HomeMy WebLinkAboutPP - 1002 SOUTHCENTER MALL - MULTIPLE BUSINESSES - PERMITS AND PLANS1002 SOUTHCENTER MALL ASSOCIATED PERMITS 12-F-123 12-S-095 11-S-166 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East �..- PAI Tukwila, WA 98188 206-575-4407 MAY - 9 2012 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION u KW F) RE Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: \Q02_ •fv/3(L► Suite Number: Floor: Tenant Name: c\fM06,.‘0� 1 New Tenant? 2- Yes ❑ - No Property Owner's Name: VOe5 ‘e\A SS C -\-e f Mailing Address: k 1(QOk Los NneS,-ec C :1002,GCity,` Mp CONTACT PERSON -if there are questions about the submittal. Name:SFS\\Ct % of it b fl Company Name: CLrOUJr1 'W eC-S(1On/ `y)G Day Telephone: L}Z5'9 $1-7(QIff Mailing Address: POE \2--_13 PAM CS-ee 3iNk ltac6 Cit' State Zip E-mail Address: 34p� (LX CrpAA..)n , C T fl Fax Number: 42-G- \ • g(Pj S Valuation of Project (contractor's bid price): $ -77 Scope of Work (please provide detailed information): t\N& -c\re- e-for►n4er hP�S PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CER1It•Y THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING •.WNER OR AUTHORIZED AGENT: Signature: Print Name: Plan Permit App.doc Fa, Date: G1112.. SS (1L�Rtioinn Day Telephone: i -12B41 ' L i 5/14/10 TFD FP Form 8 441t531744 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: WA Site Address: 1002 C0C r T w;le% Suite Number: Floor: Tenant Name: P+ v\vot.koellcts- New Tenant? Vg - Yes ❑ - No Property Owner's Name: W Scj e �( LLC Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: ae.,t2)(4 \K e Day Telephone: C2o 6 ) Company Name: Mailing Address: f (3 1 " /*W S� Ste. r N' City State Zip E-mail Address: f Vki i t 2@ 5t-tarcitthi Se_Ctnt► i • ca V`'1 Fax Number: C- ) 34 1 t G ' Valuation of Project (contractor's bid price): $ 2/ 30 0 Scope of Work (please provide detailed information): V1 re__ Ai a -v w% A&t o(e-'eco- f0 bac_ PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: acted e:, t-- Kt` Plan Permit App.doc Date: 06 % (3 Day Telephone: C 7-067 S / 2,6g 5/14/10 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** C / King Co. Assessor's Tax No.: Site Address: 9G' <50&J j Ce{VJ-r 12/Q a / Suite Number: Floor: Tenant Name: l CI lz Q New Tenant? ❑ - Yes ❑ - No Property Owner's Name:`) V eGA \e\ A Corp. Inc Mailing Address: \\\o\ w \i: ---Aix‘ ye ?\v ,\\ r-11 uys {Ps 96tos, CA citS- City State Zip �f CONTAT PERSON -if there are questions about the submittal. / , Name: ,_).e. -.>\Cc %D I 1 O yl Day Telephone: 425 g [ 766t)? Company Name: brOl.,3 rt. FlYe_ PtD- ioY1 ,' YlC Mailing Address: ibX 12-113 1 \1 \ C Y '-e lA__VN< Gt Og2 i E-mail Address: Jess \C C� CYOLc r1TV• C1' 0Y\ City Fax Number: 42S' I - gic,P.=?..s- Valuation of Project (contractor's bid price): $'31 son.co Scope of Work (please provide detailed information): C q, -Pi YC_ 5F/' h Le r P � PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: J ^ / Print Name( eSSS) CCC P L_ %?