Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 800 SOUTHCENTER MALL - APPLE COMPUTER INC - PERMITS AND PLANS
800 SOUTHCENTER MALL ASSOCIATED PERMITS 14-F-089 09-F-021 14-S-080 14-S-077 08-S-540 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address'623"Sr"outcenter Mall #228 Suite Number: Floor: Tenant Name: Box Lunch #4530 New Tenant? ❑ - Yes 0 - No Property Owner's Name: Westfield Shopping Center Mailing Address: 633 Southcenter Mall #228, Tukwila, WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Mailing Address: 1743 First Ave S, Seattle, WA 98134 kveliz@guardiansecurity.com city State Zip E-mail Address: Fax Number: 206.374 2952 Contractor's City of Tukwila NICET II1 number: Business License number: GUARDss233K6 Exp. 09/30/2016 Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 3600 Scope of Work (please provide detailed information): Fire Alarm System Alteration: Add 1 device. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING SbWNER OR A1l/THORIZED AGENT: Signature: Date: -—(w 1 Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 800 Southcenter Mall King Co. Assessor's Tax No.: 9202470010 Suite Number: 800 Floor: New Tenant? El - Yes ❑ - No Tenant Name: Quilts ETC Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave. South, Seattle, WA 98134 kveiiz@guardiansecurity.com city E-mail Address: Fax Number: 206.628.4990 State Zip Valuation of Project (contractor's bid price): $ ' Scope of Work (please provide detailed information): Adding 12 devices to existing FRCP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING y NER-OR AUTH i ' ED AGENT: j Signature: . 4 Date: I f 21 - ` Print Name: Karina Vel Z Day Telephone: 206.349.5889 Plan Permit App.doc 5/14/10 TFD FP Form 8 44"444 IMRE SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: '1 z d ,--17-0010 Site Address: 0 (o $ SO J -1-kL211-ke ( / 5,0 GSL e g 0Suuite Number: $00 Floor:1 Tenant Name: lX 0 , 1 A'S EJ(.— — New Tenant? VI- Yes ❑ - No Property Owner's Name: J.A1 Q5-kCiel (o(7ofii4Io(\ c� Mailing Address: Z ODgSeg i(Via�fvv r �'t o �, (U �,( 1,1 i 1 A (J %� .8 1 City State Zip CONTACT PERSON -if there are questions about the submittal. 6a/ 1 Name: Ci `t5k l e OA ar\ Day Telephone: l.4 ZS— 361—t 105 Company Name: C CO) (\ C. l i- P r D G k- ion, 111 c Mailing Address: Po 60i 2- t i y(i i/ 1 if -eek t fig 980e2._ Z E-mail Address: Cr i S k ; e e c co w n f p* (0 rn City IFax Number: "1 as-- UState 1- goip 9 5 - Total number of new/relocated devices or sprinkler heads: 2 2. C I b G 12 (e 1 o ca -C) Valuation of Project (contractor's bid price): $ 5 0 0 0 I I d � I- ^ Scope of Work (please provide detailed information): A d 10 e a cis andff re 1 OL 44e /a inLtI or reads r knar#!5 OLL Du - PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: (7l', S h 0/il col d Plan Permit App.doc Date: // 6 /I Y Day Telephone: 421-L4'1-766 9. 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Quilts 800 Southcenter Mall Permit No.: 14-S-080 Date: April 22, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Mariners Team Store 800 Southcenter Mall Permit No.: 08-S-540 Date: December 30, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more heads require hydrostatic test and system isolation if necessary. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2007 Edition. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C —CLAMP WITH SET SCREW 3/8' ALL THREAD RDD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER. DETAIL NTS . FlexHeap Sprinkler Drop Corrugated stainless steel hose with stainless steel bral Tarall,kle in 2, 3',4',5' & 6Iegnths . • • . • ' • -•. • • Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart 1) REFLECTED. CFILINO:-PLAN . .1/47 :=. Multi -Port Bracket • • Adjustable Hub • , • :• FLEXIliA/3 nrerriTTETPCy. — • , ' • F.lexhead omi-rie.rcial T -Bar Ceiling Installation ' Model #2024 2036 2048 (:)60 2672 ' . c o Without Comments O As Noted -In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire lrevention Bureau for conformance with current City :tandards. Acceptance Is subject to errors and 2inissions which do not authorize violations of adopted andordirrances. The responsibility for the ,lciequacy of design reststotally with the designer. deletions or revisions to these drawings after Ifals date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. 5inal acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 1'1 By: Vie mmmm 'as mmmmmm is mmm :wilt s .le m eim.e.pminim.fts. - ill WASHINGTON STATE 1 - FIREPrOTIVAACZWICAICERESPWTENIS John J. Abel - • - - -- . ' - .- . 9760 -0591 -CG - Level 3 •- - Crown Fire Protection,.Inc. - i CR WNFP044 • ia sLIJAA11 re ff• na O tO — Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 xY2 (white) o Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 (white) CROWN FIRE PROTECTION • INCORPORATED P.O. BOK 12113 MILL CREEK, WASHINGTON 98082-0113 • PH. (425) 481-7669 m • TUKWILA FIRE DEPARTt4ENT Please call 206-575-4407 and give this Fire Permit No. /Li -S- 0 5? 0 and exact address for shut- down or restotaton approval. MALL KEY PLAN .4$,_ Vfi Nita1,441,1Kilt Li Quilts 1068 Southcenter Mall Space 800 Tukwila, WA 98188 DATE: Li DRAWN: SCALE: (/ APR 1 TUKWIL I C ID 7 2014 FIRE 'Ss FAX TRANSMITTAL 04/16/2014 11:26 4254818695 CROWN FIRE PAGE 01/01 Fax No. CROWN OWN FIE PROTECTION, INC. Ih t 4.16.14 Fire Prevention Bureau Tukwila Fire Department / ,A,1 Demo Permit Num (Including Co 1 ❑ Urgent P1 For Review 0 Please Comment 0 Please Reply 206.5754439 Cristie Ogland Prl;425.4g1.7669 • FX:425.481,8695 omments Please provide a demo pezmit to remove (5) sprinkler heads that are in the way of the framing at the Quilts's project at 1068 Southcenter Mall, Space #800. The building permit # is D13-0384. Please let us know if you have any questions. •thanks-•- TUKWILA FIRE DEPARTMENT Please call n6-575-4407 and give this Fire Permit No. l9 -S -o and exact address for shut- down or restonon approval. GtERTIj IICATE OFO sIrw NCY FIRE PROTECTION SPRINKLER SYSTEMS • John J. Abel 9760 -o591 -CG Level 3 Cro Fire Protection, Inc. Is• CR: NFP044LL P.Q. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8695 • IL � FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON Without Comments o As noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire "revention Bureau for conformance with current City standards. Acceptance is subject to errors and .missions which do not authorize violations of adopted andards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: Ll- ^ I ( 8y: % J I SHEET NUIV 3ER SHEET TITLE FA -01 SYSTEM I N FO MATT O N FA -02 TYPICAL WIRI\G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATION S AND SINGLE LINE DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX WIRE SCHEDULE AND CO\DUIT FILL CHA RT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPUFPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPUFPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPUFPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPUFPLR RED (JACKET) V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLJFPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPUFPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANG=RS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE VYITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 2 2 2 1 3 2 SYMBOL DESCRIPTION MODEL NOTICE Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the te- tinq TUKWILA FIRE DEPARTMENT` Please call 206-575-4407 and give this Fire Permit No. I �l-F-off and exact address shut- down hutdown crr res mon approval. MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP AIR DUCT HOUSING W/ SMOKE DETECTOR FDBZ492-HR W/ SIEMENS DUCT HOUSING HFP-11 DETECTOR HVAC DUCT WORKS HT -M SINGLE INPUT INTERFACE MODULE HTRI-M SIEMENS 4S BOX VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM QQ HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S BOX CEILING FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX CEILING CI JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND QUILTS ETC 800 t'yy� LI TI'E FLI CS::.42 I I si ��wF+`3:�`rti s PNC FIX �Tn4:aAs4 o t i GATE CDTs ERSTING JCPenney .LEVELS WIRE DESIGNATION GENERAL NOTES SITE PLAN FA -01 Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved J 1 PAID Q. c_ 201i PR i i .fUKVVlLA FRE l'6- 20' FAX (206) 628-499 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 03 0 2<<aaa Z co o 1- Qrn 0 ca < WO W w ZZ 65Oc CC 0 c4 U) - cc cow LL �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/18/14 BACKROUND PLAN PROVIDED BY: '0B NUMBER: 8656-1} SHEET THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 12OVAC-60HZ DEDICA1TD E,IERCENCY -( HOTS FOR ADDITIONAL SPE( CAPONS SEE PRODUCT OOCUIENTATION. *CONTACT RATINGS: 4.OA 0 125VAC 4.OA 0 30VDC TO DEVICE ADDRESSABLE TCPNEXT LAST FR[II XLS MITRE. PANEL( IR PREVIQIS ADDRESSABLE DEVICE - 0 FROM PREVIOUS ADDRESSABLE 2 DEVICE HFP-11 TB1 ®® NO COM NC 2 TO FAN SHUTDOWN EOLR ./wv, 470 SWITCH + - INPUT LED TSM -1 HTRI-M RED BLK + TO NEXT 00 ADDRESSABLE DEVICE ORG ORG GRN NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PFODUCT DOCUMENTATION. TYPICAL DUCT DETECTOR/HTRI-M MODULE/TSM-1 SWITCH WIRING DETAIL INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - 3.6k EOL C -CABLE 2 SPARE SPARE SPARE C -CABLE (-) HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY + u HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TING TEMPERA RE: +32' F (0' C) TO 100'F (38 C) HUMIDITY: 93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR — FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FTA1IN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL HARD LID CEILING �00�0► 00 SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING 7- HORN STROBE STROBE ONLY DROP CEILING MOUNTING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX �i..frrSAage4AtakAAmLAXER4MOSM. 4 C MOUNTED AGAINST CEILING SUPPORT 1 0 O TO NEXT DEVICE ---CADDY BAR SMOKE/HEAT DETECTOR \\- SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved m 0 4,2 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 1 DMG I DESCRIPTION SHOP DRAWINGS a o .d- 00 0 2 CCCCC Z o O Q U 8 �z w W wzz I- 65 6 O(i) CC od Q ci)— W 0 CC c0 LL F - z O O Z c� z SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/ 18/ 14 BACKROUND PLAN PROVIDED BY: .0B NUMBER: 8656-21 1' SHEET '' FA -02 ' < t�AF{?,•d Z''*, M'+'�`f� d� i ! V ' +� t . a'� i, � {' Fii m' " p '.:,u' 1 ya ? , Z 43t Y ,fl t ✓4 tr Y4Y ,''. . ,k '�},,t:fM1:� t"',','• r b � y� R, 4 a ry .6 'S f d h'd �, S: 1 l r! r J r y 1 {, ,, h 5'r', d, "� .}Ai,.r !?ad � v}'„ ,,,r4„:i.�a„n,.',,4 4t .: 4�,�zV„ „ •' ,'5tr, ,,., , . •A',M^ ' .. ? P�,r 9m„+ tii„�'�r � ,hpf$ Vt.�t;. �T:. a, 6 ,.., � .1., � zSt, i t R WiT, 1,, .:� � a ,... t DATE co Curry { :;.V dr ii t? Current Load: S fldi / Standby: Alarm: Device Type Device Type Qty Qty Amps Total Total Amps Total HFP-11 Detector 2 0.0015 ^ 0:0030 0.0015 0.0030 Main System Board FDBZ492 Duct Housing 1 2 0.0001 0.03 0.0002 0.0500 0.1000 71 -MC -CW a15cd HTR R Module . 12 1 0:0010 0.0010 0.0010 0.0010 ZH-MC-CW @30cd HTRI-M Module 9 2 0.0015 0.0030 0.0015 0.003 ZH-MC-CW c 75cd 8 ; 0.222 0.2 1.600 ZH-MC-CW @95cd 2 0.292 0.0072 Amps 0.1070 Amps ZR -MC -CW cd .. ,. ,,, rGr, z., >,, .", ., .7JwF . ,. 'h• ,., ,5,,w ,,.:, �' �,i '. :.� r', .. ..� .., ,k .. �,r �., .d,., sq ,q ., r �., '�1=,r �',,;!✓, ,,, ', ,, ,,,.L. .,� � ,, .,, ",b'�...,,, :..: .,..,, �i„ f „+N', f',„' �k..d� q, b.'. �,. � ,,:, A, »,. �,. ., 1 z 4 „ i \ , CY ,.✓'.'� "i d,1 5 'l. hi:r r. d :I �y#ev �� { „?;,� t ;Cm. .,,: "3 ', P �.��,1a'z '+ n•� a ':.�,. :w .. 1 Y. v :•,,�i' ::r/ w ',� g „ .,e,ar r? r,.. „'„�, ",, ','�. a.+,. .', os\. r"7�i; ,d, ”. i P k'tr ,� $ p'• .J.: �,„1 ,ro,v ..,,,, „ ! ( VAS „AS,'4� ''.. #?,e ;a'� ar, r l�,r� �� k.. 'M,d „4, r{ 4'” r, ��� f. 1e {AY. �l• } r r',,li du ,n e.•. 1 '` �iN�i'�'�"4ih�Y �i� � ■' � �, f.. ,Iv �', h°. k 1 � l'�. �I f t#P i� (�luy Ar I �ry h � r y�����;���,! r^� ��,,,?,?r N „'',�'"�{) kx r�+'�,r�P�lµ yy rP�;�,''�r y�w�,k n,r,, a�w, k ;b .; r DATE co Curry { :;.V dr ii t? S fldi / Aar i Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 71 -MC -CW a15cd 12 0.087 0.069 0.828 ZH-MC-CW @30cd 9 0.131 0.111 0.999 ZH-MC-CW c 75cd 8 ; 0.222 0.2 1.600 ZH-MC-CW @95cd 2 0.292 0.264 0.528 ZR -MC -CW cd 19 0.069 0.069 1.311 ZR -MC -CW @30cd 1 0.111 0.111 0.111 0.111 0.141 Amps 5.407 Amps Standby Current Load: 0,141 Amps For 24 Hours = 3.384 Amp -hours Alarm Current Load: 5:407 Amps For 5 Minutes= 0.454 Amp -hours 25% Derating= 4.798 Amp -hours Total System Current Load: 4.798 Amp -hours s. �A�P-'�}I Notification Appliance Circuit Detail PROJECT: QUILTS RTC Panel: EXISTING PAD -3 POWER SUPPLY Date: April 18, 2014 Wire Resistance 2.58 CURRENT TOTAL= 578.00 ZH-MC-CW @15cd Ocd 1 ZH-MC-CW ©75cd ZH-MC-CW @95cd 2 ZR-MC-CW@15cd -MC-CW @3Ocd DEVICES :5 87 871 222. 222; 292 it 69 111 TOTAL mA= ;Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E E-OLVOlt7sge WL*2)*(RJff Total Cct Load (E=I*R) 24-t 1.90 0:58 1.10 22.90 SYSTEM CALCULATIONS TO HOUSE J -BOX TO HOUSE EXISTING POWER SUPPLY S1-1 S1-2 S1-3 S1-4 S1-5 15cd 15cd 15cd 75cd 30cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4.990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE co 0 o CCCaa Z co O —I o0 0 2z 00 <t ac W 1.w w zz F-csocn dup- og wo cc CC 0 W z —J w 0 z 0 z dC C/) z O_ J Q W C!) Cf) �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/18/14 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER: 8656-1i C SHEET FA -03 TO HOUSE EXISTING POWER SUPPLY TO HOUSE J -BOX S1-1 1 5cd u ` D STOREROOM 1C2 FLOOR PLAN - FIRE ALARM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. KEYED NOTES: LINE OF SOFFIT ABOVE. Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS [REV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE -4- '' co 0 z c00o O co 0oQz ccP W w zz 1— (1) ' w= ow cc Qog 0 L11 co u.. H -GALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/18/14 BACKROUND PLAN PROVIDED BY: SOB NUMBER: 8656-11 SHEET FA -04 SHEET NUMBER LE SHEET TITLE SHEET INDEX MARINERS TEAM STORE FIRE ALARM SYSTEM TUKWILA, WASHINGTON FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLAN 117.72 Without Comments As Noted in Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. G\ By: /\ SL 1 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presentat to the Inspector prior to commencement of Acceptane Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. FUKWILA FIRE DEPARTMbto Please call: 575.4402 and give this job ind exact address for shut. icwn or restoration approval. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. '14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED SYMBOLS LEGEND QUANTITY 2 1 3 1 4 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP VERIFY IN FIELD El DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD ® SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT SMOKE p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING LIC FIRE ALARM HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING Dc FIRE ALARM HORN STROBE (WALL MOUNT) FIRE ALARM STROBE (CEILING MOUNT) ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING Pc FIRE ALARM STROBE (WALL MOUNT) FIRE ALARM SPEAKER (CEILING MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING WP FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) MR MULTI -VOLTAGE CONTROL RELAY SET -W SET -S17 -WP MR -201 /C SIEMENS SIEMENS AIR PRODUCTS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright PA 1 2 " 2009 TukwilaFire _p/ ----2P1-25-57 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z DESCRIPTION SHOP DRAWINGS DATE a) 0N N w co Or cow Cf) 17-" W 2w cc 0 co (i)cc Q w ccog V- N 0c0 t-- 4% -- ALE: 1/8"=l' } DRAWN BY: !.ANDERSON DESIGNED BY: R.VEZZANI DATE:1 /22/09 BACKROUND PLAN PROVIDED BY: .0B NUMBER: SHEET FA -01 , THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL 0 DUCT DETECTOR LOCATION END OF LINE DEVICE(3,6K 1/4W) SUPERVISED SWITCH 0 GROUND HTRI—R OSTATUS LED Co CCC) 0 0 0 N.0 COM N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL 0 waSCALE(BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 11 VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - OUTLET SAMPLING TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND 0 TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE j(+) 111 STOP IF LAST DEVICE (-) FROM XLS CONTROL PANEL ❑R PREVI❑US ADDRESSABLE DEVICE(-) END OF LINE DEVICE (3,6K 1/4W) 0 SUPERVISED SWITCH RELAY CONTACTS (4.OA @ 125VAC) GROUND (4.OA @ 30VDC) 27 VDC 3.5 mA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF (104uF 14 AWG 18 AWG NOTE 21 ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. a MEI TB1 50900 123456 HCP oWl 654321 TB2 O 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL 0 LABELSCALE(FIRE SUPPRESSION SYSTEM INTERFACE) HTRI—D OSTATUS LED 0 0 GND N AC 00 00 0 0 r1 PAD -3 0 L.] oo� INPUT INPUT TROUBLE NAC' NAC2 NAC3 NAC4 AUX 1+1- 1 2+2- 2 NC C NO + - + - + - + - + - koirm mut tinuttompuspitoizY -67 244( TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE 0 NOT USED 0 FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP ..I._ 0 0 _f FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> END OF LINE DEVICE 3.6K 1/4W) NAC -4 NAC -3 NAC -2 NAC -1 UPERVISED WITCH 470 OHMS 1w EOL N TS M-1 0 a 0 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE:NONE EARTH GROUND -0(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE HORN STROBE / STROBE WIRING DIAGRAM LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80" A.F.F. HORN/STROBE 4S DEEP BOX W/ 1-1/2" I EXTENSION RING ;(SPEAKER STROBE) 4S BOX (STROBE ONLY) WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE EDL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32' F 0' C) TO 100' Ft38' C) HUMIDITY: 93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -->.• FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPUCA1IONS OF 300-4000 FT IN WHEN USED IN CONJUNCTION NA114 DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICEE- ( ) DATA OUT (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N Nom. --HORN MOUNTED SPEAKER/STROBE N CEILING MOUNTED HORN/STROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTION BOX MOUNTED ON \ CEILING. FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT / / / / / 0 0 IL TO NEXT DEVICE CADDY BAR SMOKE DETECTOR --------- SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 1/22/09 2 \.<1.<\ �I W CX: OD OD () z w° <1C u' z z fIN 3:4t CI: w v - N CiE °0 D E- DRAWN BY: '.ANDERSON DESIGNED BY: R.VEZZANI DATE: 1 /22/09 BACKROUND PLAN PROVIDED BY: SOB NUMBER: f SHEET J FA -02,, EOL S1— NORTH 2s r I MARINERS TEAM STORE WESTFIELD SOUTHCENTER MALL SCALE 118"=1' FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACT❑R, WIRED BY ELECTRICAL CONTRACT❑R, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESION SYSTEM, FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 1 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z 4 DESCRIPTION SHOP DRAWINGS DATE 0) 0 N C4 01 « L1J CC cco O 03 W Z W° • u)zz w ww I— cc _ cn CC w U-1 ) 0 id ZCC"' N co Q ~ �CALE: 1/8" =1 ' ti. DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:1 /22/09 BACKROUND PLAN PROVIDED BY: .10B NUMBER: J 1 SHEET FA -03 macyy ,EEE Ls inervyrrs 2 LEVELS xs- i v�rr NORDSTROM 3 LEVELS TE ?V'( JCPenney :I.:r Yv5 SLAMS 5-1 F NORTH u MARINERS TEAM STORE IVESTFIELD SOUTHCENTER MALL SCALE 1132 2S 2S 2S 2S 2S 2S D C 30 C 30 15 15 15 C 15 15 EOL -S1 EX SYSTEM CALCULATIONS BATTERY SIZING CALCULATION MARINERS TEAM STORE MARINERS TEAM STORE FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS 'PROJECT: VVESTFIELD SOUTHCENTER MALL I 1.62 756 DATE 0 Panel: I Date: MARINERS TEAM January 22, 2009 STORE Iwire Resistance N Current Load: Standby: Alarm: i_ -_____. CIRCUIT: QTY 2 2 0 Current Load: Standby: Alarm: Device Type IZH-MC ©15CD 1ZH-MC@30CD Alarm Current Alarm Total 1 Wire SiZB Wre Length Voltage at EOL Circuit Total 108 2161 L 1 Device Type Total Wire Resistance (R) Qty Amps Total Amps Total - Device Type (WL * 2 )* (R/ft) Qty Amps 1ZH-MC @75CD219 Total Amps Total HFP-11 Total Device. Load, Amps (1) 0.0022 0.0022 0.0023 E _-- 0 i '(Total Cct Load AD2-P 1 0.0635 0.0635 0.064 0.064 ? Main System Board 1 0.030 0.03 0.030 0.030 HTR -R 0 ! 2 0.009600 0.0096 0.021 0.042 EOL Voltage ZH-MC-CW @15CD 20.06 2 0.108 01 0.216 0.108 0.216 (20.4 - E) HTRI-D _ �4 _ Z-MC@15CD 0.001600 _ 256i 0.0035 ZH-MC-CW @30CD 2 0.142 0 `Z-MC@30CD 0.284 0.142 0.284 1 ICP -B6 0.005 ZH-MC-CW @75CD - 20.061977281 7561 219 219 DEVICES= 8 TOTAL mA= 756. 12 138 - 0.0731 Amps 0.106 Amps ZR -MC @15CD 4 0.064 0.256 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 0.098 HCP 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.53 Amps 0.786 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.53 Amps For 24 Hours = 12.720 Amp -hours Alarm Current Load: 0.786 Amps For 5 Minutes= 0.066 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 15.983 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 15.983 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a Notification Appliance Circuit Detail DESCRIPTION SHOP DRAWINGS 'PROJECT: VVESTFIELD SOUTHCENTER MALL I 1.62 756 DATE 0 Panel: I Date: MARINERS TEAM January 22, 2009 STORE Iwire Resistance N CURRENT TOTAL= i_ -_____. CIRCUIT: QTY 2 2 0 ;S-1 --- __-._____. vv Device Type IZH-MC ©15CD 1ZH-MC@30CD Alarm Current Alarm Total 1 Wire SiZB Wre Length Voltage at EOL Circuit Total 108 2161 L 1 Total Wire Resistance (R) 0.45 142 2841 - - (WL * 2 )* (R/ft) 1ZH-MC @75CD219 01 Total Device. Load, Amps (1) ; 0.76 0 0.________.__ 0 E _-- 0 i '(Total Cct Load 0 Voltage Drop ( E) ? 0.34 0 (E= 1 * R) 0 ! 0 1 EOL Voltage 1 20.06 0____ 01 (20.4 - E) _ �4 _ Z-MC@15CD 64 _ 256i 0 `Z-MC@30CD 98 01 - 20.061977281 7561 DEVICES= 8 TOTAL mA= 756. 12 138 - 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 0 N EN o CI<CQCI 0 w C1) w C!) CC w z W C/) z 0 U J 0 w F -- C) }- ( ) �CALE: 1/8"=1' DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE:1 /22/09 RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved BACKROUND PLAN PROVIDED BY: SOB NUMBER: SHEET FA -04 } NEW SUSPENDED Ga113. CEILING. 0 +9'-0' AFF. W/ (I) 9'DIA FIXTURE, CENTERED IN DOOM 12) RCP (W FENDENT LIGHT PIXIURE6 AT CASH REGISTERS PER TENANT/ CONTRACTOR fUSFENDED Gill.. CEILING s +W-0' AFF. TO 15'-0' BEHIND LEASE LINE [ +13'-11' G.W.B. W/ RETAIL L -mtiG PER CONTR TENANT SCALE: I/8'=1'-0' Design per NFPA 13 - Ordinary Hazard Occupancy -130 sq ft per sprinkler All materials to be new, U.L. listed, and F.M. approved All heads to be a minimum of 6' apart and to be unobstructed by any means ik 4— Add Reliable Model G4A 165° Standard Response Concealed Sprinkler Heads in storefront 1/2 x 1/2 12 = Add Reliable Model FI 155° Standard Response Chrome Pendent Sprinkler Heads in sales area /2 x '/2 Total: 16 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD ROD PIPE SWIVEL RING STEEL JIMST/TRUSS HANGER DETAIL NTS c ❑ Velihou:i... ❑ As Not -:H .. - . 1 Per The -, 1..&rl These plans have been reviewed by Me Tukwila Fire : evention Bureau for conformance with current City ndards. Acceptance is subject to errors and missions which do not authorize violations of adopted andards and ordinances. The responsibility for the iequacy of design rests totally with the. designer. .'ditions, deletions or revisions to these drawings after -rt1s date will void this acceptance and wig require a resubmittal of revised drawings for subsequent approval. sinal acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bure au. Date: Date: /a--3o-O S Bre: ,rt r Li"... O P Y rJKWiLA PURE DEPARTIMIE6 Q Please call: 575.4407, and give this job No. OR -S -57-1D ?fid exact address for shuts 'lmr) or r3storatiori approv L Weld stamps must be inspected before pipe is jjhung. De not paint piping prior .'or :o byrLs atiiLr,st Lrvi. IMPORTANT NOTICE Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspectio CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 SOUTHCENTER MALL Mariner's Team Store 800 Southcenter Mall Tukwila, WA PAID [ =*_C 20 2008 ioRwlla Fire 800 SOUTHCENTER MALL ASSOCIATED PERMITS 14-F-089 09-F-021 14-S-080 14-S-077 08-S-540 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address'623"Sr"outcenter Mall #228 Suite Number: Floor: Tenant Name: Box Lunch #4530 New Tenant? ❑ - Yes 0 - No Property Owner's Name: Westfield Shopping Center Mailing Address: 633 Southcenter Mall #228, Tukwila, WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Mailing Address: 1743 First Ave S, Seattle, WA 98134 kveliz@guardiansecurity.com city State Zip E-mail Address: Fax Number: 206.374 2952 Contractor's City of Tukwila NICET II1 number: Business License number: GUARDss233K6 Exp. 09/30/2016 Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 3600 Scope of Work (please provide detailed information): Fire Alarm System Alteration: Add 1 device. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING SbWNER OR A1l/THORIZED AGENT: Signature: Date: -—(w 1 Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 800 Southcenter Mall King Co. Assessor's Tax No.: 9202470010 Suite Number: 800 Floor: New Tenant? El - Yes ❑ - No Tenant Name: Quilts ETC Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave. South, Seattle, WA 98134 kveiiz@guardiansecurity.com city E-mail Address: Fax Number: 206.628.4990 State Zip Valuation of Project (contractor's bid price): $ ' Scope of Work (please provide detailed information): Adding 12 devices to existing FRCP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING y NER-OR AUTH i ' ED AGENT: j Signature: . 4 Date: I f 21 - ` Print Name: Karina Vel Z Day Telephone: 206.349.5889 Plan Permit App.doc 5/14/10 TFD FP Form 8 44"444 IMRE SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: '1 z d ,--17-0010 Site Address: 0 (o $ SO J -1-kL211-ke ( / 5,0 GSL e g 0Suuite Number: $00 Floor:1 Tenant Name: lX 0 , 1 A'S EJ(.— — New Tenant? VI- Yes ❑ - No Property Owner's Name: J.A1 Q5-kCiel (o(7ofii4Io(\ c� Mailing Address: Z ODgSeg i(Via�fvv r �'t o �, (U �,( 1,1 i 1 A (J %� .8 1 City State Zip CONTACT PERSON -if there are questions about the submittal. 6a/ 1 Name: Ci `t5k l e OA ar\ Day Telephone: l.4 ZS— 361—t 105 Company Name: C CO) (\ C. l i- P r D G k- ion, 111 c Mailing Address: Po 60i 2- t i y(i i/ 1 if -eek t fig 980e2._ Z E-mail Address: Cr i S k ; e e c co w n f p* (0 rn City IFax Number: "1 as-- UState 1- goip 9 5 - Total number of new/relocated devices or sprinkler heads: 2 2. C I b G 12 (e 1 o ca -C) Valuation of Project (contractor's bid price): $ 5 0 0 0 I I d � I- ^ Scope of Work (please provide detailed information): A d 10 e a cis andff re 1 OL 44e /a inLtI or reads r knar#!5 OLL Du - PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: (7l', S h 0/il col d Plan Permit App.doc Date: // 6 /I Y Day Telephone: 421-L4'1-766 9. 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Quilts 800 Southcenter Mall Permit No.: 14-S-080 Date: April 22, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Mariners Team Store 800 Southcenter Mall Permit No.: 08-S-540 Date: December 30, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more heads require hydrostatic test and system isolation if necessary. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2007 Edition. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C —CLAMP WITH SET SCREW 3/8' ALL THREAD RDD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER. DETAIL NTS . FlexHeap Sprinkler Drop Corrugated stainless steel hose with stainless steel bral Tarall,kle in 2, 3',4',5' & 6Iegnths . • • . • ' • -•. • • Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart 1) REFLECTED. CFILINO:-PLAN . .1/47 :=. Multi -Port Bracket • • Adjustable Hub • , • :• FLEXIliA/3 nrerriTTETPCy. — • , ' • F.lexhead omi-rie.rcial T -Bar Ceiling Installation ' Model #2024 2036 2048 (:)60 2672 ' . c o Without Comments O As Noted -In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire lrevention Bureau for conformance with current City :tandards. Acceptance Is subject to errors and 2inissions which do not authorize violations of adopted andordirrances. The responsibility for the ,lciequacy of design reststotally with the designer. deletions or revisions to these drawings after Ifals date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. 5inal acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 1'1 By: Vie mmmm 'as mmmmmm is mmm :wilt s .le m eim.e.pminim.fts. - ill WASHINGTON STATE 1 - FIREPrOTIVAACZWICAICERESPWTENIS John J. Abel - • - - -- . ' - .- . 9760 -0591 -CG - Level 3 •- - Crown Fire Protection,.Inc. - i CR WNFP044 • ia sLIJAA11 re ff• na O tO — Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 xY2 (white) o Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 (white) CROWN FIRE PROTECTION • INCORPORATED P.O. BOK 12113 MILL CREEK, WASHINGTON 98082-0113 • PH. (425) 481-7669 m • TUKWILA FIRE DEPARTt4ENT Please call 206-575-4407 and give this Fire Permit No. /Li -S- 0 5? 0 and exact address for shut- down or restotaton approval. MALL KEY PLAN .4$,_ Vfi Nita1,441,1Kilt Li Quilts 1068 Southcenter Mall Space 800 Tukwila, WA 98188 DATE: Li DRAWN: SCALE: (/ APR 1 TUKWIL I C ID 7 2014 FIRE 'Ss FAX TRANSMITTAL 04/16/2014 11:26 4254818695 CROWN FIRE PAGE 01/01 Fax No. CROWN OWN FIE PROTECTION, INC. Ih t 4.16.14 Fire Prevention Bureau Tukwila Fire Department / ,A,1 Demo Permit Num (Including Co 1 ❑ Urgent P1 For Review 0 Please Comment 0 Please Reply 206.5754439 Cristie Ogland Prl;425.4g1.7669 • FX:425.481,8695 omments Please provide a demo pezmit to remove (5) sprinkler heads that are in the way of the framing at the Quilts's project at 1068 Southcenter Mall, Space #800. The building permit # is D13-0384. Please let us know if you have any questions. •thanks-•- TUKWILA FIRE DEPARTMENT Please call n6-575-4407 and give this Fire Permit No. l9 -S -o and exact address for shut- down or restonon approval. GtERTIj IICATE OFO sIrw NCY FIRE PROTECTION SPRINKLER SYSTEMS • John J. Abel 9760 -o591 -CG Level 3 Cro Fire Protection, Inc. Is• CR: NFP044LL P.Q. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8695 • IL � FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON Without Comments o As noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire "revention Bureau for conformance with current City standards. Acceptance is subject to errors and .missions which do not authorize violations of adopted andards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: Ll- ^ I ( 8y: % J I SHEET NUIV 3ER SHEET TITLE FA -01 SYSTEM I N FO MATT O N FA -02 TYPICAL WIRI\G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATION S AND SINGLE LINE DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX WIRE SCHEDULE AND CO\DUIT FILL CHA RT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPUFPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPUFPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPUFPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPUFPLR RED (JACKET) V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLJFPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPUFPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANG=RS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE VYITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 2 2 2 1 3 2 SYMBOL DESCRIPTION MODEL NOTICE Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the te- tinq TUKWILA FIRE DEPARTMENT` Please call 206-575-4407 and give this Fire Permit No. I �l-F-off and exact address shut- down hutdown crr res mon approval. MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP AIR DUCT HOUSING W/ SMOKE DETECTOR FDBZ492-HR W/ SIEMENS DUCT HOUSING HFP-11 DETECTOR HVAC DUCT WORKS HT -M SINGLE INPUT INTERFACE MODULE HTRI-M SIEMENS 4S BOX VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM QQ HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S BOX CEILING FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX CEILING CI JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND QUILTS ETC 800 t'yy� LI TI'E FLI CS::.42 I I si ��wF+`3:�`rti s PNC FIX �Tn4:aAs4 o t i GATE CDTs ERSTING JCPenney .LEVELS WIRE DESIGNATION GENERAL NOTES SITE PLAN FA -01 Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved J 1 PAID Q. c_ 201i PR i i .fUKVVlLA FRE l'6- 20' FAX (206) 628-499 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 03 0 2<<aaa Z co o 1- Qrn 0 ca < WO W w ZZ 65Oc CC 0 c4 U) - cc cow LL �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/18/14 BACKROUND PLAN PROVIDED BY: '0B NUMBER: 8656-1} SHEET THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 12OVAC-60HZ DEDICA1TD E,IERCENCY -( HOTS FOR ADDITIONAL SPE( CAPONS SEE PRODUCT OOCUIENTATION. *CONTACT RATINGS: 4.OA 0 125VAC 4.OA 0 30VDC TO DEVICE ADDRESSABLE TCPNEXT LAST FR[II XLS MITRE. PANEL( IR PREVIQIS ADDRESSABLE DEVICE - 0 FROM PREVIOUS ADDRESSABLE 2 DEVICE HFP-11 TB1 ®® NO COM NC 2 TO FAN SHUTDOWN EOLR ./wv, 470 SWITCH + - INPUT LED TSM -1 HTRI-M RED BLK + TO NEXT 00 ADDRESSABLE DEVICE ORG ORG GRN NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PFODUCT DOCUMENTATION. TYPICAL DUCT DETECTOR/HTRI-M MODULE/TSM-1 SWITCH WIRING DETAIL INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - 3.6k EOL C -CABLE 2 SPARE SPARE SPARE C -CABLE (-) HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY + u HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TING TEMPERA RE: +32' F (0' C) TO 100'F (38 C) HUMIDITY: 93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR — FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FTA1IN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL HARD LID CEILING �00�0► 00 SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING 7- HORN STROBE STROBE ONLY DROP CEILING MOUNTING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX �i..frrSAage4AtakAAmLAXER4MOSM. 4 C MOUNTED AGAINST CEILING SUPPORT 1 0 O TO NEXT DEVICE ---CADDY BAR SMOKE/HEAT DETECTOR \\- SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved m 0 4,2 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 1 DMG I DESCRIPTION SHOP DRAWINGS a o .d- 00 0 2 CCCCC Z o O Q U 8 �z w W wzz I- 65 6 O(i) CC od Q ci)— W 0 CC c0 LL F - z O O Z c� z SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/ 18/ 14 BACKROUND PLAN PROVIDED BY: .0B NUMBER: 8656-21 1' SHEET '' FA -02 ' < t�AF{?,•d Z''*, M'+'�`f� d� i ! V ' +� t . a'� i, � {' Fii m' " p '.:,u' 1 ya ? , Z 43t Y ,fl t ✓4 tr Y4Y ,''. . ,k '�},,t:fM1:� t"',','• r b � y� R, 4 a ry .6 'S f d h'd �, S: 1 l r! r J r y 1 {, ,, h 5'r', d, "� .}Ai,.r !?ad � v}'„ ,,,r4„:i.�a„n,.',,4 4t .: 4�,�zV„ „ •' ,'5tr, ,,., , . •A',M^ ' .. ? P�,r 9m„+ tii„�'�r � ,hpf$ Vt.�t;. �T:. a, 6 ,.., � .1., � zSt, i t R WiT, 1,, .:� � a ,... t DATE co Curry { :;.V dr ii t? Current Load: S fldi / Standby: Alarm: Device Type Device Type Qty Qty Amps Total Total Amps Total HFP-11 Detector 2 0.0015 ^ 0:0030 0.0015 0.0030 Main System Board FDBZ492 Duct Housing 1 2 0.0001 0.03 0.0002 0.0500 0.1000 71 -MC -CW a15cd HTR R Module . 12 1 0:0010 0.0010 0.0010 0.0010 ZH-MC-CW @30cd HTRI-M Module 9 2 0.0015 0.0030 0.0015 0.003 ZH-MC-CW c 75cd 8 ; 0.222 0.2 1.600 ZH-MC-CW @95cd 2 0.292 0.0072 Amps 0.1070 Amps ZR -MC -CW cd .. ,. ,,, rGr, z., >,, .", ., .7JwF . ,. 'h• ,., ,5,,w ,,.:, �' �,i '. :.� r', .. ..� .., ,k .. �,r �., .d,., sq ,q ., r �., '�1=,r �',,;!✓, ,,, ', ,, ,,,.L. .,� � ,, .,, ",b'�...,,, :..: .,..,, �i„ f „+N', f',„' �k..d� q, b.'. �,. � ,,:, A, »,. �,. ., 1 z 4 „ i \ , CY ,.✓'.'� "i d,1 5 'l. hi:r r. d :I �y#ev �� { „?;,� t ;Cm. .,,: "3 ', P �.��,1a'z '+ n•� a ':.�,. :w .. 1 Y. v :•,,�i' ::r/ w ',� g „ .,e,ar r? r,.. „'„�, ",, ','�. a.+,. .', os\. r"7�i; ,d, ”. i P k'tr ,� $ p'• .J.: �,„1 ,ro,v ..,,,, „ ! ( VAS „AS,'4� ''.. #?,e ;a'� ar, r l�,r� �� k.. 'M,d „4, r{ 4'” r, ��� f. 1e {AY. �l• } r r',,li du ,n e.•. 