Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 990 SOUTHCENTER MALL - LIDS - PERMITS AND PLANS
990 SOUTHCENTER MALL ASSOCIATED PERMITS 17-F-207 17-S-206 08-S-018 /1627121, CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION G! q 0 King Co. Assessor's Tax No20 74114- o b 1 l;7 Site AddresseeCra' C 44 QLk 1LU Nkl V' J Suite Numbed Floor: Tenant Name: L, (AsTh New Tenant? ❑ - Yes Property Owner's Name:6I IP)4 1 e T&IQ' Mailing Address2n € 1 4(4i. i? t ti CONTACT PERSON -if there are questions about the submittal. Name:, Company Name: Mailing Address: I W3 E-mail Address 01 ck City State Zip r� s eve Day Telephone: 2CJLe '(.Q2 -2- ( ZS `ect7f, ZZ� di= UV#61-liSti NICET III number: City State Zip Fax Number: ntractor's City of Tukwila Business License number:' 6°ci2851 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 2 , Scope of Work (please provide detailed information):% re /) jT ecam-) PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY .: Y T AWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMI T. � BUILDING 1 `INER 4' • :�� itsi i ' AGENT: Signatur: t%����Aran Print N. v6r. wJ/i/Lie: / itLJ Plan Permit App.doc 8/22/14 Date: /0/2/1// 4- Day Telephone: `1 D(2 • to Zz -(12616 •27 . TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Lids 990 Southcenter Mall Permit No.: 17-S-206 Date: November 1, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Comply with all three comments on BCE plan review letter dated December 27th 2016. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. QCT pirsl p Without Comments p As Noted in Red r Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City stmiards.• Acceptance is subject to errors and • o,ilisslons which do not authorize violations of adopted t ndards and ordinances. The responsibility for the ;s::!equacy of design rests totally with the designer. .<ditions, deletions or revisions to these drawings after date will void thi , :acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is suo)ect to field test and inspection by The Tukwila Fire Pi evention Bureau. I I Dated -- -1-17 tt By:, TiiICWWIL \ FIRE DEPARTM7NT Pieass c ',:i 206-575-4407 and give this Fife Permit No. - S- a—bso l td N �t�cyc 6 :ddr sss for rPieas • i . wn e s �.�'.��s f"w o L' tii on app 1..o V ale 60'-5 7/8" LEASE LINE RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAt4/ C—CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JD/ST/TRUSS HANGER DETAIL NTS FlexHead Sprinkler Drop . 1,111111111bN4. stIkk FLXIF. • INDI15, p,ES • Mulf-Port Bracket • • Corrugated stainless steel hose with stainless sleet bre available In 2', 3'4',5' & 6' legriths . • Adjustable Hub • • Flexhead omme'reial Ceiling Unit T -Bar Ceiling Installation Model #2024,2036,2048,060,2072 • • • • • • • SOFFIT GYP. BD. 8"-2"-A.F.F. MALL CORRIDOR w®eeeeesesenee NOY ADJACENT TENANT Design per NFPA 13 — Ordinary Hazard Group 2 (Retail) All Materials to be new, U. L:. listed and F: M. approved All heads to be at least 6' apart with no obstructions +SPRINKLER PLAN SCALE:. 1/4"=1'-0" o 5 — Add Reliable Model G5-56 Quick Response 165° Concealed PendentsY2 x 1/2 - White o 8 — Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x'/2 - White ;0%1 o 4 — Relocate existing pendents to Globe Model GL5615 Quick Response 155° Brass Uprights 1/2 x 1/2 ,100 .SOFFIT .. GYP. BD. 10'-0" AFF John J: Abel • Crown t tri, CROWNFP0441L . • r ask er UX4111 1SS MIL FIRE. PROTECTION: INCQRPORATED :Ra BOX 12113:.:. MILL CREEK, WASHINGTON 98082-0113:. pH. 025) 481-7669 -0`; • WESTFIELD MALL 990 Southcenter Malt, • Space '.446. Tukwila, WA 981:88 SCALE: 40.10S% 1171 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review: **PLEASE PRINT** King Co. Assessor's Tax No.: SITE LOCATION CITY OF TUKWH A FIRE MARSHAL'S O}FICE 206-575-4407 Site Address: 10 s(.0 tw\ \ Suite Number: A (o Floor. Tenant Name:L �`t� (� New Tenant? j - Yes J - No W Property Owner's Name: e5 'C 1 32. \ t� Mailing Address: -1-1OS O `& Gr Ct.c-c CC r skt©kt 'Q- , EL c.ddfl 5 .14e. (oo City State Zip CONTACT PERSON -if there are questions about the submittal Name: e 5) \ CA \ n S 0 (-Ii Day Telephone: (—VZS--i t 1 �P 9 Company Name: (OL,) (t Ft k t. ` r O - -e C \ Mailing Address: ft's 6 0 . `21\3 t r 1 , \\ c1 ec+`oe- pt T6QT �• rCity �/ rip E-mail Address: �t?Ss 11 x A. C G t"U � n C -to, C tY1; Fax Number —I 41,5"*" 8 /- '& qS Contractor's City of Tukwila NICET III number: Business License number. Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 3,000 Scope of Work (please provide detailed information): A I G1 ‘ J e. j c Q\ot. 0,\-e. \ PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days ager its issuance, or ifthe work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: V� c C 41 c-� SSC e_ 4i^!\ O3 W C� Plan Permit App.doe 827/14 Date: toJi-iJ ,i Day Telephone: 1425 - Lk V-1(0 C 41 1FD FP Form 8 1 7—S— -(9c, Bulletin 034 Rev. C ModelG5-80, Model G5-56, Reliabit Model G5-42, Model G5-28 Quick Response Concealed Automatic Sprinkler UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4" (19mm) Adjustment Features , 1. Cover plate attachment (Plain or Perforated) with 3/a" (19mm) assembly adjustment. 