Loading...
HomeMy WebLinkAboutPP - 646 SOUTHCENTER MALL - PINK - PERMITS AND PLANS646 SOUTHCENTER MALL ASSOCIATED PERMITS 18-F-026 08-F-179 17-S-223 08-S-132 4401% CITY OF TUIWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION / (P lvc King Co. Assessor's Tax No.: Site Address: 77 f %774/ Suite Number �• L�—fyoor: Tenant Name: \ Yl V C- Y\& SGcxe' New Tenant? ❑ - Yes ❑ - No Property Owner's Name: \Jj r ti Sri �� j✓ �jr'' Mailing Address: 2 601 Pty it Man - / 1,z1o)1 a, L9 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: CrisVN•e_. D \c Day Telephone: Company Name: br 1 F Y F"DCt17OY? / In G Mailing Address: 1r) F,X \.2.-\\> • 1 , l \A r -C CO -w� 1%0%2_ ity E-mail Address:k5 C 'r ,rt>. C C)YYl Fax Number l! 1 Contractor's City of Tukwila NICET III number: q7 • OSen • C& Business License number: B vs • Q g9 6- g! 2. Total number of new/relocated devices or sprinlder heads: 51 Valuation of Project (contractor's bid price): $ `01 • Scope of Work (please provide detailed information): M6.. t- 1neos PERMIT APPLICATION NOTES Vahre of Construction — In all cases, a value of construction amount should be entered by the applicant This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Print Name: Plan Permit App.doc OR AUTHORIZED AGENT: CA Date: 11•15.r7 4SV x 7 J7SO77 Day Tom: 4/25• 171/' 70679 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** (� � RAY ^ n I ^ King Co. Assessor's Tax No.:g2OZ r 00) 0 Site Address:1220 �/1 l.'(,AY h'I,at Suite Number: ) Floor: Tenant Name: V (C 1 U CU C k New Tenant? ❑ - Yes No Property Owner's Name:" C G I C Mailing Address: CONTACT PERSON -if there are questions about the submittal. �/l Name: � int �' ' I Day Telephone: 2Z-(Q5q Company Name: U 1 / I L'i i JCk}(f\74-I (1'e41(l S' City State Zip Mailing Address: 194-13 1 5t inert- 81 ay City State Zip E-mail Address: CR nd iCtA'1SPtl,.JYliv • ('' Fax Number: Contitor's City of Tukwila NICET III number: Business License number:, - 69925 - Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ I15 Scope of Work (please provide detailed information): ik CL ('1 Oc a.Jh On C � CE J - 22.9 PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PE' ,• . Y BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY 40FOR THIS PERMIT. BUILDING I EliiNi "' ZED AGENT: Signature r/���//Date: ( VI Print NaItWI!k4LL4 i! g1g Day Telephone: Plan Permit App.doc / 8/22/14 TFD FP Form 8 ( fS .6401 221 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Pink 646 Southcenter Mall Permit No.: 08-S-132 Date: April 24, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe directon per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. 6 Western States Fire Protection Co. 7102 180th Ave NE Suite A-105 it Redmond, WA 98052 (425) 881-0100 (425) 881-3030 FAX Fire Protection Systems Design *Fabrication •Installation Commercial •Industrial *Residential *Institutional Special Hazards *High Tech *Defense *Hangars Retrofit *Service •Inspection *Maintenance April 17, 2008 Alan Metzler Tukwila Fire Department 444 Andover Park East Tukwila, WA 98188 RE: PINK! --Westfield Southcenter Mall Response to Tauzon Engineering Fire Sprinkler Review Letter 1. Drawings have been revised to reflect system being fed from Zone T2 and the West Riser Room. 2. Line restraint will be provided per 2007 NFPA 13 3. Washington State fire sprinklers certificate stamp will be provided. 4. Product data will be included with submittal to the City Of Tukwila. Adam Kantner Project Manager Western States Fire Protection, Inc. Dallas, TX *Austin, TX *Houston, TX *Albuquerque, NM *Decatur, IL *Denver, CO *Duluth, MN •Kansas City, KS Las Vegas, NV •Minneapolis, MN *Phoenix, AZ *Portland, OR *Rapid City, SD •Salt Lake City, UT •Seattle, WA *St. Louis, MO Ll J J 14 March 2008 Martin Sokulski Western States Fire Protection 7102 - 180th Ave NE, Suite A-105 Redmond, WA 98052 RE: Westfield Mall — Pink (Space #646) Independent Third Party Review — Fire Sprinkler System Dear Martin: Tuazon Engineering PLLC 4322 NE r Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. It appears the sprinkler system shown is part of Zone T2 fed from the West Riser Room. The following was reviewed: • Fire Sprinkler Drawings — Sheet FP1 dated 4/11/08 • Hydraulic Calculations dated 4/11/08 The documents were reviewed for compliance with the 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. Based on the drawing gridlines shown on sheet FP1, it appears the sprinkler system is part of Zone T2 in the West Riser Room. However, the vicinity map and riser room detail do not correlate with this zone. Please correct the drawing as needed. 2. Provide restraint of all branchline piping per 2007 NFPA 13 Para 9.3.6, as enforced by the City of Tukwila. 3. Provide Washington State fire sprinkler certificate of competency stamp on the drawing and calculations. 4. Include applicable product data with the permit submittal to the City of Tukwila. A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or eric@tuazon.com with any questions regarding this review. Respectfully, TUAZON ENGINEERING, PLLC Eric P. Tuazon, PE Fire Protection Engineer C KorparM.3.20013 Rga.2008 25 Western saw -week. Prom. sq.. wee., Etc 4. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: PinkNictoria's Secret 646 Southcenter Mall Permit No.: 17-S-223 Date: November 29, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. Job Number: KS0319 Report Description: Ordinary Group II Job Number KS0319 Design Engineer Adam Kanter Job Name PINK State Certification/License Number WESTESF136QF Address I 646 Southcentner Mall AHJ CITY OF TUKWILA Address 2 Job Site Southcentner Mall City Tukwila State Wa Zip Code 98188 Drawing Name FP-1.cad S �..1...................... Most Demanding Sprinkler Data 5.6 K -Factor 26.00 at 21.556 Occupancy Ordinary Group II Hose Allowance At Source 250.00 Density 0.20gpm/ft2 Area of Application 922.00ft2 (Actual 925.62ft2) Additional Hose Supplies Node Flow(gpm) Number Of Sprinklers Calculated 15 Coverage Per SpnnIder 130.00ft2 Total Hose Streams 250.00 System Flow Demand 450.15 Total Water Required (Including Hose Allowance) 700.15 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 26.93 between nodes 115 and 209 Maximum Velocity Under Ground 1.70 between nodes 1 and 389 Volume capacity of Wet Pipes 2041.49gal Volume capacity of Dry Pipes 0.75ft3 .............. suPP Node Hose Flow (gpm) Static (psi) Residual Flow (psi) (gpm) 1 250.00 140.000 20.000 I 10900.00 Available Total Demand (psi) (gpm) 139.253 I 700.15 Required (psi) 107.698 Safety Margin (psi) 31.555 J t [7:', 2 r 2008 ?uK'3'Dt9 61-7 �i5%tra�ia Contractor Number KS0319 Content Name Adam Kantner Contact Tale Project Manager Contractor Name Western States Fire Protection Phone 425.881.0100 Extension Address 1 7102 180th Ave Ne, Suite A-105 FAX 485.736.9032 Address 2 E-mail City Redmond State WA Zip Code 98052 Web -Site (y ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:02PM Page 1 Job Number: KS0319 Report Description. Ordinary Group II Device Actual Flow (gpm) Minimum Flow lgpm) K -Factor (K) Pressure (psi) Sprinkler 110 31.57 26.00 5.6 31.781 Sprinkler 109 31.10 26.00 5.6 30.852 Sprinkler 107 29.51 26.00 5.6 27.767 Sprinkler 108 29.64 26.00 5.6 28.005 Sprinkler 117 34.26 26.00 5.6 37.437 Sprinkler 106 27.68 26.00 5.6 24.438 Sprinkler 116 34.17 26.00 5.6 37.235 Sprinkler 105 27.44 26.00 5.6 24.013 Sprinkler 113 33.25 26.00 5.6 35.246 Sprinkler 104 26.49 26.00 5.6 22.384 Sprinkler 112 33.13 26.00 5.6 34.997 v Sprinkler 101 26.00 26.00 5.6 21.556 Sprinkler 102 26.05 26.00 5.6 21.638 Sprinkler 114 33.67 26.00 5.6 36.151 Sprinkler 103 26.18 26.00 5.6 21.862 te,', Most Demanding Sprinkler Data © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:03PM Page 2 Job Number: KS0319 Report Description: Ordinary Group II Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 111 12-10 P0(10-0) 66.378 115 12-10 P0(10-0) 66.001 209 12-10 P0(5-0) 40.642 217 12-10 P0(5-0) 40.004 223 12-10 P0(5-0) 35.997 227 12-10 P0(5-0) 35.677 272 12-10 52.616 273 12-10 34.786 235 12-10 P0(5-0) 48.241 236 12-10 P0(5-0) 31.304 238 12-10 P0(5-0) 48.042 243 12-10 P0(5-0) 31.110 246 12-10 P0(5-0) 45419 247 12-10 P0(5-0) 28.255 250 12-10 P0(5-0) 45.157 255 12-10 P0(5-0) 27.905 287 12-10 P0(5-0) 27.389 256 12-10 E(2-0) 44.922 261 12-10 E(2-0) 27.368 349 -0-1 T(50-0) 100.458 359 -0-1 P0(26-4) 100.366 389 3-8 BFP(-4.500) 103.384 110 8-4'A Spr(-31.781) 31.781 31.57 109 11-0 Spr(-30.852) 30.852 31.10 107 11-0 Spr(-27.767) 27.767 29.51 108 8-4'1A Spr(-28.005) 28.005 29.64 117 11-0 Spr(-37.437) 37.437 34.26 106 11-0 Spr(-24.438) 24.438 27.68 116 11-0 Spr(-37.235) 37.235 34.17 105 11-0 Spr(-24.013) 24.013 27.44 113 8-4% Spr(-35.246) 35.246 33.25 104 8-4% Spr(-22.384) 22.384 26.49 112 11-0 Spr(-34.997) 34.997 33.13 101 11-0 Spr(-21.556) 21.556 26.00 102 10-0 Spr(-21.638) 21.638 26.05 114 10-0% Spr(-36.151) 36.151 33.67 103 10-0 Spr(-21.862) 21.862 26.18 1 -6-0 S 107.698 450.15 (61� © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:04PM Page 3 Job Number: KS0319 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Eq. Length Total Length Pressure Summary Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Route 1 DR 1.049 Q=26.00 9.65 C=120 0.211434 26-8% Pf 7.128 101 11-0 q=26.00 K=5.6 21.556 Spr(-21.556) 7-0 Pe -0.779 255 12-10 27.905 E(2-0), P0(5-0) 33-8% Pv BL 1.610 Q=78.23 12.33 C=120 0.201458 1-9 Pf 0.350 255 12-10 27.905 Pe 247 12-10 28.255 1-9 Pv BL 1.610 0=104.73 16.50 C=120 0.345562 8-3 Pf 2.854 247 12-10 28.255 Pe 243 12-10 31.110 8-3 Pv BL 1.610 0=132.17 20.83 C=120 0.531499 0-4% Pf 0.194 243 12-10 31.110 Pe 236 12-10 31.304 0-4% Pv BL 1.610 Q=159.85 25.19 C=120 0.755603 4-7% Pf 3.482 236 12-10 31.304 Pe 273 12-10 34.786 4-7% Pv BL 2.067 0=159.85 15.28 C=120 0.223783 4-0 Pf 0.891 273 12-10 34.786 Pe 227 12-10 35.677 4-0 Pv BL 2.067 0=189.49 18.12 C=120 0.306529 1-0% Pf 0.321 227 12-10 35.677 Pe 223 12-10 35.997 1-0% Pv BL 2.067 0=219.00 20.94 C=120 0.400641 10-0 Pf 4.006 223 12-10 35.997 Pe 217 12-10 40.004 10-0 Pv BL 2.067 0=250.10 23.91 C=120 0.512225 1-3 Pf 0.638 217 12-10 40.004 Pe 209 12-10 40.642 1-3 Pv BL 2.067 0=281.67 26.93 C=120 0.638219 29-9 Pf 25.359 209 12-10 40.642 10-0 Pe 115 12-10 66.001 Z, P0(10-0) 39-9 Pv CM 4.260 0=281.67 6.34 C=120 0.018856 20-0 Pf 0.377 115 12-10 66.001 Pe -0.000 111 12-10 66.378 20-0 Pv CM 4.260 0=450.15 10.13 C=120 0.044889 440-11 Pf 28.395 111 12-10 66.378 191-7% Pe 5.593 359 -0-1 100.366 12fE(8-11 %2), 2fEE(4-5%), 632-7 Pv 2Ee2(5-3), fE(6-9%), CV(28-11 %), GV(2-7%), P0(26-4) FM 8.329 0=450.15 2.65 C=120 0.001714 21-10 Pf 0.092 359 -0-1 100.366 32-0 Pe -0.000 349 -0-1 100.458 2fE(16-0) 53-10 Pv MS 10.020 0=450.15 1.83 • C=120 0.000697 20-2 Pf 4.561 349 -0-1 100.458 --, 67-0 Pe -1.635 389 3-8 103.384 3LtE(16-0), BV(19-0), BFP(-4.500) 87-2 Pv UG 10.400 0=450.15 1.70 C=140 0.000437 -- 113-1 Pf 0.114 389 3-8 103.384 146-8 Pe 4.200 1 -6-0- 107.698 3LtE(25-6), E(35-1), 2EE(17-6%), S 259-9% Pv = Route 2 DR 1.049 0=26.05 9.67 C=120 0.212180 25-10 Pf 6.963 102 10-0 q=26.05 K=5.6 21.638 Spr(-21.638) 7-0 Pe -1.212 287 12-10 27.389 E(2-0), P0(5-0) 32-10 Pv BL 1.610 0=52.23 8.23 C=120 0.095415 5-5 Pf 0.516 287 12-10 27.389 Pe 255 12-10 27.905 5-5 Pv elo Route 3 DR 1.049 0=26.18 9.72 C=120 0.214210 27-4% Pf 6.718 103 10-0 q=26.18 K=5.6 21.862 Spr(-21.862) 4-0 Pe -1.212 261 12-10 27.368 2E(2-0) 31-4'% Pv BL 1.610 0=26.18 4.13 C=120 0.026593 0-9% Pf 0.021 261 12-10 27.368 Pe 287 12-10 27.389 0-9'% Pv ia. Route 4 DR 1.049 0=26.49 9.84 C=120 0.218935 28-8 Pf 7.806 104 8-4% q=26.49 K=5.6 22.384 Spr(-22.384) 7-0 Pe -1.935 247 12-10 28.255 E(2-0), P0(5-0) 35-8 Pv car Route 5 DR 1.049 0=27.44 10.19 C=120 0.233631 26-8% Pf 7.876 105 11-0 q=27.44 K=5.6 24.013 Spr(-24.013) 7-0 Pe -0.779 243 12-10 31.110 E(2-0), P0(5-0) 33-8% Pv iiip Route 6 LM ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:05PM Page 4 it Job Number: KS0319 Report Description: Ordinary Group II Diameter Flow Velocity HWC Friction Loss Pipe Type Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream DR Length Eq. Length Total Length Pressure Summary 1.049 Q=27.68 10.28 0=120 0.237457 106 236 12-10 31.304 E(2-0), P0(5-0) 11-0 q=27.68 K=5.6 24.438 Spr(-24.438) 25-2% 7-0 32-2'% Pf 7.644 Pe -0.779 Pv QD Route 7 DR 1.049 Q=29.51 10.95 C=120 0.267234 107 11-0 q=29.51 K=5.6 27.767 Spr(-27.767) 223 12-10 35.997 E(2-0), P0(5-0) 26-8% 7-0 33-8% Pf 9.009 Pe -0.779 Pv = Route 8 DR 1.049 Q=29.64 11.00 0=120 0.269354 108 227 8-4% q=29.64 K=5.6 28.005 Spr(-28.005) 12-10 35.677 E(2-0), P0(5-0) 28-8 7-0 35-8 Pf 9.606 Pe -1.935 Pv • Route 9 DR 1.049 Q=31.10 11.55 C=120 0.294583 109 11-0 q=31.10 K=5.6 30.852 Spr(-30.852) 217 12-10 40.004 E(2-0), P0(5-0) 26-8% 7-0 33-8% Pf 9.931 Pe -0.779 Pv imp Route 10 DR 1.049 0=31.57 11.72 C=120 0.302783 110 8-4% q=31.57 K=5.6 31.781 Spr(-31.781) 209 12-10 40.642 E(2-0), P0(5-0) 28-8 7-0 35-8 Pf 10.795 Pe -1.935 Pv • Route 11 DR 1.049 Q=33.13 12.30 C=120 0.331015 112 11-0 q=33.13 K=5.6 34.997 Spr(-34.997) 250 12-10 45.157 E(2-0), P0(5-0) 26-0'% 7-0 33-0'% Pf 10.939 Pe -0.779 Pv BL 1.610 0=66.80 10.53 C=120 0.150395 250 12-10 45.157 246 12-10 45.419 1-9 1-9 Pf 0.262 Pe Pv BL 1.610 0=100.05 15.77 C=120 0.317522 246 12-10 45.419 238 12-10 48.042 8-3 8-3 Pf 2.623 Pe Pv BL 1.610 0=134.22 21.15 C=120 0.546831 238 12-10 48.042 235 12-10 48.241 0-4% 0-4% Pf 0.199 Pe Pv BL 1.610 Q=168.48 26.55 C=120 0.832779 235 12-10 48.241 272 12-10 52.616 5-3 5-3 Pf 4.374 Pe Pv BL 2.067 Q=168.48 16.11 0=120 0.246640 272 12-10 52.616 111 12-10 66.378 P0(10-0) 45-9% 10-0 55-9% Pf 13.763 Pe Pv os Route 12 DR 1.049 Q=33.25 12.34 C=120 0.333196 113 8-4% q=33.25 K=5.6 35.246 Spr(-35.246) 246 12-10 45.419 E(2-0), P0(5-0) 29-4 7-0 36-4 Pf 12.108 Pe -1.935 Pv ▪ Route 13 DR 1.049 0=33.67 12.50 0=120 0.341104 114 10-0% q=33.67 K=5.6 36.151 Spr(-36.151) 256 12-10 44.922 2E(2-0) 25-3 4-0 29-3 Pf 9.980 Pe -1.209 Pv BL 1.610 0=33.67 5.31 C=120 0.042347 256 12-10 44.922 250 12-10 45.157 5-6% 5-6% Pf 0.235 Pe Pv = Route 14 DR 1.049 Q=34.17 12.69 0=120 0.350556 116 11-0 q=34.17 K=5.6 37.235 Spr(-37.235) 238 12-10 48.042 E(2-0), P0(5-0) 26-0% 7-0 33-0% Pf 11.585 Pe -0.779 Pv Route 15 DR 1.049 Q=34.26 12.72 C=120 0.352315 117 11-0 q=34.26 K=5.6 37.437 235 12-10 48.241 Spr(-37.437) E(2-0), P0(5-0) 25-10% 7-0 32-10% Pf 11.583 Pe -0.779 Pv Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter 4.87 = Factor Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 (, © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:05PM Page 5 Job Number: KS0319 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Length Eq. Length Total Length Pressure Summary .................... AO Arm -Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV AngV b BaIV BFP BV C cplg Cr CV DelV DPV E EE Eel Ee2 FDC fE fEE flg FN rr g GIoV GV Hose HV Hyd LtE mecT Noz P1 P2 PIV PO PrV PRV red S sCV Spr St T Tr U WirF WMV z Alarm Valve Angle Valve Bushing Ball Valve Backflow Preventer Butterfly Valve Cross Flow Turn 90° Coupling Cross Run Check Valve Deluge Valve Dry Pipe Valve 90° Elbow 45° Elbow 11%° Elbow 22W Elbow Flow Device Fire Department Connection 90° FireLock(TM) Elbow 45° FireLock(TM) Elbow Flange Floating Node FireLock(TM) Tee Gauge Globe Valve Gate Valve Hose Hose Valve Hydrant Long Turn Elbow Mechanical Tee Nozzle Pump In Pump Out Post Indicating Valve Pipe Outlet Pressure Relief Valve Pressure Reducing Valve Reducer/Adapter Supply Swing Check Valve Sprinkler Strainer Tee Flow Turn 90° Tee Run Union Wirsbo Water Meter Valve Cap © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:05PM Page 6 Job Number: KS0319 Report Description: Ordinary Group II Supply at Node 1 Pressure, psi > cn o f'n 8> cn `S 8 8 c`'n ti II Illi t Il t i 1 I i t l II l l 1 i ti l t l It III 1111111111 I II I t It t111111 III t I t Il IIII I I III II Li till i I t I t i I 1 I IIIII Static Pressure 140.000 .700.15 ,50.15 with hose @ 107.698 streams System demand curve 10900.00 @ 20.000, ff lnllutl flulllll 11/11/111 11111 1 1 1 1 111111111 111111111 1 1 1 1 1 1 1 1 1 1 I I 11II! 0ciliu V 9900 11000 710022M 3300 4400 5500 6600 7700 8800 Water flow, gpm Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.253 @ 700.15 System Demand 450.15 @ 107.698 System Demend (Including Hose Allowence) 700.15 @ 107.698 (Aly ©M.E.P.CAD, Inc. 441 AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:06PM Page 7 Job Number: KS0319 Report Description: Ordinary Group II [M, © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:07PM Page 8 K 13-Y VICTQIA'S s7Fol:z FIRE ALARM SYSTEM DDITI N TUKWILA, WASHINGTON S EET \UMBE SHEET TITLE EA -01 SYSTE V I\ FORIVATIO\ FA -02 TYPICAL WHI\G A\3 VOU \TI\ G DETAILS FA -03 SYSTE V CALCULATIO\S A\D SI\GLE LIKE DIAGRAM FA -0 MAI\ FLOO FR ALAS V SYSTEM. PLA\ FA -05 -EMOTE STORAGE FLOO FRE ALARM SYSTEM PLA\ • SHEET INDEX 0 Without Comments As Noted in Red ID Per The Attached Letter These plans have been reviewed by The Tukwila Fire PrEvention Bureau for conformance with current City srzr.dards. Acceptance is subject to errors and o„m:sslons which do not authorize violations of adopted standards an.; ordinances. The responsibility for the - ns rjpctnf roc.tc fntaily with t4^o rias annr, r�-:U LI l W, uGl:=JV1 w t • $ GVIJivn , w _, •c_,.. .,, Awl, 1 .) atter this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance 1s subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: �Z-13 By: 51( WRE No. nd exact a cI-e;! s or shut- down or restorattn approval. 9 v L A\D CO\i.,IT FILL C AT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. - DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE EN`/IRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMA SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 4 4 5 9 12 NORDSTROM 3 LEVELS SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL bb" A.F.F. TO TOP DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING HVAC DUCT WORKS DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1G BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2" EXTN CEILING TENANT J -BOX El_ (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END-OF-LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND macys PINK BY VICTORIA'S SECRET 1220 /SPACE #1125 w PMC CES PES:A.1fl$ P0,) ft Irey Ir) cC J (n 0\ 0' •9 C'•,1 RELEASE/REVISIONS LL DESCRIPTION 0 z a- 0 w H- 0 ,1; a<hKii W cc 0 (1) O F- 0 ca z N O w"I- QC) CD z cf)O W<Z WZ W `t WCC LL �F- G RI .-CALE: NOT TO SCALT DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 /06/ 17 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rig erved JAN 24 Me TUKWILA FIRE JOB NUMBER: 26641 --1 SHEET THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ — DEDICATED EMERGENCY FROM EXISTING MAIN FACP C CABLE C' CABLE O ai aJia GRD N L 0 0 O PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - B O 0 0 ,n (—) (+) (—) (+) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE NAC S4 NAC S3 NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSION CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) O (—) STROBE SPEAKER (+) (—) FROM PREVIOUS ADDRESSABLE 2 DEVICE HFP-11 TBI @CXDOT NO COM NC TO FAN SHUTDOWN EOLR 470 0 °O TO NEXT e ADDRESSABLE DEVICE 0 00 HTRI-R NO COM 0 NC 0 °/L TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) (—) STROBE (+) () STROBE SPEAKER SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ASHINGTON 98134 FAX (206) 628-4990 IS1 AVE_. SO., J JJ RELEASE/REVISIONS REV. BY: SWITCH + — INPUT LED TSM -1 0 °O TO NEXT e ADDRESSABLE DEVICE 0 00 HTRI-R NO COM 0 NC 0 °/L TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) (—) STROBE (+) () STROBE SPEAKER SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ASHINGTON 98134 FAX (206) 628-4990 IS1 AVE_. SO., J JJ RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE N- ciD0 2 <„-.<_1 -' c4 I J w 0 I 0 — W N 7 CCT 2 ; co z co W 0 I-1-1 «� Fa” 70 oct© O �Q 0 cf)Cr� . � UQW� � Et(j)I- o % N CI , .6§-11 CV SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 /06/17 BACKROUND PLAN PROVIDED BY: \OB NUMBER:2664 i -12 I. SHEET FA -02 A B C D E F G H I J K FIRE ALARM BOOSTER Project: PINK BY VICTORIA'S Panel: NEW BPS PAD -3 BOOSTER Date: November 8, 2017 Module/Device POWER SECRET POWER Qty SUPPLY SUPPLY Standby (mA) BATTERY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 3611 Total(A)= 15 Total(B)= 3751 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 3751 Total current ratings converted to amperes (line D x .001) 0.015 3.751 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.3124583 Add lines G and I Total Standby and Alarm AH 0.6724583 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.80694996 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: PINK BY VICTORIA'S SECRET Panel: NEW BPS PAD -3 BOOSTER POWER SUPPLY Date: November 8, 2017 Wire Resistance 2.58 CURRENT TOTAL= 3611.00 4 SET -MC -CW @l5cd SET -MC -CW @30cd SET -MC -CW ©75cd SET -MC -CW @95cd 7 ZR -MC -CW @l5cd ZR -MC -CW @3Ocd DEVICES 11 69 111 200 264 64. 111 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage SET -MC -CW @15cd 1 SET -MC -CW @30cd 5 SET -MC -CW @75cd SET -MC -CW @95cd 2 ZR -MC -CW @15cd ZR -MC -CW @ 30cd DEVICES 10 276 0 0 0 448 0 724 14 69 138: 111 111 200- 1000 264 0 69' 138 111 0 TOTAL mA=: 1387 14 Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 280 326 22.95 ( WL * 2 )* (R/ft) (Total Oct Load) (E= I * R) 24-E) 724 1.44 0.72 1.05 22.95 21.67 ( WL * 2 )* (R/ft) (Total Cct Load) (E= I * R) 24-E) 1387 1.68 1.39 2.33 21.67 CALCULATIONS PI ' VICTORIA ACP:ADD-ONS Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 4 0.0022 0.0022 0.0023 0.009 FDBZ492-HR 4 0.0635 0.0635 0.064 0.256 HTRI MODULE 5 0.009600 0.0096 0.021 0.105 0.0731 Amps 0.361 Amps Notification Appliance Circuit Detail - VOICE PROJECT: PINK BY VICTORIA'S SECRET Panel: EXISTING SPEAKER CIRCUIT Date: November 8, 2017 Wire Resistance 2.58 CURRENT TOTAL= 254.88 72 SET -MC @1!4 -WATT 3.54 SET -MC @1/2 -WATT 7.08 SET @1/4 WATT 14.14 SET @1/2 -WATT 28.29 DEVICES 72 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 254.88 0 0 0 254.88 14 1055 22.61 254.88 ( WL * 2 )* (R/ft) (Total Cct Load) (E= I * R) 24-E) 5.44 0.25 1.39 22.61 D,I HT -R 21 TSM 82-1 S2-2 75Cd 75Cd REMOTE STORAGE LEVEL 120VAC DEDICATED ( BY OTHERS) IBPSI 2S b Sv V S,V S,v S2-3 S2-4 30Cd 75Cd S V V S,V S,v S,v S,v S2-5 S2-6 S2-7 S2-8 S2-9 75Cd 75Cd 15Cd 15Cd 15Cd S,V S2-10 15Cd EOL S2 D EXISTING TENANT J -BOX S1-1 S1-2 15Cd 15Cd HT -R S1-3 S1-4 S1-5 S1-6 S1-7 15Cd 15Cd 15Cd 15Cd 15Cd S1-8 15Cd S1-9 15Cd S1-10 15Cd S1-11 15Cd EOL S1 MAIN FLOOR LEVEL SINGLE LINE DIAGRAM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 0" 17433 IST AVE. SO., SEATTLE, WASHINGTON RELEASE/REVISI CO LU Cr 0 0 DESCRIPTION SHOP DRAWINGS W I- 0 0 z I - w CSC 0 w CI) C/) Ci 0 F- > - CO z 1. N Z co p wT cn u)O �O Lu < z _ W< z� U� LuCC r OH 0 N cC c3 l LU LU 0 C-0 06 z 0 0 F- 00 CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1/06/1 7 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 26641-1 I SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved " / TO EXISTING TENANT JUNCTION BOX TO EXISTING TENANT _ — JUNCTION BOX E--_ -: TO EXISTING TENANT JUNCTION BOX S,V D I HT -R1 S1-1 15Cd S1-3 15Cd SO S1-4 15Cd/ D HT -R TSM /N iI • S S1-2 15Cd s V S 3 CCd J 0 r, IHT—R-' ITSMI S1-8 15Cd S1-5 15Cd S1-9 15Cd I tJ S2-4 75Cd siv FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. ( s.v S2-5 75Cd S2-6 S 75Cd LI S1-7 15Cd o—S V CEO S2 S2-10 15Cd S1-6 15Cd_ c S S1 -11i; 1594 S1-10 15Cd EOL S1 S2-8 15Cd S2-9 15Cd • MAIN FLOOR FIRE ALARM SYSTEM PLAN 141 N) U` 0, 00 N 174.:7 ISi AVE. SO., SEATTLE, WASHINGTON RELEASE/REVISIONS CO > w DESCRIPTION z Q 0 0 w F - Q 0 z <K<K,, CL W i T j wow- ci) Ft ci) 0 (no G O 03cc cr) < WQ Uz LU J Le.)LL rI ca CC © O N 0LL z �CALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 /06/ 17 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 266411 -1/ SHEET `` \ FA -04 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved J WEN ■ ■ ■ie■V■ ■A■ ■O■ ■ai■ ■!X■ ■ »■N ■!■ F■R■VENEW■V■V■ 0 LL N N I N LL N ct N N N 2 0 U. N N EVE EVES 2442F O'H 2442F F 10'H 2442F F 10'H 2442F F O'H 2442F F O'H z 1 J J D HT -R ITSMI REMOTE STORA GE DN TO EXISTING TENANT c JUNCTION BOX L S2s S 75C L co- S S2- S 75C RR 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M 10'H M# 2442M 10'H M410'H 2442M M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M 1 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M *1 Fl -i Rf 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M 1, `10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M((,� M# 2442M M# 2442M M# 2442M ]]��llL {III -It iiII (� 1 it 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M o-S,V ULU uu sv REMOTE STORAGE FLOOR FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. IST AVE. SO., SEAT1LE, V N) J Z O_ w CZ LU u) W J LU CZ CO w CD 0 DESCRIPTION SHOP DRAWINGS w I- 0 N c0 0 I— W L a T oz Wow U) I W33) � o �o Ci wdz_ O �L_ Ucz� > >— w F °T z o NCL COEL >CC w CC0 O Li_ w 0O D w CALE: 1 /4"=1 '0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 /06/17 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 26641 —12 r SHEET �y FA- 0 5 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved t, .:9 FIRE ACARINE SYSTE TUKWILA, WA.HINGTON SHEET INDEX SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALAaM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLAN Per The 11 :., `.. ;'•r +.'. _^Ii .. .t:' . ..,_ :,::..'!ie Fire ;I: :'' _;I ; c... :: t rl_17eflt city C'I rurs and ;, ,..c`t O: ;so: Ji:i i il. 'CJi�ii�'fj5 rf adopted r:. ii(`•i •Sih .ty for the h_ + :; % r;:;u atter a rF I;uant approval. Tu - .0 ..._ test and inspection by 61-2 Cy: SIC CUKWILA FIRE DEPARTMENT. Please call: 575-440Z and give this job and exact address for shun Down or restoration aoDroval: .1 NOTICE A completed, signed, Tukwila Fire Department Pre-test C;.rtificate must be presented in the Inspector prior to -:s nmencement of Acceptance Testing of any Fire Alarm aid Detection Systems. Failure of test will result Re -inspection Fee and I (ination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR. W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART„ ..... - . NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. _0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE ' 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE,. FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED.' IN` DIRECT. AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. - 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND .760 OF :NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES ,SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, 'WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL: BE MOUNTED AT 48' A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS' WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE. AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR. TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. . 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT ' CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH .A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND. RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 5 4 8 1 2 1 SYMBOL DESCRIPTION SYMBOLS ,LEGEND MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP I BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP ® INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD LINEAR BEAM I N SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT SMOKE p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING gL C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXT. FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM sc FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -HMC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. L FIRE ALARM STROBE C (CEILING MOUNT) ZR -MC -CW' SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX WI 1G RING 80" A.F.F. TO BOTTOM U.O.N. Q FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 11/2" EXT. TO BOTTOM FIRE ALARM BID STROBE WP (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD El MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A: N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A NSA BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A 1,0 oo 0` O 0' 0' O0. CV 0 0 cV >G Q U uJ F- - . , 2000 Tukwila Fire Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved` 0 z • SCALE: 1/8'1=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: ,OB NUMBER:54535 } SHEET FA-Ol , THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE. SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AIR DUCT 6-10 DUCT EQUIVALENT DIAMETERS DUCT DETECTOR LOCATION o TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC END OF LINE DEVICE (3.6K 1/4W) SUPERVISED SWITCH it 0 M GROUND_ 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 0 HTRI—R 4110 STATUS LED co 0 N.O. I` 0 CO 0 COM N.C. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL L EL KALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH- C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING-'\ TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE L} -AC POWER SOIJRCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING ;' TO NEXT ADDRESSABLE DEVICE` .p.0 STOP IF LAST DEVICE FROM XLS CONTROL PANEL ORT) PREVIOUS ADDRESSABLE DEVIC) RELAY CONTACTS (4.0A @ 125VAC) (4.0A B 30VDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 ' AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. i + 000 12345.6. HCP TB2I00 6 5 O 0 +b 4321 0 0 END OF . LINE Z I — DEVICE ..r 0 (3.6K 1/4W) — / SUPERVISED I SWITCH . GROUND ----- NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. �t- O HTRI—D STATUS LED co 0 0 NOT USED (0 0 0 -TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABEL KALE (FIRE SUPPRESSION SYSTEM INTERFACE) - 0 GND N AC II 0 0 PAD -3 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX ,'1+1- 1.2+ 2- 2 NC. C NQ •t +.- t.- + - +- raIMITIMIMI611a 24K I`'"II` 10110-IiM TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE r FRONT VIEW 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE _ DEVICE LOOP NOT USED REMOTE DEVICE LOOP FROM XLS CONTROL PANEL OR (-F), PREVIOUS ADDRESSABLE DEVICE (-)> 0 a a a TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL EARTH GROUND ->(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE FROM REMOTE POWER SUPPLY ('S' CABLE) END OF LINE DEVICE FROM FACP 3.6K 1/4W) . (VOICE CIRCUIT) S('V' CABLE) UPERVISED 1 SWITCH 2 NAC -4 2 NAC -3 NAC -2 ?NAC -1 SCALE NONE (-) STR❑BE) SPEAKER (-) (-) (--) (-) STROBE • '1 O-) ( ) STROBE SPEAKER SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 4S DEEP BOX W/ 1 -1/2 - EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE �TO NEXT . DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. HFP-11 SMOKE DETECTOR - . FROM PREVIOUS ADDRESSABLE DEVICE OR POKER SOURCE DATA IN (-) >- DATA IN (4-) > DEVICE IS USTED FOR AIR VOLOOTY APPLICATIONS OF 300-4000 HAIN WHEN USED IN CONJUNCTION ICH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW > ( ) DATA OUT 1 > (+) DATA OUT )r TO NEXT DEVICE HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID -- CEILING HARD LID _\ SPEAKER SUPPORT TLE - - BRIDGE c C/3 a cc z CO (T O I- CD (/) UJ F- W (I) cn W cn f'0 CD 0• ' 00` CD N X., CV CV '0' CD CV _I LU F- •. WITH 1-1/2' EXTENSION N —CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTION BOX MOUNTED ON \ CEILING FLEX \ JUNCTION BOX 6OUNTED AGAINST '- CEILING SUPPORT 0 0 SMOKE DETECTOR --- SMOKE DETECTOR MOUNTING TO NEXT DEVICE ----CADDY BAR SUSPENDED ILLUMINATED CEILING co co cr cf) 12Z w 04,e- 0 0 DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI BACKROUND PLAN PROVIDED. BY: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET . ;-. • ;•';. ' • • 1 1 LI I „- I EOL 18.3 3VE A:2 " ALE V A 7 CIE.. . , . N. 7 0 .X , . : .. V N - , -N. 11 V N. 75 1;11 II r- : I .1 t P-12 . 1 i•\.1 ....:, • 2S,2V i rf- 'I' R' ; s 1:7=.: '4, rl L _ A 30 JI CORR:DO', ; .-;. '420 2S,. V 1z I 30 • :I”. ,./151.1 In 0 c:=>— 2S,2V c;>--2S,2V --„-_,7 __--_-1 -P-1, ., I 1.:V..ifF 501.11` Ft,.., -F 14.0,111illi 1.410:4' ill, SI,, 2S,2V. ME NS E 2S .., .? +11-1.Rli 4TIFITIEREIHRIPFEMTETITIPIRDIPTARTEDIRSERBI \ . 15_ V WON -1E NS 0-720 104- -I ITIATCJ-; • ::-.NORTH r [1 • A EIJA C E T T C.) r; m 1:3 SALES FLOCRi • '; t --- --- --,-;;72t-..i.7 r -,- . . . • 1117;ff47gq.- TUDIJ ittr; ---- –2S,2 ry F r -4-1H' 1--c- 11 -7:47-IL „FAiligiskLIVAIX93. , BAITTRENVARIPI A I ' „ 1 I I 1. R0017,4 42 SALES FLOCP 2S,2V ELICIt SC:FF•T-F H.TI.1 FACE Cf 12.1:0 0 L s' FIT DUG ItSO,rI A F.) V E 9'- PC q -T; - F "!J 1.11, PINK WESTFIELD SOUTHCENTER MAL SCALE 118':V I P -2c; • czwyer TAP. • ' • • • • • . , • , P 2 : - - - E c:damr, 11 I;; • 4' 47Tc 727-1 26 --CEILAT T3 NATO:: OF T.4.6D A' • AFACr fe. 1: -..;OM F: SALES FLOC)" a- El Irm ..- . 1)(1 • ..y.,- _ -,;,1-(&_.,-/x7L-i•FzTol..3.-:.ff-21-..-ffri:?, :i ---:i: LIE`ift.,247:11Triffileitt.H.1.1111115IA: _____ •'• C 4 FLAG NOTES: Copyright FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. j i•; ! i : • : • i I • I! . : 1! • ; • ' • . • .• . 2006 by Guardian Security Systems, Inc. All: Rights Reserved ND 0' CO 174.3 ST AVE. SO.; SEATTLE, WASHINGTON CI) RELEASE/REVISI LLJ DESCRIPTION 0 0 co w ct 6ALE: 1/8"=1' DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01/08 BACKROUND PLAN PROVIDED BY: ._10B NUMBER:54535 SHEET FA -03 NORDSTROM \ FE I NORTH BEN PARFUN4ERIE SUN M TiON Si PINK! WESTFIELD SOUTHCENTER MALL SCALE MN' S,2V 2S,2V 2S,2V a 11 110 75 75 30 C 30 15 15 30 S,2V. • El • a 15 S,2 V S,2 V 30 . 75 EOL -S1 • 18.33V S,2V • LLO LflUJ < c 2S,2 V -<=3 D 1 PUBLC CORR. Cr) Cf.1 Ui D 0 LID LID41. LID " a a 21 21 • 2I 0.,4. 21 RISER DIAGRAM LL! Cf Lii Cr. . : 5_5 CL I 1)] ;1,%\ • Ui ft.; :SD F--- •.- SYSTEM CALCULATIONS • ; - BATTERY SIZING CALCULATION ; I : Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: PINKS! Date: May 6, 2008 !Wire Resistance 1.62 CURRENT TOTAL= 1342 CIRCUIT:!S1 QTY Device Type i I i ; 1 f , 1 ' f Alarm Current i Alarm Total 1 Wire Size ! Wire Length i . Voltage at EOL i Circuit Total 1 1 ' . • • , . 1 SET -MC @15CD 641 641 4 SET -MC @30CD 981 3921 3 1SET-MC @75CD 1751 5251 1 SET -MC @110CD 2331 2331 iTOtal Wire Resistance ( R ) ( WL * 2 )* (R/ft) - iTotal Device Load, Amps (I) 1.62' 1.34! , , 1 I : •cTotal Cct Load) ! 1 i . Voltage Drop ( E ) 2.171 ' , I 0 :SET-HMC-C@115CD 3181 01 0 !SET-HMC-C@177CD 445! Oi 0 !SET -HMC @135CD 318; 01 0 SET -HMC @185CD 445 0 2 Z-MC@15CD;64! 1281 1 -(E= * R) lEOL Voltage ; . i I i ; • - --- --- -- • - i . _ (20.4 - E) •I .,.„ ..... ... i . t ! i I t t•i i t .. 0 23 A i i I 18.23' 0 IZ-MC@30CD 931 18'. 01 ISET-MC-CW@110CD Oi DEV10ES=1 1 TOTAL mA=, 1342! 12 ; 500 18.225961 1342 Notification Appliance Circuit Detail PROJECT:1WESTFIELD SOUTHCENTER MALL Panel: PINKS !Wire Resistance ,2.58-, Date: May 6, 2008 CURRENTTOTAL= 16.2 CIRCUIT: i SPEAKER CIRCUIT ' - QTY Device Type 'Alarm Current Wire Alarm Total I Size 1 VVire Length Voltage at EOL Circuit Total . 1.8i 1Total Wire Resistance ( R ) 1 258 0! o -2 ) * (R/ft) - - 0 . . 0 I Total Device Load, Amps (I) , 0! •0! 1 •,•i .FVolt,age Drop ( E ) 0 - 0 • 0 ; 01 - 0 - i - . ; ; .; t i . i i - I . , ; 1 1 lE; 0; L(EV-oll Voltage - , , , o 01 01 I ! - i i 1 - (20.4 - E) , i 1 t 20.361 .._ (Total Cct Load) 0.02! I • . 1, 0.041 0 01 0 • 0 0! ; i i .„ 1 , 0 • _ I 0' - - 01 - , -_ 1 •, ; m = I - , 2 . DEVICES=19 TOTAL A -16.21 - 14 .. -1 500 _ ..--1 " 20.358204 , i , -,- 16.2 • VOLTAGE DROP CALCULATION • ; ;• ; • , • ; • i;•1' '11v • . : • 11!' • • • •, } RELEASE/REVISIONS LLJ cr DESCRIPTION Lii FLii- 0 z CO CO _J 2 Z W 0 CC W z z t w o <es cc H F- D 0 LL1 F - w w z cr) z 0 Lu cf) DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01/08 . BACKROUND PLAN PROVIDED BY: NUMBER: 54535 • Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved: . , PINK! PINK! .. , FACP ADD ONS ,.. ,• SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations • , , „, . Current Load: Standby: Alarm: Current Load: Standby: Alarm: S Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 • 0.0022 0.0022 0.0023 • 1 „ 1 , 1, AD2-P ' , . 4 0.0635 0.0635 0.064 0.256 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R: HTRI-D ICP -B6 ' 5 0.009600 0.0096 0.021 0.105 SET -MC @15CD SET -MC @30CD SET -MC @75CD SET -MC @110CD 1 0.064 0.064 . 0.001600 0.0035 4 0.098 0.392 , '1 0.005 3 0.175 0.525 1 0.233 0.233 SET-HMC-C@115CD SET-HMC-C@135CD SET-HMC-C@185CD ZR -MC @15CD _ ZR4./IC @30CD HCP . 0.318 0.318 0.0731 Amps 0.361 Amps 0.445 2 0.064 0.128 Standby! Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours , 0.098 1 , , 0.0015 Alarm CUrrent Load: 0.361 Amps For 5 Minutes= 0.030 Amp -hours 0.03 Amps 1.372 Amps . , . , I , 1 Si! , :;• . , 1 . 25% Derating= 2.231 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours ,, ,; • , Alarm Current Load: , 1.372 Amps For 5 Minutes= 0.115 Amp -hours. , Total System Current Load: 2.231 Amp -hours 25% Derating= 1.044 Amp -hours •i ! .• Battery Pair to be Used: 12VDC Amp -hours 7AH . ; • , • • : • i ; ';. - Total System Current Load: 1.044 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH , • ; - BATTERY SIZING CALCULATION ; I : Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: PINKS! Date: May 6, 2008 !Wire Resistance 1.62 CURRENT TOTAL= 1342 CIRCUIT:!S1 QTY Device Type i I i ; 1 f , 1 ' f Alarm Current i Alarm Total 1 Wire Size ! Wire Length i . Voltage at EOL i Circuit Total 1 1 ' . • • , . 1 SET -MC @15CD 641 641 4 SET -MC @30CD 981 3921 3 1SET-MC @75CD 1751 5251 1 SET -MC @110CD 2331 2331 iTOtal Wire Resistance ( R ) ( WL * 2 )* (R/ft) - iTotal Device Load, Amps (I) 1.62' 1.34! , , 1 I : •cTotal Cct Load) ! 1 i . Voltage Drop ( E ) 2.171 ' , I 0 :SET-HMC-C@115CD 3181 01 0 !SET-HMC-C@177CD 445! Oi 0 !SET -HMC @135CD 318; 01 0 SET -HMC @185CD 445 0 2 Z-MC@15CD;64! 1281 1 -(E= * R) lEOL Voltage ; . i I i ; • - --- --- -- • - i . _ (20.4 - E) •I .,.„ ..... ... i . t ! i I t t•i i t .. 0 23 A i i I 18.23' 0 IZ-MC@30CD 931 18'. 01 ISET-MC-CW@110CD Oi DEV10ES=1 1 TOTAL mA=, 1342! 12 ; 500 18.225961 1342 Notification Appliance Circuit Detail PROJECT:1WESTFIELD SOUTHCENTER MALL Panel: PINKS !Wire Resistance ,2.58-, Date: May 6, 2008 CURRENTTOTAL= 16.2 CIRCUIT: i SPEAKER CIRCUIT ' - QTY Device Type 'Alarm Current Wire Alarm Total I Size 1 VVire Length Voltage at EOL Circuit Total . 1.8i 1Total Wire Resistance ( R ) 1 258 0! o -2 ) * (R/ft) - - 0 . . 0 I Total Device Load, Amps (I) , 0! •0! 1 •,•i .FVolt,age Drop ( E ) 0 - 0 • 0 ; 01 - 0 - i - . ; ; .; t i . i i - I . , ; 1 1 lE; 0; L(EV-oll Voltage - , , , o 01 01 I ! - i i 1 - (20.4 - E) , i 1 t 20.361 .._ (Total Cct Load) 0.02! I • . 1, 0.041 0 01 0 • 0 0! ; i i .„ 1 , 0 • _ I 0' - - 01 - , -_ 1 •, ; m = I - , 2 . DEVICES=19 TOTAL A -16.21 - 14 .. -1 500 _ ..--1 " 20.358204 , i , -,- 16.2 • VOLTAGE DROP CALCULATION • ; ;• ; • , • ; • i;•1' '11v • . : • 11!' • • • •, } RELEASE/REVISIONS LLJ cr DESCRIPTION Lii FLii- 0 z CO CO _J 2 Z W 0 CC W z z t w o <es cc H F- D 0 LL1 F - w w z cr) z 0 Lu cf) DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01/08 . BACKROUND PLAN PROVIDED BY: NUMBER: 54535 • Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved: . , C7 Without Comments L7. As Noted in Red Per The Attached Letter These pians have been reviewed by The Tukwila Fire Bureau for conformance with current City -;dards: Acceptance is subject to errors and -, :sions which do not authorize violations of adopted ,ards and ordinances, The responsibility for the i uaCy: of design rests totally with the designer. tlotis, deletions or revisions to these drawings after •-' e will void this acceptance and will require a i;:=?or�liLtai of revised drawings for subsequent approval. a1 acceptance is subject to Heid test and Inspection by f ,r l'Clkwila Fire Prevention Bureau. s UKWILA FIRE DEPAR E TIr P:eaSP r1206-575-4407 and give this Fire Permit No. :trod • ac't address for shut- down _ down or restoration appt:oval. 111111;::,:,:�:=:=: ,.r,1111;14% Corrugated stainless steel hose with stainless steel brat aveilab€e in 2', 3',4',5' & 6' legnths . • 144 • • / Multi -Port Bracket - Adjustable Hub TOP BEAN/ C—CLAHP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL. RING F.lexhead omCrie.rciai Ceiijrig Unit • T -Bar belling installation - Model #2024,2036,2048,2060,2072 STEEL JOIST/TRUSS HANGER DETAIL DO NOT ROUTE ANY PIPING OVER ELECTRICAL EQUIPMENT ELECTRICAL CLOSET PINK 2 iz'v PINK 3 TRANS #4 TRANS #5 ADJACENT TENANT -. N.I.C. ter p . PIRB PROM@ • SP R$NKt.@R >sVBTeNI>r 8 el - John J. Abel a 9 '80.0691 e c . 't " a C Pre - , Ino. • BREAK AREA FIRE SPRINKLER HEAD PLAN BOUT/GI TER IAA. 1100 SOMME/MA MALL 10010.1. WA (MO VICINITY MAP Design per NFPA 13 - Ordinary Hazard Group 2 (Retail) ATI materials to tobe bewithin new, U.L. listed andof NF.MFPA, approved All heads to be at least 6' apart with no obstructions Instaation full compliance International requirements, and the local A HJ Fire Code, manufacturer o 59 — Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 - White CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425)481=7669 moue 16.2111100111 20001 NM IUD OWT0MCE 150 KEY PLAN Pink Victoria's Secret L-c-53TSouthcenter Mal Space 1125 Tukwila, WA 98188 DRAWN: • SCALE: VICINITY MAP (Suite# 646) SCALE: NT General Notes 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system pipirzig and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. FILE COPY WEST RISER DETAIL HYDRAULIC REFERENCE O TI. NOT TO SCALE MATCH MALL EXISTING 4" MAIN ZONE T-1 12-11% 2-11 -5 9-6 9-6 7-11 8•-8• 1 rk4' P-1 I 447 3 itI pry i.I r-6- ir Pee ir; ��/� ' C�O�� t 1 3.412ic - j 0-4%.. iI \ Cki ft: 0O ° Ir �0,NI +'1 ii el l4 iOtt" 240 c ® WC -22 ct h '40NSAL=-S 17.0 - AC --2 9 9 1-3 1 6•-8- P-26 r. SALES FLOOR Nri 11-0' P•28 -1 0 00 14 6=1 11=1`) M111 3213 » PINK Remote Area: Retail # 646 CALCULATION DESIGN CRITERIA: STANDARD NFPA # 13-2007 OCCUPANCY mass ORD HAZARD II MAX COVERAGE per HEAD 130 Ft= DENSITY .20 GPM / FN for 925.62 Ft' SPRINKLER Reliable Model G4A WATER FLOW INFORMATION*: STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER. SYSTEM REQUIRES: 450.15 GPM © 103.4 PSI ' At time of Design 11`-0" CLG.=38.5% AREA REDUCTION PP CT C Weld stamps must be inspected before pipe is hung. o not paint piping viler hydrostatic test approval. • nDam9 uoquene.td n 1 I!M)IV1J ILL i(q uoI}cadsui cue isal p; I.=, of loafrins sl acueld000e ieurd ]enoJdde}uan�c ;';:s .; ° ,,;;� pc:l ,, '110 l tlitgnsaa e aa;nb9..1 `. 1 , p t#3 `''� `Suo 1 ppv 'lit •._. - - �', � •: 4oenhepe Gill 'C; PI s; ietxle;s pG-4dopr3,;> L ,{ ;;i 31.IopS1wo •SpJ13pLI }s A;IO'i -.•• :_ ;1. Ii; -fil+s UOl;UatOJCJ "'.1I :I:' ! 1 '_ic: G`, :a'cq sueld GSSU ice:; ▪ 1 P0'43 -i1 cU_( gad p`4uN sV S,UGWWO j }i3Oq M D TUKWILA FIRE DEPARTivitill. Please call: 575-440Z :nd give thls job No. O3-S-IJD- and exact address for shute G.)‘ -tin or restoration approv l N 9 I .I • n itt CI 4 era rag NAT: T to I 10,1' P-28 • uta 11•-0- P-28 I 11 41'4 1-- 6•-4' P-25 rC 02 I 1t-o.—I' I P•26 Ii z.c 0 CO 3',4� i37h/s'>9 0 �`V \ SALES FLOOR ,` 4.,�N �� n___ o 90 1p-(/2 I!. 1 i., ,,I CO +°• ��' 1 1+�� -0/2 -8 ~L Q1M1 0Y�r� IJ 1 h 4t) I �l� eho 13 EXISTING 4" MAIN ZONE T-1 :::TYPICAL FLEXABLE SPRINKLER CONNECTIOW FLEXHEAD MOUNTING BRACKET PIPE NIPPLE " SPRiNKLER BRANCHLINE Corvi\i6fli\i6 HOSE IN STANDARD LENGTHS SUSPENDED T -BAR GRID CEILING TILE SPRINKLER HEAD NOT TO SCALE KWIK BOLT 1/4' EMBED LENGTH) FIG. 10QO "FAST CLAMP" SWAY BRAC E ATTACHMENT LATERAL UNE RESTRAINTS NON-THREADEO BRACE PIPE F10. 4A PIPE CLAMP FOR SWAY BRACE NC•THREAD SWIVEL SWAY BRAC E ATTACHMENT 3/8* KWIK BOLT (2 lg. EMBED anarre n. LATERAL BRANCHLINE RESTRAINT TEA NON -THREADED BRACE PIPE BRACE PIPE LATERAL BRANCEILINE RESTRAINT NOT TO SCALE SALES FLOOR 0 4t l P-28 CO 11to- !1 P -26_ j1 5-41A W2 Ordinary Group11.0.20Qpni/ft2 for 922.00ft2 FIRE SPRINKLER SYSTEM Hanger No. 07C HILTI Kwik Bolt III Cut Rod Lgth Rounded to Nearest Inch Rod Coupling All Thread Rod s' Swivel Ring Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'X Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE • ARCHITECT: PINNACLE CONSTRUCTION CONTRACTOR: SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE DESCRIPTION DATE SYM. SIN QTY. SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE R3615 10 5.6 Pendent Chrome 155°F F1FR Semi -Recessed APPROVAL: CITY OF TUKWILA HYDRAULIC REFERENCE POINT R5415 46 5.6 Pendent White 155°F Reliable G4A Concealed CONT. NO.: KS0319 Total = 56 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE 04122/08 Western States Fire Protection Company 7102 18051 AVE NE, STE A-105 - REDMOND, WA - 98052 WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALB/XIUERCITE /ALAIN/ DALLAS/ DECATUR /DENVER / DULUTH/HOUSTON /KANSAS CITY LASVEGAS / PAIMEAPOUS/ AWIENIX/ PORT1AND !RAPID CITY / ST. PAUL /SALT LAKE CM /5F-ATTLE • Phone: 425-881-0100 Fax 425-881-3030 PINK 646 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SHEET FP1 OF VICINITY MAP (Suite# 646) SCALE: NTS General Notes 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. WEST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE 9,-o. MATCH MALL EXISTING 4" MAIN o 1"\" h? o• ;`l P-26 1l. -o. CL rn :-\;:411 N 02 c)::°-:kv:f4:111-21 ® ®i>0 EMI =2 IC9 =1 t® to 1621 PINK Remote Area: Retail # 646 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM / Ft' for 925.62 Ft' SPRINKLER Reliable Model G4A ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER. SYSTEM REQUIRES: 450.15 GPM © 103.4 PSI . At time of Design 11'-O" CLG.=38.5% AREA REDUCTION P-26 Fe -4' P•28 0 P-26 ji I 11* -0' 1 P-26 L1P-120' Ij EXISTING 4" MAIN 1-31/2 Ordinary Group II.0.20gp:nlft2 for 922.00ft2 FIRE SPRINKLER SYSTEM 1/8"=1'-0" F� TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD k: CEILING TILE FLEXHEAD DETAIL NOT TO SCALE FIG.909 SWIVEL SWAY BRACE FITTING 3I8' KWIK BOLT (21M' EMBED LENGTH) FIG.1000 "FAST CLAMP' SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE 3�57�911 FIG.4A PIPE CLAMP FOR SWAY BRACE FIG.909 NO -THREAD SW NEL SWAY BRACE ATTACHMENT 319' KWIK BOLT (2 1W EMBED LENGTH) 9 i a LATERAL BRANCHLINE RESTRAINT I a c I NON -THREADED BRACE PIPE BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III N / HILT! Kwik Bol II / ` Drilled Anchor r/L► �, / / Y Cut Rod Lgth Rounded to Nearest Inch Rod Coupling —� All Thread � Rod Swivel Ring Pipe Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE 3-S/32_ z w z 0 Adam Kantner 2 a w m 0 PINNACLE CONSTRUCTION INC. CONTRACTOR: SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE HYDRAULIC REFERENCE POINT t R3615 10 5.6 Pendent %Z' Chrome 155°F F1 FR Semi -Recessed APPROVAL: CITY OF TUKWILA R5415 46 5.6 Pendent White 155°F Reliable G4A Concealed CONT. NO.: KS0319 Total = 56 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 06/19/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA- 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE /AUSTIN /D LLLAs/ DECATUR !DENVER / DULUTH /HOUSTON /KANSAS CITY LAS VEGAS/MEI EBPOLIS /PHOENIX/PORTLAND/ RAPID CITY / ST. PAIL/SALT LAKE CRY/SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 PINK 646 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SHEET FP1 OF 1 646 SOUTHCENTER MALL ASSOCIATED PERMITS 18-F-026 08-F-179 17-S-223 08-S-132 4401% CITY OF TUIWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION / (P lvc King Co. Assessor's Tax No.: Site Address: 77 f %774/ Suite Number �• L�—fyoor: Tenant Name: \ Yl V C- Y\& SGcxe' New Tenant? ❑ - Yes ❑ - No Property Owner's Name: \Jj r ti Sri �� j✓ �jr'' Mailing Address: 2 601 Pty it Man - / 1,z1o)1 a, L9 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: CrisVN•e_. D \c Day Telephone: Company Name: br 1 F Y F"DCt17OY? / In G Mailing Address: 1r) F,X \.2.-\\> • 1 , l \A r -C CO -w� 1%0%2_ ity E-mail Address:k5 C 'r ,rt>. C C)YYl Fax Number l! 1 Contractor's City of Tukwila NICET III number: q7 • OSen • C& Business License number: B vs • Q g9 6- g! 2. Total number of new/relocated devices or sprinlder heads: 51 Valuation of Project (contractor's bid price): $ `01 • Scope of Work (please provide detailed information): M6.. t- 1neos PERMIT APPLICATION NOTES Vahre of Construction — In all cases, a value of construction amount should be entered by the applicant This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Print Name: Plan Permit App.doc OR AUTHORIZED AGENT: CA Date: 11•15.r7 4SV x 7 J7SO77 Day Tom: 4/25• 171/' 70679 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** (� � RAY ^ n I ^ King Co. Assessor's Tax No.:g2OZ r 00) 0 Site Address:1220 �/1 l.'(,AY h'I,at Suite Number: ) Floor: Tenant Name: V (C 1 U CU C k New Tenant? ❑ - Yes No Property Owner's Name:" C G I C Mailing Address: CONTACT PERSON -if there are questions about the submittal. �/l Name: � int �' ' I Day Telephone: 2Z-(Q5q Company Name: U 1 / I L'i i JCk}(f\74-I (1'e41(l S' City State Zip Mailing Address: 194-13 1 5t inert- 81 ay City State Zip E-mail Address: CR nd iCtA'1SPtl,.JYliv • ('' Fax Number: Contitor's City of Tukwila NICET III number: Business License number:, - 69925 - Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ I15 Scope of Work (please provide detailed information): ik CL ('1 Oc a.Jh On C � CE J - 22.9 PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PE' ,• . Y BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY 40FOR THIS PERMIT. BUILDING I EliiNi "' ZED AGENT: Signature r/���//Date: ( VI Print NaItWI!k4LL4 i! g1g Day Telephone: Plan Permit App.doc / 8/22/14 TFD FP Form 8 ( fS .6401 221 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Pink 646 Southcenter Mall Permit No.: 08-S-132 Date: April 24, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe directon per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. 6 Western States Fire Protection Co. 7102 180th Ave NE Suite A-105 it Redmond, WA 98052 (425) 881-0100 (425) 881-3030 FAX Fire Protection Systems Design *Fabrication •Installation Commercial •Industrial *Residential *Institutional Special Hazards *High Tech *Defense *Hangars Retrofit *Service •Inspection *Maintenance April 17, 2008 Alan Metzler Tukwila Fire Department 444 Andover Park East Tukwila, WA 98188 RE: PINK! --Westfield Southcenter Mall Response to Tauzon Engineering Fire Sprinkler Review Letter 1. Drawings have been revised to reflect system being fed from Zone T2 and the West Riser Room. 2. Line restraint will be provided per 2007 NFPA 13 3. Washington State fire sprinklers certificate stamp will be provided. 4. Product data will be included with submittal to the City Of Tukwila. Adam Kantner Project Manager Western States Fire Protection, Inc. Dallas, TX *Austin, TX *Houston, TX *Albuquerque, NM *Decatur, IL *Denver, CO *Duluth, MN •Kansas City, KS Las Vegas, NV •Minneapolis, MN *Phoenix, AZ *Portland, OR *Rapid City, SD •Salt Lake City, UT •Seattle, WA *St. Louis, MO Ll J J 14 March 2008 Martin Sokulski Western States Fire Protection 7102 - 180th Ave NE, Suite A-105 Redmond, WA 98052 RE: Westfield Mall — Pink (Space #646) Independent Third Party Review — Fire Sprinkler System Dear Martin: Tuazon Engineering PLLC 4322 NE r Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. It appears the sprinkler system shown is part of Zone T2 fed from the West Riser Room. The following was reviewed: • Fire Sprinkler Drawings — Sheet FP1 dated 4/11/08 • Hydraulic Calculations dated 4/11/08 The documents were reviewed for compliance with the 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. Based on the drawing gridlines shown on sheet FP1, it appears the sprinkler system is part of Zone T2 in the West Riser Room. However, the vicinity map and riser room detail do not correlate with this zone. Please correct the drawing as needed. 2. Provide restraint of all branchline piping per 2007 NFPA 13 Para 9.3.6, as enforced by the City of Tukwila. 3. Provide Washington State fire sprinkler certificate of competency stamp on the drawing and calculations. 4. Include applicable product data with the permit submittal to the City of Tukwila. A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or eric@tuazon.com with any questions regarding this review. Respectfully, TUAZON ENGINEERING, PLLC Eric P. Tuazon, PE Fire Protection Engineer C KorparM.3.20013 Rga.2008 25 Western saw -week. Prom. sq.. wee., Etc 4. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: PinkNictoria's Secret 646 Southcenter Mall Permit No.: 17-S-223 Date: November 29, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. Job Number: KS0319 Report Description: Ordinary Group II Job Number KS0319 Design Engineer Adam Kanter Job Name PINK State Certification/License Number WESTESF136QF Address I 646 Southcentner Mall AHJ CITY OF TUKWILA Address 2 Job Site Southcentner Mall City Tukwila State Wa Zip Code 98188 Drawing Name FP-1.cad S �..1...................... Most Demanding Sprinkler Data 5.6 K -Factor 26.00 at 21.556 Occupancy Ordinary Group II Hose Allowance At Source 250.00 Density 0.20gpm/ft2 Area of Application 922.00ft2 (Actual 925.62ft2) Additional Hose Supplies Node Flow(gpm) Number Of Sprinklers Calculated 15 Coverage Per SpnnIder 130.00ft2 Total Hose Streams 250.00 System Flow Demand 450.15 Total Water Required (Including Hose Allowance) 700.15 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 26.93 between nodes 115 and 209 Maximum Velocity Under Ground 1.70 between nodes 1 and 389 Volume capacity of Wet Pipes 2041.49gal Volume capacity of Dry Pipes 0.75ft3 .............. suPP Node Hose Flow (gpm) Static (psi) Residual Flow (psi) (gpm) 1 250.00 140.000 20.000 I 10900.00 Available Total Demand (psi) (gpm) 139.253 I 700.15 Required (psi) 107.698 Safety Margin (psi) 31.555 J t [7:', 2 r 2008 ?uK'3'Dt9 61-7 �i5%tra�ia Contractor Number KS0319 Content Name Adam Kantner Contact Tale Project Manager Contractor Name Western States Fire Protection Phone 425.881.0100 Extension Address 1 7102 180th Ave Ne, Suite A-105 FAX 485.736.9032 Address 2 E-mail City Redmond State WA Zip Code 98052 Web -Site (y ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:02PM Page 1 Job Number: KS0319 Report Description. Ordinary Group II Device Actual Flow (gpm) Minimum Flow lgpm) K -Factor (K) Pressure (psi) Sprinkler 110 31.57 26.00 5.6 31.781 Sprinkler 109 31.10 26.00 5.6 30.852 Sprinkler 107 29.51 26.00 5.6 27.767 Sprinkler 108 29.64 26.00 5.6 28.005 Sprinkler 117 34.26 26.00 5.6 37.437 Sprinkler 106 27.68 26.00 5.6 24.438 Sprinkler 116 34.17 26.00 5.6 37.235 Sprinkler 105 27.44 26.00 5.6 24.013 Sprinkler 113 33.25 26.00 5.6 35.246 Sprinkler 104 26.49 26.00 5.6 22.384 Sprinkler 112 33.13 26.00 5.6 34.997 v Sprinkler 101 26.00 26.00 5.6 21.556 Sprinkler 102 26.05 26.00 5.6 21.638 Sprinkler 114 33.67 26.00 5.6 36.151 Sprinkler 103 26.18 26.00 5.6 21.862 te,', Most Demanding Sprinkler Data © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:03PM Page 2 Job Number: KS0319 Report Description: Ordinary Group II Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 111 12-10 P0(10-0) 66.378 115 12-10 P0(10-0) 66.001 209 12-10 P0(5-0) 40.642 217 12-10 P0(5-0) 40.004 223 12-10 P0(5-0) 35.997 227 12-10 P0(5-0) 35.677 272 12-10 52.616 273 12-10 34.786 235 12-10 P0(5-0) 48.241 236 12-10 P0(5-0) 31.304 238 12-10 P0(5-0) 48.042 243 12-10 P0(5-0) 31.110 246 12-10 P0(5-0) 45419 247 12-10 P0(5-0) 28.255 250 12-10 P0(5-0) 45.157 255 12-10 P0(5-0) 27.905 287 12-10 P0(5-0) 27.389 256 12-10 E(2-0) 44.922 261 12-10 E(2-0) 27.368 349 -0-1 T(50-0) 100.458 359 -0-1 P0(26-4) 100.366 389 3-8 BFP(-4.500) 103.384 110 8-4'A Spr(-31.781) 31.781 31.57 109 11-0 Spr(-30.852) 30.852 31.10 107 11-0 Spr(-27.767) 27.767 29.51 108 8-4'1A Spr(-28.005) 28.005 29.64 117 11-0 Spr(-37.437) 37.437 34.26 106 11-0 Spr(-24.438) 24.438 27.68 116 11-0 Spr(-37.235) 37.235 34.17 105 11-0 Spr(-24.013) 24.013 27.44 113 8-4% Spr(-35.246) 35.246 33.25 104 8-4% Spr(-22.384) 22.384 26.49 112 11-0 Spr(-34.997) 34.997 33.13 101 11-0 Spr(-21.556) 21.556 26.00 102 10-0 Spr(-21.638) 21.638 26.05 114 10-0% Spr(-36.151) 36.151 33.67 103 10-0 Spr(-21.862) 21.862 26.18 1 -6-0 S 107.698 450.15 (61� © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:04PM Page 3 Job Number: KS0319 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Eq. Length Total Length Pressure Summary Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Route 1 DR 1.049 Q=26.00 9.65 C=120 0.211434 26-8% Pf 7.128 101 11-0 q=26.00 K=5.6 21.556 Spr(-21.556) 7-0 Pe -0.779 255 12-10 27.905 E(2-0), P0(5-0) 33-8% Pv BL 1.610 Q=78.23 12.33 C=120 0.201458 1-9 Pf 0.350 255 12-10 27.905 Pe 247 12-10 28.255 1-9 Pv BL 1.610 0=104.73 16.50 C=120 0.345562 8-3 Pf 2.854 247 12-10 28.255 Pe 243 12-10 31.110 8-3 Pv BL 1.610 0=132.17 20.83 C=120 0.531499 0-4% Pf 0.194 243 12-10 31.110 Pe 236 12-10 31.304 0-4% Pv BL 1.610 Q=159.85 25.19 C=120 0.755603 4-7% Pf 3.482 236 12-10 31.304 Pe 273 12-10 34.786 4-7% Pv BL 2.067 0=159.85 15.28 C=120 0.223783 4-0 Pf 0.891 273 12-10 34.786 Pe 227 12-10 35.677 4-0 Pv BL 2.067 0=189.49 18.12 C=120 0.306529 1-0% Pf 0.321 227 12-10 35.677 Pe 223 12-10 35.997 1-0% Pv BL 2.067 0=219.00 20.94 C=120 0.400641 10-0 Pf 4.006 223 12-10 35.997 Pe 217 12-10 40.004 10-0 Pv BL 2.067 0=250.10 23.91 C=120 0.512225 1-3 Pf 0.638 217 12-10 40.004 Pe 209 12-10 40.642 1-3 Pv BL 2.067 0=281.67 26.93 C=120 0.638219 29-9 Pf 25.359 209 12-10 40.642 10-0 Pe 115 12-10 66.001 Z, P0(10-0) 39-9 Pv CM 4.260 0=281.67 6.34 C=120 0.018856 20-0 Pf 0.377 115 12-10 66.001 Pe -0.000 111 12-10 66.378 20-0 Pv CM 4.260 0=450.15 10.13 C=120 0.044889 440-11 Pf 28.395 111 12-10 66.378 191-7% Pe 5.593 359 -0-1 100.366 12fE(8-11 %2), 2fEE(4-5%), 632-7 Pv 2Ee2(5-3), fE(6-9%), CV(28-11 %), GV(2-7%), P0(26-4) FM 8.329 0=450.15 2.65 C=120 0.001714 21-10 Pf 0.092 359 -0-1 100.366 32-0 Pe -0.000 349 -0-1 100.458 2fE(16-0) 53-10 Pv MS 10.020 0=450.15 1.83 • C=120 0.000697 20-2 Pf 4.561 349 -0-1 100.458 --, 67-0 Pe -1.635 389 3-8 103.384 3LtE(16-0), BV(19-0), BFP(-4.500) 87-2 Pv UG 10.400 0=450.15 1.70 C=140 0.000437 -- 113-1 Pf 0.114 389 3-8 103.384 146-8 Pe 4.200 1 -6-0- 107.698 3LtE(25-6), E(35-1), 2EE(17-6%), S 259-9% Pv = Route 2 DR 1.049 0=26.05 9.67 C=120 0.212180 25-10 Pf 6.963 102 10-0 q=26.05 K=5.6 21.638 Spr(-21.638) 7-0 Pe -1.212 287 12-10 27.389 E(2-0), P0(5-0) 32-10 Pv BL 1.610 0=52.23 8.23 C=120 0.095415 5-5 Pf 0.516 287 12-10 27.389 Pe 255 12-10 27.905 5-5 Pv elo Route 3 DR 1.049 0=26.18 9.72 C=120 0.214210 27-4% Pf 6.718 103 10-0 q=26.18 K=5.6 21.862 Spr(-21.862) 4-0 Pe -1.212 261 12-10 27.368 2E(2-0) 31-4'% Pv BL 1.610 0=26.18 4.13 C=120 0.026593 0-9% Pf 0.021 261 12-10 27.368 Pe 287 12-10 27.389 0-9'% Pv ia. Route 4 DR 1.049 0=26.49 9.84 C=120 0.218935 28-8 Pf 7.806 104 8-4% q=26.49 K=5.6 22.384 Spr(-22.384) 7-0 Pe -1.935 247 12-10 28.255 E(2-0), P0(5-0) 35-8 Pv car Route 5 DR 1.049 0=27.44 10.19 C=120 0.233631 26-8% Pf 7.876 105 11-0 q=27.44 K=5.6 24.013 Spr(-24.013) 7-0 Pe -0.779 243 12-10 31.110 E(2-0), P0(5-0) 33-8% Pv iiip Route 6 LM ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:05PM Page 4 it Job Number: KS0319 Report