Loading...
HomeMy WebLinkAboutPP - 717 SOUTHCENTER MALL - UNKNOWN TENANT - PERMITS AND PLANS717 SOUTHCENTER MALL ASSOCIATED PERMITS 14-S-110 CITY OF TUKWILA tit FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION -7/7 Site Address: 2000 Southcenter Mall King Co. Assessor's Tax No.: 9202470010 Suite Number: S1525 Floor: Tenant Name: Police Substation New Tenant? Q - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Travis Quaale Day Telephone: 206.349.5714 Company Name: Guardian Security Systems Mailing Aaaress:1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City State Zip E-mail Address: Fax Number: 206.628.499n Total number of new/relocated devices or sprinkler heads: 4 Valuation of Project (contractor's bid price): $ 2000 Scope of Work (please provide detailed information): Relocating 4 existing fire alarm devices. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than l 80 days each. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW OR AUTHORIZED GENT: Signature:/ \ Date: f , Lk " 1 Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** y� King Co. Assessor's Tax No.: Site Address: 7 / 7 �SCert�er^ Tenant Name: Po f %Ce. s(416 /(../on New Tenant? JA - Yes 111- No Property Owner's Name: \eso't \-t!j & man rneni- Mailing Address: Suite Number: Floor: City CONTACT PERSON -if there are questions about the submittal. Name: �` C 1 71:bi nsoi State Zip Day Telephone: 4 2 ' 4'8)" 7(DCD Company Name: Crc y\1) v Wofie-;-lon , VIC- Mailing Address: $c&X 1Z11Yv1 III Creek , mA el in P7... City State Zi E-mail Address: _ / 0 r1 zu - • I Fax Number: las./—m •(fzpx Total number of new/relocated devices or sprinkler heads: NO Valuation of Project (contractor's bid price): $ 1, 1.� Scope of Work (please provide detailed information): PM 7 ' ?elocra PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZEDnAGENT: Signature: �I- 2_ . Print Name: Ck-56 10, Poh//756r) Plan Permit App.doc Date: 6—'8*'/41 Day Telephone: 1125.14/.7W 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Tukwila Police Substation 717 Southcenter Mall Permit No.: 14-S-110 Date: May 14, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5” and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. LANDLORD WORK -POLICE SUBST SHEET NUM3ER SHEET TITLE FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON FA -01 SYSTEM INFORMATION FA -02 TYPICAL WRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX RELOCATION OF 2 EXISTING SPEAKER/STROBES, 2 EXISTING STROBES & 1 EXISTING CONTROL RELAY MODULE DUE TO THE POLICE SUBSTATION TENANT IMPROVEMENT BY THE LANDLORD SCOPE OF WORK WRE SCHEDULE A\ D C O\ D U IT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARN SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX (1) ER (2) ER (2) ER SYMBOL DESCRIPTION Without Comments CI As Noted in Red p Per The Attached Letter They plans have been reviewed by The Tukwila Fire I Prevention Bureau for conformance with current City standards. Acceptance Is subject to errors and I omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the E ;adequacy of design rests totally with the designer. ditians, deletions or = evisions to these drawings after this date wi vo • resubmittal of revised drawings for subsequent approval. -I Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 9 - l y_,By: MODEL 1 NOTICE completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement -of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing DEPARTMENT' Please call 206-575-4407 and give this Fire Permit No. and exact address for shut- down hutdown or restoration approval. MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY EX (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP HT -R ER INTERFACE MODULE WITH RELAY (EXISTING -RELOCATED) HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM DIER SPEAKER STROBE (EXISTING -RELOCATED) XER A.F.F. FIRE ALARM STROBE (EXISTING -RELOCATED) ABOVE FINISHED FLOOR SET -MC -CW SIEMENS ZR -MC -CW SIEMENS N/A 4S DEEP BOX CEILING W/ 1-1 /2" EXTN p. 4S DEEP BOX N/A N/A CEILING N/A ER EXISTING DEVICE RELOCATED N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM III 3 LEVELS ,�`; 171,275sf macys 4 LEVELS 25J.40,sf mczna • ESti=i EZ T/ Ctkm AWN 6,0 lI PVC �MM „,, DESO POLICE SUBSTATIO #2600 S tbt Y tan 4`3pi s I I ggxn , j4 p c.aEx ;ua mervyws 2 LEVELS 65,237sf PARIS'S Kip -s . LOCKER ROOM ftp Q-1 JJST S airs CHOICE CAS:.;. roue CC r LBRARY ll • I ERTEE 7 JCPLl_enney 3 LEVELS 276.46Ssf A110 RETAIL IRESTALIT SIp WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian ;7 AI D MAY a 6 2014 T1iKW�L.A Fi-RE c2 c '�av' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 1REV. BY: 0 DESCRIPTION SHOP DRAWINGS DATE 05/05/14 (i) co � z „0000 U) o W < E,crO LLI 7:1 w zz 0_ 1ScnT CCgog 0< W a LL CC 0 T CD T SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 05/05/ 14 BACKROUND PLAN PROVIDED BY: .OB NUMBER: 8793-1} SHEET Security Systems, Inc. All Rights Reserved FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-601.1Z DEDICATEDEMERGENCY NOTE: FOR AD01IONu. SPECSICATENS SEE PRIMUCT DOCUILENTADOIL *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC ITO TO NEXT ADDRESSAXE t+ DEVICE STOP TF LAST DEVICE s - FROM XLS COMM PANEL C' OR PREVIEW ADDRESSABLE DEVICE O 0 4 o HTRI—R 0 ®4 e. 0 0 O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) 3110 ORO N LL U 11 0 PAD -3 00 ° INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1- 1 2+2- 2 NC C NO + - + - + - + - + - (-) (+) 2 SPARE SPARE 2 SPARE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPLIFPLR RED (JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VOC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O F r L LI 4 0 0 HTRI—R 0 la 71 GROUND (C\ O 0 (+)) TO NEXT DEVICE OR (-) STOP IF LAST DEVICE ---> DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL • POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL U �J HORN/STROBE OR STROBE ONLY U U HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR t -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD / SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING ) TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX 1t Ii...v.1ti.tdie`.e'`Z2�u.�` .A. .+$* �J#.&ti A,L mac'' s�`1 1 .-�0 ... A�S.s.'A.. cc) JUNCTION BOX MOUNTED AGAINS I; CEILING SUPPORT o0` o 0 TO NEXT DEVICE CADDY BAR Dl SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I DMG I DESCRIPTION SHOP DRAWINGS Lu F- 0 105/05/14 z<<aaa z 0 C!) CO fO z O J 82z U QWO O7; wzz 0. 'dm cf) co cc c) OQLCICjo NF CC 0 0 z J J� J /GLE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 05/05/ 14 BACKROUND PLAN PROVIDED BY: _OB NUMBER: 8793-1} SHEET FA -02 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved , '' ,"t,,,,,i ';c4.,, ',,lf A,•,,'. ', ,- . LANDLORD SUBSTATION:. , , Load Calculations EXISTING SIEMENS PAD3 SignaI Extender Paiiel Battery Circuit Detail WORK , i- i CURRENT Wire Resistance 2.58 ------- ---- ---- ------; TOTAL= i 893.00 May 5, 2014 , - SHOP DRAWINGS Current, , .... , 0 , „.. , , , , Standby: ' , ' SET -MC -CW @15cd i 69! 0; , 2 1 ' SET -MC -CW @30cd 111 ' SET -MC -CW @75cd 200 222 200: Device Type Qty Amps Total Amps Total , . , . DEVICES , , - ZR -MC -CW @30a1 111 ,... ,, 7 j TOTAL mA= . 0 893! 14 i 328 ; 22.49! 893 Main System Board 1 0.03 0.03 0.030 0.030 1( WL * 2 )* (R/ft) i 1.69 (Total eOtLTiia 7.-77:—. 0.89 .._ .. ... .... .____ ,(E= I * R) 1.51 ...........,_ ___,.. 9 , : , 0.069 ' , EOL Voltage SET -MC -CW ©15CD SET -MC -CW ©30CD 12 . 