HomeMy WebLinkAboutPP - 758 SOUTHCENTER MALL - JOEYS GRILL - PERMITS AND PLANS758 SOUTHCENTER MALL ASSOCIATED PERMITS 18-F-040 16-F-157 08-F-108 18-S-051 08-S-070 08-H-235 SITE LOCATION CITY OF TUICWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted far plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address:_755 Sooth C'aae1 Mal a l Tenant Name: V e,yS Property Owner's Name: / WeStile\A.YY y" (b . Mailing Address: 250D sOviii fyth Mal) la.1) ��C i% 1a , wA City State bp Suite Number: Floor. New Tenant? ❑ - Yes ❑ - No CONTACT PERSON-if there are questions about the submittal. ,/ Name: �i (� j � >1 � � Day Telephone: ' /?S ye/gate Company Name: CAT u% 'i ) »ol-e C1101 , ) Yl G Mailing Address: E-mail Address: 110 SIP 6 9. �. , 10 City State Zip Fax Number. Contractor's City of Tukwila NICE' III number: q7 . Business License number ' 0 4'95$-/7 Total number of new/relocated devices or sprinlder heads: 3 Valuation of Project (contractor's bid price): S 31 WD Scope of Work (please provide detailed information): .;)1 \n 3 nettcSl erd Y4DCa4C. _3 heads PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested m writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: ueSS/ct ,'4 /n 6 &)--) Plan Permit App.doc 8t22/14 Date: Day Telephone: ¥25 4-/F-/ • 71( j TFDFPForm 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: ' 4 1 -WO Site Address: 1 * )k-WtAtU QC.lrle--WC9 Suite Number: Floor:' J...k r) Tenant Name: 5O>( ' l QOJrr X 1,`jron 1 New Tenant? ❑ - Yes No W Property Owner's Name: eSkce\ `L% V C `CA X Mailing Address:Q OX 1-10 epic\S i008 AGJt3 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: CLU‘ -k\us Company Name: GI i,X.A.r(\Ck'i n �L.�ii` Mailing Address: V. -MS 5� A 3 Day Telephone: x41.0 W ).4(bLAS pyx-tAke UJA- City State Zip E-mail Address trJll(-a,ka i axY •wvvi Fax Number: Contractor's City of Tukwil l /� NICET III number: Business License number: U.PS-2)<-) Total number of new/relocated devices or sprinklerrheeaP-SD heads: ('')� Valuation of Project (contractor's bid price): $ �Y,�`) . Scope of Work (please provide detailed information):\\t v LC6 tV CCS C .\OssfY\ ` \ 5 \ \-‘o(1 PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: I C Print Name: (LCCA& Date: Oa I a-0 1 k Day Telephone:N o ( `o Plan Permit App.doc 8/22/14 TFD FP Form 8 n FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Joey's Grill 758 Southcenter Mall Permit No.: 08-H-235 Date: Mayl 29, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Nozzle heights above appliances to be per manufacturers installation guidelines. • Install splash guards between fryers and ranges/charbroilers. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Joey Restaurant 758 Southcenter Mall Permit No.: 18-S-051 Date: March 21, 2018 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Joey's 758 Southcenter Mall Permit No.: 08-S-070 Date: March 12, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. All references are NFPA 13, 2007 Edition. J Ea J For 5 March 2008 Michael Kellogg Smith Fire Systems 1106 54th Avenue East Tacoma, WA 98424 RE: Westfield Mall — Joey's Restaurant Tenant Improvement Independent Third Party Review — Fire Sprinkler System Dear Michael: Tuazon Engineering, PLLC 4322 NE r Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. It is noted that the sprinkler system modifications shown are to Zone T4 fed from the East Riser Room. The following was reviewed: • Fire Sprinkler Drawings — Sheets 1 and 2 dated 2/25/08 • Hydraulic Calculations dated 2/25/08 The documents were reviewed for compliance with the 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. The 2007 edition of NFPA 13 is the adopted standard in the City of Tukwila per Ordinance 2050, Section 16.42.020. The drawings and calculations currently reference the 2002 edition. 2. Ensure the dry pendent sprinklers in the cooler/freezers are of sufficient length to prevent freezing of the water filled branchline piping and the space around the barrel is sealed in accordance with 2007 NFPA 13 Para 8.4.10.1 and 8.4.10.2. 3. Hydraulic calculations indicate the coverage per sprinkler is 130 SF, which would correspond to 19.5 GPM minimum for a 0.15 GPM/SF density for Ordinary Hazard I (restaurant occupancy). However, the Summary of Sprinkler Outflows in the calculations show numerous sprinklers flowing less than 19.5 GPM. If the actual coverage area per sprinkler is being used to determine the minimum sprinkler discharge, the areas should be indicated in the calculations. Otherwise, it is recommended the calculations be revised for 19.5 GPM minimum flow per sprinkler. 4. Hydraulic calculations indicate 1-1/2 inch diameter branchlines with ID = 1.754" (Superflow piping). However, the shell/core sprinkler system by Western States Fire Protection installed schedule 40 branchlines with ID = 1.61". Assuming the shell/core branchlines are being reused, the inside diameter of all branchlines should be revised to reflect schedule 40 piping with ID = 1.61". 5. Hydraulic calculations indicate existing 4 inch diameter feedmain piping with ID = 4.316" (Superflow piping). Shell/core sprinkler system drawings and calculations indicate schedule 10 piping was installed. The calculations should be revised to indicate ID = 4.26". 6. The hydraulic calculations do not include all the riser room and underground piping to the connection to the water supply. The calculations should be revised to include the following piping, as taken from the shell/core hydraulic calculations by Western States Fire Protection (1st Level, Zone T4): a. 8" riser room piping with ID = 8.326, C=120, and 27'-9" equivalent length (includes fittings) b. 10" riser room piping with ID = 10.20, C=120, and 124'-1" equivalent length (includes fittings, except BFP) Westfield Mall — Joey's Restaurant Third Party Review — Fire Sprinkler Systems 5 March 2008 Page 2 c. 10" Wilkins 350 backflow preventer (see attached data sheet for friction loss chart) d. 10" underground piping with ID =10.400, C=140, and 246'-6" equivalent length (includes fittings) A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or eric@tuazon.com with any questions regarding this review. Respectfully, TUAZON ENGINEERING, PLLC zu.L., Eric P. Tuazon, PE Fire Protection Engineer C Corm, FIsMOS Prcre.2008 11 Smoh Fre S)abmt'Nbtlitltl JoeysY6nni08lam aMr1Er reviwvJcc GUARDIAN SECURITY Seattle • Tacoma • Poulsbo • Bellingham MFG. Joey's 758 southcenter mall tukwila, wa 98188 Fire Alarm System Submittal MODEL# DESCRIPTION [FIRE ALARM DEVICES] SIEMENS HTRI-R Interface module w/ relay SIEMENS HCP Control point module SIEMENS HFP-11 Smoke Detector SIEMENS AD2-P w/ Duct Smoke detector TSM -1 Module SIEMENS SET -MC -CW Ceiling Mount Speaker/Strobe SIEMENS ZR -MC -CW Ceiling Mount Strobe 1743 First Avenue South Seattle, WA 98134 Tel: 206.622.6545 Fax: 206.341, 9928 April,4 2008 GUARD/AN Customer LIFE AND PROPER MARINERS TEAM STORE 852 SOUTHCENTER MALL T' 'KWILA, WA 98188 Project MARINERS TEAM STORE Project # SECURITY r Y PROTECTION List of Materials Vendor Guardian Security Systems Inc 1743 1st Ave. South Seattle, WA 98134 Phone #: (206)622-6545 Fax #: (206)628-4990 Type of Equipment FIRE ALARM Date: Jan,22,09 Item Qty. Manuf. Model Description Unit Pri Total Price 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) t0) 21) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) 33) 34) 35) 36) 37) 38) 39) 40) 41) 42) 43) 44) 45) 46) 47) 48) 49) 50) Siemens PAD -3 Siemens AD2-P Siemens HTRI-D Siemens HTRI-R Siemens ZH CW,W Siemens ZR-MC-W,W Power Supply for Strobes with Standby** Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 Supervised Addressable Input Module Supervised Addressable Output Relay Module Interior Audible Horn Strobe Annunciator Interior Visual Strobe Annunciator Conduit Systems: All smoke removal and detection and control devices in an approved metallic raceway and all devices in conduit per Standard fIZDfl £flGI taction/ Code Corautting 5 March 2008 Michael Kellogg Smith Fire Systems 1106 54th Avenue East Tacoma, WA 98424 RE: Westfield Mall — Joey's Restaurant Tenant Improvement Independent Third Party Review — Fire Sprinkler System Dear Michael: Tuazon Engineering, PLLC 4322 NE 7 Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. It is noted that the sprinkler system modifications shown are to Zone T4 fed from the East Riser Room. The following was reviewed: • Fire Sprinkler Drawings — Sheets 1 and 2 dated 2/25108 • Hydraulic Calculations dated 2/25/08 The documents were reviewed for compliance with the 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. The 2007 edition of NFPA 13 is the adopted standard in the City of Tukwila per Ordinance 2050, Section 16.42.020. The drawings and calculations currently reference the 2002 edition. 2. Ensure the dry pendent sprinklers in the cooler/freezers are of sufficient length to prevent freezing of the water filled branchline piping and the space around the barrel is sealed in accordance with 2007 NFPA 13 Para 8.4.10.1 and 8.4.10.2. 3. Hydraulic calculations indicate the coverage per sprinkler is 130 SF, which would correspond to 19.5 GPM minimum for a 0.15 GPM/SF density for Ordinary Hazard I (restaurant occupancy). However, the Summary of Sprinkler Outflows in the calculations show numerous sprinklers flowing less than 19.5 GPM. If the actual coverage area per sprinkler is being used to determine the minimum sprinkler discharge, the areas should be indicated in the calculations. Otherwise, it is recommended the calculations be revised for 19.5 GPM minimum flow per sprinkler. 4. Hydraulic calculations indicate 1-1/2 inch diameter branchlines with ID = 1.754" (Superflow piping). However, the shellcore sprinkler system by Westem States Fire Protection installed schedule 40 branchlines with ID = 1.61". Assuming the shell/core branchlines are being reused, the inside diameter of all branchlines should be revised to reflect schedule 40 piping with ID = 1.61". 5. Hydraulic calculations indicate existing 4 inch diameter feedmain piping with ID = 4.316" (Superflow piping). Shell/core sprinkler system drawings and calculations indicate schedule 10 piping was installed. The calculations should be revised to indicate ID = 4.26". 6. The hydraulic calculations do not include all the riser room and underground piping to the connection to the water supply. The calculations should be revised to include the following piping, as taken from the shell/core hydraulic calculations by Western States Fire Protection (1st Level, Zone T4): a. 8" riser room piping with ID = 8.326, C=120, and 27'-9" equivalent length (includes fittings) b. 10" riser room piping with ID =10.20, C=120, and 124'-1" equivalent length (includes fittings, except BFP) 1 Westfield Mall — Joey's Restaurant Third Party Review — Fire Sprinkler Systems 5 March 2008 Page 2 c. 10" Wilkins 350 backflow preventer (see attached data sheet for friction loss chart) d. 10" underground piping with ID =10.400, C=140, and 246'-6" equivalent length (includes fittings) A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or eric(a�tuazon.com with any questions regarding this review. Respectfully, TUAZON ENGINEERING, PLLC 5,46 Eric P. Tuazon, PE Fire Protection Engineer C Carpry Flets12C05 Nods= 11 Smite Fn *Awns • Wasifid Jon/1;05 M penin *wider moon Jtc SMITH FIRE SYSTEMS, INC. JOB NO. T18023 JOEYS - SOUTHCENTER SYSTEM # 1 ENTRY CANOPY (3) DRY HSW ECOH AUXILIARY HYDRAULIC CALCULATION DESIGN DENSITY: 0.15 GPM / 375 SQ. FT. SYSTEM DEMAND AT BASE OF RISER 118.46 GPM AT 22.73 PSI SUBMITTAL SERIAL NO:2244HY1 03-12-2008 PAGE 1 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 AUXILIARY AREA: 3 DRY HSW ECOH IN FRONT CANOPY DENSITY: 0.15 OVER THE ENTIRE AREA FILENAME: TI8023EC FLOW TEST RESULTS Water Supply STATIC 140.00 PSI RESIDUAL 20.00 PSI @ 10900.00 GPM CITY PRESSURE AVAILABLE AT 368.5 GPM 139.77 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 201 202 203 39.55 38.00 40.91 38.00 38.00 38.00 11.20 11.20 11.20 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 4 OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 53 TO 203 12.47 11.51 13.34 118.46 GPM 100.00 GPM 150.00 GPM 368.46 GPM 34.19 PSI 0.00 PSI 15.19 FPS SUBMITTAL SERIAL NO:2244HY1 03-12-2008 PAGE 2 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 AUXILIARY AREA: 3 DRY HSW ECOH IN FRONT CANOPY DENSITY: 0.15 OVER THE ENTIRE AREA FILENAME: TI8023EC Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 52 202 1.049 L 7.00 C=120 PT 11.51 (202) Q 38.00 F=4E/T F 13.00 PE -1.30 DR1 T 20.00 0.4267 PF 8.53 12 52 1.754 L 66.00 C=120 PT 18.74 ( 52) Q 38.00 F=T,2E F 24.00 PE 0.00 BN1 T 90.00 0.0349 PF 3.14 PT 21.88 ( 12) 53 203 13 53 Q 40.91 Q 40.91 51 201 11 51 Q 39.55 Q 39.55 1.049 L 3.75 C=120 PT 13.34 (203) F=2E/T F 9.00 PE -1.30 DRI T 12.75 0.4891 PF 6.24 1.754 L 66.00 C=120 PT 18.28 ( 53) F=T,2E F 24.00 PE 0.00 BN1 T 90.00 0.0400 PF 3.60 PT 21.88 ( 13) 1.049 L 7.00 C=120 PT 12.47 (201) F=2E/T F 9.00 PE -1.30 DR1 T 16.00 0.4594 PF 7.35 1.754 L 66.00 C=120 PT 18.52 ( 51) F=T,2E F 24.00 PE 0.00 BN1 T 90.00 0.0376 PF 3.38 PT 21.90 ( 11) 12 13 4.260 L 10.00 C=120 PT 21.88 ( 13) Q 40.91 F=0 F 0.00 PE 0.00 FM2 T 10.00 0.0005 PF 0.01 11 12DQ 38.00 4.260 L 9.42 C=120 PT 21.89 ( 12) Q 78.91 F=0 F 0.00 PE 0.00 FM2 T 9.42 0.0018 PF 0.02 20 11DQ 39.55 4.260 L 24.00 C=120 PT 21.91 ( 11) Q 118.46 F=T F 26.00 PE 0.00 FM2 T 50.00 0.0038 PF 0.19 10 20 4.260 L 57.00 C=120 PT 22.10 ( 20) Q 118.46 F=4E,EE F 57.00 PE 0.20 FM1 T 114.00 0.0038 PF 0.43 4 10 4.260 L 11.50 C=120 PT 22.73 ( 10) Q 118.46 F=T,BFY,CV F 65.00 PE 4.98 FR1 T 76.50 0.0038 PF 0.29 COMMENT: 100 GPM ADDED FOR INSIDE HOSE ALLOWANCE SUBMITTAL SERIAL NO:2244HY1 03-12-2008 PAGE 3 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 AUXILIARY AREA: 3 DRY HSW ECOH IN FRONT CANOPY DENSITY: 0.15 OVER THE ENTIRE AREA FILENAME: TI8023EC Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 3 4DQ 100.00 8.249 L 27.75 C=120 PT 28.00 ( 4) Q 218.46 F=0 F 0.00 PE 0.00 FR2 T 27.75 0.0005 PF 0.01 2 3 10.200 L 124.08 C=120 PT 28.01 ( 3) Q 218.46 F=0 F 0.00 PE 0.00 FR1 T 124.08 0.0002 PF 0.02 1 2 10.000 L 0.01 C=120 PT 28.03 ( 2) Q 218.46 F=DD1 F 0.00 PE 0.00 MA1 T 0.01 0.0002 PF 0.00 10" WILKINS 350DA 6.12 0 1 10.275 L 246.50 C=140 PT 34.15 ( 1) Q 218.46 F=0 F 0.00 PE 0.00 UN1 T 246.50 0.0001 PF 0.02 PT 34.17 ( 0) SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East • Tacoma, Washington 98424 (253) 926-1880 • FAX (253) 926-2350 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME JOEYS - SOUTHCENTER JOB NO. TI8023 DATE 3/6/08 ADDRESS t5-(--633' SOUTHCENTER PKWY BY M. KELLOGG TUKWILA, WASHINGTON 98188 SYSTEM DESIGNATION: WET SYSTEM 1 HAZARD DESCRIPTION: RESTUARANT HAZARD CLASS PER NFPA 13 : (2007) ORDINARY HAZARD GROUP 1 SPECIFIC RULING: RULING MADE BY: OF DENSITY: 0.15 GPM OVER THE MOST HYDRAULICALLY REMOTE 1500 SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: INSIDE HOSE 100 GPM OUTSIDE HOSE IN -RACK SPRINKLER DEMAND SYSTEM TYPE: WET "C" FACTOR OVERHEAD : 120 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: SPRINKLER MANUFACTURER: RELIABLE MODEL: K -FACTOR: 150 GPM GPM ADDED AT: NODE 4 NODE 0 TOTAL NUMBER OF SPRINKLERS THIS SYSTEM "C" FACTOR UNDERGROUND : 140 130 SQUARE FEET G4A TEMPERATURE: 155 ° F 5.6 ORIFICE SIZE: 1/2" 115 WATER SUPPLY: STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM ELEVATION OF TEST: SITE DATE OF TEST: DATA PROVIDED BY: LOCATION OF TEST: SITE WSFP PLANS OF EXISTING SHELL SYSTEM BASE OF RISER DEMAND 478.55 GPM REQUIRED AT 46.15 PSI (INCLUDING 100 GPM FOR HOSE STREAMS) SUMMARY 628.55 GPM REQUIRED AT 51.69 PSI AT CONNECTION TO CITY MAIN (INCLUDING 250 GPM FOR TOTAL HOSE STREAMS) • EYS SOUTH BRLICANIMAgiffiE z cc m 0 o O D 0) z 0 z a C. • UTHEAST CORNER OF RE TA : _ 1 t ii 1!a �, N Iii11111111111111111111111 ::�HH iNN_■■_■_■■iaii -------------u~iU u~i W W WO Z aO= 2 O � 11111111111 G o 111111 IIIIIIIIIIIIIHIHHIIIIIIIIHHHIIIIHIIIUIIIIIIHIIHIIHI a0 D g 0 1 o• w IHI1llhIOIHOHHHHOHiftHIKh1IIifflHffHin 2 • II■ ■■■■■■■■■■■■■■■■N■■■■■■■■■H■■■■■■■■/■■■■■■■■■■■■■■■■■■■■H� cd 0 N N Z `� v II. IIOIIIIIl!I1IIIIH IUII!flhIIIIIAhhIIAhIIIHhIlI N II■ ■■ ■■ ■ III�■N ■■■ ■■■H■■■■■iiiuii1 -, 1111-111 - I VIII ill 11 l IIIYII ul IIINlllblllllhIl 1 I1IIIlluIl1Hh 1 IIIUII i IIHLI HIII lIIUIIlII■IIIIIIi1111II11HIQ1IIII!IWI i /1IHIII//ii11i 11IHilHi Norm iiihiilHllHiilHiil1Hll!Hillhill ilii 1 lH II 1 1 ! i11H1111111 111 IIHIIIHIIIHII 1111111111111111 11111111 II1llII1llUlIlUlI11 i1HiliHilliH 1 1 III :I VIII IMO MEM HHHHIIIIHIIIIIIIIHIIIHHHIHII 1111111111111111 111111 IIAIIINi111111111111111111Ih1 IHIHIIIIIIIIHIIIIi11111HH IuhIIohIrIII111 IHIHIIIIIOIIIKIIIIIHUII uIUhIuuI[LI 11111 � Q , Illlllllli n :. 0 1 a. v0__1›. , II- uR. II uuuuuuiniHiiiF�iJIIiii■u uu.nuu.uuh■Nu. N co _ w J j ��j �f lF1LI11hllh11I11lKh1Il co cc LL < a 111± j f!}■ ■ ■■■ ■■■ _■ ■ ■■■ ■■ ■■N■■■ �►`\■■■■N■■■■■■■■■■ •ililiilm o01-�l IH 11111114111110 lllllillililii 11111 r llN!!!lhlhIHl 11111! lli1YHlhlii!®i 11111 l!illhiilhIil N■■■■■/■■ ■■■■■■ ■ ■H■■ ■ ■ ■■■■■■■■.■/■■■■H■■H■■■■N■■■■■■■■\`\■■NH■■■■/■ iiiiiiiiliiiiii HiihHi 1110 iliihIIHhIHHHi111PMEOhHihIIIOUIIMii 4 IIIIIhhhilhhhII IIIIIhlIilHihhhN111111111111lH111t1i11111111H1HII11illlllllillI1b 11111,,1Ii1111l1., o IIA1 1A1 1111111:-1 - 11�l1 1111. ��. _ �, ,., Q- a ;141-1-1-#911Z2 ISd NI 31:if1SS3Hd o, NX 0 z w 2 J 0 CO SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 1 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 FLOW TEST RESULTS Water Supply STATIC 140.00 PSI RESIDUAL 20.00 PSI @ 10900.00 GPM CITY PRESSURE AVAILABLE AT 628.6 GPM 139.39 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 101 26.58 19.50 5.60 22.53 102 26.51 19.50 5.60 22.40 103 21.99 19.50 5.60 15.42 104 20.81 19.50 5.60 13.81 105 20.05 19.50 5.60 12.81 106 19.73 19.50 5.60 12.41 107 19.58 19.50 5.60 12.22 108 19.50 19.50 5.60 12.13 109 23.04 19.50 5.60 16.92 110 22.18 19.50 5.60 15.68 111 21.64 19.50 5.60 14.93 112 21.34 19.50 5.60 14.52 113 21.25 19.50 5.60 14.41 114 24.18 19.50 5.60 18.64 115 23.63 19.50 5.60 17.80 116 23.31 19.50 5.60 17.33 117 23.25 19.50 5.60 17.24 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 4 OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 22 TO 33 378.55 GPM 100.00 GPM 150.00 GPM 628.55 GPM 51.69 PSI 0.00 PSI 16.15 FPS SUBMITTAL SERIAL N0:2244HY1 03-06-2008 PAGE 2 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 Location Flow Pipe Fittings Equiv Friction, Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 38 108 1.049 L 31.00 C=120 PT 12.13 (108) Q 19.50 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1242 PF 4.72 37 38 1.754 L 13.00 C=120 PT 15.55 ( 38) Q 19.50 F=0 F 0.00 PE 0.00 BN1 T 13.00 0.0102 PF 0.13 PT 15.68 ( 37) 47 117 1.049 L 31.00 C=120 PT 17.24 (117) Q 23.25 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1720 PF 6.54 46 47 1.754 L 8.50 C=120 PT 22.48 ( 47) Q 23.25 F=0 F 0.00 PE 0.00 BN1 T 8.50 0.0141 PF 0.12 PT 22.60 ( 46) 46 116 1.049 L 31.00 C=120 PT 17.33 (116) Q 23.31 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1728 PF 6.57 45 46DQ 23.25 1.754 L 12.50 C=120 PT 22.60 ( 46) Q 46.56 F=0 F 0.00 PE 0.00 BN1 T 12.50 0.0508 PF 0.63 PT 23.23 ( 45) 45 115 1.049 L 31.00 C=120 PT 17.80 (115) Q 23.63 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1771 PF 6.73 44 45DQ 46.56 1.754 L 10.50 C=120 PT 23.23 ( 45) Q 70.19 F=0 F 0.00 PE 0.00 BN1 T 10.50 0.1086 PF 1.14 PT 24.37 ( 44) 44 114 1.049 L 31.00 C=120 PT 18.64 (114) Q 24.18 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1849 PF 7.03 24 44DQ 70.19 1.754 Q 94.37 BN1 L 15.67 C=120 PT 24.37 ( 44) F=T,2E F 24.00 PE 0.00 T 39.67 0.1878 PF 7.45 SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 3 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 23 24 4.260 L 10.00 C=120 PT 31.82 ( 24) Q 94.37 F=0 F 0.00 PE 0.00 NC1 T 10.00 0.0025 PF 0.02 PT 31.84 ( 23) 43 113 1.049 L 31.00 C=120 PT 14.41 (113) Q 21.25 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1456 PF 5.53 42 43 1.754 L 13.00 C=120 PT 18.64 ( 43) Q 21.25 F=0 F 0.00 PE 0.00 BN1 T 13.00 0.0119 PF 0.15 PT 18.79 ( 42) 42 112 1.049 L 31.00 C=120 PT 14.52 (112) Q 21.34 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1467 PF 5.57 41 42DQ 21.25 1.754 L 13.00 C=120 PT 18.79 ( 42) Q 42.59 F=0 F 0.00 PE 0.00 BN1 T 13.00 0.0431 PF 0.56 PT 19.35 ( 41) 41 111 1.049 L 31.00 C=120 PT 14.93 (111) Q 21.64 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1506 PF 5.72 40 41DQ 42.59 1.754 L 11.00 C=120 PT 19.35 ( 41) Q 64.23 F=0 F 0.00 PE 0.00 BN1 T 11.00 0.0922 PF 1.01 PT 20.36 ( 40) 40 110 1.049 L 31.00 C=120 PT 15.68 (110) Q 22.18 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1575 PF 5.98 39 40DQ 64.23 1.754 L 10.50 C=120 PT 20.36 ( 40) Q 86.41 F=0 F 0.00 PE 0.00 BN1 T 10.50 0.1595 PF 1.67 PT 22.03 ( 39) 39 109 1.049 L 31.00 C=120 PT 16.92 (109) Q 23.04 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1690 PF 6.42 SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 4 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 23 39DQ 86.41 1.754 L 15.67 C=120 PT 22.04 ( 39) Q 109.45 F=T,2E F 24.00 PE 0.00 BN1 T 39.67 0.2470 PF 9.80 22 23DQ 94.37 4.260 L 7.92 C=120 PT 31.84 ( 23) Q 203.82 F=0 F 0.00 PE 0.00 NC1 T 7.92 0.0104 PF 0.08 PT 31.92 ( 22) 37 107 1.049 L 31.00 C=120 PT 12.22 (107) Q 19.58 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1251 PF 4.75 36 37DQ 19.50 1.754 L 7.00 C=120 PT 15.67 ( 37) Q 39.08 F=0 F 0.00 PE 0.00 BN1 T 7.00 0.0368 PF 0.26 PT 15.93 ( 36) 36 106 1.049 L 31.00 C=120 PT 12.41 (106) Q 19.73 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1269 PF 4.82 35 36DQ 39.08 1.754 L 7.00 C=120 PT 15.93 ( 36) Q 58.81 F=0 F 0.00 PE 0.00 BN1 T 7.00 0.0783 PF 0.55 PT 16.48 ( 35) 35 105 1.049 L 31.00 C=120 PT 12.81 (105) Q 20.05 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1307 PF 4.97 34 35DQ 58.81 1.754 L 10.00 C=120 PT 16.48 ( 35) Q 78.85 F=0 F 0.00 PE 0.00 BN1 T 10.00 0.1347 PF 1.35 PT 17.83 ( 34) 34 104 1.049 L 31.00 C=120 PT 13.81 (104) Q 20.81 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1400 PF 5.32 33 34DQ 78.85 1.754 L 10.50 C=120 PT 17.83 ( 34) Q 99.66 F=0 F 0.00 PE 0.00 BN1 T 10.50 0.2077 PF 2.18 PT 20.01 ( 33) SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 5 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 33 103 1.049 L 31.00 C=120 PT 15.42 (103) Q 21.99 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1551 PF 5.89 22 33DQ 99.66 1.754 L 15.67 C=120 PT 20.01 ( 33) Q 121.65 F=T,2E F 24.00 PE 0.00 BN1 T 39.67 0.3004 PF 11.92 21 22DQ 203.82 4.260 L 10.00 C=120 PT 31.93 ( 22) Q 325.47 F=0 F 0.00 PE 0.00 NC1 T 10.00 0.0246 PF 0.25 PT 32.18 ( 21) 32 102 1.049 L 31.00 C=120 PT 22.40 (102) Q 26.51 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.2191 PF 8.33 31 32 1.754 L 9.50 C=120 PT 29.43 ( 32) Q 26.51 F=0 F 0.00 PE 0.00 BN1 T 9.50 0.0179 PF 0.17 PT 29.60 ( 31) 31 101 1.049 L 31.00 C=120 PT 22.53 (101) Q 26.58 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.2203 PF 8.37 21 31DQ 26.51 1.754 L 15.67 C=120 PT 29.60 ( 31) Q 53.09 F=T,2E F 24.00 PE 0.00 BN1 T 39.67 0.0648 PF 2.57 20 21DQ 325.47 4.260 L 53.42 C=120 PT 32.17 ( 21) Q 378.55 F=T F 26.00 PE 0.00 FM2 T 79.42 0.0326 PF 2.59 10 20 4.260 L 57.00 C=120 PT 34.76 ( 20) Q 378.55 F=4E,EE F 57.00 PE 0.20 FM1 T 114.00 0.0326 PF 3.72 4 10 4.260 L 11.50 C=120 PT 38.68 ( 10) Q 378.55 F=T,BFY,CV F 65.00 PE 4.98 FR1 T 76.50 0.0326 PF 2.49 COMMENT: 100 GPM ADDED FOR INSIDE HOSE ALLOWANCE SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 6 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 3 4DQ 100.00 8.249 L 27.75 C=120 PT 46.15 ( 4) Q 478.55 F=0 F 0.00 PE 0.00 FR2 T 27.75 0.0020 PF 0.06 2 3 10.200 L 124.08 C=120 PT 46.21 ( 3) Q 478.55 F=0 F 0.00 PE 0.00 FR1 T 124.08 0.0007 PF 0.09 1 2 10.000 L 0.01 C=120 PT 46.30 ( 2) Q 478.55 F=DD1 F 0.00 PE 0.00 MA1 T 0.01 0.0008 PF 0.00 10" WILKINS 350DA 5.27 0 1 10.275 Q 478.55 UN1 L 246.50 C=140 PT 51.57 ( 1) F=0 F 0.00 PE 0.00 T 246.50 0.0005 PF 0.12 PT 51.69 ( 0) I I FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUM3ESHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FI ALARM SYSTEM PJ,N c -P ED SHEET INDEX - Without Comments p As Not -F.