HomeMy WebLinkAboutPP - 1071 SOUTHCENTER MALL - VANS INC - PERMITS AND PLANS1071 SOUTHCENTER MALL
ASSOCIATED PERMITS
13-F-241
13-S-235
13-S-231
4401%
SITE LOCATION
Site Address:
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
PI D
S°
cp26� 3
TUKWILA FIRE
King Co. Assessor's Tax No.:
107/ 5 thC• k Medi
Tenant Name: /7UVV P'k eS
Property Owner's Name:
Suite Number: Floor:
New Tenant? ❑ - Yes 111- No
Mailing Address:
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name )toIrtx_ r ! l SL 1 Day Telephone: 4/ • yr1.76169
Crows Fe 3 chi
Mailing Address: 'FV x 12\ \ rn 1 11 CP!'er , GOCZ
E-mail Address: - & _.jA 1. 0m Fax Number: I/2 • 1#f • q
Company Name:
Total number of new/relocated devices or sprinkler heads: 5 7
Valuation of Project (contractor's bid price): $ 5 76-0
Scope of Work (please provide detailed information):
PS64A. C57) Sir/ p I a fr
PERMIT APPLICATION NOTES
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: ei11167'� ? �+
Print Name: (,J 2 RO YA
Date: r2 �3
Day Telephone: 4/24-- 4/07C06.7
Plan Permit App.doc 1/2/13 TFD FP Form 8
SITE LOCATION
.4as
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.: 9202470010
Site Address. Outhcenter Mali, Tukwila, 98188 Suite Number: space 408 Floor:
Tenant Name: Maurices New Tenant? H- Yes ❑ - No
Property owner's Name: Westfield Property Tax Dept.
Mailing Address: POB 130940, Carlsbad, CA 92013
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: Karina Veliz Day Telephone: 206.349.5889
Company Name: Guardian Security Systems
Mailing Address:1743 First Ave South, Seattle, WA 98134
kveliz@guardiansecurity.com City
E-mail Address: Fax Number: 206 628.4990
State Zip
Total number of new/relocated devices or sprinkler heads:
l 1 jjj
Valuation of Project (contractor's bid price).
b® -
Scope of Work (please provide detailed information): Adding 25 devices to existing FACP
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING 1 OR A;UTHORIZ D AGENT:
Signature: I Date: - (2:1-
Print Name: Karina Veliz Day Telephone: 206.349.5889
Plan Permit App.doc
1/2/13 TFD FP Form 8
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Maurices
1071 Southcenter Mall
Permit No.: 13-S-235
Date: October 2, 2013
Reviewer:
Al Metzler
Fire Protection Project Coordinator
(206) 575-4407 option # 2 (Inspection Requests)
(206) 971-8718 (Plan Review Questions)
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the last length of
pipe but within 6' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40 ' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2 for pipe size 2 1/2 inches and larger.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-05, section 13.5.6.2.2.
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
• All valves controlling the water supply for automatic sprinkler systems and
waterflow switches on all sprinkler systems shall be electrically supervised.
• Comply with obstructed/non-obstructed construction rules for sprinkler head
placement.
• Sprinkler heads spaced closer than 6 ft. apart must be baffled.
• Modifications involving 20 or more heads require hydrostatic test and system
isolation if necessary.
• For dry pipe and double interlock preaction systems, in addition to the standard
hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24
hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the
24 hours shall be corrected.
• These conditions apply to all sprinkler piping exposed as necessary to
accomplish the permitted scope of work.
All code references are NFPA 13, 2013 Edition.
09/27/2013 11:48 4254818695
FAX TRANSMITTAL
CROWN FIRE PACE 01/01
Fax No.
CROWN FIRE PROTECTION, INC.
9.27.13
Fire Prevention Bureau
Tukwila Fire Department / Al
Demo Permit
Number of Pages (including- Co. er)
1
0 Urgent E✓ For Review ❑ Please Comment 0 Please Reply
206.575.4439
From
Czistie Ogland
PH:425.481.7669
FX:425.481.8695
Comments
Please provide a demo permit to remove (6) sprinkler heads out of the framing at the Maurcies project
at 1011 Southcenter Mall. The building permit # is D13-260. Please let us know if you have any
questions.
Thanks—
TUKWILA FIRE DEPARTMEIV7.
Please call 206-575-4407 and
give this Fire Permit No.
s " 031
Ind exact address for shut
town or restoration
approval.
P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8695
MALJRICES
FIRE ALARM SYSTEM ADITION
TUKWILA, WASHINGTON
0
.hese plans ha,,c
:,',ention C�;r1:•
ndards. ACc-
sit
.Tlards
;rev n:
Iter
Tukwila Fire
current City
"�• and
adopted
tht
esuotriitti approval.
'final acceptai c- .1.210 test aid Inspection by
NOTICE
A completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testing
SHEET \U v 3ESHEET TITLE
FA -01
SYSTE
v
I\F0�
v
ATO \
8c S \GLE LINE DIAGA
v
FA -02
TYPICAL WI
A\D VVO,\TI\G 3IAGAv
S 8c CALCULATIO\S
FA -03
FRE ALAS V
PLA\
SHEET INDEX
QUANTITY
1
1
2
6
SYMBOL DESCRIPTION
MODEL
MANUFACTURER BACKBOX
MOUNTING HEIGHT
BPS
REMOTE BOOSTER
POWER SUPPLY
PAD -3
SIEMENS
PAD-3-ENCL 66" A.F.F.
TO TOP
® SMOKE DETECTOR HFP-1 1 W/ SIEMENS
(PHOTO -ADDRESSABLE) DB -11 BASE
4S DEEP
W/ 1G RING
CEILING
® DUCT DETECTOR
D
AD2-P W/ SIEMENS
HFP-11 DET.
DUCT HOUSING VERIFY
IN FIELD
TSM
-_ - .-_TEST_
DUCT DETECTOR
TSM -1
SIEMENS
1 -GANG BOX
VERIFY
IN FIELD
HT -R
INTERFACE MODULE HTRI-R
WITH RELAY
SIEMENS
4S DEEP BOX
VERIFY
IN FIELD
FIRE ALARM
DI HORN STROBE
(CEILING MOUNT)
ZH-MC-CW SIEMENS
4S DEEP BOX CEILING
FIRE ALARM
13 HORN STROBE
(WALL MOUNT)
ZR -MC -W SIEMENS
4S DEEP BOX
80" A.F.F.
TO BOTTOM
JUNCTION
❑� BOX
F.B.O.
F.B.O.
N/A
VERIFY
IN FIELD
A.F.F.
ABOVE FINISHED
FLOOR
N/A
N/A
N/A
N/A
EX
EXISTING
DEVICE
N/A
N/A
N/A
N/A
F.B.O.
FURNISHED BY
OTHERS
N/A
N/A
N/A
N/A
N/A
NOT
APPLICABLE
N/A
N/A
N/A
N/A
RED
AS BUILT
ADD OR CHANGE
N/A
N/A
N/A
N/A
GREEN
AS BUILT
REMOVE
N/A
N/A
N/A
N/A
BLUE
AS BUILT
NOTES TO CAD
N/A
N/A
N/A
N/A
SYMBOLS L EGEND
WISE SCHEDULE A\D CO\DUIT FILL CHAT
WIRE DESIGNATION
DMG
SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE
C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR` .RED (JACKET)
D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET)
P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET)
S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET)
S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET)
V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET)
V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET)
I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET)
CONDUIT FILL CHART
NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS ' AREA
TWO 600V #12 AWG THHN/THWN .244 0.D. , .0467
TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. C .0346
TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191
CONDUIT FILL
CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE
ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM
THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE.
CONDUIT SIZE MAXIMUM FILL
1/2" .12 SQUARE INCH
3/4" .21 SQUARE INCH
1" .34 SQUARE INCH
1-1/8" .60 SQUARE INCH
1-1/2" .82 SQUARE INCH
2" 1.34 SQUARE INCH
FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4.
SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END
FOR SIEMENS SYSTEM:
DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED
WITH DEVICES ADDRESS.
1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS
DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1.
2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED.
3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL
BRANCHING IS PERMISSIBLE
4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL
ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION.
5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS,
STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT)
ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION.
6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT
AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1
7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY,
TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY,
AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION.
INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED
DRAWINGS FOR "AS BUILT" PURPOSES.
9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT
SHEETS AND/OR INSTALLATION INSTRUCTIONS.
10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS
MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, \.E.C. AND NFPA 72,
SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER
SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARv1 PANEL WITHOUT
DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN.
11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT
OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS.
12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE
ACTIVATION DEVICE.
13. ALL PANEL NUVBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET.
14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROv1 THE EMERGENCY
GENERATOR.
15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER
THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL.
EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION
FOR PROTECTION DURING CONSTRUCTION.
DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL
TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72
CHAPTER 7.
16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT
AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR
OTHER BACK BOXES OF DIFFERENT CIRCUITS.
17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND
AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO
FINAL EQUIPMENT TRIM.
18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A
PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP.
