PP - 984 SOUTHCENTER MALL - HOT TOPIC INC - PERMITS AND PLANS
984 SOUTHCENTER MALL ASSOCIATED PERMITS 18-F-138 14-F-222 10-F-059 18-S-122 14-S-219 10-S-053 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: "ID►"[ ±:ra*C.e.A\G Tenant Name: Mobi Property Owner's Name: tIP eAcklWoli)- Mailing Address7P4 V l King Co. Assessor's Tax No.:Q2b2.1-11(Y b 4440 Suite Number: Floor: New Tenant? ❑ - Yes S .- No CONTACT PERSON -if there are questions about the submittal. Named , we€, c C»C\ vv� Company Namea Ac (c CQX\ 0 Mailing Address:'1Uc? \ * -M J E-mail Address:A6C�1G1(0Ifi Qiaidla �,C(� Mt V TCET III numberC2-1 Q2 City State Zip Day Telephone: ...(1-0) (Qi — 384tp City • WYi1 Fax Number: ontractor's City of Tukw. Business License number: \NI agt3( State Zip Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ ob Scope of Work (please provide detailed information): caC device, aCt.rm Sljs•ke)rr,, addun5 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R OR AUTHORIZED AGENT: Signature: Print Nam Plan Permit App.doc Day Telephone: Date: i t tS oc 1p1 -3g 8/22/14 TFD FP Form 8 44iitt*W144 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.:__ Site Address: C (>k / ",S.o 500ve I\t'r )"Y\\\ Suite Number: 49 0 Floor: Tenant Name:`QA_f O 1M New Tenant? ❑ - Yes ❑ - No �/ Property Owner's Name: V �� , - \'\A rWY ' l ri�iT Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: 3ef-D‘C Q r&o.) fl' c' 1 Day Telephone: LPS ' _ 1 p 1 7WOG Company Name: CyOki,'111 (Inc Mailing Address: & i2__\\� ' YY) 1 1, C &R °2— E -mail Address: 'e S3V 1 O Q C YOUR Yt v • (CY) Fax Number: 42. - 4Li J Total number of new/relocated devices or sprinkler heads: { 1� Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): sysodi-Aef \neock PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O/R�AUTHORIZED AGENT: Signature: (•Ss\an` cX _ c\ICAAA•g42n 36CS\CA 19111W1) Print Name: Plan Permit App.doc Day Telephone: Date: (9 1241 � 9 1/2/13 TFD FP Form 8 CITY OF TUICWIILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review **PLEASE PRINT** SITE LOCATION Site Address: q51/ E(501-IvinW rna Suite Number Floor Tenant Name: / (/ I °i New Tenant? ❑ - Yes Q - No Property Owner's Name: (,)Q 51'-6 Q 1d t t ( caloppuloa/ (,(itl Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. King Co. Assessor's Tax No.: Name: 1 -fra� Day Telephone: 46744/ -764 Company Name: C 17.t pvo f W?nn 1 Yl C Mailing Address: t" o 64 / 2, 1 3 m/ (/ n v/ 9) (i2 City E-mail Address: Fax Number. Contractor's City of Tukwila NICET 1II number. Business License number: Total number of new/relocated devices or sprinkler heads: x Valuation of Project (contractor's bid price): $ f "J ) -i •� Scope of Work (please provide detailed information): kd fl vacls rel DC -rrt q hjx 6 S' PERMIT APPLICATION NOTES 9 valise of Coastraction — In all cases, a value of construction amount should be entered by the applicant This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. State Zip Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its i or ifthe work authorized en the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause deiuonsttated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZE© TO APPLY FOR THIS PERMIT. BUILDING OWNER OR1A/Uj TH�ORIZED AGENT: 111/ r , w Sianature�� `` Date: Print Name: c-IJ� I� -qua u,% 1 r c e V / Day-Tdeoone: Y-57 / ` 7 U! Plan Permit App_doc 822/14 TFD FP Form 8 ' SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application • accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address: 984/986 South Center Mall, Tukwila, 98188 Suite Number: 42°1 Tenant Name: Soles Shoes New Tenant? ❑ -Yes 0 - No Property Owner's Name: Hinkle Construction Mailing Address: 1905 N Williams, Mesa AZ 85203 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Casey Walsh Day Telephone: 206.331.6206 Company Name: Guardian Security Systems Mailing Address: 1743 First Ave South, Seattle, WA 98134 E-mail Address: cWalsh@guardiansecurity.com Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 2000 City State Zip Fax Number: 206.628.4e90 Scope of Work (please provide detailed information): Adding ci devices to an existing fire alarm system PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name.Casey Walsh Plan Permit App.doc Date: 09/25/2014 Day Telephone: 206-454-9652 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Sole Shoes 984 Southcenter Mall Permit No.: 14-S-219 Date: October 2, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: T -Mobile 984 Southcenter Mall Permit No.: 18-S-122 Date: June 22, 2018 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2' inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Shiek Shoes 984 Southcenter Mall Permit No.: 10-S-053 Date: April 1, 2010 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2007 Edition. FI ALARM SYSTEM ADDITI TUKWILA, WASHINGTON SHEET \UMBE SHEET TITLE FA -01 SYSTEM \FORMATIO\ FA -02 TYPICAL WI I\G AND. MOUNTING DETAILS EA -03 SYST V CALC U LATI O \ S AN D SINGLE LINE DIAGAV FA -04 ERE ALAS vl SYSTEM P _AN SHEET INDEX 'tp' Without Comments o As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: i By: WI 'WXWILA FIRE. DEPARTMENT' Please call 206-575-4407 and give. this Fire,Permit No. nd exact address for shut - :own or re.oration approval. SCHEDULE A \D CO\DUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPUFPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPUFPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPUFPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JJRISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVIIE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY E 3 2 2 1 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY E (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 3 FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TS M -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A Ni A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVEL r3 urs • ...27Esi r_. T -MOBILE SUITE 440 macy 3 SEARS 7 T SITE PLAN PAD JUN 13 2018 TUKWILA FIRE Gc ,'3vv (if) L _1 l Cfs 03 is ii LL; RELEASE/REVISIONS 0 Lu DESCRIPTION SHOP DRAWINGS L1 0 co el K 0 te• t' co - co 0 t/) Z 0 W Q Jo Iz z O I � UJ LL i- 0) CALE: NOT IC; SCALE - DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07/11118 BACKROUND PLAN PROVIDEu BY: Proprietary and Confidential, Cop ri•ht 2013 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER: :)425.)--1 SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ DEDICATED E1dERGENCY TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE FOR ADDIDCNAL SPECIFICATIONS SEE PRCOUCT DOCLUENTATION. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC ISIX.A(TE FR DNSRIGRDIkiDINfi TO NEXT ADDRESSABLE (+ DEVICE STIP IF LAST DEVICE FRf1N XLS CONTROL. PANEL OR PREVIOUS ADDRESSABLE DEVICE r lm GR J D .I lr J HTRI-R 0 n7 0 O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE ORD N L 0 PAD -3 00 INPUT INPUT TROUBLE NACI NAC2 NAC3 NAC4 AUX + — 1 2+ 2— 2 NC C NO + — + — + — + — + — 0 (+) NAC 3 CIRCUIT NAC 2 CIRCUIT CEILIN TILE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (-) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE 1+ 0 (+) (+PREFROM XLS CONTROL PANEL OR -(4- PREVIOUS VIOUS ADDRESSABLE DEVICE END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH GROUND 0 0 0 Ln HTRI-R OSTATUS LED Co 0 N.O. 0 COM 0 N.0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 MUSIC HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY TO NEXT DEVICE OR J END OF LINE TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TINGTEMPERATU E: +32'F 0'C TO100'F 36C) HUMIDITY. 93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -- FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE rDATA IN( )> SI DATA IN(+)> DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION NTH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL > TO NEXT ADDRESSABLE DEVICE TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE HFP-11 TB1 CXX>Opp® O 110 NO COM NC TO FAN SHUTDOWN EOLR 470 i 0 SWITCH + - INPUT LED TSM -1 0 0 TO NEXT ADDRESSABLE DEVICE 0 -®I /1/1/ 2 O U NO ® COM HTRI-R "C 0 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTI❑N BOX \ MOUNTED ON CEILING FLEX \ JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 0 TO NEXT DEVICE ----CADDY BAR of SMOKE DETECTOR-- of ETECTOR— SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Jr) co C JASHINCTON 174.3 IST AVE. SO., SEATTLE, 0' cs co CV O CV LIJ RELEASE/REVISIONS (REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 07/11/18 I oz <<<< .1 CD CD z c O W 2) O) cliow2EZ 000wcn yv cC r J =J LL F— op co 0) :fat AND MOUTNING D �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07/1 1 /1 8 BACKROUND PLAN PROVIDED BY: ._JOB NUMBER: 3425-1_} SHEET FA -02 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved A B C D E F G H J K FIRE ALARM BOOSTER Project: T -MOBILE SUITE 440 Panel: EXISTING PAD -3 REMOTE Date: July 11, 2018 Module/Device POWER WSCM BOOSTER Qty SUPPLY T.I. POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 2:1 -1 -MC -CW @30cd 131 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 3735 <<<<< Total(A)= 15 Total(B)= 3875 CALCULATION Total current ratings of all devices in system (line A + line 6 + line C) 15 3875 Total current ratings con'erted to amperes (line D x .001) 0.015 3.875 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 ZR -MC -CW @licd 69 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 1 0.3227875 Add lines G and I Total Standby and Alarm AH 0.6827875 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.819345 5 TOTAL mA= 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: T -MOBILE SUITE 440 WSCM T.I. Panel: EXISTING PAD -3 REMOTE POWER SUPPLY Wire Resistance 2.58 Date: July 11, 2018 CURRENT TOTAL= 3735.00 _ (. � 1 ►�! r° 1 . t r, s fi y 'i ;d o C� fjgv-:g fir• i 76, r' i. fi4 ::: iii + • io r` r� { 2 lzH-MC-CW @15cd 87 174 DATE 07/11/18 2:1 -1 -MC -CW @30cd 131 0 2 <<<<< '21 -1 -MC -CW @75cd 222 0 1 ZH-MC-CW @95cd 292 292 1 ZR -MC -CW @licd 69 69 1 ZRR-MC-CW @75cd 200 200 DEVICES 5 TOTAL mA= 735 14 281 22.93 735 Total Wire Resistance (R) (WL * 2 ) * (Rift) 1.45 Total'Device Load, Amps (1) (Total Cct Load) 0.74 Voltage Drop (E) (E= I R) 1.07 ff, - .. 4 iilP �lbr �' Voltage- - - 24 - E)fy 22.94 jEOL je ,+{ y7 is IA4 S Y3$i L i f. 3 • 1 ,' .3 ...... yy.. �$'j _ �1i . y { ' }L}9 -- 1- ` t,'. ^ '�ua�i.. :?,Y i'ir},:. �''+y S••• i!'�' 3��i f(.=� E-' '} @ Y }_ ,. i : ai � k •:f;- < «�EiY , - - DEVICES MAXIMUM LOAD TOTAL mA= 1500 24.00 1500 Total Wire Resistance (R) (WL * 2 ) * (Rift) 0.00 Total Device Load, Amps (1) (Total Cct Load) 1.50 Voltage Drop p(E ) {E=1*R) 0.00 EOLVoltage 24 - E) 24.00 * _ ^ ^4 . , 5`i • --?ii zi8 ._ <E,bl�..x II1..'uY •mY.4:} i 1! i , s.., Y. DEVICES MAXIMUM LOAD TOTAL mA= 1500 24.00 1500 Total Wire Resistance (R) (WL * 2 ) * (Rift) 0.00 Total Device Load, Amps (1) (Total Cct Load) 1.50 Voltage Drop (E) (E= 1* R) 0.00 EOL Voltage 24 - E) 24.00 CALCULATIONS BILES FACP' Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000. FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps EXISTING TENANT JUNCTION BOX S3-1 S3-2 S3-3 S3-4 S3-5 15Cd 95Cd 15Cd 15Cd 75Cd SINGLE LINE DIAGRAM EOL S3 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. WASHINGTON Lit RELEASE/REVISIONS REV. BY: I DMG DESCRIPTION SHOP DRAWINGS DATE 07/11/18 2 <<<<< c z �- co P0) o�z Lu -w °° cc �.1 crW 0 0� LL F_ co 0) c 0 0 z LLJ 0 z Z5 0 0 CALE: NOT TO SCALL -Th DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:07/1 1 /18 BACKROUND PLAN PROVIDED BY: ,,JOB NUMBER: 34253-1} I SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved CORRIDOR D TO EXISTING TENANT ( 0 JUNCTION BOX 3 CONFERENCE S ADJACENT TENANT ROOM BACK OF HOUSE S3-2 95Cd EXi. r, TOILE OOM S3-1 �5Cd INVEN ORY S3-5 EOL 75Cd S3 SALES AREA FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. CORRIDOR FIRE ALARM SYSTEM PLAN MALL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved eft HASH I NG I ON RELEASE/REVISIONS REV. BY: 0 0 1 DESCRIPTION SHOP DRAWINGS J DATE cO 0 0 - 'Tr co Z co p H Y— F- 5rn <J m W 2z O,W(/) c2cc W'S J I_I_I j§ On LL f— CT) �CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07 1 1 1 8 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 34253-1) 1 SHEET F/' 04 O Without Comments O As Noted in Red -pc Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standands. Acceptance is subject to errors and omission ich do not authorize Ipolations of adopted standards al ici ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions of revisions to these drawings after thls date will void tris acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date:(o-D-3--1 By: 1.k.ONILA FIRS DEPARTMENT ',2.ast call 206-575-4407 and ;;We this Fire Permit No. kC-- exact address for shut - ,:.awn or restoration approval, CONFERENCE ROOM ADJACENTTEN j 716 49 Cr 8'-0" RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C—CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING EQ. STEEL. JIXST/TRUSS HANGER DETAIL NTS F P101 .. V tr_iairpgsa..._.-.:,....:L.., =2 L1W Pi.... a BACK OF HOUSE 4.04111fAt COR.RIDOR. EXISTING TOILET ROOM. CORRIDOR GYP 111 F P101_H 11 '-0" , 10'-0" GYP..