2. Smooth aesthetic ceiling profile. 3. Factory installed protective cap. 4. Available in Chrome and White as Standard Finish- es. Special Application Finishes are also available. 5. Ordinary and Intermediate temperature rating. For additional Sprinklers refer to Bulletin 154 for Technical Specification and Approvals Approvals & Listings 1. Underwriters Laboratories Inc. and cULus - Quick Response • G5-80, G5-56 - Light Hazard and Ordinary Hazard Occupancies • G5-42 - Light Hazard Occupancies • G5-28 - Light Hazard Occupancies 2. Factory Mutual Research Corp. (FM) - Standard Response (See Page 3) • See the most recent FM Global Property Loss Prevention Data Sheets for installation and use guidelines. 3. Loss Prevention Council (LPCB, UK) - Standard Response • G5-56 - Light Hazard and Ordinary Hazard Occupancies 4. VdS Schadenverhi.itung GmbH - Standard Response 5. EC -Certificate of Conformity 0832 -CPD -2062 U.S. Patent number 6,554,077. Application The Reliable Model G5-80, G5-56, G5-42 and G5-28 are the most versatile quick response concealed sprinklers avail- able. It provides the best form of fire protection while offering an attractive appearance and 3/4" (19mm) of cover adjust- ment for ease of installation. The small diameter cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an au- tomatic sprinkler system. Plain Cover Plate Perforated Cover Plate The Model G5-80, G5-56, G5-42 and G5-28 are designed for use where aesthetic appearance is important. Offices, hos- pitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13. FM Approves the G5-56 and the G5-28 sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. Product Description The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides 3/4" (19mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 0 •nab{ 17£0 u!3alln8 Installation Do not install the G5-80, G5-56, G5-42 and G5-28 in ceilings which have positive pressure in the space above. • Cut a 25/" inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/ CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G5-80, G5-56, G5-42 and G5-28 should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. Concealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. 2. Ordering Information 1. Sprinkler Model 2. Nominal Orifice 3. Flat Cover Plate Plain or Perforated 4. Flat Cover Plate Assembly Finish 5. Inlet Type Cover Plate Finishesto Standard Finishes Chrome White Paint Special Application Finishes' Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi -gloss, unless specified otherwise. For the perforated style cover - plate, consult factory for avail- ability on these and other cus- tom finishes. Model FC Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Maximum Working Pressure -75 psi (12 bar) '00% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating Classification Sprinkler Cover Plate Max. Ambient Temp. Ordinary 165°F/74°C 135°F/57°C 100°F/38°C Intermediate 212°F/100°C 165°F/74°C 150°F/66°C Technical Data Sprinkler ModelIdentification Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor Thread Approvals Sprinkler (SIN) US Metric G5-80 Non Adjustable 3A" (19mm) 17/32" (15mm) 8.0 115 3A" NPT (R3A) 1 RA3412 G5-56 Non Adjustable 3/4" (19mm) 1/2" (15mm) 5.6 80 1/2" NPT (R1/2) 1,2,3,4,5 RA3415 G5-42 Non Adjustable 3/4" (19mm) '/,e" (10mm) 4.2 60 1/2" NPT (R'/2) 1 RA3413 G5-28 Non Adjustable 3/4" (19mm) 3/a" (10mm) 2.8 40 1/2" NPT (R'h) 1,2 RA3411 For VdS Approval, temperature rating sprinkler 165°F/74°c and cover plate 135°F/57°C only! 1" x 1/2" REDUCING TEE OR ELBOW - Ill__ in III 21A" [58.42mm] DIA CUP r � . 1" x 3/4" REDUCING TEE OR ELBOW G5-80 ONLY to i jll r--, I 4- [65.55mm] HOLE IN CEILING CEILING 1 A 1 2-1/4" [50.8mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION i i" [19.05mm] MAX. J COVER ADJUSTMENT FLAT COVER PLATE ASSEMBLY O34FGO IA SPRINKLER 311" [84.21mm] DIA. " [4.96mm] —t COVER PLATE: 3/4" [19.O5mm) ADJUSTMENT Notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS 1' x 1/2' REDUCING 7F£ OR ELBOW � --�--_ Il I Til - 1L jlt RELIABLE P/N 6999991900 I" X 1i" BRASS NIPPLE EXT. 2,1" [58.42mm] DIA CUP i" (19.05mm] MAX. COVER ADJUSTMENT 03RL172 COLING FLAT COVER PLATE ASSEMBLY 3-1/16" [77.72mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 2-1/4" [50.8mm] M4X. FACE OF NIPPLE EXT. TO FACE OF COLING DIMENSION SPRINKLER W3" [84.21mm] DM " [4.96mm] COVER PLATE: 3/4" [19.05mm] ADJUSTMENT NOTE: 1. Testing has shown that use of a "nipple extension" will not affect the listing of the sprinkler. 2. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, "which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems". 3. Do not exceed 8-18 ft -lbs of torque during installation. 3. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of govemmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly quallfied and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by ReIiabi The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/13 P/N 9999970421 Design per NFPA 13, Ordinary Hazard, 130 Sq. Feet Max All materials to be riew, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart • 12 — Add Reliable Model F1 Standard Response 155° Pendants 1/2 x 1/2 NEW MGR AND CRS EL 11-0' A.F.F. 2-6 FIEW CLCJ1 AND GRID EL 11-0' A.F.F. I lA SPKR w I®L G G Di 3PKR zji Fire Ccsr3 Plan I's /y 0 Without Comments As Noted In Red Per The Attached Letter i nese plans have beer: , Prevention Bureau -.c.' .A_ standards. Acce :a31... . omissions wi aic,. ::. ; ]:. standards and adequacy of 6 Additions, delet: ,,...,...,.i..1„..,..: r::, i:r,ese drawings atter this date will VC.'sid tfiij.aCC�N ;nCe and will require a resubmittal of revised drawings for subsequent approval. h Final acceptance is subject to; field test and inspection by The Tukwila Fire Prevention Bureau.n_ !Date: /' ° ' 0.S? By: / 1 1 .(1 1 Fire rpt city r;cfi: of adopted r slr�ility for the designer. IN EAINER TAREA S HERE REQUIRED I1TET SdM SET are' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS 1 IUKWILA FIRE DEPARTMEN1 Please call: 575.4402 and give this job No. OB -S- OI 2 and exact address for shut. i Sown or restoration approv l Dzcauee of increased demand ow' ink:. tors°edules are booked 3-7 clays ahele 4. Therefore, you will need to call 206-5754407 or email ri�rein gstt d.tukWiia.wa,us to schedule your inspections a minimum of 43 hours in advance of the date you want an inspection. FILE COPY CROWN FIRE PROOF C ►ICN INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 LIDS LD5102 WESTFIELD. SOUTHCENT �:63'3-50UTHCENTER ,������.�'' , SPACE .# 446 DATE: i i 1 q I D71 DRAWN: (,4 I SCALE: i/ AP1 of 1_ J:-.:1 J 2 ?. 2008 Tukwila Fire IR STORE #5102 ALARM SYSTEM ' DDITI N TUKWILA, WASHINGTON SH SET \ U V1BESHEET TITLE FA -01 SYSTEIV \FOMATION FA -02 TYPICAL WHI\G A\3 VOU\ TING DETAILS FA -03 SYSTE v CALCULATIO\S A\D SI\GLE LI\E DIAG A1v FA -0 FRE ALA v SYSTE v PLA\ SHEET INDEX MW Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rest totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection b.., The Tukwila Hre Prevention Bureau. Date: 1 / -a`" / 7 By: TUKWILA FIRE- DEPARTM,NT Please call 206-575-4407 and give this Fire Permit No. and each address for shut- down hutdown or mtonzton approva RULE A\ 3 CO\DUIT FILL_ CHAT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 G.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HAN,ERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, SHEETS AND/OR INSTALLATION INSTRUCTIONS. SET OF ACCURATELY MARKED REFER TO CATALOG CUT 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES ANC JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUC-ORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 2 1 2 1 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY E (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 3 FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELL TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N /A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N /A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LL.EL3 LiDS STORE #5102 SPACE #446 mads r li L • I......,a • :,..,,;. L.. o ri SUMS "'L . Jaz---•i�t�-�:-c =In PAID TUKWILA FRE F:,, ;ney WIRE DESIGNATION GENERAL NOTES SITE PLAN CC� t i J 0 D J) RELEASE/REVISIONS CO w 0 DESCRIPTION SHOP DRAWINGS w 0 N 0 0 • 2 (0 CV z w co O0Uo;o Q0) C) C) Q _JE- W w z 0 < I-- z CO w W~ fr- .....I1.1 (n i - CD 0 CO N SCALE: NOT TO SOLE DRAWN BY: D. GARCIA DESIGNED BY: . T. QUAALE DATE: 10/ a : 7 BACKROUND PLAN PROVIDED BY: \ 0B NUMBER:26455- N SHEET Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved FA -OI THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ DEDICATED EIAERGENCY TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE FOR ADDITIONAL SPEORCATIONS SEE PRODUCT DOCUuINTA110N. *CONTACT RATINGS: 4.0A 0 125VAC 4.OA 0 30VDC COMB p�� SHIELDS AND ISOLA FROM GROUNDING TO NEXT ADDRESSABLE (I - DEVICE + DEVICE STOP If LAST DEVICE FROM XLS CONTROL PANEL(+ OR PREVIDUS ADDRESSABLE DEVICE O } GROUZ-1 L J HTRI-R .D7 O ° O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C—CABLE C—CABLE I GRD N L O PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ - 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 (+) NAC 3CIRCUIT NAC 2 CIRCUIT CEILIN TILE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (-) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE 0 (+) FROM XLS CONTROL PANEL OR —(+ PREVI❑US ADDRESSABLE DEVICE END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH 1 01 GROUND 0 0 0 LO ©° HTRI-R STAT1S LED CO 0 N.O. 0 COM CD 0 N.C. 