&o7 Plan Permit App.doc Date: 7/C71/ Day Telephone: 212,5.4%/-z66 9 5/14/10 TFD FP Form 8 V FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Pinkabella 1002 Southcenter Mall Permit No.: 12-S-095 Date: May 9, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Icing 982 Southcenter Mall Permit No.: 11-S-166 Date: July 25, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods Tess than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. EQ 4'--8 1/2" CYR BD. SOFFIT 0 9'-3" A.F.F. 5-1 1/2" EQ GYP. BD. SOFFIT 0 7'-6" A.F.F. NOTE: ACCESS PANELS, IN GYP BD CEILING AS RFOUIRED; GYP. BD. SOFFIT @ 9'-0" A.F.F. OF 1 I9'-0" Iii' -o" 1 NG OF GLAZING ij GYP D. SOFFIT 0 9'-0" A.F.F. GYP. BD. so 9'-0" A.F.F. 112' CD . OF GLAZING REFLECTED CEILING PLAN SCALE: 1/4"=r--0" Design per NFPA 13— Ordinary Hazard Occupancy All materials to be new, U.L. listed, and F.M. approved All heads to be a minimum of 6' apart and to be unobstructed by any means o 19 —Add Reliable Model G4 Standard Response 165° Concealed Pendents o E — Existing upright 19 — Total o Without Comments El As Noted in Red Jig Per The Attached Letter- rSe planS have been reviewed by The Tukwila Fire evention Bureal,i for conformance with current City andards. Acceptalce is subject to errors and missions which do not authorize violations of adopted standards and ordinances. The responsibility for the -tiequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 7-).5-11 By: TUKWILA FIRE DEPARTMENT Please call 206-575-W and give ti is Fire Permit No. and exact address for shut- down or restoration approval. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS nIP BEAM/ C-CLANP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JC/ST/TRUSS HANGER DETAIL NTS PROJECT LOCATION VICINITY MAP KEY PLAN WESTFIELD SOURICENTER LEVEL 1 or I CROWN FIRE PROTECTION IN CORPORA TED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7609 DATE71q,j Icing _ 982 Southcenter Mall Tukwila, WA . beceobell DRAWN: SCALE 0 C PAID JUL 20 2011 TUKWILA FIRE TENANT LEASE LITE L (E) MALL CONCOURSE 7 INFILL Me SOFFIT TO MATCH EXISTMG — 0 PREP AREA X91 ACT -2 10-0" TENANT LEASE LINE 7 O O (E) Le SCFF'T7 O III IN 1 1 1 1 L lE) ADJACENT TENANT SPACE - No Lilo( THIS AREA 7 ~`— TENANT LEASE LINE f O 4, p_10u L (E) MALL CONCOURSE 7 REFLECTED CEILING PLAN 112" = 1'-O" INFILL Crile SOFFIT TO MATCH EXISTMG TENANT LEASE LINE (1°‘° (°(` Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 2 — Add Reliable Model G Standard Response Semi -recessed 165° Pendents 1/2 x 1/2 o E — Existing pendent no change 2 — Total SIL RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TDP BEAM/ C-CLAHP WITH SET SCREW 3/8• ALL THREAD ROD PIPE SWIVEL. RING STEEL JOIST/TRUSS HANGER DETAIL NTS 0 • 1r.r,t!':!: ut- ornmients . f' r:: r. _ h Letter by 11Tukwila Fire current City. �.rrors and ' ;. t.:1.1 t. i ze !'iolations of adopted r.:'ir1 _ '. !,. `.t.