PP - 812 SOUTHCENTER MALL - CATHY JEAN INC - PERMITS AND PLANS
812 SOUTHCENTER MALL ASSOCIATED PERMITS 14-F-012 14-S-005 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: C> Sok" ! ► U�C.ffr\v Mal I l Suite Number: Floor: Tenant Name: V-v-P_s t) New Tenant? 4- Yes ❑ - No Property Owner's Name: V') --e \ \\Ck_ Yf iflt1 rn Mailing Address: U�5 L \ ') \cv-Ao, 1! City State Zip CONTACT /PERSON -if there are questionsstabout the submittal. �i Name: L')'C \ l �d1" J1 f' fl Day Telephone: ''2 ''4 I ' 7(0( 69 Company Name: CY `L�Uoh c\l t n , \ nC, p Mailing Address: ?.n.?(\ \3 \ l Crete- l WfC `� 0 OEZ City Zip tate Z E-mail Address: L.1P,\,C__� ( CAD W ('CSYY1 Fax Number: 112S -''at • Zip Ataj q, Pd. c x4e l0 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ \ CI ()O. Scope of Work (please provide detailed information): M cV al , \ oCa 10 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Plan Permit App.doc kss/la RoI7'n? Day Telephone: Date: ' q• 1t2/13 TFD FP Form 8 deite"44 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address: 812 Southcenter Mall Space 236 Suite Number: Floor: Tenant Name: Fuego New Tenant? 0 - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina VeIIZ Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address: 1743 First Ave South, Seattle, WA 98134 E-mail Address: kveliz@guardiansecurity.com Total number of new/relocated devices or sprinkler heads: City State Zip Fax Number: 206.628.4990 c� Valuation of Project (contractor's bid price): $ 2500 Scope of Work (please provide detailed information): Adding 6 devices to existing FACP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING,i) ER OR RUTH ZED AGENT: Signature: ' Date: 1 1 `L Print Name: Karina VeliZ v Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 Customer SKECHERS 457 SOUTHCENTER MALL 'KWILA, WA 98188 GUARDIAN SECURITY LIFE. AN.O PROPERTY .PROTECTION Project SKECHERS Project # 54545 Vendor Guardian Security Systems Inc 1743 1st Ave. South Seattle, WA 98134 Phone .#...(206)622-6545 Fax # (206)6284990. Type. of Equipment FIRE ALARM List of Materials Date: April 17, 2008 Item Qty. Manuf. Model .. Description Unit Pri Total Price 1) 2). ;. . 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) <: 21) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) 33)- 34) 35) 36) 37) 38) 39) 40).. 41)_: 42) 43) 44) 45) 46) 47) 48). 49) 50) Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens HFP-11-relay AD2-P HTRI-R SET CW,W ZR-HMC-CW,W ZR-MC-CW,W SET-MC-CW,W PAD -3 DSM Photoelectric Smoke Detector w/HR relay base Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 Supervised Addressable Output Relay Module Interior Audible Speaker Annunciator Interior Visual Strobe Annunciator Interior Visual Strobe Annunciator Combination Speaker/Strobe Power Supply for Strobes with Standby** Dual Synch Module DLC Allowance Data Module* Card& chassis/252 data add Amplication Allowance * ZAC-40 /80 add to strobes. " PAD -3 with BT -33 Conduit Systems: All smoke removal and detection and control devices in an approved metallic raceway and all devices in conduit per Standard Design per NFPA 13, Ordinary Hazard Group 2, Retail All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 5 -Add Reliable Model G5-56 Standard Response 165° Concealed Pendents 1/2 x 1/2 (white) o 4 - Add Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 o 10 - Relocate from pendent Globe Model GL5661 Standard Response 155° Brass Uprights I/2 x 19 - Total (E) ADJACENT TENANT SPACE - NO WORK THIS AREA —\ / ADJACEN TENAN EXISTING LIGHTING TO —� REMAIN ,.-4I(11 c.tr: „ssc;scv A Ab') ADJACENT TENANT 000 5'- 72' / 19'-C" REFLECTED C SCALE -1/4" = 1'-0" FILING PLAN MALL COMMON Q0 - 0 _Without Comments 0 As Noted in Red Per The Attached Letter -these plans have been reviewed by The Tukwila Fire .7revention Bureau toy conformance with current City. standards. Acceptance is subject to errors and:. -:.nisslons which do not authorize Violations of adopted -. andards and ordinances. the responsibility for the: adequacy of design, rests totally with the designer. 'ydditions, deletions Or revislons.to these drawings after. this date will void this ,acceptance and will .require a .resubmittal of revised drawings for subsequent approval. "Ina: acceptance Is sublect-to field test and inspection by ae Tukwila Fire Prevention Bureau. ;ate: l s i By: TUKWILA FIRE DEPARTMENT call 206-575-4407 and Ova this Fire Permit N0. ��-►�- oos'. avd exact address for shut- down Or rem RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TUP BEAM/ C—CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING HANGER DETAIL NTS VICINITY MAP WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER.SYSTE John J. Abel 9 • I .+591 -CG • Leve: 3 Fire • •tectian . Inc: NF`I LL CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 14ILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7689 DATE: SOU THCEN TER SHOPPING CENTER 812 Sou th cen ter Mall PAID SPACE 236 JAN 13 2013 Seattle WA 98188 TUKWILA FIRE DRAWN: Orr SCALE: ' I j y . FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Fuego 812 Southcenter Mall Permit No.: 14-S-005 Date: January 15, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2' inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preation systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. FUEGO FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON With: ,ft Corilm^:r 3 ❑ As Nor:epi ; ❑ Per The Attacl k:..d Letter These plans have been reviewed by The Tukwila Fire Preveririon Bureau for conformance with current City standards: Acceps ante is subject to errors and omissions which rio not authorize violation: of adopted standaras and ordinances. The responsibility for the adequacy of design rests tocally with the designer. Additic,ns, deietior. i;r :.evisions to these drawings after this a e will void this acceptance and will require a resubmittal of revised drawings for subsequent approval.. Fina! acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: -707- I By: SHEET NUMBED SHEET TITLE FA -01 SYSTEM INFO N ATION FA -02 TYPICAL WI \G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LI \ E D IAG AM FA -04 FRE ALA M SYSTEM PLAN SHEET INDEX WIRE SCHEDULE A\ID CONDUIT FILL CHAT[ WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 . SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WTH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX EX 1 1 2 2 SYMBOL DESCRIPTION MODEL TUKWILA FIRE DEPARTMENT' Manse call 206-575-4407 and oat -as Fire Permit NO. sad exact address for ut- down or restoration aripmal. NOTICE 4 cornpi�c ;, signed, Tukwila Fire Department Pre-test Certificate: must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Deletion Systems. Failure of test will result n a Re -inspection Fee artd r MANUFACTURER BACKBOX 11 MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1G RING CEILING DUCT DETECTOR D AD2-P W/ SIEMENS DUCT HOUSING HFP-11 DET. VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM DI HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 171,275sf (7081557 1 .1 Rp:E :=s APi1a1!PIE YA E/Z8 WALDEN maty 4 LEVELS 250,407sf SCAIRS .57 rev,.1? s EfzAS VLf 0.,11 SrAPBJCCS PANCm1A 9871? 541.8E w ty UFAITO 1 E NX 4v;P FUEGO #812 / SPACE #236 9851 Bur uc111 4950 0! EE��� S.}(0 Y x4D ? 17'••5 9114 511:915 9107 5++715 BASIC PM9 •.S SITE PLAN T•E 0270 10 9 matt I I GATEUWMAND '981'7 19140 [NCA.(,: SS r▪ r EXS118G 8111 PIBB0H 0,50 It81, CtiAly 0&.441 fREO 8(0544 81 I .E111E75 w i 7 JCPenney 3 1155 ES 275,468sf E PAID JAN 17 2013 TUKWILA FIRE 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: M 0 DESCRIPTION SHOP DRAWINGS r� o 0 2 aaaaa J Z 0 17 - co zWco 0Ur a) 5Z O �QO 0 Wim= W cn LL2w' <=>. W I LI_ F/11 --° W 0) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 16/ 14 BACKROUND PLAN PROVIDED BY: 1013 NUMBER: 7781-� SHEET F" ` Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved _O 1 J/ 17171a .2g 2-03 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6012 DEDICATED EMERGENCY '' NO1E: FOR AOOIOON& S?ECIFICATIORS SEE PRODUCT DO0AENTAJON. CONTACT RATINGS 4.0A 0 125VAC 4.OA 0 30VDC nip4WItcr 10 NEXT ADDRESSABLE (+ DEVICE STIP If LAST DEVICE - FROM XLS CONTROL PANEL' DR PREVIOUS ADDRESSABLE DEVICE O ° O I GRoufw HTRI—R O el O ° O NOTE: FOR ADDITIONAL SPECIRCA1IONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 1 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) 00 00 U I1 0 PAD -3 00° INPUT INPUT TROUBLE NAC1 NAM NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - (—) (+) SPARE ?, SPARE eSPARE (—) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTEDPAIRWITHSHIELD #18 FPUFPLR RED(JACKET) *CONTACT RA1INGS: 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O O GROUND 1: *T1.1 "0 HTRI—R I kc (-) (+)> TO NEXT DEVICE OR STOP IF LAST DEVICE () DRY CONTACTS TO VAV —. FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY u � HORN/STROBE OR STROBE ONLY u u HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS 41 CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER 11N( TEMPERA RE: +32' F (0' C TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE [DATA IN ( )>— DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (—) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING z- HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX e At. Ate ...Iv" !e514. -e fedi', • -<''i: . i Si 4i1%*., O O ; TO NEXT DEVICE JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT CADDY BAR ,EJ SMOKE/HEAT DETECTOR - SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL 1743 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 0 2a<aaa CO C) N Z Wco � p v ,— o�z O Q J O < (.0 LL cn zs `I U� CC W � T. O1 - N T 0 �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 16/ 14 BACKROUND PLAN PROVIDED BY: .1OB NUMBER: 7781-1} % SHEET FA -02 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved \ J Notification Appliance Circuit Detail PROJECT: Panel: Date: FUEGO EXISTING PAD -3 POWER SUPPLY 1Wire Resistance 2.58 January 16, 2014 CURRENT TOTAL= 309.00 1 1 016cd ; 87: 2H -MC -CW @30cd 131 _ 71.14VIC-CW @75cd '222 " . ZH-MC-CW @19166ccd292 al -MC -@ d . 371 87 0 222 0 01 @15cd 69 0 DEVICES !2 TOTALMA=! 309 14 Total Wire Resistance ( R) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 230 23.631 i( WL* 2 )* (Rift) totiloct Load) (E= I *2) * 1 24 ' - 309' 1.19 0.37 23.63 SYSTEM CALCULATIONS s» s,s. vr s,s. vr TO NEAREST EXISTING e.„..4 POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-1 S1-2 1 5cd 75cd SINGLE LINE DIAGRAM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. -1- 1,0 co 0' 174.3 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: ExISTINGSiEMEN 'ti xtert et- a ' tt DESCRIPTION [SHOP DRAWINGS Curren , , Current Load: 1 Standby: Alarm: 2 <<<<< Device Type Qty Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 1 AD2-P 1 0.0635 0.0635 0.064 0.064 12 HTR -R 2 0.009600 0.0096 0.021 0.042 11 0.131 ZJ4MCCW 7 CD 6 0.222 ZH-MC-CW @95CD 0.292 0.0731 Amps 0.106 Amps Notification Appliance Circuit Detail PROJECT: Panel: Date: FUEGO EXISTING PAD -3 POWER SUPPLY 1Wire Resistance 2.58 January 16, 2014 CURRENT TOTAL= 309.00 1 1 016cd ; 87: 2H -MC -CW @30cd 131 _ 71.14VIC-CW @75cd '222 " . ZH-MC-CW @19166ccd292 al -MC -@ d . 371 87 0 222 0 01 @15cd 69 0 DEVICES !2 TOTALMA=! 309 14 Total Wire Resistance ( R) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 230 23.631 i( WL* 2 )* (Rift) totiloct Load) (E= I *2) * 1 24 ' - 309' 1.19 0.37 23.63 SYSTEM CALCULATIONS s» s,s. vr s,s. vr TO NEAREST EXISTING e.