Loading...
HomeMy WebLinkAboutPP - 810 SOUTHCENTER MALL - LIDS - PERMITS AND PLANS810 SOUTHCENTER MALL ASSOCIATED PERMITS 12-F-168 12-S-151 12-S-098 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** ON King Co. Assessor's Tax No.: 510 sook\fIcenver Tho\\ SITE LOCATI Site Address: Tenant Name �11.�A 13 eV'S Suite Number: Floor: New Tenant? ❑ - Yes ❑ - No Property Owner's Name: V3MoiMarkl j 1.PA+ %t Mailing Address: 9C) .w�� 1r� ?lv j 1P NF1 ,, L 'A 41002S City State Zip CONTACT PERSON -if there are questions about the submittal. Name: 3Q 5&\ Cc k folowisoriDay 425. gel •764,9 Telephone: Company Name: C,X'OWh ���G P�f bt �G�'101�1 j )r► C.. Mailing Address: VO ii51( 12.1j3 m a 11 Cr-,ct., Wt.. 1E4%2_ : r E-mail Address: J,e56iC1�e.Cr'ot.,.s1vCDS City Fax Number: L f 2<j.LSfri•S Valuation of Project (contractor's bid price): $ GOO.00 Scope of Work (please provide detailed information): 4Zekoca_2. arid, ?IS PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING , WNER OR AUTHORIZED AGENT: Signature: J /#1 IL' 6 2.Lil of l Date: 7412. Print Name: J�[A { `h%nsci Day Telephone: 12.5* 14 81.-A v1 Plan Permit App.doc 5/14/10 TFD FP Form 8 Pilaff SITE LOCATION Site Address: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 3 4-5-Ct Suite Number: Z� - Floor: New Tenant? Yes ❑ - No qi Tenant Name: l (.8/',L Property Owner's Name: U -4(R-0 i4A Mailing Address: l l LILO W l \ 11 Y ��AVA \ City CONTACT PERSON -if there are questions about the submittal. Name: KARINA VELIZ Company Name: GUARDIAN SECURITY SYSTEMS, INC t/i, Cdr X25 State Zip Day Telephone: 206-734-6276 x229 Mailing Address: 1743 — 1ST AVE S City E-mail Address: kveliz@guardiansecurity, corn SEATTLE. WA 98134 State Zip Fax Number: 206-341-9928 Valuation of Project (contractor's bid price): $ � 9 X) • Scope of Work (please provide detailed information): rvninta3 tow W l'[ cL { 1 v,e, Gk1 cw►v\ Zvi cam- - PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO!UZED AGENT: Signature: Print Name: Date: Day Telephone: Plan Permit App.doc 5/14/10 TFD FP Form 8 Design Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 2 - Relocate Reliable Model G5-56 Standard Response 165° Pendents 1/2 x 1/2 o 1 - Plug existing 3 - Total Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire evention Bureau for conformance with current City standards. Acceptarc,,-- is s ibj ct to errors and omissions which do not aat<ton ize violations of adopted -.endards and ordi<-.:c ::. The responsibility for the .ve;uacy of des:p;; - •otz-iiv with ite designer. to &e.se dri-mings after - ;is date will vol require a :.:;ubmittai of r pis rj 4 .. i_ Suh,wc-quent approval. acceptance is v u r. r'- test :and inspection by .e Tukwila Fire s -re qc { � 3 TUKWILA FIRE DEPARTMENT Please Aall 206-575-4407 and give this Fire Permit No. la--3-ISI and exact address for shut- down or restoration approval. RET SEIIS IH ARERC STRAP REQUIRED TOP BEAM/ C-CLAHP- WITH SET SCREW 3/8' ALL THREAD RED PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS CROWN FIRE PROTECTION INCORP ORA TED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7869 e3�‘ i a Sew6ers Southcenter Mall Tukwila, WA 98188 J1 TUK DATE: 7 I. rz _ DRAWN: Ga' SCALE: • '.' `1. bcl PAID. L-92012 HILA FIRE #"27/6,5" V U Design Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 2 - Relocate Reliable Model G5-56 Standard Response 165° Pendents 1/2 x 1/2 o 1 - Plug existing 3 - Total Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire evention Bureau for conformance with current City standards. Acceptarc,,-- is s ibj ct to errors and omissions which do not aat<ton ize violations of adopted -.endards and ordi<-.:c ::. The responsibility for the .ve;uacy of des:p;; - •otz-iiv with ite designer. to &e.se dri-mings after - ;is date will vol require a :.:;ubmittai of r pis rj 4 .. i_ Suh,wc-quent approval. acceptance is v u r. r'- test :and inspection by .e Tukwila Fire s -re qc { � 3 TUKWILA FIRE DEPARTMENT Please Aall 206-575-4407 and give this Fire Permit No. la--3-ISI and exact address for shut- down or restoration approval. RET SEIIS IH ARERC STRAP REQUIRED TOP BEAM/ C-CLAHP- WITH SET SCREW 3/8' ALL THREAD RED PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS CROWN FIRE PROTECTION INCORP ORA TED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7869 e3�‘ i a Sew6ers Southcenter Mall Tukwila, WA 98188 J1 TUK DATE: 7 I. rz _ DRAWN: Ga' SCALE: • '.' `1. bcl PAID. L-92012 HILA FIRE #"27/6,5" FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Regalia Jewelers 810 Southcenter Mall Permit No.: 12-S-151 Date: July 11, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and largar. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 ' for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. )8" Without Comments ❑ As Noted in Red ❑ Per The Attached Letter "hese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City 1andards. Acceptance is subject to errors and Missions which do not authorize violations of adopted :andards and ordinances. The responsibility for the dequacy of design rests totally with the designer. ,(editions, deletions or revisions to these drawings after this date will void this acceptance and will require a r• submittal of revised drawings for subsequent approval. gal acceptance is subject to field test and inspection by .e Tukwila Fire Prevention Bureau. :ate: -/ - /'�- By: 4 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON F L SHEET NUM3ER SHEET TITLE FA -01 SYSTEM I \ FO N ATION FA -02 FRE ALARM SYSTEM PLAN (Sc TYPICAL DETAILS TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. and exact address for shut- down or restoration approval. SHEET INDEX WISE SCHEDULE A \D CONDUIT HILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1 /2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT PRINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL MRN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE • ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORC DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARA RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ®D DUCT DETECTOR AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N /A RED AS BUILT ADD OR CHANGE N/A N/A N/A N /A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 5 LEVELS 171,275st VCTORIAS SCCIt T macy 4 LEVELS 250. 407st moi: mr•>vn:.T---- �a� Fi_ •�11�. A� AVON I1 REGALIA #810 / SPACE 232 ❑ 5-4,K5.0,3 3LVY t CC, B sea ❑ - � n Jh F.. JCPenney 27C, C. PAID JUL 302012 TUKWILA FIRE ;.r 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-651+5 RELEASE/REVISIONS IREV. BY: 0 3 0 DESCRIPTION SHOP DRAWINGS DATE 07/27/12 2 aaaaa C� Cr)Z o CI O c° C o o QMH r W W1 0 c Er ..I Og `to ccc LL � 'GALE: NOT 0 1-• 0 z DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 07/27/12 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN �7/7z 44-b Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved ,JOB NUMBER: SHEET FA -01 } e VT nn, r » ........t TO NEAREST EXISTING STROBE CIRCUIT { lit q P� FIRE ALARM SYSTEM PLAN SCALE: 7/2"=7'0" CEILIN TILE RETURN TO EXISTING L STROBE CIRCUIT FEED FROM EXISTING STROBE CIRCUIT C HORN/STROBE HORN/STROBE WIRING DETAIL oo o° SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /- HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL TYPICAL WIRING & MOUNTING DETAILS SCALE: NTS cmZ 0 W O 0-5 0' 3 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE N N N N 0 CO Z co O J� H < CL wz_ U� v (i) C Q o w ui Er coD 1 Cij -J H J a. a. cc LL SCALE: AS NOTED DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 07/27/1 2 BACKROUND PLAN PROVIDED BY: \0B NUMBER: J SHEET FA -02 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved — ADJACENT TENANT SPACE - NO WOIK T1418 AREA 'tDJACENT WT EMAIN DJACENT 4T EFROI�tT !t1AN \ _72, LEASE LNE TENANT SPACE Wra (El ACT 41- 9'-4" ADJACENT TENANT SPACE - NO WORK T1418 AREA %is • se. .s% -'/ Y" Y', ti Y' Y' Y' Y' se' se Y� V' V • • • • CONCOURSE REFLECTED CEILING PLAN 1/2" = 1'-0" s% se Y' s% Y Y Y' V' y se • • AL1111 t1N SLIDING STOREI=R:NT WIN 3!8" GLAZING ) ) ) ) (E) ADJACENT TENANT 8TO117RW TO REMAIN, MALL CONCOURSE LEASE LINE ALLt 1IN ti 8TCACEPRONr WITH 14' GLAZNG, t r . Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart O 2 — Add Reliable Model G Standard Response 165° Semi -recessed Pendents 1/2 x 1/2 O 1 — Reloate Reliable Model G Standard Response 165° Semi -recessed Pendents 1/2 x 1/2 O 2 — Plug O E — Existing pendent no change 5 — TOTAL LE. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAN/ C—CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE sWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Perrrnit No. /�-S -oc zfd exact addEess for shut- down or restoration approval. O. Y ` :ir:hut Comma irv+a itts ❑ As. Noted in a .Til , e Per ! 