HomeMy WebLinkAboutPP - 661 SOUTHCENTER MALL - ABERCROMBIE & FITCH COMPANY - PERMITS AND PLANS661 SOUTHCENTER MALL
ASSOCIATED PERMITS
14-F-071
14-S-047
40sitrior44
SITE LOCATION
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.:
Site Address: LA0. 1 C'erlie,r) Suite Number: 55to Floor:
Tenant Name:'(vro b\fin £ .\\-L� New Tenant? ❑ - Yes'- No
1j "1-Q
Property Owner's Name: \-e.\81._ ,1
rna�a�P�e4 ` apycrup
Mailing Address:
CONTACT PERSON -if there are
questions
about the submittal.
Name: jef--x--T_LX ?Ok))/15Y)
City State Zip
Day Telephone: 4'ZS• yg1 7 i
Company Name: Crown 'Pyre. 1( c'l
Mailing Address: ?I Ox \2\ l�j I l �'e'P] _, U.D/ ei so R2_,
City State Zip
E-mail Address:.StS1CA0 abwr . Cowl Fax Number: 4/ .4118/ f i9
Total number of new/relocated devices or sprinkler heads: \ �—
Valuation of Project (contractor's bid price): $ CU.). CO
Scope of Work (please provide detailed information):
vice, )r\earks C(o) heads
PERMIT APPLICATION NOTES
Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING 0
Signature
Print Name:
Plan Permit App.doc
ER OR AUTHORIZED AGENT:
.SS1CA�o1�tY��
Day Telephone:
Date: 3 17/4
Z- •`. fig./ -7 q
1/2/13 TFD FP Form 8
SITE LOCATION
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.: 9202470010
Site Address: 661 Southcenter Mall Suite Number: 556 Floor:
Tenant Name: Abercrombie & Fitch New Tenant? Yes ❑ - No
Property owner's Name: Westfield Property Tax Dept.
Mailing Address:
POB 130940, Carlsbad, CA 92013
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: Karina Veliz Day Telephone: 206.349.5889
Company Name: Guardian Security Systems
Mailing Address:1743 First Ave South, Seattle, WA 98134
kveliz@guardiansecurity.com City State Zip
E-mail Address: Fax Number: 206.628.4990
Total number of new/relocated devices or sprinkler heads: 32
Valuation of Project (contractor's bid price): $ 8500.
Scope of Work (please provide detailed information): Adding 32 devices to existing FACP.
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR AU,�
TjHO
RI
Z
(E t GENT:
a.a
Signature:
Date:
. 9, IL(
Print Name: Karina Veliz Day Telephone: 206.349.5889
Plan Permit App.doc
1/2/13 TFD FP Form 8
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Abercrombie & Fitch
661 Southcenter Mall
Permit No.: 14-S-047
Date: March 19, 2014
Reviewer: Al Metzler
Fire Protection Project Coordinator
(206) 575-4407 option # 2 (Inspection Requests)
(206) 971-8718 (Plan Review Questions)
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the last length of
pipe but within 6' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40 ' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2 for pipe size 2 1/2 inches and larger.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-02, section 9.6.2.6.2 (e).
• Ceilings used for flex drop attachments shall comply with ASTM C 635 and
ASTM C 636 per section 9.2.1.3.3.2.
• Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a
suspended ceiling, a hanger(s) attached to the structure shall be required to
ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3).
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
• Comply with obstructed/non-obstructed construction rules for sprinkler head
placement.
• Sprinkler heads spaced closer than 6 ft. apart must be baffled.
• Modifications involving 20 or more sprinkler heads require hydrostatic test and
system isolation if necessary.
• For dry pipe and double interlock preaction systems in addition to the standard
hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24
hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the
24 hours shall be corrected.
All code references are NFPA 13, 2010 Edition.
ABERCIZ M 1E FIT H
FIRE ALARM SYSTEM ADDITION
TUKWILA, WASHINGTON
SHEET \UV3ESHEET TITLE
FA -01
SYSTE
V
V
ATIO\ & SI\GLE LI\E DIAbAV
FA -02
TYPICAL WIC \G
A\D V
OU\TI\G DAGAVS & CALCULATIO\S
FA -03
FRE ALAN
SYSTEv PLA\
SHEET INDEX
QUANTITY
EX
4
4
4
•1
16
3
SYMBOL DESCRIPTION
MODEL
MANUFACTURER BACKBOX
MOUNTING HEIGHT
BPS
REMOTE BOOSTER
POWER SUPPLY
PAD -3
SIEMENS
PAD-3-ENCL 66" A.F.F.
TO TOP
®D
AIR DUCT
HOUSING
FDBZ492-HR
HFP-11 DETECTOR
SIEMENS
DUCT HOUSING HVAC
DUCT WORKS
HT -M
SINGLE INPUT
INTERFACE MODULE
HTRI-M
SIEMENS
4S BOX
VERIFY
IN FIELD
TSM
DUCT DETECTOR
TEST SWITCH
TSM -1
SIEMENS
1 -GANG BOX
VERIFY
IN FIELD
HT -R
INTERFACE MODULE
WITH RELAY
HTRI-R
SIEMENS
4S BOX
VERIFY
IN F=IELD
FIRE ALARM
al HORN STROBE
(CEILING MOUNT)
ZH-MC-CW
SIEMENS
4S BOX
CEILING
FIRE ALARM
STROBE
(CEILING MOUNT)
ZR -MC -CW
SIEMENS
4S BOX
CEILING
El JUNCTION BOX
F.B.O.
F.B.O.
N/A
VERIFY
IN FIELD
A.F.F.
ABOVE FINISHED
FLOOR
N/A
N/A
N/A
N/A
EX
EXISTING
DEVICE
N/A
N/A
N/A
N/A
F.B.O.
FURNISHED BY
OTHERS
N/A
N/A
N/A
N/A
N/A
NOT
APPLICABLE
N/A
N/A
N/A
N/A
RED
AS BUILT
ADD OR CHANGE
N/A
N/A
N/A
N/A
GREEN
AS BUILT
REMOVE
N/A
N/A
N/A
N/A
BLUE
AS BUILT
NOTES TO CAD
N/A
N/A
N/A
N/A
SYMBOLS L EGEND
WISE SCHEDULE A\3 CO\DUIT FILL CHAT
WIRE DESIGNATION
SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE
C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET)
D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET)
P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET)
S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR! RED (JACKET)
S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR' RED (JACKET)
V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR I, RED (JACKET)
V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR-` RED (JACKET)
I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET)
CONDUIT FILL CHART
NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS ' AREA
TWO 600V #12 AWG THHN/THWN .244 O.D. .0467
TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346
TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. '.0191
CONDUIT FILL ,
CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE
ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM
THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE.
