Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 982 SOUTHCENTER MALL - CHOCOLATE BAR - PERMITS AND PLANS
982 SOUTHCENTER MALL ASSOCIATED PERMITS 11-F-199 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. ICING FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FIRE ALARM SYSTEM PLAN SHEET INDEX 1,3,4 Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Accept-;r;ce is subject to errors and omissions which do not authorize violations of adopted standards and .,rdinances. The responsibility for the ,,,oequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after <f!is date will void t<<<s acceptance and wlll require a f esubmittai of revised drawings for subsequent approval. nal acceptance is subject to field test and inspection by ,e Tukwila Fire Prevention Bureau. q-ffi( Bv: TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. /1 -F --/q and exact address for shut- down hutdown or restoration approval. WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 2 2 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT ®D DUCT DETECTOR AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD HTR -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD Exi FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS ,71,27,_. I :�,•:, l C-R, JAL' SEARS macy LEVEL 2 5C.4i:7 f 0.:,..,: ,.gin 7L'F_R 4 M.L. gIT CE ICING SPACE #432, 2800 :rip 7 J ar,t CAN, ri!ARV JCPenney 27G,4Gsf tti PAID AUG 31 2011 TUKWILA FIRE - /73d( Dov is V) O` 0 z Lu 1- LU Cf) 6 (1) ui 0) 14) r\ FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I 0 DESCRIPTION SHOP DRAWINGS DATE 08/30/11 2 «<l<< cc LL J 4 ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 08/30/ 11 BACKROUND PLAN PROVIDED BY: \OB NUMBER: SHEET WIRE DESIGNATION GENERAL NOTES SITE PLAN FA -O Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6CHZ �I DEDICATED EMERGENCY ll NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC PlthmsgaliinV TO NEXT ADDRESSABLE (+ DEVICE STOP W LAST DEVICE s - FROM XLS CONTROL PANEL CE DR PREVIOUS ADDRESSABLE DEVICE - O 0 O 1] 0 HTRI-R O O 0 O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 00 00 El PAD -3 oo0 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - (-) (+) (-) (+) SPARE SPARE SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) 07 - NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPLIFPLR RED(JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O 0 r 1— GROUND L a i© © 0 0 111 (-) 0 (+)> TO NEXT DEVICE OR (-) D STOP IF LAST DEVICE DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. HTRI-R DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL u u HORN/STROBE OR STROBE ONLY r1 ^ v v HORN/STROBE OR STROBE ONLY + u HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERPTIN TEMPERATURE: +32' F (0' C) TO 100' F 3g C) HUMIDITY: O-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -) FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LI CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0; 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 RELEASE/REVISIONS REV. BY: o m 0 DESCRIPTION SHOP DRAWINGS w F- o o co 0 z CC<C< (SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 08/30/ 11 BACKROUND PLAN PROVIDED BY: MOB NUMBER: J i cA-02SHHEEET r� I� ry dp� 1, ? d , i Y FVi, 1 Y db A SsSwN 4S t A i i{{Yt �4} y} i `m + iE, F�f F N Yv1dJ'", 1 I. F. X.,,?� ��,. w� Y 46''' , ti, y'f " t ep � v . .d kg., `�*��.MI,�F�X u� N �8n R 4 I 7d � #�**�,r k }, DESCRIPTION SHOP DRAWINGS y �/,�y4 ' ""��V^T"'� " , 'tl. ,'tthR ✓��, Current Load: 08/30/11 Standby: Alarm: z <a«< Device Type Qty Amps Total Amps Total NFP -11 1 0.0022 0.0022 0.0023 0.002 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R. 2 0.009600 0.0096 0.021 0.042 SET -MC -C @30CD 1 0.131 SET -MC -C @7 C 0.222 SET -MC -C @95CD 1 v 0.0731 Amps 0.106 Amps ?, F ?k,ka ',3,, lrs'}i .7}3,, 4. t�, •,;P.,, �:.ds&,, a :,p ., A:?w+"rptr^;.Y, Ib�,,^42 j�x 1',, •yk,�,� .t�"'.,,, rai, ,Pe,.xS,k E.., t. ��tfw „i rp. r„ 'i' 'y� � ��'� 'Ww "K. M 4 P I rr %,i ',,dt �y a �"yr �',%;F t Ilan• tl � w Y 1+. .F .F. ! + ! { : 1 I. F. X.,,?