19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE
OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES
AFTER COMPLETION OF THEIR INSTALLATION.
20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH
IT IS LOCATED.
21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT.
22.
23.
NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING
PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE
INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING
FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE
ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT
CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE.,
MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY.
NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE
ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES.
THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE
CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM
SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE
THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE
CABLE IS INSTALLED
NORDSTROM
3 LEVELS
171,275sf
GEv�NESCO �,HL��
0
MOM KYON
IDODIVI� I
AVON 1
rr
Moue CORA.
8
PN0 &000 „f5,9OE tO1
macys
4 LEVELS
250,407st
MAINS
00 11
oate:JO - 3 .
0,000 O1001NON
TUKWILA FIRE DEPARTMENT
Please call 206-5754407 and
give this Fire Permit No.
and exact I' {t -
down or r'cs crit cri e; pprov3I.
ut,CHO
0000100
1HE 1510 SKOP"-
5.1100 TO DO
11NDER 005 ,-
MOWN 0055 NANI
RECK IA
THE. NAND. NCA I 100001AJt
EI1 '1 L i1
50
6
10
8
OE_s1 Guy
O01LE
9.,00 N COLD
41WEIS L 1
CA1CI7lTAWS10110
SS
JOUR':EYS 0
91E1K SHOES
SHEIK SHOES
THE 000.
0 LIDS.
5500
PINION
J0W0EE
KING COUNTY 0ORARY
11.GWELERS50 00,1.0 0
11
EOISTIN
JCPenney
3 LEYEL`:
276,468sf
010000 SIJHF
MAURICES
#2800 / SPACE #408
KEY PLAN
TO NEAREST EXISTING
SIGNALING CIRCUIT
2c
120VAC, DEDICATED
(BY OTHERS)
1
4> -
FLAG NOTES:
FIELD LOCATE RELAY MODULE FOR
BACKGROUND MUSIC INTERFACE.
NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY
FIELD MOUNTED NEXT TO EXISTING BOOSTER
POWER SUPPLIES. AC POWER BY EC FROM
DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH
CIRCUIT.
DUCT DETECTOR, RELAY MODULE FOR FAN
SHUTDOWN & TEST SWITCH. LOCATIONS TO BE
FIELD VERIFIED BY MECHANICAL, ELECTRICAL
AND FIRE ALARM CONTRACTORS.
FIELD LOCATE TENANT JUNCTION BOX IN
BACKHOUSE CORRIDOR.
S2-1 S2-2 S2-3 S2-4 S2-5
15cd 15cd 30cd 15cd 15cd
S2-6 S2-7 S2-8 S2-9 S2-10 S2-11
15cd 15cd 15cd 15cd 15cd 15cd
2S
J
TO NEAREST EXISTING 2
DATA LOOP
S1-1 S1-2 S1-3' S1-4 S1-5
95cd 15cd 15cd15cd 15cd
D
I HT -R
D,I -�
I HT -R1
2I` -c
TSM
S1-6 S1-7 S1-8
15cd 95cd 95cd
EOL
S1
EOL
S2
PAID
", ?fl11
-z
co
0'
1743 IST AVE. SO., SEATTLE, WASHINGTON
FAX (206) 628-4990
TEL. (206) 622-6545
1 \L. LL1-r,V L/ 1 \L V 1 1 N./ 1 VV
NO I DATE I DESCRIPTION REV. BY:
DMG
DESIGNED BY:
R. VEZZANI
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
1 nm NIIIAARI'm. PAPP-1
SHOP DRAWINGS
M
N
rn
0
<<<<<
}
0
w
U 00
Q�
�rn
w V2 QO
0 cf)
EE =
D g cc".
Q Q2 1E2
��
u_ 0s-
0
0
CC
Z
'UALL: NUT IO SCALL
DRAWN BY:
D. GARCIA
DESIGNED BY:
R. VEZZANI
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
1 nm NIIIAARI'm. PAPP-1
•
WIRE DESIGNATION
GENERAL NOTES
SINGLE LINE DIAGRAM
2227%
Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
SHEET
FA -012
Current Load:
Standby:
Alarm:
Device Type
Qty
Amps
Total
Amps
Total
HFP-11
0:0022
0.0022
0.0023
0.002
AD2-P
1
0.0635
0.0635
0.064
0.064
HTR -R
2
0.009600
0.0096
0.021
0.042
0.0731
Amps
0.106
Amps
R
nal
a'cu
;u
Device Type
Qty
Amps
Total
Amps
Total
Main System Board
1
0.03
0.03
0.030
0.030
ZH-MC-CWc� 15CD
0.087
ZH-MC-CW @30CD
1
0.131
ZH-MC-tt11. Cc 75CD.
0.222
ZH-MC-CW @95CD
3
0.292
0.876
al -HMC -CW @135CD
0.371
ZR -MC -CW @15CD
0.069
ZR -MC- 15CD
13
0.064
0.832.
0.03
Amps
1.738
Amps
Standby. Current Load:
0.03
Amps
For 24 Hours =
0.720
Amp -hours
Alarm: Current Load:
1.738
Amps
For 5 Minute
0.146
Amp -hours
25% Derating=
1.082
Amp -hours
Total System Current Load:
1.082
Amp -hours
Notification Appliance Circuit Detail
PROJECT: MAURICES
Panel: PAD -3 BPS
Date: September 26, 2013
Wire Resistance 2.58
CURRENT TOTAL= 1977.00
-CW @15cd .M. `....
ZH-MC-GW_
ZH-MC-CW @75cd
ZH-MC�CW @95cd..
ZH-
MC -CW @135cd
2R -MC -W 15cd
DEVICES 8
87
131.
222;~
- 292-
371
TOTAL mA=
Total Wire Resistance (R )
Total Device Load, Amps (I)
Voltage Drop (E)
Voltage
0
0
O j_..
876
0
320-
1196] 14
255
22.43
1196
WL*2)*(Rift) 1.32
Total Cct Load) _ 1.20
(E=I*R) 1.57
24 - E} 22.43
DEVICES
ZH-M C W @15cd
z i -MC W ..L 30cd
ZH-MC-W @75cd
Z11 -MC -CW a(,, 95cd
ZH-MC-CW @135cd
ZR=MC=W @15cd
156 j
113 113:
195: _.....___..___.�.�
371';
;Total Wire Resistance ( R
Total Device Load, Amps
Voltage Drop (E )
EOL .Voltage
(WL*2)*(R/ft) 1.58
(Total Gct Load) 4:7'8
(E=I*R) 1.24
24 - E) 22.76
SYSTEM CALCULATIONS
THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72.
THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX
DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED.
NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION.
DUCK OVER 3' WIDE:
SAMPLE TUBE MUST GO
THRU THE DUCT AND BE
CAPPED.
TUBE OUTLET
SAMPLING
TUBE INLET
SAMPLING
AT LEAST
SIX DUCT
WIDTHS
FROM BEND
DUCT DETECTOR MOUNTING DETAIL
120VAC-6042
DEDICATED p#RCO4CY ''
NOTE FOR ADDITIONAL SPECIF1CATIONS SEE PRODUCT DOCUMENTATION.
'CONTACT RATINGS:
4.OA 0 125VAC
4.0A 0 30VDC
MI DEVICE SSTIPPIF LAST
FROM XLS CONTROL PANEL a
DR PREVIDUS ADDRESSABLE DEVICE
0
0 0
0
HTRI-R
0
0
0
0'
0'
0'
NOTE:
FOR ADDITIONAL SPECIFICATIONS
SEE PRODUCT DOCUMENTATION.
C -CABLE
C -CABLE
CEILIN
TILE
SUPPORT
BRIDGE
4" SQUARE
DEEP BOX
CEILING
HORN STROBE
/ STROBE ONLY
0000
LI
0
PAD -3
0
00°
INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX
+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + -
(-)
(+)
SPARE
j SPARE
j SPARE
DROP CEILING MOUNTING
(-)
HARD LID
CEILING
SUPPORT
BRIDGE
4" SQUARE
DEEP BOX
CEILING
HORN STROBE
STROBE ONLY
HARD LID MOUNTING
HORN STROBE & STROBE CEILING MOUNTING DETAIL
POWER SUPPLY & RELAY MODULE WIRING DETAIL
(+)
u v
HORN/STROBE
OR
STROBE ONLY
U
HORN/STROBE
OR
STROBE ONLY
HORN/STROBE
OR
STROBE ONLY
HONR STROBES & STROBES ONLY WIRING DETAIL
FROM PREVIOUS > (+)
ADDRESSABLE >
DEVICE (-)
TO NEXT
DEVICE OR
END OF LINE
NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION.
-4
EE
Ezo
(+)
TEM -1
0
WIRE DESIGNATION:
NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE
TWISTED PAIR WITH SHIELD #18 FPUFPLR RED (JACKET)
'CONTACT RATINGS:
4.0A 0125VAC
4.0A 0 30VDC
FOR ADDITIONAL SPECIFICATIONS
SEE PRODUCT DOCUMENTATION.
