PP - 718 SOUTHCENTER MALL - TMOBILE - PERMITS AND PLANS
718 SOUTHCENTER MALL ASSOCIATED PERMITS 17-F-218 08-F-475 08-S-479 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION 2 ��j,j 8 King Co. Assessor's Tax No.:491 l- -cola �• enc ,n I 101(-- O Imo} Ct818u i -, i8 Floor: ts+ Site Addres . • + h wte Number: Tenant Name: Property Owner's Namel1\10-1-r-o, Il7175-Feili Tct �- Mailing Address: New Tenant? 1:1- Yesl- No CONTACTPERSON-if there are questions abo ut the submittal. Name: CiJftr'f1'J\ &&0' r4' - Company Name: Cl Mailing Address:13'113 134 Ave City Day Telephone: State Zip ZZ9 \AA 98 &I City State Zip E-mail Address:ael ttm ran, Fax Number: Contractor's City of Tukwila ,G� �i� NICET III number: Business License numberDLIS- Y a28 '' Total number of new/relocated devices or sprinkler heads: 113 Valuation of Project (contractor's bid price): $ j ( r UVU Scope of Work (please provide detailed information): 5k Gfi on (`''l rf f aii cki at, (4) deui'c-Q PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. This figure will be Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HA UNDER PENALTY OF P r ' R : Y. FOR THIS PERMBUILDIN r Vii*AS Signature: Print Nam AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY D AGENT: Plan Permit App.doc Date: %1 ie (H" Day Telephone: 06 •(�L/S .22'1 8/22/14 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: T -Mobile 718 Southcenter Mall Permit No.: 08-S-479 Date: October 9, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/ inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more sprinkler heads require hydrostatic test and system isolation if necessary. • These conditions apply to any sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2007 Edition. COSCO FIRE PROTECTION, INC. 15000 WOODINVILLE REDMOND ROAD NE #B800 WOODINVILLE,WA 98072-4502 HYDRAULIC CALCULATIONS FOR T -Mobile 718 Southcenter Mall, Suite #1475 Tukwila, Wa. 98188-2823 FILE NUMBER: 25SS - 7981 DATE: OCT 9, 2008 -DESIGN DATA - OCCUPANCY CLASSIFICATION: Ordinary Group II DENSITY: 0.20 gpm / 1500 sq. ft. AREA OF APPLICATION: 1,669 sq. ft. COVERAGE PER SPRINKLER: 130 sq. ft. Max. NUMBER OF SPRINKLERS CALCULATED: 23 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 689.5 gpm TOTAL WATER REQUIRED (including hose): 939.5 gpm FLOW AND PRESSURE (@ BOR): 689.5 gpm @ 79.4 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: Cosco Fire Protection, Inc. DESIGN/LAYOUT BY: Justin Johnson AUTHORITY HAVING JURISDICTION: City of Tukwila CONTRACTOR CERTIFICATION NUMBER: COSCOFP110NM CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 4903012830) HRS SYSTEMS, INC. TUCKER, GA 30084 TUCKER, GA 30084 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/9/2008S 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble WATER SUPPLY DATA SOURCE NODE TAG SOURCE STATIC PRESS. (PSI) 140.0 RESID. FLOW PRESS. @ (PSI) (GPM) 20.0 10900.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE (FT) S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 S15 S16 S17 S18 S19 S20 S21 S22 S23 L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 10.5 10.5 9.0 9.0 9.0 10.5 10.5 10.5 10.5 10.5 9.0 9.0 9.0 10.5 10.5 10.5 9.0 9.0 10.5 10.5 10.5 10.5 10.5 14.5 14.5 15.0 15.0 14.5 14.5 14.5 14.5 14.5 15.0 15.0 AVAIL. PRESS. (PSI) 138.7 TOTAL @ DEMAND (GPM) 939.5 GPM 250.0 GPM 0.0 GPM 689.5 GPM PRESSURE (PSI) K= 5.60 37.0 K= 5.60 36.6 K= 5.60 23.3 K= 5.60 21.6 K= 5.60 23.0 K= 5.60 24.9 K= 5.60 26.3 K= 5.60 30.3 K= 5.60 37.2 K= 5.60 36.7 K= 5.60 21.6 K= 5.60 23.4 K= 5.60 22.7 K= 5.60 25.0 K= 5.60 26.3 K= 5.60 30.4 K= 5.60 27.7 K= 5.60 27.3 K= 5.60 28.1 K= 5.60 29.1 K= 5.60 32.2 K= 5.60 37.4 K= 5.60 36.9 48.0 48.4 29.3 30.3 32.6 34.7 40.2 48.2 48.6 29.5 30.5 REQ'D PRESS. (PSI) 939.5 87.0 DISCHARGE (GPM) 34.1 33.9 27.0 26.0 26.8 28.0 28.7 30.8 34.1 33.9 26.0 27.1 26.7 28.0 28.7 30.9 29.4 29.3 29.7 30.2 31.8 34.3 34.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 10/9/20085 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) L12 14.5 32.9 L13 14.5 34.8 L14 14.5 40.3 L15 15.0 35.2 L16 15.0 35.5 L17 14.5 36.9 L18 14.5 38.4 L19 14.5 42.6 L20 14.5 48.5 L21 14.5 48.9 M1 14.5 50.5 M2 14.5 50.5 M3 14.5 50.6 M4 14.5 50.7 M5 14.5 51.1 M6 14.5 51.1 TOR 14.5 72.7 BOR 2.0 79.4 M7 2.0 79.5 BFO 4.0 78.8 BFI 4.0 83.3 UG1 1.2 - - - - 84.5 - - - SOURCE -4.0 SOURCE 87.0 689.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/9/20085 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -34.1 1.049 PL 28.38 PF 12.7 S1 10.5 5.6 37.0 34.1 12.7 120 FTG 4E PE -1.7 L1 14.5 0.0 48.0 0.0 0.349 TL 36.38 PV Pipe: 2 -33.9 1.049 PL 28.38 PF 13.6 S2 10.5 5.6 36.6 33.9 12.6 120 FTG 3ET PE -1.7 L2 14.5 0.0 48.4 0.0 0.345 TL 39.38 PV Pipe: 3 -27.0 1.049 PL 30.04 PF 8.6 S3 9.0 5.6 23.3 27.0 10.0 120 FTG 4E PE -2.6 L3 15.0 0.0 29.3 0.0 0.227 TL 38.04 PV Pipe: 4 -26.0 1.049 PL 33.62 PF 10.3 S4 9.0 5.6 21.6 26.0 9.7 120 FTG 5ET PE -2.6 L3 15.0 0.0 29.3 0.0 0.212 TL 48.62 PV Pipe: 5 -26.8 1.049 PL 33.04 PF 9.9 S5 9.0 5.6 23.0 26.8 10.0 120 FTG 3ET PE -2.6 L4 15.0 0.0 30.3 0.0 0.224 TL 44.04 PV Pipe: 6 -28.0 1.049 PL 27.92 PF 9.4 S6 10.5 5.6 24.9 28.0 10.4 120 FTG 3ET PE -1.7 L5 14.5 0.0 32.6 0.0 0.242 TL 38.92 PV Pipe: 7 -28.7 1.049 PL 28.79 PF 10.1 S7 10.5 5.6 26.3 28.7 10.7 120 FTG 3ET PE -1.7 L6 14.5 0.0 34.7 0.0 0.254 TL 39.79 PV Pipe: 8 -30.8 1.049 PL 28.83 PF 11.6 S8 10.5 5.6 30.3 30.8 11.5 120 FTG 3ET PE -1.7 L7 14.5 0.0 40.2 0.0 0.290 TL 39.83 PV Pipe: 9 -34.1 1.049 PL 28.38 PF 12.7 S9 10.5 5.6 37.2 34.1 12.7 120 FTG 4E PE -1.7 L8 14.5 0.0 48.2 0.0 0.350 TL 36.38 PV Pipe: 10 -33.9 1.049 PL 28.38 PF 13.6 S10 10.5 5.6 36.7 33.9 12.6 120 FTG 3ET PE -1.7 L9 14.5 0.0 48.6 0.0 0.346 TL 39.38 PV Pipe: 11 -26.0 1.049 PL 34.75 PF 10.5 S11 9.0 5.6 21.6 26.0 9.7 120 FTG 5ET PE -2.6 L10 15.0 0.0 29.5 0.0 0.211 TL 49.75 PV Pipe: 12 -27.1 1.049 PL 29.83 PF 8.6 S12 9.0 5.6 23.4 27.1 10.1 120 FTG 4E PE -2.6 L10 15.0 0.0 29.5 0.0 0.228 TL 37.83 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 10/9/2008S 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -26.7 1.049 PL 35.83 PF 10.4 S13 9.0 5.6 22.7 26.7 9.9 120 FTG 3ET PE -2.6 L11 15.0 0.0 30.5 0.0 0.222 TL 46.83 PV Pipe: 14 -28.0 1.049 PL 28.46 PF 9.6 S14 10.5 5.6 25.0 28.0 10.4 120 FTG 3ET PE -1.7 L12 14.5 0.0 32.9 0.0 0.243 TL 39.46 PV Pipe: 15 -28.7 1.049 PL 29.08 PF 10.2 S15 10.5 5.6 26.3 28.7 10.7 120 FTG 3ET PE -1.7 L13 14.5 0.0 34.8 0.0 0.255 TL 40.08 PV Pipe: 16 -30.9 1.049 PL 29.12 PF 11.7 S16 10.5 5.6 30.4 30.9 11.5 120 FTG 3ET PE -1.7 L14 14.5 0.0 40.3 0.0 0.290 TL 40.12 PV Pipe: 17 -29.4 1.049 PL 30.04 PF 10.1 S17 9.0 5.6 27.7 29.4 10.9 120 FTG 4E PE -2.6 L15 15.0 0.0 35.2 0.0 0.266 TL 38.04 PV Pipe: 18 -29.3 1.049 PL 30.04 PF 10.8 S18 9.0 5.6 27.3 29.3 10.9 120 FTG 3ET PE -2.6 L16 15.0 0.0 35.5 0.0 0.263 TL 41.04 PV Pipe: 19 -29.7 1.049 PL 28.04 PF 10.6 S19 10.5 5.6 28.1 29.7 11.0 120 FTG 3ET PE -1.7 L17 14.5 0.0 36.9 0.0 0.270 TL 39.04 PV Pipe: 20 -30.2 1.049 PL 28.42 PF 11.0 S20 10.5 5.6 29.1 30.2 11.2 120 FTG 3ET PE -1.7 L18 14.5 0.0 38.4 0.0 0.279 TL 39.42 PV Pipe: 21 -31.8 1.049 PL 28.38 PF 12.1 S21 10.5 5.6 32.2 31.8 11.8 120 FTG 3ET PE -1.7 L19 14.5 0.0 42.6 0.0 0.307 TL 39.38 PV Pipe: 22 -34.3 1.049 PL 28.38 PF 12.8 S22 10.5 5.6 37.4 34.3 12.7 120 FTG 4E PE -1.7 L20 14.5 0.0 48.5 0.0 0.352 TL 36.38 PV Pipe: 23 -34.0 1.049 PL 28.38 PF 13.7 S23 10.5 5.6 36.9 34.0 12.6 120 FTG 3ET PE -1.7 L21 14.5 0.0 48.9 0.0 0.348 TL 39.38 PV Pipe: 24 -34.1 1.610 PL 9.79 PF 0.4 L1 14.5 0.0 48.0 0.0 5.4 120 FTG ---- PE 0.0 L2 14.5 0.0 48.4 0.0 0.043 TL 9.79 PV Pipe: 25 -68.0 1.610 PL 5.46 PF 2.1 L2 14.5 0.0 48.4 0.0 10.7 120 FTG T PE 0.0 M1 14.5 0.0 50.5 0.0 0.155 TL 13.46 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 10/9/20085 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 26 -53.0 1.610 PL 9.94 PF 1.0 L3 15.0 0.0 29.3 0.0 8.4 120 FTG ---- PE 0.0 L4 15.0 0.0 30.3 0.0 0.098 TL 9.94 PV Pipe: 27 -79.9 1.610 PL 10.29 PF 2.2 L4 15.0 0.0 30.3 0.0 12.6 120 FTG ---- PE 0.2 L5 14.5 0.0 32.6 0.0 0.209 TL 10.29 PV Pipe: 28 -107.8 1.610 PL 5.58 PF 2.0 L5 14.5 0.0 32.6 0.0 17.0 120 FTG ---- PE 0.0 L6 14.5 0.0 34.7 0.0 0.365 TL 5.58 PV Pipe: 29 -136.6 1.610 PL 9.73 PF 5.5 L6 14.5 0.0 34.7 0.0 21.5 120 FTG ---- PE 0.0 L7 14.5 0.0 40.2 0.0 0.565 TL 9.73 PV Pipe: 30 -167.4 1.610 PL 4.58 PF 10.4 L7 14.5 0.0 40.2 0.0 26.4 120 FTG T PE 0.0 M2 14.5 0.0 50.5 0.0 0.823 TL 12.58 PV Pipe: 31 -34.1 1.610 PL 10.02 PF 0.4 L8 14.5 0.0 48.2 0.0 5.4 120 FTG ---- PE 0.0 L9 14.5 0.0 48.6 0.0 0.043 TL 10.02 PV Pipe: 32 -68.1 1.610 PL 5.23 PF 2.1 L9 14.5 0.0 48.6 0.0 10.7 120 FTG T PE 0.0 M3 14.5 0.0 50.6 0.0 0.156 TL 13.23 PV Pipe: 33 -53.1 1.610 PL 9.94 PF 1.0 L10 15.0 0.0 29.5 0.0 8.4 120 FTG ---- PE 0.0 L11 15.0 0.0 30.5 0.0 0.098 TL 9.94 PV Pipe: 34 -79.8 1.610 PL 10.52 PF 2.2 L11 15.0 0.0 30.5 0.0 12.6 120 FTG ---- PE 0.2 L12 14.5 0.0 32.9 0.0 0.209 TL 10.52 PV Pipe: 35 -107.8 1.610 PL 5.35 PF 1.9 L12 14.5 0.0 32.9 0.0 17.0 120 FTG ---- PE 0.0 L13 14.5 0.0 34.8 0.0 0.364 TL 5.35 PV Pipe: 36 -136.5 1.610 PL 9.73 PF 5.5 L13 14.5 0.0 34.8 0.0 21.5 120 FTG ---- PE 0.0 L14 14.5 0.0 40.3 0.0 0.564 TL 9.73 PV Pipe: 37 -167.4 1.610 PL 4.58 PF 10.4 L14 14.5 0.0 40.3 0.0 26.4 120 FTG T PE 0.0 M4 14.5 0.0 50.7 0.0 0.823 TL 12.58 PV Pipe: 38 -29.4 1.610 PL 9.94 PF 0.3 L15 15.0 0.0 35.2 0.0 4.6 120 FTG ---- PE 0.0 L16 15.0 0.0 35.5 0.0 0.033 TL 9.94 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 10/9/2008S 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 39 -58.7 1.610 PL 10.29 PF 1.2 L16 15.0 0.0 35.5 0.0 9.3 120 FTG ---- PE 0.2 L17 14.5 0.0 36.9 0.0 0.118 TL 10.29 PV Pipe: 40 -88.4 1.610 PL 5.58 PF 1.4 L17 14.5 0.0 36.9 0.0 13.9 120 FTG ---- PE 0.0 L18 14.5 0.0 38.4 0.0 0.253 TL 5.58 PV Pipe: 41 -118.6 1.610 PL 9.73 PF 4.2 L18 14.5 0.0 38.4 0.0 18.7 120 FTG ---- PE 0.0 L19 14.5 0.0 42.6 0.0 0.435 TL 9.73 PV Pipe: 42 -150.4 1.610 PL 4.58 PF 8.5 L19 14.5 0.0 42.6 0.0 23.7 120 FTG T PE 0.0 M5 14.5 0.0 51.1 0.0 0.675 TL 12.58 PV Pipe: 43 -34.3 1.610 PL 9.04 PF 0.4 L20 14.5 0.0 48.5 0.0 5.4 120 FTG ---- PE 0.0 L21 14.5 0.0 48.9 0.0 0.044 TL 9.04 PV Pipe: 44 -68.3 1.610 PL 6.21 PF 2.2 L21 14.5 0.0 48.9 0.0 10.8 120 FTG T PE 0.0 M6 14.5 0.0 51.1 0.0 0.157 TL 14.21 PV Pipe: 45 -68.0 4.260 PL 0.54 PF 0.0 M1 14.5 0.0 50.5 0.0 1.5 120 FTG ---- PE 0.0 M2 14.5 0.0 50.5 0.0 0.001 TL 0.54 PV Pipe: 46 -235.4 4.260 PL 9.96 PF 0.1 M2 14.5 0.0 50.5 0.0 5.3 120 FTG ---- PE 0.0 M3 14.5 0.0 50.6 0.0 0.014 TL 9.96 PV Pipe: 47 -303.4 4.260 PL 0.52 PF 0.0 M3 14.5 0.0 50.6 0.0 6.8 120 FTG ---- PE 0.0 M4 14.5 0.0 50.7 0.0 0.022 TL 0.52 PV Pipe: 48 -470.8 4.260 PL 8.71 PF 0.4 M4 14.5 0.0 50.7 0.0 10.6 120 FTG ---- PE 0.0 M5 14.5 0.0 51.1 0.0 0.049 TL 8.71 PV Pipe: 49 -621.2 4.260 PL 0.40 PF 0.0 M5 14.5 0.0 51.1 0.0 14.0 120 FTG ---- PE 0.0 M6 14.5 0.0 51.1 0.0 0.081 TL 0.40 PV Pipe: 50 -689.5 4.260 PL 152.25 PF 21.5 M6 14.5 0.0 51.1 0.0 15.5 120 FTG 3ET PE 0.0 TOR 14.5 0.0 72.7 0.0 0.099 TL 218.15 PV Pipe: 51 -689.5 6.357 PL 12.50 PF 1.3 TOR 14.5 0.0 72.7 0.0 7.0 120 FTG TC PE 5.4 BOR 2.0 0.0 79.4 0.0 0.014 TL 90.40 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 10/9/2008S 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 52 -689.5 8.249 PL 5.67 PF 0.1 BOR 2.0 0.0 79.4 0.0 4.1 120 FTG E PE 0.0 M7 2.0 0.0 79.5 0.0 0.004 TL 25.67 PV Pipe: 53 -689.5 10.275 PL 33.50 PF 0.2 M7 2.0 0.0 79.5 0.0 2.7 140 FTG 4EB PE -0.9 BFO 4.0 0.0 78.8 0.0 0.001 TL 185.70 PV Pipe: 54 FIXED PRESSURE LOSS DEVICE BFI 4.0 0.0 83.3 0.0 4.5 psi, 689.5 gpm BFO 4.0 0.0 78.8 0.0 Pipe: 55 -689.5 10.374 PL 2.83 PF 0.0 BFI 4.0 0.0 83.3 0.0 2.6 120 FTG B PE 1.2 UG1 1.2 0.0 84.5 0.0 0.001 TL 24.13 PV Pipe: 56 -689.5 10.275 PL 85.00 PF 0.2 UG1 1.2 0.0 84.5 0.0 2.7 140 FTG 2ETG PE 2.2 SOURCE -4.0 SRCE 87.0 (N/A) 0.001 TL 225.80 PV NOTES (HASS): (1) Calculations were performed by the HASS 7.9 computer program under license no. 4903012830 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.053 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 26.4 ft/sec at pipe 30. (4) PIPE FITTINGS TABLE Pipe Table Name: MOST.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 10/9/20085 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PAGE: A MATERIAL: SCH.40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D F Ell Tee LngEll ChkV1v BfyVly GatV1v AlmChk DPV1v 45E11 H Q I S U V W 22/Ell 11gE11 Couplg FM90E1 FM45E1 FMTee FMRunT 1.049 2.00 5.00 2.00 5.00 0.00 0.00 0.00 0.00 1.00 0.50 0.30 1.00 6.00 5.00 9.00 0.00 1.610 4.00 8.00 2.00 9.00 0.00 0.00 0.00 0.00 2.00 1.00 0.50 1.00 8.00 6.00 12.00 0.00 PAGE: B MATERIAL: SCH.10 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D F Ell Tee LngEll ChkV1v BfyVly GatV1v AlmChk DPV1v 45E11 4.260 6.357 8.249 10.374 H Q I S U V W 22/Ell 11gE11 Couplg FM90E1 FM45E1 FMTee FMRunT 13.20 26.30 7.90 29.00 15.80 2.60 36.90 39.50 6.60 3.30 1.60 1.30 18.40 11.90 31.60 0.00 17.60 37.70 11.30 40.20 12.60 3.80 37.70 41.50 8.80 4.40 2.20 1.30 22.60 13.80 42.70 0.00 20.00 38.90 14.50 50.00 13.30 4.40 45.60 0.00 10.00 5.00 2.50 1.10 24.50 14.50 43.40 0.00 24.60 56.00 17.90 61.60 21.30 5.60 0.00 0.00 12.30 6.20 3.10 1.10 29.10 16.80 56.00 0.00 PAGE: D MATERIAL: DI -52 HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D F Ell Tee LngEll ChkVly BfyVly GatV1v AlmChk DPV1v 45E11 H Q 22/Ell 11gE11 10.275 31.30 71.10 22.70 78.20 27.00 7.10 0.00 0.00 15.60 7.80 3.90 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 10/9/2008S 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble 0 0 OlW 0 Ur r1 w 0 r-1 G4 0 0 0 140.00 psi Resid: 0 0 LID r -I rn a)L.r) • a) u, rn • m m C (1)• � of m Rao E U cn a) a) N --I • E HI ;11'0 W 0 a) XI • H �-1 a m - N -1 0 0 • 0 v) (i) RI co b' • yma) • aoo,< a) a) bi O 0 g %/ rl N 0 0 r -I 0 o O 0 0 0 0 0 0 0 N 0 CO lO C7 r:4 C7W waw inEnpaIII -R.,w-.-1— 0 0 d� N 0 0 .41 0 0 0 0 0 0 N N 0 0 0 0 Lr) 0 0 O 0 m 0 0 N FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 10/9/20085 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble WATER SUPPLY CURVE 132+ \ I \ I \ I \ 120+ \ I \ I \ I \ 108+ \ I \ I \ I \ P 96+ \ R 1 \ E I \ S X \ S 84+ \ U I \ R 1 \ E I \ 72+ \ ( I \ P 1 \ S I \ 160+ \ ) I I I \ \ \ 48+ \ I \ \ 1 \ 36+ \ \ \ \ 24+ LEGEND \ "* <-20.0 psi @ 10900 gpm 1 X = Required Water Supply " Flow Test Point 87.00 psi @ 939.5 gpm " 12+ " 0 = Available Water Supply 138.71 psi @ 939.5 gpm II II II 0++-+- +- + + + + + + + 32004800 6400 8000 9600 11200 12800 14400 16000 FLOW (GPM) FI E ALARM SYSTEM ADDIT TUKWILA, WASHINGTON T NUM RE S E ET TITLE --n1 SYST =M I \ FO MATT O FA -02 TYDICAL WIRI\G A\D vIOUNTING DETAILS 93 SYST =M CALCULATIONS AND SIN G LE LINE DIAGRAM n4 FIRE AL. M SYSTE vi PLAN - WithoutComments 0 As Noted In Red O Per The Attached Letter SHEET INDEX These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which cio not authorize violations of adopted standards and ordinances The responsibility for the adequacy of design ,-esfs totally with the designer. Additions, deletions i revisions to these drawings after this date will void this:. cceptance and will require a resubmittal of r`vised drawings for subsequent approval. Final acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 11- By: s� l TUKWILA FIRE DEPAR ih TFf fl �-=,a_--2 ;� O - and . ,..,....... Com._ v't,<�I 7� ��01 t.iifs i iF e r 6 9d it BL',Oa id exact 2d/� r. ss for shut- t�u`Ji 1.:1,7 , � .so in or restoration approval. IR- SCHED UL A\ COI\ DUIT FILL CHA SYMBOL DESCRIPTION WIRE DESIGNATION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C D P \, Vr STROBE SYNC DATA LINE -ADDRESSABLE LOOP DEVICE POWER - 24VDC STROBE CIRCUIT- FEED STROBE CIRCUIT - RETURN SPEAKER CIRCUIT - FEED SPEAKER CIRCUIT - RETURN REMOTE INDICATION LIGHT TWISTED PAIR WITH SHIELD TWISTED PAIR WITH SHIELD TWO TWISTED PAIR W/ SHIELD TWISTED PAIR W/ SHIELD TWISTED PAIR TWISTED PAIR TWO #14 #16 #16 #14 #14 #14 #14 #18 FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS TWO TWO TWO ;ONDUCTOR VOLTS WIRE SIZE TYPE DIMENSIONS AREA 600V 600V 300V #12 AWG #14 AWG #18 AWG THHN/THWN THHN/THWN TWISTED FPL TW CABLE .244 0.D. .0467 .210 0.D. .0346 .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1 /2" 3/4" 1-1/8" 1-1/2" 2" .12 SQUARE INCH .21 SQUARE INCH .34 SQUARE INCH .60 SQUARE INCH .82 SQUARE INCH 1.34 SQUARE INCH IGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLE_ BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORI-Y HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE FERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NEPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS LASING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSENBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 F-) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY 1 15 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 3 FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S BOX CEILING 12 y FIRE ALARM STROBE 4 3 3 ZR -MC -CW SIEMENS 4S BOX CEILING HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD ®D DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N /A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND 00 Z. V) co Cr RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION J SHOP DRAWINGS DATE N. 2aaa<a UNIQLO SPACE #718 NORDSTROM 3 LEVELS ;71,27s maces PAT-UVrnc JCPenney •S 1 � i a1 F_Rt_ 1 • v4 SEARS SITE PLAN PAID 04) P^/ 13 2017 RA LA FIRE co Owa) T 0) oD5z �0 cc U� w ~� 0D LC cm- . O O pi, 0) /SCALE: NOT TO SCALE Z 0 0 z DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 / 15/ 17 V\ n JOB NUMBER: 26915-1) BACKROUND PLAN PROVIDED BY: SHEET FA -0 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved \ 01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDI11ONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-601Z DEDICATED EMERGENCY TUBE OUTLET SAMPLING TUBE INLET— SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE FOR ADDITIONAL SPECF:C'trONS sFE PRODUCT DOCIa'E'1TA11 I. 'CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL �+ OR PPEVIOUN ADDRESSABLE DEVICE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE alta! 0 GRD N L PAD -3 0 00 INPUT UPUI TROUBLE NAC1 NA.C2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 CISa [Mar 3.6k EOL 0 0 (-) (+) 2 NAC 3 CIRCUIT NAC 2 CIRCUIT NAC 4 CIRCUIT CEILIN TILE HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (-) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE o (+) FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) 1 0 0 SUPERVISED SWITCH ------- GROUND-13 - -- GROUND-13 In 0 0 HTRI-R OSTATUS LED Co 0 N.O. 0 COM 0 N 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. MUSIC 0 HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL LAC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4.OA @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERATURE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR 111 NEXT DEVICE OR END ❑F LINE DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE —) FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > REAR VIEW > TO NEXT 1 1 ADDRESSABLE DEVICE (+) SMOKE DETECTOR WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE HFP-71 TB1 0000®00 00 NO COM 2 NC EOLR v v V 470 0 00 TO FAN SHUTDOWN r7/ TO NEXT ADDRESSABLE DEVICE 0 00 B HTRI-R 0 NO ® COM B NC ® 0 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT O O O O • TO NEXT DEVICE -CADDY BAR SMOKE DETECTOR — -SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved IrZa ft4 a 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: SWITCH + — INPUT LED TSM -1 0 00 TO FAN SHUTDOWN r7/ TO NEXT ADDRESSABLE DEVICE 0 00 B HTRI-R 0 NO ® COM B NC ® 0 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT O O O O • TO NEXT DEVICE -CADDY BAR SMOKE DETECTOR — -SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved IrZa ft4 a 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE N Ln 2 aaaa< J w 0 cos �� 4:k co z Wco 2 OUB �— ,f)° --z O � a JIG Q z (1)W C/) 2 z' .1 cc w U Lu D2'5 CCOD LL- WH- O CO N U �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:1 1 / 15/ 17 BACKROUND PLAN PROVIDED BY: \ OB NUMBER:26915-1} r SHEET \ FA -02 i Q m 0 O W L.L O_- --) Y FIRE ALARM BOOSTER Project: UNIQLO - WSCM T.I. Panel: NEW PAD -3 REMOTE Date: November 15, 2017 Module/Device POWER BOOSTER Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 3425 Total(A)= 15 Total(B)= 3565 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 3565 Total current ratings converted to amperes (line D x .001) 0.015 3.565 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.2969645 Add lines G and I Total Standby and Alarm AH 0.6569645 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.7883574 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: UNIQLO - WSCMT T.I. Panel: NEW PAD -3 REMOTE BOOSTER POWER SUPPLY Date: November 15, 2017 Wire Resistance 2.58 CURRENT TOTAL= 3425.00 4 2 DEVICES ZH-MC-CW @15cd ZH-MC-CW @3Ocd ZH-MC-CW @75cd ZH-MC-CW @95cd ZR -MC -W @15cd ZR -MC -CW @15cd 9 87 131 222 292 64 69 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 348 393 0 0 0 138 879= 14 2 8 DEVICES ZH-MC-CW @15cd 71 -MC -CW @30cd al -MC -CW @75cd 71 -MC -CW @95cd ZR -MC -W @l5cd ZR -MC -CW @15cd 10 87 131 222 292 640_ TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E ) EOL Voltage 0 262 0 0 0 552 814 14 226 233 22.97 (WL*2)*.(R/ft) (Total Cct Load) (E= I * R) 24-E) 23.02 (WL*2)*(R/ft) (Total Cct Load) (E=1*R) 24-E) 879 1.17 0.88 1.03 22.97 814 1.20 0.81 0.98 23.02 6 2 DEVICES ZH-MC-CW @15cd al -MC -CW @30cd ZH-MC-CW @75cd ZH-MC-CW @95cd ZR -MC -W @15cd ZR -MC -CW @75cd 8 131 222 292 64 200 TOTAL mA= 1732. 14 0 1332 400 Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E ) EOL Voltage 246 21.80 (WL*2)*(R/ft) (Total Cct Load) (E=1*R) 24-E) 1732 1.27 1:73 2.20 21.80 CALCULATIONS FACP `ADD: Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 FDBZ492-HR 3 0.0635 0.0635 0.064 0.192 HTRI MODULE 4 0.009600 0.0096 0.021 0.084 0.0731 Amps 0.276 Amps 120VAC DEDICATED ( BY OTHERS) 3S S3-1 S3-2 S3-3 S3-4 75Cd 75Cd 75Cd 75Cd S3-5 S3-6 75Cd 75Cd S2-1 S2-2 S2-3 S2-4 30Cd 30Cd 15Cd • 15Cd S2-5 15Cd S3-7 75Cd S2-6 15Cd S3-8 75Cd EOL S3 S2-7 15Cd S2-8 15Cd J EXISTING TENANT J -BOX D S1-1 S1-2 S1-3 S1-4 30Cd 30Cd 15Cd 15Cd D,I HT -R 21 0 11-.7§F-11 D S1-5 S1-6 S1-7 15Cd 15Cd 15Cd SINGLE LINE DIAGRAM S1-8 15Cd S1-9 30Cd S2-9 15Cd EOL S1 S2-10 15Cd EOL S2 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved a V) co 0\ 743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE cN 10 co 1` zwo H<o) o 5z -� Wcco ¢z aw W D2" OD o co N SCALE: NOT cc 0 0 W z J W J 0 z o z 0 CJ) Cr) TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:1 1 / 15/ 17 BACKROUND PLAN PROVIDED BY: \OB NUMBER:26915-1} 1 SHEET FA -03 COL •.. 13 d 3 • :I E • S1-7 15Cd , ' I I • •—, • ; I\ / .11 S1i6 PD e—I HT -R TSM „lS ilil ....1! .., /-----f :1 ..i .1: ,-:, - .... -i ----- S--- --.1 --: S1-9 3OCd EOL S1 TO EXISTING TENANT JUNCTION BOX EMS 1 E S1-2 30Cd T. 43 X 4 S1-1 3QCd ;1- E3 / 7/ \„,‘•••• 104 CASE; \-VRAT-.) 2-8 " X 241 . . • i! • : I E --- • ! z„- „ :• 0' LJ E EE'f' Z S3-2 - 75Cd IGH D HT -R I TSM _I 11IGH..,___ S2-1- - • 30Cd 1 1 X •: ; I 1:5'LS11 111Cd 16Cal • HI S3-1 1 TSM .„1 -6 16Cd S 51;;14 2C -8d if= !11, $2-9 ;•7„. 15Cd ;• I1 , 1 HIGH HIGH I 75Cd HIGH HIGH C7 Oli\ FLAG NOTES: HELD LOCATE RELAY MODULE_FOR BACKGROUND MUSIC INTERFACE. COL, DUCT DETECTOR, RELAY MODULE FOR FAN HUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL IAND FIRE ALARM CONTRACTORS. FIELD LOCATE SIEMENS PAD -3 BOOSTER !OWER SUPPLY FOR STROBE POWER. AC ¶OWER BY EC FROM DEDICATED, LOCKED OUT ?OA, 110VAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. M • S3-3 75Cd 12_ (---47-- Lecer IX =1 X L -P-'•0_•.--•31- ) IILLL IlL 11! I / I S3-4 75Cd :1 I =1E' (1-•:-‘1 HL S3-6 75Cd 61 11 S3-5 75Cd FIRE ALARM SYSTEM PLAN S3-7 75Cd „ •-• I I•• 7/ s3-8 75Cd, i ., , • 1,7?. - • • y EOL S3 • - • i ,'"-- - -COL • . ..• -- • —COL = . , i;•; .1 : • i • I : I • „ : Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 7/-' • 1 I 11,111I1 z 1'0 co 743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE N Lt) 2 <<<<< L1J03 Z w OD 0 0 4:1; FIE < 0 ma- Z (i) 0 — 0 0 ;c >6. w z cc cn = (f) Z w < w w< cc cm 00 ‘CALE: 3/1 6"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1/15/17 BACKROUND PLAN PROVIDED BY: .JOB NUMBER:26915-1i SHEET ( FA -04 ..) SHEET NUMBED FILE COPY SHEET TITLE SHEET INDEX T MOBLE FIRE ALARM SYSTEM TUKWILA, WASHINGTON FA -01 SYSTEM I\FORMATION FA -02 TYPICAL DETAILS - WIRING A \D MOUNTING FA -03 FIRE ALAS M SYSTE \A FLOICH PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), MISER, SITE PLA\ 1 Without Comments n As Noted In Red (1 Per The Attached Letter t hese plans have h.- ^r r: j �, T!_.=, Tulcilita Fire Prevention Bureau tor c c :..:. standard omissio^y h SttanUE., ci r adequacy o. r i !this resubmittal or 1, Final accap.r. ncC ..: _ <''j' l ' i relri test and inspection b` rile Tukwila Fife Prevention Bureau. Date: /0- 3- 018 731 ...]i -i- nt city adopted 'or the r r. ..::ngs atter nt Epproval. By: A1/) sI FUKWILA FIRE DEPARTM .N8 Please call: 575-4407 and give this job No. O $ - F- 9-7. and exact address for shut. clown or restoration anoroval. 1 A NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testinrj, r41;7 Because of increased demand our inspectors' schedules ire booked 3-7 days ahead. Therefore, you will need to call 206-575.1407 to schedule your inspections a minimum of 48 hours in advance of the date you want an insceclion. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TW❑ 4414 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO 1#16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR \d/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR 1414 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COIVPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT ANC DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) VIHERE THE CABLE IS INSTALLED QUANTITY 2 1 6 1 EX SYMBOL DESCRIPTION SYMBOLS LEGEND MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD a DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE D DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -CW SIEMENS SET -MC -W SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM SET -HMC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. L FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING 111 Q c FIRE ALARM STROBE (WALL MOUNT) FIRE ALARM SPEAKER (CEILING MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. Y B WP FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD ❑M MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD JUNCTI❑N BOX F,B.❑. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.❑. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.D.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAID OCT - 7 2006 Tukwila Fire 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 LLJ Ct w LLI -J UJ REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 00 0 I` 0 0 z aaCCC 00 co -11:39 W mZ W c mmmi (5f- 0 O Uc W co �CALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 10/07/08 Ti9n BACKROUND PLAN PROVIDED BY: JOB NUMBER:54554 / \r)6( SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC 0 DUCT DETECTOR LOCATION END OF LINE DEVICE(3,6K 1/4W) SUPERVISED SWITCH GROUND 0 N) 0 0 HTRI—R OSTATUS LED 00 0 N.0 r- 0 0 COM N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. o O �J TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL KALE (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING TUBE INLET SAMPLING—\ TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE LI -AC POWER SOURCE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE Sim STOP IF LAST DEVICE(+)- FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE (-) END OF LINE DEVICE (3.6K 1/4W) RELAY CONTACTS (4.OA @ 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 mA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0,02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. 0 + TB1 5 0 0 0 0 123456 HCP TB2 es.�+g00 6 5 4 3 2 1 0 0 / / SUPERVISED/ SWITCH GROUND / NOTE: 0 © HTRI—D STATUS LED 0 NOT USED 0 1 0 FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL `ABEL SCIE(FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC 0 000 0 PAD -3 0 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 000 0 24K n + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE tu END OF LINE DEVICE 3.6K 1/4W) - UPERVISED SWITCH 2 —Z NAC -4 NAC -3 NAC -2 NAC -1 1' FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE E DEVICE LOOP NOT USED REMOTE DEVICE LOOP .�. 0- 0 0 0— FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS iw EOL TEM -1 0 0 • • • e TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE:NONE FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) 10 () STROBE SPEAKER 0 0 EARTH GROUND -304+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE 6) STROBE-) (+) (-) STROBE SPEAKER SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY R --''�77 _✓Y 0 0 : 4S DEEP BOX IN/ 1-1/2" I EXTENSION RING ((SPEAKER STROBE) 4S BOX I (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER�T�IN TEMPERATU +32' F (0' C) TO 100' F (33E8' C) HUMIDITY: 9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —� DEVICE IS USTED FOR AIR VOLOaTY APPLICATIONS OF 300-4000 FTA4IN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR r D8-11 STANDARD SMOKE DETECTOR BASE rFROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE 1 DATA IN (-) > DATA IN(+)> HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID —\ CEILING SPEAKER SUPPORT TILE BRIDGE ,-- 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTI❑N BOX MOUNTED ON CEILING FLEX \ JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT %L1 O O I TO NEXT DEVICE / / / / 0 0 CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SUSPENDED ILLUMINATED CEILING SCALE:NONE DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z DESCRIPTION SHOP DRAWINGS DATE 10/07/08 2 CCCCa co co '- J 07 W �z WW1 m `n z z O ccvco �— �co O g LL co 1— J �CALE: 1 /8"=1' z z 0 0 z 0 z J 0_ DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:10/07/08 BACKROUND PLAN PROVIDED BY: \0B NUMBER:54554 SHEET FA -02 EOL—S1 20.06V FACP EX D,I 2I 15 C 2S,2vx c) -2S, 30 C 2S,2V 2S,2V i1 bl L 30 C 30 C NORTH T MOBLE WESTFIELD SOUTHCENTER MALL SCALE 118"=1' FLAG I\ OTES: S: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATI❑N SUBMITTAL FOR L❑CATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACT❑R, WIRED BY ELECTRICAL CONTRACTOR, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESION SYSTEM, FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 2OA, 110 VAC BRANCH CIRCUIT, PLANS NOT APPROVED DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z DESCRIPTION SHOP DRAWINGS DATE 10/07/08 2 CCCCC CO co —10'; O) wre re0 LA- W co -1 zz OCCvu, E- w o �g Li- co t`_ W LL 6ALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:10/07/08 BACKROUND PLAN PROVIDED BY: \0B NUMBER:54554 C SHEET FA -031 D 11135 1470 (r) 0 CO <0 FiLd 1140 TOUT 1111111111111m scum 14601 ILLUMINATIONS 114751 STAEs-:BUCI<S NORTH 1 111551 11160 11440 • ry c,r) .J1 _J 0 KIDS FOOTLOCKER 1200 11430 111 OAP BODY 12101 SYSTEM CALCULATIONS -r 4.,f--)! _J LLI -J 114101 ELTC7RICA.L RM 1851 1490 . . II RECYCLING II STORAGE 11495 1 1 RISER ROW LOADING DOCK GUESS WESTFIELD SOUTHCENTER WALL CHEESECAKE FACTORY R3 LY uJ 0 0 0 0 ›- rTh 123. (r c 0 1 v251 SCALE 1132'1=1' 30 C 30 C 30 C 15 C 15 15 15 EOL -S1 FA -$31:1X FACP EX 4» DJ 21 IFORNIA MAC GRILL RL BATTERY SIZING CALCULATION Notification Appliance Circuit Detail I PROJECT: IWESTFIELD SOUTHCENTER MALL TENANT IT MOBLE !Wire Resistance 1.62 Date: 1 October 7, 2008 1 CURRENT TOTAL= 550 1 IS1 CIRCUIT: ' i 1' • , a QTY Device Type 'Alarm Current Alarm Total Wre Size Wire Length a Voltage at EOL Circuit Total a 3 3 0 0 0 !,SET -MC @15CD I SET -MC @30CD 1SET-MC @75CD 1SET-MC ©110CD 1SET-HMC-C©115CD 0 LSET-HMC-C©177CD 0 !SET -HMC @135CD 0 SET -HMC ©185CD 641 192 Total Wire Resistance ( R ) 981 294 (WL*2 )* (R/ft) 0.62 1751 0 Total Device Load, Amps (1) , 0.55 _,.......__ ....,_ _..._ 233 0 , (Total Cct Load) 3181 0 a Voltage Drop ( E ) 0.34 4451 0 i , (E= I * R) 3181 0. i EOL Voltage j 20.06 4451 0 j (20.4 - E) F 1 IZ-MC©15CD 64 64 0 Z-MC©30CD 981 0ISET-MC-CW©110CD 1 233 DEV10ES=17 TOTAL mA=I 5801 12 191 20.059638 I Notification ADDliance Circuit Detail !PROJECT: 'WESTFIELD SOUTHCENTER MALL 1 1 TERNANIT MOBLE Date: 1 October 7, 2008 CIRCUIT:SPEAKER CIRCUIT Wire Resistance 2.58 CURRENT TOTAL=110.8 Device Type Alarm Current Alarm Total Wire SiZB Wire Length Voltage at EOL 1 Circuit Total 6 170.7V1/8 1 1.8 10.8 0 0 01 0 0 01 0 0 0 Oi 0 01 0 0 0 0 0! 0 0 1. 0 0 0 01 1 0 DEVICES= 1 TOTAL m - 10.8 0 14 Total Wire _Resistance OR ) 0.99 ( WL* 2 )* (Rift) 1 Total Device Load, Amps (1) 0.01 (Total Cct Load) Voltage Drop ( E ) L (E= I * R) EOL Voltage (20.4 - E) 20.38935595 co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 z 0 c7) 5 uJ uJ (f) LU LLI REV. BY: T MOBLE CRAZY 8 FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS LLI 1 5/15/08 I- Current Load: Standby: Alarm: CI Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 AD2-P 1 0.0635 0.0635 0.064 0.064 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R 2 0.009600 0.0096 0.021 0.042 SET -MC @15CD 0.064 HTRI-D 0.001600 0.0035 SET -MC @30CD 0.098 ICP -B6 0.005 SET -MC @75CD 4 0.175 0.700 SET -MC @110CD 0.233 SET-HMC-C@115CD 0.318 SET-HMC-C@135CD 0.318 0.0731 Amps 0.106 Amps SET-HMC-C@185CD 0.445 ZR -MC @15CD 1 0.064 0.064 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 0.098 HCP 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.03 Amps 0.794 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.794 Amps For 5 Minutes= 0.067 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 0.983 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 0.983 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION Notification Appliance Circuit Detail I PROJECT: IWESTFIELD SOUTHCENTER MALL TENANT IT MOBLE !Wire Resistance 1.62 Date: 1 October 7, 2008 1 CURRENT TOTAL= 550 1 IS1 CIRCUIT: ' i 1' • , a QTY Device Type 'Alarm Current Alarm Total Wre Size Wire Length a Voltage at EOL Circuit Total a 3 3 0 0 0 !,SET -MC @15CD I SET -MC @30CD 1SET-MC @75CD 1SET-MC ©110CD 1SET-HMC-C©115CD 0 LSET-HMC-C©177CD 0 !SET -HMC @135CD 0 SET -HMC ©185CD 641 192 Total Wire Resistance ( R ) 981 294 (WL*2 )* (R/ft) 0.62 1751 0 Total Device Load, Amps (1) , 0.55 _,.......__ ....,_ _..._ 233 0 , (Total Cct Load) 3181 0 a Voltage Drop ( E ) 0.34 4451 0 i , (E= I * R) 3181 0. i EOL Voltage j 20.06 4451 0 j (20.4 - E) F 1 IZ-MC©15CD 64 64 0 Z-MC©30CD 981 0ISET-MC-CW©110CD 1 233 DEV10ES=17 TOTAL mA=I 5801 12 191 20.059638 I Notification ADDliance Circuit Detail !PROJECT: 'WESTFIELD SOUTHCENTER MALL 1 1 TERNANIT MOBLE Date: 1 October 7, 2008 CIRCUIT:SPEAKER CIRCUIT Wire Resistance 2.58 CURRENT TOTAL=110.8 Device Type Alarm Current Alarm Total Wire SiZB Wire Length Voltage at EOL 1 Circuit Total 6 170.7V1/8 1 1.8 10.8 0 0 01 0 0 01 0 0 0 Oi 0 01 0 0 0 0 0! 0 0 1. 0 0 0 01 1 0 DEVICES= 1 TOTAL m - 10.8 0 14 Total Wire _Resistance OR ) 0.99 ( WL* 2 )* (Rift) 1 Total Device Load, Amps (1) 0.01 (Total Cct Load) Voltage Drop ( E ) L (E= I * R) EOL Voltage (20.4 - E) 20.38935595 co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 z 0 c7) 5 uJ uJ (f) LU LLI REV. BY: Z DESCRIPTION SHOP DRAWINGS LLI 1 5/15/08 I- <1( CI 2 <<<<< ‘C' ALE: 1 /8"=1' DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE: 10/07/08 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved .JOB NUMBER:54554 i )f' SHEET FA -04 E f) /6" Reliable Model "G" Riser Check Valve 1 0" Victaulic #750 /Butterfly Valve n WILKINS 10" 350 DAG n Vertical Backflow Preventer [X\ 10" Victaulic #750 Butterfly Valve 1 0" Flange 4. @ I '-2" AFF \ FF @ 0'-0" ..0._ 10" D.I. \ �L @ -4'-0"± S stem T4 Riser Assembl Detail N.T.S. Source T Io 7, UP 10" x 9'-6"7 -61 8H /4.@2'-O"AFF / t- c o;: DN 6" x 1 2'-6' 3L8" 1 2'-0" FOW 4" x I I'- I 0"±6" 2'-0" 5'-0" FOW 1 r FOW @ 1 4'-6" AFF 4.08 R �" 3'-8" € OB o 0 L 4" x 85'-0":_t6" 4. @ 14'-6" AFF 9'-9Y4' TOLCO FIG. 25 SURGE RESTRAINER TYPE 1 - FOR I" AND 1/4" PIPE AND HANGER TYPE 2 - FOR Iy2' AND 2" PIPE AND HANGER TOLCO FIG. 25 15 DESIGNED TO BE USED ONLY WITH TOLCO BAND HANGERS FIG. 200 AND 2NFPA TO RESTRAIN THE UPWARD MOVEMENT OF PIPE AS IT OCCURS DURING SPRINKLER HEAD ACTIVATION OR SEISMIC ACTIVITY SYMBOL = FIGURE 25 SURGE RESTRAINER FOR STEEL OR CPVC PLASTIC PIPE 8'-2Y4" UL HILTI KWIK BOLT 3 ANCHOR ICC REPORT #ESR -1385 MIN. OF 3,000 PSI CONCRETE MIN. 3 1/4" CONCRETE OVER MAX. 3" METAL DECK 3/8" ANCHOR W/20# TORQUE: TENSION -7395#, SHEAR=750#* 1/2" ANCHOR W/40# TORQUE: TENSION=440#, SHEAR=750#* •SHEAR LOADS HAVE BEEN REDUCED BY 20% FOR SHEAR THRU THREADS 1/4" MIN ROD COUPLING THREADED ROD PIPE ROD BOLT IMBED SIZE DIA. LGTH DEPTH I" 3/8" 3 3/4" 2 1/4" 1 1/4" 3/8" 3 3/4" 2 1/4" 1 1/2" 3/8" 3 3/4" 2 1/4" 2" 3/8" 3 3/4' 2 1/4" 2 1/2" 3/8" 3 3/4' 2 1/4" 3" 3/8" 3 3/4' 2 1/4" 4' 3/8° 3 3/4' 2 1/4" 6" 1/2" 3 3/4' 2 1/4" 8" 1/2" 3 3/4" 2 1/4" HILTI FIG. LH OR TOLCO FIG. 200 HANGER RING UL 04/2007 COSCO STANDARD HANGER 13 MDL 0 cn CV 0 i" - B_ 4'- 1.1" FOW 0 7_1" N .FOA FOW O 0-6 0 I 00 �LXC 14'-i Iy2" . \ \ L\; S5 u J B ice; 1 k IFOW O m .N 0 w 4'- I I%2" . 2'-!0" ti Si FOW i� CD 1' mommf Now. 1•00 0-41¢ II ;l t . /•' _ 0=10 t_ 0100.0 • .-, 0 .o— • • • FOS m3 FOW FOW '.l f• i• : t; 1,1 rriV • I CONSTRUCTION NOTES: 1) PIPE: THREADED: STEEL, SCH 40, BLACK, IMPORT. GROOVED: STEEL, SCH 10, BLACK, IMPORT. 2) FITTINGS: GROOVED: STAR STANDARD - ORANGE PAINT FINISH THREADED: STAR D.I. 3) GROOVED COUPLINGS: STAR RIGID C-4 UNLESS MARKED WITH AN "P', WHICH ARE TO BE STAR FLEXIBLE C-3 LW - ORANGE PAINT FINISH 4) HANGER MATERIAL: ALL HANGER MATERIAL IS TO BE FINISHED BLACK OR STANDARD 0 GENERAL NOTES: ) I) SYSTEMS ARE DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF N.F.P.A. 13-2007 ED., THE CONTRACT DOCUMENTS, AND THE CITY OF TUKWILA. CRITERIA: OCCUPANCY: ORDINARY HAZARD GROUP II. ORDINARY HAZARD GROUP II SPRINKLER SPACING: 130 ft2 MAX. 2) COSCO'S POINT OF CONNECTION IS AT EXISTING SYSTEM AS SHOWN. 3) ALL PAINTING OR PREP OF FIRE SPRINKLER PIPING ( IF REQ.. ) TO BE DONE BY OTHER. 4) ALL WIRING OF SYSTEM DEVICES IS BY OTHER. 5) OWNER IS RESPONSIBLE TO ASSURE THAT THE STRUCTURE, AS IT IS SHOWN ON THE CONTRACT DRAWINGS, CAN ADEQUATELY SUPPORT THE FIRE SPRINKLER PIPING. NO AUXILIARY DEVICES OR ATTACHMENTS SHALL BE PROVIDED BY COSCO TO SUPPLEMENT THE STRUCTURE. 6) OWNER IS RESPONSIBLE TO PROVIDE ADEQUATE HEAT TO MAINTAIN 40°F. MINIMUM AT ALL TIMES. 7) OWNER IS RESPONSIBLE TO ARRANGE FOR THE PERIODIC INSPECTION, TESTING, AND MAINTENANCE OF THESE FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF N.F.P.A. 25-2002 ED., BY QUALIFIED PERSONNEL COMMENCING AFTER WARRANTY PERIOD HAS EXPIRED. THE FIRM THAT DESIGNED AND INSTALLED THE SY5TEM(5) IS BEST QUALIFIED TO PROVIDE THE ONGOING LONG TERM TESTING, MAINTENANCE, AND SERVICING. 8) COSCO TAKES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE OR CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIED OR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO FIRE PROTECTION. 1 SEE PLAN FOR LENGTH REMOVE EXISTING SPRIG --"� INSTALL NEW 1x0-6 NIPPLE ADJUSTABLE HUB MAX. 2'-O" MOUNTING BRACKET EXISTING BRANCH LINE MAX 2'-0" "FLEXHEAD" FLEXIBLE DROP CORRUGATED STAINLESS STEEL —' BRAIDED HOSE (4'-O") CEILING ADJUSTABLE HUB MOUNTING BRACKET 1" aSEE PLAN FOR LENGTH CT, SEE PLAN FOR LENGTH 1 w tY i O LL _"FLEXHEAD" FLEXIBLE DROP CORRUGATED STAINLESS STEEL BRAIDED HOSE (4'-O") CEILING REMOVE EXISTING SPRIG INSTALL NEW 1x0-6 NIPPLE EXISTING BRANCH LINE 1 ADJUSTABLE HUB MOUNTING BRACKET B TYPICAL ARMOVER TO NEW SPRINKLER HEAD N.T.S. T—Mobile: SCALE: Y4" = 1 '-0" t t CCE TED Without Comments As Noted In Red Per The Attached Letter 1 nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions these drawings atter this date will void this acceptance :-And will require a resubmittal of revised drawings for subsequent approval. Final -acceptance is subject to field test and inspection IA The Tukwila/Vv"iFire Prevention Bureau. Date: /0 9-02 By: Jt IMPORTANT NOTICE Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. TUKW1LA FIRE DEPARTMEhi't Please call: 575.4407, and give this job No. og-S-(1-761 and exact address for shuts down or restoration aoi roval, NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic test approval. FILE COPY r, -rt Of SPRINKLER HEAD LEGEND : SYMBOL S/N ORIFICE NPT K -FACT. HEAD FINISH PLATE FINISH TEMP. (VAN. Reliable Model FI FR Recessed SSP 1/2' 1/2' 5.6 Chrome Chrome 155° 6 Reliable Model G4A Concealed SSP 1/2' 1/2' 5.6 Bronze White 155° 17 APPROVALS BY: l TOTAL SPRINKLERS THIS SHEET 23 •00 00 00• *00000" "00000• I cosco Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS WASHINGTON OFFICE www.coscofire.com 10910 117TH Place N.E. Kirkland, Washington 98033 call (425) 827-9654 • fax (425) 827-7474 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE • ANCHORAGE License No: COSCOFP 110NM T -Mobile 718 Southcenter Mall, Suite # 1475 Tukwilla, Wa. 98188-2823 e.'"D-1#PAID OCT - 9 2008 Tukwila Fire 42(12g 1/4; — CONTRACT WITH: Hawk Building P.O. Box 2318 Woodinville, Wa. 98072 Contact: Ryan Adkins (425) 273-1583 DRAWING TTTLE T -Mobile: Fire Sprinkler Piping Plan GATE : October, 2008 SCALE : As Noted DRAWN BY : Justin Johnson Mss - 798 1 SHEET NO. FP 1 of 1 718 SOUTHCENTER MALL ASSOCIATED PERMITS 17-F-218 08-F-475 08-S-479 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION 2 ��j,j 8 King Co. Assessor's Tax No.:491 l- -cola �• enc ,n I 101(-- O Imo} Ct818u i -, i8 Floor: ts+ Site Addres . • + h wte Number: Tenant Name: Property Owner's Namel1\10-1-r-o, Il7175-Feili Tct �- Mailing Address: New Tenant? 1:1- Yesl- No CONTACTPERSON-if there are questions abo ut the submittal. Name: CiJftr'f1'J\ &&0' r4' - Company Name: Cl Mailing Address:13'113 134 Ave City Day Telephone: State Zip ZZ9 \AA 98 &I City State Zip E-mail Address:ael ttm ran, Fax Number: Contractor's City of Tukwila ,G� �i� NICET III number: Business License numberDLIS- Y a28 '' Total number of new/relocated devices or sprinkler heads: 113 Valuation of Project (contractor's bid price): $ j ( r UVU Scope of Work (please provide detailed information): 5k Gfi on (`''l rf f aii cki at, (4) deui'c-Q PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. This figure will be Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HA UNDER PENALTY OF P r ' R : Y. FOR THIS PERMBUILDIN r Vii*AS Signature: Print Nam AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY D AGENT: Plan Permit App.doc Date: %1 ie (H" Day Telephone: 06 •(�L/S .22'1 8/22/14 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: T -Mobile 718 Southcenter Mall Permit No.: 08-S-479 Date: October 9, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/ inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more sprinkler heads require hydrostatic test and system isolation if necessary. • These conditions apply to any sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2007 Edition. COSCO FIRE PROTECTION, INC. 15000 WOODINVILLE REDMOND ROAD NE #B800 WOODINVILLE,WA 98072-4502 HYDRAULIC CALCULATIONS FOR T -Mobile 718 Southcenter Mall, Suite #1475 Tukwila, Wa. 98188-2823 FILE NUMBER: 25SS - 7981 DATE: OCT 9, 2008 -DESIGN DATA - OCCUPANCY CLASSIFICATION: Ordinary Group II DENSITY: 0.20 gpm / 1500 sq. ft. AREA OF APPLICATION: 1,669 sq. ft. COVERAGE PER SPRINKLER: 130 sq. ft. Max. NUMBER OF SPRINKLERS CALCULATED: 23 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 689.5 gpm TOTAL WATER REQUIRED (including hose): 939.5 gpm FLOW AND PRESSURE (@ BOR): 689.5 gpm @ 79.4 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: Cosco Fire Protection, Inc. DESIGN/LAYOUT BY: Justin Johnson AUTHORITY HAVING JURISDICTION: City of Tukwila CONTRACTOR CERTIFICATION NUMBER: COSCOFP110NM CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 4903012830) HRS SYSTEMS, INC. TUCKER, GA 30084 TUCKER, GA 30084 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/9/2008S 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble WATER SUPPLY DATA SOURCE NODE TAG SOURCE STATIC PRESS. (PSI) 140.0 RESID. FLOW PRESS. @ (PSI) (GPM) 20.0 10900.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE (FT) S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 S15 S16 S17 S18 S19 S20 S21 S22 S23 L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 10.5 10.5 9.0 9.0 9.0 10.5 10.5 10.5 10.5 10.5 9.0 9.0 9.0 10.5 10.5 10.5 9.0 9.0 10.5 10.5 10.5 10.5 10.5 14.5 14.5 15.0 15.0 14.5 14.5 14.5 14.5 14.5 15.0 15.0 AVAIL. PRESS. (PSI) 138.7 TOTAL @ DEMAND (GPM) 939.5 GPM 250.0 GPM 0.0 GPM 689.5 GPM PRESSURE (PSI) K= 5.60 37.0 K= 5.60 36.6 K= 5.60 23.3 K= 5.60 21.6 K= 5.60 23.0 K= 5.60 24.9 K= 5.60 26.3 K= 5.60 30.3 K= 5.60 37.2 K= 5.60 36.7 K= 5.60 21.6 K= 5.60 23.4 K= 5.60 22.7 K= 5.60 25.0 K= 5.60 26.3 K= 5.60 30.4 K= 5.60 27.7 K= 5.60 27.3 K= 5.60 28.1 K= 5.60 29.1 K= 5.60 32.2 K= 5.60 37.4 K= 5.60 36.9 48.0 48.4 29.3 30.3 32.6 34.7 40.2 48.2 48.6 29.5 30.5 REQ'D PRESS. (PSI) 939.5 87.0 DISCHARGE (GPM) 34.1 33.9 27.0 26.0 26.8 28.0 28.7 30.8 34.1 33.9 26.0 27.1 26.7 28.0 28.7 30.9 29.4 29.3 29.7 30.2 31.8 34.3 34.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 10/9/20085 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) L12 14.5 32.9 L13 14.5 34.8 L14 14.5 40.3 L15 15.0 35.2 L16 15.0 35.5 L17 14.5 36.9 L18 14.5 38.4 L19 14.5 42.6 L20 14.5 48.5 L21 14.5 48.9 M1 14.5 50.5 M2 14.5 50.5 M3 14.5 50.6 M4 14.5 50.7 M5 14.5 51.1 M6 14.5 51.1 TOR 14.5 72.7 BOR 2.0 79.4 M7 2.0 79.5 BFO 4.0 78.8 BFI 4.0 83.3 UG1 1.2 - - - - 84.5 - - - SOURCE -4.0 SOURCE 87.0 689.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/9/20085 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -34.1 1.049 PL 28.38 PF 12.7 S1 10.5 5.6 37.0 34.1 12.7 120 FTG 4E PE -1.7 L1 14.5 0.0 48.0 0.0 0.349 TL 36.38 PV Pipe: 2 -33.9 1.049 PL 28.38 PF 13.6 S2 10.5 5.6 36.6 33.9 12.6 120 FTG 3ET PE -1.7 L2 14.5 0.0 48.4 0.0 0.345 TL 39.38 PV Pipe: 3 -27.0 1.049 PL 30.04 PF 8.6 S3 9.0 5.6 23.3 27.0 10.0 120 FTG 4E PE -2.6 L3 15.0 0.0 29.3 0.0 0.227 TL 38.04 PV Pipe: 4 -26.0 1.049 PL 33.62 PF 10.3 S4 9.0 5.6 21.6 26.0 9.7 120 FTG 5ET PE -2.6 L3 15.0 0.0 29.3 0.0 0.212 TL 48.62 PV Pipe: 5 -26.8 1.049 PL 33.04 PF 9.9 S5 9.0 5.6 23.0 26.8 10.0 120 FTG 3ET PE -2.6 L4 15.0 0.0 30.3 0.0 0.224 TL 44.04 PV Pipe: 6 -28.0 1.049 PL 27.92 PF 9.4 S6 10.5 5.6 24.9 28.0 10.4 120 FTG 3ET PE -1.7 L5 14.5 0.0 32.6 0.0 0.242 TL 38.92 PV Pipe: 7 -28.7 1.049 PL 28.79 PF 10.1 S7 10.5 5.6 26.3 28.7 10.7 120 FTG 3ET PE -1.7 L6 14.5 0.0 34.7 0.0 0.254 TL 39.79 PV Pipe: 8 -30.8 1.049 PL 28.83 PF 11.6 S8 10.5 5.6 30.3 30.8 11.5 120 FTG 3ET PE -1.7 L7 14.5 0.0 40.2 0.0 0.290 TL 39.83 PV Pipe: 9 -34.1 1.049 PL 28.38 PF 12.7 S9 10.5 5.6 37.2 34.1 12.7 120 FTG 4E PE -1.7 L8 14.5 0.0 48.2 0.0 0.350 TL 36.38 PV Pipe: 10 -33.9 1.049 PL 28.38 PF 13.6 S10 10.5 5.6 36.7 33.9 12.6 120 FTG 3ET PE -1.7 L9 14.5 0.0 48.6 0.0 0.346 TL 39.38 PV Pipe: 11 -26.0 1.049 PL 34.75 PF 10.5 S11 9.0 5.6 21.6 26.0 9.7 120 FTG 5ET PE -2.6 L10 15.0 0.0 29.5 0.0 0.211 TL 49.75 PV Pipe: 12 -27.1 1.049 PL 29.83 PF 8.6 S12 9.0 5.6 23.4 27.1 10.1 120 FTG 4E PE -2.6 L10 15.0 0.0 29.5 0.0 0.228 TL 37.83 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 10/9/2008S 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -26.7 1.049 PL 35.83 PF 10.4 S13 9.0 5.6 22.7 26.7 9.9 120 FTG 3ET PE -2.6 L11 15.0 0.0 30.5 0.0 0.222 TL 46.83 PV Pipe: 14 -28.0 1.049 PL 28.46 PF 9.6 S14 10.5 5.6 25.0 28.0 10.4 120 FTG 3ET PE -1.7 L12 14.5 0.0 32.9 0.0 0.243 TL 39.46 PV Pipe: 15 -28.7 1.049 PL 29.08 PF 10.2 S15 10.5 5.6 26.3 28.7 10.7 120 FTG 3ET PE -1.7 L13 14.5 0.0 34.8 0.0 0.255 TL 40.08 PV Pipe: 16 -30.9 1.049 PL 29.12 PF 11.7 S16 10.5 5.6 30.4 30.9 11.5 120 FTG 3ET PE -1.7 L14 14.5 0.0 40.3 0.0 0.290 TL 40.12 PV Pipe: 17 -29.4 1.049 PL 30.04 PF 10.1 S17 9.0 5.6 27.7 29.4 10.9 120 FTG 4E PE -2.6 L15 15.0 0.0 35.2 0.0 0.266 TL 38.04 PV Pipe: 18 -29.3 1.049 PL 30.04 PF 10.8 S18 9.0 5.6 27.3 29.3 10.9 120 FTG 3ET PE -2.6 L16 15.0 0.0 35.5 0.0 0.263 TL 41.04 PV Pipe: 19 -29.7 1.049 PL 28.04 PF 10.6 S19 10.5 5.6 28.1 29.7 11.0 120 FTG 3ET PE -1.7 L17 14.5 0.0 36.9 0.0 0.270 TL 39.04 PV Pipe: 20 -30.2 1.049 PL 28.42 PF 11.0 S20 10.5 5.6 29.1 30.2 11.2 120 FTG 3ET PE -1.7 L18 14.5 0.0 38.4 0.0 0.279 TL 39.42 PV Pipe: 21 -31.8 1.049 PL 28.38 PF 12.1 S21 10.5 5.6 32.2 31.8 11.8 120 FTG 3ET PE -1.7 L19 14.5 0.0 42.6 0.0 0.307 TL 39.38 PV Pipe: 22 -34.3 1.049 PL 28.38 PF 12.8 S22 10.5 5.6 37.4 34.3 12.7 120 FTG 4E PE -1.7 L20 14.5 0.0 48.5 0.0 0.352 TL 36.38 PV Pipe: 23 -34.0 1.049 PL 28.38 PF 13.7 S23 10.5 5.6 36.9 34.0 12.6 120 FTG 3ET PE -1.7 L21 14.5 0.0 48.9 0.0 0.348 TL 39.38 PV Pipe: 24 -34.1 1.610 PL 9.79 PF 0.4 L1 14.5 0.0 48.0 0.0 5.4 120 FTG ---- PE 0.0 L2 14.5 0.0 48.4 0.0 0.043 TL 9.79 PV Pipe: 25 -68.0 1.610 PL 5.46 PF 2.1 L2 14.5 0.0 48.4 0.0 10.7 120 FTG T PE 0.0 M1 14.5 0.0 50.5 0.0 0.155 TL 13.46 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 10/9/20085 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 26 -53.0 1.610 PL 9.94 PF 1.0 L3 15.0 0.0 29.3 0.0 8.4 120 FTG ---- PE 0.0 L4 15.0 0.0 30.3 0.0 0.098 TL 9.94 PV Pipe: 27 -79.9 1.610 PL 10.29 PF 2.2 L4 15.0 0.0 30.3 0.0 12.6 120 FTG ---- PE 0.2 L5 14.5 0.0 32.6 0.0 0.209 TL 10.29 PV Pipe: 28 -107.8 1.610 PL 5.58 PF 2.0 L5 14.5 0.0 32.6 0.0 17.0 120 FTG ---- PE 0.0 L6 14.5 0.0 34.7 0.0 0.365 TL 5.58 PV Pipe: 29 -136.6 1.610 PL 9.73 PF 5.5 L6 14.5 0.0 34.7 0.0 21.5 120 FTG ---- PE 0.0 L7 14.5 0.0 40.2 0.0 0.565 TL 9.73 PV Pipe: 30 -167.4 1.610 PL 4.58 PF 10.4 L7 14.5 0.0 40.2 0.0 26.4 120 FTG T PE 0.0 M2 14.5 0.0 50.5 0.0 0.823 TL 12.58 PV Pipe: 31 -34.1 1.610 PL 10.02 PF 0.4 L8 14.5 0.0 48.2 0.0 5.4 120 FTG ---- PE 0.0 L9 14.5 0.0 48.6 0.0 0.043 TL 10.02 PV Pipe: 32 -68.1 1.610 PL 5.23 PF 2.1 L9 14.5 0.0 48.6 0.0 10.7 120 FTG T PE 0.0 M3 14.5 0.0 50.6 0.0 0.156 TL 13.23 PV Pipe: 33 -53.1 1.610 PL 9.94 PF 1.0 L10 15.0 0.0 29.5 0.0 8.4 120 FTG ---- PE 0.0 L11 15.0 0.0 30.5 0.0 0.098 TL 9.94 PV Pipe: 34 -79.8 1.610 PL 10.52 PF 2.2 L11 15.0 0.0 30.5 0.0 12.6 120 FTG ---- PE 0.2 L12 14.5 0.0 32.9 0.0 0.209 TL 10.52 PV Pipe: 35 -107.8 1.610 PL 5.35 PF 1.9 L12 14.5 0.0 32.9 0.0 17.0 120 FTG ---- PE 0.0 L13 14.5 0.0 34.8 0.0 0.364 TL 5.35 PV Pipe: 36 -136.5 1.610 PL 9.73 PF 5.5 L13 14.5 0.0 34.8 0.0 21.5 120 FTG ---- PE 0.0 L14 14.5 0.0 40.3 0.0 0.564 TL 9.73 PV Pipe: 37 -167.4 1.610 PL 4.58 PF 10.4 L14 14.5 0.0 40.3 0.0 26.4 120 FTG T PE 0.0 M4 14.5 0.0 50.7 0.0 0.823 TL 12.58 PV Pipe: 38 -29.4 1.610 PL 9.94 PF 0.3 L15 15.0 0.0 35.2 0.0 4.6 120 FTG ---- PE 0.0 L16 15.0 0.0 35.5 0.0 0.033 TL 9.94 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 10/9/2008S 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 39 -58.7 1.610 PL 10.29 PF 1.2 L16 15.0 0.0 35.5 0.0 9.3 120 FTG ---- PE 0.2 L17 14.5 0.0 36.9 0.0 0.118 TL 10.29 PV Pipe: 40 -88.4 1.610 PL 5.58 PF 1.4 L17 14.5 0.0 36.9 0.0 13.9 120 FTG ---- PE 0.0 L18 14.5 0.0 38.4 0.0 0.253 TL 5.58 PV Pipe: 41 -118.6 1.610 PL 9.73 PF 4.2 L18 14.5 0.0 38.4 0.0 18.7 120 FTG ---- PE 0.0 L19 14.5 0.0 42.6 0.0 0.435 TL 9.73 PV Pipe: 42 -150.4 1.610 PL 4.58 PF 8.5 L19 14.5 0.0 42.6 0.0 23.7 120 FTG T PE 0.0 M5 14.5 0.0 51.1 0.0 0.675 TL 12.58 PV Pipe: 43 -34.3 1.610 PL 9.04 PF 0.4 L20 14.5 0.0 48.5 0.0 5.4 120 FTG ---- PE 0.0 L21 14.5 0.0 48.9 0.0 0.044 TL 9.04 PV Pipe: 44 -68.3 1.610 PL 6.21 PF 2.2 L21 14.5 0.0 48.9 0.0 10.8 120 FTG T PE 0.0 M6 14.5 0.0 51.1 0.0 0.157 TL 14.21 PV Pipe: 45 -68.0 4.260 PL 0.54 PF 0.0 M1 14.5 0.0 50.5 0.0 1.5 120 FTG ---- PE 0.0 M2 14.5 0.0 50.5 0.0 0.001 TL 0.54 PV Pipe: 46 -235.4 4.260 PL 9.96 PF 0.1 M2 14.5 0.0 50.5 0.0 5.3 120 FTG ---- PE 0.0 M3 14.5 0.0 50.6 0.0 0.014 TL 9.96 PV Pipe: 47 -303.4 4.260 PL 0.52 PF 0.0 M3 14.5 0.0 50.6 0.0 6.8 120 FTG ---- PE 0.0 M4 14.5 0.0 50.7 0.0 0.022 TL 0.52 PV Pipe: 48 -470.8 4.260 PL 8.71 PF 0.4 M4 14.5 0.0 50.7 0.0 10.6 120 FTG ---- PE 0.0 M5 14.5 0.0 51.1 0.0 0.049 TL 8.71 PV Pipe: 49 -621.2 4.260 PL 0.40 PF 0.0 M5 14.5 0.0 51.1 0.0 14.0 120 FTG ---- PE 0.0 M6 14.5 0.0 51.1 0.0 0.081 TL 0.40 PV Pipe: 50 -689.5 4.260 PL 152.25 PF 21.5 M6 14.5 0.0 51.1 0.0 15.5 120 FTG 3ET PE 0.0 TOR 14.5 0.0 72.7 0.0 0.099 TL 218.15 PV Pipe: 51 -689.5 6.357 PL 12.50 PF 1.3 TOR 14.5 0.0 72.7 0.0 7.0 120 FTG TC PE 5.4 BOR 2.0 0.0 79.4 0.0 0.014 TL 90.40 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 10/9/2008S 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 52 -689.5 8.249 PL 5.67 PF 0.1 BOR 2.0 0.0 79.4 0.0 4.1 120 FTG E PE 0.0 M7 2.0 0.0 79.5 0.0 0.004 TL 25.67 PV Pipe: 53 -689.5 10.275 PL 33.50 PF 0.2 M7 2.0 0.0 79.5 0.0 2.7 140 FTG 4EB PE -0.9 BFO 4.0 0.0 78.8 0.0 0.001 TL 185.70 PV Pipe: 54 FIXED PRESSURE LOSS DEVICE BFI 4.0 0.0 83.3 0.0 4.5 psi, 689.5 gpm BFO 4.0 0.0 78.8 0.0 Pipe: 55 -689.5 10.374 PL 2.83 PF 0.0 BFI 4.0 0.0 83.3 0.0 2.6 120 FTG B PE 1.2 UG1 1.2 0.0 84.5 0.0 0.001 TL 24.13 PV Pipe: 56 -689.5 10.275 PL 85.00 PF 0.2 UG1 1.2 0.0 84.5 0.0 2.7 140 FTG 2ETG PE 2.2 SOURCE -4.0 SRCE 87.0 (N/A) 0.001 TL 225.80 PV NOTES (HASS): (1) Calculations were performed by the HASS 7.9 computer program under license no. 4903012830 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.053 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 26.4 ft/sec at pipe 30. (4) PIPE FITTINGS TABLE Pipe Table Name: MOST.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 10/9/20085 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble PAGE: A MATERIAL: SCH.40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D F Ell Tee LngEll ChkV1v BfyVly GatV1v AlmChk DPV1v 45E11 H Q I S U V W 22/Ell 11gE11 Couplg FM90E1 FM45E1 FMTee FMRunT 1.049 2.00 5.00 2.00 5.00 0.00 0.00 0.00 0.00 1.00 0.50 0.30 1.00 6.00 5.00 9.00 0.00 1.610 4.00 8.00 2.00 9.00 0.00 0.00 0.00 0.00 2.00 1.00 0.50 1.00 8.00 6.00 12.00 0.00 PAGE: B MATERIAL: SCH.10 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D F Ell Tee LngEll ChkV1v BfyVly GatV1v AlmChk DPV1v 45E11 4.260 6.357 8.249 10.374 H Q I S U V W 22/Ell 11gE11 Couplg FM90E1 FM45E1 FMTee FMRunT 13.20 26.30 7.90 29.00 15.80 2.60 36.90 39.50 6.60 3.30 1.60 1.30 18.40 11.90 31.60 0.00 17.60 37.70 11.30 40.20 12.60 3.80 37.70 41.50 8.80 4.40 2.20 1.30 22.60 13.80 42.70 0.00 20.00 38.90 14.50 50.00 13.30 4.40 45.60 0.00 10.00 5.00 2.50 1.10 24.50 14.50 43.40 0.00 24.60 56.00 17.90 61.60 21.30 5.60 0.00 0.00 12.30 6.20 3.10 1.10 29.10 16.80 56.00 0.00 PAGE: D MATERIAL: DI -52 HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D F Ell Tee LngEll ChkVly BfyVly GatV1v AlmChk DPV1v 45E11 H Q 22/Ell 11gE11 10.275 31.30 71.10 22.70 78.20 27.00 7.10 0.00 0.00 15.60 7.80 3.90 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 10/9/2008S 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble 0 0 OlW 0 Ur r1 w 0 r-1 G4 0 0 0 140.00 psi Resid: 0 0 LID r -I rn a)L.r) • a) u, rn • m m C (1)• � of m Rao E U cn a) a) N --I • E HI ;11'0 W 0 a) XI • H �-1 a m - N -1 0 0 • 0 v) (i) RI co b' • yma) • aoo,< a) a) bi O 0 g %/ rl N 0 0 r -I 0 o O 0 0 0 0 0 0 0 N 0 CO lO C7 r:4 C7W waw inEnpaIII -R.,w-.-1— 0 0 d� N 0 0 .41 0 0 0 0 0 0 N N 0 0 0 0 Lr) 0 0 O 0 m 0 0 N FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 10/9/20085 7981 T-MOBILE\CALCULATIONS\HYDRAULIC CALC'S\T-MOBILE.SDF JOB TITLE: T -Moble WATER SUPPLY CURVE 132+ \ I \ I \ I \ 120+ \ I \ I \ I \ 108+ \ I \ I \ I \ P 96+ \ R 1 \ E I \ S X \ S 84+ \ U I \ R 1 \ E I \ 72+ \ ( I \ P 1 \ S I \ 160+ \ ) I I I \ \ \ 48+ \ I \ \ 1 \ 36+ \ \ \ \ 24+ LEGEND \ "* <-20.0 psi @ 10900 gpm 1 X = Required Water Supply " Flow Test Point 87.00 psi @ 939.5 gpm " 12+ " 0 = Available Water Supply 138.71 psi @ 939.5 gpm II II II 0++-+- +- + + + + + + + 32004800 6400 8000 9600 11200 12800 14400 16000 FLOW (GPM) FI E ALARM SYSTEM ADDIT TUKWILA, WASHINGTON T NUM RE S E ET TITLE --n1 SYST =M I \ FO MATT O FA -02 TYDICAL WIRI\G A\D vIOUNTING DETAILS 93 SYST =M CALCULATIONS AND SIN G LE LINE DIAGRAM n4 FIRE AL. M SYSTE vi PLAN - WithoutComments 0 As Noted In Red O Per The Attached Letter SHEET INDEX These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which cio not authorize violations of adopted standards and ordinances The responsibility for the adequacy of design ,-esfs totally with the designer. Additions, deletions i revisions to these drawings after this date will void this:. cceptance and will require a resubmittal of r`vised drawings for subsequent approval. Final acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 11- By: s� l TUKWILA FIRE DEPAR ih TFf fl �-=,a_--2 ;� O - and . ,..,....... Com._ v't,<�I 7� ��01 t.iifs i iF e r 6 9d it BL',Oa id exact 2d/� r. ss for shut- t�u`Ji 1.:1,7 , � .so in or restoration approval. IR- SCHED UL A\ COI\ DUIT FILL CHA SYMBOL DESCRIPTION WIRE DESIGNATION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C D P \, Vr STROBE SYNC DATA LINE -ADDRESSABLE LOOP DEVICE POWER - 24VDC STROBE CIRCUIT- FEED STROBE CIRCUIT - RETURN SPEAKER CIRCUIT - FEED SPEAKER CIRCUIT - RETURN REMOTE INDICATION LIGHT TWISTED PAIR WITH SHIELD TWISTED PAIR WITH SHIELD TWO TWISTED PAIR W/ SHIELD TWISTED PAIR W/ SHIELD TWISTED PAIR TWISTED PAIR TWO #14 #16 #16 #14 #14 #14 #14 #18 FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR FPL/FPLR RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS TWO TWO TWO ;ONDUCTOR VOLTS WIRE SIZE TYPE DIMENSIONS AREA 600V 600V 300V #12 AWG #14 AWG #18 AWG THHN/THWN THHN/THWN TWISTED FPL TW CABLE .244 0.D. .0467 .210 0.D. .0346 .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1 /2" 3/4" 1-1/8" 1-1/2" 2" .12 SQUARE INCH .21 SQUARE INCH .34 SQUARE INCH .60 SQUARE INCH .82 SQUARE INCH 1.34 SQUARE INCH IGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLE_ BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORI-Y HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE FERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NEPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS LASING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSENBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 F-) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY 1 15 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 3 FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S BOX CEILING 12 y FIRE ALARM STROBE 4 3 3 ZR -MC -CW SIEMENS 4S BOX CEILING HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD ®D DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N /A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND 00 Z. V) co Cr RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION J SHOP DRAWINGS DATE N. 2aaa<a UNIQLO SPACE #718 NORDSTROM 3 LEVELS ;71,27s maces PAT-UVrnc JCPenney •S 1 � i a1 F_Rt_ 1 • v4 SEARS SITE PLAN PAID 04) P^/ 13 2017 RA LA FIRE co Owa) T 0) oD5z �0 cc U� w ~� 0D LC cm- . O O pi, 0) /SCALE: NOT TO SCALE Z 0 0 z DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 / 15/ 17 V\ n JOB NUMBER: 26915-1) BACKROUND PLAN PROVIDED BY: SHEET FA -0 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved \ 01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDI11ONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-601Z DEDICATED EMERGENCY TUBE OUTLET SAMPLING TUBE INLET— SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE FOR ADDITIONAL SPECF:C'trONS sFE PRODUCT DOCIa'E'1TA11 I. 'CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL �+ OR PPEVIOUN ADDRESSABLE DEVICE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE alta! 0 GRD N L PAD -3 0 00 INPUT UPUI TROUBLE NAC1 NA.C2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 CISa [Mar 3.6k EOL 0 0 (-) (+) 2 NAC 3 CIRCUIT NAC 2 CIRCUIT NAC 4 CIRCUIT CEILIN TILE HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (-) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE o (+) FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) 1 0 0 SUPERVISED SWITCH ------- GROUND-13 - -- GROUND-13 In 0 0 HTRI-R OSTATUS LED Co 0 N.O. 0 COM 0 N 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. MUSIC 0 HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL LAC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4.OA @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERATURE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR 111 NEXT DEVICE OR END ❑F LINE DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE —) FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > REAR VIEW > TO NEXT 1 1 ADDRESSABLE DEVICE (+) SMOKE DETECTOR WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE HFP-71 TB1 0000®00 00 NO COM 2 NC EOLR v v V 470 0 00 TO FAN SHUTDOWN r7/ TO NEXT ADDRESSABLE DEVICE 0 00 B HTRI-R 0 NO ® COM B NC ® 0 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT O O O O • TO NEXT DEVICE -CADDY BAR SMOKE DETECTOR — -SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved IrZa ft4 a 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: SWITCH + — INPUT LED TSM -1 0 00 TO FAN SHUTDOWN r7/ TO NEXT ADDRESSABLE DEVICE 0 00 B HTRI-R 0 NO ® COM B NC ® 0 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT O O O O • TO NEXT DEVICE -CADDY BAR SMOKE DETECTOR — -SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved IrZa ft4 a 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE N Ln 2 aaaa< J w 0 cos �� 4:k co z Wco 2 OUB �— ,f)° --z O � a JIG Q z (1)W C/) 2 z' .1 cc w U Lu D2'5 CCOD LL- WH- O CO N U �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:1 1 / 15/ 17 BACKROUND PLAN PROVIDED BY: \ OB NUMBER:26915-1} r SHEET \ FA -02 i Q m 0 O W L.L O_- --) Y FIRE ALARM BOOSTER Project: UNIQLO - WSCM T.I. Panel: NEW PAD -3 REMOTE Date: November 15, 2017 Module/Device POWER BOOSTER Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 3425 Total(A)= 15 Total(B)= 3565 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 3565 Total current ratings converted to amperes (line D x .001) 0.015 3.565 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.2969645 Add lines G and I Total Standby and Alarm AH 0.6569645 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.7883574 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: UNIQLO - WSCMT T.I. Panel: NEW PAD -3 REMOTE BOOSTER POWER SUPPLY Date: November 15, 2017 Wire Resistance 2.58 CURRENT TOTAL= 3425.00 4 2 DEVICES ZH-MC-CW @15cd ZH-MC-CW @3Ocd ZH-MC-CW @75cd ZH-MC-CW @95cd ZR -MC -W @15cd ZR -MC -CW @15cd 9 87 131 222 292 64 69 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 348 393 0 0 0 138 879= 14 2 8 DEVICES ZH-MC-CW @15cd 71 -MC -CW @30cd al -MC -CW @75cd 71 -MC -CW @95cd ZR -MC -W @l5cd ZR -MC -CW @15cd 10 87 131 222 292 640_ TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E ) EOL Voltage 0 262 0 0 0 552 814 14 226 233 22.97 (WL*2)*.(R/ft) (Total Cct Load) (E= I * R) 24-E) 23.02 (WL*2)*(R/ft) (Total Cct Load) (E=1*R) 24-E) 879 1.17 0.88 1.03 22.97 814 1.20 0.81 0.98 23.02 6 2 DEVICES ZH-MC-CW @15cd al -MC -CW @30cd ZH-MC-CW @75cd ZH-MC-CW @95cd ZR -MC -W @15cd ZR -MC -CW @75cd 8 131 222 292 64 200 TOTAL mA= 1732. 14 0 1332 400 Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E ) EOL Voltage 246 21.80 (WL*2)*(R/ft) (Total Cct Load) (E=1*R) 24-E) 1732 1.27 1:73 2.20 21.80 CALCULATIONS FACP `ADD: Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 FDBZ492-HR 3 0.0635 0.0635 0.064 0.192 HTRI MODULE 4 0.009600 0.0096 0.021 0.084 0.0731 Amps 0.276 Amps 120VAC DEDICATED ( BY OTHERS) 3S S3-1 S3-2 S3-3 S3-4 75Cd 75Cd 75Cd 75Cd S3-5 S3-6 75Cd 75Cd S2-1 S2-2 S2-3 S2-4 30Cd 30Cd 15Cd • 15Cd S2-5 15Cd S3-7 75Cd S2-6 15Cd S3-8 75Cd EOL S3 S2-7 15Cd S2-8 15Cd J EXISTING TENANT J -BOX D S1-1 S1-2 S1-3 S1-4 30Cd 30Cd 15Cd 15Cd D,I HT -R 21 0 11-.7§F-11 D S1-5 S1-6 S1-7 15Cd 15Cd 15Cd SINGLE LINE DIAGRAM S1-8 15Cd S1-9 30Cd S2-9 15Cd EOL S1 S2-10 15Cd EOL S2 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved a V) co 0\ 743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE cN 10 co 1` zwo H<o) o 5z -� Wcco ¢z aw W D2" OD o co N SCALE: NOT cc 0 0 W z J W J 0 z o z 0 CJ) Cr) TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:1 1 / 15/ 17 BACKROUND PLAN PROVIDED BY: \OB NUMBER:26915-1} 1 SHEET FA -03 COL •.. 13 d 3 • :I E • S1-7 15Cd , ' I I • •—, • ; I\ / .11 S1i6 PD e—I HT -R TSM „lS ilil ....1! .., /-----f :1 ..i .1: ,-:, - .... -i ----- S--- --.1 --: S1-9 3OCd EOL S1 TO EXISTING TENANT JUNCTION BOX EMS 1 E S1-2 30Cd T. 43 X 4 S1-1 3QCd ;1- E3 / 7/ \„,‘•••• 104 CASE; \-VRAT-.) 2-8 " X 241 . . • i! • : I E --- • ! z„- „ :• 0' LJ E EE'f' Z S3-2 - 75Cd IGH D HT -R I TSM _I 11IGH..,___ S2-1- - • 30Cd 1 1 X •: ; I 1:5'LS11 111Cd 16Cal • HI S3-1 1 TSM .„1 -6 16Cd S 51;;14 2C -8d if= !11, $2-9 ;•7„. 15Cd ;• I1 , 1 HIGH HIGH I 75Cd HIGH HIGH C7 Oli\ FLAG NOTES: HELD LOCATE RELAY MODULE_FOR BACKGROUND MUSIC INTERFACE. COL, DUCT DETECTOR, RELAY MODULE FOR FAN HUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL IAND FIRE ALARM CONTRACTORS. FIELD LOCATE SIEMENS PAD -3 BOOSTER !OWER SUPPLY FOR STROBE POWER. AC ¶OWER BY EC FROM DEDICATED, LOCKED OUT ?OA, 110VAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. M • S3-3 75Cd 12_ (---47-- Lecer IX =1 X L -P-'•0_•.--•31- ) IILLL IlL 11! I / I S3-4 75Cd :1 I =1E' (1-•:-‘1 HL S3-6 75Cd 61 11 S3-5 75Cd FIRE ALARM SYSTEM PLAN S3-7 75Cd „ •-• I I•• 7/ s3-8 75Cd, i ., , • 1,7?. - • • y EOL S3 • - • i ,'"-- - -COL • . ..• -- • —COL = . , i;•; .1 : • i • I : I • „ : Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 7/-' • 1 I 11,111I1 z 1'0 co 743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE N Lt) 2 <<<<< L1J03 Z w OD 0 0 4:1; FIE < 0 ma- Z (i) 0 — 0 0 ;c >6. w z cc cn = (f) Z w < w w< cc cm 00 ‘CALE: 3/1 6"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1/15/17 BACKROUND PLAN PROVIDED BY: .JOB NUMBER:26915-1i SHEET ( FA -04 ..) SHEET NUMBED FILE COPY SHEET TITLE SHEET INDEX T MOBLE FIRE ALARM SYSTEM TUKWILA, WASHINGTON FA -01 SYSTEM I\FORMATION FA -02 TYPICAL DETAILS - WIRING A \D MOUNTING FA -03 FIRE ALAS M SYSTE \A FLOICH PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), MISER, SITE PLA\ 1 Without Comments n As Noted In Red (1 Per The Attached Letter t hese plans have h.- ^r r: j �, T!_.=, Tulcilita Fire Prevention Bureau tor c c :..:. standard omissio^y h SttanUE., ci r adequacy o. r i !this resubmittal or 1, Final accap.r. ncC ..: _ <''j' l ' i relri test and inspection b` rile Tukwila Fife Prevention Bureau. Date: /0- 3- 018 731 ...]i -i- nt city adopted 'or the r r. ..::ngs atter nt Epproval. By: A1/) sI FUKWILA FIRE DEPARTM .N8 Please call: 575-4407 and give this job No. O $ - F- 9-7. and exact address for shut. clown or restoration anoroval. 1 A NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testinrj, r41;7 Because of increased demand our inspectors' schedules ire booked 3-7 days ahead. Therefore, you will need to call 206-575.1407 to schedule your inspections a minimum of 48 hours in advance of the date you want an insceclion. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TW❑ 4414 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO 1#16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR \d/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR 1414 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COIVPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT ANC DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) VIHERE THE CABLE IS INSTALLED QUANTITY 2 1 6 1 EX SYMBOL DESCRIPTION SYMBOLS LEGEND MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD a DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE D DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -CW SIEMENS SET -MC -W SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM SET -HMC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. L FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING 111 Q c FIRE ALARM STROBE (WALL MOUNT) FIRE ALARM SPEAKER (CEILING MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. Y B WP FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD ❑M MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD JUNCTI❑N BOX F,B.❑. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.❑. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.D.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAID OCT - 7 2006 Tukwila Fire 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 LLJ Ct w LLI -J UJ REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 00 0 I` 0 0 z aaCCC 00 co -11:39 W mZ W c mmmi (5f- 0 O Uc W co �CALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 10/07/08 Ti9n BACKROUND PLAN PROVIDED BY: JOB NUMBER:54554 / \r)6( SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC 0 DUCT DETECTOR LOCATION END OF LINE DEVICE(3,6K 1/4W) SUPERVISED SWITCH GROUND 0 N) 0 0 HTRI—R OSTATUS LED 00 0 N.0 r- 0 0 COM N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. o O �J TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL KALE (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING TUBE INLET SAMPLING—\ TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE LI -AC POWER SOURCE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE Sim STOP IF LAST DEVICE(+)- FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE (-) END OF LINE DEVICE (3.6K 1/4W) RELAY CONTACTS (4.OA @ 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 mA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0,02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. 0 + TB1 5 0 0 0 0 123456 HCP TB2 es.�+g00 6 5 4 3 2 1 0 0 / / SUPERVISED/ SWITCH GROUND / NOTE: 0 © HTRI—D STATUS LED 0 NOT USED 0 1 0 FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL `ABEL SCIE(FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC 0 000 0 PAD -3 0 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 000 0 24K n + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE tu END OF LINE DEVICE 3.6K 1/4W) - UPERVISED SWITCH 2 —Z NAC -4 NAC -3 NAC -2 NAC -1 1' FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE E DEVICE LOOP NOT USED REMOTE DEVICE LOOP .�. 0- 0 0 0— FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS iw EOL TEM -1 0 0 • • • e TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE:NONE FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) 10 () STROBE SPEAKER 0 0 EARTH GROUND -304+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE 6) STROBE-) (+) (-) STROBE SPEAKER SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY R --''�77 _✓Y 0 0 : 4S DEEP BOX IN/ 1-1/2" I EXTENSION RING ((SPEAKER STROBE) 4S BOX I (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER�T�IN TEMPERATU +32' F (0' C) TO 100' F (33E8' C) HUMIDITY: 9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —� DEVICE IS USTED FOR AIR VOLOaTY APPLICATIONS OF 300-4000 FTA4IN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR r D8-11 STANDARD SMOKE DETECTOR BASE rFROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE 1 DATA IN (-) > DATA IN(+)> HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID —\ CEILING SPEAKER SUPPORT TILE BRIDGE ,-- 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTI❑N BOX MOUNTED ON CEILING FLEX \ JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT %L1 O O I TO NEXT DEVICE / / / / 0 0 CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SUSPENDED ILLUMINATED CEILING SCALE:NONE DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z DESCRIPTION SHOP DRAWINGS DATE 10/07/08 2 CCCCa co co '- J 07 W �z WW1 m `n z z O ccvco �— �co O g LL co 1— J �CALE: 1 /8"=1' z z 0 0 z 0 z J 0_ DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:10/07/08 BACKROUND PLAN PROVIDED BY: \0B NUMBER:54554 SHEET FA -02 EOL—S1 20.06V FACP EX D,I 2I 15 C 2S,2vx c) -2S, 30 C 2S,2V 2S,2V i1 bl L 30 C 30 C NORTH T MOBLE WESTFIELD SOUTHCENTER MALL SCALE 118"=1' FLAG I\ OTES: S: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATI❑N SUBMITTAL FOR L❑CATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACT❑R, WIRED BY ELECTRICAL CONTRACTOR, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESION SYSTEM, FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 2OA, 110 VAC BRANCH CIRCUIT, PLANS NOT APPROVED DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z DESCRIPTION SHOP DRAWINGS DATE 10/07/08 2 CCCCC CO co —10'; O) wre re0 LA- W co -1 zz OCCvu, E- w o �g Li- co t`_ W LL 6ALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:10/07/08 BACKROUND PLAN PROVIDED BY: \0B NUMBER:54554 C SHEET FA -031 D 11135 1470 (r) 0 CO <0 FiLd 1140 TOUT 1111111111111m scum 14601 ILLUMINATIONS 114751 STAEs-:BUCI<S NORTH 1 111551 11160 11440 • ry c,r) .J1 _J 0 KIDS FOOTLOCKER 1200 11430 111 OAP BODY 12101 SYSTEM CALCULATIONS -r 4.,f--)! _J LLI -J 114101 ELTC7RICA.L RM 1851 1490 . . II RECYCLING II STORAGE 11495 1 1 RISER ROW LOADING DOCK GUESS WESTFIELD SOUTHCENTER WALL CHEESECAKE FACTORY R3 LY uJ 0 0 0 0 ›- rTh 123. (r c 0 1 v251 SCALE 1132'1=1' 30 C 30 C 30 C 15 C 15 15 15 EOL -S1 FA -$31:1X FACP EX 4» DJ 21 IFORNIA MAC GRILL RL BATTERY SIZING CALCULATION Notification Appliance Circuit Detail I PROJECT: IWESTFIELD SOUTHCENTER MALL TENANT IT MOBLE !Wire Resistance 1.62 Date: 1 October 7, 2008 1 CURRENT TOTAL= 550 1 IS1 CIRCUIT: ' i 1' • , a QTY Device Type 'Alarm Current Alarm Total Wre Size Wire Length a Voltage at EOL Circuit Total a 3 3 0 0 0 !,SET -MC @15CD I SET -MC @30CD 1SET-MC @75CD 1SET-MC ©110CD 1SET-HMC-C©115CD 0 LSET-HMC-C©177CD 0 !SET -HMC @135CD 0 SET -HMC ©185CD 641 192 Total Wire Resistance ( R ) 981 294 (WL*2 )* (R/ft) 0.62 1751 0 Total Device Load, Amps (1) , 0.55 _,.......__ ....,_ _..._ 233 0 , (Total Cct Load) 3181 0 a Voltage Drop ( E ) 0.34 4451 0 i , (E= I * R) 3181 0. i EOL Voltage j 20.06 4451 0 j (20.4 - E) F 1 IZ-MC©15CD 64 64 0 Z-MC©30CD 981 0ISET-MC-CW©110CD 1 233 DEV10ES=17 TOTAL mA=I 5801 12 191 20.059638 I Notification ADDliance Circuit Detail !PROJECT: 'WESTFIELD SOUTHCENTER MALL 1 1 TERNANIT MOBLE Date: 1 October 7, 2008 CIRCUIT:SPEAKER CIRCUIT Wire Resistance 2.58 CURRENT TOTAL=110.8 Device Type Alarm Current Alarm Total Wire SiZB Wire Length Voltage at EOL 1 Circuit Total 6 170.7V1/8 1 1.8 10.8 0 0 01 0 0 01 0 0 0 Oi 0 01 0 0 0 0 0! 0 0 1. 0 0 0 01 1 0 DEVICES= 1 TOTAL m - 10.8 0 14 Total Wire _Resistance OR ) 0.99 ( WL* 2 )* (Rift) 1 Total Device Load, Amps (1) 0.01 (Total Cct Load) Voltage Drop ( E ) L (E= I * R) EOL Voltage (20.4 - E) 20.38935595 co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 z 0 c7) 5 uJ uJ (f) LU LLI REV. BY: T MOBLE CRAZY 8 FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS LLI 1 5/15/08 I- Current Load: Standby: Alarm: CI Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 AD2-P 1 0.0635 0.0635 0.064 0.064 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R 2 0.009600 0.0096 0.021 0.042 SET -MC @15CD 0.064 HTRI-D 0.001600 0.0035 SET -MC @30CD 0.098 ICP -B6 0.005 SET -MC @75CD 4 0.175 0.700 SET -MC @110CD 0.233 SET-HMC-C@115CD 0.318 SET-HMC-C@135CD 0.318 0.0731 Amps 0.106 Amps SET-HMC-C@185CD 0.445 ZR -MC @15CD 1 0.064 0.064 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 0.098 HCP 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.03 Amps 0.794 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.794 Amps For 5 Minutes= 0.067 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 0.983 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 0.983 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION Notification Appliance Circuit Detail I PROJECT: IWESTFIELD SOUTHCENTER MALL TENANT IT MOBLE !Wire Resistance 1.62 Date: 1 October 7, 2008 1 CURRENT TOTAL= 550 1 IS1 CIRCUIT: ' i 1' • , a QTY Device Type 'Alarm Current Alarm Total Wre Size Wire Length a Voltage at EOL Circuit Total a 3 3 0 0 0 !,SET -MC @15CD I SET -MC @30CD 1SET-MC @75CD 1SET-MC ©110CD 1SET-HMC-C©115CD 0 LSET-HMC-C©177CD 0 !SET -HMC @135CD 0 SET -HMC ©185CD 641 192 Total Wire Resistance ( R ) 981 294 (WL*2 )* (R/ft) 0.62 1751 0 Total Device Load, Amps (1) , 0.55 _,.......__ ....,_ _..._ 233 0 , (Total Cct Load) 3181 0 a Voltage Drop ( E ) 0.34 4451 0 i , (E= I * R) 3181 0. i EOL Voltage j 20.06 4451 0 j (20.4 - E) F 1 IZ-MC©15CD 64 64 0 Z-MC©30CD 981 0ISET-MC-CW©110CD 1 233 DEV10ES=17 TOTAL mA=I 5801 12 191 20.059638 I Notification ADDliance Circuit Detail !PROJECT: 'WESTFIELD SOUTHCENTER MALL 1 1 TERNANIT MOBLE Date: 1 October 7, 2008 CIRCUIT:SPEAKER CIRCUIT Wire Resistance 2.58 CURRENT TOTAL=110.8 Device Type Alarm Current Alarm Total Wire SiZB Wire Length Voltage at EOL 1 Circuit Total 6 170.7V1/8 1 1.8 10.8 0 0 01 0 0 01 0 0 0 Oi 0 01 0 0 0 0 0! 0 0 1. 0 0 0 01 1 0 DEVICES= 1 TOTAL m - 10.8 0 14 Total Wire _Resistance OR ) 0.99 ( WL* 2 )* (Rift) 1 Total Device Load, Amps (1) 0.01 (Total Cct Load) Voltage Drop ( E ) L (E= I * R) EOL Voltage (20.4 - E) 20.38935595 co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 z 0 c7) 5 uJ uJ (f) LU LLI REV. BY: Z DESCRIPTION SHOP DRAWINGS LLI 1 5/15/08 I- <1( CI 2 <<<<< ‘C' ALE: 1 /8"=1' DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE: 10/07/08 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved .JOB NUMBER:54554 i )f' SHEET FA -04 E f) /6" Reliable Model "G" Riser Check Valve 1 0" Victaulic #750 /Butterfly Valve n WILKINS 10" 350 DAG n Vertical Backflow Preventer [X\ 10" Victaulic #750 Butterfly Valve 1 0" Flange 4. @ I '-2" AFF \ FF @ 0'-0" ..0._ 10" D.I. \ �L @ -4'-0"± S stem T4 Riser Assembl Detail N.T.S. Source T Io 7, UP 10" x 9'-6"7 -61 8H /4.@2'-O"AFF / t- c o;: DN 6" x 1 2'-6' 3L8" 1 2'-0" FOW 4" x I I'- I 0"±6" 2'-0" 5'-0" FOW 1 r FOW @ 1 4'-6" AFF 4.08 R �" 3'-8" € OB o 0 L 4" x 85'-0":_t6" 4. @ 14'-6" AFF 9'-9Y4' TOLCO FIG. 25 SURGE RESTRAINER TYPE 1 - FOR I" AND 1/4" PIPE AND HANGER TYPE 2 - FOR Iy2' AND 2" PIPE AND HANGER TOLCO FIG. 25 15 DESIGNED TO BE USED ONLY WITH TOLCO BAND HANGERS FIG. 200 AND 2NFPA TO RESTRAIN THE UPWARD MOVEMENT OF PIPE AS IT OCCURS DURING SPRINKLER HEAD ACTIVATION OR SEISMIC ACTIVITY SYMBOL = FIGURE 25 SURGE RESTRAINER FOR STEEL OR CPVC PLASTIC PIPE 8'-2Y4" UL HILTI KWIK BOLT 3 ANCHOR ICC REPORT #ESR -1385 MIN. OF 3,000 PSI CONCRETE MIN. 3 1/4" CONCRETE OVER MAX. 3" METAL DECK 3/8" ANCHOR W/20# TORQUE: TENSION -7395#, SHEAR=750#* 1/2" ANCHOR W/40# TORQUE: TENSION=440#, SHEAR=750#* •SHEAR LOADS HAVE BEEN REDUCED BY 20% FOR SHEAR THRU THREADS 1/4" MIN ROD COUPLING THREADED ROD PIPE ROD BOLT IMBED SIZE DIA. LGTH DEPTH I" 3/8" 3 3/4" 2 1/4" 1 1/4" 3/8" 3 3/4" 2 1/4" 1 1/2" 3/8" 3 3/4" 2 1/4" 2" 3/8" 3 3/4' 2 1/4" 2 1/2" 3/8" 3 3/4' 2 1/4" 3" 3/8" 3 3/4' 2 1/4" 4' 3/8° 3 3/4' 2 1/4" 6" 1/2" 3 3/4' 2 1/4" 8" 1/2" 3 3/4" 2 1/4" HILTI FIG. LH OR TOLCO FIG. 200 HANGER RING UL 04/2007 COSCO STANDARD HANGER 13 MDL 0 cn CV 0 i" - B_ 4'- 1.1" FOW 0 7_1" N .FOA FOW O 0-6 0 I 00 �LXC 14'-i Iy2" . \ \ L\; S5 u J B ice; 1 k IFOW O m .N 0 w 4'- I I%2" . 2'-!0" ti Si FOW i� CD 1' mommf Now. 1•00 0-41¢ II ;l t . /•' _ 0=10 t_ 0100.0 • .-, 0 .o— • • • FOS m3 FOW FOW '.l f• i• : t; 1,1 rriV • I CONSTRUCTION NOTES: 1) PIPE: THREADED: STEEL, SCH 40, BLACK, IMPORT. GROOVED: STEEL, SCH 10, BLACK, IMPORT. 2) FITTINGS: GROOVED: STAR STANDARD - ORANGE PAINT FINISH THREADED: STAR D.I. 3) GROOVED COUPLINGS: STAR RIGID C-4 UNLESS MARKED WITH AN "P', WHICH ARE TO BE STAR FLEXIBLE C-3 LW - ORANGE PAINT FINISH 4) HANGER MATERIAL: ALL HANGER MATERIAL IS TO BE FINISHED BLACK OR STANDARD 0 GENERAL NOTES: ) I) SYSTEMS ARE DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF N.F.P.A. 13-2007 ED., THE CONTRACT DOCUMENTS, AND THE CITY OF TUKWILA. CRITERIA: OCCUPANCY: ORDINARY HAZARD GROUP II. ORDINARY HAZARD GROUP II SPRINKLER SPACING: 130 ft2 MAX. 2) COSCO'S POINT OF CONNECTION IS AT EXISTING SYSTEM AS SHOWN. 3) ALL PAINTING OR PREP OF FIRE SPRINKLER PIPING ( IF REQ.. ) TO BE DONE BY OTHER. 4) ALL WIRING OF SYSTEM DEVICES IS BY OTHER. 5) OWNER IS RESPONSIBLE TO ASSURE THAT THE STRUCTURE, AS IT IS SHOWN ON THE CONTRACT DRAWINGS, CAN ADEQUATELY SUPPORT THE FIRE SPRINKLER PIPING. NO AUXILIARY DEVICES OR ATTACHMENTS SHALL BE PROVIDED BY COSCO TO SUPPLEMENT THE STRUCTURE. 6) OWNER IS RESPONSIBLE TO PROVIDE ADEQUATE HEAT TO MAINTAIN 40°F. MINIMUM AT ALL TIMES. 7) OWNER IS RESPONSIBLE TO ARRANGE FOR THE PERIODIC INSPECTION, TESTING, AND MAINTENANCE OF THESE FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF N.F.P.A. 25-2002 ED., BY QUALIFIED PERSONNEL COMMENCING AFTER WARRANTY PERIOD HAS EXPIRED. THE FIRM THAT DESIGNED AND INSTALLED THE SY5TEM(5) IS BEST QUALIFIED TO PROVIDE THE ONGOING LONG TERM TESTING, MAINTENANCE, AND SERVICING. 8) COSCO TAKES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE OR CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIED OR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO FIRE PROTECTION. 1 SEE PLAN FOR LENGTH REMOVE EXISTING SPRIG --"� INSTALL NEW 1x0-6 NIPPLE ADJUSTABLE HUB MAX. 2'-O" MOUNTING BRACKET EXISTING BRANCH LINE MAX 2'-0" "FLEXHEAD" FLEXIBLE DROP CORRUGATED STAINLESS STEEL —' BRAIDED HOSE (4'-O") CEILING ADJUSTABLE HUB MOUNTING BRACKET 1" aSEE PLAN FOR LENGTH CT, SEE PLAN FOR LENGTH 1 w tY i O LL _"FLEXHEAD" FLEXIBLE DROP CORRUGATED STAINLESS STEEL BRAIDED HOSE (4'-O") CEILING REMOVE EXISTING SPRIG INSTALL NEW 1x0-6 NIPPLE EXISTING BRANCH LINE 1 ADJUSTABLE HUB MOUNTING BRACKET B TYPICAL ARMOVER TO NEW SPRINKLER HEAD N.T.S. T—Mobile: SCALE: Y4" = 1 '-0" t t CCE TED Without Comments As Noted In Red Per The Attached Letter 1 nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions these drawings atter this date will void this acceptance :-And will require a resubmittal of revised drawings for subsequent approval. Final -acceptance is subject to field test and inspection IA The Tukwila/Vv"iFire Prevention Bureau. Date: /0 9-02 By: Jt IMPORTANT NOTICE Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. TUKW1LA FIRE DEPARTMEhi't Please call: 575.4407, and give this job No. og-S-(1-761 and exact address for shuts down or restoration aoi roval, NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic test approval. FILE COPY r, -rt Of SPRINKLER HEAD LEGEND : SYMBOL S/N ORIFICE NPT K -FACT. HEAD FINISH PLATE FINISH TEMP. (VAN. Reliable Model FI FR Recessed SSP 1/2' 1/2' 5.6 Chrome Chrome 155° 6 Reliable Model G4A Concealed SSP 1/2' 1/2' 5.6 Bronze White 155° 17 APPROVALS BY: l TOTAL SPRINKLERS THIS SHEET 23 •00 00 00• *00000" "00000• I cosco Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS WASHINGTON OFFICE www.coscofire.com 10910 117TH Place N.E. Kirkland, Washington 98033 call (425) 827-9654 • fax (425) 827-7474 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE • ANCHORAGE License No: COSCOFP 110NM T -Mobile 718 Southcenter Mall, Suite # 1475 Tukwilla, Wa. 98188-2823 e.'"D-1#PAID OCT - 9 2008 Tukwila Fire 42(12g 1/4; — CONTRACT WITH: Hawk Building P.O. Box 2318 Woodinville, Wa. 98072 Contact: Ryan Adkins (425) 273-1583 DRAWING TTTLE T -Mobile: Fire Sprinkler Piping Plan GATE : October, 2008 SCALE : As Noted DRAWN BY : Justin Johnson Mss - 798 1 SHEET NO. FP 1 of 1