1Cr r\';eLl'vl tl4 L_tter. These plans have been. revit y:e, b+.� Th-.7.Tukwila Fire Prevention Bureau ;"?i_ . <_ ,;it; '`: +' • current City standards. Accer.ca rce ,; ; .,: _ ..:,d - .omissions tvhicl'i ao r r! .., .i'" +:, : t' , ' 'n: of ado ted standards and cr+;,= r :. r` 7. -.r:c{ for cine. adequacy of.des g Additions, del tio: f:..: ... .;r~rwincs -,+Tier this date will vo:d a resubmittal of revised approval Final acceptance is subject to i _!sc i ono inspection by The Tukwila Fire Prevention bureau. Date: ((— to By: Site Plan `tvm inc. c CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 .tJ sieur.•+" r / y5 ti `d,4On Sp ``1N. 141.°4'811Dcze ' Regalia 810 Southcenter Tukwila, WA 98188 DATE: g .2:12 DRAWN: or SCALE: .I Z. • PAID 4t Mt.. -A2 2012 TUKWILA FIRE- FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Regalia 810 Southcenter Mall Permit No.: 12-S-098 Date: May 11, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 ' for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximm of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/ inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. ReIiabkd Bulletin 110 Rev.S Model G Automatic Sprinklers Spray Upright, Spray Pendent And Conventional Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construction. The fusible alloy is captured in the cylinder of the solder capsule by a stainless steel ball. When the fusible alloy melts, the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler. When this happens, the lever is released to spring free from the sprinkler so that all of the operating parts clear from the waterway allowing the deflector to distribute the discharging water. Except for the parts in the cylinder as mentioned above, the sprinkler components are made from copper. based alloys for maximum corrosion protection. Lead plated, wax coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by markings that appear on several of the operating parts and by an identifying color that appears on the frame. Sprinkler Types Standard Upright - This deflector configuration is normally used with exposed piping installations. Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and uniformly filled with water in the form of small drops or spray. Standard Pendent - This deflector configuration is normally used where the space above the piping is limited or where a concealed piping installation is employed. The discharge characteristics of the standard pendent are virtually identical to the standard upright as described above. Large and Small Orifice—By varying the orifice size, a large or small orifice sprinkler is created that will distribute as much as 40% more water or 65% less water than the normal'/2" (15mm) orifice sprinkler. Conventional—This deflector configuration is used primarily in those countries where the LPC installation rules have precedence. The sprinkler is designed to distribute a portion of its water discharge upward against the ceiling with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, ordinary and extra -high hazard installations. Upright Pendent Small Orifice Upright Conventional Application and installation Standard sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice sizes, temperature ratings, deflector styles and sprinkler spacings are in accordance with the latest published standards of the National Fire Protection Association or the approving authority having jurisdiction. The sprinklers must be installed with the Reliable Model D Sprinkler Wrench. Any other type of wrench may damage the sprinkler. The approvals or listings of Reliable Automatic Sprinklers by major approving organizations are shown in the tabulated list provided on the back of this bulletin. *Patent No. 4,440,234 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 w c cp ..1 0 Technical Data Sprinkler Type "K" Factor Sprinkler Height Approvals Bright Brass Plated Black Plated Polyester Coated (2) Lead Plated Wax -Coated (3) Wax -Coated Over Lead Plated Sprinkler Identification Number (SIN) US Metric SSU °F SSP Standard -Upright (SSU) and Pendent (SSP) °C Color Ordinary 135 57 100 38 Black Ordinary 165 Deflectors Marked to Indicate Position 100 38 Uncolored Intermediate 212 100 150 66 White High )2" (15 mm) Standard Orifice with }2" NPT (RX) Thread 5.62 81.0 