-. P101 F P10t • 1/4" = 1'-0" PLAN. Design per NFPA 13 — Ordinary Hazard Group 2— 130 SF MAX All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions • 4— Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x % • 4 — Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 • E — Existing no change g- TOTAL MALL PUBLIC RESTROOMS ARE LOCATED 100 FEET AWAY. REQUIRED DISTANCE PER IPC = WITHIN 300 FEET • Pianist om ..“Dr.t12,2M • !sink, • Ws urn t. • sfsismss •,, • ITI! • tni. 1411 • Cloud Crififsity •••• • • : • FlexHead Sprinkler Drop . .• • • • • • , . . .,..1,115,405i4Oorrugated tainless steel hose with stainless steel braid • available in 2'. 3',4',5' & 6' legnths . • . -1364. ... ;s; • Multi -Port Bracket • • - • • .• • • • • .• Adjustable Hub • " • : FLEXHFAD INDUS =1711Tear • • C Flexhead omniercial Ceiling Unit T-1.3 ar Ceiling installation Model #2024,2036,2048,2060,2672 IT • -WNW • .1. •essr I. • ISY Sikesi tate • af ar • Seafood try ketpl*Ce • Css• 3.•••••: sees. 503 • Witt Gaisti. • Orli, : • ...Vs • 2oV• ass/ .4;1 • Me 141 01,1•••Int • Ma rie s • 3.iisir sasket • •a• +.•••e:ifif . r • 3 . •oct • (Az Sas • [Isle us: • foal torle• • • • siss•san f tirtriss . 20 • 2102.2.2. • usise. • ass,s, : • Iasi.* _ . • Odno /Opts • • stpaths • LS UbN12) C ••••• • WO. SI WS‘hPVC:21 • 2 - • 411,:y • sagr•••0 cosecs./ • Ks Cl•Stlisn‘ flars •...O." C2iturs • <Cary I • JCPt ntrey • JCI'enney • • thr Ceti • Stilt WO f• reef), ',site • S's • 0.100.1 ,..sSI,S2 • •14C • c c2•4•1-422.1 Csortsm lois 4. eaCk1 • bars • .•oiku • ffsrsf• • f Ci C, 13 ,.• • fee,i ill, 1 Missies _ • Si, C s - ; Pckewie KEY PLAN LE'/EL 1 OF 3 wf. • ‹tcf••••• • ef 1 ire IP es•fsiwr MMMMM •Fg•Anemiumu, cerrrortanT Noy FIRS PROTECTION SPRINKLER SYSTISNIS arearicasatning 1 V John J. Abel 9780 -069I -CG Level 3 Cie* File Plated/on, Inc. 0 F'13044 SIgnatura re 111111111151111101510111:11610t111217811a1211111101612317011111S110110 MMMMM • CROWN FIRE PROTECTION. INCORPORA TED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 Pti. (425) 481-7669 0' n T -MOBILE 984 SOUTHCENTER MALL • SPACE 440 AID TUKWILA, WA 98188 - -TUKINI-LA7 2:118RE 7-29(76) 1 ' • iLA DATE: 61 ti 1 y 1 DRAWN: 05- SCALE: 6-4 SC31, SFIGS FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON 'EC Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans ha»e been reviewed by The Tukwila Fre -,, evention Bureau for conformance with current City ;-;cndards. Acceptance is subject to errors and missions which do not authorize violations of adopted �andards and ordinances. The responsibility for the -adequacy of design rests totally with the designer. additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire cPrevention Bureau. Date: /0 -7- l By: NOTICE A completed, signed, Tirkwii� Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarrn and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. address for shut - approval. and down or SHEET NUM3ER SHEET TITLE FA -01 SYSTEv1 INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEIv CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX WISE SCHEDULE A\3 CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCJIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 1 1 1 1 3 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP ® AIR DUCT HOUSING D W/ SMOKE DETECTOR FDBZ492-HR W/ SIEMENS DUCT HOUSING HFP-11 DETECTOR HVAC DUCT WORKS HT -M SINGLE INPUT INTERFACE MODULE HTRI-M SIEMENS 4S BOX VERIFY IN FIELD TSM DUCT DETECTOR TSM -1 SIEMENS 1 -GANG BOX VERIFY'" TEST SWITCH IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S BOX CEILING FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX CEILING 0 JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N /A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND macys 4 LEVELS 250,407st \`I NORDSTROM !j 3 LEVELS 171,275st mE' i1£ P.iRE RDS StWR Y COW rT5 I I ce'e ru:o Taro ruoo CRUKK_ei ReD PIOBO» idea DUSO MNG COWINY I,DR ART .EWRERS 3q SEAM SOLE SHOES #984/986 / SPACE #440 PAID SEP 2 2014 TUKWILA FIRE aD 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-651+5 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 09/24/14 2aa«< 0 OD W Z g co (13/5O) Cf) o 2 MCD = W cr W ")W‹ O U, (W- OO co 11.1 (1) >I10) TO SCALE~ Z 0 0 u. �CALE: NOT DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/24/14 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN cc PO Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved .OB NUMBER:10177-1 SHEET FA -01} THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120YAC-60HZ DEDICATED El4ERGfNCY '' NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30WC kliN TO NEXT DEVICE T LASTADDRESSABLE a FROi XLS mNTRDL PANEL(+ Cit PREVIOUS ADDRESSABLE DEVICE GRA a HTRI—R 0 O 0 O NO1E SSEEEE PRODUCT DDOCUMAL EN AT 11O S C -CABLE C -CABLE 0 0011 ORD N LL 0000 CI PAD -3 oo ill INPUT INPUT TROUBLE NCI NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - (-) (+) 2 SPARE SPARE SPARE FROM PREVIOUS ADDRESSABLE DEVICE 2 (-) HFP-11 TB1 ®® NO COM NC 2 2 TO FAN 2 SHUTDOWN EOLR 470 0 0 SWITCH + - INPUT LED TSM -1 HTRI-M RED BLK ORG ORG GRN + TO NEXT 2ADDRESSABLE DEVICE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL DUCT DETECTOR/HTRI-M MODULE/TSM-1 SWITCH WIRING DETAIL (+) HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32' F 0' C TO 100' F (38' C) HUMIDITY: -9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR > FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD % SMOKE DETECTOR BASE REAR VIEW (-) > TO NEXT 1 I . ADDRESSABLE (+) SMOKE DETECTOR WIRING DETAIL HARD LID CEILING <440kT> 0 0 SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING DEVICE SUPPORT BRIDGE 4° SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX A t.re.?tr./ aa.dSem.. JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 i 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m D DESCRIPTION SHOP DRAWINGS DATE 09/24/14 z as<<< 1 0 w 0 Z �Q co O Cn vJ co W :10Q 200 = w Iz z w w'� cc 0 O 5i5 C/) Q �O� u- 0co)- 0 co 0) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/24/ 14 BACKROUND PLAN PROVIDED BY: \OB NUMBER:10177-1} SHEET FA -02 Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved \ 4 r ¢ A.�' � ,k., :,A,ti ✓ia1 A♦Y'.fl ,".m r"Q,,":'1 �P1;W'' �fl f m.A 17� ?rj4i � �M ��� 5 h i� •rv., r �^, '�:�,"/ ne ": , Y3 : ,, ,., Y,... ^.,..,, v ...": ...:'i. , rv✓b .. ,.'r .'a ��"' 1 kY xN y , ., ry ,. , „ @ �Gd\1 ; 9S3 4 s4!,S J!P ✓ , ;wire Resistance 2.58 i CURRENT TOT -A-1:=1669.00 rl I 1 'L ph I , (1 ,. , �. 'Y • Current Load: d'. r kr# Standby: Alarm: :,!. ! ^N y t '� y';;�.;;N f I I Y '�r,,,,. 4�! GI '.9 �I h1 M d.',. `. ZH-MC-CW @30cd 131 ZH-M C -CW @75cd 222, 4441 Device Type Qty Amps Total Amps Total Amps HFP-11 Detector 1 0,0015 0:0015 0.0015 0.0015 0 669 j FDBZ492 Duct Housing 1 0.0001 0.0001 0.0500 0.0500 0.030 HTR -R Module 1 0.0010 0.0010 0.0010 0.0010 0.069 HTRI-M Module 1 0.0015 0.0015 0.0015 0.002 0.111 0.777 ZH-MC-CW @75cd 7 0,222 0.2 1.400 ZH-MC-CW @95cd 0.0041 Amps 0.0540 Amps ":.,„,':. •, , Cs, :�mi.. bu. ..i.. a>,�:'„ �rr .. a, . .,,.., �"� ,w ".� .,., f � „��,.,1,, .A. �, £ ✓,ii�.i�a&�,,„,, .„{r'. .. .'r^t,.a .,�.a• ..., . � ;,',. 4 r r. .N., , . , A..w,i '1,'�..{.,, 5�,, ,,.r„,1 ., A.N r,�,„C. rf. ,Yrv„.^.ti4.«� ,,X,x{i >„r'i �,...,, �y �fl f m.A 17� ?rj4i � �M ��� =x«. ,Y .},,' � .,,9.'1 x,,,,,. .c +r,� , ,:; � i f�;.yy�y► �% a r ,�, I. ,;. �!y �,,4 x}�x'' iy� S , fl�w•��`, � I{M,a, �� J,,. � 9� r A r.,„ MI �� ,. t� �a�. $yi�w�' A� 1,y"�� ]k� � ,� �� 1r � � 1iJR'r,'����' ,rir ir;,;;�I N qxt i1 ;wire Resistance 2.58 i CURRENT TOT -A-1:=1669.00 rl I 1 'L ph I , (1 ,. , a 'Y • ',.. ,, 7 1'w„9:.; F ', , �� • ,..” , ' 4 E ,� Curie d'. r kr# 9 ', i'. 1 r f;;! �5,,, r'9'@” P:kl,k' ! r r r,u :,!. ! ^N y t '� y';;�.;;N f I I Y '�r,,,,. 4�! GI '.9 �I h1 M d.',. `. ZH-MC-CW @30cd 131 ZH-M C -CW @75cd 222, 4441 Device Type Qty Amps Total Amps Total DEVICES ZR-IVIC-CW @30cd 111 ,5 TOTAL -in' iA= ` 0 669 j 14 159 Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW @1 c 16 0.087 0.069 1.104 Z1 -1 -MC -CW @30cd 7 0.131 - 0.67 0.55 23.45 0.111 0.777 ZH-MC-CW @75cd 7 0,222 0.2 1.400 ZH-MC-CW @95cd 0.292 0.264 ZR -MC -CW @'IScd 15 ; :: 0:069 0.069 1.035 ZR -MC -CW @30cd 1 0.111 0.111 0.111 0.111 0.141 Amps 4.457 Amps Standby Current Load: :' 0.141 Amps For 24 Hours = 3.384 Amp -hours Alarm Cur en Load: ' 4.457 Amps For 5 Minutes= 0.374 Amp -hours 25% Derating= 4.698 Amp -hours Total System Current Load: 4.698 Amp -hours �G Y .� „ Ni�'� wRECOMMENDED D��I�11��1 ' 1� w � x } � }, ° rim ^'', ,�1,� ;�"r' ,,. ;�►�� `" wxr�� r%'�"r4 d 1.'',"AI t, 1 ,�,'',s 1s r;✓ .4''{.'>:',,'+r, , � t TO NEAREST EXISTING DATA LOOP (BACK -OF -THE -HOUSE) TO EXISTING POWER SUPPLY (BACK -OF -THE -HOUSE) SYSTEM CALCULATIONS S1-1 S1 -2 S1 -3 S1-4 S1 -5 15cd 15cd 15cd 75cd 75cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 'REV. BY: I Notification Appliance Circuit Detail SOLE SHOES PROJECT: Panel, Date: j EXISTING PAD -3 POWER SUPPLY September 24, 2014 ;wire Resistance 2.58 i CURRENT TOT -A-1:=1669.00 rl I 1 'L ph I , (1 ,. , a 'Y • Vhl: ! ; C • 1ZH-MC-CW @15cd 871 87 2 ZH-MC-CW @30cd 131 ZH-M C -CW @75cd 222, 4441 2 ZFI-MC-CW .95cd 292.. !ZR -MC -CW @l5cd 69; 138 DEVICES ZR-IVIC-CW @30cd 111 ,5 TOTAL -in' iA= ` 0 669 j 14 159 23.45 3 .. 669 Total Wire Resistance R) '( WL *2 ) * (R/ft) 0.82 Total Device Load, Amps (1) ,Voltage Drop p ( E ) (Total Cct Load (E- I R) 247-i) - 0.67 0.55 23.45 EOL Voltage SYSTEM CALCULATIONS S1-1 S1 -2 S1 -3 S1-4 S1 -5 15cd 15cd 15cd 75cd 75cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 'REV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 1 09/24/14 0 a W o � �r J W zUW�t ao --� 0 C� (ocO) Z W< :JO CJ) = W Z z Cly < W 2 w CJ) —1 cc Og ; 0 IA 0 cc cr) I- co I- 0 U co a) w (J) >- Cl) 4-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:09/24/14 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM .10B NUMBER:10177-11111} SHEETff FA-03 Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved \ } EXISTING STOCKROOM & ACCESS. TOILET ROOM TO REMAIN WITH NO CHANGES (SHOWN SHADED) EXISTING STOCKROOM TO REMAIN WITH NO CHANGES: CEILING: OPEN TO EXISTING METAL DECK ABOVE @ +16'-10 1/4" A.F.F. WALLS: EXISTING 5/8" TYPE 'X' GYP. BD. TO REMAIN FLOOR: EXPOSED CONC. TO REMAIN -•a FURR OUT WITH 1 5/8"-20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE 'X' GYP. BD. (FLR. TO CLG.) 4'- 4' - II H NO CHANGES 0 EXISTING 12'-0" HIGH STOCKROOM SHELVING w/ SEISMIC BRACING TO REMAIN WITH NO CHANGES (TYP.) TO NEAREST EXISTING DATA LOOP (BACK -OF -THE -HOUSE) TO EXISTING POWER SUPPLY (BACK -OF -THE -HOUSE) TEL b EXISTING 12'-O" HIGH STOCKROOM SHELVING W/ SEISMIC BRACING TO REMAIN (TYPICAL) S1-4 mei 75cd TSM EXISTING MGR. DESK 6" WIDE X 6" HIGH ROOM IDENTIFICATION SIGNAGE WITH BRAILLE CHARACTERS @ +60" A.F.F- SEE A-6 FOR ADDIT. INFO. EXISTING HANDICAP ACCCESSIBLE TOILET ROOM TO REMAIN WITH NO CHANGES: CEILING: EXISTING 5/8" TYPE 'X' GYP. BD. CLG. @ +8'-0" A.F.E. WALLS: EXISTING 5/8" W.R. TYPE 'X' GYP. BD. FLOOR COVERING: EXISTING 12"X12" CERAMIC TILE & 5" HIGH INTEGRAL COVE BASE T 1 T 8 STAINED WOOD MIPROR FIXTURE SEE 2/A-5 (TYP.) 48" WIDE X 8" DEEP STAINED WOOD SHELVES MOUNTED ON CONCEALED SUPPORTS SEE 3/ A-5 (TYPICAL) ACCESS'BLE NEW CASHWRAP TOP @ -34" A.F.F 1 SEE 1/ A-5 48" WIDE r. 8" DEEP STAINED WOOD SHELVES MOUNTED ON CONCEALED SUPPORTS SEE 3/ A-5 (TYPICAL) S1-5 75cd 1 T SL FREE-STANDING SHOE DISPLAY w/ INTERNALLY ILLUMINATED WHITE PLEXIGLAS BLOCK SEE 5/A-5 FREE-STANDING SHOE DISPLAY w/ INTERNALLY ILLUMINATED WHITE PLEXIGLAS BLOCK SEE 5/ A-5 60'-9" EXISTING SALES AREA: CEILING: NEW 5/8" TYPE 'X' GYP. BD. © +11'-0" A..F.F.- PAINT 'G1' WALLS: EXISTING 5/8" TYPE 'X' GYP. BD.- PATCH & PAINT (G1) FLOOR: NEW 20"X20" PORCELIN TILE 'PF -1' WITH ZERO TOLERANCE GROUT JOINTS WITH 6 1/2" HIGH 'PB -1' TILE BASE THROUGHOUT SALES AREA. GROUT TO tv1APEI NON SANDED 09 GRAY K EXISTING MALL I CERAMIC iILE FLOOR PLAN - FIRE ALARM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. EXISTING 1/2" THICK CLEAR TEMP. GLASS SET 6" HIGH S.S. GLAZING BASE & 4"x4" VERTICAL MULLIONS WITH 1/8" AIR GAPS- BUTT JOINT TO REMAIN (TYP-BOTH SIDES) v ti CC 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION I SHOP DRAWINGS DATE_ 09/24/14 2CCaaC 0. O IA co Z O03 O Q T (f)o Ci) o) W ZIp = w frz w pc WQ_I U� o 02 U- co i- 0) d' 0) W CC ilm SCALE: 1/4”=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/24/14 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 1 01 77-1, SHEET FA -04 1 Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved Without Comments As Noted in Red Per The Attached Letter DEPARTMENT Please call 206-575-4407 and Sive this Fire Permit No. 1�!-S-ata and exact address for shut- down or restaraxi approval. plans have been reviewed by The Tukwila Fire (tion Bureau for conformance with current City _yards. Acceptance is subject to errors and :;:ons which do riot . +jl:norize violations of adopted .:ards and ordinancerF, The responsibility for the ,.,uacy of design rest{ i:otally with the designer. ',.lieions, deletions s::•:• r:: ktisions to these drawings after ; s date will void t ,K.:“c eptance and will require a :suomittal of rr: vis:_:.' %t; Ewings for subsequent approval. .,Inas acceptance is sunject to Meld test and inspection by me Tukwila Fire Prevention Bureau. Date: /0 Bv: I 1 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS 3/e' ALL THREAD ROD PIPE SWIVEL RING EXISTING STOCKROOM 4 ACCESS. TOILET ROOM TO REMAIN WITH NO CHANGES (SHOWN SHADED) OTE: LI EXITWAYS ARE TO BE ILLUMINATED O AT LEAST ONE FOOT CANDLE AT THE LOOR LEVEL. EXISTING STOCKROOM: CEILING: OPEN TO EXISTING METAL DECK ABOVE • +16'-10 I/4" AFF. NEW 5/8" TYPE 'X' GYP. BD. LIGHT COVE +II' -8" AFF. TAPE, FINISH 4 PAINT 'GI' WHITE EXISTING 5/8" TYPE 'X' GYP. BD. CURTAIN WALL:BOTTOM a +10,-R" AFF.