CONDUIT SIZE MAXIMUM FILL
1/2" .12 SQUARE INCH
3/4" .21 SQUARE INCH
1" .34 SQUARE INCH
1-1/8" .60 SQUARE INCH
1-1/2" .82 SQUARE INCH
2" 1.34 SQUARE INCH
FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4.
SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END
FOR SIEMENS SYSTEM:
DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED
WITH DEVICES ADDRESS.
1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS
DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1.
2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED.
3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL.,
BRANCHING IS PERMISSIBLE
4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL
ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION.
5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS,
STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT)
ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION.
6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT
AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1
7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY,
TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY,
AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION.
8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MAR
DRAWINGS FOR "AS BUILT" PURPOSES.
9, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT
SHEETS AND/OR INSTALLATION INSTRUCTIONS.
CED
10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS
MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72,
SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER
SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT
DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN.
11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT
OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS.
12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE
ACTIVATION DEVICE.
13. ALL PANEL NUMBERS AND CIRCUITS WILL DE ON THE RECORD DRAWINGS SET.
14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY
GENERATOR.
15. PER \FPA 72 SECTIO\ 5-3.6.1.3 DETECTO;S SHALL NOT BE INSTALLED UNTIL AFTER
THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL.
EXCEPTIO\: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION
FOR PROTECTION DURING CONSTRUCTION.
DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL
TRADES SHALL BE CLEA\ED OR REPLACED IN ACCORDANCE WITH NFPA 72
CHAPTER 7.
16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT
AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR
OTHER BACK BOXES OF DIFFERENT CIRCUITS.
17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND
AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO
FINAL EQUIPMENT TRIM.
18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A
PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP.
19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE
OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES
AFTER COMPLETION OF THEIR INSTALLATION.
20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH
IT IS LOCATED.
21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT.
22.
23.
NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING
PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE
INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING
FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE
ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT
CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEv1BLY (I.E.,
MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY.
NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE
ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES.
THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE
CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM
SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 NM (1 FT) WHERE
THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE
CABLE IS INSTALLED
macys
4 LEVELS
EP
El Without Comments
As Noted in Red
Cl Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau for conformance with current City
standards, Acceptance is subject to errors and
omissions which do not authorize violations of adopted
standards and ordinances The responsibility for the
adequacy of design rests totally with the designer,
Additions, deletions or revisions to these drawings after
this date will void this acceptance and will require a
resubmittal of revised drawings for subsequent approval.
Final acceptance Is subject to field test and inspection by
The Tukwila fire Prevention
Date: -.Br
U.
TUKWILA FIRE DEPARTMENT
Piease call 206-575-4407 and
give this Fire Permit No.
/y -F-071
and exact address for shut-
down or restoration approval.
\ NORDSTROM
3 LEVELS
71,275sf
i_r � C",I�RCSSD • A�-CT%•may
BEN RIDGE
:WE ERA
ARiUMERIE
TENANT
SPACE d 728
Li
IR TO TO CO i x
TINDER BOX I LL
BLOWN AWAY OAR
t�� LAIi THE RARE ROOT CIN_CULAR
8
0
CCS
JANES
BOUTIQUE
G.N.C.
HUTIN CLASS
Irsdi�vt Yt . S
Li
A
SILVER A COLD
NOTICE
4 completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testing
�.1
A
KING COUNTY LIBRARY
D5�
SS
AVON
A ONI
PNC,BANK . UFIGLM1S#
DESIGN
CAATEL�
STJLICKS
EAIDTINS
JCPenney
3 LEVELS
VERIZON WIRELESS
276,4680
tIAPONAL UNIVERSITY
I BEAUI, •AURAS
J
ABERCROMBIE & FITCH
#661 / SPACE 556
KEY PLAN
TO HOUSE
J -BOX
TO HOUSE
EXISTING
POWER SUPPLY
TO HOUSE
EXISTING
POWER SUPPLY
FLAG NOTES:
FIELD LOCATE RELAY MODULE FOR
BACKGROUND MUSIC INTERFACE.
DUCT DETECTOR, MONITOR MODULE & TEST
SWITCH LOCATIONS TO BE FIELD VERIFIED BY
MECHANICAL, ELECTRICAL AND FIRE ALARM
CONTRACTORS.
DOORS FOR DRESSING ROOMS ARE HALF SIZE
HEIGHT DOORS ONLY.
30cd 30cd 15cd 75cd 30cd
S2-1 S2-2
S2-3
S2-4
30cd 30cd 30cd 30cd
S2-5
30cd 30cd 15cd 15cd 30cd
S2-6
EOL
S1
S2-7
S2-8
S2-9
EOL
52-10 S2
75cd 30cd 30cd 30cd 30cd
WIRE DESIGNATION
GENERAL NOTES
SINGLE LINE DIAGRAM
PAID
APR eq 21114
TUK.VILA FIRE
de 233".
No
0
1743 1ST AVE. SO., SEATTLE, WASHINGTON
FAX (206) 628-4990
TEL. (206) 622-6545
1. I- L./ I. L V I I V I YV
NO DATE DESCRIPTION REV. BY:
0
a
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
no NUMBER• Q��Z-' '
SHOP DRAWINGS
04/08/14
<<<<<,
:I: Ll]
U co
cl
LL g w rn
0:0 V22 cc 'I
15 cc<
QO
CC Z
Q 1223
aC w EEW g
w
m o�
Q
oor
CID
'SCALE: NOT TO SCALE
DRAWN BY:
D. GARCIA
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
no NUMBER• Q��Z-' '
Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
SHEET
FA -012
Current Load:
Standby:
Alarm:
Device Type
Qty
Amps
Total
Amps
Total
HFP-11 Detector
0.0015
0.0060
0.0015
0.0060
FDBZ492 Duct Housing
4
0.0001
0.0004
0.0500
0.2000
HTR -R Module
0.0010
0.0010
0.0010
0.0010
HTRI-M Module
4
0.0015
0.0060
0.0015
0.006
0.0134
Amps
0.2130
Amps
Citr
Device Type
Qty
Amps
Total
Amps
Total
Main System Board
1
0.03
0.03
0.030
0.030
ZH-MC-CW c+a 15cd: •
7
0.087.