„..4 POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-1 S1-2 1 5cd 75cd SINGLE LINE DIAGRAM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. -1- 1,0 co 0' 174.3 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: ExISTINGSiEMEN 'ti xtert et- a ' tt DESCRIPTION [SHOP DRAWINGS Curren , , 11 - 1 2 <<<<< Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW5CD 12 0.0875 ZH-MC-CW ©30CD 11 0.131 ZJ4MCCW 7 CD 6 0.222 ZH-MC-CW @95CD 0.292 ZH-HMC-CW ©115CD 0.371 ZR -MC -CW ©15CD 14 0.069 0.966 ZR-MC-W15CD 0.064 0.03Amps 0.996 Amps Standby CurrentLoad: 003Amps For 24 Hours 0.720 Amp -hours Alarm Current Load: 0.996 Amps For inute 0.084 Amp -hours 25% De a ng= 1.005 Amp -hours Total System Current Load: 1.005 Amp -hours Battery Iair to, U . : Notification Appliance Circuit Detail PROJECT: Panel: Date: FUEGO EXISTING PAD -3 POWER SUPPLY 1Wire Resistance 2.58 January 16, 2014 CURRENT TOTAL= 309.00 1 1 016cd ; 87: 2H -MC -CW @30cd 131 _ 71.14VIC-CW @75cd '222 " . ZH-MC-CW @19166ccd292 al -MC -@ d . 371 87 0 222 0 01 @15cd 69 0 DEVICES !2 TOTALMA=! 309 14 Total Wire Resistance ( R) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 230 23.631 i( WL* 2 )* (Rift) totiloct Load) (E= I *2) * 1 24 ' - 309' 1.19 0.37 23.63 SYSTEM CALCULATIONS s» s,s. vr s,s. vr TO NEAREST EXISTING e.„..4 POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-1 S1-2 1 5cd 75cd SINGLE LINE DIAGRAM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. -1- 1,0 co 0' 174.3 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION [SHOP DRAWINGS DATE 01/1 6/1 4 2 <<<<< CO co Zwco 0 <65 ma" z -0 < 2 71(5,_,, w w zE- eC w ui cc D co 0 w z uJ 0 z OD 0 z z0 0 w >- CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:01/16/14 BACKROUND PLAN PROVIDED BY: \eB NUMBER: 7781-1) ( SHEET FA -03 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved \ TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP HT -R I ADJACENT TENANT 000 EXISTING ELECTRICAL PANEL AND PHONE BOARD TSM S1-2 75cd NEW STOREFRONT BY MALL COMMON Ir ADJACENT TENANT 000 13'-4" 5,-7„ 19`— MALL COMMON 00 FIRE ALARM SYSTEM PLAN 00 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE to 0 co zz W o0 0 c.76 �z Q JO L) co 0 w w Wci LI. ixw cc � LL LLOI— N T 00 W �CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 16/ 14 BACKROUND PLAN PROVIDED BY: .10B NUMBER: 7781-1} SHEET FA -04 812 SOUTHCENTER MALL ASSOCIATED PERMITS 14-F-012 14-S-005 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: C> Sok" ! ► U�C.ffr\v Mal I l Suite Number: Floor: Tenant Name: V-v-P_s t) New Tenant? 4- Yes ❑ - No Property Owner's Name: V') --e \ \\Ck_ Yf iflt1 rn Mailing Address: U�5 L \ ') \cv-Ao, 1! City State Zip CONTACT /PERSON -if there are questionsstabout the submittal. �i Name: L')'C \ l �d1" J1 f' fl Day Telephone: ''2 ''4 I ' 7(0( 69 Company Name: CY `L�Uoh c\l t n , \ nC, p Mailing Address: ?.n.?(\ \3 \ l Crete- l WfC `� 0 OEZ City Zip tate Z E-mail Address: L.1P,\,C__� ( CAD W ('CSYY1 Fax Number: 112S -''at • Zip Ataj q, Pd. c x4e l0 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ \ CI ()O. Scope of Work (please provide detailed information): M cV al , \ oCa 10 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Plan Permit App.doc kss/la RoI7'n? Day Telephone: Date: ' q• 1t2/13 TFD FP Form 8 deite"44 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address: 812 Southcenter Mall Space 236 Suite Number: Floor: Tenant Name: Fuego New Tenant? 0 - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina VeIIZ Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address: 1743 First Ave South, Seattle, WA 98134 E-mail Address: kveliz@guardiansecurity.com Total number of new/relocated devices or sprinkler heads: City State Zip Fax Number: 206.628.4990 c� Valuation of Project (contractor's bid price): $ 2500 Scope of Work (please provide detailed information): Adding 6 devices to existing FACP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING,i) ER OR RUTH ZED AGENT: Signature: ' Date: 1 1 `L Print Name: Karina VeliZ v Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 Customer SKECHERS 457 SOUTHCENTER MALL 'KWILA, WA 98188 GUARDIAN SECURITY LIFE. AN.O PROPERTY .PROTECTION Project SKECHERS Project # 54545 Vendor Guardian Security Systems Inc 1743 1st Ave. South Seattle, WA 98134 Phone .#...(206)622-6545 Fax # (206)6284990. Type. of Equipment FIRE ALARM List of Materials Date: April 17, 2008 Item Qty. Manuf. Model .. Description Unit Pri Total Price 1) 2). ;. . 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) <: 21) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) 33)- 34) 35) 36) 37) 38) 39) 40).. 41)_: 42) 43) 44) 45) 46) 47) 48). 49) 50) Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens HFP-11-relay AD2-P HTRI-R SET CW,W ZR-HMC-CW,W ZR-MC-CW,W SET-MC-CW,W PAD -3 DSM Photoelectric Smoke Detector w/HR relay base Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 Supervised Addressable Output Relay Module Interior Audible Speaker Annunciator Interior Visual Strobe Annunciator Interior Visual Strobe Annunciator Combination Speaker/Strobe Power Supply for Strobes with Standby** Dual Synch Module DLC Allowance Data Module* Card& chassis/252 data add Amplication Allowance * ZAC-40 /80 add to strobes. " PAD -3 with BT -33 Conduit Systems: All smoke removal and detection and control devices in an approved metallic raceway and all devices in conduit per Standard Design per NFPA 13, Ordinary Hazard Group 2, Retail All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 5 -Add Reliable Model G5-56 Standard Response 165° Concealed Pendents 1/2 x 1/2 (white) o 4 - Add Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 o 10 - Relocate from pendent Globe Model GL5661 Standard Response 155° Brass Uprights I/2 x 19 - Total (E) ADJACENT TENANT SPACE - NO WORK THIS AREA —\ / ADJACEN TENAN EXISTING LIGHTING TO —� REMAIN ,.-4I(11 c.tr: „ssc;scv A Ab') ADJACENT TENANT 000 5'- 72' / 19'-C" REFLECTED C SCALE -1/4" = 1'-0" FILING PLAN MALL COMMON Q0 - 0 _Without Comments 0 As Noted in Red Per The Attached Letter -these plans have been reviewed by The Tukwila Fire .7revention Bureau toy conformance with current City. standards. Acceptance is subject to errors and:. -:.nisslons which do not authorize Violations of adopted -. andards and ordinances. the responsibility for the: adequacy of design, rests totally with the designer. 'ydditions, deletions Or revislons.to these drawings after. this date will void this ,acceptance and will .require a .resubmittal of revised drawings for subsequent approval. "Ina: acceptance Is sublect-to field test and inspection by ae Tukwila Fire Prevention Bureau. ;ate: l s i By: TUKWILA FIRE DEPARTMENT call 206-575-4407 and Ova this Fire Permit N0. ��-►�- oos'. avd exact address for shut- down Or rem RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TUP BEAM/ C—CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING HANGER DETAIL NTS VICINITY MAP WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER.SYSTE John J. Abel 9 • I .+591 -CG • Leve: 3 Fire • •tectian . Inc: NF`I LL CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 14ILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7689 DATE: SOU THCEN TER SHOPPING CENTER 812 Sou th cen ter Mall PAID SPACE 236 JAN 13 2013 Seattle WA 98188 TUKWILA FIRE DRAWN: Orr SCALE: ' I j y . FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Fuego 812 Southcenter Mall Permit No.: 14-S-005 Date: January 15, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2' inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preation systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. FUEGO FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON With: ,ft Corilm^:r 3 ❑ As Nor:epi ; ❑ Per The Attacl k:..d Letter These plans have been reviewed by The Tukwila Fire Preveririon Bureau for conformance with current City standards: Acceps ante is subject to errors and omissions which rio not authorize violation: of adopted standaras and ordinances. The responsibility for the adequacy of design rests tocally with the designer. Additic,ns, deietior. i;r :.evisions to these drawings after this a e will void this acceptance and will require a resubmittal of revised drawings for subsequent approval.. Fina! acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: -707- I By: SHEET NUMBED SHEET TITLE FA -01 SYSTEM INFO N ATION FA -02 TYPICAL WI \G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LI \ E D IAG AM FA -04 FRE ALA M SYSTEM PLAN SHEET INDEX WIRE SCHEDULE A\ID CONDUIT FILL CHAT[ WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 . SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WTH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX EX 1 1 2 2 SYMBOL DESCRIPTION MODEL TUKWILA FIRE DEPARTMENT' Manse call 206-575-4407 and oat -as Fire Permit NO. sad exact address for ut- down or restoration aripmal. NOTICE 4 cornpi�c ;, signed, Tukwila Fire Department Pre-test Certificate: must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Deletion Systems. Failure of test will result n a Re -inspection Fee artd r MANUFACTURER BACKBOX 11 MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1G RING CEILING DUCT DETECTOR D AD2-P W/ SIEMENS DUCT HOUSING HFP-11 DET. VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM DI HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 171,275sf (7081557 1 .1 Rp:E :=s APi1a1!PIE YA E/Z8 WALDEN maty 4 LEVELS 250,407sf SCAIRS .57 rev,.1? s EfzAS VLf 0.,11 SrAPBJCCS PANCm1A 9871? 541.8E w ty UFAITO 1 E NX 4v;P FUEGO #812 / SPACE #236 9851 Bur uc111 4950 0! EE��� S.}(0 Y x4D ? 17'••5 9114 511:915 9107 5++715 BASIC PM9 •.S SITE PLAN T•E 0270 10 9 matt I I GATEUWMAND '981'7 19140 [NCA.(,: SS r▪ r EXS118G 8111 PIBB0H 0,50 It81, CtiAly 0&.441 fREO 8(0544 81 I .E111E75 w i 7 JCPenney 3 1155 ES 275,468sf E PAID JAN 17 2013 TUKWILA FIRE 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: M 0 DESCRIPTION SHOP DRAWINGS r� o 0 2 aaaaa J Z 0 17 - co zWco 0Ur a) 5Z O �QO 0 Wim= W cn LL2w' <=>. W I LI_ F/11 --° W 0) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 16/ 14 BACKROUND PLAN PROVIDED BY: 1013 NUMBER: 7781-� SHEET F" ` Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved _O 1 J/ 17171a .2g 2-03 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6012 DEDICATED EMERGENCY '' NO1E: FOR AOOIOON& S?ECIFICATIORS SEE PRODUCT DO0AENTAJON. CONTACT RATINGS 4.0A 0 125VAC 4.OA 0 30VDC nip4WItcr 10 NEXT ADDRESSABLE (+ DEVICE STIP If LAST DEVICE - FROM XLS CONTROL PANEL' DR PREVIOUS ADDRESSABLE DEVICE O ° O I GRoufw HTRI—R O el O ° O NOTE: FOR ADDITIONAL SPECIRCA1IONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 1 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) 00 00 U I1 0 PAD -3 00° INPUT INPUT TROUBLE NAC1 NAM NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - (—) (+) SPARE ?, SPARE eSPARE (—) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTEDPAIRWITHSHIELD #18 FPUFPLR RED(JACKET) *CONTACT RA1INGS: 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O O GROUND 1: *T1.1 "0 HTRI—R I kc (-) (+)> TO NEXT DEVICE OR STOP IF LAST DEVICE () DRY CONTACTS TO VAV —. FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY u � HORN/STROBE OR STROBE ONLY u u HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS 41 CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER 11N( TEMPERA RE: +32' F (0' C TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE [DATA IN ( )>— DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (—) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING z- HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX e At. Ate ...Iv" !e514. -e fedi', • -<''i: . i Si 4i1%*., O O ; TO NEXT DEVICE JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT CADDY BAR ,EJ SMOKE/HEAT DETECTOR - SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL 1743 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 0 2a<aaa CO C) N Z Wco � p v ,— o�z O Q J O < (.0 LL cn zs `I U� CC W � T. O1 - N T 0 �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 16/ 14 BACKROUND PLAN PROVIDED BY: .1OB NUMBER: 7781-1} % SHEET FA -02 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved \ J Notification Appliance Circuit Detail PROJECT: Panel: Date: FUEGO EXISTING PAD -3 POWER SUPPLY 1Wire Resistance 2.58 January 16, 2014 CURRENT TOTAL= 309.00 1 1 016cd ; 87: 2H -MC -CW @30cd 131 _ 71.14VIC-CW @75cd '222 " . ZH-MC-CW @19166ccd292 al -MC -@ d . 371 87 0 222 0 01 @15cd 69 0 DEVICES !2 TOTALMA=! 309 14 Total Wire Resistance ( R) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 230 23.631 i( WL* 2 )* (Rift) totiloct Load) (E= I *2) * 1 24 ' - 309' 1.19 0.37 23.63 SYSTEM CALCULATIONS s» s,s. vr s,s. vr TO NEAREST EXISTING e.„..4 POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-1 S1-2 1 5cd 75cd SINGLE LINE DIAGRAM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. -1- 1,0 co 0' 174.3 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: ExISTINGSiEMEN 'ti xtert et- a ' tt DESCRIPTION [SHOP DRAWINGS Curren , , Current Load: 1 Standby: Alarm: 2 <<<<< Device Type Qty Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 1 AD2-P 1 0.0635 0.0635 0.064 0.064 12 HTR -R 2 0.009600 0.0096 0.021 0.042 11 0.131 ZJ4MCCW 7 CD 6 0.222 ZH-MC-CW @95CD 0.292 0.0731 Amps 0.106 Amps Notification Appliance Circuit Detail PROJECT: Panel: Date: FUEGO EXISTING PAD -3 POWER SUPPLY 1Wire Resistance 2.58 January 16, 2014 CURRENT TOTAL= 309.00 1 1 016cd ; 87: 2H -MC -CW @30cd 131 _ 71.14VIC-CW @75cd '222 " . ZH-MC-CW @19166ccd292 al -MC -@ d . 371 87 0 222 0 01 @15cd 69 0 DEVICES !2 TOTALMA=! 309 14 Total Wire Resistance ( R) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 230 23.631 i( WL* 2 )* (Rift) totiloct Load) (E= I *2) * 1 24 ' - 309' 1.19 0.37 23.63 SYSTEM CALCULATIONS s» s,s. vr s,s. vr TO NEAREST EXISTING e.„..4 POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-1 S1-2 1 5cd 75cd SINGLE LINE DIAGRAM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. -1- 1,0 co 0' 174.3 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: ExISTINGSiEMEN 'ti xtert et- a ' tt DESCRIPTION [SHOP DRAWINGS Curren , , 11 - 1 2 <<<<< Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW5CD 12 0.0875 ZH-MC-CW ©30CD 11 0.131 ZJ4MCCW 7 CD 6 0.222 ZH-MC-CW @95CD 0.292 ZH-HMC-CW ©115CD 0.371 ZR -MC -CW ©15CD 14 0.069 0.966 ZR-MC-W15CD 0.064 0.03Amps 0.996 Amps Standby CurrentLoad: 003Amps For 24 Hours 0.720 Amp -hours Alarm Current Load: 0.996 Amps For inute 0.084 Amp -hours 25% De a ng= 1.005 Amp -hours Total System Current Load: 1.005 Amp -hours Battery Iair to, U . : Notification Appliance Circuit Detail PROJECT: Panel: Date: FUEGO EXISTING PAD -3 POWER SUPPLY 1Wire Resistance 2.58 January 16, 2014 CURRENT TOTAL= 309.00 1 1 016cd ; 87: 2H -MC -CW @30cd 131 _ 71.14VIC-CW @75cd '222 " . ZH-MC-CW @19166ccd292 al -MC -@ d . 371 87 0 222 0 01 @15cd 69 0 DEVICES !2 TOTALMA=! 309 14 Total Wire Resistance ( R) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 230 23.631 i( WL* 2 )* (Rift) totiloct Load) (E= I *2) * 1 24 ' - 309' 1.19 0.37 23.63 SYSTEM CALCULATIONS s» s,s. vr s,s. vr TO NEAREST EXISTING e.„..4 POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-1 S1-2 1 5cd 75cd SINGLE LINE DIAGRAM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. -1- 1,0 co 0' 174.3 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION [SHOP DRAWINGS DATE 01/1 6/1 4 2 <<<<< CO co Zwco 0 <65 ma" z -0 < 2 71(5,_,, w w zE- eC w ui cc D co 0 w z uJ 0 z OD 0 z z0 0 w >- CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:01/16/14 BACKROUND PLAN PROVIDED BY: \eB NUMBER: 7781-1) ( SHEET FA -03 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved \ TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP HT -R I ADJACENT TENANT 000 EXISTING ELECTRICAL PANEL AND PHONE BOARD TSM S1-2 75cd NEW STOREFRONT BY MALL COMMON Ir ADJACENT TENANT 000 13'-4" 5,-7„ 19`— MALL COMMON 00 FIRE ALARM SYSTEM PLAN 00 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE to 0 co zz W o0 0 c.76 �z Q JO L) co 0 w w Wci LI. ixw cc � LL LLOI— N T 00 W �CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 16/ 14 BACKROUND PLAN PROVIDED BY: .10B NUMBER: 7781-1} SHEET FA -04