- PAINT 'GI' EXISTING r2 ALUM REVE. TO REMAIN APPROX. LOCATION OF EXISTING BLOWER TO REMAIN EXISTING CCt PACT FLUOR LIGHT FIXTURES TO BE REMOVED 4 REPLACED WITH NEW LW DOWNLIGHT (TYPICAL OF 1) EXISTING 5/8" TYPE 'X' GYP. BD. CEILING a 13'-0" AFF. PAINT (GI) • FlexHead Sprinkler Drop . Corrugated stainless steel hose will: stainless steel braid ravailable in 2', 3',4',5' & 6' legnths . . EXISTING LEASE LINE Multi -Port Bracket APPROX. LOCATION OF EXISTING BLOWER TO REMAIN EXISTING 5/8" CEILING a 13' - EXISTING .120 WITH BLUE PO TO REMAIN TYPE 'X' GYP. 1315. 0" AFF..COVERED WITH WK ALUMINUM PAi NML L ER COATED FINISH EXISTING 5/8" TYPE 'X' GYP. BD. CEILING 13'-0" AFF. PAINT (GI) .. • Adjustable Hub • • Flexheadr ommerciaCeiling Unit T -Bar Ceiling Installation • Model ##20 4,2036,2048,2060,2072 ACCESS P SEE 1/A-2 •'STRIPE' IGWTS' .• SOLE SHOES SOUTHCENTER U1ESTFIELD TENANT SPACE 0440 984/ S% SOUTHCENTER SEATTLE, WASHINGTON 98188 A a a a a a1. a L EXISTING 5/8" TYPE 'X' GYP. BD. CEILING e 13'-0" AFP. PAINT (Gl) EXI TING HANDICAP Ac;.CC'ESSIBLE TOILET ROOM TO REMAIN WITH._NO CHANGES: CEILING: EXISTING 5/8"TYPE 'X' GYP. BD. CLGx. e i '-0" AFF. 5/8" TYPE 'X' GYP. BD. CEILING a +12'-0" AFF.. FINISH 4 PAINT (GI) NEW 5/8" TYPE 'x' LIGHT COVE a +II' -8'; AFP TAPE, FINISH 4 PAINT 'GI' WI-IITE EXISTING SALES AREA; CEILING: NEW 5/8" TYPE. 'X' GYP. BD. g +Il' -0" AFF. PAINT 'GI' b-m'Si SI1aa--M-se------- WASHINGTON STATE ERTIFICATE OF COMPETENCY ECTION SPRINKLER SYSTr ohn Ales 9&7:0591 -CG Level3 r Pt4,41 Fire Protection, Inc. i ' O FP044L Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart 0 Empires 19t3i/14 ---a o 1— Add Globe Model GL5615 Quick Response 155° Brass Uprights 1/2 x 1/2 o 9 — Add Reliable Model G5-56 Quick Response 165° Concealed Pendants 1/2 x 1/2 (white) • E — Existing no change CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 SOLE SHOES SOUTHCENTER WESTFIELD TENANT SPACE *440 984/ .986 SOUTHCENTER _SEATTLE, WASHINGTON98188_ DATE: r:; ..t3. I'4 DRAWN: SCALE: PAID SEP 24 20141 c.n TUKWILAFIRE. to l SHIEK SHOES FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL), RISER FA -04 FIRE ALARM SYSTEM FLOOR PLAN WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD *14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD *16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD *14 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD *16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR *14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDIO TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED *18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO *16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL 1W CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-112" .82 SQUARE INCH 2 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT 3 2 2 1 EX FATP FIRE ALARM CONTROL PANEL MXL SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP TRI -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD TRI -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP BOX VERIFY IN FIELD DUCT SMOKE DETECTOR AD2-2P SIEMENS HFP-11 DET DUCT HOUSING VERIFY IN FIELD SMOKE DETECTOR (PHOTOELECTRIC) HFP-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM E 5 STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM PAM MULTI -VOLTAGE RELAY MODULE PAM -1 AIR PRODUCTS 4S BOX VERIFY IN FIELD FIRE SMOKE DAMPER F.B.❑, N/A VERIFY IN FIELD FATC EX JUNCTION BOX F.B.O. F.B.O, N/A VERIFY IN FIELD C> WATERFLOW SWITCH F.B.0.__ F.B.O. N/A VERIFY IN FIELD O TAMPER SWITCH F.B.O. F.B.O. VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 0 01 0M co coo coo co co _! 0) W adz (i) oC CD U),rz: tu) ctft) w ¢ I� () LL ‘ALE: 1'=1 /8" DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/09/1 0 BACKROUND PLAN PROVIDED BY: J0B NUMBER: 14 SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCT OVER 3' WIDE; SAMPLE TUBE MUST GO 11 -IRU THE DUCT AND BE CAPPED. BEND OR OTHER OBSTRUCTION BEND OR OTHER OBSTRUCTION DUCT DETECTORJ LOCATION TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE 120VAC-60HZ DEDICATED EMERGENCY NOTE: FOR AI:CM:NAL SPECIFICADONS SEE PRODUCT DOCUNDITATION. SUPERVISORY PONT FORM 'C. RELAY CONTACTS LED 'CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL-(+ OR PREVIOUS ADDRESSABLE' DEVICE 11) 0 GRIN :5) MODEL: HTRI-R Rti N 00 OD 00 0 PAD -3 0 INPUT INPUT TROUBLE NAL:INAC2 NAC3 N4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 3.15k EOL IT! TYPICAL WIRING FOR HTRI-R MODULE (PAD -3 TRIP) SCALE: NONE rl 1,7,:j1,MIM TO THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE W111-1 NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. BATTERY TUBE OUTLET SAMPLING TUBE INLET— SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD -2P DUCT DETECTOR SCALE=NONE SPEAKERISTROBE r ...1 11 II jEnmL I' • .....011Mins... . - I 111 1111 — — ::':.::' .°.. 1 1 1 I i h 1 I I i li n1S. F7-1. rf' am IN C Agall 7j. } 0 1110 . 0 - • r -131 11 . 11; IDEp s 1 i.f.t) •::' \\s\j 7..h ! 2 —1 L21.!'"'?ii.:1!67.1*/ i / 4.'1 • _ I —.....--- FROM PRECEDING STROBE APPLIANCE OR SYNC MODULE (—) NAC -4 NAC -3 , NAC -2 (+) NAC -1 FROM PRECEDING SPEAKER< (+) OR FIRE ALARM SPEAKER CIRCUIT CONTROL PANEL (FACP) SPEAKERISTROBE AND STROBE WIRING () (+) STROBE CIRCUIT SPEAKER n -DI ii 11 1.-1, • o I - _____-----------....„. 0 I rf:1 ,1 I I- , SHOP DRAWINGS 1 1 I i 1 0 zz., 0, 0 --.. p.) i ' I h [:::°j (T. F f ?1,. - o o o o +SIAM - am IN C Agall 1fL'_.' Tf - -. - .1' 0 1110 . 0 - • r -131 11 . 11; IDEp (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERATURE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS LISTED FOR MR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE ---> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE [DATA IN (—) > DATA IN (+) > REAR VIEW (-) > TO NEXT >--4 ADDRESSABLE HFP-11 SMOKE AND DB -11 DETECTOR BASE-VVIRING DETAIL LABEL SCALE STROBE SPEAKERISTROBE 1 I I ?1, TROBEn TROB IRCUI (+) ' DEVICE > STROBE CIRCUIT FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0rri (+) WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR FYITH SHIELD #18 FPUFPLR RED (JACKET) 'CONTACT RATINGS 4.0A 0 t25VAC 4.0A 0 30= FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 GENERAL NOTES (—) TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE 1. SPEAKERS ARE TAPPED AT 70.71/4 WATT. 2. STROBES CANDELAS ARE ON THE FIELD DRAWINGS. 3. CHECK CUT SHEETS SUPPLIED WITH PARTS BEFORE HOOKING -UP. 4. ALL ALD LOOP WIRES MUST BE IN METAL RACEWAY. 5. ANY ALD LOOP WIRE THAT GOES TO FANS 1 DAMPERS THAT ARE PART OF PRESSURIZING OR VENTING SMOKE CONTROL, NEED TO BE IN METAL RACEWAY AND 2 -HOUR PROTECTED ( CI CABLE OR ENCLOSED IN 2 -HOUR CONCRETE OR SHEETROCK. SCALE:1/2'4 ) (4_-) (-) (-) SPEAKER CIRCUIT (+) (+) I (+) „ NOTE FOR ADDITIONAL SPECIF1C&11ONS SEE PRODUCT DOCUMENTATION. (+) TO NEXT APPLIANCE OR 24K (EOLR) (+) TO NEXT SPEAKER ----5 OR END OR LINE RESISTOR 24K (EOLR) (—) SPEAKER CIRCUIT 10 JUNCTION BOX— MOUNTED ON CEILING FLEX / • JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 1 GROUND L 1ODEI TRI -R 0 --)4+)TO NEXT DEVICE OR >(—) STOP IF LAST DEVICE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID —, CEILING DRY CONTACTS TO VAV FAN SHUTDOWN — PROVIDED BY MECHIEIEC. SPEAKER SUPPORT TILE BRIDGE —4" SQUARE DEEP BOX —, / WITH 1-1/2' EXTENSION "\ CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE OTO NEXT DEVICE / 00 CADDY BAR SMOKE DETECTOR JUNCTION BOX MOUNTED ON CEILING FLEX `— SUSPENDED ILLUMINATED CEILING JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 6 00 00 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR -- SMOKE DETECTOR MOUNTING SUSPENDED ILLUMINATED CEILING FA -82 SCALE:NONE STUD SHEET ROCK SPEAKER STROBE OR STROBE ONLY \ \ \ I ‘ i 4S DEEP BOX W/ 1-1/2' EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) F) c0 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z _ DESCRIPTION SHOP DRAWINGS DATE 0 zz., 0, 0 --.. p.) 12 «C« r co 0) co co C) c70 n (Is z ‘CALE: NT DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE:3/09/10 BACKROUND PLAN PROVIDED BY: 11 WALL MOUNTED SPEAKER STROBE FIRE MOUNTING ELEVATIONS .913 NUMBER: SCALE=NONE Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA 02) SYSTEM CALCULATIONS ;Wire Resistance 2.58 0 SET -MC @15CD 0 SET -MC @30CD 2 'SET -MC @75CD 1 Z-MC@15CD 0 ; Z-MC@30CD DEVICES= 3 98 175 64 98 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage 0 350 64 0 414 14 197 19.98 (WL*2)*(R/ft) (Total Cct Load (E=I*R) ;20.4-E) 414 1.02' 0.41; 0.42 19.98! PROJECT: Y SHIEK SHOES Panel: XLS-V (Wire Resistance 2.58 0 2 0 0 DEVICES= 70.7V 1/8 1.8 0 70.7V 1/4 3.6 7.2 70.7V 1/2 7.2 0 70.7V 1 14.4 0 2 TOTAL mA= 7.2 14 240 20.39108352 7.21 Total Wire Resistance (R ) ( WL * 2 ) * (Rift) Total Device Load, Amps (I) (Total Cct Load) Voltage Drop (E ) (E= I * R) EOL Voltage (20.4 - E) 1.24; 0.01 0.014 20.39 : AD1 Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0 0.0022 0.0022 0.0023 0.000 AD2-P 2 0.0635 0.0635 0.064 0.128 HTR -R 0.009600 0.0096 0.021 0.063 HTRI-D 0 0.001600 0 0.0035 0.000 0.0731 Amps 0.191 Amps Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours Alarm Current Load: 0.191 Amps For 15 Minutes 0.048 Amp -hours 25% Derating= 2.253 Amp -hours Total System Current Load: 2.253 Amp -hours Battery Pair to be Used 12VDC Amp -hours 7AH trv'f68 n e t ry L ac C Ilcul bra EXttltt"IS DESCRIPTION SHOP DRAWINGS un Load. c k Y Sl r dby: ` larm: 0 0) 0 M Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC @15CD 0.064 SET -MC @30CD 0.098 SET -MC @75CD 2 0.175 0.350 ZR -MC @15CD 1 0.064 0.064 ZR -MC @30CD 0.098 0.03 Amps 0.444 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.444 Amps For 5 Minutes= 0.037 Amp -hours 25% Derating= 0.947 Amp -hours Total System Current Load: 0.947 Amp -hours ry, .air to be Us d r :' . 1` Vf 2 { .. %{■ i�€i ti -ho 7AH VOLTAGE DROP CALCULATION ATTERY SIZING CALCULATION 1101101 .1010.1.4.00441.6140. MIANS,fnIMMPiMIMMlf.IMWMMMVMMV.Wrvtorr.t. DEDICATED EMERGENCY POWER 120VAC-60HZ cO 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NVI DESCRIPTION SHOP DRAWINGS DATE 0 0) 0 M co oo wco Wz W 0 O �Q0 _ CI)ccz cc w(1) W < w wvg 0 Cr) CU cc cf)w LL w z w z 0 SCALE: NTS DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/09/ 10 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved \0B NUMBER: ,1 % SHEET FA -03 EOL—S1 SCK LFOvE s . b'-': 14V5,4 . �� F�'T i: TE T L ET, ;X22.'..:,"1 =E 1 _v 1 1-16' —12 Lam_ [ a J.544.F TO = — = EE t 'J'40_r▪ 3,.63 Gt: a:J.:N • =D,3=E Tx=C41_ 2S,2V -- 2S,2V S1-3 V1-3 EOL—V •'1.1ti'L R3 CE3C. '-' 64 -ELVES T7 -Jv4 ==L c:., t " 15TGLL=,. 1-1 1.2'.2TC- EL7 AFF • S'_C-GFS-. v` s_C µW SJ F1•' : yI• cF-.: `rLGE3 � NORTH 3:4' 1_4:, T=rR. G-_433 G:3=Lr`" v?J3 SEE G..- .: FG4; . LL cX 5,3?_E 2'X L+ -▪ H • 'LL 4..,,G.3 SET b - 5E.1 -O&& L.:CE` EY. 3T LE34E .:;v..=�; AL.. - Dc3 =�i'lir;.E 1 a'Y tt. ILL Li SHIEK SHOES -F'=' '"-L 453 c=T •.ERT' 1.8- 4'R G4i'5- SCALE 1/8"=1' FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE THESE DEVICES. 4> FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. TENANT FIRE ALARM JUNCTION BOX (FIELD LOCATE) EXISTING CORE AND SHELL FIRE SMOKE DAMPERS RELAY TRIPS TO ACIVATE AND MONITORS PAD 3 TIE TO EXISTING DEVICE TIE TO CLOSES EXISTING SPEAKER STROBE 10 RELOCATE EXISTING DEVICE TIE TO EXISTING EOL REPLACE WITH_15CD SPEAKER STROBE FIELD LOCATE HVAC UNITS SMOKE MUST BE LOCATTED IN THE SAME ROOM AS THE POWER SUPPLY. REFFER TO RISER ON PAGE FA -03 FOR VOICE/SPEAKER WIRING ELECTRICAUINSTALLING CONTRACTOR SHALL RETURN ONE FULL SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved m 7' ti 2 ct D 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS 0 w < o (7)'n 0 M Z 0 CC 0 0 wco e W ;is, LL W Vi W 2coz w JO O � _ 2z �W= W w v� >•- win cf) EE:F E (f)O w cc �CALE: NTS DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/09/10 BACKROUND PLAN PROVIDED BY: `JOB NUMBER: SHEET FA -04 � FULL' G6' SHEET INDEX SHEET NUMBER SHEET TITLE SHIEK SHOES FIRE ALARM SYSTEM TUKWILA, WASHINGTON FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL), RISER FA -04 FIRE ALARM SYSTEM FLOOR PLAN E. 'FE Ir Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire nr,; ention Bureau for conformance with current City ;r;, ndards. Acceptance Is subject to errors and ornisions which do not authorize violations of adopted ;.. r aids and ordinances. The responsibility for the .:C& Uacy of design rests totally with the designer. ;n;i;cions, deletions or revisions to these drawings, after ti -Fs t!?te will void this acceptance and will require a resubrnittai of revised drawings for subsequent approval. ai acceptance is subject to field test and inspection by ne Tukwila Fire Prevention Bureau. _are: ` -1° By: 1...1 I UKWII"A FIRE DEPARTtiltstit Please call: 575.4402 artd give this job No. 10 F-Osti and exact address for shut' Town or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Reinspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1�2" .82 SQUARE INCH 2 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS,- HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND -ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. . 