Loading...
HomeMy WebLinkAboutPP - 857 SOUTHCENTER MALL - HOLLISTER COMPANY - PERMITS AND PLANS857 SOUTHCENTER MALL ASSOCIATED PERMITS 19-F-154 19-F-137 08-F-109 19-S-178 19-S-143 15-S-075 15-S-072 15-S-062 08-S-076 410444 4tt CITY OF TUIKW LA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted fir plan review: **PLEASE PRINT** SITE LOCATION Site Address: O.; 7 SoViiic-eji-Ie ^ Y 7 t I I Tenant Name: \\O 11\ ' ( King Co. Assessor's Tax No_:/ Suite Number: WOO Floor: New Tenant? D- Yes - No Property Owner's Name: WP-'\--ct2 x Y 1/ m_ m� Mailing Address: CONTACT PERSON -if there are questions abort the submittal. city - State Zip Name: • kccARd o1 or) Day : Li 2 J 7f U! / Company Name: C find Mailing Address: VO t2.\ \ D X111 C e�2., UDt\ '1 SOtZ Fax Number: E-mail Address: 3e SS'C ef2)Yb NICET III number g7q L% • �Qq ms s of Tukwila 1 �� Business License number. la� • Osla S 4si Z Total number of newhelocated devices or sprinkler beads: 76" Valuation of Project (contractor's bid price): $ F5i cnn Scope of Work (please provide detailed information): _ . tCa' LIB /�. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of coasction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid rmless�the work on the site authorized by such permit is coed within 180 days ager its issuance,,or ifthe wart: authorized undue site by such pean& is suspended or abandoned fora period of 180 {lays aper the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, fir periods not more than 180 days each. The extension shall be requested in writing and justifiable cause gyrated. I HEREBY CERTIFY THAT I HAVE REP 4ND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE ORtN' AND i AM AUTHORIZED TO APPLY FOR THIS PERMIT. •t. S BUILDING OWNER OR AVM Signature- Print iC‘X -1�6fD)YECY 1 Da ', one: 731// .7W09' Plan Permit App.doc JUL9 2019 TUKWILA FIRE paw: 6..1 822/14 no FP Fonn 8' SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address: 857 Southcenter Mall, Space 1440 Suite Number: Floor: Tenant Name: Hollister New Tenant? ❑ - Yes El - No Property Owner's Name: Westfield Shopping Center Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City E-mail Address: lig `y Fax Number: 206.628.4990 State Zip Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 1200 Scope of Work (please provide detailed information): Add 1 device to existing FRCP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER OR AUTHOR' ED AGENT: Signature: . Date: - 2—q 1 15 Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 4ist SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** c 7 /E� �p ,� King Co. Assessor's Tax No.: Site Address: 57 560- ( Ina 1/ Suite Number: /17/9n Floor: Tenant Name: it // 1 S-ier New Tenant? ❑ - Yes No Property Owner's Name: w-�. c\ Yrkanacyrrvik,-k-- Co rLJ ft Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: C VASS X 0.)0) nl 1 Day Telephone: Li 2c5 ��17( Company Name: Mailing Address: E-mail Address: 3eskcae,crou3ri��n Total number of new/relocated devices or sprinkler heads: Fax Number: r2 L/7S 4 l - gtovg- Valuation of Project (contractor's bid price): $ 2, Scope of Work (please provide detailed information): C /) Re/OC�t/i'(I4 ''Y‘ PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O OR AUT RIZ + . NT: a Signature: Print Name: je Plan Permit App.doc 1/2/13 Day Telephone: Date: i'2e•IS- L422-41* 7fo(9 TFD FP Form 8 40'44 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.:q,2O2 1 CO I (� Site Addressf3l 61TI OnCp tAst-2x �Y . Suite Number: Floor: Tenant Name:A13 Property Owner's Name: V V 12 d V''l O�,i 4L\ T ( k P pk �A C17-01 State Zip New Tenant? [ Yes ❑ - No Mailing AddressTD '.)Vq-k-kU ['n 1 City CONTACT PERSON -if t ere are questions about the submittal. Name: (ek OV pl i Day Tele hone: --v, l o Company Name: el\ kCili l CUA W(1 u �c f, rn� Mailing Address:,1 J I'* -AV e , 3 A L 12 PJ City State Zip Fax Number: Con tor's City of Tukwi a NICET III number: Business License number: &J' .CSU' Total number of new/relocated devices or sprinkler heads: 31 Valuation of Project (contractor's bid price): $ t(.Q I `-t) c Scope of Work (please provide detailed information):P (1 . (' \firi-)k-e/ Y ` i Odd �vS E-mail Address. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER OR AUTHORIZED AGENT: /� Signature. ` lam '���� 272019 Date:(} ICI Print Name c _ '!>\ .lei C);(eV &u -ilk ` Ui `N ILAL hone(X 17) o 1 '� Plan Permit App.doc 8/22/14 TFD FP Form 8 PAID SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** ^ , King Co. Assessor's Tax No..Na141 \0 "/ Site Address: %5l 6D�\4 ��/\l Suite Number: Floor: Tenant Name: \« New Tenant? ❑ - Yes (, No Property Owner's Name O(l1 W()c)PiY-ki. ', Mailing Address:A A City State Zip CONTACT PERSON -if there are questions about the submittal. Namelte-i•`(k dZ,Th( V'1�'� cIDay Telephone b(Dl `P.—,�'�-nl% Company Name: hL xc c0 Ail '�Q £1k9.-. 6 i Yl 3 Mailing Address: \1U \ Ave • 6 i Q i A $ City State Zip Fax Number: Con . I /y�y i NICET III number: Business License number: ctor's City of Tukwillr .Jl Y— ( 0t (2 s 5? Total number of new/relocated devices or sprinkler heads: (.._EJ) E-mail Address Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): VttY9_ C'_\C'(V\ P -AM 066,LAA,CA c7U Nck2,NAcsi.), PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID BUILDING OWNER OR AUTHORIZED AGENT: JUL u 1 2019 TUKWILA FIRE Date:7\I I, 11 GUI tllDV/L Day Telephone(201) (M":2 -Al -VP Signature: Print Name: Plan Permit App.doc 8/22/14 TFD FP Form 8 CITY OF TUKW I.A FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION King Co. Assessor's Tax No.: 61-Z o 2- LA 7'6010 Site Address: 2S 7 S 6 3 AAA C e (\4'r mak I Suite Number. P:111 0 Floor: Tenant Name: o \\ c- L c n o Li or k New Tenant? ❑ - Yes j - No Property Owner's Name: v '(\ . b Q1 1 - r< o� (AC o Mailing Address: 2 la) Sc)J� vt C.e (l `'C ` mat City CONTACT PERSON -if there are questions about the submittal. Name: C r\ 5 V(e- OV u r\ A Company Name: Crown C .-k(---c., ? (D C Lo n Mailing Address: i o 80X lZ c t 3 ft 1)1 state zlp E-mail Address: C N sic; C? ( c r o w A ir,Q . C o City Fax Number. Li L 5 4 8( —9( q s �i (J Contrator's City of Tukwila I , ,r� NICET III mmmber: ct 7 4i1/O/ (Ii Business License number: 8 V S- V 41 I S 81 z TOL gEt State Zip Day Telephone: ti 2 S H 81— 7 % Cr (,z G-41- q.80 2Z Total number of new/relocated devices or sprinkler heads: 12 Valuation of Project (contractor's bid price): $ I] Scope of Work (please provide detailed information): O [(� Z v7 l- k r- ►ldelrfs cpc jr-e_uJ (ore -1n d I PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR`! IJA(OTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. (,� BUILDING OWNER OR AUTHORIZED AGENT: Signature: ✓ /l/ti 4 Print Name: C r) S) p ` (,b) /aril Plan Permit Appdoc 8/22/14 TFD FP Form 8 .. _a 2019 TUKWV.A /FIRE ly Telephone: Date: 7 I Z i t 1 ft FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Hollister 857 Southcenter Mall Permit No.: 19-S-143 Date: July 22, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • Weld stamps shall be inspected on the ground, before the pipe is hung. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2019 Edition. 4. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Hollister 857 Southcenter Mall Permit No.: 15-S-072 Date: May 7, 2015 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM G 635 and ASTM C 636 per section 9.2.1.3.3.2. . • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Hollister 857 Southcenter Mall Permit No.: 19-S-178 Date: September 18, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' off the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 21/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Weld stamps shall be inspected on the ground, before pipe is hung. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2019 Edition. Apr 2715 03:OOp Crown Fire Protection FAX TRANSMITTAL 4254818695 p.1 Fax No. CROWN FIRE PROTECTION, INC. Imo: 4.27.15 Fire Prevention Bureau SEM Tukwila Fire Department ! AI MIEED Demo Permit \ umhcr ut Pa2,cs including Co%er) 1 206.575.4439 4d117 W11KWILA FIRE DEPARTMENT 'h9sse call 206-575-44137 and ;v! this Fire Permit No. /nd exact a cfor shut- ..Own hut.:own or re. mo:-2Lioi) approval. 0 Urgent 0 For Review 0 Please Comment 0 Please Reply Froin Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comments Please issue a demo permit to remove (2) sprinkler heads in the store front for the tenant improvement work at the Hollister space - 857 Southcenter Mall. The building permit # D14-0223. Thanks - FIRE POOTUCTION PPw1NNL.ER SY5TEMe John J. Abed 9790-0591-03 1es13 Glow Pre . Inc. • P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425. 481.8695 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Hollister 857 Southcenter Mall Permit No.: 08-S-076 Date: March 18, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. All references are NFPA 13, 2007 Edition. THE FIRE PROTECTION INTERNATIONAL CONSORTIUM, INC. FIRE PROTECTION - LIFE SAFETY - CODE CONSULTING SECURITY - PERFORMANCE BASED DESIGN http://www.the-fpi.com September 13, 2019 Jessica Robinson President Crown Fire Protection, Inc PO BOX 12113 Mill Creek, WA 98093 RE: Fire Protection Consulting Services Fire Sprinkler Plan Review Hollister Tl 857 Southcenter Space 1440 Tukwila, WA STATUS: Approved w/ Comments Ms. Robinson: FPI has reviewed the Fire Sprinkler Submittal Package, provided by Crown Fire Protection, for the above referenced facility. The submittal package consisted of the following: 1. Fire Protection Sprinkler Plans (Sheet 1 through 4 of 4) dated 8/15/19 and associated hydraulic calculations. Flow test data for the plans and calculations was provide by Crown. The review resulted in the following comments: 1. Prior to submittal for permitting, add Crown's state Level Ill fire sprinkler contractor stamp. 2. No Seismic bracing or calculations were provided or reviewed. No new pipe of 2 'N or larger diameter was added for this TI. Please feel free to contact me with any questions. Sincerely, Digitally signed by Carl Cart Anderson, PE Anderson, PE Date: 2°19.09.13 13:45:49 -07'00' Carl P. Anderson, PE The Fire Protection International Consortium, Inc. PmlKtion / Cons;ain ;g 11 March 2008 John Abel Crown Fire Protection PO Box 12113 Mill Creek, WA 98012 RE: Westfield Mall — Hollister Co. (Suite #1440) Independent Third Party Review — Fire Sprinkler System Dear John: Tuazon Engineering, PLLC 4322 NE 7" Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. It is noted that the sprinkler system modifications shown are to Zone T4 fed from the East Riser Room. The following was reviewed: • Fire Sprinkler Drawings — Sheet 1 dated 3/08 • Hydraulic Calculations dated 3/10/08 The documents were reviewed for compliance with the 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. The "general notes" and "design criteria" on the drawing reference 2002 and 1999 editions of NFPA 13. The correct edition is the 2007 edition per City of Tukwila Ordinance 2050, Section 16.42.020. 2. Provide restraint of all branchline piping per 2007 NFPA 13 Para 9.3.6, as enforced by the City of Tukwila. 3. Provide oversized escutcheons at sprinkler ceiling penetrations per IBC/ASCE 7 if/as required by the City of Tukwila. It is noted that flexible sprinkler connections have been used in other tenant improvement projects to satisfy this requirement. 4. Include applicable product data with the permit submittal to the City of Tukwila. 5. The hydraulic calculations conflict with the shell and core calculations by Western States Fire Protection, and don't accurately reflect the riser and underground piping. The shell and core calculations are available through the Westfield tenant coordinator (Marcia Peddicord, 206-802-6071) and should be used in future tenant improvement designs. Although there is sufficient safety margin that this will not affect final pipe sizing, the following changes are to the calculations are recommended: a. Water supply should be 140 psi static, with 10,900 gpm flowing at 20 psi residual. b. Existing 4" diameter aboveground piping is schedule 40 steel. Revise inside diameter to 4.26" in lieu of 4.310" used. c. Add 8" diameter (8.329" ID) at 27'-9" for riser room piping (includes equivalent lengths for fittings). d. Add 10" diameter (10.020" ID) at 124'-1" for riser room piping (includes equivalent lengths for fittings). e. Add 10" Wilkins 350 BFP losses (see attached data sheet). f. Add 10" diameter (10.400" ID) at 246'-6" for underground piping to water source. Westfield Mall — Hollister Co. Third Party Review — Fire Sprinkler Systems 11 March 2008 Page 2 A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or ericCa).tuazon.com with any questions regarding this review. Respectfully, TUAZON ENGINEERING, PLLC Eric P. Tuazon, PE Fire Protection Engineer Hydraulic Calculations for Project Name: HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL Location: Drawing No: C Sheet 1 REV2 1 OF 1 Date 03/14/08 Job: HOLLISTE Design: Occupancy classification: Density: Area of application: Coverage per sprinkler: ORDINARY HAZARD GP 2 0.20 gpm/sq.ft. 1500 square feet 130 S.F. MAX Type of sprinklers calculated: K=5.6 No. of sprinklers calculated: 19 heads Hose streams: 250.0 gpm Outside Hose Total water required: Including hose streams 93.20 psi @ 754.2 gpm @ Supply 139.14 psi available @ 754.2 gpm Below curve by 45.94 psi Type of System: Wet Water Supply Information: 140.00 psi Static, 20.00 psi Residual @ 10900.0 gpm Name of Contractor: CROWN FIRE PROTECTION Phone Number: 425-481-7669 Authority Having Jurisdiction: NFPA Notes: Program: 'HydroCalc' by Micro Space Systems www.MicroSpaceSystems.com ■System demand = 93.20 psi with 754.2 gpm flowing. 01 0 - 1 CD CD O O U1 O CD O O O CO a CO 0 -n O -13G) 01 O Q N CD CD CD Pressure (PSI) a CD o CD 0 0 0 CO J r -t -I. H L CO a1 -1 + a r J t L L r r f_ _ - _ y + - L J r - r J 1 L J f. O ✓ r m m L -♦ 0 n m m ii m U7 11 m r r m C fv 58-I.N aaayS 6Iewwn5 1sa j "IA HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 Sheet 3. CROWN FIRE PROTECTION Description of Fitting abbreviations Code Description T Tee E Ninety degree elbow VE Victaulic ninety degree elbow B26 Wilkens Model 350A Double Check Valve Assy. GV Gate valve UE Underground ASCA ninety degree elbow UT1 Underground ASCA tee: flow in run, flow out bullhead only Description of Other abbreviations Code Description AO Arm -over BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction A.5 Raised to the power of .5 (Square Root) L Actual pipe length F Fitting equivalent pipe length T Total pipe length Sheet 4 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Raw data previous to any calculations No. Code Diam Length Kfacl Kfac2 Press Elev Hose HW Vel Fittings 1 AO1 1.080 4.5 5.6 12.75 0.00 0.0 120 32 2E,1T 2 AO2 1.080 5.5 5.6 21.56 0.00 0.0 120 32 2E,1T 3 AO3 1.080 6.5 5.6 21.56 0.00 0.0 120 32 2E,1T 4 AO4 1.080 4.0 5.6 12.75 0.00 0.0 120 32 2E,1T 5 AO5 1.080 6.0 5.6 12.75 0.00 0.0 120 32 2E,1T 6 BL1 1.639 0.5 A01 0.00 0.00 0.0 120 32 7 BL1 1.639 9.5 AOl 0.00 0.00 0.0 120 32 8 BL1 1.639 15.0 A01 0.00 0.00 0.0 120 32 2E 9 BL1 1.639 10.0 AO2 0.00 0.00 0.0 120 32 10 BL1 1.639 10.0 AO2 0.00 0.00 0.0 120 32 11 BL1 1.639 39.0 AO3 0.00 0.00 0.0 120 32 1T 12 BL2 1.639 10.0 A01 0.00 0.00 0.0 120 32 13 BL2 1.639 12.0 A01 0.00 0.00 0.0 120 32 14 BL2 1.639 10.0 AO4 0.00 0.00 0.0 120 32 15 BL2 1.639 10.0 A04 0.00 0.00 0.0 120 32 16 BL2 1.639 39.0 AO3 0.00 0.00 0.0 120 32 1T 17 BL3 1.639 10.0 A01 0.00 0.00 0.0 120 32 18 BL3 1.639 9.0 AO1 0.00 0.00 0.0 120 32 2E 19 BL3 1.639 0.5 AO5 0.00 0.00 0.0 120 32 2E 20 BL3 1.639 9.5 AO5 0.00 0.00 0.0 120 32 21 BL3 1.639 0.5 AO5 0.00 0.00 0.0 120 32 22 BL3 1.639 9.5 AO5 0.00 0.00 0.0 120 32 23 BL3 1.639 39.0 AO3 0.00 0.00 0.0 120 32 iT 24 BL4 1.639 58.0 AO4 0.00 0.00 0.0 120 32 1T 25 CM1 4.026 11.0 BL1 0.00 0.00 0.0 120 32 26 CM1 4.026 4.0 BL2 0.00 0.00 0.0 120 32 1T 27 CM2 4.026 9.0 BL4 0.00 0.00 0.0 120 32 28 CM2 4.026 8.0 BL3 0.00 0.00 0.0 120 32 1T 29 BU 4.026 170.0 CM1 CM2 0.00 0.00 0.0 120 32 4VE 30 RI 4.026 18.0 BU 0.00 14.50 0.0 120 32 2VE,1T 31 RI 8.249 28.0 0.00 0.00 0.0 120 32 32 RI 10.370 125.0 0.00 0.00 0.0 120 32 1B26 33 UG 10.280 247.0 RI 0.00 0.00 0.0 140 32 3UE,1UT1,1GV 34 UG 10.280 0.0 0.00 0.00 250.0 140 32 CROWN FIRE PROTECTION. Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Sheet 5 Notes Arm -over 1 C = 120 L 4.5 PT 12.75 1 20.0=5.60(12.75)'.5 F 10.4 PE 0.00 1 20.0 1.08 2E 1T T 14.9 0.11288 PF 1.68 7.00 PT 14.43 6 B1 Jct K -factor for arm -over 1 = 20.0/(14.43)'.5 = 5.27 at Hyd Ref Pts 6 7 8 12 13 17 18 Arm -over 2 L 5.5 PT 21.56 2 26.0=5.60(21.56)'.5 F 10.4 PE 0.00 2 26.0 1.08 2E 1T T 15.9 0.18351 PF 2.91 9.11 PT 24.47 9 K -factor for arm -over 2 = 26.0/(24.47)'.5 = 5.26 at Hyd Ref Pts 9 10 Arm -over 3 L 6.5 PT 21.56 3 26.0=5.60(21.56)".5 F 10.4 PE 0.00 3 26.0 1.08 2E 1T T 16.9 0.18351 PF 3.10 9.11 PT 24.66 11 K -factor for arm -over 3 = 26.0/(24.66)'.5 = 5.24 at Hyd Ref Pts 11 16 23 Arm -over 4 L 4.0 PT 12.75 4 20.0=5.60(12.75)A.5 F 10.4 PE 0.00 4 20.0 1.08 2E 1T T 14.4 0.11288 PF 1.62 7.00 PT 14.37 14 K -factor for arm -over 4 = 20.0/(14.37)'.5 = 5.28 at Hyd Ref Pts 14 15 24 C = 120 B1 Jct C = 120 B1 Jct C = 120 B1 Jct CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Sheet 6 Notes Arm -over 5 C = 120 L 6.0 PT 12.75 5 20.0=5.60(12.75)'.5 F 10.4 PE 0.00 5 20.0 1.08 2E 1T T 16.4 0.11288 PF 1.85 7.00 PT 14.60 19 Bl Jct K -factor for arm -over 5 = 20.0/(14.60)'.5 = 5.23 at Hyd Ref Pts 19 20 21 22 Branchline No. 1 (Beginning pressure increased due to Hyd Ref Pt 9) C = 120 L 0.5 PT 20.09 6 AO1 23.6=5.27(20.09)A.5 F 0.0 PE 0.00 6 23.6 1.64 T 0.5 0.02012 PF 0.01 3.59 L 9.5 PT 20.10 7 AO1 23.6=5.27(20.10)'.5 F 0.0 PE 0.00 7 47.2 1.64 T 9.5 0.07254 PF 0.69 7.18 L 15.0 PT 20.79 8 AO1 24.0=5.27(20.79)A.5 F 8.7 PE 0.00 8 71.2 1.64 2E T 23.7 0.15522 PF 3.68 10.83 L 10.0 PT 24.48 9 AO2 26.0=5.26(24.48)A.5 F 0.0 PE 0.00 9 97.2 1.64 T 10.0 0.27606 PF 2.76 14.78 L 10.0 PT 27.24 10 AO2 27.4=5.26(27.24)A.5 F 0.0 PE 0.00 10 124.7 1.64 T 10.0 0.43721 PF 4.37 18.96 L 39.0 PT 31.61 11 AO3 29.4=5.24(31.61)'.5 F 8.7 PE 0.00 11 154.1 1.64 1T T 47.7 0.64719 PF 30.89 23.43 PT 62.50 25 Cross main Jct K -factor for branchline no. 1 = 154.1/(62.50)A.5 = 19.49 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Sheet 7 Notes Branchline No. 2 (Beginning pressure increased due to Hyd Ref Pt 16) C = 120 L 10.0 PT 19.44 12 AO1 23.2=5.27(19.44)A.5 F 0.0 PE 0.00 12 23.2 1.64 T 10.0 0.01951 PF 0.20 3.53 L 12.0 PT 19.64 13 AO1 23.3=5.27(19.64)A.5 F 0.0 PE 0.00 13 46.6 1.64 T 12.0 0.07067 PF 0.85 7.08 L 10.0 PT 20.48 14 AO4 23.9=5.28(20.48)A.5 F 0.0 PE 0.00 14 70.4 1.64 T 10.0 0.15203 PF 1.52 10.71 L 10.0 PT 22.00 15 AO4 24.8=5.28(22.00)A.5 F 0.0 PE 0.00 15 95.2 1.64 T 10.0 0.26539 PF 2.65 14.47 L 39.0 PT 24.66 16 AO3 26.0=5.24(24.66)A.5 F 8.7 PE 0.00 16 121.2 1.64 1T T 47.7 0.41491 PF 19.80 18.43 PT 44.46 26 Cross main Jct K -factor for branchline no. 2 = l21.2/(44.46)A.5 = 18.18 Sheet 8 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 3 (Beginning pressure increased due to Hyd Ref Pt 23) C = 120 L 10.0 PT 15.52 17 AO1 20.8=5.27(15.52)'.5 F 0.0 PE 0.00 17 20.8 1.64 T 10.0 0.01584 PF 0.16 3.15 L 9.0 PT 15.68 18 AO1 20.9=5.27(15.68)A.5 F 8.7 PE 0.00 18 41.6 1.64 2E T 17.7 0.05738 PF 1.02 6.32 L 0.5 PT 16.70 19 AO5 21.4=5.23(16.70)'.5 F 8.7 PE 0.00 19 63.0 1.64 2E T 9.2 0.12364 PF 1.14 9.58 L 9.5 PT 17.84 20 AO5 22.1=5.23(17.84)'.5 F 0.0 PE 0.00 20 85.1 1.64 T 9.5 0.21573 PF 2.05 12.94 L 0.5 PT 19.89 21 AO5 23.4=5.23(19.89)'.5 F 0.0 PE 0.00 21 108.4 1.64 T 0.5 0.33782 PF 0.17 16.49 L 9.5 PT 20.06 22 AO5 23.5=5.23(20.06)A.5 F 0.0 PE 0.00 22 131.9 1.64 T 9.5 0.48523 PF 4.61 20.05 L 39.0 PT 24.67 23 AO3 26.0=5.24(24.67)A.5 F 8.7 PE 0.00 23 157.9 1.64 1T T 47.7 0.67694 PF 32.31 24.01 PT 56.98 28 Cross main Jct K -factor for branchline no. 3 = 157.9/(56.98)'.5 = 20.92 Branchline No. 4 C = 120 L 58.0 PT 14.37 24 AO4 20.0=5.28(14.37)^.5 F 8.7 PE 0.00 24 20.0 1.64 1T T 66.7 0.01481 PF 0.99 3.04 PT 15.36 27 Cross main Jct K -factor for branchline no. 4 = 20.0/(15.36)'.5 = 5.10 Sheet 9 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 1 C = 120 L 11.0 PT 62.50 25 BL1 154.1=19.49(62.50)".5 F 0.0 PE 0.00 25 154.1 4.03 T 11.0 0.00813 PF 0.09 3.88 L 4.0 PT 62.59 26 BL2 143.8=18.18(62.59)".5 F 20.0 PE 0.00 26 297.9 4.03 1T T 24.0 0.02754 PF 0.66 7.51 PT 63.25 29 Bulk Jct K -factor for Cross main 1 = 297.9/(63.25)".5 = 37.46 Cross main 2 (Beginning pressure increased due to Hyd Ref Pt 28) C = 120 L 9.0 PT 56.98 27 BL4 38.5=5.10(56.98)".5 F 0.0 PE 0.00 27 38.5 4.03 T 9.0 0.00063 PF 0.01 0.97 L 8.0 PT 56.98 28 BL3 157.9=20.92(56.98)".5 F 20.0 PE 0.00 28 196.4 4.03 1T T 28.0 0.01275 PF 0.36 4.95 PT 57.34 29 Bulk Jct K -factor for Cross main 2 = 196.4/(57.34)".5 = 25.94 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Bulk K=63.39=37.45+25.94 L 170.0 PT 63.25 29 504.2=63.39(63.25)A.5 F 27.2 PE 0.00 29 504.2 4.03 4VE T 197.2 0.07289 PF 14.37 12.71 PT 77.62 30 Sheet 10 Notes C = 120 CM 1 + CM 2 Top of Riser Riser C = 120 L 18.0 PT 77.62 30 Top of Riser F 33.6 PE 6.28 (EL= 14.50 ft) 30 504.2 4.03 2VE 1T T 51.6 0.07290 PF 3.76 12 71 L 28.0 PT 87.66 31 F 0.0 PE 0.00 31 504.2 8.25 T 28.0 0.00222 PF 0.06 3.03 L 125.0 PT 87.73 32 F 0.0 PE 0.00 32 504.2 10.37 1B26 T 125.0 0.00073 PF 5.28 1.92 1B26 = 5.19* PT 93.01 33 B.O.R. Under ground C = 140 L 247.0 PT 93.01 33 B.O.R. F 88.1 PE 0.00 33 504.2 10.28 3UE lUT1 T 335.1 0.00057 PF 0.19 1.95 1GV L 0.0 PT 93.20 34 250.0 gpm = Hose F 0.0 PE 0.00 34 754.2 10.28 T 0.0 0.00000 PF 0.00 2.92 PT 93.20 35 Supply Jct Available flow at 93.20 psi is 6552.1 gpm which is 5797.9 gpm from curve. Supply pressure available with 754.2 gpm flowing is 139.14 psi, thus system requirement is 45.94 psi below supply curve. (33.0%) HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 Sheet 11 Supply Analysis Node at Static Residual Available Total Required Source Pressure Pressure Flow Pressure Demand Pressure 35 140.00 20.00 10900.0 139.14 754.2 93.20 Node Analysis Elevation Node Type Pressure Discharge Node (ft) K -Value Source (psi) (gpm) Notes 1 14.50 Orif= 5.60 12.75 20.0 2 14.50 Orif= 5.60 21.56 26.0 3 14.50 Orif= 5.60 21.56 26.0 4 14.50 Orif= 5.60 12.75 20.0 5 14.50 Orif= 5.60 12.75 20.0 6 14.50 20.09 - 7 14.50 20.10 8 14.50 20.79 9 14.50 24.48 10 14.50 27.24 11 14.50 31.61 12 14.50 19.44 - 13 14.50 19.64 14 14.50 20.48 15 14.50 22.00 16 14.50 24.66 17 14.50 15.52 18 14.50 15.68 19 14.50 16.70 20 14.50 17.84 21 14.50 19.89 22 14.50 20.06 23 14.50 24.67 24 14.50 14.37 25 14.50 62.50 26 14.50 62.59 27 14.50 56.98 28 14.50 56.98 29 14.50 63.25 30 14.50 77.62 31 0.00 87.66 - 32 0.00 87.73 - 33 0.00 93.01 - 34 0.00 Hose 93.20 250.0 35 0.00 93.20 - HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 Sheet 12 Pipe Information Nodel Elevl Kfactor Qadd Nominal Fittings L (ft) Cfac Total Pt Pipe (ft) Hose ID F (ft) Vel Elev Pe Node2 Elev2 Qtot Actual Length T (ft) Psi/Ft Fric Pf Notes 1 1 14.50 5.60 6 14.50 20.0 1" 2E 1T L 4.5 120 Pt 12.75 F 10.4 7.0 Pe 0.00 20.0 1.08 10.4 T 14.9 0.1129 Pf 1.68 AO1:K=5.27 2 2 14.50 5.60 9 14.50 26.0 1" 2E 1T L 5.5 120 Pt 21.56 F 10.4 9.1 Pe 0.00 26.0 1.08 10.4 T 15.9 0.1835 Pf 2.91 A02:K=5.26 3 3 14.50 5.60 11 14.50 26.0 1" 2E iT L 6.5 120 Pt 21.56 F 