PP - 636 SOUTHCENTER MALL - SWAROVSKI - PERMITS AND PLANS
636 SOUTHCENTER MALL ASSOCIATED PERMITS 08-F-125 08-S-060 FILE FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Swarovski 636 Southcenter Mall Permit No.: 08-S-060 Date: March 5, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. All references are NFPA 13, 2007 Edition. FiLE COPY FIRE A .AM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE •FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL) FA -04 FIRE ALARM SYTEM FA -05 WESTFIELD SOUTHCENTER MALL SITE PLAN 0 0 rur.wILA FIRE CEP -AR -Tit -EAT, Without Comments As Noted In Red Per The Attached Lettor !nese plans have ben reviewed by The Tukt.vit?.. Fire Prevention Bureau for corlformance wTh current city standards. Acceptance is t!,,ubiect to errors and omissions which co not authorize vici:_itions of adopted standards and o:-,Jin.•..iric,iis. l'il.i.: r,-.:,!:,...7,1-Isbny fertile adequacy of de:-..ii:)ii i --..-,.z-L. toi.i,:i,.‘ •,,'.1',-, ine dgner. Additions, diawings atter this dote will void th nd require a iesubmittal of revd drw far subsequent approval. t Final accptance s;.tl..ect to field test and inspection b,/ The Tukwila Fitt--; Prcvoon Bureau. Date: L1 -/g - 02 By: Evu /0(k:s4 cle.vcce Qt,ectca/L-4 FA" ) k•-• r (.411;- 6% -t -444c,.. • Please call: 575-440Z and give this job No. 03 F - and exact address for shut' wn or restoration approve!: • NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD 1412 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWO #14 FPL/FPLR RED (JACKET), V' SPEAKER CIRCUIT - RETURN TWO. . 1414 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDIO TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR. RED (JACKET) CONDUIT FILL CHART . _ . . ... .- - . _ ,,...,...... . _ NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.0. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TEl BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSCCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN W11 -1-i RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS.!: 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C: AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF.FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES ,SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. .12. ALL MANUAL PULL STATIONS SHALL BE. MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL • TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS; 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A.: PERMANENT LABEL AT. ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN, ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNITOESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF •6.4..2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 0 1 2 1 2 . _ • SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE OD DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -CW SIEMENS SET -MC ---W SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM sc FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -HMC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. 111C FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING L FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX WI 1G RING 80" A.F.F. TO BOTTOM U.O.N. 9c FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS .• 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM , 1130 WP FIRE ALARM STROBE • (WEATHERPROOF) SET -S17 -WP , SIEMENS • MT -SUR -BOX • VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JBEIX FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD 0 JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F:B.O, FURNISHED BY OTHERS N/A N/A • N/A • N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED. AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN • AS BUILT REMOVE N/A ... • - - N/A N/A . . N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAID Am 1 7 2008 Tukwila Fire_ 9-5v i5occ..-' Co yn ht 2006 b Guardian Securit S stems, Inc. All Ri hts Reserved , r' -.1- CD 1,r) ON c0 ON co : c'F CD 'CD ‘O C , DE 00 LU F - _J < :Th! LIJ IC) F- 00 Uj < 5.0 c) U) - tr) • F_ • 0 '0) LU Lu U) Lu Lu CZ 14 s. LU DESCRIPTION Ui F- 0 r z. Z c0fl LT -Io (i) z wir2 fr CC < g cncc E. a.) \in o- cr)D CD I- ?SCALE: 1 /8" = 1 DRAWN BY: •11ANDERSON DESIGNED BY: .VEZZANI •DATE: 4/07/08 BACKROUND PLAN PROVIDED BY: • ,00B NUMBER: SHEET FA -01 111E DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT V DTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' Y4DE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. OUTLET SAMPLING TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND FRONT VIEW a NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0 to 0- 470 OHMS EOL 0 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT DUCT DETECTOR LOCATION EASE SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP W LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC! END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH e.o o 0 ro 0 �1- GROUND-0 Ln O O HTRI—R STATUS LED 00 0 N.O. 0 N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O p TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SME cr (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE- TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE MUSIC }-AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING O TO NEXT ADDRESSABLE DEVICE foL.4 STOP IF LAST DEVICE 1(-) FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE (-) RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02u F 0.04 u F 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. ma±es) ais, a 1.2.3.•4 5-6 TB2 CP ee 65 0 END OF LINE ?/2- (3.6K 0 J - DEVICE 2- V 0 (3.6K 1/4W) i' SUPERVISED_____/ SWITCH • GROUND ---': ® O HTRI—D STATUS LED 0 NOT USED O NOTE:. FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. END OF LINE DEVICE 3.6K 1/4W) \`- UPERVISED 1 SWITCH Alk TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL v LABEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) - 0. GNDN.AC 0 00 00 El 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1-.1..2+2- 2 NC C NO "4- - t -"- +•- + - EA DT Im NOM 24K TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE NAC -4 2 NAC -3 2 NAC -2 NAC -1 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) TSM -1 0 iz < mood 'J oR t103r- o IP MO • FL2_3_4_5. c c0 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SC .E: NONE C STROBE) SPEAKER (-Y-) STROBE-) NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPFR TIN TEMPFRA 432'F 0- C) TO 1W (36C }TUMIDITY: X RELATIVE HUMIDITY. NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS US1ED FOR AIR VDEOQTY APPUCATIONS OF 300-4000 FT/MIN MEN USED IN CON,IJNCTION IMTH DUCT HOUSINGS AD -11P OR AD-11XPR D8-11 STANDARD SMOKE DETECTOR BASE EARTH GROUND -3.(-0To NEXT DEVICE OR >(-) STOP IF LAST DEVICE (-a) ( ) STROBE SPEAKER (+) (-) SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY •80'" kF.F. 4S DEEP BOX W/ 1 -1/2 - EXTENSION RING (SPEAKER STROBE) 4S BOX' (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE r FROM PREVIOUS ADDRESSABLE DEVICE OR PO11ER SOURCE DATA IN (-) >--- DATA IN (+) > REAR MEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL TO NEXT DEVICE OUT ) DATA O (+) DATA OUT LABEL SCAI.E CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING HARD LID --.