O
0
F
GROUND
° °0
-I I Ee I
HTRI-R 114 0-1
DRY CONTACTS TO VAV
FAN SHUTDOWN PROVIDED
BY METH/ELEC.
(+)> TO NEXT DEVICE OR
(-)
>' STOP IF LAST DEVICE
DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL
TYPICAL WIRING AND MOUNTING DETAILS
JUNCTI❑N BOX
MOUNTED ON
CEILING FLEX
JUNCTION BOX
MOUNTED AGAINST
CEILING SUPPORT
ti
0 0
0 0
TO NEXT DEVICE
CADDY BAR
SMOKE/HEAT DETECTOR
SUSPENDED
ILLUMINATED CEILING
SMOKE/HEAT DETECTOR MOUNTING DETAIL
NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION.
+322'' FF (0' C) TO 100' F (38' C)
HUMIDITY; 0-93% RELATIVE HUMIDITY,
NON -CONDENSING
HFP-11 SMOKE
DETECTOR
FROM PREVIOUS
ADDRESSABLE DEVICE
OR POWER SOURCE
DATA IN ( ) >
r>.
DATA IN (+)
DEVICE IS USTED FOR AIR VOLOCITY
APPUCATIONS OF 300-4000 FT/MIN
WHEN USED IN CONJUNCTION WITH
DUCT HOUSINGS AD -11P OR AD-11XPR
-- DB -11
STANDARD
SMOKE
DETECTOR
BASE
REAR VIEW
(-)
(+)
SMOKE DETECTOR WIRING DETAIL
HORN STROBE
OR STROBE ONLY
80" A.F.F.
(OR UNLESS
OTHERWISE
SPEC FIED)
4S DEEP BOX
> TO NEXT
> ADDRESSABLE
DEVICE
HORN STROBE & STROBE WALL MOUNTING DETAIL
FAX (206) 628-4990
TEL. (206) 622-6545
-z
LJU
)
L
J
J
w
REV. BY:
DMG
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
t, If1D All IL/DTD. C A LI_ 1
o
F-
W
o
SHOP DRAWINGS
DATE
09/25/13
2<<<<<
}
Ct
'5UALL: NUI I U (;ALE. '
DRAWN BY:
D. GARCIA
DESIGNED BY:
R. VEZZANI
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
t, If1D All IL/DTD. C A LI_ 1
•
1 SHEET
FA -02
Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
TO NEAREST
EXISTING DATA
LOOP
2C —0
r�
6-0"
COL
D,2S —0
a ru
TO NEAREST
EXISTING
SIGNALING
CIRCUIT
0
co
V r
S - a P-4111fl i JJ1J j3
d
ri
Sti
-4
46
TYP.
f
S
2 CONTINUATION
2 CONTINUATION
DO 2 CONTINUATION
5
j
RSTROO
GEILING FLM
40
41
NON -SALES AREA KEYNOTES
NON -SALES OVEN TO GEL,+" /E
VANITY LIGHT. SEE DETAIL 13/A-5
(E) RESTROOM EXHAJ'ST F - : TO MECHANICAL
42 DRMI NGS FOR NEW +, L L. TO VERIFY PIORKINO
catorrioN
13-44 N/A
45 HAN&C16 FrtS (4) AT 12"-0" A.F.F. S 1VA-8
4b
FL/ CRESCENT STRIP F * -w. ON
12-6" A.F.F,
CHAN SUFpORTS AT
4T (E) GYP BD. CEILIN,.. L.L. T' 1 -FINISH PER SCHM)LE
17008 13U ii -. n - TG1 CN Mil AT 1V-0" A.F.F.
REA BUZZER �_ r1'CCH AT 5'-0' A.F.F. REFER TO
ELECTRICAL DRA IN65
NON -SALES ENTRY ALERT CHL'^E (1) 4 V`LRELE55 rR CE.1 S
(2) FUR141SHEP BY MAJR1C . G.G. TO INSTAJL, CHIME 3 ONE
4 ONE RECOVER ON
IN SALES AREA. G.G. TO
YV/ "DING DON&" TONE d GET
REGENa5VOLUME TO MEDIUM.
48
4q
SALES AREA KEYNOTES
qaii2x4 ,th TICAL T1LE GRJD SYSTEM 5Y G.G. A
20
A.F.F. REFER TO 5rLEF>r1ATON5 MISCN
CEILING' GRID ORIGIN. CEILING TO HAVE EC3JAL SPACE21S
ACCT,* EACH 13415{N6 I"IALL
SEE DETALS SI;EET FOR TYPICAL 5PAGING OF 'CC
LIC HT FIXT1. RES
22
CEILING -MOUNTED ELECTRICAL RECEPTACLE. REFER TO
ELECTRICAL DR/WINGS a
ALL TRACK TO BE 14GUNTED 4'-3' FROM Y1ALL UNLESS24'
_ -- G'C'ri13Z E MOTU.)
23
-54.4PER SCREEN. S DETAIL 5/A-8
26
'PENDANT Ll6HT F[X1DRE, SEE ELEVATION 2/A-4 FOR
MOUNTING HEI&HT, !
START WITH 1 FALL TILE AT CENTER. at N I /Ii°1Ca RCGH kiP
21 LOCATE MAL C.tJT T1LES A5 IND'iCATE?. TYP. A..L FfTTiNG
ROOMS
25 REAR T OCR BUZZER ANNUNCfATCR A&/E CEILING TILE
aci
FITTING ROOM DOOR14EAPQR / 501111 1
-3z# ,NIA
95d
6'-O"
61..011
4-6"
- ,.:.f lkr::ii !i rtttt.E i f±LUL
TYP.
I
.. ----(— i*kl3iffrffri:fil}i2Z}.
FLAG NOTES:
FIELD LOCATE RELAY MODULE FOR
BACKGROUND MUSIC INTERFACE.
NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY
FIELD MOUNTED NEXT TO EXISTING BOOSTER
POWER SUPPLIES. AC POWER BY EC FROM
DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH
CIRCUIT.
DUCT DETECTOR, RELAY MODULE FOR FAN
SHUTDOWN & TEST SWITCH. LOCATIONS TO BE
FIELD VERIFIED BY MECHANICAL, ELECTRICAL
AND FIRE ALARM CONTRACTORS.
FIELD LOCATE TENANT JUNCTION BOX IN
BACKHOUSE CORRIDOR.
F
1
-31/+
3-4 1/7
()
S2-2
15cd
15cd
2'40 1/41-
S2-2
/4 ---
''51-7
q5cd
4-T 3/3"
`T 3/4'— I tC5
----1:3 t � Ort? r•„�,r{:�
61
1'-2 5/4"
-FRF mEa7Srrffi.T.f.f.
±2'-10 1/4" i
J
f
37-113/4"..... _.....
E ........ 52-4 t
1 bcd
S2-11
-Med
30cd
S2-10
15cd
t.
ti
ri
ti
•R
RR
an
Se
Ra
114
.■
OR
RR
RR
NU
1i
f5
aR
•5
NV
fM
a.
NV
R.
Yi
11 3/4"
eeffmfBa
GENERAL NOTES:
1) CONTRACTOR SHALL READ AND REVEW ALL EFECIFICATTONS AND PLAN'S,
;NGLFJING MECHANICAL AL L ID ELECTRICAL. SEE TASK RFSr E)9• SBILJTY
LIST FOR iNFORMAT ON ON creme FURNISHED BY MAURICE ,.
2) CONTRACTOR 94ALL FIELD VERIFY ALL miceetaNs ARP NOTIFY
MAURIGES OF ANY DISCREPANCIES.
3) FELD VERIFY ASSEMBLY REC IJIREMENTS FOR CA1aHWRAP TO DETI:RMINE
Ns E 5ARY CORD LEN4TH5 FOR CASH ARAP Y' RIN6.
4) CONTRACTOR TO RAISE AND / OR Rs...06Am E4SING SPRINKLER
HEADS A5 REWRED FOR 1VEr U6141 LOCATIONS. Lt&HT FIXW E LOCATIONS
T,E PRECEDEsICE OVER ALL OTHER CEILING BOIJIPMENT. SEE ELECTRICAL
»N66. COORDNATE Y` i LAAtit:'I,.G"RU.
5) E FI Fr.TR$CAL. DETAILS FOR ALL V' IN& LAYOUTS.
b) ALL. FIXTURE) TO HAVE LAMPS AS SFEGIFIE0 AN) SUPPLIED BY
?4k. ELECTRICAL CONTRACTOR SHALL FROZE ALL
HARDWARE, ACC�iSa . ETC., NECESSARY FOR INCCIAL INSTALLATION.
1) CONTRACTOR TO PROVIDE ALL EUFPORT FRAMING. ALL THREAD AND
IJNISTRUT ORI JAL STRUCTUT SYSTEMS TO HAN6 FIXTURES, CEILING
'MAR51104, CEILING 5'151.51, ETC,. FROM MALL STRUCTURE.
LEGENO
a
71'P.