Description: Ordinary Group II Diameter Flow Velocity HWC Friction Loss Pipe Type Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream DR Length Eq. Length Total Length Pressure Summary 1.049 Q=27.68 10.28 0=120 0.237457 106 236 12-10 31.304 E(2-0), P0(5-0) 11-0 q=27.68 K=5.6 24.438 Spr(-24.438) 25-2% 7-0 32-2'% Pf 7.644 Pe -0.779 Pv QD Route 7 DR 1.049 Q=29.51 10.95 C=120 0.267234 107 11-0 q=29.51 K=5.6 27.767 Spr(-27.767) 223 12-10 35.997 E(2-0), P0(5-0) 26-8% 7-0 33-8% Pf 9.009 Pe -0.779 Pv = Route 8 DR 1.049 Q=29.64 11.00 0=120 0.269354 108 227 8-4% q=29.64 K=5.6 28.005 Spr(-28.005) 12-10 35.677 E(2-0), P0(5-0) 28-8 7-0 35-8 Pf 9.606 Pe -1.935 Pv • Route 9 DR 1.049 Q=31.10 11.55 C=120 0.294583 109 11-0 q=31.10 K=5.6 30.852 Spr(-30.852) 217 12-10 40.004 E(2-0), P0(5-0) 26-8% 7-0 33-8% Pf 9.931 Pe -0.779 Pv imp Route 10 DR 1.049 0=31.57 11.72 C=120 0.302783 110 8-4% q=31.57 K=5.6 31.781 Spr(-31.781) 209 12-10 40.642 E(2-0), P0(5-0) 28-8 7-0 35-8 Pf 10.795 Pe -1.935 Pv • Route 11 DR 1.049 Q=33.13 12.30 C=120 0.331015 112 11-0 q=33.13 K=5.6 34.997 Spr(-34.997) 250 12-10 45.157 E(2-0), P0(5-0) 26-0'% 7-0 33-0'% Pf 10.939 Pe -0.779 Pv BL 1.610 0=66.80 10.53 C=120 0.150395 250 12-10 45.157 246 12-10 45.419 1-9 1-9 Pf 0.262 Pe Pv BL 1.610 0=100.05 15.77 C=120 0.317522 246 12-10 45.419 238 12-10 48.042 8-3 8-3 Pf 2.623 Pe Pv BL 1.610 0=134.22 21.15 C=120 0.546831 238 12-10 48.042 235 12-10 48.241 0-4% 0-4% Pf 0.199 Pe Pv BL 1.610 Q=168.48 26.55 C=120 0.832779 235 12-10 48.241 272 12-10 52.616 5-3 5-3 Pf 4.374 Pe Pv BL 2.067 Q=168.48 16.11 0=120 0.246640 272 12-10 52.616 111 12-10 66.378 P0(10-0) 45-9% 10-0 55-9% Pf 13.763 Pe Pv os Route 12 DR 1.049 Q=33.25 12.34 C=120 0.333196 113 8-4% q=33.25 K=5.6 35.246 Spr(-35.246) 246 12-10 45.419 E(2-0), P0(5-0) 29-4 7-0 36-4 Pf 12.108 Pe -1.935 Pv ▪ Route 13 DR 1.049 0=33.67 12.50 0=120 0.341104 114 10-0% q=33.67 K=5.6 36.151 Spr(-36.151) 256 12-10 44.922 2E(2-0) 25-3 4-0 29-3 Pf 9.980 Pe -1.209 Pv BL 1.610 0=33.67 5.31 C=120 0.042347 256 12-10 44.922 250 12-10 45.157 5-6% 5-6% Pf 0.235 Pe Pv = Route 14 DR 1.049 Q=34.17 12.69 0=120 0.350556 116 11-0 q=34.17 K=5.6 37.235 Spr(-37.235) 238 12-10 48.042 E(2-0), P0(5-0) 26-0% 7-0 33-0% Pf 11.585 Pe -0.779 Pv Route 15 DR 1.049 Q=34.26 12.72 C=120 0.352315 117 11-0 q=34.26 K=5.6 37.437 235 12-10 48.241 Spr(-37.437) E(2-0), P0(5-0) 25-10% 7-0 32-10% Pf 11.583 Pe -0.779 Pv Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter 4.87 = Factor Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 (, © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:05PM Page 5 Job Number: KS0319 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Length Eq. Length Total Length Pressure Summary .................... AO Arm -Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV AngV b BaIV BFP BV C cplg Cr CV DelV DPV E EE Eel Ee2 FDC fE fEE flg FN rr g GIoV GV Hose HV Hyd LtE mecT Noz P1 P2 PIV PO PrV PRV red S sCV Spr St T Tr U WirF WMV z Alarm Valve Angle Valve Bushing Ball Valve Backflow Preventer Butterfly Valve Cross Flow Turn 90° Coupling Cross Run Check Valve Deluge Valve Dry Pipe Valve 90° Elbow 45° Elbow 11%° Elbow 22W Elbow Flow Device Fire Department Connection 90° FireLock(TM) Elbow 45° FireLock(TM) Elbow Flange Floating Node FireLock(TM) Tee Gauge Globe Valve Gate Valve Hose Hose Valve Hydrant Long Turn Elbow Mechanical Tee Nozzle Pump In Pump Out Post Indicating Valve Pipe Outlet Pressure Relief Valve Pressure Reducing Valve Reducer/Adapter Supply Swing Check Valve Sprinkler Strainer Tee Flow Turn 90° Tee Run Union Wirsbo Water Meter Valve Cap © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:05PM Page 6 Job Number: KS0319 Report Description: Ordinary Group II Supply at Node 1 Pressure, psi > cn o f'n 8> cn `S 8 8 c`'n ti II Illi t Il t i 1 I i t l II l l 1 i ti l t l It III 1111111111 I II I t It t111111 III t I t Il IIII I I III II Li till i I t I t i I 1 I IIIII Static Pressure 140.000 .700.15 ,50.15 with hose @ 107.698 streams System demand curve 10900.00 @ 20.000, ff lnllutl flulllll 11/11/111 11111 1 1 1 1 111111111 111111111 1 1 1 1 1 1 1 1 1 1 I I 11II! 0ciliu V 9900 11000 710022M 3300 4400 5500 6600 7700 8800 Water flow, gpm Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.253 @ 700.15 System Demand 450.15 @ 107.698 System Demend (Including Hose Allowence) 700.15 @ 107.698 (Aly ©M.E.P.CAD, Inc. 441 AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:06PM Page 7 Job Number: KS0319 Report Description: Ordinary Group II [M, © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/21/2008 7:17:07PM Page 8 K 13-Y VICTQIA'S s7Fol:z FIRE ALARM SYSTEM DDITI N TUKWILA, WASHINGTON S EET \UMBE SHEET TITLE EA -01 SYSTE V I\ FORIVATIO\ FA -02 TYPICAL WHI\G A\3 VOU \TI\ G DETAILS FA -03 SYSTE V CALCULATIO\S A\D SI\GLE LIKE DIAGRAM FA -0 MAI\ FLOO FR ALAS V SYSTEM. PLA\ FA -05 -EMOTE STORAGE FLOO FRE ALARM SYSTEM PLA\ • SHEET INDEX 0 Without Comments As Noted in Red ID Per The Attached Letter These plans have been reviewed by The Tukwila Fire PrEvention Bureau for conformance with current City srzr.dards. Acceptance is subject to errors and o„m:sslons which do not authorize violations of adopted standards an.; ordinances. The responsibility for the - ns rjpctnf roc.tc fntaily with t4^o rias annr, r�-:U LI l W, uGl:=JV1 w t • $ GVIJivn , w _, •c_,.. .,, Awl, 1 .) atter this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance 1s subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: �Z-13 By: 51( WRE No. nd exact a cI-e;! s or shut- down or restorattn approval. 9 v L A\D CO\i.,IT FILL C AT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. - DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE EN`/IRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMA SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 4 4 5 9 12 NORDSTROM 3 LEVELS SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL bb" A.F.F. TO TOP DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING HVAC DUCT WORKS DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1G BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2" EXTN CEILING TENANT J -BOX El_ (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END-OF-LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND macys PINK BY VICTORIA'S SECRET 1220 /SPACE #1125 w PMC CES PES:A.1fl$ P0,) ft Irey Ir) cC J (n 0\ 0' •9 C'•,1 RELEASE/REVISIONS LL DESCRIPTION 0 z a- 0 w H- 0 ,1; a<hKii W cc 0 (1) O F- 0 ca z N O w"I- QC) CD z cf)O W<Z WZ W `t WCC LL �F- G RI .-CALE: NOT TO SCALT DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 /06/ 17 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rig erved JAN 24 Me TUKWILA FIRE JOB NUMBER: 26641 --1 SHEET THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ — DEDICATED EMERGENCY FROM EXISTING MAIN FACP C CABLE C' CABLE O ai aJia GRD N L 0 0 O PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - B O 0 0 ,n (—) (+) (—) (+) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE NAC S4 NAC S3 NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSION CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) O (—) STROBE SPEAKER (+) (—) FROM PREVIOUS ADDRESSABLE 2 DEVICE HFP-11 TBI @CXDOT NO COM NC TO FAN SHUTDOWN EOLR 470 0 °O TO NEXT e ADDRESSABLE DEVICE 0 00 HTRI-R NO COM 0 NC 0 °/L TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) (—) STROBE (+) () STROBE SPEAKER SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ASHINGTON 98134 FAX (206) 628-4990 IS1 AVE_. SO., J JJ RELEASE/REVISIONS REV. BY: SWITCH + — INPUT LED TSM -1 0 °O TO NEXT e ADDRESSABLE DEVICE 0 00 HTRI-R NO COM 0 NC 0 °/L TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) (—) STROBE (+) () STROBE SPEAKER SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ASHINGTON 98134 FAX (206) 628-4990 IS1 AVE_. SO., J JJ RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE N- ciD0 2 <„-.<_1 -' c4 I J w 0 I 0 — W N 7 CCT 2 ; co z co W 0 I-1-1 «� Fa” 70 oct© O �Q 0 cf)Cr� . � UQW� � Et(j)I- o % N CI , .6§-11 CV SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 /06/17 BACKROUND PLAN PROVIDED BY: \OB NUMBER:2664 i -12 I. SHEET FA -02 A B C D E F G H I J K FIRE ALARM BOOSTER Project: PINK BY VICTORIA'S Panel: NEW BPS PAD -3 BOOSTER Date: November 8, 2017 Module/Device POWER SECRET POWER Qty SUPPLY SUPPLY Standby (mA) BATTERY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 3611 Total(A)= 15 Total(B)= 3751 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 3751 Total current ratings converted to amperes (line D x .001) 0.015 3.751 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.3124583 Add lines G and I Total Standby and Alarm AH 0.6724583 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.80694996 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: PINK BY VICTORIA'S SECRET Panel: NEW BPS PAD -3 BOOSTER POWER SUPPLY Date: November 8, 2017 Wire Resistance 2.58 CURRENT TOTAL= 3611.00 4 SET -MC -CW @l5cd SET -MC -CW @30cd SET -MC -CW ©75cd SET -MC -CW @95cd 7 ZR -MC -CW @l5cd ZR -MC -CW @3Ocd DEVICES 11 69 111 200 264 64. 111 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage SET -MC -CW @15cd 1 SET -MC -CW @30cd 5 SET -MC -CW @75cd SET -MC -CW @95cd 2 ZR -MC -CW @15cd ZR -MC -CW @ 30cd DEVICES 10 276 0 0 0 448 0 724 14 69 138: 111 111 200- 1000 264 0 69' 138 111 0 TOTAL mA=: 1387 14 Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 280 326 22.95 ( WL * 2 )* (R/ft) (Total Oct Load) (E= I * R) 24-E) 724 1.44 0.72 1.05 22.95 21.67 ( WL * 2 )* (R/ft) (Total Cct Load) (E= I * R) 24-E) 1387 1.68 1.39 2.33 21.67 CALCULATIONS PI ' VICTORIA ACP:ADD-ONS Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 4 0.0022 0.0022 0.0023 0.009 FDBZ492-HR 4 0.0635 0.0635 0.064 0.256 HTRI MODULE 5 0.009600 0.0096 0.021 0.105 0.0731 Amps 0.361 Amps Notification Appliance Circuit Detail - VOICE PROJECT: PINK BY VICTORIA'S SECRET Panel: EXISTING SPEAKER CIRCUIT Date: November 8, 2017 Wire Resistance 2.58 CURRENT TOTAL= 254.88 72 SET -MC @1!4 -WATT 3.54 SET -MC @1/2 -WATT 7.08 SET @1/4 WATT 14.14 SET @1/2 -WATT 28.29 DEVICES 72 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 254.88 0 0 0 254.88 14 1055 22.61 254.88 ( WL * 2 )* (R/ft) (Total Cct Load) (E= I * R) 24-E) 5.44 0.25 1.39 22.61 D,I HT -R 21 TSM 82-1 S2-2 75Cd 75Cd REMOTE STORAGE LEVEL 120VAC DEDICATED ( BY OTHERS) IBPSI 2S b Sv V S,V S,v S2-3 S2-4 30Cd 75Cd S V V S,V S,v S,v S,v S2-5 S2-6 S2-7 S2-8 S2-9 75Cd 75Cd 15Cd 15Cd 15Cd S,V S2-10 15Cd EOL S2 D EXISTING TENANT J -BOX S1-1 S1-2 15Cd 15Cd HT -R S1-3 S1-4 S1-5 S1-6 S1-7 15Cd 15Cd 15Cd 15Cd 15Cd S1-8 15Cd S1-9 15Cd S1-10 15Cd S1-11 15Cd EOL S1 MAIN FLOOR LEVEL SINGLE LINE DIAGRAM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 0" 17433 IST AVE. SO., SEATTLE, WASHINGTON RELEASE/REVISI CO LU Cr 0 0 DESCRIPTION SHOP DRAWINGS W I- 0 0 z I - w CSC 0 w CI) C/) Ci 0 F- > - CO z 1. N Z co p wT cn u)O �O Lu < z _ W< z� U� LuCC r OH 0 N cC c3 l LU LU 0 C-0 06 z 0 0 F- 00 CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1/06/1 7 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 26641-1 I SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved " / TO EXISTING TENANT JUNCTION BOX TO EXISTING TENANT _ — JUNCTION BOX E--_ -: TO EXISTING TENANT JUNCTION BOX S,V D I HT -R1 S1-1 15Cd S1-3 15Cd SO S1-4 15Cd/ D HT -R TSM /N iI • S S1-2 15Cd s V S 3 CCd J 0 r, IHT—R-' ITSMI S1-8 15Cd S1-5 15Cd S1-9 15Cd I tJ S2-4 75Cd siv FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. ( s.v S2-5 75Cd S2-6 S 75Cd LI S1-7 15Cd o—S V CEO S2 S2-10 15Cd S1-6 15Cd_ c S S1 -11i; 1594 S1-10 15Cd EOL S1 S2-8 15Cd S2-9 15Cd • MAIN FLOOR FIRE ALARM SYSTEM PLAN 141 N) U` 0, 00 N 174.:7 ISi AVE. SO., SEATTLE, WASHINGTON RELEASE/REVISIONS CO > w DESCRIPTION z Q 0 0 w F - Q 0 z <K<K,, CL W i T j wow- ci) Ft ci) 0 (no G O 03cc cr) < WQ Uz LU J Le.)LL rI ca CC © O N 0LL z �CALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 /06/ 17 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 266411 -1/ SHEET `` \ FA -04 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved J WEN ■ ■ ■ie■V■ ■A■ ■O■ ■ai■ ■!X■ ■ »■N ■!