� ��,. w� Y f� „N d ,y,, , 0 DESCRIPTION SHOP DRAWINGS y �/,�y4 ' ""��V^T"'� " , 'tl. ,'tthR ✓��, v r 4e 08/30/11 z <a«< Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET-IUIC-C CD 0.0875 SET -MC -C @30CD 1 0.131 SET -MC -C @7 C 0.222 SET -MC -C @95CD 1 0.292 0.292 SET -MC -C ©110CD 0.259 ZR -MC @15CD 3 0.069 0.207 ZH-MC @15CD 1 0.087 0.087 ZH-MC @95CD 1 0.292 0.292 0.03 Amps 0.908 Amps Standby. Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.908 Amps For 5 Minutes=. 0.076 Amp -hours 25% Derating: 0.995 Amp -hours Total System Current Load: 0.995 Amp -hours Notification Appliance Circuit Detail PROJECT: ICING [wire Resistance Panel: PAD -3 POWER SUPPLY (EXISTING) Date: 2.58 August 30, 2011 CURRENT TOTAL=1 517.00 0 ISET-MC-C @15CD SET -MC -C @30C© SET -MC -C @75CD SET -MC -C @95CD ZR -MC @110CD ZR -MC @15CD ZH-MC @75CD 1ZH-MC @95CD DEVICES= 4 131 222 01 292 0 259 Y_----_,- 01 69 -"---o1 69 138 871 871 292 � : 292 a: TOTAL mA— 5171 12 !Total Wire Resistance (R ) Total Device Load, Amps(I) ;Voltage Drop (E ) EOL Voltage (. WL* 2)*(Rift) 1 Cct Load) :, 0.5� E= I * R) 1.03 24 - E) 22.97 SYSTEM CALCULATIONS TO EXISTING SIGNALING DEVICES (THINGS REMEMBERED) 120VAC, DEDICATED ( BY OTHERS) t BPS EX S1-1 S1-2 S1-3 S1-4 15cd 15cd 95cd 15cd (LOCATED ALONG HALLWAY) EOL S1 TO NEAREST EXISTING DATA LOOP FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. cO 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 08/30/11 z <a«< Qco co 21.4117) r H <O) to cc 0 w H WZ U (1)=Q cc god wa w cc cm t1 I— r dC CC w z w J z C 0 z co z 0 I— U Q w Cly tJ3 SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 08/30/11 BACKROUND PLAN PROVIDED BY: JOB NUMBER: SINGLE LINE DIAGRAM SHEET (� FA -03 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved TO NEAREST EXISTING DATA LOOP EOL S1 (HTR -RI s S1-4 15cd r -el S1-3 L_ 95cd [` T r —. o AHU S/_ r FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS Lu 1--- 08/30/11 <,,, 2 <<‹* co Z co < 0) z CE < W O {� w W z : UcC� god W o cc ND LL 1- CC �CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 08/30/1 1 BACKROUND PLAN PROVIDED BY: `J0B NUMBER: ( SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved J 982 SOUTHCENTER MALL ASSOCIATED PERMITS 11-F-199 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. ICING FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FIRE ALARM SYSTEM PLAN SHEET INDEX 1,3,4 Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Accept-;r;ce is subject to errors and omissions which do not authorize violations of adopted standards and .,rdinances. The responsibility for the ,,,oequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after <f!is date will void t<<<s acceptance and wlll require a f esubmittai of revised drawings for subsequent approval. nal acceptance is subject to field test and inspection by ,e Tukwila Fire Prevention Bureau. q-ffi( Bv: TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. /1 -F --/q and exact address for shut- down hutdown or restoration approval. WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 2 2 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT ®D DUCT DETECTOR AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD HTR -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD Exi FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS ,71,27,_. I :�,•:, l C-R, JAL' SEARS macy LEVEL 2 5C.4i:7 f 0.:,..,: ,.gin 7L'F_R 4 M.L. gIT CE ICING SPACE #432, 2800 :rip 7 J ar,t CAN, ri!ARV JCPenney 27G,4Gsf tti PAID AUG 31 2011 TUKWILA FIRE - /73d( Dov is V) O` 0 z Lu 1- LU Cf) 6 (1) ui 0) 14) r\ FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I 0 DESCRIPTION SHOP DRAWINGS DATE 08/30/11 2 «<l<< cc LL J 4 ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 08/30/ 11 BACKROUND PLAN PROVIDED BY: \OB NUMBER: SHEET WIRE DESIGNATION GENERAL NOTES SITE PLAN FA -O Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6CHZ �I DEDICATED EMERGENCY ll NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC PlthmsgaliinV TO NEXT ADDRESSABLE (+ DEVICE STOP W LAST DEVICE s - FROM XLS CONTROL PANEL CE DR PREVIOUS ADDRESSABLE DEVICE - O 0 O 1] 0 HTRI-R O O 0 O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 00 