71/2"\
1X4 FLIJGRESC,ENT TROFFER
2X4 FUUOR SCENT TROfr-T
2X4 F�
TROFFER NIGHT LIGHT
2X4 ELU0RESE)1 1T TROT -1
Y°tI E' M6. BALLAST
2X2 FLUORESCENT TROFFER
2X2 FI.U0nSCEJff TROFFER
NRI EMtERG. BALLAST
?LQ
cry-.....
._..._...___......_.i MINGLE 'TUBE FLUORESCENT STRIP
pozI.E TIi13E FLUaRaCENT STRIP
7r7ij:CIT11fll11-3 Lull" SINGLE TUBE FLUORESCENT STRIP
Y1/ emme. BALLAST
111
R.EC.E PO *4iJ6HT
TRACK MOUNT METAL HALVE
Lt6t+T FIXTURE
FIRE ALARM SYSTEM PLAN
r=.::i.
(?
f5TRO0m VANITY LIC -FIT
EXTERIOR UGHT
?-? (?)
— = -, LI&FIT TRACK et/ TR.A0C. HEAD
TYP.
0 1'
3'
S'
10'
2`
4'
PALL -MUM EMER6ENCY
LIGHT
EXIT L1 HT
- PENDANT MOUNT FIXTURE
f_) EXHAUST FAN
TRANSFORMER
ELEC. PANEL
JUNCTION SOX
EWER EATON €1' O" AFF
BUZZER ANNUNCIATOR
CONCEALED 516N OUTLET
ORIGIN POINT
POOR CHIME SYSTEM
66-2i NON-S&Ea VOOR CHHE SYS—a4
Proprietary and Confidential, Copyright 2013 by Guardian Security S
stems, Inc. All Rights Reserved
1,0
CO
FAX (206) 628-L4.990
TEL. (206) 622-654.5
1 \ L LL/"\V L/ 1 \L V 1V1 V1 YV
NO I DATE DESCRIPTION REV. BY:
1
STOREONT KEYNOTES
SISN XIS- IN EILK1+EAD FGR STORE RO T SIGN. REFER
BACKROUND PLAN PROVIDED BY:
«• OM OF BULKH . IAT 10'..11" , F. , - 4-2- T• . T10'�
•a
SHOP DRAWINGS
z''r A 0-"•F,:. ;I-
RAN AND EIEVAl1CNS ON SHEET A-5 FOR FINISHES
4
50TTOM OF DISPLAY rovon',aGFTT AT 12-0" A.F.F.
5
f:0" E1GN GM) (rrT'. OF 6) i/A-S. _
6
60" 516N &RiV GUT TO b" V'41DTH (TYP. OF b) Se 7/A -b
T "# T 6 T F1 Nur;.. D a s ` S 1 -.
".
: • C14 OF POOR IN& AT 9'-22" - .F.. R:- . TO
S 3/. -51
q-tq
,.
FLAG NOTES:
FIELD LOCATE RELAY MODULE FOR
BACKGROUND MUSIC INTERFACE.
NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY
FIELD MOUNTED NEXT TO EXISTING BOOSTER
POWER SUPPLIES. AC POWER BY EC FROM
DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH
CIRCUIT.
DUCT DETECTOR, RELAY MODULE FOR FAN
SHUTDOWN & TEST SWITCH. LOCATIONS TO BE
FIELD VERIFIED BY MECHANICAL, ELECTRICAL
AND FIRE ALARM CONTRACTORS.
FIELD LOCATE TENANT JUNCTION BOX IN
BACKHOUSE CORRIDOR.
F
1
-31/+
3-4 1/7
()
S2-2
15cd
15cd
2'40 1/41-
S2-2
/4 ---
''51-7
q5cd
4-T 3/3"
`T 3/4'— I tC5
----1:3 t � Ort? r•„�,r{:�
61
1'-2 5/4"
-FRF mEa7Srrffi.T.f.f.
±2'-10 1/4" i
J
f
37-113/4"..... _.....
E ........ 52-4 t
1 bcd
S2-11
-Med
30cd
S2-10
15cd
t.
ti
ri
ti
•R
RR
an
Se
Ra
114
.■
OR
RR
RR
NU
1i
f5
aR
•5
NV
fM
a.
NV
R.
Yi
11 3/4"
eeffmfBa
GENERAL NOTES:
1) CONTRACTOR SHALL READ AND REVEW ALL EFECIFICATTONS AND PLAN'S,
;NGLFJING MECHANICAL AL L ID ELECTRICAL. SEE TASK RFSr E)9• SBILJTY
LIST FOR iNFORMAT ON ON creme FURNISHED BY MAURICE ,.
2) CONTRACTOR 94ALL FIELD VERIFY ALL miceetaNs ARP NOTIFY
MAURIGES OF ANY DISCREPANCIES.
3) FELD VERIFY ASSEMBLY REC IJIREMENTS FOR CA1aHWRAP TO DETI:RMINE
Ns E 5ARY CORD LEN4TH5 FOR CASH ARAP Y' RIN6.
4) CONTRACTOR TO RAISE AND / OR Rs...06Am E4SING SPRINKLER
HEADS A5 REWRED FOR 1VEr U6141 LOCATIONS. Lt&HT FIXW E LOCATIONS
T,E PRECEDEsICE OVER ALL OTHER CEILING BOIJIPMENT. SEE ELECTRICAL
»N66. COORDNATE Y` i LAAtit:'I,.G"RU.
5) E FI Fr.TR$CAL. DETAILS FOR ALL V' IN& LAYOUTS.
b) ALL. FIXTURE) TO HAVE LAMPS AS SFEGIFIE0 AN) SUPPLIED BY
?4k. ELECTRICAL CONTRACTOR SHALL FROZE ALL
HARDWARE, ACC�iSa . ETC., NECESSARY FOR INCCIAL INSTALLATION.
1) CONTRACTOR TO PROVIDE ALL EUFPORT FRAMING. ALL THREAD AND
IJNISTRUT ORI JAL STRUCTUT SYSTEMS TO HAN6 FIXTURES, CEILING
'MAR51104, CEILING 5'151.51, ETC,. FROM MALL STRUCTURE.
LEGENO
a
71'P.
71/2"\
1X4 FLIJGRESC,ENT TROFFER
2X4 FUUOR SCENT TROfr-T
2X4 F�
TROFFER NIGHT LIGHT
2X4 ELU0RESE)1 1T TROT -1
Y°tI E' M6. BALLAST
2X2 FLUORESCENT TROFFER
2X2 FI.U0nSCEJff TROFFER
NRI EMtERG. BALLAST
?LQ
cry-.....
._..._...___......_.i MINGLE 'TUBE FLUORESCENT STRIP
pozI.E TIi13E FLUaRaCENT STRIP
7r7ij:CIT11fll11-3 Lull" SINGLE TUBE FLUORESCENT STRIP
Y1/ emme. BALLAST
111
R.EC.E PO *4iJ6HT
TRACK MOUNT METAL HALVE
Lt6t+T FIXTURE
FIRE ALARM SYSTEM PLAN
r=.::i.
(?
f5TRO0m VANITY LIC -FIT
EXTERIOR UGHT
?-? (?)
— = -, LI&FIT TRACK et/ TR.A0C. HEAD
TYP.
0 1'
3'
S'
10'
2`
4'
PALL -MUM EMER6ENCY
LIGHT
EXIT L1 HT
- PENDANT MOUNT FIXTURE
f_) EXHAUST FAN
TRANSFORMER
ELEC. PANEL
JUNCTION SOX
EWER EATON €1' O" AFF
BUZZER ANNUNCIATOR
CONCEALED 516N OUTLET
ORIGIN POINT
POOR CHIME SYSTEM
66-2i NON-S&Ea VOOR CHHE SYS—a4
Proprietary and Confidential, Copyright 2013 by Guardian Security S
stems, Inc. All Rights Reserved
1,0
CO
FAX (206) 628-L4.990
TEL. (206) 622-654.5
1 \ L LL/"\V L/ 1 \L V 1V1 V1 YV
NO I DATE DESCRIPTION REV. BY:
0
M
0
DESIGNED BY:
R. VEZZANI
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
InD KII I►ADCD. 6466-1
SHOP DRAWINGS
M
u)
N
rn
0
<<<<<
LU
U
c
0
W
U [co
QT
o- W
��—/�- < 0
VJ
eoc z_
CC <
Q LIJ�
CC
LL
O
07
O
c0
CV
W
LITJ
'SCALL: 1 /4--=1 -U..
DRAWN BY:
D. GARCIA
DESIGNED BY:
R. VEZZANI
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
InD KII I►ADCD. 6466-1
SHEET
FA -03
SCALE 9
71‘..A
WOOS
BUS
SMB■
SWUM
MOWN
OWNS
Bu■■
B__
Boum
WNS■
BNS■
WOOS
WOOS
ORwwUcM
U■
B WWW
*Bus
SNOW
sti3 SNOW
!WOW
OWNS
mo.
■SW■
MONS
OBS■
WORM
NNS.
VOX.