\ SPEAKER SUPPORT TILE BRIDGE ,, 4' SQUARE DEEP BOX ---,.-- WITH 1-1/2' EXTENSION 'N �- CEILING MOUNTED SPEAKER/STROBE I, o° 000 CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTI❑N BOX MOUNTED ON \\ CEILING, FLEX �. JUNCTI❑N BOX -------� MOUNTED AGAINST CEILING SUPPORT / / / / / / •\ O O I TO NEXT DEVICE ---CADDY BAR SMOKE DETECTOR -- SMOKE DETECTOR MOUNTING SCALE=NONE -- SUSPENDED ILLUMINATED CEILING DATE: 4/07/08 BACKROUND PLAN PROVIDED BY: 3:1 ilOB NUMBER: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -02 • EOL1 19.58V 0 30' STOCK ROOM • • ' 15' 15' ALES AREA 0 -v....—. • .. • . . ,„. „wit, i 11 : montin timmorit lamm D,2V,2S - - \'IS',2 0 : iT4 2S,2V V•• 2S,2V 2S,2V 2S,2V - 2S,2V .1 • •. / C s.i•Sci:1 .1\ 110 imitiiimimirnm FIRE ALARM PLAN 7"-j- I,S • I !'! • CY) D CO SCALE: 1/8"=1' -7\- bRAWN BY: flANDERSON DESIGNED BY: .VEZZANI •-•P gi; • •' b NUMBER: • .• ?.i Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 11 i •.:•{{1 0ATE:4/07/08 BACKROUND PLAN PROVIDED BY: •;: ;; SHEET '44 tf, _ .... • E I 1 L E Pi i\ • ii.N•1 Ski OP L. tyl EL C li.t ------ P C `.E; N VVEEIAR• • • tvtv --------- LiJ D. EI 545 I 540 RECIal?-1:; SiC:RACF_ El !CAN 1"-d A PI L. 77 TCHEN e M 01 I CZ LiJ t t)0.1N( PiSER , l'.3.;!•.'• NORTH rJ ne- LLJ 1125 1 .JLU SWAROVSKI c) E:ASi•KIN ROBE3P:\-IS ME N 1;11 • • • ; SYSTEM CALCULATIONS Alf -u LLUM INA1I ONS STARBUCKS F CHUANG'S „ r • t---.‹.:15 s72. „ 17•17)72.22:11F,t.:11 SWAROVSKI WESTFIELD SOUTHCENTER MALL SCALE 1/32'.7-11 S,2V 2S,2V 2S,2V 110 S,2V 30 D D,I D7' 15 cp-2S,2V FA -BOX D FACP EX : I - S,V PSL s'a [14-80 r 1 Lite) U pl55 H 1_1-) 11 ----- LLECTi-t1Ch Rkt. A fL.. F?ECYCLING SlORACE 1)1 SWAROVSKI FACP ADD ONS SWAROVSKI FACP ADD ONS Current Load: Load: Standby: Alarm: Current Load: Standby: Alarm: Device Type HFP-11 AD2-P HTR -R HTRI-D Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total 0.0022 0.0022 0.0023 HFP-11 1 2 0.0635 0.009600 0.001600 0.0635 0.0096 0.064 0.021 0.0035 0.064 0.042 0.0731 Amps 0.106 Amps AD2-P HTR -R _ HTRI-D 1 2 1 0.0022 0.0635 0.009600 0.001600 0.0022 0.0635 0.0096 0.0016 0.0023 0.064 0.021 0.0035 0.064 0.042 0.004 4t. 0.0747 Amps 0.1095 11. Amps• t; Standby Current Load: • 0.0731 Amps For 24 Hours = 1.754 Amp -hours Standby Current Load: � 0747 Amps For 24 Hours = 1.793 Amp -hours • Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours Alarm Current Load: 0.1095 Amps For 5 Minutes= 0.009 Amp -hours I ! t?1 i143 i• I" 25% Derating= 2.204 Amp -hours 25% Derating= 2.252 Amp -hours 1'0 1 1.. 1 • if,' ii Total System Current Load: 2.204 Amp -hours Total System Current Load: 2.252 Amp -hours Battery Pair to be Used: 12VDC ,Amp -hours 7AH Battery Pair to be Used: 12VDC Amp -hours 7AH )COCK RECOMMENDED MINIMUM BATTERY SIZE = 7, 00 ArnperexHours BATTERY SIZING CALCULATION • • - - t 'T" , NOtification Appliance Circuit Detail , , i i PROJECT WESTFIELD SOUTHCENTER MALL , , ! ; f , I Panel: ISWAROVSKI Wire Resistance :3.24 . , , , ! Date: i April 17, 2008 , , ' CURRENT TOTAL=1530 S1 CIRCUIT ! • t i . • ; , ( ; .•..„_____ .._ _ . , ' 1Alarm Current Alarm Total Wire Size 1 Wire Length 1 Voltage at EOL 1 Circuit Total i ! QTY i Device Type 1 i SET -MC @15CD I- 117' 1171 , . : 1 Total Wire Resistance (. R ) , . 1.56 1 i SET -MC @30CD ; i ( WL * 2 ) * (Rift) 180- 180! 0 !SET -MC ©75CD 2971 o „ • 1 1SET-MC @110CD 2331 233i . : !Total Device Load, Amps (I) ! 0.51 1 ' _("MtalCct L(Dad)I.,..__...___....,._....._._,_... 0 SET -HMC -C@1 15CD ;' 318 01 , ' ' t 1 0 , i SET-HMC-C@177CD ,. 4451 I 0 1 ; • - . . , ; 1 i o i SET -HMC @135CD ' 318f 0 1 I ; , . ..4 -:-. 4451 01 1 1 , ; 1 i i t 23 0)SET-HMC @185CD , . ) - f - 1 • o -iz-mc@i5cD 1 1 1 i 1 - 0 : , i .! ii' , o i z-mc@30CD 200 Oi . i o tSET-MC-CW@110CD DEVICES= , TOTAL m2A64=1I 01 ! i 1 . , 1 : 530! 12 240 i 530 19.575744 Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: SWAROVSKI -4- : Date: i Apri117, 2008 „- ! CURRENT TOTAL= 9 CIRCUIT: SPEAKER CIRCUIT Wire Resistance 5.16 QTY Device Type ;Alarm Current] Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 5 70.7V 1/8 ! 1.81 91 0 b 0 00), i ..... Total Device Load, Amps (I) 0..0• 11 o0(Total Cct Load) i 01 _c , ; -VoltageDrop(E) i oi(E=l*R)' i 0 oi 0 IEOLVoltage20351 0 ii i 1 (204-E) 0' O TotalWire Resiance(R ) 5.16 ( WL * 2 )* (R/ft) 0 - 0.05i , - 0 01 1• , ! : t 1 , i , 1 DEVICE -S=15 ; ) i 12 i 500 20.35356 TOTAL m A= 9 - : • : RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security - 1313 •,. 1 t": 1 1 RELEASE/REVISIONS • DESCRIPTION 00 co /SCALE: 1 /811=1. • DRAWN BY: 'ANDERSON 11. DESIGNED BY: R.VEZZANI DATE: 4/07/08 BACKROUND PLAN PROVIDED BY: • .;, Systems, Inc. All Rights Reservgd GENERAL LEGEND —a —4 BOD BOB BOJ FOS FOW EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPUNG ( UNLESS NOTED ) CAP PLUG CENTERLINE HYDRAULIC REFERENCE POINT CENTERLINE PIPE TO BOTTOM OF DECK CENTERUNE PIPE TO BOTTOM OF BEAM CENTERLINE PIPE TO BOTTOM OF JOIST FACE OF STUD FACE OF WALL FOC AFF CH R.C. V' 4 E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR COLING HEIGHT REDUCING COUPLING OUTLET COUPUNG WELDED OUTLET "FIT" FITTING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALso "GT") THREAD/"Fr (ALSO "FxT") ALL—THREAD ROD PIPING LEGEND EXISTING PIPING NEW PIPING .01 '4 (DI u X ' U (E) U _ — — 11/2 /-io 11/2 11/2 11/2 � 11/2 11/2 I 11/2 I / - / `�' / , 8-10 10-10 10-4 / 10-4 9-8 / n 10-8 + 13'- 0000 o000 0000 0000 0 0 0 0 I 0 0 o 0 0 0 X X 0 o 1I 1 1 /2 +12'-0" CH +12'-0" CH GWB +10'- 11/2 I-1-0\ /2-4 1 1/2 11/2 11/2 0000 11/2 5000 - - 0000 11/2 0000 1 : 000 1 7-4 10-10 10-4 10-4 9-8 10-8 r* AE IN TOILET RM OVE TOILET RM I ry I -1- 1" ARM—OVERS TYPICAL HANG ALL ARM—OVERS GREATER THAN 12" I SWAROVSKI TENANT SPRINKLERS TENANT SPRINKLER PLAN SCALE: 1/4" = 1'-0" ® RELIABLE MODEL Fl -FR QUICK RESPONSE RECESSED CHROME PENDENT 1/2" 155' RELIABLE MODEL F4 -FR QUICK RESPONSE CONCEALED PENDENT CHROME PLATE 1/2" 155' QTY 6 10 PROJECT TOTAL: 16 GENERAL NOTES SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 — 2002 ED ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS SPRINKLER HEADS TO BELOCATED IN CENTER POINT OR QUARTER POINT OF CEILING 11LE TENANT SHELL SPRINKLER SYSTEM ORIGIANLLY CALCULATED FOR ORDINARY HAZARD GP 2 — .20 / 1500 SF ORDINARY HAZARD OCCUPANCY: 130 S.F. PER SPRINKLER MAX NEW PIPING TO BE 'DYNA—THREAD' THREADABLE THINWALL 1/2" CH IP CH 2" CH 0 \Mthaut Comments ❑ As Noted In Red Per The Attached Letter i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is 4ubiect to errors and omissions which do not authorize violations of adopted stanaaras and orae antes. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this,acceptanCe and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: _ J g By: kt-"I 31 I TUKWILA FIRE DEPARTMEN1 Please call: 575.4407 and .dive this job hd.o8-s-o�� - and exact address for shun 1 )own or restdration approval PAID 2008 Tukwila Fire tI 25 (Bct d& 365 CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Swarovski RP - AY Level 1- Store # 1123 / SRVL #183 Tukwila, WA 90025 DATE: 03/08 DRAWN: C.A. SCALE: NOTED 1 OF 1 636 SOUTHCENTER MALL ASSOCIATED PERMITS 08-F-125 08-S-060 FILE FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Swarovski 636 Southcenter Mall Permit No.: 08-S-060 Date: March 5, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. All references are NFPA 13, 2007 Edition. FiLE COPY FIRE A .AM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE •FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL) FA -04 FIRE ALARM SYTEM FA -05 WESTFIELD SOUTHCENTER MALL SITE PLAN 0 0 rur.wILA FIRE CEP -AR -Tit -EAT, Without Comments As Noted In Red Per The Attached Lettor !nese plans have ben reviewed by The Tukt.vit?.. Fire Prevention Bureau for corlformance wTh current city standards. Acceptance is t!,,ubiect to errors and omissions which co not authorize vici:_itions of adopted standards and o:-,Jin.•..iric,iis. l'il.i.: r,-.:,!:,...7,1-Isbny fertile adequacy of de:-..ii:)ii i --..-,.z-L. toi.i,:i,.‘ •,,'.1',-, ine dgner. Additions, diawings atter this dote will void th nd require a iesubmittal of revd drw far subsequent approval. t Final accptance s;.tl..ect to field test and inspection b,/ The Tukwila Fitt--; Prcvoon Bureau. Date: L1 -/g - 02 By: Evu /0(k:s4 cle.vcce Qt,ectca/L-4 FA" ) k•-• r (.411;- 6% -t -444c,.. • Please call: 575-440Z and give this job No. 03 F - and exact address for shut' wn or restoration approve!: • NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD 1412 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWO #14 FPL/FPLR RED (JACKET), V' SPEAKER CIRCUIT - RETURN TWO. . 1414 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDIO TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR. RED (JACKET) CONDUIT FILL CHART . _ . . ... .- - . _ ,,...,...... . _ NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.0. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TEl BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSCCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN W11 -1-i RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS.!: 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C: AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF.FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES ,SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. .12. ALL MANUAL PULL STATIONS SHALL BE. MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL • TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS; 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A.: PERMANENT LABEL AT. ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN, ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNITOESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF •6.4..2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 0 1 2 1 2 . _ • SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE OD DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -CW SIEMENS SET -MC ---W SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM sc FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -HMC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. 111C FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING L FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX WI 1G RING 80" A.F.F. TO BOTTOM U.O.N. 9c FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS .• 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM , 1130 WP FIRE ALARM STROBE • (WEATHERPROOF) SET -S17 -WP , SIEMENS • MT -SUR -BOX • VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JBEIX FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD 0 JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F:B.O, FURNISHED BY OTHERS N/A N/A • N/A • N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED. AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN • AS BUILT REMOVE N/A ... • - - N/A N/A . . N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAID Am 1 7 2008 Tukwila Fire_ 9-5v i5occ..-' Co yn ht 2006 b Guardian Securit S stems, Inc. All Ri hts Reserved , r' -.1- CD 1,r) ON c0 ON co : c'F CD 'CD ‘O C , DE 00 LU F - _J < :Th! LIJ IC) F- 00 Uj < 5.0 c) U) - tr) • F_ • 0 '0) LU Lu U) Lu Lu CZ 14 s. LU DESCRIPTION Ui F- 0 r z. Z c0fl LT -Io (i) z wir2 fr CC < g cncc E. a.) \in o- cr)D CD I- ?SCALE: 1 /8" = 1 DRAWN BY: •11ANDERSON DESIGNED BY: .VEZZANI •DATE: 4/07/08 BACKROUND PLAN PROVIDED BY: • ,00B NUMBER: SHEET FA -01 111E DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT V DTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' Y4DE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. OUTLET SAMPLING TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND FRONT VIEW a NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0 to 0- 470 OHMS EOL 0 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT DUCT DETECTOR LOCATION EASE SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP W LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC! END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH e.o o 0 ro 0 �1- GROUND-0 Ln O O HTRI—R STATUS LED 00 0 N.O. 0 N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O p TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SME cr (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE- TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE MUSIC }-AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING O TO NEXT ADDRESSABLE DEVICE foL.4 STOP IF LAST DEVICE 1(-) FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE (-) RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02u F 0.04 u F 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. ma±es) ais, a 1.2.3.•4 5-6 TB2 CP ee 65 0 END OF LINE ?/2- (3.6K 0 J - DEVICE 2- V 0 (3.6K 1/4W) i' SUPERVISED_____/ SWITCH • GROUND ---': ® O HTRI—D STATUS LED 0 NOT USED O NOTE:. FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. END OF LINE DEVICE 3.6K 1/4W) \`- UPERVISED 1 SWITCH Alk TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL v LABEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) - 0. GNDN.AC 0 00 00 El 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1-.1..2+2- 2 NC C NO "4- - t -"- +•- + - EA DT Im NOM 24K TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE NAC -4 2 NAC -3 2 NAC -2 NAC -1 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) TSM -1 0 iz < mood 'J oR t103r- o IP MO • FL2_3_4_5. c c0 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SC .E: NONE C STROBE) SPEAKER (-Y-) STROBE-) NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPFR TIN TEMPFRA 432'F 0- C) TO 1W (36C }TUMIDITY: X RELATIVE HUMIDITY. NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS US1ED FOR AIR VDEOQTY APPUCATIONS OF 300-4000 FT/MIN MEN USED IN CON,IJNCTION IMTH DUCT HOUSINGS AD -11P OR AD-11XPR D8-11 STANDARD SMOKE DETECTOR BASE EARTH GROUND -3.(-0To NEXT DEVICE OR >(-) STOP IF LAST DEVICE (-a) ( ) STROBE SPEAKER (+) (-) SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY •80'" kF.F. 4S DEEP BOX W/ 1 -1/2 - EXTENSION RING (SPEAKER STROBE) 4S BOX' (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE r FROM PREVIOUS ADDRESSABLE DEVICE OR PO11ER SOURCE DATA IN (-) >--- DATA IN (+) > REAR MEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL TO NEXT DEVICE OUT ) DATA O (+) DATA OUT LABEL SCAI.E CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING HARD LID --.\ SPEAKER SUPPORT TILE BRIDGE ,, 4' SQUARE DEEP BOX ---,.-- WITH 1-1/2' EXTENSION 'N �- CEILING MOUNTED SPEAKER/STROBE I, o° 000 CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTI❑N BOX MOUNTED ON \\ CEILING, FLEX �. JUNCTI❑N BOX -------� MOUNTED AGAINST CEILING SUPPORT / / / / / / •\ O O I TO NEXT DEVICE ---CADDY BAR SMOKE DETECTOR -- SMOKE DETECTOR MOUNTING SCALE=NONE -- SUSPENDED ILLUMINATED CEILING DATE: 4/07/08 BACKROUND PLAN PROVIDED BY: 3:1 ilOB NUMBER: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -02 • EOL1 19.58V 0 30' STOCK ROOM • • ' 15' 15' ALES AREA 0 -v....—. • .. • . . ,„. „wit, i 11 : montin timmorit lamm D,2V,2S - - \'IS',2 0 : iT4 2S,2V V•• 2S,2V 2S,2V 2S,2V - 2S,2V .1 • •. / C s.i•Sci:1 .1\ 110 imitiiimimirnm FIRE ALARM PLAN 7"-j- I,S • I !'! • CY) D CO SCALE: 1/8"=1' -7\- bRAWN BY: flANDERSON DESIGNED BY: .VEZZANI •-•P gi; • •' b NUMBER: • .• ?.i Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 11 i •.:•{{1 0ATE:4/07/08 BACKROUND PLAN PROVIDED BY: •;: ;; SHEET '44 tf, _ .... • E I 1 L E Pi i\ • ii.N•1 Ski OP L. tyl EL C li.t ------ P C `.E; N VVEEIAR• • • tvtv --------- LiJ D. EI 545 I 540 RECIal?-1:; SiC:RACF_ El !CAN 1"-d A PI L. 77 TCHEN e M 01 I CZ LiJ t t)0.1N( PiSER , l'.3.;!•.'• NORTH rJ ne- LLJ 1125 1 .JLU SWAROVSKI c) E:ASi•KIN ROBE3P:\-IS ME N 1;11 • • • ; SYSTEM CALCULATIONS Alf -u LLUM INA1I ONS STARBUCKS F CHUANG'S „ r • t---.‹.:15 s72. „ 17•17)72.22:11F,t.:11 SWAROVSKI WESTFIELD SOUTHCENTER MALL SCALE 1/32'.7-11 S,2V 2S,2V 2S,2V 110 S,2V 30 D D,I D7' 15 cp-2S,2V FA -BOX D FACP EX : I - S,V PSL s'a [14-80 r 1 Lite) U pl55 H 1_1-) 11 ----- LLECTi-t1Ch Rkt. A fL.. F?ECYCLING SlORACE 1)1 SWAROVSKI FACP ADD ONS SWAROVSKI FACP ADD ONS Current Load: Load: Standby: Alarm: Current Load: Standby: Alarm: Device Type HFP-11 AD2-P HTR -R HTRI-D Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total 0.0022 0.0022 0.0023 HFP-11 1 2 0.0635 0.009600 0.001600 0.0635 0.0096 0.064 0.021 0.0035 0.064 0.042 0.0731 Amps 0.106 Amps AD2-P HTR -R _ HTRI-D 1 2 1 0.0022 0.0635 0.009600 0.001600 0.0022 0.0635 0.0096 0.0016 0.0023 0.064 0.021 0.0035 0.064 0.042 0.004 4t. 0.0747 Amps 0.1095 11. Amps• t; Standby Current Load: • 0.0731 Amps For 24 Hours = 1.754 Amp -hours Standby Current Load: � 0747 Amps For 24 Hours = 1.793 Amp -hours • Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours Alarm Current Load: 0.1095 Amps For 5 Minutes= 0.009 Amp -hours I ! t?1 i143 i• I" 25% Derating= 2.204 Amp -hours 25% Derating= 2.252 Amp -hours 1'0 1 1.. 1 • if,' ii Total System Current Load: 2.204 Amp -hours Total System Current Load: 2.252 Amp -hours Battery Pair to be Used: 12VDC ,Amp -hours 7AH Battery Pair to be Used: 12VDC Amp -hours 7AH )COCK RECOMMENDED MINIMUM BATTERY SIZE = 7, 00 ArnperexHours BATTERY SIZING CALCULATION • • - - t 'T" , NOtification Appliance Circuit Detail , , i i PROJECT WESTFIELD SOUTHCENTER MALL , , ! ; f , I Panel: ISWAROVSKI Wire Resistance :3.24 . , , , ! Date: i April 17, 2008 , , ' CURRENT TOTAL=1530 S1 CIRCUIT ! • t i . • ; , ( ; .•..„_____ .._ _ . , ' 1Alarm Current Alarm Total Wire Size 1 Wire Length 1 Voltage at EOL 1 Circuit Total i ! QTY i Device Type 1 i SET -MC @15CD I- 117' 1171 , . : 1 Total Wire Resistance (. R ) , . 1.56 1 i SET -MC @30CD ; i ( WL * 2 ) * (Rift) 180- 180! 0 !SET -MC ©75CD 2971 o „ • 1 1SET-MC @110CD 2331 233i . : !Total Device Load, Amps (I) ! 0.51 1 ' _("MtalCct L(Dad)I.,..__...___....,._....._._,_... 0 SET -HMC -C@1 15CD ;' 318 01 , ' ' t 1 0 , i SET-HMC-C@177CD ,. 