0.069
0.483
ZH-MC-CW @30cd
14
0.131
0.111
1.554
al -MC -CW @75cd
0.222
0.2
1.600
ZH-MC-CW @95cd
4
0.292
0.264
1.056
ZR -MC -CW Ca15cd
16,
0.069'
0,069
1.104
ZR -MC -CW @30cd
0.111
0.111
0.03
Amps.
5.827
Amps
Standby Current Load:
0.03
Amps
For 24 Hours =
0.720
Amp -hours.
Alarm Current Load:
5.827
Amps
For 5 Minute
0.489
Amp -hours
25% Derating=
1.512
Amp -hours
Total System Current Load:
1.512
Amp -hours
Notification Appliance Circuit Detail
PROJECT: ABERCROMBIE & FITCH
Panel: EXISTING PAD -3 POWER SUPPLY
Date: April 9, 2014
Wire Resistance 2.58
CURRENT TOTAL= ;2485.00
7 .. C -CW
@15cd ...
. _._.�. 30cd...
1 ZH-MC-CW @75cd
ZH-Mq-CW @95cd
1 ' ZR -MC -CW @15cd
C -CW @30cd
1 Total Wire Resistance (R )
Total . Device . Load,
Voltage Drop (E )
EOL.VOliage
(WL*2)*(R/ft); 1.65
Total Cct Load) 1.21
24 - E} 22.01
2
DEVICES
ZH-MC-CW @15cd! 87
74-Mc4W....@3Q0
, 131'
ZH-MC-CW @75cd 222
ii-MCCW @95cd _.:..:._....._: 292
ZR -MC -CW @15cd ! 69 138
-MC-CW @30cd ' 1.117
TOTAL
10 ' mA=
:Total Wire ResistanceIR
R
Total NC?ev ce Load, Arrips (
Voltage Drop (E )
EOL Voltage
WL* 2)*(Rift) ` 1.75
Total Cct Load}
(E=I*R) 2.24
24'- E) 21.76
SYSTEM CALCULATIONS
THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72.
THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX
DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED.
NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION.
DUCK OVER 3' WIDE:
SAMPLE TUBE MUST GO
THRU THE DUCT AND BE
CAPPED.
120VAC-60HZ
DEDICATEDDERGENCY-(
TUBE OUTLET
SAMPLING
TUBE INLET
SAMPLING
AT LEAST
SIX DUCT
WIDTHS
FROM BEND
DUCT DETECTOR MOUNTING DETAIL
NOTE FOR AMMONM. SPECF1CAMNS SFE PRODUCT D0a TA11Q1
*CONTACT RATINGS:
4.OA 0 125VAC
4.0A 0 304DC
fliN
OW N LL
CI
M NEXT DEVICE SMP 7 �r+
FROM XLS cONTRI . pate.a
LR PREY US ADDRESSABLE DEVICE -
GROUND
+�I J
HTRI-R
° O
NOTE:
FOR ADDITIONAL SPECIFICATIONS
SEE PRODUCT DOCUMENTATION.
00 00
PAD -3
ooEl
NPUr INPUT TROUBLE NACI NAC2 NAC3 NAC4 MDL
+1- 1 2+2- 2 NC C No + - + - + - + - + -
a
7
ZS ZS
CEILIN
TILE
00
SUPPORT
BRIDGE
4" SQUARE
DEEP BOX
CEILING
/- HORN STROBE
/
STROBE ONLY
DROP CEILING MOUNTING
HARD LID
CEILING
SUPPORT
BRIDGE
4" SQUARE
DEEP BOX
CEILING
HORN STROBE
STROBE ONLY
HARD LID MOUNTING
HORN STROBE & STROBE CEILING MOUNTING DETAIL
C -CABLE
C -CABLE
(-)
(+)
3.6k EOL
NAC 4 CIRCUIT
NAC 3CIRCUIT
NAC 2 CIRCUIT
EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL
(-)
(+)
HORN/STROBE
OR
STROBE ONLY
C �
HORN/STROBE
OR
STROBE ONLY
u
HORN/STROBE
OR
STROBE ONLY
TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL
TO NEXT
DEVICE OR
END OF LINE
TYPICAL WIRING AND MOUNTING DETAILS
FROM PREVIOUS
ADDRESSABLE 2
DEVICE
TB1
®®
NO
COM
NC
2 TO FAN
SHUTDOWN
EOLR
470
SWITCH + -
INPUT LED
TSM -1
HTRI-M
RED
BLK
+ 2TONEXT
00 _ 2ADDRESSABLE
DEVICE
ORG
ORG
GRN
NOTE:
FOR ADDITIONAL SPECIFICATIONS
SEE PRODUCT DOCUMENTATION.
TYPICAL DUCT DETECTOR/HTRI-M MODULE/TSM-1 SWITCH WIRING DETAIL
1`0
co
0
SO., SEATTLE, WASHINGTON
LL I
FAX (206) 628-4990
TEL. (206) 622-6545
I \L. L.L/'1VI-I I \lam V IVI VI `IV
NO DATE DESCRIPTION REV. BY:
DMG
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
Inn MI IAAIDCD. 0=07_ 1 .
SHOP DRAWINGS
04/08/14
<
<
<<
<
i
�c.) co
a
u_ 2 u)SS
�S FLI2 .>‹:6
w }0 <
��
2 cc 'La)
cc <
CC W Z0 Er- g
w
m �~
Q
CD
Z
0
or)
Q
W
O
C3
H
O
ozs
c.Dce°7
Cl -
'YALE: NOT TO SCALE
DRAWN BY:
D. GARCIA
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
Inn MI IAAIDCD. 0=07_ 1 .
% SHEET
FA -.02
Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
TO HOUIS )
EXIST,ING
POWER SUPPL
TO HOUSE
J -BOX
Cr)
FRAME LEDGE,
IMAGES, AND
SIGHAGE
r4EFER
FITTING 103 l
E,F, G &
laa SQ.. FT.
FITTIN 103
3, C 2D
222 SQ. FT.
BULLETIN BOARDS
CASI-MRAP
DEAD SPACE
39 SQ. FT.
r
10' IS 8' SALES
AREA FRAME
LF
GAR
BACKIAIRAP
BLF SI4V
VEST. 110
IIRROR
10' r 8' SALES
AREA FRAME
122 SO. F.
FIXED
HT -M
ITSM
WOMERS
SV7Eils
30a11
1,079 SO. FT.
WOMENS
i
004 SQ. FT.
4LF
1-1GR,
STG,
EArm- AiA
S1-9 Si
300
L
11:702,02604*020Z
TT)
10' x 8' SALES
AREA FRAME
R IC102
¶T L.
SW/. 14
SEC.
D—c)
1-1 Tr.
51-1V. 14
SEC.
RECESSED PUF'LEX
FLOOR RECEPTICAL, SEE
E L. ECT R ICA L DRAW NC/
IRROR ;31
10' .tt 8' ENTRY
VESTIBULE FRAM
30x4
NOV.
51-G. DECK
ABOVE
44t,J1.1.ETIN BP
I
101
272 SO. FT.
1.5PET
MEZZANINE
&)IRROR. 051
IRROR
TEL. PHONE
[MIRROR gl
BEV
rf.ACA
10" SALES
AEAAME
VST. 105
125 SO. FT.
S
1..1 1,, .0.
S2-7
Qc
CAS 1NRAP
?ENS
108
942 SQ. FT.
103
S24
1,0(1S SQ. FT,
30c1J
EOL
S2
ACKSAP
. _
ELEC.
ROOM
10' 3' SALES
AREA FRAME
10' 8' SALES
AREA FRAME
MIRRO
MflROR
DEAD SPACE
58 SQ. FT.
IRROR
ST. 11
rRtVi7E
3'.1AGE3, S1GI'JAGE
tin- nor) FAO
REFER TO r....Er 411.1
Roo:. 11
lI0OiI 11
no0.1 11
1,523 50. FT.
DN TO
MAIN FLOOR
RTTfl1G 103
J,
101 SO. FT.
MEZZANIN
S2-1
30cd
34
FIRE ALARM SYSTEM PLAN
FLAG NOTES:
FIELD LOCATE RELAY MODULE FOR
BACKGROUND MUSIC INTERFACE.
DUCT DETECTOR, MONITOR MODULE & TEST
SWITCH LOCATIONS TO BE FIELD VERIFIED BY
MECHANICAL, ELECTRICAL AND FIRE ALARM
CONTRACTORS.
DOORS FOR DRESSING ROOMS ARE HALF SIZE
HEIGHT DOORS ONLY.
N
N
cO
SO., SEATTLE, WASHINGTON
FAX (206) 628-4990
TEL. (206) 622-6545
I \ L_ /Th—J 1— / I I— V I •.1 I \ I I s.—J
NO DATE DESCRIPTION REV. BY:
0
a
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
t HID 1.1111,41DCD. 0 ,17___ 1 .
...\
SHOP DRAWINGS
04/08/14
'SCALE: 3/ 1 6-= 1 "0". `
DRAWN BY:
D. GARCIA
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
t HID 1.1111,41DCD. 0 ,17___ 1 .
r SHEET
FA -03
Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
MAKE SEAMLESS
TRANSITION TO
EXISTING CEILING
RETAINER STRAP VI•IERE REQUIRED
IN SEISMIC AREAS
TOP BEAM/ C -CLAMP
WITH SET SCREW
3/8' ALL THREAD ROD
PIPE SWIVEL RING
STEEL MIST/TRUSS
HANGER DETAIL
NTS
G.C. TO REINSTALL EXISTING
EXIT LIGHTS AFTER- PHASE •i
CONSTRUCTION
NEW LOCATION OF EXISTIBNG
RECESSED CAN LIGHT. EXTEND
EXISTING CIRCUIT TO NEW
LCOATION. REFER TO SECTION
FlexHead Sprinkler Drop
Corrugated stainless steel hose with stainless steel braid
available In 7, 3',4',5' & 6' legnths .
Multi -Port Bracket
• Adjustable Hub
o Without Comments
o As Noted in Red
lir Per The Attached Letter
These plans have been reviewed by The Tukwila. Fire
Prevention Bureau for conformance with current City.
standards. Acceptance is subject to errors and
omissions which do not authorize violations of adopted::.
standards and ordinances. The responsibility for the
adequacy of design rests totally with the designer.
Additions, deletions or revisions to these drawings after:
this date will void this acceptance and will require a'
resubmittal of revised drawings for subsequent approval..
Final acceptance is subjecttofield test and inspection by
The Tukwila Fire Prevention Bureau.
Date: 3-1 61--1 J gy
•
- Elexiieed'bomrnerciai Ceiling Unit
T -Bar Celli igInstallation •
Model #2024,2036,2048,2060,2072
G.C. TO REINSTALL EXISTING
EXIT LIGHTS AFTER PHASE 1
CONSTRUCTION
TUKW�WILA FIRE DEPARTMENT
Plea call 206.575=4407 and
give this Fire Permit No*
and exact addles for shut-
down or restorttion api 'vol.
�I
MAKE SEAMLESS
TRANSITION TO
EXISTING. CEILING --\;
1'
•
•1• •,J :.• r•=' .)••
L
•
NEW LOCATION OF. EXISTING TRACK
LIGHTING. REFER TO SECTION.
EXTEND EXISTING CIRCUIT TO NEW
LOCATION AND RECONNECT
NEW . CEILING IN RECESSED
ENTRY.
• 6 — Replace existing pendent with Reliable Model G5-56 Concealed Pendent 165° 1/2 x 1/2
(cut for new ceiling height using a Flexhead)
O 6 — Add Globe GL566IStandard Response Upright 155° 1/2 x 1/2
REFLECTED CEILING PLAN
' Z.
Abercrombie & Fitch
• SPACE #E-556
• LEVEL 1 OF 1
NEW LOCATION OF EXISTING TRACK -
LIGHTING. REFER TO SECTION.
EXTEND EXISTING CIRCUIT TO NEW
LOCATION AND RECONNECT
j.
• WASHINGTON STATE
FCERTIFICATE OF COMPETENCY "r
IRE PROTECTION SPRINKLER SYSTEMS. . •
CG Level 3
John J. Abe!
Protection, Inc.
9760-0591•
Crown Fire
C13 FP
r••
°■
• X. Signature - •
Nuarlse mm mm -1
r•.
r. -
r
A
•
CROWN
FIRE PROTECTION
INCORPORATED •
P.O. BOX 12113
HILL CREEK, WASHINGTON 98082-0113
PH. (425)481-7669
•
Abercrombie & Fitch
Southcenter Mall
661 Southcenter Mall
Space 556
Tukwila, WA 98188
FAIR.
MAR 18.'2014
TWIN. LA FIRE"
'27975 ,,,ZO3—
DATE:
DRAWN:
v:
SCALE:
fly►
•
661 SOUTHCENTER MALL
ASSOCIATED PERMITS
14-F-071
14-S-047
40sitrior44
SITE LOCATION
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.:
Site Address: LA0. 1 C'erlie,r) Suite Number: 55to Floor:
Tenant Name:'(vro b\fin £ .\\-L� New Tenant? ❑ - Yes'- No
1j "1-Q
Property Owner's Name: \-e.\81._ ,1
rna�a�P�e4 ` apycrup
Mailing Address:
CONTACT PERSON -if there are
questions
about the submittal.
Name: jef--x--T_LX ?Ok))/15Y)
City State Zip
Day Telephone: 4'ZS• yg1 7 i
Company Name: Crown 'Pyre. 1( c'l
Mailing Address: ?I Ox \2\ l�j I l �'e'P] _, U.D/ ei so R2_,
City State Zip
E-mail Address:.StS1CA0 abwr . Cowl Fax Number: 4/ .4118/ f i9
Total number of new/relocated devices or sprinkler heads: \ �—
Valuation of Project (contractor's bid price): $ CU.). CO
Scope of Work (please provide detailed information):
vice, )r\earks C(o) heads
PERMIT APPLICATION NOTES
Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING 0
Signature
Print Name:
Plan Permit App.doc
ER OR AUTHORIZED AGENT:
.SS1CA�o1�tY��
Day Telephone:
Date: 3 17/4
Z- •`. fig./ -7 q
1/2/13 TFD FP Form 8
SITE LOCATION
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.: 9202470010
Site Address: 661 Southcenter Mall Suite Number: 556 Floor:
Tenant Name: Abercrombie & Fitch New Tenant? Yes ❑ - No
Property owner's Name: Westfield Property Tax Dept.
Mailing Address:
POB 130940, Carlsbad, CA 92013
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: Karina Veliz Day Telephone: 206.349.5889
Company Name: Guardian Security Systems
Mailing Address:1743 First Ave South, Seattle, WA 98134
kveliz@guardiansecurity.com City State Zip
E-mail Address: Fax Number: 206.628.4990
Total number of new/relocated devices or sprinkler heads: 32
Valuation of Project (contractor's bid price): $ 8500.
Scope of Work (please provide detailed information): Adding 32 devices to existing FACP.
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR AU,�
TjHO
RI
Z
(E t GENT:
a.a
Signature:
Date:
. 9, IL(
Print Name: Karina Veliz Day Telephone: 206.349.5889
Plan Permit App.doc
1/2/13 TFD FP Form 8
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Abercrombie & Fitch
661 Southcenter Mall
Permit No.: 14-S-047
Date: March 19, 2014
Reviewer: Al Metzler
Fire Protection Project Coordinator
(206) 575-4407 option # 2 (Inspection Requests)
(206) 971-8718 (Plan Review Questions)
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the last length of
pipe but within 6' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40 ' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2 for pipe size 2 1/2 inches and larger.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-02, section 9.6.2.6.2 (e).
• Ceilings used for flex drop attachments shall comply with ASTM C 635 and
ASTM C 636 per section 9.2.1.3.3.2.
• Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a
suspended ceiling, a hanger(s) attached to the structure shall be required to
ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3).
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
• Comply with obstructed/non-obstructed construction rules for sprinkler head
placement.
• Sprinkler heads spaced closer than 6 ft. apart must be baffled.
• Modifications involving 20 or more sprinkler heads require hydrostatic test and
system isolation if necessary.
• For dry pipe and double interlock preaction systems in addition to the standard
hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24
hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the
24 hours shall be corrected.
All code references are NFPA 13, 2010 Edition.
ABERCIZ M 1E FIT H
FIRE ALARM SYSTEM ADDITION
TUKWILA, WASHINGTON
SHEET \UV3ESHEET TITLE
FA -01
SYSTE
V
V
ATIO\ & SI\GLE LI\E DIAbAV
FA -02
TYPICAL WIC \G
A\D V
OU\TI\G DAGAVS & CALCULATIO\S
FA -03
FRE ALAN
SYSTEv PLA\
SHEET INDEX
QUANTITY
EX
4
4
4
•1
16
3
SYMBOL DESCRIPTION
MODEL
MANUFACTURER BACKBOX
MOUNTING HEIGHT
BPS
REMOTE BOOSTER
POWER SUPPLY
PAD -3
SIEMENS
PAD-3-ENCL 66" A.F.F.
TO TOP
®D
AIR DUCT
HOUSING
FDBZ492-HR
HFP-11 DETECTOR
SIEMENS
DUCT HOUSING HVAC
DUCT WORKS
HT -M
SINGLE INPUT
INTERFACE MODULE
HTRI-M
SIEMENS
4S BOX
VERIFY
IN FIELD
TSM
DUCT DETECTOR
TEST SWITCH
TSM -1
SIEMENS
1 -GANG BOX
VERIFY
IN FIELD
HT -R
INTERFACE MODULE
WITH RELAY
HTRI-R
SIEMENS
4S BOX
VERIFY
IN F=IELD
FIRE ALARM
al HORN STROBE
(CEILING MOUNT)
ZH-MC-CW
SIEMENS
4S BOX
CEILING
FIRE ALARM
STROBE
(CEILING MOUNT)
ZR -MC -CW
SIEMENS
4S BOX
CEILING
El JUNCTION BOX
F.B.O.
F.B.O.
N/A
VERIFY
IN FIELD
A.F.F.
ABOVE FINISHED
FLOOR
N/A
N/A
N/A
N/A
EX
EXISTING
DEVICE
N/A
N/A
N/A
N/A
F.B.O.
FURNISHED BY
OTHERS
N/A
N/A
N/A
N/A
N/A
NOT
APPLICABLE
N/A
N/A
N/A
N/A
RED
AS BUILT
ADD OR CHANGE
N/A
N/A
N/A
N/A
GREEN
AS BUILT
REMOVE
N/A
N/A
N/A
N/A
BLUE
AS BUILT
NOTES TO CAD
N/A
N/A
N/A
N/A
SYMBOLS L EGEND
WISE SCHEDULE A\3 CO\DUIT FILL CHAT
WIRE DESIGNATION
SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE
C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET)
D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET)
P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET)
S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR! RED (JACKET)
S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR' RED (JACKET)
V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR I, RED (JACKET)
V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR-` RED (JACKET)
I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET)
CONDUIT FILL CHART
NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS ' AREA
TWO 600V #12 AWG THHN/THWN .244 O.D. .0467
TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346
TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. '.0191
CONDUIT FILL ,
CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE
ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM
THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE.
CONDUIT SIZE MAXIMUM FILL
1/2" .12 SQUARE INCH
3/4" .21 SQUARE INCH
1" .34 SQUARE INCH
1-1/8" .60 SQUARE INCH
1-1/2" .82 SQUARE INCH
2" 1.34 SQUARE INCH
FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4.
SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END
FOR SIEMENS SYSTEM:
DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED
WITH DEVICES ADDRESS.
1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS
DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1.
2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED.
3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL.,
BRANCHING IS PERMISSIBLE
4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL
ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION.
5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS,
STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT)
ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION.
6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT
AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1
7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY,
TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY,
AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION.
8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MAR
DRAWINGS FOR "AS BUILT" PURPOSES.
9, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT
SHEETS AND/OR INSTALLATION INSTRUCTIONS.
CED
10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS
MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72,
SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER
SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT
DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN.
11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT
OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS.
12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE
ACTIVATION DEVICE.
13. ALL PANEL NUMBERS AND CIRCUITS WILL DE ON THE RECORD DRAWINGS SET.
14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY
GENERATOR.
15. PER \FPA 72 SECTIO\ 5-3.6.1.3 DETECTO;S SHALL NOT BE INSTALLED UNTIL AFTER
THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL.
EXCEPTIO\: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION
FOR PROTECTION DURING CONSTRUCTION.
DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL
TRADES SHALL BE CLEA\ED OR REPLACED IN ACCORDANCE WITH NFPA 72
CHAPTER 7.
16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT
AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR
OTHER BACK BOXES OF DIFFERENT CIRCUITS.
17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND
AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO
FINAL EQUIPMENT TRIM.
18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A
PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP.
19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE
OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES
AFTER COMPLETION OF THEIR INSTALLATION.
20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH
IT IS LOCATED.
21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT.
22.
23.
NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING
PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE
INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING
FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE
ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT
CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEv1BLY (I.E.,
MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY.
NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE
ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES.
THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE
CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM
SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 NM (1 FT) WHERE
THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE
CABLE IS INSTALLED
macys
4 LEVELS
EP
El Without Comments
As Noted in Red
Cl Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau for conformance with current City
standards, Acceptance is subject to errors and
omissions which do not authorize violations of adopted
standards and ordinances The responsibility for the
adequacy of design rests totally with the designer,
Additions, deletions or revisions to these drawings after
this date will void this acceptance and will require a
resubmittal of revised drawings for subsequent approval.
Final acceptance Is subject to field test and inspection by
The Tukwila fire Prevention
Date: -.Br
U.
TUKWILA FIRE DEPARTMENT
Piease call 206-575-4407 and
give this Fire Permit No.
/y -F-071
and exact address for shut-
down or restoration approval.
\ NORDSTROM
3 LEVELS
71,275sf
i_r � C",I�RCSSD • A�-CT%•may
BEN RIDGE
:WE ERA
ARiUMERIE
TENANT
SPACE d 728
Li
IR TO TO CO i x
TINDER BOX I LL
BLOWN AWAY OAR
t�� LAIi THE RARE ROOT CIN_CULAR
8
0
CCS
JANES
BOUTIQUE
G.N.C.
HUTIN CLASS
Irsdi�vt Yt . S
Li
A
SILVER A COLD
NOTICE
4 completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testing
�.1
A
KING COUNTY LIBRARY
D5�
SS
AVON
A ONI
PNC,BANK . UFIGLM1S#
DESIGN
CAATEL�
STJLICKS
EAIDTINS
JCPenney
3 LEVELS
VERIZON WIRELESS
276,4680
tIAPONAL UNIVERSITY
I BEAUI, •AURAS
J
ABERCROMBIE & FITCH
#661 / SPACE 556
KEY PLAN
TO HOUSE
J -BOX
TO HOUSE
EXISTING
POWER SUPPLY
TO HOUSE
EXISTING
POWER SUPPLY
FLAG NOTES:
FIELD LOCATE RELAY MODULE FOR
BACKGROUND MUSIC INTERFACE.
DUCT DETECTOR, MONITOR MODULE & TEST
SWITCH LOCATIONS TO BE FIELD VERIFIED BY
MECHANICAL, ELECTRICAL AND FIRE ALARM
CONTRACTORS.
DOORS FOR DRESSING ROOMS ARE HALF SIZE
HEIGHT DOORS ONLY.
30cd 30cd 15cd 75cd 30cd
S2-1 S2-2
S2-3
S2-4
30cd 30cd 30cd 30cd
S2-5
30cd 30cd 15cd 15cd 30cd
S2-6
EOL
S1
S2-7
S2-8
S2-9
EOL
52-10 S2
75cd 30cd 30cd 30cd 30cd
WIRE DESIGNATION
GENERAL NOTES
SINGLE LINE DIAGRAM
PAID
APR eq 21114
TUK.VILA FIRE
de 233".
No
0
1743 1ST AVE. SO., SEATTLE, WASHINGTON
FAX (206) 628-4990
TEL. (206) 622-6545
1. I- L./ I. L V I I V I YV
NO DATE DESCRIPTION REV. BY:
0
a
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
no NUMBER• Q��Z-' '
SHOP DRAWINGS
04/08/14
<<<<<,
:I: Ll]
U co
cl
LL g w rn
0:0 V22 cc 'I
15 cc<
QO
CC Z
Q 1223
aC w EEW g
w
m o�
Q
oor
CID
'SCALE: NOT TO SCALE
DRAWN BY:
D. GARCIA
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
no NUMBER• Q��Z-' '
Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
SHEET
FA -012
Current Load:
Standby:
Alarm:
Device Type
Qty
Amps
Total
Amps
Total
HFP-11 Detector
0.0015
0.0060
0.0015
0.0060
FDBZ492 Duct Housing
4
0.0001
0.0004
0.0500
0.2000
HTR -R Module
0.0010
0.0010
0.0010
0.0010
HTRI-M Module
4
0.0015
0.0060
0.0015
0.006
0.0134
Amps
0.2130
Amps
Citr
Device Type
Qty
Amps
Total
Amps
Total
Main System Board
1
0.03
0.03
0.030
0.030
ZH-MC-CW c+a 15cd: •
7
0.087.
0.069
0.483
ZH-MC-CW @30cd
14
0.131
0.111
1.554
al -MC -CW @75cd
0.222
0.2
1.600
ZH-MC-CW @95cd
4
0.292
0.264
1.056
ZR -MC -CW Ca15cd
16,
0.069'
0,069
1.104
ZR -MC -CW @30cd
0.111
0.111
0.03
Amps.
5.827
Amps
Standby Current Load:
0.03
Amps
For 24 Hours =
0.720
Amp -hours.
Alarm Current Load:
5.827
Amps
For 5 Minute
0.489
Amp -hours
25% Derating=
1.512
Amp -hours
Total System Current Load:
1.512
Amp -hours
Notification Appliance Circuit Detail
PROJECT: ABERCROMBIE & FITCH
Panel: EXISTING PAD -3 POWER SUPPLY
Date: April 9, 2014
Wire Resistance 2.58
CURRENT TOTAL= ;2485.00
7 .. C -CW
@15cd ...
. _._.�. 30cd...
1 ZH-MC-CW @75cd
ZH-Mq-CW @95cd
1 ' ZR -MC -CW @15cd
C -CW @30cd
1 Total Wire Resistance (R )
Total . Device . Load,
Voltage Drop (E )
EOL.VOliage
(WL*2)*(R/ft); 1.65
Total Cct Load) 1.21
24 - E} 22.01
2
DEVICES
ZH-MC-CW @15cd! 87
74-Mc4W....@3Q0
, 131'
ZH-MC-CW @75cd 222
ii-MCCW @95cd _.:..:._....._: 292
ZR -MC -CW @15cd ! 69 138
-MC-CW @30cd ' 1.117
TOTAL
10 ' mA=
:Total Wire ResistanceIR
R
Total NC?ev ce Load, Arrips (
Voltage Drop (E )
EOL Voltage
WL* 2)*(Rift) ` 1.75
Total Cct Load}
(E=I*R) 2.24
24'- E) 21.76
SYSTEM CALCULATIONS
THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72.
THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX
DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED.
NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION.
DUCK OVER 3' WIDE:
SAMPLE TUBE MUST GO
THRU THE DUCT AND BE
CAPPED.
120VAC-60HZ
DEDICATEDDERGENCY-(
TUBE OUTLET
SAMPLING
TUBE INLET
SAMPLING
AT LEAST
SIX DUCT
WIDTHS
FROM BEND
DUCT DETECTOR MOUNTING DETAIL
NOTE FOR AMMONM. SPECF1CAMNS SFE PRODUCT D0a TA11Q1
*CONTACT RATINGS:
4.OA 0 125VAC
4.0A 0 304DC
fliN
OW N LL
CI
M NEXT DEVICE SMP 7 �r+
FROM XLS cONTRI . pate.a
LR PREY US ADDRESSABLE DEVICE -
GROUND
+�I J
HTRI-R
° O
NOTE:
FOR ADDITIONAL SPECIFICATIONS
SEE PRODUCT DOCUMENTATION.
00 00
PAD -3
ooEl
NPUr INPUT TROUBLE NACI NAC2 NAC3 NAC4 MDL
+1- 1 2+2- 2 NC C No + - + - + - + - + -
a
7
ZS ZS
CEILIN
TILE
00
SUPPORT
BRIDGE
4" SQUARE
DEEP BOX
CEILING
/- HORN STROBE
/
STROBE ONLY
DROP CEILING MOUNTING
HARD LID
CEILING
SUPPORT
BRIDGE
4" SQUARE
DEEP BOX
CEILING
HORN STROBE
STROBE ONLY
HARD LID MOUNTING
HORN STROBE & STROBE CEILING MOUNTING DETAIL
C -CABLE
C -CABLE
(-)
(+)
3.6k EOL
NAC 4 CIRCUIT
NAC 3CIRCUIT
NAC 2 CIRCUIT
EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL
(-)
(+)
HORN/STROBE
OR
STROBE ONLY
C �
HORN/STROBE
OR
STROBE ONLY
u
HORN/STROBE
OR
STROBE ONLY
TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL
TO NEXT
DEVICE OR
END OF LINE
TYPICAL WIRING AND MOUNTING DETAILS
FROM PREVIOUS
ADDRESSABLE 2
DEVICE
TB1
®®
NO
COM
NC
2 TO FAN
SHUTDOWN
EOLR
470
SWITCH + -
INPUT LED
TSM -1
HTRI-M
RED
BLK
+ 2TONEXT
00 _ 2ADDRESSABLE
DEVICE
ORG
ORG
GRN
NOTE:
FOR ADDITIONAL SPECIFICATIONS
SEE PRODUCT DOCUMENTATION.
TYPICAL DUCT DETECTOR/HTRI-M MODULE/TSM-1 SWITCH WIRING DETAIL
1`0
co
0
SO., SEATTLE, WASHINGTON
LL I
FAX (206) 628-4990
TEL. (206) 622-6545
I \L. L.L/'1VI-I I \lam V IVI VI `IV
NO DATE DESCRIPTION REV. BY:
DMG
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
Inn MI IAAIDCD. 0=07_ 1 .
SHOP DRAWINGS
04/08/14
<
<
<<
<
i
�c.) co
a
u_ 2 u)SS
�S FLI2 .>‹:6
w }0 <
��
2 cc 'La)
cc <
CC W Z0 Er- g
w
m �~
Q
CD
Z
0
or)
Q
W
O
C3
H
O
ozs
c.Dce°7
Cl -
'YALE: NOT TO SCALE
DRAWN BY:
D. GARCIA
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
Inn MI IAAIDCD. 0=07_ 1 .
% SHEET
FA -.02
Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
TO HOUIS )
EXIST,ING
POWER SUPPL
TO HOUSE
J -BOX
Cr)
FRAME LEDGE,
IMAGES, AND
SIGHAGE
r4EFER
FITTING 103 l
E,F, G &
laa SQ.. FT.
FITTIN 103
3, C 2D
222 SQ. FT.
BULLETIN BOARDS
CASI-MRAP
DEAD SPACE
39 SQ. FT.
r
10' IS 8' SALES
AREA FRAME
LF
GAR
BACKIAIRAP
BLF SI4V
VEST. 110
IIRROR
10' r 8' SALES
AREA FRAME
122 SO. F.
FIXED
HT -M
ITSM
WOMERS
SV7Eils
30a11
1,079 SO. FT.
WOMENS
i
004 SQ. FT.
4LF
1-1GR,
STG,
EArm- AiA
S1-9 Si
300
L
11:702,02604*020Z
TT)
10' x 8' SALES
AREA FRAME
R IC102
¶T L.
SW/. 14
SEC.
D—c)
1-1 Tr.
51-1V. 14
SEC.
RECESSED PUF'LEX
FLOOR RECEPTICAL, SEE
E L. ECT R ICA L DRAW NC/
IRROR ;31
10' .tt 8' ENTRY
VESTIBULE FRAM
30x4
NOV.
51-G. DECK
ABOVE
44t,J1.1.ETIN BP
I
101
272 SO. FT.
1.5PET
MEZZANINE
&)IRROR. 051
IRROR
TEL. PHONE
[MIRROR gl
BEV
rf.ACA
10" SALES
AEAAME
VST. 105
125 SO. FT.
S
1..1 1,, .0.
S2-7
Qc
CAS 1NRAP
?ENS
108
942 SQ. FT.
103
S24
1,0(1S SQ. FT,
30c1J
EOL
S2
ACKSAP
. _
ELEC.
ROOM
10' 3' SALES
AREA FRAME
10' 8' SALES
AREA FRAME
MIRRO
MflROR
DEAD SPACE
58 SQ. FT.
IRROR
ST. 11
rRtVi7E
3'.1AGE3, S1GI'JAGE
tin- nor) FAO
REFER TO r....Er 411.1
Roo:. 11
lI0OiI 11
no0.1 11
1,523 50. FT.
DN TO
MAIN FLOOR
RTTfl1G 103
J,
101 SO. FT.
MEZZANIN
S2-1
30cd
34
FIRE ALARM SYSTEM PLAN
FLAG NOTES:
FIELD LOCATE RELAY MODULE FOR
BACKGROUND MUSIC INTERFACE.
DUCT DETECTOR, MONITOR MODULE & TEST
SWITCH LOCATIONS TO BE FIELD VERIFIED BY
MECHANICAL, ELECTRICAL AND FIRE ALARM
CONTRACTORS.
DOORS FOR DRESSING ROOMS ARE HALF SIZE
HEIGHT DOORS ONLY.
N
N
cO
SO., SEATTLE, WASHINGTON
FAX (206) 628-4990
TEL. (206) 622-6545
I \ L_ /Th—J 1— / I I— V I •.1 I \ I I s.—J
NO DATE DESCRIPTION REV. BY:
0
a
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
t HID 1.1111,41DCD. 0 ,17___ 1 .
...\
SHOP DRAWINGS
04/08/14
'SCALE: 3/ 1 6-= 1 "0". `
DRAWN BY:
D. GARCIA
DESIGNED BY:
T. QUAALE
DATE: 04/08/14
BACKROUND PLAN PROVIDED BY:
t HID 1.1111,41DCD. 0 ,17___ 1 .
r SHEET
FA -03
Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
MAKE SEAMLESS
TRANSITION TO
EXISTING CEILING
RETAINER STRAP VI•IERE REQUIRED
IN SEISMIC AREAS
TOP BEAM/ C-CLANP
WITH SET SCREW
3/8' ALL THREAD ROD
PIPE SWIVEL RING
STEEL MIST/TRUSS
HANGER DETAIL
NTS
G.C. TO REINSTALL EXISTING
EXIT LIGHTS AFTER- PHASE •i
CONSTRUCTION
NEW LOCATION OF EXISTIBNG
RECESSED CAN LIGHT. EXTEND
EXISTING CIRCUIT TO NEW
LCOATION. REFER TO SECTION
FlexHead Sprinkler Drop ..
Corrugated stainless steel hose with stainless steel braid
available In 7, 3',4',5' & 6' legnths .
Multi -Port Bracket
Adjustable Hub
o Without Comments
o As Noted in Red
Per The Attached Letter
These plans have been reviewed by The Tukwila. Fire
Prevention Bureau for conformance with current City.
standards. Acceptance is subject to errors and
omissions which do not authorize violations of adopted::.
standards and ordinances. The responsibility for the
adequacy of design rests totally with the designer.
Additions, deletions or revisions to these drawings after:
this date will void this acceptance and will require a'
resubmittal of revised drawings for subsequent approval..
Final acceptance is subjecttofield test and inspection by
The Tukwila Fire Prevention Bureau.
Date: 3-1 61--1 J gy
•
- Elexiieed'bomrnerciai Ceiling Unit
T -Bar Celli igInstallation •
Model #2024,2036,2048,2060,2072
G.C. TO REINSTALL EXISTING
EXIT LIGHTS AFTER PHASE 1
CONSTRUCTION
TUKW�WILA FIRE DEPARTMENT
Plea call 206.575=4407 and
give this Fire Permit No*
and exact addles for shut-
down or restorttion api 'vol.
�I
MAKE SEAMLESS
TRANSITION TO
EXISTING. CEILING --\;
•
•1• •,J :.• r•=' .)••
L
NEW LOCATION OF. EXISTING TRACK
LIGHTING. REFER TO SECTION.
EXTEND EXISTING CIRCUIT TO NEW
LOCATION AND RECONNECT
NEW . CEILING IN RECESSED
ENTRY.
• 6 — Replace existing pendent with Reliable Model G5-56 Concealed Pendent 165° 1/2 x 1/2
(cut for new ceiling height using a Flexhead)
O 6 — Add Globe GL566IStandard Response Upright 155° 1/2 x 1/2
REFLECTED CEILING PLAN
' Z.
Abercrombie & Fitch
SPACE #E-556
LEVEL 1 OF 1
NEW LOCATION OF EXISTING TRACK -
LIGHTING. REFER TO SECTION.
EXTEND EXISTING CIRCUIT TO NEW
LOCATION AND RECONNECT
j.
• WASHINGTON STATE
FCERTIFICATE OF COMPETENCY "r
IRE PROTECTION SPRINKLER SYSTEMS. . •
CG Level 3
John J. Abe!
Protection, Inc.
9760-0591•
Crown Fire
CR FP
r••
°■
X. Signature - •
Nuarlse mm mm
s•.
r. -
r
A
•
CROWN
FIRE PROTECTION.•'.'
INCORPORATED
P.O. BOX 12113
HILL CREEK, WASHINGTON 98082-0113
PH. (425)481-7669
•
Abercrombie & Fitch
Southcenter Mall
661 Southcenter Mall
Space 556
Tukwila, WA 98188
FAIR.::.:
MAR 18.'2014
TWIN. LA FIRE"
'27975 ,,,ZO3—
DATE:
DRAWN:
v:
SCALE:
fly►