■SS■
WOW S
ONUS
SIBS
WOWS
WOOS
MOWS
WOWS
■MOB
■BWU
MOWN
MEOW
w■�s
77 :7' '7'7_-::7'
WOWS
MOWS
OVUM
;nom
■SOS
WOO
Wo
SM
MOON
BBS■
SMOON
BS
Sm
SSSS
'i't: OSB■
■SUB
mNSw
"".:'.';`OSS■
Bim■
MOO■
'Bu■
NON■
WNW■
Bo
5BB■
SSo
SSSS
.w u■
Kb= woo
r.W■
;rim■■■
WOO.
wrmw
WOO*
n ■BU■
■U■
COL
Design per NFPA 13, Ordinary Hazard Group 2
All materials to be new, U.L. listed, and F.M. approved
'All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means
All heads to be at least 6' apart
® 52 — Add Reliable Model G5-56 Standard Response 165° Concealed Pendents 1/2 x 1/2 (white)
o 5 — Add Reliable Model G Standard Response 165° Brass Uprights 1/2 x 1/2
COL
RETAINER STRAP WHERE REWIRED
IN SEISMIC AREAS
TOP BEAM/ C -CLAMP
WITH SET SCREW
3/8' ALL 'THREAD ROD
PIPE SWIVEL RING
STEEL JOIST/TRUSS
HANGER DETAIL
NTS
a
0
TED
Will lout Comments
As Noted in Red
Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau for conf orrnarIce with current City
,standards. Acceptance is subject to errors and
: )rnissions which do not authorize violations of adopted
,tandards and ordinances. The responsibility for the
�equacy of design rests totally with the designer.
till ions,
deletions or revisions to these drawings after
-:-ds date will void this acceptance and will require a •
--:submittal of revised drawings for suosequent approval.
acceptance is subiect to field test and inspection by
ne Tukwila Fre Prevention Bureau.
Date:10 13 By: Ayr, S J I
TUKWILA FIRE DEPARTMENT
Please call 206-575-4407 and
give this Fire Permit No.
3 -S-
and exact address for shut-
down
hutdown or restoration approval.
L --ILA
CROWN.
FIRE PROTECTION
INCORPORATED
P.O. BOX 12113
MILL CREEK, WASHINGTON 98082-0113
PH. (425) 481-7689
M au ri ces
\b5 \ Southcenter Mall
Tukwila, WA
DATE: q
1(013
DRAWN: ( 3'
U
MALJRICES
FIRE ALARM SYSTEM ADITION
TUKWILA, WASHINGTON
0
.hese plans ha,,c
:,',ention C�;r1:•
ndards. ACc-
sit
.Tlards
;rev n:
Iter
Tukwila Fire
current City
"�• and
adopted
tht
esuotriitti approval.
'final acceptai c- .1.210 test aid Inspection by
NOTICE
A completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testing
SHEET \U v 3ESHEET TITLE
FA -01
SYSTE
v
I\F0�
v
ATO \
8c S \GLE LINE DIAGA
v
FA -02
TYPICAL WI
A\D VVO,\TI\G 3IAGAv
S 8c CALCULATIO\S
FA -03
FRE ALAS V
PLA\
SHEET INDEX
QUANTITY
1
1
2
6
SYMBOL DESCRIPTION
MODEL
MANUFACTURER BACKBOX
MOUNTING HEIGHT
BPS
REMOTE BOOSTER
POWER SUPPLY
PAD -3
SIEMENS
PAD-3-ENCL 66" A.F.F.
TO TOP
® SMOKE DETECTOR HFP-1 1 W/ SIEMENS
(PHOTO -ADDRESSABLE) DB -11 BASE
4S DEEP
W/ 1G RING
CEILING
® DUCT DETECTOR
D
AD2-P W/ SIEMENS
HFP-11 DET.
DUCT HOUSING VERIFY
IN FIELD
TSM
-_ - .-_TEST_
DUCT DETECTOR
TSM -1
SIEMENS
1 -GANG BOX
VERIFY
IN FIELD
HT -R
INTERFACE MODULE HTRI-R
WITH RELAY
SIEMENS
4S DEEP BOX
VERIFY
IN FIELD
FIRE ALARM
DI HORN STROBE
(CEILING MOUNT)
ZH-MC-CW SIEMENS
4S DEEP BOX CEILING
FIRE ALARM
13 HORN STROBE
(WALL MOUNT)
ZR -MC -W SIEMENS
4S DEEP BOX
80" A.F.F.
TO BOTTOM
JUNCTION
❑� BOX
F.B.O.
F.B.O.
N/A
VERIFY
IN FIELD
A.F.F.
ABOVE FINISHED
FLOOR
N/A
N/A
N/A
N/A
EX
EXISTING
DEVICE
N/A
N/A
N/A
N/A
F.B.O.
FURNISHED BY
OTHERS
N/A
N/A
N/A
N/A
N/A
NOT
APPLICABLE
N/A
N/A
N/A
N/A
RED
AS BUILT
ADD OR CHANGE
N/A
N/A
N/A
N/A
GREEN
AS BUILT
REMOVE
N/A
N/A
N/A
N/A
BLUE
AS BUILT
NOTES TO CAD
N/A
N/A
N/A
N/A
SYMBOLS L EGEND
WISE SCHEDULE A\D CO\DUIT FILL CHAT
WIRE DESIGNATION
DMG
SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE
C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR` .RED (JACKET)
D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET)
P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET)
S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET)
S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET)
V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET)
V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET)
I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET)
CONDUIT FILL CHART
NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS ' AREA
TWO 600V #12 AWG THHN/THWN .244 0.D. , .0467
TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. C .0346
TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191
CONDUIT FILL
CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE
ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM
THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE.
CONDUIT SIZE MAXIMUM FILL
1/2" .12 SQUARE INCH
3/4" .21 SQUARE INCH
1" .34 SQUARE INCH
1-1/8" .60 SQUARE INCH
1-1/2" .82 SQUARE INCH
2" 1.34 SQUARE INCH
FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4.
SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END
FOR SIEMENS SYSTEM:
DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED
WITH DEVICES ADDRESS.
1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS
DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1.
2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED.
3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL
BRANCHING IS PERMISSIBLE
4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL
ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION.
5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS,
STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT)
ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION.
6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT
AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1
7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY,
TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY,
AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION.
INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED
DRAWINGS FOR "AS BUILT" PURPOSES.
9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT
SHEETS AND/OR INSTALLATION INSTRUCTIONS.
10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS
MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, \.E.C. AND NFPA 72,
SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER
SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARv1 PANEL WITHOUT
DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN.
11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT
OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS.
12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE
ACTIVATION DEVICE.
13. ALL PANEL NUVBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET.
14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROv1 THE EMERGENCY
GENERATOR.
15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER
THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL.
EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION
FOR PROTECTION DURING CONSTRUCTION.
DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL
TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72
CHAPTER 7.
16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT
AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR
OTHER BACK BOXES OF DIFFERENT CIRCUITS.
17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND
AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO
FINAL EQUIPMENT TRIM.
18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A
PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP.
19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE
OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES
AFTER COMPLETION OF THEIR INSTALLATION.
20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH
IT IS LOCATED.
21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT.
22.
23.
NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING
PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE
INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING
FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE
ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT
CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE.,
MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY.
NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE
ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES.
THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE
CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM
SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE
THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE
CABLE IS INSTALLED
NORDSTROM
3 LEVELS
171,275sf
GEv�NESCO �,HL��
0
MOM KYON
IDODIVI� I
AVON 1
rr
Moue CORA.
8
PN0 &000 „f5,9OE tO1
macys
4 LEVELS
250,407st
MAINS
00 11
oate:JO - 3 .
0,000 O1001NON
TUKWILA FIRE DEPARTMENT
Please call 206-5754407 and
give this Fire Permit No.
and exact I' {t -
down or r'cs crit cri e; pprov3I.
ut,CHO
0000100
1HE 1510 SKOP"-
5.1100 TO DO
11NDER 005 ,-
MOWN 0055 NANI
RECK IA
THE. NAND. NCA I 100001AJt
EI1 '1 L i1
50
6
10
8
OE_s1 Guy
O01LE
9.,00 N COLD
41WEIS L 1
CA1CI7lTAWS10110
SS
JOUR':EYS 0
91E1K SHOES
SHEIK SHOES
THE 000.
0 LIDS.
5500
PINION
J0W0EE
KING COUNTY 0ORARY
11.GWELERS50 00,1.0 0
11
EOISTIN
JCPenney
3 LEYEL`:
276,468sf
010000 SIJHF
MAURICES
#2800 / SPACE #408
KEY PLAN
TO NEAREST EXISTING
SIGNALING CIRCUIT
2c
120VAC, DEDICATED
(BY OTHERS)
1
4> -
FLAG NOTES:
FIELD LOCATE RELAY MODULE FOR
BACKGROUND MUSIC INTERFACE.
NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY
FIELD MOUNTED NEXT TO EXISTING BOOSTER
POWER SUPPLIES. AC POWER BY EC FROM
DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH
CIRCUIT.
DUCT DETECTOR, RELAY MODULE FOR FAN
SHUTDOWN & TEST SWITCH. LOCATIONS TO BE
FIELD VERIFIED BY MECHANICAL, ELECTRICAL
AND FIRE ALARM CONTRACTORS.
