIFY ASSEMBLY REC IJIREMENTS FOR CA1aHWRAP TO DETI:RMINE Ns E 5ARY CORD LEN4TH5 FOR CASH ARAP Y' RIN6. 4) CONTRACTOR TO RAISE AND / OR Rs...06Am E4SING SPRINKLER HEADS A5 REWRED FOR 1VEr U6141 LOCATIONS. Lt&HT FIXW E LOCATIONS T,E PRECEDEsICE OVER ALL OTHER CEILING BOIJIPMENT. SEE ELECTRICAL »N66. COORDNATE Y` i LAAtit:'I,.G"RU. 5) E FI Fr.TR$CAL. DETAILS FOR ALL V' IN& LAYOUTS. b) ALL. FIXTURE) TO HAVE LAMPS AS SFEGIFIE0 AN) SUPPLIED BY ?4k. ELECTRICAL CONTRACTOR SHALL FROZE ALL HARDWARE, ACC�iSa . ETC., NECESSARY FOR INCCIAL INSTALLATION. 1) CONTRACTOR TO PROVIDE ALL EUFPORT FRAMING. ALL THREAD AND IJNISTRUT ORI JAL STRUCTUT SYSTEMS TO HAN6 FIXTURES, CEILING 'MAR51104, CEILING 5'151.51, ETC,. FROM MALL STRUCTURE. LEGENO a 71'P. 71/2"\ 1X4 FLIJGRESC,ENT TROFFER 2X4 FUUOR SCENT TROfr-T 2X4 F� TROFFER NIGHT LIGHT 2X4 ELU0RESE)1 1T TROT -1 Y°tI E' M6. BALLAST 2X2 FLUORESCENT TROFFER 2X2 FI.U0nSCEJff TROFFER NRI EMtERG. BALLAST ?LQ cry-..... ._..._...___......_.i MINGLE 'TUBE FLUORESCENT STRIP pozI.E TIi13E FLUaRaCENT STRIP 7r7ij:CIT11fll11-3 Lull" SINGLE TUBE FLUORESCENT STRIP Y1/ emme. BALLAST 111 R.EC.E PO *4iJ6HT TRACK MOUNT METAL HALVE Lt6t+T FIXTURE FIRE ALARM SYSTEM PLAN r=.::i. (? f5TRO0m VANITY LIC -FIT EXTERIOR UGHT ?-? (?) — = -, LI&FIT TRACK et/ TR.A0C. HEAD TYP. 0 1' 3' S' 10' 2` 4' PALL -MUM EMER6ENCY LIGHT EXIT L1 HT - PENDANT MOUNT FIXTURE f_) EXHAUST FAN TRANSFORMER ELEC. PANEL JUNCTION SOX EWER EATON €1' O" AFF BUZZER ANNUNCIATOR CONCEALED 516N OUTLET ORIGIN POINT POOR CHIME SYSTEM 66-2i NON-S&Ea VOOR CHHE SYS—a4 Proprietary and Confidential, Copyright 2013 by Guardian Security S stems, Inc. All Rights Reserved 1,0 CO FAX (206) 628-L4.990 TEL. (206) 622-654.5 1 \ L LL/"\V L/ 1 \L V 1V1 V1 YV NO I DATE DESCRIPTION REV. BY: 0 M 0 DESIGNED BY: R. VEZZANI DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: InD KII I►ADCD. 6466-1 SHOP DRAWINGS M u) N rn 0 <<<<< LU U c 0 W U [co QT o- W ��—/�- < 0 VJ eoc z_ CC < Q LIJ� CC LL O 07 O c0 CV W LITJ 'SCALL: 1 /4--=1 -U.. DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/25/13 BACKROUND PLAN PROVIDED BY: InD KII I►ADCD. 6466-1 SHEET FA -03 SCALE 9 71‘..A WOOS BUS SMB■ SWUM MOWN OWNS Bu■■ B__ Boum WNS■ BNS■ WOOS WOOS ORwwUcM U■ B WWW *Bus SNOW sti3 SNOW !WOW OWNS mo. ■SW■ MONS OBS■ WORM NNS. VOX. ■SS■ WOW S ONUS SIBS WOWS WOOS MOWS WOWS ■MOB ■BWU MOWN MEOW w■�s 77 :7' '7'7_-::7' WOWS MOWS OVUM ;nom ■SOS WOO Wo SM MOON BBS■ SMOON BS Sm SSSS 'i't: OSB■ ■SUB mNSw "".:'.';`OSS■ Bim■ MOO■ 'Bu■ NON■ WNW■ Bo 5BB■ SSo SSSS .w u■ Kb= woo r.W■ ;rim■■■ WOO. wrmw WOO* n ■BU■ ■U■ COL Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved 'All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart ® 52 — Add Reliable Model G5-56 Standard Response 165° Concealed Pendents 1/2 x 1/2 (white) o 5 — Add Reliable Model G Standard Response 165° Brass Uprights 1/2 x 1/2 COL RETAINER STRAP WHERE REWIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL 'THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS a 0 TED Will lout Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conf orrnarIce with current City ,standards. Acceptance is subject to errors and : )rnissions which do not authorize violations of adopted ,tandards and ordinances. The responsibility for the �equacy of design rests totally with the designer. till ions, deletions or revisions to these drawings after -:-ds date will void this acceptance and will require a • --:submittal of revised drawings for suosequent approval. acceptance is subiect to field test and inspection by ne Tukwila Fre Prevention Bureau. Date:10 13 By: Ayr, S J I TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. 3 -S- and exact address for shut- down hutdown or restoration approval. L --ILA CROWN. FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7689 M au ri ces \b5 \ Southcenter Mall Tukwila, WA DATE: q 1(013 DRAWN: ( 3' U