10.4 9.1 Pe 0.00 26.0 1.08 10.4 T 16.9 0.1835 Pf 3.10 A03:K=5.24 4 4 14.50 5.60 14 14.50 20.0 1" 2E iT L 4.0 120 Pt 12.75 F 10.4 7.0 Pe 0.00 20.0 1.08 10.4 T 14.4 0.1129 Pf 1.62 A04:K=5.28 5 5 14.50 5.60 19 14.50 20.0 1" 2E 1T L 6.0 120 Pt 12.75 F 10.4 7.0 Pe 0.00 20.0 1.08 10.4 T 16.4 0.1129 Pf 1.85 A05:K=5.23 6 14.50 5.27 [23.6] 1 1/2" L 0.5 120 Pt 20.09 A01 6 F 0.0 3.6 Pe 0.00 7 14.50 23.6 1.64 T 0.5 0.0201 Pf 0.01 7 14.50 5.27 [23.6] 1 1/2" L 9.5 120 Pt 20.10 AO1 7 F 0.0 7.2 Pe 0.00 8 14.50 47.2 1.64 T 9.5 0.0725 Pf 0.69 8 8 14.50 5.27 [24.0] 1 1/2" 2E 9 14.50 71.2 1.64 L 15.0 120 Pt 20.79 A01 F 8.7 10.8 Pe 0.00 8.7 T 23.7 0.1552 Pf 3.68 9 9 14.50 5.26 [26.0] 1 1/2" 10 14.50 97.2 1.64 L 10.0 120 Pt 24.48 A02 F 0.0 14.8 Pe 0.00 T 10.0 0.2761 Pf 2.76 10 10 14.50 5.26 [27.4] 1 1/2" 11 14.50 124.7 1.64 L 10.0 120 Pt 27.24 A02 F 0.0 19.0 Pe 0.00 T 10.0 0.4372 Pf 4.37 11 11 14.50 5.24 [29.4] 1 1/2" iT 25 14.50 154.1 1.64 L 39.0 120 Pt 31.61 A03 F 8.7 23.4 Pe 0.00 8.7 T 47.7 0.6472 Pf 30.89 BL1:K=19.49 12 12 14.50 5.27 [23.2] 1 1/2" 13 14.50 23.2 1.64 L 10.0 120 Pt 19.44 AO1 F 0.0 3.5 Pe 0.00 T 10.0 0.0195 Pf 0.20 HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 Sheet 13 Pipe Information Nodel Elevl Kfactor Qadd Nominal Fittings L (ft) Cfac Total Pt Pipe (ft) Hose ID F (ft) Vel Elev Pe Node2 Elev2 Qtot Actual Length T (ft) Psi/Ft Fric Pf Notes 13 13 14.50 5.27 [23.3] 1 1/2" 14 14.50 46.6 1.64 L 12.0 120 Pt 19.64 AO1 F 0.0 7.1 Pe 0.00 T 12.0 0.0707 Pf 0.85 14 14 14.50 5.28 [23.9] 1 1/2" 15 14.50 70.4 1.64 L 10.0 120 Pt 20.48 A04 F 0.0 10.7 Pe 0.00 T 10.0 0.1520 Pf 1.52 15 15 14.50 5.28 [24.7] 1 1/2" 16 14.50 95.2 1.64 L 10.0 120 Pt 22.00 A04 F 0.0 14.5 Pe 0.00 T 10.0 0.2654 Pf 2.65 16 16 14.50 5.24 [26.0] 1 1/2" 1T 26 14.50 121.2 1.64 L 39.0 120 Pt 24.66 A03 F 8.7 18.4 Pe 0.00 8.7 T 47.7 0.4149 Pf 19.80 5L2:K=18.18 17 17 14.50 5.27 [20.7] 1 1/2" 18 14.50 20.8 1.64 L 10.0 120 Pt 15.52 AO1 F 0.0 3.2 Pe 0.00 T 10.0 0.0158 Pf 0.16 18 14.50 5.27 [20.8] 1 1/2" 2E L 9.0 120 Pt 15.68 A01 18 F 8.7 6.3 Pe 0.00 19 14.50 41.6 1.64 8.7 T 17.7 0.0574 Pf 1.02 19 14.50 5.23 [21.4] 1 1/2" 2E L 0.5 120 Pt 16.70 A05 19 F 8.7 9.6 Pe 0.00 20 14.50 63.0 1.64 8.7 T 9.2 0.1236 Pf 1.14 20 14.50 5.23 [22.1] 1 1/2" L 9.5 120 Pt 17.84 A05 20 F 0.0 12.9 Pe 0.00 21 14.50 85.1 1.64 T 9.5 0.2157 Pf 2.05 21 14.50 5.23 [23.3] 1 1/2" L 0.5 120 Pt 19.89 A05 21 F 0.0 16.5 Pe 0.00 22 14.50 108.4 1.64 T 0.5 0.3378 Pf 0.17 22 14.50 5.23 [23.4] 1 1/2" L 9.5 120 Pt 20.06 A05 22 F 0.0 20.1 Pe 0.00 23 14.50 131.9 1.64 T 9.5 0.4852 Pf 4.61 23 14.50 5.24 [26.0] 1 1/2" 1T L 39.0 120 Pt 24.67 A03 23 F 8.7 24.0 Pe 0.00 28 14.50 157.9 1.64 8.7 T 47.7 0.6769 Pf 32.31 BL3:K=20.92 24 24 14.50 5.28 [20.0] 1 1/2" 1T 27 14.50 20.0 1.64 L 58.0 120 Pt 14.37 A04 F 8.7 3.0 Pe 0.00 8.7 T 66.7 0.0148 Pf 0.99 BL4:K=5.10 HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL Pipe Information REV2 Sheet 14 Nodel Elevl Kfactor Qadd Nominal Fittings L (ft) Cfac Total Pt Pipe (ft) Hose ID F (ft) Vel Elev Pe Node2 Elev2 Qtot Actual Length T (ft) Psi/Ft Fric Pf Notes 25 14.50 19.49 [154.1] 4" L 11.0 120 Pt 62.50 BL1 25 F 0.0 3.9 Pe 0.00 26 14.50 154.1 4.03 T 11.0 0.0081 Pf 0.09 26 14.50 18.18 [143.8] 4" 1T L 4.0 120 Pt 62.59 BL2 26 F 20.0 7.5 Pe 0.00 29 14.50 297.9 4.03 20.0 T 24.0 0.0275 Pf 0.66 27 14.50 5.10 [38.5] 4" L 9.0 120 Pt 56.98 BL4 27 F 0.0 1.0 Pe 0.00 28 14.50 38.5 4.03 T 9.0 0.0006 Pf 0.01 28 14.50 20.92 [157.9] 4" 1T L 8.0 120 Pt 56.98 BL3 28 F 20.0 5.0 Pe 0.00 29 14.50 196.4 4.03 20.0 T 28.0 0.0127 Pf 0.36 29 29 14.50 30 14.50 4" 4VE L 170.0 120 Pt 63.25 CM 1 + CM 2 F 27.2 12.7 Pe 0.00 504.2 4.03 27.2 T 197.2 0.0729 Pf 14.37 30 14.50 4" 2VE iT L 18.0 120 Pt 77.62 Top of Riser 30 F 33.6 12.7 Pe 6.28 31 0.00 504.2 4.03 33.6 T 51.6 0.0729 Pf 3.76 31 0.00 8" L 28.0 120 Pt 87.66 31 F 0.0 3.0 Pe 0.00 32 0.00 504.2 8.25 T 28.0 0.0022 Pf 0.06 32 32 0.00 33 0.00 12" 504.2 10.37 L 125.0 120 Pt 87.73 F 0.0 1.9 Pe 0.00 1B26 = 5.19# T 125.0 0.0007 Pf 5.28 33 0.00 10" 3UE lUT1 L 247.0 140 Pt 93.01 33 1GV F 88.1 1.9 Pe 0.00 34 0.00 504.2 10.28 88.1 T 335.1 0.0006 Pf 0.19 34 0.00 10" L 0.0 140 Pt 93.20 34 250.0 F 0.0 2.9 Pe 0.00 35 0.00 754.2 10.28 T 0.0 0.0012 Pf 0.00 Supply J.8 — BUND SPACE METAL AND CONCRETE ALL FIRE—PROOFED STEEL NO SPRINKLERS 1" RETURN—BEND TYPICAL STEEL I—BEAM 1 1/2' BRANCH UNE PIPE METAL PAN DECK CONCRETE CEILING 3/8' EXPANSION INSERT TO EXIST FLOOR DECK 1' RING HANGAR AT EVERY ARM OVER RUN ROD TIGHT TO PIPE EG r 1 4' CROSS MAIN i SUSPENDED T—BAR CEILING TYPICAL CONCRETE FLOOR I t BLACK CONCEALED SPRINKLER HEAD FIRE PROTECTION NOTES ARE SPRINKLER SYSTEM TO PROVIDE 100% SPRINKLER COVERAGE IN ALL AREAS PER THE STATE AND LOCAL FIRE MARSHALL. WHENEVER POSSIBLE ALIGN SPRINKLER HEADS WITH LIGHT FIXTURES, AIR DEVICES AND TO CENTER OF TILE. THE PATTERN IN EACH ROOM SHALL BE CONSIDERED INDEPENDENT OF OTHER ROOMS, ROUTE ALL PIPING AROUND ELECTRICAL PANELS. COORDINATE WITH ELECTRICAL CONTRACTOR. PROVIDE SPRINKLER HEADS GUARDS IN ALL LOCATIONS SUBJECT TO DAMAGE. FABRICATION, ERECTION AND TESTING OF AL PIPING SYSTEMS SHALL BE IN ACCORDANCE WITH OWNERS GENERAL REQUIREMENTS, N.F.P.A. #13, 24, 231 & 231C, AND LOCAL CODE & AUTHORITIES. SPRINKLER PIPES FEEDING COVERAGE BELOW _STORAGE DECKS ARE TO BE FED BY ROUTHING LINES DOWN FULL HEIGHT WALLS - AROUND PERIMETER OF DECK. FULL OPEN CLEARANCE OF STORAGE DECK IS TO BE MAINTAINED. FIRE SPRINKLER SPACING NOTE: SPRINKLER HEADS ARE NOT TO EXCEED 130 SQUARE FOOT. SPACING FOR ORDINARY HAZARD OCCUPANCY SECTIO\ A 1/4"=1' DESIGN CRITERIA DESIGN AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE LOCAL BUILDING CODE, N.F.P.A. 13 (1999 EDITION), AND ALL AUTHORITIES HAVING JURISDICTION. ORDINARY HAZARD (GROUP 2) AREAS: DENSITY: DESIGN AREA: MAX SPRINKLER COVERAGE: HOSE DEMAND: DURATION: 0.20 GPM/SQ.FT MOST DEMANDING 1500 SQ. FT. 130 SQ. FT./HEAD 250 GPM 60 MINUTES SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS" 1. "SALES" AREA SPRINKLER HEADS ARE TO BE FLAT OR MATTE BLACK SEMI—RECESSED HEADS WITH FLAT OR MATTE BLACK ESCUTCHEON. BASED ON RELIABLE AND ALTERNATE MAY BE VIKING OR GRINNELL AND MUST BE APPROVED BY THE HOLLISTER CONSTRUCTION MANAGER PRIOR TO ORDERING AND ANY INSTALLATIONS. ALL EXPOSED; PIPING SHALL BE PAINTED BROWN IN COLOR AND MUST BE COORDINATED WITH ALL TRADES. 2. "PORCH" AREA SPRINKLER HEADS ARE TO BE FLAT OR MATTE BLACK SEMI—RECESSED HEADS WITH FLAT OR MATTE BLACK ESCUTCHEON. BASE BID TO BE RELIABLE MODEL OR EQUAL. 3. "NON—SALES" AREA SPRINKLER HEADS ARE TO BE WHITE CONCEALED HEADS WITH WHITE ESCUTCHEON. BASED ON RELIABLE AND ALTERNATE MAY BE VIKING OR GRINNELL. 4. "NON—SALES" OFFICE AND LAVATORY AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE. 5. "MALL BULKHEAD" AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE. THE DESIGN INTENT IN THE RETAIL STORE AREAS IS TO INSTALL THE SPRINKLERS CENTERED BETWEEN THE BATTENS MOUNTED ON THE CEILING. i PROVIDE SPRINKLER HEADS (UP RIGHT) ABOVE THE CEILING IN CONCEALED SPACES HAVING EXPOSED COMBUSTIBLE CONSTRUCTION. BRANCH LINE RESTRAINT (NEW BRANCH PIPE ONLY) A. ALL SPRINKLER SYSTEM BRANCH LINES SHALL BE RESTRAINED AGAINST EXCESSIVE MOVEMENT PER THE FOLLOWING MINIMUM CRITERIA LISTED BELOW. IF THE BRANCH LINES ALLOW PENDENT SPRINKLER HEADS TO MOVE MORE THAN 3" FROM THE STAGNANT POSITION (FROM A LIGHT PUSH) AFTER INSTALLATION OF THE SYSTEM, ADDITIONAL RESTRAINT OF THE SPRINKLER DROPS SHALL BE PROVIDED. B. BRANCH LINES UP TO 20'-0" LONG SHALL REQUIRE NO ADDITIONAL MEANS OF RESTRAINTS PROVIDED THAT THE END HANGER RESTRAINS UPWARD MOVEMENT OF THE END SPRINKLER HEAD. C. BRANCH LINES FROM 20'-0" UP TO 40'-0" LONG SHALL REQUIRE ADDITIONAL MEANS OF RESTRAINT IN BOTH THE UPWARD AND LATERAL DIRECTIONS. ADDITIONAL RESTRAINT SHALL BE AT THE LAST SPRINKLER HEAD AT THE MIDPOINT OF THE BRANCH LINE. GENERAL NOTES >> ALL ABOVE GROUND FIRE PROTECTION SYSTEMS SHALL BE HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HOURS WITH NO VISIBLE LEAKAGE. ALL CONCEALED PIPING SHALL BE AIR TESTED, WITH NO LEAKAGE, PRIOR TO FILLING SYSTEM WITH WATER. THE FIRE PROTECTION CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AUTHORITIES HAVING JURISDICTION 24 HOURS PRIOR TO THE TEST. THE ENGINEER SHALL WITNESS ALL TESTS. THE FIRE SPRINKLER SYSTEM SHALL BE SUPERVISED BY AN APPROVED CENTRAL STATION, PROPRIETARY STATION, OR REMOTE STATION MONITORING SYSTEM IN ACCORDANCE WITH N.F.P.A. 72, AND LOCAL AUTHORITY HAVING JURISDICTION. by others THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE WIRING OF ALL ELECTRICAL FIRE PROTECTION DEVICES AND EQUIPMENT WITH THE ELECTRICAL AND/OR FIRE ALARM CONTRACTOR. ALL FIRE ALARM WIRING BY ELECTRICAL CONTRACTOR. ALL DEVICES SHALL BE FURNISHED AND INSTALLED BY THE FIRE PROTECTION CONTRACTOR. THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE THE LAYOUT OF THE FIRE PROTECTION SYSTEM WITH ALL TRADES AND ARCHITECTURAL REFELECTED CEILING PLAN PRIOR TO INSTALLATION. THE FIRE PROTECTION CONTRACTOR SHALL CENTER (WITHIN 1") ALL PENDENT SPRINKLER HEADS INSTALLLED IN ACOUSTICAL LAY—IN CEILING TILES. ALL PENDANT SPRINKLER HEADS IN CEILINGS SHALL BE SYMMETRICAL WITH LIGHTING AND AIR DEVICES. SPRINKLER HEADS ARE REQUIRED ABOVE THE CEIUNG IN ALL AREAS OF CONCEALED SPACES. THE LOCATION OF EXTERIOR FIRE PROTECTION EQUIPMENT SUCH AS FIRE DEPARTMENT CONNECTIONS, TEST DRAINS, ETC., SHALL BE COORDINATED WITH THE ASSOCIATE ARCHITECT AND APPROVED BY THE LOCAL FIRE DEPARTMENT. FINAL APPROVAL IS SUBJECT TO ACCEPTANCE AND TESTING BY ALL AUTHORITITIES HAVING JURISDICTION. CONTRACTOR SHALL SEAL ALL PENETRATIONS OF FIRE RATED ASSEMBLIES (WALLS, FLOORS, ETC.) AS REQUIRED TO MAINTAIN SASSEMBLY RATING. REFER TO ARCHITECTURAL PLANS FOR FIRE RATINGS. WIRE USED FOR RESTRAINT SHALL BE LOCATED WITHIN 2 FT. OF A HANGER. THE HANGER CLOSEST TO A WIRE RESTRAINT SHALL BE OF A TYPE THAT RESIST UPWARD MOVEMENT OF A BRANCH UNE. 2—#8x1 /2" CONCRETE OVER SELF TAPPING SCREWS. OR HILTI TZ ANCHORS STEEL DECK STEEL STRA 3" WIDE x 4" LONG x 12 GAL ATR SHALL BE TIGHT TO TOP OF PIPE AT END OF UNE, TO PREVENT VERTICAL MOVEMENT D. BRANCH LINES OVER 40'-0" LONG SHALL REQUIRE ADDITIONAL MEANS OF RESTRAINT IN BOTH THE UPWARDS AND LATERAL DIRECTIONS. ADDITIONAL RESTRAINT SHALL BE AT THE LAST SPRINKLER HEAD AND AT A MAXIMUM OF 30'-0" INTERVALS ALONG THE LENGTH OF THE BRANCH LINE. E. UPWARD RESTRAINT SHALL BE PERFORMED AT EACH HANGER ASSEMBLY BY BOTTOMING OUT THE HANGING ROD AGAINST THE SPRINKLER PIPING. F. LATERAL RESTRAINT SHALL BE PERFORMED IN INTERVALS NOT EXCEEDING 3O'-0" BY ADDING RESTRAINING WIRES IN BOTH LATERAL DIRECTIONS. (SEE DETAIL ABOVE) SPLAYED SEISMIC BRACING WIRE 2 TIGHT TURNS AROUND PIE END OF LINE RESTRAINT • SPKR. LINE FOUR TIGHT TURNS PER PLAN SCALE: N.T.S. I—BEAM © ROOF --_�RFTAINFR II ACC Air .F2 D O Without Comments O As Noted in Red '6r Per The Attached Letter These plans have t'e,r reviewed by The Tukwila Fire �'revention Burek.- `°-for,nance with current City andarJs. acc ubiect to errors and ..;in isslons which c:E r :-, r. ; -Qr Sze violations of adopted ? - dards and or i. o!--- -' Tine fespohsibility for the '. ;.'quaoy of oesi * ' : e''+' with the ciesigner. Additions, deiet;c.:..�: ,__ these drawings after this date viii void •,,',:1 •,z3,: E-: and will require a re:submittai cr . i ,. •};, _ .. e. cent approval, Final acceptax: ; ei:1 1rc:=3t and inspection by The Tukwila ti ¢. „ F.:130f): i :3 r: u. Date: -12 - 19 LOt7V-g/(3-90 , IPO suolpoedcul einpegos of JequanN pulled gild 3/8" BEAM CLAMP 3/8" ATR Fire Ferm t To schedule inspections colt 206-575-4407 MALL KEY PLAN HOLLISTER Co. SPACE #1440 LEVEL 1 OF 1 NORDSTROM JCF:erPeY MI NEAREST MALL PUBLIC RESTROOM NOTE: ALL QUICK BOLTS TO BE "HILTI TZ " TYPICAL MAIN HANGER © BEAMS CONCRETE ANCHOR ALL THREAD ROD DRILLED CONC. ANCHOR HANGER p WAaHW TON rra ORRTWICAT O+< C PIR* PROTECTION SPRINKLER $Y$I*MS John Thomas DeMertino 9794 -1001 -CG Level 3 Crown Fin Protection, Inc. CROWNFP044LL REVISION 1 09/05/2019 (I; aroma REVIEWED THE FPI CONSORTIUM, INC. X_ No Comments/No Exceptions Taken Make Corrections As Noted Revise and Resubmit Reviewed for general conformance with the Design Basis. This review is not intended to authorize any work not in accordance with Code. By: ---�E ----- Date:9L1.3/201..9 SEE ATTACHED REVIEW LETTER Carl Digitally signed by Carl Anderson, PE Anderson, PE Date: 2019.09.13 13:48:48 -07'00' • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILLI CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 HOLLISTER 857 SOUTHCENTER MALL SPACE #1440 SEATTLE, WASHINGTON 98188 DATE: 08/15/2019 DRAWN: NA SCALE: NOTED 1 OF 4 Design Area 3 Wet System GUY'S 109 AND SERVICE Demand Calculations using Hazen -Williams Method Occupancy Classification: OH GP 2 Design Area Density: 0.20 Additional Outside Hose: 250 Design Area Size: 980 Notes: Calculation results for Design Area 1 - GIRLS 104 AREA 980 SQ FT MATCH EXISTING HEIGHT +/-12'-0" PRE -FIN 9,-10" C-2 P -13L WOME�J'�S 112 tufEN'S 113 WD. TRIM P -12K 10'-5 1/2" NEW SCH 10 PIPE 7'-8 3/4" GUY'S 1 103 1o'-7" C-3 P -2A 10'-0" C-6 PRE -FIN OVE MALL FLOOR EXISTIN PIPE T 1 " BRANCH ICAL 112 LOUNGE 4" CROSS MAIN NEW SCH 10 PIPE 7'-8 3/4" 1 1 •�� B 3-1-- -`2,‘,4-712 r 1 NEW SCH 10 PIPE I .cr. t 112 GIRL'S 2 10'-5 1/2" 368 RESTRAINT TYPICAL 10 PIPE i 1ACOVE FLOOR UNLESS NOTED OTHERWISE CEILING ELEVATION: 17'6" MAIN PIPE ELEVATION: 15'4" BRANCH PIPE ELEVATION: 16' ELEVATION FROM JOB REF: 0' Design Area 1 Wet System GIRLS 104 AREA Demand Calculations using Hazen -Williams Method Occupancy Classification: OH GP 2 Design Area Density: 0.20 Additional Outside Hose: 250 Design Area Size: 912 Notes: AREA RED. QR HEADS CEILING HGT 1-fT-TT-TTT7-T ItififffiffiftffitittifffflittftlEnfffili Effliftliffif NI /ITCH XISTING HEIGHT f all PRE -FIN. 1 £if it 111 MUM k f #SII L IIH Effif1 I IIb 912 SQ FT, 1056 SQ FjT NI 1 TRI P -12K v 112 v 1 r C7 s This system as shown on company print no for Job Name at contract no a maximum area of 912 ft2 Hose stream allowance of dated 2 floor area over 0.2 m/ft (L/min/m2)of a e is designed ned to discharge at a rate of 9P 9 9 when supplied with water at a rate of 285 qpm at 39.2 psi at the base of the riser. is included in the above. Occupancy classification: OH GP 2 Number of heads flowing: 13 Commodity classification: System Type: Wet Maximum storage height: Maximum velocity: 12.6 ft/s Storage arrangement: Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: 0 gpm 285 gpm 0 gpm 0 gpm 0 qpm 285 gpm 250 qpm 535 gpm Pressure Required at Source: 39.2 psi Pressure Available at Source: 144.6 psi Surplus Pressure at Source: 105.4 psi Calculation results for Design Area 2 - GIRLS 108 AREA This system as shown on company print no for Job Name at dated 2 at rate of 0.2 gpm/ft2(L/min/m2) of floor area over contract no is designed to discharge a ( ) a maximum area of 1056 ft2 when supplied with water at a rate of 335.3 qpm at 41.1 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: OH GP 2 Number of heads flowing: 17 Commodity classification: System Type: Wet Maximum storage height: Maximum velocity: 13.24 ft/s Storage arrangement: Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: O gpm 335.3 gpm 0 gpm 0 gpm 0 qpm 335.3 gpm 250 qpm 585.3 gpm Pressure Required at Source: 41.1 psi Pressure Available at Source: 143.7 psi Surplus Pressure at Source: 102.6 psi P -38B 7-11" WD. TRIM SF -29 8'-0" WOOD P-3 112 1 1- Design Area 2 Wet System GIRLS 108 AREA Demand Calculations using Hazen -Williams Method Occupancy Classification: OH GP 2 Design Area Density: 0.20 Additional Outside Hose: 250 Design Area Size: 1056 Notes: AREA RED. FOR QR HEADS AND CEILING HGT. Calculation results for Design Area 3 - GUY'S 109 AND SERVICE 0 PLAN VIEW 3/16"=1'-0" This system as shown on company print no for Job Name at dated contract no is designed to discharge at a rate of 0.2 gpm/ft2 (L/min/m2) of floor area over a maximum area of 980 ft2 when supplied with water at a rate of 265.4 qpm at 49.7 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: OH GP 2 Number of heads flowing: 13 Commodity classification: System Type: Wet Maximum storage height: Maximum velocity: 15.09 ft/s Storage arrangement: Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: O gpm 265.4 gpm 0 gpm 0 gpm 0 qpm 265.4 gpm 250 qpm 515.4 gpm Pressure Required at Source: 49.7 psi Pressure Available at Source: 145 psi Surplus Pressure at Source: 95.3 psi CEIUNG TILE SPRINKLER HEAD DETAIL OF ACCEPTABLE HEAD PLACEMENT UNLESS NOTED CENTER HEADS IN TILES AS SHOWN FITTER NOTE: ALL PENDANT SPRINKLES WITHIN ROOMS AND HALL WAYS MUST LINE UP SYMMETRICAL. FIRE PROTECTION LEGEND SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# 0 97 CONCEALED PEND BLACK 155 5.60 1/2" REUABL REUABL G5-56 0 3 CONCEALED PEND WHITE 155 5.60 1/2" R3615 REL. F1 FR 0 2 UPR BRASS 155 5.60 1/2" RA1425 REUABL F1FR56 0 4 CONCEALED PEND BLACK 155 5.60 1/2" REUABL REUABL G5-56 106 SPRINKLERS TOTAL TENANT SPRI \KLER PLAN SCALE: 3/16" = 1'-0" 1 1 1 1 1 I 0 4' 8' REVISION 1 09/05/2019 I 16' 24' • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 HOLLISTER 857 SOUTHCENTER MALL SPACE #1440 SEATTLE, WASHINGTON 98188 DATE: 08/15/2019 DRAWN: NA SCALE: NOTED 2 OF 4 0 L MATCH EXISTING HEIGHT C-1 PRE -FIN. 9'-10" C-2 P -13L WOMEN'S WD. TRIM M EN'$ 13 10'-5 1/2" C-3 P -2A 7'-8 3/4" C-3 P -13A PRE -FIN ABOVE MALL FLOOR 7'-8 3/4" C-3 9'-6" C-3 N/A GIRL'S 1 104 GIRL'' 2 10'-5 1/2" C-3 P -2A 9'-3" WD. TRIM P -12K ITTIN OGR1 ALCOVE 3101 tam tlrrr� +/-12'-0" C-1 PRE -FIN. 7'-1" C-3 C-3 P -39B P -13A MATCH EXISTING HEIGHT TENANT SPRINKLER PLAN 0 SCALE: 1 /4" = 1'-O" I I I I I I 0 4' 8' 16' 24' TRIM P -12K DEFLECTED CEILING PLAN VIEW 1/4"=1'-0" FIRE PROTECTION LEGEND SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# 97 CONCEALED PEND BLACK 155 5.60 1/2" REUABL REUABL G5-56 0 3 :ONCEALED PEND WHITE 155 5.60 1/2" R3615 REL F1 FR 0 2 UPR BRASS 155 5.60 1/2" RA1425 REUABL F1FR56 O 4 CONCEALED PEND BLACK 155 5.60 1/2" RELIABL REUABL G5-56 106 SPRINKLERS TOTAL CEILING 11LE SPRINKLER HEAD 7'-11" WD. TRIM SF -29 PRE -FIN. 8'-0" PRE -FIN. CABINET VAT h J('r DETAIL OF ACCEPTABLE HEAD PLACEMENT UNLESS NOTED CENTER HEADS IN TILES AS SHOWN FITTER NOTE: ALL PENDANT SPRINKLES WITHIN ROOMS AND HALL WAYS MUST UNE UP SYMMETRICAL. 9'-6" C-2 P -35L REVISION 1 09/05/2019 • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL; CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 HOLLISTER 857 SOUTHCENTER MALL SPACE #1440 SEATTLE, WASHINGTON 98188 DATE: 08/15/2019 DRAWN: NA SCALE: NOTED 3 OF 4 980 SQ FT 1 I I I MATCH EXISTING HEIGHT DUS1110 OUT—IN 1O CITY MAN Source Information Date of Flow Test 1 Info : 03/12/2019 Location of flow test data : SITE CLOSEST HYDRANT Source of flow test data : HOLLISTER ORIGINAL DESIGN CROWN FIRE Source Data Points Pump Data Points Pressure I Flow Pressure I Flow 150.00 0.00 20.00 3000.00 10' CI SUPPLY SOUTH MALL =NOR WAIL r t• RISER FOR 1115 SPACE II VALVE ROOM DOS= SPRNIOER RISER WOMEN'S , GUY3 NEW SOH 10 PPE EASING SPRINKLER RISER M MAN 2' 21 1112 I 0 1 I 10 �93J.E3a,PL 110 1 ' ""SEC TON R2 ! 4 'TKHHa347.V PL 4 IV -1 FR C'a3i4/ 10 10 SECTION R1 LOUNGE Y 1' SNAP -MFT 11061 NG102I RESERANT WIC,/ E)OSIIIG RISERS FOR CALCIILAINNS 1 -1 -14 -14441 -M+1+1 -1- 11-M +HfH H+H}HHfU+H I+141-1+1114114H+FHH 3FHH+IF 1 j I !MU 11+U++Ek}H{ 1 Hf a 1 WATER SUPPLY & PARTIAL SITE PLAN 1/8"=1'-0" A COVE401i■■i-� illi t111 11A.ijiP 13C� MitI I+H+I+H+ urn :1-141+I+ffl 14+14LH+H+IH-IH PLAN VIEW 3/16"=1'-0" REVISION 1 09/05/2019 CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 HOLLISTER 857 SOUTHCENTER HALL SPACE #1440 SEATTLE, WASHINGTON 98188 DATE: 08/15/2019 DRAWN: NA SCALE: NOTED 4 OF 4 EFTIED ,� Without Comments 'p As Noted in Red p Per The Attached Letter These plans have been reviewed by The Tukwila Fire evention Bureau for conformance with current City andards. 5,ccePtance is subject to errors and ::nissions hlch do not authorize violations of adopted -:zandards aid ordinances. The responsibility for the adequacy o' design rests tot-a.ily with the designer. Additions, ceietiong, to these drawings after this date wl I void th;.= :F.cceptance and will require a resubmittal r. ri { : ;�.: - fix.:bsequent approval. efi yv; Final accep Nrnce is sujeCt to Held test and inspection by The Tukwila Fire Prevention Bureau. Date: By: SHEET NUM HOLLISTER - LANDLORD WORK Fire Permit Number 1 q- F -/Y-(1 To schedule inspections call 206-575-4407 SHEET TITLE FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON FA -01 SYSTEIV INFORMATION FA -02 TYPICAL WHIN G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FLOC PLAN Fl ALARM SHEET INDEX ADD NEW FIRE ALARM DEVICES TO AN EXISTING FIRE ALARM SYSTEM SCOPE OF WORK WISE SCHE DULE A\ D CO\ DUIT FILL CHAT WIRE DESIGNATIIN SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END EXPIRES 09/01/2020 FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE A_ARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE REORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMP_ETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDAI\CE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE INVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E E E E E 3 E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP ®E D DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD E DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE E WITH RELAY (EXISTING) HTRI-R SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM STROBE (EXISTING) SLSCW-F SIEMENS 4S BOX CEILING FIRE ALARM SPEAKER STROBE (NEW) SET -MC -W SIEMENS 4S DEEP W/ 1-1 /2" EXTN 80" A.F.F. TO BOTTOM TENANT [0,_ J -BOX F.B.O. F.B.O. VERIFY IN FIELD �w A END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND ii �. NORDSTROM 3 LEVELS .71,275,1 z:E HOLLISTER -LANDLORD WORK 2800 :a:v> I.:ary I>.:, 3Asn ,mm, ml•ECTS-5 MAC :t °.r3 trx, RFs EratrIrl maty LEVELS 250:4070 '1£ =71 lE71 .J OE TAE QRS G ` C ° fT ( L106TE7. JO0 5 RESTAURANT t. At -P PAT... WIRE DESIGNATION GENERAL NOTES SITE PLAN ROW irC • 3 7.1 RELEASE/REVISIONS REV. BY: 0 m ce DESCRIPTION I SHOP DRAWINGS DATE L07/26/2019 2aaaaa JCPenney lIFEE5 3 LEVELS . 276,46Rsf PAID III= 3 1 2019 TUKWILA FRE C-6 f 2a) SCALE: NOT Z 0 0 z N )-1 TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 07/26/2019 BACKROUND PLAN PROVIDED BY: V \0B NUMBER:46595-1} SHEET FA -01 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 12OVAC-6OHZ -{ DEDICATED EMERGENCY FROM EXISTING MAIN FACP C CABLE C' CABLE �`a a GRD N L - T T L -T- Id 0 PAD -3 0 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAPA AUX 1+ - 1 2+ 2- 2 NC C NO + - + - + - + - + - S 0 1_(2111),1_ql ® M 3.6k EOL 00 0 a 0 0 (-) (+) (-) (+) HARD LID CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE NAC S4 NAC S3 NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4 SQUARE BOX CEILING MOUNTED SPEAKER/STROBE '00 00• O°p o°o o SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) STROBE SPEAKER (+) (-) FROM PREVIOUS ADDRESSABLE DEVICE TBI CX 10 NO COM NC 2 TO FAN SHUTDOWN EOLR 470 SWITCH + - INPUT LED TSM -1 00 00 0 TO NEXT ADDRESSABLE DEVICE m e Is 2 3 5 0 0 NO ® COM HTRI-R NC O 0 Oj TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (-f) STROBE SPEAKER (+) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: U m ct DESCRIPTION SHOP DRAWINGS DATE 0) 0 N CO N N. 0 u) J *.Z.0 W 0 s` zco z Occ (75 cc� I- Q O0 O _J < !