4451 I 0 1 ; • - . . , ; 1 i o i SET -HMC @135CD ' 318f 0 1 I ; , . ..4 -:-. 4451 01 1 1 , ; 1 i i t 23 0)SET-HMC @185CD , . ) - f - 1 • o -iz-mc@i5cD 1 1 1 i 1 - 0 : , i .! ii' , o i z-mc@30CD 200 Oi . i o tSET-MC-CW@110CD DEVICES= , TOTAL m2A64=1I 01 ! i 1 . , 1 : 530! 12 240 i 530 19.575744 Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: SWAROVSKI -4- : Date: i Apri117, 2008 „- ! CURRENT TOTAL= 9 CIRCUIT: SPEAKER CIRCUIT Wire Resistance 5.16 QTY Device Type ;Alarm Current] Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 5 70.7V 1/8 ! 1.81 91 0 b 0 00), i ..... Total Device Load, Amps (I) 0..0• 11 o0(Total Cct Load) i 01 _c , ; -VoltageDrop(E) i oi(E=l*R)' i 0 oi 0 IEOLVoltage20351 0 ii i 1 (204-E) 0' O TotalWire Resiance(R ) 5.16 ( WL * 2 )* (R/ft) 0 - 0.05i , - 0 01 1• , ! : t 1 , i , 1 DEVICE -S=15 ; ) i 12 i 500 20.35356 TOTAL m A= 9 - : • : RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security - 1313 •,. 1 t": 1 1 RELEASE/REVISIONS • DESCRIPTION 00 co /SCALE: 1 /811=1. • DRAWN BY: 'ANDERSON 11. DESIGNED BY: R.VEZZANI DATE: 4/07/08 BACKROUND PLAN PROVIDED BY: • .;, Systems, Inc. All Rights Reservgd GENERAL LEGEND —a —4 BOD BOB BOJ FOS FOW EARTHQUAKE BRACING PIPE HANGER GROOVED CAP RIGID COUPUNG ( UNLESS NOTED ) CAP PLUG CENTERLINE HYDRAULIC REFERENCE POINT CENTERLINE PIPE TO BOTTOM OF DECK CENTERUNE PIPE TO BOTTOM OF BEAM CENTERLINE PIPE TO BOTTOM OF JOIST FACE OF STUD FACE OF WALL FOC AFF CH R.C. V' 4 E/C C/C C/E GG TG TxF ATR FACE OF CONCRETE ABOVE FINISHED FLOOR COLING HEIGHT REDUCING COUPLING OUTLET COUPUNG WELDED OUTLET "FIT" FITTING END TO CENTER CENTER TO CENTER CENTER TO END GROOVE/GROOVE THREAD/GROOVE (ALso "GT") THREAD/"Fr (ALSO "FxT") ALL—THREAD ROD PIPING LEGEND EXISTING PIPING NEW PIPING .01 '4 (DI u X ' U (E) U _ — — 11/2 /-io 11/2 11/2 11/2 � 11/2 11/2 I 11/2 I / - / `�' / , 8-10 10-10 10-4 / 10-4 9-8 / n 10-8 + 13'- 0000 o000 0000 0000 0 0 0 0 I 0 0 o 0 0 0 X X 0 o 1I 1 1 /2 +12'-0" CH +12'-0" CH GWB +10'- 11/2 I-1-0\ /2-4 1 1/2 11/2 11/2 0000 11/2 5000 - - 0000 11/2 0000 1 : 000 1 7-4 10-10 10-4 10-4 9-8 10-8 r* AE IN TOILET RM OVE TOILET RM I ry I -1- 1" ARM—OVERS TYPICAL HANG ALL ARM—OVERS GREATER THAN 12" I SWAROVSKI TENANT SPRINKLERS TENANT SPRINKLER PLAN SCALE: 1/4" = 1'-0" ® RELIABLE MODEL Fl -FR QUICK RESPONSE RECESSED CHROME PENDENT 1/2" 155' RELIABLE MODEL F4 -FR QUICK RESPONSE CONCEALED PENDENT CHROME PLATE 1/2" 155' QTY 6 10 PROJECT TOTAL: 16 GENERAL NOTES SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 — 2002 ED ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS SPRINKLER HEADS TO BELOCATED IN CENTER POINT OR QUARTER POINT OF CEILING 11LE TENANT SHELL SPRINKLER SYSTEM ORIGIANLLY CALCULATED FOR ORDINARY HAZARD GP 2 — .20 / 1500 SF ORDINARY HAZARD OCCUPANCY: 130 S.F. PER SPRINKLER MAX NEW PIPING TO BE 'DYNA—THREAD' THREADABLE THINWALL 1/2" CH IP CH 2" CH 0 \Mthaut Comments ❑ As Noted In Red Per The Attached Letter i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is 4ubiect to errors and omissions which do not authorize violations of adopted stanaaras and orae antes. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this,acceptanCe and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: _ J g By: kt-"I 31 I TUKWILA FIRE DEPARTMEN1 Please call: 575.4407 and .dive this job hd.o8-s-o�� - and exact address for shun 1 )own or restdration approval PAID 2008 Tukwila Fire tI 25 (Bct d& 365 CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Swarovski RP - AY Level 1- Store # 1123 / SRVL #183 Tukwila, WA 90025 DATE: 03/08 DRAWN: C.A. SCALE: NOTED 1 OF 1