24 :- E) . - - 22.49 0.111 5 0.2 S C 7 CD SET -MC -CW @95CD 7 ' 0.264 1.848 7R -MC -CW ©15CD 13 0.069 ZR -MC -CW ©30CD 6 0.111 0.666 0.03 Amps 2.544 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 2.544 Amps For 5 Minutes 0.214 Amp -hours 25% Derating= 1.167 Amp -hours Total System Current Load: 1.167 Amp -hours Battery r . J,., , o,,v j, ' , , 2vb , -.., i ,,,1',..,,,4,',5t . - $ . PROJECT: Panel: Date: Notification Appliance POLICE SUBSTATION - LANDLORD 'EXISTING PAD -3 BPS Circuit Detail WORK , i- i CURRENT Wire Resistance 2.58 ------- ---- ---- ------; TOTAL= i 893.00 May 5, 2014 , - SHOP DRAWINGS I C I 0 DATE SET -MC -CW @15cd i 69! 0; , 2 1 ' SET -MC -CW @30cd 111 ' SET -MC -CW @75cd 200 222 200: , r - .... 1 3 _....., , SET -MC -CW @95cd 2 ZR -MC -CW @15cd 69( 264 207! , . , . DEVICES , , - ZR -MC -CW @30a1 111 ,... ,, 7 j TOTAL mA= . 0 893! 14 i 328 ; 22.49! 893 Total Wire Resistance ( R ) , 1( WL * 2 )* (R/ft) i 1.69 (Total eOtLTiia 7.-77:—. 0.89 .._ .. ... .... .____ ,(E= I * R) 1.51 ...........,_ ___,.. Total Device Load, Amps (1) • .Voltage Drop ( E) : , : , , ' , EOL Voltage . 24 :- E) . - - 22.49 SYSTEM CALCULATIONS FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 05/05/14 2 <<<<< EXISTING FA JUNCTION BOX ER S1-1 30cd V-1 ER ER s,v,v s,v,v S1-2 15cd ER ER EX s,v,v s,v,v s,v,v EX S,V,V EX S1-4 30cd V-2 S1-3 15cd S1-5 15cd S1-6 75cd V-3 S1-7 95cd V-4 EOL S1 FLAG NOTES: EXISTING DEVICE THAT WERE RELOCATED. z 0 ca z :a° o c7, w E < , z <0cf0 o w 0 w z CD Ci) 1.< CC < 0 w0 c\I 0 LT Cr 0 0 z cc 0 0 w z w z 0 Ci) z (/) z0 w (/) >C/)- 7S--CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:05/05/14 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM OB NUMBER: 8793-1} 1' SHEET Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FA -03 TO EXIS�TIN.G /DEVICE j - IST G JUCT1e / FLAG NOTES: EXISTING DEVICE THAT WERE RELOCATED. OFFICE 102 ER HT -R NEW 150 AMB ,$ ELEC,TRICAC PAN, Isi , EL/ , ' / S$S1 j 4#*(15.1- *A1V r s,v,vI E TH RO N, v, 1S3 3 S1-3 1 5cd ARR FIRE ALARM SYSTEM PLAN 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 1!) O U) 0 z O (/) Wci)D z cco HI W F-51— z wz � w= co 0X161 (/) CC og- o < cc Pc-1 �w Cr 0 J 0 z W �CALE: 1/2"=1'0" 0. DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 05/05/14 BACKROUND PLAN PROVIDED BY: .JOB NUMBER: 8793-1i SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FlexHead Sprinkler Drop 1%5;�; Corrugated stainless steel hose with stainless steel brai ��'�;5;:;;�• . f available In 2', 3',4',5' & 6' legnths . • • Mute -Port Bracket • Adjustable Hub FLEVIEth I NO U5101E5 • Flexhead''tomniercial Ceiling Unit T -Bar Ceiling Installation " • Model #2024,2036,2048,060,2072 REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 7 — Add Reliable Mdel G5-56 QR 165° White Concealed Pendents 1/2 x 1/2 o 3 — Relocate Reliable Model G5-56 QR 165° White Concealed Pendents 1/2 x 1/2 CCE TE O Without Comments o As Noted in Red la Per The Attached Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformancewith current City standards. Acceptance.. Is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: s- l LI ' l Ll By: sli TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. I`I-S-110 and exact address for shut- down -or restoration approval. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C—CLAMP WITH SE7' SCREW 3/8' ALL THREAD Rao PIPE SWIVEL RING STEEL, JQIST/muss HANGER DETAIL NTS • �-^) 0 0 0 0 WASHINGTON SATE j CERTIFICATE OF CO ETENCY FIRE PROTECTION SPRINI< LER SYSTEMS g ■ • a ■ . ■ ■ ■ ▪ . John J. Abel 9760 -0591 -CG Cro Fire Pro C Level 3. Ion, I ■ Signature ■s POLICE SUBSTATION . NOT TO SCALE CROWN FIRE PROTECTION: INCORPORATED_ P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113.. PH. (425) 481-7669 Police Substation Landlord Work -7/7 S outhcenter Mall Tukwila, WA 98188 DATE: 5.7. ly DRAWN: SCALE: ‘' Expires 12131114 