Loading...
HomeMy WebLinkAboutPP - 652 SOUTHCENTER MALL - UNKNOWN TENANT - PERMITS AND PLANS652 SOUTHCENTER MALL ASSOCIATED PERMITS 15-S-172 4ist SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King \ Co. Assessor's Tax No.: Site Address: (J252, Cjov�\AC-eY1�-P�' mo`, Suite Number: , Floor: Tenant Name: Le\` New Tenant? ❑ - Yes ❑ - No Property Owner's Name: , '\'Yc -V / I lQ Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: J.e...j\ca,`nom-, Day Telephone: LA -Li Si '7 WI Company Name: Ci `�\.)3A .VV `-e.-\�� n / Mc_, Mailing Address: Po Do( \Z,13 1 1 1f z I 1.0N-% 1$ 2, City E-mail Address: \�Gsk CA� �Ol1.DYi�• r0 cm Fax Number: '/2S -4/4(096—' Total number of newt/relocated devices or sprinkler heads: J112.— Valuation of Project (contractor's bid price): $ LAPM. Scope of Work (please provide detailed information): ?1o9 Czliecid.s PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER O)(t AUT RIZED AGENT: Signature: C Print Name: Date: 1D '12- AS Day Telephone: t -A2 -S' (Aso t 7(0 (ci Plan Permit App.doc 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Lolli & Pops 652 Southcenter Mall Permit No.: 15-S-172 Date: October 21, 2015 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 tt.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work_ • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. 0 Without Comments j:' As Noted in Red Per The Attached Letter ''nese plans have been reviewed by The Tukwila Fire �ktention Bureau for conformance with current City • ndards. Acceptance is subject to errors and Assions which do not authorize violations of adopted 3n -dards and ordinances. The responsibility for the j_,aequacy of design rests totally with the designer. Ajcditions, deletions or revisions to these drawings after rtis date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is stil);.ac to field test and inspection by The Tukwila fire P eventIon f?;:.:+eau. Date: /0--a / / S.-- .6y: ,4-4-r45 C4-4led i>n rt'cj ?iCeeeot TU WI A-- FIR DE• ?ease -,r.11 205-575-4,':07 Lnd ,jivethis Fire Permit No. Is,lS•,/7�, and exact:i ,,*. ss for -lawn or t' = =loll approviA. 2 EL -10 0 AFF $ TIN CEILING TILE JTYP) EL = 11r-0" A.F.F. sio GWB BULKHEAD EL = 1070" A.F.F. MALL COMMON AREA NORTH REFLECTED. CEILING PLAN q _ SCALE:,, p s AbJACENT.TENANT AREA Design per NFPA 13, Ordinary Hazard — Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 13 — Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 • 17 — Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents I/2 x 1/2 • 2 — Plug existing 32 — Total Corrugated stainless steel hose with stainless steel bral 110 Multi -Port Bracket • • • • • • • Adjustable Hub FLEXHiita INDUSIAIe,r J Elbxhead omrriercial Ceiling Unit• • T -Bar Ceiling Installation • Model ##2024,2036,2048,2060,2672 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP DEAR/.0-CLAMP - WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS LOLLI & POPS - SPACE 652 WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTE John J. Abel 9780.0691 -Cts Level 3 Crown Fire Protection, Inc. 1 -. ■ .s a oY NORTH OCT 14 2015 TUKWILA FIRE - .2feefl.#233- • CRS N FIRE PROTECTION INCORPORATED - P.O.-BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 - • 0 scxAkce.Mer mall T1/4Mtvc"),\61 QV\ DATE: I D'7' 13 DRAWN: -1. SCALE: Ili c 4 652 SOUTHCENTER MALL ASSOCIATED PERMITS 15-S-172 4ist SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King \ Co. Assessor's Tax No.: Site Address: (J252, Cjov�\AC-eY1�-P�' mo`, Suite Number: , Floor: Tenant Name: Le\` New Tenant? ❑ - Yes ❑ - No Property Owner's Name: , '\'Yc -V / I lQ Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: J.e...j\ca,`nom-, Day Telephone: LA -Li Si '7 WI Company Name: Ci `�\.)3A .VV `-e.-\�� n / Mc_, Mailing Address: Po Do( \Z,13 1 1 1f z I 1.0N-% 1$ 2, City E-mail Address: \�Gsk CA� �Ol1.DYi�• r0 cm Fax Number: '/2S -4/4(096—' Total number of newt/relocated devices or sprinkler heads: J112.— Valuation of Project (contractor's bid price): $ LAPM. Scope of Work (please provide detailed information): ?1o9 Czliecid.s PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER O)(t AUT RIZED AGENT: Signature: C Print Name: Date: 1D '12- AS Day Telephone: t -A2 -S' (Aso t 7(0 (ci Plan Permit App.doc 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Lolli & Pops 652 Southcenter Mall Permit No.: 15-S-172 Date: October 21, 2015 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 tt.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work_ • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. 0 Without Comments j:' As Noted in Red Per The Attached Letter ''nese plans have been reviewed by The Tukwila Fire �ktention Bureau for conformance with current City • ndards. Acceptance is subject to errors and Assions which do not authorize violations of adopted 3n -dards and ordinances. The responsibility for the j_,aequacy of design rests totally with the designer. Ajcditions, deletions or revisions to these drawings after rtis date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is stil);.ac to field test and inspection by The Tukwila fire P eventIon f?;:.:+eau. Date: /0--a / / S.-- .6y: ,4-4-r45 C4-4led i>n rt'cj ?iCeeeot TU WI A-- FIR DE• ?ease -,r.11 205-575-4,':07 Lnd ,jivethis Fire Permit No. Is,lS•,/7�, and exact:i ,,*. ss for -lawn or t' = =loll approviA. 2 EL -10 0 AFF $ TIN CEILING TILE JTYP) EL = 11r-0" A.F.F. sio GWB BULKHEAD EL = 1070" A.F.F. MALL COMMON AREA NORTH REFLECTED. CEILING PLAN q _ SCALE:,, p s AbJACENT.TENANT AREA Design per NFPA 13, Ordinary Hazard — Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 13 — Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 • 17 — Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents I/2 x 1/2 • 2 — Plug existing 32 — Total Corrugated stainless steel hose with stainless steel bral 110 Multi -Port Bracket • • • • • • • Adjustable Hub FLEXHiita INDUSIAIe,r J Elbxhead omrriercial Ceiling Unit• • T -Bar Ceiling Installation • Model ##2024,2036,2048,2060,2672 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP DEAR/.0-CLAMP - WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS LOLLI & POPS - SPACE 652 WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTE John J. Abel 9780.0691 -Cts Level 3 Crown Fire Protection, Inc. 1 -. ■ .s a oY NORTH OCT 14 2015 TUKWILA FIRE - .2feefl.#233- • CRS N FIRE PROTECTION INCORPORATED - P.O.-BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 - • 0 scxAkce.Mer mall T1/4Mtvc"),\61 QV\ DATE: I D'7' 13 DRAWN: -1. SCALE: Ili c 4