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED SYMBOLS LEGEND QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT 1 3 1 1 2 1 EX FATP FIRE ALARM CONTROL PANEL MXL SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD TRI -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP BOX VERIFY IN FIELD DUCT SMOKE DETECTOR AD2-2P SIEMENS HFP-11 DET DUCT HOUSING VERIFY IN FIELD SMOKE DETECTOR (PHOTOELECTRIC) HFP-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1 G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXT. I FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1 /2" EXT. 80" A.F.F. TO BOTTOM 15 STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM PAM MULTI -VOLTAGE RELAY MODULE PAM -1 AIR PRODUCTS 4S BOX VERIFY IN FIELD FIRE SMOKE DAMPER F.B.O. F.B.❑. N/A VERIFY IN FIELD FATC EX JUNCTI❑N BOX F.B.D. F.B.O. N/A VERIFY IN FIELD Fs WATER FLOW SWITCH F.B.❑. F.B.D. N/A VERIFY IN FIELD O TAMPER SWITCH F.B.D. F.B.O. VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.D. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A MAR 24 2010 Tukwila Fire Copyright 2006 by Guardian Security Systems, Inc. All Ri • hts Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 3/09/10 coo W (r)� z W w Jo co 2z cf) W cc = � Q W Q w� _ ccco -T- EsE = S 0 �CALE: 1 '=1 /8" DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZAN1 DATE: 3/09/10 BACKROUND PLAN PROVIDED BY: JOB NUMBER: SHEET 1 FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCT OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. BEND OR OTHER OBSTRUCTION BEND OR OTHER OBSTRUCTION DUCT DETECTOR- LOCATION TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE 120VAC-60NZ DEDICATED EMERGENCY NNE: FOR ADMIONA. SPE(&1CATIONS SEE PRODUCT DOCUMENTATION. M(YN I E OPTIONS ® SUPERVISORY POINT ® FORM -C- RELAY CONTACTS LED *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC fs7. FkfD,SGi611 rfT TO NEXT ADDRESSABLE -� DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL-(+ OR PREVIOUS ADDRESSABLE - DEVICE JAI CRD N t. =1 no on oo TO THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET—\ SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND 2 TYPICAL MOUNTING FOR AD -2P DUCT DETECTOR BATTERY PAD -3 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX - + - + - + - 1+ 1- 1 2+ 2- 2 NC C NO + - + NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL WIRING FOR HTRI-R MODULE (PAD -3 TRIP) SCALE: NONE FA -02 SCALE:NONE SPEAKE STROBE 'am❑I 11 11 1❑.1b, o/.,.K.1 r .. "-^\ ■ 1 0 1 n 1 \`, t Q- is it I; ;./ A 1 ( li rs` n. 1 0 `1 o a 0 0 ti - .h - 1 ,��\� ,y' .- AeCDEr ON - 4. a ._.I \ mN • _.: ea - 4 ..s ._ 1 �* / j\\ _ FROM PRECEDING STROBE APPLIANCE OR SYNC MODULE (-) NAC -4 e NAC -3 NAC -2 (-) STROBE CIRCUIT SPEAKER CIS ■I 11 Il IULJU 1 - 1 - 1 o1 a. 1 I 1 o ' \`, - / 1 Q- is it I; ;./ A .^ ;mom ( Aecetrot =' > .4113 i. o a 0 0 . AeCetroN .h - ,_ - + oto m -. ,y' ■► i......ijammi❑omp NAC -1 FROM PRECEDING SPEAKER 4( (+) OR FIRE ALARM SPEAKER CONTROL PANEL (FACP) CIRCUIT SPEAKERISTROBE AND STROBE WIRING SCALE:112`=1' 1 1 iI� 1 (+) I (-) (-) (-) TROB IRCUI NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN TEMPERATURE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -- DEVICE 1S USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR •— DB -11 STANDARD SMOKE DETECTOR BASE —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > REAR VIEW (-) HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL > TO NEXT (-) ADDRESSABLE (+) > DEVICE (+) LABEL SCALE STROBE Il❑ 1 1 1 SPEAKERISTROBE ❑ 01 i ❑ 0/- El 1 il:1,2 z Q 1 - DESCRIPTION II, ;I il ;! .^ ;mom ( M .- AeCetroN _ 4. a ._.I \ mN • 1 (-) TROB 1 1 0 7 1 1 0 [ [ \- TA IRCUIIar` 0 SPEAKER CIRCUIT (+) C (-) (+) FOR ADDITIONN. SPECIFICATIONS SEE PRODUCT DOCUMENTATION. I.I! LL? (+) • • (-) (-) JI a n STROBE CIRCUIT (-) FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. m 0 0 0) (+) TSM -1 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPLJFPLR RED (JACKET) 'CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 GENERAL NOTES (-) TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE 1. SPEAKERS ARE TAPPED AT 70.7114 WATT. 2. STROBES CANDELAS ARE ON THE FIELD DRAWINGS. 3, CHECK CUT SHEETS SUPPLIED WITH PARTS BEFORE HOOKING -UP. 4. ALL ALD LOOP WIRES MUST BE IN METAL RACEWAY. S. ANY ALD LOOP WIRE THAT GOES TO FANS 1 DAMPERS THAT ARE PART OF PRESSURIZING OR VENTING SMOKE CONTROL NEED TO BE IN METAL RACEWAY AND 2 -HOUR PROTECTED (CI CABLE OR ENCLOSED IN 2 -HOUR CONCRETE OR SHEETROCK. S TO NEXT APPLIANCE S OR 24K (EOLR) (+)_4 TO NEXT SPEAKER OR END OR LINE RESISTOR (-)24K (EOLR) SPEAKER CIRCUIT JUNCTI❑N BOX---‘ MOUNTED ON CEILING FLEX ry/ ',,/ //z <;/// JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT GROUND . u � � c 0 MODEL: TRI -R 0 0t ; DRY CONTACTS TO VAV FAN SHUTDOWN — PROVIDEDBYMECHIELEC. I -C44 0 —.(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2' EXTENSION \\ CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE:NONE ) per" OTO NEXT DEVICE 0 0 CADDY BAR SMOKE DETECTOR JUNCTION BOX-\ MOUNTED ON CEILING FLEX i -- SUSPENDED ILLUMINATED CEILING 7-'77A), JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 0 0 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING STUD SHEET ROCK SPEAKER STROBE OR — STROBE ONLY 4S DEEP BOX W/ 1-1/2' EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) O CD z (I) LU J uJ (n LC) to (/) (V \O Q I– O — (V re) J w FAX (206) 628-4990 RELEASE/REVISIONS REV. BY: z Q DESCRIPTION SHOP DRAWINGS DATE 0 el 0 M 2 C<QCC z z 0 co W co cf) W 2 (0 2 w Jp O < co2z CO w = � gzQ W Q wUJ 0 's T CC u 1� OD M (U CALE: NTS DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZAN I DATE: 3/09/10 BACKROUND PLAN PROVIDED BY: 11 WALL MOUNTED SPEAKER STROBE FIRE MOUNTING ELEVATIONS UN NUMBER: SCALE:NONE SHEET Copyright 2006 Guardian Security Systems, Inc. All Rights Reserved FA -02 by 9 SYSTEM CALCULATIONS PRO :S ilk ► Panel: XLS-V ;Wire Resistance 2.58 0 SET -MC @15CD 0 SET -MC @30CD 2 SET -MC @75CD 1 Z-MC@15CD 0 Z-MC@30CD DEVICES= 3 64 98 175 64 98 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 0 0 350 64 0 414 14 197 19.98 WL * 2 )* (R/ft) (Total Cct Load) (E=I*R) 20.4 - E) 1 4141 1.02 0.41 0.42 19.98; PROJECT: S IIEK SHO Panel: XLS-V 'Wire Resistance 2.58 p 0 .� � _.. 70.7V 1/8 1.8 0 . _4 .. ___ �_ ._ .._. _ _.,_ _ ,. _W_ s2 SHOP DRAWINGS 2 70.7V 1/4 3.6 7.2 DATE 0 a) 0 0 70.7V 1/2 7.2 0 Total Amps Total 2C<<QQ 0 70.7V 1 14.4. 0 . Main System Board 1 0.03 DEVICES= 2 TOTAL mA= 7.2 14 240 20.39108352 7.21 SET -MC @30CD Q.098 SET -MC ©75CD 2 Total Wire Resistance (R) 0.175 0.350 (WL * 2 )* (R/ft) 1.24; Total Device Load, Amps (I) 0.064 0.064 (Total Cct Load) 0.01 Voltage Drop ( E) (E= I* R) 0.011 0.444 EOL Voltage (20.4 - E) :20.39, Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours P.,ADD ONS, Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total NFP -11 0.0022 0.0022 0.0023 0.002 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 3 0.009600 0.0096 0.021 0.063 HTRI-D 0 0.001600 0 0.0035 0.000 0.0731 Amps 0.127 Amps Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours Alarm Current Load: 0.127 Amps For 15 Minutes 0.032 Amp -hours 25% Derating= 2.233 Amp -hours Total System Current Load: 2.233 Amp -hours Battery Pair to be Used 12VDC Amp -hours 7AH r:i K Kry .� nJ } b � Y i 'K s`J I � ; .�° tyY � 3) q ( " ',.f V ,{,.`"• ePy„{�'d e� T£�M"sry" 1 •Y �, .■(�y'y^.. rL k ' J � Ma: a � ; na Exten er P ne xa e the tions I I DESCRIPTION SHOP DRAWINGS r, Y :r fir'. .. k C renti oa'.d• 3,,, + iYb x''; K+ '" ta' db .'. wII h' k,� A.,. -Alarrrl�. DATE 0 a) 0 Device Type Qty Amps Total Amps Total 2C<<QQ Main System Board 1 0.03 0.03 0.030 0.030 SET -MC ©15C 0.064 SET -MC @30CD Q.098 SET -MC ©75CD 2 0.175 0.350 ZR -MC @15CD 1 0.064 0.064 ZR -MC ©30CD 0.098 0.03 Amps 0.444 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.444 Amps For 5 Minutes= 0.037 Amp -hours 25% Derating= 0.947 Amp -hours Total System Current Load: 0.947 Amp -hours Eat ry' Pair tc► be Used ` p ou VOLTAGE DROP CALCULATION BATTERY SIZING CALCULATION EOL -S S1-3 S1-2 S1-1 V1-2 V V1-1 FIRST FLOOR V - BPS 2C FATC 'EOL -V1 DEDICATED EMERGENCY POWER 120VAC-601Z RISER DIAGRAM 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a I DESCRIPTION SHOP DRAWINGS DATE 0 a) 0 M 2C<<QQ n ‘CALE: NTS DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/09/1 0 BACKROUND PLAN PROVIDED BY: .JOB NUMBER: Co • ri • ht 2006 b Guardian Securit S stems, Inc All Ri • hts Reserved SHEET FA -03 _<t -SCK A_ _ • _;4;: _ 5,577.. `.FJ 5•E` -77-67. X. eG -P4.? t:•• -;•TE. .CT =Ynp5.7.G C --r- •0 rz="Lz: 1-15 1-14 1_=. V L- 70,F 4 3^7•7C+'? E OEE Tr F,C..4.L S1-3 EOL—S1 V1-3 i.j ////Y� I /t EOL—V _1— 45` L1. r ; Z` fL'02 3:3' LA: TE4'P.G-LG.3—' G,S=LAY EEE _ .- I !rF 4; ;,:4i= 5:5" 'l?=E 'X' all. 30 04.3. Ix -0- APS.- =AN -7 'G' ° . NORTH CG5k�R4� _E_ 4,4-1/ 4== :E'.✓'LN G.:S-=0: SHIEK SHOES <=x'' - NER J i'Pi F_=L_ I•.` iF.:�G C tLF GLASS41. c_T 6- 3 .0T :.Ihi BASE 4 1.3= 4 x?. E=:T -,.. ECF -4 _3. .=Y.�•�Y- Lea= AL -0. F,tNELl'3-.;:_44 ALL 4 617:7517)E G_X J1 . L.4 004 TO __s I.3 ..'R 0.P3- a.: SCALE 118":t FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE THESE DEVICES. 4> FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. TENANT FIRE ALARM JUNCTION BOX (FIELD LOCATE) EXISTING CORE AND SHELL FIRE SMOKE DAMPERS RELAY TRIPS TO ACIVATE AND MONITORS PAD 3 E> TIE TO EXISTING DEVICE TIE TO CLOSES EXISTING SPEAKER STROBE 1 - RELOCATE EXISTING DEVICE TIE TO EXISTING EOL REPLACE WITH 15CD SPEAKER STROBE FIELD LOCATE HVAC UNITS SMOKE MUST BE LOCATTED IN THE SAME ROOM AS THE POWER SUPPLY. REFFER TO RISER ON PAGE FA -03 FOR VOICE/SPEAKER WIRING co 0' W y o. 6`t FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 0 rn 0 M 0 0 0 p we W,_ W2 "' Z w JO Qt, w ci) < (1) W_ <C w>" CCs' i w /) �- E (/) o cnn 'Mt, ccw 4CALE: NTS DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/09/ 10 BACKROUND PLAN PROVIDED BY: ELECTRICAUINSTALLING CONTRACTOR SHALL RETURN ONE FULL SET OF ACCURATELY MARKED \OB NUMBER: J DRAWINGS FOR "AS BUILT" PURPOSES. C SHEET FA -04 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved STOCKROOM: CEILING: OPEN TO EXISTING METAL DECK ABOVE a +1V -I0 1/4" A.F.F. 5/5" TYPE 'X' GYP. BD. CURTAN WALL -BOTTOM e +10'-0" AFF.- PAINT (G1) • 0 APPROX. LOCATION OF BLOWER -VERIFY W/ MECN. DWGS. 4 ON SITE L ---J-- k7J APPROX. LOCATION ►- OF BLOWER -VERIFY W/ MECH. DWaS. t ON SITE _J BLOWER e +12'-8" ( — I '1 or I L _I_ J I, a r --I---1 v. v C. 1441 I_ __I _ 'i!i �vV •i. 1 J L_L_ v — r 1 1 L� tzitif N ,(01,/ �JD 4 „p I { i N • FcK(9 r- 1,14 1,1/ t. )tt4r- f; 1 r 1- 1_1 z- I I —I -1 w • 1/44 u 1t t 5/8" TYPE 'X' GYP. BD. CEILING e 13'-0" AFF. PAINT (GI) U DX .o 8 v1 __ . No ' 4 r ' •C_XiC r HANDICAP ACCCESSIBLE TOILE ROOM: CEILING: 5/S" TYPE 'X' GYP. BP. CLG. fa +S'-0" AFF. -PAINT 'G1' SEMI CFL.055 12e-Ezov,1 rtkc. g Lt'A.b4t EQ P-A)I lfS° y202 £'4Wr,/V6 Prn.ail (2...(404.1V 412 • ti et`b(4'i ip.L:rti(r ,t 6'r,Gic 9Q4 TotLe--r 4 t >r� p C:-Gta, M4�rl r' l t1 It 4 la 0,2,0 Ret 17 le NloJeC.: F- ( F",eL..117.5<i1-c f4Q,)C.0 (?' c-- 4-4.0 C S -r ` a Arlt 5/8" TYPE 'X' GYP. BD. CURTAIN WALL -BOTTOM 6 +10'-0" AFF.- PAINT (GI) SALES AREA: CEILING: OPEN TO EXISTING METAL DECK +16'-I0 1/4" AFF. PAINT ALL BEAMS, DUCTING, ETC. OCCURRING ABOVE +12'-5" AFF. (GI) SALES AREA ONLY s`frr-0rtit1) ftsephser 15 t t t ( 47 9.7.• iZ_ rae-Stup qty I. -r,. 5Pe7 I C;e: o r/ -r_ )c SOFFIT/ LEASE LINE 5/8" TYPE 'X' GYP. BD. CEILING e 13'-0" AFF. COVERED WITH .120 THK ALUMINUM PANEL WITH TRANSLUCENT BLUE POWDER COAT FINISH ADHERED TO 5/S" TYPE 'X' GYP. BD.- METAL TO BE BENT ON METAL BRAKE AND THEN PCWPER COATED AND INSTALLED ON GYP. BD. SOFFIT 4 CLG. G.C. TO VERIFr :5UF3 SURFACE IS ABSOLUTELY FLAT PRIOR TO INSTALLATION OF ALUMINUM PANELS. PANELS SHALL HAVE NO DISTORTION 5/8" TYPE 'X. GYP. P. CEILING e 13'-0" AFF. FAINT (GI) 41c/10 r t. ge /Z'/r, aorc4 1-4 pt// NOTE: METAL PANELING TO BE BENT ON METAL BRAKE AND THEN POWDER COATED. AND INSTALLED ON SVP. BD. REFLECTEE) CEILINC : PL4N 1/4" = 1'-0" I s`''HA) nieatflvzv 1-jr1_ztteD ALL 4- titT rLIA- L s ,,,.a L. F; 1L1 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS . 0 Witho ft Comirie lits As Noted in RE: Per The Attached Letter Tis?>e plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City. s.:' ic1ards. Acceptance is subject to errors and ct, is ,'ane which do not authorize violations of adopted :._:7,ndards and ordinances. The responsibility for the . quacy of de -Sign re :s totally with thedesigner. A. d i:ions deletions or revisions to these drawings after • tills dJ ate will void this acceptance and will requires resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by Tne Tukwila Fire Prevention Bureau. Date: � —I (0 By: / J-7 TT3 W1LA FIRE DEPARTIMIX Please call: 575.4402 and give this job No. .�:.. and exact address for shut sown or restoration aiaorov$3t NOTICE Weld stamps must be inspected before pipe is hung. Do nol paint piping prior to hydrostr;tic test approval. EMIR SOUTNCENTERILESWIELD TENANT SPACE '440 984/986 SOWTNCENTER SEATTLE, WASNRJGTON 98188 • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON . 98082-0113 PH. (425) 481-7669 SHIEKH SOUTHCENTER WESTFIELD TENANT SPACE *440 984/ 986 SOUTHCENTER SEATTLE, WASHINGTON 98188 DATE: 3-14,:- .10: I.. DRAWN:..:) A. 1: SCALE: ns i#ef t'AR172010 Tl w al14/ iz---'i e S( j f • o .