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. MUSIC HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL L AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERA9TIN TEMPERATURE: +32'F (0' C TO 100' F (36 C) }TUMIDITY: bbbb-939 RELATIVE HUMIDITY, NON—CONDENSING HFP-11 SMOKE DETECTOR TO NEXT DEVICE OR END OF LINE DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CON,UNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (—) > DATA IN (+) > REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL > TO NEXT > ADDRESSABLE DEVICE FROM PREVIOUS , ADDRESSABLE DEVICE TBI NO COM NC EOLR yV. 470 0 0 SWITCH + - INPUT LED TSM -1 00 0 TO FAN SHUTDOWN 0 e TO NEXT ADDRESSABLE DEVICE /7n O NO 8 COM B HTRI-R "C® °/L TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTI❑N BOX---\ MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 00 0 0 ca TO NEXT DEVICE -CADDY BAR HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL .-1m / SMOKE DETECTOR TYPICAL WIRING AND MOUNTING DETAILS SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved -J r)CO (�\ O` J ▪ o r- D (n `< Li_ L.LI ._I LJJ (_) - -J jl f) - 1— (n cv yr) L. RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE N 0i 0 til 0 C9 z 0 0 z 0 z aa§ EF CALE: NOT TO SCAL� DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/1 9/ 17 BACKROUND PLAN PROVIDED BY: \OB NUMBER::"%6455-1_, r SHEET FA -02 A B C D E F G H J K FIRE ALARM BOOSTER Project: LIDS STORE #5102 WSCM Panel: EXISTING PAD -3 REMOTE Date: October 19, 2017 Module/Device POWER T.I. BOOSTER Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm. (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 ZH-MC-CW @30cd 131 Notification Appliance Load (Max. Total / mA) 0 3287 0 Total(A)= 15 Total(B)= 3427 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 3427 Total current ratings converted to amperes (line D x .001) 0.015 3.427 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH ZR -MC -CW @15cd 69 0.2854691 Add lines G and I Total Standby and Alarm AH 0.6454691 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.77456292 ZR -MC -CW @30cd 111 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: LIDS STORE #5102 WSCM T.I. Panel: EXISTING PAD -3 REMOTE POWER SUPPLY Wire Resistance 2.58 October 19, 2017 CURRENT TOTAL- 3287.00 jDate: � I a4 f t :"J z}�i i , es p p' TAT , 7l ' , ,{.;. JSA? i {FB r;`n , � t i" ,. i'x �' - ? f 1" f }L � j !q y. 4 P; b .. 'fit"! q ;`ol Y. 1 al -MC -CW @15cd 87 87 DATE � rn 1 ZH-MC-CW @30cd 131 131 0 ZH-MC-CW @75cd 222 0 7.H -MC -CW @95cd 292 0 1 ZR -MC -CW @15cd 69 69 ZR -MC -CW @30cd 111 0 DEVICES 3 TOTAL mA= 287 14 319 23.53 287 Total Wire Resistance (R) (WL * 2 )* (R/ft) 1.65 Total Device Load, Amps (1) (Tota_ l Cct Load) 0.29 Voltage Drop ( E) (E= I * R) 0.47 EOL Volflt'age - 24 - E) 23.53 tib Y' _ }, m"r,��# Y.. �U ~ `„, - '..}t;�3 int'- t i t. t? s �,. vt v, i 1 aen # tl n ii.!'', [- -{r Ems, � , jt A)Y ,( �ti 6�' f;i,'¢4..: t '�%'6A ? `'9^: $ �. .i aiJ r . . -�'.._._.�_.....,.,.�{,^§ 4 ...,. ...• DEVICES MAXIMUM LOAD TOTAL mA= 1500 14 .,...>,........,,......„.,...; �.._... .v..y.,....x..,..»f. _.......... 24.00 1500 Total Wire Resistance (R) (WL * 2 ) * (Rift) 0.00 Total Device Load, Amps (1) (Total Cct Load) 1.50 Voltage Drop (E) (E= 1* R) 0.00 EOL Voltage 24 - E) 24.00 i:'�3•��� � £ .3'r t,�,: .. . a� ��. `j B. 't31(j^-bN...7}%ke�i°.: it. ,.', ,I)l - Ir' tyT t!P. jf �. 5:3, '. b•f ,e'�• .. ....1Y `�+f �,.TI ;'?���, '�'Y gi e: �tf - i } i�•",., ., -yw,.„ i��s� s��=�+�� f., F'n' d3?'.+t u1 -i i`1 ,.: i.,� �._. {ll36���i , i. x' f� ., DEVICES MAXIMUM LOAD TOTAL mA= 1500 14 24.00 1500 Total Wire Resistance (R) • (WL * 2 )* (Rift) 0.00 Total Device Load, Amps (1) (Total Cct Load) 1.50 Voltage Drop ( E) (E= 1* R) 0.00 EOL Voltage 24 - E) 24.00 CALCULATIONS IDS STO FACP Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps D,I 1 S3-1 15Cd HT -R 21 TSM S3-2 30Cd SINGLE LINE DIAGRAM S3-3 15Cd EOL S3 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. WASHINGTON 1J RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE � rn 0 o IZwo °Uc o u)© I I LL O�UJQ Ci w U Q o w J E On - 0 co N TONS & SINGLE LINE DIAGRA SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/19/i 7 BACKROUND PLAN PROVIDED BY: �0B NUMBER: 2545fill} SHEET FA -03 Proprietary and Confidential, Coeyright 2013 by Guardian Security Systems, Inc. All Rights Reserved TO EXISTING TENANT JUNCTION BOX 101 t.TOCKROOM H - OPE 16'-6" .EF. S3-1 60-57/8" LEASE UNE ] • SOFFIT — , :GYP. BD: 8"-1" A.F.F. SOFFIT ,GYP. BD. 8"-2" A.F.F. I [ADJACENT TENANT 100 SALES AREA ACT -01 111 –0" A.F.F. • I - I 100 r SALES AREA 1ACT-01BI 10'4' A.F.F. 100 SALES AREA t.IILLVIORK FIXTly-113/4" A.F.F. ADJACENT TENANT 9 S3-JII 3 15Cd FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 100 SOFFIT GYP. BD. 12'– 101/2 AFF 100 SOFFIT :GYP. BD. 10'-0" AFF (ix MALLCONCOURSE ; C", F.t) Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 11 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION I SHOP DRAWINGS DATE N 0, 0 (0 co w co O co < -0 CC w W < 1- 0 — o (1) 1- 0 co CALE: /4"= '0'" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:10/19/ 7 BACKROUND PLAN PROVIDED BY J0E3 NUMBER:26455-1} I SHEET FA -04 990 SOUTHCENTER MALL ASSOCIATED PERMITS 17-F-207 17-S-206 08-S-018 /1627121, CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION G! q 0 King Co. Assessor's Tax No20 74114- o b 1 l;7 Site AddresseeCra' C 44 QLk 1LU Nkl V' J Suite Numbed Floor: Tenant Name: L, (AsTh New Tenant? ❑ - Yes Property Owner's Name:6I IP)4 1 e T&IQ' Mailing Address2n € 1 4(4i. i? t ti CONTACT PERSON -if there are questions about the submittal. Name:, Company Name: Mailing Address: I W3 E-mail Address 01 ck City State Zip r� s eve Day Telephone: 2CJLe '(.Q2 -2- ( ZS `ect7f, ZZ� di= UV#61-liSti NICET III number: City State Zip Fax Number: ntractor's City of Tukwila Business License number:' 6°ci2851 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 2 , Scope of Work (please provide detailed information):% re /) jT ecam-) PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY .: Y T AWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMI T. � BUILDING 1 `INER 4' • :�� itsi i ' AGENT: Signatur: t%����Aran Print N. v6r. wJ/i/Lie: / itLJ Plan Permit App.doc 8/22/14 Date: /0/2/1// 4- Day Telephone: `1 D(2 • to Zz -(12616 •27 . TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Lids 990 Southcenter Mall Permit No.: 17-S-206 Date: November 1, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Comply with all three comments on BCE plan review letter dated December 27th 2016. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. QCT pirsl p Without Comments p As Noted in Red r Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City stmiards.• Acceptance is subject to errors and • o,ilisslons which do not authorize violations of adopted t ndards and ordinances. The responsibility for the ;s::!equacy of design rests totally with the designer. .<ditions, deletions or revisions to these drawings after date will void thi , :acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is suo)ect to field test and inspection by The Tukwila Fire Pi evention Bureau. I I Dated -- -1-17 tt By:, TiiICWWIL \ FIRE DEPARTM7NT Pieass c ',:i 206-575-4407 and give this Fife Permit No. - S- a—bso l td N �t�cyc 6 :ddr sss for rPieas • i . wn e s �.�'.��s f"w o L' tii on app 1..o V ale 60'-5 7/8" LEASE LINE RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAt4/ C—CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JD/ST/TRUSS HANGER DETAIL NTS FlexHead Sprinkler Drop . 1,111111111bN4. stIkk FLXIF. • INDI15, p,ES • Mulf-Port Bracket • • Corrugated stainless steel hose with stainless sleet bre available In 2', 3'4',5' & 6' legriths . • Adjustable Hub • • Flexhead omme'reial Ceiling Unit T -Bar Ceiling Installation Model #2024,2036,2048,060,2072 • • • • • • • SOFFIT GYP. BD. 8"-2"-A.F.F. MALL CORRIDOR w®eeeeesesenee NOY ADJACENT TENANT Design per NFPA 13 — Ordinary Hazard Group 2 (Retail) All Materials to be new, U. L:. listed and F: M. approved All heads to be at least 6' apart with no obstructions +SPRINKLER PLAN SCALE:. 1/4"=1'-0" o 5 — Add Reliable Model G5-56 Quick Response 165° Concealed PendentsY2 x 1/2 - White o 8 — Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x'/2 - White ;0%1 o 4 — Relocate existing pendents to Globe Model GL5615 Quick Response 155° Brass Uprights 1/2 x 1/2 ,100 .SOFFIT .. GYP. BD. 10'-0" AFF John J: Abel • Crown t tri, CROWNFP0441L . • r ask er UX4111 1SS MIL FIRE. PROTECTION: INCQRPORATED :Ra BOX 12113:.:. MILL CREEK, WASHINGTON 98082-0113:. pH. 025) 481-7669 -0`; • WESTFIELD MALL 990 Southcenter Malt, • Space '.446. Tukwila, WA 981:88 SCALE: 40.10S% 1171 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review: **PLEASE PRINT** King Co. Assessor's Tax No.: SITE LOCATION CITY OF TUKWH A FIRE MARSHAL'S O}FICE 206-575-4407 Site Address: 10 s(.0 tw\ \ Suite Number: A (o Floor. Tenant Name:L �`t� (� New Tenant? j - Yes J - No W Property Owner's Name: e5 'C 1 32. \ t� Mailing Address: -1-1OS O `& Gr Ct.c-c CC r skt©kt 'Q- , EL c.ddfl 5 .14e. (oo City State Zip CONTACT PERSON -if there are questions about the submittal Name: e 5) \ CA \ n S 0 (-Ii Day Telephone: (—VZS--i t 1 �P 9 Company Name: (OL,) (t Ft k t. ` r O - -e C \ Mailing Address: ft's 6 0 . `21\3 t r 1 , \\ c1 ec+`oe- pt T6QT �• rCity �/ rip E-mail Address: �t?Ss 11 x A. C G t"U � n C -to, C tY1; Fax Number —I 41,5"*" 8 /- '& qS Contractor's City of Tukwila NICET III number: Business License number. Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 3,000 Scope of Work (please provide detailed information): A I G1 ‘ J e. j c Q\ot. 0,\-e. \ PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days ager its issuance, or ifthe work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: V� c C 41 c-� SSC e_ 4i^!\ O3 W C� Plan Permit App.doe 827/14 Date: toJi-iJ ,i Day Telephone: 1425 - Lk V-1(0 C 41 1FD FP Form 8 1 7—S— -(9c, Bulletin 034 Rev. C ModelG5-80, Model G5-56, Reliabit Model G5-42, Model G5-28 Quick Response Concealed Automatic Sprinkler UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4" (19mm) Adjustment Features , 1. Cover plate attachment (Plain or Perforated) with 3/a" (19mm) assembly adjustment. 2. Smooth aesthetic ceiling profile. 3. Factory installed protective cap. 4. Available in Chrome and White as Standard Finish- es. Special Application Finishes are also available. 5. Ordinary and Intermediate temperature rating. For additional Sprinklers refer to Bulletin 154 for Technical Specification and Approvals Approvals & Listings 1. Underwriters Laboratories Inc. and cULus - Quick Response • G5-80, G5-56 - Light Hazard and Ordinary Hazard Occupancies • G5-42 - Light Hazard Occupancies • G5-28 - Light Hazard Occupancies 2. Factory Mutual Research Corp. (FM) - Standard Response (See Page 3) • See the most recent FM Global Property Loss Prevention Data Sheets for installation and use guidelines. 3. Loss Prevention Council (LPCB, UK) - Standard Response • G5-56 - Light Hazard and Ordinary Hazard Occupancies 4. VdS Schadenverhi.itung GmbH - Standard Response 5. EC -Certificate of Conformity 0832 -CPD -2062 U.S. Patent number 6,554,077. Application The Reliable Model G5-80, G5-56, G5-42 and G5-28 are the most versatile quick response concealed sprinklers avail- able. It provides the best form of fire protection while offering an attractive appearance and 3/4" (19mm) of cover adjust- ment for ease of installation. The small diameter cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an au- tomatic sprinkler system. Plain Cover Plate Perforated Cover Plate The Model G5-80, G5-56, G5-42 and G5-28 are designed for use where aesthetic appearance is important. Offices, hos- pitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13. FM Approves the G5-56 and the G5-28 sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. Product Description The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides 3/4" (19mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 0 •nab{ 17£0 u!3alln8 Installation Do not install the G5-80, G5-56, G5-42 and G5-28 in ceilings which have positive pressure in the space above. • Cut a 25/" inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/ CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G5-80, G5-56, G5-42 and G5-28 should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. Concealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. 2. Ordering Information 1. Sprinkler Model 2. Nominal Orifice 3. Flat Cover Plate Plain or Perforated 4. Flat Cover Plate Assembly Finish 5. Inlet Type Cover Plate Finishesto Standard Finishes Chrome White Paint Special Application Finishes' Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi -gloss, unless specified otherwise. For the perforated style cover - plate, consult factory for avail- ability on these and other cus- tom finishes. Model FC Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Maximum Working Pressure -75 psi (12 bar) '00% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating Classification Sprinkler Cover Plate Max. Ambient Temp. Ordinary 165°F/74°C 135°F/57°C 100°F/38°C Intermediate 212°F/100°C 165°F/74°C 150°F/66°C Technical Data Sprinkler ModelIdentification Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor Thread Approvals Sprinkler (SIN) US Metric G5-80 Non Adjustable 3A" (19mm) 17/32" (15mm) 8.0 115 3A" NPT (R3A) 1 RA3412 G5-56 Non Adjustable 3/4" (19mm) 1/2" (15mm) 5.6 80 1/2" NPT (R1/2) 1,2,3,4,5 RA3415 G5-42 Non Adjustable 3/4" (19mm) '/,e" (10mm) 4.2 60 1/2" NPT (R'/2) 1 RA3413 G5-28 Non Adjustable 3/4" (19mm) 3/a" (10mm) 2.8 40 1/2" NPT (R'h) 1,2 RA3411 For VdS Approval, temperature rating sprinkler 165°F/74°c and cover plate 135°F/57°C only! 1" x 1/2" REDUCING TEE OR ELBOW - Ill__ in III 21A" [58.42mm] DIA CUP r � . 1" x 3/4" REDUCING TEE OR ELBOW G5-80 ONLY to i jll r--, I 4- [65.55mm] HOLE IN CEILING CEILING 1 A 1 2-1/4" [50.8mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION i i" [19.05mm] MAX. J COVER ADJUSTMENT FLAT COVER PLATE ASSEMBLY O34FGO IA SPRINKLER 311" [84.21mm] DIA. " [4.96mm] —t COVER PLATE: 3/4" [19.O5mm) ADJUSTMENT Notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS 1' x 1/2' REDUCING 7F£ OR ELBOW � --�--_ Il I Til - 1L jlt RELIABLE P/N 6999991900 I" X 1i" BRASS NIPPLE EXT. 2,1" [58.42mm] DIA CUP i" (19.05mm] MAX. COVER ADJUSTMENT 03RL172 COLING FLAT COVER PLATE ASSEMBLY 3-1/16" [77.72mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 2-1/4" [50.8mm] M4X. FACE OF NIPPLE EXT. TO FACE OF COLING DIMENSION SPRINKLER W3" [84.21mm] DM " [4.96mm] COVER PLATE: 3/4" [19.05mm] ADJUSTMENT NOTE: 1. Testing has shown that use of a "nipple extension" will not affect the listing of the sprinkler. 2. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, "which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems". 3. Do not exceed 8-18 ft -lbs of torque during installation. 3. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of govemmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly quallfied and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by ReIiabi The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/13 P/N 9999970421 Design per NFPA 13, Ordinary Hazard, 130 Sq. Feet Max All materials to be riew, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart • 12 — Add Reliable Model F1 Standard Response 155° Pendants 1/2 x 1/2 NEW MGR AND CRS EL 11-0' A.F.F. 2-6 FIEW CLCJ1 AND GRID EL 11-0' A.F.F. I lA SPKR w I®L G G Di 3PKR zji Fire Ccsr3 Plan I's /y 0 Without Comments As Noted In Red Per The Attached Letter i nese plans have beer: , Prevention Bureau -.c.' .A_ standards. Acce :a31... . omissions wi aic,. ::. ; ]:. standards and adequacy of 6 Additions, delet: ,,...,...,.i..1„..,..: r::, i:r,ese drawings atter this date will VC.'sid tfiij.aCC�N ;nCe and will require a resubmittal of revised drawings for subsequent approval. h Final acceptance is subject to; field test and inspection by The Tukwila Fire Prevention Bureau.n_ !Date: /' ° ' 0.S? By: / 1 1 .(1 1 Fire rpt city r;cfi: of adopted r slr�ility for the designer. IN EAINER TAREA S HERE REQUIRED I1TET SdM SET are' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS 1 IUKWILA FIRE DEPARTMEN1 Please call: 575.4402 and give this job No. OB -S- OI 2 and exact address for shut. i Sown or restoration approv l Dzcauee of increased demand ow' ink:. tors°edules are booked 3-7 clays ahele 4. Therefore, you will need to call 206-5754407 or email ri�rein gstt d.tukWiia.wa,us to schedule your inspections a minimum of 43 hours in advance of the date you want an inspection. FILE COPY CROWN FIRE PROOF C ►ICN INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 LIDS LD5102 WESTFIELD. SOUTHCENT �:63'3-50UTHCENTER ,������.�'' , SPACE .# 446 DATE: i i 1 q I D71 DRAWN: (,4 I SCALE: i/ AP1 of 1_ J:-.:1 J 2 ?. 2008 Tukwila Fire IR STORE #5102 ALARM SYSTEM ' DDITI N TUKWILA, WASHINGTON SH SET \ U V1BESHEET TITLE FA -01 SYSTEIV \FOMATION FA -02 TYPICAL WHI\G A\3 VOU\ TING DETAILS FA -03 SYSTE v CALCULATIO\S A\D SI\GLE LI\E DIAG A1v FA -0 FRE ALA v SYSTE v PLA\ SHEET INDEX MW Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rest totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection b.., The Tukwila Hre Prevention Bureau. Date: 1 / -a`" / 7 By: TUKWILA FIRE- DEPARTM,NT Please call 206-575-4407 and give this Fire Permit No. and each address for shut- down hutdown or mtonzton approva RULE A\ 3 CO\DUIT FILL_ CHAT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 G.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HAN,ERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, SHEETS AND/OR INSTALLATION INSTRUCTIONS. SET OF ACCURATELY MARKED REFER TO CATALOG CUT 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES ANC JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUC-ORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 2 1 2 1 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY E (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 3 FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELL TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N /A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N /A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LL.EL3 LiDS STORE #5102 SPACE #446 mads r li L • I......,a • :,..,,;. L.. o ri SUMS "'L . Jaz---•i�t�-�:-c =In PAID TUKWILA FRE F:,, ;ney WIRE DESIGNATION GENERAL NOTES SITE PLAN CC� t i J 0 D J) RELEASE/REVISIONS CO w 0 DESCRIPTION SHOP DRAWINGS w 0 N 0 0 • 2 (0 CV z w co O0Uo;o Q0) C) C) Q _JE- W w z 0 < I-- z CO w W~ fr- .....I1.1 (n i - CD 0 CO N SCALE: NOT TO SOLE DRAWN BY: D. GARCIA DESIGNED BY: . T. QUAALE DATE: 10/ a : 7 BACKROUND PLAN PROVIDED BY: \ 0B NUMBER:26455- N SHEET Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved FA -OI THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ DEDICATED EIAERGENCY TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE FOR ADDITIONAL SPEORCATIONS SEE PRODUCT DOCUuINTA110N. *CONTACT RATINGS: 4.0A 0 125VAC 4.OA 0 30VDC COMB p�� SHIELDS AND ISOLA FROM GROUNDING TO NEXT ADDRESSABLE (I - DEVICE + DEVICE STOP If LAST DEVICE FROM XLS CONTROL PANEL(+ OR PREVIDUS ADDRESSABLE DEVICE O } GROUZ-1 L J HTRI-R .D7 O ° O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C—CABLE C—CABLE I GRD N L O PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ - 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 (+) NAC 3CIRCUIT NAC 2 CIRCUIT CEILIN TILE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (-) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE 0 (+) FROM XLS CONTROL PANEL OR —(+ PREVI❑US ADDRESSABLE DEVICE END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH 1 01 GROUND 0 0 0 LO ©° HTRI-R STAT1S LED CO 0 N.O. 0 COM CD 0 N.C. 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. MUSIC HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL L AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERA9TIN TEMPERATURE: +32'F (0' C TO 100' F (36 C) }TUMIDITY: bbbb-939 RELATIVE HUMIDITY, NON—CONDENSING HFP-11 SMOKE DETECTOR TO NEXT DEVICE OR END OF LINE DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CON,UNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (—) > DATA IN (+) > REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL > TO NEXT > ADDRESSABLE DEVICE FROM PREVIOUS , ADDRESSABLE DEVICE TBI NO COM NC EOLR yV. 470 0 0 SWITCH + - INPUT LED TSM -1 00 0 TO FAN SHUTDOWN 0 e TO NEXT ADDRESSABLE DEVICE /7n O NO 8 COM B HTRI-R "C® °/L TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTI❑N BOX---\ MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 00 0 0 ca TO NEXT DEVICE -CADDY BAR HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL .-1m / SMOKE DETECTOR TYPICAL WIRING AND MOUNTING DETAILS SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved -J r)CO (�\ O` J ▪ o r- D (n `< Li_ L.LI ._I LJJ (_) - -J jl f) - 1— (n cv yr) L. RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE N 0i 0 til 0 C9 z 0 0 z 0 z aa§ EF CALE: NOT TO SCAL� DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/1 9/ 17 BACKROUND PLAN PROVIDED BY: \OB NUMBER::"%6455-1_, r SHEET FA -02 A B C D E F G H J K FIRE ALARM BOOSTER Project: LIDS STORE #5102 WSCM Panel: EXISTING PAD -3 REMOTE Date: October 19, 2017 Module/Device POWER T.I. BOOSTER Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm. (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 ZH-MC-CW @30cd 131 Notification Appliance Load (Max. Total / mA) 0 3287 0 Total(A)= 15 Total(B)= 3427 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 3427 Total current ratings converted to amperes (line D x .001) 0.015 3.427 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH ZR -MC -CW @15cd 69 0.2854691 Add lines G and I Total Standby and Alarm AH 0.6454691 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.77456292 ZR -MC -CW @30cd 111 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: LIDS STORE #5102 WSCM T.I. Panel: EXISTING PAD -3 REMOTE POWER SUPPLY Wire Resistance 2.58 October 19, 2017 CURRENT TOTAL- 3287.00 jDate: � I a4 f t :"J z}�i i , es p p' TAT , 7l ' , ,{.;. JSA? i {FB r;`n , � t i" ,. i'x �' - ? f 1" f }L � j !q y. 4 P; b .. 'fit"! q ;`ol Y. 1 al -MC -CW @15cd 87 87 DATE � rn 1 ZH-MC-CW @30cd 131 131 0 ZH-MC-CW @75cd 222 0 7.H -MC -CW @95cd 292 0 1 ZR -MC -CW @15cd 69 69 ZR -MC -CW @30cd 111 0 DEVICES 3 TOTAL mA= 287 14 319 23.53 287 Total Wire Resistance (R) (WL * 2 )* (R/ft) 1.65 Total Device Load, Amps (1) (Tota_ l Cct Load) 0.29 Voltage Drop ( E) (E= I * R) 0.47 EOL Volflt'age - 24 - E) 23.53 tib Y' _ }, m"r,��# Y.. �U ~ `„, - '..}t;�3 int'- t i t. t? s �,. vt v, i 1 aen # tl n ii.!'', [- -{r Ems, � , jt A)Y ,( �ti 6�' f;i,'¢4..: t '�%'6A ? `'9^: $ �. .i aiJ r . . -�'.._._.�_.....,.,.�{,^§ 4 ...,. ...• DEVICES MAXIMUM LOAD TOTAL mA= 1500 14 .,...>,........,,......„.,...; �.._... .v..y.,....x..,..»f. _.......... 24.00 1500 Total Wire Resistance (R) (WL * 2 ) * (Rift) 0.00 Total Device Load, Amps (1) (Total Cct Load) 1.50 Voltage Drop (E) (E= 1* R) 0.00 EOL Voltage 24 - E) 24.00 i:'�3•��� � £ .3'r t,�,: .. . a� ��. `j B. 't31(j^-bN...7}%ke�i°.: it. ,.', ,I)l - Ir' tyT t!P. jf �. 5:3, '. b•f ,e'�• .. ....1Y `�+f �,.TI ;'?���, '�'Y gi e: �tf - i } i�•",., ., -yw,.„ i��s� s��=�+�� f., F'n' d3?'.+t u1 -i i`1 ,.: i.,� �._. {ll36���i , i. x' f� ., DEVICES MAXIMUM LOAD TOTAL mA= 1500 14 24.00 1500 Total Wire Resistance (R) • (WL * 2 )* (Rift) 0.00 Total Device Load, Amps (1) (Total Cct Load) 1.50 Voltage Drop ( E) (E= 1* R) 0.00 EOL Voltage 24 - E) 24.00 CALCULATIONS IDS STO FACP Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps D,I 1 S3-1 15Cd HT -R 21 TSM S3-2 30Cd SINGLE LINE DIAGRAM S3-3 15Cd EOL S3 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. WASHINGTON 1J RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE � rn 0 o IZwo °Uc o u)© I I LL O�UJQ Ci w U Q o w J E On - 0 co N TONS & SINGLE LINE DIAGRA SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/19/i 7 BACKROUND PLAN PROVIDED BY: �0B NUMBER: 2545fill} SHEET FA -03 Proprietary and Confidential, Coeyright 2013 by Guardian Security Systems, Inc. All Rights Reserved TO EXISTING TENANT JUNCTION BOX 101 t.TOCKROOM H - OPE 16'-6" .EF. S3-1 60-57/8" LEASE UNE ] • SOFFIT — , :GYP. BD: 8"-1" A.F.F. SOFFIT ,GYP. BD. 8"-2" A.F.F. I [ADJACENT TENANT 100 SALES AREA ACT -01 111 –0" A.F.F. • I - I 100 r SALES AREA 1ACT-01BI 10'4' A.F.F. 100 SALES AREA t.IILLVIORK FIXTly-113/4" A.F.F. ADJACENT TENANT 9 S3-JII 3 15Cd FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 100 SOFFIT GYP. BD. 12'– 101/2 AFF 100 SOFFIT :GYP. BD. 10'-0" AFF (ix MALLCONCOURSE ; C", F.t) Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 11 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION I SHOP DRAWINGS DATE N 0, 0 (0 co w co O co < -0 CC w W < 1- 0 — o (1) 1- 0 co CALE: /4"= '0'" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:10/19/ 7 BACKROUND PLAN PROVIDED BY J0E3 NUMBER:26455-1} I SHEET FA -04