2 X" (73 mm) 1, 2, 3, 4, 5, 6, 7 R1025 R1015 X6" (11 mm) Small Orifice with y" NPT (R)z) Thread e" (10 mm) Small Orifice with y" NPT (R)2) Thread 4.24 2.82 61.0 40.6 2;e" (73 mm) 2 X" (73 mm) 1, 3, 1, 2, 7 3, 7 R1023 R1021 R1013 R1011 X." (8 mm) Small Orifice with 72" NPT (Ry) Thread 1.98 28.5 2 X" (73 mm) 1, 3, 7 R1022 R1012 "/32' (20 mm) Large Orifice with )2" NPT (RX) Thread 7.96 114.7 2 e" (73 mm) 1, 2, 3, 7 R1026 R1016 1%2' (20 mm) Large Orifice with X" NPT (RX)Thread 8.20 118.2 2's,6' (75 mm) 1, 2, 3, 7 R1027 R1017 20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4, 5, 6 81027 R1017 10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 4, 5, 6 R1024 R1014 Conventional—Installed in Upright or Pendent Position 10mm XLH with 10mm Thread 4.10 59.1 73 mm 5 R1074 15mm Standard Orifice with (RX) Thread 5.62 81.0 73 mm 4, 5, 6 R1075 20mm XHH with (R3,) Thread 8.20 118.2 75.4 mm 4, 5 81077 Temperature Ratings (1) Frame color does not apply to painted or plated sprinklers -Use sprinkler rating as identified on operating parts. Finishes() Maintenance Model G Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. Standard Finishes Sprinkler Maximum Ambient Special Application Finishes Bright Brass Plated Black Plated Polyester Coated (2) Lead Plated Wax -Coated (3) Wax -Coated Over Lead Plated Rating Temperature Frame (1) Classification °F °C °F °C Color Ordinary 135 57 100 38 Black Ordinary 165 74 100 38 Uncolored Intermediate 212 100 150 66 White High 286 141 225 107 Blue (1) Frame color does not apply to painted or plated sprinklers -Use sprinkler rating as identified on operating parts. Finishes() Maintenance Model G Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. Standard Finishes Bronze Chrome White (2) —All Temperature Ratings —All Temperature Ratings —All Temperature Ratings Only Frame and Deflector are Painted Special Application Finishes Bright Brass Plated Black Plated Polyester Coated (2) Lead Plated Wax -Coated (3) Wax -Coated Over Lead Plated —Only frame, deflector and cap are plated. 135°F i57°C), 165°F (74°C), 212°F (100°C) Temp. Rating. —Only frame, deflector and cap are plated. All Ternp. Ratings. —Only frame and deflector are coated. —165°F (74°C), 212°F (100°C) and 286°F (141°C) Temp. Ratings. —165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. —165°F —165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. (1) Other colors and finishes are available. Consult factory for details. 2) UL listed and NYC MEA Approved only. 3) 212°F (100°C) brown wax may be used on 286°F (141 °C) sprinklers when maximum ambient temperatures do not exceed 150°F (66°C). UL Listed, FM Approved, NYC MEA 258-93-E. Approval Organizations 1. Underwriters Laboratories, Inc. 2. Factory Mutual Research Corporation 3. Underwriters' Laboratories of Canada 4. Loss Prevention Council 5. Pleniere Assemblee 6. VdS Schadenverhutung 7. N.Y.C. BS&A No. 587 -75 -SA or N.Y.C. MEA 258-93-E Ordering Information Specify 1. Model G 2. Deflector • Upright • Pendent • Conventional 3. Nominal Orifice 4. Inlet Thread 5. Temperature Rating 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 (800) 848-6051 (914) 829-2042 www.reliablesprinkler.com Sales Offices Sales Fax Corporate Offices Internet Address Recycled Paper Revision lines indicate updated or new data EG. Printed'n USA 11)04 P/N 9999970005 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East �±i►�ShWit% ,w Tukwila, WA 98188 PAID 206-575-4407 Mt,Y jtl 2 2012 , Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION TU K VV i L.H AR RE Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: g Lo okhCel Suite Number: Floor: Tenant Name: '-eQL-\\D,, New Tenant? ❑ - Yes l" No Property Owner's Name: Mailing Address: CONTACT PERSON -if there are questions about the submittal. Name: je5sScrL 691 relc--)Th Day Telephone: 2-. - ((J / Company Name: 'PO Lon_ �1f-e..- }rO+-e(-1-I* n` )%%C.,. Mailing Address: PC) IFI::>C)X \'Z\\-, 1\\ C...:C._14'X , 1).'V\ cnt &2 , \��SsCo.@c�roLL) .0©i ' i E-mail Address: )�)'-) Fax Number: ZS • City State Zip State Zi �g1Cn9S Valuation of Project (contractor's bid price): $ ££ , O Scope of Work (please provide detailed information): TQC. CZ_ \/1'c CY*�. _POA rir/\A \\)G )f\ rkc\s PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: ( Date: 5 /212 Print Name: Lk—E (Q oj j j7,S (JY) Plan Permit App.doc 5/14/10 Day Telephone: 1/2q/.7 ((J7 TFD FP Form 8 810 SOUTHCENTER MALL ASSOCIATED PERMITS 12-F-168 12-S-151 12-S-098 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** ON King Co. Assessor's Tax No.: 510 sook\fIcenver Tho\\ SITE LOCATI Site Address: Tenant Name �11.