00 El PAD -3 oo0 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - (-) (+) (-) (+) SPARE SPARE SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) 07 - NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPLIFPLR RED(JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O 0 r 1— GROUND L a i© © 0 0 111 (-) 0 (+)> TO NEXT DEVICE OR (-) D STOP IF LAST DEVICE DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. HTRI-R DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL u u HORN/STROBE OR STROBE ONLY r1 ^ v v HORN/STROBE OR STROBE ONLY + u HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERPTIN TEMPERATURE: +32' F (0' C) TO 100' F 3g C) HUMIDITY: O-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -) FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LI CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0; 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 RELEASE/REVISIONS REV. BY: o m 0 DESCRIPTION SHOP DRAWINGS w F- o o co 0 z CC<C< (SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 08/30/ 11 BACKROUND PLAN PROVIDED BY: MOB NUMBER: J i cA-02SHHEEET r� I� ry dp� 1, ? d , i Y FVi, 1 Y db A SsSwN 4S t A i i{{Yt �4} y} i `m + iE, F�f F N Yv1dJ'", 1 I. F. X.,,?� ��,. w� Y 46''' , ti, y'f " t ep � v . .d kg., `�*��.MI,�F�X u� N �8n R 4 I 7d � #�**�,r k }, DESCRIPTION SHOP DRAWINGS y �/,�y4 ' ""��V^T"'� " , 'tl. ,'tthR ✓��, Current Load: 08/30/11 Standby: Alarm: z <a«< Device Type Qty Amps Total Amps Total NFP -11 1 0.0022 0.0022 0.0023 0.002 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R. 2 0.009600 0.0096 0.021 0.042 SET -MC -C @30CD 1 0.131 SET -MC -C @7 C 0.222 SET -MC -C @95CD 1 v 0.0731 Amps 0.106 Amps ?, F ?k,ka ',3,, lrs'}i .7}3,, 4. t�, •,;P.,, �:.ds&,, a :,p ., A:?w+"rptr^;.Y, Ib�,,^42 j�x 1',, •yk,�,� .t�"'.,,, rai, ,Pe,.xS,k E.., t. ��tfw „i rp. r„ 'i' 'y� � ��'� 'Ww "K. M 4 P I rr %,i ',,dt �y a �"yr �',%;F t Ilan• tl � w Y 1+. .F .F. ! + ! { : 1 I. F. X.,,?� ��,. w� Y f� „N d ,y,, , 0 DESCRIPTION SHOP DRAWINGS y �/,�y4 ' ""��V^T"'� " , 'tl. ,'tthR ✓��, v r 4e 08/30/11 z <a«< Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET-IUIC-C CD 0.0875 SET -MC -C @30CD 1 0.131 SET -MC -C @7 C 0.222 SET -MC -C @95CD 1 0.292 0.292 SET -MC -C ©110CD 0.259 ZR -MC @15CD 3 0.069 0.207 ZH-MC @15CD 1 0.087 0.087 ZH-MC @95CD 1 0.292 0.292 0.03 Amps 0.908 Amps Standby. Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.908 Amps For 5 Minutes=. 0.076 Amp -hours 25% Derating: 0.995 Amp -hours Total System Current Load: 0.995 Amp -hours Notification Appliance Circuit Detail PROJECT: ICING [wire Resistance Panel: PAD -3 POWER SUPPLY (EXISTING) Date: 2.58 August 30, 2011 CURRENT TOTAL=1 517.00 0 ISET-MC-C @15CD SET -MC -C @30C© SET -MC -C @75CD SET -MC -C @95CD ZR -MC @110CD ZR -MC @15CD ZH-MC @75CD 1ZH-MC @95CD DEVICES= 4 131 222 01 292 0 259 Y_----_,- 01 69 -"---o1 69 138 871 871 292 � : 292 a: TOTAL mA— 5171 12 !Total Wire Resistance (R ) Total Device Load, Amps(I) ;Voltage Drop (E ) EOL Voltage (. WL* 2)*(Rift) 1 Cct Load) :, 0.5� E= I * R) 1.03 24 - E) 22.97 SYSTEM CALCULATIONS TO EXISTING SIGNALING DEVICES (THINGS REMEMBERED) 120VAC, DEDICATED ( BY OTHERS) t BPS EX S1-1 S1-2 S1-3 S1-4 15cd 15cd 95cd 15cd (LOCATED ALONG HALLWAY) EOL S1 TO NEAREST EXISTING DATA LOOP FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. cO 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 08/30/11 z <a«< Qco co 21.4117) r H <O) to cc 0 w H WZ U (1)=Q cc god wa w cc cm t1 I— r dC CC w z w J z C 0 z co z 0 I— U Q w Cly tJ3 SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 08/30/11 BACKROUND PLAN PROVIDED BY: JOB NUMBER: SINGLE LINE DIAGRAM SHEET (� FA -03 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved TO NEAREST EXISTING DATA LOOP EOL S1 (HTR -RI s S1-4 15cd r -el S1-3 L_ 95cd [` T r —. o AHU S/_ r FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS Lu 1--- 08/30/11 <,,, 2 <<‹* co Z co < 0) z CE < W O {� w W z : UcC� god W o cc ND LL 1- CC �CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 08/30/1 1 BACKROUND PLAN PROVIDED BY: `J0B NUMBER: ( SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved J