Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 801 SOUTHCENTER MALL - APPLE COMPUTER INC - PERMITS AND PLANS
801 SOUTHCENTER MALL ASSOCIATED PERMITS 19-F-242 19-F-230 13-F-291 13-F-084 08-F-459 08-S-454 08-S-384 SITE LOCATION 9202470010 King Co. Assessor's Tax No.: Site Address: outhcenter Mall, Tukwila, 98188 Suite Number: Floor: Tenant Name: f V New Tenant? El - Yes ❑ - No Pro a owner's Name: Westfield Property ax Dept. p r'h Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 E-mail Address: kveliz@guardiansecurity.com Total number of new/relocated devices or sprinkler heads City State Zip Fax Number: 206.628.4990 Valuation of Project (contractor's bid price): %' a Scope of Work (please provide detailed information): Low Voltage: Installing New HVAC Unit. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING I Old AUTHO ' ; AGENT: Signature: Date: Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 44"444 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 4MM I�Il2`�q FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Site Address: t Tenant Name: ��r _,, at, p Property Owner's Name: \3 V 4 WlS Mailing Address ��CG **PLEASE PRINT** King Co. Assessor's Tax No.: ` CAtk(OO ( t Suite Number: e(p Floor: New Tenant? ❑ - Yes [a.- No C' K\A`cnA cvnk3 CONTACT PERSON -if there are questions about the submittal. City State Zip Name (QA.Thi% ()AI� 11Day Telephone( ) ; �p Company Name: 1OS C&Y& `--)Q.00C Mailing Address:\1 J \* ��(�' , %j \i4F 144k.7.)4 - City State Zip E-mail Addressi ATU �k(�iY hai300Q,1IQAa �kO tX(\ Fax Number: �f J `Contractor's City of Tukwila n NICET III number: Business License number:. c) -4 , Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $A.1��r5 — Scope of Work (please provide detailed information): ' (1 \CkX \ 4j i ' , c ,Q)Acu„A cx-oq, ` \-k(odAut ( 1 )cit% lcki. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ'AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O ER OR AUTHORIZED AGENT: e: Signatur 0�� 1i Date.1 `! 1 a] ( q Print Name: jaq,,P, V\ Day Telephone: (2. (.U) CQ19 - 3 Plan Permit App.doc 8/22/14 TFD FP Fonn 8 GUARDIAN SECURITY Customer LIFE AND PROPERTY PROTECTION Apple 801 SOUTHCENTER MALL TUKWILA, WA 98188 I —.sect Apple Project # List of Materials Vendor Guardian Security Systems Inc 1743 1st Ave. South Seattle, WA 98134 Phone #: (206)622-6545 Fax #: (206)628-4990 Type of Equipment FIRE ALARM Date: Sept,08,08 Item Qty. Manuf. Model Description Unit Pri Total Price 1) Siemens PAD -3 2) Siemens AD2-P 3) Siemens HTRI-D 4) Siemens HTRI-R 5) Siemens ZH CW,W 6) Siemens ZR-MC-W,W 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) t1) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) 33) 34) 35) 36) 37) 38) 39) 40) 41) 42) 43) 44) 45) 46) 47) 48) 49) 50) Power Supply for Strobes with Standby" Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 Supervised Addressable Input Module Supervised Addressable Output Relay Module Interior Audible Horn Strobe Annunciator Interior Visual Strobe Annunciator Conduit Systems: All smoke removal and detection and control devices in an approved metallic raceway and all devices in conduit per Standard I XI 18 08 10:09a NW Fire Systems I UKWILA FIRE DEPART:UL1111, PI a give this job N.. o g_S 32L1 a exact address' for shut, o n or r9st3ratiorl ao rO4A vPvrf I insp hun prior appr NOVICE LUti / 12 bU4 p.� AREA OF WORK ainisnryr; Cr' stamps must, aped before pipe is . Mint paintirpipinti'�. to hydro tate test )VOL _1 } MALL CUT do GROOVE EXISTING 31/2" i RISE UP CROSSMAIN K lMthout Comments 1; Doted In Red 0 Per The Attached Letter i ti...eneen. nese plans have been reviewed by The Tt.kwila Fire Qrev4ntion Bureau tor conror;rance v,:tr cu rent city standards. Apaice is tc ericis pnd omissions which dD not dut'torze vio:3tic-.s :.:f adopted standards and or l,rlances. PIE !e ;;>r4 -., , t� for the adequacy of desiq re 15 ner. Additions, deletions or ; ev.sioris �'_: '";s• :e dniwtr,gs i ?r Thi Pwill void t?"i., ._x_�F• ;tl!icc= lU v ii require a resubmittal of reviled irawsnngs for s:ub equ:nt approval. Final acceptance Ira subject to f;eld test and nspection by The Tukwila Fire Prevention Bureau. Date: 7^i By: LASTING 311:" CROSSM N \' NEW 8 BEAM l EXISTING MAIN AT 12'-101. BOTTOM MAIN TO BE RAISED TO MAINTAIN 13'-3" BOTTOM MIN. ROTATE MAIN 90 5O RIFTING SIDE OUTLETS FACE UP — RECUT 1" 8::1W PIPE TO RECONNECT RELOCATION PLAN SCALE: 1/8" = I®HTIWESlfldf SYStMMSfIB 406 Steven AMMO NLA, Re tan, WA 98057 2067727602 • I z 206272.7504 IP V.nwlirssrd.mstom • LK 15 NORTHFS92aCR IIMININIIIMMINIP011111.0.311111011~111111001.ir <1.000•10114 T iririir /ALIVIli 7/ 8c GENERAL NOTES SCOPE OF WORK: RAISE EXISTING CROSSMAIN FOR NEW TENANT CEILING ALL WORK PER N.F.P.. f13 STANDARDS ALL MATERIALS SHALL BE NEW AND U.L LISTED OR F.M. APPROVED ARE SPRINKLER SYSTEM 1O BE INSTALLED. BRACED AND TESTED IN ACCOURDANCE 11(1H N.F.P.A. X13 WESTF1ELD MALL -- APPLE STORE 801 S011THC N1ER MALI TUKW A, WASHINGTON, 98188 DATE: 7-08 DRAWN: G.B. SCALE: AS NOTED 1 OF 1 FILM Cnpy w 1 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Apple Store 801 Southcenter Mall Permit No.: 08-S-454 Date: September 16, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • These conditions apply to any sprinkler piping exposed as necessary to accomplish the permitted scope of work. All references are NFPA 13, 2007 Edition. flZOflFfl6IflRIfl6 15 September 2008 Niki Rhodes Cosco Fire Protection 15000 Woodinville -Redmond Rd NE Woodinville, WA 98072 Tuazon Engineerin% PLLC 4322 NE 7 Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com RE: Westfield Mall — Apple Store Independent Third Party Review — Fire Sprinkler System Dear Niki: As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. The following was reviewed: • Fire Sprinkler Drawing — Sheet FS -1 dated 8-25-08 • Hydraulic Calculations • Product Data The documents were reviewed for compliance with 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. Hydraulic reference nodes should be added to the plans in accordance with NFPA 13 Para 22.1.3.(34). 2. Revise general note 1 to list "City of Tukwila" requirements. A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or ericauazon.com with any questions regarding this review. Respectfully, TIJAZON ENGINEERING, PLLC Eric P. Tuazon, PE Fire Protection Engineer C `,Gummy Fb910013PyecM2008 16 Cam - WstlW Apple Sbidl 5cepos Wan aniUswow eke Jul 18 08 10:09a ' NW Fire Systems NORTHWEST FIRE SYSTEMS SPRINKLER & EIRE ALARM 2067727504 Saving Lives, Protecting Property Fax Transmission Cover Sheet p.1 This facsimile transmission may contain confidential and/or attorney/client privileged information belonging to the sender. This information is intended only for the use of the individual or entity named on this transmission sheet. If you are not the intended recipient, or the employee or agent responsible to the intended recipient, you should return to sender immediately. You are hereby notified that any disclosure, copying, distribution or the taking of any action m reliance on the contents of this telecopied information is strictly prohibited. • Fire Sprinkler Systems Date: July 18, 2008 • Fire FA:imiuishers Company: Tukwila Fire Department • l.:nzergency IAttention: Fire Sprinkler Plan Reviewer • Installation Fax No.: 206-575-4439 • Inspection From: Clark Potter at Northwest Fire Systems LLC • Repair Subject: Main relocation and shutdown at Westfield Mall • 13a6.11ow Preventors No. of Pages (including coversheet) 2 • l laxard Analysis Hello, • Systems I)esi n. Modification. & Specification • ('orrosion Control I called yesterday and spoke with the receptionist regarding this small system modification at the front of what is going to be the new Apple Store at Westfield Shopping Center. We put together a small drawing showing the raising of the 3-1/2 inch main at the front of the store to get the height up about 1 foot higher. Please let me know if this works or if you need anything else in order for us to do this work. Clark Potter 406 Stevens Avenue NW, Renton, WA 98057 • Office: 206.772.7502 • Fax: 206.772.7504 • www.nwfiresystems.com _ _ _ Fire Protection by Computer Design COSCO FIRE PROTECTION 15000 WOODINVILLE-REDMOND RD. SUITE B-800 WOODINVILLE, WA. 98072 425-686-6300 Job Name : SD6028-APPLE STORE SOUTI-(CENTER Building : SouthCenter Mall - Tukwila, WA Location : Space #548 System : TIE to EXIST. Contract : 25SD6028 Data File : SD6028 C.wx1 COSCO FIRE PROTECTION Page 1 SD6028-APPLE STORE SOUTHCENTER Date 082808 Hydraulic Design Information Sheet Name - Apple Store Location - Space #548 Building - SouthCenter Mall - Tukwila, WA Contractor - Cosco Fire Protection Calculated By - T.N.Rhodes Construction: ( ) Combustible (X) Non -Combustible Occupancy - Ordinary Hazard for Mercantile S Y S T E M D E S I G N Date - 8-28-08 System No. - TIE to EXIST. Contract No. - 25SD6028 Drawing No. - FS -1 (loft) Ceiling Height - 11'-0" (x) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve Other Add additional Flow as required to make demand meet 650 gpm. Specific Ruling Made By Tukwila Date Area of Sprinkler Operation Density Area Per Sprinkler Elevation at Highest Outlet Hose Allowance - Inside Rack Sprinkler Allowance Hose Allowance - Outside Note - 1500 - .20 - 113 - 11.00 - 0 - 0 - 0 System Type ( ) Wet ( ) Dry ( ) Deluge ( ) Preaction ( ) Other Sprinkler/Nozzle Make Victaulic Model V2700 Size 1/2 K -Factor 5.6 Temp.Rat.155 6'-0" Flex Drops = 28 eq. ft. Calculation Flow Required - 900.75 Press Required - 66.402 SRC Summary C -Factor Used: 120 Overhead 120 Underground W Water Flow Test: A Date of Test T Time of Test E Static Press R Residual Press Flow S Elevation U 140 20 10900 0 Pump Data: Rated Cap.- @ Press - Elev. - Tank or Reservoir: Cap. - Elev.- Well Proof Flow P Location - P L Source of Information - Y C Commodity O Storage Ht. M Storage Method: M Solid Piled Class Area Location Aisle W. Palletized o Rack ( ) Single Row S R ( ) Double Row T A ( ) Mult. Row O C R K Flue Spacing A Longitudinal G ( ) Conven. Pallet ( ) Slave Pallet ( ) Auto. Storage ( ) Encap. ( ) Solid Shelf ( ) Non ( ) Open Shelf Clearance:Storage to Ceiling Transverse E Horizontal Barriers Provided: Water Supply Curve (C) W 1— Z Z 0 1— C.) III LU CC 0I- U aJ w0 rxa LL Q Oc U U Op U V) N tp f6 N O z - N C u Q.' c 0 c B E E0 E E rn f6 N N 'D N N f0 N W � Q 0 T Tvv 2 W (/) V) (/) T y y 412 '—NN 0 0 1p 2000220V) E N 0 c1 D2 r , C2 �.w,..D1...... � .... I .... � .... I' .... . . . . . . . 1 . . . . . . . . . `. . . . . . . . . . . . . . 1 . . . . 150jb WA% ndf500 6000 7500 9000 10500 12000 13500 FLOW (NA1.85) 0 0 0 0 0 0 )() M N 0 0 O 0 0 (O 0 0 0 COCM 0 d 0 W U (A 0 W O N O now Diagram COSCO FIRE PROTECTION Page 3 SD6028-APPLE STORE SOUTHCENTER Date 082808 70.1 22.9 S3 2 ->1->S2->S1 46.7 1 70.1 1 47.4 S5 4 ->3 ->S4 % 23.5 1 117.4 1 69.2 22.6 S8 6 - 5 -> S7 -. S6 46.2 1 186.6 1 70.4 23 S11 8 - 7 - S10-> S9 47 1 257 1 72.5 23.7 S14 10 9 -> S13-> S12 ? 48.4 329.5 1 26.2 26.2 12 -->11 .16 -> S15 26.2 355.7 13 650 TEST Fittings Used Summary CC W 1- z W U 2 H Z 00 F= U W 01- CC CO aJ W 0 cc d LL < 0c6 U N 00 U (/) N O N co CO v 0 W 10 M N d a m aCi z J • C lL Q CO ( r 0 ✓ CO I"- O N (0 N 0 N 10 0 0 • M 'Cr 0 � M fV 10 • N 0 0 N O O N V aD Mt0 N V) N N CO WI - Units Summary U w cC y G � 0 CTQ C a 0 • N CD C 0L:d c c u, c d 0 E 2 N c o 2 O3 LT 0_ Pressure / Flow Summary - STANDARD COSCO FIRE PROTECTION Page 5 SD6028-APPLE STORE SOUTHCENTER Date 082808 Node Elevation K -Fact Pt Pn Flow Density Area Press No. Actual Actual Req. D001 11.0 5.6 16.29 na S5 11.0 K = K @ EQ01 23.66 na S8 11.0 K = K @ EQ01 22.0 na S11 11.0 K = K @ EQ01 22.77 na S14 11.0 K = K @ EQ01 24.16 na S3 9.0 K = K @ EQ01 22.58 na S4 11.0 K = K @ EQ01 22.89 na 3 14.66 23.69 na S6 11.0 K = K @ EQ01 21.18 na S7 11.0 K = K @ EQ01 23.03 na 5 14.66 22.78 na S9 11.0 K = K @ EQ01 21.92 na S10 11.0 K = K @ EQ01 23.83 na 7 14.66 23.63 na S12 11.0 K = K @ EQ01 23.26 na S13 11.0 K = K @ EQ01 25.28 na 9 14.66 25.15 na S15 11.0 K = K @ EQ01 28.47 na 16 11.0 30.9 na 11 14.66 29.78 na S1 9.0 K = K @ EQ01 21.74 na S2 8.91 K = K @ EQ01 23.55 na 1 14.66 22.43 na 2 14.08 24.91 na 4 14.08 25.02 na 6 14.08 25.22 na 8 14.08 26.13 na 10 14.08 27.78 na 12 14.08 30.4 na 13 14.08 59.92 na +FLO 0.0 66.37 na TEST 0.0 66.4 na The maximum velocity is 20.93 and it occurs in the pipe between nodes 12 and 13 22.6 23.89 23.03 23.43 24.14 23.33 23.5 22.6 23.57 22.99 23.97 23.68 24.69 26.2 22.89 23.83 295.0 250.0 0.2 113 7.0 Final Calculations - Hazen -Williams COSCO FIRE PROTECTION Page 6 SD6028-APPLE STORE SOUTHCENTER Date 082808 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes D001 22.60 1.049 1E 2.0 28.000 16.287 to 120 0.0 2.000 0.0 EQ01 22.6 0.1631 0.0 30.000 4.894 K Factor = 5.60 Vel = 8.39 0.0 22.60 21.181 K Factor = 4.91 *P-6 S5 23.89 1.049 1T 5.0 3.910 23.664 to 120 0.0 5.000 -1.585 3 23.89 0.1807 0.0 8.910 1.610 K Factor @ node EQ01 Vel = 8.87 0.0 23.89 23.689 K Factor = 4.91 *P-9 S8 23.03 1.049 1T 5.0 9.000 22.004 to 120 0.0 5.000 -1.585 5 23.03 0.1690 0.0 14.000 2.366 K Factor @ node EQ01 Vel = 8.55 0.0 23.03 22.785 K Factor = 4.82 *P-12 S11 23.43 1.049 1T 5.0 9.000 22.771 to 120 0.0 5.000 -1.585 7 23.43 0.1744 0.0 14.000 2.442 K Factor @ node EQ01 Vel = 8.70 0.0 23.43 23.628 K Factor = 4.82 *P-15 S14 24.14 1.049 1T 5.0 9.000 24.159 to 120 0.0 5.000 -1.585 9 24.14 0.1842 0.0 14.000 2.579 K Factor @ node EQ01 Vel = 8.96 0.0 24.14 25.153 K Factor = 4.81 *P-18 S3 23.33 1.049 1T 5.0 8.290 22.581 to 120 0.0 5.000 -2.451 1 23.33 0.1731 0.0 13.290 2.300 K Factor @ node EQ01 Vel = 8.66 0.0 23.33 22.430 K Factor = 4.93 *P-21 S4 23.50 1.049 1T 5.0 8.580 22.893 to 120 0.0 5.000 -1.585 3 23.5 0.1753 0.0 13.580 2.381 K Factor @ node EQ01 Vel = 8.72 3 23.88 1.38 1T 6.0 0.410 23.689 to 120 0.0 6.000 0.251 4 47.38 0.1688 0.0 6.410 1.082 Vel = 10.16 0.0 47.38 25.022 K Factor = 9.47 *P-24 S6 22.60 1.049 0.0 11.330 21.181 to 120 0.0 0.0 0.0 S7 22.6 0.1632 0.0 11.330 1.849 K Factor @ node EQ01 Vel = 8.39 S7 23.57 1.38 1T 6.0 2.330 23.030 to 120 0.0 6.000 -1.585 5 46.17 0.1609 0.0 8.330 1.340 K Factor @ node EQ01 Vel = 9.90 5 23.03 1.38 1T 6.0 0.410 22.785 to 120 0.0 6.000 0.251 6 69.2 0.3401 0.0 6.410 2.180 Vel = 14.84 Iinal Calculations - Standard COSCO FIRE PROTECTION Page 7 SD6028-APPLE STORE SOUTHCENTER Date 082808 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes 0.0 69.20 25.216 K Factor = 13.78 *P-27 S9 22.99 1.049 0.0 11.330 21.922 to 120 0.0 0.0 0.0 S10 22.99 0.1684 0.0 11.330 1.908 K Factor @ node EQ01 Vel = 8.53 S10 23.97 1.38 1T 6.0 2.330 23.830 to 120 0.0 6.000 -1.585 7 46.96 0.1660 0.0 8.330 1.383 K Factor @ node EQ01 Vel = 10.07 7 23.44 1.38 1T 6.0 0.410 23.628 to 120 0.0 6.000 0.251 8 70.4 0.3512 0.0 6.410 2.251 Vel = 15.10 0.0 70.40 26.130 K Factor = 13.77 *P-30 S12 23.68 1.049 0.0 11.330 23.262 to 120 0.0 0.0 0.0 S13 23.68 0.1779 0.0 11.330 2.016 K Factor @ node EQ01 Vel = 8.79 S13 24.69 1.38 1T 6.0 2.330 25.278 to 120 0.0 6.000 -1.585 9 48.37 0.1753 0.0 8.330 1.460 K Factor @ node EQ01 Vel = 10.38 9 24.14 1.38 1T 6.0 0.410 25.153 to 120 0.0 6.000 0.251 10 72.51 0.3710 0.0 6.410 2.378 Vel = 15.55 0.0 72.51 27.782 K Factor = 13.76 *P-33 S15 26.20 1.049 0.0 11.330 28.470 to 120 0.0 ' 0.0 0.0 16 26.2 0.2145 0.0 11.330 2.430 K Factor @ node EQ01 Vel = 9.73 16 0.0 1.38 1T 6.0 2.330 30.900 to 120 0.0 6.000 -1.585 11 26.2 0.0563 0.0 8.330 0.469 Vel = 5.62 11 0.0 1.38 1T 6.0 0.410 29.784 to 120 0.0 6.000 0.251 12 26.2 0.0565 0.0 6.410 0.362 Vel = 5.62 0.0 26.20 30.397 K Factor = 4.75 *P-36 S1 22.89 1.049 0.0 10.620 21.737 to 120 0.0 0.0 0.039 S2 22.89 0.1671 0.0 10.620 1.775 K Factor @ node EQ01 Vel = 8.50 S2 23.83 1.38 1T 6.0 2.330 23.551 to 120 0.0 6.000 -2.490 1 46.72 0.1643 0.0 8.330 1.369 K Factor @ node EQ01 Vel = 10.02 1 23.34 1.38 1T 6.0 0.410 22.430 to 120 0.0 6.000 0.251 2 70.06 0.3480 0.0 6.410 2.231 Vel = 15.03 2 to 4 0.0 70.06 2.635 120 0.0149 0.0 0.0 0.0 7.370 0.0 7.370 24.912 0.0 0.110 Vel = 4.12 4 47.38 2.635 0.0 5.000 25.022 to 120 0.0 0.0 0.0 6 117.44 0.0388 0.0 5.000 0.194 Vel = 6.91 ' . . final Calculations - Standard COSCO FIRE PROTECTION Page 8 SD6028-APPLE STORE SOUTHCENTER Date 082808 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes 6 69.20 2.635 0.0 10.000 25.216 to 120 0.0 0.0 0.0 8 186.64 0.0914 0.0 10.000 0.914 Vel = 10.98 8 70.40 2.635 0.0 10.000 26.130 to 120 0.0 0.0 0.0 10 257.04 0.1652 0.0 10.000 1.652 Vel = 15.12 10 72.51 2.635 0.0 10.000 27.782 to 120 0.0 0.0 0.0 12 329.55 0.2615 0.0 10.000 2.615 Vel = 19.39 12 26.20 2.635 1T 16.474 81.500 30.397 to 120 0.0 16.474 0.0 13 355.75 0.3014 0.0 97.974 29.525 Vel = 20.93 13 0.0 8.249 1E 21.141 276.120 59.922 to 120 0.0 21.141 6.098 +FLO 355.75 0.0012 0.0 297.261 0.345 Vel = 2.14 +FLO 295.00 8.249 0.0 10.500 66.365 to 120 0.0 0.0 0.0 TEST 650.75 0.0035 0.0 10.500 0.037 Qa = 295.00 Vel = 3.91 250.00 Qa = 250.00 900.75 66.402 K Factor = 110.54 WSCM APPLE STORE 106 FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \UM 3ER SHEET TITLE FA -01 SYSTEIv I FOMATION/TYPICAL WRING AND MOUNTING DETAILS FA -02 SYSTEM CALCULATIONS (GENEAL), RISE SITE PLAN FA -03 FIRE ALARM SYSTEM FLOO PLAN SCOPE OF WORK ADDITIONAL MAG LOCK RELAY TO FIRE ALARM SYSTEM. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIAT❑R TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO 1#18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDIO TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO 4114 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.0. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END TYPICAL WIRING AND MOUNTING DETAILS 0 DATA OUT DATA IN 0 END OF LINE DEVICE SUPERVISED SWITCH 0 0 0 HTRI-R ()STATUS LED N.O. COM N.C. 0 0 0 //1/1 GROUND NOT SHIELD 7 FROM FACP 24 VDC DOOR MAG LOCK • 410 • • 410 DOOR MAG LOC • FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTFORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE -MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NEPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDU\IDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (-4 FT) WHERE THE CABLE IS INSTALLED Q QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL EX (EXISTING) XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY EX (EXISTING) PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP 1 HT -R RELAY INPUT INTERFACE MODULE HTRI-R SIEMENS 4S BOX VERIFY LOCATION IN FIELD 2(E) 1(E) 2(E) 7(E) 2(E) EX 1srI WITH RELAY EX (EXISTING) DUAL INPUT INTERFACE MODULE HTRI-R SIEMENS 4S DEEP VERIFY IN FIELD HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD Io< LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD 6 SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE DETECTOR ❑ EX (EXISTING) AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING LJC EX EX FIRE ALARM SPEAKER STROBE CEILING MOUNT) EXISTING IRE ALARM PEAKER STROBE WALL MOUNT) EXISTING) FIRE ALARM STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING ZH-MC-W SIEMENS 4S DEEP BOX 80" A.FE. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX CEILING W/ 1G RING L EX Y c FIRE ALARM TROBE WALL MOUNT) EXISTING FIRE ALARM SPEAKER (CEILING MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. IB3 wp FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD E l MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F,B.❑. F.B.❑. N/A VERIFY IN FIELD A.F,F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A 11/A N/ BLUE AS BUILT NOTES TO CAD N/A N/A r:, r 4 BUBBLE NOTES: ALL THE CLOUD AREA ARE THE ADDITIONAL SCOPE OF WORK. O Without Comments As Noted in Red G Per The Attached Letter -ase plans have been reviewed by The Tukwila Fire 'ention Bureau for :-nformance with current City ndards. Accep,= -,_ suriject to errors and - •- ijsslons wiltr1177777. _•-!•i,r)--•:)rize violations of adopted -- 'dards and ordi anc-: :-ne responsibility for the Guacy of des 3 ..._ .. r._,taiiy the designer. ditions, -evisions to these drawings after anis date will vc ci �i=: c:eptance =.nd will require a resubmIttai o; revised•i.yinos .c_r subsequent approval. Final acceptance StitsijtaCt ri-=-l. re;t and inspection by The Tukwila Fire Preventi;( Eh,eau. Date: /;-) --1 r'1 By: C acceptance ., 01. . 0 . Fire Permit Number To 011206- 75-4407 Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 REV. BY: 0 m DESCRIPTION SHOP DRAWINGS DATE 2aaaaa C0 0 T co co W �o O W �z Lifj W W= CL Q = 4 og SCALE: 1/8"=1' DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 1 1 /01 / 19 BACKROUND PLAN PROVIDED BY: .JOB NUMBER: 49194-1} SHEET FA -01 .6E r - Le CH. The: L._ 11 STARBUCKS SEATTLE MARINERS TEAM SHOP Ltj FRANK[...II\1 LL - VERIZON \ALRELESS w __Tr • 1". tf---L-,/ ij. ''•••• ELEC PACIFIC Q,UNpivEAF•;), THE V\ALKING CC). L 1100 H eoe r cti\IG1 AcS I 11'1151 SEPHORA NORTH F S,2V 75 C 75 C 75 [HALLMARK uJ11 :F- T -E RARE ROSE HOT TOPIC BUBBLE NOTES: ALL THE CLOUD AREA ARE THE ADDITIONAL SCOPE OF WORK. CINGULAR ir 0 m0 U) T -MOBILE BIT OF HAWAII !CORDON'S \ifvF- r MRS. FIELDS 11451 ELEC. 1.1 L CLAIRE'S JOURNEYS BASKIN ROBBINS I. MEN (r) 0 0 .115(Sisi Li 1155 SUNGLASS HUT 0 m 0 0 0 SYSTEM CALCULATIONS ENDLESS I 11\1r+OVA I Orii5. • • >_ - J CLI- • 0 T- r-) 0 Gq • CHCCO- LATE AR KITS CAMERA MOTHERHOOD MATER' PIERCING PAGODA LIDS THE CITY LJ ! J.C. GO 0 EL L.4 APPLE FACP ADD ONS DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: 0, ‘5 Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 AD2-P (E)1 0.0635 0.0635 0.064 0.064 HTR-R(N-1) ' - 1 ICP -B6 ---- COlig8bOs' - - -0.-o-obt--- --6.511 0.108 - a 1 . ZH-MC-CW©30CD 1.18 ell 1.11 0.142 0.142 0.005 (E) 2 219 438.000 ZH-MC-CW©110CD (E) 2 259 518.000 0.0731 Amps 0.127 Amps ZR -MC ©15CD Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC ©30CD 0.098 HCP Alarm Current Load: 0.127 Amps For 5 Minutes= 0.011 Amp -hours 0.03 Amps 956.84 Amps 25% Derating= 2.206 Amp -hours 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 956.84 Total System Current Load: For 5 Minutes= 2.206 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Amp -hours APPLE SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: 0, ‘5 Device Type Qty Amps Total Amps Total Main System Board (E) 1 0.03 0.03 0.030 0.030 ZH-MC-CW©15CD (E) 5 0.108 0.540 ZH-MC-CW©30CD (E) 1 0.142 0.142 ZH-MC-CW@75CD (E) 2 219 438.000 ZH-MC-CW©110CD (E) 2 259 518.000 ZR -MC ©15CD (E) 2 0.064 0.128 ZR -MC ©30CD 0.098 HCP 0.0015 0.03 Amps 956.84 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 956.84 Amps For 5 Minutes= 80.375 Amp -hours 25% Derating= 101.368 Amp -hours Total System Current Load: 101.368 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION h fl 1 0'JO r APPLE WESTFIELD SOUTHCENTER MALL SCALE 1132 2S,2V 2S,2V 2S,2V 2S,2V OL El 75 C 15 C -1:0L-S1 D 0 A BOX1 EX FACP - - - , 1 Notification Appliance Circuit Detail ! PROJECT: I WESTFIELD SOUTHCENTER MALL , . ,----------------- -------:------------- - i Panel APPLElSI , iWire Resistance 1.62 ' ! * i Date: I September 9, 2008 CURRENT TOTAL= i 793 , i ciRcumlsi QTY Device Type ;AlC arm urrent i AlTotal VVi arm re Size VVire Length Voltage at EOL ' CircuitTotal !1 (E) 4 iZH-MC ©15CD , 108i 432 Total Wire Resistance ( R i ) -" ii 0.451, , 1 „•_.._ , . _............___. ,.„ __ .. ..., i(E) 1421- 1 1 1ZH-MC @75CD 2191 219 ' Total Device Load, Amps (1) ! 0.791 0 I , i I 0 (Total Cct Load) 0 0 Voltage Drop ( E) 0.351 1 0 1 I 0 , EOL Voltage O , , 0 (20.4 - E) 0 1 (E= I * R) 0 lz-mc@15co 641 0' 0 ;Z-MC©30CD 981 01 DEVICES=16 TOTAL m A= I 793 12 138 20.04543384 Notification Appliance Circuit Detail 1 PROJECT: WESTFIELD SOUTHCENTER MALL 793 Panel: APPLE S2 Wire Resistance 1.62 - - - Date: Octoberl, 2008 CURRENT TOTAL= 754 CIRCUIT:1S1 QTY 1 ,ZH-MC ©15CD 0 ZH-MC ©30CD 2 ZH-MC ©110CD Device Type 0 0 0 0 • 0 2 0 Z-MC@15CD Z-MC©30CD DEVICES=I5 20.051 ,Alarm Current! Alarm Total Wire Size 1 Wire Length ! Voltage at EOL 1 CircuitTotal 1 1081 1081 1 1 !Total Wire Resistance ( R ) 1.61 1421 0 1 (WL*2)*(R/ft) , 2591 ' 518 , i Total Device Load, Amps (I) 0.75 0 (Total Cct Load) 0 IVoltage Drop ( E ) 1.21: 0 (E= I* R) 0 EOL Voltage 19.191 0' 1 (20.4 - E) 64! 128 981 0 TOTAL m A=1 754 12 497 19.18584888 754 RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m w DESCRIPTION SHOP DRAWINGS DATE 0, ‘5 2 <<<<< CC cr w z 0 z 0 -J 0 w (1) 'CALE: 1/8"=l' DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE:11/01/19 BACKROUND PLAN PROVIDED BY: .,JOB NUMBER:49194-1} SHEET FA -02 L 2IS F IF 15 C S1-211ODV S2 -18.96V FAC =J . / J 2S J NORTH ►'r► -c c4' T. U. e 5vtSS APPLE WESTFIELD SOUTHCENTER ALL SCALE 118':V FT,AG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATION SUBMITTAL FOR L❑CATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR. SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM, FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. FIELD VERIFY EXACT L❑CATION FOR HTRI—R TO RELEASE MAG LOCK (WITH OWNER SECURITY CONTRACTOR). BUBBLE NOTES: 0 Q ALL THE CLOUD AREA ARE THE ADDITIONAL SCOPE OF WORK. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved co 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m m DESCRIPTION SHOP DRAWINGS DATE 0, 0 2aaaaa 1� 1 Z CC 0 0 J O co co W CC J( O Wz 2 zz W I cc U O) < :D 0 1 w W EC T. l\ i 6ALE: 1/8"=1' DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 1 1 /01 /19 BACKROUND PLAN PROVIDED BY: JOB NUMBER:49194-1} 1 SHEET FA -03 • APPLE FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM I\FORMATIO\ FA -02 TYPICAL DETAILS - WRING AND MOU\TI(N G FA -03 FRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISE, SITE PLAN T Without Comment* As Noted In Red Per The Attached Letter 1 nese plans have been reviewed by The Tukwila Fire Prevention Bureau for confoi rnance with current city standards. Acceptance is »t.thi t to errors and omissions which do not autrtorize violations of adopted .stanaaras and orainances. The r•_: ponsibituy for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this acceptance Rnd will require a resubmittal of revised drawings, for subsequent approval. ,Final acceptance is subject to field test and inspection b‘ The Tukwila Fire Prevention Bureau. / Date: r'4 - (7 - OB By: f TUKWILA FIRE DEPARTME Pease call: 575.4407 and give this job No. -F-L151 :,cap' a,Lidress for shut. %.,ynn or r-ast:;ration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to thi✓ .inspector prior to coiomencFltient of Acceptance Tes',.:Tic4 of any Fire Alarm and Detection Systems. Failure of test wilt result in a Re -inspection Fee a! termination of the WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO#16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER 'IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 1 2 7 2 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD I o I� LINEAR BEAM I N SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD A SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT SMOKE p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING Ir IC FIRE ALARM SPEAKER STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM STROBE (CEILING MOUNT) ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING 4 C FIRE ALARM STROBE (WALL MOUNT) FIRE ALARM SPEAKER (CEILING MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM BIS STROBE WP (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.D. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.D.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I IAN DESCRIPTION SHOP DRAWINGS DATE 0 0 rn 2 CaCC( co co J c0 (1) Z W cc© W J zz rit Lim rig=Q iftC Q CC c,) CD CD co CALE: 1 /8"=1 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: .1OB NUMBER: SHEET i FA -01 J THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT IAB. SSE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL END DF LINE DEVICE(3,6K 1/4W) SUPERVISED SWITCH h v - O DUCT DETECTOR L❑CATION 1 GROUND 0 M 0 -0 10 © HTRI-R OSTATUS LED m N.0 r 0 COM (D 0 N.C. ( NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL O LABEL SCALE PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE (BACKGOUND MUSIC SHUTDOWN) + NOTE 1; VOLTAGE MAX. - CURRENT MAK- CONT. RES. MAX.- MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - OUTLET SAMPLING TUBE INLET SAMPLING—\ TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE j(+) STOP IF LAST DEVICE l(-) FROM XLS CONTROL PANEL OR {(+) PREVIOUS ADDRESSABLE DEVICE (-) END OF LINE DEVICE (3.6K 1/4V) RELAY CONTACTS (4.0A C_-125VAC) (4.0A @ 3OVDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 21 ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST 25 SEC. TO GUARANTEE DETECTION. 0 + 1001 TB1 ssoeea 123456 HCP TB2 0 0 65"43 21 O 1 A 0 � SUPERVISED._)f % SWITCH i GROUND / 0 © © HTRI-D OSTATUS LED 0 NOT USED CO 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL `"BE` SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC 1.1 Im U 0 0 PAD -3 0 00 O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - Tei 24K n + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE 0 END OF LINE DEVICE 3.6K 1/4W) NAC -4 NAC -3 NAC -2 NAC -1 UPERVISED WITCH NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE .r... DEVICE LOOP 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS �W► EOL • 0 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCAT NONE (+ FROM FACP ( 0 0 EARTH GROUND --)..(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE HORN STROBE I STROBE MIRING DIAGRAM LABEL SCALE SPEAKER STROBE OR STROBE ONLY R 0 O 0 HORN/STROBE 4S DEEP BOX I w/ 1-1/2" EXTENSION RING j(SPEAKER STROBE) 4S BOX (STROBE ONLY) WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE EEL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERrN TEMPERATURE: +32' F 0- C TO 100' F (35 C) HUMIDITY: 9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS USTED FOR AIR YOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR r DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL SEL SCALE ( ) DATA OUT > (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTI❑N BOX MOUNTED ON CEILING. FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT / / / / / 0 0 0 IL TO NEXT DEVICE —CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE co 0 co 0 rn J 1 �CALE: 1 /8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 9/08/08 BACKROUND PLAN PROVIDED BY: \OB NUMBER: (e SHEET FA -02 J 2S F S1=213:0-5VA—BOX FACP S2 -18.96V EXI j D 2S 7 2S i' LAG I\OTES: NORTH 26'-6" iio � ttc7 APPLE V ESTFIELD SOUTHCENTER MAIL StA SCALE 118"=1 2S 110 26'-6 lyr 11� L. FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACT❑R, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I z DESCRIPTION SHOP DRAWINGS DATE 9/08/08 oa\a\a CALE: 1/8" =1 ' 1 DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: �OB NUMBER: SHEET FA -03} 0U-) Cfsi 0 0 N J Q W _ 0 Le CHATEL STARBUCKS SEATTLE MARINERS TRAM SHOP u 0 w 0 w VERIZON 1, Wi ELESS (f FOOTACTIC ACTIO HALLMARK (n /H. €uTI VA TF �- LLULA,R THE RARE ROSE THE LOCKER ROOM U 0 0 0 CINCUL AR 0 U (f) 0x z0 <m 0 U_ z (1) I, i11 1 ii >- =z < U-� T -MOBILE k,BIT OF 1, HAWAII J J 0 ID m fy !GORDON'S zl JEWELERS 0 1 T 0 MRS. FIELDS CTRASJ ELEC i PACIFIC SUNWEAR WEAR Nim a l 04k I g MOM OMNI MOM r iiiirii ii iii Via mom a n iuP CLAIRE'S JOURNEYS BASKIN ROBBINS THE 'r4ALKIIsiG CO. 1100 bebe 11101 SUNGLASS HUT 11 1115 SEPH0RA I 1 ^')n SWAROVSKI NORTH PINK BANANA REPUBLIC SKETCHERS 114011 APPLE WESTFIELD SOUTHCENTER MAGI > ry 0 1145 s Cr) 0 0 z 1 1155 ? 1�_ z 0 0 SUNGLASS HUT r -i LJ r� LJ I- -1 LJ r� LJ ry < Ld w (I) m 0 0 L,J J f--- 0 (I)0 ID J 1 0 BOMBAY CO. ENDLE I NIO\/A KITS CAMERA >-0 0 0 0= MU) MOTHERHOOD f` ATERN PIERCING PAGODA LIDS SPECS IN C f,i1\NK THE CITY LJ Cf TRASH CHAMPS SPORTS Y SYSTEM CALCULATIONS w O BATTERY SIZING CALCULATION m 0 J 1006 SCALE 1132 2S 2S 2S 2S 1:, 110 110 15 15 15 2S 2S 2S 2S 2S 2S 15 15 75 15 C 15 C 30 EOL -S1 EX EOL -S2 n,ID 2I APPLE APPLE FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations PROJECT: WESTFIELD SOUTHCENTER MALL Panel: =APPLE S1 ;Wire Resistance 1.62 Date: ;September 9, 2008 i CURRENT TOTAL= 793 « Current Load: CIRCUIT: S1 Standby: Alarm: Current Load: _ _ Standby: Type }__...__.._._.•._._._-_-_-_-_---._._ Alarm: Alarm Total 1 Wire Size Wire Length Voltage at EOL Circuit Total 4 15CD C 1ZH-M _-_---� 108. 432, I Total Wire Resistance (R) 1 0.45 1 1ZH-MC @30CD I 142 Device Type 1 Qty Amps Total Amps Total 1ZH-MC @75CD Device Type 219` Qty Amps Total Amps Total HFP-11 0 0.0022 0.0022 0.0023 01 [ Voltage Drop ( E) ; 0.35 0 AD2-P 1 0.0635 0.0635 0.064 0.064 0__ Main System Board 1 1 0.03 EOL Voltage 1 0.03 0.030 0.030 0 HTR -R 2 0.009600 0.0096 0.021 0.042 ZH-MC-CW @15CD - 5 0 Z-MC@30CD 98 0' r 0.108 0.540 HTRI-D i -_.----xzz::i __ - _mA= 0.001600 0.0035 DEVICES=,6 TOTAL 7931 12 138 1 20.04543384 ZH-MC-CW @30CD 1 0.142 0.142 ICP -B6 Notification Appliance Circuit Detail 0.005 1 PROJECT: WESTFIELD SOUTHCENTER MALL ZH-MC-CW@75CD 2 APPLE S2 ;Wire Resistance 1.62 219 438.000 CURRENT TOTAL= 754 CIRCUIT: S1 ZH-MC-CW @110CD 2 QTY Device Type 259 518.000 Wire Length 1 Voltage at EOL Circuit Total - 1 ZH-MC @15CD 108 1081 1 Total Wire Resistance (R ) -� 1.61 0 ZH-MC @30CD _ 142 0 ( 2 ZH-MC @110CD 259 5181 Total Device Load, Amps (I) i 0.75 001 � _ ____ _ �� ___ 0.0731 Amps 0.106 Amps 0 01 Voltage Drop (E) 1 1.21 ZR -MC @15CD I 2 0.064 0.128 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 2 Z-MC@15CD 0.098 1281 0 Z-MC@30CD 98 0k 1 HCP 1 r 1 1i f 0.0015 Alarm Current Load: TOTAL mA= 0.106 Amps For 5 Minutes= 0.009 Amp -hours --- 0.03 Amps 956.84 Amps _ 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 956.84 Amps For 5 Minutes= 80.375 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 101.368 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 101.368 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION m 0 J 1006 SCALE 1132 2S 2S 2S 2S 1:, 110 110 15 15 15 2S 2S 2S 2S 2S 2S 15 15 75 15 C 15 C 30 EOL -S1 EX EOL -S2 n,ID 2I 1743 FAX (206) 628-4990 TEL. (206) 622-65/45 RELEASE/REVISIONS REV. BY: I z a Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: =APPLE S1 ;Wire Resistance 1.62 Date: ;September 9, 2008 i CURRENT TOTAL= 793 « CIRCUIT: S1 _ _ QTYDevice --•_._-._- _._.__ ..__ Type }__...__.._._.•._._._-_-_-_-_---._._ Alarm Current Alarm Total 1 Wire Size Wire Length Voltage at EOL Circuit Total 4 15CD C 1ZH-M _-_---� 108. 432, I Total Wire Resistance (R) 1 0.45 1 1ZH-MC @30CD I 142 142' 1 (WL * 2 )* (R/ft) 1 1 1ZH-MC @75CD i 219 219` Total Device Load, Amps (I) 1 0.79 i 0 (Total Cct Load) 01 [ Voltage Drop ( E) ; 0.35 0 0 0__ 1 0 1 EOL Voltage 1 20.05 0 0 (20.4 - E) 0 1Z -MC _Y.@15CD 64 0 _�_.._.___.._-_.--- , - 0 Z-MC@30CD 98 0' r i -_.----xzz::i __ - _mA= DEVICES=,6 TOTAL 7931 12 138 1 20.04543384 793 Notification Appliance Circuit Detail 1 PROJECT: WESTFIELD SOUTHCENTER MALL Panel: APPLE S2 ;Wire Resistance 1.62 Date: October 1, 2008 CURRENT TOTAL= 754 CIRCUIT: S1 ____--_____; ____________- QTY Device Type Alarm Current Alarm Total 1 Wire Size Wire Length 1 Voltage at EOL Circuit Total - 1 ZH-MC @15CD 108 1081 1 Total Wire Resistance (R ) -� 1.61 0 ZH-MC @30CD _ 142 0 ( 2 ZH-MC @110CD 259 5181 Total Device Load, Amps (I) i 0.75 001 � _ ____ _ �� ___ s (Total Cct Load) 0 01 Voltage Drop (E) 1 1.21 I EOL Voltage - 19.19 001 (20.4-E) 2 Z-MC@15CD 64 1281 0 Z-MC@30CD 98 0k 1 1 r 1 1i f . DEVICES=5 TOTAL mA= 7541 12 497 19.18584888. 754 - i 1743 FAX (206) 628-4990 TEL. (206) 622-65/45 RELEASE/REVISIONS REV. BY: I z a DESCRIPTION SHOP DRAWINGS DATE CO 0 co 0 rn I « 0 w c w C1) w cC rr w z LU z d P - w C/) cn 6ALE: 1/8" =1 ' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 9/08/08 BACKROUND PLAN PROVIDED BY: �OB NUMBER: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -04 UiS0h FILE COSY APPLE FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WRI\G AND MOUNTING FA -03 FIRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIO\S (GENERAL), RISE, SITE PLAN TUKWILA FIRE -DEPARTMENT. Please call: 575-440Z and give this job and exact address for shut, bun or restoration approval, WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDIO TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 1 2 7 2 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD ISN LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE ®D DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE F C (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM STROBE (CEILING MOUNT) ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM © STROBE (WALL MOUNT) FIRE ALARM SPEAKER (CEILING MOUNT) Q C ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.0.N. SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING r-oWP FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD ❑M MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.D.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z 4 DESCRIPTION SHOP DRAWINGS DATE co 0 co 0 rn 2CCCCC 1 0 co 2 co J '- J C° <0.) CCW , .O w 63 W~ 1/45 0 J Zz 0- cc IL Q_gI< < < F3- Z CC OJ o c0 = I2- W } N CALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 9/08/08 BACKROUND PLAN PROVIDED BY: SOB NUMBER: SHEET k FA -01 J THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL Sri COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC 0 DUCT DETECTOR LOCATION END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH 1. 1 0 CN r7 m GROUND Lc) HTRI-R OSTATUS LED Co 0 N.O. r -- 0 1 N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL 0 `L SCALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLEC DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX. - CURRENT MAK-- CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - OUTLET SAMPLING TUBE INLET SAMPLING—� TUBE \ AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE f (.F) STOP IF LAST DEVICE l(-) FROM XLS CONTROL PANEL OR �(+) PREVI❑US ADDRESSABLE DEVICE (-) RELAY CONTACTS (4.0A @ 125VAC) (4.OA @ 30VDC) 27 VDC 3.5 mA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. + 10 01 TB1 56009 123456 HCP TB2 0 0 65 4321 O 0 END OF LINE 1 DEVICE �T SUPERVISETI SWITCH % GROUND (3.6K 1/4W) 0 0 0 10 HTRI-D OSTATUS LED 0 NOT USED CO 0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL " L scAl (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC in ta I T 0T El 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - $ o] Co *ll 24K TYPICAL V\1IRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE 2 NAC -4 NAC -3 ?NAC -2 ?NAC -1 END OF LINE DEVICE 3.6K 1/4W) SUPERVISED SWITCH FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0- 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS EOL 0 O (NPU (+ TM -1 Q • 0 0 -1-2-3 4 5 e TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL 0 0 EARTH GROUND .-)(+)TO NEXT DEVICE OR >.(-) STOP IF LAST DEVICE HORN STROBE 1 STROBE WIRING DIAGRAM LABEL SCALE SPEAKER STROBE OR STROBE ONLY R E 0 ! 45 DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) HORN/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE E❑L NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER11N TEMPERATU� E: +32' F (0' C) TO 100" F (338' C) HUMIDITY: O-933333% RELATIVE HUMIDITY, NON -CONDENSING HEP -11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOaTY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION 'NTH DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 J STANDARD / SMOKE DETECTOR BASE HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID —\ CEILING / SPEAKER SUPPORT TILE BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTI❑N BOX--\ MOUNTED ON \ CEILING, FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT / / / / / / / O O O O 1 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE \--SUSPENDED ILLUMINATED CEILING DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z Q DESCRIPTION SHOP DRAWINGS DATE co 0 co 0 rn 2 CCCCC z z 0 z z (/1 —J 7Itt. 0 J CALE:1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: `JOB NUMBER: SHEET J FA -02,, 1 1 1 LNL 5 D,I 2I 15 S1 -20.05V S2 -18.96V FACP rLac NOTS: 26'-6" 110 1i NORTH 2S VL_ 110 26'-6" APPLE WESTFIELD SOUTHCENTER MALL SCALE 118"=1' FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATION SUBMITTAL FOR L❑CATI❑N GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACT❑R, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLATOR FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE P❑WER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE co 0 03 0 rn 2 aC\\a 6ALE: 1/8"=1' u. DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: ,JOB NUMBER: SHEET FA -03 STARBUCKS SEATTLE MARINERS TEAM SHOP J FO0TA0TI0N MARK'S HALLMARK THE LOCKER ROOM VRaZON ATIVATER THE RARE ROSE WIRELESS C LLULA FRANKLIN COVEY w TRASHI 9 ELEC r 0 L� J -)Et4 PACIFIC SUNWEAR ABERCROMBIE & FITCH THE \ALKING CO. [1100 bebe 1110 SUNGLASS HUT 111151 SEPHORA SWAROVSKI NORTH PINK HOT TOPIC CINGULAR BANANA REPUBLIC BROOKSTONE LL 0 a O a 0 Qw N_ GADZOOKS Ct 1.L1 1.1J U z <0 Q 0 -_JJ W 0 5 BIT OF HAWAII GORDON'S JEWELERS SKETCHERS 111401 APPLE WESTFIELD SOUTHCENTER MALL N w w cc 0 LL 1145 MRS. FIELDS CLAIRE'S JOURNEYS BASKIN ROBBINS MEN ZALES JEWELER SUNGLASS HUT 1--I LJ r-, LJ ri LJ r-1 LJ CHOCO- LATE 0 0 laJ __J 0 O 0 BOMBAY CO. ENDLE INNUUVA KITS CAMERA >-cL 00 o= COM MOTHERHOOD MATERN11 PIERCING PAGODA LIDS J �n 0 z w 1--- 1155 SPECS IN THE CITY p CHAMPS SPORTS Y SYSTEM CALCULATIONS z W BATTERY SIZING CALCULATION 0------', 'S I , X J ' \ - ' - -- -,--3-5.r----- - - LOVE CULTURE 1006 SCALE 1132 2S 2S 2S 2S 110 2S 110 2S a va 15 2S 15 2S F 15 2S 15 15 75 15 C 15 C 30 0 EOL -S1 2S 2S FA -BOX EX FACP 0 EOL -S2 D,ID 2I APPLE APPLE 1.62 793 FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations - PROJECT: WESTFIELD SOUTHCENTER Panel: APPLE Si !Wire Resistance October 1, 2008 CURRENT TOTAL= Date: September 9, 2008 CURRENT TOTAL= Current Load: S1 Standby: s Alarm: Alarm Current Current Load: Wire Length 1 Voltage at EOL Circuit Total _i y Standby: Alarm: Device Type Alarm Current Alarm Total 1 Wire Size Wire Length Voltage at EOL Circuit Total 0 142 259 4 ZH-MC ©15CD 108 4321 142 (WL* 2 ) * (R/ft) - � �__ -_ _ Total Device Load, Amps (I) I 0.75 2 1 Device Type s 01 Qty Amps Total Amps Total 1 Device Type 219 Qty Amps Total Amps Total HFP-11 !-^ 0.79 0.0022 0.0022 0.0023 0; 0 0 04 0 _ (20.4 - E) Voltage Drop (E )'� _____�___0.350 AD2-P 64 1 0.0635 0.0635 0.064 0.064 0 Main System Board 98 1 0.03 0.03 0.030 0.030 HTR -R DEVICES= 2 0.009600 0.0096 0.021 0.042 ZH-MC-CW @15CD 5 0.108 0.540 0 HTRI-D 64 0;J 0.001600 0.0035 ZH-MC-CW @30CD - 1 Z-MC@30CD 98 01 0.142 0.142 ICP -B6 0.005 ZH-MC-CW @75CD 2 DEVICES= 219 438.000 793! 12 138 20.04543384 793 _ ZH-MC-CW @110CD 2 259 518.000 0.0731 Amps 0.106 Amps ZR -MC @ 15C D 2 0.064 0.128 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours _ZR -MC @30CD 0.098 HCP 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.03 Amps 956.84 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 956.84 Amps For 5 Minutes= 80.375 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 101.368 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 101.368 Amp -hours I Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION 0------', 'S I , X J ' \ - ' - -- -,--3-5.r----- - - LOVE CULTURE 1006 SCALE 1132 2S 2S 2S 2S 110 2S 110 2S a va 15 2S 15 2S F 15 2S 15 15 75 15 C 15 C 30 0 EOL -S1 2S 2S FA -BOX EX FACP 0 EOL -S2 D,ID 2I 1743 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 w w w J W REV. BY: Notification Appliance 1 Notification Appliance Circuit Detail MALL 1 J 1.62 793 1 - PROJECT: WESTFIELD SOUTHCENTER Panel: APPLE Si !Wire Resistance October 1, 2008 CURRENT TOTAL= Date: September 9, 2008 CURRENT TOTAL= CIRCUIT: S1 QTY Device Type Alarm Current Alarm Total 1 Wire Size Wire Length 1 Voltage at EOL Circuit Total _i y �� QTY Device Type Alarm Current Alarm Total 1 Wire Size Wire Length Voltage at EOL Circuit Total 0 142 259 4 ZH-MC ©15CD 108 4321 142 (WL* 2 ) * (R/ft) - � �__ -_ _ Total Device Load, Amps (I) I 0.75 2 1 s 01 Total Wire Resistance (R) 0.45_ 1 ZH-MC @30CD 142 1 ZH-MC ©75CD 219 2194Total Voltage Drop (E) I 1.21 (E= I* R) 0 Device Load, Amps (I) (Total Cct_Load) !-^ 0.79 o 1 0; 0 0 04 0 _ (20.4 - E) Voltage Drop (E )'� _____�___0.350 Z-MC@15CD 64 128 -{ 0 Z-MC@30CD 98 _ 01 DEVICES= 5 EOL Voltage 20.05 o 754 0 (20.4 - E) i 1 0 Z-MC©15CD 64 0;J 1 - 0 Z-MC@30CD 98 01 DEVICES= 6 TOTAL mA= 793! 12 138 20.04543384 793 _ 1743 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 w w w J W REV. BY: Notification Appliance Circuit Detail I 4 4 1.62 754 I PROJECT: WESTFIELD SOUTHCENTER MALL Panel: APPLE S2 (Wire Resistance DATE Date: October 1, 2008 CURRENT TOTAL= CIRCUIT: S1 QTY Device Type Alarm Current Alarm Total 1 Wire Size Wire Length 1 Voltage at EOL Circuit Total �� 1 ZH-MC @15CD 108 108 Total Wire Resistance (R) J T 1.61 0 ZH-MC ©30CD ZH-MC 11OCD @ 142 259 01 518' 1 ; (WL* 2 ) * (R/ft) - � �__ -_ _ Total Device Load, Amps (I) I 0.75 2 0 s 01 1 (Total Cct Load) 0 0i 01 Voltage Drop (E) I 1.21 (E= I* R) 0 0 _ 01 1 EOL Voltage t 19.19 0 0 _ (20.4 - E) 2 Z-MC@15CD 64 128 -{ 0 Z-MC@30CD 98 01 I DEVICES= 5 TOTAL mA= 7541 2 497 19.18584888 754 1 1 , 1743 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 w w w J W REV. BY: z 4 DESCRIPTION SHOP DRAWINGS DATE co 0 c0 0 rn z <CCCC 0 w D C/) co EE co T �� J w � 0 CC � W cc CL w= W ize CD Q 1'S ITEs 1- 0 W t� V J �CALE: 1/8"=1 ' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 9/08/08 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ..JOB NUMBER: SHEET i FA -04 } FiLE COPY APPLE FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET NUM3ER SHEET TITLE SHEET INDEX FA -01 SYSTEIV INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISE, SITE PLAN 1 !nese plans have been reviewed by The Tukwila Fire Prevention Bureau for cor:ioi -n.,with current city L, standards. Acceptance is tc :,refs and E omissions wl-r ch do not aticns of adopted st'fl k.f,:!,. :., fbUi for the Addriticr:5, C'_.. :i t:. oi , :/::;i_.._ 6rav,ings atter this da_2 c u it =cc ;:�::;:;.,. .nCi wili require a resubmittal of revised'Lir a:':'(('ig far subsequent approval. Final acceptance is subject to field test and inspection b\ 1The Tukwila Fire Prevention Bureau. Date: /'��'7b By: �� I n Without Comments As Noted In Red Per The Attached Letter f UKWILA FIRE DEPARTM9EM. Please call: 575-4407 and give this job No. ON -F - LIS and exact address for shut' Iiu vn or restoration aooraval. 