`, i;i ;Esi-xr.s=t?ility for the �!G •" o ee igner. • .c;t :� ;, r :: , _ •: .. �:.'i +>. to mese drawings after - r.r' :i: "` i ?.t yi reouare a 5,��'�!�ii`•ii t! f::...•. ' .. :r!tit- for st..:sec;uer t approval. iidi test and inspection by iie Tukwila " , ..h..nBuieau. Dte: -1 a' sv: TUKWILA FIRE DEPARTMENT Please call 205575-4407 and give this Fire Permit No. =lid exact address for shut- down cr r &ton Jon approval. CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113. MILL MEEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Pinkabella 1002 Southcenter Space 314 Tukwila, WA DATE: g. • C . t Z_ DRAWN: cfcr SCALE: o -C- l PAID g MAY -92012 24082 TUKWILA FIRE T0.0 SMSA:1122.03.06 IELD MALL AT SOUTHCENTER LORD BUILD -OUT, ENANT IMPROVEMENT NT SPACE 314 PINKABELLA Code Summary SUMMARY: - WASHINGTON STATE BUIL.DiNCG CODE Tcw STATE AMENDMENTS BUILDING CODE PECHANICAL CODE COPE TATE ENERGY CODE STATE VENTILATION AND INDOOR QUALITY CODE BUU-DMG - TO BE SUBMITTED UNDER SEPARATE PERMIT. - TO BE SUBMITTED HIDER SEPARATE PERMIT - TO BE SUBMITTED UNDER SEPARATE PERMIT - TO,BE SUMMITTED UNDER SEPARATE PERMIT - TO BE SUBMITTED UNDER SEPARATE PERMIT TH18 WORK ANP ASSOCIATED PERMIT REPRESENTS THE LANDLORD iN ,RATION FOR FUTURE TENANT. AT1ON: 14 A URBAN CENTER T I - .. vispENT SUMMARY: TOTAL SQUARE FEET - 246 SF 11 - COVERED MALL Y 1.40.0 (TABLE 1004.I.I): OCCUPANCY LOAD FACTOR - TENANT SPACE 314: 246 SF / 30 ■ 8 PERT I0i5J THE MAXIMUM OCCUPANT LOAD FOR ONE EXIT WITHIN 11$E 'M' 10:49. (TABLE 1013.1) OCCUPANCY LOAD iS 8 Y ONE EXIT IS REQWRED. THERE iS ONE EXIT PROVIDED. TOREFRONT AS THE SPACE IS OPEN TO THE MALL. EXIT IS BY CASEWORK DOOR WHICH 16 FURNISHED BY FUTURE TENANT. WIDTH - 8 (2) = 1.6 INCHES - THE FUTURE CASEWORK DOOR SHALL " WIDE, T1 RE CLEAR WiDTH 16 PROVIDED. THEREFORE OK TABLE 1016.1 - OCCUPANCY 11 MAXIMUM TRAVEL DISTANCE WITH SPRINKLER SYSTEM 18 250 TRAVEL DISTANCE WITHIN TENANT SPACE 16 LESS THAN 200 - "OK SECTION 402.444 - WITHIN EACH INDIVIDUAL TENANT SPACE INA COVERED MALL, THE MAXIMUM TRAVEL DISTANCE FROM ANY POINT TO AN EXIT OR TO THE MALL SHALL NOT EXCEED 200 FEET. TRAVEL DISTANCE TO EXl"1 FROM WITHIN TENANT SPACE 16 LESS THAN 200 FEET THEREFORE O.K. FIis RESISTANCE REQUIREMENTS: GTION 402.45) WHERE DOORWAYS TO EXITS PASSAGEWAYS SHALL BE EY I- 'a*F E DOOR ASSEMBLY THAT 18 SELF CLOSING BY TECTLON N ACCORDANCE WITH SECTION 115.4.83. SECTION 402.12 - EACH TENANT SHALL BE SEPARATED BY A FIRE PARTITION IN ACCORDANCE TO SECTION 109. CONTRACTOR SHALL COORDINATE WITH BUILDING INSPECTOR FOR ST ;UWLL BOARD ON TENANT DEMISING: WALLS THAT 1NSrTALLED GYPSUM WALL BOARD NSTALLED ON YI TNG WALL General Notes 1. ALL WORK TO BE PERFORMED IN COMPLIANCE WiTH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK 2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUM1ENTS AND CONDITIONS M THE FIELD BEFORE BEGINNING: WORK. ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF 114E ASR 14ITECT IMMEDIATELY. 3. THE ARCHITECT WILL HAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE THE CONSTRICTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS M THE EXISTING CONSTRICTION. THESE DOCUMENTS ADDU ALL KNODUN CONDITIONS, CUT IT 18 ANTICIPATED THAT HiDDEN CONDITIONS WiLL BE ENCOUNTERED DURING CONSTR.ICTiON. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES. 4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHiCH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LiPES TRUE, LEVEL, PLUME) AND SQUARE. 5 DETAILED AND/OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIirENStCNS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. 6. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED 114 CONFORMANCE WITH THE BEST PR4CTLCEB OF THE 131E0114 INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL. 1. DETAILS 6140Ut4 IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS 0THERUISE NOTED OR 814011 E. DETAILS OF CONSTRUCTION NOT FULLY S1I0UN ARE TO BE OF THE SAME NATURE AS THOSE DRAM FOR SIMILAR CONDITIONS 8. CONTRACTOR TO PROTECT EXISTING RIRNISHNGS, FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO REPLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS ENTiR'eTY TO LEVEL OF SATISFACTION OF ARCHITECT 9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OIIk4ER, INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS: CONTRACTOR TO VERIFY SEQUENCE OF WORK W1114 OUTER 10 AU. IN �11IFt R WATER RESISTANT STUDS OR FURRING CHANTIELS UNLESS NOTED OTHERWISE, SIXES AS OR'1ENSiCNED ON PLA11. PRO1IDE WATER RESISTANT (PAPERLESS) TYPE X GM IN ALL TOILET ROOMS, WAREWASI•I AND DIET AREAS 12. PROVIDE FINISH UL4LL BEHIND ALL EQUIPMENT AND CASEWORK. 13. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 14. PROVIDE ONE TYPE 5E -2A-1060 FIRE EXTINGUISHER PER 3000 SF AND NOT MORE 114AN 15 FT OF TRAVEL DISTANCE. B. THERE SHALL BE N0 BACK-TO-BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT NONRATED PARTITIONS SEPARATE OUTLETS BY 241 MN. AT FIRE RATED PARTITIONS .6. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, ,AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL CE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND/OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. 11. PROVIDE EXIT ILLLMINATION PER LOCAL CODES. 16 FURNISH AND INSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL GOVEFNING ORDINANCES AND LANDLORD CRITERIA CONTRACTOR SHALL OCTAN ALL NECESSARY PERMITS 19. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 20. FiFE SPRINKLER SYSTEM WORK AND FIRE ALA 41 SYSTEM WORK TO BE SUBMITTED U4PER SEPARATE PERMITS. 21 CONTRACTOR SHALL FUR4I814 AND INSTALL SPARE CONDUIT AND J -BOX AS REQUIRED FOR PRIMARY SIGNAGE LOCATED ON THE EXTERIOR FACADE OF ENTRY DOOR FOR TENANT SIGN TWAT 18 PROVIDED BY THE TENANT. ALL W1RI14 AND FINAL CONsEECTIONS SHALL- BE BY 1'#•E TENANT AT TENANTS EXPENSE. CONTRACTOR SHALL ROUTE WIRING THROUGH PRAMS OF STOREFRONT AS NEED TO ACCESS SIGN LOCATION. 22. CONTRACTOR SHALL FURNISH AND INSTALL SPARE CONDUIT AND J -80X AS REQUIRED FOR TENANT BLADE SIGN LOCATED AT EXTERIOR OF NEUTRAL PiER DESIGNATED BY TENANT AND LEASING COORDINATOR ALL MING AND FINAL OCNNECTIONS SHALL BE BY TENANT AT TENANTS EXPENSE. Scope of Work SCOPE OF WORK SHALL INCLUDE THE LANDLORD BUiLD OUT CF TENANT IMPROVEMENT TO AN EXISTING SPACE WITHIN *WIELD MALL At SOUTHCENTER IN PREPARATION FOR FUTURE TENANT WORK SHALL" INCLUDE, BUT 1401 BE LIMITED To: - SELECTIVE DEMOLITION OF ASSOCIATED INTERIOR FINISHES, INCLUDING BUT 1401 LIMITED TO, CEILING, LIGHTING, SPRINKLER SYSTEMS, ELECTRICAL AND MECHANICAL FIXTURES - CONSTRUCTION OF NEW TENANT NEUTRAL PIER - CONSTRUCTION OF NEW TENANT BUILIKHEAD - INTERIOR PARTITION AND ASSOCIATED FIXTURES - INSTALLATION OF SUSPENDED ACOUSTICAL CEILING TiLE Drawing Index ARCHITECTURAL TO.0 TITLE - COVER SHEET TO.1 GENERAL NOTES A1.0 DEMO PLAN, FLOOR PLAN, AND DETAILS A2.0 DEMO ELEVATION AND ELEVATIONS A3.0 DEMO RCP AND REFLECTED CEILING PLAN Separate Permits THE FOLLOWING ITEMS SHALL BE UNDER SEPARATE PERMIT SUBMITTED BY CONTRACTOR OR TENANT: - INTERIOR TENANT IMPROVEMENT - FIRE ALARM - FIRE SPRINKLER - MECHANICAL - ELECTRICAL - PLUMBING VicinitVicinity Map i S 152nd PI %,\S 1540151 • • JAti,ti Park i i ti Baker Evans tt•Wck 1 6tade Y7ay ., VS' tn.' I +r,f f • ..73tranilei Obi • WESTFIELD AT SOUTHCENTER Track Dr Project Directory OEM. UEA SOUTHCENTER LLC 2800 SOUTHCENTER SEATTLE, WA 98188 $EMIR GENERAL MANAGER ANDREW CIAiaROCHI 1 - 2062460423 F - 206244.8601 FACILITIES MANAGER: CHRISTIAN FALTENBERGER 1 - 2062460423 G - 253.6119435 CFALTENBEFSERoUESTFIELD.COM REGIONAL TENANT COORDINATOR: SCOTT PRIMER 2800 SOUTHCENTER SEATTLE, WA 98188 t 206.802.6010 F 310.6895102 C 3235183849 SPRiESTERaUSItESTFIELDCCOM1 AR:CHiTECT: SM. STEMPER ARCHITECTS, P.L.L.C. 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WASHINGTON 98106 CONTACT: WAYNE J014460N, PROJECT MANAGER T- 206.6242111 F - 206.6242913 I AYNEOSMSTEMPERCOM Site Plan TRAVEL DISTANCE TO EXIT : 175' TRAVEL DISTANCE TO PUBLIC RESTROOMS : 196' Y 4' WESTFIELD MALL AT SOUTHCENTER TENANT SPACE 314 TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. la--F-/D.3 and exact adds ss for shut- down or restoration a rJrovz 1. Without Comments Q As Noted in Red O Per The Attached Letter rase plans have been reviewed by The Tukwila Fire .: rention Bureau for c.:,n`or,nar,ce with current City --andards. Acceptance 4s subieci: to errors and .missions which do not authorize violations of adopted -zandards and ordinances. The responsibility for the -:adequacy of design rests tote;;',/ with tha designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: / -1 i By: J NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the test'. PAID JUN 13 2012 TUKWILA FIRE 1Vo iitalleki Southcenter 111A, 91452-ini 20e-218-0433 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard. 11th Floor Los Angeles. California 90025-1748 Telephone 310 478 4456 Focslmfe 310 478 4468 THIS DRAWING I5 AN EISTRIAIEHT Or SEWAGE R THE PROPERTY OP DE ARCADE= AND MAY NOT BE REPRODUCED YTNOUT THE ARCQOTECT S PQa169aH AID MESS DE PEPROOUCIION CES THE ARDNTECTS NAME ALL DESIGN NO ODEA INFORMATION BOW CH 11E ORAIMIO ARE FAR USE ON TIE SPECIFIED PRDECT OKI AID SHALE HOT BE USED ORIERMSE WTHOUT MPoITEN PFRWS90N FROM THE ARCHITECT • S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTI& AA 98106 (208) 824-2777 • FAX (208) 824-2973 WESTFIELD MALL AT SOUTHCENTER ISSUE REGISTERED I ARCHITECT SCOTT Y. SEWER STATE OF WASHINGTON ''ca ....1 � ILLI z� `W O - ce o_ a Lc O J aZ Z Q J W 03 w 00 Z 0) w <- 0 -I -§"O ISSUE PERMIT SET DATE: MARCH 28, 2012 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ TITLE - COVER SHEET A1 .0 SMSA:1122.03.06 (E) MALI. L NO WORK T1416 AREA 7 TENANT LEASE LINE • i JACENT SPAM - T1{18 AREA 7 ":7\L (E) MALL. CONCOURSE TENANT LEASE LINE ( DEMO FLOOR PLAN (E) FLOOR CLEAN OUT WASTE LINE. FIELD VERIFY LOCATION. 1/2" = 11-0T' RELOCATE (E) MALL CAMERA STROBE, ETC. TO FACE OF NEW 13ULKk1EAD. (E) E3ULKHEAD'FINS' TO BE DEMOLISHED OLISHE 1 TO BE ITS ENTIRETY, IXTURES, ETC. nA•S� .�.�if1�..• 04,1 L (E) MALL CONCOURSE MC..a LEASE LINE rwr- -- t WJ1"\\\ ,� a_ l:- - cA.'V.;t- 21-0" 9 P ;+ 1+++++ ++ ft + + + (E) FLOOR CLEAN OUT + + + TENANT LEASE LINE L (E) MALL CONCOURSE 7 1/2"=11-01' TILE BASE / L- (E) ADJACENT TENANT TO REMAIN -- J STOREFRONT TO REMAN NEUTRAL PIER DETAIL 1 1/2" = 11-0" NEUTRAL PIER DETAIL 1 1/2" = 11-0" DEMOLITION GENERAL NOTES: 1. ALL REASONABLE EFFORT HAS BEEN MADE BY THE DESIGN TEAM TO REPRESENT EXISTING CONDITIONS CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF EXISTING ITEMS, INCLUDING BUT NOT LIMITED TO, FLOORING, CEILING, LUAU. ASSEMBLY, LY, LUAU. FINISIES, ETC. IN EFFORT TO PREPARE SPACE FOR PEW CONSTRICTION. 2. AL1. ELECTRICAL, PLUMING, AND MECHANICAL SYSTEM WITHIN THE AREA OF DEMOLITION SHALL BE DEMOLISHED N THEIR ENTIRETY AND CAPPED AT THEIR RESPECTIVE PONT OF ORIGIN. FLOOR PLAN GENERAL NOTES: L DIMENSIONS PROVIDED ARE PLUSIMNIS DIMENSIONS TO BE COORDNATED WITH EXISTING PARAMETERS CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. DATA/ELECTRICAL/MECHANICAL ARE SHOILN FOR REFERENCE ONLY. DATA, ELECTRICAL, AND MECHANICAL DESIGN SHALL EE SUBMITTED BY CONTRACTOR AND PERMITTED N ER SEPARATE PERMIM 3. ALL MATERIALS SHALL BE NON-COMBUSTIBLE ANDIOR SHALL COMPLY WITH THE REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. ALSO ANY WOOD COMPONENTS USED SHALL. EE FIRE RETARDANT TREATED WOOD. (IBC 402.13.4, 602, 603, 4 2604) 4. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS DELL AS LEASE LINES PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD FOR CLARIFICATION. 5. CONTRACTOR SHALL PROTECT MALL COMMON AREA AT AU. TIMES AND NO CONSTRUCTION MATERIAL, DEERS, WORD, OR DUST SHALL ENTER OR 8E WITHIN MALL COM:'1G'N AREA. 6. CONTRACTOR SHALL PRIME ALL NEULY CONSTRUCTED WALLS, NEUTRAL PIERS, SOFFITS, AND BULKHEADS TO LEVEL 4 FINISH. NEUTRAL PIER AND MALL CONCOURSE AREAS TO BE PAINTED TO LEVEL 4 FN1814. 1. AREAS DESIGNATED AS 140 WORK THIS AREA' SHALL REMAIN AS CURRENT CONDITION. THE SPACE SHALL MEET THEE REQUIREMENTS SET FORTH BY LOCAL JURISDICTION FOR A VACANT SPACE. SPRINKLER SYSTEM AND FIRE ALARM SHALL PROVIDE COVERAGE FOR THE VACANT SPACE AND NEW LANDLORD STORACIE AREA AS REQUIRED. 8. CONTRACTOR SHALL CAP AND TERMNATE ALL EXISTING UTILITIES AND SERVICES DESIGNATED TO BE DEMOLISHED, AT FINISH FLOOR LEVEL FOR AU. SERVICES AND UTILITIES WITHIN THE FLOOR BLAB S. CONTRACTOR SHALL CAP AND TERMINATE AU. EXISTNG UTILITIES AND SERVICES DESIGNATED TO 8E DEMOLISHED ABOVE FINISH FLOOR LEVEL AT ITS PONT OF ORIGIN. 10. CONTRACTOR SHALL FURNISH AND INSTALL FIRE ALARM, SMOKE DETECTORS, AND SPRINKLED AS REQUIRED BY LOCAL JURISDICTION HAVING AUTHORITY. 11. CONTRACTOR SHALL PROVIDE REQUIRED MECHANICAL (HVAC) AND ELECTRICAL SERVICE TO AREA WPER SEPARATE FER't1T. DEMO FLOOR PLAN KEY NOTES: OUTLINE OF AREA DESIGNATED TO BE DEMOLISHED BY CONTRACTOR IN PREPARATION AND ACCESS FOR DEMOLITION OF WALL ASSEMBLY AND CONSTRUCTION OF NEW TENANT DEMISING LU4LL. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DEMOLISH AND REMOVE ANY OBSTRUCTIONS THAT PREVENT DEMOLITION AND CONSTRUCTION Acrivrry.W Wow SHALL INCLUDE, BUT NOT BE LIMITED TO, WALL$ CASElUOR , COLUMN COVER'S, FIXTURES, FLOORING, BASE, AND ALL FNI81.E8, AS REQUIRED FOR DEMOLITION AND CONSTRUCTION OF DESIGNATED 1114LL ASSEMBLY. (E) FLOOR FINISHES TO BE DEMOLISHED N THEIR ENTIRETY, INCLUDING BUT NOT LIMITED TO, TILE, WOOD FLOOR, VCT, CARPET, ADHESIVES, GROUT, ETC. (E) MALL CONCOURSE TILE TO BE DEMOLISHED. ( TO BE S * N ITS Y SHALL TOP TRACK, METAL STUD ATA, AND MECHANICAL IRETY, INCLUDING BUT NOT ®(E) TENANT DEMISING WALL TO REMAIN. CONTRACTOR SHALL AND PREP EXISTING GUS TO LEVEL 4 FNISH. FURNISH AND INSTALL ULASTE LINE FROM EXISTING MALL WASTE LINE TO BACK OF TENANt SPACE. SAWCT/TRENCN AND PATCH CONCRETE AS REQUIRED TO INSTALL WASTE LINE WITH REQUIRED SLOPE TO DRAIN AND CON'ECT TO (E) LINE. 61115 UP WITHIN TENANT SPACE AT 3 COMP SIN( AND MOP SINK ® (E) GRAPHIC TO BE DEMOLISHED IN ITS ENTIRETY. r UJ4LL TYPES QTY WALL TYPE - EXISTING (I -HR RATED) UL DESIGN • LI -465 - (E) 5/8" TYPE X GWS - (E) 6' METAL STUD FRAMING - (E) 5/8" TYPE X GUS AT TENANT SPACE - L14LL SHALL CONTINE UP TO STRUCTURE W/ GtLe STOPPING 6' FROM STRUCTURE 1. AOR SHALL VERIFY THE STATUS OF EXISTING WIAU. ASSEMBLY TO MEET I -14R RATED ASSEMBLY REQUIREMENT. 2. CONTRACTOR SHALL PATCH AND REPAIR GUS AS REQUIRED TO RECEIVE LEVEL 4 FINISH. 2 WALL TYPE - EXISTING (I -HR RATED) UL DESIGN • U-465 - 5/8' TYPE X GWS - 6' METAL STUD FRAMING - 5/8' TYPE X GUS AT TENANT SPACE - WALL SHALL CONTINUE UP TO STRUCTURE W/ 6116 STOPPING 6" FROM STRUCTURE 3 (114LL TYPE - INTERIOR PARTITION - 5/8" TYPE X GUS - 3 5/8' METAL STUD FRAMING - 5/8" TYPE X GIS AT TENANT SPACE LATE: CONTINUE UP TO 6' ABOVE CEILING TILE AND GRID 1. TYPE GENERAL NOTES: 1. CONTRACTOR SHAD. VERIFY EASING CONDITIONS, INCLUDING BUT NOT LIMITED TO METAL STUD WIDTH AND THICKNESS, HEW OF STIED FRAMING, CONDITION OF EXISTING GUS. 2. CONTRACTOR SHALL PREP AND PRIME ALL NEW TENANT SPACE GUS AND &TORAC:E AREA GWS TO LEVEL 4 FN18H. 3. CONTRACTOR SHALL PREP AND PAINT ALL MALL CONCOURSE (NEUTRAL PIERS, BULKHEAD, ETC, RELATED AREAS TO LEVEL. 4 FINISH. COLOR TO BE DETERMINED BY UESTFIELD. 4. CONTRACTOR SHALL MAINTAIN RATING OF ALL 1-14OUR RATED ASSEMBLES - EXISTING AND NEW ASSEMBLIES - WITHN AREA Of WOIdM. J (E) MALL CONCOURSE TILE TO BE DEMOLISI4ED. FURNISH AND INSTALL TILE TO MATCH (E) MALL CONCOURSE TILE. SHADED AREA SHALL REPRESENT THAT AREA DESIGNATED TO BE DEMOLISHED IN ORDER FOR CONSTRUCTION OF NEW DEMISING WALL. DEMOLITION SHALL INCLUDE BUt NOT BE LIMITED TO U14LL6, COLUF'14 COVED, FIXTURES, FLOORINS, BASE, AND ALL FINISHES ASSOCIATED WINN THE AREA OF DEMOLITION IN PREPARATION OF NEW CONSTRUCTION. FLOOR PLAN KEY NOTES: 01 FURNISH AND INSTALL 111487E UNE FROM EXISTING MALL WASTE LINE TO BACK OF TENANT SPACE. SAWCUT/TRENCI•I AND PATCH CONCRETE AS REQUIRED TO INSTALL WASTE LINE WITH REQUIRED SLOPE TO DRAIN AND CONNECT TO (E) UNE. STUB UP WITHIN TENANT SPACE AT 3 COMP SINK AND MOP SINK AND FUTURE ('REP BIN( (E) TENANT DEMISING UAL!. TO REMAIN. CONTRACTOR SHALL. PRIME AND PREP 02r..7.Y EXISTING GUTS TO LEVEL 4 FINISH. "CONTRACTOR SHALL CLEAN, PREP AND PREPARE CONCRETE SLAB IN PREPARATION FOR FLOOR FINISHEE6 BY TENANT. O FURN CONTRACTOR SHALL ISH AND INSTALL FLOOR TILE TO MATCH EXISTING CONCOURSE TILE IN SIRE, SHAPE, AND THICKNESS. O FSR FURNISHED AND INSTALLED BY TENANT. ELECTRICAL DESIGN BUILD CONTRACTOR SHALL COORDINATE POUER REQUIREMENTS WALL MOUNTED SINK : RE - DESIGN BUILD CONTRACTOR 0 EXISTING WALL ASSEMBLY TO REMAIN. CONTRACTOR SHALL PATCH AND REPAIR ANY HOLES, DEFECTS IN WALL ASSEMBLY AND PRIME TO LEVEL 4 FINISH. 0 EXISTING DOOR TO REMAIN. O 4' HIGH TILE BASE (4" X 8" CHARRED OAK - MOUNTAIN QUARRY II- BY DALTILE) lICS�[C� Sou th cen ter 08121-1211 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard. llth Floor Loa Angeles, Ca@fomia 90025-1748 Telephone Facimile 310 478 44468 TRS GRAYING IS AN PfSIRNENT OF SLRMCE. IS THE PROPERTY OF TIB AROOTECT AND MAY NOT BE REPRODUCED 111114OUT THE AROOTECI'S FE OS% Ale UK= 1IE REFRO011CIUC I GAMES 1HE AROPTECTS NAME. NI DEEM NO OMR OFORIATION Slaw ON TIE OIUYNO ARE FOR UM ON OTHERWISEWUTT MITTE7NPECIFIED EN PERI FROM DE"° ARCHITECT T BE USE) ■ S.M. STEMPER ARCHITECTS Professional Limited Liability Company 4000 DRLRIDGE WAY SW SUITS 200 • SEATTLE, WA 98106 (208) 824-2777 • FAX (208) 824-2973 4220 REGISTERED ARCHITECT LSCOTT E OF WASNINGTONJ ISSUE /\MAY 2, 2012 ISSUE PERMIT SET DATE: MARCH 28, 2012 PROJECT ARCHITECT WEJ PROJECT MANAGER DEMO PLAN, FLOOR PLAN, AND DETAILS