%6 in Red p Pea The Attached Letter These plans ha''t_ be,!.: :; ': aed 'hv The Tukwila Fire Pre'v'ention Buren: '. rare with current City standards. Acr_ ,, . 2 . "j = s� i. ors and omissions whicil ' } :.. ; { . ..' )ns of adopted _andards anu , ,�.t :,:,r;.:. ,;1'`t:� for the quacy of aeric ; ".a :iewlgi ler. :alae ......._.. ... . ;'?tuitions, ir3 winqS after this date MI �"W __ L''? 'tr �eotar. l� require a resubmittal e . , '. ` . <a approval. Final acceptaliCe s : a+. r.,leci. tt)11e test and inspection by The Tukwila Fire~ Prevention Bureau. ^^ Date: -3 By. S I WI NOn A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testino SCHEDULE A\D CO\SUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPLJFPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKED V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END TUKWILA FIRE DEPART HENT Please calls 206-575-4407 and give this Fire Permit No. 1(P -r IS -7 and exact address for shut- down or rest+.ortien approval. FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSDCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT EE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVCE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDJIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SI -ALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MININUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX EX EX 1 EX EX EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS EX REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD -3 -ENOL 66" A.F.F. TO TOP ®DEX DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM EX DUCT DETECTOR TEST SWITCH (EXISTING) TSM- 1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE EX WITH RELAY (EXISTING) HTRI-R SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM -4 N STROBE (NEW) ZR -MC -CW SIEMENS 4S BOX CEILING FIRE ALARM EX STROBE (EXISTING) ZH-MC-CW SIEMENS 4S BOX CEILING 3EX FIRE ALARM HORN STROBE (EXISTING) ZH-MC-CW SIEMENS 4S BOX CEILING 8EX FIRE ALARM HORN STROBE (EXISTING) ZH-MC-W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS i.275sf BOXLUNCH SPACE #652 / STORE #4530 j macys - LEVELS _50.407sf as3 x0� IvEreaM, vwP,ESS Ascxouy.= • 1 • RR FEN E4 F i tr� o ° II <. w [1.1:.171=, r1 SEARS TR A`3wra L:UARA.Wa 0 R-rH..vr PATH 'cJ Pam JCPenney PAID ``ne12016 TUKWILA FIRE 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 2 0 DESCRIPTION SHOP DRAWINGS DATE M N. 0 <aaa< 0 co Lc) 1 cc 0 L.. 0j CO 0 co T ~ NC) "7" z 'Qom° G- w< cLz D (DI CO aW� CCW LL U II- 0 • imam 0 z 111 0) (11) �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:07/13/1 6 BACKROUND PLAN PROVIDED BY: .0B NUMBER:17025-1} SHEET WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All. Rights Reserved FA -01 } THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ —7 DEDICATED EMERGENCY 111 TUBE OUTLET--\ SAMPLING TUBE INLET— SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL N01E FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. *CONTACT RARNGS 4.014 0 125VAC 4.0A 0 30VDC MINsHoRWIANGB TO NEXT ADDRESSABLE (+ DEVICE STOP W LAST DEVICE FROM XLS CONTROL PANEL (+ DR PREVIOUS ADDRESSABLE DEVICE — O O � GROU1 1-11 ar u 1 4 HTRI—R 0 O O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE LJLJLi ORD N L O X O PAD -3 0 00 INPUT INPUT TROUBLE MCI NAC2 NAC NAC4 AUX + – 1 2+ 2– 2 NC C NO + – + – + – + – + – _Iuuuu 0 3.6k EOL 0 2 0 0 I O let (—) (+) , NAC 4 CIRCUIT NAC 3 CIRCUIT NAC 2 CIRCUIT CEILIN TILE oO 00 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (—) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE 1+ O (+) FROM XLS CONTROL PANEL OR i+ PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH -- h GROUND B 0 -o Li) HTRI—R OSTATUS LED CO 0 N.O. 0 COM m N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O MUSIC u v HORN/STROBE OR STROBE ONLY 0 HORN/STROBE OR STROBE ONLY 1 HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL L} -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATINc TEMPERATIIRE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —. FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > DATA IN (+) > TO NEXT DEVICE OR END OF LINE DEVICE IS LISTED FOR AIR VOLOCIIY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (—) > TO NEXT 1 1 . ADDRESSABLE DEVICE (+) SMOKE DETECTOR WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE TB1 ®® NO COM NC 0 ? TO FAN SHUTDOWN 470 SWITCH + INPUT LED TSM -1 TONEXT ADDRESSABLE DEVICE 0 a NO® COM B HTRI-R NC B TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX TO NEXT DEVICE JUNCTION BOX MOUNTED AGAINS CEILING SUPPORT SMOKE DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS (REV. BY: C0 m 0 DESCRIPTION SHOP DRAWINGS DATE L0 c M , 0 2<<<<< U z J O 0 cc NG AND MOUTN CC J U /;CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07/ 13/ 1 6 BACKROUND PLAN PROVIDED BY: \ OB NUMBER:17025-1} SHEET FA -02 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved \, A B C D E F G H I J K FIRE ALARM BOOSTER Project: BOXLUNCH Panel: EXISTING PAD -3 BOOSTER Date: July 13, 2016 Module/Device POWER POWER Qty SUPPLY SUPPLY Standby (mA) BATTERY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 30 30 0 30 30 0 TOTAL FIRE ALARM POWER SUPPLY 30 30 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 622 Total(A)= 30 Total(B)= 652 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 30 652 Total current ratings converted to amperes (line D x .001) 0.03 0.652 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.72 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.0543116 Add lines G and I Total Standby and Alarm AH 0.7743116 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.92917392 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: BOXLUNCH Panel: EXISTING PAD -3 BOOSTER POWER SUPPLY Date: July 13, 2016 Wire Resistance 2.58 CURRENT TOTAL= 622.00 ZH-MC-CW @l5cd 2 ZH-MC-CW @30cd 1 /J -1 -MC -CW @75cd ZH-MC-CW @95cd 2 ZR -MC -CW @l5cd ZR -MC -CW @30cd DEVICES 5 87 131 222 292 69 111 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 0 262 222 0 138 622 14 289 23.07 (WL*2)*(R/ft) (Total Cct Load) (E= I * R) 24 - E) 622 1.49 0.62 0.93 23.07 CALCULATIONS TO NEAREST EXISTING POWER SUPPLY (TENANT J -BOX) TO NEAREST EXISTING DATA LOOP J S1-1 51-2 30cd 15cd SINGLE LINE DIAGRAM EX D D,I_y HT -R 214 I TSM EX EX S1-3 S1-4 S1-5 15cd 75cd 30cd 004. rr) co 0\ ASH INGTON 1743 IST AVE. SO., SEATTLE, FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE (0 M N. 0 0 0 coLU z w cc z�c UJ 0 03 T HNA = 0 *z 0 < (1) o Z w Q_z D cn = J JQ x2< z Ocr 2 O mQWg 1= ZY _ w� LL 01- D 2 J 0 .� M `-r+ co W I -- y— /\ No -Mo DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07/13/16 BACKROUND PLAN PROVIDED BY: \0B NUMBER:17025-1} C SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved \ J TO TENANT JUNCTION BOX A AD,J.A.CENT -•:E\IANT S1-2 15cd D TO TENANT JUNCTION BOX 4 EX S1-1 30cd EX • FXISTINc":; STOC-r<ROOM N S1-3 15cd ,/// /,/ • // C s, / AL\JAC ENT TENANT s ALtAREA S1-4 75cd EX EX '.;17 CASH/ \V PA D _7„/7T , / / / / 8E,Aw_X EOL S1 S1-5 30cd Lij MAL! CORRIDOR FIRE ALARM SYSTEM PLAN Fri COMMON 2 \, 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 1REV. BY: I 0 0 DESCRIPTION SHOP DRAWINGS DATE (9 Z r, 0 2 <<<<< Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved L1.1 CC LL ‘CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07/13/16 BACKROUND PLAN PROVIDED BY: \0B NUMBER:17025-1j 1. SHEET '\ FA -04 ,/ I (7 '7= H D 33I \ \ , A / .) SOUTHCENTER MALL \ \ L 31 I IJ 1 D HANGER LEGEND TARGET SITE PLAN 0 50 120 150 200 250 = 192 SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND CCE, TE • Wthout Comments O As Noted In Red Per The Attached Letter !nese plans have been revinfed by The Tukwila Fire Prevention Bureau for cot', cir-friai-,ce with current city standards. Acceptance -„!!_ib1 to errors and omissions whin d3 r!Cli..31..iti'ic:rize violations of adopted standards and Thzt. r,:!.3ponfiiti4;lty for the adequacy of cie!,-3n with the designer. Additions, deletions ari,:-!visions to these drawings atter this date will void thi.s.accEptance Rnd will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. [Date: 3 -0- -og By: k\-11 • - ,FSYSINITILATOcer l'fittWILA FIRE DEPARTMENT Please call: 575-440Z and give this job No. OR -S -07D and exact address for shut, down or restoration approval, REVISIONS SYM 1,1ANUFAGRI59I 5.114. TYPE MODE_ 1•41.1 Mei 0•4114.• 11146.0 1131• .70 0.0•17117 TOTAL THIS SHEET .30 805 BCD 130.1 BCP ROT CIS FO POW ORM 585 UFO MOLE FICSHED H.00R SOROS OF BEAN BOTTOM OF DEM BOTTOM CF JOST 0001018 01' IRAN sonvoi OF GOSS CUT 1083310 FELE/ ORDER ASCE FACE CIF WALL ClUISCE FN:E 08 8383). 60*31770 SPRiNCLERS UN.ESS FMB, OTHERWSE BOO 0 13 CENTERLINE OF PIPE TO REFEREhCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY MAX; LETTER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRAE LETTER INDICATES -TYPE HANGER LOCATION ELEVATION ABOVE RutEHENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO. DATE BY REASON FOR REVISION C _PS/ CONTRACT WITH GENERAL NOTES 1. ALL GROOVED COUPLINGS TO BE RIGID UNLESS NOTED (UI) WHICH ARE FLEXIBLE. 2. ALL STEEL PIPE TO BE AS FOLLOWS: STEEL PIPE ASTM A - 795 OR BETTER PIPE SUM SCHEDULE WALL THICIGNESS INTERNAL DIAMETER END PREP TYPES ALLOWED BELOW OF HAMA /FFE CAP1.11` IA ONCOG 1 40 0.133 1.049 THREADED, CUT GROOVED, ROLL GROOVED, PLAIN ENG POLISHED 2.053 0.044 1 1/4 SUP05-FID 0.059 1.542 mu. GRSOVED, POLISHED, PLAIN END (FOR SUIT WELDING) 1.817 0.097 1 12 SUPER-FLO 0.074 1.752 ROLL GROOVED. POUSHED, PLAIN 0.0 ( Fr* WIT WELDING) 2.448 0.125 2 SUPER -FW 0.074 2.227 ROLL GROOVED. POUSHED, PLAIN ENO (FOR 5117 881.0581) 3.456 0.202 2 1/2 SUPER -FW 0.074 2.727 Rom. GROOVED. PUIIN 8115 (FOR ENT YIELDING) 4.734 0.303 3 SUPER-FLO 0.074 3352 ROLL GROOVED, PIAIN END (FOR BUTT VASLING) 6.526 0.458 4 SUPEFI-FW 0.074 4.352 ROLL GFOOVED, PLAIN ENO (FOR Km sums) 9.927 0.773 5 10 0.134 5295 ROLL GROOVED. PLAN 0830 (55 COTT 'BELDING) 17.303 1.144 8 ..., 0.134 6.357 ROLL GROOVED, PLAIN END (FOR WIT VIELLING) 23.020 1.849 8 .., 0.188 8249 FOU. GROOVED, P3415 0830 (FOR BUTT ISELLIN3) 40.083 2.78 .. WALL THICKNESS PER NFPA #13 SCOPE OF WORK SMITH FIRE SYSTEMS (SFS) WILL START AT THE EXISTING 4MAIN OF THE WET PPE FIRE SPRINKLER SYSTEM AND ADD BRANCHUNES MID SPRINKLERS TO ACCOMMODATE THE NEW TENANT IMPROVEMENT. CLARIFICATIONS - ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINF_D AT A M942AUPA 40° F, BY OTHERS, TO PREVENT FREEZING. - SPRINKLERS ARE NOT NECESSARILY CENTERED IN THE CEILING TILE EXCLUSIONS - ALARM WORK OR ELECTRICAL V,IR*IG. - PROTECTION 1s1 NON-COMBUSTIBLE VOID SPACE - PROTECTION UNDER RAISED FWOR. - PROTECTION OF KITCHEN 50009 /781 E<HAUST DUCTS. DESIGN CRITERIA - PER NFPA *13 (2007 EDMON)N4D THE cny OF TUKWILA DESIGN DENSITY: 0.15 GPM / 1500 SQ. FT. PIPING / FITTING LEGEND Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 or email fireinsprequestPci.tukwila.wa.us to schedule your inspections a minimum of 48 hours in 'advance of the date you want an inspection. NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic test approval. J R A13130TT CONSTRUCTION 3512 AIRPORT WAY SOUTH SEATTLE, WASHINGTON 98134-2135 PROJECT MANAGER: JED BICKFORD PHONE : (206) 467-8500 FAX: (206) 447-1885 SUPERINTENDENT : WAYNE JACKSON PHONE : (206) 854-3853 FAX: E0STING PIPING NEW PIPING 3. ,....*404-4•41.14270', FIL 3701 5»1 PA)oi 08 1.67/5:>0 7 .51 irk SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 98424 CONTR. REG. NO. SMITHFS138:11- Bus: ( 253 ) 928 - 1880 FAX (253) 926-2350 JOEYS - SOUTHCENTER --enSOUTHCENTER PKWY /Ode TUKWILA, WASHINGTON 98188 DESIGNER DATE SHEET JOB NO. M. KELLOGG 02/25/08 1 OF 2 T18023 W18 x35 .4 1 1' 10-0 rI I- EXISTING 4• MAIN O 1 INSTALLED BY OTHERS g 24 I O z 3 7-11' 247 W 24x82 O W24 x55 .4 I I9'4i / 9'3' 170' 9'-0' / 2.0 / 5,10' x/ (I 0 EXISTING 4'MAIN 1 ' i- INSTALLED BYOIH2?S I W 24 x62 10-0' ROLL EXISTING 4• MAN INSTALLED BYOTTERS SO THAT OUTLETS ARE ON BOTTOM .4 W24 x 52 f_/:K K -W12 x14 TOT W24 x78 = 10T TOT KITCHEN HOOD N.K.S. W14x28 W 16 x 31 y II 114' .1.5 22T W12x14 HYDRAULICALLY MOST DEMANDING AREA: SYS# 1 DENSITY: 0.15 GPM OVER 1500 SQUARE FEET SYSTEM DEMAND AT BOO: 478.55 GPM AT 46.15 PSI ( INCLUDING 100 GPM FOR INSIDE HOSE STREAMS ) /"" W 12 x14 W 14026 W18x31 48T W18x26 .4? DUSTING 8' BACKFIDW INSTALLED BY OTHERS EXISTING 4• RISER INSTALLED BYOTHERS f-- EXISTING 6' HEADER INSTALLED BY OTHERS 18Kw/: W18 x28 1 HOUR MECH. SHAFT ABOVE NAS. 43} * % l0 11 ,l1 10E u *11 W24 x55 W78x28 W 14x22 HANGER LEGEND SPRINKLER LEGEND N 11I OVERHEAD SPRINKLER PLAN O 4 8 SCALE 114'=1'-0' ABBREVIATIONS SYMBOL LEGEND FITTER / LISTER NOTES 1. ATTACH NEW BRANCHLINES TO CAPPED EXISTING 1.5' SHAPE NIPPLES. 2. SEND 1' PLUGS FOR OUTLETS ON BRANCHUNES. 3. FITTER TO VERIFY CEILINGS PRIOR TO ORDERING DROPS. REVISIONS SYM WVYUFACTURER 5.1N. TYPE MODEL SEE HANGER DETALS THIS SHEET • ®1k 4 RELIABLE RELIABLE RELIABLE RELIABLE TYCO 83615 SSP FIFR 85415 CONC PEND G4A 85415 ,CONC PEND 85714 DRY PEND TY5339 DRYHSW G4A F3QR DS -3 (ECOH) CHR BRZ 8112 CHR CHR CHR CHR BLACK CHR CHR 1/2 1/2' 1/2' 1/L 11.2 K 1/2' 1/2 1/2 155' 165° 155' 288° 155° 32 81 13 8 3 TOTAL THIS SHAT 115 Al* NCO 8® B OP BOT FO 215 FON CRYN NAS VO MOMS F1i94311 R001 BOTTOM OF BEAM 801126 OF 0E0C B OTTOM 2F x1sT 801126 CF PURA BORON OF TMS4 CUr TO 910 FED MEE RACE CF AYNL 00 AUT FACE OF WA AU10LL NO .E MESS NOTED05030DEMME 12 BOD 0 —H -- CENTERLINE OF PIPE TO REFERENCED STRUCTURE N INCHES 2 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCE) POINT N FEET AND INCHES HYDRAULIC CALCULATION NGDE FL.E CELE COUPUNG RIGID COUPLING NO. DATE BY REASON FOR REVISION CONTRACT Wf 11 J R ABBOTT CONSTRUCTION 3512 AIRPORT WAY SOUTH SEATTLE, WASHINGTON 98134-2135 PROJECT MANAGER : JED BICK FORD PHONE: (206) 467.8500 FAX: (206) 447-1885 SUPERINTENDENT : WAYNE JACKSON PHONE: (206) 854.3853 FAX: HANGER DETAIL T ( r CONCRETESTEELPANDECK FLOOR ON j 36' x 33/4' KWIK BOLT -' ^ 318' RO0 COUPLNG (2-5/8' MIN. Ewe)) 3I8'x (2-10) ATR HANGER RING HANGER DETAIL 'K HIL7T 3/8' HDI DROP N ANCHOR 310' x 3-3/4' KWIK BOLT (2-58' MIN. EMBED) 318' RDD COUPLING 318'5 (2-10) ATR (2) HANGER RINGS WITH R) TOLCO FIG. 25 SURGE RESTRAINERS TOLCO FIG. 75 SWIVEL. ATTACHMENT - 3/70 (4-0) RESTRAINT ROD HANGER DETAIL 'KR' 2ND FLOOR (Ir? BRANCHI'E DROP 1'x (ROI SCH-40, MIT WITH 90' ELBOW III 1 1' ELBOW ••::•T: (1-0 ABOVE FINISHED CELLNG) SPRNIOBI FLEX DROP DETAIL 114 (4-3) SCHF40, TXT 1 I� FOAM RUBBER INSULATION FOAM -0 -RM 1' THREADED / TEE AND PWG DRY PENDENT- " A=18' COOLER CELNG DRY PENDENT DETAIL Chi 2RCATE OF DI W ETENCY /UAW KEY Pur 5F5 co 1- z 0 Lll o 0 0 SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 96424 CONTR REG. NO. SMITHFS1380T Bus: ( 253) 926-1880 FAX: ( 253) 828-2350 JOEYS - SOUTHCENTER 633 SOUTHCENTER PKWY TUKWILA, WASHINGTON 98188 DESIGNER 1 DATE M. KELLOGG 1 02/25/08 SHEET 2 OF 2 JOB NO. T18023 ,q I > - ' 110-0' 1 C' C— n ��® Los - 2 1 '7 4T 2, n 1 1120'1 rc I ®� Ic "", 108 °� —E_ m q - W27 x84 ,' / W18x31 48T W18x26 .4? DUSTING 8' BACKFIDW INSTALLED BY OTHERS EXISTING 4• RISER INSTALLED BYOTHERS f-- EXISTING 6' HEADER INSTALLED BY OTHERS 18Kw/: W18 x28 1 HOUR MECH. SHAFT ABOVE NAS. 43} * % l0 11 ,l1 10E u *11 W24 x55 W78x28 W 14x22 HANGER LEGEND SPRINKLER LEGEND N 11I OVERHEAD SPRINKLER PLAN O 4 8 SCALE 114'=1'-0' ABBREVIATIONS SYMBOL LEGEND FITTER / LISTER NOTES 1. ATTACH NEW BRANCHLINES TO CAPPED EXISTING 1.5' SHAPE NIPPLES. 2. SEND 1' PLUGS FOR OUTLETS ON BRANCHUNES. 3. FITTER TO VERIFY CEILINGS PRIOR TO ORDERING DROPS. REVISIONS SYM WVYUFACTURER 5.1N. TYPE MODEL SEE HANGER DETALS THIS SHEET • ®1k 4 RELIABLE RELIABLE RELIABLE RELIABLE TYCO 83615 SSP FIFR 85415 CONC PEND G4A 85415 ,CONC PEND 85714 DRY PEND TY5339 DRYHSW G4A F3QR DS -3 (ECOH) CHR BRZ 8112 CHR CHR CHR CHR BLACK CHR CHR 1/2 1/2' 1/2' 1/L 11.2 K 1/2' 1/2 1/2 155' 165° 155' 288° 155° 32 81 13 8 3 TOTAL THIS SHAT 115 Al* NCO 8® B OP BOT FO 215 FON CRYN NAS VO MOMS F1i94311 R001 BOTTOM OF BEAM 801126 OF 0E0C B OTTOM 2F x1sT 801126 CF PURA BORON OF TMS4 CUr TO 910 FED MEE RACE CF AYNL 00 AUT FACE OF WA AU10LL NO .E MESS NOTED05030DEMME 12 BOD 0 —H -- CENTERLINE OF PIPE TO REFERENCED STRUCTURE N INCHES 2 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCE) POINT N FEET AND INCHES HYDRAULIC CALCULATION NGDE FL.E CELE COUPUNG RIGID COUPLING NO. DATE BY REASON FOR REVISION CONTRACT Wf 11 J R ABBOTT CONSTRUCTION 3512 AIRPORT WAY SOUTH SEATTLE, WASHINGTON 98134-2135 PROJECT MANAGER : JED BICK FORD PHONE: (206) 467.8500 FAX: (206) 447-1885 SUPERINTENDENT : WAYNE JACKSON PHONE: (206) 854.3853 FAX: HANGER DETAIL T ( r CONCRETESTEELPANDECK FLOOR ON j 36' x 33/4' KWIK BOLT -' ^ 318' RO0 COUPLNG (2-5/8' MIN. Ewe)) 3I8'x (2-10) ATR HANGER RING HANGER DETAIL 'K HIL7T 3/8' HDI DROP N ANCHOR 310' x 3-3/4' KWIK BOLT (2-58' MIN. EMBED) 318' RDD COUPLING 318'5 (2-10) ATR (2) HANGER RINGS WITH R) TOLCO FIG. 25 SURGE RESTRAINERS TOLCO FIG. 75 SWIVEL. ATTACHMENT - 3/70 (4-0) RESTRAINT ROD HANGER DETAIL 'KR' 2ND FLOOR (Ir? BRANCHI'E DROP 1'x (ROI SCH-40, MIT WITH 90' ELBOW III 1 1' ELBOW ••::•T: (1-0 ABOVE FINISHED CELLNG) SPRNIOBI FLEX DROP DETAIL 114 (4-3) SCHF40, TXT 1 I� FOAM RUBBER INSULATION FOAM -0 -RM 1' THREADED / TEE AND PWG DRY PENDENT- " A=18' COOLER CELNG DRY PENDENT DETAIL Chi 2RCATE OF DI W ETENCY /UAW KEY Pur 5F5 co 1- z 0 Lll o 0 0 SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 96424 CONTR REG. NO. SMITHFS1380T Bus: ( 253) 926-1880 FAX: ( 253) 828-2350 JOEYS - SOUTHCENTER 633 SOUTHCENTER PKWY TUKWILA, WASHINGTON 98188 DESIGNER 1 DATE M. KELLOGG 1 02/25/08 SHEET 2 OF 2 JOB NO. T18023 �J O EY RE STAU � N ffi FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON AC© ❑ Without Comments As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire 17. c Mention Bureau for conformance with current City standards. Acce«ci--,,:>= is subject to errors and oxissions authorize violations of adopted s':zmdards and r_•i=1ir Ancss. The responsibility for the adequacy of desigr =sts totally with the designer. Additions, deletions o,_ revisions to these drawings after this date wilt void tn..3 i!cceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: ' By: 5 11 SHEET \UMBE SHEET TITLE FA -01 SYSTEM INFO IVATION FA -02 TYPICAL WHI \G A\D MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS A\D SINGLE LINE DIAGA FA -04 FLOO PLAN FRE ALAR v SYSTEM SHEET INDEX QUANTITY E 2 2 3 2 10 E E E E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING HVAC DUCT WORKS TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1G BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING 8 FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2" EXTN CEILING ®E SMOKE DETECTOR (EXISTING) HFP-11 W/ DB -11 BASE SIEMENS EXISTING CEILING HT -D E DUAL INPUT INTERFACE MODULE (EXISTING) HTRI-D SIEMENS EXISTING VERIFY IN FIELD HCP E INTELLIGENT CONTROL POINT (EXISTING) HCP SIEMENS EXISTING VERIFY IN FIELD FIRE ALARM STROBE (EXISTING) ZR -MC -CW SIEMENS EXISTING CEILING gE FIRE ALARM HORN STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING TENANT J -BOX ❑J E (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANDERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED WIRE SCHEDULE A \D CONDUIT FILL CHAT SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION maces LEVELS 250.4075f TUKWILA FIRE DEPARTMENT Pease call 205-575-4407 and give this Fire Permit No. IB -F- 1.0 it ;d exact address for shut- down hutdown or restoration approval. JOEY RESTAURANT 758 NORDSTROM E.: --j amy WFI.E15 I A .Ccf64S InDr SP.Na.R. c=:s KA., IC,: f-v`IA:.4fi JCR ,(ley PAID C �0 F>_$ 2 010 TUKWILA FIRE z 0 w w U) a w w c REV. BY: WIRE DESIGNATI I N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" - .