(/�: 4 984 SOUTHCENTER MALL ASSOCIATED PERMITS 18-F-138 14-F-222 10-F-059 18-S-122 14-S-219 10-S-053 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: "ID►"[ ±:ra*C.e.A\G Tenant Name: Mobi Property Owner's Name: tIP eAcklWoli)- Mailing Address7P4 V l King Co. Assessor's Tax No.:Q2b2.1-11(Y b 4440 Suite Number: Floor: New Tenant? ❑ - Yes S .- No CONTACT PERSON -if there are questions about the submittal. Named , we€, c C»C\ vv� Company Namea Ac (c CQX\ 0 Mailing Address:'1Uc? \ * -M J E-mail Address:A6C�1G1(0Ifi Qiaidla �,C(� Mt V TCET III numberC2-1 Q2 City State Zip Day Telephone: ...(1-0) (Qi — 384tp City • WYi1 Fax Number: ontractor's City of Tukw. Business License number: \NI agt3( State Zip Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ ob Scope of Work (please provide detailed information): caC device, aCt.rm Sljs•ke)rr,, addun5 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R OR AUTHORIZED AGENT: Signature: Print Nam Plan Permit App.doc Day Telephone: Date: i t tS oc 1p1 -3g 8/22/14 TFD FP Form 8 44iitt*W144 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.:__ Site Address: C (>k / ",S.o 500ve I\t'r )"Y\\\ Suite Number: 49 0 Floor: Tenant Name:`QA_f O 1M New Tenant? ❑ - Yes ❑ - No �/ Property Owner's Name: V �� , - \'\A rWY ' l ri�iT Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: 3ef-D‘C Q r&o.) fl' c' 1 Day Telephone: LPS ' _ 1 p 1 7WOG Company Name: CyOki,'111 (Inc Mailing Address: & i2__\\� ' YY) 1 1, C &R °2— E -mail Address: 'e S3V 1 O Q C YOUR Yt v • (CY) Fax Number: 42. - 4Li J Total number of new/relocated devices or sprinkler heads: { 1� Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): sysodi-Aef \neock PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O/R�AUTHORIZED AGENT: Signature: (•Ss\an` cX _ c\ICAAA•g42n 36CS\CA 19111W1) Print Name: Plan Permit App.doc Day Telephone: Date: (9 1241 � 9 1/2/13 TFD FP Form 8 CITY OF TUICWIILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review **PLEASE PRINT** SITE LOCATION Site Address: q51/ E(501-IvinW rna Suite Number Floor Tenant Name: / (/ I °i New Tenant? ❑ - Yes Q - No Property Owner's Name: (,)Q 51'-6 Q 1d t t ( caloppuloa/ (,(itl Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. King Co. Assessor's Tax No.: Name: 1 -fra� Day Telephone: 46744/ -764 Company Name: C 17.t pvo f W?nn 1 Yl C Mailing Address: t" o 64 / 2, 1 3 m/ (/ n v/ 9) (i2 City E-mail Address: Fax Number. Contractor's City of Tukwila NICET 1II number. Business License number: Total number of new/relocated devices or sprinkler heads: x Valuation of Project (contractor's bid price): $ f "J ) -i •� Scope of Work (please provide detailed information): kd fl vacls rel DC -rrt q hjx 6 S' PERMIT APPLICATION NOTES 9 valise of Coastraction — In all cases, a value of construction amount should be entered by the applicant This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. State Zip Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its i or ifthe work authorized en the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause deiuonsttated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZE© TO APPLY FOR THIS PERMIT. BUILDING OWNER OR1A/Uj TH�ORIZED AGENT: 111/ r , w Sianature�� `` Date: Print Name: c-IJ� I� -qua u,% 1 r c e V / Day-Tdeoone: Y-57 / ` 7 U! Plan Permit App_doc 822/14 TFD FP Form 8 ' SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application • accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address: 984/986 South Center Mall, Tukwila, 98188 Suite Number: 42°1 Tenant Name: Soles Shoes New Tenant? ❑ -Yes 0 - No Property Owner's Name: Hinkle Construction Mailing Address: 1905 N Williams, Mesa AZ 85203 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Casey Walsh Day Telephone: 206.331.6206 Company Name: Guardian Security Systems Mailing Address: 1743 First Ave South, Seattle, WA 98134 E-mail Address: cWalsh@guardiansecurity.com Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 2000 City State Zip Fax Number: 206.628.4e90 Scope of Work (please provide detailed information): Adding ci devices to an existing fire alarm system PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name.Casey Walsh Plan Permit App.doc Date: 09/25/2014 Day Telephone: 206-454-9652 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Sole Shoes 984 Southcenter Mall Permit No.: 14-S-219 Date: October 2, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: T -Mobile 984 Southcenter Mall Permit No.: 18-S-122 Date: June 22, 2018 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2' inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Shiek Shoes 984 Southcenter Mall Permit No.: 10-S-053 Date: April 1, 2010 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2007 Edition. FI ALARM SYSTEM ADDITI TUKWILA, WASHINGTON SHEET \UMBE SHEET TITLE FA -01 SYSTEM \FORMATIO\ FA -02 TYPICAL WI I\G AND. MOUNTING DETAILS EA -03 SYST V CALC U LATI O \ S AN D SINGLE LINE DIAGAV FA -04 ERE ALAS vl SYSTEM P _AN SHEET INDEX 'tp' Without Comments o As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: i By: WI 'WXWILA FIRE. DEPARTMENT' Please call 206-575-4407 and give. this Fire,Permit No. nd exact address for shut - :own or re.oration approval. SCHEDULE A \D CO\DUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPUFPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPUFPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPUFPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JJRISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVIIE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY E 3 2 2 1 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY E (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 3 FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TS M -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A Ni A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVEL r3 ursa;•r • ...27Esi r_. T -MOBILE SUITE 440 macy 3 SEARS 7 T SITE PLAN PAD JUN 13 2018 TUKWILA FIRE Gc ,'3vv (if) L _1 l Cfs 03 is ii LL; RELEASE/REVISIONS 0 Lu DESCRIPTION SHOP DRAWINGS L1 0 co el K 0 te• t' co - co 0 t/) Z 0 W Q Jo Iz z O I � UJ LL i- 0) CALE: NOT IC; SCALE - DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07/11118 BACKROUND PLAN PROVIDEu BY: Proprietary and Confidential, Cop ri•ht 2013 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER: :)425.)--1 SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ DEDICATED E1dERGENCY TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE FOR ADDIDCNAL SPECIFICATIONS SEE PRCOUCT DOCLUENTATION. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC ISIX.A(TE FR DNSRIGRDIkiDINfi TO NEXT ADDRESSABLE (+ DEVICE STIP IF LAST DEVICE FRf1N XLS CONTROL. PANEL OR PREVIOUS ADDRESSABLE DEVICE r lm GR J D .I lr J HTRI-R 0 n7 0 O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE ORD N L 0 PAD -3 00 INPUT INPUT TROUBLE NACI NAC2 NAC3 NAC4 AUX + — 1 2+ 2— 2 NC C NO + — + — + — + — + — 0 (+) NAC 3 CIRCUIT NAC 2 CIRCUIT CEILIN TILE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (-) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE 1+ 0 (+) (+PREFROM XLS CONTROL PANEL OR -(4- PREVIOUS VIOUS ADDRESSABLE DEVICE END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH GROUND 0 0 0 Ln HTRI-R OSTATUS LED Co 0 N.O. 0 COM 0 N.0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 MUSIC HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY TO NEXT DEVICE OR J END OF LINE TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TINGTEMPERATU E: +32'F 0'C TO100'F 36C) HUMIDITY. 93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -- FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE rDATA IN( )> SI DATA IN(+)> DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION NTH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL > TO NEXT ADDRESSABLE DEVICE TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE HFP-11 TB1 CXX>Opp® O 110 NO COM NC TO FAN SHUTDOWN EOLR 470 i 0 SWITCH + - INPUT LED TSM -1 0 0 TO NEXT ADDRESSABLE DEVICE 0 -®I /1/1/ 2 O U NO ® COM HTRI-R "C 0 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTI❑N BOX \ MOUNTED ON CEILING FLEX \ JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 0 TO NEXT DEVICE ----CADDY BAR of SMOKE DETECTOR-- of ETECTOR— SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Jr) co C JASHINCTON 174.3 IST AVE. SO., SEATTLE, 0' cs co CV O CV LIJ RELEASE/REVISIONS (REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 07/11/18 I oz <<<< .1 CD CD z c O W 2) O) cliow2EZ 000wcn yv cC r J =J LL F— op co 0) :fat AND MOUTNING D �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07/1 1 /1 8 BACKROUND PLAN PROVIDED BY: ._JOB NUMBER: 3425-1_} SHEET FA -02 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved A B C D E F G H J K FIRE ALARM BOOSTER Project: T -MOBILE SUITE 440 Panel: EXISTING PAD -3 REMOTE Date: July 11, 2018 Module/Device POWER WSCM BOOSTER Qty SUPPLY T.I. POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 2:1 -1 -MC -CW @30cd 131 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 3735 <<<<< Total(A)= 15 Total(B)= 3875 CALCULATION Total current ratings of all devices in system (line A + line 6 + line C) 15 3875 Total current ratings con'erted to amperes (line D x .001) 0.015 3.875 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 ZR -MC -CW @licd 69 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 1 0.3227875 Add lines G and I Total Standby and Alarm AH 0.6827875 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.819345 5 TOTAL mA= 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: T -MOBILE SUITE 440 WSCM T.I. Panel: EXISTING PAD -3 REMOTE POWER SUPPLY Wire Resistance 2.58 Date: July 11, 2018 CURRENT TOTAL= 3735.00 _ (. � 1 ►�! r° 1 . t r, s fi y 'i ;d o C� fjgv-:g fir• i 76, r' i. fi4 ::: iii + • io r` r� { 2 lzH-MC-CW @15cd 87 174 DATE 07/11/18 2:1 -1 -MC -CW @30cd 131 0 2 <<<<< '21 -1 -MC -CW @75cd 222 0 1 ZH-MC-CW @95cd 292 292 1 ZR -MC -CW @licd 69 69 1 ZRR-MC-CW @75cd 200 200 DEVICES 5 TOTAL mA= 735 14 281 22.93 735 Total Wire Resistance (R) (WL * 2 ) * (Rift) 1.45 Total'Device Load, Amps (1) (Total Cct Load) 0.74 Voltage Drop (E) (E= I R) 1.07 ff, - .. 4 iilP �lbr �' Voltage- - - 24 - E)fy 22.94 jEOL je ,+{ y7 is IA4 S Y3$i L i f. 3 • 1 ,' .3 ...... yy.. �$'j _ �1i . y { ' }L}9 -- 1- ` t,'. ^ '�ua�i.. :?,Y i'ir},:. �''+y S••• i!'�' 3��i f(.=� E-' '} @ Y }_ ,. i : ai � k •:f;- < «�EiY , - - DEVICES MAXIMUM LOAD TOTAL mA= 1500 24.00 1500 Total Wire Resistance (R) (WL * 2 ) * (Rift) 0.00 Total Device Load, Amps (1) (Total Cct Load) 1.50 Voltage Drop p(E ) {E=1*R) 0.00 EOLVoltage 24 - E) 24.00 * _ ^ ^4 . , 5`i • --?ii zi8 ._ <E,bl�..x II1..'uY •mY.4:} i 1! i , s.., Y. DEVICES MAXIMUM LOAD TOTAL mA= 1500 24.00 1500 Total Wire Resistance (R) (WL * 2 ) * (Rift) 0.00 Total Device Load, Amps (1) (Total Cct Load) 1.50 Voltage Drop (E) (E= 1* R) 0.00 EOL Voltage 24 - E) 24.00 CALCULATIONS BILES FACP' Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000. FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps EXISTING TENANT JUNCTION BOX S3-1 S3-2 S3-3 S3-4 S3-5 15Cd 95Cd 15Cd 15Cd 75Cd SINGLE LINE DIAGRAM EOL S3 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. WASHINGTON Lit RELEASE/REVISIONS REV. BY: I DMG DESCRIPTION SHOP DRAWINGS DATE 07/11/18 2 <<<<< c z �- co P0) o�z Lu -w °° cc �.1 crW 0 0� LL F_ co 0) c 0 0 z LLJ 0 z Z5 0 0 CALE: NOT TO SCALL -Th DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:07/1 1 /18 BACKROUND PLAN PROVIDED BY: ,,JOB NUMBER: 34253-1} I SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved CORRIDOR D TO EXISTING TENANT ( 0 JUNCTION BOX 3 CONFERENCE S ADJACENT TENANT ROOM BACK OF HOUSE S3-2 95Cd EXi. r, TOILE OOM S3-1 �5Cd INVEN ORY S3-5 EOL 75Cd S3 SALES AREA FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. CORRIDOR FIRE ALARM SYSTEM PLAN MALL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved eft HASH I NG I ON RELEASE/REVISIONS REV. BY: 0 0 1 DESCRIPTION SHOP DRAWINGS J DATE cO 0 0 - 'Tr co Z co p H Y— F- 5rn <J m W 2z O,W(/) c2cc W'S J I_I_I j§ On LL f— CT) �CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07 1 1 1 8 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 34253-1) 1 SHEET F/' 04 O Without Comments O As Noted in Red -pc Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standands. Acceptance is subject to errors and omission ich do not authorize Ipolations of adopted standards al ici ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions of revisions to these drawings after thls date will void tris acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date:(o-D-3--1 By: 1.k.ONILA FIRS DEPARTMENT ',2.ast call 206-575-4407 and ;;We this Fire Permit No. kC-- exact address for shut - ,:.awn or restoration approval, CONFERENCE ROOM ADJACENTTEN j 716 49 Cr 8'-0" RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C—CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING EQ. STEEL. JIXST/TRUSS HANGER DETAIL NTS F P101 .. V tr_iairpgsa..._.-.:,....:L.., =2 L1W Pi.... a BACK OF HOUSE 4.04111fAt COR.RIDOR. EXISTING TOILET ROOM. CORRIDOR GYP 111 F P101_H 11 '-0" , 10'-0" GYP..-. P101 F P10t • 1/4" = 1'-0" PLAN. Design per NFPA 13 — Ordinary Hazard Group 2— 130 SF MAX All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions • 4— Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x % • 4 — Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 • E — Existing no change g- TOTAL MALL PUBLIC RESTROOMS ARE LOCATED 100 FEET AWAY. REQUIRED DISTANCE PER IPC = WITHIN 300 FEET • Pianist om ..