■ F■R■VENEW■V■V■ 0 LL N N I N LL N ct N N N 2 0 U. N N EVE EVES 2442F O'H 2442F F 10'H 2442F F 10'H 2442F F O'H 2442F F O'H z 1 J J D HT -R ITSMI REMOTE STORA GE DN TO EXISTING TENANT c JUNCTION BOX L S2s S 75C L co- S S2- S 75C RR 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M 10'H M# 2442M 10'H M410'H 2442M M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M 1 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M *1 Fl -i Rf 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M 1, `10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M((,� M# 2442M M# 2442M M# 2442M ]]��llL {III -It iiII (� 1 it 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M 10'H M# 2442M M# 2442M M# 2442M M# 2442M M# 2442M o-S,V ULU uu sv REMOTE STORAGE FLOOR FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. IST AVE. SO., SEAT1LE, V N) J Z O_ w CZ LU u) W J LU CZ CO w CD 0 DESCRIPTION SHOP DRAWINGS w I- 0 N c0 0 I— W L a T oz Wow U) I W33) � o �o Ci wdz_ O �L_ Ucz� > >— w F °T z o NCL COEL >CC w CC0 O Li_ w 0O D w CALE: 1 /4"=1 '0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 1 1 /06/17 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 26641 —12 r SHEET �y FA- 0 5 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved t, .:9 FIRE ACARINE SYSTE TUKWILA, WA.HINGTON SHEET INDEX SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALAaM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLAN Per The 11 :., `.. ;'•r +.'. _^Ii .. .t:' . ..,_ :,::..'!ie Fire ;I: :'' _;I ; c... :: t rl_17eflt city C'I rurs and ;, ,..c`t O: ;so: Ji:i i il. 'CJi�ii�'fj5 rf adopted r:. ii(`•i •Sih .ty for the h_ + :; % r;:;u atter a rF I;uant approval. Tu - .0 ..._ test and inspection by 61-2 Cy: SIC CUKWILA FIRE DEPARTMENT. Please call: 575-440Z and give this job and exact address for shun Down or restoration aoDroval: .1 NOTICE A completed, signed, Tukwila Fire Department Pre-test C;.rtificate must be presented in the Inspector prior to -:s nmencement of Acceptance Testing of any Fire Alarm aid Detection Systems. Failure of test will result Re -inspection Fee and I (ination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR. W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART„ ..... - . NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. _0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE ' 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE,. FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED.' IN` DIRECT. AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. - 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND .760 OF :NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES ,SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, 'WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL: BE MOUNTED AT 48' A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS' WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE. AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR. TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. . 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT ' CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH .A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND. RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 5 4 8 1 2 1 SYMBOL DESCRIPTION SYMBOLS ,LEGEND MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP I BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP ® INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD LINEAR BEAM I N SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT SMOKE p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING gL C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXT. FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM sc FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -HMC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. L FIRE ALARM STROBE C (CEILING MOUNT) ZR -MC -CW' SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX WI 1G RING 80" A.F.F. TO BOTTOM U.O.N. Q FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 11/2" EXT. TO BOTTOM FIRE ALARM BID STROBE WP (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD El MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A: N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A NSA BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A 1,0 oo 0` O 0' 0' O0. CV 0 0 cV >G Q U uJ F- - . , 2000 Tukwila Fire Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved` 0 z • SCALE: 1/8'1=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: ,OB NUMBER:54535 } SHEET FA-Ol , THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE. SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AIR DUCT 6-10 DUCT EQUIVALENT DIAMETERS DUCT DETECTOR LOCATION o TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC END OF LINE DEVICE (3.6K 1/4W) SUPERVISED SWITCH it 0 M GROUND_ 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 0 HTRI—R 4110 STATUS LED co 0 N.O. I` 0 CO 0 COM N.C. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL L EL KALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH- C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING-'\ TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE L} -AC POWER SOIJRCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING ;' TO NEXT ADDRESSABLE DEVICE` .p.0 STOP IF LAST DEVICE FROM XLS CONTROL PANEL ORT) PREVIOUS ADDRESSABLE DEVIC) RELAY CONTACTS (4.0A @ 125VAC) (4.0A B 30VDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 ' AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. i + 000 12345.6. HCP TB2I00 6 5 O 0 +b 4321 0 0 END OF . LINE Z I — DEVICE ..r 0 (3.6K 1/4W) — / SUPERVISED I SWITCH . GROUND ----- NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. �t- O HTRI—D STATUS LED co 0 0 NOT USED (0 0 0 -TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABEL KALE (FIRE SUPPRESSION SYSTEM INTERFACE) - 0 GND N AC II 0 0 PAD -3 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX ,'1+1- 1.2+ 2- 2 NC. C NQ •t +.- t.- + - +- raIMITIMIMI611a 24K I`'"II` 10110-IiM TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE r FRONT VIEW 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE _ DEVICE LOOP NOT USED REMOTE DEVICE LOOP FROM XLS CONTROL PANEL OR (-F), PREVIOUS ADDRESSABLE DEVICE (-)> 0 a a a TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL EARTH GROUND ->(+)TO NEXT DEVICE OR >(-) STOP IF LAST DEVICE FROM REMOTE POWER SUPPLY ('S' CABLE) END OF LINE DEVICE FROM FACP 3.6K 1/4W) . (VOICE CIRCUIT) S('V' CABLE) UPERVISED 1 SWITCH 2 NAC -4 2 NAC -3 NAC -2 ?NAC -1 SCALE NONE (-) STR❑BE) SPEAKER (-) (-) (--) (-) STROBE • '1 O-) ( ) STROBE SPEAKER SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 4S DEEP BOX W/ 1 -1/2 - EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE �TO NEXT . DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. HFP-11 SMOKE DETECTOR - . FROM PREVIOUS ADDRESSABLE DEVICE OR POKER SOURCE DATA IN (-) >- DATA IN (4-) > DEVICE IS USTED FOR AIR VOLOOTY APPLICATIONS OF 300-4000 HAIN WHEN USED IN CONJUNCTION ICH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW > ( ) DATA OUT 1 > (+) DATA OUT )r TO NEXT DEVICE HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID -- CEILING HARD LID _\ SPEAKER SUPPORT TLE - - BRIDGE c C/3 a cc z CO (T O I- CD (/) UJ F- W (I) cn W cn f'0 CD 0• ' 00` CD N X., CV CV '0' CD CV _I LU F- •. WITH 1-1/2' EXTENSION N —CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE JUNCTION BOX MOUNTED ON \ CEILING FLEX \ JUNCTION BOX 6OUNTED AGAINST '- CEILING SUPPORT 0 0 SMOKE DETECTOR --- SMOKE DETECTOR MOUNTING TO NEXT DEVICE ----CADDY BAR SUSPENDED ILLUMINATED CEILING co co cr cf) 12Z w 04,e- 0 0 DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI BACKROUND PLAN PROVIDED. BY: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved SHEET . ;-. • ;•';. ' • • 1 1 LI I „- I EOL 18.3 3VE A:2 " ALE V A 7 CIE.. . , . N. 7 0 .X , . : .. V N - , -N. 11 V N. 75 1;11 II r- : I .1 t P-12 . 1 i•\.1 ....:, • 2S,2V i rf- 'I' R' ; s 1:7=.: '4, rl L _ A 30 JI CORR:DO', ; .-;. '420 2S,. V 1z I 30 • :I”. ,./151.1 In 0 c:=>— 2S,2V c;>--2S,2V --„-_,7 __--_-1 -P-1, ., I 1.:V..ifF 501.11` Ft,.., -F 14.0,111illi 1.410:4' ill, SI,, 2S,2V. ME NS E 2S .., .? +11-1.Rli 4TIFITIEREIHRIPFEMTETITIPIRDIPTARTEDIRSERBI \ . 15_ V WON -1E NS 0-720 104- -I ITIATCJ-; • ::-.NORTH r [1 • A EIJA C E T T C.) r; m 1:3 SALES FLOCRi • '; t --- --- --,-;;72t-..i.7 r -,- . . . • 1117;ff47gq.- TUDIJ ittr; ---- –2S,2 ry F r -4-1H' 1--c- 11 -7:47-IL „FAiligiskLIVAIX93. , BAITTRENVARIPI A I ' „ 1 I I 1. R0017,4 42 SALES FLOCP 2S,2V ELICIt SC:FF•T-F H.TI.1 FACE Cf 12.1:0 0 L s' FIT DUG ItSO,rI A F.) V E 9'- PC q -T; - F "!J 1.11, PINK WESTFIELD SOUTHCENTER MAL SCALE 118':V I P -2c; • czwyer TAP. • ' • • • • • . , • , P 2 : - - - E c:damr, 11 I;; • 4' 47Tc 727-1 26 --CEILAT T3 NATO:: OF T.4.6D A' • AFACr fe. 1: -..;OM F: SALES FLOC)" a- El Irm ..- . 1)(1 • ..y.,- _ -,;,1-(&_.,-/x7L-i•FzTol..3.-:.ff-21-..-ffri:?, :i ---:i: LIE`ift.,247:11Triffileitt.H.1.1111115IA: _____ •'• C 4 FLAG NOTES: Copyright FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. j i•; ! i : • : • i I • I! . : 1! • ; • ' • . • .• . 2006 by Guardian Security Systems, Inc. All: Rights Reserved ND 0' CO 174.3 ST AVE. SO.; SEATTLE, WASHINGTON CI) RELEASE/REVISI LLJ DESCRIPTION 0 0 co w ct 6ALE: 1/8"=1' DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01/08 BACKROUND PLAN PROVIDED BY: ._10B NUMBER:54535 SHEET FA -03 NORDSTROM \ FE I NORTH BEN PARFUN4ERIE SUN M TiON Si PINK! WESTFIELD SOUTHCENTER MALL SCALE MN' S,2V 2S,2V 2S,2V a 11 110 75 75 30 C 30 15 15 30 S,2V. • El • a 15 S,2 V S,2 V 30 . 75 EOL -S1 • 18.33V S,2V • LLO LflUJ < c 2S,2 V -<=3 D 1 PUBLC CORR. Cr) Cf.1 Ui D 0 LID LID41. LID " a a 21 21 • 2I 0.,4. 21 RISER DIAGRAM LL! Cf Lii Cr. . : 5_5 CL I 1)] ;1,%\ • Ui ft.; :SD F--- •.- SYSTEM CALCULATIONS • ; - BATTERY SIZING CALCULATION ; I : Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: PINKS! Date: May 6, 2008 !Wire Resistance 1.62 CURRENT TOTAL= 1342 CIRCUIT:!S1 QTY Device Type i I i ; 1 f , 1 ' f Alarm Current i Alarm Total 1 Wire Size ! Wire Length i . Voltage at EOL i Circuit Total 1 1 ' . • • , . 1 SET -MC @15CD 641 641 4 SET -MC @30CD 981 3921 3 1SET-MC @75CD 1751 5251 1 SET -MC @110CD 2331 2331 iTOtal Wire Resistance ( R ) ( WL * 2 )* (R/ft) - iTotal Device Load, Amps (I) 1.62' 1.34! , , 1 I : •cTotal Cct Load) ! 1 i . Voltage Drop ( E ) 2.171 ' , I 0 :SET-HMC-C@115CD 3181 01 0 !SET-HMC-C@177CD 445! Oi 0 !SET -HMC @135CD 318; 01 0 SET -HMC @185CD 445 0 2 Z-MC@15CD;64! 1281 1 -(E= * R) lEOL Voltage ; . i I i ; • - --- --- -- • - i . _ (20.4 - E) •I .,.„ ..... ... i . t ! i I t t•i i t .. 0 23 A i i I 18.23' 0 IZ-MC@30CD 931 18'. 01 ISET-MC-CW@110CD Oi DEV10ES=1 1 TOTAL mA=, 1342! 12 ; 500 18.225961 1342 Notification Appliance Circuit Detail PROJECT:1WESTFIELD SOUTHCENTER MALL Panel: PINKS !Wire Resistance ,2.58-, Date: May 6, 2008 CURRENTTOTAL= 16.2 CIRCUIT: i SPEAKER CIRCUIT ' - QTY Device Type 'Alarm Current Wire Alarm Total I Size 1 VVire Length Voltage at EOL Circuit Total . 1.8i 1Total Wire Resistance ( R ) 1 258 0! o -2 ) * (R/ft) - - 0 . . 0 I Total Device Load, Amps (I) , 0! •0! 1 •,•i .FVolt,age Drop ( E ) 0 - 0 • 0 ; 01 - 0 - i - . ; ; .; t i . i i - I . , ; 1 1 lE; 0; L(EV-oll Voltage - , , , o 01 01 I ! - i i 1 - (20.4 - E) , i 1 t 20.361 .._ (Total Cct Load) 0.02! I • . 1, 0.041 0 01 0 • 0 0! ; i i .„ 1 , 0 • _ I 0' - - 01 - , -_ 1 •, ; m = I - , 2 . DEVICES=19 TOTAL A -16.21 - 14 .. -1 500 _ ..--1 " 20.358204 , i , -,- 16.2 • VOLTAGE DROP CALCULATION • ; ;• ; • , • ; • i;•1' '11v • . : • 11!' • • • •, } RELEASE/REVISIONS LLJ cr DESCRIPTION Lii FLii- 0 z CO CO _J 2 Z W 0 CC W z z t w o <es cc H F- D 0 LL1 F - w w z cr) z 0 Lu cf) DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01/08 . BACKROUND PLAN PROVIDED BY: NUMBER: 54535 • Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved: . , PINK! PINK! .. , FACP ADD ONS ,.. ,• SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations • , , „, . Current Load: Standby: Alarm: Current Load: Standby: Alarm: S Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 • 0.0022 0.0022 0.0023 • 1 „ 1 , 1, AD2-P ' , . 4 0.0635 0.0635 0.064 0.256 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R: HTRI-D ICP -B6 ' 5 0.009600 0.0096 0.021 0.105 SET -MC @15CD SET -MC @30CD SET -MC @75CD SET -MC @110CD 1 0.064 0.064 . 0.001600 0.0035 4 0.098 0.392 , '1 0.005 3 0.175 0.525 1 0.233 0.233 SET-HMC-C@115CD SET-HMC-C@135CD SET-HMC-C@185CD ZR -MC @15CD _ ZR4./IC @30CD HCP . 0.318 0.318 0.0731 Amps 0.361 Amps 0.445 2 0.064 0.128 Standby! Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours , 0.098 1 , , 0.0015 Alarm CUrrent Load: 0.361 Amps For 5 Minutes= 0.030 Amp -hours 0.03 Amps 1.372 Amps . , . , I , 1 Si! , :;• . , 1 . 25% Derating= 2.231 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours ,, ,; • , Alarm Current Load: , 1.372 Amps For 5 Minutes= 0.115 Amp -hours. , Total System Current Load: 2.231 Amp -hours 25% Derating= 1.044 Amp -hours •i ! .• Battery Pair to be Used: 12VDC Amp -hours 7AH . ; • , • • : • i ; ';. - Total System Current Load: 1.044 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH , • ; - BATTERY SIZING CALCULATION ; I : Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: PINKS! Date: May 6, 2008 !Wire Resistance 1.62 CURRENT TOTAL= 1342 CIRCUIT:!S1 QTY Device Type i I i ; 1 f , 1 ' f Alarm Current i Alarm Total 1 Wire Size ! Wire Length i . Voltage at EOL i Circuit Total 1 1 ' . • • , . 1 SET -MC @15CD 641 641 4 SET -MC @30CD 981 3921 3 1SET-MC @75CD 1751 5251 1 SET -MC @110CD 2331 2331 iTOtal Wire Resistance ( R ) ( WL * 2 )* (R/ft) - iTotal Device Load, Amps (I) 1.62' 1.34! , , 1 I : •cTotal Cct Load) ! 1 i . Voltage Drop ( E ) 2.171 ' , I 0 :SET-HMC-C@115CD 3181 01 0 !SET-HMC-C@177CD 445! Oi 0 !SET -HMC @135CD 318; 01 0 SET -HMC @185CD 445 0 2 Z-MC@15CD;64! 1281 1 -(E= * R) lEOL Voltage ; . i I i ; • - --- --- -- • - i . _ (20.4 - E) •I .,.„ ..... ... i . t ! i I t t•i i t .. 0 23 A i i I 18.23' 0 IZ-MC@30CD 931 18'. 01 ISET-MC-CW@110CD Oi DEV10ES=1 1 TOTAL mA=, 1342! 12 ; 500 18.225961 1342 Notification Appliance Circuit Detail PROJECT:1WESTFIELD SOUTHCENTER MALL Panel: PINKS !Wire Resistance ,2.58-, Date: May 6, 2008 CURRENTTOTAL= 16.2 CIRCUIT: i SPEAKER CIRCUIT ' - QTY Device Type 'Alarm Current Wire Alarm Total I Size 1 VVire Length Voltage at EOL Circuit Total . 1.8i 1Total Wire Resistance ( R ) 1 258 0! o -2 ) * (R/ft) - - 0 . . 0 I Total Device Load, Amps (I) , 0! •0! 1 •,•i .FVolt,age Drop ( E ) 0 - 0 • 0 ; 01 - 0 - i - . ; ; .; t i . i i - I . , ; 1 1 lE; 0; L(EV-oll Voltage - , , , o 01 01 I ! - i i 1 - (20.4 - E) , i 1 t 20.361 .._ (Total Cct Load) 0.02! I • . 1, 0.041 0 01 0 • 0 0! ; i i .„ 1 , 0 • _ I 0' - - 01 - , -_ 1 •, ; m = I - , 2 . DEVICES=19 TOTAL A -16.21 - 14 .. -1 500 _ ..--1 " 20.358204 , i , -,- 16.2 • VOLTAGE DROP CALCULATION • ; ;• ; • , • ; • i;•1' '11v • . : • 11!' • • • •, } RELEASE/REVISIONS LLJ cr DESCRIPTION Lii FLii- 0 z CO CO _J 2 Z W 0 CC W z z t w o <es cc H F- D 0 LL1 F - w w z cr) z 0 Lu cf) DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/01/08 . BACKROUND PLAN PROVIDED BY: NUMBER: 54535 • Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved: . , C7 Without Comments L7. As Noted in Red Per The Attached Letter These pians have been reviewed by The Tukwila Fire Bureau for conformance with current City -;dards: Acceptance is subject to errors and -, :sions which do not authorize violations of adopted ,ards and ordinances, The responsibility for the i uaCy: of design rests totally with the designer. tlotis, deletions or revisions to these drawings after •-' e will void this acceptance and will require a i;:=?or�liLtai of revised drawings for subsequent approval. a1 acceptance is subject to Heid test and Inspection by f ,r l'Clkwila Fire Prevention Bureau. s UKWILA FIRE DEPAR E TIr P:eaSP r1206-575-4407 and give this Fire Permit No. :trod • ac't address for shut- down _ down or restoration appt:oval. 111111;::,:,:�:=:=: ,.r,1111;14% Corrugated stainless steel hose with stainless steel brat aveilab€e in 2', 3',4',5' & 6' legnths . • 144 • • / Multi -Port Bracket - Adjustable Hub TOP BEAN/ C—CLAHP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL. RING F.lexhead omCrie.rciai Ceiijrig Unit • T -Bar belling installation - Model #2024,2036,2048,2060,2072 STEEL JOIST/TRUSS HANGER DETAIL DO NOT ROUTE ANY PIPING OVER ELECTRICAL EQUIPMENT ELECTRICAL CLOSET PINK 2 iz'v PINK 3 TRANS #4 TRANS #5 ADJACENT TENANT -. N.I.C. ter p . PIRB PROM@ • SP R$NKt.@R >sVBTeNI>r 8 el - John J. Abel a 9 '80.0691 e c . 't " a C Pre - , Ino. • BREAK AREA FIRE SPRINKLER HEAD PLAN BOUT/GI TER IAA. 1100 SOMME/MA MALL 10010.1. WA (MO VICINITY MAP Design per NFPA 13 - Ordinary Hazard Group 2 (Retail) ATI materials to tobe bewithin new, U.L. listed andof NF.MFPA, approved All heads to be at least 6' apart with no obstructions Instaation full compliance International requirements, and the local A HJ Fire Code, manufacturer o 59 — Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 - White CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425)481=7669 moue 16.2111100111 20001 NM IUD OWT0MCE 150 KEY PLAN Pink Victoria's Secret L-c-53TSouthcenter Mal Space 1125 Tukwila, WA 98188 DRAWN: • SCALE: VICINITY MAP (Suite# 646) SCALE: NT General Notes 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system pipirzig and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. FILE COPY WEST RISER DETAIL HYDRAULIC REFERENCE O TI. NOT TO SCALE MATCH MALL EXISTING 4" MAIN ZONE T-1 12-11% 2-11 -5 9-6 9-6 7-11 8•-8• 1 rk4' P-1 I 447 3 itI pry i.I r-6- ir Pee ir; ��/� ' C�O�� t 1 3.412ic - j 0-4%.. iI \ Cki ft: 0O ° Ir �0,NI +'1 ii el l4 iOtt" 240 c ® WC -22 ct h '40NSAL=-S 17.0 - AC --2 9 9 1-3 1 6•-8- P-26 r. SALES FLOOR Nri 11-0' P•28 -1 0 00 14 6=1 11=1`) M111 3213 » PINK Remote Area: Retail # 646 CALCULATION DESIGN CRITERIA: STANDARD NFPA # 13-2007 OCCUPANCY mass ORD HAZARD II MAX COVERAGE per HEAD 130 Ft= DENSITY .20 GPM / FN for 925.62 Ft' SPRINKLER Reliable Model G4A WATER FLOW INFORMATION*: STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER. SYSTEM REQUIRES: 450.15 GPM © 103.4 PSI ' At time of Design 11`-0" CLG.=38.5% AREA REDUCTION PP CT C Weld stamps must be inspected before pipe is hung. o not paint piping viler hydrostatic test approval. • nDam9 uoquene.td n 1 I!M)IV1J ILL i(q uoI}cadsui cue isal p; I.=, of loafrins sl acueld000e ieurd ]enoJdde}uan�c ;';:s .; ° ,,;;� pc:l ,, '110 l tlitgnsaa e aa;nb9..1 `. 1 , p t#3 `''� `Suo 1 ppv 'lit •._. - - �', � •: 4oenhepe Gill 'C; PI s; ietxle;s pG-4dopr3,;> L ,{ ;;i 31.IopS1wo •SpJ13pLI }s A;IO'i -.•• :_ ;1. Ii; -fil+s UOl;UatOJCJ "'.1I :I:' ! 1 '_ic: G`, :a'cq sueld GSSU ice:; ▪ 1 P0'43 -i1 cU_( gad p`4uN sV S,UGWWO j }i3Oq M D TUKWILA FIRE DEPARTivitill. Please call: 575-440Z :nd give thls job No. O3-S-IJD- and exact address for shute G.)‘ -tin or restoration approv l N 9 I .I • n itt CI 4 era rag NAT: T to I 10,1' P-28 • uta 11•-0- P-28 I 11 41'4 1-- 6•-4' P-25 rC 02 I 1t-o.—I' I P•26 Ii z.c 0 CO 3',4� i37h/s'>9 0 �`V \ SALES FLOOR ,` 4.,�N �� n___ o 90 1p-(/2 I!. 1 i., ,,I CO +°• ��' 1 1+�� -0/2 -8 ~L Q1M1 0Y�r� IJ 1 h 4t) I �l� eho 13 EXISTING 4" MAIN ZONE T-1 :::TYPICAL FLEXABLE SPRINKLER CONNECTIOW FLEXHEAD MOUNTING BRACKET PIPE NIPPLE " SPRiNKLER BRANCHLINE Corvi\i6fli\i6 HOSE IN STANDARD LENGTHS SUSPENDED T -BAR GRID CEILING TILE SPRINKLER HEAD NOT TO SCALE KWIK BOLT 1/4' EMBED LENGTH) FIG. 10QO "FAST CLAMP" SWAY BRAC E ATTACHMENT LATERAL UNE RESTRAINTS NON-THREADEO BRACE PIPE F10. 4A PIPE CLAMP FOR SWAY BRACE NC•THREAD SWIVEL SWAY BRAC E ATTACHMENT 3/8* KWIK BOLT (2 lg. EMBED anarre n. LATERAL BRANCHLINE RESTRAINT TEA NON -THREADED BRACE PIPE BRACE PIPE LATERAL BRANCEILINE RESTRAINT NOT TO SCALE SALES FLOOR 0 4t l P-28 CO 11to- !1 P -26_ j1 5-41A W2 Ordinary Group11.0.20Qpni/ft2 for 922.00ft2 FIRE SPRINKLER SYSTEM Hanger No. 07C HILTI Kwik Bolt III Cut Rod Lgth Rounded to Nearest Inch Rod Coupling All Thread Rod s' Swivel Ring Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'X Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE • ARCHITECT: PINNACLE CONSTRUCTION CONTRACTOR: SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE DESCRIPTION DATE SYM. SIN QTY. SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE R3615 10 5.6 Pendent Chrome 155°F F1FR Semi -Recessed APPROVAL: CITY OF TUKWILA HYDRAULIC REFERENCE POINT R5415 46 5.6 Pendent White 155°F Reliable G4A Concealed CONT. NO.: KS0319 Total = 56 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK. ON JOB: DATE 04122/08 Western States Fire Protection Company 7102 18051 AVE NE, STE A-105 - REDMOND, WA - 98052 WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALB/XIUERCITE /ALAIN/ DALLAS/ DECATUR /DENVER / DULUTH/HOUSTON /KANSAS CITY LASVEGAS / PAIMEAPOUS/ AWIENIX/ PORT1AND !RAPID CITY / ST. PAUL /SALT LAKE CM /5F-ATTLE • Phone: 425-881-0100 Fax 425-881-3030 PINK 646 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SHEET FP1 OF VICINITY MAP (Suite# 646) SCALE: NTS General Notes 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. WEST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE 9,-o. MATCH MALL EXISTING 4" MAIN o 1"\" h? o• ;`l P-26 1l. -o. CL rn :-\;:411 N 02 c)::°-:kv:f4:111-21 ® ®i>0 EMI =2 IC9 =1 t® to 1621 PINK Remote Area: Retail # 646 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM / Ft' for 925.62 Ft' SPRINKLER Reliable Model G4A ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER. SYSTEM REQUIRES: 450.15 GPM © 103.4 PSI . At time of Design 11'-O" CLG.=38.5% AREA REDUCTION P-26 Fe -4' P•28 0 P-26 ji I 11* -0' 1 P-26 L1P-120' Ij EXISTING 4" MAIN 1-31/2 Ordinary Group II.0.20gp:nlft2 for 922.00ft2 FIRE SPRINKLER SYSTEM 1/8"=1'-0" F� TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD k: CEILING TILE FLEXHEAD DETAIL NOT TO SCALE FIG.909 SWIVEL SWAY BRACE FITTING 3I8' KWIK BOLT (21M' EMBED LENGTH) FIG.1000 "FAST CLAMP' SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE 3�57�911 FIG.4A PIPE CLAMP FOR SWAY BRACE FIG.909 NO -THREAD SW NEL SWAY BRACE ATTACHMENT 319' KWIK BOLT (2 1W EMBED LENGTH) 9 i a LATERAL BRANCHLINE RESTRAINT I a c I NON -THREADED BRACE PIPE BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III N / HILT! Kwik Bol II / ` Drilled Anchor r/L► �, / / Y Cut Rod Lgth Rounded to Nearest Inch Rod Coupling —� All Thread � Rod Swivel Ring Pipe Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE 3-S/32_ z w z 0 Adam Kantner 2 a w m 0 PINNACLE CONSTRUCTION INC. CONTRACTOR: SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE HYDRAULIC REFERENCE POINT t R3615 10 5.6 Pendent %Z' Chrome 155°F F1 FR Semi -Recessed APPROVAL: CITY OF TUKWILA R5415 46 5.6 Pendent White 155°F Reliable G4A Concealed CONT. NO.: KS0319 Total = 56 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RESTRAINT SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 06/19/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA- 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE /AUSTIN /D LLLAs/ DECATUR !DENVER / DULUTH /HOUSTON /KANSAS CITY LAS VEGAS/MEI EBPOLIS /PHOENIX/PORTLAND/ RAPID CITY / ST. PAIL/SALT LAKE CRY/SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 PINK 646 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SHEET FP1 OF 1