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION maces LEVELS 250.4075f TUKWILA FIRE DEPARTMENT Pease call 205-575-4407 and give this Fire Permit No. IB -F- 1.0 it ;d exact address for shut- down hutdown or restoration approval. JOEY RESTAURANT 758 NORDSTROM E.: --j amy WFI.E15 I A .Ccf64S InDr SP.Na.R. c=:s KA., IC,: f-v`IA:.4fi JCR ,(ley PAID C �0 F>_$ 2 010 TUKWILA FIRE z 0 w w U) a w w c REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 02/13/18 2aa<aa i-oQ28 < L cc o 0 D wwC� Z LIJ v) w Q CC W w� O cc ° SCALE: NOT / 0 in= u.. Z LLI 1=1 TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/13/18 BACKROUND PLAN PROVIDED BY: C:\ \0B NUMBER:27629-1. SYMBOLS / LEGEND GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET--\ SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ — DEDICATED EMERGENCY INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ - 1 2+ 2- 2 NC C NO + - + - + - + - + FROM EXISTING MAIN FACP C CABLE C' CABLE (-) (+) (-) (+) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE NAC S4 • NAC S3 • NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) O c) STROBE SPEAKER (+) (-)C FROM PREVIOUS ADDRESSABLE DEVICE TB1 OCXXIT® NO COM NC EOLR "vvv 470 TO FAN SHUTDOWN o Q TO NEXT o p --"n. ADDRESSABLE DEVICE 0 /1/1/ HTRI-R NO ® COM B NC ® 0 Oj TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (+) \ ) STROBE SPEAKER (+) (-) cm c SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Co yri• ht 2013 by Guardian Security Systems, Inc. All Rights Reserved 141 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: SWITCH + — INPUT LED TSM -1 TO FAN SHUTDOWN o Q TO NEXT o p --"n. ADDRESSABLE DEVICE 0 /1/1/ HTRI-R NO ® COM B NC ® 0 Oj TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (+) \ ) STROBE SPEAKER (+) (-) cm c SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Co yri• ht 2013 by Guardian Security Systems, Inc. All Rights Reserved 141 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 03 M N O "Qm=i("" w 0 0 I— z >- z 0 <— Q o�z cc c o 0 < wwz cn z(,)0 w�0 z CC W<0 O co_ \ -§" 0 >- �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/13/18 BACKROUND PLAN PROVIDED BY: \0B NUMBER:27629-1) SHEET FA -02 A B C D E F G H 1 J K FIRE ALARM BOOSTER Project: JOEY RESTAURANT Panel: EXISTING BPS PAD -3 Date: February 14, 2017 Module/Device POWER BOOSTER Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) .Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 SET,MC-CW @4occi 117 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 2153 Total(A)= 15 Total(B)= 2293 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 2293 Total current ratings converted to amperes (line D x .001) 0.015 2.293 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 528 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.1910069 Add lines G and I Total Standby and Alarm AH 0.5510069 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.66120828 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 CALCULATIONS Notification Appliance Circuit Detail PROJECT::JOEY RESTAURANT Panel: EXISTING BPS PAD -3 BOOSTER POWER SUPE Wire Resistance 2.58 ate: Fe4, 2018 Date:rys...14,018 C#i.URRENT T OjpTAL= 2153.00 bq ru.•«„_l,a y'' Gil � pj . il' y 'l' Y .,. _. 1 1-i 3a ` $.!5,}:: ?:.. .. , [ .. 3 • SET -MC -CW @l5cd 69 207 SET,MC-CW @4occi 117 0 SET -MC -CW @75cd 200 0' 2 SET-Mc-CW.@95cd 264 528 2 ZR -MC -CW @15cd 64 128. ZR -MC -CW @30cd 111 0 DEVICES 7 TOTAL mA= 863 14 221 23.02 863 Total Wire Resistance (R) :(WL 2 )*(Rift) 1.14 Total Device Load, Amps (I) ._._ ..._._ ..._ (Total Cct Load) _.._---. _ _ - 0.86 Voltage Drop (E) (E=1 * R) 0.98 EOL Voltage 24 -E 23.02 i a(Ii Y'R 3•1 -' S i�. - e} '',.t , y5 wdi ` ..# SET -MC -CW @15cd 69, _ _.:. _ .... SET -MC -CW @3Ocd 111 0; 444 SET -MC -CW @75cd 200 0 1 SET -MC -CW ` @95cd 264 -69 264 2 ZR MC -CW @15cd 138 ZR -MC -CW. @30cd 111 0 DEVICES 7 TOTAL mA= 846' 14 236 22.97 846 Total Wire Resistance (R) (W L * 2) * (Rift) 1.22 Total Device Load,. Am ps (1) (Total Cct Load) 0.85 Voltage Drop (E) (E= 1 * R) 1.03 EOL Voltage 24 E) 22.97 ai.^` i�6%fie l 3s1 to i'�`r$ i -0$ SET -MC -CW @15cd 69 0; 4 SET -MC -CW @30cd 111 444 SET -MC -CW @75cd 200 0: SET -MC -CW @a 95cd 264 0 _ SET -MC -W @110cd 233 0+ ZR MC -CW @30cd 111 - 0 DEVICES 4 TOTAL MA= 444: 14 228 23.48 444 Total Wire Resistance (R) .(WL * 2 ) * (Rift) 1,18 Total Device Load Amps l (Total Cct Load)0.44 Voltage Drop (E) '(E=1*R) 0.52 EOL Voltage 24 - E) 23,48 Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0,0023 0.007 FDBZ492-HR 2 0.0635 0.0635 0.064 0.128 HTRI MODULE 5 0.009600 0.0096 0.021 • 0.105 0.0731 Amps 0.233 Amps Notification Appliance nce Circuit Detail - VOICE PROJECT: JOEY RESTAURANT Panel: EXISTING SPEAKER CIRCUIT Date: February 14, 2018 Wire Resistance 2.58 CURRENT TOTAL= 336.30 95 SET -MC @1/4 --WATT 3.54 SET -MC X112 -WATT 7,08 SET @1/4 WATT 14.14 SET @1/2 -WATT 28.29 DEVICES 95 TOTAL mA= Total Wire Resistance (R ) Total Device Load , Amps (1 Voltage Drop (E ) EOL Voltage 336.3 0 0 0 336.3 14 1263 21.81 336.3 (WL*2)*(Rift) (Total Cct Load) (E=I*R) 24-E), 6.52 0.34 2.19 21.81 (HT -R HT -D HCP EXISTING TENANT J -BOX E J EOL S S2 S,V S,V E 2S 2S cc IBPSIE S2-1 S2-2 95Cd 15Cd S2-3 S2-4 15Cd 30Cd S3-1 30Cd S3-2 30Cd S3-3 S3-4 30Cd 30Cd S1-3 95Cd 2S,62V V b EOL S3 S2-5 30Cd S2-6 30Cd S1-1 95Cd S1-2 15Cd S1-4 15Cd S1-5 15Cd SINGLE LINE DIAGRAM S1-6 15Cd S1-7 15Cd S2-7 30Cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 ISI AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 RELEASE/REVISIONS F- o ..‹.:17S «- _i/I < o z 0 D w wz W (1)wQ ›- _ `�(-§ 0 LTJ z 0 ET) 06 z 0 U 0 W co >- O� CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/13/1 8 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 27629-1 J SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved STAFF MEN'S 120 S2-3 15Cd STAFF WOMEN'S 2S 121 S2-2; 15Cdi :REEZE(R 2S —c EOL S2 S2-1 30Cd STAFF RM' 119 `••. Si -1 \95Cd i¢ S,V S,V —o D,S,2V KITCHEN W Y' 4EN'S 08 LOUNGE STORAGE 117 r c0 m 0 1 � z _O I- 0_ V C1) w 0 SHOP DRAWINGS h.�—,, DATE I � �. _ is .; ; II i n - _ 11 p a ,Y "' 7—r -ii : _ ii '.-L«- . C it Zi v I—V LINEN 1111 1 LIQUOR ST RAGE iTi7■� S1-3 95Cd S1-6 15Cd 11 a TSM i — DINING ITING PHASE 1 m PATI /0. ri ❑ ❑ FLOOR PLAN - FIRE ALARM SYSTEM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprieta and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved cc Q c ' � NO co0 O L7 z Q g LL W J I— W C/) Un 1743 IST AVE TEL. (206) 622-6545 (f) Z 0 U) W CC w U) w J W CY REV. BY: c0 m 0 z _O I- 0_ V C1) w 0 SHOP DRAWINGS DATE CO M N 0 I— oQ© o cc z Q�© D < w w z W ")WQ t�C o�c=� y- n W `_ § O ri.P�� n 0 0 LL SCALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/13/18 BACKROUND PLAN PROVIDED BY: \0B NUMBER:27629-1} SHEET FA -04 ee;e DOMING GWB CEILING (PL1N 11'-4 AFF EXISTING ACOUSTIC CUING 1Z -1 -AFF 1Z-0tu APF (0-16) ' D0SO3 StP 30 3 03 00 00 5 03 LO SOS Cxas 1 vramizatmiemismsm s, 4. le is'L79.7'a.T.111.101011111.1611611111T 4i • 6,1I2 - EXISTING GM CEILSIG (PT -IA) fa 11.-11' AFF • (0,18) -aarrm 5 —4, _ -�-- {p� sojii =s ta8 D l {{jj Al (0 '.l ppp Iilll 0 6 II - • Kim 1�X l• HSA D (Dbl — Ill wrift 11. .I , I 03-9) — 0 ® `�'• 0 4 I LA D L-10 L-10 L-10 tea -9. NEW DROPPED GWB cets4a 1V-6'AFF- .- 5 —4, _ -�-- _- sojii =s ta8 _aw =(D3lj=. tea -9. NEW DROPPED GWB cets4a 1V-6'AFF- .- ' ' • atD'aAFF ' . EXISTING 'GM minis (PT -2) • - 1 -IA 0.29) •Ilt (3-19) Ilk It riiii 1-E( ' (0.19) -\. •- . -_ 1G610 _r jD-1D)_ -�-- _- sojii =s ta8 _aw =(D3lj=. ' ' • atD'aAFF ' . EXISTING 'GM minis (PT -2) • - 1 -IA 0.29) •Ilt (3-19) Ilk It riiii 1-E( ' (0.19) -\. •- . -_ 1G610 _r jD-1D)_ -�-- _- sojii ta8 24)_0=--,-,-- =(D3lj=. ' ' • atD'aAFF ' . EXISTING 'GM minis (PT -2) • - 1 -IA 0.29) •Ilt (3-19) Ilk It riiii 1-E( ' (0.19) -\. •- . -_ 1G610 _r B.G. Woof) SLAT CEILING, TYP. 0412-3) 10'TAFF EXISTING GWB CEILING (PL -1A)' 0.0. A6ous1IC cEAING, TYF. (ACT-() 1,4" AFF . a, 109T AFF EXISTING 6118 CEILING (PT -IA) (0.19) 0 Corrugated stainless steel hose with stainless steel bral available in 2', 3',4'5 & 6' legnths . • . • • Multi -Port Bracket • • • Adjustable Hub F xHspj2 I INOUsI RIES•-'J Flexhead'"bomrtiercial Ceilirig Unit •' T-bar'Ceiling Installation ' Model #2024,2036,2048,060,2672 Design per NFPA 13 Ordinary Hazard Group 2 — 130 Square Feet Max All materials to be new, U.L. listed and F.M. approved All heads to beat least 6' apart with no obstructions • 3 - Relocate Reliable Model G5-56 Concealed Quick Response 165 Pendents % x'/2 • 3 — Plug existing • E - Existing no change Change out existing trim from silver to black (except for in the BOH acoustical grid ceiling, and restrooms) o' ;Q 4tY o Without Comments p As Noted in Rei. 't'• Per Thee ci^e2 Letter er - These plans have been reviewed bv Tile Tukwila Fire Prevention Bureau for conformance with current Cit` standards. Acceptance is subjeC'to rors and _ omissions which do not a'.i' hori2.e violations adopt =(1 standards and ordinances. The re.soo sinility for the adequacy of design itotally with the -Additions, d i izotdrawings tS �'. ce vIsior.s to t 1e7L fl S :� rav1 a -r this date Will void [s 1;3 ccceptarlCC and will require e i resubmittal of revised 6:-tiwlncs for s�so' g9�ent aopro''f• ai, Final acceptance is suo)ect to field test and inspection by The Tukwila Fire Pceventior',Sureau. Date: t> 1- 1 By: -•�: i ')I 9 �T.qa.• ,Vy, "1 j3 tom. i i c`lil� i=s I=':ta D; ir?RTh1E,'.3'�$ 1 205-575407 and Fife 1\4.0„ S -a,-1 I t4 e. 8ck- r.=ss for , r approve. 47R pi i$ PROTECTION RPRf1 J. -Abel "60 -0591 -CG: LAW 3' ;rrwn Fire pep iont;.(r`Ic._ CIh`4?WNi'G4gld: otl•,ymmtulre 001044 WWW WWW CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 - MILL CREEK, WASHINGTON ' 98082-0113 PH. (425) 481-7669 Joey Southcenter Westfield Mall - 758. Southcenter Mall Tukwila, WA 98188 ID. v 2O1) �. .-FIRE - vi 36vr�. DATE: 2,) SCALE: sojii 24)_0=--,-,-- =(D3lj=. B.G. Woof) SLAT CEILING, TYP. 0412-3) 10'TAFF EXISTING GWB CEILING (PL -1A)' 0.0. A6ous1IC cEAING, TYF. (ACT-() 1,4" AFF . a, 109T AFF EXISTING 6118 CEILING (PT -IA) (0.19) 0 Corrugated stainless steel hose with stainless steel bral available in 2', 3',4'5 & 6' legnths . • . • • Multi -Port Bracket • • • Adjustable Hub F xHspj2 I INOUsI RIES•-'J Flexhead'"bomrtiercial Ceilirig Unit •' T-bar'Ceiling Installation ' Model #2024,2036,2048,060,2672 Design per NFPA 13 Ordinary Hazard Group 2 — 130 Square Feet Max All materials to be new, U.L. listed and F.M. approved All heads to beat least 6' apart with no obstructions • 3 - Relocate Reliable Model G5-56 Concealed Quick Response 165 Pendents % x'/2 • 3 — Plug existing • E - Existing no change Change out existing trim from silver to black (except for in the BOH acoustical grid ceiling, and restrooms) o' ;Q 4tY o Without Comments p As Noted in Rei. 't'• Per Thee ci^e2 Letter er - These plans have been reviewed bv Tile Tukwila Fire Prevention Bureau for conformance with current Cit` standards. Acceptance is subjeC'to rors and _ omissions which do not a'.i' hori2.e violations adopt =(1 standards and ordinances. The re.soo sinility for the adequacy of design itotally with the -Additions, d i izotdrawings tS �'. ce vIsior.s to t 1e7L fl S :� rav1 a -r this date Will void [s 1;3 ccceptarlCC and will require e i resubmittal of revised 6:-tiwlncs for s�so' g9�ent aopro''f• ai, Final acceptance is suo)ect to field test and inspection by The Tukwila Fire Pceventior',Sureau. Date: t> 1- 1 By: -•�: i ')I 9 �T.qa.• ,Vy, "1 j3 tom. i i c`lil� i=s I=':ta D; ir?RTh1E,'.3'�$ 1 205-575407 and Fife 1\4.0„ S -a,-1 I t4 e. 8ck- r.=ss for , r approve. 47R pi i$ PROTECTION RPRf1 J. -Abel "60 -0591 -CG: LAW 3' ;rrwn Fire pep iont;.(r`Ic._ CIh`4?WNi'G4gld: otl•,ymmtulre 001044 WWW WWW CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 - MILL CREEK, WASHINGTON ' 98082-0113 PH. (425) 481-7669 Joey Southcenter Westfield Mall - 758. Southcenter Mall Tukwila, WA 98188 ID. v 2O1) �. .-FIRE - vi 36vr�. DATE: 2,) SCALE: ULC Listed Filter Detail Kleen-Gard Baffle Type Filters arc UL Classified Grease ExtractingFilters. MEA # 168-78-M Aluminum MEA # 247-96-E Stainless RESISTANCE VS. AIRFLOW - r Kleen-Gard Baffle Type Grease Filters 10 0.6 0.4 02 0275 0.175 0125 0.075 150/ 0.76 070 /1.01 250/127 700 /132 15011.76 AIRFLOW (fpm/m/s) 0025 400/203 COMPOMOTIOlt 3 CALCULATIONS UTILIZED EXHAUST CFM=LENGTH OF HOOD X CFM/UN.FT. (LOAD) SUPPLY CFM=EXHAUST CFM X PERCENTAGE REQUIRED CFM TOTAL DUCT AREA=144 X DUCT LENGTH= FPM(*) TOTAL DUCT AREA DUCT DEPTH * CAPTIVE-AIRE VENTILATOR DUCT SIZES ARE CALCULATED USING AN EXHAUST VELOCITY OF 1500-1800 FPM AND A SUPPLY VELOCITY OF 700 FPM PLEASE CONSULT FACTORY FOR MAXIMUM ALLOWABLE DUCT SIZES BUILDING CODES CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH: s s s s NFPA #96 NSF USTED B.O.CA #93-16 I.CB.O. 34416 SBCCI PST & ESI NO. 93137 E.T.L LISTED 3054804-001 LOS ANGELES RRIB080 ETL IS LISTED TO ULC STANDARDS NFPA® ETL "c" LISTING DESCRIPTION THE CAPTIVEAIRE MODEL ND HAS BEEN U.L. 710 TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 150 CFM PER LINEAR FOOT OVER 450 DEGREE COOKING EQUIPMENT ND -2 HANGING ANGLE DETAIL 1/2 DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE 1/r DIA. HEAVY DUTY NUT ONE ABOVE AND ONE BELOW HANGING ANGLE * ROD AND NUTS TO BE SUPPUED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY FOR PRICES AND QUESTIONS CAPTIVEAIRE CANADA P: 800.382.2194 E: REG20@CAPTIVEAIRE.COM F: 866.845 9754 APPROVAL TO MANUFACTURE: Approved Approved as Noted ❑ with ND Exception Taken ❑ Revise and Resubmit SIGNATURE REQUIRED BY: ENGINEER ARCHITECT DETAIL OF SUPPLY AIR VOLUME AND FIRE DAMPER ASSEMBLY 1' FLANGE FOR DUCT CONNECTION ACCESS FOR VOLUME DAMPER ADJUSTMENT SCREW (SOCKET HEAD SCREW REQUIRES 3/16 ALLEN WRENCH) TO CLOSE DAMPER: TURN SCREW CLOCKWISE. TO OPEN DAMPER, TURN SCREW COUNTERCLOCKWISE. (NOTE: DAMPER ASSEMBLIES LONGER THAN 30' HAVE TWO OBD - ADJUSTMENT MUST BE MADE AT BOTH ENDS) 7' NOM OPPOSED BLADE VOLUME DAMPER 1' FLANGE FOR CONNECTION TO HOOD 4.5' NOM 12' MA. - EXTENDS BELOW TOP OF HOOD U.L. FIRE DAMPER (INSIDE) WITH 212 DEG. FUSIBLE LINK ETL LISTING DESCRIPTION BLOCK THE CAPTIVE AIRE MODEL ND HAS BEEN U.L. 710 TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 200 CFM PER LINEAR FOOT OVER 600 DEGREE COOKING EQUIPMENT 3.00' 54.00' 12.00' 42.00' 10.00' Hood - H-5 (DISHW) 21.00' J L- 10.00' 1 10.00' 21.00' J L- A 24.00' 48.00' 8' 0.00' 24.00' PLAN VIEW - 8' 0.00" LONG 4224VHB-G DISHWASHER HOOD 12.00' PLAN VIEW - 6' 6.00" LONG 4824ND-2-PSP-F 0 1 z zw Q� >- z V U Z U I - w Zw <0 U f~-6 w J Ce 45.00' 6' 6.00' 39.00' 45.00' 28.00' 39.00' U.L. Listed Screw In Compact Fluor 0 Hood - H-4 1 r 10.00' 10.00' E 10.00' 0 ISI A 12.00' 48.00' 1 3.00' Or 11.1 v a -i MODEL 10.. + + + ... + • LENGTH MAX. C❑❑KING TEMP. EXHAUST PLENUM SUPPLY PLENUM HOOD C❑NSTRUCTI❑N EMS SYSTEM PACKAGE r 10.00 r 10.00' Q TOTAL EXH. CFM RISER(S) TOTAL SUP. CFM RISER(S) WIDTH LENG. DIA. 10.00' S.P. WIDTH LENG. 10.00' CFM S.P. 1 5424 ND -2 -PSP -F 10' 0.00' 10.00'- 1750 - � _/' 1750 -0.576' /0 /0 --I 10.00 875 YA 430 SS Where Exposed LEFT FRONT 1 16 r L11.00'1 Hood - H-3R(MAIN) U.L.Listed Screw In Compact Fluor L16.00'� Hood - H -1L (MAIN) U.L. Listed Screw In Compact Fluor 26.00' Hood - H -2M (MAIN) lit. Listed Screw In Compact Fluor. 24' 0 O L LI Q D.... •...•... 10' 0.00' 600 Deg. 2750 10' 26' 3 2750 -0.857' 1800 10' 20' .... 900 0.151' 430 SS Where Exposed MIDDLE -� ice, �- 0.00' 10.00"00' YES 11,0001 .� 1- .��/ // 20' 4 900 -% '/� 10.00' 542410' ND -2 -PSP -F % Incandescent Light 1196 10.00' - - 3.0/3.0/3.0 1196 10.00'7-/� 10.00' 1196 10' 28' 6.00' ISI % 6.00' lel ISI RIGHT 1�1 % 6.00' �% 6.00' o I ��i, //_ % 6.00' lol 4824 ND -2 -PSP -F 6' 6.00' 450 Deg. 10' ,,,j1;��i�,_�I_ 1138 -0.509' •10' 28' 1138 30.00' 24.00' 60.00' 60.00' 10' 0.00' 24.00' 60.00' J 30.00' 30.00' 20.00' 60.00' L. PLAN VIEW - 10' 0.00" LONG 5424ND-2-PSP-F 1 l V .-04.., HOOD NO. 11.1 v a -i MODEL 10.. + + + ... + • LENGTH MAX. C❑❑KING TEMP. EXHAUST PLENUM SUPPLY PLENUM HOOD C❑NSTRUCTI❑N HOOD C❑NFIG. ENDTOO ROW TOTAL EXH. CFM RISER(S) TOTAL SUP. CFM RISER(S) WIDTH LENG. DIA. CFM S.P. WIDTH LENG. DIA. CFM S.P. 1 5424 ND -2 -PSP -F 10' 0.00' 450 Deg. 1750 10' 16' 1750 -0.576' 1750 10' 24' LBS. 875 0.120' 430 SS Where Exposed LEFT FRONT 6 16 r 20 r 3 Screw In Compact Fluor 10' 24' 875 0.120' 2 5424 ND -2 -PSP -F 10' 0.00' 600 Deg. 2750 10' 26' 3 2750 -0.857' 1800 10' 20' Screw In Compact Fluor 900 0.151' 430 SS Where Exposed MIDDLE FRONT 1 Light 1 Fan 1 Other Outside YES 541 LBS. 10' 20' 4 900 0.151' 3 542410' ND -2 -PSP -F 6'10.00'450 Incandescent Light 1196 Right 11' 3.0/3.0/3.0 1196 -0.515' 1196 10' 28' 3 1196 0.148' 430 SS Where Exposed RIGHT FRONT 0 4824 ND -2 -PSP -F 6' 6.00' 450 Deg. 10' 10' 1138 -0.509' •10' 28' 1138 0.145' 430 SS Where Exposed ALONE BACK 5 4224 VHB-G 8' 0.00' 700 Deg. 1200 10' 10' 600 -0.075' 0 304 SS 1007 ALONE N/A 10' 10' 600 -0.075' 60.00' 10' 0.00' 20.00' 60.00' 30.00' 41.00' 28.00' 47.00' PLAN VIEW - 10' 0.00" LONG 5424ND-2-PSP-F n u(J.0 HOOD NO. 11vr VIL1V1131 1111V FILTER(S) LIGHT(S) UTILITY CABINET(S) FIRE SYSTEM PIPING HOOD WEIGHT TYPE QTY. HEIGHT LENGTH QTY. TYPE WIRE GUARD L❑CATI❑N FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL # QUANTITY L❑CATION 1 Stainless Steer (High E 6 16'2 r 3 Screw In Compact Fluor NO YES LBS. 2 Stainless Steel (High E 6 16 r 20 r 3 Screw In Compact Fluor NO YES LBS. 3 Stainless Steel (High E 4 16' 20' 2 Screw In Compact Fluor NO Right EMS21102 1 Light 1 Fan 1 Other Outside YES 541 LBS. 4 Stainless Steel (High E 1 16' 16' 2 Incandescent Light NO Right Ansul R102 3.0/3.0/3.0 YES 525 LBS. 3 16' 20' 5 0 NO 244 LBS. s Without Comnentt As Noted In Red Per The Attached Letter 1 nese plans have been reviewed by The Tukwila Fir Prevention Bureau for conformance with current city standards. Acceptance is ±LIblect to errors and omissions whch do not authorize violations of adopted stanGares and e;:rnances. The ref..iporisibilitv for the adequacy o1 d c,i9n r Sts to ally v/ith me designer. Additions, deie ions or r.i:vISICns to these drawings atter this dato. 1..vil, void thaw acceptance znd will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to ieid test and inspection by The Tukwila Fi4e Prevention Bureau. Date: S -1-3 By: J 41.00' 6' 10.00'Noti./6' 10.00'❑D 47.00' PLAN VIEW - 6' 10.00" LONG 5424ND-2-PSP-F TLIKWILA FIRE DEPARTM Please call: 575-440Z - and give this job No. 0 3 " 14 - 0..3., and exact address for shut' cpwn or cast :ration approval, 12.00' { 3.00' 54.00' LIGHT AND 12.00' FAN SWITCHES 1 JOB J❑EYS ❑PM LOCATION WA .DATE 12/15/07 JOB # .DWYC # J❑EYS JJRANOV BYESJ REV 4 SCALE 3/4" ULC Listed Filter Detail Klcen-Gard Baffle Type Filters are UL Classified Grease Extracting Filters. MEA # 168-78-M Aluminum MEA # 247-96-E Stainless RESISTANCE VS. AIRFLOW - 2" Kleen-Gard Baffle Type Grease Filters 1A as as 0i 0.2 1501016 100/1D1 e50/121 300/132 15011.75 AIRFLOW (fpm/m/s) 0223 0175 0125 0075 0025 CO/ 203 CALCULATIONS UTILIZED " EXHAUST CFM=LENGTH OF HOOD X CFM/LIN.FT. (LOAD) SUPPLY CFM=EXHAUST CFM X PERCENTAGE REQUIRED CFM TOTAL DUCT AREA=144 X DUCT LENGTH= FPM(*) TOTAL DUCT AREA DUCT DEPTH * CAPTIVE-AIRE VENTILATOR DUCT SIZES ARE CALCULATED USING AN EXHAUST VELOCITY OF 1500-1800 FPM AND A SUPPLY VELOCITY OF 700 FPM PLEASE CONSULT FACTORY FOR MAXIMUM ALLOWABLE DUCT SIZES BUILDING CODES CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH: • NFPA #96 * NSF LISTED • B.O.C.A. #93-16 • I.CB.O. 34416 s SBCCI PST & ESI NO. 93137 • E.T.L. LISTED 3054804-001 * LOS ANGELES RR#6080 • ETL IS LISTED TO ULC STANDARDS ETL "c" LISTING DESCRIPTION THE CAPTIVEAIRE MODEL ND HAS BEEN U.L. 710 'TES'T'ED, LIS'T'ED, AND APPROVED TO EXHAUST A MINIMUM OF 150 CFM PER LINEAR FOOT OVER 450 DEGREE COOKING EQUIPMENT ND -2 HANGING ANGLE DETAIL 1/2. DUI. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE 1/2' DIA. HEAVY DUTY NUT ONE ABOVE AND ONE BELOW HANGING ANGLE * ROD AND NUTS TO BE SUPPLIED BY INSTAWNG CONTRACTOR HANGING ANGLE IS PRE—PUNCHED AT FACTORY FOR PRICES AND QUESTIONS CAPTIVEAIRE CANADA P: 800.382.2194 E: REG20@CAPTIVEAIRE.COM F: 866.845 9754 APPROVAL TO MANUFACTURE: Approved as Noted El Approved with NO Exception Taken ❑ Revise and Resubmit ❑ SIGNATURE REQUIRED BY: ENGINEER ARCHITECT HANGING ANGLE 3' STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS EXHAUST RISER -4' 16" U.L. CLASSIFIED BAFFLE -TYPE GREASE FILTERS 100W VAPORPROOF INCANDESCENT LIGHT Q 2.75' E— ' 12'� 24' NOM SUPPLY RISER WITH VOLUME DAMPER GREASE DRAIN WITH REMOVABLE CUP 54' 33' MIN 48' MAX EQUIPMENT BY OTHERS 4 78' TYP. SECTION VIEW — MODEL 5424—ND-2 with, PSP Accessory NOTE: HOOD (S) # 1,2,3 & 4 4' EXHAUST RISER -I `FULL LENGTH ANGLE (TYPICAL) j FULL PERIMETER J GUTTER �L1 DRAIN ALUMINUM MESH FILTER 24' 42' EQUIPMENT BY OTHERS 4 SECTION VIEW — MODEL 4224—VH1 WITH FULL PERIMETER GUTTER NOTE: HOOD # 4 23.5% OPEN STAINLESS STEEL PERFORATED PANEL VERIFY CEILING HEIGHT / /i Height required to verify that the hood will fit and to size the enclosure panels INSTALLER TO FASTEN WRAPPER TO FACTORY C—CHANNEL WALL WRAPPER PANELS FLANGED FOR RIGIDITY I 1.11 WRAPPER FRONT CANOPY HOOD - WRAPPER END PRESS FIT UNTIL PANEL FACES ARE FLUSH WITH HOOD AND POP RIVET OR SCREW PANELS TO C—CHANNEL COMPLETED WRAPPER ASSEMBLY WRAPPER SCREW OR POP—RIVET POSITION BOTTOM 3/8' FLANGE OF WRAPPER UNDER C—CHANNEL FACTORY MOUNTED C—CHANNEL /TOP OF HOOD SIDE OF HOOD FIG.1 WRAPPER DETAIL SLIDE SIDE PANEL BETWEEN WALL AND 'L' BRACKET. POP RIVET OR SCREW SIDE PANEL TO WALL 'L' BRACKET. NOTCH REQUIRED WHERE SEAM_MEETS WRAPPER FIG.3 TOP HOOD SEAM DETAIL FASTEN 'L' BRACKET TO WALL WALL 'L' BRACKET INSIDE OF SIDE PANEL FIG.2 WALL ANGLE JOB WRAPPER INSTALLATION LOCATION BATE 11/27/96 JOB # DWG# HOODINST DRAWN BY JFR REV SCALE NOT TO SCALE BACKSPLASH BACKSPLASH KINK OVERLAPPED BY ADJACENT SECTION - AVAILABLE IN VARYING HEIGHTS AND LENGTHS - EASILY CLEANABLE - ONE PIECE BACKSPLASH (OVERLAP KINK OMITTED) AVAILABLE AT HEIGHTS OF 4 FT. OR LESS AND AT LENGTHS OF 16 FT. OR LESS HOOD OPTIONS HOOD NO. OPTION H -1L BACKSPLASH 80.00' High X 120.00' Long 430 SS FIELD WRAPPER 17.00' High Front, Left, H -2M BACKSPLASH 80.00' High X 120.00' Long 430 SS FIELD WRAPPER 17.00' High Front, H -3R BACKSPLASH 80.00' High X 94.00' Long 430 SS FIELD WRAPPER 17.00' High Left, H-4 BACKSPLASH 80.00' High X 90.00' Long 430 SS FIELD WRAPPER 17.00' High Front, Left, Right, H-5 FIELD WRAPPER 17.00' High Front, Left, Right, 2 JOB JDEYS DPM LOCATION WA .DATE 12/15/07 JOB # DWG # J❑EYS I2RATYN BYES) REV: 4 SCALE 3/4" HINGE KIT DETAIL FAN BASE CURB PLATE (LEFT) FAN PLATE (LEFT) GREASE BOX (OPTIONAL) GREASE PIPE (OPTIONAL) FAN IN OPEN POSITION FAN BASE ATTENTI❑NL INSTALLER SHOULD SUPPLY ENOUGH ELECTRICAL CORD TO LET FAN MAKE COMPLETE SWING. BI SERIES RESTAURANT DUTY UTILITY SET F D AU K SHAFT DIA. FEATURES: - FULL AMCA CLASS 1 OPERATION - VENTED MOTOR COVER FOR WEATHER PROTECTION - UL762 LISTED FOR RESTAURANT DUTY - UPBLAST DISCHARGE DIRECTS AIR AWAY FROM FLOOR - CONTINUOUSLY WELDED HOUSING - CLEANOUT DOOR WITH LATCHES PROVIDE EASY ACCESS WITH❑UT TOOLS - 2' GREASE DRAIN WILL NOT CLOG OPTIONS: EMERGENCY DISCONNECT SWITCH VIBRATION IS❑LAT❑RS - OPTIONAL SUPPORT RAILS FF GENERAL & RESTAURANT DUTY UTILITY SET DIMENSIONAL DATA FAN MODEL AU E D W E C F G H CC K WEIGHT LB ❑ 27 P 28 S 2 T 21 V SHAFT DIA. APPR❑X SHIPPING [LBS) HH V FF BUS 35 13/16 19 3/8 14 1/2 37 7/8 22 31 16 9/16 19 3/8 21 1/8 11 1/2 14 11/16 17 3/4 1 3/16 220 10 4 48 BI22 44 3/8 23 5/8 17 5/8 48 5/16 28 40 7/8 25 1/4 23 5/8 27 11/16 14 5/8 22 3/4 21 5/8 1 3/16 430 10 4 60 UPBLAST EXHAUST FANS (UL762) HT B } R G=R+3' RO C 4REASE DRAIN 2G FEATURES: - ROOF MOUNTED FANS - RESTAURANT MODEL - UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300°F (149°C) - GREASE CLASSIFICATION TESTING - VARIABLE SPEED CONTROL (DU MODEL) NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITH❑UT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BEC❑MING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) NCAHPFA BELT DRIVE CENTRIFUGAL UP -BLAST EXHAUST FANS DIMENSIONAL DATA FAN MODEL HT E DU5OHFA W B C Natural F R CC RO WEIGHT LB DU5OHFA 27 1/4 28 7/8 2 21 21 1/2 13 1/4 17 1/2 55 VENTED CURB 20 GAUGE STEEL C❑NSTRUCTI❑N 3' FLANGE RO RO CURB DIMENSI❑NAL DATA ROOF OPENING DIMENSIONS FAN MODEL D E DU5OHFA 19 1/2 20 GREASE BOX INSTALLATION CURB GREASE BOX GREASE BOX COVER FOR PRICES AND QUESTIONS CAPTIVEAIRE CANADA P: 800.382.2194 E: REG20@CAPTIVEAIRE.COM F: 866.845 9754 MODULAR OUTDOOR SIDE DISCHARGE INDIRECT FIRED HEATER WITH COOLING COIL, V—BANK FILTER AND INTAKE HOOD GAS FIRED MAKE — UP AIR UNIT(S) FAN UNIT NO. BTU's TEMP. RISE GAS TYPE 3 587459 80 deg F Natural —® ® DIM "X' —®– DIM 'V' –0— DIM "W" DIM "Y" - 1 ---�I DIM "M" DIM "D" DIM 20 IN HIGH EQUIPMENT CURB 1' MPT C❑NNECTI❑ FOR SS PITCHED DRAIN PAN DIM 'B" DIM 'BB DIM 'A' 0 L CURB OUTER WALL INDIRECT MODULE FLEX CONDUIT FOR FIELD WIRING V -BANK FILTER MODULE AIRFL❑W DIM "F" IJ C❑IL CONNECTIONS DIM 'CC' DIM "C' "E' POWER VENT HOOD* miiimmommlb IFTING LUGS SERVICE DISCONNECT SWITCH 0 0 0 C=== ) * o ALL DIMENSI❑NS ARE NOMINAL AND GIVEN IN INCHES. DIM "G" O O O O 0 O BLOWER/ MOTOR ACCESS DOOR FILTER ACCESS DOOR DIM 'H" DIM "J' DIM "K' DIM 'Z' DIM 'L' ROOF OPENING 2' SMALLER THAN CURB DIMENSION INTAKE HOOD MODEL u BTU RANGE (MBH) UNIT DIMENSIONS DISCHARGE OPENING TONNAGE RANGE WEIGHT A B BB C CC D E F G H J K L M V W X Y I.800-918 2546 LBS 215-3/8 52-11/16 54-3/8 54-3/8 56-3/8 49-1/165-1/4 @13000 CFM = 566 FPM 51-5/8 11-5/16 87-1/16 84 129 174 35 30 29-5/8 11-1/2 7-3/8 MODEL u BTU RANGE (MBH) GAS PRESSURE**GAS CONNECTI❑N TONNAGE RANGE MODEL CFM RANGE CFM BURNER INPUT BTU LOW BTU HIGH MIN MAX 'Z' (NPT) MIN MAX FILTER SIZE R. QTY MIN MAX MAX. FILTER VELOCITY I.800-918 800 MBH 128 640 7' WC 14" WC 1 10 Ton 25 Ton 20'x25'x2° (8) 5000 13000 @13000 CFM = 566 FPM APPROVAL TO MANUFACTURE: Approved as Noted Approved with NO Exception Revise and Resubmit SIGNATURE REQUIRED BY: ENGINEER ARCHITECT Taken ❑ 1-1YtY 11Yl 1/1 Ylrinllvl. FAN UNIT MODEL # EXHAUST FAN SUPPLY FAN FAN UNIT NO. MODEL TAG CFM S.P. RPM H.P. 0 VOLT FLA BLOWER H❑USING TAG CFM S.P. RPM H.P. 0 VOLT FLA 1 BI22CARM EF -1 BI22CARM CLOSED 4500 - 3.147' 1349 5.000 3 460 6.4 CLOSED 2 BI18CARM EF -2 BI18CARM 2334 - 2.724' 1488 2.000 3 460 3.0 3 A3 -L800-918 MUA-1 918 A3-INB.800 5884 1.250' 773 7.500 3 460 9.4 4 DU5OHFA DISH DU5OHFA 1200 - 0.750' 1336 0.500 1 115 8.1 DRAWING NUMBER EMS21102 MODEL EMS21102 1 oWH 10 11 12 13 14 15 16 17 18 19 20 21 22 0BK Frio LT, -01 .BK 1 2 PR BK PB -01 36-1--4 OR TI -01 OR K DELAYED t]IcL BK TI -01 A A2 K 7E-03 0R MS -01 RE -01 C NC BK A B NO ® RE -02 RE -01 BK Acc›B WH rtNR��4 friffe.Rfl WH RE -03 BK AccoB WH LT -02 WH WH 1 S YW 12 W-01 RE -01 42D40/0L 0D YW -2-131_=0:01,_2i . GY 13A 13B RE -01 J2D 7q 1 Y SC -01 (Sup -1) 13C LI L2 GY GYWPM TI -01 L_ .GY IN ANT BL C NC L C S NC BK BK p BK BK0 L3 BK ® BK o RD ® RDp T2 RD ti*rca RD.. TO MOTOR T3 RD ® RD o GY 3 PHASE INPUT TI RD YW 2 13A 13B 13C SC -02 (Exh-1) Duct Stats are Factory Wired W Control Is Installed In the Hood Cabinet. GY Ll BK Erma BK.: L2 BK BK L3 BK Ian BK T1 RDgx<> Rn,: T2 RD ® RDo T3RD El: nnaRD RDS YW YW 1 1 All external control wires to motor speed control should be 16-20 AVG shielded 23 nulticonductor cables and must not be run In the sane conduit or raceway with any high power wiring. Ground Shielded Cable at the drive chasis ONLY. 24 25 PG. 25 OF THE DRIVE MANUAL DESCRIBES STARTUP PRE AND EXPLAINS PARAMETER SETTINGS PG. 29 OF THE DRIVE MANUAL DESCRIBES THE PARAMETER SETTD4GS IF THE DRIVE 2 13A 13B 13C L1 L2 SC -03 (Exh-2) 3 PHASE INPUT TO MOTOR GY BK LLa BK BK L3 T1 RCM BK BK o BK T2 T3 RD prai RD RD® RD RD ltArMI RD 3 PHASE INPUT TO MOTOR 181n. x 201n. x 8.61n. Box jnstalled Options Hood Light Switch Exhaust On In Flre Label, LT -01 LT -02 LT -03 MS -01 PB -01 RE -01 RE -02 RE -03 SC -01 SC -02 SC -03 Identlflca ion Location 'POWER ON' Light C1] 'FANS ON' Light (47 '100% OVERRIDE Light C2] Fire System Micro -Switch (5] Push Button Override (3] DPDT Relay (53(63(8) Auxiliary DPDT Relay [5] Timer/Push Button Relay I4] Su -1 Speed Control (6-10) Exh-1 Speed Control Exh-2 peed Control I11-157 (16-20] SW -01 (37(63 SW -02(21 TI -01 100% (3X67 TS -01 Duct Stat (Open on RIseX63 TS -02 Duct Stat (Open on RiseX6] Fan On/Off Switch Hood Light Switch O Override TI a mer CIENERAL DRIVE PARAMETER SETTINGS 03 - AUTO RESTART VITH DC BRAKING (04) 05 - PRESET H1 (02) 10 - PRESET SPEED f1 (04) U - PRESET SPEED *2 (04) 12 - PRESET SPEED *3 (04) 19-100 SEC. 20 - 300 SEG 23 - 60 Hz 24 - 60 Hz S?FiC(FICIDRIVE PAIr�TUETTINGS Paranettwer*-31 = 60 Hz Parameter=31 = 60 Hz Paraneter*32 = 54 Hz Paranetert33 = 48 Hz Paramater*33 = 54 Hz SC -03 (Exh- Parameterit36 = 48 Hz Paronetere31 = 60 Hz Paroneter#33 = 48 Hz SPEED * TB -13A TB -13B TB -13C 1 OPEN OPEN 01,D4 1 [LASED OPEN OPEN 2 OPEN CLOSED OPEN 3 OPEN OPEN CLOSED 4 CLOSED CLOSED OPEN 5 CLOSED OPEN CLOSED 6 OPEN CLOSED CLOSED 7 CLOSED CLOSED CLOSED SPARE RELAY CONTACTS Spare relay contacts can be used to control Items requiring shut down when the fire systen sdischarge; such as shunt tris. 1 NC 3 NO 7 CUM 9 A COIL RE -02-1 MS -02 NC _ . NC • C -RD NO -BK NC -BR Terntal for field wiring to bidding fire contacts fdry or Mgral only. NOTES DENOTES FIELD WIRING DENOTES INTERNAL WIRING Drawing shown De-enerptzed TB -12 must be Junpered to TB -2 for FIRVARD PG. 42 of the drive manual desclbes how to set up the preset speeds. Drive defaults to preset speed *1 when no contacts are made. WIRE COLOR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY OR - ORANGE OR/BL - ORANGE/BLUE RD - RED (STRIPE) WH - WHITE BL/RD - BLUE/RED PR - PURPLE (STRIPE) PK - PINK RD/GN - RED/GREEN (STRIPE) JOB J❑EYS DPM LOCATION WA .1).44 YE 12/15/07 TOB # .12 ITC # JDEYS DRAWN BYESJ REV 4 SCALE 3/4" PLENUM PR❑TECTI❑N NOZZLE DUCT PROTECTION NOZZLE TYPICAL ANSUL R-102 SYSTEM LAYOUT REMOTE MANUAL PULL STATI❑N REMOVABLE STAINLESS STEEL SERVICE DOOR AGENT TANK DEM RELEASE/ BRACKET ASSEMBLY LEGEND FIRE CABINET ANSUL SYSTEM 1A 1.5 GALLON TANK 1B 3 GALLON TANK 2 OEM AUT❑MAN RELEASE 3 OEM REGULATED RELEASE 4 OEM REGULATED ACTUATOR 5 ANSULEX LIQUID AGENT (3 GAL.) 6 ANSULEX LIQUID AGENT (1.5 GAL.) 7 CARTRIDGE (101-20) 8 CARTRIDGE (101-10) 9 CARTRIDGE (101-30) 9A CARTRIDGE (LT -A-101-30) 9B DOUBLE TANK CARTRIDGE 10 TEST LINK 11 DOUBLE MICR❑SWITCH 12 HOSE ASSEMBLY 1100 DUCT NOZZLE (430913) 2W DUCT NOZZLE (419337) 1W NOZZLE ASSEMBLY (419336) 1F NOZZLE ASSEMBLY (419333) 1N NOZZLE ASSEMBLY (419335) 1/2N NOZZLE ASSEMBLY (419334) 3N NOZZLE ASSEMBLY (419338) 245 NOZZLE ASSEMBLY (419340) 230 NOZZLE ASSEMBLY (419339) 2120 NOZZLE ASSEMBLY (419343) 290 NOZZLE ASSEMBLY (419342) 260 NOZZLE ASSEMBLY (419341) 28 DETECTOR BRACKET 29 LOW TEMP FUSIBLE LINK 30 HIGH TEMP FUSIBLE LINK MGV MECHANICAL GAS VALVE EGV ELECTRICAL GAS VALVE 34 REM❑TEiMANUAL PULL STATION S SWIVEL ADAPTOR ANSUL PULL STATION DETAIL PULL SCREW HOLES AT 2 D'CLDCK AND 8 O'CLOCK 1/2' CONDUIT STRAIGHT UP TO ABOVE CEILING LINE, NO OFFSETS DR BEND 4' STANDARD ELECTRICAL OCTAGON BOX 5' ABOVE FINISHED FLOOR DR IN ACCORDANCE VITH LOCAL CODE. A.F.F. NOTE HEIGHT OF PULL STATION SHOULD BE DETERMINED IN ACCORDANCE VITH AUTHORITY HAVING JURISDICTION. FACTORY PIPING - - - - FIELD PIPING ANSUL R-102 FIRE SYSTEM SPECIFICATIONS W In J W ▪ LJ Z J 0 Z¢ LJ = 1 � W 1-10 W Y X CC 1- O LJ MI IW J Z J Z ¢ J CZI- V)I- >- to A LZi A BZW (n LI Hi ¢rx O re• Ni NO¢ ZJ L -L A V) W W I- L- 1 1- Z LL. ¢D3 I -I -A �w 3� W LAJ Q>I- I-H3 1-- Z W X In UJ ce Z 4-4 �V)z .CE z Z ¢U Z LLI F- o ZYCL¢ �0Z� w W -I¢ C] fl ¢ Z 0_LL-wi ¢LIT A I_ W Z J W J W V) A ¢ 2ZL-+O V)O 0 1-IWJ Z¢LI �.Q, Q X W C:1LL- CZ CZA(4 W < O H I- OV)CCO Z W 1- I-W¢Z X I- W `--L W < OLJ LJ H x¢03 W l71 M LJ D A J U ¢¢W� W>ce 4-4 1 3JW 1- W Lj F4 - N A ww¢ ¢WCe O= W La WV)0_1- i Ce 0 - J I- Q.. - J l7 0 z Li Xc¢Li Li CL ¢IOJ w id WF- 1- Z_ (W/)WOJ J 0 z J Ld AP�iy (n WoLL_X U W 1- ¢w v) - LJA¢ H LddLD a_Ji2fO R ¢ ¢ 2rZLLZ�Zi (nJ BUILDING CODES CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH: * NFPA #98 * NSF LISTED • B.O.C.A. #93-16 ✓ 1.C8.0. 34416 • SBCCI PST & ESI NO. 93137 • E.T.L LISTED 3054804-001 • LOS ANGELES RR#8080 ✓ ETL IS LISTED TO ULC STANDARDS CjD NFPA® UL(C) LISTING DESCRIPTION THE CAPTIVEAIRE ANSUL SYSTEM HAS BEEN U.L. 300 TESTED, LISTED, AND APPROVED TO BE PRE -PIPED IN THE FACTORY. FOR PRICES AND QUESTIONS CAPTIVEAIRE CANADA P: 800.382.2194 E: REG20@CAPTIVEAIRE.COM F: 866.845 9754 APPROVAL TO MANUFACTURE: Approved as Noted ❑ Approved with NO Exception Taken Revise and Resubmit ❑ SIGNATURE REQUIRED BY: ENGINEER ARCHITECT r L NOTES - FIELD PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE. - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE, - IF APPLICABLE, PRE -PIPED CHARBR❑ILER DROPS ARE SHIPPED LOOSE. FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE - APPLIANCE DIMENSI❑NS LISTED REPRESENT THE C❑❑KING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS HOOD, NOTE. CAPTIVE' AIRF SYSTEMS ASSUMES RESPONSIBILITY FOR THE PRE PIPING OF THE FIRE SYSTEM BASED UPON THE COOKING EQUIPMENT INFORMATION WE RECEIVE: IT IS THE CUSTOMER'S RESPONSIBILITY TO VERIFY THE COOKING EQUIPMENT LOCATION, SPACING, AND COOKING SURFACE DIMENSIONS. THE CUSTOMER IS RESPONSIBLE FOR ADDITIONAL CHARGES AS A RESULT OF COOKING EQUIPMENT LAYOUT CHANCES AFTER THE RELEASE OF AN ORDER, UNION LABOR CHARGES, OR ADDITIONAL TRIPS MADE BY THE FIRE SYSTEM DISTRIBUTOR CAUSED BY JOB SITE DELAYS. 8z -1 4 T P NT L_ 15' -----T------1 1 1 1 1 L ___ ___ 0 1 0 1 1 1 ___ ___ J- ___ ___ 1 1 1 1 1 ___ ___ JL r ___ 1111111 11' ___ ___ 0 r --- '1 r 0_JL___ Q ___ ___ ___ Q ___ _ --JL----JL 0Gs- 6ula.oJ Aq.lwlxo,.Ad ON Aq_!1 xo.ad '-161H r I 0 1 11. a r00'2Ex 1 ,00'2E Jawnaq_S a r00'2Cx 1 ,00'26 uan❑ I---- ► 1 1 1 ----JL- '10.17' 8z -1 4 T P NT L_ L EXTRA QS,- EXTRA QS 15' -----T------1 1 1 1 1 L ___ ___ 0 1 0 1 1 1 ___ ___ J- ___ ___ 1 1 1 1 1 ___ ___ JL r ___ Q ___ ___ ___ Q ___ I 11' ___ ___ -I Q ___ JL I-13.00' r --- '1 r 0_JL___ Q ___ ___ ___ Q ___ _ --JL----JL 0Gs- '1 10 15' Ir ----- I 11 11 11 0 1 1 1 1 1 r I 0 1 11. 7 0 JL 1 1 r -1 H 11 11 d 1 11 11 JL I---- ► 1 1 1 ----JL- '10.17' 15r 1 1 1 1 r- -1 11,,,r 1 1 1 J • 1 -14.00' ___!--16.00" 15.00' ___1 12,001J-12,00' 13.00' 12.00"--L-10.00" HOOD # 1 14.00' 24.00' 30.00' 15.00' HOOD # 2 12' 12' - HOOD # 3 L EXTRA QS,- EXTRA QS 6 INCHES BELOW HOOD System EXTRA QU CK SEALS TO BE PLUGGED IN FACTORY Size: ANSUL-3.0/3.0/3.0 Total FP required: 29 Long x 54" Wide x 24" High x 16" Long x 54" Wide x 24" High x 26" Long x 54" Wide x 24" High x 11" Long x 48" Wide x 24" High x 10" Fryer -M w/Drip Board 16,00' L x16,00' D High Proximity Fryer -M w/Drip Board 16,00' L x16,00' D High Proximity J fI fo Range -Shelf .. 12,00' L x24.00' D High Proximity - -_ 1 r Oven 38.00' L x24.00' D High Proximity hooa IT Riser # Hood # Riser # 1 1 2 1 r- 1 f !/ Hood # 3 6' 10.00" Riser # 1 Size: 10" r Hood # 4 LJ /----\® # 1 Size: 10" a 1-------1e--L_ ® 12.00'j-12.00' 28 Q11 @ : ------J-(5.I 15.00' -- 28 EXTENDS J p ----1 ei 1N _I r 13.00'. 1 12.00'----10.00' L1® "'' L_ @ -_I__ 30.00' 28 .I 1 -"' 28 --1----- @ ---14.00' 16.00' • 15.00' 13.00' -14.00" 24.00' v NOZZLE 6 INCHES BELOW HOOD System EXTRA QU CK SEALS TO BE PLUGGED IN FACTORY Size: ANSUL-3.0/3.0/3.0 Total FP required: 29 Long x 54" Wide x 24" High x 16" Long x 54" Wide x 24" High x 26" Long x 54" Wide x 24" High x 11" Long x 48" Wide x 24" High x 10" JOB J❑EYS DPM `� 2 Sc C V V L LOCATION WA DATE 12/15/07 JOB # .D TVG # JOEYS .DRAIN. BYESJ REV. 4 SCALE 3/4" Alr) 20 20086) Tukwila Fire -F-00Jotivue1 Fryer -M w/Drip Board 16,00' L x16,00' D High Proximity Fryer -M w/Drip Board 16,00' L x16,00' D High Proximity nge-Shelf (20"Min from gra- 36.00' L x24.00' D High Proximity fo Range -Shelf .. 12,00' L x24.00' D High Proximity (o (o WV) S =off (Oo') S -oro X ON - 3 0 ;71: O-5 O C13 (0 A ci- et) Fryer-M w/Drip Board 16.00' L x16.00' D High Proximity Gas Radiant Charbroiler - S 60.00' L x24.00' D High Proximity NGl 4-5 (0 o Q aQ (0 � r O x O N x - 3_p� Kettle 16.00' L x16.00' D No Proximity Rating Oven 38.00' L x24.00' D High Proximity hooa IT Riser # Hood # Riser # 1 1 2 1 I.U. ULUU Size: 10" 10' 0,00 " Size: 10" Hood # 3 6' 10.00" Riser # 1 Size: 10" Hood # 4 6' 6.00" Riser # 1 Size: 10" JOB J❑EYS DPM `� 2 Sc C V V L LOCATION WA DATE 12/15/07 JOB # .D TVG # JOEYS .DRAIN. BYESJ REV. 4 SCALE 3/4" Alr) 20 20086) Tukwila Fire -F-00Jotivue1 SHEET INDEX FIRE ALARM SYSTEM TUKWILA, WASHINGTON GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL_ DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYTEM FA -03B FIRE ALARM SYTEM ROOF FA -04 SITE PLAN, SYSTEM CALCULATIONS (GENERAL), RISER DIAGRAM. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCT❑RS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO 4416 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR 4414 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR 1414 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED 1118 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWD #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END Without Comments As. Nc Iri Red Per Attached Lotter ese pleas hew', `... ;r r.;.• i. P-evention E r . -.. .c slandardc. O nissians s .anaaro adequacy Pddition5. this date. ,_, I - r submittal of r: ..:; by Tilc; f u1.,. ,it. , ;�Ir cur;cntcit\' and !7.1z2JiY atter G�rea approval. Final accer*inc .suclecT to t:eid tes ana u The Tukwila Prevention Bureau. Date: By: fUKWILA FIRE DEPARTMEN Please call: 575-4402 and give thls job :nd exact address for shut . aovrn or restoration approVa! ' NOTICE A completed, signed, T ukwllei Fire Department Pre-test Certificate must be presented to the Inspector.prior_.to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing, 1,,14/1 //Od a7r cLev<<-e Or+ cie,A;c FA,) -71. qrw b►tsiker. --Sy14c1.,1a cov-rty w'rh' AnyA 7). ?.007 -e oI; FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE,; FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT; AIR STREAM OF AIR SUPPLY OUTLETS. PER NEPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE E SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED: BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHE'!ER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 9. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14: ALL 12OVAC CIRCUITS ARE FROM DEDICATED :CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS 'HALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. - DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS: BETWEEN CONDUCTORS, AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED, ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM " THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. t: 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NEPA 72 2002 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2002 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING- AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE I5 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22` M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 4 1 1 12 3 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY. SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT HTRI-D SIEMENS INTERFACE MODULE 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE - HCP SIEMENS 4S DEEP VERIFY IN FIELD 1 HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD 11.�,,� LINEAR BEAM 31<1 SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1 G RING CEILING DUCT SMOKE ®D DETECTOR AD2-P W/ SIEMENS TSM MODULE. DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING gL C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS. 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM n STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. 9c FIRE .ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. Q FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM FIRE ALARM I B STROBE WP (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2". PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JBOX FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.❑. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAID ` , i - 2008 Tukwila Fire o. ri • ht 2006 b Guardian Securit S stems, Inc. All Ri• his Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS- ,z DESCRIPTION -o it z 'w ;0= ce rcs 0 In w 0 0 co 0 z C C w Qp CJS w z W oC w co O < W se CC OD aCk `SCALE::1 DRAWN BY: '. (.ANDERSON, DESIGNED:: BY: R.VEZZANI DATE: 4/03/0 BACKROUND,PLAN PROVIDED BY: <\OB NUMBER: ;/- SHEET 1 1 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE VATH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' ME, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS DUCT DETECTOR LOCATION o TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT 0 LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL SE END OF LINE DEVICEC3.6K 1/4W) SUPERVISED SWITCH 0 GROUND -0 re) LC) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O 0 O O HTRI-R OSTATUS LED 00 h 0 0 0 N.O. COM N.C. Am TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL SEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE L - + NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING --Th TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE {(-) FROM XLS CONTROL PANEL OR �`¢) PREVI❑US ADDRESSABLE DEVICE (-1 END OF LINE ? 1 DEVICE �T (3.6K 1/4W) SUPERVISED i RELAY CONTACTS SWITCH C4.0A @ 125VAC) GROUND C4.DA @ 30VDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED;. AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE ; 0 0 r) LC) O 0 HTRI-D STATUS LED 0 0 /NOT USED / O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LEL SC4E(FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC lel 0 0 0 110 0 El 0 PAD=3 0 O 0 INPUT .: -INPUT - TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1- 1 2+2-.2.NC C NO + - AMIMI MIAIAKIAK 24K FRONT VIEW NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE _ tea,,, DEVICE LOOP NOT USED REMOTE DEVICE LOOP!. 0- 0 FROM; XIS COMM. PANEL OR (-0> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS iW EOL T M-1 O • TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL i EARTH GROUND 0 -34-E)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE FROM REMOTE POWER SUPPLY C'S' CABLE) END OF LINE DEVICE FROM.. FACP 3.6K 114W) = CVOICE CIRCUIT) ('V' CABLE) UPERVISED 1 SWITCH SCALE NONE (-a) (-) STROBE SPEAKERr () STROBE ( ) STROBE SPEAKER (+) (-) a SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STRO3E ONLY 11111 Q O NAC -4 2 NAC -3 NAC -2 ?NAC -1 4S DEEP BOX W/ 1 -1/2 - EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERMIN TEMPERA +327 (0' C TO 10O' F C HUMIDITY; O- X RELATIVE HUNT TY.. NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE f DATA IN (-) > - t DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCOTY APPLICATIONS OF 300-4000 FTAIN MEN USED IN CONJUNCTION *111 DUCT HOUSINGS AD -11P OR AD-11XPR D8--11 /� STANDARD SMOKE DETECTOR BASE TO NEXT DEVICE F REAR VIEW > ( ) DATA OUT > (1-) DATA OUT HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SUE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID —\ HARD LID CEILING SPEAKER SUPPORT TILE" ------ BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION `\. -----CEILING MOUNTED ----N SPEAKER/STROBE W cc D REV; BY: Z:` a:Q ---- ---- ... .----.. w. DESCRIPTION---- ------ ------ . PRELIMINARY SHOP_ DRAWINGS..... OD 3/18/08-=- z C«<C CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTI❑N BOX MOUNTED ON . \ CEILING FLEX \ / / / / f / / / JUNCTION BOX --=-\ MOUNTED AGAINST CEILING SUPPORT 0 0 ; I TO NEXT DEVICE 0 0 -CADDY BAR SMOKE DETECTOR ----- SUSPENDED ILLUMINATED CEILING ALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SLATE=NONE SMOKE DETECTOR MOUNTING SCALE:NONE SCALE:; DRAWN BY: (.ANDERSON DESIGNED . BY: R.VEZZANI DATE: 4/03/08 BACKROUND:PLAN PROVIDED BY: JOB NUMBER: Copyright -'2006 by Guardian Security Systems, Inc. All Rights Reserved 4 1 - — - 2s,2V �i a > N H N $P 0 HCP i1\\ ill A 2S,2V N EOL S2 19.35 75 • >• -0 S,2 V,D 1-1 N COL Si 18.50V II 30 2S,2V id 75 S,2 V 110 2V,S 2S,2V 0 11 110 Ti s,(�v , 5 STROBE CIRCUIT CABLE UP TO SECOND FLOOR VOICE CIRCUIT CABs .F UP TO SECOND FLOOR DATA LOOP UP TO SECOND FLOOR DEVICIES UP FROM FIRST, FLOOR BOOSTER POWER SUPPLY DOWN TO TENANT FIRE ALARM JUNCTION BOX RE REV. BY: Z QQ. 