1 ri 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. 1 may"TfANT Buse of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you n ed to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inF 'tion. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIAT❑R TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART' NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NEPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED SYMBOLS LEGEND QUANTITY 2 1 6 4 2 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP ® INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD ID a LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP IN/ 1G RING CEILING ® DUCT SMOKE p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE MC (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM SPEAKER STROBE r (WALL MOUNT) FIRE ALARM STROBE C (CEILING MOUNT) ILI ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM STROBE (WALL MOUNT) FSIPEAARE LARM ST C (CEILING MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM B p STROBE WP (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD EU MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.❑. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAID 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NVI DESCRIPTION SHOP DRAWINGS DATE 9/08/08 2CCCCC 1 w Z 0 0 z SCALE: 1 /8”•=1' DRAWN BY: (.ANDERSON ESIGNED BY: .VEZZANI SEP 23 2Q0ly Tukwila Fire a,a7�..JOB NUMBER: Jf/57/ - SHEET FA -01 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved DATE:9/08/08 BACKROUND PLAN PROVIDED BY: THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR if PREVIOUS ADDRESSABLE DEVIL NW - 0 DUCT DETECTOR L❑CATION 1 0 END OF LINE DEVICE(3.6K 1/4W) 0T b 0 SUPERVISED SWITCH GROUND N) Lr) © HTRI—R STATUS LED 0 N.O. r -- (r) c,0 0 N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL O (ABELSCALE(BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX,— CURRENT MAX.— CONT. RES. MAX.— MAX. CABLE LENGTH— C (LINE TO LINE)— C <LINE TO SHIELD)— MAX. LINE SIZE— MIN. LINE SIZE— OUTLET SAMPLING TUBE INLET SAMPLING----\ TUBE \ AT LEAST SIX DUCT WIDTHS FROM BEND 2 TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE f STOP IF LAST DEVICE 1(+) FROM XLS CONTROL PANEL DR PREVI❑US ADDRESSABLE DEVICE (-) END OF LINE DEVICE RELAY CONTACTS (4.OA @ 125VAC) <4.0A @ 30VDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. <18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. 7/ 0 J TB1 123456 HCP TB2 0 O 0 (3.6K 1/4W) i SUPERVISED SWITCH GROUND 0 r7 L(7 © HTRI—D OSTATUS LED r-- CO \ NOT USED (0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABELSCALE(FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC m Wed t7) TY r II 0 0 PAD -3 0 0 00 O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - glial -Q-1 u§11<aa Q. 24K n 1112 + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END DF LINE DEVICE 3,6K 1/4W) `-6UPERVISED WITCH NAC -4 NAC -3 NAC -2 ?NAC -1 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0- 0 0 {FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS EOL TSM —1 O >Ea zoo U Q J °,Ugco QSQ c QOO o • • • TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE 0 0 EARTH GROUND -).(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE HORN STROBE I STROBE WIRING DIAGRAM LABEL SCALE SPEAKER STROBE OR STROBE ONLY R 0 HORN/STROBE 1 4S DEEP BOX w/ 1-1/2" I EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE EDL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER�T1IN TEMPERA RE: +32' F (0' C) TO 100' F (38 C) HUMIDITY: 0-9333333% RELATIVE HUMIDITY, NON—CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT IN WHEN USED IN CONJUNCTION W1111 DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 STANDARD SMOKE DETECTOR BASE FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (—) >- DATA IN (+) > HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL sca1F CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID —\ CEILING SPEAKER SUPPORT TILE BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT JUNCTION BOX \ MOUNTED ON CEILING FLEX SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE io / / / / 0 0 i n TO NEXT DEVICE 0 CADDY BAR \— SUSPENDED ILLUMINATED CEILING DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved CO 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I z d DESCRIPTION SHOP DRAWINGS I DATE 00 0 CO 0 rn 1/ 1 z z 0 0 z 0 z E 0) W �CALE: 1 /8"=1 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 1 r SHEET FA -02} LAG OTES: 51-20 05V S2 -18.96V pLi 30 Il FA—BOX Rl b "VISI D 15 D,I 2I FACP 1 2S c - 2S 2S PI --'15 I 1 .(2,- 2S 2S F 75 y 13 2S- 2S 75 ©C 7513 NORTH APPLE WESTFIELD SOUTHCENTER MALL SCALE 118"=1' FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATI❑N SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z d DESCRIPTION SHOP DRAWINGS DATE 00 0 co 0 0, 2Ca\\C / W uJ u. �CALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: _JOB NUMBER: i SHEET FA -03 J )) IL- \--4 WIZON WINELESS 1 0 LLI Z 0 0 -j- LJ n Le CHATEL ijij STARBUCKS SEATTLE MARINERS TEAM SHOP PACIFIC SUNWEAR ACTIVAL_F CILLLULAK RAVE GIRL THE WALKING CO. 1100 bebe SUNGLASS HUT SEPHORA 111151 I .1 1 r\ SWAROVSKI NORTH PI\IK Ji FOOTACTION USA THE RARE ROSE LL m bi m LJJbi u.) LLi< 0 _J J LOCKER ROOM HOT TOPIC (f) oc ZLd aT (f) < - LL! C INC U L AR Kfl I I -L Z I < (l) • • • • • T -MOBILE BIT OF HA\/AII enRDON'S JEWELERS M R S. FIELDS BASKIN ROBBINS _J CO 0 0._ w ft cn SKETCHERS APPLE WESTFIELD SOUTHCENTER MALL 1145 (7)9 sUNGLASS HUT F- -1 LJ I- -1 LI I- -I LJ L (1) 0 0 p 0 (f) 0 BOMBAY CO. ENDLE IN NOVA K I TS CAMERA C MOTHERHOOD MATERN PIERCING PAGODA LDS i SPECS IN l4iNt\i THE CITY L J I TRASH J. C . SYSTEM CALCULATIONS CHAMPS SPORTS 1 0 I 2 BATTERY SIZING CALCULATION 1 g\ 11150 LI1155 X Or--- -- I . . \ J 1 \ 1 _ LOVE CULTURE 10061 SCALE 1132 2S 2S 75 C 75 C 75 2S 2S 15 15 75 F 2S C 15 2S 15 2S 15 2S C 15 2S 15 2S C 30 2S Iva EOL -S1 2S FA -BOX EX fl DID 21 Notification Appliance Circuit Detail PROJECT: 'WESTFIELD SOUTHCENTER MALL Panel: APPLE S1 Date: CIRCUIT: QTY 4 iWire Resistance 1.62- i September 9, 2008 1 _ ! Device Type 'Alarm Current Alarm Total 1 Wire Size ZH-MC ©15CD . . 108 4321 1 IZH-MC ©30CD CURRENT TOTAL= 793 Wire Length Voltage at EOL Circuit Total 142 ©75CD ZH-MC 1 1 219 , 0 0 0 i 0 0 0 1421 2191 0 01 Total Wire Resistance ( R ) (WL*2 )*(R/ft) 0.45 Total Device Load, Amps (I) (Total Cct Load) 0.79 Voltage Drop ( E) 0.35 01 01 o o I Z-MC@15CD 64 0 IZ-MC©30CD 98 (E= I * R) EOL Voltage (20.4 - E) 20.05 ol DEV10ES=16 TOTALmA= 7931 12 138 20.04543384 793 APPLE APPLE Notification Appliance Circuit Detail FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS _ PROJECT: __ ___ WESTFIELD SOUTHCENTER Panel: APPLE SI MALL i 1.62 893 oo 0 co 0 .,. 0, 2 Wire Resistance <CC< Current Load: Date: September 9, 2008 CURRENT TOTAL= Standby: Alarm: Current Load: CIRCUIT'S1 1,. Standby: Alarm: .....__ CITY Device Type _jAlarm Current 108 Alarm Total 1 108 Wre Size Wire Length 1 Voltage at EOL Circuit Total 1ZH-MC ©15CD 1 1 Device Type Qty Amps Total Amps Total 0 'ZH-MC ©30CD Device Type 0 Qty Amps Total Amps Total HFP-11 219 6571 0.0022 0.0022 0.0023 Total Device Load, Amps (I) 0.89 7 0 0 1 AD2-P (Total Cct Load) 1 0.0635 0.0635 0.064 0.064 01 Main System Board 1 0.03 0.03 0.030 0.030 _._,..., HTR -R 0 2 0.009600 0.0096 0.021 0.042 1 ZH-MC-CW ©15CD ......_._ ,__............. 5 i 1 0.108 0.540 HTRI-D (20.4 - E) 0.001600 1281 0.0035 ZH-MC-CW @30CD 1 0 Z-MC@30CD 98 0 1 0.142 0.142 ICP -B6 0.005 1 ZH-MC-CW ©75CD 4 DEVICES=16 TOTAL m A= 219 876.000 893 0.0731 Amps 0.106 Amps ZR -MC @15CD 2 0.064 0.128 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 0.098 HCP 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.03 Amps 876.84 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 876.84 Amps For 5 Minutes= 73.655 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 92.968 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 92.968 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION 1 g\ 11150 LI1155 X Or--- -- I . . \ J 1 \ 1 _ LOVE CULTURE 10061 SCALE 1132 2S 2S 75 C 75 C 75 2S 2S 15 15 75 F 2S C 15 2S 15 2S 15 2S C 15 2S 15 2S C 30 2S Iva EOL -S1 2S FA -BOX EX fl DID 21 Notification Appliance Circuit Detail PROJECT: 'WESTFIELD SOUTHCENTER MALL Panel: APPLE S1 Date: CIRCUIT: QTY 4 iWire Resistance 1.62- i September 9, 2008 1 _ ! Device Type 'Alarm Current Alarm Total 1 Wire Size ZH-MC ©15CD . . 108 4321 1 IZH-MC ©30CD CURRENT TOTAL= 793 Wire Length Voltage at EOL Circuit Total 142 ©75CD ZH-MC 1 1 219 , 0 0 0 i 0 0 0 1421 2191 0 01 Total Wire Resistance ( R ) (WL*2 )*(R/ft) 0.45 Total Device Load, Amps (I) (Total Cct Load) 0.79 Voltage Drop ( E) 0.35 01 01 o o I Z-MC@15CD 64 0 IZ-MC©30CD 98 (E= I * R) EOL Voltage (20.4 - E) 20.05 ol DEV10ES=16 TOTALmA= 7931 12 138 20.04543384 793 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: . Notification Appliance Circuit Detail DESCRIPTION SHOP DRAWINGS _ PROJECT: __ ___ WESTFIELD SOUTHCENTER Panel: APPLE SI MALL i 1.62 893 oo 0 co 0 .,. 0, 2 Wire Resistance <CC< Date: September 9, 2008 CURRENT TOTAL= CIRCUIT'S1 1,. i , 1 .....__ CITY Device Type _jAlarm Current 108 Alarm Total 1 108 Wre Size Wire Length 1 Voltage at EOL Circuit Total 1ZH-MC ©15CD 1 1 Total Wire Resistance ( R ) 1.61 0 'ZH-MC ©30CD 1 142 0 ( WL * 2 )* (Rift) 3 ZH-MC ©75CD 219 6571 Total Device Load, Amps (I) 0.89 7 0 0 1 (Total Cct Load) 0 : 01 Voltage Drop ( E ) 1.44 0 _ ...,.. _ _ 0 0 2 Z-MC@15CD _._,..., 0 . (E= I * R) 1 ......_._ ,__............. ...._... 0 01 i 1 EOL Voltage 18.96 (20.4 - E) 64 1281 i 1 0 Z-MC@30CD 98 0 1 -7.--- 1 DEVICES=16 TOTAL m A= 8931 1 12 497 18.96201996 893 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS Li.] 1- < cn oo 0 co 0 .,. 0, 2 < <CC< r -Th 0 1.1J F- E) cE C/3 cc (1) 0 cit) (S -ALE: 1/8"=l' DRAWN BY: 'ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ,JOB NUMBER: SHEET FA -04 — I IX 2 EMOVE CAPS AND INSTALL RED COUPLING NOTICE Weld stamps must be inspected before pipe is hung. p_g_Liot paint piping prior to hydrostatic test t'UKWILA FIRE DEPARTME t Please call: 575-440Z and give this job _s_ `'l s Lj Amer' No. 02 and exact address for shuts Town or rsstoration approval, Without Comments As Noted In Red .K Per The Attached Letl+r 1 nese plans have been reviewed by The Tukwila Fire Prevention Bureau for COr;t .rrl,anu�e W;t,T current city standards. Accepterce is , t to ;:.rrcrs and omissions- ; h,'t'ii do not of adopted .. t...:y,w'�^ .�-n: for the .LC:Lh:r i3, It O_ .;_: ola 4rg$atter vi -Fd ii,; . ...., _;r; = n' •:viii require a r e_ubrlittai of revised ara,.i.ings for subsequent approval • Final ecc ptcnce it subject to Feld test and inspection b‘ The Tukwila Fire Prevention Bureau. [Date: 9- /C --O g By: fl a -s . spy-a�vmm..w.R� •+ 3 -3w0 -111k r -r -41-8 EE14' 2-3 O 14p 6 — A-8 LOWER MAIN r- ELEVATION REVISI❑N PER 3rd PARTY REVIEW * HYDRAULICI NODES SHOWN I 35 10'-0' 4 2Y' 5-11 _040, --„,;'- a 2'¢' 0 5-5 �. 1 a' 4� d- 5g, `� 02 + ' 2!�' 5-1 iiiV 1 prL prL I s prL * 1 ' 4 0 1-1.11-4z, L 1, o* 1 �.* :. 0 23? 5-0 •02 1 1 02 o s O'L 1 o`L . .-"/44N 1 02 ;4# s s o2 c lis A —,/ s a 0� v 6 1 prL o 0' ,,.$ 2#. d 8-1 u,ru 1 p2 2#' 4-11 . -'4430' 1 �� 21<Z' 5-7 n' p2 1 i 55. Z 0. 1,P �� 2Y�' 6-1 p,L a 2%' 3-11J a'}}(�{, fl3 -6 I 1 2l¢' �r 6-7 �,L -�� r p2 4 p', 1 3-5• �. •- 1 4- v ' 2 ' � 7-1 p2, 1 I F•}�1�+' 2-tt Si. �h .'t• o i -7 p2 rY 2 . •, . o c -7 1 4 4�21�' x,14 'CSS #� v p� o 16 1 --.-./1.----- .44).1'p9/ 1 117-0' 02 S13 I I 1 r� 0D1 I It,� ' 1 `1 , 02 ,- 1 X02 T 4 S6 s —co x' 02 54 1 , 02 tt 1 , o 0 I — 1 1 1v' p� 1 o'L 11'-0) 1 �, 4 p2 1 �,� � OZ, / 14 1 ®, o`L 1 S9 1 cg, 1 1 & a 4 S12 ¥ 1-)I r _. 1 o'L . o cu 011ft . o 2 C 2' C 2' ~ 8_i ail 6-i (1J M 1' c,) GENERAL NOTES UI NODES AT RISER (SEE CALCULATIONS) '4 OTA T NOTICE Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Tho. fore, you will ne;d to call 205-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. 2. 3, 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. DES,,,WLANDAgS,LALLATION SHALL CONFORM TO NFPA PAMPHLET 13 (2007 ed.) AND ALL 1 CITY OF TUKWILAi REQUIREMENTS. ALL MATERIALS SHALL BE NEW AND U.L. APPROVED. PIPE: ALL PIPE 2' AND SMALLER TO BE SCHEDULE 40 BLACK STEEL. ALL PIPE 2' AND LARGER TO BE SCHEDULE 10 BLACK STEEL. FITTINGS: ALL FITTINGS (SCREWED AND GROOVED) AND GROOVED COUPLINGS TO BE STAR BRAND DUCTILE IRON. PAINTING OF PIPE AND PROTECTION OF SPRINKLER HEADS FROM PAINT IS BY OTHERS. ALL ELECTRICAL WIRING AND C❑NDIUT IS BY OTHERS. ALL WELDING TO CONFORM WITH AWS D10.9 AND WILL BE PERFORMED IN C❑SC❑'S SHOP, IT IS THE BUILDING OWNERS RESPONSIBILITY TO KEEP ALL AREAS WITH WET SPRINKLER SYSTEMS HEATED TO A MINIMUM 40 DEGREES FAHRENHEIT TO PREVENT FREEZING OF PIPES, OWNER IS RESPONSIBLE TO ASSURE THAT STRUCTURE AS IT IS SHOWN ON THE CONTRACT DRAWINGS CAN ADEQUATELY SUPPORT ALL FIRE SPRINKLER PIPING LOADS, NO AUXILLIARY DEVICES OR ATTACHMENTS SHALL BE PROVIDED BY CUSCO TO SUPPLIMENT THE STRUCTURE TO ACCOMODATE FIRE SPRINKLER PIPING LOADS. COSCO ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE DR CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIED OR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY CUSCO FIRE PROTECTION. UNDERGROUND CONTRACTOR SHALL FLUSH THE UNDERGROUND AND PR❑VIDE COSCO WITH THE PROPER CERTIFICATE OF DOING S❑ BEFORE COSCO WILL CONNECT TO THE UNDERGROUND PIPE. SPRINKLER HEADS ARE DESIGNED TO BE IN CENTERLINE OF CEILING TILE (+/— 1'). ALL DIMENSI❑NS ARE TO CENTERLINE OF PIPE. REVISIONS NO. DESCRIPTION DATE BY 0 SUBMITTAL TO TUAZON ENGINEERING -3RD PARTY APPROVAL 09-02-08 T.N.R. SUBMITTAL TO CITY OF TUKWILA 09-09-08 T.N.R. SPRINKLER HEAD LEGEND : SYMBOL SIN 3/8' C -CLAMP WITH 10' RETAINING STRAP HYDRAULIC DESIGN -REMOTE AREA APPLE—MOST REMOTE 1500 ft2 ORDINARY HAZARD GROUP 2 .20 GPM/1500 S.F. K=5.6 130 S.F. MAX. PER HEAD 15 SPRINKLERS IN REMOTE AREA SPRINKLER DEMAND: 650.75 GPM @ 66.402 PSI ADDED HOSE STREAM: 250 GPM TOTAL SYSTEM DEMAND: 900.75 GPM @ 66.402PS ARGCO #3B OFFSET WHERE LENGTH OF ALL THREAD ROD EXCEEDS 1'-10' ADD SECOND RESTRAINT ORIFICE TOLCO FIG. 65 C -CLAMP PIPE ROD SIZE DIA 1” 3/8" 11/4" 3/8" 1 1/2" 3/8" 2" 3/8" 2 1/2" 3/8" 3" 3/8" 4" 3/8" 6" 1/2" 8" 1/2" RETAINER STRAP, NUT THREADED ROD HILTI FIG LH 0R TOLCO FIG 200 HANGER RING UL 04/2007 COSCO STANDARD HANGER #2 I' ALL THREAD ROD TRAPEZE ASSEMBLY 3/8' C -CLAMP WITH 10' RETAINING STRAP 3/8'x6' ALL THREAD ROD 3/8' ALL THREAD ROD WELDED TO END OF PIPE (NTS) SYMBOL = TRPZ EXISTING BRANCHJNE +15-T AFF EE PLAN FOR LENGTH 6'-0"'FLEXHEAD" FLEXIBLE DROP CORRUGATED STAINLESS STEEL BRAIDED HOSE STRECHED MEMBRANE PANEL +11'-0" AFF 4" C -CHANNEL ACOUSTICAL PANEL +l 1'-0" AFF 7 WIDE STAINLESS STEEL CEIUNG TROUGH TYPICAL ARMOVER TO NEW SPRINKLER HEAD (N.T.s.) 3/8 X 3-1/2 LAG SCREW FOR WOOD 3/8' KWIK BOLT FOR CONCRETE . 1/4 X 1 TEK FOR BARJOIST OR STEEL BEAM 3/8'x1-10 ALL THREAD ROD MAX PER SINGLE RESTRAINT HANGER RING (UP TO 2' PIPE) LINE RESTRAINT DETAIL NOTE: 1) SPACE WITH IN 6" OF A HANGER EVERY 42'-0", 2) BRACING PER NFPA-13(2007 ed.) SECTIONS 9.3.5.8.8, TABLE 9.3.5.8,8(c) AND 9.3.6—RESTAINT OF BRANCH LINES NPT K•FACT. HEAD FINISH PLATE FINISH TEMP. QUAN. Victaulic Model V27 SSP on Flex Drop V2707 1/2" 1/2" 5.6 CH CH 155° 47 Reliable Model FT SSU on Sprig -up R1725 1/2" 1/7 5.6 BR N/A 200° 15 APPROVALS BY: CITY OF TUKWILA TOTAL SPRINKLERS THIS SHEET 62 • 000006. • 0 o 0 00. •6 • 4 0 • • • Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS WASHINGTON OFFICE 15000 Woodinville -Redmond Rd NE Woodinville, Washington 98072 call (425) 686-8300 • fax (425) 827-4784 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE • ANCHORAGE www.coscofire.com License No: COSCOFP110NM FILE COPY ATTACH TO BOTTOM OF ROOF DECK WITH TOLCO FIG. 78 THREADED STEEL DECK PLATE (2)-1/4" X I" TEK SHEET METAL SCREW PIPE SIZE I I1/4" 1 1/2" 2" ROD DIA 3/8" 3/8" 3/8" 3/8" THREADED ROD TOLCO FIG 200 HANGER RING 04/2007 COSCO STANDARD HANGER #8 METAL TOLCO FIG. 25 SURGE RESTRAINER TYPE 1 — FOR 1" AND 1-1/4" PIPE AND HANGER TYPE 2 — FOR 1-1/2" AND 2" PIPE AND HANGER STATIC PRESSSURE IN EXISTING SYSTEM EXCEEDS 100 PSI. SURGE RESTAINT IS REQUIRE ON ALL HANGERS SUPPORTING PIPE 12" AND LONGER (NFPA 13 2007 ED.) SURGE RESTRAINT #25 TOLCO FIG. 800 SWAY BRACE ATTACHMENT STEEL I -BEAM FIG. 980 SWIVEL SWAY BRACE FITTING 1' SCH.40 PIPE _FIG. 1001 "FAST CLAMP" SWAY BRACE ATTACHMENT SWAY BRACE ATTACHMENT TO STEEL I—BEAM SHOWN IN LATERAL BRACE APPLICATION SYMBOL= VICINITY MAP APPLE STORE -SOUTHCENTER 84-518'SOUTHCENTER MALL TUKWILA, WA. 98188 PAID SEP 1 1 2008 LOCATION OF STORE N Tukwila Fire 74,26fh CONTRACT Mt SHAWMUT DESIGN AND CONSTRUCTION 560 HARRISON AVENUE BOSTON, MA. 02118 DRAWING TITLE FIRE SPRINKLER TENANT IMPROVEMENT DATE : 8-25-08 SCALE : 1/8" = 1'-0" DRAWN BY : T.N.RHODES 5S D6028 SHEET NO. FS -1 ARAG IRE ARM SYSTEM ADDITION UKWILA, WASHINGTON HJithout COrflinent5 ❑ As .z:; tee:' in kEcl ❑ Per The At -each:-..-- Letter These plans have been reviewed }v The Tukwila Fire Prevention Bureau for ccnfomiarf:r_. T'dth current City standards. Acceptance sub ec t --:(Tors and omissions which do not °a,fi-hori7. ° •racI: ,ails of adopted standards and-ordinancd-s. The iespu :s:oliity for the adequacy of desig'l totally c e designer. Additions, deletioi is or i'evi;o-tOrt i ;,^ thee. drawings after this date will void tn:s ac<:eprai icy; F =?r : 1 require a resubmittal of reviser) drawings for sui {cent approval,. Final acceptance is subject t to field test and inspection by The Tukwila Fire Prevention Bureau. SHEET \UM3ESHEET TITLE FA -01 SYSTEvl 1\FOvATIONN FA -02 TYPICAL WHI\G A\D MOU\TI\G DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LI\E DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX WISE SCHEDULE A\3 CONDUIT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANDERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSCCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE EN\'IRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX EX 3 EX EX SYMBOL DESCRIPTION MODEL Date: • - -1 :' __by; J/ V • I V� BACKBOX NOTICE 4 completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and De;:ection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address for shut- down or r : I tt pproval. MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD -3-ENCL 66" A.F.F. TO TOP ® SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1 G RING CEILING ® D DUCT DETECTOR TSM EX 7 EX HT -R DUCT DETECTOR TEST SWITCH AD2-P W/ SIEMENS DUCT HOUSING HFP-11 DET. TSM -1 SIEMENS 1 -GANG BOX INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD VERIFY IN FIELD VERIFY IN FIELD 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 FIRE ALARM STROBE ZR -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM Di FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1 -1 /2" EXTN HCP INTELLIGENT HCP CONTROL POINT SIEMENS 4S DEEP BOX VERIFY II\I FIELD A.F.F. ABOVE FINISHED N/A FLOOR N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N /A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N /A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND macys LEVELS _5.4O-7s.f GARAGE SPACE #1135 mem, s RELEASE/REVISIONS REV. BY: 0 X DESCRIPTION SHOP DRAWINGS DATE 04/03/13 9a<aaa NORDSTROM 3 LEVELS 171,275st r•3 <<'-1 ?(T.VArk, .,s RARE R,,X ,f; mss; f -i L I Pnr p:4R sr.r�4 r-sa JCPenney tri M T OHO to coW Deo o W <z cn mu) CC z. -J o W • = CC D �+-01- U) ¶;MCAS. ,.,tt, nC,zRE TRE ;r AE PtcAlE • 11.7,47.1 i TAC - •TEAII';:1-0= PAP,C SRWFA4 •[ R,ao MA FRP gR: PA• C.A C yS _ BANv E.r T!; �E�G.e • I� Z,I T.T,,.., 0 Ally PATIO SITE PLAN RESTALPAYT PATO PEP/. PAID r9 (Y--; 7f11 LAM Cc, Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved Z (S -.ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/03/13 BACKROUND PLAN PROVIDED BY: \,1OB NUMBER: 100683} I; SHEET FA -01 } THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE 6-10 DUCT EQUIVALENT DIAMETERS DUCT DETECTOR LOCATION OUTLET SAMPLING TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND AD2-P DUCT DETECTOR MOUNTING DETAIL 0 FROM XLS CONTROL PANEL OR <4- PREVIOUS +PREVIOUS ADDRESSABLE DEVICE END OF LINE DEVICE(3,6K 1/4W) SUPERVISED SWITCH GROUND 0 0 r7 0 HTRI—R OSTATUS LED 0 N. 0 COM 0 1 -F N.C. ' 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. MUSIC LAC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS <4,0A @ 125VAC) (4,OA @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL PREVI❑US ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - 27 VDC 3.5 nA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTION. 1001 TI31 g S g)B e B 1 2 3 4 5 6 TB2 C D oa+-+- 654321 0 JUNCTION BOX —. MOUNTED ON CEILING. FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT / / / / / / / FRONT '/IEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE + DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0- 0 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> T O O 7�5 TO NEXT DEVICE 0 0 —CADDY BAR O f SMOKE DETECTOR \— SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL 0 GND N AC 0 0 0 T 0 PAD -3 0 00 O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 6 24K HCP MODULE ( PAD -3 TRIP) WIRING DETAIL NAC -4 NAC -3 NAC -2 NAC -1 470 OHMS EOL INPUT 0 9 9 T M-1 O V U 3 J rZ o< ZQoQo C_,0 L" � ACU 0 r-.. •ixOOO 0 • 0 CQC AD2-P DUCT DETECTOR WIRING DETAIL FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) EARTH GROUND --.