“Dr.t12,2M • !sink, • Ws urn t. • sfsismss •,, • ITI! • tni. 1411 • Cloud Crififsity •••• • • : • FlexHead Sprinkler Drop . .• • • • • • , . . .,..1,115,405i4Oorrugated tainless steel hose with stainless steel braid • available in 2'. 3',4',5' & 6' legnths . • . -1364. ... ;s; • Multi -Port Bracket • • - • • .• • • • • .• Adjustable Hub • " • : FLEXHFAD INDUS =1711Tear • • C Flexhead omniercial Ceiling Unit T-1.3 ar Ceiling installation Model #2024,2036,2048,2060,2672 IT • -WNW • .1. •essr I. • ISY Sikesi tate • af ar • Seafood try ketpl*Ce • Css• 3.•••••: sees. 503 • Witt Gaisti. • Orli, : • ...Vs • 2oV• ass/ .4;1 • Me 141 01,1•••Int • Ma rie s • 3.iisir sasket • •a• +.•••e:ifif . r • 3 . •oct • (Az Sas • [Isle us: • foal torle• • • • siss•san f tirtriss . 20 • 2102.2.2. • usise. • ass,s, : • Iasi.* _ . • Odno /Opts • • stpaths • LS UbN12) C ••••• • WO. SI WS‘hPVC:21 • 2 - • 411,:y • sagr•••0 cosecs./ • Ks Cl•Stlisn‘ flars •...O." C2iturs • <Cary I • JCPt ntrey • JCI'enney • • thr Ceti • Stilt WO f• reef), ',site • S's • 0.100.1 ,..sSI,S2 • •14C • c c2•4•1-422.1 Csortsm lois 4. eaCk1 • bars • .•oiku • ffsrsf• • f Ci C, 13 ,.• • fee,i ill, 1 Missies _ • Si, C s - ; Pckewie KEY PLAN LE'/EL 1 OF 3 wf. • ‹tcf••••• • ef 1 ire IP es•fsiwr MMMMM •Fg•Anemiumu, cerrrortanT Noy FIRS PROTECTION SPRINKLER SYSTISNIS arearicasatning 1 V John J. Abel 9780 -069I -CG Level 3 Cie* File Plated/on, Inc. 0 F'13044 SIgnatura re 111111111151111101510111:11610t111217811a1211111101612317011111S110110 MMMMM • CROWN FIRE PROTECTION. INCORPORA TED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 Pti. (425) 481-7669 0' n T -MOBILE 984 SOUTHCENTER MALL • SPACE 440 AID TUKWILA, WA 98188 - -TUKINI-LA7 2:118RE 7-29(76) 1 ' • iLA DATE: 61 ti 1 y 1 DRAWN: 05- SCALE: 6-4 SC31, SFIGS FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON 'EC Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans ha»e been reviewed by The Tukwila Fre -,, evention Bureau for conformance with current City ;-;cndards. Acceptance is subject to errors and missions which do not authorize violations of adopted �andards and ordinances. The responsibility for the -adequacy of design rests totally with the designer. additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire cPrevention Bureau. Date: /0 -7- l By: NOTICE A completed, signed, Tirkwii� Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarrn and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. address for shut - approval. and down or SHEET NUM3ER SHEET TITLE FA -01 SYSTEv1 INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEIv CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX WISE SCHEDULE A\3 CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCJIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 1 1 1 1 3 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP ® AIR DUCT HOUSING D W/ SMOKE DETECTOR FDBZ492-HR W/ SIEMENS DUCT HOUSING HFP-11 DETECTOR HVAC DUCT WORKS HT -M SINGLE INPUT INTERFACE MODULE HTRI-M SIEMENS 4S BOX VERIFY IN FIELD TSM DUCT DETECTOR TSM -1 SIEMENS 1 -GANG BOX VERIFY'" TEST SWITCH IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S BOX CEILING FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX CEILING 0 JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N /A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND macys 4 LEVELS 250,407st \`I NORDSTROM !j 3 LEVELS 171,275st mE' i1£ P.iRE RDS StWR Y COW rT5 I I ce'e ru:o Taro ruoo CRUKK_ei ReD PIOBO» idea DUSO MNG COWINY I,DR ART .EWRERS 3q SEAM SOLE SHOES #984/986 / SPACE #440 PAID SEP 2 2014 TUKWILA FIRE aD 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-651+5 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 09/24/14 2aa«< 0 OD W Z g co (13/5O) Cf) o 2 MCD = W cr W ")W‹ O U, (W- OO co 11.1 (1) >I10) TO SCALE~ Z 0 0 u. �CALE: NOT DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/24/14 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN cc PO Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved .OB NUMBER:10177-1 SHEET FA -01} THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120YAC-60HZ DEDICATED El4ERGfNCY '' NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30WC kliN TO NEXT DEVICE T LASTADDRESSABLE a FROi XLS mNTRDL PANEL(+ Cit PREVIOUS ADDRESSABLE DEVICE GRA a HTRI—R 0 O 0 O NO1E SSEEEE PRODUCT DDOCUMAL EN AT 11O S C -CABLE C -CABLE 0 0011 ORD N LL 0000 CI PAD -3 oo ill INPUT INPUT TROUBLE NCI NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - (-) (+) 2 SPARE SPARE SPARE FROM PREVIOUS ADDRESSABLE DEVICE 2 (-) HFP-11 TB1 ®® NO COM NC 2 2 TO FAN 2 SHUTDOWN EOLR 470 0 0 SWITCH + - INPUT LED TSM -1 HTRI-M RED BLK ORG ORG GRN + TO NEXT 2ADDRESSABLE DEVICE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL DUCT DETECTOR/HTRI-M MODULE/TSM-1 SWITCH WIRING DETAIL (+) HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32' F 0' C TO 100' F (38' C) HUMIDITY: -9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR > FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD % SMOKE DETECTOR BASE REAR VIEW (-) > TO NEXT 1 I . ADDRESSABLE (+) SMOKE DETECTOR WIRING DETAIL HARD LID CEILING <440kT> 0 0 SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING DEVICE SUPPORT BRIDGE 4° SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX A t.re.?tr./ aa.dSem.. JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 i 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m D DESCRIPTION SHOP DRAWINGS DATE 09/24/14 z as<<< 1 0 w 0 Z �Q co O Cn vJ co W :10Q 200 = w Iz z w w'� cc 0 O 5i5 C/) Q �O� u- 0co)- 0 co 0) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/24/ 14 BACKROUND PLAN PROVIDED BY: \OB NUMBER:10177-1} SHEET FA -02 Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved \ 4 r ¢ A.�' � ,k., :,A,ti ✓ia1 A♦Y'.fl ,".m r"Q,,":'1 �P1;W'' �fl f m.A 17� ?rj4i � �M ��� 5 h i� •rv., r �^, '�:�,"/ ne ": , Y3 : ,, ,., Y,... ^.,..,, v ...": ...:'i. , rv✓b .. ,.'r .'a ��"' 1 kY xN y , ., ry ,. , „ @ �Gd\1 ; 9S3 4 s4!,S J!P ✓ , ;wire Resistance 2.58 i CURRENT TOT -A-1:=1669.00 rl I 1 'L ph I , (1 ,. , �. 'Y • Current Load: d'. r kr# Standby: Alarm: :,!. ! ^N y t '� y';;�.;;N f I I Y '�r,,,,. 4�! GI '.9 �I h1 M d.',. `. ZH-MC-CW @30cd 131 ZH-M C -CW @75cd 222, 4441 Device Type Qty Amps Total Amps Total Amps HFP-11 Detector 1 0,0015 0:0015 0.0015 0.0015 0 669 j FDBZ492 Duct Housing 1 0.0001 0.0001 0.0500 0.0500 0.030 HTR -R Module 1 0.0010 0.0010 0.0010 0.0010 0.069 HTRI-M Module 1 0.0015 0.0015 0.0015 0.002 0.111 0.777 ZH-MC-CW @75cd 7 0,222 0.2 1.400 ZH-MC-CW @95cd 0.0041 Amps 0.0540 Amps ":.,„,':. •, , Cs, :�mi.. bu. ..i.. a>,�:'„ �rr .. a, . .,,.., �"� ,w ".� .,., f � „��,.,1,, .A. �, £ ✓,ii�.i�a&�,,„,, .„{r'. .. .'r^t,.a .,�.a• ..., . � ;,',. 4 r r. .N., , . , A..w,i '1,'�..{.,, 5�,, ,,.r„,1 ., A.N r,�,„C. rf. ,Yrv„.^.ti4.«� ,,X,x{i >„r'i �,...,, �y �fl f m.A 17� ?rj4i � �M ��� =x«. ,Y .},,' � .,,9.'1 x,,,,,. .c +r,� , ,:; � i f�;.yy�y► �% a r ,�, I. ,;. �!y �,,4 x}�x'' iy� S , fl�w•��`, � I{M,a, �� J,,. � 9� r A r.,„ MI �� ,. t� �a�. $yi�w�' A� 1,y"�� ]k� � ,� �� 1r � � 1iJR'r,'����' ,rir ir;,;;�I N qxt i1 ;wire Resistance 2.58 i CURRENT TOT -A-1:=1669.00 rl I 1 'L ph I , (1 ,. , a 'Y • ',.. ,, 7 1'w„9:.; F ', , �� • ,..” , ' 4 E ,� Curie d'. r kr# 9 ', i'. 1 r f;;! �5,,, r'9'@” P:kl,k' ! r r r,u :,!. ! ^N y t '� y';;�.;;N f I I Y '�r,,,,. 4�! GI '.9 �I h1 M d.',. `. ZH-MC-CW @30cd 131 ZH-M C -CW @75cd 222, 4441 Device Type Qty Amps Total Amps Total DEVICES ZR-IVIC-CW @30cd 111 ,5 TOTAL -in' iA= ` 0 669 j 14 159 Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW @1 c 16 0.087 0.069 1.104 Z1 -1 -MC -CW @30cd 7 0.131 - 0.67 0.55 23.45 0.111 0.777 ZH-MC-CW @75cd 7 0,222 0.2 1.400 ZH-MC-CW @95cd 0.292 0.264 ZR -MC -CW @'IScd 15 ; :: 0:069 0.069 1.035 ZR -MC -CW @30cd 1 0.111 0.111 0.111 0.111 0.141 Amps 4.457 Amps Standby Current Load: :' 0.141 Amps For 24 Hours = 3.384 Amp -hours Alarm Cur en Load: ' 4.457 Amps For 5 Minutes= 0.374 Amp -hours 25% Derating= 4.698 Amp -hours Total System Current Load: 4.698 Amp -hours �G Y .� „ Ni�'� wRECOMMENDED D��I�11��1 ' 1� w � x } � }, ° rim ^'', ,�1,� ;�"r' ,,. ;�►�� `" wxr�� r%'�"r4 d 1.'',"AI t, 1 ,�,'',s 1s r;✓ .4''{.'>:',,'+r, , � t TO NEAREST EXISTING DATA LOOP (BACK -OF -THE -HOUSE) TO EXISTING POWER SUPPLY (BACK -OF -THE -HOUSE) SYSTEM CALCULATIONS S1-1 S1 -2 S1 -3 S1-4 S1 -5 15cd 15cd 15cd 75cd 75cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 'REV. BY: I Notification Appliance Circuit Detail SOLE SHOES PROJECT: Panel, Date: j EXISTING PAD -3 POWER SUPPLY September 24, 2014 ;wire Resistance 2.58 i CURRENT TOT -A-1:=1669.00 rl I 1 'L ph I , (1 ,. , a 'Y • Vhl: ! ; C • 1ZH-MC-CW @15cd 871 87 2 ZH-MC-CW @30cd 131 ZH-M C -CW @75cd 222, 4441 2 ZFI-MC-CW .95cd 292.. !ZR -MC -CW @l5cd 69; 138 DEVICES ZR-IVIC-CW @30cd 111 ,5 TOTAL -in' iA= ` 0 669 j 14 159 23.45 3 .. 669 Total Wire Resistance R) '( WL *2 ) * (R/ft) 0.82 Total Device Load, Amps (1) ,Voltage Drop p ( E ) (Total Cct Load (E- I R) 247-i) - 0.67 0.55 23.45 EOL Voltage SYSTEM CALCULATIONS S1-1 S1 -2 S1 -3 S1-4 S1 -5 15cd 15cd 15cd 75cd 75cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 'REV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 1 09/24/14 0 a W o � �r J W zUW�t ao --� 0 C� (ocO) Z W< :JO CJ) = W Z z Cly < W 2 w CJ) —1 cc Og ; 0 IA 0 cc cr) I- co I- 0 U co a) w (J) >- Cl) 4-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:09/24/14 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM .10B NUMBER:10177-11111} SHEETff FA-03 Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved \ } EXISTING STOCKROOM & ACCESS. TOILET ROOM TO REMAIN WITH NO CHANGES (SHOWN SHADED) EXISTING STOCKROOM TO REMAIN WITH NO CHANGES: CEILING: OPEN TO EXISTING METAL DECK ABOVE @ +16'-10 1/4" A.F.F. WALLS: EXISTING 5/8" TYPE 'X' GYP. BD. TO REMAIN FLOOR: EXPOSED CONC. TO REMAIN -•a FURR OUT WITH 1 5/8"-20 GA. METAL STUDS @ 16" O.C. WITH 5/8" TYPE 'X' GYP. BD. (FLR. TO CLG.) 4'- 4' - II H NO CHANGES 0 EXISTING 12'-0" HIGH STOCKROOM SHELVING w/ SEISMIC BRACING TO REMAIN WITH NO CHANGES (TYP.) TO NEAREST EXISTING DATA LOOP (BACK -OF -THE -HOUSE) TO EXISTING POWER SUPPLY (BACK -OF -THE -HOUSE) TEL b EXISTING 12'-O" HIGH STOCKROOM SHELVING W/ SEISMIC BRACING TO REMAIN (TYPICAL) S1-4 mei 75cd TSM EXISTING MGR. DESK 6" WIDE X 6" HIGH ROOM IDENTIFICATION SIGNAGE WITH BRAILLE CHARACTERS @ +60" A.F.F- SEE A-6 FOR ADDIT. INFO. EXISTING HANDICAP ACCCESSIBLE TOILET ROOM TO REMAIN WITH NO CHANGES: CEILING: EXISTING 5/8" TYPE 'X' GYP. BD. CLG. @ +8'-0" A.F.E. WALLS: EXISTING 5/8" W.R. TYPE 'X' GYP. BD. FLOOR COVERING: EXISTING 12"X12" CERAMIC TILE & 5" HIGH INTEGRAL COVE BASE T 1 T 8 STAINED WOOD MIPROR FIXTURE SEE 2/A-5 (TYP.) 48" WIDE X 8" DEEP STAINED WOOD SHELVES MOUNTED ON CONCEALED SUPPORTS SEE 3/ A-5 (TYPICAL) ACCESS'BLE NEW CASHWRAP TOP @ -34" A.F.F 1 SEE 1/ A-5 48" WIDE r. 8" DEEP STAINED WOOD SHELVES MOUNTED ON CONCEALED SUPPORTS SEE 3/ A-5 (TYPICAL) S1-5 75cd 1 T SL FREE-STANDING SHOE DISPLAY w/ INTERNALLY ILLUMINATED WHITE PLEXIGLAS BLOCK SEE 5/A-5 FREE-STANDING SHOE DISPLAY w/ INTERNALLY ILLUMINATED WHITE PLEXIGLAS BLOCK SEE 5/ A-5 60'-9" EXISTING SALES AREA: CEILING: NEW 5/8" TYPE 'X' GYP. BD. © +11'-0" A..F.F.- PAINT 'G1' WALLS: EXISTING 5/8" TYPE 'X' GYP. BD.- PATCH & PAINT (G1) FLOOR: NEW 20"X20" PORCELIN TILE 'PF -1' WITH ZERO TOLERANCE GROUT JOINTS WITH 6 1/2" HIGH 'PB -1' TILE BASE THROUGHOUT SALES AREA. GROUT TO tv1APEI NON SANDED 09 GRAY K EXISTING MALL I CERAMIC iILE FLOOR PLAN - FIRE ALARM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. EXISTING 1/2" THICK CLEAR TEMP. GLASS SET 6" HIGH S.S. GLAZING BASE & 4"x4" VERTICAL MULLIONS WITH 1/8" AIR GAPS- BUTT JOINT TO REMAIN (TYP-BOTH SIDES) v ti CC 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION I SHOP DRAWINGS DATE_ 09/24/14 2CCaaC 0. O IA co Z O03 O Q T (f)o Ci) o) W ZIp = w frz w pc WQ_I U� o 02 U- co i- 0) d' 0) W CC ilm SCALE: 1/4”=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/24/14 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 1 01 77-1, SHEET FA -04 1 Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved Without Comments As Noted in Red Per The Attached Letter DEPARTMENT Please call 206-575-4407 and Sive this Fire Permit No. 1�!-S-ata and exact address for shut- down or restaraxi approval. plans have been reviewed by The Tukwila Fire (tion Bureau for conformance with current City _yards. Acceptance is subject to errors and :;:ons which do riot . +jl:norize violations of adopted .:ards and ordinancerF, The responsibility for the ,.,uacy of design rest{ i:otally with the designer. ',.lieions, deletions s::•:• r:: ktisions to these drawings after ; s date will void t ,K.:“c eptance and will require a :suomittal of rr: vis:_:.' %t; Ewings for subsequent approval. .,Inas acceptance is sunject to Meld test and inspection by me Tukwila Fire Prevention Bureau. Date: /0 Bv: I 1 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS 3/e' ALL THREAD ROD PIPE SWIVEL RING EXISTING STOCKROOM 4 ACCESS. TOILET ROOM TO REMAIN WITH NO CHANGES (SHOWN SHADED) OTE: LI EXITWAYS ARE TO BE ILLUMINATED O AT LEAST ONE FOOT CANDLE AT THE LOOR LEVEL. EXISTING STOCKROOM: CEILING: OPEN TO EXISTING METAL DECK ABOVE • +16'-10 I/4" AFF. NEW 5/8" TYPE 'X' GYP. BD. LIGHT COVE +II' -8" AFF. TAPE, FINISH 4 PAINT 'GI' WHITE EXISTING 5/8" TYPE 'X' GYP. BD. CURTAIN WALL:BOTTOM a +10,-R" AFF.