'Z -DESCRIPTION PRELIM-INARY SHOP DRAWINGS SHOP . DRAWINGS- FOR SUBMITALS til l -- d n 3/14/08 60 a co M 9 ««< Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved �CALE:' 1 DRAWN BY:'.. LANDERSON DESIGNED . BY: R.VEZZANF. BATE: 4/03/08 BACKROUND PLAN PROVIDED BY: OB NUMBER: SHEET -0 l; STROBE CIRCUIT CABLE UP TO SECOND FLOOR VOICE CIRCUIT CABLE UP TO SECOND FLOOR DATA LOOP UP TO SECOND FLOOR DEVICIES UP FROM FIRST FLOOR BOOSTER POWER SUPPLY DOWN TO TENANT FIRE ALARM JUNCTION BOX DRAWN. BY: 1.ANDERSON DESIGNED BY: R.VEZZANI DATE: 4/03/08 BACKROUND PLAN PROVIDED BY: OB NUMBER: SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 758 SOUTHCENTER MALL ASSOCIATED PERMITS 18-F-040 16-F-157 08-F-108 18-S-051 08-S-070 08-H-235 SITE LOCATION CITY OF TUICWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted far plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address:_755 Sooth C'aae1 Mal a l Tenant Name: V e,yS Property Owner's Name: / WeStile\A.YY y" (b . Mailing Address: 250D sOviii fyth Mal) la.1) ��C i% 1a , wA City State bp Suite Number: Floor. New Tenant? ❑ - Yes ❑ - No CONTACT PERSON-if there are questions about the submittal. ,/ Name: �i (� j � >1 � � Day Telephone: ' /?S ye/gate Company Name: CAT u% 'i ) »ol-e C1101 , ) Yl G Mailing Address: E-mail Address: 110 SIP 6 9. �. , 10 City State Zip Fax Number. Contractor's City of Tukwila NICE' III number: q7 . Business License number ' 0 4'95$-/7 Total number of new/relocated devices or sprinlder heads: 3 Valuation of Project (contractor's bid price): S 31 WD Scope of Work (please provide detailed information): .;)1 \n 3 nettcSl erd Y4DCa4C. _3 heads PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested m writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: ueSS/ct ,'4 /n 6 &)--) Plan Permit App.doc 8t22/14 Date: Day Telephone: ¥25 4-/F-/ • 71( j TFDFPForm 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: ' 4 1 -WO Site Address: 1 * )k-WtAtU QC.lrle--WC9 Suite Number: Floor:' J...k r) Tenant Name: 5O>( ' l QOJrr X 1,`jron 1 New Tenant? ❑ - Yes No W Property Owner's Name: eSkce\ `L% V C `CA X Mailing Address:Q OX 1-10 epic\S i008 AGJt3 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: CLU‘ -k\us Company Name: GI i,X.A.r(\Ck'i n �L.�ii` Mailing Address: V. -MS 5� A 3 Day Telephone: x41.0 W ).4(bLAS pyx-tAke UJA- City State Zip E-mail Address trJll(-a,ka i axY •wvvi Fax Number: Contractor's City of Tukwil l /� NICET III number: Business License number: U.PS-2)<-) Total number of new/relocated devices or sprinklerrheeaP-SD heads: ('')� Valuation of Project (contractor's bid price): $ �Y,�`) . Scope of Work (please provide detailed information):\\t v LC6 tV CCS C .\OssfY\ ` \ 5 \ \-‘o(1 PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: I C Print Name: (LCCA& Date: Oa I a-0 1 k Day Telephone:N o ( `o Plan Permit App.doc 8/22/14 TFD FP Form 8 n FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Joey's Grill 758 Southcenter Mall Permit No.: 08-H-235 Date: Mayl 29, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Nozzle heights above appliances to be per manufacturers installation guidelines. • Install splash guards between fryers and ranges/charbroilers. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Joey Restaurant 758 Southcenter Mall Permit No.: 18-S-051 Date: March 21, 2018 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Joey's 758 Southcenter Mall Permit No.: 08-S-070 Date: March 12, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. All references are NFPA 13, 2007 Edition. J Ea J For 5 March 2008 Michael Kellogg Smith Fire Systems 1106 54th Avenue East Tacoma, WA 98424 RE: Westfield Mall — Joey's Restaurant Tenant Improvement Independent Third Party Review — Fire Sprinkler System Dear Michael: Tuazon Engineering, PLLC 4322 NE r Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. It is noted that the sprinkler system modifications shown are to Zone T4 fed from the East Riser Room. The following was reviewed: • Fire Sprinkler Drawings — Sheets 1 and 2 dated 2/25/08 • Hydraulic Calculations dated 2/25/08 The documents were reviewed for compliance with the 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. The 2007 edition of NFPA 13 is the adopted standard in the City of Tukwila per Ordinance 2050, Section 16.42.020. The drawings and calculations currently reference the 2002 edition. 2. Ensure the dry pendent sprinklers in the cooler/freezers are of sufficient length to prevent freezing of the water filled branchline piping and the space around the barrel is sealed in accordance with 2007 NFPA 13 Para 8.4.10.1 and 8.4.10.2. 3. Hydraulic calculations indicate the coverage per sprinkler is 130 SF, which would correspond to 19.5 GPM minimum for a 0.15 GPM/SF density for Ordinary Hazard I (restaurant occupancy). However, the Summary of Sprinkler Outflows in the calculations show numerous sprinklers flowing less than 19.5 GPM. If the actual coverage area per sprinkler is being used to determine the minimum sprinkler discharge, the areas should be indicated in the calculations. Otherwise, it is recommended the calculations be revised for 19.5 GPM minimum flow per sprinkler. 4. Hydraulic calculations indicate 1-1/2 inch diameter branchlines with ID = 1.754" (Superflow piping). However, the shell/core sprinkler system by Western States Fire Protection installed schedule 40 branchlines with ID = 1.61". Assuming the shell/core branchlines are being reused, the inside diameter of all branchlines should be revised to reflect schedule 40 piping with ID = 1.61". 5. Hydraulic calculations indicate existing 4 inch diameter feedmain piping with ID = 4.316" (Superflow piping). Shell/core sprinkler system drawings and calculations indicate schedule 10 piping was installed. The calculations should be revised to indicate ID = 4.26". 6. The hydraulic calculations do not include all the riser room and underground piping to the connection to the water supply. The calculations should be revised to include the following piping, as taken from the shell/core hydraulic calculations by Western States Fire Protection (1st Level, Zone T4): a. 8" riser room piping with ID = 8.326, C=120, and 27'-9" equivalent length (includes fittings) b. 10" riser room piping with ID = 10.20, C=120, and 124'-1" equivalent length (includes fittings, except BFP) Westfield Mall — Joey's Restaurant Third Party Review — Fire Sprinkler Systems 5 March 2008 Page 2 c. 10" Wilkins 350 backflow preventer (see attached data sheet for friction loss chart) d. 10" underground piping with ID =10.400, C=140, and 246'-6" equivalent length (includes fittings) A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or eric@tuazon.com with any questions regarding this review. Respectfully, TUAZON ENGINEERING, PLLC zu.L., Eric P. Tuazon, PE Fire Protection Engineer C Corm, FIsMOS Prcre.2008 11 Smoh Fre S)abmt'Nbtlitltl JoeysY6nni08lam aMr1Er reviwvJcc GUARDIAN SECURITY Seattle • Tacoma • Poulsbo • Bellingham MFG. Joey's 758 southcenter mall tukwila, wa 98188 Fire Alarm System Submittal MODEL# DESCRIPTION [FIRE ALARM DEVICES] SIEMENS HTRI-R Interface module w/ relay SIEMENS HCP Control point module SIEMENS HFP-11 Smoke Detector SIEMENS AD2-P w/ Duct Smoke detector TSM -1 Module SIEMENS SET -MC -CW Ceiling Mount Speaker/Strobe SIEMENS ZR -MC -CW Ceiling Mount Strobe 1743 First Avenue South Seattle, WA 98134 Tel: 206.622.6545 Fax: 206.341, 9928 April,4 2008 GUARD/AN Customer LIFE AND PROPER MARINERS TEAM STORE 852 SOUTHCENTER MALL T' 'KWILA, WA 98188 Project MARINERS TEAM STORE Project # SECURITY r Y PROTECTION List of Materials Vendor Guardian Security Systems Inc 1743 1st Ave. South Seattle, WA 98134 Phone #: (206)622-6545 Fax #: (206)628-4990 Type of Equipment FIRE ALARM Date: Jan,22,09 Item Qty. Manuf. Model Description Unit Pri Total Price 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) t0) 21) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) 33) 34) 35) 36) 37) 38) 39) 40) 41) 42) 43) 44) 45) 46) 47) 48) 49) 50) Siemens PAD -3 Siemens AD2-P Siemens HTRI-D Siemens HTRI-R Siemens ZH CW,W Siemens ZR-MC-W,W Power Supply for Strobes with Standby** Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 Supervised Addressable Input Module Supervised Addressable Output Relay Module Interior Audible Horn Strobe Annunciator Interior Visual Strobe Annunciator Conduit Systems: All smoke removal and detection and control devices in an approved metallic raceway and all devices in conduit per Standard fIZDfl £flGI taction/ Code Corautting 5 March 2008 Michael Kellogg Smith Fire Systems 1106 54th Avenue East Tacoma, WA 98424 RE: Westfield Mall — Joey's Restaurant Tenant Improvement Independent Third Party Review — Fire Sprinkler System Dear Michael: Tuazon Engineering, PLLC 4322 NE 7 Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. It is noted that the sprinkler system modifications shown are to Zone T4 fed from the East Riser Room. The following was reviewed: • Fire Sprinkler Drawings — Sheets 1 and 2 dated 2/25108 • Hydraulic Calculations dated 2/25/08 The documents were reviewed for compliance with the 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. The 2007 edition of NFPA 13 is the adopted standard in the City of Tukwila per Ordinance 2050, Section 16.42.020. The drawings and calculations currently reference the 2002 edition. 2. Ensure the dry pendent sprinklers in the cooler/freezers are of sufficient length to prevent freezing of the water filled branchline piping and the space around the barrel is sealed in accordance with 2007 NFPA 13 Para 8.4.10.1 and 8.4.10.2. 3. Hydraulic calculations indicate the coverage per sprinkler is 130 SF, which would correspond to 19.5 GPM minimum for a 0.15 GPM/SF density for Ordinary Hazard I (restaurant occupancy). However, the Summary of Sprinkler Outflows in the calculations show numerous sprinklers flowing less than 19.5 GPM. If the actual coverage area per sprinkler is being used to determine the minimum sprinkler discharge, the areas should be indicated in the calculations. Otherwise, it is recommended the calculations be revised for 19.5 GPM minimum flow per sprinkler. 4. Hydraulic calculations indicate 1-1/2 inch diameter branchlines with ID = 1.754" (Superflow piping). However, the shellcore sprinkler system by Westem States Fire Protection installed schedule 40 branchlines with ID = 1.61". Assuming the shell/core branchlines are being reused, the inside diameter of all branchlines should be revised to reflect schedule 40 piping with ID = 1.61". 5. Hydraulic calculations indicate existing 4 inch diameter feedmain piping with ID = 4.316" (Superflow piping). Shell/core sprinkler system drawings and calculations indicate schedule 10 piping was installed. The calculations should be revised to indicate ID = 4.26". 6. The hydraulic calculations do not include all the riser room and underground piping to the connection to the water supply. The calculations should be revised to include the following piping, as taken from the shell/core hydraulic calculations by Western States Fire Protection (1st Level, Zone T4): a. 8" riser room piping with ID = 8.326, C=120, and 27'-9" equivalent length (includes fittings) b. 10" riser room piping with ID =10.20, C=120, and 124'-1" equivalent length (includes fittings, except BFP) 1 Westfield Mall — Joey's Restaurant Third Party Review — Fire Sprinkler Systems 5 March 2008 Page 2 c. 10" Wilkins 350 backflow preventer (see attached data sheet for friction loss chart) d. 10" underground piping with ID =10.400, C=140, and 246'-6" equivalent length (includes fittings) A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or eric(a�tuazon.com with any questions regarding this review. Respectfully, TUAZON ENGINEERING, PLLC 5,46 Eric P. Tuazon, PE Fire Protection Engineer C Carpry Flets12C05 Nods= 11 Smite Fn *Awns • Wasifid Jon/1;05 M penin *wider moon Jtc SMITH FIRE SYSTEMS, INC. JOB NO. T18023 JOEYS - SOUTHCENTER SYSTEM # 1 ENTRY CANOPY (3) DRY HSW ECOH AUXILIARY HYDRAULIC CALCULATION DESIGN DENSITY: 0.15 GPM / 375 SQ. FT. SYSTEM DEMAND AT BASE OF RISER 118.46 GPM AT 22.73 PSI SUBMITTAL SERIAL NO:2244HY1 03-12-2008 PAGE 1 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 AUXILIARY AREA: 3 DRY HSW ECOH IN FRONT CANOPY DENSITY: 0.15 OVER THE ENTIRE AREA FILENAME: TI8023EC FLOW TEST RESULTS Water Supply STATIC 140.00 PSI RESIDUAL 20.00 PSI @ 10900.00 GPM CITY PRESSURE AVAILABLE AT 368.5 GPM 139.77 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 201 202 203 39.55 38.00 40.91 38.00 38.00 38.00 11.20 11.20 11.20 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 4 OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 53 TO 203 12.47 11.51 13.34 118.46 GPM 100.00 GPM 150.00 GPM 368.46 GPM 34.19 PSI 0.00 PSI 15.19 FPS SUBMITTAL SERIAL NO:2244HY1 03-12-2008 PAGE 2 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 AUXILIARY AREA: 3 DRY HSW ECOH IN FRONT CANOPY DENSITY: 0.15 OVER THE ENTIRE AREA FILENAME: TI8023EC Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 52 202 1.049 L 7.00 C=120 PT 11.51 (202) Q 38.00 F=4E/T F 13.00 PE -1.30 DR1 T 20.00 0.4267 PF 8.53 12 52 1.754 L 66.00 C=120 PT 18.74 ( 52) Q 38.00 F=T,2E F 24.00 PE 0.00 BN1 T 90.00 0.0349 PF 3.14 PT 21.88 ( 12) 53 203 13 53 Q 40.91 Q 40.91 51 201 11 51 Q 39.55 Q 39.55 1.049 L 3.75 C=120 PT 13.34 (203) F=2E/T F 9.00 PE -1.30 DRI T 12.75 0.4891 PF 6.24 1.754 L 66.00 C=120 PT 18.28 ( 53) F=T,2E F 24.00 PE 0.00 BN1 T 90.00 0.0400 PF 3.60 PT 21.88 ( 13) 1.049 L 7.00 C=120 PT 12.47 (201) F=2E/T F 9.00 PE -1.30 DR1 T 16.00 0.4594 PF 7.35 1.754 L 66.00 C=120 PT 18.52 ( 51) F=T,2E F 24.00 PE 0.00 BN1 T 90.00 0.0376 PF 3.38 PT 21.90 ( 11) 12 13 4.260 L 10.00 C=120 PT 21.88 ( 13) Q 40.91 F=0 F 0.00 PE 0.00 FM2 T 10.00 0.0005 PF 0.01 11 12DQ 38.00 4.260 L 9.42 C=120 PT 21.89 ( 12) Q 78.91 F=0 F 0.00 PE 0.00 FM2 T 9.42 0.0018 PF 0.02 20 11DQ 39.55 4.260 L 24.00 C=120 PT 21.91 ( 11) Q 118.46 F=T F 26.00 PE 0.00 FM2 T 50.00 0.0038 PF 0.19 10 20 4.260 L 57.00 C=120 PT 22.10 ( 20) Q 118.46 F=4E,EE F 57.00 PE 0.20 FM1 T 114.00 0.0038 PF 0.43 4 10 4.260 L 11.50 C=120 PT 22.73 ( 10) Q 118.46 F=T,BFY,CV F 65.00 PE 4.98 FR1 T 76.50 0.0038 PF 0.29 COMMENT: 100 GPM ADDED FOR INSIDE HOSE ALLOWANCE SUBMITTAL SERIAL NO:2244HY1 03-12-2008 PAGE 3 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 AUXILIARY AREA: 3 DRY HSW ECOH IN FRONT CANOPY DENSITY: 0.15 OVER THE ENTIRE AREA FILENAME: TI8023EC Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 3 4DQ 100.00 8.249 L 27.75 C=120 PT 28.00 ( 4) Q 218.46 F=0 F 0.00 PE 0.00 FR2 T 27.75 0.0005 PF 0.01 2 3 10.200 L 124.08 C=120 PT 28.01 ( 3) Q 218.46 F=0 F 0.00 PE 0.00 FR1 T 124.08 0.0002 PF 0.02 1 2 10.000 L 0.01 C=120 PT 28.03 ( 2) Q 218.46 F=DD1 F 0.00 PE 0.00 MA1 T 0.01 0.0002 PF 0.00 10" WILKINS 350DA 6.12 0 1 10.275 L 246.50 C=140 PT 34.15 ( 1) Q 218.46 F=0 F 0.00 PE 0.00 UN1 T 246.50 0.0001 PF 0.02 PT 34.17 ( 0) SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East • Tacoma, Washington 98424 (253) 926-1880 • FAX (253) 926-2350 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME JOEYS - SOUTHCENTER JOB NO. TI8023 DATE 3/6/08 ADDRESS t5-(--633' SOUTHCENTER PKWY BY M. KELLOGG TUKWILA, WASHINGTON 98188 SYSTEM DESIGNATION: WET SYSTEM 1 HAZARD DESCRIPTION: RESTUARANT HAZARD CLASS PER NFPA 13 : (2007) ORDINARY HAZARD GROUP 1 SPECIFIC RULING: RULING MADE BY: OF DENSITY: 0.15 GPM OVER THE MOST HYDRAULICALLY REMOTE 1500 SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: INSIDE HOSE 100 GPM OUTSIDE HOSE IN -RACK SPRINKLER DEMAND SYSTEM TYPE: WET "C" FACTOR OVERHEAD : 120 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: SPRINKLER MANUFACTURER: RELIABLE MODEL: K -FACTOR: 150 GPM GPM ADDED AT: NODE 4 NODE 0 TOTAL NUMBER OF SPRINKLERS THIS SYSTEM "C" FACTOR UNDERGROUND : 140 130 SQUARE FEET G4A TEMPERATURE: 155 ° F 5.6 ORIFICE SIZE: 1/2" 115 WATER SUPPLY: STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM ELEVATION OF TEST: SITE DATE OF TEST: DATA PROVIDED BY: LOCATION OF TEST: SITE WSFP PLANS OF EXISTING SHELL SYSTEM BASE OF RISER DEMAND 478.55 GPM REQUIRED AT 46.15 PSI (INCLUDING 100 GPM FOR HOSE STREAMS) SUMMARY 628.55 GPM REQUIRED AT 51.69 PSI AT CONNECTION TO CITY MAIN (INCLUDING 250 GPM FOR TOTAL HOSE STREAMS) • EYS SOUTH BRLICANIMAgiffiE z cc m 0 o O D 0) z 0 z a C. • UTHEAST CORNER OF RE TA : _ 1 t ii 1!a �, N Iii11111111111111111111111 ::�HH iNN_■■_■_■■iaii -------------u~iU u~i W W WO Z aO= 2 O � 11111111111 G o 111111 IIIIIIIIIIIIIHIHHIIIIIIIIHHHIIIIHIIIUIIIIIIHIIHIIHI a0 D g 0 1 o• w IHI1llhIOIHOHHHHOHiftHIKh1IIifflHffHin 2 • II■ ■■■■■■■■■■■■■■■■N■■■■■■■■■H■■■■■■■■/■■■■■■■■■■■■■■■■■■■■H� cd 0 N N Z `� v II. IIOIIIIIl!I1IIIIH IUII!flhIIIIIAhhIIAhIIIHhIlI N II■ ■■ ■■ ■ III�■N ■■■ ■■■H■■■■■iiiuii1 -, 1111-111 - I VIII ill 11 l IIIYII ul IIINlllblllllhIl 1 I1IIIlluIl1Hh 1 IIIUII i IIHLI HIII lIIUIIlII■IIIIIIi1111II11HIQ1IIII!IWI i /1IHIII//ii11i 11IHilHi Norm iiihiilHllHiilHiil1Hll!Hillhill ilii 1 lH II 1 1 ! i11H1111111 111 IIHIIIHIIIHII 1111111111111111 11111111 II1llII1llUlIlUlI11 i1HiliHilliH 1 1 III :I VIII IMO MEM HHHHIIIIHIIIIIIIIHIIIHHHIHII 1111111111111111 111111 IIAIIINi111111111111111111Ih1 IHIHIIIIIIIIHIIIIi11111HH IuhIIohIrIII111 IHIHIIIIIOIIIKIIIIIHUII uIUhIuuI[LI 11111 � Q , Illlllllli n :. 0 1 a. v0__1›. , II- uR. II uuuuuuiniHiiiF�iJIIiii■u uu.nuu.uuh■Nu. N co _ w J j ��j �f lF1LI11hllh11I11lKh1Il co cc LL < a 111± j f!}■ ■ ■■■ ■■■ _■ ■ ■■■ ■■ ■■N■■■ �►`\■■■■N■■■■■■■■■■ •ililiilm o01-�l IH 11111114111110 lllllillililii 11111 r llN!!!lhlhIHl 11111! lli1YHlhlii!®i 11111 l!illhiilhIil N■■■■■/■■ ■■■■■■ ■ ■H■■ ■ ■ ■■■■■■■■.■/■■■■H■■H■■■■N■■■■■■■■\`\■■NH■■■■/■ iiiiiiiiliiiiii HiihHi 1110 iliihIIHhIHHHi111PMEOhHihIIIOUIIMii 4 IIIIIhhhilhhhII IIIIIhlIilHihhhN111111111111lH111t1i11111111H1HII11illlllllillI1b 11111,,1Ii1111l1., o IIA1 1A1 1111111:-1 - 11�l1 1111. ��. _ �, ,., Q- a ;141-1-1-#911Z2 ISd NI 31:if1SS3Hd o, NX 0 z w 2 J 0 CO SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 1 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 FLOW TEST RESULTS Water Supply STATIC 140.00 PSI RESIDUAL 20.00 PSI @ 10900.00 GPM CITY PRESSURE AVAILABLE AT 628.6 GPM 139.39 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 101 26.58 19.50 5.60 22.53 102 26.51 19.50 5.60 22.40 103 21.99 19.50 5.60 15.42 104 20.81 19.50 5.60 13.81 105 20.05 19.50 5.60 12.81 106 19.73 19.50 5.60 12.41 107 19.58 19.50 5.60 12.22 108 19.50 19.50 5.60 12.13 109 23.04 19.50 5.60 16.92 110 22.18 19.50 5.60 15.68 111 21.64 19.50 5.60 14.93 112 21.34 19.50 5.60 14.52 113 21.25 19.50 5.60 14.41 114 24.18 19.50 5.60 18.64 115 23.63 19.50 5.60 17.80 116 23.31 19.50 5.60 17.33 117 23.25 19.50 5.60 17.24 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 4 OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 22 TO 33 378.55 GPM 100.00 GPM 150.00 GPM 628.55 GPM 51.69 PSI 0.00 PSI 16.15 FPS SUBMITTAL SERIAL N0:2244HY1 03-06-2008 PAGE 2 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 Location Flow Pipe Fittings Equiv Friction, Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 38 108 1.049 L 31.00 C=120 PT 12.13 (108) Q 19.50 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1242 PF 4.72 37 38 1.754 L 13.00 C=120 PT 15.55 ( 38) Q 19.50 F=0 F 0.00 PE 0.00 BN1 T 13.00 0.0102 PF 0.13 PT 15.68 ( 37) 47 117 1.049 L 31.00 C=120 PT 17.24 (117) Q 23.25 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1720 PF 6.54 46 47 1.754 L 8.50 C=120 PT 22.48 ( 47) Q 23.25 F=0 F 0.00 PE 0.00 BN1 T 8.50 0.0141 PF 0.12 PT 22.60 ( 46) 46 116 1.049 L 31.00 C=120 PT 17.33 (116) Q 23.31 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1728 PF 6.57 45 46DQ 23.25 1.754 L 12.50 C=120 PT 22.60 ( 46) Q 46.56 F=0 F 0.00 PE 0.00 BN1 T 12.50 0.0508 PF 0.63 PT 23.23 ( 45) 45 115 1.049 L 31.00 C=120 PT 17.80 (115) Q 23.63 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1771 PF 6.73 44 45DQ 46.56 1.754 L 10.50 C=120 PT 23.23 ( 45) Q 70.19 F=0 F 0.00 PE 0.00 BN1 T 10.50 0.1086 PF 1.14 PT 24.37 ( 44) 44 114 1.049 L 31.00 C=120 PT 18.64 (114) Q 24.18 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1849 PF 7.03 24 44DQ 70.19 1.754 Q 94.37 BN1 L 15.67 C=120 PT 24.37 ( 44) F=T,2E F 24.00 PE 0.00 T 39.67 0.1878 PF 7.45 SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 3 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 23 24 4.260 L 10.00 C=120 PT 31.82 ( 24) Q 94.37 F=0 F 0.00 PE 0.00 NC1 T 10.00 0.0025 PF 0.02 PT 31.84 ( 23) 43 113 1.049 L 31.00 C=120 PT 14.41 (113) Q 21.25 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1456 PF 5.53 42 43 1.754 L 13.00 C=120 PT 18.64 ( 43) Q 21.25 F=0 F 0.00 PE 0.00 BN1 T 13.00 0.0119 PF 0.15 PT 18.79 ( 42) 42 112 1.049 L 31.00 C=120 PT 14.52 (112) Q 21.34 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1467 PF 5.57 41 42DQ 21.25 1.754 L 13.00 C=120 PT 18.79 ( 42) Q 42.59 F=0 F 0.00 PE 0.00 BN1 T 13.00 0.0431 PF 0.56 PT 19.35 ( 41) 41 111 1.049 L 31.00 C=120 PT 14.93 (111) Q 21.64 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1506 PF 5.72 40 41DQ 42.59 1.754 L 11.00 C=120 PT 19.35 ( 41) Q 64.23 F=0 F 0.00 PE 0.00 BN1 T 11.00 0.0922 PF 1.01 PT 20.36 ( 40) 40 110 1.049 L 31.00 C=120 PT 15.68 (110) Q 22.18 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1575 PF 5.98 39 40DQ 64.23 1.754 L 10.50 C=120 PT 20.36 ( 40) Q 86.41 F=0 F 0.00 PE 0.00 BN1 T 10.50 0.1595 PF 1.67 PT 22.03 ( 39) 39 109 1.049 L 31.00 C=120 PT 16.92 (109) Q 23.04 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1690 PF 6.42 SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 4 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 23 39DQ 86.41 1.754 L 15.67 C=120 PT 22.04 ( 39) Q 109.45 F=T,2E F 24.00 PE 0.00 BN1 T 39.67 0.2470 PF 9.80 22 23DQ 94.37 4.260 L 7.92 C=120 PT 31.84 ( 23) Q 203.82 F=0 F 0.00 PE 0.00 NC1 T 7.92 0.0104 PF 0.08 PT 31.92 ( 22) 37 107 1.049 L 31.00 C=120 PT 12.22 (107) Q 19.58 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1251 PF 4.75 36 37DQ 19.50 1.754 L 7.00 C=120 PT 15.67 ( 37) Q 39.08 F=0 F 0.00 PE 0.00 BN1 T 7.00 0.0368 PF 0.26 PT 15.93 ( 36) 36 106 1.049 L 31.00 C=120 PT 12.41 (106) Q 19.73 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1269 PF 4.82 35 36DQ 39.08 1.754 L 7.00 C=120 PT 15.93 ( 36) Q 58.81 F=0 F 0.00 PE 0.00 BN1 T 7.00 0.0783 PF 0.55 PT 16.48 ( 35) 35 105 1.049 L 31.00 C=120 PT 12.81 (105) Q 20.05 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1307 PF 4.97 34 35DQ 58.81 1.754 L 10.00 C=120 PT 16.48 ( 35) Q 78.85 F=0 F 0.00 PE 0.00 BN1 T 10.00 0.1347 PF 1.35 PT 17.83 ( 34) 34 104 1.049 L 31.00 C=120 PT 13.81 (104) Q 20.81 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1400 PF 5.32 33 34DQ 78.85 1.754 L 10.50 C=120 PT 17.83 ( 34) Q 99.66 F=0 F 0.00 PE 0.00 BN1 T 10.50 0.2077 PF 2.18 PT 20.01 ( 33) SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 5 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 33 103 1.049 L 31.00 C=120 PT 15.42 (103) Q 21.99 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.1551 PF 5.89 22 33DQ 99.66 1.754 L 15.67 C=120 PT 20.01 ( 33) Q 121.65 F=T,2E F 24.00 PE 0.00 BN1 T 39.67 0.3004 PF 11.92 21 22DQ 203.82 4.260 L 10.00 C=120 PT 31.93 ( 22) Q 325.47 F=0 F 0.00 PE 0.00 NC1 T 10.00 0.0246 PF 0.25 PT 32.18 ( 21) 32 102 1.049 L 31.00 C=120 PT 22.40 (102) Q 26.51 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.2191 PF 8.33 31 32 1.754 L 9.50 C=120 PT 29.43 ( 32) Q 26.51 F=0 F 0.00 PE 0.00 BN1 T 9.50 0.0179 PF 0.17 PT 29.60 ( 31) 31 101 1.049 L 31.00 C=120 PT 22.53 (101) Q 26.58 F=T,E F 7.00 PE -1.30 DR1 T 38.00 0.2203 PF 8.37 21 31DQ 26.51 1.754 L 15.67 C=120 PT 29.60 ( 31) Q 53.09 F=T,2E F 24.00 PE 0.00 BN1 T 39.67 0.0648 PF 2.57 20 21DQ 325.47 4.260 L 53.42 C=120 PT 32.17 ( 21) Q 378.55 F=T F 26.00 PE 0.00 FM2 T 79.42 0.0326 PF 2.59 10 20 4.260 L 57.00 C=120 PT 34.76 ( 20) Q 378.55 F=4E,EE F 57.00 PE 0.20 FM1 T 114.00 0.0326 PF 3.72 4 10 4.260 L 11.50 C=120 PT 38.68 ( 10) Q 378.55 F=T,BFY,CV F 65.00 PE 4.98 FR1 T 76.50 0.0326 PF 2.49 COMMENT: 100 GPM ADDED FOR INSIDE HOSE ALLOWANCE SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 6 JOEYS SOUTHCENTER TI SFS JOB NUMBER: TI8023 MOST DEMANDING AREA: SOUTHEAST CORNER OF RESTAURANT DENSITY: 0.15 GPM OVER 1500 SQUARE FEET FILENAME: TI8023 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 3 4DQ 100.00 8.249 L 27.75 C=120 PT 46.15 ( 4) Q 478.55 F=0 F 0.00 PE 0.00 FR2 T 27.75 0.0020 PF 0.06 2 3 10.200 L 124.08 C=120 PT 46.21 ( 3) Q 478.55 F=0 F 0.00 PE 0.00 FR1 T 124.08 0.0007 PF 0.09 1 2 10.000 L 0.01 C=120 PT 46.30 ( 2) Q 478.55 F=DD1 F 0.00 PE 0.00 MA1 T 0.01 0.0008 PF 0.00 10" WILKINS 350DA 5.27 0 1 10.275 Q 478.55 UN1 L 246.50 C=140 PT 51.57 ( 1) F=0 F 0.00 PE 0.00 T 246.50 0.0005 PF 0.12 PT 51.69 ( 0) I I FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUM3ESHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FI ALARM SYSTEM PJ,N c -P ED SHEET INDEX - Without Comments p As Not -F.