(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE J( ( ) ( ) STROBE SPEAKER (+) NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERATURE: +32'F (0' C) TO 100' F 38' C) }TUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE tDATA IN( )> DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CON,AINCTION %CH DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW TO NEXT DEVICE-r— ( EVICE — ( ) DATA OUT (+) DATA OUT HFP-1 SMOKE DETECTOR WIRING DETAIL (+) ( ) STROBE (+) ( ) STROBE SPEAKER (+)f 0 SPEAKER STROBE & STROBE WIRING DETAIL SPEAKER STROBE OR STROBE ONLY R 0 TYPICAL WIRING AND MOUNTING DETAILS 4S DEEP BOX W/ 1-1/2" EXTENSION RING — ((SPEAKER STROBE) 4S BOX (STROBE ONLY) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE HARD LID 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N Nx \� CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING/WALL MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 04/03/13 ««< J O ct J SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/03/ 1 3 BACKROUND PLAN PROVIDED BY: ..JOB NUMBER: 100683} C SHEET FA -02 GARAGE EXISTING SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: 04/03/13 Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -W @15Cd 3 0.064 0.192 SET -MC -W @30Cd 2 0.098 0.196 SET -MC -W @75Cd 20.175 0.350 SET -MC -W @110Cd 0.233 SET -MC -CW @15Cd 0.069 SET -MC -CW @30Cd 0.111 SET-MC-CW@75Cd 0.2 SET -MC -CW @95Cd 0.264 ZR -MC -W @l 5Cd 1 0.064 0.064 ZR -MC -W @30Cd 0.098 0.03 Amps 0.832 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.832 Amps For 5 Minutes= 0.070 Amp -hours 25% Derating= 0.987 Amp -hours Total System Current Load: 0.987 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Notification Appliance Circuit Detail !PROJECT: GARAGE Panel: 1 EXISTING PAD -3 POWER SUPPLY _... - CIRCUIT:iS1 QTY Device Type . 3 SET -MC -CW @l5Cd 2 i SET -MC -CW @30Cd `>. SET -MC -CW @75Cd j 200 :Wire Resistance 2.58 CURRENT TOTAL= 893 Alarm Current Alarm Total ! Wire Size : Wire Length Voltage at EOL Circuit Total • 69 2071 i 111 222 SET -MC -W @30Cd I SET -MC -W @75Cd SET -MC -W @110Cd 1ZR-MC-W @15Cd ZR -MC -W @30Cd DEVICES=18 CALCULATIONS { 98 175 233 64 98 TOTAL mA= 400 01 oI 01 64! 8931 14 214 19.41391368 893 Total Wire Resistance (R ) (WL*2)*(R/ft) ;Total Device Load, Amps (I)_ (Total Cct Load) 'Voltage Drop ( E ) (E= I * R) ;EOL Voltage (24 - E) 0.89£ 0.99 23.011 TO BUILDING FIRE ALARM CONTROL PANEL TO EXISTING DATA LOOP (MALL CORRIDOR) EX BPS J S1-1 S1-2 30cd 15cd V-1 S S1-3 15cd V-2 S1-4 15cd V-3 EX EX S1-5 30cd V-4 D b S1 -6 75cd V-5 SINGLE LINE DIAGRAM EX EX S1-7 15cd V-6 S1-8 75cd V-7 EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. REPLACE EXISTING DUCT DETECTOR WITH NEW DUCT DETECTOR. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. W - CD O` co 0\ c0 z •N O o z C\, a Q W w O �i U.) 1-0 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS uJ I- < 0 04/03/13 - ®C oC 0 W `i ..I T .4;W 0WT- L— < oo_z z W < 4 7) CD w , zS Q 2_ cr W Q C!) Q 2 l— z O °CW 0 dig W= CCDD 01— C CO CO 0 W C1) �-- (1) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/03/1 3 BACKROUND PLAN PROVIDED BY: ..JOB NUMBER: 100683 FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET D• ACENT TENANT FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. REPLACE EXISTING DUCT DETECTOR WITH NEW DUCT DETECTOR. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 7 ;cKw1,Z _ . CKROOli (DOOR S1-5 30cd V-4 S,V,V Si -2 15cd S,S' EX S1-7 15cd V-6 v,v S1-1El<IN ® EX 30cd V-1 s EX HCPI =-1-= j A S1-3 15cd V-2 BPS vA s,v,v' HT -R. / f s,v,v' i` ri d -TING JOM .REA �. S1-6 75cd Liq V-5 SALES AREA SA S1-8 EOL 75cd S1 V-7 ENT S1-4 15cd V-3 _ J?!'�`lx\��Y/�\I.�YT 1F7��r'�kf� kT�%?.�l'"�>7••./ t AOJACEN i ENAN1 FIRE ALARM SYSTEM PLAN 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE M M 0 •10 Z 472 p W SS 0 Cn Z WQ JO w rz . wQ �w� Q U_ W I- cc Dn (1) Cr) M ✓SCALE: 1 /4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/03/13 BACKROUND PLAN PROVIDED BY: ,JOB NUMBER: 10068 C SHEET Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved \ FA -04 J APPLE NEW HVAC UNIT FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON ❑ Pef Letter These plans have been reek,:wei by The Tukwila Fire current City :st,nrds. Accept nce is .;so)ect to errors and o...:ii5sions which ai not mutt orizc violationF.--: of adopted s,1zIndarcls and orr'_:.:ances. The respor4ibility for the jacy of desigF: tests totaiiyth t; designer. _ion's d1 Ietif s rci revisions to i i'; 'r (ir 'A'!r gs after t. :.ate will void till;S:.il.'.: jl i �(;.: •�'.:. _ •'iii reg_iire a ii suornitt i cif revis;�.c° 4: ;,,,;,.:. r,�r ..1.,. ;,�,.,`i: approval. nat acceptance is subject to f:e!o cast and InspeCtion•ly 'hie Tukwila Fire Prevention Bureau. Date: / - `I -I By: sl( ,...ate SHEET NUM3E SHEET TITLE FA -01 SYSTEIV INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SI GLE LINE DIAGRAM FA -04 FIRE ALA M SYSTE vl PLA\ SHEET INDEX WI SCHEDULE A\D CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPUFPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vaC POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDU T. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS JSING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY. ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WI -ERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX EX 1 1 1 EX EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of - f_.:_.e2l o=nce Testing of any FireA:3!-ti and Detection ` y,tierts:c Failur-eort::�t�'!'�,..:..Ir i a Fec and ',Y31-rnTn?,t1.0fi of the testinn TUKWILA FIRE.: 1- l F, ► Please caf 4 -1�y ,' C5 yf 6&:t1 give Liliz Fire 1-F-aq and down or MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1 G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS DUCT HOUSING HFP-11 DET. VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM F HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM ❑L STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND AKA mervynis 2 LEVELS 65,23: s1 : �� NORDSTROM3LEVELS L `,l 1 7/ 171,2:55= APPLE #801 ANC: COLT., te'A�r Si`.ER. 3 IXEO GATLIGLA.oltMs =:C nun. srktu Es ECST NC JCPenney W4ICENROCICS vE ±_C T ESS MACE el a'ISf9.".1e sae.:ER C,F75 r~- ICn;'E PEtRII .I UDD- icCO YA' . p11111 N 2 e VA TEAM voR 276,468sf AFEP.CROMSE PI-JitC SUN/F_IR IC251 05174 STAIRS TRW ` ..F. . EMERALD CNY 4 - } SITE PLAN PAID ivriv 25 2013 TUKWILA FIRE 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE M In N 2aa<aa 1 1- Z z D o J� ~ d0) U o2z = wzz wx< vcn z oC W J cc Cl. LL F- 0 0 SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 /25/1 3 BACKROUND PLAN PROVIDED BY: \OB NUMBER: Pro rieta and Confidential, Co. ri•ht 2012 b Guardian Securit S stems, Inc. All Ri• hts Reserved 7399-1j SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ DEDICATE) EMERGENCY —( NOTE FOR ADIXDONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 'CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC I TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE PROM XLS COMM PANEL DR PREVIOUS ADDRESSABLE DEVICE O 4 GROUND HTRI-R 0 O o O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) ORD N L 00 00 0 PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0] a m m a m e 3.6k EOL (-) (+) (-) (+) SPARE , SPARE SPARE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) O WIRE DESIGNATION; NUMBEROF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPLIFPLR RED(JACKET) *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O r 4 1 0 0 0 1 HTRI-Rr, 1 rc\0 GROUND O �� (+)>TO NEXT DEVICE OR (-) > STOP IF LAST DEVICE DRY CONTACTS TO VAV �► FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FLED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL (+) HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY U U HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERATURE: +32' F 0' C TO 100' F (3& C) HUMIDITY: 9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR — FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE r DATA IN( )> 5l DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL 00 00 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX • ^4 `.s+�.Lbye£.a.u`.�.� :+.�j�.�1i�i�a�tst`a� � 4' �eey�d.. 4 v JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT 0 0 r 0 0 TO NEXT DEVICE CADDY BAR E1I SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS M W a o N zco o JO L dO) dQuo = w z z 5?Vt=j) Z LL Qog Wup- wT C4 CLL., 0 �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:1 1 /25/ 13 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 7399-1) r SHEET FA -02 Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 1 0.0635 0.0635 0.064 0.064 HTR -R 0.009600 0.0096 0.021 0.021 0.0731 Amps 0.085 Amps SYSTEM CALCULATIONS CS L LTJ EX EX EX EX EX EX EOL S2 j D FLAG NOTES: DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. v "3 . 1,0 co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE :->2) N 2 aaaa< cc 0 w Z w z 22 D o � (5 Q� U �z < ¢ o �- 0 w� I w zz Z w= aC � U u)W i< (1) Zoc�� Z QHS 0 LlJ w CL J U w Ci) >- Cl) �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:1 1 /25/13 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM ..JOB NUMBER: 7399-1/ SHEET Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved FA -03 J `®" (u' EX EOL S2 EOL S11 EX EX 1-1 s. —G CD PS D ?S EX EX cS FLAG NOTES: DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. v u 1 i ®t EX AREA AREA OF 7 WORK FIRE ALARM SYSTEM PLAN Li 2S EX EES 1 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 3 0 DESCRIPTION SHOP DRAWINGS DATE 11/25/13 2<aaa< " Z 0 Z Z c0ss O _Iv � �z Q o (/) > Q FEF - u) w zZ ( cn (/) Lux x< z�g�- od W w o CC J c co n CLuJ CC �CALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:1 1 /25/ 13 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 7399-1; ( SHEET FA -04 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved APPLE SOUTHCENTER FIRE ALARM SYSTEM TU ILA, WASHINGTON Without Corn tccit ❑ As Noted in Re ❑ Per The Attach &.:. Letter These plans have been reviewed by Me Tukwila Fire -evention Bureau for conformance v,:;rn; current City ndarcis. Acceptance is subject to:if rors and -.nissions which do not authorize violations ::f adopted - . 7.:ndards and ordinances. The responsibility for the ..dequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after SHEET # DESCRIPTION FA -01 SYSTEM INFORMATION/SINGLE LINE DIAGRAM/REMOTE BREAK ROOM FIRE ALARM PLAN SHEET LIST QUANTITY E(2) SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT gE FIRE ALARM HORN STROBE (EXISTING) SLHSCW—F SIEMENS 4S BOX CEILING JUNCTION BOX F.B.O. F.B.O. N/A VERIFY LOCATION IN FIELD E❑L END OF LINE RESIST❑R N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.D. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U,❑.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND RELOCATE TWO(2) EXISTING HORN STROBE OF THE FIRE ALARM SYSTEM. SCOPE OF WORK FROM EXISTING S NAC DEVICES S 3E S1-1 75Cd S S1-2 75Cd EOL S1 RELOCATE EXISTING NAC DEVICE TO NEW SPECIFIED LOCATION. MAINTAIN CIRCUIT CONTINUITY. EXISTING DEVICE RELOCATED TO THIS POINT OF ROOM STORAGE. FROM EXISTING NAC DEVICES REMOTE BREAK ROOM FIRE ALARM PLAN SCALE: 1/4"=1'-0" NORTH CEILING TILE e. resubmittal of revised drawings for subsequent approval Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: / 9 By: A --wt s>" I SPEAKER SUPPORT BRIDGE Fire Permit Number ' �`,c.' ': �t ons To sc� �.��.:�� i��r,c:, call 206-575-4407 4" SQUARE DEEP BOX WITH 2-1/8" EXTENSI❑N CEILING MOUNTED SPEAKER HORN STROBE MOUNTING DIAGRAM (DROP CEILING) HARD LID CEILING SPEAKER SUPPORT BRIDGE 4" SQUARE DEEP BOX WITH 2-1/8" EXTENSI❑N CEILING MOUNTED SPEAKER HORN STROBE MOUNTING DIAGRAM (HARD LID) TYPICAL MOUNTING DETAILS EXPIRES 09/01/2020 1,0 co 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: U m c4 DESCRIPTION SHOP DRAWINGS DATE 12/04/19 CC w co z1 07, Z a) w w 2z O CO wI E �zz E— 2 w = D cc 2u) O Q�� wo Ill �0 a�� 0 N C) CC LU CC LL rn C• C Q C=1 LLI CDCry CC CD LLI CALE: NOT TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 12/04/1 9 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved .JOB NUMBER: 49371—.1} SHEET FA -01./ SDE E S blgelmsi{y-fort f App[i'anc "Stiro ®e' itiiiteet En iiM seclfrcat a s ❑ Sophisticated series of notification appliances that meets fire -industry codes and regulations for commercial -building applications ❑ Compatible with the Siemens 50 -point, 252 -point and 504 -point addressable fire alarm control panels (FACPs), and with: Siemens Modular FACPs - Siemens PAD -series of NAC extenders - FireFinder® XLS /XLSV FACPs - Siemens dual -sync control (DSC) modules ❑ Innovative LED strobe technology provides an energy-efficient means for a significantly reduced current draw - Capabilityto have existing Xenon and new LED strobes in the same field-of-view - Fewer power supplies required, smaller wire gage, reduced wire runs ❑ Straightforward installation coupled with compact, modern design - No visible mounting screws Manual (index finger) slide -setting adjustor - Four (4) field -selectable settings in one (1) device: 15cd130cd1 75cd j 95cd ❑ Faceplates ship in four (4) distinctive types: - "FIRE" 1 "ALERT' J "AGENT" j (blank) ❑ Two (2) audible settings in each notification appliance - Temporal or steady horn output - High or Low setting ❑ UL (2034 1971 1464) and ULC Listed (ULC -S5251- S526) - ADA 1 NFPA( FCC 1 ANS11 OSHA compliant Siemens Building Technologies Division Pro uc Clvenrie� Formed as the 'SL' -series, Siemens is now offering horns, strobes, and horn -strobes to its notification -appliances portfolio. With the 'SL' -series, Siemens now offers an additional range of products with low and high candela settings that makes these sophisticated notification appliances ideal for new installs and retrofit applications. Innovative light -emitting diode (LED) strobe technology provides an energy-efficient means for a significantly reduced current draw. The strobe portion of these appliances meets the 20 millisecond light -pulse - duration requirements of the 2016 edition of NFPA 72. This feature allows existing Xenon and the new LED devices to be used in the same field-of-view. In a single device, the 'SL' -series can provide alarm -signaling tones for dual applications. All strobe models in the series feature multi -candela settings (15 30 75195cd) on a single appliance. Additionally, there are two (2) modes of operation for the audible portion of these notification appliances: • T3 (coded) • Continuous The 'SL' -series of horns, strobes and horn -strobes devices are produced in a sleek, modern design. Its structure and design provide high-quality energy efficiency in an aesthetically pleasing, low -profile design that is consistent to the look of the interior composition of the building application. This 'SL' -series is exclusive to indoor ceiling -mount applications. The Model 'SLHC'- series horn appliances work in either 12V or 24VDC, whereas the Series 'SLSC and 'SLHSC strobe and horn -strobe devices are specifically for 24V operation. ModetFSLHSCR'F Horn -strobe ModeliSLSCW.AL Strobe Model;SLHCR-N Horn Data Sheet 2594 usa.siemens.comlfire SLSHCISeries Ceiling Horn -Strobe sSL"HCSeries1 Ceiling Horn • ec fiMi ns w � In terms of composition and functionality, Models 'SLHC '-series, 'SLSC '-series, and 'SLHSC' series provide added value to the installer for the type; of applications for operation: • Compact I sleek I low -profile design • Comprehensive feature list • Convenient mounting options • Easy -to -adjust selection -slider switch for candela settings — No tools required for setting changes — Multi-level settings: 15cd 130cd I 75cd I 95cd • High and Low audible outputs • Reduced current draw, via cutting-edge LED technobgy The LED portions of the Siemens 'SL' -series of strobes and horn -strobes meet the 20 millisecond light - pulse -duration requirements of the 2016 edition of NFPA 72. By meeting this latest requirement, existing Xenon as well as the new LED -technology devices can now be in the same field-of-view. The horn, strobe and horn -strobes in this Siemens 'SL' -series of notification appliances have received UL / ULC Listed status by attaining compatible testing standards with all of the Siemens fire -alarm control panels (FACPs) and accessories that have been determined to be aligned with existing Siemens strobe -based appliances. This would include the following existing model -types: 'CH' 'HS' 1 'MTH' 1 'S -HQ' 1 'AS' 'SE' 1 'SEF' 1 'SET' 1 'ST' 1 'STH' 'ZR' and 'ZH' Series notification appliances. The regulatory listing also includes the capability for installing the Siemens 'SL' -series sounder -strobes in the same notification zone and field-of-view with any existing Siemens Notification Appliance Xenon -based strobes. All these horns, strobes and horn -strobes models are UL Listed (for indoor use under Standard 1971 and 464), as well as ULC -5525 ULC -5526 Listed. The Siemens 'SU -series sounder -strobes also have ADA 1 RoHS and ICES approval. Siemens Building Technologies Division —2— usa.siemens.com/fire ti `Ele tricalRain • s Ceiling -Mount 1 Horn -Strobes Output Current Draw MODEL 'SLHSC' SERIES:' UL Current Ratings (HIGH dB 1 in Amps) 16.0 - 33.0 VDC Setting 15cd 75cd 195cd Code 3 0.044 0.065 0.182 0.268 Continuous 0.049 0.067 0.187 0.274 MODEL 'SLHSC' SERIES: UL Current Ratings (LOW dB 1 in Amps) 16.0-33.OVDC Setting 15cd ' 30cd 75cd 195cd Code 3 0.042 0.064 0.181 0.256 Continuous 0.045 0.066 0.183 0.271 Ceiling -Mount 1 Horn -Only Output Current Draw MODEL 'SLHC' SERIES:` Current Ratings (Code 3 I in Amps) RMS Current @ 24 Volts DC Regulated Voltage Range, VDC 8.0-17.5VDC High Low 0.024 0.018 16.0-33.0 VDC 0.030 0.022 Ceiling -Mount 1 Strobe -Only Output Current Draw MODEL 'SLSC' SERIES:' Current Ratings (in Amps) RMS Current @ 24 Volts DC Regulated Voltage Range 15cd 30cd 75cd 95cd 16.0 - 33.0 Volts DC 0.040 0.058 0.171 0.256 GENERAL NOTES: 1. Strobes are designed to flash at 1 -flash -per -second minimum over their "Regulated Voltage Range." 2. NFPA-72 specifies a flash rate of 1 -to -2 flashes -per -second, and guidelines for the Americans with Disabilities Act (ADA) specify a flash rate of 1 -to -3 flashes -per -second. 3. All candela ratings represent minimum effective Strobe intensity based on UL 1971. UL ( Ceiling -Mount 1 Horn -Only I Output Current Draw MODEL 'SLHW'- and- 'SLHSW' SERIES:' UL Sound Output Ratings (dBA) Reverberant per UL464 @ 10 feet Volume SLHC @ 12VDC SLHC -and- SLHSC @ 24VDC 8.0V 12.0V 17.5V 16.0V 24.0V 33.0V i I Code 3 I High dBA 75 80 83 76 79 81 Code 3 1 Low dBA 73 77 80 75 77 77 Continuous I High dBA 80 84 87 80 83 86 Continuous I Low dBA 78 79 84 78 81 81 ULC 1 Ceiling -Mount 1 Horn -Only 1 Output Current Draw MODEL 'SLHW'- and - -SLHSW' SERIES:' ULC Sound Output Ratings (dBA) Anechoic per ULCS525-16 @ 3.05 meters Volume SLHW @ 12VDC SLHW -and- SLHSW @ 24VDC 8.0V ( 12.0V 17.5V 16.0V 124.0V 133.0V Code 3 I High dBA 85 89 92 91 95 96 Code 3 I Low dBA 79 84 87 86 190 91 Continuous I High dBA 85 89 92 91 94 97 Continuous I Low dBA 79 84 87 86 90 92 'RMS current ratings are per UL maximum RMS method UL max curren rating is the maximum RMS current within the listed voltage range (16 - 33V for 24V units) For audible appliances, the max current is usually at the maximum listed voltage (16.33V for 24V units) For unfiltered FWR ratings, see installation instruction General Properties OPERATING TEMPERATURE: MODEL "SL' -series - 32°F (0°C) to 122°F (50°C) - for indoor -applications' use only RELATIVE HUMIDITY: 93%, maximum OPERATING VOLTAGE RANGES: - 12VDC/VFWR -) 8-17.5VDC/VFWR; - 24 VDC / VFWR e 16 - 33 VDCNFWR (12 VDC for Model SLHC only) STROBE OUTPUT RATING: - UL 1971, ULC -S526 - Field -selectable 15cd 1 30cd 1 75c 1 95cd candela outputs STROBE FLASH RATE: Strobes are designed to flash at one -flash -per -second STROBE SYNCRONIZATION: - all Siemens addressable panels - Siemens PAD -series NAC extenders - Siemens dual -sync (DSC) modules, which provide the unique Siemens proprietary synchronization protocol TEMPORAL PATTERN: - Continuous - Code 3 (1/2 second on, 1/2 second off; then 1h second on, 1/2 second off; followed by 1/2 second on, 1-1/second off and repeat) NOTES: The Code 3 pattern is specified by ANSI and NFPA 72 for Standard Emergency Evacuation Signaling. Physical Properties MATERIAL: MODEL 'SU -series - White -or -red textured, ultraviolet (UV) stabilized, colored impregnated engineered plastic - Exceeds 94V-0 UL flammability rating WEIGHT: 0.55 Lbs. (0.25 Kg.) LENS TYPE: 'J LED strobe situated in a rugged Lexan lens DIMENSIONS: 3.13" (7.95 cm.) { H }; 3.13" (7.95 cm.) { W }; 1.5" (3.81 cm.) { D } Mounting and Wiring Properties INDOOR MOUNTING: MODEL 'SU -series - Ceiling -mount applications - Model SLSBBC backboxes or to 4' (10.2 cm.) square - 1.5' (cm.) -or- 2.125' (cm.) octagonal - 1.5' (cm.) -or- 2.125' (cm.) deep WIRING TYPE:F'12-e18,American Wire Gauge (AWG) Siemens Building Technologies Division -3- usa.siemens.comlfire NOTICE - The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets — as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product. All are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contac the Manufacturer. SIEMENS dddlIllddddddddiP'.ddPdddddddtdddddd%ld,o'ddddd'dd ...„................ ",dgdddddd!K.,d,!d, iemen industry, ec 0 ogle Division MODEL PART NUMBER APPLIANCE TYPE LJL El MOUNTING TYPE STROBE TYPE FACEPLATE FACEPLATE _ COLOR LETTERING SLHCR-N S54329 -F12 -A1 Horn 1 V Ceiling -None-- RED VI - None - 854329 -F12 -A2 1111511111113111 -None-- IIIIIIIE—:in ill - None - SLHSCW-F S54329 -F13 -A1 Horn -Strobe 1 — C ei I i n g allarill WHITE FIRE SLHSCR-F S54329 -F13 -A2 mini RED FIRE SLHSCR-FB S54329 -F14 -A1 Horn -Strobe 1 Ceiling Clear RED ' , - Pictogram - SLHSCW-FB S54329 -F14 -A2 V ME= IIIIIZBBEIII -Pictogram - SLSCW-F S54329 -F15 -Al 1 — IIMENIIIIIIEZIEMIE FIRE SLSCR-F S54329 -F15 -A2 Strobe 1 — Ceiling am. RED : ,111111111110311111111 SLSCW-FB S54329 -F16 -A11 Strobe Ceiling Clear RED - Picto ram - SLSCR-FB S54329 -F16 -A2 im. 1 NEE= Nmszmi _ Pictogram - SLSCW-AL S54329 -F17 -A1 1 1 IMEMENIMICEMII ALERT SLSCR-AL S54329 -F17 -A2 Strobe '1 MEN Ceiling mom. RED 'I1 ALERT SLSCW-ALA S54329 -F18 -A1 Strobe 1 1 Ceiling Amber WHITE ALERT SLSCR-ALA S54329 -F18 -A2 1 1 Amber RED k Ut ALERT SLSCW-NA S54329 -F19 -A1 Strobe 1 1 Ceiling Amber IIIIIIIIIIMMIM - None - SLSCR-NA S54329 -F19 -A2 1 MEM Amber RED ' , - None - SLSCW-N S54329 -F20 -A1 Strobe 1 — Ceiling Clear 11111E4'11EMEI - None - SLSCR-N S54329 -F20 -A2 1— ma= RED , - None - SLHSCR-A S54329 -F32 -A2 Horn -Strobe 1 1 Ceiling Clear RED ,, AGENT SLHSCW-A S54329 -F35 -A2 i 1 MIEIMIIIMIIEEEIIIIIIIMCEEBIIIIIII SLHSCR-AL S54329 -F33 -A1 Horn -Strobe 1 1Clear Ceiling RED , ALERT SLI -AL S54329 -F36 -A1 1 MIMI WHITE ALERT SLHSCR-N S54329 -F33 -A2 i — Ceiling Clear RED , . - None - SLHSCW-N S54329 -F36 -A2 Horn -Strobe 1 — 11113,1111111MINEM - None - SLSCW-A S54329 -F65 -A1 1 I C ei I i n g Clear IH AGENT SLSCR-A S54329 -F37 -A2 Strobe 1 1 _ immin SLSBBCR S54329 -F55 -A1 v 1 Ceiling -None- RED , „. - None - S LS BBCW S54329 -F55 -A2 Backbox V V -None- WHITE - None - NOTICE - The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets — as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product. All are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contac the Manufacturer. SIEMENS dddlIllddddddddiP'.ddPdddddddtdddddd%ld,o'ddddd'dd ...„................ ",dgdddddd!K.,d,!d, iemen industry, ec 0 ogle Division 801 SOUTHCENTER MALL ASSOCIATED PERMITS 19-F-242 19-F-230 13-F-291 13-F-084 08-F-459 08-S-454 08-S-384 SITE LOCATION 9202470010 King Co. Assessor's Tax No.: Site Address: outhcenter Mall, Tukwila, 98188 Suite Number: Floor: Tenant Name: f V New Tenant? El - Yes ❑ - No Pro a owner's Name: Westfield Property ax Dept. p r'h Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 E-mail Address: kveliz@guardiansecurity.com Total number of new/relocated devices or sprinkler heads City State Zip Fax Number: 206.628.4990 Valuation of Project (contractor's bid price): %' a Scope of Work (please provide detailed information): Low Voltage: Installing New HVAC Unit. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING I Old AUTHO ' ; AGENT: Signature: Date: Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 44"444 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 4MM I�Il2`�q FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Site Address: t Tenant Name: ��r _,, at, p Property Owner's Name: \3 V 4 WlS Mailing Address ��CG **PLEASE PRINT** King Co. Assessor's Tax No.: ` CAtk(OO ( t Suite Number: e(p Floor: New Tenant? ❑ - Yes [a.- No C' K\A`cnA cvnk3 CONTACT PERSON -if there are questions about the submittal. City State Zip Name (QA.Thi% ()AI� 11Day Telephone( ) ; �p Company Name: 1OS C&Y& `--)Q.00C Mailing Address:\1 J \* ��(�' , %j \i4F 144k.7.)4 - City State Zip E-mail Addressi ATU �k(�iY hai300Q,1IQAa �kO tX(\ Fax Number: �f J `Contractor's City of Tukwila n NICET III number: Business License number:. c) -4 , Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $A.1��r5 — Scope of Work (please provide detailed information): ' (1 \CkX \ 4j i ' , c ,Q)Acu„A cx-oq, ` \-k(odAut ( 1 )cit% lcki. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ'AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O ER OR AUTHORIZED AGENT: e: Signatur 0�� 1i Date.1 `! 1 a] ( q Print Name: jaq,,P, V\ Day Telephone: (2. (.U) CQ19 - 3 Plan Permit App.doc 8/22/14 TFD FP Fonn 8 GUARDIAN SECURITY Customer LIFE AND PROPERTY PROTECTION Apple 801 SOUTHCENTER MALL TUKWILA, WA 98188 I —.sect Apple Project # List of Materials Vendor Guardian Security Systems Inc 1743 1st Ave. South Seattle, WA 98134 Phone #: (206)622-6545 Fax #: (206)628-4990 Type of Equipment FIRE ALARM Date: Sept,08,08 Item Qty. Manuf. Model Description Unit Pri Total Price 1) Siemens PAD -3 2) Siemens AD2-P 3) Siemens HTRI-D 4) Siemens HTRI-R 5) Siemens ZH CW,W 6) Siemens ZR-MC-W,W 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) t1) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) 33) 34) 35) 36) 37) 38) 39) 40) 41) 42) 43) 44) 45) 46) 47) 48) 49) 50) Power Supply for Strobes with Standby" Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 Supervised Addressable Input Module Supervised Addressable Output Relay Module Interior Audible Horn Strobe Annunciator Interior Visual Strobe Annunciator Conduit Systems: All smoke removal and detection and control devices in an approved metallic raceway and all devices in conduit per Standard I XI 18 08 10:09a NW Fire Systems I UKWILA FIRE DEPART:UL1111, PI a give this job N.. o g_S 32L1 a exact address' for shut, o n or r9st3ratiorl ao rO4A vPvrf I insp hun prior appr NOVICE LUti / 12 bU4 p.� AREA OF WORK ainisnryr; Cr' stamps must, aped before pipe is . Mint paintirpipinti'�. to hydro tate test )VOL _1 } MALL CUT do GROOVE EXISTING 31/2" i RISE UP CROSSMAIN K lMthout Comments 1; Doted In Red 0 Per The Attached Letter i ti...eneen. nese plans have been reviewed by The Tt.kwila Fire Qrev4ntion Bureau tor conror;rance v,:tr cu rent city standards. Apaice is tc ericis pnd omissions which dD not dut'torze vio:3tic-.s :.:f adopted standards and or l,rlances. PIE !e ;;>r4 -., , t� for the adequacy of desiq re 15 ner. Additions, deletions or ; ev.sioris �'_: '";s• :e dniwtr,gs i ?r Thi Pwill void t?"i., ._x_�F• ;tl!icc= lU v ii require a resubmittal of reviled irawsnngs for s:ub equ:nt approval. Final acceptance Ira subject to f;eld test and nspection by The Tukwila Fire Prevention Bureau. Date: 7^i By: LASTING 311:" CROSSM N \' NEW 8 BEAM l EXISTING MAIN AT 12'-101. BOTTOM MAIN TO BE RAISED TO MAINTAIN 13'-3" BOTTOM MIN. ROTATE MAIN 90 5O RIFTING SIDE OUTLETS FACE UP — RECUT 1" 8::1W PIPE TO RECONNECT RELOCATION PLAN SCALE: 1/8" = I®HTIWESlfldf SYStMMSfIB 406 Steven AMMO NLA, Re tan, WA 98057 2067727602 • I z 206272.7504 IP V.nwlirssrd.mstom • LK 15 NORTHFS92aCR IIMININIIIMMINIP011111.0.311111011~111111001.ir <1.000•10114 T iririir /ALIVIli 7/ 8c GENERAL NOTES SCOPE OF WORK: RAISE EXISTING CROSSMAIN FOR NEW TENANT CEILING ALL WORK PER N.F.P.. f13 STANDARDS ALL MATERIALS SHALL BE NEW AND U.L LISTED OR F.M. APPROVED ARE SPRINKLER SYSTEM 1O BE INSTALLED. BRACED AND TESTED IN ACCOURDANCE 11(1H N.F.P.A. X13 WESTF1ELD MALL -- APPLE STORE 801 S011THC N1ER MALI TUKW A, WASHINGTON, 98188 DATE: 7-08 DRAWN: G.B. SCALE: AS NOTED 1 OF 1 FILM Cnpy w 1 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Apple Store 801 Southcenter Mall Permit No.: 08-S-454 Date: September 16, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • These conditions apply to any sprinkler piping exposed as necessary to accomplish the permitted scope of work. All references are NFPA 13, 2007 Edition. flZOflFfl6IflRIfl6 15 September 2008 Niki Rhodes Cosco Fire Protection 15000 Woodinville -Redmond Rd NE Woodinville, WA 98072 Tuazon Engineerin% PLLC 4322 NE 7 Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com RE: Westfield Mall — Apple Store Independent Third Party Review — Fire Sprinkler System Dear Niki: As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. The following was reviewed: • Fire Sprinkler Drawing — Sheet FS -1 dated 8-25-08 • Hydraulic Calculations • Product Data The documents were reviewed for compliance with 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. Hydraulic reference nodes should be added to the plans in accordance with NFPA 13 Para 22.1.3.(34). 2. Revise general note 1 to list "City of Tukwila" requirements. A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or ericauazon.com with any questions regarding this review. Respectfully, TIJAZON ENGINEERING, PLLC Eric P. Tuazon, PE Fire Protection Engineer C `,Gummy Fb910013PyecM2008 16 Cam - WstlW Apple Sbidl 5cepos Wan aniUswow eke Jul 18 08 10:09a ' NW Fire Systems NORTHWEST FIRE SYSTEMS SPRINKLER & EIRE ALARM 2067727504 Saving Lives, Protecting Property Fax Transmission Cover Sheet p.1 This facsimile transmission may contain confidential and/or attorney/client privileged information belonging to the sender. This information is intended only for the use of the individual or entity named on this transmission sheet. If you are not the intended recipient, or the employee or agent responsible to the intended recipient, you should return to sender immediately. You are hereby notified that any disclosure, copying, distribution or the taking of any action m reliance on the contents of this telecopied information is strictly prohibited. • Fire Sprinkler Systems Date: July 18, 2008 • Fire FA:imiuishers Company: Tukwila Fire Department • l.:nzergency IAttention: Fire Sprinkler Plan Reviewer • Installation Fax No.: 206-575-4439 • Inspection From: Clark Potter at Northwest Fire Systems LLC • Repair Subject: Main relocation and shutdown at Westfield Mall • 13a6.11ow Preventors No. of Pages (including coversheet) 2 • l laxard Analysis Hello, • Systems I)esi n. Modification. & Specification • ('orrosion Control I called yesterday and spoke with the receptionist regarding this small system modification at the front of what is going to be the new Apple Store at Westfield Shopping Center. We put together a small drawing showing the raising of the 3-1/2 inch main at the front of the store to get the height up about 1 foot higher. Please let me know if this works or if you need anything else in order for us to do this work. Clark Potter 406 Stevens Avenue NW, Renton, WA 98057 • Office: 206.772.7502 • Fax: 206.772.7504 • www.nwfiresystems.com _ _ _ Fire Protection by Computer Design COSCO FIRE PROTECTION 15000 WOODINVILLE-REDMOND RD. SUITE B-800 WOODINVILLE, WA. 98072 425-686-6300 Job Name : SD6028-APPLE STORE SOUTI-(CENTER Building : SouthCenter Mall - Tukwila, WA Location : Space #548 System : TIE to EXIST. Contract : 25SD6028 Data File : SD6028 C.wx1 COSCO FIRE PROTECTION Page 1 SD6028-APPLE STORE SOUTHCENTER Date 082808 Hydraulic Design Information Sheet Name - Apple Store Location - Space #548 Building - SouthCenter Mall - Tukwila, WA Contractor - Cosco Fire Protection Calculated By - T.N.Rhodes Construction: ( ) Combustible (X) Non -Combustible Occupancy - Ordinary Hazard for Mercantile S Y S T E M D E S I G N Date - 8-28-08 System No. - TIE to EXIST. Contract No. - 25SD6028 Drawing No. - FS -1 (loft) Ceiling Height - 11'-0" (x) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve Other Add additional Flow as required to make demand meet 650 gpm. Specific Ruling Made By Tukwila Date Area of Sprinkler Operation Density Area Per Sprinkler Elevation at Highest Outlet Hose Allowance - Inside Rack Sprinkler Allowance Hose Allowance - Outside Note - 1500 - .20 - 113 - 11.00 - 0 - 0 - 0 System Type ( ) Wet ( ) Dry ( ) Deluge ( ) Preaction ( ) Other Sprinkler/Nozzle Make Victaulic Model V2700 Size 1/2 K -Factor 5.6 Temp.Rat.155 6'-0" Flex Drops = 28 eq. ft. Calculation Flow Required - 900.75 Press Required - 66.402 SRC Summary C -Factor Used: 120 Overhead 120 Underground W Water Flow Test: A Date of Test T Time of Test E Static Press R Residual Press Flow S Elevation U 140 20 10900 0 Pump Data: Rated Cap.- @ Press - Elev. - Tank or Reservoir: Cap. - Elev.- Well Proof Flow P Location - P L Source of Information - Y C Commodity O Storage Ht. M Storage Method: M Solid Piled Class Area Location Aisle W. Palletized o Rack ( ) Single Row S R ( ) Double Row T A ( ) Mult. Row O C R K Flue Spacing A Longitudinal G ( ) Conven. Pallet ( ) Slave Pallet ( ) Auto. Storage ( ) Encap. ( ) Solid Shelf ( ) Non ( ) Open Shelf Clearance:Storage to Ceiling Transverse E Horizontal Barriers Provided: Water Supply Curve (C) W 1— Z Z 0 1— C.) III LU CC 0I- U aJ w0 rxa LL Q Oc U U Op U V) N tp f6 N O z - N C u Q.' c 0 c B E E0 E E rn f6 N N 'D N N f0 N W � Q 0 T Tvv 2 W (/) V) (/) T y y 412 '—NN 0 0 1p 2000220V) E N 0 c1 D2 r , C2 �.w,..D1...... � .... I .... � .... I' .... . . . . . . . 1 . . . . . . . . . `. . . . . . . . . . . . . . 1 . . . . 150jb WA% ndf500 6000 7500 9000 10500 12000 13500 FLOW (NA1.85) 0 0 0 0 0 0 )() M N 0 0 O 0 0 (O 0 0 0 COCM 0 d 0 W U (A 0 W O N O now Diagram COSCO FIRE PROTECTION Page 3 SD6028-APPLE STORE SOUTHCENTER Date 082808 70.1 22.9 S3 2 ->1->S2->S1 46.7 1 70.1 1 47.4 S5 4 ->3 ->S4 % 23.5 1 117.4 1 69.2 22.6 S8 6 - 5 -> S7 -. S6 46.2 1 186.6 1 70.4 23 S11 8 - 7 - S10-> S9 47 1 257 1 72.5 23.7 S14 10 9 -> S13-> S12 ? 48.4 329.5 1 26.2 26.2 12 -->11 .16 -> S15 26.2 355.7 13 650 TEST Fittings Used Summary CC W 1- z W U 2 H Z 00 F= U W 01- CC CO aJ W 0 cc d LL < 0c6 U N 00 U (/) N O N co CO v 0 W 10 M N d a m aCi z J • C lL Q CO ( r 0 ✓ CO I"- O N (0 N 0 N 10 0 0 • M 'Cr 0 � M fV 10 • N 0 0 N O O N V aD Mt0 N V) N N CO WI - Units Summary U w cC y G � 0 CTQ C a 0 • N CD C 0L:d c c u, c d 0 E 2 N c o 2 O3 LT 0_ Pressure / Flow Summary - STANDARD COSCO FIRE PROTECTION Page 5 SD6028-APPLE STORE SOUTHCENTER Date 082808 Node Elevation K -Fact Pt Pn Flow Density Area Press No. Actual Actual Req. D001 11.0 5.6 16.29 na S5 11.0 K = K @ EQ01 23.66 na S8 11.0 K = K @ EQ01 22.0 na S11 11.0 K = K @ EQ01 22.77 na S14 11.0 K = K @ EQ01 24.16 na S3 9.0 K = K @ EQ01 22.58 na S4 11.0 K = K @ EQ01 22.89 na 3 14.66 23.69 na S6 11.0 K = K @ EQ01 21.18 na S7 11.0 K = K @ EQ01 23.03 na 5 14.66 22.78 na S9 11.0 K = K @ EQ01 21.92 na S10 11.0 K = K @ EQ01 23.83 na 7 14.66 23.63 na S12 11.0 K = K @ EQ01 23.26 na S13 11.0 K = K @ EQ01 25.28 na 9 14.66 25.15 na S15 11.0 K = K @ EQ01 28.47 na 16 11.0 30.9 na 11 14.66 29.78 na S1 9.0 K = K @ EQ01 21.74 na S2 8.91 K = K @ EQ01 23.55 na 1 14.66 22.43 na 2 14.08 24.91 na 4 14.08 25.02 na 6 14.08 25.22 na 8 14.08 26.13 na 10 14.08 27.78 na 12 14.08 30.4 na 13 14.08 59.92 na +FLO 0.0 66.37 na TEST 0.0 66.4 na The maximum velocity is 20.93 and it occurs in the pipe between nodes 12 and 13 22.6 23.89 23.03 23.43 24.14 23.33 23.5 22.6 23.57 22.99 23.97 23.68 24.69 26.2 22.89 23.83 295.0 250.0 0.2 113 7.0 Final Calculations - Hazen -Williams COSCO FIRE PROTECTION Page 6 SD6028-APPLE STORE SOUTHCENTER Date 082808 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes D001 22.60 1.049 1E 2.0 28.000 16.287 to 120 0.0 2.000 0.0 EQ01 22.6 0.1631 0.0 30.000 4.894 K Factor = 5.60 Vel = 8.39 0.0 22.60 21.181 K Factor = 4.91 *P-6 S5 23.89 1.049 1T 5.0 3.910 23.664 to 120 0.0 5.000 -1.585 3 23.89 0.1807 0.0 8.910 1.610 K Factor @ node EQ01 Vel = 8.87 0.0 23.89 23.689 K Factor = 4.91 *P-9 S8 23.03 1.049 1T 5.0 9.000 22.004 to 120 0.0 5.000 -1.585 5 23.03 0.1690 0.0 14.000 2.366 K Factor @ node EQ01 Vel = 8.55 0.0 23.03 22.785 K Factor = 4.82 *P-12 S11 23.43 1.049 1T 5.0 9.000 22.771 to 120 0.0 5.000 -1.585 7 23.43 0.1744 0.0 14.000 2.442 K Factor @ node EQ01 Vel = 8.70 0.0 23.43 23.628 K Factor = 4.82 *P-15 S14 24.14 1.049 1T 5.0 9.000 24.159 to 120 0.0 5.000 -1.585 9 24.14 0.1842 0.0 14.000 2.579 K Factor @ node EQ01 Vel = 8.96 0.0 24.14 25.153 K Factor = 4.81 *P-18 S3 23.33 1.049 1T 5.0 8.290 22.581 to 120 0.0 5.000 -2.451 1 23.33 0.1731 0.0 13.290 2.300 K Factor @ node EQ01 Vel = 8.66 0.0 23.33 22.430 K Factor = 4.93 *P-21 S4 23.50 1.049 1T 5.0 8.580 22.893 to 120 0.0 5.000 -1.585 3 23.5 0.1753 0.0 13.580 2.381 K Factor @ node EQ01 Vel = 8.72 3 23.88 1.38 1T 6.0 0.410 23.689 to 120 0.0 6.000 0.251 4 47.38 0.1688 0.0 6.410 1.082 Vel = 10.16 0.0 47.38 25.022 K Factor = 9.47 *P-24 S6 22.60 1.049 0.0 11.330 21.181 to 120 0.0 0.0 0.0 S7 22.6 0.1632 0.0 11.330 1.849 K Factor @ node EQ01 Vel = 8.39 S7 23.57 1.38 1T 6.0 2.330 23.030 to 120 0.0 6.000 -1.585 5 46.17 0.1609 0.0 8.330 1.340 K Factor @ node EQ01 Vel = 9.90 5 23.03 1.38 1T 6.0 0.410 22.785 to 120 0.0 6.000 0.251 6 69.2 0.3401 0.0 6.410 2.180 Vel = 14.84 Iinal Calculations - Standard COSCO FIRE PROTECTION Page 7 SD6028-APPLE STORE SOUTHCENTER Date 082808 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes 0.0 69.20 25.216 K Factor = 13.78 *P-27 S9 22.99 1.049 0.0 11.330 21.922 to 120 0.0 0.0 0.0 S10 22.99 0.1684 0.0 11.330 1.908 K Factor @ node EQ01 Vel = 8.53 S10 23.97 1.38 1T 6.0 2.330 23.830 to 120 0.0 6.000 -1.585 7 46.96 0.1660 0.0 8.330 1.383 K Factor @ node EQ01 Vel = 10.07 7 23.44 1.38 1T 6.0 0.410 23.628 to 120 0.0 6.000 0.251 8 70.4 0.3512 0.0 6.410 2.251 Vel = 15.10 0.0 70.40 26.130 K Factor = 13.77 *P-30 S12 23.68 1.049 0.0 11.330 23.262 to 120 0.0 0.0 0.0 S13 23.68 0.1779 0.0 11.330 2.016 K Factor @ node EQ01 Vel = 8.79 S13 24.69 1.38 1T 6.0 2.330 25.278 to 120 0.0 6.000 -1.585 9 48.37 0.1753 0.0 8.330 1.460 K Factor @ node EQ01 Vel = 10.38 9 24.14 1.38 1T 6.0 0.410 25.153 to 120 0.0 6.000 0.251 10 72.51 0.3710 0.0 6.410 2.378 Vel = 15.55 0.0 72.51 27.782 K Factor = 13.76 *P-33 S15 26.20 1.049 0.0 11.330 28.470 to 120 0.0 ' 0.0 0.0 16 26.2 0.2145 0.0 11.330 2.430 K Factor @ node EQ01 Vel = 9.73 16 0.0 1.38 1T 6.0 2.330 30.900 to 120 0.0 6.000 -1.585 11 26.2 0.0563 0.0 8.330 0.469 Vel = 5.62 11 0.0 1.38 1T 6.0 0.410 29.784 to 120 0.0 6.000 0.251 12 26.2 0.0565 0.0 6.410 0.362 Vel = 5.62 0.0 26.20 30.397 K Factor = 4.75 *P-36 S1 22.89 1.049 0.0 10.620 21.737 to 120 0.0 0.0 0.039 S2 22.89 0.1671 0.0 10.620 1.775 K Factor @ node EQ01 Vel = 8.50 S2 23.83 1.38 1T 6.0 2.330 23.551 to 120 0.0 6.000 -2.490 1 46.72 0.1643 0.0 8.330 1.369 K Factor @ node EQ01 Vel = 10.02 1 23.34 1.38 1T 6.0 0.410 22.430 to 120 0.0 6.000 0.251 2 70.06 0.3480 0.0 6.410 2.231 Vel = 15.03 2 to 4 0.0 70.06 2.635 120 0.0149 0.0 0.0 0.0 7.370 0.0 7.370 24.912 0.0 0.110 Vel = 4.12 4 47.38 2.635 0.0 5.000 25.022 to 120 0.0 0.0 0.0 6 117.44 0.0388 0.0 5.000 0.194 Vel = 6.91 ' . . final Calculations - Standard COSCO FIRE PROTECTION Page 8 SD6028-APPLE STORE SOUTHCENTER Date 082808 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes 6 69.20 2.635 0.0 10.000 25.216 to 120 0.0 0.0 0.0 8 186.64 0.0914 0.0 10.000 0.914 Vel = 10.98 8 70.40 2.635 0.0 10.000 26.130 to 120 0.0 0.0 0.0 10 257.04 0.1652 0.0 10.000 1.652 Vel = 15.12 10 72.51 2.635 0.0 10.000 27.782 to 120 0.0 0.0 0.0 12 329.55 0.2615 0.0 10.000 2.615 Vel = 19.39 12 26.20 2.635 1T 16.474 81.500 30.397 to 120 0.0 16.474 0.0 13 355.75 0.3014 0.0 97.974 29.525 Vel = 20.93 13 0.0 8.249 1E 21.141 276.120 59.922 to 120 0.0 21.141 6.098 +FLO 355.75 0.0012 0.0 297.261 0.345 Vel = 2.14 +FLO 295.00 8.249 0.0 10.500 66.365 to 120 0.0 0.0 0.0 TEST 650.75 0.0035 0.0 10.500 0.037 Qa = 295.00 Vel = 3.91 250.00 Qa = 250.00 900.75 66.402 K Factor = 110.54 WSCM APPLE STORE 106 FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \UM 3ER SHEET TITLE FA -01 SYSTEIv I FOMATION/TYPICAL WRING AND MOUNTING DETAILS FA -02 SYSTEM CALCULATIONS (GENEAL), RISE SITE PLAN FA -03 FIRE ALARM SYSTEM FLOO PLAN SCOPE OF WORK ADDITIONAL MAG LOCK RELAY TO FIRE ALARM SYSTEM. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIAT❑R TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO 1#18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDIO TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO 4114 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.0. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END TYPICAL WIRING AND MOUNTING DETAILS 0 DATA OUT DATA IN 0 END OF LINE DEVICE SUPERVISED SWITCH 0 0 0 HTRI-R ()STATUS LED N.O. COM N.C. 0 0 0 //1/1 GROUND NOT SHIELD 7 FROM FACP 24 VDC DOOR MAG LOCK • 410 • • 410 DOOR MAG LOC • FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTFORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE -MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NEPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDU\IDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (-4 FT) WHERE THE CABLE IS INSTALLED Q QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL EX (EXISTING) XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY EX (EXISTING) PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP 1 HT -R RELAY INPUT INTERFACE MODULE HTRI-R SIEMENS 4S BOX VERIFY LOCATION IN FIELD 2(E) 1(E) 2(E) 7(E) 2(E) EX 1srI WITH RELAY EX (EXISTING) DUAL INPUT INTERFACE MODULE HTRI-R SIEMENS 4S DEEP VERIFY IN FIELD HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD Io< LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD 6 SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE DETECTOR ❑ EX (EXISTING) AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING LJC EX EX FIRE ALARM SPEAKER STROBE CEILING MOUNT) EXISTING IRE ALARM PEAKER STROBE WALL MOUNT) EXISTING) FIRE ALARM STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING ZH-MC-W SIEMENS 4S DEEP BOX 80" A.FE. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX CEILING W/ 1G RING L EX Y c FIRE ALARM TROBE WALL MOUNT) EXISTING FIRE ALARM SPEAKER (CEILING MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. IB3 wp FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD E l MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F,B.❑. F.B.❑. N/A VERIFY IN FIELD A.F,F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A 11/A N/ BLUE AS BUILT NOTES TO CAD N/A N/A r:, r 4 BUBBLE NOTES: ALL THE CLOUD AREA ARE THE ADDITIONAL SCOPE OF WORK. O Without Comments As Noted in Red G Per The Attached Letter -ase plans have been reviewed by The Tukwila Fire 'ention Bureau for :-nformance with current City ndards. Accep,= -,_ suriject to errors and - •- ijsslons wiltr1177777. _•-!•i,r)--•:)rize violations of adopted -- 'dards and ordi anc-: :-ne responsibility for the Guacy of des 3 ..._ .. r._,taiiy the designer. ditions, -evisions to these drawings after anis date will vc ci �i=: c:eptance =.nd will require a resubmIttai o; revised•i.yinos .c_r subsequent approval. Final acceptance StitsijtaCt ri-=-l. re;t and inspection by The Tukwila Fire Preventi;( Eh,eau. Date: /;-) --1 r'1 By: C acceptance ., 01. . 0 . Fire Permit Number To 011206- 75-4407 Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 REV. BY: 0 m DESCRIPTION SHOP DRAWINGS DATE 2aaaaa C0 0 T co co W �o O W �z Lifj W W= CL Q = 4 og SCALE: 1/8"=1' DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 1 1 /01 / 19 BACKROUND PLAN PROVIDED BY: .JOB NUMBER: 49194-1} SHEET FA -01 .6E r - Le CH. The: L._ 11 STARBUCKS SEATTLE MARINERS TEAM SHOP Ltj FRANK[...II\1 LL - VERIZON \ALRELESS w __Tr • 1". tf---L-,/ ij. ''•••• ELEC PACIFIC Q,UNpivEAF•;), THE V\ALKING CC). L 1100 H eoe r cti\IG1 AcS I 11'1151 SEPHORA NORTH F S,2V 75 C 75 C 75 [HALLMARK uJ11 :F- T -E RARE ROSE HOT TOPIC BUBBLE NOTES: ALL THE CLOUD AREA ARE THE ADDITIONAL SCOPE OF WORK. CINGULAR ir 0 m0 U) T -MOBILE BIT OF HAWAII !CORDON'S \ifvF- r MRS. FIELDS 11451 ELEC. 1.1 L CLAIRE'S JOURNEYS BASKIN ROBBINS I. MEN (r) 0 0 .115(Sisi Li 1155 SUNGLASS HUT 0 m 0 0 0 SYSTEM CALCULATIONS ENDLESS I 11\1r+OVA I Orii5. • • >_ - J CLI- • 0 T- r-) 0 Gq • CHCCO- LATE AR KITS CAMERA MOTHERHOOD MATER' PIERCING PAGODA LIDS THE CITY LJ ! J.C. GO 0 EL L.4 APPLE FACP ADD ONS DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: 0, ‘5 Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 AD2-P (E)1 0.0635 0.0635 0.064 0.064 HTR-R(N-1) ' - 1 ICP -B6 ---- COlig8bOs' - - -0.-o-obt--- --6.511 0.108 - a 1 . ZH-MC-CW©30CD 1.18 ell 1.11 0.142 0.142 0.005 (E) 2 219 438.000 ZH-MC-CW©110CD (E) 2 259 518.000 0.0731 Amps 0.127 Amps ZR -MC ©15CD Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC ©30CD 0.098 HCP Alarm Current Load: 0.127 Amps For 5 Minutes= 0.011 Amp -hours 0.03 Amps 956.84 Amps 25% Derating= 2.206 Amp -hours 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 956.84 Total System Current Load: For 5 Minutes= 2.206 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Amp -hours APPLE SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: 0, ‘5 Device Type Qty Amps Total Amps Total Main System Board (E) 1 0.03 0.03 0.030 0.030 ZH-MC-CW©15CD (E) 5 0.108 0.540 ZH-MC-CW©30CD (E) 1 0.142 0.142 ZH-MC-CW@75CD (E) 2 219 438.000 ZH-MC-CW©110CD (E) 2 259 518.000 ZR -MC ©15CD (E) 2 0.064 0.128 ZR -MC ©30CD 0.098 HCP 0.0015 0.03 Amps 956.84 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 956.84 Amps For 5 Minutes= 80.375 Amp -hours 25% Derating= 101.368 Amp -hours Total System Current Load: 101.368 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION h fl 1 0'JO r APPLE WESTFIELD SOUTHCENTER MALL SCALE 1132 2S,2V 2S,2V 2S,2V 2S,2V OL El 75 C 15 C -1:0L-S1 D 0 A BOX1 EX FACP - - - , 1 Notification Appliance Circuit Detail ! PROJECT: I WESTFIELD SOUTHCENTER MALL , . ,----------------- -------:------------- - i Panel APPLElSI , iWire Resistance 1.62 ' ! * i Date: I September 9, 2008 CURRENT TOTAL= i 793 , i ciRcumlsi QTY Device Type ;AlC arm urrent i AlTotal VVi arm re Size VVire Length Voltage at EOL ' CircuitTotal !1 (E) 4 iZH-MC ©15CD , 108i 432 Total Wire Resistance ( R i ) -" ii 0.451, , 1 „•_.._ , . _............___. ,.„ __ .. ..., i(E) 1421- 1 1 1ZH-MC @75CD 2191 219 ' Total Device Load, Amps (1) ! 0.791 0 I , i I 0 (Total Cct Load) 0 0 Voltage Drop ( E) 0.351 1 0 1 I 0 , EOL Voltage O , , 0 (20.4 - E) 0 1 (E= I * R) 0 lz-mc@15co 641 0' 0 ;Z-MC©30CD 981 01 DEVICES=16 TOTAL m A= I 793 12 138 20.04543384 Notification Appliance Circuit Detail 1 PROJECT: WESTFIELD SOUTHCENTER MALL 793 Panel: APPLE S2 Wire Resistance 1.62 - - - Date: Octoberl, 2008 CURRENT TOTAL= 754 CIRCUIT:1S1 QTY 1 ,ZH-MC ©15CD 0 ZH-MC ©30CD 2 ZH-MC ©110CD Device Type 0 0 0 0 • 0 2 0 Z-MC@15CD Z-MC©30CD DEVICES=I5 20.051 ,Alarm Current! Alarm Total Wire Size 1 Wire Length ! Voltage at EOL 1 CircuitTotal 1 1081 1081 1 1 !Total Wire Resistance ( R ) 1.61 1421 0 1 (WL*2)*(R/ft) , 2591 ' 518 , i Total Device Load, Amps (I) 0.75 0 (Total Cct Load) 0 IVoltage Drop ( E ) 1.21: 0 (E= I* R) 0 EOL Voltage 19.191 0' 1 (20.4 - E) 64! 128 981 0 TOTAL m A=1 754 12 497 19.18584888 754 RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m w DESCRIPTION SHOP DRAWINGS DATE 0, ‘5 2 <<<<< CC cr w z 0 z 0 -J 0 w (1) 'CALE: 1/8"=l' DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE:11/01/19 BACKROUND PLAN PROVIDED BY: .,JOB NUMBER:49194-1} SHEET FA -02 L 2IS F IF 15 C S1-211ODV S2 -18.96V FAC =J . / J 2S J NORTH ►'r► -c c4' T. U. e 5vtSS APPLE WESTFIELD SOUTHCENTER ALL SCALE 118':V FT,AG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATION SUBMITTAL FOR L❑CATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR. SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM, FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. FIELD VERIFY EXACT L❑CATION FOR HTRI—R TO RELEASE MAG LOCK (WITH OWNER SECURITY CONTRACTOR). BUBBLE NOTES: 0 Q ALL THE CLOUD AREA ARE THE ADDITIONAL SCOPE OF WORK. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved co 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m m DESCRIPTION SHOP DRAWINGS DATE 0, 0 2aaaaa 1� 1 Z CC 0 0 J O co co W CC J( O Wz 2 zz W I cc U O) < :D 0 1 w W EC T. l\ i 6ALE: 1/8"=1' DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 1 1 /01 /19 BACKROUND PLAN PROVIDED BY: JOB NUMBER:49194-1} 1 SHEET FA -03 • APPLE FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM I\FORMATIO\ FA -02 TYPICAL DETAILS - WRING AND MOU\TI(N G FA -03 FRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISE, SITE PLAN T Without Comment* As Noted In Red Per The Attached Letter 1 nese plans have been reviewed by The Tukwila Fire Prevention Bureau for confoi rnance with current city standards. Acceptance is »t.thi t to errors and omissions which do not autrtorize violations of adopted .stanaaras and orainances. The r•_: ponsibituy for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this acceptance Rnd will require a resubmittal of revised drawings, for subsequent approval. ,Final acceptance is subject to field test and inspection b‘ The Tukwila Fire Prevention Bureau. / Date: r'4 - (7 - OB By: f TUKWILA FIRE DEPARTME Pease call: 575.4407 and give this job No. -F-L151 :,cap' a,Lidress for shut. %.,ynn or r-ast:;ration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to thi✓ .inspector prior to coiomencFltient of Acceptance Tes',.:Tic4 of any Fire Alarm and Detection Systems. Failure of test wilt result in a Re -inspection Fee a! termination of the WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO#16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER 'IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 1 2 7 2 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD I o I� LINEAR BEAM I N SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD A SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT SMOKE p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING Ir IC FIRE ALARM SPEAKER STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM STROBE (CEILING MOUNT) ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING 4 C FIRE ALARM STROBE (WALL MOUNT) FIRE ALARM SPEAKER (CEILING MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM BIS STROBE WP (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.D. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.D.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I IAN DESCRIPTION SHOP DRAWINGS DATE 0 0 rn 2 CaCC( co co J c0 (1) Z W cc© W J zz rit Lim rig=Q iftC Q CC c,) CD CD co CALE: 1 /8"=1 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: .1OB NUMBER: SHEET i FA -01 J THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT IAB. SSE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL END DF LINE DEVICE(3,6K 1/4W) SUPERVISED SWITCH h v - O DUCT DETECTOR L❑CATION 1 GROUND 0 M 0 -0 10 © HTRI-R OSTATUS LED m N.0 r 0 COM (D 0 N.C. ( NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL O LABEL SCALE PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE (BACKGOUND MUSIC SHUTDOWN) + NOTE 1; VOLTAGE MAX. - CURRENT MAK- CONT. RES. MAX.- MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - OUTLET SAMPLING TUBE INLET SAMPLING—\ TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE j(+) STOP IF LAST DEVICE l(-) FROM XLS CONTROL PANEL OR {(+) PREVIOUS ADDRESSABLE DEVICE (-) END OF LINE DEVICE (3.6K 1/4V) RELAY CONTACTS (4.0A C_-125VAC) (4.0A @ 3OVDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 21 ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST 25 SEC. TO GUARANTEE DETECTION. 0 + 1001 TB1 ssoeea 123456 HCP TB2 0 0 65"43 21 O 1 A 0 � SUPERVISED._)f % SWITCH i GROUND / 0 © © HTRI-D OSTATUS LED 0 NOT USED CO 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL `"BE` SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC 1.1 Im U 0 0 PAD -3 0 00 O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - Tei 24K n + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE 0 END OF LINE DEVICE 3.6K 1/4W) NAC -4 NAC -3 NAC -2 NAC -1 UPERVISED WITCH NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE .r... DEVICE LOOP 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS �W► EOL • 0 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCAT NONE (+ FROM FACP ( 0 0 EARTH GROUND --)..(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE HORN STROBE I STROBE MIRING DIAGRAM LABEL SCALE SPEAKER STROBE OR STROBE ONLY R 0 O 0 HORN/STROBE 4S DEEP BOX I w/ 1-1/2" EXTENSION RING j(SPEAKER STROBE) 4S BOX (STROBE ONLY) WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE EEL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERrN TEMPERATURE: +32' F 0- C TO 100' F (35 C) HUMIDITY: 9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS USTED FOR AIR YOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR r DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL SEL SCALE ( ) DATA OUT > (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTI❑N BOX MOUNTED ON CEILING. FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT / / / / / 0 0 0 IL TO NEXT DEVICE —CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE co 0 co 0 rn J 1 �CALE: 1 /8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 9/08/08 BACKROUND PLAN PROVIDED BY: \OB NUMBER: (e SHEET FA -02 J 2S F S1=213:0-5VA—BOX FACP S2 -18.96V EXI j D 2S 7 2S i' LAG I\OTES: NORTH 26'-6" iio � ttc7 APPLE V ESTFIELD SOUTHCENTER MAIL StA SCALE 118"=1 2S 110 26'-6 lyr 11� L. FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACT❑R, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I z DESCRIPTION SHOP DRAWINGS DATE 9/08/08 oa\a\a CALE: 1/8" =1 ' 1 DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: �OB NUMBER: SHEET FA -03} 0U-) Cfsi 0 0 N J Q W _ 0 Le CHATEL STARBUCKS SEATTLE MARINERS TRAM SHOP u 0 w 0 w VERIZON 1, Wi ELESS (f FOOTACTIC ACTIO HALLMARK (n /H. €uTI VA TF �- LLULA,R THE RARE ROSE THE LOCKER ROOM U 0 0 0 CINCUL AR 0 U (f) 0x z0 <m 0 U_ z (1) I, i11 1 ii >- =z < U-� T -MOBILE k,BIT OF 1, HAWAII J J 0 ID m fy !GORDON'S zl JEWELERS 0 1 T 0 MRS. FIELDS CTRASJ ELEC i PACIFIC SUNWEAR WEAR Nim a l 04k I g MOM OMNI MOM r iiiirii ii iii Via mom a n iuP CLAIRE'S JOURNEYS BASKIN ROBBINS THE 'r4ALKIIsiG CO. 1100 bebe 11101 SUNGLASS HUT 11 1115 SEPH0RA I 1 ^')n SWAROVSKI NORTH PINK BANANA REPUBLIC SKETCHERS 114011 APPLE WESTFIELD SOUTHCENTER MAGI > ry 0 1145 s Cr) 0 0 z 1 1155 ? 1�_ z 0 0 SUNGLASS HUT r -i LJ r� LJ I- -1 LJ r� LJ ry < Ld w (I) m 0 0 L,J J f--- 0 (I)0 ID J 1 0 BOMBAY CO. ENDLE I NIO\/A KITS CAMERA >-0 0 0 0= MU) MOTHERHOOD f` ATERN PIERCING PAGODA LIDS SPECS IN C f,i1\NK THE CITY LJ Cf TRASH CHAMPS SPORTS Y SYSTEM CALCULATIONS w O BATTERY SIZING CALCULATION m 0 J 1006 SCALE 1132 2S 2S 2S 2S 1:, 110 110 15 15 15 2S 2S 2S 2S 2S 2S 15 15 75 15 C 15 C 30 EOL -S1 EX EOL -S2 n,ID 2I APPLE APPLE FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations PROJECT: WESTFIELD SOUTHCENTER MALL Panel: =APPLE S1 ;Wire Resistance 1.62 Date: ;September 9, 2008 i CURRENT TOTAL= 793 « Current Load: CIRCUIT: S1 Standby: Alarm: Current Load: _ _ Standby: Type }__...__.._._.•._._._-_-_-_-_---._._ Alarm: Alarm Total 1 Wire Size Wire Length Voltage at EOL Circuit Total 4 15CD C 1ZH-M _-_---� 108. 432, I Total Wire Resistance (R) 1 0.45 1 1ZH-MC @30CD I 142 Device Type 1 Qty Amps Total Amps Total 1ZH-MC @75CD Device Type 219` Qty Amps Total Amps Total HFP-11 0 0.0022 0.0022 0.0023 01 [ Voltage Drop ( E) ; 0.35 0 AD2-P 1 0.0635 0.0635 0.064 0.064 0__ Main System Board 1 1 0.03 EOL Voltage 1 0.03 0.030 0.030 0 HTR -R 2 0.009600 0.0096 0.021 0.042 ZH-MC-CW @15CD - 5 0 Z-MC@30CD 98 0' r 0.108 0.540 HTRI-D i -_.----xzz::i __ - _mA= 0.001600 0.0035 DEVICES=,6 TOTAL 7931 12 138 1 20.04543384 ZH-MC-CW @30CD 1 0.142 0.142 ICP -B6 Notification Appliance Circuit Detail 0.005 1 PROJECT: WESTFIELD SOUTHCENTER MALL ZH-MC-CW@75CD 2 APPLE S2 ;Wire Resistance 1.62 219 438.000 CURRENT TOTAL= 754 CIRCUIT: S1 ZH-MC-CW @110CD 2 QTY Device Type 259 518.000 Wire Length 1 Voltage at EOL Circuit Total - 1 ZH-MC @15CD 108 1081 1 Total Wire Resistance (R ) -� 1.61 0 ZH-MC @30CD _ 142 0 ( 2 ZH-MC @110CD 259 5181 Total Device Load, Amps (I) i 0.75 001 � _ ____ _ �� ___ 0.0731 Amps 0.106 Amps 0 01 Voltage Drop (E) 1 1.21 ZR -MC @15CD I 2 0.064 0.128 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 2 Z-MC@15CD 0.098 1281 0 Z-MC@30CD 98 0k 1 HCP 1 r 1 1i f 0.0015 Alarm Current Load: TOTAL mA= 0.106 Amps For 5 Minutes= 0.009 Amp -hours --- 0.03 Amps 956.84 Amps _ 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 956.84 Amps For 5 Minutes= 80.375 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 101.368 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 101.368 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION m 0 J 1006 SCALE 1132 2S 2S 2S 2S 1:, 110 110 15 15 15 2S 2S 2S 2S 2S 2S 15 15 75 15 C 15 C 30 EOL -S1 EX EOL -S2 n,ID 2I 1743 FAX (206) 628-4990 TEL. (206) 622-65/45 RELEASE/REVISIONS REV. BY: I z a Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: =APPLE S1 ;Wire Resistance 1.62 Date: ;September 9, 2008 i CURRENT TOTAL= 793 « CIRCUIT: S1 _ _ QTYDevice --•_._-._- _._.__ ..__ Type }__...__.._._.•._._._-_-_-_-_---._._ Alarm Current Alarm Total 1 Wire Size Wire Length Voltage at EOL Circuit Total 4 15CD C 1ZH-M _-_---� 108. 432, I Total Wire Resistance (R) 1 0.45 1 1ZH-MC @30CD I 142 142' 1 (WL * 2 )* (R/ft) 1 1 1ZH-MC @75CD i 219 219` Total Device Load, Amps (I) 1 0.79 i 0 (Total Cct Load) 01 [ Voltage Drop ( E) ; 0.35 0 0 0__ 1 0 1 EOL Voltage 1 20.05 0 0 (20.4 - E) 0 1Z -MC _Y.@15CD 64 0 _�_.._.___.._-_.--- , - 0 Z-MC@30CD 98 0' r i -_.----xzz::i __ - _mA= DEVICES=,6 TOTAL 7931 12 138 1 20.04543384 793 Notification Appliance Circuit Detail 1 PROJECT: WESTFIELD SOUTHCENTER MALL Panel: APPLE S2 ;Wire Resistance 1.62 Date: October 1, 2008 CURRENT TOTAL= 754 CIRCUIT: S1 ____--_____; ____________- QTY Device Type Alarm Current Alarm Total 1 Wire Size Wire Length 1 Voltage at EOL Circuit Total - 1 ZH-MC @15CD 108 1081 1 Total Wire Resistance (R ) -� 1.61 0 ZH-MC @30CD _ 142 0 ( 2 ZH-MC @110CD 259 5181 Total Device Load, Amps (I) i 0.75 001 � _ ____ _ �� ___ s (Total Cct Load) 0 01 Voltage Drop (E) 1 1.21 I EOL Voltage - 19.19 001 (20.4-E) 2 Z-MC@15CD 64 1281 0 Z-MC@30CD 98 0k 1 1 r 1 1i f . DEVICES=5 TOTAL mA= 7541 12 497 19.18584888. 754 - i 1743 FAX (206) 628-4990 TEL. (206) 622-65/45 RELEASE/REVISIONS REV. BY: I z a DESCRIPTION SHOP DRAWINGS DATE CO 0 co 0 rn I « 0 w c w C1) w cC rr w z LU z d P - w C/) cn 6ALE: 1/8" =1 ' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 9/08/08 BACKROUND PLAN PROVIDED BY: �OB NUMBER: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -04 UiS0h FILE COSY APPLE FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WRI\G AND MOUNTING FA -03 FIRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIO\S (GENERAL), RISE, SITE PLAN TUKWILA FIRE -DEPARTMENT. Please call: 575-440Z and give this job and exact address for shut, bun or restoration approval, WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDIO TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 1 2 7 2 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD ISN LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE ®D DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE F C (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM STROBE (CEILING MOUNT) ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM © STROBE (WALL MOUNT) FIRE ALARM SPEAKER (CEILING MOUNT) Q C ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.0.N. SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING r-oWP FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD ❑M MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.D.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z 4 DESCRIPTION SHOP DRAWINGS DATE co 0 co 0 rn 2CCCCC 1 0 co 2 co J '- J C° <0.) CCW , .O w 63 W~ 1/45 0 J Zz 0- cc IL Q_gI< < < F3- Z CC OJ o c0 = I2- W } N CALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 9/08/08 BACKROUND PLAN PROVIDED BY: SOB NUMBER: SHEET k FA -01 J THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL Sri COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC 0 DUCT DETECTOR LOCATION END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH 1. 1 0 CN r7 m GROUND Lc) HTRI-R OSTATUS LED Co 0 N.O. r -- 0 1 N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL 0 `L SCALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLEC DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX. - CURRENT MAK-- CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - OUTLET SAMPLING TUBE INLET SAMPLING—� TUBE \ AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE f (.F) STOP IF LAST DEVICE l(-) FROM XLS CONTROL PANEL OR �(+) PREVI❑US ADDRESSABLE DEVICE (-) RELAY CONTACTS (4.0A @ 125VAC) (4.OA @ 30VDC) 27 VDC 3.5 mA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. + 10 01 TB1 56009 123456 HCP TB2 0 0 65 4321 O 0 END OF LINE 1 DEVICE �T SUPERVISETI SWITCH % GROUND (3.6K 1/4W) 0 0 0 10 HTRI-D OSTATUS LED 0 NOT USED CO 0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL " L scAl (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC in ta I T 0T El 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - $ o] Co *ll 24K TYPICAL V\1IRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE 2 NAC -4 NAC -3 ?NAC -2 ?NAC -1 END OF LINE DEVICE 3.6K 1/4W) SUPERVISED SWITCH FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0- 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS EOL 0 O (NPU (+ TM -1 Q • 0 0 -1-2-3 4 5 e TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL 0 0 EARTH GROUND .-)(+)TO NEXT DEVICE OR >.(-) STOP IF LAST DEVICE HORN STROBE 1 STROBE WIRING DIAGRAM LABEL SCALE SPEAKER STROBE OR STROBE ONLY R E 0 ! 45 DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) HORN/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE E❑L NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER11N TEMPERATU� E: +32' F (0' C) TO 100" F (338' C) HUMIDITY: O-933333% RELATIVE HUMIDITY, NON -CONDENSING HEP -11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOaTY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION 'NTH DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 J STANDARD / SMOKE DETECTOR BASE HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID —\ CEILING / SPEAKER SUPPORT TILE BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTI❑N BOX--\ MOUNTED ON \ CEILING, FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT / / / / / / / O O O O 1 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE \--SUSPENDED ILLUMINATED CEILING DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z Q DESCRIPTION SHOP DRAWINGS DATE co 0 co 0 rn 2 CCCCC z z 0 z z (/1 —J 7Itt. 0 J CALE:1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: `JOB NUMBER: SHEET J FA -02,, 1 1 1 LNL 5 D,I 2I 15 S1 -20.05V S2 -18.96V FACP rLac NOTS: 26'-6" 110 1i NORTH 2S VL_ 110 26'-6" APPLE WESTFIELD SOUTHCENTER MALL SCALE 118"=1' FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS,(SEE SIEMENS INSTALLATION SUBMITTAL FOR L❑CATI❑N GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACT❑R, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLATOR FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF C❑NTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE P❑WER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE co 0 03 0 rn 2 aC\\a 6ALE: 1/8"=1' u. DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: ,JOB NUMBER: SHEET FA -03 STARBUCKS SEATTLE MARINERS TEAM SHOP J FO0TA0TI0N MARK'S HALLMARK THE LOCKER ROOM VRaZON ATIVATER THE RARE ROSE WIRELESS C LLULA FRANKLIN COVEY w TRASHI 9 ELEC r 0 L� J -)Et4 PACIFIC SUNWEAR ABERCROMBIE & FITCH THE \ALKING CO. [1100 bebe 1110 SUNGLASS HUT 111151 SEPHORA SWAROVSKI NORTH PINK HOT TOPIC CINGULAR BANANA REPUBLIC BROOKSTONE LL 0 a O a 0 Qw N_ GADZOOKS Ct 1.L1 1.1J U z <0 Q 0 -_JJ W 0 5 BIT OF HAWAII GORDON'S JEWELERS SKETCHERS 111401 APPLE WESTFIELD SOUTHCENTER MALL N w w cc 0 LL 1145 MRS. FIELDS CLAIRE'S JOURNEYS BASKIN ROBBINS MEN ZALES JEWELER SUNGLASS HUT 1--I LJ r-, LJ ri LJ r-1 LJ CHOCO- LATE 0 0 laJ __J 0 O 0 BOMBAY CO. ENDLE INNUUVA KITS CAMERA >-cL 00 o= COM MOTHERHOOD MATERN11 PIERCING PAGODA LIDS J �n 0 z w 1--- 1155 SPECS IN THE CITY p CHAMPS SPORTS Y SYSTEM CALCULATIONS z W BATTERY SIZING CALCULATION 0------', 'S I , X J ' \ - ' - -- -,--3-5.r----- - - LOVE CULTURE 1006 SCALE 1132 2S 2S 2S 2S 110 2S 110 2S a va 15 2S 15 2S F 15 2S 15 15 75 15 C 15 C 30 0 EOL -S1 2S 2S FA -BOX EX FACP 0 EOL -S2 D,ID 2I APPLE APPLE 1.62 793 FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations - PROJECT: WESTFIELD SOUTHCENTER Panel: APPLE Si !Wire Resistance October 1, 2008 CURRENT TOTAL= Date: September 9, 2008 CURRENT TOTAL= Current Load: S1 Standby: s Alarm: Alarm Current Current Load: Wire Length 1 Voltage at EOL Circuit Total _i y Standby: Alarm: Device Type Alarm Current Alarm Total 1 Wire Size Wire Length Voltage at EOL Circuit Total 0 142 259 4 ZH-MC ©15CD 108 4321 142 (WL* 2 ) * (R/ft) - � �__ -_ _ Total Device Load, Amps (I) I 0.75 2 1 Device Type s 01 Qty Amps Total Amps Total 1 Device Type 219 Qty Amps Total Amps Total HFP-11 !-^ 0.79 0.0022 0.0022 0.0023 0; 0 0 04 0 _ (20.4 - E) Voltage Drop (E )'� _____�___0.350 AD2-P 64 1 0.0635 0.0635 0.064 0.064 0 Main System Board 98 1 0.03 0.03 0.030 0.030 HTR -R DEVICES= 2 0.009600 0.0096 0.021 0.042 ZH-MC-CW @15CD 5 0.108 0.540 0 HTRI-D 64 0;J 0.001600 0.0035 ZH-MC-CW @30CD - 1 Z-MC@30CD 98 01 0.142 0.142 ICP -B6 0.005 ZH-MC-CW @75CD 2 DEVICES= 219 438.000 793! 12 138 20.04543384 793 _ ZH-MC-CW @110CD 2 259 518.000 0.0731 Amps 0.106 Amps ZR -MC @ 15C D 2 0.064 0.128 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours _ZR -MC @30CD 0.098 HCP 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.03 Amps 956.84 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 956.84 Amps For 5 Minutes= 80.375 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 101.368 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 101.368 Amp -hours I Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION 0------', 'S I , X J ' \ - ' - -- -,--3-5.r----- - - LOVE CULTURE 1006 SCALE 1132 2S 2S 2S 2S 110 2S 110 2S a va 15 2S 15 2S F 15 2S 15 15 75 15 C 15 C 30 0 EOL -S1 2S 2S FA -BOX EX FACP 0 EOL -S2 D,ID 2I 1743 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 w w w J W REV. BY: Notification Appliance 1 Notification Appliance Circuit Detail MALL 1 J 1.62 793 1 - PROJECT: WESTFIELD SOUTHCENTER Panel: APPLE Si !Wire Resistance October 1, 2008 CURRENT TOTAL= Date: September 9, 2008 CURRENT TOTAL= CIRCUIT: S1 QTY Device Type Alarm Current Alarm Total 1 Wire Size Wire Length 1 Voltage at EOL Circuit Total _i y �� QTY Device Type Alarm Current Alarm Total 1 Wire Size Wire Length Voltage at EOL Circuit Total 0 142 259 4 ZH-MC ©15CD 108 4321 142 (WL* 2 ) * (R/ft) - � �__ -_ _ Total Device Load, Amps (I) I 0.75 2 1 s 01 Total Wire Resistance (R) 0.45_ 1 ZH-MC @30CD 142 1 ZH-MC ©75CD 219 2194Total Voltage Drop (E) I 1.21 (E= I* R) 0 Device Load, Amps (I) (Total Cct_Load) !-^ 0.79 o 1 0; 0 0 04 0 _ (20.4 - E) Voltage Drop (E )'� _____�___0.350 Z-MC@15CD 64 128 -{ 0 Z-MC@30CD 98 _ 01 DEVICES= 5 EOL Voltage 20.05 o 754 0 (20.4 - E) i 1 0 Z-MC©15CD 64 0;J 1 - 0 Z-MC@30CD 98 01 DEVICES= 6 TOTAL mA= 793! 12 138 20.04543384 793 _ 1743 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 w w w J W REV. BY: Notification Appliance Circuit Detail I 4 4 1.62 754 I PROJECT: WESTFIELD SOUTHCENTER MALL Panel: APPLE S2 (Wire Resistance DATE Date: October 1, 2008 CURRENT TOTAL= CIRCUIT: S1 QTY Device Type Alarm Current Alarm Total 1 Wire Size Wire Length 1 Voltage at EOL Circuit Total �� 1 ZH-MC @15CD 108 108 Total Wire Resistance (R) J T 1.61 0 ZH-MC ©30CD ZH-MC 11OCD @ 142 259 01 518' 1 ; (WL* 2 ) * (R/ft) - � �__ -_ _ Total Device Load, Amps (I) I 0.75 2 0 s 01 1 (Total Cct Load) 0 0i 01 Voltage Drop (E) I 1.21 (E= I* R) 0 0 _ 01 1 EOL Voltage t 19.19 0 0 _ (20.4 - E) 2 Z-MC@15CD 64 128 -{ 0 Z-MC@30CD 98 01 I DEVICES= 5 TOTAL mA= 7541 2 497 19.18584888 754 1 1 , 1743 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 w w w J W REV. BY: z 4 DESCRIPTION SHOP DRAWINGS DATE co 0 c0 0 rn z <CCCC 0 w D C/) co EE co T �� J w � 0 CC � W cc CL w= W ize CD Q 1'S ITEs 1- 0 W t� V J �CALE: 1/8"=1 ' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 9/08/08 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ..JOB NUMBER: SHEET i FA -04 } FiLE COPY APPLE FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET NUM3ER SHEET TITLE SHEET INDEX FA -01 SYSTEIV INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISE, SITE PLAN 1 !nese plans have been reviewed by The Tukwila Fire Prevention Bureau for cor:ioi -n.,with current city L, standards. Acceptance is tc :,refs and E omissions wl-r ch do not aticns of adopted st'fl k.f,:!,. :., fbUi for the Addriticr:5, C'_.. :i t:. oi , :/::;i_.._ 6rav,ings atter this da_2 c u it =cc ;:�::;:;.,. .nCi wili require a resubmittal of revised'Lir a:':'(('ig far subsequent approval. Final acceptance is subject to field test and inspection b\ 1The Tukwila Fire Prevention Bureau. Date: /'��'7b By: �� I n Without Comments As Noted In Red Per The Attached Letter f UKWILA FIRE DEPARTM9EM. Please call: 575-4407 and give this job No. ON -F - LIS and exact address for shut' Iiu vn or restoration aooraval. 1 ri 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. 1 may"TfANT Buse of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you n ed to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inF 'tion. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIAT❑R TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART' NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NEPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED SYMBOLS LEGEND QUANTITY 2 1 6 4 2 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP ® INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD ID a LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP IN/ 1G RING CEILING ® DUCT SMOKE p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE MC (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM SPEAKER STROBE r (WALL MOUNT) FIRE ALARM STROBE C (CEILING MOUNT) ILI ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM STROBE (WALL MOUNT) FSIPEAARE LARM ST C (CEILING MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM B p STROBE WP (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD EU MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.❑. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAID 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NVI DESCRIPTION SHOP DRAWINGS DATE 9/08/08 2CCCCC 1 w Z 0 0 z SCALE: 1 /8”•=1' DRAWN BY: (.ANDERSON ESIGNED BY: .VEZZANI SEP 23 2Q0ly Tukwila Fire a,a7�..JOB NUMBER: Jf/57/ - SHEET FA -01 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved DATE:9/08/08 BACKROUND PLAN PROVIDED BY: THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR if PREVIOUS ADDRESSABLE DEVIL NW - 0 DUCT DETECTOR L❑CATION 1 0 END OF LINE DEVICE(3.6K 1/4W) 0T b 0 SUPERVISED SWITCH GROUND N) Lr) © HTRI—R STATUS LED 0 N.O. r -- (r) c,0 0 N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL O (ABELSCALE(BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX,— CURRENT MAX.— CONT. RES. MAX.— MAX. CABLE LENGTH— C (LINE TO LINE)— C <LINE TO SHIELD)— MAX. LINE SIZE— MIN. LINE SIZE— OUTLET SAMPLING TUBE INLET SAMPLINGS TUBE \ AT LEAST SIX DUCT WIDTHS FROM BEND 2 TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE f STOP IF LAST DEVICE 1(+) FROM XLS CONTROL PANEL DR PREVI❑US ADDRESSABLE DEVICE (-) END OF LINE DEVICE RELAY CONTACTS (4.OA @ 125VAC) <4.0A @ 30VDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. <18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. 7/ 0 J TB1 123456 HCP TB2 0 O 0 (3.6K 1/4W) i SUPERVISED SWITCH GROUND 0 r7 L(7 © HTRI—D OSTATUS LED r-- CO \ NOT USED (0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABELSCALE(FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC m Wed t7) TY r II 0 0 PAD -3 0 0 00 O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - glial -Q-1 u§11<aa Q. 24K n 1112 + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END DF LINE DEVICE 3,6K 1/4W) `-6UPERVISED WITCH NAC -4 NAC -3 NAC -2 ?NAC -1 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0- 0 0 {FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS EOL TSM —1 O >Ea zoo U Q J °,Ugco QSQ c QOO o • • • TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE 0 0 EARTH GROUND -).(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE HORN STROBE I STROBE WIRING DIAGRAM LABEL SCALE SPEAKER STROBE OR STROBE ONLY R 0 HORN/STROBE 1 4S DEEP BOX w/ 1-1/2" I EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE EDL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER�T1IN TEMPERA RE: +32' F (0' C) TO 100' F (38 C) HUMIDITY: 0-9333333% RELATIVE HUMIDITY, NON—CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT IN WHEN USED IN CONJUNCTION W1111 DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 STANDARD SMOKE DETECTOR BASE FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (—) >- DATA IN (+) > HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL sca1F CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID —\ CEILING SPEAKER SUPPORT TILE BRIDGE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT JUNCTION BOX \ MOUNTED ON CEILING FLEX SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE io / / / / 0 0 i n TO NEXT DEVICE 0 CADDY BAR \— SUSPENDED ILLUMINATED CEILING DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved CO 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I z d DESCRIPTION SHOP DRAWINGS I DATE 00 0 CO 0 rn 1/ 1 z z 0 0 z 0 z E 0) W �CALE: 1 /8"=1 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 1 r SHEET FA -02} LAG OTES: 51-20 05V S2 -18.96V pLi 30 Il FA—BOX Rl b "VISI D 15 D,I 2I FACP 1 2S c - 2S 2S PI --'15 I 1 .(2,- 2S 2S F 75 y 13 2S- 2S 75 ©C 7513 NORTH APPLE WESTFIELD SOUTHCENTER MALL SCALE 118"=1' FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATI❑N SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z d DESCRIPTION SHOP DRAWINGS DATE 00 0 co 0 0, 2Ca\\C / W uJ u. �CALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: _JOB NUMBER: i SHEET FA -03 J )) IL- \--4 WIZON WINELESS 1 0 LLI Z 0 0 -j- LJ n Le CHATEL ijij STARBUCKS SEATTLE MARINERS TEAM SHOP PACIFIC SUNWEAR ACTIVAL_F CILLLULAK RAVE GIRL THE WALKING CO. 1100 bebe SUNGLASS HUT SEPHORA 111151 I .1 1 r\ SWAROVSKI NORTH PI\IK Ji FOOTACTION USA THE RARE ROSE LL m bi m LJJbi u.) LLi< 0 _J J LOCKER ROOM HOT TOPIC (f) oc ZLd aT (f) < - LL! C INC U L AR Kfl I I -L Z I < (l) • • • • • T -MOBILE BIT OF HA\/AII enRDON'S JEWELERS M R S. FIELDS BASKIN ROBBINS _J CO 0 0._ w ft cn SKETCHERS APPLE WESTFIELD SOUTHCENTER MALL 1145 (7)9 sUNGLASS HUT F- -1 LJ I- -1 LI I- -I LJ L (1) 0 0 p 0 (f) 0 BOMBAY CO. ENDLE IN NOVA K I TS CAMERA C MOTHERHOOD MATERN PIERCING PAGODA LDS i SPECS IN l4iNt\i THE CITY L J I TRASH J. C . SYSTEM CALCULATIONS CHAMPS SPORTS 1 0 I 2 BATTERY SIZING CALCULATION 1 g\ 11150 LI1155 X Or--- -- I . . \ J 1 \ 1 _ LOVE CULTURE 10061 SCALE 1132 2S 2S 75 C 75 C 75 2S 2S 15 15 75 F 2S C 15 2S 15 2S 15 2S C 15 2S 15 2S C 30 2S Iva EOL -S1 2S FA -BOX EX fl DID 21 Notification Appliance Circuit Detail PROJECT: 'WESTFIELD SOUTHCENTER MALL Panel: APPLE S1 Date: CIRCUIT: QTY 4 iWire Resistance 1.62- i September 9, 2008 1 _ ! Device Type 'Alarm Current Alarm Total 1 Wire Size ZH-MC ©15CD . . 108 4321 1 IZH-MC ©30CD CURRENT TOTAL= 793 Wire Length Voltage at EOL Circuit Total 142 ©75CD ZH-MC 1 1 219 , 0 0 0 i 0 0 0 1421 2191 0 01 Total Wire Resistance ( R ) (WL*2 )*(R/ft) 0.45 Total Device Load, Amps (I) (Total Cct Load) 0.79 Voltage Drop ( E) 0.35 01 01 o o I Z-MC@15CD 64 0 IZ-MC©30CD 98 (E= I * R) EOL Voltage (20.4 - E) 20.05 ol DEV10ES=16 TOTALmA= 7931 12 138 20.04543384 793 APPLE APPLE Notification Appliance Circuit Detail FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS _ PROJECT: __ ___ WESTFIELD SOUTHCENTER Panel: APPLE SI MALL i 1.62 893 oo 0 co 0 .,. 0, 2 Wire Resistance <CC< Current Load: Date: September 9, 2008 CURRENT TOTAL= Standby: Alarm: Current Load: CIRCUIT'S1 1,. Standby: Alarm: .....__ CITY Device Type _jAlarm Current 108 Alarm Total 1 108 Wre Size Wire Length 1 Voltage at EOL Circuit Total 1ZH-MC ©15CD 1 1 Device Type Qty Amps Total Amps Total 0 'ZH-MC ©30CD Device Type 0 Qty Amps Total Amps Total HFP-11 219 6571 0.0022 0.0022 0.0023 Total Device Load, Amps (I) 0.89 7 0 0 1 AD2-P (Total Cct Load) 1 0.0635 0.0635 0.064 0.064 01 Main System Board 1 0.03 0.03 0.030 0.030 _._,..., HTR -R 0 2 0.009600 0.0096 0.021 0.042 1 ZH-MC-CW ©15CD ......_._ ,__............. 5 i 1 0.108 0.540 HTRI-D (20.4 - E) 0.001600 1281 0.0035 ZH-MC-CW @30CD 1 0 Z-MC@30CD 98 0 1 0.142 0.142 ICP -B6 0.005 1 ZH-MC-CW ©75CD 4 DEVICES=16 TOTAL m A= 219 876.000 893 0.0731 Amps 0.106 Amps ZR -MC @15CD 2 0.064 0.128 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 0.098 HCP 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.03 Amps 876.84 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 876.84 Amps For 5 Minutes= 73.655 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 92.968 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 92.968 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION 1 g\ 11150 LI1155 X Or--- -- I . . \ J 1 \ 1 _ LOVE CULTURE 10061 SCALE 1132 2S 2S 75 C 75 C 75 2S 2S 15 15 75 F 2S C 15 2S 15 2S 15 2S C 15 2S 15 2S C 30 2S Iva EOL -S1 2S FA -BOX EX fl DID 21 Notification Appliance Circuit Detail PROJECT: 'WESTFIELD SOUTHCENTER MALL Panel: APPLE S1 Date: CIRCUIT: QTY 4 iWire Resistance 1.62- i September 9, 2008 1 _ ! Device Type 'Alarm Current Alarm Total 1 Wire Size ZH-MC ©15CD . . 108 4321 1 IZH-MC ©30CD CURRENT TOTAL= 793 Wire Length Voltage at EOL Circuit Total 142 ©75CD ZH-MC 1 1 219 , 0 0 0 i 0 0 0 1421 2191 0 01 Total Wire Resistance ( R ) (WL*2 )*(R/ft) 0.45 Total Device Load, Amps (I) (Total Cct Load) 0.79 Voltage Drop ( E) 0.35 01 01 o o I Z-MC@15CD 64 0 IZ-MC©30CD 98 (E= I * R) EOL Voltage (20.4 - E) 20.05 ol DEV10ES=16 TOTALmA= 7931 12 138 20.04543384 793 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: . Notification Appliance Circuit Detail DESCRIPTION SHOP DRAWINGS _ PROJECT: __ ___ WESTFIELD SOUTHCENTER Panel: APPLE SI MALL i 1.62 893 oo 0 co 0 .,. 0, 2 Wire Resistance <CC< Date: September 9, 2008 CURRENT TOTAL= CIRCUIT'S1 1,. i , 1 .....__ CITY Device Type _jAlarm Current 108 Alarm Total 1 108 Wre Size Wire Length 1 Voltage at EOL Circuit Total 1ZH-MC ©15CD 1 1 Total Wire Resistance ( R ) 1.61 0 'ZH-MC ©30CD 1 142 0 ( WL * 2 )* (Rift) 3 ZH-MC ©75CD 219 6571 Total Device Load, Amps (I) 0.89 7 0 0 1 (Total Cct Load) 0 : 01 Voltage Drop ( E ) 1.44 0 _ ...,.. _ _ 0 0 2 Z-MC@15CD _._,..., 0 . (E= I * R) 1 ......_._ ,__............. ...._... 0 01 i 1 EOL Voltage 18.96 (20.4 - E) 64 1281 i 1 0 Z-MC@30CD 98 0 1 -7.--- 1 DEVICES=16 TOTAL m A= 8931 1 12 497 18.96201996 893 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS Li.] 1- < cn oo 0 co 0 .,. 0, 2 < <CC< r -Th 0 1.1J F- E) cE C/3 cc (1) 0 cit) (S -ALE: 1/8"=l' DRAWN BY: 'ANDERSON DESIGNED BY: R.VEZZANI DATE:9/08/08 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ,JOB NUMBER: SHEET FA -04 — I IX 2 EMOVE CAPS AND INSTALL RED COUPLING NOTICE Weld stamps must be inspected before pipe is hung. p_g_Liot paint piping prior to hydrostatic test t'UKWILA FIRE DEPARTME t Please call: 575-440Z and give this job _s_ `'l s Lj Amer' No. 02 and exact address for shuts Town or rsstoration approval, Without Comments As Noted In Red .K Per The Attached Letl+r 1 nese plans have been reviewed by The Tukwila Fire Prevention Bureau for COr;t .rrl,anu�e W;t,T current city standards. Accepterce is , t to ;:.rrcrs and omissions- ; h,'t'ii do not of adopted .. t...:y,w'�^ .�-n: for the .LC:Lh:r i3, It O_ .;_: ola 4rg$atter vi -Fd ii,; . ...., _;r; = n' •:viii require a r e_ubrlittai of revised ara,.i.ings for subsequent approval • Final ecc ptcnce it subject to Feld test and inspection b‘ The Tukwila Fire Prevention Bureau. [Date: 9- /C --O g By: fl a -s . spy-a�vmm..w.R� •+ 3 -3w0 -111k r -r -41-8 EE14' 2-3 O 14p 6 — A-8 LOWER MAIN r- ELEVATION REVISI❑N PER 3rd PARTY REVIEW * HYDRAULICI NODES SHOWN I 35 10'-0' 4 2Y' 5-11 _040, --„,;'- a 2'¢' 0 5-5 �. 1 a' 4� d- 5g, `� 02 + ' 2!�' 5-1 iiiV 1 prL prL I s prL * 1 ' 4 0 1-1.11-4z, L 1, o* 1 �.* :. 0 23? 5-0 •02 1 1 02 o s O'L 1 o`L . .-"/44N 1 02 ;4# s s o2 c lis A —,/ s a 0� v 6 1 prL o 0' ,,.$ 2#. d 8-1 u,ru 1 p2 2#' 4-11 . -'4430' 1 �� 21<Z' 5-7 n' p2 1 i 55. Z 0. 1,P �� 2Y�' 6-1 p,L a 2%' 3-11J a'}}(�{, fl3 -6 I 1 2l¢' �r 6-7 �,L -�� r p2 4 p', 1 3-5• �. •- 1 4- v ' 2 ' � 7-1 p2, 1 I F•}�1�+' 2-tt Si. �h .'t• o i -7 p2 rY 2 . •, . o c -7 1 4 4�21�' x,14 'CSS #� v p� o 16 1 --.-./1.----- .44).1'p9/ 1 117-0' 02 S13 I I 1 r� 0D1 I It,� ' 1 `1 , 02 ,- 1 X02 T 4 S6 s —co x' 02 54 1 , 02 tt 1 , o 0 I — 1 1 1v' p� 1 o'L 11'-0) 1 �, 4 p2 1 �,� � OZ, / 14 1 ®, o`L 1 S9 1 cg, 1 1 & a 4 S12 ¥ 1-)I r _. 1 o'L . o cu 011ft . o 2 C 2' C 2' ~ 8_i ail 6-i (1J M 1' c,) GENERAL NOTES UI NODES AT RISER (SEE CALCULATIONS) '4 OTA T NOTICE Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Tho. fore, you will ne;d to call 205-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. 2. 3, 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. DES,,,WLANDAgS,LALLATION SHALL CONFORM TO NFPA PAMPHLET 13 (2007 ed.) AND ALL 1 CITY OF TUKWILAi REQUIREMENTS. ALL MATERIALS SHALL BE NEW AND U.L. APPROVED. PIPE: ALL PIPE 2' AND SMALLER TO BE SCHEDULE 40 BLACK STEEL. ALL PIPE 2' AND LARGER TO BE SCHEDULE 10 BLACK STEEL. FITTINGS: ALL FITTINGS (SCREWED AND GROOVED) AND GROOVED COUPLINGS TO BE STAR BRAND DUCTILE IRON. PAINTING OF PIPE AND PROTECTION OF SPRINKLER HEADS FROM PAINT IS BY OTHERS. ALL ELECTRICAL WIRING AND C❑NDIUT IS BY OTHERS. ALL WELDING TO CONFORM WITH AWS D10.9 AND WILL BE PERFORMED IN C❑SC❑'S SHOP, IT IS THE BUILDING OWNERS RESPONSIBILITY TO KEEP ALL AREAS WITH WET SPRINKLER SYSTEMS HEATED TO A MINIMUM 40 DEGREES FAHRENHEIT TO PREVENT FREEZING OF PIPES, OWNER IS RESPONSIBLE TO ASSURE THAT STRUCTURE AS IT IS SHOWN ON THE CONTRACT DRAWINGS CAN ADEQUATELY SUPPORT ALL FIRE SPRINKLER PIPING LOADS, NO AUXILLIARY DEVICES OR ATTACHMENTS SHALL BE PROVIDED BY CUSCO TO SUPPLIMENT THE STRUCTURE TO ACCOMODATE FIRE SPRINKLER PIPING LOADS. COSCO ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE DR CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIED OR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY CUSCO FIRE PROTECTION. UNDERGROUND CONTRACTOR SHALL FLUSH THE UNDERGROUND AND PR❑VIDE COSCO WITH THE PROPER CERTIFICATE OF DOING S❑ BEFORE COSCO WILL CONNECT TO THE UNDERGROUND PIPE. SPRINKLER HEADS ARE DESIGNED TO BE IN CENTERLINE OF CEILING TILE (+/— 1'). ALL DIMENSI❑NS ARE TO CENTERLINE OF PIPE. REVISIONS NO. DESCRIPTION DATE BY 0 SUBMITTAL TO TUAZON ENGINEERING -3RD PARTY APPROVAL 09-02-08 T.N.R. SUBMITTAL TO CITY OF TUKWILA 09-09-08 T.N.R. SPRINKLER HEAD LEGEND : SYMBOL SIN 3/8' C -CLAMP WITH 10' RETAINING STRAP HYDRAULIC DESIGN -REMOTE AREA APPLE—MOST REMOTE 1500 ft2 ORDINARY HAZARD GROUP 2 .20 GPM/1500 S.F. K=5.6 130 S.F. MAX. PER HEAD 15 SPRINKLERS IN REMOTE AREA SPRINKLER DEMAND: 650.75 GPM @ 66.402 PSI ADDED HOSE STREAM: 250 GPM TOTAL SYSTEM DEMAND: 900.75 GPM @ 66.402PS ARGCO #3B OFFSET WHERE LENGTH OF ALL THREAD ROD EXCEEDS 1'-10' ADD SECOND RESTRAINT ORIFICE TOLCO FIG. 65 C -CLAMP PIPE ROD SIZE DIA 1” 3/8" 11/4" 3/8" 1 1/2" 3/8" 2" 3/8" 2 1/2" 3/8" 3" 3/8" 4" 3/8" 6" 1/2" 8" 1/2" RETAINER STRAP, NUT THREADED ROD HILTI FIG LH 0R TOLCO FIG 200 HANGER RING UL 04/2007 COSCO STANDARD HANGER #2 I' ALL THREAD ROD TRAPEZE ASSEMBLY 3/8' C -CLAMP WITH 10' RETAINING STRAP 3/8'x6' ALL THREAD ROD 3/8' ALL THREAD ROD WELDED TO END OF PIPE (NTS) SYMBOL = TRPZ EXISTING BRANCHJNE +15-T AFF EE PLAN FOR LENGTH 6'-0"'FLEXHEAD" FLEXIBLE DROP CORRUGATED STAINLESS STEEL BRAIDED HOSE STRECHED MEMBRANE PANEL +11'-0" AFF 4" C -CHANNEL ACOUSTICAL PANEL +l 1'-0" AFF 7 WIDE STAINLESS STEEL CEIUNG TROUGH TYPICAL ARMOVER TO NEW SPRINKLER HEAD (N.T.s.) 3/8 X 3-1/2 LAG SCREW FOR WOOD 3/8' KWIK BOLT FOR CONCRETE . 1/4 X 1 TEK FOR BARJOIST OR STEEL BEAM 3/8'x1-10 ALL THREAD ROD MAX PER SINGLE RESTRAINT HANGER RING (UP TO 2' PIPE) LINE RESTRAINT DETAIL NOTE: 1) SPACE WITH IN 6" OF A HANGER EVERY 42'-0", 2) BRACING PER NFPA-13(2007 ed.) SECTIONS 9.3.5.8.8, TABLE 9.3.5.8,8(c) AND 9.3.6—RESTAINT OF BRANCH LINES NPT K•FACT. HEAD FINISH PLATE FINISH TEMP. QUAN. Victaulic Model V27 SSP on Flex Drop V2707 1/2" 1/2" 5.6 CH CH 155° 47 Reliable Model FT SSU on Sprig -up R1725 1/2" 1/7 5.6 BR N/A 200° 15 APPROVALS BY: CITY OF TUKWILA TOTAL SPRINKLERS THIS SHEET 62 • 000006. • 0 o 0 00. •6 • 4 0 • • • Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS WASHINGTON OFFICE 15000 Woodinville -Redmond Rd NE Woodinville, Washington 98072 call (425) 686-8300 • fax (425) 827-4784 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE • ANCHORAGE www.coscofire.com License No: COSCOFP110NM FILE COPY ATTACH TO BOTTOM OF ROOF DECK WITH TOLCO FIG. 78 THREADED STEEL DECK PLATE (2)-1/4" X I" TEK SHEET METAL SCREW PIPE SIZE I I1/4" 1 1/2" 2" ROD DIA 3/8" 3/8" 3/8" 3/8" THREADED ROD TOLCO FIG 200 HANGER RING 04/2007 COSCO STANDARD HANGER #8 METAL TOLCO FIG. 25 SURGE RESTRAINER TYPE 1 — FOR 1" AND 1-1/4" PIPE AND HANGER TYPE 2 — FOR 1-1/2" AND 2" PIPE AND HANGER STATIC PRESSSURE IN EXISTING SYSTEM EXCEEDS 100 PSI. SURGE RESTAINT IS REQUIRE ON ALL HANGERS SUPPORTING PIPE 12" AND LONGER (NFPA 13 2007 ED.) SURGE RESTRAINT #25 TOLCO FIG. 800 SWAY BRACE ATTACHMENT STEEL I -BEAM FIG. 980 SWIVEL SWAY BRACE FITTING 1' SCH.40 PIPE _FIG. 1001 "FAST CLAMP" SWAY BRACE ATTACHMENT SWAY BRACE ATTACHMENT TO STEEL I—BEAM SHOWN IN LATERAL BRACE APPLICATION SYMBOL= VICINITY MAP APPLE STORE -SOUTHCENTER 84-518'SOUTHCENTER MALL TUKWILA, WA. 98188 PAID SEP 1 1 2008 LOCATION OF STORE N Tukwila Fire 74,26fh CONTRACT Mt SHAWMUT DESIGN AND CONSTRUCTION 560 HARRISON AVENUE BOSTON, MA. 02118 DRAWING TITLE FIRE SPRINKLER TENANT IMPROVEMENT DATE : 8-25-08 SCALE : 1/8" = 1'-0" DRAWN BY : T.N.RHODES 5S D6028 SHEET NO. FS -1 ARAG IRE ARM SYSTEM ADDITION UKWILA, WASHINGTON HJithout COrflinent5 ❑ As .z:; tee:' in kEcl ❑ Per The At -each:-..-- Letter These plans have been reviewed }v The Tukwila Fire Prevention Bureau for ccnfomiarf:r_. T'dth current City standards. Acceptance sub ec t --:(Tors and omissions which do not °a,fi-hori7. ° •racI: ,ails of adopted standards and-ordinancd-s. The iespu :s:oliity for the adequacy of desig'l totally c e designer. Additions, deletioi is or i'evi;o-tOrt i ;,^ thee. drawings after this date will void tn:s ac<:eprai icy; F =?r : 1 require a resubmittal of reviser) drawings for sui {cent approval,. Final acceptance is subject t to field test and inspection by The Tukwila Fire Prevention Bureau. SHEET \UM3ESHEET TITLE FA -01 SYSTEvl 1\FOvATIONN FA -02 TYPICAL WHI\G A\D MOU\TI\G DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LI\E DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX WISE SCHEDULE A\3 CONDUIT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANDERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSCCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE EN\'IRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX EX 3 EX EX SYMBOL DESCRIPTION MODEL Date: • - -1 :' __by; J/ V • I V� BACKBOX NOTICE 4 completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and De;:ection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address for shut- down or r : I tt pproval. MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD -3-ENCL 66" A.F.F. TO TOP ® SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1 G RING CEILING ® D DUCT DETECTOR TSM EX 7 EX HT -R DUCT DETECTOR TEST SWITCH AD2-P W/ SIEMENS DUCT HOUSING HFP-11 DET. TSM -1 SIEMENS 1 -GANG BOX INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD VERIFY IN FIELD VERIFY IN FIELD 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 FIRE ALARM STROBE ZR -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM Di FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1 -1 /2" EXTN HCP INTELLIGENT HCP CONTROL POINT SIEMENS 4S DEEP BOX VERIFY II\I FIELD A.F.F. ABOVE FINISHED N/A FLOOR N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N /A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N /A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND macys LEVELS _5.4O-7s.f GARAGE SPACE #1135 mem, s RELEASE/REVISIONS REV. BY: 0 X DESCRIPTION SHOP DRAWINGS DATE 04/03/13 9a<aaa NORDSTROM 3 LEVELS 171,275st r•3 <<'-1 ?(T.VArk, .,s RARE R,,X ,f; mss; f -i L I Pnr p:4R sr.r�4 r-sa JCPenney tri M T OHO to coW Deo o W <z cn mu) CC z. -J o W • = CC D �+-01- U) ¶;MCAS. ,.,tt, nC,zRE TRE ;r AE PtcAlE • 11.7,47.1 i TAC - •TEAII';:1-0= PAP,C SRWFA4 •[ R,ao MA FRP gR: PA• C.A C yS _ BANv E.r T!; �E�G.e • I� Z,I T.T,,.., 0 Ally PATIO SITE PLAN RESTALPAYT PATO PEP/. PAID r9 (Y--; 7f11 LAM Cc, Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved Z (S -.ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/03/13 BACKROUND PLAN PROVIDED BY: \,1OB NUMBER: 100683} I; SHEET FA -01 } THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE 6-10 DUCT EQUIVALENT DIAMETERS DUCT DETECTOR LOCATION OUTLET SAMPLING TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND AD2-P DUCT DETECTOR MOUNTING DETAIL 0 FROM XLS CONTROL PANEL OR <4- PREVIOUS +PREVIOUS ADDRESSABLE DEVICE END OF LINE DEVICE(3,6K 1/4W) SUPERVISED SWITCH GROUND 0 0 r7 0 HTRI—R OSTATUS LED 0 N. 0 COM 0 1 -F N.C. ' 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. MUSIC LAC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS <4,0A @ 125VAC) (4,OA @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL PREVI❑US ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - 27 VDC 3.5 nA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTION. 1001 TI31 g S g)B e B 1 2 3 4 5 6 TB2 C D oa+-+- 654321 0 JUNCTION BOX —. MOUNTED ON CEILING. FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT / / / / / / / FRONT '/IEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE + DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0- 0 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> T O O 7�5 TO NEXT DEVICE 0 0 —CADDY BAR O f SMOKE DETECTOR \— SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL 0 GND N AC 0 0 0 T 0 PAD -3 0 00 O INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 6 24K HCP MODULE ( PAD -3 TRIP) WIRING DETAIL NAC -4 NAC -3 NAC -2 NAC -1 470 OHMS EOL INPUT 0 9 9 T M-1 O V U 3 J rZ o< ZQoQo C_,0 L" � ACU 0 r-.. •ixOOO 0 • 0 CQC AD2-P DUCT DETECTOR WIRING DETAIL FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) EARTH GROUND --.