FIELD LOCATE TENANT JUNCTION BOX IN
BACKHOUSE CORRIDOR.
S2-1 S2-2 S2-3 S2-4 S2-5
15cd 15cd 30cd 15cd 15cd
S2-6 S2-7 S2-8 S2-9 S2-10 S2-11
15cd 15cd 15cd 15cd 15cd 15cd
2S
J
TO NEAREST EXISTING 2
DATA LOOP
S1-1 S1-2 S1-3' S1-4 S1-5
95cd 15cd 15cd15cd 15cd
D
I HT -R
D,I -�
I HT -R1
2I` -c
TSM
S1-6 S1-7 S1-8
15cd 95cd 95cd
EOL
S1
EOL
S2
PAID
", ?fl11
-z
co
0'
1743 IST AVE. SO., SEATTLE, WASHINGTON
FAX (206) 628-4990
TEL. (206) 622-6545
1 \L. LL1-r,V L/ 1 \L V 1 1 N./ 1 VV
NO I DATE I DESCRIPTION REV. BY:
DMG
DESIGNED BY:
R. VEZZANI
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
1 nm NIIIAARI'm. PAPP-1
SHOP DRAWINGS
M
N
rn
0
<<<<<
}
0
w
U 00
Q�
�rn
w V2 QO
0 cf)
EE =
D g cc".
Q Q2 1E2
��
u_ 0s-
0
0
CC
Z
'UALL: NUT IO SCALL
DRAWN BY:
D. GARCIA
DESIGNED BY:
R. VEZZANI
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
1 nm NIIIAARI'm. PAPP-1
•
WIRE DESIGNATION
GENERAL NOTES
SINGLE LINE DIAGRAM
2227%
Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
SHEET
FA -012
Current Load:
Standby:
Alarm:
Device Type
Qty
Amps
Total
Amps
Total
HFP-11
0:0022
0.0022
0.0023
0.002
AD2-P
1
0.0635
0.0635
0.064
0.064
HTR -R
2
0.009600
0.0096
0.021
0.042
0.0731
Amps
0.106
Amps
R
nal
a'cu
;u
Device Type
Qty
Amps
Total
Amps
Total
Main System Board
1
0.03
0.03
0.030
0.030
ZH-MC-CWc� 15CD
0.087
ZH-MC-CW @30CD
1
0.131
ZH-MC-tt11. Cc 75CD.
0.222
ZH-MC-CW @95CD
3
0.292
0.876
al -HMC -CW @135CD
0.371
ZR -MC -CW @15CD
0.069
ZR -MC- 15CD
13
0.064
0.832.
0.03
Amps
1.738
Amps
Standby. Current Load:
0.03
Amps
For 24 Hours =
0.720
Amp -hours
Alarm: Current Load:
1.738
Amps
For 5 Minute
0.146
Amp -hours
25% Derating=
1.082
Amp -hours
Total System Current Load:
1.082
Amp -hours
Notification Appliance Circuit Detail
PROJECT: MAURICES
Panel: PAD -3 BPS
Date: September 26, 2013
Wire Resistance 2.58
CURRENT TOTAL= 1977.00
-CW @15cd .M. `....
ZH-MC-GW_
ZH-MC-CW @75cd
ZH-MC�CW @95cd..
ZH-
MC -CW @135cd
2R -MC -W 15cd
DEVICES 8
87
131.
222;~
- 292-
371
TOTAL mA=
Total Wire Resistance (R )
Total Device Load, Amps (I)
Voltage Drop (E)
Voltage
0
0
O j_..
876
0
320-
1196] 14
255
22.43
1196
WL*2)*(Rift) 1.32
Total Cct Load) _ 1.20
(E=I*R) 1.57
24 - E} 22.43
DEVICES
ZH-M C W @15cd
z i -MC W ..L 30cd
ZH-MC-W @75cd
Z11 -MC -CW a(,, 95cd
ZH-MC-CW @135cd
ZR=MC=W @15cd
156 j
113 113:
195: _.....___..___.�.�
371';
;Total Wire Resistance ( R
Total Device Load, Amps
Voltage Drop (E )
EOL .Voltage
(WL*2)*(R/ft) 1.58
(Total Gct Load) 4:7'8
(E=I*R) 1.24
24 - E) 22.76
SYSTEM CALCULATIONS
THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72.
THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX
DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED.
NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION.
DUCK OVER 3' WIDE:
SAMPLE TUBE MUST GO
THRU THE DUCT AND BE
CAPPED.
TUBE OUTLET
SAMPLING
TUBE INLET
SAMPLING
AT LEAST
SIX DUCT
WIDTHS
FROM BEND
DUCT DETECTOR MOUNTING DETAIL
120VAC-6042
DEDICATED p#RCO4CY ''
NOTE FOR ADDITIONAL SPECIF1CATIONS SEE PRODUCT DOCUMENTATION.
'CONTACT RATINGS:
4.OA 0 125VAC
4.0A 0 30VDC
MI DEVICE SSTIPPIF LAST
FROM XLS CONTROL PANEL a
DR PREVIDUS ADDRESSABLE DEVICE
0
0 0
0
HTRI-R
0
0
0
0'
0'
0'
NOTE:
FOR ADDITIONAL SPECIFICATIONS
SEE PRODUCT DOCUMENTATION.
C -CABLE
C -CABLE
CEILIN
TILE
SUPPORT
BRIDGE
4" SQUARE
DEEP BOX
CEILING
HORN STROBE
/ STROBE ONLY
0000
LI
0
PAD -3
0
00°
INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX
+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + -
(-)
(+)
SPARE
j SPARE
j SPARE
DROP CEILING MOUNTING
(-)
HARD LID
CEILING
SUPPORT
BRIDGE
4" SQUARE
DEEP BOX
CEILING
HORN STROBE
STROBE ONLY
HARD LID MOUNTING
HORN STROBE & STROBE CEILING MOUNTING DETAIL
POWER SUPPLY & RELAY MODULE WIRING DETAIL
(+)
u v
HORN/STROBE
OR
STROBE ONLY
U
HORN/STROBE
OR
STROBE ONLY
HORN/STROBE
OR
STROBE ONLY
HONR STROBES & STROBES ONLY WIRING DETAIL
FROM PREVIOUS > (+)
ADDRESSABLE >
DEVICE (-)
TO NEXT
DEVICE OR
END OF LINE
NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION.
-4
EE
Ezo
(+)
TEM -1
0
WIRE DESIGNATION:
NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE
TWISTED PAIR WITH SHIELD #18 FPUFPLR RED (JACKET)
'CONTACT RATINGS:
4.0A 0125VAC
4.0A 0 30VDC
FOR ADDITIONAL SPECIFICATIONS
SEE PRODUCT DOCUMENTATION.
O
0
F
GROUND
° °0
-I I Ee I
HTRI-R 114 0-1
DRY CONTACTS TO VAV
FAN SHUTDOWN PROVIDED
BY METH/ELEC.
(+)> TO NEXT DEVICE OR
(-)
>' STOP IF LAST DEVICE
DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL
TYPICAL WIRING AND MOUNTING DETAILS
JUNCTI❑N BOX
MOUNTED ON
CEILING FLEX
JUNCTION BOX
MOUNTED AGAINST
CEILING SUPPORT
ti
0 0
0 0
TO NEXT DEVICE
CADDY BAR
SMOKE/HEAT DETECTOR
SUSPENDED
ILLUMINATED CEILING
SMOKE/HEAT DETECTOR MOUNTING DETAIL
NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION.
+322'' FF (0' C) TO 100' F (38' C)
HUMIDITY; 0-93% RELATIVE HUMIDITY,
NON -CONDENSING
HFP-11 SMOKE
DETECTOR
FROM PREVIOUS
ADDRESSABLE DEVICE
OR POWER SOURCE
DATA IN ( ) >
r>.
DATA IN (+)
DEVICE IS USTED FOR AIR VOLOCITY
APPUCATIONS OF 300-4000 FT/MIN
WHEN USED IN CONJUNCTION WITH
DUCT HOUSINGS AD -11P OR AD-11XPR
-- DB -11
STANDARD
SMOKE
DETECTOR
BASE
REAR VIEW
(-)
(+)
SMOKE DETECTOR WIRING DETAIL
HORN STROBE
OR STROBE ONLY
80" A.F.F.