- PAINT 'GI' EXISTING r2 ALUM REVE. TO REMAIN APPROX. LOCATION OF EXISTING BLOWER TO REMAIN EXISTING CCt PACT FLUOR LIGHT FIXTURES TO BE REMOVED 4 REPLACED WITH NEW LW DOWNLIGHT (TYPICAL OF 1) EXISTING 5/8" TYPE 'X' GYP. BD. CEILING a 13'-0" AFF. PAINT (GI) • FlexHead Sprinkler Drop . Corrugated stainless steel hose will: stainless steel braid ravailable in 2', 3',4',5' & 6' legnths . . EXISTING LEASE LINE Multi -Port Bracket APPROX. LOCATION OF EXISTING BLOWER TO REMAIN EXISTING 5/8" CEILING a 13' - EXISTING .120 WITH BLUE PO TO REMAIN TYPE 'X' GYP. 1315. 0" AFF..COVERED WITH WK ALUMINUM PAi NML L ER COATED FINISH EXISTING 5/8" TYPE 'X' GYP. BD. CEILING 13'-0" AFF. PAINT (GI) .. • Adjustable Hub • • Flexheadr ommerciaCeiling Unit T -Bar Ceiling Installation • Model ##20 4,2036,2048,2060,2072 ACCESS P SEE 1/A-2 •'STRIPE' IGWTS' .• SOLE SHOES SOUTHCENTER U1ESTFIELD TENANT SPACE 0440 984/ S% SOUTHCENTER SEATTLE, WASHINGTON 98188 A a a a a a1. a L EXISTING 5/8" TYPE 'X' GYP. BD. CEILING e 13'-0" AFP. PAINT (Gl) EXI TING HANDICAP Ac;.CC'ESSIBLE TOILET ROOM TO REMAIN WITH._NO CHANGES: CEILING: EXISTING 5/8"TYPE 'X' GYP. BD. CLGx. e i '-0" AFF. 5/8" TYPE 'X' GYP. BD. CEILING a +12'-0" AFF.. FINISH 4 PAINT (GI) NEW 5/8" TYPE 'x' LIGHT COVE a +II' -8'; AFP TAPE, FINISH 4 PAINT 'GI' WI-IITE EXISTING SALES AREA; CEILING: NEW 5/8" TYPE. 'X' GYP. BD. g +Il' -0" AFF. PAINT 'GI' b-m'Si SI1aa--M-se------- WASHINGTON STATE ERTIFICATE OF COMPETENCY ECTION SPRINKLER SYSTr ohn Ales 9&7:0591 -CG Level3 r Pt4,41 Fire Protection, Inc. i ' O FP044L Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart 0 Empires 19t3i/14 ---a o 1— Add Globe Model GL5615 Quick Response 155° Brass Uprights 1/2 x 1/2 o 9 — Add Reliable Model G5-56 Quick Response 165° Concealed Pendants 1/2 x 1/2 (white) • E — Existing no change CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 SOLE SHOES SOUTHCENTER WESTFIELD TENANT SPACE *440 984/ .986 SOUTHCENTER _SEATTLE, WASHINGTON98188_ DATE: r:; ..t3. I'4 DRAWN: SCALE: PAID SEP 24 20141 c.n TUKWILAFIRE. to l SHIEK SHOES FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL), RISER FA -04 FIRE ALARM SYSTEM FLOOR PLAN WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD *14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD *16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD *14 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD *16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR *14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDIO TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED *18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO *16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL 1W CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-112" .82 SQUARE INCH 2 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT 3 2 2 1 EX FATP FIRE ALARM CONTROL PANEL MXL SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP TRI -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD TRI -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP BOX VERIFY IN FIELD DUCT SMOKE DETECTOR AD2-2P SIEMENS HFP-11 DET DUCT HOUSING VERIFY IN FIELD SMOKE DETECTOR (PHOTOELECTRIC) HFP-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM E 5 STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM PAM MULTI -VOLTAGE RELAY MODULE PAM -1 AIR PRODUCTS 4S BOX VERIFY IN FIELD FIRE SMOKE DAMPER F.B.❑, N/A VERIFY IN FIELD FATC EX JUNCTION BOX F.B.O. F.B.O, N/A VERIFY IN FIELD C> WATERFLOW SWITCH F.B.0.__ F.B.O. N/A VERIFY IN FIELD O TAMPER SWITCH F.B.O. F.B.O. VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 0 01 0M co coo coo co co _! 0) W adz (i) oC CD U),rz: tu) ctft) w ¢ I� () LL ‘ALE: 1'=1 /8" DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/09/1 0 BACKROUND PLAN PROVIDED BY: J0B NUMBER: 14 SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCT OVER 3' WIDE; SAMPLE TUBE MUST GO 11 -IRU THE DUCT AND BE CAPPED. BEND OR OTHER OBSTRUCTION BEND OR OTHER OBSTRUCTION DUCT DETECTORJ LOCATION TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE 120VAC-60HZ DEDICATED EMERGENCY NOTE: FOR AI:CM:NAL SPECIFICADONS SEE PRODUCT DOCUNDITATION. SUPERVISORY PONT FORM 'C. RELAY CONTACTS LED 'CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL-(+ OR PREVIOUS ADDRESSABLE' DEVICE 11) 0 GRIN :5) MODEL: HTRI-R Rti N 00 OD 00 0 PAD -3 0 INPUT INPUT TROUBLE NAL:INAC2 NAC3 N4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 3.15k EOL IT! TYPICAL WIRING FOR HTRI-R MODULE (PAD -3 TRIP) SCALE: NONE rl 1,7,:j1,MIM TO THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE W111-1 NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. BATTERY TUBE OUTLET SAMPLING TUBE INLET— SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD -2P DUCT DETECTOR SCALE=NONE SPEAKERISTROBE r ...1 11 II jEnmL I' • .....011Mins... . - I 111 1111 — — ::':.::' .°.. 1 1 1 I i h 1 I I i li n1S. F7-1. rf' am IN C Agall 7j. } 0 1110 . 0 - • r -131 11 . 11; IDEp s 1 i.f.t) •::' \\s\j 7..h ! 2 —1 L21.!'"'?ii.:1!67.1*/ i / 4.'1 • _ I —.....--- FROM PRECEDING STROBE APPLIANCE OR SYNC MODULE (—) NAC -4 NAC -3 , NAC -2 (+) NAC -1 FROM PRECEDING SPEAKER< (+) OR FIRE ALARM SPEAKER CIRCUIT CONTROL PANEL (FACP) SPEAKERISTROBE AND STROBE WIRING () (+) STROBE CIRCUIT SPEAKER n -DI ii 11 1.-1, • o I - _____-----------....„. 0 I rf:1 ,1 I I- , SHOP DRAWINGS 1 1 I i 1 0 zz., 0, 0 --.. p.) i ' I h [:::°j (T. F f ?1,. - o o o o +SIAM - am IN C Agall 1fL'_.' Tf - -. - .1' 0 1110 . 0 - • r -131 11 . 11; IDEp (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERATURE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS LISTED FOR MR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE ---> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE [DATA IN (—) > DATA IN (+) > REAR VIEW (-) > TO NEXT >--4 ADDRESSABLE HFP-11 SMOKE AND DB -11 DETECTOR BASE-VVIRING DETAIL LABEL SCALE STROBE SPEAKERISTROBE 1 I I ?1, TROBEn TROB IRCUI (+) ' DEVICE > STROBE CIRCUIT FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0rri (+) WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR FYITH SHIELD #18 FPUFPLR RED (JACKET) 'CONTACT RATINGS 4.0A 0 t25VAC 4.0A 0 30= FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 GENERAL NOTES (—) TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE 1. SPEAKERS ARE TAPPED AT 70.71/4 WATT. 2. STROBES CANDELAS ARE ON THE FIELD DRAWINGS. 3. CHECK CUT SHEETS SUPPLIED WITH PARTS BEFORE HOOKING -UP. 4. ALL ALD LOOP WIRES MUST BE IN METAL RACEWAY. 5. ANY ALD LOOP WIRE THAT GOES TO FANS 1 DAMPERS THAT ARE PART OF PRESSURIZING OR VENTING SMOKE CONTROL, NEED TO BE IN METAL RACEWAY AND 2 -HOUR PROTECTED ( CI CABLE OR ENCLOSED IN 2 -HOUR CONCRETE OR SHEETROCK. SCALE:1/2'4 ) (4_-) (-) (-) SPEAKER CIRCUIT (+) (+) I (+) „ NOTE FOR ADDITIONAL SPECIF1C&11ONS SEE PRODUCT DOCUMENTATION. (+) TO NEXT APPLIANCE OR 24K (EOLR) (+) TO NEXT SPEAKER ----5 OR END OR LINE RESISTOR 24K (EOLR) (—) SPEAKER CIRCUIT 10 JUNCTION BOX— MOUNTED ON CEILING FLEX / • JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 1 GROUND L 1ODEI TRI -R 0 --)4+)TO NEXT DEVICE OR >(—) STOP IF LAST DEVICE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID —, CEILING DRY CONTACTS TO VAV FAN SHUTDOWN — PROVIDED BY MECHIEIEC. SPEAKER SUPPORT TILE BRIDGE —4" SQUARE DEEP BOX —, / WITH 1-1/2' EXTENSION "\ CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE OTO NEXT DEVICE / 00 CADDY BAR SMOKE DETECTOR JUNCTION BOX MOUNTED ON CEILING FLEX `— SUSPENDED ILLUMINATED CEILING JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 6 00 00 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR -- SMOKE DETECTOR MOUNTING SUSPENDED ILLUMINATED CEILING FA -82 SCALE:NONE STUD SHEET ROCK SPEAKER STROBE OR STROBE ONLY \ \ \ I ‘ i 4S DEEP BOX W/ 1-1/2' EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) F) c0 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z _ DESCRIPTION SHOP DRAWINGS DATE 0 zz., 0, 0 --.. p.) 12 «C« r co 0) co co C) c70 n (Is z ‘CALE: NT DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE:3/09/10 BACKROUND PLAN PROVIDED BY: 11 WALL MOUNTED SPEAKER STROBE FIRE MOUNTING ELEVATIONS .913 NUMBER: SCALE=NONE Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA 02) SYSTEM CALCULATIONS ;Wire Resistance 2.58 0 SET -MC @15CD 0 SET -MC @30CD 2 'SET -MC @75CD 1 Z-MC@15CD 0 ; Z-MC@30CD DEVICES= 3 98 175 64 98 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage 0 350 64 0 414 14 197 19.98 (WL*2)*(R/ft) (Total Cct Load (E=I*R) ;20.4-E) 414 1.02' 0.41; 0.42 19.98! PROJECT: Y SHIEK SHOES Panel: XLS-V (Wire Resistance 2.58 0 2 0 0 DEVICES= 70.7V 1/8 1.8 0 70.7V 1/4 3.6 7.2 70.7V 1/2 7.2 0 70.7V 1 14.4 0 2 TOTAL mA= 7.2 14 240 20.39108352 7.21 Total Wire Resistance (R ) ( WL * 2 ) * (Rift) Total Device Load, Amps (I) (Total Cct Load) Voltage Drop (E ) (E= I * R) EOL Voltage (20.4 - E) 1.24; 0.01 0.014 20.39 : AD1 Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0 0.0022 0.0022 0.0023 0.000 AD2-P 2 0.0635 0.0635 0.064 0.128 HTR -R 0.009600 0.0096 0.021 0.063 HTRI-D 0 0.001600 0 0.0035 0.000 0.0731 Amps 0.191 Amps Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours Alarm Current Load: 0.191 Amps For 15 Minutes 0.048 Amp -hours 25% Derating= 2.253 Amp -hours Total System Current Load: 2.253 Amp -hours Battery Pair to be Used 12VDC Amp -hours 7AH trv'f68 n e t ry L ac C Ilcul bra EXttltt"IS DESCRIPTION SHOP DRAWINGS un Load. c k Y Sl r dby: ` larm: 0 0) 0 M Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC @15CD 0.064 SET -MC @30CD 0.098 SET -MC @75CD 2 0.175 0.350 ZR -MC @15CD 1 0.064 0.064 ZR -MC @30CD 0.098 0.03 Amps 0.444 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.444 Amps For 5 Minutes= 0.037 Amp -hours 25% Derating= 0.947 Amp -hours Total System Current Load: 0.947 Amp -hours ry, .air to be Us d r :' . 1` Vf 2 { .. %{■ i�€i ti -ho 7AH VOLTAGE DROP CALCULATION ATTERY SIZING CALCULATION 1101101 .1010.1.4.00441.6140. MIANS,fnIMMPiMIMMlf.IMWMMMVMMV.Wrvtorr.t. DEDICATED EMERGENCY POWER 120VAC-60HZ cO 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NVI DESCRIPTION SHOP DRAWINGS DATE 0 0) 0 M co oo wco Wz W 0 O �Q0 _ CI)ccz cc w(1) W < w wvg 0 Cr) CU cc cf)w LL w z w z 0 SCALE: NTS DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/09/ 10 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved \0B NUMBER: ,1 % SHEET FA -03 EOL—S1 SCK LFOvE s . b'-': 14V5,4 . �� F�'T i: TE T L ET, ;X22.'..:,"1 =E 1 _v 1 1-16' —12 Lam_ [ a J.544.F TO = — = EE t 'J'40_r▪ 3,.63 Gt: a:J.:N • =D,3=E Tx=C41_ 2S,2V -- 2S,2V S1-3 V1-3 EOL—V •'1.1ti'L R3 CE3C. '-' 64 -ELVES T7 -Jv4 ==L c:., t " 15TGLL=,. 1-1 1.2'.2TC- EL7 AFF • S'_C-GFS-. v` s_C µW SJ F1•' : yI• cF-.: `rLGE3 � NORTH 3:4' 1_4:, T=rR. G-_433 G:3=Lr`" v?J3 SEE G..- .: FG4; . LL cX 5,3?_E 2'X L+ -▪ H • 'LL 4..,,G.3 SET b - 5E.1 -O&& L.:CE` EY. 3T LE34E .:;v..=�; AL.. - Dc3 =�i'lir;.E 1 a'Y tt. ILL Li SHIEK SHOES -F'=' '"-L 453 c=T •.ERT' 1.8- 4'R G4i'5- SCALE 1/8"=1' FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE THESE DEVICES. 4> FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. TENANT FIRE ALARM JUNCTION BOX (FIELD LOCATE) EXISTING CORE AND SHELL FIRE SMOKE DAMPERS RELAY TRIPS TO ACIVATE AND MONITORS PAD 3 TIE TO EXISTING DEVICE TIE TO CLOSES EXISTING SPEAKER STROBE 10 RELOCATE EXISTING DEVICE TIE TO EXISTING EOL REPLACE WITH_15CD SPEAKER STROBE FIELD LOCATE HVAC UNITS SMOKE MUST BE LOCATTED IN THE SAME ROOM AS THE POWER SUPPLY. REFFER TO RISER ON PAGE FA -03 FOR VOICE/SPEAKER WIRING ELECTRICAUINSTALLING CONTRACTOR SHALL RETURN ONE FULL SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved m 7' ti 2 ct D 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS 0 w < o (7)'n 0 M Z 0 CC 0 0 wco e W ;is, LL W Vi W 2coz w JO O � _ 2z �W= W w v� >•- win cf) EE:F E (f)O w cc �CALE: NTS DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/09/10 BACKROUND PLAN PROVIDED BY: `JOB NUMBER: SHEET FA -04 � FULL' G6' SHEET INDEX SHEET NUMBER SHEET TITLE SHIEK SHOES FIRE ALARM SYSTEM TUKWILA, WASHINGTON FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL), RISER FA -04 FIRE ALARM SYSTEM FLOOR PLAN E. 'FE Ir Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire nr,; ention Bureau for conformance with current City ;r;, ndards. Acceptance Is subject to errors and ornisions which do not authorize violations of adopted ;.. r aids and ordinances. The responsibility for the .:C& Uacy of design rests totally with the designer. ;n;i;cions, deletions or revisions to these drawings, after ti -Fs t!?te will void this acceptance and will require a resubrnittai of revised drawings for subsequent approval. ai acceptance is subject to field test and inspection by ne Tukwila Fire Prevention Bureau. _are: ` -1° By: 1...1 I UKWII"A FIRE DEPARTtiltstit Please call: 575.4402 artd give this job No. 10 F-Osti and exact address for shut' Town or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Reinspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1�2" .82 SQUARE INCH 2 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS,- HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND -ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. . 