PAID MAY :22014 .rUKWI...A FIRE_ z�ioS41ezav 717 SOUTHCENTER MALL ASSOCIATED PERMITS 14-S-110 CITY OF TUKWILA tit FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION -7/7 Site Address: 2000 Southcenter Mall King Co. Assessor's Tax No.: 9202470010 Suite Number: S1525 Floor: Tenant Name: Police Substation New Tenant? Q - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Travis Quaale Day Telephone: 206.349.5714 Company Name: Guardian Security Systems Mailing Aaaress:1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City State Zip E-mail Address: Fax Number: 206.628.499n Total number of new/relocated devices or sprinkler heads: 4 Valuation of Project (contractor's bid price): $ 2000 Scope of Work (please provide detailed information): Relocating 4 existing fire alarm devices. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than l 80 days each. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW OR AUTHORIZED GENT: Signature:/ \ Date: f , Lk " 1 Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** y� King Co. Assessor's Tax No.: Site Address: 7 / 7 �SCert�er^ Tenant Name: Po f %Ce. s(416 /(../on New Tenant? JA - Yes 111- No Property Owner's Name: \eso't \-t!j & man rneni- Mailing Address: Suite Number: Floor: City CONTACT PERSON -if there are questions about the submittal. Name: �` C 1 71:bi nsoi State Zip Day Telephone: 4 2 ' 4'8)" 7(DCD Company Name: Crc y\1) v Wofie-;-lon , VIC- Mailing Address: $c&X 1Z11Yv1 III Creek , mA el in P7... City State Zi E-mail Address: _ / 0 r1 zu - • I Fax Number: las./—m •(fzpx Total number of new/relocated devices or sprinkler heads: NO Valuation of Project (contractor's bid price): $ 1, 1.� Scope of Work (please provide detailed information): PM 7 ' ?elocra PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZEDnAGENT: Signature: �I- 2_ . Print Name: Ck-56 10, Poh//756r) Plan Permit App.doc Date: 6—'8*'/41 Day Telephone: 1125.14/.7W 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Tukwila Police Substation 717 Southcenter Mall Permit No.: 14-S-110 Date: May 14, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5” and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. LANDLORD WORK -POLICE SUBST SHEET NUM3ER SHEET TITLE FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON FA -01 SYSTEM INFORMATION FA -02 TYPICAL WRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX RELOCATION OF 2 EXISTING SPEAKER/STROBES, 2 EXISTING STROBES & 1 EXISTING CONTROL RELAY MODULE DUE TO THE POLICE SUBSTATION TENANT IMPROVEMENT BY THE LANDLORD SCOPE OF WORK WRE SCHEDULE A\ D C O\ D U IT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARN SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX (1) ER (2) ER (2) ER SYMBOL DESCRIPTION Without Comments CI As Noted in Red p Per The Attached Letter They plans have been reviewed by The Tukwila Fire I Prevention Bureau for conformance with current City standards. Acceptance Is subject to errors and I omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the E ;adequacy of design rests totally with the designer. ditians, deletions or = evisions to these drawings after this date wi vo • resubmittal of revised drawings for subsequent approval. -I Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 9 - l y_,By: MODEL 1 NOTICE completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement -of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing DEPARTMENT' Please call 206-575-4407 and give this Fire Permit No. and exact address for shut- down hutdown or restoration approval. MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY EX (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP HT -R ER INTERFACE MODULE WITH RELAY (EXISTING -RELOCATED) HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM DIER SPEAKER STROBE (EXISTING -RELOCATED) XER A.F.F. FIRE ALARM STROBE (EXISTING -RELOCATED) ABOVE FINISHED FLOOR SET -MC -CW SIEMENS ZR -MC -CW SIEMENS N/A 4S DEEP BOX CEILING W/ 1-1 /2" EXTN p. 4S DEEP BOX N/A N/A CEILING N/A ER EXISTING DEVICE RELOCATED N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM III 3 LEVELS ,�`; 171,275sf macys 4 LEVELS 25J.40,sf mczna • ESti=i EZ T/ Ctkm AWN 6,0 lI PVC �MM „,, DESO POLICE SUBSTATIO #2600 S tbt Y tan 4`3pi s I I ggxn , j4 p c.aEx ;ua mervyws 2 LEVELS 65,237sf PARIS'S Kip -s . LOCKER ROOM ftp Q-1 JJST S airs CHOICE CAS:.;. roue CC r LBRARY ll • I ERTEE 7 JCPLl_enney 3 LEVELS 276.46Ssf A110 RETAIL IRESTALIT SIp WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian ;7 AI D MAY a 6 2014 T1iKW�L.A Fi-RE c2 c '�av' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 1REV. BY: 0 DESCRIPTION SHOP DRAWINGS DATE 05/05/14 (i) co � z „0000 U) o W < E,crO LLI 7:1 w zz 0_ 1ScnT CCgog 0< W a LL CC 0 T CD T SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 05/05/ 14 BACKROUND PLAN PROVIDED BY: .OB NUMBER: 8793-1} SHEET Security Systems, Inc. All Rights Reserved FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-601.1Z DEDICATEDEMERGENCY NOTE: FOR AD01IONu. SPECSICATENS SEE PRIMUCT DOCUILENTADOIL *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC ITO TO NEXT ADDRESSAXE t+ DEVICE STOP TF LAST DEVICE s - FROM XLS COMM PANEL C' OR PREVIEW ADDRESSABLE DEVICE O 0 4 o HTRI—R 0 ®4 e. 0 0 O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) 3110 ORO N LL U 11 0 PAD -3 00 ° INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1- 1 2+2- 2 NC C NO + - + - + - + - + - (-) (+) 2 SPARE SPARE 2 SPARE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPLIFPLR RED (JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VOC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O F r L LI 4 0 0 HTRI—R 0 la 71 GROUND (C\ O 0 (+)) TO NEXT DEVICE OR (-) STOP IF LAST DEVICE ---> DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL • POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL U �J HORN/STROBE OR STROBE ONLY U U HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR t -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD / SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING ) TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX 1t Ii...v.1ti.tdie`.e'`Z2�u.�` .A. .+$* �J#.&ti A,L mac'' s�`1 1 .-�0 ... A�S.s.'A.. cc) JUNCTION BOX MOUNTED AGAINS I; CEILING SUPPORT o0` o 0 TO NEXT DEVICE CADDY BAR Dl SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I DMG I DESCRIPTION SHOP DRAWINGS Lu F- 0 105/05/14 z<<aaa z 0 C!) CO fO z O J 82z U QWO O7; wzz 0. 'dm cf) co cc c) OQLCICjo NF CC 0 0 z J J� J /GLE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 05/05/ 14 BACKROUND PLAN PROVIDED BY: _OB NUMBER: 8793-1} SHEET FA -02 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved , '' ,"t,,,,,i ';c4.,, ',,lf A,•,,'. ', ,- . LANDLORD SUBSTATION:. , , Load Calculations EXISTING SIEMENS PAD3 SignaI Extender Paiiel Battery Circuit Detail WORK , i- i CURRENT Wire Resistance 2.58 ------- ---- ---- ------; TOTAL= i 893.00 May 5, 2014 , - SHOP DRAWINGS Current, , .... , 0 , „.. , , , , Standby: ' , ' SET -MC -CW @15cd i 69! 0; , 2 1 ' SET -MC -CW @30cd 111 ' SET -MC -CW @75cd 200 222 200: Device Type Qty Amps Total Amps Total , . , . DEVICES , , - ZR -MC -CW @30a1 111 ,... ,, 7 j TOTAL mA= . 0 893! 14 i 328 ; 22.49! 893 Main System Board 1 0.03 0.03 0.030 0.030 1( WL * 2 )* (R/ft) i 1.69 (Total eOtLTiia 7.-77:—. 0.89 .._ .. ... .... .____ ,(E= I * R) 1.51 ...........,_ ___,.. 9 , : , 0.069 ' , EOL Voltage SET -MC -CW ©15CD SET -MC -CW ©30CD 12 . 24 :- E) . - - 22.49 0.111 5 0.2 S C 7 CD SET -MC -CW @95CD 7 ' 0.264 1.848 7R -MC -CW ©15CD 13 0.069 ZR -MC -CW ©30CD 6 0.111 0.666 0.03 Amps 2.544 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 2.544 Amps For 5 Minutes 0.214 Amp -hours 25% Derating= 1.167 Amp -hours Total System Current Load: 1.167 Amp -hours Battery r . J,., , o,,v j, ' , , 2vb , -.., i ,,,1',..,,,4,',5t . - $ . PROJECT: Panel: Date: Notification Appliance POLICE SUBSTATION - LANDLORD 'EXISTING PAD -3 BPS Circuit Detail WORK , i- i CURRENT Wire Resistance 2.58 ------- ---- ---- ------; TOTAL= i 893.00 May 5, 2014 , - SHOP DRAWINGS I C I 0 DATE SET -MC -CW @15cd i 69! 0; , 2 1 ' SET -MC -CW @30cd 111 ' SET -MC -CW @75cd 200 222 200: , r - .... 1 3 _....., , SET -MC -CW @95cd 2 ZR -MC -CW @15cd 69( 264 207! , . , . DEVICES , , - ZR -MC -CW @30a1 111 ,... ,, 7 j TOTAL mA= . 0 893! 14 i 328 ; 22.49! 893 Total Wire Resistance ( R ) , 1( WL * 2 )* (R/ft) i 1.69 (Total eOtLTiia 7.-77:—. 0.89 .._ .. ... .... .____ ,(E= I * R) 1.51 ...........,_ ___,.. Total Device Load, Amps (1) • .Voltage Drop ( E) : , : , , ' , EOL Voltage . 24 :- E) . - - 22.49 SYSTEM CALCULATIONS FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 05/05/14 2 <<<<< EXISTING FA JUNCTION BOX ER S1-1 30cd V-1 ER ER s,v,v s,v,v S1-2 15cd ER ER EX s,v,v s,v,v s,v,v EX S,V,V EX S1-4 30cd V-2 S1-3 15cd S1-5 15cd S1-6 75cd V-3 S1-7 95cd V-4 EOL S1 FLAG NOTES: EXISTING DEVICE THAT WERE RELOCATED. z 0 ca z :a° o c7, w E < , z <0cf0 o w 0 w z CD Ci) 1.< CC < 0 w0 c\I 0 LT Cr 0 0 z cc 0 0 w z w z 0 Ci) z (/) z0 w (/) >C/)- 7S--CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:05/05/14 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM OB NUMBER: 8793-1} 1' SHEET Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FA -03 TO EXIS�TIN.G /DEVICE j - IST G JUCT1e / FLAG NOTES: EXISTING DEVICE THAT WERE RELOCATED. OFFICE 102 ER HT -R NEW 150 AMB ,$ ELEC,TRICAC PAN, Isi , EL/ , ' / S$S1 j 4#*(15.1- *A1V r s,v,vI E TH RO N, v, 1S3 3 S1-3 1 5cd ARR FIRE ALARM SYSTEM PLAN 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 1!) O U) 0 z O (/) Wci)D z cco HI W F-51— z wz � w= co 0X161 (/) CC og- o < cc Pc-1 �w Cr 0 J 0 z W �CALE: 1/2"=1'0" 0. DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 05/05/14 BACKROUND PLAN PROVIDED BY: .JOB NUMBER: 8793-1i SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FlexHead Sprinkler Drop 1%5;�; Corrugated stainless steel hose with stainless steel brai ��'�;5;:;;�• . f available In 2', 3',4',5' & 6' legnths . • • Mute -Port Bracket • Adjustable Hub FLEVIEth I NO U5101E5 • Flexhead''tomniercial Ceiling Unit T -Bar Ceiling Installation " • Model #2024,2036,2048,060,2072 REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 7 — Add Reliable Mdel G5-56 QR 165° White Concealed Pendents 1/2 x 1/2 o 3 — Relocate Reliable Model G5-56 QR 165° White Concealed Pendents 1/2 x 1/2 CCE TE O Without Comments o As Noted in Red la Per The Attached Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformancewith current City standards. Acceptance.. Is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: s- l LI ' l Ll By: sli TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. I`I-S-110 and exact address for shut- down -or restoration approval. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C—CLAMP WITH SE7' SCREW 3/8' ALL THREAD Rao PIPE SWIVEL RING STEEL, JQIST/muss HANGER DETAIL NTS • �-^) 0 0 0 0 WASHINGTON SATE j CERTIFICATE OF CO ETENCY FIRE PROTECTION SPRINI< LER SYSTEMS g ■ • a ■ . ■ ■ ■ ▪ . John J. Abel 9760 -0591 -CG Cro Fire Pro C Level 3. Ion, I ■ Signature ■s POLICE SUBSTATION . NOT TO SCALE CROWN FIRE PROTECTION: INCORPORATED_ P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113.. PH. (425) 481-7669 Police Substation Landlord Work -7/7 S outhcenter Mall Tukwila, WA 98188 DATE: 5.7. ly DRAWN: SCALE: ‘' Expires 12131114 PAID MAY :22014 .rUKWI...A FIRE_ z�ioS41ezav