�A 13 eV'S Suite Number: Floor: New Tenant? ❑ - Yes ❑ - No Property Owner's Name: V3MoiMarkl j 1.PA+ %t Mailing Address: 9C) .w�� 1r� ?lv j 1P NF1 ,, L 'A 41002S City State Zip CONTACT PERSON -if there are questions about the submittal. Name: 3Q 5&\ Cc k folowisoriDay 425. gel •764,9 Telephone: Company Name: C,X'OWh ���G P�f bt �G�'101�1 j )r► C.. Mailing Address: VO ii51( 12.1j3 m a 11 Cr-,ct., Wt.. 1E4%2_ : r E-mail Address: J,e56iC1�e.Cr'ot.,.s1vCDS City Fax Number: L f 2<j.LSfri•S Valuation of Project (contractor's bid price): $ GOO.00 Scope of Work (please provide detailed information): 4Zekoca_2. arid, ?IS PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING , WNER OR AUTHORIZED AGENT: Signature: J /#1 IL' 6 2.Lil of l Date: 7412. Print Name: J�[A { `h%nsci Day Telephone: 12.5* 14 81.-A v1 Plan Permit App.doc 5/14/10 TFD FP Form 8 Pilaff SITE LOCATION Site Address: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 3 4-5-Ct Suite Number: Z� - Floor: New Tenant? Yes ❑ - No qi Tenant Name: l (.8/',L Property Owner's Name: U -4(R-0 i4A Mailing Address: l l LILO W l \ 11 Y ��AVA \ City CONTACT PERSON -if there are questions about the submittal. Name: KARINA VELIZ Company Name: GUARDIAN SECURITY SYSTEMS, INC t/i, Cdr X25 State Zip Day Telephone: 206-734-6276 x229 Mailing Address: 1743 — 1ST AVE S City E-mail Address: kveliz@guardiansecurity, corn SEATTLE. WA 98134 State Zip Fax Number: 206-341-9928 Valuation of Project (contractor's bid price): $ � 9 X) • Scope of Work (please provide detailed information): rvninta3 tow W l'[ cL { 1 v,e, Gk1 cw►v\ Zvi cam- - PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO!UZED AGENT: Signature: Print Name: Date: Day Telephone: Plan Permit App.doc 5/14/10 TFD FP Form 8 Design Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 2 - Relocate Reliable Model G5-56 Standard Response 165° Pendents 1/2 x 1/2 o 1 - Plug existing 3 - Total Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire evention Bureau for conformance with current City standards. Acceptarc,,-- is s ibj ct to errors and omissions which do not aat<ton ize violations of adopted -.endards and ordi<-.:c ::. The responsibility for the .ve;uacy of des:p;; - •otz-iiv with ite designer. to &e.se dri-mings after - ;is date will vol require a :.:;ubmittai of r pis rj 4 .. i_ Suh,wc-quent approval. acceptance is v u r. r'- test :and inspection by .e Tukwila Fire s -re qc { � 3 TUKWILA FIRE DEPARTMENT Please Aall 206-575-4407 and give this Fire Permit No. la--3-ISI and exact address for shut- down or restoration approval. RET SEIIS IH ARERC STRAP REQUIRED TOP BEAM/ C-CLAHP- WITH SET SCREW 3/8' ALL THREAD RED PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS CROWN FIRE PROTECTION INCORP ORA TED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7869 e3�‘ i a Sew6ers Southcenter Mall Tukwila, WA 98188 J1 TUK DATE: 7 I. rz _ DRAWN: Ga' SCALE: • '.' `1. bcl PAID. L-92012 HILA FIRE #"27/6,5" V U Design Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 2 - Relocate Reliable Model G5-56 Standard Response 165° Pendents 1/2 x 1/2 o 1 - Plug existing 3 - Total Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire evention Bureau for conformance with current City standards. Acceptarc,,-- is s ibj ct to errors and omissions which do not aat<ton ize violations of adopted -.endards and ordi<-.:c ::. The responsibility for the .ve;uacy of des:p;; - •otz-iiv with ite designer. to &e.se dri-mings after - ;is date will vol require a :.:;ubmittai of r pis rj 4 .. i_ Suh,wc-quent approval. acceptance is v u r. r'- test :and inspection by .e Tukwila Fire s -re qc { � 3 TUKWILA FIRE DEPARTMENT Please Aall 206-575-4407 and give this Fire Permit No. la--3-ISI and exact address for shut- down or restoration approval. RET SEIIS IH ARERC STRAP REQUIRED TOP BEAM/ C-CLAHP- WITH SET SCREW 3/8' ALL THREAD RED PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS CROWN FIRE PROTECTION INCORP ORA TED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7869 e3�‘ i a Sew6ers Southcenter Mall Tukwila, WA 98188 J1 TUK DATE: 7 I. rz _ DRAWN: Ga' SCALE: • '.' `1. bcl PAID. L-92012 HILA FIRE #"27/6,5" FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Regalia Jewelers 810 Southcenter Mall Permit No.: 12-S-151 Date: July 11, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and largar. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 ' for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. )8" Without Comments ❑ As Noted in Red ❑ Per The Attached Letter "hese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City 1andards. Acceptance is subject to errors and Missions which do not authorize violations of adopted :andards and ordinances. The responsibility for the dequacy of design rests totally with the designer. ,(editions, deletions or revisions to these drawings after this date will void this acceptance and will require a r• submittal of revised drawings for subsequent approval. gal acceptance is subject to field test and inspection by .e Tukwila Fire Prevention Bureau. :ate: -/ - /'�- By: 4 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON F L SHEET NUM3ER SHEET TITLE FA -01 SYSTEM I \ FO N ATION FA -02 FRE ALARM SYSTEM PLAN (Sc TYPICAL DETAILS TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. and exact address for shut- down or restoration approval. SHEET INDEX WISE SCHEDULE A \D CONDUIT HILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1 /2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT PRINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL MRN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE • ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORC DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARA RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ®D DUCT DETECTOR AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N /A RED AS BUILT ADD OR CHANGE N/A N/A N/A N /A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 5 LEVELS 171,275st VCTORIAS SCCIt T macy 4 LEVELS 250. 407st moi: mr•>vn:.T---- �a� Fi_ •�11�. A� AVON I1 REGALIA #810 / SPACE 232 ❑ 5-4,K5.0,3 3LVY t CC, B sea ❑ - � n Jh F.. JCPenney 27C, C. PAID JUL 302012 TUKWILA FIRE ;.r 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-651+5 RELEASE/REVISIONS IREV. BY: 0 3 0 DESCRIPTION SHOP DRAWINGS DATE 07/27/12 2 aaaaa C� Cr)Z o CI O c° C o o QMH r W W1 0 c Er ..I Og `to ccc LL � 'GALE: NOT 0 1-• 0 z DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 07/27/12 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN �7/7z 44-b Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved ,JOB NUMBER: SHEET FA -01 } e VT nn, r » ........t TO NEAREST EXISTING STROBE CIRCUIT { lit q P� FIRE ALARM SYSTEM PLAN SCALE: 7/2"=7'0" CEILIN TILE RETURN TO EXISTING L STROBE CIRCUIT FEED FROM EXISTING STROBE CIRCUIT C HORN/STROBE HORN/STROBE WIRING DETAIL oo o° SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /- HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL TYPICAL WIRING & MOUNTING DETAILS SCALE: NTS cmZ 0 W O 0-5 0' 3 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE N N N N 0 CO Z co O J� H < CL wz_ U� v (i) C Q o w ui Er coD 1 Cij -J H J a. a. cc LL SCALE: AS NOTED DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 07/27/1 2 BACKROUND PLAN PROVIDED BY: \0B NUMBER: J SHEET FA -02 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved — ADJACENT TENANT SPACE - NO WOIK T1418 AREA 'tDJACENT WT EMAIN DJACENT 4T EFROI�tT !t1AN \ _72, LEASE LNE TENANT SPACE Wra (El ACT 41- 9'-4" ADJACENT TENANT SPACE - NO WORK T1418 AREA %is • se. .s% -'/ Y" Y', ti Y' Y' Y' Y' se' se Y� V' V • • • • CONCOURSE REFLECTED CEILING PLAN 1/2" = 1'-0" s% se Y' s% Y Y Y' V' y se • • AL1111 t1N SLIDING STOREI=R:NT WIN 3!8" GLAZING ) ) ) ) (E) ADJACENT TENANT 8TO117RW TO REMAIN, MALL CONCOURSE LEASE LINE ALLt 1IN ti 8TCACEPRONr WITH 14' GLAZNG, t r . Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart O 2 — Add Reliable Model G Standard Response 165° Semi -recessed Pendents 1/2 x 1/2 O 1 — Reloate Reliable Model G Standard Response 165° Semi -recessed Pendents 1/2 x 1/2 O 2 — Plug O E — Existing pendent no change 5 — TOTAL LE. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAN/ C—CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE sWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Perrrnit No. /�-S -oc zfd exact addEess for shut- down or restoration approval. O. Y ` :ir:hut Comma irv+a itts ❑ As. Noted in a .Til , e Per ! 