(OR UNLESS
OTHERWISE
SPEC FIED)
4S DEEP BOX
> TO NEXT
> ADDRESSABLE
DEVICE
HORN STROBE & STROBE WALL MOUNTING DETAIL
FAX (206) 628-4990
TEL. (206) 622-6545
-z
LJU
)
L
J
J
w
REV. BY:
DMG
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
t, If1D All IL/DTD. C A LI_ 1
o
F-
W
o
SHOP DRAWINGS
DATE
09/25/13
2<<<<<
}
Ct
'5UALL: NUI I U (;ALE. '
DRAWN BY:
D. GARCIA
DESIGNED BY:
R. VEZZANI
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
t, If1D All IL/DTD. C A LI_ 1
•
1 SHEET
FA -02
Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
TO NEAREST
EXISTING DATA
LOOP
2C —0
r�
6-0"
COL
D,2S —0
a ru
TO NEAREST
EXISTING
SIGNALING
CIRCUIT
0
co
V r
S - a P-4111fl i JJ1J j3
d
ri
Sti
-4
46
TYP.
f
S
2 CONTINUATION
2 CONTINUATION
DO 2 CONTINUATION
5
j
RSTROO
GEILING FLM
40
41
NON -SALES AREA KEYNOTES
NON -SALES OVEN TO GEL,+" /E
VANITY LIGHT. SEE DETAIL 13/A-5
(E) RESTROOM EXHAJ'ST F - : TO MECHANICAL
42 DRMI NGS FOR NEW +, L L. TO VERIFY PIORKINO
catorrioN
13-44 N/A
45 HAN&C16 FrtS (4) AT 12"-0" A.F.F. S 1VA-8
4b
FL/ CRESCENT STRIP F * -w. ON
12-6" A.F.F,
CHAN SUFpORTS AT
4T (E) GYP BD. CEILIN,.. L.L. T' 1 -FINISH PER SCHM)LE
17008 13U ii -. n - TG1 CN Mil AT 1V-0" A.F.F.
REA BUZZER �_ r1'CCH AT 5'-0' A.F.F. REFER TO
ELECTRICAL DRA IN65
NON -SALES ENTRY ALERT CHL'^E (1) 4 V`LRELE55 rR CE.1 S
(2) FUR141SHEP BY MAJR1C . G.G. TO INSTAJL, CHIME 3 ONE
4 ONE RECOVER ON
IN SALES AREA. G.G. TO
YV/ "DING DON&" TONE d GET
REGENa5VOLUME TO MEDIUM.
48
4q
SALES AREA KEYNOTES
qaii2x4 ,th TICAL T1LE GRJD SYSTEM 5Y G.G. A
20
A.F.F. REFER TO 5rLEF>r1ATON5 MISCN
CEILING' GRID ORIGIN. CEILING TO HAVE EC3JAL SPACE21S
ACCT,* EACH 13415{N6 I"IALL
SEE DETALS SI;EET FOR TYPICAL 5PAGING OF 'CC
LIC HT FIXT1. RES
22
CEILING -MOUNTED ELECTRICAL RECEPTACLE. REFER TO
ELECTRICAL DR/WINGS a
ALL TRACK TO BE 14GUNTED 4'-3' FROM Y1ALL UNLESS24'
_ -- G'C'ri13Z E MOTU.)
23
-54.4PER SCREEN. S DETAIL 5/A-8
26
'PENDANT Ll6HT F[X1DRE, SEE ELEVATION 2/A-4 FOR
MOUNTING HEI&HT, !
START WITH 1 FALL TILE AT CENTER. at N I /Ii°1Ca RCGH kiP
21 LOCATE MAL C.tJT T1LES A5 IND'iCATE?. TYP. A..L FfTTiNG
ROOMS
25 REAR T OCR BUZZER ANNUNCfATCR A&/E CEILING TILE
aci
FITTING ROOM DOOR14EAPQR / 501111 1
-3z# ,NIA
95d
6'-O"
61..011
4-6"
- ,.:.f lkr::ii !i rtttt.E i f±LUL
TYP.
I
.. ----(— i*kl3iffrffri:fil}i2Z}.
FLAG NOTES:
FIELD LOCATE RELAY MODULE FOR
BACKGROUND MUSIC INTERFACE.
NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY
FIELD MOUNTED NEXT TO EXISTING BOOSTER
POWER SUPPLIES. AC POWER BY EC FROM
DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH
CIRCUIT.
DUCT DETECTOR, RELAY MODULE FOR FAN
SHUTDOWN & TEST SWITCH. LOCATIONS TO BE
FIELD VERIFIED BY MECHANICAL, ELECTRICAL
AND FIRE ALARM CONTRACTORS.
FIELD LOCATE TENANT JUNCTION BOX IN
BACKHOUSE CORRIDOR.
F
1
-31/+
3-4 1/7
()
S2-2
15cd
15cd
2'40 1/41-
S2-2
/4 ---
''51-7
q5cd
4-T 3/3"
`T 3/4'— I tC5
----1:3 t � Ort? r•„�,r{:�
61
1'-2 5/4"
-FRF mEa7Srrffi.T.f.f.
±2'-10 1/4" i
J
f
37-113/4"..... _.....
E ........ 52-4 t
1 bcd
S2-11
-Med
30cd
S2-10
15cd
t.
ti
ri
ti
•R
RR
an
Se
Ra
114
.■
OR
RR
RR
NU
1i
f5
aR
•5
NV
fM
a.
NV
R.
Yi
11 3/4"
eeffmfBa
GENERAL NOTES:
1) CONTRACTOR SHALL READ AND REVEW ALL EFECIFICATTONS AND PLAN'S,
;NGLFJING MECHANICAL AL L ID ELECTRICAL. SEE TASK RFSr E)9• SBILJTY
LIST FOR iNFORMAT ON ON creme FURNISHED BY MAURICE ,.
2) CONTRACTOR 94ALL FIELD VERIFY ALL miceetaNs ARP NOTIFY
MAURIGES OF ANY DISCREPANCIES.
3) FELD VERIFY ASSEMBLY REC IJIREMENTS FOR CA1aHWRAP TO DETI:RMINE
Ns E 5ARY CORD LEN4TH5 FOR CASH ARAP Y' RIN6.
4) CONTRACTOR TO RAISE AND / OR Rs...06Am E4SING SPRINKLER
HEADS A5 REWRED FOR 1VEr U6141 LOCATIONS. Lt&HT FIXW E LOCATIONS
T,E PRECEDEsICE OVER ALL OTHER CEILING BOIJIPMENT. SEE ELECTRICAL
»N66. COORDNATE Y` i LAAtit:'I,.G"RU.
5) E FI Fr.TR$CAL. DETAILS FOR ALL V' IN& LAYOUTS.
b) ALL. FIXTURE) TO HAVE LAMPS AS SFEGIFIE0 AN) SUPPLIED BY
?4k. ELECTRICAL CONTRACTOR SHALL FROZE ALL
HARDWARE, ACC�iSa . ETC., NECESSARY FOR INCCIAL INSTALLATION.
1) CONTRACTOR TO PROVIDE ALL EUFPORT FRAMING. ALL THREAD AND
IJNISTRUT ORI JAL STRUCTUT SYSTEMS TO HAN6 FIXTURES, CEILING
'MAR51104, CEILING 5'151.51, ETC,. FROM MALL STRUCTURE.
LEGENO
a
71'P.
71/2"\
1X4 FLIJGRESC,ENT TROFFER
2X4 FUUOR SCENT TROfr-T
2X4 F�
TROFFER NIGHT LIGHT
2X4 ELU0RESE)1 1T TROT -1
Y°tI E' M6. BALLAST
2X2 FLUORESCENT TROFFER
2X2 FI.U0nSCEJff TROFFER
NRI EMtERG. BALLAST
?LQ
cry-.....
._..._...___......_.i MINGLE 'TUBE FLUORESCENT STRIP
pozI.E TIi13E FLUaRaCENT STRIP
7r7ij:CIT11fll11-3 Lull" SINGLE TUBE FLUORESCENT STRIP
Y1/ emme. BALLAST
111
R.EC.E PO *4iJ6HT
TRACK MOUNT METAL HALVE
Lt6t+T FIXTURE
FIRE ALARM SYSTEM PLAN
r=.::i.
(?
f5TRO0m VANITY LIC -FIT
EXTERIOR UGHT
?-? (?)
— = -, LI&FIT TRACK et/ TR.A0C. HEAD
TYP.
0 1'
3'
S'
10'
2`
4'
PALL -MUM EMER6ENCY
LIGHT
EXIT L1 HT
- PENDANT MOUNT FIXTURE
f_) EXHAUST FAN
TRANSFORMER
ELEC. PANEL
JUNCTION SOX
EWER EATON €1' O" AFF
BUZZER ANNUNCIATOR
CONCEALED 516N OUTLET
ORIGIN POINT
POOR CHIME SYSTEM
66-2i NON-S&Ea VOOR CHHE SYS—a4
Proprietary and Confidential, Copyright 2013 by Guardian Security S
stems, Inc. All Rights Reserved
1,0
CO
FAX (206) 628-L4.990
TEL. (206) 622-654.5
1 \ L LL/"\V L/ 1 \L V 1V1 V1 YV
NO I DATE DESCRIPTION REV. BY:
1
STOREONT KEYNOTES
SISN XIS- IN EILK1+EAD FGR STORE RO T SIGN. REFER
BACKROUND PLAN PROVIDED BY:
«• OM OF BULKH . IAT 10'..11" , F. , - 4-2- T• . T10'�
•a
SHOP DRAWINGS
z''r A 0-"•F,:. ;I-
RAN AND EIEVAl1CNS ON SHEET A-5 FOR FINISHES
4
50TTOM OF DISPLAY rovon',aGFTT AT 12-0" A.F.F.