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED SYMBOLS LEGEND QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT 1 3 1 1 2 1 EX FATP FIRE ALARM CONTROL PANEL MXL SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD TRI -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP BOX VERIFY IN FIELD DUCT SMOKE DETECTOR AD2-2P SIEMENS HFP-11 DET DUCT HOUSING VERIFY IN FIELD SMOKE DETECTOR (PHOTOELECTRIC) HFP-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1 G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXT. I FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1 /2" EXT. 80" A.F.F. TO BOTTOM 15 STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM PAM MULTI -VOLTAGE RELAY MODULE PAM -1 AIR PRODUCTS 4S BOX VERIFY IN FIELD FIRE SMOKE DAMPER F.B.O. F.B.❑. N/A VERIFY IN FIELD FATC EX JUNCTI❑N BOX F.B.D. F.B.O. N/A VERIFY IN FIELD Fs WATER FLOW SWITCH F.B.❑. F.B.D. N/A VERIFY IN FIELD O TAMPER SWITCH F.B.D. F.B.O. VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.D. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A MAR 24 2010 Tukwila Fire Copyright 2006 by Guardian Security Systems, Inc. All Ri • hts Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 3/09/10 coo W (r)� z W w Jo co 2z cf) W cc = � Q W Q w� _ ccco -T- EsE = S 0 �CALE: 1 '=1 /8" DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZAN1 DATE: 3/09/10 BACKROUND PLAN PROVIDED BY: JOB NUMBER: SHEET 1 FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCT OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. BEND OR OTHER OBSTRUCTION BEND OR OTHER OBSTRUCTION DUCT DETECTOR- LOCATION TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE 120VAC-60NZ DEDICATED EMERGENCY NNE: FOR ADMIONA. SPE(&1CATIONS SEE PRODUCT DOCUMENTATION. M(YN I E OPTIONS ® SUPERVISORY POINT ® FORM -C- RELAY CONTACTS LED *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC fs7. FkfD,SGi611 rfT TO NEXT ADDRESSABLE -� DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL-(+ OR PREVIOUS ADDRESSABLE - DEVICE JAI CRD N t. =1 no on oo TO THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET—\ SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND 2 TYPICAL MOUNTING FOR AD -2P DUCT DETECTOR BATTERY PAD -3 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX - + - + - + - 1+ 1- 1 2+ 2- 2 NC C NO + - + NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL WIRING FOR HTRI-R MODULE (PAD -3 TRIP) SCALE: NONE FA -02 SCALE:NONE SPEAKE STROBE 'am❑I 11 11 1❑.1b, o/.,.K.1 r .. "-^\ ■ 1 0 1 n 1 \`, t Q- is it I; ;./ A 1 ( li rs` n. 1 0 `1 o a 0 0 ti - .h - 1 ,��\� ,y' .- AeCDEr ON - 4. a ._.I \ mN • _.: ea - 4 ..s ._ 1 �* / j\\ _ FROM PRECEDING STROBE APPLIANCE OR SYNC MODULE (-) NAC -4 e NAC -3 NAC -2 (-) STROBE CIRCUIT SPEAKER CIS ■I 11 Il IULJU 1 - 1 - 1 o1 a. 1 I 1 o ' \`, - / 1 Q- is it I; ;./ A .^ ;mom ( Aecetrot =' > .4113 i. o a 0 0 . AeCetroN .h - ,_ - + oto m -. ,y' ■► i......ijammi❑omp NAC -1 FROM PRECEDING SPEAKER 4( (+) OR FIRE ALARM SPEAKER CONTROL PANEL (FACP) CIRCUIT SPEAKERISTROBE AND STROBE WIRING SCALE:112`=1' 1 1 iI� 1 (+) I (-) (-) (-) TROB IRCUI NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN TEMPERATURE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -- DEVICE 1S USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR •— DB -11 STANDARD SMOKE DETECTOR BASE —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > REAR VIEW (-) HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL > TO NEXT (-) ADDRESSABLE (+) > DEVICE (+) LABEL SCALE STROBE Il❑ 1 1 1 SPEAKERISTROBE ❑ 01 i ❑ 0/- El 1 il:1,2 z Q 1 - DESCRIPTION II, ;I il ;! .^ ;mom ( M .- AeCetroN _ 4. a ._.I \ mN • 1 (-) TROB 1 1 0 7 1 1 0 [ [ \- TA IRCUIIar` 0 SPEAKER CIRCUIT (+) C (-) (+) FOR ADDITIONN. SPECIFICATIONS SEE PRODUCT DOCUMENTATION. I.I! LL? (+) • • (-) (-) JI a n STROBE CIRCUIT (-) FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. m 0 0 0) (+) TSM -1 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPLJFPLR RED (JACKET) 'CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 GENERAL NOTES (-) TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE 1. SPEAKERS ARE TAPPED AT 70.7114 WATT. 2. STROBES CANDELAS ARE ON THE FIELD DRAWINGS. 3, CHECK CUT SHEETS SUPPLIED WITH PARTS BEFORE HOOKING -UP. 4. ALL ALD LOOP WIRES MUST BE IN METAL RACEWAY. S. ANY ALD LOOP WIRE THAT GOES TO FANS 1 DAMPERS THAT ARE PART OF PRESSURIZING OR VENTING SMOKE CONTROL NEED TO BE IN METAL RACEWAY AND 2 -HOUR PROTECTED (CI CABLE OR ENCLOSED IN 2 -HOUR CONCRETE OR SHEETROCK. S TO NEXT APPLIANCE S OR 24K (EOLR) (+)_4 TO NEXT SPEAKER OR END OR LINE RESISTOR (-)24K (EOLR) SPEAKER CIRCUIT JUNCTI❑N BOX---‘ MOUNTED ON CEILING FLEX ry/ ',,/ //z <;/// JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT GROUND . u � � c 0 MODEL: TRI -R 0 0t ; DRY CONTACTS TO VAV FAN SHUTDOWN — PROVIDEDBYMECHIELEC. I -C44 0 —.(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2' EXTENSION \\ CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE:NONE ) per" OTO NEXT DEVICE 0 0 CADDY BAR SMOKE DETECTOR JUNCTION BOX-\ MOUNTED ON CEILING FLEX i -- SUSPENDED ILLUMINATED CEILING 7-'77A), JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 0 0 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING STUD SHEET ROCK SPEAKER STROBE OR — STROBE ONLY 4S DEEP BOX W/ 1-1/2' EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) O CD z (I) LU J uJ (n LC) to (/) (V \O Q I– O — (V re) J w FAX (206) 628-4990 RELEASE/REVISIONS REV. BY: z Q DESCRIPTION SHOP DRAWINGS DATE 0 el 0 M 2 C<QCC z z 0 co W co cf) W 2 (0 2 w Jp O < co2z CO w = � gzQ W Q wUJ 0 's T CC u 1� OD M (U CALE: NTS DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZAN I DATE: 3/09/10 BACKROUND PLAN PROVIDED BY: 11 WALL MOUNTED SPEAKER STROBE FIRE MOUNTING ELEVATIONS UN NUMBER: SCALE:NONE SHEET Copyright 2006 Guardian Security Systems, Inc. All Rights Reserved FA -02 by 9 SYSTEM CALCULATIONS PRO :S ilk ► Panel: XLS-V ;Wire Resistance 2.58 0 SET -MC @15CD 0 SET -MC @30CD 2 SET -MC @75CD 1 Z-MC@15CD 0 Z-MC@30CD DEVICES= 3 64 98 175 64 98 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 0 0 350 64 0 414 14 197 19.98 WL * 2 )* (R/ft) (Total Cct Load) (E=I*R) 20.4 - E) 1 4141 1.02 0.41 0.42 19.98; PROJECT: S IIEK SHO Panel: XLS-V 'Wire Resistance 2.58 p 0 .� � _.. 70.7V 1/8 1.8 0 . _4 .. ___ �_ ._ .._. _ _.,_ _ ,. _W_ s2 SHOP DRAWINGS 2 70.7V 1/4 3.6 7.2 DATE 0 a) 0 0 70.7V 1/2 7.2 0 Total Amps Total 2C<<QQ 0 70.7V 1 14.4. 0 . Main System Board 1 0.03 DEVICES= 2 TOTAL mA= 7.2 14 240 20.39108352 7.21 SET -MC @30CD Q.098 SET -MC ©75CD 2 Total Wire Resistance (R) 0.175 0.350 (WL * 2 )* (R/ft) 1.24; Total Device Load, Amps (I) 0.064 0.064 (Total Cct Load) 0.01 Voltage Drop ( E) (E= I* R) 0.011 0.444 EOL Voltage (20.4 - E) :20.39, Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours P.,ADD ONS, Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total NFP -11 0.0022 0.0022 0.0023 0.002 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 3 0.009600 0.0096 0.021 0.063 HTRI-D 0 0.001600 0 0.0035 0.000 0.0731 Amps 0.127 Amps Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours Alarm Current Load: 0.127 Amps For 15 Minutes 0.032 Amp -hours 25% Derating= 2.233 Amp -hours Total System Current Load: 2.233 Amp -hours Battery Pair to be Used 12VDC Amp -hours 7AH r:i K Kry .� nJ } b � Y i 'K s`J I � ; .�° tyY � 3) q ( " ',.f V ,{,.`"• ePy„{�'d e� T£�M"sry" 1 •Y �, .■(�y'y^.. rL k ' J � Ma: a � ; na Exten er P ne xa e the tions I I DESCRIPTION SHOP DRAWINGS r, Y :r fir'. .. k C renti oa'.d• 3,,, + iYb x''; K+ '" ta' db .'. wII h' k,� A.,. -Alarrrl�. DATE 0 a) 0 Device Type Qty Amps Total Amps Total 2C<<QQ Main System Board 1 0.03 0.03 0.030 0.030 SET -MC ©15C 0.064 SET -MC @30CD Q.098 SET -MC ©75CD 2 0.175 0.350 ZR -MC @15CD 1 0.064 0.064 ZR -MC ©30CD 0.098 0.03 Amps 0.444 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.444 Amps For 5 Minutes= 0.037 Amp -hours 25% Derating= 0.947 Amp -hours Total System Current Load: 0.947 Amp -hours Eat ry' Pair tc► be Used ` p ou VOLTAGE DROP CALCULATION BATTERY SIZING CALCULATION EOL -S S1-3 S1-2 S1-1 V1-2 V V1-1 FIRST FLOOR V - BPS 2C FATC 'EOL -V1 DEDICATED EMERGENCY POWER 120VAC-601Z RISER DIAGRAM 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a I DESCRIPTION SHOP DRAWINGS DATE 0 a) 0 M 2C<<QQ n ‘CALE: NTS DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/09/1 0 BACKROUND PLAN PROVIDED BY: .JOB NUMBER: Co • ri • ht 2006 b Guardian Securit S stems, Inc All Ri • hts Reserved SHEET FA -03 _<t -SCK A_ _ • _;4;: _ 5,577.. `.FJ 5•E` -77-67. X. eG -P4.? t:•• -;•TE. .CT =Ynp5.7.G C --r- •0 rz="Lz: 1-15 1-14 1_=. V L- 70,F 4 3^7•7C+'? E OEE Tr F,C..4.L S1-3 EOL—S1 V1-3 i.j ////Y� I /t EOL—V _1— 45` L1. r ; Z` fL'02 3:3' LA: TE4'P.G-LG.3—' G,S=LAY EEE _ .- I !rF 4; ;,:4i= 5:5" 'l?=E 'X' all. 30 04.3. Ix -0- APS.- =AN -7 'G' ° . NORTH CG5k�R4� _E_ 4,4-1/ 4== :E'.✓'LN G.:S-=0: SHIEK SHOES <=x'' - NER J i'Pi F_=L_ I•.` iF.:�G C tLF GLASS41. c_T 6- 3 .0T :.Ihi BASE 4 1.3= 4 x?. E=:T -,.. ECF -4 _3. .=Y.�•�Y- Lea= AL -0. F,tNELl'3-.;:_44 ALL 4 617:7517)E G_X J1 . L.4 004 TO __s I.3 ..'R 0.P3- a.: SCALE 118":t FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE THESE DEVICES. 4> FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. TENANT FIRE ALARM JUNCTION BOX (FIELD LOCATE) EXISTING CORE AND SHELL FIRE SMOKE DAMPERS RELAY TRIPS TO ACIVATE AND MONITORS PAD 3 E> TIE TO EXISTING DEVICE TIE TO CLOSES EXISTING SPEAKER STROBE 1 - RELOCATE EXISTING DEVICE TIE TO EXISTING EOL REPLACE WITH 15CD SPEAKER STROBE FIELD LOCATE HVAC UNITS SMOKE MUST BE LOCATTED IN THE SAME ROOM AS THE POWER SUPPLY. REFFER TO RISER ON PAGE FA -03 FOR VOICE/SPEAKER WIRING co 0' W y o. 6`t FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 0 rn 0 M 0 0 0 p we W,_ W2 "' Z w JO Qt, w ci) < (1) W_ <C w>" CCs' i w /) �- E (/) o cnn 'Mt, ccw 4CALE: NTS DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/09/ 10 BACKROUND PLAN PROVIDED BY: ELECTRICAUINSTALLING CONTRACTOR SHALL RETURN ONE FULL SET OF ACCURATELY MARKED \OB NUMBER: J DRAWINGS FOR "AS BUILT" PURPOSES. C SHEET FA -04 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved STOCKROOM: CEILING: OPEN TO EXISTING METAL DECK ABOVE a +1V -I0 1/4" A.F.F. 5/5" TYPE 'X' GYP. BD. CURTAN WALL -BOTTOM e +10'-0" AFF.- PAINT (G1) • 0 APPROX. LOCATION OF BLOWER -VERIFY W/ MECN. DWGS. 4 ON SITE L ---J-- k7J APPROX. LOCATION ►- OF BLOWER -VERIFY W/ MECH. DWaS. t ON SITE _J BLOWER e +12'-8" ( — I '1 or I L _I_ J I, a r --I---1 v. v C. 1441 I_ __I _ 'i!i �vV •i. 1 J L_L_ v — r 1 1 L� tzitif N ,(01,/ �JD 4 „p I { i N • FcK(9 r- 1,14 1,1/ t. )tt4r- f; 1 r 1- 1_1 z- I I —I -1 w • 1/44 u 1t t 5/8" TYPE 'X' GYP. BD. CEILING e 13'-0" AFF. PAINT (GI) U DX .o 8 v1 __ . No ' 4 r ' •C_XiC r HANDICAP ACCCESSIBLE TOILE ROOM: CEILING: 5/S" TYPE 'X' GYP. BP. CLG. fa +S'-0" AFF. -PAINT 'G1' SEMI CFL.055 12e-Ezov,1 rtkc. g Lt'A.b4t EQ P-A)I lfS° y202 £'4Wr,/V6 Prn.ail (2...(404.1V 412 • ti et`b(4'i ip.L:rti(r ,t 6'r,Gic 9Q4 TotLe--r 4 t >r� p C:-Gta, M4�rl r' l t1 It 4 la 0,2,0 Ret 17 le NloJeC.: F- ( F",eL..117.5<i1-c f4Q,)C.0 (?' c-- 4-4.0 C S -r ` a Arlt 5/8" TYPE 'X' GYP. BD. CURTAIN WALL -BOTTOM 6 +10'-0" AFF.- PAINT (GI) SALES AREA: CEILING: OPEN TO EXISTING METAL DECK +16'-I0 1/4" AFF. PAINT ALL BEAMS, DUCTING, ETC. OCCURRING ABOVE +12'-5" AFF. (GI) SALES AREA ONLY s`frr-0rtit1) ftsephser 15 t t t ( 47 9.7.• iZ_ rae-Stup qty I. -r,. 5Pe7 I C;e: o r/ -r_ )c SOFFIT/ LEASE LINE 5/8" TYPE 'X' GYP. BD. CEILING e 13'-0" AFF. COVERED WITH .120 THK ALUMINUM PANEL WITH TRANSLUCENT BLUE POWDER COAT FINISH ADHERED TO 5/S" TYPE 'X' GYP. BD.- METAL TO BE BENT ON METAL BRAKE AND THEN PCWPER COATED AND INSTALLED ON GYP. BD. SOFFIT 4 CLG. G.C. TO VERIFr :5UF3 SURFACE IS ABSOLUTELY FLAT PRIOR TO INSTALLATION OF ALUMINUM PANELS. PANELS SHALL HAVE NO DISTORTION 5/8" TYPE 'X. GYP. P. CEILING e 13'-0" AFF. FAINT (GI) 41c/10 r t. ge /Z'/r, aorc4 1-4 pt// NOTE: METAL PANELING TO BE BENT ON METAL BRAKE AND THEN POWDER COATED. AND INSTALLED ON SVP. BD. REFLECTEE) CEILINC : PL4N 1/4" = 1'-0" I s`''HA) nieatflvzv 1-jr1_ztteD ALL 4- titT rLIA- L s ,,,.a L. F; 1L1 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS . 0 Witho ft Comirie lits As Noted in RE: Per The Attached Letter Tis?>e plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City. s.:' ic1ards. Acceptance is subject to errors and ct, is ,'ane which do not authorize violations of adopted :._:7,ndards and ordinances. The responsibility for the . quacy of de -Sign re :s totally with thedesigner. A. d i:ions deletions or revisions to these drawings after • tills dJ ate will void this acceptance and will requires resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by Tne Tukwila Fire Prevention Bureau. Date: � —I (0 By: / J-7 TT3 W1LA FIRE DEPARTIMIX Please call: 575.4402 and give this job No. .�:.. and exact address for shut sown or restoration aiaorov$3t NOTICE Weld stamps must be inspected before pipe is hung. Do nol paint piping prior to hydrostr;tic test approval. EMIR SOUTNCENTERILESWIELD TENANT SPACE '440 984/986 SOWTNCENTER SEATTLE, WASNRJGTON 98188 • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON . 98082-0113 PH. (425) 481-7669 SHIEKH SOUTHCENTER WESTFIELD TENANT SPACE *440 984/ 986 SOUTHCENTER SEATTLE, WASHINGTON 98188 DATE: 3-14,:- .10: I.. DRAWN:..:) A. 1: SCALE: ns i#ef t'AR172010 Tl w al14/ iz---'i e S( j f • o .(/�: 4