•-- C� w2z `f) z< 2w� tr U CC W 0� uI-- _ O .1 8 .J N �- 0 = J U (SCALE: NOT TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 07/26/2019 BACKROUND PLAN PROVIDED BY: \OB NUMBER:46595-1i SHEET FA -02 FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project: HOLLISTER - LANDLORD WORK Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLY Date: July 26, 2019 Module/Device Qty Standby Total Standby (mA) (mA) Alarm Total Alarm (mA) (mA) Power Module 1 15 15 0 140 140 0 A TOTAL FIRE ALARM POWER SUPPLY 15 140 B Auxiliary Device Current 0: 0 C Notification Appliance Load (Max. Total / mA) 0 D E F G H J K 2418 Total(A)= CALCULATION 15 Total(B)= 2558 Total current ratings of all devices in system (line A + line B + line C) 15 2558 Total current ratings converted to amperes (line D x .001) 0.015 2.558 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.2130814 Add lines G and I Total Standby and Alarm AH 0.5730814 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.68769768 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP -HR *** Notification Appliance Circuit Detail PROJECT: HOLLISTER - LANDLORD WORK Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPL Date: July 26, 2019 Wire Resistance 2.58 CURRENT TOTAL= 2418.00 NEW 3 SET -MC -W @15cd SLSPSCW-F @30cd SLSPSCW-F @75cd SLSPSCW-F @95cd EX 12 SLSCW-F @15cd DEVICES 15 98: 294 58 171, 256 40,. TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage 0 0 0 320 614 14 420 22.67 (WL* 2 )*(R/ft) (Total Cct Load) (E=I*R) 24 - E) 614 2.17 0.61 1 22.67 EX EX 3 EX 2 SLSPSCW-F @15cd SLSPSCW-F @30cd SLSPSCW-F @75cd SLSPSCW-F @95cd SLSCW-F @75cd DEVICES .6 EX EX _ EX EX 40 58 171 256 40 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I)_ Voltage Drop ( E ) EOL Voltage 174 342 0 0 556 14 396 22.86 (WL*2)*(R/ft) (Total Cct Load) (E=I*R) 24-E 556 2.04 0.56 1.14 22.86 2 SLSPSCW-F @l5cd 1 SLSPSCW-F @30cd 2 SLSPSCW-F @75cd 3 SLSPSCW-F @95cd SLSCW-F @15cd DEVICES 8 ... _ 40 58 171. 256 40 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 80 58 342 768 0 1248 14 384 CALCULATIONS 21.53 (WL*2)*(R/ft) (Total Cct Load) (E=I*R) 24 - E) 1248 1.98 1.25 2.47 21.53 Notification Appliance Circuit Detail - VOICE PROJECT: HOLLISTER - LANDLORD WORK Panel: SPEAKER CIRCUIT IT Date: July 26, 2019 Wire Resistance 2.58 CURRENT TOTAL= 7.08 SLSPSCW @1/4-W SLSPSCW @1/2-W SLSPSCW @1-W SLSPSCW @2-W SLSPCW @1/4-W SLSPCW @1/2-W SLSPCW @1-W SLSPCW @2-W DEVICES .2 3.54 7.08 14.14 28.29 3.54 .. 7.08 14.14 28.29 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 7.08 0 0 0' 0_ 0' 0 7.08` 14 24.00 (WL*2)*(R/ft) (Total Cct Load) (E=I*R) 24 - E) 7.08 0.00 0.01 0.00 24.00 TO EXISTING HOLLISTER FIRE ALARM 2S,2 bV 2S,2V J EXISTING TENANT J -BOX S1-1 15Cd 11W 2S,2V 2S,2V b b S1-2 15Cd 1/4W S1-3 15Cd 1/4W SINGLE LINE DIAGRAM EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1Z Lu ca 0)4Jizt 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I U m DESCRIPTION SHOP DRAWINGS DATE 07/26/2019 aaaaa Iflo�°° EQ° o0Jo c J < ,;l-- � wiz Zw= cc CC w F- CO Li_ 01-- J o N O CC 0 0 W z W J 0 z (7 C,) z 0 U U W F- C/) C!) SCALE: NOT TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 07/26/2019 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 46595-12 C SHEET FA -03 S1-3 15Cd 2S,2V 2S,2V S1-2 15Cd 2S,2V S1-1 15Cd 12S2V TO EXISTING TENANT J -BOX El L ( N, FLOOR PLAN - FIRE ALARM EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS !REV. BY: RBC DESCRIPTION SHOP DRAWINGS DATE 07/26/2019 2 <<<<< (41 CC 0 co W z co 0 o crE <0) a CLZ 0-10 _1 < t; o 2 2' Lij z ci) l—zu2c w cc 0 CC w < w cc c„), IJJ LL 0 }— cocm 0 0 0 LE: 1/8"=1'0" DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE:07/26/2019 BACKROUND PLAN PROVIDED BY: .10B NUMBER:46595-1i SHEET FA -04 Without Cornrrients As .Noted- in : Red Pet- The Attache Letter plans have i eenni reviewed by The Tukwila Fire <:. •*_ration Bure uva;th currery nt.Ci •c'rds. Acte rG'•li' %. s3fl)ect:. to t -cars and :•-. ir, signs which orf Not v nlatinns of.adoptad z' . 7-,rdard4 aria ordifnanc'e:3..:. `t iF responsibfiity _for -the -•• dequacy of design i=ce 5, otZT'i`t,h te dations: drtmirigs a fe this date wlitedd re a resubrnitt; ` o i - i i'.. approval _. Final,accedtar e It. , d o :� tc iCf.?E` t and Inspection.. 6.y Tne Tukwila Ffrt .?t sC°=-i Bufeau._. gate: Fire Pcrnit:Number /01 -S-TV V To se; eciule.irtpL:c loris coil 200-575-4407 a) i BRACE 1.4 P RETAINER STRAP WHERE REM -- IN SEISMIC AREAS TOP BEAM/ C—CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING Design per NFPA 13 - Ordinary Hazard 2 All materials to be new, U.L. listed, and F.M. approved All heads to be a minimum of 6' apart and to be unobstructed by any means 0 12 - Add Globe Model GL5601 Quick Response 155° Chrome Pendents 1/2 x 1/2 12 - Total STEEL JOIST/TRUSS HANGER DETAIL NTS ' a Corrugated stainless steel hose with stainless steel braid available in 2', 3',4',5' & 6' Iegnths . • . • Multi -Port Bracket • • Adjustable Hub - • Flexheacl ommercial Ceiling Unit T -Bar Ceiling Installation - Model #2024,2036,2048,2060,2072 df, ill11111XXIOX IX I. w FIRE PROTECTION SPRINKIItR ffiY$TE MB' . John: Thomes.DeMartirw - , 9794-1O$1-.CGLeVe13 • ' a.. Crawn.Fwe Protecitan; Inc. CROWNFP044LL," X 3 FIRE PROTECTION INCORPORATED P.O:. BOX 12113 -: MILL CREEK, WASHINGTON 98082--0113 PH. (425) 481-7669 • Hollister Westfield Mall 857. Southcenter Mall Tukwila, WA DATE: 7..2_ 200 DRA SCALE: ..1).:9:=A., l SHEET \ UM 3E� SHEET TITLE FIRE ALARM SYSTEM ADDITION TU ILA, WASHINGTON FA -01 SYSTEM I\FOMATIO(\ FA -02 TYPICAL WIRING AND MOU\TI\C DETAILS FA -03 SYSTEM CALCULATIONS A\ D SINGLE LI\E DIAGRAM FA -04 FLOO PLA\ FRE ALARM SHEET INDEX ADD NEW FIRE ALARM DEVICES TO AN EXISTING FIRE ALARM SYSTEM SCOPE OF WORK WISE SCHEDUL AN CO\DUIT FILL CHAT WIRE DESIGNATION 0 M 0 SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1 /8" .60 SQUARE INCH 1-1 /2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END EXPIRES 09/01/2020 WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE A_ARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (" FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY 3 3 4 SYMBOL DESCRIPTION MODEL y! Without Comments jo As Noted in Re4. ❑ Per The Attached Letter -,ese plans have been reviewed by the Tukwila Fire :Mention Bureau fol conformance wilt current City ,dards. Acceptai(:' iF Subject to errors and disslons which do hoc ,u-horize violations of adopted 3ndards and orriinancO_-. The responsibility for the degUaCy of design f:Ot:raitiv with the e signer. Additions, deletions or i,3vIsions to these drawings after this date will void this acceptartai and will require a resubmittal of revised drawin s it,- subsequent approval. Final acceptance is sub.'s to field test and Inspection by Date: 7 -/ /-j By:. sl l Fire Permit Number )9-F-/37 To schedule inspections call 206-575-4407 MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD 12 STROBE FIRE ALARM SLSCW-F SIEMENS 4S BOX CEILING 14 FIRE ALARM g SPEAKER STROBE E SLSPSCW-F SIEMENS 4S BOX CEILING DE TENANT J -BOX F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 71 275sf 1 L' HOLLISTER 857 V. StR ZT]. n•FE.ESS uaR W ? STY! S SEARS TAIL c �.-r.tmrn.F Efil .; R , SiaJ!Z S 0 tlY,__7 1 ▪ T505 Y 4'5 .5FSi.t�R T ▪ .-C6-.V iHR 1,.:0/1:T FILPAP. ` D ..GIFT: .Ent. ,95 - l JCP• enney . • C.LF5 3 LEVELS 776.46Rs` s F_S T 4J.'Si\ FESTA:tit:- 1 T` PAn, P011,) SITE PLAN PAiD itiN 2/ tillq TUKWILA FIRF 31/ l+L rr) co 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I 0 M 0 DRAWN BY: D. GARCIA DESCRIPTION SHOP DRAWINGS T. QUAALE DATE:06/26/19 U DATE M nonilikinrD.7M-1/10_1 N N 0 2aaaaa o O � T cc o 2z 0 0 W QW� I -U ZZ i DocII oa cc co 0 LL I- ›ffi % rY,ALt: NW 1 U SCALL ` DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:06/26/19 U BACKROUND PLAN PROVIDED BY: nonilikinrD.7M-1/10_1 N Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 }k THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120YAC-60NZ - DEDICAIED BBRGENCY FROM EXISTING MAIN FACP C CABLE C' CABLE Q N C IX T 0 PAD -3 0 0 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 S 0 e u e ISI uuuuu1-9-JM G H 3.6k EOL 0 0 (—) (+) (—) (+) HARD LID CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE NAC S4 NAC S3 j NAC S2 j NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4 SQUARE BOX CEILING MOUNTED SPEAKER/STROBE '°O 00• °°0 0°0000 SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) (+) ) STROBE SPEAKER (+) (—) FROM PREVIOUS ADDRESSABLE DEVICE 2 HFP-11 TBI CD® OOTT@ 1000, NO COM NC TO FAN SHUTDOWN EOLR 470 o SWITCH + INPUT LED TSM -1 0 00 TO NEXT ADDRESSABLE DEVICE 0 //i// 2 3 5 D0 HTRI-R 0 NO B COM B NC ® ,s\° o O� TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (+) ( ) STROBE SPEAKER (+) (-) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved rn Co Cr ASHINGTON 1743 1ST AVE. SO., SEATTLE, FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: M 0 DESCRIPTION SHOP DRAWINGS w\ I- o\ 0) 0 0 CO Z O CO O) LC ©20 W < WI--- C3 W z (O„) (/) = cc g0CC CO� W LO LL I�— SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:06/26/19 BACKROUND PLAN PROVIDED BY: \OB NUMBER:38009-1J SHEET '' FA -02 J FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project: HOLLISTER Panel: NEW BPS PAD -3 REMOTE POWER SUPPLY Date: June 26, 2019 Module/Device Qty Standby Total Standby Alarm Total Alarm (mA) (mA) (mA) (mA) Power Module 1 15 15 0 140 140 0 A TOTAL FIRE ALARM POWER SUPPLY 15 140 B Auxiliary Device Current 0 0 C Notification Appliance Load (Max. Total / mA) 0 D E F G H J K 2124 Total(A)= CALCULATION 15 " Total(B)= 2264 Total current ratings of all devices in system (line A + line B + line C) 15 2264 Total current ratings converted to amperes (line D x .001) 0.015 2.264 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.1885912 Add lines G and I Total Standby and Alarm AH 0.5485912 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.65830944 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP -HR *** Notification Appliance Circuit Detail PROJECT: HOLLISTER Panel: NEW BPS PAD -3 REMOTE POWER SUPPLY Date: June 26 2019 Wire Resistance 2.58 CURRENT TOTAL= 2124.00 SLSPSCW-F @15cd SLSPSCW-F @30cd SLSPSCW-F @75cd SLSPSCW-F @95cd 12 SLSCW-F @15cd DEVICES 12 40 58 171: 256 40 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage SLSPSCW-F @15cd SLSPSCW-F @3Ocd SLSPSCW-F r@ 75cd SLSPSCW-F @95cd SLSCW-F @15cd DEVICES 6 0 320 320. 14 360 23.41 (W L.* 2 ) * (Rift) .. (Total Cct Load) (E= I * R) 24 - E) 320 1.86 0.32 0.59 23.41 40 58 174 171 342 256 0 40 0 TOTAL mA= Total Wire Resistance (R ) Total Device Load Amps (I) Voltage Drop (E ) EOL Voltage 556 14 396 22.86 (WL*2)*(R/ft) (Total Cct Load) (E- I *R)... 556 2.04 0.56 1.14 24-E 22.86 2 SLSPSCW-F @15cd SLSPSCW-0 @3Ocd SLSPSCW-F @75cd SLSPSCW- F @95cd SLSCW-F @15cd DEVICES 8 9i�4�ti the 40 58 171 256 40 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage 80 58 342 768 0 1248 14 384 21.53 1248 ( WL * 2 )* (R/ft) 1.98 (Total Cct Load) 1.25 (E=I*R) 2.47 24 - E) ' 21.53 CALCULATIONS FACP"A p Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 FDBZ492-HR 3 0.0635 0.0635 0.064 0.192 HTRI MODULE 0.00960 0.0096 0.021 0.084 0.0731 Amps 0.276 Amps Notification Appliance Circuit Detail - VOICE PROJECT: HOLLISTER Panel: SPEAKER CIRCUIT Date: June 26, 2019 Wire Resistance 2.58 CURRENT TOTAL= 74.34 7 SLSPSCW @1/4-W 7 SLSPSCW @1/2-W SLSPSCW @1-W SLSPSCW ®2-W SLSPCW @1/4-W SLSPCW @1/2-W SLSPCW @1-W SLSPCW @2-W DEVICES 14 3.54 7.08 14.14 2.8.29 3.54 7.08 14.14 28.29 TOTAL mA Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage 24.78 49.56 0 0 0' 0 74.34 14 24.00 (WL*2)*(R/ft) (Total Cct Load) (E=I*R) 24-E) 74.34 0.00 0.07 0.00 24.00 TO EXISTING SPEAKER CIRCUIT TO NEW BPS REMOTE BOOSTER POWER SUPPLY (FIELD LOCATE) 2V b 3S b S,V S S3-1 15Cd 1/4W S2-1 75Cd 1/2W S,V V S,V r S,V f S,V T S V y S,V y S,V S3-2 15Cd 1/4W S3-3 75Cd 1/2W S3-4 75Cd 1/2W S3-5 95Cd 1/2W S,V V S,V y S,V y S,V y S,V S2-2 30Cd 1/4W S2-3 30Cd 1/4W S2-4 15Cd 1/4W S2-5 75Cd 1/2W S3-6 S3-7 S3-8 95Cd 95Cd 30Cd 1/2W 1/2W 1/4W EOL S2 S2-6 30Cd 1/4W EOL S3 S1-1 15Cd S1-2 15Cd S1-3 S1-4 15Cd 15Cd S1-5 15Cd TO EXISTING DATA LOOP 2------�� EXISTING TENANT J -BOX D,I '' D,I D.I 21 '' 21 21 S1-6 S1-7 15Cd 15Cd S1-8 S1-9 S1-10 15Cd 15Cd 15Cd S1-11 15Cd SINGLE LINE DIAGRAM S1-12 15Cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved z c z 6Q cc z r0 CO 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE m co (N1 co O zco o Q0) cco �0 w < a- W(D W zz JUw 0 cc =�cn_ W cc cow it H a W z J W .J z CO z 0 SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 06/26/19 BACKROUND PLAN PROVIDED BY: ,JOB NUMBER:38009-L1 SHEET FA -03 TO EXISTING TENANT JUNCTION BOX & NEW BPS BOOSTER POWER SUPPLY \ S,V s,v D FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED; BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. z ADJACENT TENANT SPACE N.I.C. LAYOUT POINT LAYOUT POINT EXIT HALL 111 I S3-1 15Cd 1/4W S3-2 15Cd 1/4W 6in_ '/////dB' ®!/////////////////////////// /////////////////////////dam//////////////////////////!///!//i // ///JU////////////////////.b' .®U/ =III1i' I I MN I BiM1 M 2 E rinki S1-2 15Cd MEN'S GUY'S #2 109 GUY'S 1 103 S3-8 30Cd 1/4W t PROCESSING BENC-- 17 /Alf L LOUNGE S,V 105 1 STOCKROOM 114 S3-6 95Cd 1 /2W S3-7 95Cd 1/2W 18 GIRL'S 1 104; S2-6 30Cd 1/4W GIRL'S #2 109= I I I I i % i//oiiA %'il/iii//i////l/////\�// /////ii: ///�//////////r///////.ri/////.e .s fir./ /%///////////zee/Ay M2 M2 S2-2 M2 M2 M2 S2-3 M2 30CdTTING S,V 30Cd FI 1/4W g 110 © 1/4W S1-11 r= .�-� ,., I I. j!F.R.'�'4' R 9PI ALCOVE I / 10 ., z: , .. t a., .mei ..: G1011 -17 L F %- I.!' (L1L 11.1_' �' LL. t' L !. i i S1-3 �- S1-4 � S1-5 � S1-6 � S1-7 � S1-8 � M 2 15Cd M 2 15Cd� 15Cd 15Cd 15Cd'a / M2 M2 M2 M2 / M2 f l/o////////////////�////%/%iv .r///I/////oo//////////////m////////////////////�/i/�/.///%/ //.�///////////////����/moo/// ////////////////�////////////.I./��///�/�//////���/i////.o.G;o,E', , %,, v //r //ofes _. - -. _ _ //o//i/fi//; ii ///iii�i//� S,V GIL BALL 5- LV1NG S1-9 m2 15C. G1 ADJACENT TENANT SPACE NJ.C. FLOOR PLAN - FIRE ALARM 6 EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE rn (0 N CO O 2aaaaa 0 0 LL SCALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 06/26/19 BACKROUND PLAN PROVIDED BY: ,OB NUMBER:38009-1j SHEET FA -04 NEW CEILING TILES AND GRID. NEW CEILING TILES AND GRID REFLECTED CEILING / LIGHTING PLAN 1/4" = 1'-0" • FlexHead Sprinkler Drop . l,:,%:� .. Cohugated stainless `%`'`'��,- steel hose • / ile in with stainless steel brai ViP Multi -Port Bracket • • • • • Adjustable Hub Flexheadr ommerdial Ceiling Unit l -Bar Ceiling Installation Model #2024,036,2048,2060,2072 RETAINER STRAP WHERE REQUIRED IN SEISHIC AREAS TOP DEAN/ C-CLAHP WITH SET SCREW 3/8' ALL. THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS ❑ Without Comments ❑ As Noted -i= t Rei' X. Per The Attacne. Letter These plans have been reviewed by The Tukwila Fire 1'revention Bureau fou conformance with current -City tandards. Acceptance is subje t to errors and omissions which do recti authorize ,-solations of adopted ttundards and ordirlences: The resporsibiliry for the .dequacy of de: i{: , ; Cts totally with the (3esigner.. ;Additions, deletions revisions to these drawings after this date will void c..._ acceptance and will require a. resubmittai of rev.,`,: d_awings for subsequent approval. Final accepta: is f:.-.7,10 ' to field test and Inspection by • The Tukwila Fire : ie.:.-.;.3i,rgau. Date: 7 - I • S(I Design per NFPA 13, Ordinary All materials to be new, U.L. listed, and M2 All fire sprinkler heads to remain unobstructed F.M.ed approved All heads to be at least 6' apart by lightings, ceilings, or any other means ®ss®siosw ssrassss PsassesCERTTIITIOrriPNCYFIRE PROTECTION SPRINKLER p 8 John J. Abel r �sCrotvn Fir , at b/mi/mitmifmmm slssssrsrsssssrj no. • 1 — Add Reliable Model G5-56 Standard Response 165° ° 4 —Relocate Reliable Model G5-56 Standard Res ons Concealed Pendents % x 1/2 o 1 — Plug existing p e 165° Concealed Pendents % x 1/2 (Flexhead s) a 5-575 O7 and i:va this Fire Permit No. /1/45--S - O7?-• i'or shut- down of approval. MALL SITE PLAN CROWN FIRE PROTECTION. INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Hollister Westfield Mall 857 Southcenter Mall Space 1440 Tukwila, WA PA 8 2015 - L �F�F P AP 2 TUKWIL 45-75" DATE: '-1 sL%o is DRAWN: cAl- SCALE: I 1 nC LLI � FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON P' Without Comments o As Noter: in Ree O Per The Atcacrie Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformance with current City - - ndards. Acceptance is sun}ed. to errors and 1nissions which do not authorize violations of adopted :�ndards and ordinnces. The responsibility for the 1equacy of design rests totally with the designer. .additions, deletions or revisions to these drawings after :his date will void this acceptance and will require a esubmittai of revised drawings for subsequent approval. sinal acceptance Is subject to field test and Inspection by the Tukwila Fire Prevention Bureau. Date: `S_ " /sem By: /411'N 51 i c:iva E.. : ;.� 1; THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' VIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-601Z —{ DEDICATED EUERCENCr FROM EXISTING MAIN FACP C CABLE C' CABLE 0 ujL Q N LO MOO U CI 0 PAD -3 00 INPUT INPUT TRS NAC1 NNC2 NNC3 NAC4 Aux 1+1- 1 2+2- 2 NC C NO + - + - + - + - + - 0 s e e o A 3.66 EOL 0 0 (-) (+) (-) (+) NAC S4 WAC S3 NAC S2 NAC S1 EXISTING POWER SUPPLY WIRING DETAIL COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING 0 HARD LID CEILING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE -(+ FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL 0 END OF LINE DEVICE(3,6K 1/4W) 0 SUPERVISED SWITCH GROUND N) 0 HTRI-R OSTATUS LED 0J 0 0 0 N.O. COM N.C. HARD LID SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V CABLE) 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. MUSIC (+) (-) STROBE SPEAKER (+) (-) 1+) ( ) STROBE (+) ( ) STROBE SPEAKER (+) (-) n 4 -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4.OA @ 125VAC) (4.0A @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL SPEAKER STROBES & STROBES ONLY WIRING DETAIL FROM PREVIOUS ADDRESSABLE 2 DEVICE 2 TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS HFP-11 TB1 @®®() Y Y O 00 NO COM NC 2 TO FAN SHUTDOWN EOLR 470 HTRI-M RED BLK ORG ORG GRN + TO NEXT a _ ) ADDRESSABLE DEVICE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL DUCT DETECTOR/HTRI-M MODULE/TSM-1 SWITCH WIRING DETAIL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN¢ TEMPERA RE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-9333% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > DEVICE IS USIED FOR AIR VOLOCITY APPUCAIIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION 1IMMTH DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 / STANDARDOKE SM DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT 0 0 0 0 > TO NEXT ADDRESSABLE DEVICE TO NEXT DEVICE CADDY BAR �l �f SMOKE DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2015 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS r T Z co O w ,- Vg p �Z W d Jo I- W CZ JU)wC�C OJ�z� w W = LI- 0I_ I` co CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/23/15 BACKROUND PLAN PROVIDED BY: 10B NUMBER:12021-1J SHEET i SWITCH + — INPUT LED TSM -1 HTRI-M RED BLK ORG ORG GRN + TO NEXT a _ ) ADDRESSABLE DEVICE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL DUCT DETECTOR/HTRI-M MODULE/TSM-1 SWITCH WIRING DETAIL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN¢ TEMPERA RE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-9333% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > DEVICE IS USIED FOR AIR VOLOCITY APPUCAIIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION 1IMMTH DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 / STANDARDOKE SM DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT 0 0 0 0 > TO NEXT ADDRESSABLE DEVICE TO NEXT DEVICE CADDY BAR �l �f SMOKE DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2015 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS r T Z co O w ,- Vg p �Z W d Jo I- W CZ JU)wC�C OJ�z� w W = LI- 0I_ I` co CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/23/15 BACKROUND PLAN PROVIDED BY: 10B NUMBER:12021-1J SHEET i A B FIRE ALARM BOOSTER POWER SUPPLY BATTERY Project: HOLLISTER CALCULATION Alarm (mA) Total Alarm Panel: EXISTING BPS PAD -3 Date: April 24, 2015 Module/Device BOOSTER Qty POWER Standby (mA) SUPPLY Total Standby (mA) (mA) Power Module 1 30 30 0 30 30 0 TOTAL FIRE ALARM POWER SUPPLY 30 30 Auxiliary Device Current 0 0 C ' D E F G H I J K Notification Appliance Load (Max. Total / mA) 0 5711 Total A = ' 30 i Total B = 5741 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 30 5741 Total current ratings converted to amperes (line D x .001) 0.03 5.741 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.72 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.4782253 Add lines G and I Total Standby and Alarm AH 1.1982253 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 1.43787036- 12 V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 PROJECT: HOLLISTER Panel: EXISTING BPS PAD -3 POWER SUPPLY Date: April 24, 2015 Notification Appliance Circuit Detail Wire Resistance 2.58 CURRENT TOTAL= 5711.00 1 SET -IAC @15cd NEW 3 5 SET -MC @30cd EX SET -IAC @75cd EX SET -IAC -CW @95cd SET-IAC@l5cd EX ZR -MC -CW @30cd DEVICES 11 69' 111 200: 64' 11 TOTAL mA=, Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) r • EOL Volta 69' 222 600 0 320: 0 1211; 14 350 21.81 1211 (WL*2)*(Rift); 1.81 otal Cot Load) 1.21 = I * R) 2.19 21.81 SET -MC -CW @15cd 69 i 0; SET -MC -CW @30cd 1 SET -IAC -CW @75cd 200: 0 SET -MC -CW: @95ed 264 ZR-MC-CW©15cd 69 0 ZR-MC-CW @3Ocd .,- ' 111 0 TOTAL mA= 1500: 14... 24.00 DEVICES 0 :Total Wire Resistance (R)) 7otat l evice'Load, Amps (I) Voltage Drop (E ) EOL Voltage 1500 WL*2)*(Rift) otai Cct Load} l(E=I*R) :4-E) 0.00 50 0.00 24:00 DEVICES SET -MC -C SET MC -CW -@30c SET -MC -CW @75cd 200: SET -MC -CW @95cd SET -1/1C -VV 6110cd M -ZR -MC -CW 3ocd 0 TOTAL mA=: 1500: 14 ;Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E EDL Voltage (WL*2)*(Rift)! li Cot Load) E= I * R) 24 E 1500 0.00 1.50 0.00 24:00 DEVICES SET -MC -CW @15cd 69 0 SET -MC -CW @3Ocd 1 SET -MC -CW @75cd 200: 0 • SET -MC -CW @95cd 264 SET -MC -W @110cd ZR -MC -CW tcii30cd 0 233: 111 TOTAL mA 0! 1500; 14 24.001 1500 Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage CALCULATIONS (WL*2)*(Rift): (Total pet Load) I(E=1*R) 24-E) 0.00 1.50 0.00 24.00 TO OTHER EXISTING , NAC DEVICES TO OTHER EXISTING NAC DEVICES S,V 75cd SINGLE LINE DIAGRAM 15cd 75cd FIRE ALARM NOTE: ALL SPEAKERS TAP TO 70 -VOLTS 1/2 -WATT. t) ao 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 0 T Z loo OW SS I_ Q rn I owQ W d J O ~ W ¢Z Jcow< Qacz. = Dog W CC D L- OI— i` U) co �CALE: NOT 0 0 W z W J 0 01) C!,) Z 0 U U DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/23/15 BACKROUND PLAN PROVIDED BY: .OB NUMBER:12021-1i Proprietary and Confidential, Copyright 2015 by Guardian Security Systems, Inc. All Rights Reserved \ SHEET FA -03 EM (E) EM TO OTHER EXISTING NAC.. DEVICES SV EX �- A-23 75cd o-S,V EM (E) 15cd EM (t) • S,V ll 1 1 1 1 ,1 (R) TO OTHER EXISTING NAC DEVICES S EX 75cd EM (E) EM i EM (RT\ ENt ITYJf . (E) 5 EM (R) A-1 (TIE) 1' 1 FIRE ALARM SYSTEM PLAN SCALE: 1/4" = 1'0" FIRE ALARM NOTE: ALL SPEAKERS TAP TO 70 -VOLTS 1/2 -WATT. ELECTRICAL PANELS AREA OF WORK KEY PLAN SCALE: N.T.S. Proprietary and Confidential, Copyright 2015 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 1 DMG I DESCRIPTION SHOP DRAWINGS DATE 04/23/15 2 CCCCC 0. O zoo �- O w7""" CCta (I) W < Jo Ns L_ C J� V w aC C O �z� C Cwj g cCw F- CC I -01— I` co W cr -CALF: AS NOTED DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/23/15 BACKROUND PLAN PROVIDED BY: SOB NUMBER: 12021-12 SHEET FA -04 FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYTEM FA -04 SITE PLAN, SYSTEM CALCULATIONS (GENERAL), RISER DIAGRAM WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR #16 FPL/FPLR RED (JACKET). V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED .#18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS : AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2' 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY. HAVING JURISDICTION. 5.. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. DETECTORS SHALL .NOT BE MOUNTED IN DIRECT - AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO. CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN. ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR 'ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10: THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH. ARTICLE 725 AND 760 OF., NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE. TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUVTED: AT A HEIGHT OF 80" A.F.F. OR 6". BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL. PANEL NUMBERS AND CIRCUITS WILL BE QN THE RECORD .DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15:: PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES: SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE 'ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. i 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2002 6.4.2.2.2 ALL STYLES OF CLASS, A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2002 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS -305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 1 1 6 11 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARAI FIRE ALARM SDD-C SIEMENS REMOTE ANNUNCIATOR PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP ® INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D I DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD 111 CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD ISN LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD ® SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP. W/ .1 G RING CEILING DUCT SMOKE ®D. DETECTOR AD2-XHR W/ SIEMENS HFP-11 DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING 2cC FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING FIRE ALARM SPEAKER . STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1 /2" EXT. 80" A.F.F. TO BOTTOM c FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U_0_N. Q C FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX W/ 1-1 /2" EXT. 80" A.F.F. TO BOTTOM FIRE ALARM B p STROBE WP (WEATHERPROOF) SET -S17 -WP " SIEMENS MT -SUR -BOX 2" PIPE VERIFY IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FATC FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A. N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A Wthout Comments As Noted in Red Per The Attached Letter I nese plans have )lien reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceprance is vuniect to errors and omissions which du not authorize violations of adopted standards and or -at -lances. The rr~;'cnsibR :,vforthe r adequc':y O` CI; tOt.E`t; ;y .; r , !he designer. .,:finer. drawings atter ti 7 „ :i U require a r �u rtll't�i of r evil G; .;'!1!i:y5 to cubbequent approval. ;neJ ac'v%p iar tce i:.,ubject to fic !d test and inspection by The Tu'rwila Fire Pi evention Bureau. IDate: y �� By: GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A TUKWILA FIRE DEPARTMEn Please call: 575.440Z and give this job No. OY-F-/0c1 and exact address for shut' ouwn or restoration approve; NOTICE A otnp°ems, signed, Tukvviia Fire Department Pre-test Certificate must be presenter! to the Inspector prior to commencement of Acceptance. Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. -Ztis�w�l Ioc,k o A• ded; 44441 FA -5Y) .- Syy •�. #u cok.PI)/ 'u(. Mr -PA 72- �.o0eal -1-, Copyright 2006 by Guardian Security PA I - 2008 Tukwila Fire 7-25-21 72/ Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS r m LU DESCRIPTION 0 0 2 C �CALE: 1/8" = 1 DRAWN BY:.': (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/19/08 BACKROUNDPLAN PROVIDED BY: ,OB NUMBER: SHEET A-01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTAL_ LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AIR DUCT 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT pat SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE`—/ o END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH GROUND 0 0 —0 © © HTRI–R STATUS LED CO DUCT DETECTOR LOCATION N.O. I` 0 cD 0 CDM N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 0 TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCAB (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE L - + NOTE 1; VOLTAGE MAX. - CURRENT MAX. - CONT. RES: MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD)- MAX. LINE SIZE- i MIN. LINE SIZE - MUSIC OUTLET SAMPLING- •\ TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE LII -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE I DEVICE LOOP .I 0 `FROM'; SLS CONTROL PANEL OR 01> 1 PREVIOUS ADDRESSABLE DEVICE (-)> TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE (-) , FROM XLS CONTROL PANEL OR {(¢) PREVIOUS ADDRESSABLE DEVICE (-) RELAY CONTACTS (4.DA a 125VAC) (4.0A a 30VDC) 27 VDC 3.5 mA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF . 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. TB1 L�0000 .2-3.4.5 6 HCP TB2 00 65 END OF LINE M DEVICE 7 D 0 (3.6K 1/4W) SUPERVISED 1 SWITCH GROUND / / / 0 0 © 0 HTRI–D STATUS LED 00 0` NOT USED 0 END OF LINE DEVICE 0 . 3.6K 1/4W) 0 NOTE:. FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL WEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) - 0 GND N AC DIDID 0000 U n 0 PAD -3 0 0 O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1-- 1 2+.2— 2 NC C NO .+ .— + . —-- 111 PI DJ 11111M 11113211341113011m 24K TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE SUPERVISED "WITCH NAC -4 NAC -3 NAC -2 NAC -1 470 OHMS iW EOL 0 p 0 INPU (4) sI TS ca M-1 0 as gel o~ LRN 1.6 z g ONO gc°' m00 0 L2 3A 5_. WSW TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL FROM REMOTE POWER SUPPLY ('S' CABLE) FRI FACP (VOICE CIRCUIT) C'V' CABLE) SCIE: NONE EARTH GROUND _>(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE C (STROBE) SPEAKER O ) STROBE C'•� (+) (-) STROBE SPEAKER SPEAKER/STROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY R E BO- 4S 'DEEP. BOX W/ 1-1/2- EXTENSION RING' (SPEAKER STROBE) 4S BDX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALEJONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NO1E: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN 1 RA +32' F (0.0 TO 100' F C .) UMIDITY; 00-- X RELATIVE HUMI TY. NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POKER SOURCE DATA IN (-) >— DATA IN (+) > MACE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FTAIN *JEN USED IN CONa1NC11ON 1M11 DUCT HOUSINGS AD -11P OR AD-11XPR _.....____.s...\.\\s.\\ Lt BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL IABB. SCALE ( ) DA (+) DATA OUT TO NEXT DEVICE > DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID --- CEILING HARD LID -_\ SPEAKER SUPPORT T`E BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION N. CEILING MOUNTED -- SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTI❑N BOX - MOUNTED ON CEILING FLEX \ JUNCTION BOX -- --t MOUNTED AGAINST CEILING SUPPORT II O 0 TO NEXT DEVICE O O CADDY BAR SMOKE DETECTOR—' SMOKE DETECTOR MOUNTING SCALE=NONE ri • ht 2006 b Guardian Securit '--- SUSPENDED ILLUMINATED CEILING S stems, Inc. All R. • hts Reserved 743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS LU DESCRIPTION LU F- 1 co co ccO) w <0 W - U)�wz cc W Q o 5' 0 1-12E- - �o5 LC) a0 i -- /SCALE:1 /8"=1 DRAWN" BY: (-ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/19/08 BACKROUND PLAN PROVIDED BY: �OB NUMBER: SHEET FA -02 r 0 pci _11 -av,as- hi 2S 15 2S I. BPS • 2S,2V —1= i=1 El 0 30 El 0 30 15 Cu ---------- -----_-_-_-_-__ ---------- ____ ---- S,2V 2V,S ----- ----- i • C) 2V,2S • • E. CU 5 Cu 30 11 TIT S2V,2 30 II Jq_ 2V,2S 30 EOL Si 11: I _I_ Li. „Lr, El 0 30 El 0 30 ,,,, rp:-_---._ -__--- ____,. c•-.; \ \ 1 11 C 1 t. \ I , 0.----1 ; ..-- 1.------- 1.------ :1Er iL -I \ ; : • : 15 NORTH HOLLISTER WESTFIELD SOUTHCENTER MALL SCALE 1113'Ll' ;1: • FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND. MUSIC INTERFACE. FIELD LOCATE SIEMANS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDLINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR, WIRED. BY ELECTRICAL CONTRACTOR. 1 Corwriaht 2006 by Guardian SecuritY Systems, Inc. All Rights Reserved• SCALE: 1 /8 =1, DRAWK! BY: LANDERSON DESIGNED BY: R.VEZZANI DATE: 3/i-9/08 BACKROBNB, FLAN PROVIDED BY: f . bE ; ----- EC] Y� 1465 I 1150 J uil 1 KIDS FOOTLOCKER 112001 U7 1430 I LL.0 '."1 N H (I I'3 14_ ;`- 11490.1 RE;.rL:p;r STSR;;E NORTH R:SFR ROOM ; i:'I'JP uOCK LJ rTh rn [1 ,r LL LL LSI 1215 r; 12,n 141 CI-I_ESE(:'.,,?\'__ TlACTOR `•`. R3__1 I HOLLISTER WESTFIELD SOUTHCENTER MALL ---- SCALE 1132'4 IA t F0011 OCS: ER U rT 23 ::n 0 (._;ALIF OP,NiA MAC GRILL EOL S2 v,s FA JBOX BPS 13,P 120 VAC FLOOR 1 v,s v,s O v,s © v,s O . v,s v,S 15 15 15 30 15 30 30 30 EOL Si :=LECTRI G!' Ll( sr},1 .. PIZZA KITCHEN 0,�' CO?,IPACTO <7 n SYSTEM CALCULATIONS HOLLISTER HOLLISTER FACP ADD ONS Current Load: SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations Standby: Alarm: Current Load: Device Type HFP-11 AD2-P Qty 6 Standby: Alarm: Amps 0.0022 Total 0.0022 Amps 0.0023 Total Device Type Qty Amps Total 0.014 Amps Total 0.0635 0.0635 0.064 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R HTRI-D 1 0.009600 0.0096 0.021 0.021 0.001600 0.0035 0.0731 Amps 0.021 SET -MC @15CD SET -MC @30CD SET -MC @75CD SET -MC @110CD ZR -MC -616-63- 214-mc 15CDZR-MC @30CD Amps HCP Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours 4 0.064 0.256 9 0.098 0.882 0.175 0.233 2 0.064 0.128 0.098 1 0.0015 0.002 0.03 Amps 1.2975 Amps Alarm Current Load: 0.021 Amps For 5 Minutes= 0.002 Amp -hours 25% Derating= 2.195 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.2975 Amps For 5 Minutes= 0.109 Amp -hours H Total System Current Load: 2.195 Amp -hours Battery Pair to bdi sed: 12VDC Amp -hours 7AH 25% Derating= 1.036 Amp -hours Battery Pair to be Used: Total System Current Load: 12VDC 1.036 Amp -hours Amp -hours 7AH xx>rfx RECOMMENDED MINIMUM BATTERY SIZE = 7.00 AriperexHours BATTERY SIZING CALCULATION Notification Appliance Circuit Detai% PROJECT: WESTFIELD SOUTHCENTER MALL Panel: HOLLISTER ' y Date: !April 3, 2008 CIRCUIT:: S1 ; t QTY }- Device Type (Alarm Current? Alarm Total Wire Size ? Wire Length 2 ISET-MC @15CD - I 641 128•1 Wire Resistance 3.24 CURRENT TOTAL= 1266 4 i SET -MC @30CD 981 392 O {SET -MC @75CD - 175i 0 233; O 1SET-MC @110CD - 2 = ZR -MC @15CD _. _ 1 128, • O ]ZR -MC @75CD. 175 0; i . O ZR -MC @110CD 2331 01 _.__ 0f Voltage at EOL Circuit Total ; yTotal Wire Resistance (R) ? 1.83! (WL w 2) (R/ft) • I Total Device Load, Amps (I) 1 0.65; i (Total Cot Load) -. 1 -- 'Voltage Drop (E) �- # (E=.I"'R) I • ; IEOL-Voltage . (20.4 E) DEVICES=i8 TOTAL mA-i 648 •.___ r. 12 1 282 i 19.215870721 648( ;CIRCUIT: • ; S2 i { ' QTY Device Type [Alarm Current, Alarm Total ; Wire Size 1 Wire Length ' Volta a at EOL t_Circuit Total # i 2 ?SET -MC 15CD 9 i 9 ._ 64 : 128 i I 5 SET-MC©30CD 490' I 0 16E. -MC @75CD ! o1 981 175i 233; O 64? O' 98; 0 175.s 0; ' 233! ..__.__. 0 t ; 0 ;S O ET-MC(_cD1 1 OCD , O --jZR-MC @15CC - ZR -MC @30CD 'ZR -MC @75CD O i ZR-MC©110CD 0 0 0 DEVICES={7 I TOTAL mA=j 618; 1 1.18; 19.22 t Total Wire Resistance (R) i 2.401 - _ . ( WL W 2 )/ (R/ft) ,Total Device Load, Amps (1) (Total_ Cct Load) IVoltage Drop (E ) (E= I " R) =EOL Voltage (20.4-E) 18.918283 1 6181 notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: HOLLISTER Date: April 3, 2008 Wire Resistance : 5:16 CURRENT TOTAL=; 27 CIRCUIT:!SPEAKER CIRCUIT QTY : Device Type #Alarm Current? Aiami Total Wire Size ` Wire Length -15 i70.7V1/8 ,_1 1.8 . 271 0 0 . DEVICES= 15 I 0. 0 01 �I TOTAL m A-- 01 0 01 01 27 12 1 � Voltage at EOL 1 Circuit Total r "Total Wire Resistance .(R) (WL*2)*(R/ft) - -;Total Device Load, Amps (I) (Total CO Load) VoltageDrop(,EY)� }EOL Voltage ' (20.4 - E) I s 570 ' 120.24117521 27 } 0.62 1.48 18.92; - 0.031 0.16 20.24 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 LLJ LU LIJ CO CI 0 LLI Ct 25 REVISONS LLI 0 co a, F=E6 CO 2 [L-1- f- lu] ffC LU LL DESIGNED BY: BACKROUND PLAN PROVIDED BY RISER DIAG SYSTEM CALCULATIONS Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER: SHEET FA -04 GENERAL LEGEND —P -4 O BOD BOB BOJ FOS FOW EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPUNG ( UNLESS NOTED ) CAP PLUG CENTERLINE HYDRAULIC REFERENCE POINT CENTERUNE PIPE TO BOTTOM OF DECK CENTERLINE PIPE TO BOTTOM OF BEAM CENTERLINE PIPE TO BOTTOM OF JOIST FACE OF STUD FACE OF WALL FOC AFF CH R.C. 4 E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR CEILING HEIGHT REDUCING COUPLING OUTLET COUPLING WELDED OUTLET 'AT" FITTING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALSO "Gr) THREAD/` 1T" (ALSO "Fir) ALL -THREAD ROD 10 :h9 8 Q/ F1/_ •elea Teeing uonueneid eJld eIIM){nI Gq t hq uol;oedsul pue peg o;;oo[gns sI eoue.daooe feu!_ •IenoJdde;uenbasgns Jo; s6u!melp paslnaJ;o Iel1!wgr.F- e aJ!nbai IIIM pug; aoueideooe s,(Ia pion fl;;r•, Jape s6ultre!p esaq; 04 suo!SIAOJ JO SOOF4010p •Jeu6isep ag; g11M Allem STsei ubisep eq; Jo; AImisuodsoi e41 •saauzu,oJo pue solEoue pa;dope;o suogeloin ezuoglne;ou op goiquat suolsslw pue SJOJJe o; Ice!tinQ sl eoue}deoov •spJepue; Apo luau= g;IM eOU WJJOtUO3 J0; neaJfH uol;uenaJd eJld eIW, Inl eql Aq paMalnei ueeq eneq sueld eseu I .>a1;al pegoelld 041 Jed pOH III Pe1eN eV sluau)Wo3;noq; ORL WERIF THIN 2111,4 III, J. ass I■ mroo#,T 'WNW 1 I 1 U tn 0 I 0 U FIRE PROTECTION NOTES FIRE SPRINKLER SYSTEM TO PROVIDE 100% SPRINKLER COVERAGE IN ALL AREAS PER THE STATE AND LOCAL FIRE MARSHALL WHENEVER POSSIBLE AUGN SPRINKLER HEADS WITH UGHT FIXTURES, AIR DEVICES AND TO CENTER OF 11LE. THE PATTERN IN EACH ROOM SHALL BE CONSIDERED INDEPENDENT OF OTHER ROOMS. ROUTE ALL PIPING AROUND ELECTRICAL PANELS. COORDINATE WITH ELECTRICAL CONTRACTOR. PROVIDE SPRINKLER HEADS GUARDS IN ALL LOCATIONS SUBJECT TO DAMAGE. FABRICATION, ERECTION AND TESTING OF AL PIPING SYSTEMS SHALL BE IN ACCORDANCE WITH OWNERS GENERAL REQUIREMENTS, N.F.P.A. #13, 24, 231 & 231C. AND LOCAL CODE & AUTHORITIES. SPRINKLER PIPES FEEDING COVERAGE BELOW STORAGE DECKS ARE TO BE FED BY ROUTHING ONES DOWN FULL HEIGHT WALLS AROUND PERIMETER OF DECK. FULL OPEN CLEARANCE OF STORAGE DECK IS TO BE MAINTAINED. rREMOTE AREA ORDINARY HAZARD GP 2 20 / 1500 S.F. J BASE OF RISER: 92.82 PSI / 504.2 GPM TUKWILA FIRE DEPARTMENT Please call: 575.4407 and give this job No, 02-S-07 Co 4, - and exact address for shuts down or restoration approval: MOTXCE Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic test approval. 0•X24• LANDLORD PLY AIR DUCT imirimimin 1 1' 1 Mill 0 ,tmiiiitttttt.ri,a"ttttr_ Ir--..f1i laillidelI '�a 1_�w�� jll.I EE11L:l �I�IIMID,, �w�1� I 'i■`ii ,� ■iL•1rr,.I� -;t■:■W„ 1�1= n r rm. ► -• _- -. ��I��Ifi I - IIE+. ■N�:. i 9 Iv IMMIllid _�I_IIu11EIifl -_ �r IEEiItI�s1■ i1i>i 111 ' $1111111111111111M111111111111ffiliti�C► , II cum I �lI■�7IIIm U v � IIID iftrirmumilliMINIIIIIMII111111111111•111111111111 oil i�. �'5iciammiiIiw �>1CD��imire Mair- I :11710v.ormilumniornomillii,�' " E■1111r 1111111. ��i POIDE7 ET: -11PriX1 I aiiil 11111/ 1►:1-a11n I I I Ma i ■!IEC EIII1111$,I • , u�IB- 1„• t•m �iwtt:] �■i ,:I lei :..MOD �I ,Jl.MEMEMI_t11 J55 ���!►I,.. lfs:o. till I wi�i I■�w■1,_=I or tzl11111/ . Ir r ■s ■�Illl Ir..'.Mag14 MINIM lit...1111MI OM Ipf� ���I � i� ��_IIr ai=F!'IllisiI IillliniimilliI.Iiiiiiiiiiii''Ir, .,� iiailr � c fir! � ,r . !moi 11l A1P11 INN= 3�tl�:� � --.::--= Y�_ ji.� ..�■eN■rvw�ii �":�� !; ��r �. ■I!,4 it IE.� Q,IZ IMMI t x��0 4, 11111111111111011111111,1111011_ IIPPINE_IPUUUUU ra ,EEEEEE1111 Illi EE 11�i � 11. l ill I'����niiisiiiiiampqmomm III 11 'lea 111111110011E01111E131 �fiii�� �t����..-is>_rtw��t►vtc:�.ar�� IIiI 1 . ��E� EwE11111111E1EEEEEI 11!`”: "'re,MI ss>17741,1I �L a�L��1��EryiWJ����. --. i E 1E..... 9112 E12EIi 1r��c I `, •,...,....,.........„- i ....`..�■I.rn...- •I171:�; t I............,.. IEEE ilI inteJ IIIIEEEEI�bilimiii )111.171■, . .>�W� ��1E'9IL � :soma I�1�1I1��1,�-'1iiI I R UIi iit_I ILIIRIL U1t 11tiIii iiik iiiI i #mI _ ES.. iE_iIEIENEil■�i 1 �.•_ �j EI z--� ...I�Dhir'r'' Irma. luiliK AMIE `hall` all 1411117 .ter re i t y4 4r:.. -II- gigN �ttc �.._. �i1i� �i9I 370 D:I� . IlliiiiiiiiiRligliriNg 'I'm 11111111111111111111111111111111111111111111111111 'I IlliiilliciiiInfill'i �EEEIIISErIIrEEUIIII i . i dUihnimo.•..J U .... uit •TIE �• P ��, ���� . [!�:d�. , ;ter. ; ? ; �� �t ' 1111 Jam _ flu... g airsummiza iii ll c icii i VAIN IN UI nsinai s �11� � �1 ..� >�m71ErI�LvI Ii .... == i'I--.L,■.,!!!P��IO1i--I■__�••I. mI 7I■�■•aimini meIg- -H ■ .' ✓.' ._...«_..._ raF+," ...1` i 5 ✓ '�:/ F d.. .'r/✓{ 13 M ! a § ✓.. Y A:.. H v+f MEM Fill® Mir IIEE� Al L I'll !�I•��i.li#1tL� IM EEE �.a�zrry iiiiallitmri _Wit i! i ii I rivral=mmromn..11 lnainiEi��,_t ®i -®� I 1�20-XI6 LAND �'"��IIII1111 W V iIIII __ .4 _ :-rev ,r�-_ 111 �'4„ 10 :. �I1�r7I• f0 4 ,,, iii- `" ki ma .: 0.0 �� �m `— I ai " ��� �� �i'NI�{moi_- MIMIOUNWIMMIIMANZWYINIMIK=OMMilIMigli 1D ,�. ,D1 �,� III 71�t:..� Mom �� YF•�11�I,��e�� 1� �i.►� ��a►�®i --- &Lei 1�J ����i �� I��l.ir 141. ®L>��_.© _ ' _ l I®mummuiew.-•r-,Mwur�ilri.�.sL__ 4 I +��ri..rur.: . w[�l--_-.��i..���rTL. - c�._n�!�►z E�r 1111MMI Nei E) 20"X20" LANDLORD EXHAUST DUCT (E)94•X20• LANDLORD SUPPLY AIR DUCT -10 P/P/NG LEGEND IIMMINEMP - - -0- EXISTING PIPING NEW PIPING TENANT SPRINKLER PLAN K:::;;77 SCALE: 1/4" = 1'-0" t DESIGN CRITERIA DESIGN AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE LOCAL BUILDING CODE, N.F.P.A. 13 (1999 EDITION), AND ALL AUTHORITIES HAVING JURISDICTION. ORDINARY HAZARD (GROUP 2) AREAS: DENSITY: DESIGN AREA: MAX SPRINKLER COVERAGE: HOSE DEMAND: DURATION: 0.20 GPM/SQ.FT MOST DEMANDING 1500 SQ. FT. 130 SQ. FT./HEAD 250 GPM 60 MINUTES SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS" 1. "SALES" AREA SPRINKLER HEADS ARE TO BE FLAT OR MATTE BLACK SEMI -RECESSED HEADS WITH FLAT OR MATTE BLACK ESCUTCHEON. BASED ON RELIABLE AND ALTERNATE MAY BE VIKING OR GRINNELL AND MUST BE APPROVED BY THE HOWSTER CONSTRUCTION MANAGER PRIOR TO ORDERING AND ANY INSTALLATIONS. ALL EXPOSED PIPING SHALL BE PAINTED BROWN IN COLOR AND MUST BE COORDINATED WITH ALL TRADES. 2. "PORCH" AREA SPRINKLER HEADS ARE TO BE FLAT OR MATTE BLACK SEMI -RECESSED HEADS WITH FLAT OR MATE BLACK ESCUTCHEON. BASE BID TO BE RELIABLE MODEL OR EQUAL 3. 'NON -SALES" AREA SPRINKLER HEADS ARE TO BE WHITE CONCEALED HEADS WITH WHITE ESCUTCHEON. BASED ON RELIABLE AND ALTERNATE MAY BE VIKING OR GRINNELL. 4. "NON -SALES" OFFICE AND LAVATORY AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE. 5. 'MALL BULKHEAD' AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE. THE DESIGN INTENT IN THE RETAIL STORE AREAS IS TO INSTALL THE SPRINKLERS CENTERED BETWEEN THE BATTENS MOUNTED ON THE CEIUNG. PROVIDE SPRINKLER HEADS (UP RIGHT) ABOVE NE CEIUNG IN CONCEALED SPACES HAVING EXPOSED COMBUSTIBLE CONSTRUCTION. GENERAL NOTES SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 - 2007 ED . ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS ORDINARY HAZARD OCCUPANCY: 130 S.F. PER SPRINKLER MAX CALCULATED .20 / 1500 S.F - ORDINARY HAZARD GP 2. NEW PIPING TO BE 'DYNA-THREAD' THREADABLE THINWALL OVERSIZED SPRINKLER ESCUTCHEONS PROVIDED AT SPRINKLER CEILING PENETRATIONS PER IBC/ASCE 7 GENERAL NOTES ALL ABOVE GROUND FIRE PROTECTION SYSTEMS SHALL BE HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HOURS YAM NO VISIBLE LEAKAGE. ALL CONCEALED PIPING SHALL BE AIR TESTED, WITH NO LEAKAGE, PRIOR TO F1WNG SYSTEM WITH WATER. THE FIRE PROTECTION CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AUTHORITIES HAVING JURISDICTION 24 HOURS PRIOR TO THE TEST. THE ENGINEER SHALL WITNESS ALL TESTS. THE FIRE SPRINKLER SYSTEM SHALL BE SUPERVISED BY AN APPROVED CENTRAL STATION, PROPRIETARY STATION, OR REMOTE STATION MONITORING SYSTEM IN ACCORDANCE WITH N.F.P.A. 72, AND LOCAL AUTHORITY HAVING JURISDICTION. by others THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE WIRING OF ALL ELECTRICAL FIRE PROTECTION DEVICES AND EQUIPMENT WITH THE ELECTRICAL AND/OR FIRE ALARM CONTRACTOR. ALL FIRE ALARM WIRING BY ELECTRICAL CONTRACTOR. ALL DEVICES SHALL BE FURNISHED AND INSTALLED BY THE FIRE PROTECTION CONTRACTOR. THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE THE LAYOUT OF THE FIRE PROTECTION SYSTEM WITH ALL TRADES AND ARCHITECTURAL REFELECTED CEILING PLAN PRIOR TO INSTALLATION. THE FIRE PROTECTION CONTRACTOR SHALL CENTER (WITHIN 1") ALL PENDENT SPRINKLER HEADS INSTALLLED IN ACOUSTICAL LAY -IN CEIUNG TILES. ALL PENDANT SPRINKLER HEADS IN CEIUNGS SHALL BE SYMMETRICAL WITH UGHTING AND AIR DEVICES. SPRINKLER HEADS ARE REQUIRED ABOVE THE CEIUNG IN ALL AREAS OF CONCEALED SPACES. THE LOCATION OF EXTERIOR FIRE PROTECTION EQUIPMENT SUCH AS FIRE DEPARTMENT CONNECTIONS, TEST DRAINS, ETC., SHALL BE COORDINATED WITH THE ASSOCIATE ARCHITECT AND APPROVED BY THE LOCAL FIRE DEPARTMENT. FINAL APPROVAL IS SUBJECT TO ACCEPTANCE AND TESTING BY ALL AUTHORI11T1ES HAVING JURISDICTION. CONTRACTOR SHALL SEAL ALL PENETRATIONS OF FIRE RATED ASSEMBLIES (WALLS, FLOORS, ETC.) AS REQUIRED TO MAINTAIN SASSEMBLY RATING. REFER TO ARCHITECTURAL PLANS FOR FIRE RATINGS. MALL LOCATION PLAN ROM Macy; e. -rte- A s • vV• Hollister SPACE /1440 LEVEL 1 OF 3 Wi T IE ALIGN SPRINKLER HEADS IN UGHTNG GRID WHERE EVER POSSIBLE TYPICAL THROUGHOUT SPACE A 3-12-08 REVISE PER TUAZON ENGINEERING REVIEW OF 2-11-08 FILE COPY PROJECT TOTAL: 92 A COWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669. HOLLISTER Co. P AY Level 1 Store # 603 / Space #1440 Tukwila, WA 90025 DATE: 03/08 DRAWN: C.A. SCALE: NOTED 1 OF 1 U FIRE PROTECTION LEGEND D SYMBOL DESCRIPTION SPRINKLER SIN QTY 0 BLACK PENDANT TYPE HEAD W/ BLACK ESCUTCHEON RELIABLE Fl -FR Q.R. BLACK PENDENT 1/2' 155' W/ BLACK 1 -PC CANOPY R3615 2 O j . BLACK FULLY CONCEALED HEAD W/ BLACK ESCUTCHEON FOR THE SALES FLOOR RELIABLE G4A Q.R. CONCEALED PENDENT 1/2" 155' W/ BLACK COVER PLATE R5415 51 ® WHITE FULLY CONCEALED HEAD W/ WHITE ESCUTCHEONW/ RELIABLE G4A Q.R. CONCEALED PENDENT 1/2" 155' WHITE COVER PLATE R5415 39 ALIGN SPRINKLER HEADS IN UGHTNG GRID WHERE EVER POSSIBLE TYPICAL THROUGHOUT SPACE A 3-12-08 REVISE PER TUAZON ENGINEERING REVIEW OF 2-11-08 FILE COPY PROJECT TOTAL: 92 A COWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669. HOLLISTER Co. P AY Level 1 Store # 603 / Space #1440 Tukwila, WA 90025 DATE: 03/08 DRAWN: C.A. SCALE: NOTED 1 OF 1 U 857 SOUTHCENTER MALL ASSOCIATED PERMITS 19-F-154 19-F-137 08-F-109 19-S-178 19-S-143 15-S-075 15-S-072 15-S-062 08-S-076 410444 4tt CITY OF TUIKW LA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted fir plan review: **PLEASE PRINT** SITE LOCATION Site Address: O.; 7 SoViiic-eji-Ie ^ Y 7 t I I Tenant Name: \\O 11\ ' ( King Co. Assessor's Tax No_:/ Suite Number: WOO Floor: New Tenant? D- Yes - No Property Owner's Name: WP-'\--ct2 x Y 1/ m_ m� Mailing Address: CONTACT PERSON -if there are questions abort the submittal. city - State Zip Name: • kccARd o1 or) Day : Li 2 J 7f U! / Company Name: C find Mailing Address: VO t2.\ \ D X111 C e�2., UDt\ '1 SOtZ Fax Number: E-mail Address: 3e SS'C ef2)Yb NICET III number g7q L% • �Qq ms s of Tukwila 1 �� Business License number. la� • Osla S 4si Z Total number of newhelocated devices or sprinkler beads: 76" Valuation of Project (contractor's bid price): $ F5i cnn Scope of Work (please provide detailed information): _ . tCa' LIB /�. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of coasction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid rmless�the work on the site authorized by such permit is coed within 180 days ager its issuance,,or ifthe wart: authorized undue site by such pean& is suspended or abandoned fora period of 180 {lays aper the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, fir periods not more than 180 days each. The extension shall be requested in writing and justifiable cause gyrated. I HEREBY CERTIFY THAT I HAVE REP 4ND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE ORtN' AND i AM AUTHORIZED TO APPLY FOR THIS PERMIT. •t. S BUILDING OWNER OR AVM Signature- Print iC‘X -1�6fD)YECY 1 Da ', one: 731// .7W09' Plan Permit App.doc JUL9 2019 TUKWILA FIRE paw: 6..1 822/14 no FP Fonn 8' SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address: 857 Southcenter Mall, Space 1440 Suite Number: Floor: Tenant Name: Hollister New Tenant? ❑ - Yes El - No Property Owner's Name: Westfield Shopping Center Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City E-mail Address: lig `y Fax Number: 206.628.4990 State Zip Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 1200 Scope of Work (please provide detailed information): Add 1 device to existing FRCP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER OR AUTHOR' ED AGENT: Signature: . Date: - 2—q 1 15 Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 4ist SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** c 7 /E� �p ,� King Co. Assessor's Tax No.: Site Address: 57 560- ( Ina 1/ Suite Number: /17/9n Floor: Tenant Name: it // 1 S-ier New Tenant? ❑ - Yes No Property Owner's Name: w-�. c\ Yrkanacyrrvik,-k-- Co rLJ ft Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: C VASS X 0.)0) nl 1 Day Telephone: Li 2c5 ��17( Company Name: Mailing Address: E-mail Address: 3eskcae,crou3ri��n Total number of new/relocated devices or sprinkler heads: Fax Number: r2 L/7S 4 l - gtovg- Valuation of Project (contractor's bid price): $ 2, Scope of Work (please provide detailed information): C /) Re/OC�t/i'(I4 ''Y‘ PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O OR AUT RIZ + . NT: a Signature: Print Name: je Plan Permit App.doc 1/2/13 Day Telephone: Date: i'2e•IS- L422-41* 7fo(9 TFD FP Form 8 40'44 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.:q,2O2 1 CO I (� Site Addressf3l 61TI OnCp tAst-2x �Y . Suite Number: Floor: Tenant Name:A13 Property Owner's Name: V V 12 d V''l O�,i 4L\ T ( k P pk �A C17-01 State Zip New Tenant? [ Yes ❑ - No Mailing AddressTD '.)Vq-k-kU ['n 1 City CONTACT PERSON -if t ere are questions about the submittal. Name: (ek OV pl i Day Tele hone: --v, l o Company Name: el\ kCili l CUA W(1 u �c f, rn� Mailing Address:,1 J I'* -AV e , 3 A L 12 PJ City State Zip Fax Number: Con tor's City of Tukwi a NICET III number: Business License number: &J' .CSU' Total number of new/relocated devices or sprinkler heads: 31 Valuation of Project (contractor's bid price): $ t(.Q I `-t) c Scope of Work (please provide detailed information):P (1 . (' \firi-)k-e/ Y ` i Odd �vS E-mail Address. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER OR AUTHORIZED AGENT: /� Signature. ` lam '���� 272019 Date:(} ICI Print Name c _ '!>\ .lei C);(eV &u -ilk ` Ui `N ILAL hone(X 17) o 1 '� Plan Permit App.doc 8/22/14 TFD FP Form 8 PAID SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** ^ , King Co. Assessor's Tax No..Na141 \0 "/ Site Address: %5l 6D�\4 ��/\l Suite Number: Floor: Tenant Name: \« New Tenant? ❑ - Yes (, No Property Owner's Name O(l1 W()c)PiY-ki. ', Mailing Address:A A City State Zip CONTACT PERSON -if there are questions about the submittal. Namelte-i•`(k dZ,Th( V'1�'� cIDay Telephone b(Dl `P.—,�'�-nl% Company Name: hL xc c0 Ail '�Q £1k9.-. 6 i Yl 3 Mailing Address: \1U \ Ave • 6 i Q i A $ City State Zip Fax Number: Con . I /y�y i NICET III number: Business License number: ctor's City of Tukwillr .Jl Y— ( 0t (2 s 5? Total number of new/relocated devices or sprinkler heads: (.._EJ) E-mail Address Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): VttY9_ C'_\C'(V\ P -AM 066,LAA,CA c7U Nck2,NAcsi.), PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID BUILDING OWNER OR AUTHORIZED AGENT: JUL u 1 2019 TUKWILA FIRE Date:7\I I, 11 GUI tllDV/L Day Telephone(201) (M":2 -Al -VP Signature: Print Name: Plan Permit App.doc 8/22/14 TFD FP Form 8 CITY OF TUKW I.A FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION King Co. Assessor's Tax No.: 61-Z o 2- LA 7'6010 Site Address: 2S 7 S 6 3 AAA C e (\4'r mak I Suite Number. P:111 0 Floor: Tenant Name: o \\ c- L c n o Li or k New Tenant? ❑ - Yes j - No Property Owner's Name: v '(\ . b Q1 1 - r< o� (AC o Mailing Address: 2 la) Sc)J� vt C.e (l `'C ` mat City CONTACT PERSON -if there are questions about the submittal. Name: C r\ 5 V(e- OV u r\ A Company Name: Crown C .-k(---c., ? (D C Lo n Mailing Address: i o 80X lZ c t 3 ft 1)1 state zlp E-mail Address: C N sic; C? ( c r o w A ir,Q . C o City Fax Number. Li L 5 4 8( —9( q s �i (J Contrator's City of Tukwila I , ,r� NICET III mmmber: ct 7 4i1/O/ (Ii Business License number: 8 V S- V 41 I S 81 z TOL gEt State Zip Day Telephone: ti 2 S H 81— 7 % Cr (,z G-41- q.80 2Z Total number of new/relocated devices or sprinkler heads: 12 Valuation of Project (contractor's bid price): $ I] Scope of Work (please provide detailed information): O [(� Z v7 l- k r- ►ldelrfs cpc jr-e_uJ (ore -1n d I PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR`! IJA(OTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. (,� BUILDING OWNER OR AUTHORIZED AGENT: Signature: ✓ /l/ti 4 Print Name: C r) S) p ` (,b) /aril Plan Permit Appdoc 8/22/14 TFD FP Form 8 .. _a 2019 TUKWV.A /FIRE ly Telephone: Date: 7 I Z i t 1 ft FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Hollister 857 Southcenter Mall Permit No.: 19-S-143 Date: July 22, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • Weld stamps shall be inspected on the ground, before the pipe is hung. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2019 Edition. 4. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Hollister 857 Southcenter Mall Permit No.: 15-S-072 Date: May 7, 2015 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM G 635 and ASTM C 636 per section 9.2.1.3.3.2. . • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Hollister 857 Southcenter Mall Permit No.: 19-S-178 Date: September 18, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' off the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 21/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Weld stamps shall be inspected on the ground, before pipe is hung. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2019 Edition. Apr 2715 03:OOp Crown Fire Protection FAX TRANSMITTAL 4254818695 p.1 Fax No. CROWN FIRE PROTECTION, INC. Imo: 4.27.15 Fire Prevention Bureau SEM Tukwila Fire Department ! AI MIEED Demo Permit \ umhcr ut Pa2,cs including Co%er) 1 206.575.4439 4d117 W11KWILA FIRE DEPARTMENT 'h9sse call 206-575-44137 and ;v! this Fire Permit No. /nd exact a cfor shut- ..Own hut.:own or re. mo:-2Lioi) approval. 0 Urgent 0 For Review 0 Please Comment 0 Please Reply Froin Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comments Please issue a demo permit to remove (2) sprinkler heads in the store front for the tenant improvement work at the Hollister space - 857 Southcenter Mall. The building permit # D14-0223. Thanks - FIRE POOTUCTION PPw1NNL.ER SY5TEMe John J. Abed 9790-0591-03 1es13 Glow Pre . Inc. • P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425. 481.8695 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Hollister 857 Southcenter Mall Permit No.: 08-S-076 Date: March 18, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. All references are NFPA 13, 2007 Edition. THE FIRE PROTECTION INTERNATIONAL CONSORTIUM, INC. FIRE PROTECTION - LIFE SAFETY - CODE CONSULTING SECURITY - PERFORMANCE BASED DESIGN http://www.the-fpi.com September 13, 2019 Jessica Robinson President Crown Fire Protection, Inc PO BOX 12113 Mill Creek, WA 98093 RE: Fire Protection Consulting Services Fire Sprinkler Plan Review Hollister Tl 857 Southcenter Space 1440 Tukwila, WA STATUS: Approved w/ Comments Ms. Robinson: FPI has reviewed the Fire Sprinkler Submittal Package, provided by Crown Fire Protection, for the above referenced facility. The submittal package consisted of the following: 1. Fire Protection Sprinkler Plans (Sheet 1 through 4 of 4) dated 8/15/19 and associated hydraulic calculations. Flow test data for the plans and calculations was provide by Crown. The review resulted in the following comments: 1. Prior to submittal for permitting, add Crown's state Level Ill fire sprinkler contractor stamp. 2. No Seismic bracing or calculations were provided or reviewed. No new pipe of 2 'N or larger diameter was added for this TI. Please feel free to contact me with any questions. Sincerely, Digitally signed by Carl Cart Anderson, PE Anderson, PE Date: 2°19.09.13 13:45:49 -07'00' Carl P. Anderson, PE The Fire Protection International Consortium, Inc. PmlKtion / Cons;ain ;g 11 March 2008 John Abel Crown Fire Protection PO Box 12113 Mill Creek, WA 98012 RE: Westfield Mall — Hollister Co. (Suite #1440) Independent Third Party Review — Fire Sprinkler System Dear John: Tuazon Engineering, PLLC 4322 NE 7" Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. It is noted that the sprinkler system modifications shown are to Zone T4 fed from the East Riser Room. The following was reviewed: • Fire Sprinkler Drawings — Sheet 1 dated 3/08 • Hydraulic Calculations dated 3/10/08 The documents were reviewed for compliance with the 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. The "general notes" and "design criteria" on the drawing reference 2002 and 1999 editions of NFPA 13. The correct edition is the 2007 edition per City of Tukwila Ordinance 2050, Section 16.42.020. 2. Provide restraint of all branchline piping per 2007 NFPA 13 Para 9.3.6, as enforced by the City of Tukwila. 3. Provide oversized escutcheons at sprinkler ceiling penetrations per IBC/ASCE 7 if/as required by the City of Tukwila. It is noted that flexible sprinkler connections have been used in other tenant improvement projects to satisfy this requirement. 4. Include applicable product data with the permit submittal to the City of Tukwila. 5. The hydraulic calculations conflict with the shell and core calculations by Western States Fire Protection, and don't accurately reflect the riser and underground piping. The shell and core calculations are available through the Westfield tenant coordinator (Marcia Peddicord, 206-802-6071) and should be used in future tenant improvement designs. Although there is sufficient safety margin that this will not affect final pipe sizing, the following changes are to the calculations are recommended: a. Water supply should be 140 psi static, with 10,900 gpm flowing at 20 psi residual. b. Existing 4" diameter aboveground piping is schedule 40 steel. Revise inside diameter to 4.26" in lieu of 4.310" used. c. Add 8" diameter (8.329" ID) at 27'-9" for riser room piping (includes equivalent lengths for fittings). d. Add 10" diameter (10.020" ID) at 124'-1" for riser room piping (includes equivalent lengths for fittings). e. Add 10" Wilkins 350 BFP losses (see attached data sheet). f. Add 10" diameter (10.400" ID) at 246'-6" for underground piping to water source. Westfield Mall — Hollister Co. Third Party Review — Fire Sprinkler Systems 11 March 2008 Page 2 A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or ericCa).tuazon.com with any questions regarding this review. Respectfully, TUAZON ENGINEERING, PLLC Eric P. Tuazon, PE Fire Protection Engineer Hydraulic Calculations for Project Name: HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL Location: Drawing No: C Sheet 1 REV2 1 OF 1 Date 03/14/08 Job: HOLLISTE Design: Occupancy classification: Density: Area of application: Coverage per sprinkler: ORDINARY HAZARD GP 2 0.20 gpm/sq.ft. 1500 square feet 130 S.F. MAX Type of sprinklers calculated: K=5.6 No. of sprinklers calculated: 19 heads Hose streams: 250.0 gpm Outside Hose Total water required: Including hose streams 93.20 psi @ 754.2 gpm @ Supply 139.14 psi available @ 754.2 gpm Below curve by 45.94 psi Type of System: Wet Water Supply Information: 140.00 psi Static, 20.00 psi Residual @ 10900.0 gpm Name of Contractor: CROWN FIRE PROTECTION Phone Number: 425-481-7669 Authority Having Jurisdiction: NFPA Notes: Program: 'HydroCalc' by Micro Space Systems www.MicroSpaceSystems.com ■System demand = 93.20 psi with 754.2 gpm flowing. 01 0 - 1 CD CD O O U1 O CD O O O CO a CO 0 -n O -13G) 01 O Q N CD CD CD Pressure (PSI) a CD o CD 0 0 0 CO J r -t -I. H L CO a1 -1 + a r J t L L r r f_ _ - _ y + - L J r - r J 1 L J f. O ✓ r m m L -♦ 0 n m m ii m U7 11 m r r m C fv 58-I.N aaayS 6Iewwn5 1sa j "IA HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 Sheet 3. CROWN FIRE PROTECTION Description of Fitting abbreviations Code Description T Tee E Ninety degree elbow VE Victaulic ninety degree elbow B26 Wilkens Model 350A Double Check Valve Assy. GV Gate valve UE Underground ASCA ninety degree elbow UT1 Underground ASCA tee: flow in run, flow out bullhead only Description of Other abbreviations Code Description AO Arm -over BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction A.5 Raised to the power of .5 (Square Root) L Actual pipe length F Fitting equivalent pipe length T Total pipe length Sheet 4 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Raw data previous to any calculations No. Code Diam Length Kfacl Kfac2 Press Elev Hose HW Vel Fittings 1 AO1 1.080 4.5 5.6 12.75 0.00 0.0 120 32 2E,1T 2 AO2 1.080 5.5 5.6 21.56 0.00 0.0 120 32 2E,1T 3 AO3 1.080 6.5 5.6 21.56 0.00 0.0 120 32 2E,1T 4 AO4 1.080 4.0 5.6 12.75 0.00 0.0 120 32 2E,1T 5 AO5 1.080 6.0 5.6 12.75 0.00 0.0 120 32 2E,1T 6 BL1 1.639 0.5 A01 0.00 0.00 0.0 120 32 7 BL1 1.639 9.5 AOl 0.00 0.00 0.0 120 32 8 BL1 1.639 15.0 A01 0.00 0.00 0.0 120 32 2E 9 BL1 1.639 10.0 AO2 0.00 0.00 0.0 120 32 10 BL1 1.639 10.0 AO2 0.00 0.00 0.0 120 32 11 BL1 1.639 39.0 AO3 0.00 0.00 0.0 120 32 1T 12 BL2 1.639 10.0 A01 0.00 0.00 0.0 120 32 13 BL2 1.639 12.0 A01 0.00 0.00 0.0 120 32 14 BL2 1.639 10.0 AO4 0.00 0.00 0.0 120 32 15 BL2 1.639 10.0 A04 0.00 0.00 0.0 120 32 16 BL2 1.639 39.0 AO3 0.00 0.00 0.0 120 32 1T 17 BL3 1.639 10.0 A01 0.00 0.00 0.0 120 32 18 BL3 1.639 9.0 AO1 0.00 0.00 0.0 120 32 2E 19 BL3 1.639 0.5 AO5 0.00 0.00 0.0 120 32 2E 20 BL3 1.639 9.5 AO5 0.00 0.00 0.0 120 32 21 BL3 1.639 0.5 AO5 0.00 0.00 0.0 120 32 22 BL3 1.639 9.5 AO5 0.00 0.00 0.0 120 32 23 BL3 1.639 39.0 AO3 0.00 0.00 0.0 120 32 iT 24 BL4 1.639 58.0 AO4 0.00 0.00 0.0 120 32 1T 25 CM1 4.026 11.0 BL1 0.00 0.00 0.0 120 32 26 CM1 4.026 4.0 BL2 0.00 0.00 0.0 120 32 1T 27 CM2 4.026 9.0 BL4 0.00 0.00 0.0 120 32 28 CM2 4.026 8.0 BL3 0.00 0.00 0.0 120 32 1T 29 BU 4.026 170.0 CM1 CM2 0.00 0.00 0.0 120 32 4VE 30 RI 4.026 18.0 BU 0.00 14.50 0.0 120 32 2VE,1T 31 RI 8.249 28.0 0.00 0.00 0.0 120 32 32 RI 10.370 125.0 0.00 0.00 0.0 120 32 1B26 33 UG 10.280 247.0 RI 0.00 0.00 0.0 140 32 3UE,1UT1,1GV 34 UG 10.280 0.0 0.00 0.00 250.0 140 32 CROWN FIRE PROTECTION. Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Sheet 5 Notes Arm -over 1 C = 120 L 4.5 PT 12.75 1 20.0=5.60(12.75)'.5 F 10.4 PE 0.00 1 20.0 1.08 2E 1T T 14.9 0.11288 PF 1.68 7.00 PT 14.43 6 B1 Jct K -factor for arm -over 1 = 20.0/(14.43)'.5 = 5.27 at Hyd Ref Pts 6 7 8 12 13 17 18 Arm -over 2 L 5.5 PT 21.56 2 26.0=5.60(21.56)'.5 F 10.4 PE 0.00 2 26.0 1.08 2E 1T T 15.9 0.18351 PF 2.91 9.11 PT 24.47 9 K -factor for arm -over 2 = 26.0/(24.47)'.5 = 5.26 at Hyd Ref Pts 9 10 Arm -over 3 L 6.5 PT 21.56 3 26.0=5.60(21.56)".5 F 10.4 PE 0.00 3 26.0 1.08 2E 1T T 16.9 0.18351 PF 3.10 9.11 PT 24.66 11 K -factor for arm -over 3 = 26.0/(24.66)'.5 = 5.24 at Hyd Ref Pts 11 16 23 Arm -over 4 L 4.0 PT 12.75 4 20.0=5.60(12.75)A.5 F 10.4 PE 0.00 4 20.0 1.08 2E 1T T 14.4 0.11288 PF 1.62 7.00 PT 14.37 14 K -factor for arm -over 4 = 20.0/(14.37)'.5 = 5.28 at Hyd Ref Pts 14 15 24 C = 120 B1 Jct C = 120 B1 Jct C = 120 B1 Jct CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Sheet 6 Notes Arm -over 5 C = 120 L 6.0 PT 12.75 5 20.0=5.60(12.75)'.5 F 10.4 PE 0.00 5 20.0 1.08 2E 1T T 16.4 0.11288 PF 1.85 7.00 PT 14.60 19 Bl Jct K -factor for arm -over 5 = 20.0/(14.60)'.5 = 5.23 at Hyd Ref Pts 19 20 21 22 Branchline No. 1 (Beginning pressure increased due to Hyd Ref Pt 9) C = 120 L 0.5 PT 20.09 6 AO1 23.6=5.27(20.09)A.5 F 0.0 PE 0.00 6 23.6 1.64 T 0.5 0.02012 PF 0.01 3.59 L 9.5 PT 20.10 7 AO1 23.6=5.27(20.10)'.5 F 0.0 PE 0.00 7 47.2 1.64 T 9.5 0.07254 PF 0.69 7.18 L 15.0 PT 20.79 8 AO1 24.0=5.27(20.79)A.5 F 8.7 PE 0.00 8 71.2 1.64 2E T 23.7 0.15522 PF 3.68 10.83 L 10.0 PT 24.48 9 AO2 26.0=5.26(24.48)A.5 F 0.0 PE 0.00 9 97.2 1.64 T 10.0 0.27606 PF 2.76 14.78 L 10.0 PT 27.24 10 AO2 27.4=5.26(27.24)A.5 F 0.0 PE 0.00 10 124.7 1.64 T 10.0 0.43721 PF 4.37 18.96 L 39.0 PT 31.61 11 AO3 29.4=5.24(31.61)'.5 F 8.7 PE 0.00 11 154.1 1.64 1T T 47.7 0.64719 PF 30.89 23.43 PT 62.50 25 Cross main Jct K -factor for branchline no. 1 = 154.1/(62.50)A.5 = 19.49 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Sheet 7 Notes Branchline No. 2 (Beginning pressure increased due to Hyd Ref Pt 16) C = 120 L 10.0 PT 19.44 12 AO1 23.2=5.27(19.44)A.5 F 0.0 PE 0.00 12 23.2 1.64 T 10.0 0.01951 PF 0.20 3.53 L 12.0 PT 19.64 13 AO1 23.3=5.27(19.64)A.5 F 0.0 PE 0.00 13 46.6 1.64 T 12.0 0.07067 PF 0.85 7.08 L 10.0 PT 20.48 14 AO4 23.9=5.28(20.48)A.5 F 0.0 PE 0.00 14 70.4 1.64 T 10.0 0.15203 PF 1.52 10.71 L 10.0 PT 22.00 15 AO4 24.8=5.28(22.00)A.5 F 0.0 PE 0.00 15 95.2 1.64 T 10.0 0.26539 PF 2.65 14.47 L 39.0 PT 24.66 16 AO3 26.0=5.24(24.66)A.5 F 8.7 PE 0.00 16 121.2 1.64 1T T 47.7 0.41491 PF 19.80 18.43 PT 44.46 26 Cross main Jct K -factor for branchline no. 2 = l21.2/(44.46)A.5 = 18.18 Sheet 8 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 3 (Beginning pressure increased due to Hyd Ref Pt 23) C = 120 L 10.0 PT 15.52 17 AO1 20.8=5.27(15.52)'.5 F 0.0 PE 0.00 17 20.8 1.64 T 10.0 0.01584 PF 0.16 3.15 L 9.0 PT 15.68 18 AO1 20.9=5.27(15.68)A.5 F 8.7 PE 0.00 18 41.6 1.64 2E T 17.7 0.05738 PF 1.02 6.32 L 0.5 PT 16.70 19 AO5 21.4=5.23(16.70)'.5 F 8.7 PE 0.00 19 63.0 1.64 2E T 9.2 0.12364 PF 1.14 9.58 L 9.5 PT 17.84 20 AO5 22.1=5.23(17.84)'.5 F 0.0 PE 0.00 20 85.1 1.64 T 9.5 0.21573 PF 2.05 12.94 L 0.5 PT 19.89 21 AO5 23.4=5.23(19.89)'.5 F 0.0 PE 0.00 21 108.4 1.64 T 0.5 0.33782 PF 0.17 16.49 L 9.5 PT 20.06 22 AO5 23.5=5.23(20.06)A.5 F 0.0 PE 0.00 22 131.9 1.64 T 9.5 0.48523 PF 4.61 20.05 L 39.0 PT 24.67 23 AO3 26.0=5.24(24.67)A.5 F 8.7 PE 0.00 23 157.9 1.64 1T T 47.7 0.67694 PF 32.31 24.01 PT 56.98 28 Cross main Jct K -factor for branchline no. 3 = 157.9/(56.98)'.5 = 20.92 Branchline No. 4 C = 120 L 58.0 PT 14.37 24 AO4 20.0=5.28(14.37)^.5 F 8.7 PE 0.00 24 20.0 1.64 1T T 66.7 0.01481 PF 0.99 3.04 PT 15.36 27 Cross main Jct K -factor for branchline no. 4 = 20.0/(15.36)'.5 = 5.10 Sheet 9 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 1 C = 120 L 11.0 PT 62.50 25 BL1 154.1=19.49(62.50)".5 F 0.0 PE 0.00 25 154.1 4.03 T 11.0 0.00813 PF 0.09 3.88 L 4.0 PT 62.59 26 BL2 143.8=18.18(62.59)".5 F 20.0 PE 0.00 26 297.9 4.03 1T T 24.0 0.02754 PF 0.66 7.51 PT 63.25 29 Bulk Jct K -factor for Cross main 1 = 297.9/(63.25)".5 = 37.46 Cross main 2 (Beginning pressure increased due to Hyd Ref Pt 28) C = 120 L 9.0 PT 56.98 27 BL4 38.5=5.10(56.98)".5 F 0.0 PE 0.00 27 38.5 4.03 T 9.0 0.00063 PF 0.01 0.97 L 8.0 PT 56.98 28 BL3 157.9=20.92(56.98)".5 F 20.0 PE 0.00 28 196.4 4.03 1T T 28.0 0.01275 PF 0.36 4.95 PT 57.34 29 Bulk Jct K -factor for Cross main 2 = 196.4/(57.34)".5 = 25.94 CROWN FIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 C Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Bulk K=63.39=37.45+25.94 L 170.0 PT 63.25 29 504.2=63.39(63.25)A.5 F 27.2 PE 0.00 29 504.2 4.03 4VE T 197.2 0.07289 PF 14.37 12.71 PT 77.62 30 Sheet 10 Notes C = 120 CM 1 + CM 2 Top of Riser Riser C = 120 L 18.0 PT 77.62 30 Top of Riser F 33.6 PE 6.28 (EL= 14.50 ft) 30 504.2 4.03 2VE 1T T 51.6 0.07290 PF 3.76 12 71 L 28.0 PT 87.66 31 F 0.0 PE 0.00 31 504.2 8.25 T 28.0 0.00222 PF 0.06 3.03 L 125.0 PT 87.73 32 F 0.0 PE 0.00 32 504.2 10.37 1B26 T 125.0 0.00073 PF 5.28 1.92 1B26 = 5.19* PT 93.01 33 B.O.R. Under ground C = 140 L 247.0 PT 93.01 33 B.O.R. F 88.1 PE 0.00 33 504.2 10.28 3UE lUT1 T 335.1 0.00057 PF 0.19 1.95 1GV L 0.0 PT 93.20 34 250.0 gpm = Hose F 0.0 PE 0.00 34 754.2 10.28 T 0.0 0.00000 PF 0.00 2.92 PT 93.20 35 Supply Jct Available flow at 93.20 psi is 6552.1 gpm which is 5797.9 gpm from curve. Supply pressure available with 754.2 gpm flowing is 139.14 psi, thus system requirement is 45.94 psi below supply curve. (33.0%) HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 Sheet 11 Supply Analysis Node at Static Residual Available Total Required Source Pressure Pressure Flow Pressure Demand Pressure 35 140.00 20.00 10900.0 139.14 754.2 93.20 Node Analysis Elevation Node Type Pressure Discharge Node (ft) K -Value Source (psi) (gpm) Notes 1 14.50 Orif= 5.60 12.75 20.0 2 14.50 Orif= 5.60 21.56 26.0 3 14.50 Orif= 5.60 21.56 26.0 4 14.50 Orif= 5.60 12.75 20.0 5 14.50 Orif= 5.60 12.75 20.0 6 14.50 20.09 - 7 14.50 20.10 8 14.50 20.79 9 14.50 24.48 10 14.50 27.24 11 14.50 31.61 12 14.50 19.44 - 13 14.50 19.64 14 14.50 20.48 15 14.50 22.00 16 14.50 24.66 17 14.50 15.52 18 14.50 15.68 19 14.50 16.70 20 14.50 17.84 21 14.50 19.89 22 14.50 20.06 23 14.50 24.67 24 14.50 14.37 25 14.50 62.50 26 14.50 62.59 27 14.50 56.98 28 14.50 56.98 29 14.50 63.25 30 14.50 77.62 31 0.00 87.66 - 32 0.00 87.73 - 33 0.00 93.01 - 34 0.00 Hose 93.20 250.0 35 0.00 93.20 - HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 Sheet 12 Pipe Information Nodel Elevl Kfactor Qadd Nominal Fittings L (ft) Cfac Total Pt Pipe (ft) Hose ID F (ft) Vel Elev Pe Node2 Elev2 Qtot Actual Length T (ft) Psi/Ft Fric Pf Notes 1 1 14.50 5.60 6 14.50 20.0 1" 2E 1T L 4.5 120 Pt 12.75 F 10.4 7.0 Pe 0.00 20.0 1.08 10.4 T 14.9 0.1129 Pf 1.68 AO1:K=5.27 2 2 14.50 5.60 9 14.50 26.0 1" 2E 1T L 5.5 120 Pt 21.56 F 10.4 9.1 Pe 0.00 26.0 1.08 10.4 T 15.9 0.1835 Pf 2.91 A02:K=5.26 3 3 14.50 5.60 11 14.50 26.0 1" 2E iT L 6.5 120 Pt 21.56 F 10.4 9.1 Pe 0.00 26.0 1.08 10.4 T 16.9 0.1835 Pf 3.10 A03:K=5.24 4 4 14.50 5.60 14 14.50 20.0 1" 2E iT L 4.0 120 Pt 12.75 F 10.4 7.0 Pe 0.00 20.0 1.08 10.4 T 14.4 0.1129 Pf 1.62 A04:K=5.28 5 5 14.50 5.60 19 14.50 20.0 1" 2E 1T L 6.0 120 Pt 12.75 F 10.4 7.0 Pe 0.00 20.0 1.08 10.4 T 16.4 0.1129 Pf 1.85 A05:K=5.23 6 14.50 5.27 [23.6] 1 1/2" L 0.5 120 Pt 20.09 A01 6 F 0.0 3.6 Pe 0.00 7 14.50 23.6 1.64 T 0.5 0.0201 Pf 0.01 7 14.50 5.27 [23.6] 1 1/2" L 9.5 120 Pt 20.10 AO1 7 F 0.0 7.2 Pe 0.00 8 14.50 47.2 1.64 T 9.5 0.0725 Pf 0.69 8 8 14.50 5.27 [24.0] 1 1/2" 2E 9 14.50 71.2 1.64 L 15.0 120 Pt 20.79 A01 F 8.7 10.8 Pe 0.00 8.7 T 23.7 0.1552 Pf 3.68 9 9 14.50 5.26 [26.0] 1 1/2" 10 14.50 97.2 1.64 L 10.0 120 Pt 24.48 A02 F 0.0 14.8 Pe 0.00 T 10.0 0.2761 Pf 2.76 10 10 14.50 5.26 [27.4] 1 1/2" 11 14.50 124.7 1.64 L 10.0 120 Pt 27.24 A02 F 0.0 19.0 Pe 0.00 T 10.0 0.4372 Pf 4.37 11 11 14.50 5.24 [29.4] 1 1/2" iT 25 14.50 154.1 1.64 L 39.0 120 Pt 31.61 A03 F 8.7 23.4 Pe 0.00 8.7 T 47.7 0.6472 Pf 30.89 BL1:K=19.49 12 12 14.50 5.27 [23.2] 1 1/2" 13 14.50 23.2 1.64 L 10.0 120 Pt 19.44 AO1 F 0.0 3.5 Pe 0.00 T 10.0 0.0195 Pf 0.20 HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL REV2 Sheet 13 Pipe Information Nodel Elevl Kfactor Qadd Nominal Fittings L (ft) Cfac Total Pt Pipe (ft) Hose ID F (ft) Vel Elev Pe Node2 Elev2 Qtot Actual Length T (ft) Psi/Ft Fric Pf Notes 13 13 14.50 5.27 [23.3] 1 1/2" 14 14.50 46.6 1.64 L 12.0 120 Pt 19.64 AO1 F 0.0 7.1 Pe 0.00 T 12.0 0.0707 Pf 0.85 14 14 14.50 5.28 [23.9] 1 1/2" 15 14.50 70.4 1.64 L 10.0 120 Pt 20.48 A04 F 0.0 10.7 Pe 0.00 T 10.0 0.1520 Pf 1.52 15 15 14.50 5.28 [24.7] 1 1/2" 16 14.50 95.2 1.64 L 10.0 120 Pt 22.00 A04 F 0.0 14.5 Pe 0.00 T 10.0 0.2654 Pf 2.65 16 16 14.50 5.24 [26.0] 1 1/2" 1T 26 14.50 121.2 1.64 L 39.0 120 Pt 24.66 A03 F 8.7 18.4 Pe 0.00 8.7 T 47.7 0.4149 Pf 19.80 5L2:K=18.18 17 17 14.50 5.27 [20.7] 1 1/2" 18 14.50 20.8 1.64 L 10.0 120 Pt 15.52 AO1 F 0.0 3.2 Pe 0.00 T 10.0 0.0158 Pf 0.16 18 14.50 5.27 [20.8] 1 1/2" 2E L 9.0 120 Pt 15.68 A01 18 F 8.7 6.3 Pe 0.00 19 14.50 41.6 1.64 8.7 T 17.7 0.0574 Pf 1.02 19 14.50 5.23 [21.4] 1 1/2" 2E L 0.5 120 Pt 16.70 A05 19 F 8.7 9.6 Pe 0.00 20 14.50 63.0 1.64 8.7 T 9.2 0.1236 Pf 1.14 20 14.50 5.23 [22.1] 1 1/2" L 9.5 120 Pt 17.84 A05 20 F 0.0 12.9 Pe 0.00 21 14.50 85.1 1.64 T 9.5 0.2157 Pf 2.05 21 14.50 5.23 [23.3] 1 1/2" L 0.5 120 Pt 19.89 A05 21 F 0.0 16.5 Pe 0.00 22 14.50 108.4 1.64 T 0.5 0.3378 Pf 0.17 22 14.50 5.23 [23.4] 1 1/2" L 9.5 120 Pt 20.06 A05 22 F 0.0 20.1 Pe 0.00 23 14.50 131.9 1.64 T 9.5 0.4852 Pf 4.61 23 14.50 5.24 [26.0] 1 1/2" 1T L 39.0 120 Pt 24.67 A03 23 F 8.7 24.0 Pe 0.00 28 14.50 157.9 1.64 8.7 T 47.7 0.6769 Pf 32.31 BL3:K=20.92 24 24 14.50 5.28 [20.0] 1 1/2" 1T 27 14.50 20.0 1.64 L 58.0 120 Pt 14.37 A04 F 8.7 3.0 Pe 0.00 8.7 T 66.7 0.0148 Pf 0.99 BL4:K=5.10 HOLLISTER TENANT - SOUTHCENTER WESTFIELD MALL Pipe Information REV2 Sheet 14 Nodel Elevl Kfactor Qadd Nominal Fittings L (ft) Cfac Total Pt Pipe (ft) Hose ID F (ft) Vel Elev Pe Node2 Elev2 Qtot Actual Length T (ft) Psi/Ft Fric Pf Notes 25 14.50 19.49 [154.1] 4" L 11.0 120 Pt 62.50 BL1 25 F 0.0 3.9 Pe 0.00 26 14.50 154.1 4.03 T 11.0 0.0081 Pf 0.09 26 14.50 18.18 [143.8] 4" 1T L 4.0 120 Pt 62.59 BL2 26 F 20.0 7.5 Pe 0.00 29 14.50 297.9 4.03 20.0 T 24.0 0.0275 Pf 0.66 27 14.50 5.10 [38.5] 4" L 9.0 120 Pt 56.98 BL4 27 F 0.0 1.0 Pe 0.00 28 14.50 38.5 4.03 T 9.0 0.0006 Pf 0.01 28 14.50 20.92 [157.9] 4" 1T L 8.0 120 Pt 56.98 BL3 28 F 20.0 5.0 Pe 0.00 29 14.50 196.4 4.03 20.0 T 28.0 0.0127 Pf 0.36 29 29 14.50 30 14.50 4" 4VE L 170.0 120 Pt 63.25 CM 1 + CM 2 F 27.2 12.7 Pe 0.00 504.2 4.03 27.2 T 197.2 0.0729 Pf 14.37 30 14.50 4" 2VE iT L 18.0 120 Pt 77.62 Top of Riser 30 F 33.6 12.7 Pe 6.28 31 0.00 504.2 4.03 33.6 T 51.6 0.0729 Pf 3.76 31 0.00 8" L 28.0 120 Pt 87.66 31 F 0.0 3.0 Pe 0.00 32 0.00 504.2 8.25 T 28.0 0.0022 Pf 0.06 32 32 0.00 33 0.00 12" 504.2 10.37 L 125.0 120 Pt 87.73 F 0.0 1.9 Pe 0.00 1B26 = 5.19# T 125.0 0.0007 Pf 5.28 33 0.00 10" 3UE lUT1 L 247.0 140 Pt 93.01 33 1GV F 88.1 1.9 Pe 0.00 34 0.00 504.2 10.28 88.1 T 335.1 0.0006 Pf 0.19 34 0.00 10" L 0.0 140 Pt 93.20 34 250.0 F 0.0 2.9 Pe 0.00 35 0.00 754.2 10.28 T 0.0 0.0012 Pf 0.00 Supply J.8 — BUND SPACE METAL AND CONCRETE ALL FIRE—PROOFED STEEL NO SPRINKLERS 1" RETURN—BEND TYPICAL STEEL I—BEAM 1 1/2' BRANCH UNE PIPE METAL PAN DECK CONCRETE CEILING 3/8' EXPANSION INSERT TO EXIST FLOOR DECK 1' RING HANGAR AT EVERY ARM OVER RUN ROD TIGHT TO PIPE EG r 1 4' CROSS MAIN i SUSPENDED T—BAR CEILING TYPICAL CONCRETE FLOOR I t BLACK CONCEALED SPRINKLER HEAD FIRE PROTECTION NOTES ARE SPRINKLER SYSTEM TO PROVIDE 100% SPRINKLER COVERAGE IN ALL AREAS PER THE STATE AND LOCAL FIRE MARSHALL. WHENEVER POSSIBLE ALIGN SPRINKLER HEADS WITH LIGHT FIXTURES, AIR DEVICES AND TO CENTER OF TILE. THE PATTERN IN EACH ROOM SHALL BE CONSIDERED INDEPENDENT OF OTHER ROOMS, ROUTE ALL PIPING AROUND ELECTRICAL PANELS. COORDINATE WITH ELECTRICAL CONTRACTOR. PROVIDE SPRINKLER HEADS GUARDS IN ALL LOCATIONS SUBJECT TO DAMAGE. FABRICATION, ERECTION AND TESTING OF AL PIPING SYSTEMS SHALL BE IN ACCORDANCE WITH OWNERS GENERAL REQUIREMENTS, N.F.P.A. #13, 24, 231 & 231C, AND LOCAL CODE & AUTHORITIES. SPRINKLER PIPES FEEDING COVERAGE BELOW _STORAGE DECKS ARE TO BE FED BY ROUTHING LINES DOWN FULL HEIGHT WALLS - AROUND PERIMETER OF DECK. FULL OPEN CLEARANCE OF STORAGE DECK IS TO BE MAINTAINED. FIRE SPRINKLER SPACING NOTE: SPRINKLER HEADS ARE NOT TO EXCEED 130 SQUARE FOOT. SPACING FOR ORDINARY HAZARD OCCUPANCY SECTIO\ A 1/4"=1' DESIGN CRITERIA DESIGN AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE LOCAL BUILDING CODE, N.F.P.A. 13 (1999 EDITION), AND ALL AUTHORITIES HAVING JURISDICTION. ORDINARY HAZARD (GROUP 2) AREAS: DENSITY: DESIGN AREA: MAX SPRINKLER COVERAGE: HOSE DEMAND: DURATION: 0.20 GPM/SQ.FT MOST DEMANDING 1500 SQ. FT. 130 SQ. FT./HEAD 250 GPM 60 MINUTES SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS" 1. "SALES" AREA SPRINKLER HEADS ARE TO BE FLAT OR MATTE BLACK SEMI—RECESSED HEADS WITH FLAT OR MATTE BLACK ESCUTCHEON. BASED ON RELIABLE AND ALTERNATE MAY BE VIKING OR GRINNELL AND MUST BE APPROVED BY THE HOLLISTER CONSTRUCTION MANAGER PRIOR TO ORDERING AND ANY INSTALLATIONS. ALL EXPOSED; PIPING SHALL BE PAINTED BROWN IN COLOR AND MUST BE COORDINATED WITH ALL TRADES. 2. "PORCH" AREA SPRINKLER HEADS ARE TO BE FLAT OR MATTE BLACK SEMI—RECESSED HEADS WITH FLAT OR MATTE BLACK ESCUTCHEON. BASE BID TO BE RELIABLE MODEL OR EQUAL. 3. "NON—SALES" AREA SPRINKLER HEADS ARE TO BE WHITE CONCEALED HEADS WITH WHITE ESCUTCHEON. BASED ON RELIABLE AND ALTERNATE MAY BE VIKING OR GRINNELL. 4. "NON—SALES" OFFICE AND LAVATORY AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE. 5. "MALL BULKHEAD" AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE. THE DESIGN INTENT IN THE RETAIL STORE AREAS IS TO INSTALL THE SPRINKLERS CENTERED BETWEEN THE BATTENS MOUNTED ON THE CEILING. i PROVIDE SPRINKLER HEADS (UP RIGHT) ABOVE THE CEILING IN CONCEALED SPACES HAVING EXPOSED COMBUSTIBLE CONSTRUCTION. BRANCH LINE RESTRAINT (NEW BRANCH PIPE ONLY) A. ALL SPRINKLER SYSTEM BRANCH LINES SHALL BE RESTRAINED AGAINST EXCESSIVE MOVEMENT PER THE FOLLOWING MINIMUM CRITERIA LISTED BELOW. IF THE BRANCH LINES ALLOW PENDENT SPRINKLER HEADS TO MOVE MORE THAN 3" FROM THE STAGNANT POSITION (FROM A LIGHT PUSH) AFTER INSTALLATION OF THE SYSTEM, ADDITIONAL RESTRAINT OF THE SPRINKLER DROPS SHALL BE PROVIDED. B. BRANCH LINES UP TO 20'-0" LONG SHALL REQUIRE NO ADDITIONAL MEANS OF RESTRAINTS PROVIDED THAT THE END HANGER RESTRAINS UPWARD MOVEMENT OF THE END SPRINKLER HEAD. C. BRANCH LINES FROM 20'-0" UP TO 40'-0" LONG SHALL REQUIRE ADDITIONAL MEANS OF RESTRAINT IN BOTH THE UPWARD AND LATERAL DIRECTIONS. ADDITIONAL RESTRAINT SHALL BE AT THE LAST SPRINKLER HEAD AT THE MIDPOINT OF THE BRANCH LINE. GENERAL NOTES >> ALL ABOVE GROUND FIRE PROTECTION SYSTEMS SHALL BE HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HOURS WITH NO VISIBLE LEAKAGE. ALL CONCEALED PIPING SHALL BE AIR TESTED, WITH NO LEAKAGE, PRIOR TO FILLING SYSTEM WITH WATER. THE FIRE PROTECTION CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AUTHORITIES HAVING JURISDICTION 24 HOURS PRIOR TO THE TEST. THE ENGINEER SHALL WITNESS ALL TESTS. THE FIRE SPRINKLER SYSTEM SHALL BE SUPERVISED BY AN APPROVED CENTRAL STATION, PROPRIETARY STATION, OR REMOTE STATION MONITORING SYSTEM IN ACCORDANCE WITH N.F.P.A. 72, AND LOCAL AUTHORITY HAVING JURISDICTION. by others THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE WIRING OF ALL ELECTRICAL FIRE PROTECTION DEVICES AND EQUIPMENT WITH THE ELECTRICAL AND/OR FIRE ALARM CONTRACTOR. ALL FIRE ALARM WIRING BY ELECTRICAL CONTRACTOR. ALL DEVICES SHALL BE FURNISHED AND INSTALLED BY THE FIRE PROTECTION CONTRACTOR. THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE THE LAYOUT OF THE FIRE PROTECTION SYSTEM WITH ALL TRADES AND ARCHITECTURAL REFELECTED CEILING PLAN PRIOR TO INSTALLATION. THE FIRE PROTECTION CONTRACTOR SHALL CENTER (WITHIN 1") ALL PENDENT SPRINKLER HEADS INSTALLLED IN ACOUSTICAL LAY—IN CEILING TILES. ALL PENDANT SPRINKLER HEADS IN CEILINGS SHALL BE SYMMETRICAL WITH LIGHTING AND AIR DEVICES. SPRINKLER HEADS ARE REQUIRED ABOVE THE CEIUNG IN ALL AREAS OF CONCEALED SPACES. THE LOCATION OF EXTERIOR FIRE PROTECTION EQUIPMENT SUCH AS FIRE DEPARTMENT CONNECTIONS, TEST DRAINS, ETC., SHALL BE COORDINATED WITH THE ASSOCIATE ARCHITECT AND APPROVED BY THE LOCAL FIRE DEPARTMENT. FINAL APPROVAL IS SUBJECT TO ACCEPTANCE AND TESTING BY ALL AUTHORITITIES HAVING JURISDICTION. CONTRACTOR SHALL SEAL ALL PENETRATIONS OF FIRE RATED ASSEMBLIES (WALLS, FLOORS, ETC.) AS REQUIRED TO MAINTAIN SASSEMBLY RATING. REFER TO ARCHITECTURAL PLANS FOR FIRE RATINGS. WIRE USED FOR RESTRAINT SHALL BE LOCATED WITHIN 2 FT. OF A HANGER. THE HANGER CLOSEST TO A WIRE RESTRAINT SHALL BE OF A TYPE THAT RESIST UPWARD MOVEMENT OF A BRANCH UNE. 2—#8x1 /2" CONCRETE OVER SELF TAPPING SCREWS. OR HILTI TZ ANCHORS STEEL DECK STEEL STRA 3" WIDE x 4" LONG x 12 GAL ATR SHALL BE TIGHT TO TOP OF PIPE AT END OF UNE, TO PREVENT VERTICAL MOVEMENT D. BRANCH LINES OVER 40'-0" LONG SHALL REQUIRE ADDITIONAL MEANS OF RESTRAINT IN BOTH THE UPWARDS AND LATERAL DIRECTIONS. ADDITIONAL RESTRAINT SHALL BE AT THE LAST SPRINKLER HEAD AND AT A MAXIMUM OF 30'-0" INTERVALS ALONG THE LENGTH OF THE BRANCH LINE. E. UPWARD RESTRAINT SHALL BE PERFORMED AT EACH HANGER ASSEMBLY BY BOTTOMING OUT THE HANGING ROD AGAINST THE SPRINKLER PIPING. F. LATERAL RESTRAINT SHALL BE PERFORMED IN INTERVALS NOT EXCEEDING 3O'-0" BY ADDING RESTRAINING WIRES IN BOTH LATERAL DIRECTIONS. (SEE DETAIL ABOVE) SPLAYED SEISMIC BRACING WIRE 2 TIGHT TURNS AROUND PIE END OF LINE RESTRAINT • SPKR. LINE FOUR TIGHT TURNS PER PLAN SCALE: N.T.S. I—BEAM © ROOF --_�RFTAINFR II ACC Air .F2 D O Without Comments O As Noted in Red '6r Per The Attached Letter These plans have t'e,r reviewed by The Tukwila Fire �'revention Burek.- `°-for,nance with current City andarJs. acc ubiect to errors and ..;in isslons which c:E r :-, r. ; -Qr Sze violations of adopted ? - dards and or i. o!--- -' Tine fespohsibility for the '. ;.'quaoy of oesi * ' : e''+' with the ciesigner. Additions, deiet;c.:..�: ,__ these drawings after this date viii void •,,',:1 •,z3,: E-: and will require a re:submittai cr . i ,. •};, _ .. e. cent approval, Final acceptax: ; ei:1 1rc:=3t and inspection by The Tukwila ti ¢. „ F.:130f): i :3 r: u. Date: -12 - 19 LOt7V-g/(3-90 , IPO suolpoedcul einpegos of JequanN pulled gild 3/8" BEAM CLAMP 3/8" ATR Fire Ferm t To schedule inspections colt 206-575-4407 MALL KEY PLAN HOLLISTER Co. SPACE #1440 LEVEL 1 OF 1 NORDSTROM JCF:erPeY MI NEAREST MALL PUBLIC RESTROOM NOTE: ALL QUICK BOLTS TO BE "HILTI TZ " TYPICAL MAIN HANGER © BEAMS CONCRETE ANCHOR ALL THREAD ROD DRILLED CONC. ANCHOR HANGER p WAaHW TON rra ORRTWICAT O+< C PIR* PROTECTION SPRINKLER $Y$I*MS John Thomas DeMertino 9794 -1001 -CG Level 3 Crown Fin Protection, Inc. CROWNFP044LL REVISION 1 09/05/2019 (I; aroma REVIEWED THE FPI CONSORTIUM, INC. X_ No Comments/No Exceptions Taken Make Corrections As Noted Revise and Resubmit Reviewed for general conformance with the Design Basis. This review is not intended to authorize any work not in accordance with Code. By: ---�E ----- Date:9L1.3/201..9 SEE ATTACHED REVIEW LETTER Carl Digitally signed by Carl Anderson, PE Anderson, PE Date: 2019.09.13 13:48:48 -07'00' • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILLI CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 HOLLISTER 857 SOUTHCENTER MALL SPACE #1440 SEATTLE, WASHINGTON 98188 DATE: 08/15/2019 DRAWN: NA SCALE: NOTED 1 OF 4 Design Area 3 Wet System GUY'S 109 AND SERVICE Demand Calculations using Hazen -Williams Method Occupancy Classification: OH GP 2 Design Area Density: 0.20 Additional Outside Hose: 250 Design Area Size: 980 Notes: Calculation results for Design Area 1 - GIRLS 104 AREA 980 SQ FT MATCH EXISTING HEIGHT +/-12'-0" PRE -FIN 9,-10" C-2 P -13L WOME�J'�S 112 tufEN'S 113 WD. TRIM P -12K 10'-5 1/2" NEW SCH 10 PIPE 7'-8 3/4" GUY'S 1 103 1o'-7" C-3 P -2A 10'-0" C-6 PRE -FIN OVE MALL FLOOR EXISTIN PIPE T 1 " BRANCH ICAL 112 LOUNGE 4" CROSS MAIN NEW SCH 10 PIPE 7'-8 3/4" 1 1 •�� B 3-1-- -`2,‘,4-712 r 1 NEW SCH 10 PIPE I .cr. t 112 GIRL'S 2 10'-5 1/2" 368 RESTRAINT TYPICAL 10 PIPE i 1ACOVE FLOOR UNLESS NOTED OTHERWISE CEILING ELEVATION: 17'6" MAIN PIPE ELEVATION: 15'4" BRANCH PIPE ELEVATION: 16' ELEVATION FROM JOB REF: 0' Design Area 1 Wet System GIRLS 104 AREA Demand Calculations using Hazen -Williams Method Occupancy Classification: OH GP 2 Design Area Density: 0.20 Additional Outside Hose: 250 Design Area Size: 912 Notes: AREA RED. QR HEADS CEILING HGT 1-fT-TT-TTT7-T ItififffiffiftffitittifffflittftlEnfffili Effliftliffif NI /ITCH XISTING HEIGHT f all PRE -FIN. 1 £if it 111 MUM k f #SII L IIH Effif1 I IIb 912 SQ FT, 1056 SQ FjT NI 1 TRI P -12K v 112 v 1 r C7 s This system as shown on company print no for Job Name at contract no a maximum area of 912 ft2 Hose stream allowance of dated 2 floor area over 0.2 m/ft (L/min/m2)of a e is designed ned to discharge at a rate of 9P 9 9 when supplied with water at a rate of 285 qpm at 39.2 psi at the base of the riser. is included in the above. Occupancy classification: OH GP 2 Number of heads flowing: 13 Commodity classification: System Type: Wet Maximum storage height: Maximum velocity: 12.6 ft/s Storage arrangement: Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: 0 gpm 285 gpm 0 gpm 0 gpm 0 qpm 285 gpm 250 qpm 535 gpm Pressure Required at Source: 39.2 psi Pressure Available at Source: 144.6 psi Surplus Pressure at Source: 105.4 psi Calculation results for Design Area 2 - GIRLS 108 AREA This system as shown on company print no for Job Name at dated 2 at rate of 0.2 gpm/ft2(L/min/m2) of floor area over contract no is designed to discharge a ( ) a maximum area of 1056 ft2 when supplied with water at a rate of 335.3 qpm at 41.1 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: OH GP 2 Number of heads flowing: 17 Commodity classification: System Type: Wet Maximum storage height: Maximum velocity: 13.24 ft/s Storage arrangement: Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: O gpm 335.3 gpm 0 gpm 0 gpm 0 qpm 335.3 gpm 250 qpm 585.3 gpm Pressure Required at Source: 41.1 psi Pressure Available at Source: 143.7 psi Surplus Pressure at Source: 102.6 psi P -38B 7-11" WD. TRIM SF -29 8'-0" WOOD P-3 112 1 1- Design Area 2 Wet System GIRLS 108 AREA Demand Calculations using Hazen -Williams Method Occupancy Classification: OH GP 2 Design Area Density: 0.20 Additional Outside Hose: 250 Design Area Size: 1056 Notes: AREA RED. FOR QR HEADS AND CEILING HGT. Calculation results for Design Area 3 - GUY'S 109 AND SERVICE 0 PLAN VIEW 3/16"=1'-0" This system as shown on company print no for Job Name at dated contract no is designed to discharge at a rate of 0.2 gpm/ft2 (L/min/m2) of floor area over a maximum area of 980 ft2 when supplied with water at a rate of 265.4 qpm at 49.7 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: OH GP 2 Number of heads flowing: 13 Commodity classification: System Type: Wet Maximum storage height: Maximum velocity: 15.09 ft/s Storage arrangement: Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: O gpm 265.4 gpm 0 gpm 0 gpm 0 qpm 265.4 gpm 250 qpm 515.4 gpm Pressure Required at Source: 49.7 psi Pressure Available at Source: 145 psi Surplus Pressure at Source: 95.3 psi CEIUNG TILE SPRINKLER HEAD DETAIL OF ACCEPTABLE HEAD PLACEMENT UNLESS NOTED CENTER HEADS IN TILES AS SHOWN FITTER NOTE: ALL PENDANT SPRINKLES WITHIN ROOMS AND HALL WAYS MUST LINE UP SYMMETRICAL. FIRE PROTECTION LEGEND SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# 0 97 CONCEALED PEND BLACK 155 5.60 1/2" REUABL REUABL G5-56 0 3 CONCEALED PEND WHITE 155 5.60 1/2" R3615 REL. F1 FR 0 2 UPR BRASS 155 5.60 1/2" RA1425 REUABL F1FR56 0 4 CONCEALED PEND BLACK 155 5.60 1/2" REUABL REUABL G5-56 106 SPRINKLERS TOTAL TENANT SPRI \KLER PLAN SCALE: 3/16" = 1'-0" 1 1 1 1 1 I 0 4' 8' REVISION 1 09/05/2019 I 16' 24' • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 HOLLISTER 857 SOUTHCENTER MALL SPACE #1440 SEATTLE, WASHINGTON 98188 DATE: 08/15/2019 DRAWN: NA SCALE: NOTED 2 OF 4 0 L MATCH EXISTING HEIGHT C-1 PRE -FIN. 9'-10" C-2 P -13L WOMEN'S WD. TRIM M EN'$ 13 10'-5 1/2" C-3 P -2A 7'-8 3/4" C-3 P -13A PRE -FIN ABOVE MALL FLOOR 7'-8 3/4" C-3 9'-6" C-3 N/A GIRL'S 1 104 GIRL'' 2 10'-5 1/2" C-3 P -2A 9'-3" WD. TRIM P -12K ITTIN OGR1 ALCOVE 3101 tam tlrrr� +/-12'-0" C-1 PRE -FIN. 7'-1" C-3 C-3 P -39B P -13A MATCH EXISTING HEIGHT TENANT SPRINKLER PLAN 0 SCALE: 1 /4" = 1'-O" I I I I I I 0 4' 8' 16' 24' TRIM P -12K DEFLECTED CEILING PLAN VIEW 1/4"=1'-0" FIRE PROTECTION LEGEND SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# 97 CONCEALED PEND BLACK 155 5.60 1/2" REUABL REUABL G5-56 0 3 :ONCEALED PEND WHITE 155 5.60 1/2" R3615 REL F1 FR 0 2 UPR BRASS 155 5.60 1/2" RA1425 REUABL F1FR56 O 4 CONCEALED PEND BLACK 155 5.60 1/2" RELIABL REUABL G5-56 106 SPRINKLERS TOTAL CEILING 11LE SPRINKLER HEAD 7'-11" WD. TRIM SF -29 PRE -FIN. 8'-0" PRE -FIN. CABINET VAT h J('r DETAIL OF ACCEPTABLE HEAD PLACEMENT UNLESS NOTED CENTER HEADS IN TILES AS SHOWN FITTER NOTE: ALL PENDANT SPRINKLES WITHIN ROOMS AND HALL WAYS MUST UNE UP SYMMETRICAL. 9'-6" C-2 P -35L REVISION 1 09/05/2019 • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL; CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 HOLLISTER 857 SOUTHCENTER MALL SPACE #1440 SEATTLE, WASHINGTON 98188 DATE: 08/15/2019 DRAWN: NA SCALE: NOTED 3 OF 4 980 SQ FT 1 I I I MATCH EXISTING HEIGHT DUS1110 OUT—IN 1O CITY MAN Source Information Date of Flow Test 1 Info : 03/12/2019 Location of flow test data : SITE CLOSEST HYDRANT Source of flow test data : HOLLISTER ORIGINAL DESIGN CROWN FIRE Source Data Points Pump Data Points Pressure I Flow Pressure I Flow 150.00 0.00 20.00 3000.00 10' CI SUPPLY SOUTH MALL =NOR WAIL r t• RISER FOR 1115 SPACE II VALVE ROOM DOS= SPRNIOER RISER WOMEN'S , GUY3 NEW SOH 10 PPE EASING SPRINKLER RISER M MAN 2' 21 1112 I 0 1 I 10 �93J.E3a,PL 110 1 ' ""SEC TON R2 ! 4 'TKHHa347.V PL 4 IV -1 FR C'a3i4/ 10 10 SECTION R1 LOUNGE Y 1' SNAP -MFT 11061 NG102I RESERANT WIC,/ E)OSIIIG RISERS FOR CALCIILAINNS 1 -1 -14 -14441 -M+1+1 -1- 11-M +HfH H+H}HHfU+H I+141-1+1114114H+FHH 3FHH+IF 1 j I !MU 11+U++Ek}H{ 1 Hf a 1 WATER SUPPLY & PARTIAL SITE PLAN 1/8"=1'-0" A COVE401i■■i-� illi t111 11A.ijiP 13C� MitI I+H+I+H+ urn :1-141+I+ffl 14+14LH+H+IH-IH PLAN VIEW 3/16"=1'-0" REVISION 1 09/05/2019 CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 HOLLISTER 857 SOUTHCENTER HALL SPACE #1440 SEATTLE, WASHINGTON 98188 DATE: 08/15/2019 DRAWN: NA SCALE: NOTED 4 OF 4 EFTIED ,� Without Comments 'p As Noted in Red p Per The Attached Letter These plans have been reviewed by The Tukwila Fire evention Bureau for conformance with current City andards. 5,ccePtance is subject to errors and ::nissions hlch do not authorize violations of adopted -:zandards aid ordinances. The responsibility for the adequacy o' design rests tot-a.ily with the designer. Additions, ceietiong, to these drawings after this date wl I void th;.= :F.cceptance and will require a resubmittal r. ri { : ;�.: - fix.:bsequent approval. efi yv; Final accep Nrnce is sujeCt to Held test and inspection by The Tukwila Fire Prevention Bureau. Date: By: SHEET NUM HOLLISTER - LANDLORD WORK Fire Permit Number 1 q- F -/Y-(1 To schedule inspections call 206-575-4407 SHEET TITLE FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON FA -01 SYSTEIV INFORMATION FA -02 TYPICAL WHIN G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FLOC PLAN Fl ALARM SHEET INDEX ADD NEW FIRE ALARM DEVICES TO AN EXISTING FIRE ALARM SYSTEM SCOPE OF WORK WISE SCHE DULE A\ D CO\ DUIT FILL CHAT WIRE DESIGNATIIN SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END EXPIRES 09/01/2020 FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE A_ARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE REORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMP_ETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDAI\CE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE INVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E E E E E 3 E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP ®E D DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD E DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE E WITH RELAY (EXISTING) HTRI-R SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM STROBE (EXISTING) SLSCW-F SIEMENS 4S BOX CEILING FIRE ALARM SPEAKER STROBE (NEW) SET -MC -W SIEMENS 4S DEEP W/ 1-1 /2" EXTN 80" A.F.F. TO BOTTOM TENANT [0,_ J -BOX F.B.O. F.B.O. VERIFY IN FIELD �w A END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND ii �. NORDSTROM 3 LEVELS .71,275,1 z:E HOLLISTER -LANDLORD WORK 2800 :a:v> I.:ary I>.:, 3Asn ,mm, ml•ECTS-5 MAC :t °.r3 trx, RFs EratrIrl maty LEVELS 250:4070 '1£ =71 lE71 .J OE TAE QRS G ` C ° fT ( L106TE7. JO0 5 RESTAURANT t. At -P PAT... WIRE DESIGNATION GENERAL NOTES SITE PLAN ROW irC • 3 7.1 RELEASE/REVISIONS REV. BY: 0 m ce DESCRIPTION I SHOP DRAWINGS DATE L07/26/2019 2aaaaa JCPenney lIFEE5 3 LEVELS . 276,46Rsf PAID III= 3 1 2019 TUKWILA FRE C-6 f 2a) SCALE: NOT Z 0 0 z N )-1 TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 07/26/2019 BACKROUND PLAN PROVIDED BY: V \0B NUMBER:46595-1} SHEET FA -01 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 12OVAC-6OHZ -{ DEDICATED EMERGENCY FROM EXISTING MAIN FACP C CABLE C' CABLE �`a a GRD N L - T T L -T- Id 0 PAD -3 0 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAPA AUX 1+ - 1 2+ 2- 2 NC C NO + - + - + - + - + - S 0 1_(2111),1_ql ® M 3.6k EOL 00 0 a 0 0 (-) (+) (-) (+) HARD LID CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE NAC S4 NAC S3 NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4 SQUARE BOX CEILING MOUNTED SPEAKER/STROBE '00 00• O°p o°o o SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) STROBE SPEAKER (+) (-) FROM PREVIOUS ADDRESSABLE DEVICE TBI CX 10 NO COM NC 2 TO FAN SHUTDOWN EOLR 470 SWITCH + - INPUT LED TSM -1 00 00 0 TO NEXT ADDRESSABLE DEVICE m e Is 2 3 5 0 0 NO ® COM HTRI-R NC O 0 Oj TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (-f) STROBE SPEAKER (+) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: U m ct DESCRIPTION SHOP DRAWINGS DATE 0) 0 N CO N N. 0 u) J *.Z.0 W 0 s` zco z Occ (75 cc� I- Q O0 O _J < !•-- C� w2z `f) z< 2w� tr U CC W 0� uI-- _ O .1 8 .J N �- 0 = J U (SCALE: NOT TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 07/26/2019 BACKROUND PLAN PROVIDED BY: \OB NUMBER:46595-1i SHEET FA -02 FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project: HOLLISTER - LANDLORD WORK Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLY Date: July 26, 2019 Module/Device Qty Standby Total Standby (mA) (mA) Alarm Total Alarm (mA) (mA) Power Module 1 15 15 0 140 140 0 A TOTAL FIRE ALARM POWER SUPPLY 15 140 B Auxiliary Device Current 0: 0 C Notification Appliance Load (Max. Total / mA) 0 D E F G H J K 2418 Total(A)= CALCULATION 15 Total(B)= 2558 Total current ratings of all devices in system (line A + line B + line C) 15 2558 Total current ratings converted to amperes (line D x .001) 0.015 2.558 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.2130814 Add lines G and I Total Standby and Alarm AH 0.5730814 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.68769768 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP -HR *** Notification Appliance Circuit Detail PROJECT: HOLLISTER - LANDLORD WORK Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPL Date: July 26, 2019 Wire Resistance 2.58 CURRENT TOTAL= 2418.00 NEW 3 SET -MC -W @15cd SLSPSCW-F @30cd SLSPSCW-F @75cd SLSPSCW-F @95cd EX 12 SLSCW-F @15cd DEVICES 15 98: 294 58 171, 256 40,. TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage 0 0 0 320 614 14 420 22.67 (WL* 2 )*(R/ft) (Total Cct Load) (E=I*R) 24 - E) 614 2.17 0.61 1 22.67 EX EX 3 EX 2 SLSPSCW-F @15cd SLSPSCW-F @30cd SLSPSCW-F @75cd SLSPSCW-F @95cd SLSCW-F @75cd DEVICES .6 EX EX _ EX EX 40 58 171 256 40 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I)_ Voltage Drop ( E ) EOL Voltage 174 342 0 0 556 14 396 22.86 (WL*2)*(R/ft) (Total Cct Load) (E=I*R) 24-E 556 2.04 0.56 1.14 22.86 2 SLSPSCW-F @l5cd 1 SLSPSCW-F @30cd 2 SLSPSCW-F @75cd 3 SLSPSCW-F @95cd SLSCW-F @15cd DEVICES 8 ... _ 40 58 171. 256 40 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 80 58 342 768 0 1248 14 384 CALCULATIONS 21.53 (WL*2)*(R/ft) (Total Cct Load) (E=I*R) 24 - E) 1248 1.98 1.25 2.47 21.53 Notification Appliance Circuit Detail - VOICE PROJECT: HOLLISTER - LANDLORD WORK Panel: SPEAKER CIRCUIT IT Date: July 26, 2019 Wire Resistance 2.58 CURRENT TOTAL= 7.08 SLSPSCW @1/4-W SLSPSCW @1/2-W SLSPSCW @1-W SLSPSCW @2-W SLSPCW @1/4-W SLSPCW @1/2-W SLSPCW @1-W SLSPCW @2-W DEVICES .2 3.54 7.08 14.14 28.29 3.54 .. 7.08 14.14 28.29 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 7.08 0 0 0' 0_ 0' 0 7.08` 14 24.00 (WL*2)*(R/ft) (Total Cct Load) (E=I*R) 24 - E) 7.08 0.00 0.01 0.00 24.00 TO EXISTING HOLLISTER FIRE ALARM 2S,2 bV 2S,2V J EXISTING TENANT J -BOX S1-1 15Cd 11W 2S,2V 2S,2V b b S1-2 15Cd 1/4W S1-3 15Cd 1/4W SINGLE LINE DIAGRAM EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1Z Lu ca 0)4Jizt 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I U m DESCRIPTION SHOP DRAWINGS DATE 07/26/2019 aaaaa Iflo�°° EQ° o0Jo c J < ,;l-- � wiz Zw= cc CC w F- CO Li_ 01-- J o N O CC 0 0 W z W J 0 z (7 C,) z 0 U U W F- C/) C!) SCALE: NOT TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 07/26/2019 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 46595-12 C SHEET FA -03 S1-3 15Cd 2S,2V 2S,2V S1-2 15Cd 2S,2V S1-1 15Cd 12S2V TO EXISTING TENANT J -BOX El L ( N, FLOOR PLAN - FIRE ALARM EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS !REV. BY: RBC DESCRIPTION SHOP DRAWINGS DATE 07/26/2019 2 <<<<< (41 CC 0 co W z co 0 o crE <0) a CLZ 0-10 _1 < t; o 2 2' Lij z ci) l—zu2c w cc 0 CC w < w cc c„), IJJ LL 0 }— cocm 0 0 0 LE: 1/8"=1'0" DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE:07/26/2019 BACKROUND PLAN PROVIDED BY: .10B NUMBER:46595-1i SHEET FA -04 Without Cornrrients As .Noted- in : Red Pet- The Attache Letter plans have i eenni reviewed by The Tukwila Fire <:. •*_ration Bure uva;th currery nt.Ci •c'rds. Acte rG'•li' %. s3fl)ect:. to t -cars and :•-. ir, signs which orf Not v nlatinns of.adoptad z' . 7-,rdard4 aria ordifnanc'e:3..:. `t iF responsibfiity _for -the -•• dequacy of design i=ce 5, otZT'i`t,h te dations: drtmirigs a fe this date wlitedd re a resubrnitt; ` o i - i i'.. approval _. Final,accedtar e It. , d o :� tc iCf.?E` t and Inspection.. 6.y Tne Tukwila Ffrt .?t sC°=-i Bufeau._. gate: Fire Pcrnit:Number /01 -S-TV V To se; eciule.irtpL:c loris coil 200-575-4407 a) i BRACE 1.4 P RETAINER STRAP WHERE REM -- IN SEISMIC AREAS TOP BEAM/ C—CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING Design per NFPA 13 - Ordinary Hazard 2 All materials to be new, U.L. listed, and F.M. approved All heads to be a minimum of 6' apart and to be unobstructed by any means 0 12 - Add Globe Model GL5601 Quick Response 155° Chrome Pendents 1/2 x 1/2 12 - Total STEEL JOIST/TRUSS HANGER DETAIL NTS ' a Corrugated stainless steel hose with stainless steel braid available in 2', 3',4',5' & 6' Iegnths . • . • Multi -Port Bracket • • Adjustable Hub - • Flexheacl ommercial Ceiling Unit T -Bar Ceiling Installation - Model #2024,2036,2048,2060,2072 df, ill11111XXIOX IX I. w FIRE PROTECTION SPRINKIItR ffiY$TE MB' . John: Thomes.DeMartirw - , 9794-1O$1-.CGLeVe13 • ' a.. Crawn.Fwe Protecitan; Inc. CROWNFP044LL," X 3 FIRE PROTECTION INCORPORATED P.O:. BOX 12113 -: MILL CREEK, WASHINGTON 98082--0113 PH. (425) 481-7669 • Hollister Westfield Mall 857. Southcenter Mall Tukwila, WA DATE: 7..2_ 200 DRA SCALE: ..1).:9:=A., l SHEET \ UM 3E� SHEET TITLE FIRE ALARM SYSTEM ADDITION TU ILA, WASHINGTON FA -01 SYSTEM I\FOMATIO(\ FA -02 TYPICAL WIRING AND MOU\TI\C DETAILS FA -03 SYSTEM CALCULATIONS A\ D SINGLE LI\E DIAGRAM FA -04 FLOO PLA\ FRE ALARM SHEET INDEX ADD NEW FIRE ALARM DEVICES TO AN EXISTING FIRE ALARM SYSTEM SCOPE OF WORK WISE SCHEDUL AN CO\DUIT FILL CHAT WIRE DESIGNATION 0 M 0 SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1 /8" .60 SQUARE INCH 1-1 /2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END EXPIRES 09/01/2020 WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE A_ARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (" FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY 3 3 4 SYMBOL DESCRIPTION MODEL y! Without Comments jo As Noted in Re4. ❑ Per The Attached Letter -,ese plans have been reviewed by the Tukwila Fire :Mention Bureau fol conformance wilt current City ,dards. Acceptai(:' iF Subject to errors and disslons which do hoc ,u-horize violations of adopted 3ndards and orriinancO_-. The responsibility for the degUaCy of design f:Ot:raitiv with the e signer. Additions, deletions or i,3vIsions to these drawings after this date will void this acceptartai and will require a resubmittal of revised drawin s it,- subsequent approval. Final acceptance is sub.'s to field test and Inspection by Date: 7 -/ /-j By:. sl l Fire Permit Number )9-F-/37 To schedule inspections call 206-575-4407 MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD 12 STROBE FIRE ALARM SLSCW-F SIEMENS 4S BOX CEILING 14 FIRE ALARM g SPEAKER STROBE E SLSPSCW-F SIEMENS 4S BOX CEILING DE TENANT J -BOX F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 71 275sf 1 L' HOLLISTER 857 V. StR ZT]. n•FE.ESS uaR W ? STY! S SEARS TAIL c �.-r.tmrn.F Efil .; R , SiaJ!Z S 0 tlY,__7 1 ▪ T505 Y 4'5 .5FSi.t�R T ▪ .-C6-.V iHR 1,.:0/1:T FILPAP. ` D ..GIFT: .Ent. ,95 - l JCP• enney . • C.LF5 3 LEVELS 776.46Rs` s F_S T 4J.'Si\ FESTA:tit:- 1 T` PAn, P011,) SITE PLAN PAiD itiN 2/ tillq TUKWILA FIRF 31/ l+L rr) co 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I 0 M 0 DRAWN BY: D. GARCIA DESCRIPTION SHOP DRAWINGS T. QUAALE DATE:06/26/19 U DATE M nonilikinrD.7M-1/10_1 N N 0 2aaaaa o O � T cc o 2z 0 0 W QW� I -U ZZ i DocII oa cc co 0 LL I- ›ffi % rY,ALt: NW 1 U SCALL ` DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:06/26/19 U BACKROUND PLAN PROVIDED BY: nonilikinrD.7M-1/10_1 N Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 }k THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120YAC-60NZ - DEDICAIED BBRGENCY FROM EXISTING MAIN FACP C CABLE C' CABLE Q N C IX T 0 PAD -3 0 0 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 S 0 e u e ISI uuuuu1-9-JM G H 3.6k EOL 0 0 (—) (+) (—) (+) HARD LID CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE NAC S4 NAC S3 j NAC S2 j NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4 SQUARE BOX CEILING MOUNTED SPEAKER/STROBE '°O 00• °°0 0°0000 SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) (+) ) STROBE SPEAKER (+) (—) FROM PREVIOUS ADDRESSABLE DEVICE 2 HFP-11 TBI CD® OOTT@ 1000, NO COM NC TO FAN SHUTDOWN EOLR 470 o SWITCH + INPUT LED TSM -1 0 00 TO NEXT ADDRESSABLE DEVICE 0 //i// 2 3 5 D0 HTRI-R 0 NO B COM B NC ® ,s\° o O� TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (+) ( ) STROBE SPEAKER (+) (-) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved rn Co Cr ASHINGTON 1743 1ST AVE. SO., SEATTLE, FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: M 0 DESCRIPTION SHOP DRAWINGS w\ I- o\ 0) 0 0 CO Z O CO O) LC ©20 W < WI--- C3 W z (O„) (/) = cc g0CC CO� W LO LL I�— SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:06/26/19 BACKROUND PLAN PROVIDED BY: \OB NUMBER:38009-1J SHEET '' FA -02 J FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project: HOLLISTER Panel: NEW BPS PAD -3 REMOTE POWER SUPPLY Date: June 26, 2019 Module/Device Qty Standby Total Standby Alarm Total Alarm (mA) (mA) (mA) (mA) Power Module 1 15 15 0 140 140 0 A TOTAL FIRE ALARM POWER SUPPLY 15 140 B Auxiliary Device Current 0 0 C Notification Appliance Load (Max. Total / mA) 0 D E F G H J K 2124 Total(A)= CALCULATION 15 " Total(B)= 2264 Total current ratings of all devices in system (line A + line B + line C) 15 2264 Total current ratings converted to amperes (line D x .001) 0.015 2.264 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.1885912 Add lines G and I Total Standby and Alarm AH 0.5485912 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.65830944 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP -HR *** Notification Appliance Circuit Detail PROJECT: HOLLISTER Panel: NEW BPS PAD -3 REMOTE POWER SUPPLY Date: June 26 2019 Wire Resistance 2.58 CURRENT TOTAL= 2124.00 SLSPSCW-F @15cd SLSPSCW-F @30cd SLSPSCW-F @75cd SLSPSCW-F @95cd 12 SLSCW-F @15cd DEVICES 12 40 58 171: 256 40 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage SLSPSCW-F @15cd SLSPSCW-F @3Ocd SLSPSCW-F r@ 75cd SLSPSCW-F @95cd SLSCW-F @15cd DEVICES 6 0 320 320. 14 360 23.41 (W L.* 2 ) * (Rift) .. (Total Cct Load) (E= I * R) 24 - E) 320 1.86 0.32 0.59 23.41 40 58 174 171 342 256 0 40 0 TOTAL mA= Total Wire Resistance (R ) Total Device Load Amps (I) Voltage Drop (E ) EOL Voltage 556 14 396 22.86 (WL*2)*(R/ft) (Total Cct Load) (E- I *R)... 556 2.04 0.56 1.14 24-E 22.86 2 SLSPSCW-F @15cd SLSPSCW-0 @3Ocd SLSPSCW-F @75cd SLSPSCW- F @95cd SLSCW-F @15cd DEVICES 8 9i�4�ti the 40 58 171 256 40 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage 80 58 342 768 0 1248 14 384 21.53 1248 ( WL * 2 )* (R/ft) 1.98 (Total Cct Load) 1.25 (E=I*R) 2.47 24 - E) ' 21.53 CALCULATIONS FACP"A p Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 FDBZ492-HR 3 0.0635 0.0635 0.064 0.192 HTRI MODULE 0.00960 0.0096 0.021 0.084 0.0731 Amps 0.276 Amps Notification Appliance Circuit Detail - VOICE PROJECT: HOLLISTER Panel: SPEAKER CIRCUIT Date: June 26, 2019 Wire Resistance 2.58 CURRENT TOTAL= 74.34 7 SLSPSCW @1/4-W 7 SLSPSCW @1/2-W SLSPSCW @1-W SLSPSCW ®2-W SLSPCW @1/4-W SLSPCW @1/2-W SLSPCW @1-W SLSPCW @2-W DEVICES 14 3.54 7.08 14.14 2.8.29 3.54 7.08 14.14 28.29 TOTAL mA Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage 24.78 49.56 0 0 0' 0 74.34 14 24.00 (WL*2)*(R/ft) (Total Cct Load) (E=I*R) 24-E) 74.34 0.00 0.07 0.00 24.00 TO EXISTING SPEAKER CIRCUIT TO NEW BPS REMOTE BOOSTER POWER SUPPLY (FIELD LOCATE) 2V b 3S b S,V S S3-1 15Cd 1/4W S2-1 75Cd 1/2W S,V V S,V r S,V f S,V T S V y S,V y S,V S3-2 15Cd 1/4W S3-3 75Cd 1/2W S3-4 75Cd 1/2W S3-5 95Cd 1/2W S,V V S,V y S,V y S,V y S,V S2-2 30Cd 1/4W S2-3 30Cd 1/4W S2-4 15Cd 1/4W S2-5 75Cd 1/2W S3-6 S3-7 S3-8 95Cd 95Cd 30Cd 1/2W 1/2W 1/4W EOL S2 S2-6 30Cd 1/4W EOL S3 S1-1 15Cd S1-2 15Cd S1-3 S1-4 15Cd 15Cd S1-5 15Cd TO EXISTING DATA LOOP 2------�� EXISTING TENANT J -BOX D,I '' D,I D.I 21 '' 21 21 S1-6 S1-7 15Cd 15Cd S1-8 S1-9 S1-10 15Cd 15Cd 15Cd S1-11 15Cd SINGLE LINE DIAGRAM S1-12 15Cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved z c z 6Q cc z r0 CO 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE m co (N1 co O zco o Q0) cco �0 w < a- W(D W zz JUw 0 cc =�cn_ W cc cow it H a W z J W .J z CO z 0 SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 06/26/19 BACKROUND PLAN PROVIDED BY: ,JOB NUMBER:38009-L1 SHEET FA -03 TO EXISTING TENANT JUNCTION BOX & NEW BPS BOOSTER POWER SUPPLY \ S,V s,v D FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED; BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. z ADJACENT TENANT SPACE N.I.C. LAYOUT POINT LAYOUT POINT EXIT HALL 111 I S3-1 15Cd 1/4W S3-2 15Cd 1/4W 6in_ '/////dB' ®!/////////////////////////// /////////////////////////dam//////////////////////////!///!//i // ///JU////////////////////.b' .®U/ =III1i' I I MN I BiM1 M 2 E rinki S1-2 15Cd MEN'S GUY'S #2 109 GUY'S 1 103 S3-8 30Cd 1/4W t PROCESSING BENC-- 17 /Alf L LOUNGE S,V 105 1 STOCKROOM 114 S3-6 95Cd 1 /2W S3-7 95Cd 1/2W 18 GIRL'S 1 104; S2-6 30Cd 1/4W GIRL'S #2 109= I I I I i % i//oiiA %'il/iii//i////l/////\�// /////ii: ///�//////////r///////.ri/////.e .s fir./ /%///////////zee/Ay M2 M2 S2-2 M2 M2 M2 S2-3 M2 30CdTTING S,V 30Cd FI 1/4W g 110 © 1/4W S1-11 r= .�-� ,., I I. j!F.R.'�'4' R 9PI ALCOVE I / 10 ., z: , .. t a., .mei ..: G1011 -17 L F %- I.!' (L1L 11.1_' �' LL. t' L !. i i S1-3 �- S1-4 � S1-5 � S1-6 � S1-7 � S1-8 � M 2 15Cd M 2 15Cd� 15Cd 15Cd 15Cd'a / M2 M2 M2 M2 / M2 f l/o////////////////�////%/%iv .r///I/////oo//////////////m////////////////////�/i/�/.///%/ //.�///////////////����/moo/// ////////////////�////////////.I./��///�/�//////���/i////.o.G;o,E', , %,, v //r //ofes _. - -. _ _ //o//i/fi//; ii ///iii�i//� S,V GIL BALL 5- LV1NG S1-9 m2 15C. G1 ADJACENT TENANT SPACE NJ.C. FLOOR PLAN - FIRE ALARM 6 EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE rn (0 N CO O 2aaaaa 0 0 LL SCALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 06/26/19 BACKROUND PLAN PROVIDED BY: ,OB NUMBER:38009-1j SHEET FA -04 NEW CEILING TILES AND GRID. NEW CEILING TILES AND GRID REFLECTED CEILING / LIGHTING PLAN 1/4" = 1'-0" • FlexHead Sprinkler Drop . l,:,%:� .. Cohugated stainless `%`'`'��,- steel hose • / ile in with stainless steel brai ViP Multi -Port Bracket • • • • • Adjustable Hub Flexheadr ommerdial Ceiling Unit l -Bar Ceiling Installation Model #2024,036,2048,2060,2072 RETAINER STRAP WHERE REQUIRED IN SEISHIC AREAS TOP DEAN/ C-CLAHP WITH SET SCREW 3/8' ALL. THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS ❑ Without Comments ❑ As Noted -i= t Rei' X. Per The Attacne. Letter These plans have been reviewed by The Tukwila Fire 1'revention Bureau fou conformance with current -City tandards. Acceptance is subje t to errors and omissions which do recti authorize ,-solations of adopted ttundards and ordirlences: The resporsibiliry for the .dequacy of de: i{: , ; Cts totally with the (3esigner.. ;Additions, deletions revisions to these drawings after this date will void c..._ acceptance and will require a. resubmittai of rev.,`,: d_awings for subsequent approval. Final accepta: is f:.-.7,10 ' to field test and Inspection by • The Tukwila Fire : ie.:.-.;.3i,rgau. Date: 7 - I • S(I Design per NFPA 13, Ordinary All materials to be new, U.L. listed, and M2 All fire sprinkler heads to remain unobstructed F.M.ed approved All heads to be at least 6' apart by lightings, ceilings, or any other means ®ss®siosw ssrassss PsassesCERTTIITIOrriPNCYFIRE PROTECTION SPRINKLER p 8 John J. Abel r �sCrotvn Fir , at b/mi/mitmifmmm slssssrsrsssssrj no. • 1 — Add Reliable Model G5-56 Standard Response 165° ° 4 —Relocate Reliable Model G5-56 Standard Res ons Concealed Pendents % x 1/2 o 1 — Plug existing p e 165° Concealed Pendents % x 1/2 (Flexhead s) a 5-575 O7 and i:va this Fire Permit No. /1/45--S - O7?-• i'or shut- down of approval. MALL SITE PLAN CROWN FIRE PROTECTION. INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Hollister Westfield Mall 857 Southcenter Mall Space 1440 Tukwila, WA PA 8 2015 - L �F�F P AP 2 TUKWIL 45-75" DATE: '-1 sL%o is DRAWN: cAl- SCALE: I 1 nC LLI � FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON P' Without Comments o As Noter: in Ree O Per The Atcacrie Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformance with current City - - ndards. Acceptance is sun}ed. to errors and 1nissions which do not authorize violations of adopted :�ndards and ordinnces. The responsibility for the 1equacy of design rests totally with the designer. .additions, deletions or revisions to these drawings after :his date will void this acceptance and will require a esubmittai of revised drawings for subsequent approval. sinal acceptance Is subject to field test and Inspection by the Tukwila Fire Prevention Bureau. Date: `S_ " /sem By: /411'N 51 i c:iva E.. : ;.� 1; THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' VIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-601Z —{ DEDICATED EUERCENCr FROM EXISTING MAIN FACP C CABLE C' CABLE 0 ujL Q N LO MOO U CI 0 PAD -3 00 INPUT INPUT TRS NAC1 NNC2 NNC3 NAC4 Aux 1+1- 1 2+2- 2 NC C NO + - + - + - + - + - 0 s e e o A 3.66 EOL 0 0 (-) (+) (-) (+) NAC S4 WAC S3 NAC S2 NAC S1 EXISTING POWER SUPPLY WIRING DETAIL COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING 0 HARD LID CEILING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE -(+ FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL 0 END OF LINE DEVICE(3,6K 1/4W) 0 SUPERVISED SWITCH GROUND N) 0 HTRI-R OSTATUS LED 0J 0 0 0 N.O. COM N.C. HARD LID SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V CABLE) 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. MUSIC (+) (-) STROBE SPEAKER (+) (-) 1+) ( ) STROBE (+) ( ) STROBE SPEAKER (+) (-) n 4 -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4.OA @ 125VAC) (4.0A @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL SPEAKER STROBES & STROBES ONLY WIRING DETAIL FROM PREVIOUS ADDRESSABLE 2 DEVICE 2 TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS HFP-11 TB1 @®®() Y Y O 00 NO COM NC 2 TO FAN SHUTDOWN EOLR 470 HTRI-M RED BLK ORG ORG GRN + TO NEXT a _ ) ADDRESSABLE DEVICE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL DUCT DETECTOR/HTRI-M MODULE/TSM-1 SWITCH WIRING DETAIL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN¢ TEMPERA RE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-9333% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > DEVICE IS USIED FOR AIR VOLOCITY APPUCAIIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION 1IMMTH DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 / STANDARDOKE SM DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT 0 0 0 0 > TO NEXT ADDRESSABLE DEVICE TO NEXT DEVICE CADDY BAR �l �f SMOKE DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2015 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS r T Z co O w ,- Vg p �Z W d Jo I- W CZ JU)wC�C OJ�z� w W = LI- 0I_ I` co CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/23/15 BACKROUND PLAN PROVIDED BY: 10B NUMBER:12021-1J SHEET i SWITCH + — INPUT LED TSM -1 HTRI-M RED BLK ORG ORG GRN + TO NEXT a _ ) ADDRESSABLE DEVICE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL DUCT DETECTOR/HTRI-M MODULE/TSM-1 SWITCH WIRING DETAIL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN¢ TEMPERA RE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-9333% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > DEVICE IS USIED FOR AIR VOLOCITY APPUCAIIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION 1IMMTH DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 / STANDARDOKE SM DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT 0 0 0 0 > TO NEXT ADDRESSABLE DEVICE TO NEXT DEVICE CADDY BAR �l �f SMOKE DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2015 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS r T Z co O w ,- Vg p �Z W d Jo I- W CZ JU)wC�C OJ�z� w W = LI- 0I_ I` co CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/23/15 BACKROUND PLAN PROVIDED BY: 10B NUMBER:12021-1J SHEET i A B FIRE ALARM BOOSTER POWER SUPPLY BATTERY Project: HOLLISTER CALCULATION Alarm (mA) Total Alarm Panel: EXISTING BPS PAD -3 Date: April 24, 2015 Module/Device BOOSTER Qty POWER Standby (mA) SUPPLY Total Standby (mA) (mA) Power Module 1 30 30 0 30 30 0 TOTAL FIRE ALARM POWER SUPPLY 30 30 Auxiliary Device Current 0 0 C ' D E F G H I J K Notification Appliance Load (Max. Total / mA) 0 5711 Total A = ' 30 i Total B = 5741 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 30 5741 Total current ratings converted to amperes (line D x .001) 0.03 5.741 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.72 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.4782253 Add lines G and I Total Standby and Alarm AH 1.1982253 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 1.43787036- 12 V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 PROJECT: HOLLISTER Panel: EXISTING BPS PAD -3 POWER SUPPLY Date: April 24, 2015 Notification Appliance Circuit Detail Wire Resistance 2.58 CURRENT TOTAL= 5711.00 1 SET -IAC @15cd NEW 3 5 SET -MC @30cd EX SET -IAC @75cd EX SET -IAC -CW @95cd SET-IAC@l5cd EX ZR -MC -CW @30cd DEVICES 11 69' 111 200: 64' 11 TOTAL mA=, Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) r • EOL Volta 69' 222 600 0 320: 0 1211; 14 350 21.81 1211 (WL*2)*(Rift); 1.81 otal Cct Load) 1.21 = I * R) 2.19 21.81 SET -MC -CW @15cd 69 i 0; SET -MC -CW @30cd 1 SET -IAC -CW @75cd 200: 0 SET -MC -CW: @95cd 264 ZR-MC-CW©15cd 69 0 ZR-MC-CW @3Ocd .,- ' 111 0 TOTAL mA= 1500: 14... 24.00 DEVICES 0 :Total Wire Resistance (R)) 7otat l evice'Load, Amps (I) Voltage Drop (E ) EOL Voltage 1500 WL*2)*(Rift) otai Cct Load} l(E=I*R) :4-E) 0.00 50 0.00 24:00 DEVICES SET -MC -C SET MC -CW -@30c SET -MC -CW @75cd 200: SET -MC -CW @95cd SET -1/1C -VV 6110cd M -ZR -MC -CW 3ocd 0 TOTAL mA=: 1500: 14 ;Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E EDL Voltage (WL*2)*(Rift)! li Cct Load) E= I * R) 24 E 1500 0.00 1.50 0.00 24:00 DEVICES SET -MC -CW @15cd 69 0 SET -MC -CW @3Ocd 1 SET -MC -CW @75cd 200: 0 • SET -MC -CW @95cd 264 SET -MC -W @110cd ZR -MC -CW tcii30cd 0 233: 111 TOTAL mA 0! 1500; 14 24.001 1500 Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage CALCULATIONS (WL*2)*(Rift): (Total Cct Load) I(E=1*R) 24-E) 0.00 1.50 0.00 24.00 TO OTHER EXISTING , NAC DEVICES TO OTHER EXISTING NAC DEVICES S,V 75cd SINGLE LINE DIAGRAM 15cd 75cd FIRE ALARM NOTE: ALL SPEAKERS TAP TO 70 -VOLTS 1/2 -WATT. t) ao 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 0 T Z loo OW SS I_ Q rn I owQ W d J O ~ W ¢Z Jcow< Qacz. = Dog W CC D L- OI— i` U) co �CALE: NOT 0 0 W z W J 0 01) C!,) Z 0 U U DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/23/15 BACKROUND PLAN PROVIDED BY: .OB NUMBER:12021-1i Proprietary and Confidential, Copyright 2015 by Guardian Security Systems, Inc. All Rights Reserved \ SHEET FA -03 EM (E) EM TO OTHER EXISTING NAC.. DEVICES SV EX �- A-23 75cd o-S,V EM (E) 15cd EM (t) • S,V ll 1 1 1 1 ,1 (R) TO OTHER EXISTING NAC DEVICES S EX 75cd EM (E) EM i EM (RT\ ENt ITYJf . (E) 5 EM (R) A-1 (TIE) 1' 1 FIRE ALARM SYSTEM PLAN SCALE: 1/4" = 1'0" FIRE ALARM NOTE: ALL SPEAKERS TAP TO 70 -VOLTS 1/2 -WATT. ELECTRICAL PANELS AREA OF WORK KEY PLAN SCALE: N.T.S. Proprietary and Confidential, Copyright 2015 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 1 DMG I DESCRIPTION SHOP DRAWINGS DATE 04/23/15 2 CCCCC 0. O zoo �- O w7""" CCta (I) W < Jo Ns L_ C J� V w aC C O �z� C Cwj g cCw F- CC I -01— I` co W cr -CALF: AS NOTED DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/23/15 BACKROUND PLAN PROVIDED BY: SOB NUMBER: 12021-12 SHEET FA -04 FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYTEM FA -04 SITE PLAN, SYSTEM CALCULATIONS (GENERAL), RISER DIAGRAM WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR #16 FPL/FPLR RED (JACKET). V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED .#18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS : AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2' 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY. HAVING JURISDICTION. 5.. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. DETECTORS SHALL .NOT BE MOUNTED IN DIRECT - AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO. CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN. ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR 'ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10: THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH. ARTICLE 725 AND 760 OF., NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE. TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUVTED: AT A HEIGHT OF 80" A.F.F. OR 6". BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL. PANEL NUMBERS AND CIRCUITS WILL BE QN THE RECORD .DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15:: PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES: SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE 'ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. i 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2002 6.4.2.2.2 ALL STYLES OF CLASS, A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2002 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS -305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 1 1 6 11 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARAI FIRE ALARM SDD-C SIEMENS REMOTE ANNUNCIATOR PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP ® INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D I DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD 111 CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD ISN LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD ® SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP. W/ .1 G RING CEILING DUCT SMOKE ®D. DETECTOR AD2-XHR W/ SIEMENS HFP-11 DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING 2cC FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING FIRE ALARM SPEAKER . STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1 /2" EXT. 80" A.F.F. TO BOTTOM c FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U_0_N. Q C FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX W/ 1-1 /2" EXT. 80" A.F.F. TO BOTTOM FIRE ALARM B p STROBE WP (WEATHERPROOF) SET -S17 -WP " SIEMENS MT -SUR -BOX 2" PIPE VERIFY IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FATC FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A. N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A Wthout Comments As Noted in Red Per The Attached Letter I nese plans have )lien reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceprance is vuniect to errors and omissions which du not authorize violations of adopted standards and or -at -lances. The rr~;'cnsibR :,vforthe r adequc':y O` CI; tOt.E`t; ;y .; r , !he designer. .,:finer. drawings atter ti 7 „ :i U require a r �u rtll't�i of r evil G; .;'!1!i:y5 to cubbequent approval. ;neJ ac'v%p iar tce i:.,ubject to fic !d test and inspection by The Tu'rwila Fire Pi evention Bureau. IDate: y �� By: GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A TUKWILA FIRE DEPARTMEn Please call: 575.440Z and give this job No. OY-F-/0c1 and exact address for shut' ouwn or restoration approve; NOTICE A otnp°ems, signed, Tukvviia Fire Department Pre-test Certificate must be presenter! to the Inspector prior to commencement of Acceptance. Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. -Ztis�w�l Ioc,k o A• ded; 44441 FA -5Y) .- Syy •�. #u cok.PI)/ 'u(. Mr -PA 72- �.o0eal -1-, Copyright 2006 by Guardian Security PA I - 2008 Tukwila Fire 7-25-21 72/ Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS r m LU DESCRIPTION 0 0 2 C �CALE: 1/8" = 1 DRAWN BY:.': (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/19/08 BACKROUNDPLAN PROVIDED BY: ,OB NUMBER: SHEET A-01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTAL_ LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AIR DUCT 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT pat SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE`—/ o END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH GROUND 0 0 —0 © © HTRI–R STATUS LED CO DUCT DETECTOR LOCATION N.O. I` 0 cD 0 CDM N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 0 TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCAB (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE L - + NOTE 1; VOLTAGE MAX. - CURRENT MAX. - CONT. RES: MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD)- MAX. LINE SIZE- i MIN. LINE SIZE - MUSIC OUTLET SAMPLING- •\ TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE LII -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE I DEVICE LOOP .I 0 `FROM'; SLS CONTROL PANEL OR 01> 1 PREVIOUS ADDRESSABLE DEVICE (-)> TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE (-) , FROM XLS CONTROL PANEL OR {(¢) PREVIOUS ADDRESSABLE DEVICE (-) RELAY CONTACTS (4.DA a 125VAC) (4.0A a 30VDC) 27 VDC 3.5 mA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF . 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. TB1 L�0000 .2-3.4.5 6 HCP TB2 00 65 END OF LINE M DEVICE 7 D 0 (3.6K 1/4W) SUPERVISED 1 SWITCH GROUND / / / 0 0 © 0 HTRI–D STATUS LED 00 0` NOT USED 0 END OF LINE DEVICE 0 . 3.6K 1/4W) 0 NOTE:. FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL WEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) - 0 GND N AC DIDID 0000 U n 0 PAD -3 0 0 O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1-- 1 2+.2— 2 NC C NO .+ .— + . —-- 111 PI DJ 11111M 11113211341113011m 24K TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE SUPERVISED "WITCH NAC -4 NAC -3 NAC -2 NAC -1 470 OHMS iW EOL 0 p 0 INPU (4) sI TS ca M-1 0 as gel o~ LRN 1.6 z g ONO gc°' m00 0 L2 3A 5_. WSW TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL FROM REMOTE POWER SUPPLY ('S' CABLE) FRI FACP (VOICE CIRCUIT) C'V' CABLE) SCIE: NONE EARTH GROUND _>(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE C (STROBE) SPEAKER O ) STROBE C'•� (+) (-) STROBE SPEAKER SPEAKER/STROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY R E BO- 4S 'DEEP. BOX W/ 1-1/2- EXTENSION RING' (SPEAKER STROBE) 4S BDX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALEJONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NO1E: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN 1 RA +32' F (0.0 TO 100' F C .) UMIDITY; 00-- X RELATIVE HUMI TY. NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POKER SOURCE DATA IN (-) >— DATA IN (+) > MACE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FTAIN *JEN USED IN CONa1NC11ON 1M11 DUCT HOUSINGS AD -11P OR AD-11XPR _.....____.s...\.\\s.\\ Lt BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL IABB. SCALE ( ) DA (+) DATA OUT TO NEXT DEVICE > DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID --- CEILING HARD LID -_\ SPEAKER SUPPORT T`E BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION N. CEILING MOUNTED -- SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTI❑N BOX - MOUNTED ON CEILING FLEX \ JUNCTION BOX -- --t MOUNTED AGAINST CEILING SUPPORT II O 0 TO NEXT DEVICE O O CADDY BAR SMOKE DETECTOR—' SMOKE DETECTOR MOUNTING SCALE=NONE ri • ht 2006 b Guardian Securit '--- SUSPENDED ILLUMINATED CEILING S stems, Inc. All R. • hts Reserved 743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS LU DESCRIPTION LU F- 1 co co ccO) w <0 W - U)�wz cc W Q o 5' 0 1-12E- - �o5 LC) a0 i -- /SCALE:1 /8"=1 DRAWN" BY: (-ANDERSON DESIGNED BY: R.VEZZANI DATE: 3/19/08 BACKROUND PLAN PROVIDED BY: �OB NUMBER: SHEET FA -02 r 0 pci _11 -av,as- hi 2S 15 2S I. BPS • 2S,2V i=1 El 0 30 El 0 30 15 Cu ---------- -----_-_-_-_-__ ---------- ____ ---- S,2V 2V,S ----- ----- i • C) 2V,2S • • E. CU 5 Cu 30 11 TIT S2V,2 30 II Jq_ 2V,2S 30 EOL Si IC \V \ I _I_ Li. „Lr, El 0 30 El 0 30 ,,,, rp:-_---._ -__--- ____,. c•-.; \ \ 1 11 C 1 t. \ I , 0.----1 ; 1..-- 1.------- 1.------ :1Er iL -I \ ; : • : 15 NORTH HOLLISTER WESTFIELD SOUTHCENTER MALL SCALE 1113'Ll' ;1: • FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND. MUSIC INTERFACE. FIELD LOCATE SIEMANS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDLINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR, WIRED. BY ELECTRICAL CONTRACTOR. 1 Corwriaht 2006 by Guardian SecuritY Systems, Inc. All Rights Reserved• SCALE: 1 /8 =1, DRAWK! BY: LANDERSON DESIGNED BY: R.VEZZANI DATE: 3/i-9/08 BACKROBNB, FLAN PROVIDED BY: f . bE ; ----- EC] Y� 1465 I 1150 J uil 1 KIDS FOOTLOCKER 112001 U7 1430 I LL.0 '."1 N H (I I'3 14_ ;`- 11490.1 RE;.rL:p;r STSR;;E NORTH R:SFR ROOM ; i:'I'JP uOCK LJ rTh rn [1 ,r LL LL LSI 1215 r; 12,n 141 CI-I_ESE(:'.,,?\'__ TlACTOR `•`. R3__1 I HOLLISTER WESTFIELD SOUTHCENTER MALL ---- SCALE 1132'4 IA t F0011 OCS: ER U rT 23 ::n 0 (._;ALIF OP,NiA MAC GRILL EOL S2 v,s FA JBOX BPS 13,P 120 VAC FLOOR 1 v,s v,s O v,s © v,s O . v,s v,S 15 15 15 30 15 30 30 30 EOL Si :=LECTRI G!' Ll( sr},1 .. PIZZA KITCHEN 0,�' CO?,IPACTO <7 n SYSTEM CALCULATIONS HOLLISTER HOLLISTER FACP ADD ONS Current Load: SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations Standby: Alarm: Current Load: Device Type HFP-11 AD2-P Qty 6 Standby: Alarm: Amps 0.0022 Total 0.0022 Amps 0.0023 Total Device Type Qty Amps Total 0.014 Amps Total 0.0635 0.0635 0.064 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R HTRI-D 1 0.009600 0.0096 0.021 0.021 0.001600 0.0035 0.0731 Amps 0.021 SET -MC @15CD SET -MC @30CD SET -MC @75CD SET -MC @110CD ZR -MC -616-63- 214-mc 15CDZR-MC @30CD Amps HCP Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours 4 0.064 0.256 9 0.098 0.882 0.175 0.233 2 0.064 0.128 0.098 1 0.0015 0.002 0.03 Amps 1.2975 Amps Alarm Current Load: 0.021 Amps For 5 Minutes= 0.002 Amp -hours 25% Derating= 2.195 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.2975 Amps For 5 Minutes= 0.109 Amp -hours H Total System Current Load: 2.195 Amp -hours Battery Pair to bdi sed: 12VDC Amp -hours 7AH 25% Derating= 1.036 Amp -hours Battery Pair to be Used: Total System Current Load: 12VDC 1.036 Amp -hours Amp -hours 7AH xx>rfx RECOMMENDED MINIMUM BATTERY SIZE = 7.00 AriperexHours BATTERY SIZING CALCULATION Notification Appliance Circuit Detai% PROJECT: WESTFIELD SOUTHCENTER MALL Panel: HOLLISTER ' y Date: !April 3, 2008 CIRCUIT:: S1 ; t QTY }- Device Type (Alarm Current? Alarm Total Wire Size ? Wire Length 2 ISET-MC @15CD - I 641 128•1 Wire Resistance 3.24 CURRENT TOTAL= 1266 4 i SET -MC @30CD 981 392 O {SET -MC @75CD - 175i 0 233; O 1SET-MC @110CD - 2 = ZR -MC @15CD _. _ 1 128, • O ]ZR -MC @75CD. 175 0; i . O ZR -MC @110CD 2331 01 _.__ 0f Voltage at EOL Circuit Total ; yTotal Wire Resistance (R) ? 1.83! (WL w 2) (R/ft) • I Total Device Load, Amps (I) 1 0.65; i (Total Cot Load) -. 1 -- 'Voltage Drop (E) �- # (E=.I"'R) I • ; IEOL-Voltage . (20.4 E) DEVICES=i8 TOTAL mA-i 648 •.___ r. 12 1 282 i 19.215870721 648( ;CIRCUIT: • ; S2 i { ' QTY Device Type [Alarm Current, Alarm Total ; Wire Size 1 Wire Length ' Volta a at EOL t_Circuit Total # i 2 ?SET -MC 15CD 9 i 9 ._ 64 : 128 i I 5 SET-MC©30CD 490' I 0 16E. -MC @75CD ! o1 981 175i 233; O 64? O' 98; 0 175.s 0; ' 233! ..__.__. 0 t ; 0 ;S O ET-MC(_cD1 1 OCD , O --jZR-MC @15CC - ZR -MC @30CD 'ZR -MC @75CD O i ZR-MC©110CD 0 0 0 DEVICES={7 I TOTAL mA=j 618; 1 1.18; 19.22 t Total Wire Resistance (R) i 2.401 - _ . ( WL W 2 )/ (R/ft) ,Total Device Load, Amps (1) (Total_ Cct Load) IVoltage Drop (E ) (E= I " R) =EOL Voltage (20.4-E) 18.918283 1 6181 notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: HOLLISTER Date: April 3, 2008 Wire Resistance : 5:16 CURRENT TOTAL=; 27 CIRCUIT:!SPEAKER CIRCUIT QTY : Device Type #Alarm Current? Aiami Total Wire Size ` Wire Length -15 i70.7V1/8 ,_1 1.8 . 271 0 0 . DEVICES= 15 I 0. 0 01 �I TOTAL m A-- 01 0 01 01 27 12 1 � Voltage at EOL 1 Circuit Total r "Total Wire Resistance .(R) (WL*2)*(R/ft) - -;Total Device Load, Amps (I) (Total CO Load) VoltageDrop(,EY)� }EOL Voltage ' (20.4 - E) I s 570 ' 120.24117521 27 } 0.62 1.48 18.92; - 0.031 0.16 20.24 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 LLJ LU LIJ CO CI 0 LLI Ct 25 REVISONS LLI 0 co a, F=E6 CO 2 [L-1- f- lu] ffC LU LL DESIGNED BY: BACKROUND PLAN PROVIDED BY RISER DIAG SYSTEM CALCULATIONS Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER: SHEET FA -04 GENERAL LEGEND —P -4 O BOD BOB BOJ FOS FOW EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPUNG ( UNLESS NOTED ) CAP PLUG CENTERLINE HYDRAULIC REFERENCE POINT CENTERUNE PIPE TO BOTTOM OF DECK CENTERLINE PIPE TO BOTTOM OF BEAM CENTERLINE PIPE TO BOTTOM OF JOIST FACE OF STUD FACE OF WALL FOC AFF CH R.C. 4 E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR CEILING HEIGHT REDUCING COUPLING OUTLET COUPLING WELDED OUTLET 'AT" FITTING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALSO "Gr) THREAD/` 1T" (ALSO "Fir) ALL -THREAD ROD 10 :h9 8 Q/ F1/_ •elea Teeing uonueneid eJld eIIM){nI Gq t hq uol;oedsul pue peg o;;oo[gns sI eoue.daooe feu!_ •IenoJdde;uenbasgns Jo; s6u!melp paslnaJ;o Iel1!wgr.F- e aJ!nbai IIIM pug; aoueideooe s,(Ia pion fl;;r•, Jape s6ultre!p esaq; 04 suo!SIAOJ JO SOOF4010p •Jeu6isep ag; g11M Allem STsei ubisep eq; Jo; AImisuodsoi e41 •saauzu,oJo pue solEoue pa;dope;o suogeloin ezuoglne;ou op goiquat suolsslw pue SJOJJe o; Ice!tinQ sl eoue}deoov •spJepue; Apo luau= g;IM eOU WJJOtUO3 J0; neaJfH uol;uenaJd eJld eIW, Inl eql Aq paMalnei ueeq eneq sueld eseu I .>a1;al pegoelld 041 Jed pOH III Pe1eN eV sluau)Wo3;noq; ORL WERIF THIN 2111,4 III, J. ass I■ mroo#,T 'WNW 1 I 1 U tn 0 I 0 U FIRE PROTECTION NOTES FIRE SPRINKLER SYSTEM TO PROVIDE 100% SPRINKLER COVERAGE IN ALL AREAS PER THE STATE AND LOCAL FIRE MARSHALL WHENEVER POSSIBLE AUGN SPRINKLER HEADS WITH UGHT FIXTURES, AIR DEVICES AND TO CENTER OF 11LE. THE PATTERN IN EACH ROOM SHALL BE CONSIDERED INDEPENDENT OF OTHER ROOMS. ROUTE ALL PIPING AROUND ELECTRICAL PANELS. COORDINATE WITH ELECTRICAL CONTRACTOR. PROVIDE SPRINKLER HEADS GUARDS IN ALL LOCATIONS SUBJECT TO DAMAGE. FABRICATION, ERECTION AND TESTING OF AL PIPING SYSTEMS SHALL BE IN ACCORDANCE WITH OWNERS GENERAL REQUIREMENTS, N.F.P.A. #13, 24, 231 & 231C. AND LOCAL CODE & AUTHORITIES. SPRINKLER PIPES FEEDING COVERAGE BELOW STORAGE DECKS ARE TO BE FED BY ROUTHING ONES DOWN FULL HEIGHT WALLS AROUND PERIMETER OF DECK. FULL OPEN CLEARANCE OF STORAGE DECK IS TO BE MAINTAINED. rREMOTE AREA ORDINARY HAZARD GP 2 20 / 1500 S.F. J BASE OF RISER: 92.82 PSI / 504.2 GPM TUKWILA FIRE DEPARTMENT Please call: 575.4407 and give this job No, 02-S-07 Co 4, - and exact address for shuts down or restoration approval: MOTXCE Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic test approval. 0•X24• LANDLORD PLY AIR DUCT imirimimin 1 1' 1 Mill 0 ,tmiiiitttttt.ri,a"ttttr_ Ir--..f1i laillidelI '�a 1_�w�� jll.I EE11L:l �I�IIMID,, �w�1� I 'i■`ii ,� ■iL•1rr,.I� -;t■:■W„ 1�1= n r rm. ► -• _- -. ��I��Ifi I - IIE+. ■N�:. i 9 Iv IMMIllid _�I_IIu11EIifl -_ �r IEEiItI�s1■ i1i>i 111 ' $1111111111111111M111111111111ffiliti�C► , II cum I �lI■�7IIIm U v � IIID iftrirmumilliMINIIIIIMII111111111111•111111111111 oil i�. �'5iciammiiIiw �>1CD��imire Mair- I :11710v.ormilumniornomillii,�' " E■1111r 1111111. ��i POIDE7 ET: -11PriX1 I aiiil 11111/ 1►:1-a11n I I I Ma i ■!IEC EIII1111$,I • , u�IB- 1„• t•m �iwtt:] �■i ,:I lei :..MOD �I ,Jl.MEMEMI_t11 J55 ���!►I,.. lfs:o. till I wi�i I■�w■1,_=I or tzl11111/ . Ir r ■s ■�Illl Ir..'.Mag14 MINIM lit...1111MI OM Ipf� ���I � i� ��_IIr ai=F!'IllisiI IillliniimilliI.Iiiiiiiiiiii''Ir, .,� iiailr � c fir! � ,r . !moi 11l A1P11 INN= 3�tl�:� � --.::--= Y�_ ji.� ..�■eN■rvw�ii �":�� !; ��r �. ■I!,4 it IE.� Q,IZ IMMI t x��0 4, 11111111111111011111111,1111011_ IIPPINE_IPUUUUU ra ,EEEEEE1111 Illi EE 11�i � 11. l ill I'����niiisiiiiiampqmomm III 11 'lea 111111110011E01111E131 �fiii�� �t����..-is>_rtw��t►vtc:�.ar�� IIiI 1 . ��E� EwE11111111E1EEEEEI 11!`”: "'re,MI ss>17741,1I �L a�L��1��EryiWJ����. --. i E 1E..... 9112 E12EIi 1r��c I `, •,...,....,.........„- i ....`..�■I.rn...- •I171:�; t I............,.. IEEE ilI inteJ IIIIEEEEI�bilimiii )111.171■, . .>�W� ��1E'9IL � :soma I�1�1I1��1,�-'1iiI I R UIi iit_I ILIIRIL U1t 11tiIii iiik iiiI i #mI _ ES.. iE_iIEIENEil■�i 1 �.•_ �j EI z--� ...I�Dhir'r'' Irma. luiliK AMIE `hall` all 1411117 .ter re i t y4 4r:.. -II- gigN �ttc �.._. �i1i� �i9I 370 D:I� . IlliiiiiiiiiRligliriNg 'I'm 11111111111111111111111111111111111111111111111111 'I IlliiilliciiiInfill'i �EEEIIISErIIrEEUIIII i . i dUihnimo.•..J U .... uit •TIE �• P ��, ���� . [!�:d�. , ;ter. ; ? ; �� �t ' 1111 Jam _ flu... g airsummiza iii ll c icii i VAIN IN UI nsinai s �11� � �1 ..� >�m71ErI�LvI Ii .... == i'I--.L,■.,!!!P��IO1i--I■__�••I. mI 7I■�■•aimini meIg- -H ■ .' ✓.' ._...«_..._ raF+," ...1` i 5 ✓ '�:/ F d.. .'r/✓{ 13 M ! a § ✓.. Y A:.. H v+f MEM Fill® Mir IIEE� Al L I'll !�I•��i.li#1tL� IM EEE �.a�zrry iiiiallitmri _Wit i! i ii I rivral=mmromn..11 lnainiEi��,_t ®i -®� I 1�20-XI6 LAND �'"��IIII1111 W V iIIII __ .4 _ :-rev ,r�-_ 111 �'4„ 10 :. �I1�r7I• f0 4 ,,, iii- `" ki ma .: 0.0 �� �m `— I ai " ��� �� �i'NI�{moi_- MIMIOUNWIMMIIMANZWYINIMIK=OMMilIMigli 1D ,�. ,D1 �,� III 71�t:..� Mom �� YF•�11�I,��e�� 1� �i.►� ��a►�®i --- &Lei 1�J ����i �� I��l.ir 141. ®L>��_.© _ ' _ l I®mummuiew.-•r-,Mwur�ilri.�.sL__ 4 I +��ri..rur.: . w[�l--_-.��i..���rTL. - c�._n�!�►z E�r 1111MMI Nei E) 20"X20" LANDLORD EXHAUST DUCT (E)94•X20• LANDLORD SUPPLY AIR DUCT -10 P/P/NG LEGEND IIMMINEMP - - -0- EXISTING PIPING NEW PIPING TENANT SPRINKLER PLAN K:::;;77 SCALE: 1/4" = 1'-0" t DESIGN CRITERIA DESIGN AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE LOCAL BUILDING CODE, N.F.P.A. 13 (1999 EDITION), AND ALL AUTHORITIES HAVING JURISDICTION. ORDINARY HAZARD (GROUP 2) AREAS: DENSITY: DESIGN AREA: MAX SPRINKLER COVERAGE: HOSE DEMAND: DURATION: 0.20 GPM/SQ.FT MOST DEMANDING 1500 SQ. FT. 130 SQ. FT./HEAD 250 GPM 60 MINUTES SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS" 1. "SALES" AREA SPRINKLER HEADS ARE TO BE FLAT OR MATTE BLACK SEMI -RECESSED HEADS WITH FLAT OR MATTE BLACK ESCUTCHEON. BASED ON RELIABLE AND ALTERNATE MAY BE VIKING OR GRINNELL AND MUST BE APPROVED BY THE HOWSTER CONSTRUCTION MANAGER PRIOR TO ORDERING AND ANY INSTALLATIONS. ALL EXPOSED PIPING SHALL BE PAINTED BROWN IN COLOR AND MUST BE COORDINATED WITH ALL TRADES. 2. "PORCH" AREA SPRINKLER HEADS ARE TO BE FLAT OR MATTE BLACK SEMI -RECESSED HEADS WITH FLAT OR MATE BLACK ESCUTCHEON. BASE BID TO BE RELIABLE MODEL OR EQUAL 3. 'NON -SALES" AREA SPRINKLER HEADS ARE TO BE WHITE CONCEALED HEADS WITH WHITE ESCUTCHEON. BASED ON RELIABLE AND ALTERNATE MAY BE VIKING OR GRINNELL. 4. "NON -SALES" OFFICE AND LAVATORY AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE. 5. 'MALL BULKHEAD' AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE. THE DESIGN INTENT IN THE RETAIL STORE AREAS IS TO INSTALL THE SPRINKLERS CENTERED BETWEEN THE BATTENS MOUNTED ON THE CEIUNG. PROVIDE SPRINKLER HEADS (UP RIGHT) ABOVE NE CEIUNG IN CONCEALED SPACES HAVING EXPOSED COMBUSTIBLE CONSTRUCTION. GENERAL NOTES SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 - 2007 ED . ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS ORDINARY HAZARD OCCUPANCY: 130 S.F. PER SPRINKLER MAX CALCULATED .20 / 1500 S.F - ORDINARY HAZARD GP 2. NEW PIPING TO BE 'DYNA-THREAD' THREADABLE THINWALL OVERSIZED SPRINKLER ESCUTCHEONS PROVIDED AT SPRINKLER CEILING PENETRATIONS PER IBC/ASCE 7 GENERAL NOTES ALL ABOVE GROUND FIRE PROTECTION SYSTEMS SHALL BE HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HOURS YAM NO VISIBLE LEAKAGE. ALL CONCEALED PIPING SHALL BE AIR TESTED, WITH NO LEAKAGE, PRIOR TO F1WNG SYSTEM WITH WATER. THE FIRE PROTECTION CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AUTHORITIES HAVING JURISDICTION 24 HOURS PRIOR TO THE TEST. THE ENGINEER SHALL WITNESS ALL TESTS. THE FIRE SPRINKLER SYSTEM SHALL BE SUPERVISED BY AN APPROVED CENTRAL STATION, PROPRIETARY STATION, OR REMOTE STATION MONITORING SYSTEM IN ACCORDANCE WITH N.F.P.A. 72, AND LOCAL AUTHORITY HAVING JURISDICTION. by others THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE WIRING OF ALL ELECTRICAL FIRE PROTECTION DEVICES AND EQUIPMENT WITH THE ELECTRICAL AND/OR FIRE ALARM CONTRACTOR. ALL FIRE ALARM WIRING BY ELECTRICAL CONTRACTOR. ALL DEVICES SHALL BE FURNISHED AND INSTALLED BY THE FIRE PROTECTION CONTRACTOR. THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE THE LAYOUT OF THE FIRE PROTECTION SYSTEM WITH ALL TRADES AND ARCHITECTURAL REFELECTED CEILING PLAN PRIOR TO INSTALLATION. THE FIRE PROTECTION CONTRACTOR SHALL CENTER (WITHIN 1") ALL PENDENT SPRINKLER HEADS INSTALLLED IN ACOUSTICAL LAY -IN CEIUNG TILES. ALL PENDANT SPRINKLER HEADS IN CEIUNGS SHALL BE SYMMETRICAL WITH UGHTING AND AIR DEVICES. SPRINKLER HEADS ARE REQUIRED ABOVE THE CEIUNG IN ALL AREAS OF CONCEALED SPACES. THE LOCATION OF EXTERIOR FIRE PROTECTION EQUIPMENT SUCH AS FIRE DEPARTMENT CONNECTIONS, TEST DRAINS, ETC., SHALL BE COORDINATED WITH THE ASSOCIATE ARCHITECT AND APPROVED BY THE LOCAL FIRE DEPARTMENT. FINAL APPROVAL IS SUBJECT TO ACCEPTANCE AND TESTING BY ALL AUTHORI11T1ES HAVING JURISDICTION. CONTRACTOR SHALL SEAL ALL PENETRATIONS OF FIRE RATED ASSEMBLIES (WALLS, FLOORS, ETC.) AS REQUIRED TO MAINTAIN SASSEMBLY RATING. REFER TO ARCHITECTURAL PLANS FOR FIRE RATINGS. MALL LOCATION PLAN ROM Macy; e. -rte- A s • vV• Hollister SPACE /1440 LEVEL 1 OF 3 Wi T IE ALIGN SPRINKLER HEADS IN UGHTNG GRID WHERE EVER POSSIBLE TYPICAL THROUGHOUT SPACE A 3-12-08 REVISE PER TUAZON ENGINEERING REVIEW OF 2-11-08 FILE COPY PROJECT TOTAL: 92 A COWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669. HOLLISTER Co. P AY Level 1 Store # 603 / Space #1440 Tukwila, WA 90025 DATE: 03/08 DRAWN: C.A. SCALE: NOTED 1 OF 1 U FIRE PROTECTION LEGEND D SYMBOL DESCRIPTION SPRINKLER SIN QTY 0 BLACK PENDANT TYPE HEAD W/ BLACK ESCUTCHEON RELIABLE Fl -FR Q.R. BLACK PENDENT 1/2' 155' W/ BLACK 1 -PC CANOPY R3615 2 O j . BLACK FULLY CONCEALED HEAD W/ BLACK ESCUTCHEON FOR THE SALES FLOOR RELIABLE G4A Q.R. CONCEALED PENDENT 1/2" 155' W/ BLACK COVER PLATE R5415 51 ® WHITE FULLY CONCEALED HEAD W/ WHITE ESCUTCHEONW/ RELIABLE G4A Q.R. CONCEALED PENDENT 1/2" 155' WHITE COVER PLATE R5415 39 ALIGN SPRINKLER HEADS IN UGHTNG GRID WHERE EVER POSSIBLE TYPICAL THROUGHOUT SPACE A 3-12-08 REVISE PER TUAZON ENGINEERING REVIEW OF 2-11-08 FILE COPY PROJECT TOTAL: 92 A COWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669. HOLLISTER Co. P AY Level 1 Store # 603 / Space #1440 Tukwila, WA 90025 DATE: 03/08 DRAWN: C.A. SCALE: NOTED 1 OF 1 U