5
f:0" E1GN GM) (rrT'. OF 6) i/A-S. _
6
60" 516N &RiV GUT TO b" V'41DTH (TYP. OF b) Se 7/A -b
T "# T 6 T F1 Nur;.. D a s ` S 1 -.
".
: • C14 OF POOR IN& AT 9'-22" - .F.. R:- . TO
S 3/. -51
q-tq
,.
FLAG NOTES:
FIELD LOCATE RELAY MODULE FOR
BACKGROUND MUSIC INTERFACE.
NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY
FIELD MOUNTED NEXT TO EXISTING BOOSTER
POWER SUPPLIES. AC POWER BY EC FROM
DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH
CIRCUIT.
DUCT DETECTOR, RELAY MODULE FOR FAN
SHUTDOWN & TEST SWITCH. LOCATIONS TO BE
FIELD VERIFIED BY MECHANICAL, ELECTRICAL
AND FIRE ALARM CONTRACTORS.
FIELD LOCATE TENANT JUNCTION BOX IN
BACKHOUSE CORRIDOR.
F
1
-31/+
3-4 1/7
()
S2-2
15cd
15cd
2'40 1/41-
S2-2
/4 ---
''51-7
q5cd
4-T 3/3"
`T 3/4'— I tC5
----1:3 t � Ort? r•„�,r{:�
61
1'-2 5/4"
-FRF mEa7Srrffi.T.f.f.
±2'-10 1/4" i
J
f
37-113/4"..... _.....
E ........ 52-4 t
1 bcd
S2-11
-Med
30cd
S2-10
15cd
t.
ti
ri
ti
•R
RR
an
Se
Ra
114
.■
OR
RR
RR
NU
1i
f5
aR
•5
NV
fM
a.
NV
R.
Yi
11 3/4"
eeffmfBa
GENERAL NOTES:
1) CONTRACTOR SHALL READ AND REVEW ALL EFECIFICATTONS AND PLAN'S,
;NGLFJING MECHANICAL AL L ID ELECTRICAL. SEE TASK RFSr E)9• SBILJTY
LIST FOR iNFORMAT ON ON creme FURNISHED BY MAURICE ,.
2) CONTRACTOR 94ALL FIELD VERIFY ALL miceetaNs ARP NOTIFY
MAURIGES OF ANY DISCREPANCIES.
3) FELD VERIFY ASSEMBLY REC IJIREMENTS FOR CA1aHWRAP TO DETI:RMINE
Ns E 5ARY CORD LEN4TH5 FOR CASH ARAP Y' RIN6.
4) CONTRACTOR TO RAISE AND / OR Rs...06Am E4SING SPRINKLER
HEADS A5 REWRED FOR 1VEr U6141 LOCATIONS. Lt&HT FIXW E LOCATIONS
T,E PRECEDEsICE OVER ALL OTHER CEILING BOIJIPMENT. SEE ELECTRICAL
»N66. COORDNATE Y` i LAAtit:'I,.G"RU.
5) E FI Fr.TR$CAL. DETAILS FOR ALL V' IN& LAYOUTS.
b) ALL. FIXTURE) TO HAVE LAMPS AS SFEGIFIE0 AN) SUPPLIED BY
?4k. ELECTRICAL CONTRACTOR SHALL FROZE ALL
HARDWARE, ACC�iSa . ETC., NECESSARY FOR INCCIAL INSTALLATION.
1) CONTRACTOR TO PROVIDE ALL EUFPORT FRAMING. ALL THREAD AND
IJNISTRUT ORI JAL STRUCTUT SYSTEMS TO HAN6 FIXTURES, CEILING
'MAR51104, CEILING 5'151.51, ETC,. FROM MALL STRUCTURE.
LEGENO
a
71'P.
71/2"\
1X4 FLIJGRESC,ENT TROFFER
2X4 FUUOR SCENT TROfr-T
2X4 F�
TROFFER NIGHT LIGHT
2X4 ELU0RESE)1 1T TROT -1
Y°tI E' M6. BALLAST
2X2 FLUORESCENT TROFFER
2X2 FI.U0nSCEJff TROFFER
NRI EMtERG. BALLAST
?LQ
cry-.....
._..._...___......_.i MINGLE 'TUBE FLUORESCENT STRIP
pozI.E TIi13E FLUaRaCENT STRIP
7r7ij:CIT11fll11-3 Lull" SINGLE TUBE FLUORESCENT STRIP
Y1/ emme. BALLAST
111
R.EC.E PO *4iJ6HT
TRACK MOUNT METAL HALVE
Lt6t+T FIXTURE
FIRE ALARM SYSTEM PLAN
r=.::i.
(?
f5TRO0m VANITY LIC -FIT
EXTERIOR UGHT
?-? (?)
— = -, LI&FIT TRACK et/ TR.A0C. HEAD
TYP.
0 1'
3'
S'
10'
2`
4'
PALL -MUM EMER6ENCY
LIGHT
EXIT L1 HT
- PENDANT MOUNT FIXTURE
f_) EXHAUST FAN
TRANSFORMER
ELEC. PANEL
JUNCTION SOX
EWER EATON €1' O" AFF
BUZZER ANNUNCIATOR
CONCEALED 516N OUTLET
ORIGIN POINT
POOR CHIME SYSTEM
66-2i NON-S&Ea VOOR CHHE SYS—a4
Proprietary and Confidential, Copyright 2013 by Guardian Security S
stems, Inc. All Rights Reserved
1,0
CO
FAX (206) 628-L4.990
TEL. (206) 622-654.5
1 \ L LL/"\V L/ 1 \L V 1V1 V1 YV
NO I DATE DESCRIPTION REV. BY:
0
M
0
DESIGNED BY:
R. VEZZANI
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
InD KII I►ADCD. 6466-1
SHOP DRAWINGS
M
u)
N
rn
0
<<<<<
LU
U
c
0
W
U [co
QT
o- W
��—/�- < 0
VJ
eoc z_
CC <
Q LIJ�
CC
LL
O
07
O
c0
CV
W
LITJ
'SCALL: 1 /4--=1 -U..
DRAWN BY:
D. GARCIA
DESIGNED BY:
R. VEZZANI
DATE: 09/25/13
BACKROUND PLAN PROVIDED BY:
InD KII I►ADCD. 6466-1
SHEET
FA -03
SCALE 9
71‘..A
WOOS
BUS
SMB■
SWUM
MOWN
OWNS
Bu■■
B__
Boum
WNS■
BNS■
WOOS
WOOS
ORwwUcM
U■
B WWW
*Bus
SNOW
sti3 SNOW
!WOW
OWNS
mo.
■SW■
MONS
OBS■
WORM
NNS.
VOX.
■SS■
WOW S
ONUS
SIBS
WOWS
WOOS
MOWS
WOWS
■MOB
■BWU
MOWN
MEOW
w■�s
77 :7' '7'7_-::7'
WOWS
MOWS
OVUM
;nom
■SOS
WOO
Wo
SM
MOON
BBS■
SMOON
BS
Sm
SSSS
'i't: OSB■
■SUB
mNSw
"".:'.';`OSS■
Bim■
MOO■
'Bu■
NON■
WNW■
Bo
5BB■
SSo
SSSS
.w u■
Kb= woo
r.W■
;rim■■■
WOO.
wrmw
WOO*
n ■BU■
■U■
COL
Design per NFPA 13, Ordinary Hazard Group 2
All materials to be new, U.L. listed, and F.M. approved
'All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means
All heads to be at least 6' apart
® 52 — Add Reliable Model G5-56 Standard Response 165° Concealed Pendents 1/2 x 1/2 (white)
o 5 — Add Reliable Model G Standard Response 165° Brass Uprights 1/2 x 1/2
COL
RETAINER STRAP WHERE REWIRED
IN SEISMIC AREAS
TOP BEAM/ C -CLAMP
WITH SET SCREW
3/8' ALL 'THREAD ROD
PIPE SWIVEL RING
STEEL JOIST/TRUSS
HANGER DETAIL
NTS
a
0
TED
Will lout Comments
As Noted in Red
Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau for conf orrnarIce with current City
,standards. Acceptance is subject to errors and
: )rnissions which do not authorize violations of adopted
,tandards and ordinances. The responsibility for the
�equacy of design rests totally with the designer.
till ions,
deletions or revisions to these drawings after
-:-ds date will void this acceptance and will require a •
--:submittal of revised drawings for suosequent approval.
acceptance is subiect to field test and inspection by
ne Tukwila Fre Prevention Bureau.
Date:10 13 By: Ayr, S J I
TUKWILA FIRE DEPARTMENT
Please call 206-575-4407 and
give this Fire Permit No.
3 -S-
and exact address for shut-
down
hutdown or restoration approval.
L --ILA
CROWN.
FIRE PROTECTION
INCORPORATED
P.O. BOX 12113
MILL CREEK, WASHINGTON 98082-0113
PH. (425) 481-7689
M au ri ces
\b5 \ Southcenter Mall
Tukwila, WA
DATE: q
1(013
DRAWN: ( 3'
U