1 '` �iN�i'�'�"4ih�Y �i� � ■' � �, f.. ,Iv �', h°. k 1 � l'�. �I f t#P i� (�luy Ar I �ry h � r y�����;���,! r^� ��,,,?,?r N „'',�'"�{) kx r�+'�,r�P�lµ yy rP�;�,''�r y�w�,k n,r,, a�w, k ;b .; r DATE co Curry { :;.V dr ii t? S fldi / Aar i Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 71 -MC -CW a15cd 12 0.087 0.069 0.828 ZH-MC-CW @30cd 9 0.131 0.111 0.999 ZH-MC-CW c 75cd 8 ; 0.222 0.2 1.600 ZH-MC-CW @95cd 2 0.292 0.264 0.528 ZR -MC -CW cd 19 0.069 0.069 1.311 ZR -MC -CW @30cd 1 0.111 0.111 0.111 0.111 0.141 Amps 5.407 Amps Standby Current Load: 0,141 Amps For 24 Hours = 3.384 Amp -hours Alarm Current Load: 5:407 Amps For 5 Minutes= 0.454 Amp -hours 25% Derating= 4.798 Amp -hours Total System Current Load: 4.798 Amp -hours s. �A�P-'�}I Notification Appliance Circuit Detail PROJECT: QUILTS RTC Panel: EXISTING PAD -3 POWER SUPPLY Date: April 18, 2014 Wire Resistance 2.58 CURRENT TOTAL= 578.00 ZH-MC-CW @15cd Ocd 1 ZH-MC-CW ©75cd ZH-MC-CW @95cd 2 ZR-MC-CW@15cd -MC-CW @3Ocd DEVICES :5 87 871 222. 222; 292 it 69 111 TOTAL mA= ;Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E E-OLVOlt7sge WL*2)*(RJff Total Cct Load (E=I*R) 24-t 1.90 0:58 1.10 22.90 SYSTEM CALCULATIONS TO HOUSE J -BOX TO HOUSE EXISTING POWER SUPPLY S1-1 S1-2 S1-3 S1-4 S1-5 15cd 15cd 15cd 75cd 30cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4.990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE co 0 o CCCaa Z co O —I o0 0 2z 00 <t ac W 1.w w zz F-csocn dup- og wo cc CC 0 W z —J w 0 z 0 z dC C/) z O_ J Q W C!) Cf) �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/18/14 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER: 8656-1i C SHEET FA -03 TO HOUSE EXISTING POWER SUPPLY TO HOUSE J -BOX S1-1 1 5cd u ` D STOREROOM 1C2 FLOOR PLAN - FIRE ALARM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, MONITOR MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. KEYED NOTES: LINE OF SOFFIT ABOVE. Proprietary and Confidential, Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS [REV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE -4- '' co 0 z c00o O co 0oQz ccP W w zz 1— (1) ' w= ow cc Qog 0 L11 co u.. H -GALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/18/14 BACKROUND PLAN PROVIDED BY: SOB NUMBER: 8656-11 SHEET FA -04 SHEET NUMBER LE SHEET TITLE SHEET INDEX MARINERS TEAM STORE FIRE ALARM SYSTEM TUKWILA, WASHINGTON FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLAN 117.72 Without Comments As Noted in Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. G\ By: /\ SL 1 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presentat to the Inspector prior to commencement of Acceptane Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. FUKWILA FIRE DEPARTMbto Please call: 575.4402 and give this job ind exact address for shut. icwn or restoration approval. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. '14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED SYMBOLS LEGEND QUANTITY 2 1 3 1 4 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP VERIFY IN FIELD El DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD ® SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT SMOKE p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING LIC FIRE ALARM HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING Dc FIRE ALARM HORN STROBE (WALL MOUNT) FIRE ALARM STROBE (CEILING MOUNT) ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING Pc FIRE ALARM STROBE (WALL MOUNT) FIRE ALARM SPEAKER (CEILING MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING WP FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) MR MULTI -VOLTAGE CONTROL RELAY SET -W SET -S17 -WP MR -201 /C SIEMENS SIEMENS AIR PRODUCTS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright PA 1 2 " 2009 TukwilaFire _p/ ----2P1-25-57 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z DESCRIPTION SHOP DRAWINGS DATE a) 0N N w co Or cow Cf) 17-" W 2w cc 0 co (i)cc Q w ccog V- N 0c0 t-- 4% -- ALE: 1/8"=l' } DRAWN BY: !.ANDERSON DESIGNED BY: R.VEZZANI DATE:1 /22/09 BACKROUND PLAN PROVIDED BY: .0B NUMBER: SHEET FA -01 , THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL 0 DUCT DETECTOR LOCATION END OF LINE DEVICE(3,6K 1/4W) SUPERVISED SWITCH 0 GROUND HTRI—R OSTATUS LED Co CCC) 0 0 0 N.0 COM N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL 0 waSCALE(BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 11 VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - OUTLET SAMPLING TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND 0 TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE j(+) 111 STOP IF LAST DEVICE (-) FROM XLS CONTROL PANEL ❑R PREVI❑US ADDRESSABLE DEVICE(-) END OF LINE DEVICE (3,6K 1/4W) 0 SUPERVISED SWITCH RELAY CONTACTS (4.OA @ 125VAC) GROUND (4.OA @ 30VDC) 27 VDC 3.5 mA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF (104uF 14 AWG 18 AWG NOTE 21 ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. a MEI TB1 50900 123456 HCP oWl 654321 TB2 O 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL 0 LABELSCALE(FIRE SUPPRESSION SYSTEM INTERFACE) HTRI—D OSTATUS LED 0 0 GND N AC 00 00 0 0 r1 PAD -3 0 L.] oo� INPUT INPUT TROUBLE NAC' NAC2 NAC3 NAC4 AUX 1+1- 1 2+2- 2 NC C NO + - + - + - + - + - koirm mut tinuttompuspitoizY -67 244( TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE 0 NOT USED 0 FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP ..I._ 0 0 _f FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> END OF LINE DEVICE 3.6K 1/4W) NAC -4 NAC -3 NAC -2 NAC -1 UPERVISED WITCH 470 OHMS 1w EOL N TS M-1 0 a 0 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE:NONE EARTH GROUND -0(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE HORN STROBE / STROBE WIRING DIAGRAM LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80" A.F.F. HORN/STROBE 4S DEEP BOX W/ 1-1/2" I EXTENSION RING ;(SPEAKER STROBE) 4S BOX (STROBE ONLY) WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE EDL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32' F 0' C) TO 100' Ft38' C) HUMIDITY: 93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -->.• FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPUCA1IONS OF 300-4000 FT IN WHEN USED IN CONJUNCTION NA114 DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICEE- ( ) DATA OUT (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N Nom. --HORN MOUNTED SPEAKER/STROBE N CEILING MOUNTED HORN/STROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTION BOX MOUNTED ON \ CEILING. FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT / / / / / 0 0 IL TO NEXT DEVICE CADDY BAR SMOKE DETECTOR --------- SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 1/22/09 2 \.<1.<\ �I W CX: OD OD () z w° <1C u' z z fIN 3:4t CI: w v - N CiE °0 D E- DRAWN BY: '.ANDERSON DESIGNED BY: R.VEZZANI DATE: 1 /22/09 BACKROUND PLAN PROVIDED BY: SOB NUMBER: f SHEET J FA -02,, EOL S1— NORTH 2s r I MARINERS TEAM STORE WESTFIELD SOUTHCENTER MALL SCALE 118"=1' FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACT❑R, WIRED BY ELECTRICAL CONTRACT❑R, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESION SYSTEM, FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 1 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z 4 DESCRIPTION SHOP DRAWINGS DATE 0) 0 N C4 01 « L1J CC cco O 03 W Z W° • u)zz w ww I— cc _ cn CC w U-1 ) 0 id ZCC"' N co Q ~ �CALE: 1/8" =1 ' ti. DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:1 /22/09 BACKROUND PLAN PROVIDED BY: .10B NUMBER: J 1 SHEET FA -03 macyy ,EEE Ls inervyrrs 2 LEVELS xs- i v�rr NORDSTROM 3 LEVELS TE ?V'( JCPenney :I.:r Yv5 SLAMS 5-1 F NORTH u MARINERS TEAM STORE IVESTFIELD SOUTHCENTER MALL SCALE 1132 2S 2S 2S 2S 2S 2S D C 30 C 30 15 15 15 C 15 15 EOL -S1 EX SYSTEM CALCULATIONS BATTERY SIZING CALCULATION MARINERS TEAM STORE MARINERS TEAM STORE FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS 'PROJECT: VVESTFIELD SOUTHCENTER MALL I 1.62 756 DATE 0 Panel: I Date: MARINERS TEAM January 22, 2009 STORE Iwire Resistance N Current Load: Standby: Alarm: i_ -_____. CIRCUIT: QTY 2 2 0 Current Load: Standby: Alarm: Device Type IZH-MC ©15CD 1ZH-MC@30CD Alarm Current Alarm Total 1 Wire SiZB Wre Length Voltage at EOL Circuit Total 108 2161 L 1 Device Type Total Wire Resistance (R) Qty Amps Total Amps Total - Device Type (WL * 2 )* (R/ft) Qty Amps 1ZH-MC @75CD219 Total Amps Total HFP-11 Total Device. Load, Amps (1) 0.0022 0.0022 0.0023 E _-- 0 i '(Total Cct Load AD2-P 1 0.0635 0.0635 0.064 0.064 ? Main System Board 1 0.030 0.03 0.030 0.030 HTR -R 0 ! 2 0.009600 0.0096 0.021 0.042 EOL Voltage ZH-MC-CW @15CD 20.06 2 0.108 01 0.216 0.108 0.216 (20.4 - E) HTRI-D _ �4 _ Z-MC@15CD 0.001600 _ 256i 0.0035 ZH-MC-CW @30CD 2 0.142 0 `Z-MC@30CD 0.284 0.142 0.284 1 ICP -B6 0.005 ZH-MC-CW @75CD - 20.061977281 7561 219 219 DEVICES= 8 TOTAL mA= 756. 12 138 - 0.0731 Amps 0.106 Amps ZR -MC @15CD 4 0.064 0.256 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 0.098 HCP 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.53 Amps 0.786 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.53 Amps For 24 Hours = 12.720 Amp -hours Alarm Current Load: 0.786 Amps For 5 Minutes= 0.066 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 15.983 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 15.983 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a Notification Appliance Circuit Detail DESCRIPTION SHOP DRAWINGS 'PROJECT: VVESTFIELD SOUTHCENTER MALL I 1.62 756 DATE 0 Panel: I Date: MARINERS TEAM January 22, 2009 STORE Iwire Resistance N CURRENT TOTAL= i_ -_____. CIRCUIT: QTY 2 2 0 ;S-1 --- __-._____. vv Device Type IZH-MC ©15CD 1ZH-MC@30CD Alarm Current Alarm Total 1 Wire SiZB Wre Length Voltage at EOL Circuit Total 108 2161 L 1 Total Wire Resistance (R) 0.45 142 2841 - - (WL * 2 )* (R/ft) 1ZH-MC @75CD219 01 Total Device. Load, Amps (1) ; 0.76 0 0.________.__ 0 E _-- 0 i '(Total Cct Load 0 Voltage Drop ( E) ? 0.34 0 (E= 1 * R) 0 ! 0 1 EOL Voltage 1 20.06 0____ 01 (20.4 - E) _ �4 _ Z-MC@15CD 64 _ 256i 0 `Z-MC@30CD 98 01 - 20.061977281 7561 DEVICES= 8 TOTAL mA= 756. 12 138 - 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 0 N EN o CI<CQCI 0 w C1) w C!) CC w z W C/) z 0 U J 0 w F -- C) }- ( ) �CALE: 1/8"=1' DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE:1 /22/09 RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved BACKROUND PLAN PROVIDED BY: SOB NUMBER: SHEET FA -04 } NEW SUSPENDED Ga113. CEILING. 0 +9'-0' AFF. W/ (I) 9'DIA FIXTURE, CENTERED IN DOOM 12) RCP (W FENDENT LIGHT PIXIURE6 AT CASH REGISTERS PER TENANT/ CONTRACTOR fUSFENDED Gill.. CEILING s +W-0' AFF. TO 15'-0' BEHIND LEASE LINE [ +13'-11' G.W.B. W/ RETAIL L -mtiG PER CONTR TENANT SCALE: I/8'=1'-0' Design per NFPA 13 - Ordinary Hazard Occupancy -130 sq ft per sprinkler All materials to be new, U.L. listed, and F.M. approved All heads to be a minimum of 6' apart and to be unobstructed by any means ik 4— Add Reliable Model G4A 165° Standard Response Concealed Sprinkler Heads in storefront 1/2 x 1/2 12 = Add Reliable Model FI 155° Standard Response Chrome Pendent Sprinkler Heads in sales area /2 x '/2 Total: 16 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD ROD PIPE SWIVEL RING STEEL JIMST/TRUSS HANGER DETAIL NTS c ❑ Velihou:i... ❑ As Not -:H .. - . 1 Per The -, 1..&rl These plans have been reviewed by Me Tukwila Fire : evention Bureau for conformance with current City ndards. Acceptance is subject to errors and missions which do not authorize violations of adopted andards and ordinances. The responsibility for the iequacy of design rests totally with the. designer. .'ditions, deletions or revisions to these drawings after -rt1s date will void this acceptance and wig require a resubmittal of revised drawings for subsequent approval. sinal acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bure au. Date: Date: /a--3o-O S Bre: ,rt r Li"... O P Y rJKWiLA PURE DEPARTIMIE6 Q Please call: 575.4407, and give this job No. OR -S -57-1D ?fid exact address for shuts 'lmr) or r3storatiori approv L Weld stamps must be inspected before pipe is jjhung. De not paint piping prior .'or :o byrLs atiiLr,st Lrvi. IMPORTANT NOTICE Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspectio CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 SOUTHCENTER MALL Mariner's Team Store 800 Southcenter Mall Tukwila, WA PAID [ =*_C 20 2008 ioRwlla Fire