(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE J( ( ) ( ) STROBE SPEAKER (+) NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERATURE: +32'F (0' C) TO 100' F 38' C) }TUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE tDATA IN( )> DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CON,AINCTION %CH DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW TO NEXT DEVICE-r— ( EVICE — ( ) DATA OUT (+) DATA OUT HFP-1 SMOKE DETECTOR WIRING DETAIL (+) ( ) STROBE (+) ( ) STROBE SPEAKER (+)f 0 SPEAKER STROBE & STROBE WIRING DETAIL SPEAKER STROBE OR STROBE ONLY R 0 TYPICAL WIRING AND MOUNTING DETAILS 4S DEEP BOX W/ 1-1/2" EXTENSION RING — ((SPEAKER STROBE) 4S BOX (STROBE ONLY) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE HARD LID 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N Nx \� CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING/WALL MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 04/03/13 ««< J O ct J SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/03/ 1 3 BACKROUND PLAN PROVIDED BY: ..JOB NUMBER: 100683} C SHEET FA -02 GARAGE EXISTING SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: 04/03/13 Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -W @15Cd 3 0.064 0.192 SET -MC -W @30Cd 2 0.098 0.196 SET -MC -W @75Cd 20.175 0.350 SET -MC -W @110Cd 0.233 SET -MC -CW @15Cd 0.069 SET -MC -CW @30Cd 0.111 SET-MC-CW@75Cd 0.2 SET -MC -CW @95Cd 0.264 ZR -MC -W @l 5Cd 1 0.064 0.064 ZR -MC -W @30Cd 0.098 0.03 Amps 0.832 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.832 Amps For 5 Minutes= 0.070 Amp -hours 25% Derating= 0.987 Amp -hours Total System Current Load: 0.987 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Notification Appliance Circuit Detail !PROJECT: GARAGE Panel: 1 EXISTING PAD -3 POWER SUPPLY _... - CIRCUIT:iS1 QTY Device Type . 3 SET -MC -CW @l5Cd 2 i SET -MC -CW @30Cd `>. SET -MC -CW @75Cd j 200 :Wire Resistance 2.58 CURRENT TOTAL= 893 Alarm Current Alarm Total ! Wire Size : Wire Length Voltage at EOL Circuit Total • 69 2071 i 111 222 SET -MC -W @30Cd I SET -MC -W @75Cd SET -MC -W @110Cd 1ZR-MC-W @15Cd ZR -MC -W @30Cd DEVICES=18 CALCULATIONS { 98 175 233 64 98 TOTAL mA= 400 01 oI 01 64! 8931 14 214 19.41391368 893 Total Wire Resistance (R ) (WL*2)*(R/ft) ;Total Device Load, Amps (I)_ (Total Cct Load) 'Voltage Drop ( E ) (E= I * R) ;EOL Voltage (24 - E) 0.89£ 0.99 23.011 TO BUILDING FIRE ALARM CONTROL PANEL TO EXISTING DATA LOOP (MALL CORRIDOR) EX BPS J S1-1 S1-2 30cd 15cd V-1 S S1-3 15cd V-2 S1-4 15cd V-3 EX EX S1-5 30cd V-4 D b S1 -6 75cd V-5 SINGLE LINE DIAGRAM EX EX S1-7 15cd V-6 S1-8 75cd V-7 EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. REPLACE EXISTING DUCT DETECTOR WITH NEW DUCT DETECTOR. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. W - CD O` co 0\ c0 z •N O o z C\, a Q W w O �i U.) 1-0 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS uJ I- < 0 04/03/13 - ®C oC 0 W `i ..I T .4;W 0WT- L— < oo_z z W < 4 7) CD w , zS Q 2_ cr W Q C!) Q 2 l— z O °CW 0 dig W= CCDD 01— C CO CO 0 W C1) �-- (1) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/03/1 3 BACKROUND PLAN PROVIDED BY: ..JOB NUMBER: 100683 FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET D• ACENT TENANT FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. REPLACE EXISTING DUCT DETECTOR WITH NEW DUCT DETECTOR. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 7 ;cKw1,Z _ . CKROOli (DOOR S1-5 30cd V-4 S,V,V Si -2 15cd S,S' EX S1-7 15cd V-6 v,v S1-1El<IN ® EX 30cd V-1 s EX HCPI =-1-= j A S1-3 15cd V-2 BPS vA s,v,v' HT -R. / f s,v,v' i` ri d -TING JOM .REA �. S1-6 75cd Liq V-5 SALES AREA SA S1-8 EOL 75cd S1 V-7 ENT S1-4 15cd V-3 _ J?!'�`lx\��Y/�\I.�YT 1F7��r'�kf� kT�%?.�l'"�>7••./ t AOJACEN i ENAN1 FIRE ALARM SYSTEM PLAN 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE M M 0 •10 Z 472 p W SS 0 Cn Z WQ JO w rz . wQ �w� Q U_ W I- cc Dn (1) Cr) M ✓SCALE: 1 /4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/03/13 BACKROUND PLAN PROVIDED BY: ,JOB NUMBER: 10068 C SHEET Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved \ FA -04 J APPLE NEW HVAC UNIT FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON ❑ Pef Letter These plans have been reek,:wei by The Tukwila Fire current City :st,nrds. Accept nce is .;so)ect to errors and o...:ii5sions which ai not mutt orizc violationF.--: of adopted s,1zIndarcls and orr'_:.:ances. The respor4ibility for the jacy of desigF: tests totaiiyth t; designer. _ion's d1 Ietif s rci revisions to i i'; 'r (ir 'A'!r gs after t. :.ate will void till;S:.il.'.: jl i �(;.: •�'.:. _ •'iii reg_iire a ii suornitt i cif revis;�.c° 4: ;,,,;,.:. r,�r ..1.,. ;,�,.,`i: approval. nat acceptance is subject to f:e!o cast and InspeCtion•ly 'hie Tukwila Fire Prevention Bureau. Date: / - `I -I By: sl( ,...ate SHEET NUM3E SHEET TITLE FA -01 SYSTEIV INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SI GLE LINE DIAGRAM FA -04 FIRE ALA M SYSTE vl PLA\ SHEET INDEX WI SCHEDULE A\D CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPUFPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vaC POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDU T. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS JSING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY. ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WI -ERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX EX 1 1 1 EX EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of - f_.:_.e2l o=nce Testing of any FireA:3!-ti and Detection ` y,tierts:c Failur-eort::�t�'!'�,..:..Ir i a Fec and ',Y31-rnTn?,t1.0fi of the testinn TUKWILA FIRE.: 1- l F, ► Please caf 4 -1�y ,' C5 yf 6&:t1 give Liliz Fire 1-F-aq and down or MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1 G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS DUCT HOUSING HFP-11 DET. VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM F HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM ❑L STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND AKA mervynis 2 LEVELS 65,23: s1 : �� NORDSTROM3LEVELS L `,l 1 7/ 171,2:55= APPLE #801 ANC: COLT., te'A�r Si`.ER. 3 IXEO GATLIGLA.oltMs =:C nun. srktu Es ECST NC JCPenney W4ICENROCICS vE ±_C T ESS MACE el a'ISf9.".1e sae.:ER C,F75 r~- ICn;'E PEtRII .I UDD- icCO YA' . p11111 N 2 e VA TEAM voR 276,468sf AFEP.CROMSE PI-JitC SUN/F_IR IC251 05174 STAIRS TRW ` ..F. . EMERALD CNY 4 - } SITE PLAN PAID ivriv 25 2013 TUKWILA FIRE 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE M In N 2aa<aa 1 1- Z z D o J� ~ d0) U o2z = wzz wx< vcn z oC W J cc Cl. LL F- 0 0 SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 /25/1 3 BACKROUND PLAN PROVIDED BY: \OB NUMBER: Pro rieta and Confidential, Co. ri•ht 2012 b Guardian Securit S stems, Inc. All Ri• hts Reserved 7399-1j SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ DEDICATE) EMERGENCY —( NOTE FOR ADIXDONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 'CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC I TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE PROM XLS COMM PANEL DR PREVIOUS ADDRESSABLE DEVICE O 4 GROUND HTRI-R 0 O o O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) ORD N L 00 00 0 PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0] a m m a m e 3.6k EOL (-) (+) (-) (+) SPARE , SPARE SPARE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) O WIRE DESIGNATION; NUMBEROF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPLIFPLR RED(JACKET) *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O r 4 1 0 0 0 1 HTRI-Rr, 1 rc\0 GROUND O �� (+)>TO NEXT DEVICE OR (-) > STOP IF LAST DEVICE DRY CONTACTS TO VAV �► FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FLED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL (+) HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY U U HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERATURE: +32' F 0' C TO 100' F (3& C) HUMIDITY: 9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR — FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE r DATA IN( )> 5l DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL 00 00 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX • ^4 `.s+�.Lbye£.a.u`.�.� :+.�j�.�1i�i�a�tst`a� � 4' �eey�d.. 4 v JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT 0 0 r 0 0 TO NEXT DEVICE CADDY BAR E1I SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS M W a o N zco o JO L dO) dQuo = w z z 5?Vt=j) Z LL Qog Wup- wT C4 CLL., 0 �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:1 1 /25/ 13 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 7399-1) r SHEET FA -02 Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 1 0.0635 0.0635 0.064 0.064 HTR -R 0.009600 0.0096 0.021 0.021 0.0731 Amps 0.085 Amps SYSTEM CALCULATIONS CS L LTJ EX EX EX EX EX EX EOL S2 j D FLAG NOTES: DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. v "3 . 1,0 co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE :->2) N 2 aaaa< cc 0 w Z w z 22 D o � (5 Q� U �z < ¢ o �- 0 w� I w zz Z w= aC � U u)W i< (1) Zoc�� Z QHS 0 LlJ w CL J U w Ci) >- Cl) �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:1 1 /25/13 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM ..JOB NUMBER: 7399-1/ SHEET Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved FA -03 J `®" (u' EX EOL S2 EOL S11 EX EX 1-1 s. —G CD PS D ?S EX EX cS FLAG NOTES: DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. v u 1 i ®t EX AREA AREA OF 7 WORK FIRE ALARM SYSTEM PLAN Li 2S EX EES 1 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 3 0 DESCRIPTION SHOP DRAWINGS DATE 11/25/13 2<aaa< " Z 0 Z Z c0ss O _Iv � �z Q o (/) > Q FEF - u) w zZ ( cn (/) Lux x< z�g�- od W w o CC J c co n CLuJ CC �CALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:1 1 /25/ 13 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 7399-1; ( SHEET FA -04 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved APPLE SOUTHCENTER FIRE ALARM SYSTEM TU ILA, WASHINGTON Without Corn tccit ❑ As Noted in Re ❑ Per The Attach &.:. Letter These plans have been reviewed by Me Tukwila Fire -evention Bureau for conformance v,:;rn; current City ndarcis. Acceptance is subject to:if rors and -.nissions which do not authorize violations ::f adopted - . 7.:ndards and ordinances. The responsibility for the ..dequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after SHEET # DESCRIPTION FA -01 SYSTEM INFORMATION/SINGLE LINE DIAGRAM/REMOTE BREAK ROOM FIRE ALARM PLAN SHEET LIST QUANTITY E(2) SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT gE FIRE ALARM HORN STROBE (EXISTING) SLHSCW—F SIEMENS 4S BOX CEILING JUNCTION BOX F.B.O. F.B.O. N/A VERIFY LOCATION IN FIELD E❑L END OF LINE RESIST❑R N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.D. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U,❑.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND RELOCATE TWO(2) EXISTING HORN STROBE OF THE FIRE ALARM SYSTEM. SCOPE OF WORK FROM EXISTING S NAC DEVICES S 3E S1-1 75Cd S S1-2 75Cd EOL S1 RELOCATE EXISTING NAC DEVICE TO NEW SPECIFIED LOCATION. MAINTAIN CIRCUIT CONTINUITY. EXISTING DEVICE RELOCATED TO THIS POINT OF ROOM STORAGE. FROM EXISTING NAC DEVICES REMOTE BREAK ROOM FIRE ALARM PLAN SCALE: 1/4"=1'-0" NORTH CEILING TILE e. resubmittal of revised drawings for subsequent approval Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: / 9 By: A --wt s>" I SPEAKER SUPPORT BRIDGE Fire Permit Number ' �`,c.' ': �t ons To sc� �.��.:�� i��r,c:, call 206-575-4407 4" SQUARE DEEP BOX WITH 2-1/8" EXTENSI❑N CEILING MOUNTED SPEAKER HORN STROBE MOUNTING DIAGRAM (DROP CEILING) HARD LID CEILING SPEAKER SUPPORT BRIDGE 4" SQUARE DEEP BOX WITH 2-1/8" EXTENSI❑N CEILING MOUNTED SPEAKER HORN STROBE MOUNTING DIAGRAM (HARD LID) TYPICAL MOUNTING DETAILS EXPIRES 09/01/2020 1,0 co 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: U m c4 DESCRIPTION SHOP DRAWINGS DATE 12/04/19 CC w co z1 07, Z a) w w 2z O CO wI E �zz E— 2 w = D cc 2u) O Q�� wo Ill �0 a�� 0 N C) CC LU CC LL rn C• C Q C=1 LLI CDCry CC CD LLI CALE: NOT TO SCALE DRAWN BY: R. CRUZ DESIGNED BY: T. QUAALE DATE: 12/04/1 9 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved .JOB NUMBER: 49371—.1} SHEET FA -01./ SDE E S blgelmsi{y-fort f App[i'anc "Stiro ®e' itiiiteet En iiM seclfrcat a s ❑ Sophisticated series of notification appliances that meets fire -industry codes and regulations for commercial -building applications ❑ Compatible with the Siemens 50 -point, 252 -point and 504 -point addressable fire alarm control panels (FACPs), and with: Siemens Modular FACPs - Siemens PAD -series of NAC extenders - FireFinder® XLS /XLSV FACPs - Siemens dual -sync control (DSC) modules ❑ Innovative LED strobe technology provides an energy-efficient means for a significantly reduced current draw - Capabilityto have existing Xenon and new LED strobes in the same field-of-view - Fewer power supplies required, smaller wire gage, reduced wire runs ❑ Straightforward installation coupled with compact, modern design - No visible mounting screws Manual (index finger) slide -setting adjustor - Four (4) field -selectable settings in one (1) device: 15cd130cd1 75cd j 95cd ❑ Faceplates ship in four (4) distinctive types: - "FIRE" 1 "ALERT' J "AGENT" j (blank) ❑ Two (2) audible settings in each notification appliance - Temporal or steady horn output - High or Low setting ❑ UL (2034 1971 1464) and ULC Listed (ULC -S5251- S526) - ADA 1 NFPA( FCC 1 ANS11 OSHA compliant Siemens Building Technologies Division Pro uc Clvenrie� Formed as the 'SL' -series, Siemens is now offering horns, strobes, and horn -strobes to its notification -appliances portfolio. With the 'SL' -series, Siemens now offers an additional range of products with low and high candela settings that makes these sophisticated notification appliances ideal for new installs and retrofit applications. Innovative light -emitting diode (LED) strobe technology provides an energy-efficient means for a significantly reduced current draw. The strobe portion of these appliances meets the 20 millisecond light -pulse - duration requirements of the 2016 edition of NFPA 72. This feature allows existing Xenon and the new LED devices to be used in the same field-of-view. In a single device, the 'SL' -series can provide alarm -signaling tones for dual applications. All strobe models in the series feature multi -candela settings (15 30 75195cd) on a single appliance. Additionally, there are two (2) modes of operation for the audible portion of these notification appliances: • T3 (coded) • Continuous The 'SL' -series of horns, strobes and horn -strobes devices are produced in a sleek, modern design. Its structure and design provide high-quality energy efficiency in an aesthetically pleasing, low -profile design that is consistent to the look of the interior composition of the building application. This 'SL' -series is exclusive to indoor ceiling -mount applications. The Model 'SLHC'- series horn appliances work in either 12V or 24VDC, whereas the Series 'SLSC and 'SLHSC strobe and horn -strobe devices are specifically for 24V operation. ModetFSLHSCR'F Horn -strobe ModeliSLSCW.AL Strobe Model;SLHCR-N Horn Data Sheet 2594 usa.siemens.comlfire SLSHCISeries Ceiling Horn -Strobe sSL"HCSeries1 Ceiling Horn • ec fiMi ns w � In terms of composition and functionality, Models 'SLHC '-series, 'SLSC '-series, and 'SLHSC' series provide added value to the installer for the type; of applications for operation: • Compact I sleek I low -profile design • Comprehensive feature list • Convenient mounting options • Easy -to -adjust selection -slider switch for candela settings — No tools required for setting changes — Multi-level settings: 15cd 130cd I 75cd I 95cd • High and Low audible outputs • Reduced current draw, via cutting-edge LED technobgy The LED portions of the Siemens 'SL' -series of strobes and horn -strobes meet the 20 millisecond light - pulse -duration requirements of the 2016 edition of NFPA 72. By meeting this latest requirement, existing Xenon as well as the new LED -technology devices can now be in the same field-of-view. The horn, strobe and horn -strobes in this Siemens 'SL' -series of notification appliances have received UL / ULC Listed status by attaining compatible testing standards with all of the Siemens fire -alarm control panels (FACPs) and accessories that have been determined to be aligned with existing Siemens strobe -based appliances. This would include the following existing model -types: 'CH' 'HS' 1 'MTH' 1 'S -HQ' 1 'AS' 'SE' 1 'SEF' 1 'SET' 1 'ST' 1 'STH' 'ZR' and 'ZH' Series notification appliances. The regulatory listing also includes the capability for installing the Siemens 'SL' -series sounder -strobes in the same notification zone and field-of-view with any existing Siemens Notification Appliance Xenon -based strobes. All these horns, strobes and horn -strobes models are UL Listed (for indoor use under Standard 1971 and 464), as well as ULC -5525 ULC -5526 Listed. The Siemens 'SU -series sounder -strobes also have ADA 1 RoHS and ICES approval. Siemens Building Technologies Division —2— usa.siemens.com/fire ti `Ele tricalRain • s Ceiling -Mount 1 Horn -Strobes Output Current Draw MODEL 'SLHSC' SERIES:' UL Current Ratings (HIGH dB 1 in Amps) 16.0 - 33.0 VDC Setting 15cd 75cd 195cd Code 3 0.044 0.065 0.182 0.268 Continuous 0.049 0.067 0.187 0.274 MODEL 'SLHSC' SERIES: UL Current Ratings (LOW dB 1 in Amps) 16.0-33.OVDC Setting 15cd ' 30cd 75cd 195cd Code 3 0.042 0.064 0.181 0.256 Continuous 0.045 0.066 0.183 0.271 Ceiling -Mount 1 Horn -Only Output Current Draw MODEL 'SLHC' SERIES:` Current Ratings (Code 3 I in Amps) RMS Current @ 24 Volts DC Regulated Voltage Range, VDC 8.0-17.5VDC High Low 0.024 0.018 16.0-33.0 VDC 0.030 0.022 Ceiling -Mount 1 Strobe -Only Output Current Draw MODEL 'SLSC' SERIES:' Current Ratings (in Amps) RMS Current @ 24 Volts DC Regulated Voltage Range 15cd 30cd 75cd 95cd 16.0 - 33.0 Volts DC 0.040 0.058 0.171 0.256 GENERAL NOTES: 1. Strobes are designed to flash at 1 -flash -per -second minimum over their "Regulated Voltage Range." 2. NFPA-72 specifies a flash rate of 1 -to -2 flashes -per -second, and guidelines for the Americans with Disabilities Act (ADA) specify a flash rate of 1 -to -3 flashes -per -second. 3. All candela ratings represent minimum effective Strobe intensity based on UL 1971. UL ( Ceiling -Mount 1 Horn -Only I Output Current Draw MODEL 'SLHW'- and- 'SLHSW' SERIES:' UL Sound Output Ratings (dBA) Reverberant per UL464 @ 10 feet Volume SLHC @ 12VDC SLHC -and- SLHSC @ 24VDC 8.0V 12.0V 17.5V 16.0V 24.0V 33.0V i I Code 3 I High dBA 75 80 83 76 79 81 Code 3 1 Low dBA 73 77 80 75 77 77 Continuous I High dBA 80 84 87 80 83 86 Continuous I Low dBA 78 79 84 78 81 81 ULC 1 Ceiling -Mount 1 Horn -Only 1 Output Current Draw MODEL 'SLHW'- and - -SLHSW' SERIES:' ULC Sound Output Ratings (dBA) Anechoic per ULCS525-16 @ 3.05 meters Volume SLHW @ 12VDC SLHW -and- SLHSW @ 24VDC 8.0V ( 12.0V 17.5V 16.0V 124.0V 133.0V Code 3 I High dBA 85 89 92 91 95 96 Code 3 I Low dBA 79 84 87 86 190 91 Continuous I High dBA 85 89 92 91 94 97 Continuous I Low dBA 79 84 87 86 90 92 'RMS current ratings are per UL maximum RMS method UL max curren rating is the maximum RMS current within the listed voltage range (16 - 33V for 24V units) For audible appliances, the max current is usually at the maximum listed voltage (16.33V for 24V units) For unfiltered FWR ratings, see installation instruction General Properties OPERATING TEMPERATURE: MODEL "SL' -series - 32°F (0°C) to 122°F (50°C) - for indoor -applications' use only RELATIVE HUMIDITY: 93%, maximum OPERATING VOLTAGE RANGES: - 12VDC/VFWR -) 8-17.5VDC/VFWR; - 24 VDC / VFWR e 16 - 33 VDCNFWR (12 VDC for Model SLHC only) STROBE OUTPUT RATING: - UL 1971, ULC -S526 - Field -selectable 15cd 1 30cd 1 75c 1 95cd candela outputs STROBE FLASH RATE: Strobes are designed to flash at one -flash -per -second STROBE SYNCRONIZATION: - all Siemens addressable panels - Siemens PAD -series NAC extenders - Siemens dual -sync (DSC) modules, which provide the unique Siemens proprietary synchronization protocol TEMPORAL PATTERN: - Continuous - Code 3 (1/2 second on, 1/2 second off; then 1h second on, 1/2 second off; followed by 1/2 second on, 1-1/second off and repeat) NOTES: The Code 3 pattern is specified by ANSI and NFPA 72 for Standard Emergency Evacuation Signaling. Physical Properties MATERIAL: MODEL 'SU -series - White -or -red textured, ultraviolet (UV) stabilized, colored impregnated engineered plastic - Exceeds 94V-0 UL flammability rating WEIGHT: 0.55 Lbs. (0.25 Kg.) LENS TYPE: 'J LED strobe situated in a rugged Lexan lens DIMENSIONS: 3.13" (7.95 cm.) { H }; 3.13" (7.95 cm.) { W }; 1.5" (3.81 cm.) { D } Mounting and Wiring Properties INDOOR MOUNTING: MODEL 'SU -series - Ceiling -mount applications - Model SLSBBC backboxes or to 4' (10.2 cm.) square - 1.5' (cm.) -or- 2.125' (cm.) octagonal - 1.5' (cm.) -or- 2.125' (cm.) deep WIRING TYPE:F'12-e18,American Wire Gauge (AWG) Siemens Building Technologies Division -3- usa.siemens.comlfire NOTICE - The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets — as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product. All are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contac the Manufacturer. SIEMENS dddlIllddddddddiP'.ddPdddddddtdddddd%ld,o'ddddd'dd ...„................ ",dgdddddd!K.,d,!d, iemen industry, ec 0 ogle Division MODEL PART NUMBER APPLIANCE TYPE LJL El MOUNTING TYPE STROBE TYPE FACEPLATE FACEPLATE _ COLOR LETTERING SLHCR-N S54329 -F12 -A1 Horn 1 V Ceiling -None-- RED VI - None - 854329 -F12 -A2 1111511111113111 -None-- IIIIIIIE—:in ill - None - SLHSCW-F S54329 -F13 -A1 Horn -Strobe 1 — C ei I i n g allarill WHITE FIRE SLHSCR-F S54329 -F13 -A2 mini RED FIRE SLHSCR-FB S54329 -F14 -A1 Horn -Strobe 1 Ceiling Clear RED ' , - Pictogram - SLHSCW-FB S54329 -F14 -A2 V ME= IIIIIZBBEIII -Pictogram - SLSCW-F S54329 -F15 -Al 1 — IIMENIIIIIIEZIEMIE FIRE SLSCR-F S54329 -F15 -A2 Strobe 1 — Ceiling am. RED : ,111111111110311111111 SLSCW-FB S54329 -F16 -A11 Strobe Ceiling Clear RED - Picto ram - SLSCR-FB S54329 -F16 -A2 im. 1 NEE= Nmszmi _ Pictogram - SLSCW-AL S54329 -F17 -A1 1 1 IMEMENIMICEMII ALERT SLSCR-AL S54329 -F17 -A2 Strobe '1 MEN Ceiling mom. RED 'I1 ALERT SLSCW-ALA S54329 -F18 -A1 Strobe 1 1 Ceiling Amber WHITE ALERT SLSCR-ALA S54329 -F18 -A2 1 1 Amber RED k Ut ALERT SLSCW-NA S54329 -F19 -A1 Strobe 1 1 Ceiling Amber IIIIIIIIIIMMIM - None - SLSCR-NA S54329 -F19 -A2 1 MEM Amber RED ' , - None - SLSCW-N S54329 -F20 -A1 Strobe 1 — Ceiling Clear 11111E4'11EMEI - None - SLSCR-N S54329 -F20 -A2 1— ma= RED , - None - SLHSCR-A S54329 -F32 -A2 Horn -Strobe 1 1 Ceiling Clear RED ,, AGENT SLHSCW-A S54329 -F35 -A2 i 1 MIEIMIIIMIIEEEIIIIIIIMCEEBIIIIIII SLHSCR-AL S54329 -F33 -A1 Horn -Strobe 1 1Clear Ceiling RED , ALERT SLI -AL S54329 -F36 -A1 1 MIMI WHITE ALERT SLHSCR-N S54329 -F33 -A2 i — Ceiling Clear RED , . - None - SLHSCW-N S54329 -F36 -A2 Horn -Strobe 1 — 11113,1111111MINEM - None - SLSCW-A S54329 -F65 -A1 1 I C ei I i n g Clear IH AGENT SLSCR-A S54329 -F37 -A2 Strobe 1 1 _ immin SLSBBCR S54329 -F55 -A1 v 1 Ceiling -None- RED , „. - None - S LS BBCW S54329 -F55 -A2 Backbox V V -None- WHITE - None - NOTICE - The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets — as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product. All are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contac the Manufacturer. SIEMENS dddlIllddddddddiP'.ddPdddddddtdddddd%ld,o'ddddd'dd ...„................ ",dgdddddd!K.,d,!d, iemen industry, ec 0 ogle Division