1Cr r\';eLl'vl tl4 L_tter. These plans have been. revit y:e, b+.� Th-.7.Tukwila Fire Prevention Bureau ;"?i_ . <_ ,;it; '`: +' • current City standards. Accer.ca rce ,; ; .,: _ ..:,d - .omissions tvhicl'i ao r r! .., .i'" +:, : t' , ' 'n: of ado ted standards and cr+;,= r :. r` 7. -.r:c{ for cine. adequacy of.des g Additions, del tio: f:..: ... .;r~rwincs -,+Tier this date will vo:d a resubmittal of revised approval Final acceptance is subject to i _!sc i ono inspection by The Tukwila Fire Prevention bureau. Date: ((— to By: Site Plan `tvm inc. c CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 .tJ sieur.•+" r / y5 ti `d,4On Sp ``1N. 141.°4'811Dcze ' Regalia 810 Southcenter Tukwila, WA 98188 DATE: g .2:12 DRAWN: or SCALE: .I Z. • PAID 4t Mt.. -A2 2012 TUKWILA FIRE- FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Regalia 810 Southcenter Mall Permit No.: 12-S-098 Date: May 11, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 ' for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximm of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/ inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. ReIiabkd Bulletin 110 Rev.S Model G Automatic Sprinklers Spray Upright, Spray Pendent And Conventional Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construction. The fusible alloy is captured in the cylinder of the solder capsule by a stainless steel ball. When the fusible alloy melts, the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler. When this happens, the lever is released to spring free from the sprinkler so that all of the operating parts clear from the waterway allowing the deflector to distribute the discharging water. Except for the parts in the cylinder as mentioned above, the sprinkler components are made from copper. based alloys for maximum corrosion protection. Lead plated, wax coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by markings that appear on several of the operating parts and by an identifying color that appears on the frame. Sprinkler Types Standard Upright - This deflector configuration is normally used with exposed piping installations. Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and uniformly filled with water in the form of small drops or spray. Standard Pendent - This deflector configuration is normally used where the space above the piping is limited or where a concealed piping installation is employed. The discharge characteristics of the standard pendent are virtually identical to the standard upright as described above. Large and Small Orifice—By varying the orifice size, a large or small orifice sprinkler is created that will distribute as much as 40% more water or 65% less water than the normal'/2" (15mm) orifice sprinkler. Conventional—This deflector configuration is used primarily in those countries where the LPC installation rules have precedence. The sprinkler is designed to distribute a portion of its water discharge upward against the ceiling with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, ordinary and extra -high hazard installations. Upright Pendent Small Orifice Upright Conventional Application and installation Standard sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice sizes, temperature ratings, deflector styles and sprinkler spacings are in accordance with the latest published standards of the National Fire Protection Association or the approving authority having jurisdiction. The sprinklers must be installed with the Reliable Model D Sprinkler Wrench. Any other type of wrench may damage the sprinkler. The approvals or listings of Reliable Automatic Sprinklers by major approving organizations are shown in the tabulated list provided on the back of this bulletin. *Patent No. 4,440,234 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 w c cp ..1 0 Technical Data Sprinkler Type "K" Factor Sprinkler Height Approvals Bright Brass Plated Black Plated Polyester Coated (2) Lead Plated Wax -Coated (3) Wax -Coated Over Lead Plated Sprinkler Identification Number (SIN) US Metric SSU °F SSP Standard -Upright (SSU) and Pendent (SSP) °C Color Ordinary 135 57 100 38 Black Ordinary 165 Deflectors Marked to Indicate Position 100 38 Uncolored Intermediate 212 100 150 66 White High )2" (15 mm) Standard Orifice with }2" NPT (RX) Thread 5.62 81.0 2 X" (73 mm) 1, 2, 3, 4, 5, 6, 7 R1025 R1015 X6" (11 mm) Small Orifice with y" NPT (R)z) Thread e" (10 mm) Small Orifice with y" NPT (R)2) Thread 4.24 2.82 61.0 40.6 2;e" (73 mm) 2 X" (73 mm) 1, 3, 1, 2, 7 3, 7 R1023 R1021 R1013 R1011 X." (8 mm) Small Orifice with 72" NPT (Ry) Thread 1.98 28.5 2 X" (73 mm) 1, 3, 7 R1022 R1012 "/32' (20 mm) Large Orifice with )2" NPT (RX) Thread 7.96 114.7 2 e" (73 mm) 1, 2, 3, 7 R1026 R1016 1%2' (20 mm) Large Orifice with X" NPT (RX)Thread 8.20 118.2 2's,6' (75 mm) 1, 2, 3, 7 R1027 R1017 20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4, 5, 6 81027 R1017 10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 4, 5, 6 R1024 R1014 Conventional—Installed in Upright or Pendent Position 10mm XLH with 10mm Thread 4.10 59.1 73 mm 5 R1074 15mm Standard Orifice with (RX) Thread 5.62 81.0 73 mm 4, 5, 6 R1075 20mm XHH with (R3,) Thread 8.20 118.2 75.4 mm 4, 5 81077 Temperature Ratings (1) Frame color does not apply to painted or plated sprinklers -Use sprinkler rating as identified on operating parts. Finishes() Maintenance Model G Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. Standard Finishes Sprinkler Maximum Ambient Special Application Finishes Bright Brass Plated Black Plated Polyester Coated (2) Lead Plated Wax -Coated (3) Wax -Coated Over Lead Plated Rating Temperature Frame (1) Classification °F °C °F °C Color Ordinary 135 57 100 38 Black Ordinary 165 74 100 38 Uncolored Intermediate 212 100 150 66 White High 286 141 225 107 Blue (1) Frame color does not apply to painted or plated sprinklers -Use sprinkler rating as identified on operating parts. Finishes() Maintenance Model G Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. Standard Finishes Bronze Chrome White (2) —All Temperature Ratings —All Temperature Ratings —All Temperature Ratings Only Frame and Deflector are Painted Special Application Finishes Bright Brass Plated Black Plated Polyester Coated (2) Lead Plated Wax -Coated (3) Wax -Coated Over Lead Plated —Only frame, deflector and cap are plated. 135°F i57°C), 165°F (74°C), 212°F (100°C) Temp. Rating. —Only frame, deflector and cap are plated. All Ternp. Ratings. —Only frame and deflector are coated. —165°F (74°C), 212°F (100°C) and 286°F (141°C) Temp. Ratings. —165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. —165°F —165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. (1) Other colors and finishes are available. Consult factory for details. 2) UL listed and NYC MEA Approved only. 3) 212°F (100°C) brown wax may be used on 286°F (141 °C) sprinklers when maximum ambient temperatures do not exceed 150°F (66°C). UL Listed, FM Approved, NYC MEA 258-93-E. Approval Organizations 1. Underwriters Laboratories, Inc. 2. Factory Mutual Research Corporation 3. Underwriters' Laboratories of Canada 4. Loss Prevention Council 5. Pleniere Assemblee 6. VdS Schadenverhutung 7. N.Y.C. BS&A No. 587 -75 -SA or N.Y.C. MEA 258-93-E Ordering Information Specify 1. Model G 2. Deflector • Upright • Pendent • Conventional 3. Nominal Orifice 4. Inlet Thread 5. Temperature Rating 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 (800) 848-6051 (914) 829-2042 www.reliablesprinkler.com Sales Offices Sales Fax Corporate Offices Internet Address Recycled Paper Revision lines indicate updated or new data EG. Printed'n USA 11)04 P/N 9999970005 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East �±i►�ShWit% ,w Tukwila, WA 98188 PAID 206-575-4407 Mt,Y jtl 2 2012 , Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION TU K VV i L.H AR RE Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: g Lo okhCel Suite Number: Floor: Tenant Name: '-eQL-\\D,, New Tenant? ❑ - Yes l" No Property Owner's Name: Mailing Address: CONTACT PERSON -if there are questions about the submittal. Name: je5sScrL 691 relc--)Th Day Telephone: 2-. - ((J / Company Name: 'PO Lon_ �1f-e..- }rO+-e(-1-I* n` )%%C.,. Mailing Address: PC) IFI::>C)X \'Z\\-, 1\\ C...:C._14'X , 1).'V\ cnt &2 , \��SsCo.@c�roLL) .0©i ' i E-mail Address: )�)'-) Fax Number: ZS • City State Zip State Zi �g1Cn9S Valuation of Project (contractor's bid price): $ ££ , O Scope of Work (please provide detailed information): TQC. CZ_ \/1'c CY*�. _POA rir/\A \\)G )f\ rkc\s PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: ( Date: 5 /212 Print Name: Lk—E (Q oj j j7,S (JY) Plan Permit App.doc 5/14/10 Day Telephone: 1/2q/.7 ((J7 TFD FP Form 8