PP - 993 SOUTHCENTER MALL - BASKIN ROBBINS ICE CREAM STORE - PERMITS AND PLANS
993 SOUTHCENTER MALL ASSOCIATED PERMITS 12-F-034 Ott"44 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: WP% q l� Site Address: 1� 3 Sc,���M(Q„�••r Mda� 1 H ActSuite Number: Floor: Tenant Name: l a`S ecgi)New Tenant? ❑ - Yes ® - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Rca,@ oke-Ak Ki I k Day Telephone: (206) 2,5112 6% Company Name: a'dua.-, S_ (i M ' q Mailing Address: 143 k" t S I W� I t �` City State Zip E-mail Address: f 1S1 k� c.k&if-CO et cu-r't'� • �� Fax Number: 0219c) ' -3M 1 lc( 2 g Valuation of Project (contractor's bid price): $ ? / 5 0 Scope of Work (please provide detailed information): /Vital vx oti y►Q 4,^ c(e_ki i CES kTh 1\"42 S?a cG . PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 02-I V S712 Print Name: I\ d f c w} Kitte Day Telephone: C'Z ° Ei 1 3 S (\ Z 6 a Plan Permit App.doc 5/14/10 TFD FP Form 8 SHEET NUMBER SHEET TITLE BASKIN BOBBINS FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON FA -01 SYSTEV INFORMATION FA -02 TYPICAL WIRI\ G A\D MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS A\D SINGLE LINE DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX ,<,.. 4:673. f Without Comments • As Noted in Red o Per The Attached Letter These pians have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design reser totally with the designer. Additions, deletions or revisions to :hese drawings after this date will void this acceptance and will require a resubmittal of revise,+ arawings for subsea ent approval. Final acceptance is sub,ect to field test and inspection by The Tukwila Fire Prevention Bureau. Date: IC?" 0-�.- WIRE TUKWILA FIRE DEPARNENT Please call 206-575-4407 and give this fire Permit No. l2-- and exact address for shut- down or restorationpprovl., NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. EDULE AND CONDUIT SCH FILL CHA RT WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR - RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 1 1 2 2 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING ® D DUCT DETECTOR AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD Di FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND macys 4 LEVELS 250,407st �mrmm �n Icw 18DE8 39 6,1 _� aNA,9T z SUKil30S !'V: CCL 1Y 1R3 UC'1 � E»R[R' STLYNQ 11E ItkK R_+2 ER. AP, L_I ❑ ❑ z;l PEN ,C,CE JEW CPS PAJ UPLRE 1EN&�T SPACE / 728 WAtDENBX]»S Exsrcc JCPenney CRZO8 x:Frss 3 1 W:3i FAX (206) 628-L4.990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 3 0 DESCRIPTION SHOP DRAWINGS DATE 02/06/12 2aa<aa (/) O Z ISS o0 CC) mo o • wzz °C (w CC • Q (I) ©C W CO cc SD IL F - 276,46°sf xPCP: NBE EEALIiY 7..74S BASKIN ROBBINS #993 WARS : PAID FEB 15 2012 TUKWILA FIRE 4'Z -z j- SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved DATE: 02/06/12 BACKROUND PLAN PROVIDED BY: .,JOB NUMBER: SHEET FA -01 )N'; THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6011Z DEDICATED E1/EROENCY '' 1401E F ADDITIONAL SecancAmets SEE PRODUCT DOQI*ENTA110N. *CONTACT RATRIOS 4.0A 0 125VAC 4.0A 0 30VDC TD NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE - FRON XLS CONTROL PANEL DR PREVIOUS ADDRESSABLE DEVICE 0 HTRI-R O O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) 0 II O PAD -3 INPUT INPUT TROUBLE MCI NAC2 NAC3 NAC4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - (-) (+) 2, SPARE SPARE t SPARE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITHSHIELD #18 FPLIFPLR RED(JACKET) 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O O r 7.7 GROUND L (-) HTRI-R0 DRY CONTACTS TO VAV --> FAN SHUTDOWN PROVIDED BY MECH/ELEC. (+)>TO NEXT DEVICE OR STOP IF LAST DEVICE (-) DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (0R UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32' F (0.0 TO 100. F 38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS [-> ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> jl DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT 0 0 1 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE N c Lo 0 N 0 2 aaaaa O 28 J '- Z �QO) z CO co <�o Qw Zz Q <W_C CO cc rn 6 U E- rSCALE: NOT TO SCALE~ DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/06/12 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 1. SHEET \ FA -02 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved \ .. , , ,':, fFAC DDcNS, ,y , DESCRIPTION SHOP DRAWINGS Current Load: , Standby: Alarm: A a : 2 <<<CK Device Type Qty Amps Total Amps Total Total HFP-11 1 0.0022 0.0022 0.0023 0.002 AD2-P 1 0.0635 0.0635 0.064 0.064 0.030 HTR -R 2. 0.009600 0.0096 0.021 0.042 ZH-MC-CW ©30CD 2 0.131 al -MC -CW ©75CD 0.222 IZI-I-MC-CW ©95CD 0.0731 Amps 0.106 Amps .. DMG DESCRIPTION SHOP DRAWINGS came L . ' , ' 4 , : ' ,,,., ii ,- A a : 2 <<<CK Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 Z1 -1 -MC -CW ©15CD 0.0875 ZH-MC-CW ©30CD 2 0.131 al -MC -CW ©75CD 0.222 IZI-I-MC-CW ©95CD 0.292 71 -1 -HMC -CW ©115CD 0.371 IZR-MC-CW ©15CD 1 0.069 0.069 ZR -MC -W ©15CD 0.064 0.03 Amps 0.099 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.099 Amps For 5 Minutes 0.008 Amp -hours 25% Derating= 0.910 Amp -hours Total System Current Load: 0.910 Amp -hours Batt�r kt�b�1 U�d:H 12VDC , Athh�tu 7..2AH, ' , TO NEAREST EXISTING SIGNALING CIRCUIT 2C 120VAC, DEDICATED , (BY OTHERS) 1 BPS TO NEAREST EXISTING DATA LOOP SYSTEM CALCULATIONS s1 -1D 30cd 3E EOL S1 S1-2 15cd S1-3 30cd TSM Notification Appliance Circuit Detail BASKIN ROBBINS 1W ire Resistance 2.58 CURRENT TOTAL=I331.00 al -MC -CW @l5cd _ 2 71-wMC-,cw @3ocif, ZH-MC-CW @75cd p-wq7cyy @9e#4 JZH-MC-CW @iis9d 1 ZR-MC-cw DEVICES 3 87 0 131 262 2221 292 3711 • 69 TOTAL mA=1 3311 14 0 0 - • - • 69 - • -- -• • .1 112 1 23.811 3311 Total Wire Resistance ( R ) 1 * 2 )* (WM I 0.581 Total Device Load, Amps (1) 1 (Total Cct Load) • 0.33; , Voltage Drop ( E ) 1(E1*RL 0.191 EOL Voltage 241:- FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110VAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 23.81 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE ,.. . 0 c., 0 2 <<<CK cc 0 w z LU coZ co can o _r Zc» Z — - z co 20 ret < cc 1— CI %.01 z Z z CC w < cr) 0 CD Z cc z IN 0 0 < Lu Ca cc SI? D LE 1- 0 -J w CALE: NOT TO SCALE. DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/06/12 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM \eB NUMBER: r SHEET FA -03 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved TO NEAREST EXISTING SIGNALING CIRCUIT 2C TO NEAREST EXISTING DATA LOOP BPS EXISTING BACK OF HOUSE - NO CHANGE WALK-IN FREEZER 1'x7' CLOSET SHELVES S i fcri j "'`( S1-2 tj (15 d tc D— DESK L1_5:1_1J u1 0 bb t I/ � I 30cd EOL �Si , / Ti P.O.S. 4' HT -R TSM S1-3 STOREFRONT 0 FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS N W \ < 0 N 0 �CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/06/12 BACKROUND PLAN PROVIDED BY: \0B NUMBER: ( SHEET FA -04 J