Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 728 SOUTHCENTER MALL - EMERALD CITY SMOOTHIE - PERMITS AND PLANS
728 SOUTHCENTER MALL ASSOCIATED PERMITS 11-F-281 11-F-241 08-F-169 11-S-204 08-S-096 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: -T" ? g � r 1A/10.\\ Suite Number: No Floor: Tenant Name: rmy -31)1(\ riS New Tenant? Yes ❑ - No k'�\Property Owner's Name: \- A( �1 1� �� Y"19 C v Mailing Address: 1 \bC).`w \snki-e__ eF:s1\43„ /1\ , Los ,cieae s , Cly g CO2S City State Zip CONTACT PERSON -if there are questions about the submittal. Name: c S`CQ 010I VISO() 1-712.11-87-7(o(6? Day Telephone: Company Name: CV, 1 w e T"1 rtC,C+k Cir), 1V1C_, Mailing Address: Box ` G--\ 1 1' 1 l ee z.1 q w $'7 XJ E-mail Address:de SS\ C) C rtkoin • Cb Yfl City Fax Number: Liam ggitg cA Valuation of Project (contractor's bid price): $ l ,CC) Scope of Work (please provide detailed information): Mak_ C -V > -� \rte \n-611(1� PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING N�ERR OR AUT D AGENT: Signature: .aa l CQ Print Name: 3PSCIVGit71 YIDf Plan Permit App.doc Date: RkSkA Day Telephone: 1-12— $1-1piCl9 5/14/10 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 4AZTZ$ SINAJAI e2. 9{ r C / Suite Number: Floor: Tenant Name: 310.1J�`o(v4:6- Property Owner's Name: 7 i- � i& (Kcal. Mailing Address: New Tenant? - Yes ❑ - No CONTACT PERSON -if there are questions about the submittal. Name: cs. ck,e_ City State Zip Day Telephone: C o6) 3 S I Z6 & . Company Name: Cs-� d-, et" C tZC'A"r `-)"v 0tict Mailing Address: t Ttt Of' l- S t 3 City / State Zip E-mail Address: r 'C� u �,0`"` �-'-+ ` Fax Number: C`u%6� 3 4 6t t7 Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Ftp vh s PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested m writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: (0/21/ I ) Print Name: k2- 5` L Plan Permit App.doc Day Telephone: C2)Y /2-6 g 5/14/10 TFD FP Form 8 MIN SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: WA Site Address: 7 23 SL M intik Suite Number: 1 ti SO Floor: Tenant Name: .J i vv r .3.:1101 h S New Tenant? ❑ - Yes Z1- No Property Owner's Name: `tib S 4- old Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: �0.e.c) e_. F Kik-t Company Name: U.,rdci, Se. CAA.r-1 y Mailing Address: i i? t 9 � S O i Sect- L' , LA 'TS 1 34 E-mail Address: f kic1City State Zip � 3u t a'^Se 2 t.v i C.it+► Fax Number: Cac�4a7 3Z11c{ Q'Z& Day Telephone: C2 )3S9 I 2.15 Valuation of Project (contractor's bid price): $ 3, ) 00 i Scope of Work (please provide detailed information): Part i �n 2 ee.da_.) 0.".d 2 5 wvo vv.._ a (ca -c", s.,)c key., ckeJe c {'o r S - PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: 1 Print Name:pt� L� Plan Permit App.doc Date: 2142.g/ 11 Day Telephone: t 2.96) �jS 1 7 GE 5/14/10 TFD FP Form 8 • FILE COPY FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Emerald City Smoothie 728 Southcenter Mall Permit No.: 08-S-096 Date: April 1, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. All references are NFPA 13, 2007 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Jimmy John's 728 Southcenter Mall Permit No.: 11-S-204 Date: September 13, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. JIMMY JOHN'S NEW FIRE DAMPERS FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUN3ER SHEET TITLE FA -01 SYSTE \A INFOv1ATIO\ FA -02 CALCULATION, WRING DIAGRAV A\D SINGLE LINE DIAGRAM FA -03 FRE ALA M SYSTEM PLA SHEET INDEX Without Comments O As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date•L2,-1)9-14 By: W NOTICE A completed, signed, Tukwila Fire Depa[tment Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. TUKWILA FIRE DEPARTMENT Please call 205-575-4407 and give is Fire Permit No. and exact address for shut- down or restoration approval. =DULE A\D CONDUIT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NEPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY 2 2 EX EX EX EX EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT HTR -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING DUCT DETECTOR DEX AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR EX TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HTR -R INTERFACE MODULE HTRI-R Ex WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD DEX FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXTN FIRE ALARM EX STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A -N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N /A N/A N/A N/A SYMBOLS LEGEND \1 l NORDSTROM 3 LEVELS 171,275sf ES=R_SSO macys 4 LEVELS 250,4C7sf JIMMY JOHN'S 728 ,ne LEVELS vyivs 2 7, B IME i-- SIA:a�A<5 4 F°:,71.,,. ?clyY[ 'IF RAS 4:+5 IIME_AR Il 3EYER 4 COLD G CLErv, AK' S;.W^�AS', .-sae LE 1.5 w.cLErsoo<S YALE =1 NAS.':v1CN UTNE tar5 STAR3xS •Y ;^LE PAOCC SYY(F_AP ,CTNER;cco FIERQNC PASCCA B+SCM ❑ 'la 5 ,NM R.a w a P.AYTpM a R. [ SEARS 2eW raw.. ELL- ra-LELL MAL RESTIaRLINT 'ATO SITE PLAN PESTALVIT ATO �+�Stift IWS,LE !:'I. crier '_,PIRt 1. £A1c S E� 1 . REST'. ▪ JCPenney • 3 LEVELS 275,46ao f PAID DEC 28 2011 TUKWILA FIRE 03 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: CD M 0 DESCRIPTION SHOP DRAWINGS DATE N .2aaaaa C!) CC W 0 c T co 00 QWr W E - O) CC o ) J or W W () wQ C12IIICC z D co te `r I I _ Z 0 cc 0 )1- N �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:12/ 19/ 1 1 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 55361_1 �i FA -01 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET DATA ❑UT DATA IN C O 0 s 00 N/❑ c N/C 0 8 7 6 c DOWEI PA\EL 0 O H DAIVPE. DAV PES 120VAC FSD POWER TO 3E PROVIDED BY OTHE FIRE SMOKE DAMPER SHUT -DOWN WIRING DETAIL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERIIN TEMPERA RE: +32' F 0- C) TO 100 F 36 C) HUMIDITY: 0- 9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR �1 -> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR �- DB -11 STANDARD SMOKE DETECTOR BASE fDATA IN (-) �— DATA IN (+) > > TO NEXT ADDRESSABLE (+) DEVICE SMOKE DETECTOR WIRING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINS CEILING SUPPORT -00 0 0 IL T❑ NEXT DEVICE CADDY BAR SMOKE DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL TYPICAL WIRING AND MOUNTING DIAGRAMS TO NEAREST EXISTING SPEAKER CIRCUIT ( TO POWER SUPPLY TO NEAREST EXISTING DATA LOOP IN HALLWAY i$ Tfi; '�� si�lf DMG I f t f r Y DESCRIPTION SHOP DRAWINGS Current Load: 0) N Standby: Alarm: z<aaaa Device Type Qty Amps Total Amps Total HFP-11 2 0.0022 0.0022 ° 0.0023 0.005 AD2-P 1 0.0635 0.0635 0.064 0.064 H1R-R 4 0.009600 0.0096 . 0.021 0.084 0.0731 Amps 0.148 Amps V,V' CALCULATIONS S1-2 30cd V-2 EX s,s',v,v' FLAG NOTES: FIELD LOCATE RELAY MODULE WITHIN 3 FEET OF FIRE SMOKE DAMPER. 120VAC FIRE SMOKE DAMPER POWER TO BE PROVIDED BY OTHERS. FIELD LOCATE SMOKE DETECTOR WITH 5 FEET OF FIRE SMOKE DAMPER. s,V,V' s,V,V' V S,V,V' D EX S1-1 15cd 15cd V-1 S1-3 EOL EX EX EX S1 S1-4 S1-5 30cd 30cd V-3 V-4 D D,I IHT-RIEX 214 TSM EX SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE 0) N z<aaaa SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:12/19/1 1 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 55361 J SHEET FA -02 COOLER & FREEZER 103 (S) - TO POWER SUPPLY, (V,V) - TO NEAREST SPEAKER CIRCUIT ADJACENT & TENANT N.I.C. (D) - TO NEAREST DATA LOOP IN HALLWAY A \\\\\ SFD� _.__�).{,i R 1 DINING B 100 U 0 I¢ Z W +15'-6" B.O. ROO DECK PAINT PT - DINING A 100 L FREEZER 6' x 6' 1 HT -R REFRIG. 6' x 6' D I' I • \i\ D S,VV; \\\\\\\\\\\ \\ STORAGE 102 10'-6" 15cd EX S1-3 15cd • II 7 /I \i CLNG. TILE C-1 TSM KITCHEN/PREP 101 10'-6" CLNG. TILE C-1 7'-6" GYP. BD. SOFFIT PAINT PT -4 HT -R S1-5 30cd MALL - N.I.C. FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE WITHIN 3 FEET OF FIRE SMOKE DAMPER. 120VAC FIRE SMOKE DAMPER POWER TO BE PROVIDED BY OTHERS. FIELD LOCATE SMOKE DETECTOR WITH 5.FEET OF FIRE SMOKE DAMPER. Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 0) Z N I <<<<< W LL. SCALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:12/ 19/ 1 1 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 55361 SHEET f FA -03 SHEET NUMBED SHEET TITLE ? � Y s S t fi 1 fLJC31---LNT'!t f } FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON FA -01 SYSTEM I\ FO MATION FA -02 TYPICAL WRING A D MOUNTING DETAILS FA -03 SYSTEM CALCULATIO\S AND SINGLE LINE DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the ydequacy of design rests totally with the designer. Additions, deielons or revisions to these drawings after his date will void this acceptance and will require a resubmittal Of revised drawings for subsequent approval. final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Buri au. Date: By: W J I I TUKWILA FIRE DEPARTMEN Please call 206-575-4407 and give this ire Penni' No. Il- --(XL)1 and exact address for shut- down or restoration approval, RULE A NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. \D CONDUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLJFPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPUFPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPUFPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 4 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ®D DUCT DETECTOR AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HTR -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXTN FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND JIMMY JOHN'S' 728 mervyn's 2 LEVELS :5,__'sf 250.407sf h NORDSTROM 3 LEVEL S 171,275sf 'I+E RA,E *SE tl•f.UM 3lN_R 4 f:Clf) 0 LLDO,Sia<s C LICE A T^ C(4PT 12-".+APf :44 • JCPenney 3 LEVELS 276,•168 f ° 0. n P,AYTIX 1 PATO RESTAtPANT ATO RETAIL RESTAI WR ATO WIRE DESIGNATION GENERAL NOTES SITE PLAN 1.1 PAID OCT 21 2011 TUKWILA FIRE -2av 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 1 0/1 4/1 1 2<aaaa co d- T ; Z 00 O�� Z Q ..o J~ 0 LIU ›. tow¢ <HEw CC O� co 0 6ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/14/11 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved BACKROUND PLAN PROVIDED BY: 1.0B NUMBER: SHEET � FA -01 12OVAC-6 1Z DEDICATED EMERGETNCY l THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. PUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL FATE: FOR ODO M AL SPE0ff1CA110NS SEE PRODUCT DCCUBENTA110N. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FROM TO NEXT ADDRESSABLE C IP DEVICE STIF LAST DEVICE - FROM XLS comTRIIt. PANEL (1 OR PREVIOUS ADDRESSABLE DEVICE - 0 O 0 HTRI-R o NOTE: FSEEEE PACT DDOCUMEENl CATIONAL Os C -CABLE C -CABLE 00 0 PAD -3 00° INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1- 1 2+2- 2 NC C NO + - + - + - + - + - (-) (+) ee SPARE SPARE SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) D❑ NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. m 5 P1 m 0 0 PI PI 0 C (=)(-) (+)(+) 4 (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIED #18 FPLIFPIR RED (JACKET) *CONTACT RATQNC& 4.0A 0 125VAC 4.OA 0 30VOC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O a * 1 0 a 0 HTRI-R 0 r-7 1-6 c4 DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. _ l GROUND ��\ (+)> TO NEXT DEVICE OR O ❑n _tel 111 — i DMG I ❑ '�,�/, ,110( y + _ISI III 0 a O T°A. J - w� 7 7 r ' '€ ;1; Si;' 'I1;► +— Attetnt . AICIEFIIIIx :2 gf1 q I II ha2 I:1:1:1:111:1:1* 1:11:1:1 I CCI. PI v '09 41.11 X V _i— ��jt1• ill 4 0 114❑ p <a 'i :1 1/ '.� 7 !I o 0❑ (-) POWER SUPPLY & RELAY MODULE WIRING DETAIL FROM PRECEDING SPEAKER (+) (+) (-) STOP IF LAST DEVICE DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL STROBE SPEAKER •y _ 0 DMG ■ — _ , ,110( y + _ISI III 0 a O O J - w� 7 7 r ' '€ ;1; Si;' 'I1;► +— Attetnt . AICIEFIIIIx :2 gf1 q I II ha2 I:1:1:1:111:1:1* ,01.:- I:I I:I:I I I:1:1b PI v '09 41.11 O O — —7 ��jt1• ill 4 0 114❑ p <a 'i :1 1/ '.� CIRCUIT D❑ STROBE ❑DDI CIRCUIT =❑ STROBE 40❑ 1 1 O — DMG - _ — _ ❑ , ,110( y SHOP DRAWINGS _ISI III 0 u l� O 'E, (. -/wan O (J� S " T n+ 'I1;► +— Attetnt . 11B8H81198 �''-� . +- AtCOIF$N " • q ` y ,01.:- I:I I:I:I I I:1:1b PI v '09 41.11 Iti — ill 4 0 114❑ p <a 'i :1 (-) (-) OR FIRE ALARM CONTROL PANEL < (-) SPEAKER CIRCUIT (+) (+) Dnu STROBE SPEAKERISTROBE 1n0 01E1 ■10 — - DMG O❑f 10°01 I❑0 y SHOP DRAWINGS _ISI III 0 O 'E, (. -/wan 0 n+ +— Attetnt 11B8H81198 �''-� . q ` y = PI v '09 41.11 ill 4 IDD (-) STROBE (-) SPEAKER CIRCUIT SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS (+) (-) SPEAKER CIRCUIT 5 TO NEXT APPLIANCE S OR 24K (EOLR) TO NEXT SPEAKER S OR END OR LINE RESISTOR 24K (EOLR) NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER T1N TEMPERA RE: +32' F (0' C TO 100' F 3LT C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —' FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOaTY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR �— DB -11 / STANDARD SMOKE DETECTOR BASE (+) SMOKE DETECTOR WIRING DETAIL HARD LID CEILING > TO NEXT > ADDRESSABLE DEVICE SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSION N CEILING MOUNTED SPEAKER/STROBE X SPEAKER STROBE MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX \\` � ______547) -Jim JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT SMOKE/HEAT DETECTOR TO NEXT DEVICE CADDY BAR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved W ti FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 0 0 co T 00 O w 01) z 9°z _ `C O� OdC W �z ›- CI) w cc w w� CC ©F-- co N 1` z O 0 z c� z J U �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/ 14/ 1 1 BACKROUND PLAN PROVIDED BY: \0B NUMBER: SHEET FA -02 111 ' - I' JIMi. 0 0 DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: 10/14/11 2 <<<<< Device Type Qty Amps Total Amps Total HFP-11 0,0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps .tortPanel Battery �d to(ila Current Load: .c ..„ Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -C ©15CD 18 0.0875 1.575 SET -MC -C ©30CD 13 0.131 1.703 SET -MC -C @75CD 0.222 SET -MC -C ©95CD 0.292 SET -MC -C ©110CD 0.259 1ZR-MC ©15CD 14 0.064 0.896 ZR -MC OCD 0.098 ZR -MC ©75CD 0.2 0.03 Amps 5.314 Amps Standby Current Load: 0,03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 5.314 Amps For 5 Minutes 0.446 Amp -hours 25% Derating= 1.458 Amp -hours Total System Current Load: 1.458 Amp -hours • TO NEAREST EXISTING SPEAKER CIRCUIT TO POWER SUPPLY v,v S1-2 30cd V-2 Notification Appliance Circuit Detail !PROJECT: !JIMMY JOHN'S Panel: I EXISTING PAD -3 POWER SUPPLY 'Wire Resistance 2.58 CUR -14 -EN -T-- T-OTAL= 544.50 Date:10ctober 14, 2011 11SET-MC-C ©15CD 87.51 87.51 . , 3 SET -MC -C ©30CD 131 393 1SET-MC-C @75CD 2221 0 SET -MC -C ©95CD 292 0 1ZR-MC ©110CD 1 2591 01 ' 1 .-.ZR-MC.©15CD - . - - ' ' 64 ' ''. 64 0 1ZR-MC ©30CD 1 981 01 0 ZR -MC ©75CD - ' .'. - 175 - -- - 0 DEVICES=15 i TOTAL mA=1 544.5' !Total Wire Resistance ( R ) 1 1 (Total dct Load) , 1(E= I * R) 0.871 „ 24- E) 23.131: Total Device, Load, Amps (I) !Voltage Drop ( E) EOL Voltage 14 308 23.131 544.51 1(WL*2 )*(Rift) 1 1.591 Notification Appliance Circuit Detail, PROJECT: JIMMY JOHN'S Panel: I XLS-V CONTROL PANEL jWire Resistance 2.58 Date: October 14, 2011 CURRENT TOTAL= r#REF! 46 [70.7V1/8 1.81 82.81 . , 26 . 70.7V114 , 3.54 • 92.04 0 170.7V 1/2 1 01 01 0 70.7V1 0 1 DEV10ES=172 1 TOTAL mA=1 174.841 14 SYSTEM CALCULATIONS TO NEAREST EXISTING DATA LOOP IN HALLWAY S1-1 15cd V-1 HT -R S1-3 S1-4 1 5cd 30cd V-3 DI I HT -RI 21-c I TSM s,v,v 8,4441,_ EOL S1-5 30cd V-4 1Total Wire Resistance ( R ) Total Device Load, Amps (I) Voltage Drop ( E) EOL Voltage 1,524 1 19.025086211 174.84 WL * 2 ) * (R/ft) 1, 7.861 (Total Cct Load) 0.17 1(E= 1* R) 1-37 (20.4 - 19.03 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, TEST SWITCH MODULE & RELAY MODULE FOR FAN SHUTDOWN LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 0\ 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS DATE 10/14/11 2 <<<<< 0 co ZTIccoo 0 w ni= - - z Z < Zicc9 w 2z cc= 111 ck) 2 12 cc w .113 Liu LJ co co 0 LU z _J 11.1 z CT) 0 zz 0 0 0 (/) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 1 0/1 4/1 1 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM \..10B NUMBER: r SHEET FA -03 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved} DINING B 100 COOLER & FREEZER 103 ADJACENT TENANT N.I.C. (S) - TO POWER SUPPLY, (V,V) - TO NEAREST SPEAKER CIRCUIT (D) - TO NEAREST DATA LOOP IN HALLWAY A +15'-6" B.O. ROOF DECK PAINT PT -5 DINING A 100 '\ • S1-2 30cd • • FREEZER 6' x 6' ti REFRIG. 6' x 6' • D,S,V,' -0 DS V 4\ • uV •-5-11 15cd STORAGE • 102 10'-6" CLNG. TILE C-1 u S1-3 15cd •' IS1- 30c ®p 11711-1711 • TSM EOL ^ -f S1 S1-5 30cd MALL - N.I.C. NORTH KITCHEN / PREP 101 10'-6"r� CLNG. TILE C-1 'V} T-6" GYP. BD. SOFFIT PAINT PT -4 FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, TEST SWITCH MODULE & RELAY MODULE FOR FAN SHUTDOWN LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. W . 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 10/14/11 2 aaaaa co T Z m co O Lulr C!) � Z �O Z J 1" O <t W �_ W� "_ cc W <=S CC OF— co CV W } N cc uJ �CALE: 1 /4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/ 14/ 1 1 BACKROUND PLAN PROVIDED BY: \0B NUMBER: Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET// FA-04 i �u� aED err sFIRE AL RM SYSTETUKWILA, WASHINGTON t SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLAN 0 Mat Without Comments As Noted In Red Per The Attached Letter 'nese plans have been reviewod by The Tukwila Fire Prevention Bureau for cor:fbr:r?;:;ce with current city standards. Accoptar ce i !:�:rii •ct to errors and omissions which do vic)i tions of adopted stanaaras and o -cwi, ncec,. ..� i�::: fe.; ponsibgity for the adequacy of dssi';n r, tot,Ji+y with the designer. Additions, deletions or ,visions to these drawings atter this date will void tn_.acccpt:$nce -Rnd will require a resubmittal of revised drawings for subsequent approval. Final acceptance is sub .ct to field test and inspection by The Tukwila r.. - v., ' Fife Prevention Bureau. Date: TUKWILA FIRE DEPARTMENT Please call: 575.4402 and give this job No. (*.F -f and exact address for shut. .own or restoration approval, 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO 4114 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO 4116 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2V STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191, CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4- .60 SQUARE INCH 1-1/2' .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9. TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NEPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g_ FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM. SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE T0. DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE. AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE. ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 1 2 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT IFACPI E FIRE ALARM CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT INTERFACE MODULE HTR( -D SIEMENS 4S DEEP VERIFY IN FIELD CONTROL POINT .MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD 1 HZM' I REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS I (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING ®D DUCT SMOKE DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING . VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 IN/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING 2. C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS SET -MC -W SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. 45 DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM SET -HMC -CW SIEMENS 4S DEEP. BOX CEILING W/ 1-1/2" EXT. C FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING L FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2". EXT. TO BOTTOM B WP FIRE ALARM STROBE (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD 1 MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved W ON' O /(N 0' 00 0 N . LL • LO LO N N '0 N J LU RELEASE REV. BY: Z a DESCRIPTION SHOP DRAWINGS FOR AHJ . iu 4/0/08 F- < CI). IICCC < W F-- 0 0 0 J W W Z I 'GALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01 /08 BACKROUND PLAN PROVIDED BY: �OB NUMBER:54503 SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE 'MTH NEPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT YTIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' IDE. SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS DUCT DETECTOR LOCATION o TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC END OF LINE DEVICE(3.6K 1/4W)eT SUPERVISED SWITCH 0 �t- GROUND LO NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 0 d 0 HTRI-R OSTATUS LED CO 0 N.O. r` 0 COM CO 0 0 © TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL v LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE- OUTLET SAMPLING— TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE MUSIC _ —11 -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE J)- STOP IF LAST DEVICE 1- FROM XLS CONTROL PANEL OR : {(�} PREVIOUS ADDRESSABLE DEVICE (-) END OF LINE DEVICE (3.6K 1/4W) RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 riA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST 25 SEC. TO GUARANTEE. DETECTI❑N. 510000 1 2 3..4.5 -6. HCP TB2 0 0 65 O • 0 ; ; • SUPERVISED__:' SWITCH GROUND NOTE: 0 �t- 0 0 Q HTRI-D OSTATUS LED co 0 0 NOT USED 0 FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. -TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL wa Su (FIRE: SUPPRESSION SYSTEM INTERFACE) - 0 GND N AC IV 00 0 PAD -3 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1- 1 2+2-2 NC C NO + -"+ -.+ - + - + - Di El �HI�II I� D13101 24K TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE 2 NAC -4 NAC -3 NAC -2 NAC -1 END OF LINE DEVICE 3.6K 1/4W) UPERVISED WITCH • FRONT VIEW NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP!. Imo_ {FROM XLS CONTROL PANEL OR (+), `PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE POWER SUPPLY C'S' CABLE) FROM FACP. (VOICE CIRCUIT) ('V' CABLE) 470 OHMS IW EOL 0 INPU () 9 9l p T M-1 0 a TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SfAE: NONE (STROBE) SPEAKER (+) ) ( -) STROBE EARTH GROUND NETT DEVICE OR ---=(-) STOP JF LAST DEVICE ( STROBE SPEAKER SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80" APF: 4S DEEP BOX` w/ 1-1/2'.. EXTENSION RING • (SPEAKER STROBE) 4S BOX' (STROBE - ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPEaFICAT1ONS SEE PRODUCT DOCUMENTATION. ORERATMN TEMPERATURE +32'F 0- (O'C TO 100'F (38' C) N 0- UM1DITY: X RELATIVE HUM(TY, NON -CONDENSING HFP-11 SMOKE DETECTOR —� FROM PREVIOUS ADDRESSABLE DEVICE OR POIFJER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FIAIN WEN USED IN CONJUNCTION 14311H DUCT HOUSINGS AD -11P OR AD-11XPR D8-11 STANDARD SMOKE DETECTOR BASE REAR MEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE > (-)DATA OUT > (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING LC) 4 L0 N N 0 O N 1 Lu SPEAKER SUPPORT TILE BRIDGE �-- 4' SQUARE DEEP BOX ioi WITH 1-1/2' EXTENSION z ----CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTI❑N BOX—\ MOUNTED ON• CEILING( FLEX \. Dim- 0 0 / / / JUNCTION BOX -----� J MOUNTED AGAINST CEILING SUPPORT SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE=NONE J �S5 ( TO NEXT DEVICE -----CADDY BAR -- SUSPENDED ILLUMINATED CEILING RELEASE/REVISIONS r CO Lu DESCRIPTION z SHOP DRAWINGS FOR AHJ a.] 0 co 0 0 0 z 0 0 z o07, J � �z 0ocn F-0 zz= arc o 0 QY J LU 0 CCU7= 1 Q N 01) WF- 11/4"...tm W W /SCALE: 1 /8"=1 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01 /08 BACKROUND PLAN PROVIDED BY: �0B NUMBER:54503 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved • 02 SHEET 0 SATELLITE RECEIVER FOR TV ON SELF AT •!-7-0.-' AFF Fi_ASMA TV EOL—S1 18.94V ELECTRICAL PANE! — • C•2 ! ‘.• . .--' S,2V ..------; --&--fr; , •.,-,--,/,‘ . • 1 ! peFEZti'\ FREEZEP 01 TIF AP f!!'' ros ,-(gs 2v •-<:)!! • ------- / FE Ail_ F'APT:Ar?-71.fiC=5-ii OwF C 75 RE1 , -- DOC UNI.C,CKED Wi112‘!!!• OC -5C LIFE OLA,SS STORE FRONT ,REI DISPL•6.si PEFEP CONDIMENT .S1AFICN EMERALD CITY SMOOTHIE WESTFIELD SOUTHCENTER WALL SCALE 1/8'4 ir T!' i'•• NOTES: .•:.! FIELD LOCATE RELAY MODULE FOR BACK' GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE LIF ALL VAV UNITS,(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. • • , . :11! !.• • • . • 5! !!! ! • .- i•I ' •!5'. 5 1,0 CO 0• 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS z DESCRIPTION 0 tI 0 z Ix ct. 0 LL1 CLI CO 0 co 0 z • 1 I : : •!! "- • • '111 •V!'' • • ;si, ! • Copyright• 2006 by Guardian Security Systems, Inc. All Rights ReserveiV. ' 1 i w - co co 1— _1 co < Z w cc 0 (/) /2 2 w cc 0 (I) 0 5 WO-- cc co or) c‘,1 0 ‘CALE: 1 /8" = 1 DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE:5/01 /08 BACKROUND PLAN PROVIDED BY: JOB NUMBER:54503 SHEET FI -03 LJ -D 25 11351 ----- 4. A 7/,. : -14:35 uJ '1140 =a' ft- (-) F F CHAI\IC:'S P') NORTH Li 48 5] ffZ- ci_A_11 (n _J C) ri] fr: L1210 112-i 51 14251 LLI 1-12P ft PM • _ j1A.1 1,190 RECYCLING STOUGE LOADI.' DOCK CHEESECAKE F-A,C TORY : SYSTEM CALCULATIONS LL RISER - ROOM 11 -11 EMERALD CITY SMOOTHIE WESTFIELD SOUTHCENTER MALL SCALE 11321:11 EOL -S1 18.94V EX EMERALD CITY SMOOTHIE EMERALD CITY SMOOTHIE SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations FACP ADD ONS ;: Current Load: Standby: Alarm: Current Load: Standby: Alarm: 1 Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 Main System Board 1 0.03 0.03 0.030 0.030 AD2-P 1 0.0635 0.0635 0.064 0.064 SET -MC @15CD - SET -MC @30CD SET -MC @75CD SET -MC @110CD - SET-HMCC@115CD SET-HMCC@135CD SET-HMG-C@185CD ZR-MC@I5CD ZR -MC @30CD HCP Standby.,'Current Load: 2 0.064 0.098 0.175 0.233 0.048 0.318 0.445 0.064 0.350 HTR -R HTRI-D 2 0.009600 0.0096 0.021 0.042 0.001600 0.0035 If.• ._, " 0.0731 Amps 0.106 ArrIP$ 0.03 0.098 0.0015 Amps 0.38 Amps Standby Current Load: Alarm Current Load: 0.0731 0.106 Amps Amps For 24 Hours = For 5 Minutes= 1.754 0.009 Amp -hours -;„ Amp -hours 0.03 Amps For 24 Hours = 0.720 Amp -hours 25% Derating= 2.204 Amp -hours 11 I! V: • Alarm Current Load: 0.38 Amps For 5 Minutes= 25% Derating= 0.032 0.940 Amp -hours Amp -hours Total System Current Load: 2.204 Amp -hours : 1' 411 • -• Battery Pair to be Used: Total System Current Load: 0.940 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH .11 12VDC Amp -hours 7AH I r 1: 1 ;• BATTERY SIZI G CALCULATION tr. Notification Applianc Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL ..,!:;-, , 1 , ; ; 1 i - - ; Panel EMERALD CITY SMOOTHIE 1 Date: May 5, 2008 Wire Resistance -..3i4-:'-_1:-.--...--.,--..-.-.. i 1.- , i ....i 1 CURRENT TOTAL=I 594 i i CIRCUIT:iS1 1 i I ----; QTY 1 Device Type .__ ..._ __ . • , I . , , 2.46i' 1 0 ;SET -MC ©15CD 0 . SET -MC ©30CD 2 0 ; SET -MC ©75CD !SET -MC ©110CD 1 1 , , ,Alarm CLIIT321e83:830till Alarm Total Wire Size 1! ire Length 1 Voltage at EOL I Circuit Total 1 I 297i 1171 594' 01 0' o ; , i , , ,. , i , , 1 , • i . • . . , i I I 1 1 i Total Wire Resistance ( R ) , : : Total Device Load, Amps (1) ii 1 I ( WL * 2 )* (R/ft) (Total Cot Load) i ' 0.591 0 ' 1SET-HMC-C@115CD ! , Oi 1 :I IVoltage Drop ( E ) , 1.46i i , 1 0 ' ! SET-HMC-C@177CD ' 4451 01 i i (E= I * R) , 0 SET -HMC @135CD ;., 318 01 ! f i i I EOL Voltage I 1894' i i 4451 (20.4 - E) , SET -HMC @185CD . 0 1 , , , 0 i 1 1Z-MCgl 5CD i 1 , ! 1 ; , 0 . , . , 0 1 1Z-MC©30CD ' 1 2001 01 0 264' -I- SET-MC-CW@110CD i0 1 i 1 , , II i ! DEVICES= i2 i TOTAL m A= I , 1 , 594i 12 i 1 380 18.9373344 594 i , • .. i ._ ....... .. notification Appliance cuit Detail ! I : , . PROJECT: WESTFIELD SOUTHCENTER MALL, , , , Panel: EMERALD CITY SMOOTHIE :Wire Resistance 5.16 • Date' April 21, 2008 ,i, . CURRENT TOTAL= Ii 3.6 , CIRCU IT: i SPEAKER CIRCUIT f ; ; It . ; : , i QTY , Device Type Alarm Current I Alarm Total ! VVire Size i VVfr',9 Letigth Voltage at EOL i Circuit Total , , ,-- 2 170.7V1/8 f; . 361 . t ' ? ',i' . 1 ; ! I Tota I Wire Resistance ( R ) , 7.99 0i ..,... , 181 , i , • - --I 0' (‘) i.„ . i ( WL * 2 )* (R/ft) r1' i I ' ! 0 01 0 d 1 ; 0.00! i -1 r--- : - i Total Device Load, Amps (1) i I iit ; ! { 0 I 0 1 , 0 1 Il ' I ! i (Total Cct Load) , i 0 0! 01 f .'t.1 , . , 1Voltage Drop ( E 0 - 01 01 1 ,-) 1 (E= I * R) _ i $ r -ii 0 I 0 1 1 0 I ; ; : Y i , , . i -,EOL Voltage , . 20.37i . o = , 0; 0 ; i 1 ' . i 1 (20.4 - E) , 1 • 0 t :t : , i i •. 0 ,, i o 1 , o o i o i i: , t ii :. i DEVICES=2 z iTOTPL mA=1 6 3.i 12 i j• 774 ! 20.37124435 3 .6 . , 1 _., • -/•••••• 1•C• •• ••••• • • .• .- • ••,.• • ..- .••••• a, • ••••• a'. , . ,••••• . ...••• • , -, t 1 1 t 1 i I ••-- ti RISER DIAGRAM •VOLTAGE DROP CALCULATION a t) c0 0\ z 0 CD C) uJ LLJ (I) c; cn z FAX (206) 628-4990 RELEASE/REVISIONS 03 LU Ct DESCRIPTION SHOP DRAWINGS FOR AHJ co LU 0 z < < w. F- co co 7 0 04 0 <(3 ) 2 Z W CC CI) rn z Z 2 w �0(/) 0 5 FT.-•' a w 0, I u)--1 EI co (NI CC h` LLI } cc 0 . , >-- cif) } 4CALE: 1/8"=1' DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01 /08 BACKROUND PLAN PROVIDED BY: • NUMBER:54503 ,} SHEET 3- Copyright 2006 by Guardian Security Systems, Inc. All Rights ReServed FA -04 DINING B 100 jib ±15'-6" B.O. ROOF DECK DINING A COOLER & FREEZER ADJACENT TENANT N.I.C. NO CEILING ABOVE COOLER & FREEZER •w Z 0 I- 0 < H KITCHEN /PREP 101 10'-6" ank CLNG. TILE C-1 NU T-6" iink GYP. BD. SOFFIT PAINT PT -4 MALL - N.I.C. Design per NFPA 13, Ordinary Hazard All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart }i 1 — Add Viking Model VK154 Standard Response 155° Dry Pendent '/2 x 1/2 • 9 — Add Reliable Model F1 Standard Response 1550 Pendents 1/2 x 1/2 o 8 — Add Reliable Model F1 Standard Response 155° Upright 1/2 x '/2 Total = 18 REFLECTED CEILING PLAN 1/4"=1'-0" 1 • RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING HANGER DETAIL NTS ❑ Without Comments 0 As Noted in Red l' Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of. adopted standards and ordinances. The responsibility for the dequ3cy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void ti rs acceptance and will require a resubmittal of revised drawirgis for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau.__ -I 3-1 / Ev: / 1 TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address for shut - 'down or restoration approval. NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic teat t � aa'aat. C 140X1}4 • MALL KEY PLAN -1ST FLOOR K,s BROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7869 JIMMY JOHN'S 728 SOUTHCENTER MALL, SUITE 1480 TUKWILA, WA 9.8188 PAID SEP -1 2011 TUKWILA FIRE DATE:; ? 0 IE DRAWN: SCALE: I' 9 / be GENERAL LEGEND --4 —D —4 BOO BOB BOJ FOS FOW EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPLING ( UNLESS NOTED ) CAP PLUG CENTERUNE HYDRAULIC REFERENCE POINT CENTERUNE PIPE TO BOTTOM OF DECK CENTERLINE PIPE TO BOTTOM OF BEAM CENTERUNE PIPE TO BOTTOM OF JOIST FACE OF STUD FACE OF WALL FOC AFF CH R.C. E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR CEIUNG HEIGHT REDUCING COUPUNG OUTLET COUPLING WELDED OUTLET "FIT" FITTING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALSO "Gr) THREAD/"FlT" (ALSO "Fxr) ALL -THREAD ROD , - s 153tki - ;re‘i•k..ii•+,.. • 4 1 - , -'!"•*1":1'). 47'4 •!.1.• I• :V, IC ' -11 _ et;* - ' • ' -$ Wolt pg.!" tS),c - - • ' f4tVI - - at- ' ' ,....,... .V.- • ...4.'s a .,,,rf.. 4" .04 4!',. .........wr,-,,,,-- . i i's 4 • V' ti.V.4 exit:V-1'a ' ts4-• ' .4":. . . - (7, :7,-.47:i. i4o, a.i....1.1, . •,.......1,; ";,',...44, -.1i4;4-.-c,, • -1. .. - •:' 1.' 4 S 141 F ;17. 4.1 t • , . It) P. ; st.r. Vovr Aft F.4 •4 4 . 44:•iittr 5111. • II_•.etra'' CkPir- alaa, • -4 sa. Alt : 7 Ittdt Dt a EMERALD CITY SMOOTHIE TENANT SPRINKLERS 0 RELIABLE MODEL F1 -FR QUICK RESPONSE RECESSED CHROME PENDENT 1/2" 155' 1 TUKWILA FIRE DEPARTMENT Please call: 575-440Z and give thls job No. 03 S-0.9(0 and exact address for shut. . ,wn or restoration aoorovA, Ii44414M.44:44.15. •••-• i . mlne rEra Tr -.71 ra--1 Without Comments As Noted In Red Per The Attached Letter nese plans have been reviewed by The Tukwila Fire Prevention Bureau for corifomince with current city standards. Acceptance Cu errors and . omissions Which do no', of adopted standards and Tf for the adequacy of \•. ti; •Additions, dc)ier.;0,:-.;; 0: -‘4'ings atter this date Vii l void v./1 ceq&e a resubmittal of revised (1,:mi-igs for r3ubsequent approval Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: LI- By: kk,1 3-1 QTY 12 PROJECT TOTAL: 12 1 11( 2'X 4' GRID IN BACK OF HOUSE C.D (I) X uJ ALL LIGHTING IN BACK OF HOUSE TO BE CENTERED IN CEILING 'TILES STEPED SOFFIT OVER MENU BOARD WALL LAYERED CLOUD OVER SERVICE COUNTER GWB CEILING TRACK LIGHTING D1OTICE Weld stamps must be inspected before pipe is hung. Do not paint piping pri4.)r to hydrostatic test aFovL LEGEND EXISTING PIPING 1•14•41•111111 NEW PIPING J \ / 15! 1! V IA 3- 3— i 0 J t"'L-4/1 FR / il11001 11/2 11/2 10-2 4 10-2 k, <1 2-4 ,O• TENANT SPRINKLER PLAN SCALE: 1/4" = 1 '-0" GENERAL NOTES g\7 SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 - 2007 ED ALL MATERIALS SHALL BE NEW AND U.L. USTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 ALL ELECTRICAL PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS SPRINKLER HEADS TO BELOCATED IN CENTER POINT OR QUARTER POINT OF CEILING TILE TENANT SHELL SPRINKLER SYSTEM ORIGIANLLY CALCULATED FOR ORDINARY HAZARD GP 2 - .20 / 1500 SF ORDINARY HAZARD OCCUPANCY: 130 S.F. PER SPRINKLER MAX NEW PIPING TO BE 'DYNA-THREAD' THREADABLE 11-IINWALL nourish your body • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 Pfl. (425) 481-7669 Emerald City Smoothie 728 SOUTH Level 1 - Suite 1480 Tukwila, WA 90025 DATE 03/08 DRAWN: C.A. AY. DA D r 2 2008 SCALE: NOTED Tukwila Fire 1 OF 1 GENERAL LEGEND -r- -4 ROD BOB BOJ FOS FOW EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPLING ( UNLESS NOTED ) CAP PWG CENTERLINE HYDRAULIC REFERENCE POINT CENTERLINE PIPE TO BOTTOM OF DECK CENTERLINE PIPE TO BOTTOM OF BEAM CENTERLINE PIPE TO BOTTOM OF JOIST FACE OF SND FACE OF WALL FOC AFF CH R.C. 4 E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR CEILING HEIGHT REDUCING COUPUNG OUTLET COUPUNG WELDED OUTLET "FIT" FITTING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALSO "GTA) THREAD/Fr (ALSO "FxT") ALL -THREAD ROD EMERALD CITY SMOOTHIE TENANT SPRINKLERS • RELIABLE MODEL F1 -FR QUICK RESPONSE RECESSED CHROME PENDENT 1/2" 155' QTY 12 PROJECT TOTAL: 12 (PIPING LEGEND 111010 MOMMall EXISTING PIPING NEW PRIG 2'X 4' GRID IN BACK OF HOUSE • 1 ALL LIGHTING IN BACK OF HOUSE TO BE CENTERED IN CEIUNG TILES STEPED SOFFIT OVER MENU BOARD WALL LAYERED CLOUD OVER SERVICE COUNTER GWB CEILING TRACK LIGHTING .CLG. TENANT SPRINKLER PLAN SCALE: 1/4" = 1'-0" GENERAL NOTES O� D SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 - 2007 ED ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS SPRINKLER HEADS TO BELOCATED IN CENTER POINT OR QUARTER POINT OF CEILING TILE TENANT SHELL SPRINKLER SYSTEM ORIGIANLLY CALCULATED FOR ORDINARY HAZARD GP 2 - .20 / 1500 SF ORDINARY HAZARD OCCUPANCY: 130 S.F. PER SPRINKLER MAX NEW PIPING TO BE 'DYNA-THREAD' THREADABLE THINWALL 5.Z 01-P s 5u;i4 CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Emerald City Smoothie 728 SOMICENTER P AY Level 1- Suite 1480 op- 5 - 9� Tukwila, WA 25 DATE: 03/08 I DRAWN: C.A. I SCALE: NOTED 1 OF 1 728 SOUTHCENTER MALL ASSOCIATED PERMITS 11-F-281 11-F-241 08-F-169 11-S-204 08-S-096 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: -T" ? g � r 1A/10.\\ Suite Number: No Floor: Tenant Name: rmy -31)1(\ riS New Tenant? Yes ❑ - No k'�\Property Owner's Name: \- A( �1 1� �� Y"19 C v Mailing Address: 1 \bC).`w \snki-e__ eF:s1\43„ /1\ , Los ,cieae s , Cly g CO2S City State Zip CONTACT PERSON -if there are questions about the submittal. Name: c S`CQ 010I VISO() 1-712.11-87-7(o(6? Day Telephone: Company Name: CV, 1 w e T"1 rtC,C+k Cir), 1V1C_, Mailing Address: Box ` G--\ 1 1' 1 l ee z.1 q w $'7 XJ E-mail Address:de SS\ C) C rtkoin • Cb Yfl City Fax Number: Liam ggitg cA Valuation of Project (contractor's bid price): $ l ,CC) Scope of Work (please provide detailed information): Mak_ C -V > -� \rte \n-611(1� PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING N�ERR OR AUT D AGENT: Signature: .aa l CQ Print Name: 3PSCIVGit71 YIDf Plan Permit App.doc Date: RkSkA Day Telephone: 1-12— $1-1piCl9 5/14/10 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 4AZTZ$ SINAJAI e2. 9{ r C / Suite Number: Floor: Tenant Name: 310.1J�`o(v4:6- Property Owner's Name: 7 i- � i& (Kcal. Mailing Address: New Tenant? - Yes ❑ - No CONTACT PERSON -if there are questions about the submittal. Name: cs. ck,e_ City State Zip Day Telephone: C o6) 3 S I Z6 & . Company Name: Cs-� d-, et" C tZC'A"r `-)"v 0tict Mailing Address: t Ttt Of' l- S t 3 City / State Zip E-mail Address: r 'C� u �,0`"` �-'-+ ` Fax Number: C`u%6� 3 4 6t t7 Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Ftp vh s PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested m writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: (0/21/ I ) Print Name: k2- 5` L Plan Permit App.doc Day Telephone: C2)Y /2-6 g 5/14/10 TFD FP Form 8 MIN SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: WA Site Address: 7 23 SL M intik Suite Number: 1 ti SO Floor: Tenant Name: .J i vv r .3.:1101 h S New Tenant? ❑ - Yes Z1- No Property Owner's Name: `tib S 4- old Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: �0.e.c) e_. F Kik-t Company Name: U.,rdci, Se. CAA.r-1 y Mailing Address: i i? t 9 � S O i Sect- L' , LA 'TS 1 34 E-mail Address: f kic1City State Zip � 3u t a'^Se 2 t.v i C.it+► Fax Number: Cac�4a7 3Z11c{ Q'Z& Day Telephone: C2 )3S9 I 2.15 Valuation of Project (contractor's bid price): $ 3, ) 00 i Scope of Work (please provide detailed information): Part i �n 2 ee.da_.) 0.".d 2 5 wvo vv.._ a (ca -c", s.,)c key., ckeJe c {'o r S - PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: 1 Print Name:pt� L� Plan Permit App.doc Date: 2142.g/ 11 Day Telephone: t 2.96) �jS 1 7 GE 5/14/10 TFD FP Form 8 • FILE COPY FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Emerald City Smoothie 728 Southcenter Mall Permit No.: 08-S-096 Date: April 1, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. All references are NFPA 13, 2007 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Jimmy John's 728 Southcenter Mall Permit No.: 11-S-204 Date: September 13, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. JIMMY JOHN'S NEW FIRE DAMPERS FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUN3ER SHEET TITLE FA -01 SYSTE \A INFOv1ATIO\ FA -02 CALCULATION, WRING DIAGRAV A\D SINGLE LINE DIAGRAM FA -03 FRE ALA M SYSTEM PLA SHEET INDEX Without Comments O As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date•L2,-1)9-14 By: W NOTICE A completed, signed, Tukwila Fire Depa[tment Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. TUKWILA FIRE DEPARTMENT Please call 205-575-4407 and give is Fire Permit No. and exact address for shut- down or restoration approval. =DULE A\D CONDUIT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NEPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY 2 2 EX EX EX EX EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT HTR -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING DUCT DETECTOR DEX AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR EX TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HTR -R INTERFACE MODULE HTRI-R Ex WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD DEX FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXTN FIRE ALARM EX STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A -N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N /A N/A N/A N/A SYMBOLS LEGEND \1 l NORDSTROM 3 LEVELS 171,275sf ES=R_SSO macys 4 LEVELS 250,4C7sf JIMMY JOHN'S 728 ,ne LEVELS vyivs 2 7, B IME i-- SIA:a�A<5 4 F°:,71.,,. ?clyY[ 'IF RAS 4:+5 IIME_AR Il 3EYER 4 COLD G CLErv, AK' S;.W^�AS', .-sae LE 1.5 w.cLErsoo<S YALE =1 NAS.':v1CN UTNE tar5 STAR3xS •Y ;^LE PAOCC SYY(F_AP ,CTNER;cco FIERQNC PASCCA B+SCM ❑ 'la 5 ,NM R.a w a P.AYTpM a R. [ SEARS 2eW raw.. ELL- ra-LELL MAL RESTIaRLINT 'ATO SITE PLAN PESTALVIT ATO �+�Stift IWS,LE !:'I. crier '_,PIRt 1. £A1c S E� 1 . REST'. ▪ JCPenney • 3 LEVELS 275,46ao f PAID DEC 28 2011 TUKWILA FIRE 03 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: CD M 0 DESCRIPTION SHOP DRAWINGS DATE N .2aaaaa C!) CC W 0 c T co 00 QWr W E - O) CC o ) J or W W () wQ C12IIICC z D co te `r I I _ Z 0 cc 0 )1- N �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:12/ 19/ 1 1 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 55361_1 �i FA -01 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET DATA ❑UT DATA IN C O 0 s 00 N/❑ c N/C 0 8 7 6 c DOWEI PA\EL 0 O H DAIVPE. DAV PES 120VAC FSD POWER TO 3E PROVIDED BY OTHE FIRE SMOKE DAMPER SHUT -DOWN WIRING DETAIL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERIIN TEMPERA RE: +32' F 0- C) TO 100 F 36 C) HUMIDITY: 0- 9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR �1 -> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR �- DB -11 STANDARD SMOKE DETECTOR BASE fDATA IN (-) �— DATA IN (+) > > TO NEXT ADDRESSABLE (+) DEVICE SMOKE DETECTOR WIRING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINS CEILING SUPPORT -00 0 0 IL T❑ NEXT DEVICE CADDY BAR SMOKE DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL TYPICAL WIRING AND MOUNTING DIAGRAMS TO NEAREST EXISTING SPEAKER CIRCUIT ( TO POWER SUPPLY TO NEAREST EXISTING DATA LOOP IN HALLWAY i$ Tfi; '�� si�lf DMG I f t f r Y DESCRIPTION SHOP DRAWINGS Current Load: 0) N Standby: Alarm: z<aaaa Device Type Qty Amps Total Amps Total HFP-11 2 0.0022 0.0022 ° 0.0023 0.005 AD2-P 1 0.0635 0.0635 0.064 0.064 H1R-R 4 0.009600 0.0096 . 0.021 0.084 0.0731 Amps 0.148 Amps V,V' CALCULATIONS S1-2 30cd V-2 EX s,s',v,v' FLAG NOTES: FIELD LOCATE RELAY MODULE WITHIN 3 FEET OF FIRE SMOKE DAMPER. 120VAC FIRE SMOKE DAMPER POWER TO BE PROVIDED BY OTHERS. FIELD LOCATE SMOKE DETECTOR WITH 5 FEET OF FIRE SMOKE DAMPER. s,V,V' s,V,V' V S,V,V' D EX S1-1 15cd 15cd V-1 S1-3 EOL EX EX EX S1 S1-4 S1-5 30cd 30cd V-3 V-4 D D,I IHT-RIEX 214 TSM EX SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE 0) N z<aaaa SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:12/19/1 1 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 55361 J SHEET FA -02 COOLER & FREEZER 103 (S) - TO POWER SUPPLY, (V,V) - TO NEAREST SPEAKER CIRCUIT ADJACENT & TENANT N.I.C. (D) - TO NEAREST DATA LOOP IN HALLWAY A \\\\\ SFD� _.__�).{,i R 1 DINING B 100 U 0 I¢ Z W +15'-6" B.O. ROO DECK PAINT PT - DINING A 100 L FREEZER 6' x 6' 1 HT -R REFRIG. 6' x 6' D I' I • \i\ D S,VV; \\\\\\\\\\\ \\ STORAGE 102 10'-6" 15cd EX S1-3 15cd • II 7 /I \i CLNG. TILE C-1 TSM KITCHEN/PREP 101 10'-6" CLNG. TILE C-1 7'-6" GYP. BD. SOFFIT PAINT PT -4 HT -R S1-5 30cd MALL - N.I.C. FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE WITHIN 3 FEET OF FIRE SMOKE DAMPER. 120VAC FIRE SMOKE DAMPER POWER TO BE PROVIDED BY OTHERS. FIELD LOCATE SMOKE DETECTOR WITH 5.FEET OF FIRE SMOKE DAMPER. Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 0) Z N I <<<<< W LL. SCALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:12/ 19/ 1 1 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 55361 SHEET f FA -03 SHEET NUMBED SHEET TITLE ? � Y s S t fi 1 fLJC31---LNT'!t f } FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON FA -01 SYSTEM I\ FO MATION FA -02 TYPICAL WRING A D MOUNTING DETAILS FA -03 SYSTEM CALCULATIO\S AND SINGLE LINE DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the ydequacy of design rests totally with the designer. Additions, deielons or revisions to these drawings after his date will void this acceptance and will require a resubmittal Of revised drawings for subsequent approval. final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Buri au. Date: By: W J I I TUKWILA FIRE DEPARTMEN Please call 206-575-4407 and give this ire Penni' No. Il- --(XL)1 and exact address for shut- down or restoration approval, RULE A NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. \D CONDUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLJFPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPUFPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPUFPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 4 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ®D DUCT DETECTOR AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HTR -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXTN FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND JIMMY JOHN'S' 728 mervyn's 2 LEVELS :5,__'sf 250.407sf h NORDSTROM 3 LEVEL S 171,275sf 'I+E RA,E *SE tl•f.UM 3lN_R 4 f:Clf) 0 LLDO,Sia<s C LICE A T^ C(4PT 12-".+APf :44 • JCPenney 3 LEVELS 276,•168 f ° 0. n P,AYTIX 1 PATO RESTAtPANT ATO RETAIL RESTAI WR ATO WIRE DESIGNATION GENERAL NOTES SITE PLAN 1.1 PAID OCT 21 2011 TUKWILA FIRE -2av 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 1 0/1 4/1 1 2<aaaa co d- T ; Z 00 O�� Z Q ..o J~ 0 LIU ›. tow¢ <HEw CC O� co 0 6ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/14/11 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved BACKROUND PLAN PROVIDED BY: 1.0B NUMBER: SHEET � FA -01 12OVAC-6 1Z DEDICATED EMERGETNCY l THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. PUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL FATE: FOR ODO M AL SPE0ff1CA110NS SEE PRODUCT DCCUBENTA110N. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FROM TO NEXT ADDRESSABLE C IP DEVICE STIF LAST DEVICE - FROM XLS comTRIIt. PANEL (1 OR PREVIOUS ADDRESSABLE DEVICE - 0 O 0 HTRI-R o NOTE: FSEEEE PACT DDOCUMEENl CATIONAL Os C -CABLE C -CABLE 00 0 PAD -3 00° INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1- 1 2+2- 2 NC C NO + - + - + - + - + - (-) (+) ee SPARE SPARE SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) D❑ NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. m 5 P1 m 0 0 PI PI 0 C (=)(-) (+)(+) 4 (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIED #18 FPLIFPIR RED (JACKET) *CONTACT RATQNC& 4.0A 0 125VAC 4.OA 0 30VOC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O a * 1 0 a 0 HTRI-R 0 r-7 1-6 c4 DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. _ l GROUND ��\ (+)> TO NEXT DEVICE OR O ❑n _tel 111 — i DMG I ❑ '�,�/, ,110( y + _ISI III 0 a O T°A. J - w� 7 7 r ' '€ ;1; Si;' 'I1;► +— Attetnt . AICIEFIIIIx :2 gf1 q I II ha2 I:1:1:1:111:1:1* 1:11:1:1 I CCI. PI v '09 41.11 X V _i— ��jt1• ill 4 0 114❑ p <a 'i :1 1/ '.� 7 !I o 0❑ (-) POWER SUPPLY & RELAY MODULE WIRING DETAIL FROM PRECEDING SPEAKER (+) (+) (-) STOP IF LAST DEVICE DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL STROBE SPEAKER •y _ 0 DMG ■ — _ , ,110( y + _ISI III 0 a O O J - w� 7 7 r ' '€ ;1; Si;' 'I1;► +— Attetnt . AICIEFIIIIx :2 gf1 q I II ha2 I:1:1:1:111:1:1* ,01.:- I:I I:I:I I I:1:1b PI v '09 41.11 O O — —7 ��jt1• ill 4 0 114❑ p <a 'i :1 1/ '.� CIRCUIT D❑ STROBE ❑DDI CIRCUIT =❑ STROBE 40❑ 1 1 O — DMG - _ — _ ❑ , ,110( y SHOP DRAWINGS _ISI III 0 u l� O 'E, (. -/wan O (J� S " T n+ 'I1;► +— Attetnt . 11B8H81198 �''-� . +- AtCOIF$N " • q ` y ,01.:- I:I I:I:I I I:1:1b PI v '09 41.11 Iti — ill 4 0 114❑ p <a 'i :1 (-) (-) OR FIRE ALARM CONTROL PANEL < (-) SPEAKER CIRCUIT (+) (+) Dnu STROBE SPEAKERISTROBE 1n0 01E1 ■10 — - DMG O❑f 10°01 I❑0 y SHOP DRAWINGS _ISI III 0 O 'E, (. -/wan 0 n+ +— Attetnt 11B8H81198 �''-� . q ` y = PI v '09 41.11 ill 4 IDD (-) STROBE (-) SPEAKER CIRCUIT SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS (+) (-) SPEAKER CIRCUIT 5 TO NEXT APPLIANCE S OR 24K (EOLR) TO NEXT SPEAKER S OR END OR LINE RESISTOR 24K (EOLR) NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER T1N TEMPERA RE: +32' F (0' C TO 100' F 3LT C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —' FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOaTY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR �— DB -11 / STANDARD SMOKE DETECTOR BASE (+) SMOKE DETECTOR WIRING DETAIL HARD LID CEILING > TO NEXT > ADDRESSABLE DEVICE SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSION N CEILING MOUNTED SPEAKER/STROBE X SPEAKER STROBE MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX \\` � ______547) -Jim JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT SMOKE/HEAT DETECTOR TO NEXT DEVICE CADDY BAR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved W ti FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 0 0 co T 00 O w 01) z 9°z _ `C O� OdC W �z ›- CI) w cc w w� CC ©F-- co N 1` z O 0 z c� z J U �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/ 14/ 1 1 BACKROUND PLAN PROVIDED BY: \0B NUMBER: SHEET FA -02 111 ' - I' JIMi. 0 0 DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: 10/14/11 2 <<<<< Device Type Qty Amps Total Amps Total HFP-11 0,0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps .tortPanel Battery �d to(ila Current Load: .c ..„ Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -C ©15CD 18 0.0875 1.575 SET -MC -C ©30CD 13 0.131 1.703 SET -MC -C @75CD 0.222 SET -MC -C ©95CD 0.292 SET -MC -C ©110CD 0.259 1ZR-MC ©15CD 14 0.064 0.896 ZR -MC OCD 0.098 ZR -MC ©75CD 0.2 0.03 Amps 5.314 Amps Standby Current Load: 0,03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 5.314 Amps For 5 Minutes 0.446 Amp -hours 25% Derating= 1.458 Amp -hours Total System Current Load: 1.458 Amp -hours • TO NEAREST EXISTING SPEAKER CIRCUIT TO POWER SUPPLY v,v S1-2 30cd V-2 Notification Appliance Circuit Detail !PROJECT: !JIMMY JOHN'S Panel: I EXISTING PAD -3 POWER SUPPLY 'Wire Resistance 2.58 CUR -14 -EN -T-- T-OTAL= 544.50 Date:10ctober 14, 2011 11SET-MC-C ©15CD 87.51 87.51 . , 3 SET -MC -C ©30CD 131 393 1SET-MC-C @75CD 2221 0 SET -MC -C ©95CD 292 0 1ZR-MC ©110CD 1 2591 01 ' 1 .-.ZR-MC.©15CD - . - - ' ' 64 ' ''. 64 0 1ZR-MC ©30CD 1 981 01 0 ZR -MC ©75CD - ' .'. - 175 - -- - 0 DEVICES=15 i TOTAL mA=1 544.5' !Total Wire Resistance ( R ) 1 1 (Total dct Load) , 1(E= I * R) 0.871 „ 24- E) 23.131: Total Device, Load, Amps (I) !Voltage Drop ( E) EOL Voltage 14 308 23.131 544.51 1(WL*2 )*(Rift) 1 1.591 Notification Appliance Circuit Detail, PROJECT: JIMMY JOHN'S Panel: I XLS-V CONTROL PANEL jWire Resistance 2.58 Date: October 14, 2011 CURRENT TOTAL= r#REF! 46 [70.7V1/8 1.81 82.81 . , 26 . 70.7V114 , 3.54 • 92.04 0 170.7V 1/2 1 01 01 0 70.7V1 0 1 DEV10ES=172 1 TOTAL mA=1 174.841 14 SYSTEM CALCULATIONS TO NEAREST EXISTING DATA LOOP IN HALLWAY S1-1 15cd V-1 HT -R S1-3 S1-4 1 5cd 30cd V-3 DI I HT -RI 21-c I TSM s,v,v 8,4441,_ EOL S1-5 30cd V-4 1Total Wire Resistance ( R ) Total Device Load, Amps (I) Voltage Drop ( E) EOL Voltage 1,524 1 19.025086211 174.84 WL * 2 ) * (R/ft) 1, 7.861 (Total Cct Load) 0.17 1(E= 1* R) 1-37 (20.4 - 19.03 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, TEST SWITCH MODULE & RELAY MODULE FOR FAN SHUTDOWN LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 0\ 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS DATE 10/14/11 2 <<<<< 0 co ZTIccoo 0 w ni= - - z Z < Zicc9 w 2z cc= 111 ck) 2 12 cc w .113 Liu LJ co co 0 LU z _J 11.1 z CT) 0 zz 0 0 0 (/) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 1 0/1 4/1 1 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM \..10B NUMBER: r SHEET FA -03 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved} DINING B 100 COOLER & FREEZER 103 ADJACENT TENANT N.I.C. (S) - TO POWER SUPPLY, (V,V) - TO NEAREST SPEAKER CIRCUIT (D) - TO NEAREST DATA LOOP IN HALLWAY A +15'-6" B.O. ROOF DECK PAINT PT -5 DINING A 100 '\ • S1-2 30cd • • FREEZER 6' x 6' ti REFRIG. 6' x 6' • D,S,V,' -0 DS V 4\ • uV •-5-11 15cd STORAGE • 102 10'-6" CLNG. TILE C-1 u S1-3 15cd •' IS1- 30c ®p 11711-1711 • TSM EOL ^ -f S1 S1-5 30cd MALL - N.I.C. NORTH KITCHEN / PREP 101 10'-6"r� CLNG. TILE C-1 'V} T-6" GYP. BD. SOFFIT PAINT PT -4 FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, TEST SWITCH MODULE & RELAY MODULE FOR FAN SHUTDOWN LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. W . 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 10/14/11 2 aaaaa co T Z m co O Lulr C!) � Z �O Z J 1" O <t W �_ W� "_ cc W <=S CC OF— co CV W } N cc uJ �CALE: 1 /4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/ 14/ 1 1 BACKROUND PLAN PROVIDED BY: \0B NUMBER: Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET// FA-04 i �u� aED err sFIRE AL RM SYSTETUKWILA, WASHINGTON t SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLAN 0 Mat Without Comments As Noted In Red Per The Attached Letter 'nese plans have been reviewod by The Tukwila Fire Prevention Bureau for cor:fbr:r?;:;ce with current city standards. Accoptar ce i !:�:rii •ct to errors and omissions which do vic)i tions of adopted stanaaras and o -cwi, ncec,. ..� i�::: fe.; ponsibgity for the adequacy of dssi';n r, tot,Ji+y with the designer. Additions, deletions or ,visions to these drawings atter this date will void tn_.acccpt:$nce -Rnd will require a resubmittal of revised drawings for subsequent approval. Final acceptance is sub .ct to field test and inspection by The Tukwila r.. - v., ' Fife Prevention Bureau. Date: TUKWILA FIRE DEPARTMENT Please call: 575.4402 and give this job No. (*.F -f and exact address for shut. .own or restoration approval, 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO 4114 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO 4116 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2V STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191, CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4- .60 SQUARE INCH 1-1/2' .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9. TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NEPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g_ FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM. SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE T0. DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE. AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE. ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 1 2 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT IFACPI E FIRE ALARM CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT INTERFACE MODULE HTR( -D SIEMENS 4S DEEP VERIFY IN FIELD CONTROL POINT .MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD 1 HZM' I REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS I (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING ®D DUCT SMOKE DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING . VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 IN/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING 2. C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS SET -MC -W SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. 45 DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM SET -HMC -CW SIEMENS 4S DEEP. BOX CEILING W/ 1-1/2" EXT. C FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING L FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2". EXT. TO BOTTOM B WP FIRE ALARM STROBE (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD 1 MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved W ON' O /(N 0' 00 0 N . LL • LO LO N N '0 N J LU RELEASE REV. BY: Z a DESCRIPTION SHOP DRAWINGS FOR AHJ . iu 4/0/08 F- < CI). IICCC < W F-- 0 0 0 J W W Z I 'GALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01 /08 BACKROUND PLAN PROVIDED BY: �OB NUMBER:54503 SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE 'MTH NEPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT YTIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' IDE. SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS DUCT DETECTOR LOCATION o TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC END OF LINE DEVICE(3.6K 1/4W)eT SUPERVISED SWITCH 0 �t- GROUND LO NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 0 d 0 HTRI-R OSTATUS LED CO 0 N.O. r` 0 COM CO 0 0 © TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL v LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE- OUTLET SAMPLING— TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE MUSIC _ —11 -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE J)- STOP IF LAST DEVICE 1- FROM XLS CONTROL PANEL OR : {(�} PREVIOUS ADDRESSABLE DEVICE (-) END OF LINE DEVICE (3.6K 1/4W) RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 riA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST 25 SEC. TO GUARANTEE. DETECTI❑N. 510000 1 2 3..4.5 -6. HCP TB2 0 0 65 O • 0 ; ; • SUPERVISED__:' SWITCH GROUND NOTE: 0 �t- 0 0 Q HTRI-D OSTATUS LED co 0 0 NOT USED 0 FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. -TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL wa Su (FIRE: SUPPRESSION SYSTEM INTERFACE) - 0 GND N AC IV 00 0 PAD -3 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1- 1 2+2-2 NC C NO + -"+ -.+ - + - + - Di El �HI�II I� D13101 24K TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE 2 NAC -4 NAC -3 NAC -2 NAC -1 END OF LINE DEVICE 3.6K 1/4W) UPERVISED WITCH • FRONT VIEW NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP!. Imo_ {FROM XLS CONTROL PANEL OR (+), `PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE POWER SUPPLY C'S' CABLE) FROM FACP. (VOICE CIRCUIT) ('V' CABLE) 470 OHMS IW EOL 0 INPU () 9 9l p T M-1 0 a TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SfAE: NONE (STROBE) SPEAKER (+) ) ( -) STROBE EARTH GROUND NETT DEVICE OR ---=(-) STOP JF LAST DEVICE ( STROBE SPEAKER SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80" APF: 4S DEEP BOX` w/ 1-1/2'.. EXTENSION RING • (SPEAKER STROBE) 4S BOX' (STROBE - ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPEaFICAT1ONS SEE PRODUCT DOCUMENTATION. ORERATMN TEMPERATURE +32'F 0- (O'C TO 100'F (38' C) N 0- UM1DITY: X RELATIVE HUM(TY, NON -CONDENSING HFP-11 SMOKE DETECTOR —� FROM PREVIOUS ADDRESSABLE DEVICE OR POIFJER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FIAIN WEN USED IN CONJUNCTION 14311H DUCT HOUSINGS AD -11P OR AD-11XPR D8-11 STANDARD SMOKE DETECTOR BASE REAR MEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE > (-)DATA OUT > (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING LC) 4 L0 N N 0 O N 1 Lu SPEAKER SUPPORT TILE BRIDGE �-- 4' SQUARE DEEP BOX ioi WITH 1-1/2' EXTENSION z ----CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTI❑N BOX—\ MOUNTED ON• CEILING( FLEX \. Dim- 0 0 / / / JUNCTION BOX -----� J MOUNTED AGAINST CEILING SUPPORT SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE=NONE J �S5 ( TO NEXT DEVICE -----CADDY BAR -- SUSPENDED ILLUMINATED CEILING RELEASE/REVISIONS r CO Lu DESCRIPTION z SHOP DRAWINGS FOR AHJ a.] 0 co 0 0 0 z 0 0 z o07, J � �z 0ocn F-0 zz= arc o 0 QY J LU 0 CCU7= 1 Q N 01) WF- 11/4"...tm W W /SCALE: 1 /8"=1 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01 /08 BACKROUND PLAN PROVIDED BY: �0B NUMBER:54503 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved • 02 SHEET 0 SATELLITE RECEIVER FOR TV ON SELF AT •!-7-0.-' AFF Fi_ASMA TV EOL—S1 18.94V ELECTRICAL PANE! — • C•2 ! ‘.• . .--' S,2V ..------; --&--fr; , •.,-,--,/,‘ . • 1 ! peFEZti'\ FREEZEP 01 TIF AP f!!'' ros ,-(gs 2v •-<:)!! • ------- / FE Ail_ F'APT:Ar?-71.fiC=5-ii OwF C 75 RE1 , -- DOC UNI.C,CKED Wi112‘!!!• OC -5C LIFE OLA,SS STORE FRONT ,REI DISPL•6.si PEFEP CONDIMENT .S1AFICN EMERALD CITY SMOOTHIE WESTFIELD SOUTHCENTER WALL SCALE 1/8'4 ir T!' i'•• NOTES: .•:.! FIELD LOCATE RELAY MODULE FOR BACK' GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE LIF ALL VAV UNITS,(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. • • , . :11! !.• • • . • 5! !!! ! • .- i•I ' •!5'. 5 1,0 CO 0• 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS z DESCRIPTION 0 tI 0 z Ix ct. 0 LL1 CLI CO 0 co 0 z • 1 I : : •!! "- • • '111 •V!'' • • ;si, ! • Copyright• 2006 by Guardian Security Systems, Inc. All Rights ReserveiV. ' 1 i w - co co 1— _1 co < Z w cc 0 (/) /2 2 w cc 0 (I) 0 5 WO-- cc co or) c‘,1 0 ‘CALE: 1 /8" = 1 DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE:5/01 /08 BACKROUND PLAN PROVIDED BY: JOB NUMBER:54503 SHEET FI -03 LJ -D 25 11351 ----- 4. A 7/,. : -14:35 uJ '1140 =a' ft- (-) F F CHAI\IC:'S P') NORTH Li 48 5] ffZ- ci_A_11 (n _J C) ri] fr: L1210 112-i 51 14251 LLI 1-12P ft PM • _ j1A.1 1,190 RECYCLING STOUGE LOADI.' DOCK CHEESECAKE F-A,C TORY : SYSTEM CALCULATIONS LL RISER - ROOM 11 -11 EMERALD CITY SMOOTHIE WESTFIELD SOUTHCENTER MALL SCALE 11321:11 EOL -S1 18.94V EX EMERALD CITY SMOOTHIE EMERALD CITY SMOOTHIE SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations FACP ADD ONS ;: Current Load: Standby: Alarm: Current Load: Standby: Alarm: 1 Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 Main System Board 1 0.03 0.03 0.030 0.030 AD2-P 1 0.0635 0.0635 0.064 0.064 SET -MC @15CD - SET -MC @30CD SET -MC @75CD SET -MC @110CD - SET-HMCC@115CD SET-HMCC@135CD SET-HMG-C@185CD ZR-MC@I5CD ZR -MC @30CD HCP Standby.,'Current Load: 2 0.064 0.098 0.175 0.233 0.048 0.318 0.445 0.064 0.350 HTR -R HTRI-D 2 0.009600 0.0096 0.021 0.042 0.001600 0.0035 If.• ._, " 0.0731 Amps 0.106 ArrIP$ 0.03 0.098 0.0015 Amps 0.38 Amps Standby Current Load: Alarm Current Load: 0.0731 0.106 Amps Amps For 24 Hours = For 5 Minutes= 1.754 0.009 Amp -hours -;„ Amp -hours 0.03 Amps For 24 Hours = 0.720 Amp -hours 25% Derating= 2.204 Amp -hours 11 I! V: • Alarm Current Load: 0.38 Amps For 5 Minutes= 25% Derating= 0.032 0.940 Amp -hours Amp -hours Total System Current Load: 2.204 Amp -hours : 1' 411 • -• Battery Pair to be Used: Total System Current Load: 0.940 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH .11 12VDC Amp -hours 7AH I r 1: 1 ;• BATTERY SIZI G CALCULATION tr. Notification Applianc Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL ..,!:;-, , 1 , ; ; 1 i - - ; Panel EMERALD CITY SMOOTHIE 1 Date: May 5, 2008 Wire Resistance -..3i4-:'-_1:-.--...--.,--..-.-.. i 1.- , i ....i 1 CURRENT TOTAL=I 594 i i CIRCUIT:iS1 1 i I ----; QTY 1 Device Type .__ ..._ __ . • , I . , , 2.46i' 1 0 ;SET -MC ©15CD 0 . SET -MC ©30CD 2 0 ; SET -MC ©75CD !SET -MC ©110CD 1 1 , , ,Alarm CLIIT321e83:830till Alarm Total Wire Size 1! ire Length 1 Voltage at EOL I Circuit Total 1 I 297i 1171 594' 01 0' o ; , i , , ,. , i , , 1 , • i . • . . , i I I 1 1 i Total Wire Resistance ( R ) , : : Total Device Load, Amps (1) ii 1 I ( WL * 2 )* (R/ft) (Total Cot Load) i ' 0.591 0 ' 1SET-HMC-C@115CD ! , Oi 1 :I IVoltage Drop ( E ) , 1.46i i , 1 0 ' ! SET-HMC-C@177CD ' 4451 01 i i (E= I * R) , 0 SET -HMC @135CD ;., 318 01 ! f i i I EOL Voltage I 1894' i i 4451 (20.4 - E) , SET -HMC @185CD . 0 1 , , , 0 i 1 1Z-MCgl 5CD i 1 , ! 1 ; , 0 . , . , 0 1 1Z-MC©30CD ' 1 2001 01 0 264' -I- SET-MC-CW@110CD i0 1 i 1 , , II i ! DEVICES= i2 i TOTAL m A= I , 1 , 594i 12 i 1 380 18.9373344 594 i , • .. i ._ ....... .. notification Appliance cuit Detail ! I : , . PROJECT: WESTFIELD SOUTHCENTER MALL, , , , Panel: EMERALD CITY SMOOTHIE :Wire Resistance 5.16 • Date' April 21, 2008 ,i, . CURRENT TOTAL= Ii 3.6 , CIRCU IT: i SPEAKER CIRCUIT f ; ; It . ; : , i QTY , Device Type Alarm Current I Alarm Total ! VVire Size i VVfr',9 Letigth Voltage at EOL i Circuit Total , , ,-- 2 170.7V1/8 f; . 361 . t ' ? ',i' . 1 ; ! I Tota I Wire Resistance ( R ) , 7.99 0i ..,... , 181 , i , • - --I 0' (‘) i.„ . i ( WL * 2 )* (R/ft) r1' i I ' ! 0 01 0 d 1 ; 0.00! i -1 r--- : - i Total Device Load, Amps (1) i I iit ; ! { 0 I 0 1 , 0 1 Il ' I ! i (Total Cct Load) , i 0 0! 01 f .'t.1 , . , 1Voltage Drop ( E 0 - 01 01 1 ,-) 1 (E= I * R) _ i $ r -ii 0 I 0 1 1 0 I ; ; : Y i , , . i -,EOL Voltage , . 20.37i . o = , 0; 0 ; i 1 ' . i 1 (20.4 - E) , 1 • 0 t :t : , i i •. 0 ,, i o 1 , o o i o i i: , t ii :. i DEVICES=2 z iTOTPL mA=1 6 3.i 12 i j• 774 ! 20.37124435 3 .6 . , 1 _., • -/•••••• 1•C• •• ••••• • • .• .- • ••,.• • ..- .••••• a, • ••••• a'. , . ,••••• . ...••• • , -, t 1 1 t 1 i I ••-- ti RISER DIAGRAM •VOLTAGE DROP CALCULATION a t) c0 0\ z 0 CD C) uJ LLJ (I) c; cn z FAX (206) 628-4990 RELEASE/REVISIONS 03 LU Ct DESCRIPTION SHOP DRAWINGS FOR AHJ co LU 0 z < < w. F- co co 7 0 04 0 <(3 ) 2 Z W CC CI) rn z Z 2 w �0(/) 0 5 FT.-•' a w 0, I u)--1 EI co (NI CC h` LLI } cc 0 . , >-- cif) } 4CALE: 1/8"=1' DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01 /08 BACKROUND PLAN PROVIDED BY: • NUMBER:54503 ,} SHEET 3- Copyright 2006 by Guardian Security Systems, Inc. All Rights ReServed FA -04 DINING B 100 jib ±15'-6" B.O. ROOF DECK DINING A COOLER & FREEZER ADJACENT TENANT N.I.C. NO CEILING ABOVE COOLER & FREEZER •w Z 0 I- 0 < H KITCHEN /PREP 101 10'-6" ank CLNG. TILE C-1 NU T-6" iink GYP. BD. SOFFIT PAINT PT -4 MALL - N.I.C. Design per NFPA 13, Ordinary Hazard All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart }i 1 — Add Viking Model VK154 Standard Response 155° Dry Pendent '/2 x 1/2 • 9 — Add Reliable Model F1 Standard Response 1550 Pendents 1/2 x 1/2 o 8 — Add Reliable Model F1 Standard Response 155° Upright 1/2 x '/2 Total = 18 REFLECTED CEILING PLAN 1/4"=1'-0" 1 • RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING HANGER DETAIL NTS ❑ Without Comments 0 As Noted in Red l' Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of. adopted standards and ordinances. The responsibility for the dequ3cy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void ti rs acceptance and will require a resubmittal of revised drawirgis for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau.__ -I 3-1 / Ev: / 1 TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address for shut - 'down or restoration approval. NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic teat t � aa'aat. C 140X1}4 • MALL KEY PLAN -1ST FLOOR K,s BROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7869 JIMMY JOHN'S 728 SOUTHCENTER MALL, SUITE 1480 TUKWILA, WA 9.8188 PAID SEP -1 2011 TUKWILA FIRE DATE:; ? 0 IE DRAWN: SCALE: I' 9 / be GENERAL LEGEND --4 —D —4 BOO BOB BOJ FOS FOW EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPLING ( UNLESS NOTED ) CAP PLUG CENTERUNE HYDRAULIC REFERENCE POINT CENTERUNE PIPE TO BOTTOM OF DECK CENTERLINE PIPE TO BOTTOM OF BEAM CENTERUNE PIPE TO BOTTOM OF JOIST FACE OF STUD FACE OF WALL FOC AFF CH R.C. E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR CEIUNG HEIGHT REDUCING COUPUNG OUTLET COUPLING WELDED OUTLET "FIT" FITTING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALSO "Gr) THREAD/"FlT" (ALSO "Fxr) ALL -THREAD ROD , - s 153tki - ;re‘i•k..ii•+,.. • 4 1 - , -'!"•*1":1'). 47'4 •!.1.• I• :V, IC ' -11 _ et;* - ' • ' -$ Wolt pg.!" tS),c - - • ' f4tVI - - at- ' ' ,....,... .V.- • ...4.'s a .,,,rf.. 4" .04 4!',. .........wr,-,,,,-- . i i's 4 • V' ti.V.4 exit:V-1'a ' ts4-• ' .4":. . . - (7, :7,-.47:i. i4o, a.i....1.1, . •,.......1,; ";,',...44, -.1i4;4-.-c,, • -1. .. - •:' 1.' 4 S 141 F ;17. 4.1 t • , . It) P. ; st.r. Vovr Aft F.4 •4 4 . 44:•iittr 5111. • II_•.etra'' CkPir- alaa, • -4 sa. Alt : 7 Ittdt Dt a EMERALD CITY SMOOTHIE TENANT SPRINKLERS 0 RELIABLE MODEL F1 -FR QUICK RESPONSE RECESSED CHROME PENDENT 1/2" 155' 1 TUKWILA FIRE DEPARTMENT Please call: 575-440Z and give thls job No. 03 S-0.9(0 and exact address for shut. . ,wn or restoration aoorovA, Ii44414M.44:44.15. •••-• i . mlne rEra Tr -.71 ra--1 Without Comments As Noted In Red Per The Attached Letter nese plans have been reviewed by The Tukwila Fire Prevention Bureau for corifomince with current city standards. Acceptance Cu errors and . omissions Which do no', of adopted standards and Tf for the adequacy of \•. ti; •Additions, dc)ier.;0,:-.;; 0: -‘4'ings atter this date Vii l void v./1 ceq&e a resubmittal of revised (1,:mi-igs for r3ubsequent approval Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: LI- By: kk,1 3-1 QTY 12 PROJECT TOTAL: 12 1 11( 2'X 4' GRID IN BACK OF HOUSE C.D (I) X uJ ALL LIGHTING IN BACK OF HOUSE TO BE CENTERED IN CEILING 'TILES STEPED SOFFIT OVER MENU BOARD WALL LAYERED CLOUD OVER SERVICE COUNTER GWB CEILING TRACK LIGHTING D1OTICE Weld stamps must be inspected before pipe is hung. Do not paint piping pri4.)r to hydrostatic test aFovL LEGEND EXISTING PIPING 1•14•41•111111 NEW PIPING J \ / 15! 1! V IA 3- 3— i 0 J t"'L-4/1 FR / il11001 11/2 11/2 10-2 4 10-2 k, <1 2-4 ,O• TENANT SPRINKLER PLAN SCALE: 1/4" = 1 '-0" GENERAL NOTES g\7 SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 - 2007 ED ALL MATERIALS SHALL BE NEW AND U.L. USTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 ALL ELECTRICAL PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS SPRINKLER HEADS TO BELOCATED IN CENTER POINT OR QUARTER POINT OF CEILING TILE TENANT SHELL SPRINKLER SYSTEM ORIGIANLLY CALCULATED FOR ORDINARY HAZARD GP 2 - .20 / 1500 SF ORDINARY HAZARD OCCUPANCY: 130 S.F. PER SPRINKLER MAX NEW PIPING TO BE 'DYNA-THREAD' THREADABLE 11-IINWALL nourish your body • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 Pfl. (425) 481-7669 Emerald City Smoothie 728 SOUTH Level 1 - Suite 1480 Tukwila, WA 90025 DATE 03/08 DRAWN: C.A. AY. DA D r 2 2008 SCALE: NOTED Tukwila Fire 1 OF 1 GENERAL LEGEND -r- -4 ROD BOB BOJ FOS FOW EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPLING ( UNLESS NOTED ) CAP PWG CENTERLINE HYDRAULIC REFERENCE POINT CENTERLINE PIPE TO BOTTOM OF DECK CENTERLINE PIPE TO BOTTOM OF BEAM CENTERLINE PIPE TO BOTTOM OF JOIST FACE OF SND FACE OF WALL FOC AFF CH R.C. 4 E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR CEILING HEIGHT REDUCING COUPUNG OUTLET COUPUNG WELDED OUTLET "FIT" FITTING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALSO "GTA) THREAD/Fr (ALSO "FxT") ALL -THREAD ROD EMERALD CITY SMOOTHIE TENANT SPRINKLERS • RELIABLE MODEL F1 -FR QUICK RESPONSE RECESSED CHROME PENDENT 1/2" 155' QTY 12 PROJECT TOTAL: 12 (PIPING LEGEND 111010 MOMMall EXISTING PIPING NEW PRIG 2'X 4' GRID IN BACK OF HOUSE • 1 ALL LIGHTING IN BACK OF HOUSE TO BE CENTERED IN CEIUNG TILES STEPED SOFFIT OVER MENU BOARD WALL LAYERED CLOUD OVER SERVICE COUNTER GWB CEILING TRACK LIGHTING .CLG. TENANT SPRINKLER PLAN SCALE: 1/4" = 1'-0" GENERAL NOTES O� D SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 - 2007 ED ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS SPRINKLER HEADS TO BELOCATED IN CENTER POINT OR QUARTER POINT OF CEILING TILE TENANT SHELL SPRINKLER SYSTEM ORIGIANLLY CALCULATED FOR ORDINARY HAZARD GP 2 - .20 / 1500 SF ORDINARY HAZARD OCCUPANCY: 130 S.F. PER SPRINKLER MAX NEW PIPING TO BE 'DYNA-THREAD' THREADABLE THINWALL 5.Z 01-P s 5u;i4 CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Emerald City Smoothie 728 SOMICENTER P AY Level 1- Suite 1480 op- 5 - 9� Tukwila, WA 25 DATE: 03/08 I DRAWN: C.A. I SCALE: NOTED 1 OF 1