%6 in Red p Pea The Attached Letter These plans ha''t_ be,!.: :; ': aed 'hv The Tukwila Fire Pre'v'ention Buren: '. rare with current City standards. Acr_ ,, . 2 . "j = s� i. ors and omissions whicil ' } :.. ; { . ..' )ns of adopted _andards anu , ,�.t :,:,r;.:. ,;1'`t:� for the quacy of aeric ; ".a :iewlgi ler. :alae ......._.. ... . ;'?tuitions, ir3 winqS after this date MI �"W __ L''? 'tr �eotar. l� require a resubmittal e . , '. ` . <a approval. Final acceptaliCe s : a+. r.,leci. tt)11e test and inspection by The Tukwila Fire~ Prevention Bureau. ^^ Date: -3 By. S I WI NOn A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testino SCHEDULE A\D CO\SUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPLJFPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKED V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END TUKWILA FIRE DEPART HENT Please calls 206-575-4407 and give this Fire Permit No. 1(P -r IS -7 and exact address for shut- down or rest+.ortien approval. FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSDCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT EE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVCE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDJIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SI -ALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MININUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX EX EX 1 EX EX EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS EX REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD -3 -ENOL 66" A.F.F. TO TOP ®DEX DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM EX DUCT DETECTOR TEST SWITCH (EXISTING) TSM- 1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE EX WITH RELAY (EXISTING) HTRI-R SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM -4 N STROBE (NEW) ZR -MC -CW SIEMENS 4S BOX CEILING FIRE ALARM EX STROBE (EXISTING) ZH-MC-CW SIEMENS 4S BOX CEILING 3EX FIRE ALARM HORN STROBE (EXISTING) ZH-MC-CW SIEMENS 4S BOX CEILING 8EX FIRE ALARM HORN STROBE (EXISTING) ZH-MC-W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS i.275sf BOXLUNCH SPACE #652 / STORE #4530 j macys - LEVELS _50.407sf as3 x0� IvEreaM, vwP,ESS Ascxouy.= • 1 • RR FEN E4 F i tr� o ° II <. w [1.1:.171=, r1 SEARS TR A`3wra L:UARA.Wa 0 R-rH..vr PATH 'cJ Pam JCPenney PAID ``ne12016 TUKWILA FIRE 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 2 0 DESCRIPTION SHOP DRAWINGS DATE M N. 0 <aaa< 0 co Lc) 1 cc 0 L.. 0j CO 0 co T ~ NC) "7" z 'Qom° G- w< cLz D (DI CO aW� CCW LL U II- 0 • imam 0 z 111 0) (11) �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:07/13/1 6 BACKROUND PLAN PROVIDED BY: .0B NUMBER:17025-1} SHEET WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All. Rights Reserved FA -01 } THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ —7 DEDICATED EMERGENCY 111 TUBE OUTLET--\ SAMPLING TUBE INLET— SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL N01E FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. *CONTACT RARNGS 4.014 0 125VAC 4.0A 0 30VDC MINsHoRWIANGB TO NEXT ADDRESSABLE (+ DEVICE STOP W LAST DEVICE FROM XLS CONTROL PANEL (+ DR PREVIOUS ADDRESSABLE DEVICE — O O � GROU1 1-11 ar u 1 4 HTRI—R 0 O O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE LJLJLi ORD N L O X O PAD -3 0 00 INPUT INPUT TROUBLE MCI NAC2 NAC NAC4 AUX + – 1 2+ 2– 2 NC C NO + – + – + – + – + – _Iuuuu 0 3.6k EOL 0 2 0 0 I O let (—) (+) , NAC 4 CIRCUIT NAC 3 CIRCUIT NAC 2 CIRCUIT CEILIN TILE oO 00 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (—) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE 1+ O (+) FROM XLS CONTROL PANEL OR i+ PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH -- h GROUND B 0 -o Li) HTRI—R OSTATUS LED CO 0 N.O. 0 COM m N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O MUSIC u v HORN/STROBE OR STROBE ONLY 0 HORN/STROBE OR STROBE ONLY 1 HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL L} -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATINc TEMPERATIIRE: +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —. FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > DATA IN (+) > TO NEXT DEVICE OR END OF LINE DEVICE IS LISTED FOR AIR VOLOCIIY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (—) > TO NEXT 1 1 . ADDRESSABLE DEVICE (+) SMOKE DETECTOR WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE TB1 ®® NO COM NC 0 ? TO FAN SHUTDOWN 470 SWITCH + INPUT LED TSM -1 TONEXT ADDRESSABLE DEVICE 0 a NO® COM B HTRI-R NC B TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX TO NEXT DEVICE JUNCTION BOX MOUNTED AGAINS CEILING SUPPORT SMOKE DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS (REV. BY: C0 m 0 DESCRIPTION SHOP DRAWINGS DATE L0 c M , 0 2<<<<< U z J O 0 cc NG AND MOUTN CC J U /;CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07/ 13/ 1 6 BACKROUND PLAN PROVIDED BY: \ OB NUMBER:17025-1} SHEET FA -02 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved \, A B C D E F G H I J K FIRE ALARM BOOSTER Project: BOXLUNCH Panel: EXISTING PAD -3 BOOSTER Date: July 13, 2016 Module/Device POWER POWER Qty SUPPLY SUPPLY Standby (mA) BATTERY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 30 30 0 30 30 0 TOTAL FIRE ALARM POWER SUPPLY 30 30 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 622 Total(A)= 30 Total(B)= 652 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 30 652 Total current ratings converted to amperes (line D x .001) 0.03 0.652 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.72 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.0543116 Add lines G and I Total Standby and Alarm AH 0.7743116 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.92917392 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: BOXLUNCH Panel: EXISTING PAD -3 BOOSTER POWER SUPPLY Date: July 13, 2016 Wire Resistance 2.58 CURRENT TOTAL= 622.00 ZH-MC-CW @l5cd 2 ZH-MC-CW @30cd 1 /J -1 -MC -CW @75cd ZH-MC-CW @95cd 2 ZR -MC -CW @l5cd ZR -MC -CW @30cd DEVICES 5 87 131 222 292 69 111 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 0 262 222 0 138 622 14 289 23.07 (WL*2)*(R/ft) (Total Cct Load) (E= I * R) 24 - E) 622 1.49 0.62 0.93 23.07 CALCULATIONS TO NEAREST EXISTING POWER SUPPLY (TENANT J -BOX) TO NEAREST EXISTING DATA LOOP J S1-1 51-2 30cd 15cd SINGLE LINE DIAGRAM EX D D,I_y HT -R 214 I TSM EX EX S1-3 S1-4 S1-5 15cd 75cd 30cd 004. rr) co 0\ ASH INGTON 1743 IST AVE. SO., SEATTLE, FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE (0 M N. 0 0 0 coLU z w cc z�c UJ 0 03 T HNA = 0 *z 0 < (1) o Z w Q_z D cn = J JQ x2< z Ocr 2 O mQWg 1= ZY _ w� LL 01- D 2 J 0 .� M `-r+ co W I -- y— /\ No -Mo DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07/13/16 BACKROUND PLAN PROVIDED BY: \0B NUMBER:17025-1} C SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved \ J TO TENANT JUNCTION BOX A AD,J.A.CENT -•:E\IANT S1-2 15cd D TO TENANT JUNCTION BOX 4 EX S1-1 30cd EX • FXISTINc":; STOC-r<ROOM N S1-3 15cd ,/// /,/ • // C s, / AL\JAC ENT TENANT s ALtAREA S1-4 75cd EX EX '.;17 CASH/ \V PA D _7„/7T , / / / / 8E,Aw_X EOL S1 S1-5 30cd Lij MAL! CORRIDOR FIRE ALARM SYSTEM PLAN Fri COMMON 2 \, 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 1REV. BY: I 0 0 DESCRIPTION SHOP DRAWINGS DATE (9 Z r, 0 2 <<<<< Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved L1.1 CC LL ‘CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 07/13/16 BACKROUND PLAN PROVIDED BY: \0B NUMBER:17025-1j 1. SHEET '\ FA -04 ,/ I (7 '7= H D 33I \ \ , A / .) SOUTHCENTER MALL \ \ L 31 I IJ 1 D HANGER LEGEND TARGET SITE PLAN 0 50 120 150 200 250 = 192 SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND CCE, TE • Wthout Comments O As Noted In Red Per The Attached Letter !nese plans have been revinfed by The Tukwila Fire Prevention Bureau for cot', cir-friai-,ce with current city standards. Acceptance -„!!_ib1 to errors and omissions whin d3 r!Cli..31..iti'ic:rize violations of adopted standards and Thzt. r,:!.3ponfiiti4;lty for the adequacy of cie!,-3n with the designer. Additions, deletions ari,:-!visions to these drawings atter this date will void thi.s.accEptance Rnd will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. [Date: 3 -0- -og By: k\-11 • - ,FSYSINITILATOcer l'fittWILA FIRE DEPARTMENT Please call: 575-440Z and give this job No. OR -S -07D and exact address for shut, down or restoration approval, REVISIONS SYM 1,1ANUFAGRI59I 5.114. TYPE MODE_ 1•41.1 Mei 0•4114.• 11146.0 1131• .70 0.0•17117 TOTAL THIS SHEET .30 805 BCD 130.1 BCP ROT CIS FO POW ORM 585 UFO MOLE FICSHED H.00R SOROS OF BEAN BOTTOM OF DEM BOTTOM CF JOST 0001018 01' IRAN sonvoi OF GOSS CUT 1083310 FELE/ ORDER ASCE FACE CIF WALL ClUISCE FN:E 08 8383). 60*31770 SPRiNCLERS UN.ESS FMB, OTHERWSE BOO 0 13 CENTERLINE OF PIPE TO REFEREhCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY MAX; LETTER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRAE LETTER INDICATES -TYPE HANGER LOCATION ELEVATION ABOVE RutEHENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO. DATE BY REASON FOR REVISION C _PS/ CONTRACT WITH GENERAL NOTES 1. ALL GROOVED COUPLINGS TO BE RIGID UNLESS NOTED (UI) WHICH ARE FLEXIBLE. 2. ALL STEEL PIPE TO BE AS FOLLOWS: STEEL PIPE ASTM A - 795 OR BETTER PIPE SUM SCHEDULE WALL THICIGNESS INTERNAL DIAMETER END PREP TYPES ALLOWED BELOW OF HAMA /FFE CAP1.11` IA ONCOG 1 40 0.133 1.049 THREADED, CUT GROOVED, ROLL GROOVED, PLAIN ENG POLISHED 2.053 0.044 1 1/4 SUP05-FID 0.059 1.542 mu. GRSOVED, POLISHED, PLAIN END (FOR SUIT WELDING) 1.817 0.097 1 12 SUPER-FLO 0.074 1.752 ROLL GROOVED. POUSHED, PLAIN 0.0 ( Fr* WIT WELDING) 2.448 0.125 2 SUPER -FW 0.074 2.227 ROLL GROOVED. POUSHED, PLAIN ENO (FOR 5117 881.0581) 3.456 0.202 2 1/2 SUPER -FW 0.074 2.727 Rom. GROOVED. PUIIN 8115 (FOR ENT YIELDING) 4.734 0.303 3 SUPER-FLO 0.074 3352 ROLL GROOVED, PIAIN END (FOR BUTT VASLING) 6.526 0.458 4 SUPEFI-FW 0.074 4.352 ROLL GFOOVED, PLAIN ENO (FOR Km sums) 9.927 0.773 5 10 0.134 5295 ROLL GROOVED. PLAN 0830 (55 COTT 'BELDING) 17.303 1.144 8 ..., 0.134 6.357 ROLL GROOVED, PLAIN END (FOR WIT VIELLING) 23.020 1.849 8 .., 0.188 8249 FOU. GROOVED, P3415 0830 (FOR BUTT ISELLIN3) 40.083 2.78 .. WALL THICKNESS PER NFPA #13 SCOPE OF WORK SMITH FIRE SYSTEMS (SFS) WILL START AT THE EXISTING 4MAIN OF THE WET PPE FIRE SPRINKLER SYSTEM AND ADD BRANCHUNES MID SPRINKLERS TO ACCOMMODATE THE NEW TENANT IMPROVEMENT. CLARIFICATIONS - ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINF_D AT A M942AUPA 40° F, BY OTHERS, TO PREVENT FREEZING. - SPRINKLERS ARE NOT NECESSARILY CENTERED IN THE CEILING TILE EXCLUSIONS - ALARM WORK OR ELECTRICAL V,IR*IG. - PROTECTION 1s1 NON-COMBUSTIBLE VOID SPACE - PROTECTION UNDER RAISED FWOR. - PROTECTION OF KITCHEN 50009 /781 E<HAUST DUCTS. DESIGN CRITERIA - PER NFPA *13 (2007 EDMON)N4D THE cny OF TUKWILA DESIGN DENSITY: 0.15 GPM / 1500 SQ. FT. PIPING / FITTING LEGEND Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 or email fireinsprequestPci.tukwila.wa.us to schedule your inspections a minimum of 48 hours in 'advance of the date you want an inspection. NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic test approval. J R A13130TT CONSTRUCTION 3512 AIRPORT WAY SOUTH SEATTLE, WASHINGTON 98134-2135 PROJECT MANAGER: JED BICKFORD PHONE : (206) 467-8500 FAX: (206) 447-1885 SUPERINTENDENT : WAYNE JACKSON PHONE : (206) 854-3853 FAX: E0STING PIPING NEW PIPING 3. ,....*404-4•41.14270', FIL 3701 5»1 PA)oi 08 1.67/5:>0 7 .51 irk SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 98424 CONTR. REG. NO. SMITHFS138:11- Bus: ( 253 ) 928 - 1880 FAX (253) 926-2350 JOEYS - SOUTHCENTER --enSOUTHCENTER PKWY /Ode TUKWILA, WASHINGTON 98188 DESIGNER DATE SHEET JOB NO. M. KELLOGG 02/25/08 1 OF 2 T18023 W18 x35 .4 1 1' 10-0 rI I- EXISTING 4• MAIN O 1 INSTALLED BY OTHERS g 24 I O z 3 7-11' 247 W 24x82 O W24 x55 .4 I I9'4i / 9'3' 170' 9'-0' / 2.0 / 5,10' x/ (I 0 EXISTING 4'MAIN 1 ' i- INSTALLED BYOIH2?S I W 24 x62 10-0' ROLL EXISTING 4• MAN INSTALLED BYOTTERS SO THAT OUTLETS ARE ON BOTTOM .4 W24 x 52 f_/:K K -W12 x14 TOT W24 x78 = 10T TOT KITCHEN HOOD N.K.S. W14x28 W 16 x 31 y II 114' .1.5 22T W12x14 HYDRAULICALLY MOST DEMANDING AREA: SYS# 1 DENSITY: 0.15 GPM OVER 1500 SQUARE FEET SYSTEM DEMAND AT BOO: 478.55 GPM AT 46.15 PSI ( INCLUDING 100 GPM FOR INSIDE HOSE STREAMS ) /"" W 12 x14 W 14026 W18x31 48T W18x26 .4? DUSTING 8' BACKFIDW INSTALLED BY OTHERS EXISTING 4• RISER INSTALLED BYOTHERS f-- EXISTING 6' HEADER INSTALLED BY OTHERS 18Kw/: W18 x28 1 HOUR MECH. SHAFT ABOVE NAS. 43} * % l0 11 ,l1 10E u *11 W24 x55 W78x28 W 14x22 HANGER LEGEND SPRINKLER LEGEND N 11I OVERHEAD SPRINKLER PLAN O 4 8 SCALE 114'=1'-0' ABBREVIATIONS SYMBOL LEGEND FITTER / LISTER NOTES 1. ATTACH NEW BRANCHLINES TO CAPPED EXISTING 1.5' SHAPE NIPPLES. 2. SEND 1' PLUGS FOR OUTLETS ON BRANCHUNES. 3. FITTER TO VERIFY CEILINGS PRIOR TO ORDERING DROPS. REVISIONS SYM WVYUFACTURER 5.1N. TYPE MODEL SEE HANGER DETALS THIS SHEET • ®1k 4 RELIABLE RELIABLE RELIABLE RELIABLE TYCO 83615 SSP FIFR 85415 CONC PEND G4A 85415 ,CONC PEND 85714 DRY PEND TY5339 DRYHSW G4A F3QR DS -3 (ECOH) CHR BRZ 8112 CHR CHR CHR CHR BLACK CHR CHR 1/2 1/2' 1/2' 1/L 11.2 K 1/2' 1/2 1/2 155' 165° 155' 288° 155° 32 81 13 8 3 TOTAL THIS SHAT 115 Al* NCO 8® B OP BOT FO 215 FON CRYN NAS VO MOMS F1i94311 R001 BOTTOM OF BEAM 801126 OF 0E0C B OTTOM 2F x1sT 801126 CF PURA BORON OF TMS4 CUr TO 910 FED MEE RACE CF AYNL 00 AUT FACE OF WA AU10LL NO .E MESS NOTED05030DEMME 12 BOD 0 —H -- CENTERLINE OF PIPE TO REFERENCED STRUCTURE N INCHES 2 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCE) POINT N FEET AND INCHES HYDRAULIC CALCULATION NGDE FL.E CELE COUPUNG RIGID COUPLING NO. DATE BY REASON FOR REVISION CONTRACT Wf 11 J R ABBOTT CONSTRUCTION 3512 AIRPORT WAY SOUTH SEATTLE, WASHINGTON 98134-2135 PROJECT MANAGER : JED BICK FORD PHONE: (206) 467.8500 FAX: (206) 447-1885 SUPERINTENDENT : WAYNE JACKSON PHONE: (206) 854.3853 FAX: HANGER DETAIL T ( r CONCRETESTEELPANDECK FLOOR ON j 36' x 33/4' KWIK BOLT -' ^ 318' RO0 COUPLNG (2-5/8' MIN. Ewe)) 3I8'x (2-10) ATR HANGER RING HANGER DETAIL 'K HIL7T 3/8' HDI DROP N ANCHOR 310' x 3-3/4' KWIK BOLT (2-58' MIN. EMBED) 318' RDD COUPLING 318'5 (2-10) ATR (2) HANGER RINGS WITH R) TOLCO FIG. 25 SURGE RESTRAINERS TOLCO FIG. 75 SWIVEL. ATTACHMENT - 3/70 (4-0) RESTRAINT ROD HANGER DETAIL 'KR' 2ND FLOOR (Ir? BRANCHI'E DROP 1'x (ROI SCH-40, MIT WITH 90' ELBOW III 1 1' ELBOW ••::•T: (1-0 ABOVE FINISHED CELLNG) SPRNIOBI FLEX DROP DETAIL 114 (4-3) SCHF40, TXT 1 I� FOAM RUBBER INSULATION FOAM -0 -RM 1' THREADED / TEE AND PWG DRY PENDENT- " A=18' COOLER CELNG DRY PENDENT DETAIL Chi 2RCATE OF DI W ETENCY /UAW KEY Pur 5F5 co 1- z 0 Lll o 0 0 SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 96424 CONTR REG. NO. SMITHFS1380T Bus: ( 253) 926-1880 FAX: ( 253) 828-2350 JOEYS - SOUTHCENTER 633 SOUTHCENTER PKWY TUKWILA, WASHINGTON 98188 DESIGNER 1 DATE M. KELLOGG 1 02/25/08 SHEET 2 OF 2 JOB NO. T18023 ,q I > - ' 110-0' 1 C' C— n ��® Los - 2 1 '7 4T 2, n 1 1120'1 rc I ®� Ic "", 108 °� —E_ m q - W27 x84 ,' / W18x31 48T W18x26 .4? DUSTING 8' BACKFIDW INSTALLED BY OTHERS EXISTING 4• RISER INSTALLED BYOTHERS f-- EXISTING 6' HEADER INSTALLED BY OTHERS 18Kw/: W18 x28 1 HOUR MECH. SHAFT ABOVE NAS. 43} * % l0 11 ,l1 10E u *11 W24 x55 W78x28 W 14x22 HANGER LEGEND SPRINKLER LEGEND N 11I OVERHEAD SPRINKLER PLAN O 4 8 SCALE 114'=1'-0' ABBREVIATIONS SYMBOL LEGEND FITTER / LISTER NOTES 1. ATTACH NEW BRANCHLINES TO CAPPED EXISTING 1.5' SHAPE NIPPLES. 2. SEND 1' PLUGS FOR OUTLETS ON BRANCHUNES. 3. FITTER TO VERIFY CEILINGS PRIOR TO ORDERING DROPS. REVISIONS SYM WVYUFACTURER 5.1N. TYPE MODEL SEE HANGER DETALS THIS SHEET • ®1k 4 RELIABLE RELIABLE RELIABLE RELIABLE TYCO 83615 SSP FIFR 85415 CONC PEND G4A 85415 ,CONC PEND 85714 DRY PEND TY5339 DRYHSW G4A F3QR DS -3 (ECOH) CHR BRZ 8112 CHR CHR CHR CHR BLACK CHR CHR 1/2 1/2' 1/2' 1/L 11.2 K 1/2' 1/2 1/2 155' 165° 155' 288° 155° 32 81 13 8 3 TOTAL THIS SHAT 115 Al* NCO 8® B OP BOT FO 215 FON CRYN NAS VO MOMS F1i94311 R001 BOTTOM OF BEAM 801126 OF 0E0C B OTTOM 2F x1sT 801126 CF PURA BORON OF TMS4 CUr TO 910 FED MEE RACE CF AYNL 00 AUT FACE OF WA AU10LL NO .E MESS NOTED05030DEMME 12 BOD 0 —H -- CENTERLINE OF PIPE TO REFERENCED STRUCTURE N INCHES 2 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCE) POINT N FEET AND INCHES HYDRAULIC CALCULATION NGDE FL.E CELE COUPUNG RIGID COUPLING NO. DATE BY REASON FOR REVISION CONTRACT Wf 11 J R ABBOTT CONSTRUCTION 3512 AIRPORT WAY SOUTH SEATTLE, WASHINGTON 98134-2135 PROJECT MANAGER : JED BICK FORD PHONE: (206) 467.8500 FAX: (206) 447-1885 SUPERINTENDENT : WAYNE JACKSON PHONE: (206) 854.3853 FAX: HANGER DETAIL T ( r CONCRETESTEELPANDECK FLOOR ON j 36' x 33/4' KWIK BOLT -' ^ 318' RO0 COUPLNG (2-5/8' MIN. Ewe)) 3I8'x (2-10) ATR HANGER RING HANGER DETAIL 'K HIL7T 3/8' HDI DROP N ANCHOR 310' x 3-3/4' KWIK BOLT (2-58' MIN. EMBED) 318' RDD COUPLING 318'5 (2-10) ATR (2) HANGER RINGS WITH R) TOLCO FIG. 25 SURGE RESTRAINERS TOLCO FIG. 75 SWIVEL. ATTACHMENT - 3/70 (4-0) RESTRAINT ROD HANGER DETAIL 'KR' 2ND FLOOR (Ir? BRANCHI'E DROP 1'x (ROI SCH-40, MIT WITH 90' ELBOW III 1 1' ELBOW ••::•T: (1-0 ABOVE FINISHED CELLNG) SPRNIOBI FLEX DROP DETAIL 114 (4-3) SCHF40, TXT 1 I� FOAM RUBBER INSULATION FOAM -0 -RM 1' THREADED / TEE AND PWG DRY PENDENT- " A=18' COOLER CELNG DRY PENDENT DETAIL Chi 2RCATE OF DI W ETENCY /UAW KEY Pur 5F5 co 1- z 0 Lll o 0 0 SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 96424 CONTR REG. NO. SMITHFS1380T Bus: ( 253) 926-1880 FAX: ( 253) 828-2350 JOEYS - SOUTHCENTER 633 SOUTHCENTER PKWY TUKWILA, WASHINGTON 98188 DESIGNER 1 DATE M. KELLOGG 1 02/25/08 SHEET 2 OF 2 JOB NO. T18023 �J O EY RE STAU � N ffi FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON AC© ❑ Without Comments As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire 17. c Mention Bureau for conformance with current City standards. Acce«ci--,,:>= is subject to errors and oxissions authorize violations of adopted s':zmdards and r_•i=1ir Ancss. The responsibility for the adequacy of desigr =sts totally with the designer. Additions, deletions o,_ revisions to these drawings after this date wilt void tn..3 i!cceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: ' By: 5 11 SHEET \UMBE SHEET TITLE FA -01 SYSTEM INFO IVATION FA -02 TYPICAL WHI \G A\D MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS A\D SINGLE LINE DIAGA FA -04 FLOO PLAN FRE ALAR v SYSTEM SHEET INDEX QUANTITY E 2 2 3 2 10 E E E E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING HVAC DUCT WORKS TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1G BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING 8 FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2" EXTN CEILING ®E SMOKE DETECTOR (EXISTING) HFP-11 W/ DB -11 BASE SIEMENS EXISTING CEILING HT -D E DUAL INPUT INTERFACE MODULE (EXISTING) HTRI-D SIEMENS EXISTING VERIFY IN FIELD HCP E INTELLIGENT CONTROL POINT (EXISTING) HCP SIEMENS EXISTING VERIFY IN FIELD FIRE ALARM STROBE (EXISTING) ZR -MC -CW SIEMENS EXISTING CEILING gE FIRE ALARM HORN STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING TENANT J -BOX ❑J E (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANDERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED WIRE SCHEDULE A \D CONDUIT FILL CHAT SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION maces LEVELS 250.4075f TUKWILA FIRE DEPARTMENT Pease call 205-575-4407 and give this Fire Permit No. IB -F- 1.0 it ;d exact address for shut- down hutdown or restoration approval. JOEY RESTAURANT 758 NORDSTROM E.: --j amy WFI.E15 I A .Ccf64S InDr SP.Na.R. c=:s KA., IC,: f-v`IA:.4fi JCR ,(ley PAID C �0 F>_$ 2 010 TUKWILA FIRE z 0 w w U) a w w c REV. BY: WIRE DESIGNATI I N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" - .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION maces LEVELS 250.4075f TUKWILA FIRE DEPARTMENT Pease call 205-575-4407 and give this Fire Permit No. IB -F- 1.0 it ;d exact address for shut- down hutdown or restoration approval. JOEY RESTAURANT 758 NORDSTROM E.: --j amy WFI.E15 I A .Ccf64S InDr SP.Na.R. c=:s KA., IC,: f-v`IA:.4fi JCR ,(ley PAID C �0 F>_$ 2 010 TUKWILA FIRE z 0 w w U) a w w c REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 02/13/18 2aa<aa i-oQ28 < L cc o 0 D wwC� Z LIJ v) w Q CC W w� O cc ° SCALE: NOT / 0 in= u.. Z LLI 1=1 TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/13/18 BACKROUND PLAN PROVIDED BY: C:\ \0B NUMBER:27629-1. SYMBOLS / LEGEND GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET--\ SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ — DEDICATED EMERGENCY INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ - 1 2+ 2- 2 NC C NO + - + - + - + - + FROM EXISTING MAIN FACP C CABLE C' CABLE (-) (+) (-) (+) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE NAC S4 • NAC S3 • NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) O c) STROBE SPEAKER (+) (-)C FROM PREVIOUS ADDRESSABLE DEVICE TB1 OCXXIT® NO COM NC EOLR "vvv 470 TO FAN SHUTDOWN o Q TO NEXT o p --"n. ADDRESSABLE DEVICE 0 /1/1/ HTRI-R NO ® COM B NC ® 0 Oj TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (+) \ ) STROBE SPEAKER (+) (-) cm c SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Co yri• ht 2013 by Guardian Security Systems, Inc. All Rights Reserved 141 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: SWITCH + — INPUT LED TSM -1 TO FAN SHUTDOWN o Q TO NEXT o p --"n. ADDRESSABLE DEVICE 0 /1/1/ HTRI-R NO ® COM B NC ® 0 Oj TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (+) \ ) STROBE SPEAKER (+) (-) cm c SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Co yri• ht 2013 by Guardian Security Systems, Inc. All Rights Reserved 141 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 03 M N O "Qm=i("" w 0 0 I— z >- z 0 <— Q o�z cc c o 0 < wwz cn z(,)0 w�0 z CC W<0 O co_ \ -§" 0 >- �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/13/18 BACKROUND PLAN PROVIDED BY: \0B NUMBER:27629-1) SHEET FA -02 A B C D E F G H 1 J K FIRE ALARM BOOSTER Project: JOEY RESTAURANT Panel: EXISTING BPS PAD -3 Date: February 14, 2017 Module/Device POWER BOOSTER Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) .Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 SET,MC-CW @4occi 117 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 2153 Total(A)= 15 Total(B)= 2293 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 2293 Total current ratings converted to amperes (line D x .001) 0.015 2.293 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 528 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.1910069 Add lines G and I Total Standby and Alarm AH 0.5510069 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.66120828 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 CALCULATIONS Notification Appliance Circuit Detail PROJECT::JOEY RESTAURANT Panel: EXISTING BPS PAD -3 BOOSTER POWER SUPE Wire Resistance 2.58 ate: Fe4, 2018 Date:rys...14,018 C#i.URRENT T OjpTAL= 2153.00 bq ru.•«„_l,a y'' Gil � pj . il' y 'l' Y .,. _. 1 1-i 3a ` $.!5,}:: ?:.. .. , [ .. 3 • SET -MC -CW @l5cd 69 207 SET,MC-CW @4occi 117 0 SET -MC -CW @75cd 200 0' 2 SET-Mc-CW.@95cd 264 528 2 ZR -MC -CW @15cd 64 128. ZR -MC -CW @30cd 111 0 DEVICES 7 TOTAL mA= 863 14 221 23.02 863 Total Wire Resistance (R) :(WL 2 )*(Rift) 1.14 Total Device Load, Amps (I) ._._ ..._._ ..._ (Total Cct Load) _.._---. _ _ - 0.86 Voltage Drop (E) (E=1 * R) 0.98 EOL Voltage 24 -E 23.02 i a(Ii Y'R 3•1 -' S i�. - e} '',.t , y5 wdi ` ..# SET -MC -CW @15cd 69, _ _.:. _ .... SET -MC -CW @3Ocd 111 0; 444 SET -MC -CW @75cd 200 0 1 SET -MC -CW ` @95cd 264 -69 264 2 ZR MC -CW @15cd 138 ZR -MC -CW. @30cd 111 0 DEVICES 7 TOTAL mA= 846' 14 236 22.97 846 Total Wire Resistance (R) (W L * 2) * (Rift) 1.22 Total Device Load,. Am ps (1) (Total Cct Load) 0.85 Voltage Drop (E) (E= 1 * R) 1.03 EOL Voltage 24 E) 22.97 ai.^` i�6%fie l 3s1 to i'�`r$ i -0$ SET -MC -CW @15cd 69 0; 4 SET -MC -CW @30cd 111 444 SET -MC -CW @75cd 200 0: SET -MC -CW @a 95cd 264 0 _ SET -MC -W @110cd 233 0+ ZR MC -CW @30cd 111 - 0 DEVICES 4 TOTAL MA= 444: 14 228 23.48 444 Total Wire Resistance (R) .(WL * 2 ) * (Rift) 1,18 Total Device Load Amps l (Total Cct Load)0.44 Voltage Drop (E) '(E=1*R) 0.52 EOL Voltage 24 - E) 23,48 Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0,0023 0.007 FDBZ492-HR 2 0.0635 0.0635 0.064 0.128 HTRI MODULE 5 0.009600 0.0096 0.021 • 0.105 0.0731 Amps 0.233 Amps Notification Appliance nce Circuit Detail - VOICE PROJECT: JOEY RESTAURANT Panel: EXISTING SPEAKER CIRCUIT Date: February 14, 2018 Wire Resistance 2.58 CURRENT TOTAL= 336.30 95 SET -MC @1/4 --WATT 3.54 SET -MC X112 -WATT 7,08 SET @1/4 WATT 14.14 SET @1/2 -WATT 28.29 DEVICES 95 TOTAL mA= Total Wire Resistance (R ) Total Device Load , Amps (1 Voltage Drop (E ) EOL Voltage 336.3 0 0 0 336.3 14 1263 21.81 336.3 (WL*2)*(Rift) (Total Cct Load) (E=I*R) 24-E), 6.52 0.34 2.19 21.81 (HT -R HT -D HCP EXISTING TENANT J -BOX E J EOL S S2 S,V S,V E 2S 2S cc IBPSIE S2-1 S2-2 95Cd 15Cd S2-3 S2-4 15Cd 30Cd S3-1 30Cd S3-2 30Cd S3-3 S3-4 30Cd 30Cd S1-3 95Cd 2S,62V V b EOL S3 S2-5 30Cd S2-6 30Cd S1-1 95Cd S1-2 15Cd S1-4 15Cd S1-5 15Cd SINGLE LINE DIAGRAM S1-6 15Cd S1-7 15Cd S2-7 30Cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 ISI AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 RELEASE/REVISIONS F- o ..‹.:17S «- _i/I < o z 0 D w wz W (1)wQ ›- _ `�(-§ 0 LTJ z 0 ET) 06 z 0 U 0 W co >- O� CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/13/1 8 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 27629-1 J SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved STAFF MEN'S 120 S2-3 15Cd STAFF WOMEN'S 2S 121 S2-2; 15Cdi :REEZE(R 2S —c EOL S2 S2-1 30Cd STAFF RM' 119 `••. Si -1 \95Cd i¢ S,V S,V —o D,S,2V KITCHEN W Y' 4EN'S 08 LOUNGE STORAGE 117 r c0 m 0 1 � z _O I- 0_ V C1) w 0 SHOP DRAWINGS h.�—,, DATE I � �. _ is .; ; II i n - _ 11 p a ,Y "' 7—r -ii : _ ii '.-L«- . C it Zi v I—V LINEN 1111 1 LIQUOR ST RAGE iTi7■� S1-3 95Cd S1-6 15Cd 11 a TSM i — DINING ITING PHASE 1 m PATI /0. ri ❑ ❑ FLOOR PLAN - FIRE ALARM SYSTEM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprieta and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved cc Q c ' � NO co0 O L7 z Q g LL W J I— W C/) Un 1743 IST AVE TEL. (206) 622-6545 (f) Z 0 U) W CC w U) w J W CY REV. BY: c0 m 0 z _O I- 0_ V C1) w 0 SHOP DRAWINGS DATE CO M N 0 I— oQ© o cc z Q�© D < w w z W ")WQ t�C o�c=� y- n W `_ § O ri.P�� n 0 0 LL SCALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/13/18 BACKROUND PLAN PROVIDED BY: \0B NUMBER:27629-1} SHEET FA -04 ee;e DOMING GWB CEILING (PL1N 11'-4 AFF EXISTING ACOUSTIC CUING 1Z -1 -AFF 1Z-0tu APF (0-16) ' D0SO3 StP 30 3 03 00 00 5 03 LO SOS Cxas 1 vramizatmiemismsm s, 4. le is'L79.7'a.T.111.101011111.1611611111T 4i • 6,1I2 - EXISTING GM CEILSIG (PT -IA) fa 11.-11' AFF • (0,18) -aarrm 5 —4, _ -�-- {p� sojii =s ta8 D l {{jj Al (0 '.l ppp Iilll 0 6 II - • Kim 1�X l• HSA D (Dbl — Ill wrift 11. .I , I 03-9) — 0 ® `�'• 0 4 I LA D L-10 L-10 L-10 tea -9. NEW DROPPED GWB cets4a 1V-6'AFF- .- 5 —4, _ -�-- _- sojii =s ta8 _aw =(D3lj=. tea -9. NEW DROPPED GWB cets4a 1V-6'AFF- .- ' ' • atD'aAFF ' . EXISTING 'GM minis (PT -2) • - 1 -IA 0.29) •Ilt (3-19) Ilk It riiii 1-E( ' (0.19) -\. •- . -_ 1G610 _r jD-1D)_ -�-- _- sojii =s ta8 _aw =(D3lj=. ' ' • atD'aAFF ' . EXISTING 'GM minis (PT -2) • - 1 -IA 0.29) •Ilt (3-19) Ilk It riiii 1-E( ' (0.19) -\. •- . -_ 1G610 _r jD-1D)_ -�-- _- sojii ta8 24)_0=--,-,-- =(D3lj=. ' ' • atD'aAFF ' . EXISTING 'GM minis (PT -2) • - 1 -IA 0.29) •Ilt (3-19) Ilk It riiii 1-E( ' (0.19) -\. •- . -_ 1G610 _r B.G. Woof) SLAT CEILING, TYP. 0412-3) 10'TAFF EXISTING GWB CEILING (PL -1A)' 0.0. A6ous1IC cEAING, TYF. (ACT-() 1,4" AFF . a, 109T AFF EXISTING 6118 CEILING (PT -IA) (0.19) 0 Corrugated stainless steel hose with stainless steel bral available in 2', 3',4'5 & 6' legnths . • . • • Multi -Port Bracket • • • Adjustable Hub F xHspj2 I INOUsI RIES•-'J Flexhead'"bomrtiercial Ceilirig Unit •' T-bar'Ceiling Installation ' Model #2024,2036,2048,060,2672 Design per NFPA 13 Ordinary Hazard Group 2 — 130 Square Feet Max All materials to be new, U.L. listed and F.M. approved All heads to beat least 6' apart with no obstructions • 3 - Relocate Reliable Model G5-56 Concealed Quick Response 165 Pendents % x'/2 • 3 — Plug existing • E - Existing no change Change out existing trim from silver to black (except for in the BOH acoustical grid ceiling, and restrooms) o' ;Q 4tY o Without Comments p As Noted in Rei. 't'• Per Thee ci^e2 Letter er - These plans have been reviewed bv Tile Tukwila Fire Prevention Bureau for conformance with current Cit` standards. Acceptance is subjeC'to rors and _ omissions which do not a'.i' hori2.e violations adopt =(1 standards and ordinances. The re.soo sinility for the adequacy of design itotally with the -Additions, d i izotdrawings tS �'. ce vIsior.s to t 1e7L fl S :� rav1 a -r this date Will void [s 1;3 ccceptarlCC and will require e i resubmittal of revised 6:-tiwlncs for s�so' g9�ent aopro''f• ai, Final acceptance is suo)ect to field test and inspection by The Tukwila Fire Pceventior',Sureau. Date: t> 1- 1 By: -•�: i ')I 9 �T.qa.• ,Vy, "1 j3 tom. i i c`lil� i=s I=':ta D; ir?RTh1E,'.3'�$ 1 205-575407 and Fife 1\4.0„ S -a,-1 I t4 e. 8ck- r.=ss for , r approve. 47R pi i$ PROTECTION RPRf1 J. -Abel "60 -0591 -CG: LAW 3' ;rrwn Fire pep iont;.(r`Ic._ CIh`4?WNi'G4gld: otl•,ymmtulre 001044 WWW WWW CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 - MILL CREEK, WASHINGTON ' 98082-0113 PH. (425) 481-7669 Joey Southcenter Westfield Mall - 758. Southcenter Mall Tukwila, WA 98188 ID. v 2O1) �. .-FIRE - vi 36vr�. DATE: 2,) SCALE: sojii 24)_0=--,-,-- =(D3lj=. B.G. Woof) SLAT CEILING, TYP. 0412-3) 10'TAFF EXISTING GWB CEILING (PL -1A)' 0.0. A6ous1IC cEAING, TYF. (ACT-() 1,4" AFF . a, 109T AFF EXISTING 6118 CEILING (PT -IA) (0.19) 0 Corrugated stainless steel hose with stainless steel bral available in 2', 3',4'5 & 6' legnths . • . • • Multi -Port Bracket • • • Adjustable Hub F xHspj2 I INOUsI RIES•-'J Flexhead'"bomrtiercial Ceilirig Unit •' T-bar'Ceiling Installation ' Model #2024,2036,2048,060,2672 Design per NFPA 13 Ordinary Hazard Group 2 — 130 Square Feet Max All materials to be new, U.L. listed and F.M. approved All heads to beat least 6' apart with no obstructions • 3 - Relocate Reliable Model G5-56 Concealed Quick Response 165 Pendents % x'/2 • 3 — Plug existing • E - Existing no change Change out existing trim from silver to black (except for in the BOH acoustical grid ceiling, and restrooms) o' ;Q 4tY o Without Comments p As Noted in Rei. 't'• Per Thee ci^e2 Letter er - These plans have been reviewed bv Tile Tukwila Fire Prevention Bureau for conformance with current Cit` standards. Acceptance is subjeC'to rors and _ omissions which do not a'.i' hori2.e violations adopt =(1 standards and ordinances. The re.soo sinility for the adequacy of design itotally with the -Additions, d i izotdrawings tS �'. ce vIsior.s to t 1e7L fl S :� rav1 a -r this date Will void [s 1;3 ccceptarlCC and will require e i resubmittal of revised 6:-tiwlncs for s�so' g9�ent aopro''f• ai, Final acceptance is suo)ect to field test and inspection by The Tukwila Fire Pceventior',Sureau. Date: t> 1- 1 By: -•�: i ')I 9 �T.qa.• ,Vy, "1 j3 tom. i i c`lil� i=s I=':ta D; ir?RTh1E,'.3'�$ 1 205-575407 and Fife 1\4.0„ S -a,-1 I t4 e. 8ck- r.=ss for , r approve. 47R pi i$ PROTECTION RPRf1 J. -Abel "60 -0591 -CG: LAW 3' ;rrwn Fire pep iont;.(r`Ic._ CIh`4?WNi'G4gld: otl•,ymmtulre 001044 WWW WWW CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 - MILL CREEK, WASHINGTON ' 98082-0113 PH. (425) 481-7669 Joey Southcenter Westfield Mall - 758. Southcenter Mall Tukwila, WA 98188 ID. v 2O1) �. .-FIRE - vi 36vr�. DATE: 2,) SCALE: ULC Listed Filter Detail Kleen-Gard Baffle Type Filters arc UL Classified Grease ExtractingFilters. MEA # 168-78-M Aluminum MEA # 247-96-E Stainless RESISTANCE VS. AIRFLOW - r Kleen-Gard Baffle Type Grease Filters 10 0.6 0.4 02 0275 0.175 0125 0.075 150/ 0.76 070 /1.01 250/127 700 /132 15011.76 AIRFLOW (fpm/m/s) 0025 400/203 COMPOMOTIOlt 3 CALCULATIONS UTILIZED EXHAUST CFM=LENGTH OF HOOD X CFM/UN.FT. (LOAD) SUPPLY CFM=EXHAUST CFM X PERCENTAGE REQUIRED CFM TOTAL DUCT AREA=144 X DUCT LENGTH= FPM(*) TOTAL DUCT AREA DUCT DEPTH * CAPTIVE-AIRE VENTILATOR DUCT SIZES ARE CALCULATED USING AN EXHAUST VELOCITY OF 1500-1800 FPM AND A SUPPLY VELOCITY OF 700 FPM PLEASE CONSULT FACTORY FOR MAXIMUM ALLOWABLE DUCT SIZES BUILDING CODES CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH: s s s s NFPA #96 NSF USTED B.O.CA #93-16 I.CB.O. 34416 SBCCI PST & ESI NO. 93137 E.T.L LISTED 3054804-001 LOS ANGELES RRIB080 ETL IS LISTED TO ULC STANDARDS NFPA® ETL "c" LISTING DESCRIPTION THE CAPTIVEAIRE MODEL ND HAS BEEN U.L. 710 TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 150 CFM PER LINEAR FOOT OVER 450 DEGREE COOKING EQUIPMENT ND -2 HANGING ANGLE DETAIL 1/2 DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE 1/r DIA. HEAVY DUTY NUT ONE ABOVE AND ONE BELOW HANGING ANGLE * ROD AND NUTS TO BE SUPPUED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY FOR PRICES AND QUESTIONS CAPTIVEAIRE CANADA P: 800.382.2194 E: REG20@CAPTIVEAIRE.COM F: 866.845 9754 APPROVAL TO MANUFACTURE: Approved Approved as Noted ❑ with ND Exception Taken ❑ Revise and Resubmit SIGNATURE REQUIRED BY: ENGINEER ARCHITECT DETAIL OF SUPPLY AIR VOLUME AND FIRE DAMPER ASSEMBLY 1' FLANGE FOR DUCT CONNECTION ACCESS FOR VOLUME DAMPER ADJUSTMENT SCREW (SOCKET HEAD SCREW REQUIRES 3/16 ALLEN WRENCH) TO CLOSE DAMPER: TURN SCREW CLOCKWISE. TO OPEN DAMPER, TURN SCREW COUNTERCLOCKWISE. (NOTE: DAMPER ASSEMBLIES LONGER THAN 30' HAVE TWO OBD - ADJUSTMENT MUST BE MADE AT BOTH ENDS) 7' NOM OPPOSED BLADE VOLUME DAMPER 1' FLANGE FOR CONNECTION TO HOOD 4.5' NOM 12' MA. - EXTENDS BELOW TOP OF HOOD U.L. FIRE DAMPER (INSIDE) WITH 212 DEG. FUSIBLE LINK ETL LISTING DESCRIPTION BLOCK THE CAPTIVE AIRE MODEL ND HAS BEEN U.L. 710 TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 200 CFM PER LINEAR FOOT OVER 600 DEGREE COOKING EQUIPMENT 3.00' 54.00' 12.00' 42.00' 10.00' Hood - H-5 (DISHW) 21.00' J L- 10.00' 1 10.00' 21.00' J L- A 24.00' 48.00' 8' 0.00' 24.00' PLAN VIEW - 8' 0.00" LONG 4224VHB-G DISHWASHER HOOD 12.00' PLAN VIEW - 6' 6.00" LONG 4824ND-2-PSP-F 0 1 z zw Q� >- z V U Z U I - w Zw <0 U f~-6 w J Ce 45.00' 6' 6.00' 39.00' 45.00' 28.00' 39.00' U.L. Listed Screw In Compact Fluor 0 Hood - H-4 1 r 10.00' 10.00' E 10.00' 0 ISI A 12.00' 48.00' 1 3.00' Or 11.1 v a -i MODEL 10.. + + + ... + • LENGTH MAX. C❑❑KING TEMP. EXHAUST PLENUM SUPPLY PLENUM HOOD C❑NSTRUCTI❑N EMS SYSTEM PACKAGE r 10.00 r 10.00' Q TOTAL EXH. CFM RISER(S) TOTAL SUP. CFM RISER(S) WIDTH LENG. DIA. 10.00' S.P. WIDTH LENG. 10.00' CFM S.P. 1 5424 ND -2 -PSP -F 10' 0.00' 10.00'- 1750 - � _/' 1750 -0.576' /0 /0 --I 10.00 875 YA 430 SS Where Exposed LEFT FRONT 1 16 r L11.00'1 Hood - H-3R(MAIN) U.L.Listed Screw In Compact Fluor L16.00'� Hood - H -1L (MAIN) U.L. Listed Screw In Compact Fluor 26.00' Hood - H -2M (MAIN) lit. Listed Screw In Compact Fluor. 24' 0 O L LI Q D.... •...•... 10' 0.00' 600 Deg. 2750 10' 26' 3 2750 -0.857' 1800 10' 20' .... 900 0.151' 430 SS Where Exposed MIDDLE -� ice, �- 0.00' 10.00"00' YES 11,0001 .� 1- .��/ // 20' 4 900 -% '/� 10.00' 542410' ND -2 -PSP -F % Incandescent Light 1196 10.00' - - 3.0/3.0/3.0 1196 10.00'7-/� 10.00' 1196 10' 28' 6.00' ISI % 6.00' lel ISI RIGHT 1�1 % 6.00' �% 6.00' o I ��i, //_ % 6.00' lol 4824 ND -2 -PSP -F 6' 6.00' 450 Deg. 10' ,,,j1;��i�,_�I_ 1138 -0.509' •10' 28' 1138 30.00' 24.00' 60.00' 60.00' 10' 0.00' 24.00' 60.00' J 30.00' 30.00' 20.00' 60.00' L. PLAN VIEW - 10' 0.00" LONG 5424ND-2-PSP-F 1 l V .-04.., HOOD NO. 11.1 v a -i MODEL 10.. + + + ... + • LENGTH MAX. C❑❑KING TEMP. EXHAUST PLENUM SUPPLY PLENUM HOOD C❑NSTRUCTI❑N HOOD C❑NFIG. ENDTOO ROW TOTAL EXH. CFM RISER(S) TOTAL SUP. CFM RISER(S) WIDTH LENG. DIA. CFM S.P. WIDTH LENG. DIA. CFM S.P. 1 5424 ND -2 -PSP -F 10' 0.00' 450 Deg. 1750 10' 16' 1750 -0.576' 1750 10' 24' LBS. 875 0.120' 430 SS Where Exposed LEFT FRONT 6 16 r 20 r 3 Screw In Compact Fluor 10' 24' 875 0.120' 2 5424 ND -2 -PSP -F 10' 0.00' 600 Deg. 2750 10' 26' 3 2750 -0.857' 1800 10' 20' Screw In Compact Fluor 900 0.151' 430 SS Where Exposed MIDDLE FRONT 1 Light 1 Fan 1 Other Outside YES 541 LBS. 10' 20' 4 900 0.151' 3 542410' ND -2 -PSP -F 6'10.00'450 Incandescent Light 1196 Right 11' 3.0/3.0/3.0 1196 -0.515' 1196 10' 28' 3 1196 0.148' 430 SS Where Exposed RIGHT FRONT 0 4824 ND -2 -PSP -F 6' 6.00' 450 Deg. 10' 10' 1138 -0.509' •10' 28' 1138 0.145' 430 SS Where Exposed ALONE BACK 5 4224 VHB-G 8' 0.00' 700 Deg. 1200 10' 10' 600 -0.075' 0 304 SS 1007 ALONE N/A 10' 10' 600 -0.075' 60.00' 10' 0.00' 20.00' 60.00' 30.00' 41.00' 28.00' 47.00' PLAN VIEW - 10' 0.00" LONG 5424ND-2-PSP-F n u(J.0 HOOD NO. 11vr VIL1V1131 1111V FILTER(S) LIGHT(S) UTILITY CABINET(S) FIRE SYSTEM PIPING HOOD WEIGHT TYPE QTY. HEIGHT LENGTH QTY. TYPE WIRE GUARD L❑CATI❑N FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL # QUANTITY L❑CATION 1 Stainless Steer (High E 6 16'2 r 3 Screw In Compact Fluor NO YES LBS. 2 Stainless Steel (High E 6 16 r 20 r 3 Screw In Compact Fluor NO YES LBS. 3 Stainless Steel (High E 4 16' 20' 2 Screw In Compact Fluor NO Right EMS21102 1 Light 1 Fan 1 Other Outside YES 541 LBS. 4 Stainless Steel (High E 1 16' 16' 2 Incandescent Light NO Right Ansul R102 3.0/3.0/3.0 YES 525 LBS. 3 16' 20' 5 0 NO 244 LBS. s Without Comnentt As Noted In Red Per The Attached Letter 1 nese plans have been reviewed by The Tukwila Fir Prevention Bureau for conformance with current city standards. Acceptance is ±LIblect to errors and omissions whch do not authorize violations of adopted stanGares and e;:rnances. The ref..iporisibilitv for the adequacy o1 d c,i9n r Sts to ally v/ith me designer. Additions, deie ions or r.i:vISICns to these drawings atter this dato. 1..vil, void thaw acceptance znd will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to ieid test and inspection by The Tukwila Fi4e Prevention Bureau. Date: S -1-3 By: J 41.00' 6' 10.00'Noti./6' 10.00'❑D 47.00' PLAN VIEW - 6' 10.00" LONG 5424ND-2-PSP-F TLIKWILA FIRE DEPARTM Please call: 575-440Z - and give this job No. 0 3 " 14 - 0..3., and exact address for shut' cpwn or cast :ration approval, 12.00' { 3.00' 54.00' LIGHT AND 12.00' FAN SWITCHES 1 JOB J❑EYS ❑PM LOCATION WA .DATE 12/15/07 JOB # .DWYC # J❑EYS JJRANOV BYESJ REV 4 SCALE 3/4" ULC Listed Filter Detail Klcen-Gard Baffle Type Filters are UL Classified Grease Extracting Filters. MEA # 168-78-M Aluminum MEA # 247-96-E Stainless RESISTANCE VS. AIRFLOW - 2" Kleen-Gard Baffle Type Grease Filters 1A as as 0i 0.2 1501016 100/1D1 e50/121 300/132 15011.75 AIRFLOW (fpm/m/s) 0223 0175 0125 0075 0025 CO/ 203 CALCULATIONS UTILIZED " EXHAUST CFM=LENGTH OF HOOD X CFM/LIN.FT. (LOAD) SUPPLY CFM=EXHAUST CFM X PERCENTAGE REQUIRED CFM TOTAL DUCT AREA=144 X DUCT LENGTH= FPM(*) TOTAL DUCT AREA DUCT DEPTH * CAPTIVE-AIRE VENTILATOR DUCT SIZES ARE CALCULATED USING AN EXHAUST VELOCITY OF 1500-1800 FPM AND A SUPPLY VELOCITY OF 700 FPM PLEASE CONSULT FACTORY FOR MAXIMUM ALLOWABLE DUCT SIZES BUILDING CODES CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH: • NFPA #96 * NSF LISTED • B.O.C.A. #93-16 • I.CB.O. 34416 s SBCCI PST & ESI NO. 93137 • E.T.L. LISTED 3054804-001 * LOS ANGELES RR#6080 • ETL IS LISTED TO ULC STANDARDS ETL "c" LISTING DESCRIPTION THE CAPTIVEAIRE MODEL ND HAS BEEN U.L. 710 'TES'T'ED, LIS'T'ED, AND APPROVED TO EXHAUST A MINIMUM OF 150 CFM PER LINEAR FOOT OVER 450 DEGREE COOKING EQUIPMENT ND -2 HANGING ANGLE DETAIL 1/2. DUI. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE 1/2' DIA. HEAVY DUTY NUT ONE ABOVE AND ONE BELOW HANGING ANGLE * ROD AND NUTS TO BE SUPPLIED BY INSTAWNG CONTRACTOR HANGING ANGLE IS PRE—PUNCHED AT FACTORY FOR PRICES AND QUESTIONS CAPTIVEAIRE CANADA P: 800.382.2194 E: REG20@CAPTIVEAIRE.COM F: 866.845 9754 APPROVAL TO MANUFACTURE: Approved as Noted El Approved with NO Exception Taken ❑ Revise and Resubmit ❑ SIGNATURE REQUIRED BY: ENGINEER ARCHITECT HANGING ANGLE 3' STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS EXHAUST RISER -4' 16" U.L. CLASSIFIED BAFFLE -TYPE GREASE FILTERS 100W VAPORPROOF INCANDESCENT LIGHT Q 2.75' E— ' 12'� 24' NOM SUPPLY RISER WITH VOLUME DAMPER GREASE DRAIN WITH REMOVABLE CUP 54' 33' MIN 48' MAX EQUIPMENT BY OTHERS 4 78' TYP. SECTION VIEW — MODEL 5424—ND-2 with, PSP Accessory NOTE: HOOD (S) # 1,2,3 & 4 4' EXHAUST RISER -I `FULL LENGTH ANGLE (TYPICAL) j FULL PERIMETER J GUTTER �L1 DRAIN ALUMINUM MESH FILTER 24' 42' EQUIPMENT BY OTHERS 4 SECTION VIEW — MODEL 4224—VH1 WITH FULL PERIMETER GUTTER NOTE: HOOD # 4 23.5% OPEN STAINLESS STEEL PERFORATED PANEL VERIFY CEILING HEIGHT / /i Height required to verify that the hood will fit and to size the enclosure panels INSTALLER TO FASTEN WRAPPER TO FACTORY C—CHANNEL WALL WRAPPER PANELS FLANGED FOR RIGIDITY I 1.11 WRAPPER FRONT CANOPY HOOD - WRAPPER END PRESS FIT UNTIL PANEL FACES ARE FLUSH WITH HOOD AND POP RIVET OR SCREW PANELS TO C—CHANNEL COMPLETED WRAPPER ASSEMBLY WRAPPER SCREW OR POP—RIVET POSITION BOTTOM 3/8' FLANGE OF WRAPPER UNDER C—CHANNEL FACTORY MOUNTED C—CHANNEL /TOP OF HOOD SIDE OF HOOD FIG.1 WRAPPER DETAIL SLIDE SIDE PANEL BETWEEN WALL AND 'L' BRACKET. POP RIVET OR SCREW SIDE PANEL TO WALL 'L' BRACKET. NOTCH REQUIRED WHERE SEAM_MEETS WRAPPER FIG.3 TOP HOOD SEAM DETAIL FASTEN 'L' BRACKET TO WALL WALL 'L' BRACKET INSIDE OF SIDE PANEL FIG.2 WALL ANGLE JOB WRAPPER INSTALLATION LOCATION BATE 11/27/96 JOB # DWG# HOODINST DRAWN BY JFR REV SCALE NOT TO SCALE BACKSPLASH BACKSPLASH KINK OVERLAPPED BY ADJACENT SECTION - AVAILABLE IN VARYING HEIGHTS AND LENGTHS - EASILY CLEANABLE - ONE PIECE BACKSPLASH (OVERLAP KINK OMITTED) AVAILABLE AT HEIGHTS OF 4 FT. OR LESS AND AT LENGTHS OF 16 FT. OR LESS HOOD OPTIONS HOOD NO. OPTION H -1L BACKSPLASH 80.00' High X 120.00' Long 430 SS FIELD WRAPPER 17.00' High Front, Left, H -2M BACKSPLASH 80.00' High X 120.00' Long 430 SS FIELD WRAPPER 17.00' High Front, H -3R BACKSPLASH 80.00' High X 94.00' Long 430 SS FIELD WRAPPER 17.00' High Left, H-4 BACKSPLASH 80.00' High X 90.00' Long 430 SS FIELD WRAPPER 17.00' High Front, Left, Right, H-5 FIELD WRAPPER 17.00' High Front, Left, Right, 2 JOB JDEYS DPM LOCATION WA .DATE 12/15/07 JOB # DWG # J❑EYS I2RATYN BYES) REV: 4 SCALE 3/4" HINGE KIT DETAIL FAN BASE CURB PLATE (LEFT) FAN PLATE (LEFT) GREASE BOX (OPTIONAL) GREASE PIPE (OPTIONAL) FAN IN OPEN POSITION FAN BASE ATTENTI❑NL INSTALLER SHOULD SUPPLY ENOUGH ELECTRICAL CORD TO LET FAN MAKE COMPLETE SWING. BI SERIES RESTAURANT DUTY UTILITY SET F D AU K SHAFT DIA. FEATURES: - FULL AMCA CLASS 1 OPERATION - VENTED MOTOR COVER FOR WEATHER PROTECTION - UL762 LISTED FOR RESTAURANT DUTY - UPBLAST DISCHARGE DIRECTS AIR AWAY FROM FLOOR - CONTINUOUSLY WELDED HOUSING - CLEANOUT DOOR WITH LATCHES PROVIDE EASY ACCESS WITH❑UT TOOLS - 2' GREASE DRAIN WILL NOT CLOG OPTIONS: EMERGENCY DISCONNECT SWITCH VIBRATION IS❑LAT❑RS - OPTIONAL SUPPORT RAILS FF GENERAL & RESTAURANT DUTY UTILITY SET DIMENSIONAL DATA FAN MODEL AU E D W E C F G H CC K WEIGHT LB ❑ 27 P 28 S 2 T 21 V SHAFT DIA. APPR❑X SHIPPING [LBS) HH V FF BUS 35 13/16 19 3/8 14 1/2 37 7/8 22 31 16 9/16 19 3/8 21 1/8 11 1/2 14 11/16 17 3/4 1 3/16 220 10 4 48 BI22 44 3/8 23 5/8 17 5/8 48 5/16 28 40 7/8 25 1/4 23 5/8 27 11/16 14 5/8 22 3/4 21 5/8 1 3/16 430 10 4 60 UPBLAST EXHAUST FANS (UL762) HT B } R G=R+3' RO C 4REASE DRAIN 2G FEATURES: - ROOF MOUNTED FANS - RESTAURANT MODEL - UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300°F (149°C) - GREASE CLASSIFICATION TESTING - VARIABLE SPEED CONTROL (DU MODEL) NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITH❑UT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BEC❑MING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) NCAHPFA BELT DRIVE CENTRIFUGAL UP -BLAST EXHAUST FANS DIMENSIONAL DATA FAN MODEL HT E DU5OHFA W B C Natural F R CC RO WEIGHT LB DU5OHFA 27 1/4 28 7/8 2 21 21 1/2 13 1/4 17 1/2 55 VENTED CURB 20 GAUGE STEEL C❑NSTRUCTI❑N 3' FLANGE RO RO CURB DIMENSI❑NAL DATA ROOF OPENING DIMENSIONS FAN MODEL D E DU5OHFA 19 1/2 20 GREASE BOX INSTALLATION CURB GREASE BOX GREASE BOX COVER FOR PRICES AND QUESTIONS CAPTIVEAIRE CANADA P: 800.382.2194 E: REG20@CAPTIVEAIRE.COM F: 866.845 9754 MODULAR OUTDOOR SIDE DISCHARGE INDIRECT FIRED HEATER WITH COOLING COIL, V—BANK FILTER AND INTAKE HOOD GAS FIRED MAKE — UP AIR UNIT(S) FAN UNIT NO. BTU's TEMP. RISE GAS TYPE 3 587459 80 deg F Natural —® ® DIM "X' —®– DIM 'V' –0— DIM "W" DIM "Y" - 1 ---�I DIM "M" DIM "D" DIM 20 IN HIGH EQUIPMENT CURB 1' MPT C❑NNECTI❑ FOR SS PITCHED DRAIN PAN DIM 'B" DIM 'BB DIM 'A' 0 L CURB OUTER WALL INDIRECT MODULE FLEX CONDUIT FOR FIELD WIRING V -BANK FILTER MODULE AIRFL❑W DIM "F" IJ C❑IL CONNECTIONS DIM 'CC' DIM "C' "E' POWER VENT HOOD* miiimmommlb IFTING LUGS SERVICE DISCONNECT SWITCH 0 0 0 C=== ) * o ALL DIMENSI❑NS ARE NOMINAL AND GIVEN IN INCHES. DIM "G" O O O O 0 O BLOWER/ MOTOR ACCESS DOOR FILTER ACCESS DOOR DIM 'H" DIM "J' DIM "K' DIM 'Z' DIM 'L' ROOF OPENING 2' SMALLER THAN CURB DIMENSION INTAKE HOOD MODEL u BTU RANGE (MBH) UNIT DIMENSIONS DISCHARGE OPENING TONNAGE RANGE WEIGHT A B BB C CC D E F G H J K L M V W X Y I.800-918 2546 LBS 215-3/8 52-11/16 54-3/8 54-3/8 56-3/8 49-1/165-1/4 @13000 CFM = 566 FPM 51-5/8 11-5/16 87-1/16 84 129 174 35 30 29-5/8 11-1/2 7-3/8 MODEL u BTU RANGE (MBH) GAS PRESSURE**GAS CONNECTI❑N TONNAGE RANGE MODEL CFM RANGE CFM BURNER INPUT BTU LOW BTU HIGH MIN MAX 'Z' (NPT) MIN MAX FILTER SIZE R. QTY MIN MAX MAX. FILTER VELOCITY I.800-918 800 MBH 128 640 7' WC 14" WC 1 10 Ton 25 Ton 20'x25'x2° (8) 5000 13000 @13000 CFM = 566 FPM APPROVAL TO MANUFACTURE: Approved as Noted Approved with NO Exception Revise and Resubmit SIGNATURE REQUIRED BY: ENGINEER ARCHITECT Taken ❑ 1-1YtY 11Yl 1/1 Ylrinllvl. FAN UNIT MODEL # EXHAUST FAN SUPPLY FAN FAN UNIT NO. MODEL TAG CFM S.P. RPM H.P. 0 VOLT FLA BLOWER H❑USING TAG CFM S.P. RPM H.P. 0 VOLT FLA 1 BI22CARM EF -1 BI22CARM CLOSED 4500 - 3.147' 1349 5.000 3 460 6.4 CLOSED 2 BI18CARM EF -2 BI18CARM 2334 - 2.724' 1488 2.000 3 460 3.0 3 A3 -L800-918 MUA-1 918 A3-INB.800 5884 1.250' 773 7.500 3 460 9.4 4 DU5OHFA DISH DU5OHFA 1200 - 0.750' 1336 0.500 1 115 8.1 DRAWING NUMBER EMS21102 MODEL EMS21102 1 oWH 10 11 12 13 14 15 16 17 18 19 20 21 22 0BK Frio LT, -01 .BK 1 2 PR BK PB -01 36-1--4 OR TI -01 OR K DELAYED t]IcL BK TI -01 A A2 K 7E-03 0R MS -01 RE -01 C NC BK A B NO ® RE -02 RE -01 BK Acc›B WH rtNR��4 friffe.Rfl WH RE -03 BK AccoB WH LT -02 WH WH 1 S YW 12 W-01 RE -01 42D40/0L 0D YW -2-131_=0:01,_2i . GY 13A 13B RE -01 J2D 7q 1 Y SC -01 (Sup -1) 13C LI L2 GY GYWPM TI -01 L_ .GY IN ANT BL C NC L C S NC BK BK p BK BK0 L3 BK ® BK o RD ® RDp T2 RD ti*rca RD.. TO MOTOR T3 RD ® RD o GY 3 PHASE INPUT TI RD YW 2 13A 13B 13C SC -02 (Exh-1) Duct Stats are Factory Wired W Control Is Installed In the Hood Cabinet. GY Ll BK Erma BK.: L2 BK BK L3 BK Ian BK T1 RDgx<> Rn,: T2 RD ® RDo T3RD El: nnaRD RDS YW YW 1 1 All external control wires to motor speed control should be 16-20 AVG shielded 23 nulticonductor cables and must not be run In the sane conduit or raceway with any high power wiring. Ground Shielded Cable at the drive chasis ONLY. 24 25 PG. 25 OF THE DRIVE MANUAL DESCRIBES STARTUP PRE AND EXPLAINS PARAMETER SETTINGS PG. 29 OF THE DRIVE MANUAL DESCRIBES THE PARAMETER SETTD4GS IF THE DRIVE 2 13A 13B 13C L1 L2 SC -03 (Exh-2) 3 PHASE INPUT TO MOTOR GY BK LLa BK BK L3 T1 RCM BK BK o BK T2 T3 RD prai RD RD® RD RD ltArMI RD 3 PHASE INPUT TO MOTOR 181n. x 201n. x 8.61n. Box jnstalled Options Hood Light Switch Exhaust On In Flre Label, LT -01 LT -02 LT -03 MS -01 PB -01 RE -01 RE -02 RE -03 SC -01 SC -02 SC -03 Identlflca ion Location 'POWER ON' Light C1] 'FANS ON' Light (47 '100% OVERRIDE Light C2] Fire System Micro -Switch (5] Push Button Override (3] DPDT Relay (53(63(8) Auxiliary DPDT Relay [5] Timer/Push Button Relay I4] Su -1 Speed Control (6-10) Exh-1 Speed Control Exh-2 peed Control I11-157 (16-20] SW -01 (37(63 SW -02(21 TI -01 100% (3X67 TS -01 Duct Stat (Open on RIseX63 TS -02 Duct Stat (Open on RiseX6] Fan On/Off Switch Hood Light Switch O Override TI a mer CIENERAL DRIVE PARAMETER SETTINGS 03 - AUTO RESTART VITH DC BRAKING (04) 05 - PRESET H1 (02) 10 - PRESET SPEED f1 (04) U - PRESET SPEED *2 (04) 12 - PRESET SPEED *3 (04) 19-100 SEC. 20 - 300 SEG 23 - 60 Hz 24 - 60 Hz S?FiC(FICIDRIVE PAIr�TUETTINGS Paranettwer*-31 = 60 Hz Parameter=31 = 60 Hz Paraneter*32 = 54 Hz Paranetert33 = 48 Hz Paramater*33 = 54 Hz SC -03 (Exh- Parameterit36 = 48 Hz Paronetere31 = 60 Hz Paroneter#33 = 48 Hz SPEED * TB -13A TB -13B TB -13C 1 OPEN OPEN 01,D4 1 [LASED OPEN OPEN 2 OPEN CLOSED OPEN 3 OPEN OPEN CLOSED 4 CLOSED CLOSED OPEN 5 CLOSED OPEN CLOSED 6 OPEN CLOSED CLOSED 7 CLOSED CLOSED CLOSED SPARE RELAY CONTACTS Spare relay contacts can be used to control Items requiring shut down when the fire systen sdischarge; such as shunt tris. 1 NC 3 NO 7 CUM 9 A COIL RE -02-1 MS -02 NC _ . NC • C -RD NO -BK NC -BR Terntal for field wiring to bidding fire contacts fdry or Mgral only. NOTES DENOTES FIELD WIRING DENOTES INTERNAL WIRING Drawing shown De-enerptzed TB -12 must be Junpered to TB -2 for FIRVARD PG. 42 of the drive manual desclbes how to set up the preset speeds. Drive defaults to preset speed *1 when no contacts are made. WIRE COLOR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY OR - ORANGE OR/BL - ORANGE/BLUE RD - RED (STRIPE) WH - WHITE BL/RD - BLUE/RED PR - PURPLE (STRIPE) PK - PINK RD/GN - RED/GREEN (STRIPE) JOB J❑EYS DPM LOCATION WA .1).44 YE 12/15/07 TOB # .12 ITC # JDEYS DRAWN BYESJ REV 4 SCALE 3/4" PLENUM PR❑TECTI❑N NOZZLE DUCT PROTECTION NOZZLE TYPICAL ANSUL R-102 SYSTEM LAYOUT REMOTE MANUAL PULL STATI❑N REMOVABLE STAINLESS STEEL SERVICE DOOR AGENT TANK DEM RELEASE/ BRACKET ASSEMBLY LEGEND FIRE CABINET ANSUL SYSTEM 1A 1.5 GALLON TANK 1B 3 GALLON TANK 2 OEM AUT❑MAN RELEASE 3 OEM REGULATED RELEASE 4 OEM REGULATED ACTUATOR 5 ANSULEX LIQUID AGENT (3 GAL.) 6 ANSULEX LIQUID AGENT (1.5 GAL.) 7 CARTRIDGE (101-20) 8 CARTRIDGE (101-10) 9 CARTRIDGE (101-30) 9A CARTRIDGE (LT -A-101-30) 9B DOUBLE TANK CARTRIDGE 10 TEST LINK 11 DOUBLE MICR❑SWITCH 12 HOSE ASSEMBLY 1100 DUCT NOZZLE (430913) 2W DUCT NOZZLE (419337) 1W NOZZLE ASSEMBLY (419336) 1F NOZZLE ASSEMBLY (419333) 1N NOZZLE ASSEMBLY (419335) 1/2N NOZZLE ASSEMBLY (419334) 3N NOZZLE ASSEMBLY (419338) 245 NOZZLE ASSEMBLY (419340) 230 NOZZLE ASSEMBLY (419339) 2120 NOZZLE ASSEMBLY (419343) 290 NOZZLE ASSEMBLY (419342) 260 NOZZLE ASSEMBLY (419341) 28 DETECTOR BRACKET 29 LOW TEMP FUSIBLE LINK 30 HIGH TEMP FUSIBLE LINK MGV MECHANICAL GAS VALVE EGV ELECTRICAL GAS VALVE 34 REM❑TEiMANUAL PULL STATION S SWIVEL ADAPTOR ANSUL PULL STATION DETAIL PULL SCREW HOLES AT 2 D'CLDCK AND 8 O'CLOCK 1/2' CONDUIT STRAIGHT UP TO ABOVE CEILING LINE, NO OFFSETS DR BEND 4' STANDARD ELECTRICAL OCTAGON BOX 5' ABOVE FINISHED FLOOR DR IN ACCORDANCE VITH LOCAL CODE. A.F.F. NOTE HEIGHT OF PULL STATION SHOULD BE DETERMINED IN ACCORDANCE VITH AUTHORITY HAVING JURISDICTION. FACTORY PIPING - - - - FIELD PIPING ANSUL R-102 FIRE SYSTEM SPECIFICATIONS W In J W ▪ LJ Z J 0 Z¢ LJ = 1 � W 1-10 W Y X CC 1- O LJ MI IW J Z J Z ¢ J CZI- V)I- >- to A LZi A BZW (n LI Hi ¢rx O re• Ni NO¢ ZJ L -L A V) W W I- L- 1 1- Z LL. ¢D3 I -I -A �w 3� W LAJ Q>I- I-H3 1-- Z W X In UJ ce Z 4-4 �V)z .CE z Z ¢U Z LLI F- o ZYCL¢ �0Z� w W -I¢ C] fl ¢ Z 0_LL-wi ¢LIT A I_ W Z J W J W V) A ¢ 2ZL-+O V)O 0 1-IWJ Z¢LI �.Q, Q X W C:1LL- CZ CZA(4 W < O H I- OV)CCO Z W 1- I-W¢Z X I- W `--L W < OLJ LJ H x¢03 W l71 M LJ D A J U ¢¢W� W>ce 4-4 1 3JW 1- W Lj F4 - N A ww¢ ¢WCe O= W La WV)0_1- i Ce 0 - J I- Q.. - J l7 0 z Li Xc¢Li Li CL ¢IOJ w id WF- 1- Z_ (W/)WOJ J 0 z J Ld AP�iy (n WoLL_X U W 1- ¢w v) - LJA¢ H LddLD a_Ji2fO R ¢ ¢ 2rZLLZ�Zi (nJ BUILDING CODES CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH: * NFPA #98 * NSF LISTED • B.O.C.A. #93-16 ✓ 1.C8.0. 34416 • SBCCI PST & ESI NO. 93137 • E.T.L LISTED 3054804-001 • LOS ANGELES RR#8080 ✓ ETL IS LISTED TO ULC STANDARDS CjD NFPA® UL(C) LISTING DESCRIPTION THE CAPTIVEAIRE ANSUL SYSTEM HAS BEEN U.L. 300 TESTED, LISTED, AND APPROVED TO BE PRE -PIPED IN THE FACTORY. FOR PRICES AND QUESTIONS CAPTIVEAIRE CANADA P: 800.382.2194 E: REG20@CAPTIVEAIRE.COM F: 866.845 9754 APPROVAL TO MANUFACTURE: Approved as Noted ❑ Approved with NO Exception Taken Revise and Resubmit ❑ SIGNATURE REQUIRED BY: ENGINEER ARCHITECT r L NOTES - FIELD PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE. - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE, - IF APPLICABLE, PRE -PIPED CHARBR❑ILER DROPS ARE SHIPPED LOOSE. FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE - APPLIANCE DIMENSI❑NS LISTED REPRESENT THE C❑❑KING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS HOOD, NOTE. CAPTIVE' AIRF SYSTEMS ASSUMES RESPONSIBILITY FOR THE PRE PIPING OF THE FIRE SYSTEM BASED UPON THE COOKING EQUIPMENT INFORMATION WE RECEIVE: IT IS THE CUSTOMER'S RESPONSIBILITY TO VERIFY THE COOKING EQUIPMENT LOCATION, SPACING, AND COOKING SURFACE DIMENSIONS. THE CUSTOMER IS RESPONSIBLE FOR ADDITIONAL CHARGES AS A RESULT OF COOKING EQUIPMENT LAYOUT CHANCES AFTER THE RELEASE OF AN ORDER, UNION LABOR CHARGES, OR ADDITIONAL TRIPS MADE BY THE FIRE SYSTEM DISTRIBUTOR CAUSED BY JOB SITE DELAYS. 8z -1 4 T P NT L_ 15' -----T------1 1 1 1 1 L ___ ___ 0 1 0 1 1 1 ___ ___ J- ___ ___ 1 1 1 1 1 ___ ___ JL r ___ 1111111 11' ___ ___ 0 r --- '1 r 0_JL___ Q ___ ___ ___ Q ___ _ --JL----JL 0Gs- 6ula.oJ Aq.lwlxo,.Ad ON Aq_!1 xo.ad '-161H r I 0 1 11. a r00'2Ex 1 ,00'2E Jawnaq_S a r00'2Cx 1 ,00'26 uan❑ I---- ► 1 1 1 ----JL- '10.17' 8z -1 4 T P NT L_ L EXTRA QS,- EXTRA QS 15' -----T------1 1 1 1 1 L ___ ___ 0 1 0 1 1 1 ___ ___ J- ___ ___ 1 1 1 1 1 ___ ___ JL r ___ Q ___ ___ ___ Q ___ I 11' ___ ___ -I Q ___ JL I-13.00' r --- '1 r 0_JL___ Q ___ ___ ___ Q ___ _ --JL----JL 0Gs- '1 10 15' Ir ----- I 11 11 11 0 1 1 1 1 1 r I 0 1 11. 7 0 JL 1 1 r -1 H 11 11 d 1 11 11 JL I---- ► 1 1 1 ----JL- '10.17' 15r 1 1 1 1 r- -1 11,,,r 1 1 1 J • 1 -14.00' ___!--16.00" 15.00' ___1 12,001J-12,00' 13.00' 12.00"--L-10.00" HOOD # 1 14.00' 24.00' 30.00' 15.00' HOOD # 2 12' 12' - HOOD # 3 L EXTRA QS,- EXTRA QS 6 INCHES BELOW HOOD System EXTRA QU CK SEALS TO BE PLUGGED IN FACTORY Size: ANSUL-3.0/3.0/3.0 Total FP required: 29 Long x 54" Wide x 24" High x 16" Long x 54" Wide x 24" High x 26" Long x 54" Wide x 24" High x 11" Long x 48" Wide x 24" High x 10" Fryer -M w/Drip Board 16,00' L x16,00' D High Proximity Fryer -M w/Drip Board 16,00' L x16,00' D High Proximity J fI fo Range -Shelf .. 12,00' L x24.00' D High Proximity - -_ 1 r Oven 38.00' L x24.00' D High Proximity hooa IT Riser # Hood # Riser # 1 1 2 1 r- 1 f !/ Hood # 3 6' 10.00" Riser # 1 Size: 10" r Hood # 4 LJ /----\® # 1 Size: 10" a 1-------1e--L_ ® 12.00'j-12.00' 28 Q11 @ : ------J-(5.I 15.00' -- 28 EXTENDS J p ----1 ei 1N _I r 13.00'. 1 12.00'----10.00' L1® "'' L_ @ -_I__ 30.00' 28 .I 1 -"' 28 --1----- @ ---14.00' 16.00' • 15.00' 13.00' -14.00" 24.00' v NOZZLE 6 INCHES BELOW HOOD System EXTRA QU CK SEALS TO BE PLUGGED IN FACTORY Size: ANSUL-3.0/3.0/3.0 Total FP required: 29 Long x 54" Wide x 24" High x 16" Long x 54" Wide x 24" High x 26" Long x 54" Wide x 24" High x 11" Long x 48" Wide x 24" High x 10" JOB J❑EYS DPM `� 2 Sc C V V L LOCATION WA DATE 12/15/07 JOB # .D TVG # JOEYS .DRAIN. BYESJ REV. 4 SCALE 3/4" Alr) 20 20086) Tukwila Fire -F-00Jotivue1 Fryer -M w/Drip Board 16,00' L x16,00' D High Proximity Fryer -M w/Drip Board 16,00' L x16,00' D High Proximity nge-Shelf (20"Min from gra- 36.00' L x24.00' D High Proximity fo Range -Shelf .. 12,00' L x24.00' D High Proximity (o (o WV) S =off (Oo') S -oro X ON - 3 0 ;71: O-5 O C13 (0 A ci- et) Fryer-M w/Drip Board 16.00' L x16.00' D High Proximity Gas Radiant Charbroiler - S 60.00' L x24.00' D High Proximity NGl 4-5 (0 o Q aQ (0 � r O x O N x - 3_p� Kettle 16.00' L x16.00' D No Proximity Rating Oven 38.00' L x24.00' D High Proximity hooa IT Riser # Hood # Riser # 1 1 2 1 I.U. ULUU Size: 10" 10' 0,00 " Size: 10" Hood # 3 6' 10.00" Riser # 1 Size: 10" Hood # 4 6' 6.00" Riser # 1 Size: 10" JOB J❑EYS DPM `� 2 Sc C V V L LOCATION WA DATE 12/15/07 JOB # .D TVG # JOEYS .DRAIN. BYESJ REV. 4 SCALE 3/4" Alr) 20 20086) Tukwila Fire -F-00Jotivue1 SHEET INDEX FIRE ALARM SYSTEM TUKWILA, WASHINGTON GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL_ DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYTEM FA -03B FIRE ALARM SYTEM ROOF FA -04 SITE PLAN, SYSTEM CALCULATIONS (GENERAL), RISER DIAGRAM. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCT❑RS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO 4416 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR 4414 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR 1414 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED 1118 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWD #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END Without Comments As. Nc Iri Red Per Attached Lotter ese pleas hew', `... ;r r.;.• i. P-evention E r . -.. .c slandardc. O nissians s .anaaro adequacy Pddition5. this date. ,_, I - r submittal of r: ..:; by Tilc; f u1.,. ,it. , ;�Ir cur;cntcit\' and !7.1z2JiY atter G�rea approval. Final accer*inc .suclecT to t:eid tes ana u The Tukwila Prevention Bureau. Date: By: fUKWILA FIRE DEPARTMEN Please call: 575-4402 and give thls job :nd exact address for shut . aovrn or restoration approVa! ' NOTICE A completed, signed, T ukwllei Fire Department Pre-test Certificate must be presented to the Inspector.prior_.to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing, 1,,14/1 //Od a7r cLev<<-e Or+ cie,A;c FA,) -71. qrw b►tsiker. --Sy14c1.,1a cov-rty w'rh' AnyA 7). ?.007 -e oI; FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE,; FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT; AIR STREAM OF AIR SUPPLY OUTLETS. PER NEPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE E SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED: BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHE'!ER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 9. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14: ALL 12OVAC CIRCUITS ARE FROM DEDICATED :CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS 'HALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. - DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS: BETWEEN CONDUCTORS, AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED, ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM " THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. t: 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NEPA 72 2002 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2002 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING- AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE I5 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22` M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 4 1 1 12 3 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY. SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT HTRI-D SIEMENS INTERFACE MODULE 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE - HCP SIEMENS 4S DEEP VERIFY IN FIELD 1 HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD 11.�,,� LINEAR BEAM 31<1 SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1 G RING CEILING DUCT SMOKE ®D DETECTOR AD2-P W/ SIEMENS TSM MODULE. DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING gL C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS. 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM n STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. 9c FIRE .ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. Q FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM FIRE ALARM I B STROBE WP (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2". PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JBOX FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.❑. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAID ` , i - 2008 Tukwila Fire o. ri • ht 2006 b Guardian Securit S stems, Inc. All Ri• his Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS- ,z DESCRIPTION -o it z 'w ;0= ce rcs 0 In w 0 0 co 0 z C C w Qp CJS w z W oC w co O < W se CC OD aCk `SCALE::1 DRAWN BY: '. (.ANDERSON, DESIGNED:: BY: R.VEZZANI DATE: 4/03/0 BACKROUND,PLAN PROVIDED BY: <\OB NUMBER: ;/- SHEET 1 1 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE VATH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' ME, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS DUCT DETECTOR LOCATION o TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT 0 LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL SE END OF LINE DEVICEC3.6K 1/4W) SUPERVISED SWITCH 0 GROUND -0 re) LC) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O 0 O O HTRI-R OSTATUS LED 00 h 0 0 0 N.O. COM N.C. Am TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL SEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE L - + NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING --Th TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE {(-) FROM XLS CONTROL PANEL OR �`¢) PREVI❑US ADDRESSABLE DEVICE (-1 END OF LINE ? 1 DEVICE �T (3.6K 1/4W) SUPERVISED i RELAY CONTACTS SWITCH C4.0A @ 125VAC) GROUND C4.DA @ 30VDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED;. AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE ; 0 0 r) LC) O 0 HTRI-D STATUS LED 0 0 /NOT USED / O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LEL SC4E(FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC lel 0 0 0 110 0 El 0 PAD=3 0 O 0 INPUT .: -INPUT - TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1- 1 2+2-.2.NC C NO + - AMIMI MIAIAKIAK 24K FRONT VIEW NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE _ tea,,, DEVICE LOOP NOT USED REMOTE DEVICE LOOP!. 0- 0 FROM; XIS COMM. PANEL OR (-0> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS iW EOL T M-1 O • TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL i EARTH GROUND 0 -34-E)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE FROM REMOTE POWER SUPPLY C'S' CABLE) END OF LINE DEVICE FROM.. FACP 3.6K 114W) = CVOICE CIRCUIT) ('V' CABLE) UPERVISED 1 SWITCH SCALE NONE (-a) (-) STROBE SPEAKERr () STROBE ( ) STROBE SPEAKER (+) (-) a SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STRO3E ONLY 11111 Q O NAC -4 2 NAC -3 NAC -2 ?NAC -1 4S DEEP BOX W/ 1 -1/2 - EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERMIN TEMPERA +327 (0' C TO 10O' F C HUMIDITY; O- X RELATIVE HUNT TY.. NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE f DATA IN (-) > - t DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCOTY APPLICATIONS OF 300-4000 FTAIN MEN USED IN CONJUNCTION *111 DUCT HOUSINGS AD -11P OR AD-11XPR D8--11 /� STANDARD SMOKE DETECTOR BASE TO NEXT DEVICE F REAR VIEW > ( ) DATA OUT > (1-) DATA OUT HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SUE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID —\ HARD LID CEILING SPEAKER SUPPORT TILE" ------ BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION `\. -----CEILING MOUNTED ----N SPEAKER/STROBE W cc D REV; BY: Z:` a:Q ---- ---- ... .----.. w. DESCRIPTION---- ------ ------ . PRELIMINARY SHOP_ DRAWINGS..... OD 3/18/08-=- z C«<C CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTI❑N BOX MOUNTED ON . \ CEILING FLEX \ / / / / f / / / JUNCTION BOX --=-\ MOUNTED AGAINST CEILING SUPPORT 0 0 ; I TO NEXT DEVICE 0 0 -CADDY BAR SMOKE DETECTOR ----- SUSPENDED ILLUMINATED CEILING ALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SLATE=NONE SMOKE DETECTOR MOUNTING SCALE:NONE SCALE:; DRAWN BY: (.ANDERSON DESIGNED . BY: R.VEZZANI DATE: 4/03/08 BACKROUND:PLAN PROVIDED BY: JOB NUMBER: Copyright -'2006 by Guardian Security Systems, Inc. All Rights Reserved 4 1 - — - 2s,2V �i a > N H N $P 0 HCP i1\\ ill A 2S,2V N EOL S2 19.35 75 • >• -0 S,2 V,D 1-1 N COL Si 18.50V II 30 2S,2V id 75 S,2 V 110 2V,S 2S,2V 0 11 110 Ti s,(�v , 5 STROBE CIRCUIT CABLE UP TO SECOND FLOOR VOICE CIRCUIT CABs .F UP TO SECOND FLOOR DATA LOOP UP TO SECOND FLOOR DEVICIES UP FROM FIRST, FLOOR BOOSTER POWER SUPPLY DOWN TO TENANT FIRE ALARM JUNCTION BOX RE REV. BY: Z QQ. 'Z -DESCRIPTION PRELIM-INARY SHOP DRAWINGS SHOP . DRAWINGS- FOR SUBMITALS til l -- d n 3/14/08 60 a co M 9 ««< Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved �CALE:' 1 DRAWN BY:'.. LANDERSON DESIGNED . BY: R.VEZZANF. BATE: 4/03/08 BACKROUND PLAN PROVIDED BY: OB NUMBER: SHEET -0 l; STROBE CIRCUIT CABLE UP TO SECOND FLOOR VOICE CIRCUIT CABLE UP TO SECOND FLOOR DATA LOOP UP TO SECOND FLOOR DEVICIES UP FROM FIRST FLOOR BOOSTER POWER SUPPLY DOWN TO TENANT FIRE ALARM JUNCTION BOX DRAWN. BY: 1.ANDERSON DESIGNED BY: R.VEZZANI DATE: 4/03/08 BACKROUND PLAN PROVIDED BY: OB NUMBER: SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved