HomeMy WebLinkAboutPP - 670 SOUTHCENTER MALL - ANN TAYLOR LOFT - PERMITS AND PLANS670 SOUTHCENTER MALL ASSOCIATED PERMITS 16-F-027 16-F-015 12-F-179 12-F-039 16-S-032 16-S-007 16-S-003 4.41Mci J 1� SITE LOCATION Site Address: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. _ \ 5 7 0 **PLEASE PRINT** X355 S. 1z., " pi King Co. Assessor's Tax No.: Suite Number: Floor: Tenant Name: %() V V S — S 0 e TI New Tenant? ❑ - Yes IFf..„No Property Owner's Name: J p b C Y — o �i-- f�'C A s Mailing Address: J 3 7 S, 1 Z J ti k to 't ' Ar City State Zip CONTACT PERSON -if there are questions about the submittal. Name: 2 0 .' U J Day Telephone: Z- O b 3 T 0 0 1 Company Name: Az_C e� Q p Mailing Address: ?- h- l� e LAJC›-v (01 — d 6 S _ City State Zip E-mail Address: C� V CO" t C- e— (14. t e"E- .0 d ►`t Fax Number: L Z j 5 6 7 6 6% 2 ‘c e - 3 1 T Valuation of Project (contractor's bid price): $ r7 , 3 7 a-1- New e V t c e, Scope of Work (please provide detailed information): it) 9 P V t C P_C T J PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNS' ORA - i ° ED AGENT: Signature: Print Name: Plan Permit App.doc Day Telephone: Date: S l a ('a crs5 vt)3 5/14/10 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 67D 5(0/He/pied- ),7a1/ Suite Number: , Floor: Tenant Name: die Uver. Property Owner's Name: \)j T \eA ?'rCS Mailing ?. Ni(Nyyr'r. Address: CONTACT PERSON -if there are questions about the submittal. Name: Company Name: New Tenant? ❑ - Yes ❑ - No City State Zip Day Telephone: Cohn Mailing' Address: PO SOX ale )97//1 WA- f ti & city E-mail Address: ��S'CQ. Pr _�NYtCQ %�'] Fax Number: 9Z6470-7,6 t� • Total number of new/relocated devices or sprinkler heads: 1714i Valuation of Project (contractor's bid price): $ 8� D .' Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. _ I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING S - ER OR AUT . ORIZED AGENT: Signature: Print Name: Plan Permit App.doc 1/2/13 Date: / 6 ` a Day Telephone: 4'2 %'l7lyi2 9 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470130 Site Address. 21 Southcenter Mall, Space 670 Tukwila, WA 98188 Suite Number: Floor: Tenant Name: Eddie Bauer New Tenant? - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept Mailing Address: same as site address CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 City State Zip E-mail Address: kveliz guardiansecurity.com City State Zip Fax Number: 206.374.2852 Total number of new/relocated devices or sprinkler heads: 7 Valuation of Project (contractor's bid price): $ 5,500. Scope of Work (please provide detailed information): Add 7 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING I WNER OR A THORIZED AGENT: Signature: JQ Date: �71Z1(Ci° Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION 9202470130 King Co. Assessor's Tax No.: Site Address: 6$0 Southcenter Mall Blvd, Tukwila, WA 98188 Suite Number: Floor: Tenant Name: Eddie Bauer Store Property Owner's Name: Westfield Shopping Center New Tenant? J - Yes 1:1- No Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206-349-5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City State Zip E-mail Address: Fax Number: 205.374.2852 Total number of new/relocated devices or sprinkler heads: 20 Valuation of Project (contractor's bid price): $ 6000 Scope of Work (please provide detailed information): Add 20 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING . . N R OR AUTHORIZED AGENT: Signature: Date.GZ Print Name: Karina Veliz 206.349.5889 Day Telephone: Plan Permit App.doc 1/2/13 TFD FP Form 8 Otrit"44 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: (ID Sour/1621RA 13 I Vd Tenant Name: Property Owner's Name: Mailing Address: CONTACT PERSON -if there are questions about the submittal. King Co. Assessor's Tax No.:o. Suite Number: G /2, Floor: New Tenant? ❑ - Yes n_ No rrang Name: Nirfa Company Name: City State Zip Day Telephone: 4425:— t//— 7K 4 9 'V0tu1 Fir prOk6eAlThl MailingAddress: l C)S /c7113, (U) arUX tJl 9gOtZ E-mail Address: ) I S i Ca (v O "VP 7( City/Fax Number: 1.4,25--1.4,25--y� 9r Total number of new/relocated�devices or sprinkler heads: /3d d 5 Valuation of Project (contractor's bid price): $ i 00 .0/ Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Plan Permit App.doc Thenv Date: 27//Wgi__ Day Telephone: 1/25' 7U �'` 7 &el 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Eddie Bauer 670 Southcenter Mall Permit No.: 16-S-007 Date: January 15, 2016 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Eddie Bauer 670 Southcenter BI Permit No.: 16-S-032 Date: February 26, 2016 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. Jan 11 16 04:46p Crown Fire Protection FAX TRANSMITTAL 4254818695 p.1 Fax No. CROWN FIRE PROTECTION, INC. ®= ECM 1.11.16 Fire Prevention Bureau Tukwila Fire Department i Al Demo Permit Number of Pages (Including Cover) ❑ Urgent H For Review 1 206.575.4439 'LA F7.7,7 CZPAR7772:717 :. ,1: Z G -:75-4:e.,07 'r ctoivn or natartIVOnCppinOvelo 0 Please Comment 0 Please Reply Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comments We need a demo permit to remove (4) heads that are in the way of the new wall at the Eddie Bauer Landlord Work Project — 670 Southcenter Mall. The building permit 4 is D15-0265. Please let us know if you have any questions. Thanks CErRT,F�OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS q P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425. 481.8695 'TUKWILA FIRE DEPARTMENT Ram call 206-575407 and gsvQ this Fire Permit Pio. /(e -F-01.7 and exp addmss for 2hut- down Cly ' f'i l prpmv LL EDDIE BAUER STOKE T.I. FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL WIRIN G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FI E ALAR VI SYSTEM PLAN SHEET INDEX Without Comments As Nosed in Re0 Per The Attached Letter plans liafe b_._!n reviewed by The Tukwila Fire >,r�ion Bureai.i foo .:onformance with current City �!"ds. Accept i:' • - .'i ,;tioject Yo errors and which cr' :.. '• ht ftt nrize vi0lations of adopted r .3iC1S �al�a rat t3:, i: >, Tne responsibility for the y cY de& Ot lly with the designer. '1elet,orl;-, to these drawings after is ,f,,ta Voici i ::-.1ccaotance and will require a rr�.,T ,rnitta! ,;r nevi e(i ,:z,• : -a,nrs rnr subsequent approval. Firal acceptance I;., sub,ct tleld test and Inspection by 11^de Tukwila Fire PrevF:rition B eau. Date: )-_j a-- I Co By: NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be pi-cs .ted to the Inspector ps r to commencement of ,acs:-l� nce Testing of any r it and Detection ys. • Failure of test wiii in a Re -inspection termination of the to WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA UNE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPUFPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPUFPLR RED (JACKET) REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 2 2 3 6 7 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER Ex POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING DUCT DETECTOR D AD2-P W/ SIEMENS HFP-1 1 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX ' VERIFY IN FIELD ai FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND • 5 NORDSTROM 3 LEVELS V 1/ 171,275sf macy 4 LEVELS 250,4070 EDDIE BAUER STORE T.I. #660 FUMC • 1-1 ti7Et}I, PE aROM OtVAILAR PEW { ,121.551 3 k GOLD Lvi;� 1T s n I wr_4Lv RED P�=t. E:Unt, ueP,P, fKO ERS �,� 1, ELLR2 1 JCPenney L£4EL 2 E,466st Q PAID �i, FF9 -3 211M,/// TUKWILA FIRE 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE M 0 N 0 2 CCCCC b) w O T 00<z 1-QOt- H CCW w = In CD =¢ CO U) Q 0 LL E- 0 w W (1) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/03/16 BACKROUND PLAN PROVIDED BY: \ OB NUMBER:15148-1 j WIRE DESIGNATION GENERAL NOTES SITE PLAN c 42/ Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 } THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE; SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6011Z DEDICATED EMERGENCY N015 FOR ADDITIONAL SPECIFICATIONS SFE PRODUCT DOCUUt:NTA110N. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VOC ME MN TO NEXT ADDRESSABLE f+ DEVICE STOP IF LAST DEVICE - FROM XLS CONTROL PANEL + IR PREVIOUS ADDRESSABLE DEVICE - 0 FROM PREVIOUS (+) ADDRESSABLE > DEVICE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 5 m 0 0 P1 m 0 5 m m r N o 0 0 FITO C 0 F, m (-)(-) (+)(+) EPEE (+) 0 WIRE DESIGNATION, NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIED) #18 FPLIFPLR RED(JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 3010C FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O T. ;I ° © © -L J4 HTRI—R Ilg cI J O O ° GROUND DRY CONTACTS TO VAV --..>. FAN SHUTDOWN PROVIDED BY MECH/ELEC. (+)>TO NEXT DEVICE OR (-) STOP IF LAST DEVICE DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FLED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL 'I _I HTRI—R INPUT INPUT TROUBLE NCI NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NO C NO + - + - + - + - + - 3.6k EOL C -CABLE SPARE SPARE j SPARE C -CABLE (—) + v HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +322'' F (0' C TO 0(1 F (38j C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —� –� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE • DATA IN (-) >--- DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING /- HORN STROBE STROBE ONLY DROP CEILING MOUNTING • HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR "- SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 z 0 UJ w Q Lu J W REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE M 0 N 0 2 CCCCC ■ I- o W O Orn O 20 I— < cd t- (/) w 0 CC W WT w co0� IT -44c ac� m !C (q _ CC c0 0 W I (6 w 0 c� z F- O 0 z z J U 4-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/03/16 BACKROUND PLAN PROVIDED BY: JOB NUMBER:15148-1} I SHEET FA -02 `Power A FIRE ALARM BOOS TER POWER Project: EDDIE BAUER -STORE T.1. SUPPLY SUPPLY (mA) BATTERY Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Panel: 1 EXISTING PAD -3 BOOSTER POWER Date: ; February 3, 2016 Qty Mod ule/DeviceStandbyTotal Module 1 30 30 0 30 30 0 TOTAL FIRE ALARM POWER SUPPLY 30 30 .I B':,Auxiliary Device Current 0 0 C ©75cd -CW 95cd ; Notification Appliance Load (Max_ Total I mA) 0 5772 _ t __ i a@15cd -CW + 15cd D E F G H I J K Total(A)= 30Total(B)= 5802 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 30 5802 Total current ratings converted to amperes (line D x .001) 0.03 5.802 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 .M,et. .Y, yry3"S .,�„ v ,.', `rY m✓.. "', �� - k r; 'M',xv °1tf ''.'"' dp r4::', y ^,• i; a',:';,<: �: ;, ,N"a;.�. -�r n r,�\";:-" � .jk ,. ?'�. (�,^ t �.��, � A ° .I m, �l,.,: �'.,� �,,,. � ,� M .� ,,,, S, � � �.a - la \� t Y �.r'ry � � E'. �,. � v „� s ���1, .,,� ,.,,m x „"�,. '., _ ,� w�,,r, tl „vk rv, v,i " +, ”, . 7,w',.P :...o , n n t ., w^ . , rt � r ... � M"W, � Cm., � ,.. ,r;'C. °I, �u.,�,^, 1".f.. 1 h„ �„� .. ..,, .A a,l r' a. : rv,yWv .., "�,, �,� :r !^I ,^*:��. w �°, „.,. r ,” •,, - Multiply lines E and F . Total Standby AH 0.72 I' b''. r u, :i"','+1,4�rw + '.W,;,x. , q u�, k ,A +"I�t,w r >,,., • o �^' P$: a. �. Mr .�„M ��, .,', �. X �,;, � Alarm sounding period in hours (5 mins+ .0833 hours) _.."..:'. Mr\''�', � *, r ��n �„y�'I 0.0833 Multiply lines E and H Total Alarm AH ; TOTAL Wire Resistance (R)( Device Load, Amps (I) u. Drop�(E i _ � _ 0.4833066 Add lines G and I Total Standby and Alarm AH 1.2033066 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 1.44396792 _ _ __, 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 PROJECT: EDDIE Notification Appii nce Circuit Detail 2.58 5772.00 BAUER - STORE T.I. POWE SUPPLY Wire Resistance CURRENT TOTAL= Panel: ; EXISTING PAD -3 BOOSTER Date: February 3, 2016 ' r a k""fi.,,r.w,�„ uv %k9V'#'k�m arY I�mjnww\, .'�'��°,, '^.�id a •a l 2 ZH-MC-CW 3 ZI*41#C 1 ZH-MC-CW C ZR•MC-W _ 2174. -MC DEVICES 13 Total Total _____ ValtageDrop4(E) L Voltage i m,uaa,";'( :M"* Nx, rmmm'ni„ J k'I ;. i r�.'' m" m,f�r ,v �d (f�ly. r-�(ta�, +`�''�'t 1 C r m a©15cd CW 30cd 87 131 222: 292 , �� 174; 393 � ' .I o cul N6 qq�N k r4, ©75cd -CW 95cd 222; 0 0` 483 _, . ._ i 272 ` 14 �_____, ��E�� _ t __ a@15cd -CW + 15cd 64 69 mA= _ _�_i.__,. .. . ' TOTAL Wire Resistance (R)(W Device Load,' Amps (1} +.. +rk, 278 22.18' 1272 2) * (Rift) (Total_Cc Load) 43 1.43 1.27 . 1.82 1.82 �__ ,_(E= I * R) 24 E) 22.18 .M,et. .Y, yry3"S .,�„ v ,.', `rY m✓.. "', �� - k r; 'M',xv °1tf ''.'"' dp r4::', y ^,• i; a',:';,<: �: ;, ,N"a;.�. -�r n r,�\";:-" � .jk ,. ?'�. (�,^ t �.��, � A ° .I m, �l,.,: �'.,� �,,,. � ,� M .� ,,,, S, � � �.a - la \� t Y �.r'ry � � E'. �,. � v „� s ���1, .,,� ,.,,m x „"�,. '., _ ,� w�,,r, tl „vk rv, v,i " +, ”, . 7,w',.P :...o , n n t ., w^ . , rt � r ... � M"W, � Cm., � ,.. ,r;'C. °I, �u.,�,^, 1".f.. 1 h„ �„� .. ..,, .A a,l r' a. : rv,yWv .., "�,, �,� :r !^I ,^*:��. w �°, „.,. r ,” •,, - •- {, 1 :('.i f.. .., �.,""' ; ,. wfi d 3Yi ..,." nt^�,,,, , .I �� . � I. � � � i. .: Yvu � "rv' k ., .� `M,, .,,' ti,i,� n .k ', , v . � " a ,u. d.. ,. „i .. wv yr ��'k ,,., �,: d. �W„ � i'. ,, a I' b''. r u, :i"','+1,4�rw + '.W,;,x. , q u�, k ,A +"I�t,w r >,,., • o �^' P$: a. �. Mr .�„M ��, .,', �. X �,;, � „M,,,, ,p„” .o ,, 441" _.."..:'. Mr\''�', � *, r ��n �„y�'I � „�!� � ' n,lt., �,, ,� � Y !�•r 'i� 3',,'.:�k", DEVICES FULL LOAD ; TOTAL Wire Resistance (R)( Device Load, Amps (I) u. Drop�(E i _ � _ �,- mA=; 1500; 14 24.00, (W Rift) (Total Cct Load) (E= I * R) E) 1500 ;Total K J Total _ _ __, , 0 00 '1.50 .�---�-_�- 0.00 ':Voltage OL Voltage24 z,..,,w 'Cq .,•o;Ya"IFr' ��k;'"n ° ,n^^'^"' �!�!�. .�::'� ^.�;w,t ,11 r "fix .. ,.",r.' r. �, !S", .�q� G" r ",,;��,� -. ,. .,. .,��'. ;..,r ,� '!,A..,. ,a,', f ".d.;,, .,IMS r„. 1 �:,� „„�r7 ,.»vM Y.. "„w”, � ���.,v____� 24.00 . # Md^�'.. n"�' �< z �? as >+;",+pr ., %jdw � a",m'''Ih"✓,, ,, .::' ° +,';�t aa^� ; �," • M A 'r�,Y 5, P.,� �,t{c ,',,', a` +�9 ,,k{ ,^a ,;,,., r. '.p�\ m�, 4 rw+ • ` .µ.. rr'�Xff G G" $p', .. �, �1.;. ', *,; ”'\�" .�'• �1� %:; .���, tl � M,� ,' �,�„ �, �: ,. II ,.;„,: v. ��,, ” �Y',r, 4^... .V 1 •���,, ,, f i,., v, m :r�� "�„r;. a ,. w„vR” . ' r� ,; , �'" .. .,•,,,f,M 6r,r ,,, { ,In; 'r.. ... 'd^y4, „ryf; ,~•'t �r a ,,,',, ,„?” i, ,Y, .,. rR+' ,,X";r rrby w.” e,v. -15001 14 �.__ _�.. ,,�, � ti � w } .�,,: �,PJ, Rx Nr d,+ - K M,d,& Y\ 4 ,\ro Jr 0 Y. '7,, i `,: ..�, �„ �- n f� @r���,I rt,d fio�„ k'i ."{„�i "i3'' .a`,. a 24.00; a,,rk.��. e,r '+.�, ., w” , c , c, Cu' �6tM# r. ^'„.,.. 1p +,�\y r bAi'ky,,, 1500 .Q0 1 60 0.00 DEVICESFULL LOAD I TOTAL mA= Total Total `Voltage - .. �L Vollge . ',.��"p.. d ",„ i,,�0.M,; �+'�,.� rfi ;a.: m,.wm,YM „Ir �n"m,'����, G #�',:�tlIIIIV 11 MB";�k Wire Resistance (R) Device Load, Amps (I) (Total Cct Load) { _. _____�. _ _ ._..��__� (E* 24 - E) Drop { E) .fr 24.00 Irtr ,dr;,ir a y Mi ,Y ° ,1. .; �}hyr��T �b'� N, Nm6J �m,,,w, p�M1l 'aha*;�.�a (,. �11 `k M ',;i �: r.- +yy' '��, ^,,, :.'M Wim' �,�)r a �:i,'�Ib�� ➢Po ° G�.il ;'�S)r, � "�:'. t d rM, ',; �.'. d'i "",. -� %a lypq�.' ., I,r . r(�'1 . :, MI a','w;. .3 rI ISOm' .. Jl�ro x �i"' r '"'�, ty rv4,,,, rr��bb S „! „ r ..: r r9 '�M#k��,,��� � �"y� K.�,>P e i V rW(,�'il�� �a Iy�,i Y. 0 :yC Y Ai ,. ,,,$�tlu'G w m d'rJ Yea>'?'4,, .,l\„M'i+:-,� '4'^�,a V'MY °'. "m,' r MI i„d lkdA '� '�$f `I �'j�'r4Y't'd' h... rlr I P .y �.,'���,Y ✓+�, ';1^, ,:w.e'"fi 41" = r'r;!',^M' '} x^. ,,. ■■ 4 t ..N �6,mM \vUTw^ ¢ i'yJe f','Vx'i,.' iiv'4u�i[i`PvY""Ydlf 1500. 14 24.00! (W 2 ) * (Rift) �* _. ....., (Total Cct Load) _ _ �_._. (EI*R).._ - ° 24 - Gpr: ,r. xrr + . _._. ,.i aw. /��� �""ti•�I;v,. i�•aF3dt �.'�'. x4dz 1500 DEVICES FULL LOAD TOTAL Total Wire Resistance (R) Total Device Load, Amps (I) mA= 0.00 1 50 Voltage Drop (E) .-.. EOL Voltage' 0.00 24.00 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS SYSTEM CALCULATIONS TO NEAREST EXISTING POWER SUPPLY (EXISTING BACK -OF - THE -HOUSE J -BOX) TO NEAREST EXISTING ,, • DATA LOOP S4-1 S4-2 30cd 15cd S4-3 15cd S4-5 15cd HT -R S4-6 15cd S4-7 15cd S4-8 15cd • S4-9 15cd S4-10 15cd S4-11 75cd S4-12 30cd S4-13 30cd FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. EOL S4 DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 0 ac 0 W z W Z co J W o J C'3 CC 273) � z o O Q2o C j w� o ww= W cn0� Q CO m Qlig 0 cc co CDo IJ 0 W F— >— Cl) 2 CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/03/ 16 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM 1.OB NUMBER:15148-1i % TO EXISTING BACK -OF -THE HOUSE JUNCTION BOX I I 7>- u, CU Q p, CU SL/ WA I I VALJ STCCL ROC A Ii n SLAT WAIL HS 72" r L WS 48" S4-2 15cd "1 L (f.) BULLETiN BOARD HALLWAY S4-4 1 5cd s—c, //, .4/ /477-77 S4-3 1 5cd S4-8 15c H.C. FIRM 1 04 IS V Wife Aard Agar Nir Arore/ I I-IHM G,41-6 1 5cd ✓ Agsprorhy ✓ A ....111 FTRM 15d 011 LOiSRii COAT, HANM BULLETIN BOARD BULLETIN BOARD 11 • ACCESSORY S4-10 15cd ------ POSi S W FETAL 01 IS 561W DISPLAY TABLE I • S4-12 30cd S4-9 1 5cd FIRM 03 HALLWAY .r ACCESSOR I 6 : I: I i-Lti I 66IN DISPLAY TABLE I a' CU 1W) POS 14 - Err - 66161 DISPLAY TABLE t • FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. OUTERWEAR GEAR M FIRE ALARM SYSTEM PLAN • • .••• • • • • • • I • 661W DISPLAY TABLE I a. 11°_i CEAR POLE S4-13 6EIN DiSPLAY TABLE I 11 \ i I I 1 I . \ • • s - ...t , j ----- ,_. II 56IN DISPLAY Tv.."-ILE 14 6.5 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m c: DESCRIPTION SHOP DRAWINGS DATE (0 to 0 C•I 0 2 <<<<< z cog WO'- --JO) OcD ° <z 20 I— < cri— U) = M W CD pr.c,2 2 ft: co 5 tig LLI LL. CO ‘CALE: 3/16" =1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/03/16 BACKROUND PLAN PROVIDED BY: 1.13B NUMBER: 151 SHEET ( \ FA -04 NO r A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to comme;-tcern of :acceptance Testingci- any Fire Alarm and D+;.ectic i Systems. Failure of test tt ill result in a Re-inspecdan Fee and termination of the testing I FIRE ALARM SYSTEM ADDITION TjJKWILA, WASHINGTON SHEET NUMBER SHEET TITLE FA -01 SYSTEM I \ FO MATION FA -02 TYPICAL WHI\G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SI\GLE LINE DIAGRAM FA -04 FRE ALA vl SYSTEv1 PLAN SHEET INDEX 3 Without Comments 0 As Noted in Rett 0 Per The Attached Letter These plans !}eery 1 eviewed by The Tukwila Fire C'(,: ention Bur ezu} .:ynforinance with current City '.;dards. Acce,oa:: ti.:,ubject' to errors and :missions which cin >;c: .3utrorize violations of adopted ?rdards aivr o,I-,,,;1_1.:'.:ts. The respons:hll!cy for the adequacy of dc;.sinn .':tally with the dc;s gner, to these drawings after this date will , ,,d _.::.:�cceotano and will require a resubmittal or , t] ; i =er.° subsequent approval. Final acceptance is suvfe�_ ,o Odd test and Inspection by The Tukwila Fire Prevention Sureau. Date: 1—?•61") So By: sl and z lit, No i. .F- of s' aY,B add ess for shut - flown or restoration approval. l. D U LE AND C O\ D U IT FILL C HAAT SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11 ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12 ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13 ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 1 ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15 PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16 WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17 ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19 THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 22. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 7 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER EX POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3—ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO—ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING ®D DUCT DETECTOR AD2—P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1—GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI—R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD DI FIRE ALARM HORN STROBE ZH—MC—CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR—MC—CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A -N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 171,275sf macys 4 LEVELS 250,407sf 00—� .�-. 6�fie3iG FC IIOX SHOP 3 050 dux MSC Caw x Rets= 2 TZ, RtRE RLSr. a':r=_4a uu s CLASSs Otte I I C. 2I r EDDIE BAUER #670 PAID JAN 19 2016 TUKWILA FIRE rt) 176 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C D P S S' V V I STROBE SYNC DATA LINE -ADDRESSABLE LOOP DEVICE POWER - 24VDC STROBE CIRCUIT - FEED STROBE CIRCUIT - RETURN SPEAKER CIRCUIT - FEED SPEAKER CIRCUIT - RETURN REMOTE INDICATION LIGHT TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) TWO #16 FPL/FPLR RED (JACKET) TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR #14 FPL/FPLR RED (JACKET) TWISTED PAIR #14 FPUFPLR RED (JACKET) TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11 ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12 ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13 ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 1 ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15 PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16 WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17 ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19 THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 22. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 7 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER EX POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3—ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO—ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING ®D DUCT DETECTOR AD2—P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1—GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI—R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD DI FIRE ALARM HORN STROBE ZH—MC—CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR—MC—CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A -N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 171,275sf macys 4 LEVELS 250,407sf 00—� .�-. 6�fie3iG FC IIOX SHOP 3 050 dux MSC Caw x Rets= 2 TZ, RtRE RLSr. a':r=_4a uu s CLASSs Otte I I C. 2I r EDDIE BAUER #670 PAID JAN 19 2016 TUKWILA FIRE rt) 176 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE t 0 Z coo O -� IZ i= Q °) w 2 < Q 2 co w W= W (n � 0CC'5-- 0wog Wwo cc N I: I— Z 0 �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 14/ 1 6 BACKROUND PLAN PROVIDED BY: SOB NUMBER:14381-1i WIRE DESIGNATION GENERAL NOTES SITE PLAN c� Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING 01 AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6011Z �j DEDICATED EMERGENCY 111 NOTE FOR ADODIONAL SPEC61CA1fcNS SEE PRGOUCT DOO11liNM110N. INTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC tgglim TO NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE MOI XLS CDNTRO. PANEL a+ O2 PREVIOUS ADDRESSABLE DEVICE 0 GRCOND 0 HTRI—R 0 0' 0 0 NOTE: FORADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) 00 00 a PAD -3 00 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 0 0 0 0 0 0 0 3.6k EOL (-) (+) (-) (+) 2 SPARE SPARE SPARE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) C WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIRWITH SHIELD #18 FPUFPIR RED (JACKET) *CONTACT RATDIGS: 4.0A 0 125VAC 4.OA 0 30%VC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. GROUND (-) 4 J HTRI—R o 0 O 0 0 5 72)' (+)> TO NEXT DEVICE OR STOP IF LAST DEVICE (-) _.> DRY CONTACTS TO VAV — FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL • POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY 0 HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TYPICAL TO NEXT DEVICE OR END OF LINE WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN TEMPERA RE: +32' F (0' C) TO 100 F (38' C) HUMIDITY: U-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -* FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WM DUCT HOUSINGS AD -11P OR AD-11XPR DATA IN ( ) >- DATA IN (+) > REAR VIEW DB -11 STANDARD SMOKE DETECTOR BASE (-) (+) SMOKE DETECTOR WIRING DETAIL < 0 0 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX 11111w— JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT I 0 0 =Vol= TO NEXT DEVICE 00 CADDY BAR SMOKE/HEAT DETECTOR \ SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 0 z<aaa< z 0 -� o CC o Qz W 8¢ p QW �Z 00 W LLI LUQ 0 cc_� Q<0 W W o to LL I— -J SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 14/ 16 BACKROUND PLAN PROVIDED BY: \.OB NUMBER:14381-L) SHEET FA -02 Security Systems, Inc. All Rights Reserved J _ FIRE ALARM BOOSTER POWER SdPPLY SUPPLY BATTERY CALCULATION Alarm (mA) _ 01 *0 « 0 _ a fl Project:: EDDIE BAUER " & �V:Ntu� nem» ...�.,.,.aj n� . 'y _ Panel:. EXISTING PAD -3 BOOSTER Date: January 14, 2016 Module/Device POWER Qty Standby (mA) .r .� ._T,_.� _._ _. ZH-MC-CW @ 0cd 131 171I -MC -CW 75cdn . _.� x.222 . �_�,_._... til-IAC-CW..r@95cd .292 MC W ©15cd ; 641 Total Standby (mA) Total Alarm (mA) Power Module 1 • -30 30 30 30 A TOTAL FIRE ALARM POWER SUPPLY d .� � ,ar 30 30 B ! } y Po; ' { P,r, d @ 1 ;Auxiliary Device Current t 0 0 q } 0 C j Notification Appliance Load (Max. Total / mA) . 4 - 0 4403 1 ' 9 I _I_Tota!�A)= CALCU'_ATION } ____ -___- .._-____ 3O i Total(B)= 4433 __-......_.__ _._.-_..,,_...__ _______-._-------..____._._. 14 . D E F G Total current ratings of all devices in system (line A + line,E + line C) 30 4433 Total current ratings converted to amperes (line D x .001) 0.03 4.433 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 ELVolti e g Multiply lines E and F �. � Total Standby AH 0.72 ;. ... • ,: tw'T"IWW ...:.-:,a . �: ���,�,� ;°I, r,!i,iµv �� .ifl,A ,, ,��::',�„ p(� � 11ry„ _ ... r...,...,.,.<... ....ac. 1.... __.,.” w . ._ _ 1 H Alarm sounding period in hours (5 mins+ .0833 hours) �Ir; ,,., .: . t4W ',: ,yF r1 ,? \ w r ,m'' u„ ,,,,y::r 5 ,:,�1 :�'ui a ^ '''.`•„:,.., � � r,N .} _ t yn p' a � d `z a 'r< b�5';d V4 <W �$t'.r ek,',d,:Ar G ,, .R ���,+rr,:��'�y .,._....wac... 0.0833 I K Multiply lines E and H Total Alarm AH <i.J.�,Y�. .aa�i ' ' - - 1. <..wu.a...«rr... 71H -MC -CW @15cd 87; 0.3692689 Add lines G and I Total 4ta.ndby and Alarm AH 1.0892689 YZH-MC-CW 30cci. .131 ZH-MC-CW @75cd22_2; Multiply line J by 1.2 (20% extra insurance to meet desirn1 performance) 1.30712268 876 0 12-V DC BATTERY SIZE RECOMMENDE' (AMPERE -HOUR) 7 DEVICES Notification Appliance Circuit Detail PROJECT: EDDIE BAUER , Resistance TOTAL= 2.58 4403.00 0 Panel: EXISTING PAD -3 BOOSTER POWER SUPPLY ;Wire Date: 'January 1412016 CURRENT )...' .._, . -_•,- ::, 't_;, . �'...•......P«,r�k.N-'p,.f.� ..:,,.0 ....,.,, rll�^ v aY..r-.--..1.,ZH-MC-CW -- -; ____ �.-.1714, DEVICES _ _ --- _ 4141• 'uf.. d w^C.I""ro:::d,."....eI..� m. , ' k'M1 M1 rni.. L @l5cd 87'.. _ 01 *0 « 0 _ a fl � " & �V:Ntu� nem» ...�.,.,.aj n� . 'y _ 4 , c w� Ti ...uu.,...x>•....,r,...-.w...,....—_ f _" . j 1500 0.00 1.50 0,00 G'% _ .. ,.».,..�.._,�» -_.. w _._ _ - .�. _ 24.00 .r .� ._T,_.� _._ _. ZH-MC-CW @ 0cd 131 171I -MC -CW 75cdn . _.� x.222 . �_�,_._... til-IAC-CW..r@95cd .292 MC W ©15cd ; 641 , ._ . �._ �4 .. - 14 Zit -MC -CW ;15cd 69 ;0 ; TOTAL mA= i- 1500; ;Total Wire Resistance (R) �,� _ �;T (WL*2)*(R/ft) Notal ((E_ Total Device Load, Amps (I) Voltage Drop (E) w. R_... __ -__-._ ._..,_.._.,.... , .A EOL Voltage Cct Load) I. * R) _..... �4 d .� � ,ar 1 4 Y@'",.B+,4e,$1 t7 rp h @�,:, �:'.}, @iJY9; @ t".�„d x $ i y Po; ' { P,r, d @ 1 :•a ;�: ZH-MC-CW @15cd 87:y 0 _ _ DEVICES ZH-MVIC-CW @30cd 131 1711 -MC -CW @75cd 222; fl 0; ZZZZ-MC-C1PIW-9cd 292:: iZR-MC-_W_@15cd 64 .. -MC-CW @l5cdt• — 69 ,0 ; TOTAL mA=1 1500 fl 14 . 24.00 (WL*2,)*M. j Notal Cct Load) _ _ _ : ;(E= 1 * R) 1500 0.00 1.50 0.00 Total Wire Resistance (R ) j Total Device Load, Amps (I) . jV oltage Drop (E) ; i . ELVolti e g �. � � `■ �+ i/W, ;. ... • ,: tw'T"IWW ...:.-:,a . �: ���,�,� ;°I, r,!i,iµv �� .ifl,A ,, ,��::',�„ p(� � 11ry„ _ ... r...,...,.,.<... ....ac. 1.... __.,.” w . ._ _ 1 .-. ' : _; 9 v” Pr -^b , � �: ?: '� `I1� � . a1 :L,,^ , ,: !� - "q, Cr :�, ✓+ ", >vt-Xa "v r,b v n,,, t,,,,, '..a,a {{,,q�pp � `, rk 'r'+ { .ii, a., ,,, ,I„ ,ti .... ,.., . ,,. _ a.: _.: �... . � :� t,y w r ^ .,:, �.. XI Pby,,'n � ...: �, �, .v „aN..,.r :: `., �aq, t ,'rt,,,, :, . "f / , k,,,ti, rn,V ",, r , � �Ir; ,,., .: . t4W ',: ,yF r1 ,? \ w r ,m'' u„ ,,,,y::r 5 ,:,�1 :�'ui a ^ '''.`•„:,.., � � r,N .} _ t yn p' a � d `z a 'r< b�5';d V4 <W �$t'.r ek,',d,:Ar G ,, .R ���,+rr,:��'�y .,._....wac... :'@E�"!, ','fir,+ m 'd:n;'�, .r KK, .,, Pt, n * �` ,µal:p f/ -to{{�°PPpp °✓, � ... .:.:. A" �,X�,��M '� „S^ .,F ., v., :�,,,: .:u,,,,� � :::„ , � �f � �_s., � ".�,, m 4r,'n,,i'f. > ��r v �,:C.. "1 W.''i . �a- AFY�i;+, :s`@,H r,4,,,;,`� a..__,«y.a_.r. ¢ ? qi ..';" .d'i,5,:, • ..v�}„s�,,. ... M%��k,i t " ^' I{ � �:, � �:.:: :�',. :^,., �I�� C „�,.,�. 'a :,� r„ I�. !, :: .ql,,,+ w. ," ."I:,,m„�,,,,, �::^ �: y; � t ;KK � , ..b ":I,. ,,r m V�.” ':'•: <i.J.�,Y�. .aa�i ' ' - - 1. <..wu.a...«rr... 71H -MC -CW @15cd 87; 174 j ..,__..__........aw:a �.....+s+-c.�s ...r✓x..,.✓u_. .w.w.«.,..t .aa.. � n ...._ YZH-MC-CW 30cci. .131 ZH-MC-CW @75cd22_2; 222; wCW tit cP._ d �. r «, 292 —2W -Md: ZR -MC -W @15cd i 64; 876 0 DEVICES -MC-CW @l5cd 69 ' ! 7 i TOTAL mA=. 1403 ] 14 247 22.211 1403 •Total Wire Resistance (R) Total Device Load, Amps (I) ;Voltage Drop ( E) j j (WL (Total ; (E= 24 * 2 * (R/ft) € 1.27 Cctad} Lv I * R) — E) , . ; " ` 1. ._0 40 1.79 22.21 EOL Voltage - m 7' y . 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 SYSTEM CALCULATIONS BPS • (BACK -OF -THE -HOUSE) S3-1 30cd S3-2 75cd S3-3 15cd S3-4 95cd S3-5 95cd S3-6 S3-7 95cd 15cd EOL S3 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE Z 0 J ix 0 w z w Z co Opo C� W c mo o UJ Q W Z LL! cf) (¢) 2t!) a ac o ; z D Q 0 0E. I- 0 W F - ' ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 14/ 16 BACKROUND PLAN PROVIDED BY SINGLE LINE DIAGRAM \ 0B NUMBER: 14381-1} SHEET FA -03 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved V MB MENIMMIIMEME ME MEIMEIMMIEMMI s, r e II • NEI S3-3 15cd D • 4 2C 0-" v (1Th 24,-0 /I / 2L,U„ X i , L x -x IMMEEMEIMMIEM 1-1 • VOID I� A; n E v Li 1 04'^"w- EOL S3 S3-7 EDDIE RCP, SUITT #2-1 S3-4 95cd a ® a ®m_s all IIIIIIIIMEINEENIE S— L TO EXISTING BOOSTER POWER SUPPLY • S S3-5 95cd x S3-6 95cd ® IMMEIMMEMEMs ® _ ®oo AREAF+ 128 -rE EASEE EINE a ▪ e ▪ - FIRE ALARM SYSTEM PLAN / I I i i 0" I — EASE A i` CL VOL7 }sE U (3-3) LEASE LEASE 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: C0 m 0 DESCRIPTION SHOP DRAWINGS DATE to N, 0 2 as<aa J /SCALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 14/ 16 BACKROUND PLAN PROVIDED BY: JOB NUMBER:14381-1_1 SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved \ J FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON 4.1 SHEET NU vi 3E SHEET TITLE FA -01 SYSTEM INFO MATIO\ FA -02 TYPICAL WRING A\ D N OU\TING DETAILS FA -03 SYSTEM CALCULATIONS A\D SINGLE LIN E D IAG RAN FA -04 FRE ALA SYSTEM PLAN SHEET INDEX 0 0 j. WiLhoUt Comments As t'` 1.+te.'.i in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau fori;,cnfOr,rkance with current City standards. Accept_anC is subject to error; and omissions which do not autnoriZe violations of adopted standards and ordina: s. The responsibility for the adequacy of design c -a is totally with the designer. Additions, deletiot is or v,siuns to these drawings after this date will void till' acceptance and will require a resubmittal of reviseu drawings for subsequent approval. . Final acceptance is subject to held test and inspection by The Tukwila Fire Prevention Bureau. Date: o'" 9- /)- By: NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. TIJKWIiA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. / a- - F -/71 and exact address for shut U ern ArlefflT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPUFPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPUFPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPUFPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPUFPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1 /8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.=.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHA_L BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE,. OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX EX EX EX 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1 G RING CEILING ® D DUCT DETECTOR AD2-P W/ SIEMENS HFP-1 1 DET. EXISTING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD DI FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXTN FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F. B.O. FURNISHED BY OTHERS N/A N/A N/A N /A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A NI/A GREEN BLUE AS BUILT REMOVE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND N/A N/A N/A N/A 743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE N co 0 2 ««< ALDO #670 m ervyers NORDSTROM 5 LEVELS 17,,275Cf ,./ES eFt21E i140ER ?0A FTS CAVERA JCPenney EAGD e ,ESS MACE MASviGICN '9Er:2S OFTcsscw S MC'I.ER-an MATE-, ,1. PAS, r.A SEARS Fox r.crrar RESTAL:AMT 710 PATO ATO Z cco c.--2 Z Q w W ZZ co CC Q W -(o I!L F- Z 0 1-1 0 W l•- (.1) (1/1) r SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 05/15/12 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved NUMBER: 55486 J SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ DEDICATED EMERGENCY NOTE: FOR 1CCflKNAL SPEEDTAIIONS SEE PRODUCT DOCUMENTATION. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 301.0C PEEZIE FRO1 GklJ A D TI] NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE MON XLS CONTROL PANEL (I' OR PREVIOUS ADDRESSABLE DEVICE - 0 II SL GROUI J 0 0 HTRI—R 0 e11 EOT ®A O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 PAD -3 oo INPUT INPUT TROUBLE NACI NAC2 NAC3 N1C4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 0 0 2 2 0 6k EOL (-) (+) (-) (+) 2 SPARE 2 SPARE 2 SPARE ( FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) WIRE DESIGNATION. NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPIJFPLR RED (JACKET) 'CONTACT RAIINOS 4.0A 0 125VAC 4.OA 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O C> Fel O I ®, I HTRI—R I ; J � t- 0 GROUND (+)) TO NEXT DEVICE OR (-) )' STOP IF LAST DEVICE DRY CONTACTS TO VAV _. FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY U U HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERAllViE: +32'F (0' C) TO 100'F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —` -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE rDATA IN(-)> Sl DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION HATH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL 0 0 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX EaY 7 \k. JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT /�— TO NEXT DEVICE ---CADDY BAR SMOKE/HEAT DETECTOR ----- SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL FAX (206) 628-4990 TEL. (206) 622-654.5 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE N Z to (0 0 2aaaaa Z coco O J c; -Z WO u.w z z c(/) O c= ©C cc0 W cc co D L1_ E— (SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 05/15/12 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 55486 SHEET FA -02 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved ALD , EXISTING SIEMENS ' Signal Extender Panel Battery LoadCalculations DESCRIPTION SHOP DRAWINGS Current Load: = ' IStandby: ' Z �J ' a") 2 <<<<< Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -CW ©15CD 9 0.069 SET -MC -CW ©30CD 12 0.111 SET -MC -CW ©75CD 5 0.2 SET -MC -CW @95CD 7 0.264 1.848 ZR -MC -CW ©15CD 13 0.069 ZR -MC -CW ©30CD 6 0.111 0.666 0.03 Amps 2.544 Amps Standby Current Load: 0.03 Amps For 24. Hours = 0.720 Amp -hours Alarm Current Load: 2.544 Amps For 5 Minutes 0.214 Amp -hours 25% Derating = 1.167 Amp -hours Total System Current Load: 1.167 Amp -hours Battery Pair to be Used 12VDC 7.2AH EXISTING FA JUNCTION BOX PROJECT: ALDO Panel: EXISTING PAD -3 BPS :Wire Resistance 2.58 Date: August 8, 2012 j CURRENT TOTAL= 1893.00 Notification Appliance Circuit Detail .... ., 2 SET -MG -:::11::::.c . . 111 . , - ' 222 SET -MC -CW @15cd 69 01 .......______ 1 1SET-MC-CW ©75cd 2001 200I 1 SET -MC -CW ,@95cd. . 264 . ' 264 1 3 iZR-MC-CW ©15cd 691 _ 2071 ZR -MC -CW @30cd .. -111 ' - . 0 . . DEVICES 17 TOTAL mA=1 893 14 328 SYSTEM CALCULATIONS cDEx EX S1-1 30cd V-1 I HT -R EX TSM EX EX EX s,v,v s,v,v s,v,v S1-2 15cd S1-3 15cd EX S,V,V Total Wire Resistance ( R ) Total Device Load, Amps (I) 22.491_ __ 8931 . . 67ci Load) 0 89 ,Voltage Drop ( E ) (E= I * R) 1.51 EOL Voltage - ' 24 - E 22.49 EX S,V,V V S,V,V EX S1-4 30cd V-2 S1-5 15cd S1-6 75cd V-3 S1-7 95cd V-4 EOL Si 1743 ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-651+5 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE Z �J ' a") 2 <<<<< cr 0 w z w co -J z co 0 E z mz o cf) z o 0 11-1(-9 0 zz uff ci) Z 0 < 2 0 < W CC D 17- 0 LLI C/) >0 - 'ALE: NOT TO SCALE DRAWN BY: O. GARCIA DESIGNED BY: R. VEZZANI DATE:05/15/12 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM \JOB NUMBER: 55486 SHEET FA -03 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved L(E) MALL CONCOURSE 28'-g"" TENANT LEASE WE K> 02 (E) ADJACENT TENANT SPACE - NO WORK TI -HS AREA TENANT LEASE LINE NEW CONSTRUCTION , NO WORK TI -115 AREA Co ii L ±1 STORAGE AREA LEASE LINE EOL S1 S1-7 95cd V-4 VACANT TENANT RETAIL SPACE 100 EX 95cd A L TENANT SPACE = NO WORK T?'IS AREA S,V,V S,V,V ST 00M I -5 15cd 4 4 • Nnipo 8 S1-6 75cd V-3 EX 75cd EX®o TENANT LEASE LINE 4E) ADJACENT TENANT SPACE - NO WORK TRIS AREA/ Co ♦ AI .. S,V,V 22'-6" V • m S1-4 30cd V-2 S,V,V S,V,V LANDLORD S TORAGE AREA 101 [ EX2 V-1 EX HT -R SI-3XXEx I 15cd S,V,V A n S,V,V S1-2 15cd v. EXIT EXISTING FA JUNCTION BOX TENANT LEASE LINE O �©USS CO - /5�,pK {� -x\-115 ����7 \\V)Wo /NO WORK TRIS FIRE ALARM SYSTEM PLAN FLAG NOTES: EXISTING SPEAKER/STROBE TO BE REMOVED. EXISTING SPEAKER/STROBE TO BE RELOCATED. cc el; 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS W N 1— Q 00 (D 0 0 co UJ oco O z (O � W w w z o 1 wI Cr Ir Co LL. W [1: 4-CALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 05/15/12 BACKROUND PLAN PROVIDED BY: J213 NUMBER: 55486 SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Ri hts Reserved \ .j � SII• 'S FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUIV 3ER SHEET TITLE FA -01 SYSTE INFO MATI O\ FA -02 TYPICAL WIRI \G AND MOUNTING DETAILS FA -03 SYSTEIv CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX pi Without Comments ❑ As N6 -.ed in Red ❑ Per The Letter These plans have been re'-iew u ;v The Tukwila Fire Prevention Burebu ,..161 current City standards. Acce p::er:c I. :i::Tors and omissions which cd of adopted standards anr:: t_ 1 n=r1<_ .. i ; ,..;.: ;,tiro/ for the adequacy of design che. de3igner. Additions, deletions or revisOns to `hese drawings after this date will void this e; car!ce '.':d w l require a resubmittal of revised drawings suoseci-ent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date:1-1)- - I Y By: Ali\ W SCHEISP3TEn.V NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing.. TUKWILA FIRE DEPARTMENT Pease call 206-575-4407 and give this Fire Permit No. and exact address for shut - on M -D U IT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT- FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 1 1 1 2 7 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD ❑a FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING )) FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F. B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND I 1, NORDSTROM 3 LEVELS 5 171,275sf t1CTORIAS SECRET P� « aP,�,& ETs. macys 4 LEVELS 250,407sf 3LS£P. i cc. Whai I I VANS SHOES #670 15.f, TCKr3 j krn Pf_iil PAID FEB 22 2012 TUKWILA FIRE W 0' FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS w r- 02/17/12 0 2 a<CCa 2 4CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/ 17/ 12 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved .0B NUMBER: 55416 FA -01 SHEET THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60H2 �I DEDICATED EMERGENCY 111 NOTE FOR ADORltNAL SPEfl1CA1IONS SEE PROOUCT DOCUMENTATION. *CONTACT RA11NGS 4.0A 0 125VAC 4.OA 0 30VDC TO NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE s - FROM XLS CONTROL PANEL (I OR PREVIOUS ADDRESSABLE DEVICE D 0 GROUND I L 0 0 HTRI—R 0 O 0 O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) ° ORO N L a 0:1 110 11 II 0 PAD -3 oo[1 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - S 0 .1.Q-11-Q111s211-21[-Qtca 3.6k EOL (-) (+) (-) (+) 2 SPARE SPARE (2 SPARE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLORCODE TWISTED PAIR WITH SHIELD #18 FPLIFPLR RED (JACKET) 'CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. D 0 F7-10 00 GROUND g HTRI—R 1 0 DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. 0 (+)> TO NEXT DEVICE OR (-) (-) STOP IF LAST DEVICE DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL + `J HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY + U HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERATURE: +32' F 0' C TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR — DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL o0 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE //- STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT JUNCTI❑N BOX MOUNTED ON CEILING FLEX 00 I TO NEXT DEVICE CADDY BAR I SMOKE/HEAT DETECTOR \\— SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved c0 0' O I- z_ (J) LU I— F-- LU U) F- O U) U) r- FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: _I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE c\1 sc t` N 0 2 aaaaa Z co co Q J� C11 <O) w c 2z O< cco = w zZ Ci) ZLI.. = w 0 W cc co LL �-- SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/17/12 BACKROUND PLAN PROVIDED BY: J.0B NUMBER: 55416 SHEET FA -02 , , a, ' DESCRIPTION SHOP DRAWINGS Current Load: DATE Standby: Alarm: ' ' , ' Z N a Device Type Qty Amps Total Amps Total Amps HFP-11 1 0.0022 0.0022 0.0023 0.002 AD2-P 1 0.0635 0.0635 0.064 0.064 0.030 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0875 al -MC -CW ©30CD 2 0.131 714 -MC -CW ©75CD 3 0.222 ZH-MC-CW ©95CD 0.0731 Amps 0.106 Amps , , a, , DESCRIPTION SHOP DRAWINGS DATE Y Sndby, ' ' , ' Z N a 2 <<<<< Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 714 -MC -CW ©15CD 1 0.0875 al -MC -CW ©30CD 2 0.131 714 -MC -CW ©75CD 3 0.222 ZH-MC-CW ©95CD 1 0.292 0.292 ZH-HMC-CW ©115CD 0.371 IZR-MC-CW ©15CD 3 0.069 0.207 714 C -W ©15CD 0.064 0.03 Amps 0.529 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.529 Amps For 5 Minutes= 0.044 Amp -hours 25% Derating= 0.956 Amp -hours Total System Current Load: 0.956 Amp -hours Battery Pair to beUd. 12VDC Amp -hours 7.2AH Notification Appliance Circuit Detail PROJECT:IVANS SHOES Panel: !PAD -3 BPS Date: February 20, 2012 'Wire Resistance 2.58 CURRENT TOTAL=11514.00 1 ZH-MC-CW @15cd j_ 87 87 2 ZH-MC-CW 430cti 131 262 3 1ZH -IVIC-CW @75cd 222j 666 111 -MC -C14 @95cd — 292 292 IZH-MC-CW 0.115cd 371 0 3 ZR -MC -CW @l5cd 69 207 DEVICES 110 TOTAL mA= 1514 (Total Wire Resistance ( R ) Total Device Load, Amps (1) . Voltage Drop ( E ) EOL Voltage 14 166 • • i( WL* 2 )* (Rift) I 0.86 (Total Cct Load) 1.51 1.30 24 E) 22.70 I(E= * R) 2C TO NEAREST EXISTING? SIGNALING CIRCUIT 120VACI DEDICATED (BY OTHERS) ( TO NEAREST EXISTING DATA LOOP SYSTEM CALCULATIONS S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 S1-8 S1-9 S1-10 15cd 75cd 95cd 30cd 30cd 15cd 15cd 15cd 75cd 75cd 13LHT-R4 D,I I HT -R1 21 TSM I FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110VAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME EOL ROOM/AREA AS THE PAD -3. Si DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 om DESCRIPTION SHOP DRAWINGS DATE Z Z N a 2 <<<<< cc 0 z co z co Z Cf) < z 07-A- 20 ‘41 0 < 1190 1- 1- Z Z Z Cis) Ill 4=C Cl) z 0 C.)U) Cf) < 2 f_ Z CC citt 0 ><° w ciz). cc (oLL In 0 47t-1 0 LLI F— Cl) >- C/) 4-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:02/17/12 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM JOB NUMBER: 55416 I. SHEET FA -03 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved r I ►; n! I- ELI- CIF- nr-- I Nr, KY „ ! SYh•MPOL MANUEACTJPE ; / DESCRIPTION A ( f, PENDANT MOUNTED HIGH HID BAY FIXTURE AT XX'—X" A.F.F. B2 RECESSED. ADJUSTABLE COMPARTMENTAL LIGHT FIXTURE HOUSING I \\ BJ CONTECH ;iRAN15038—X3—B-21L BL RECESSED, ADJUSTABLE COMPARTMENTAL LIGHT FIXTURE HOUSING � A,71-7; :J • 2 aaa<a STOCK ROOM: CON—TECH fRL38-21LBL;' 6" RECESSED DOWN LIGHT WITH 21 WATT LABEL. SPECULAR REFLECTOR & WHITE TRIM NO CEILING. (OPEN TO DECK ABOVE) THE TENANT'S G.C. SHALL PREPARE THE CEILING AREA TO BE EXPOSED. RUN ALL CONDUIT, PIPING, DUCTWORK, ETC PARALLEL AND PERPENDICULAR TO THE DEMISING WALLS. REMOVE ANY UNUSED OR ABANDONED EQUIPMENT OR PREVIOUS CONSTRUCTION. THE STOCKROOM AREAS ARE TO REMAIN UNFINISHED ONCE EXPOSED. SILVER LIGHT TRACK _ENG , PER PLAN ( D2,4,6,8,12 E �� DECORATIVE PENDANT LIGHT F WITH SURFACE MOUNT SATIN NICKEL FINISH CANOPY ( 2 LAYERS 5/8" TYPE "X" GYP. BD. EACH SIDE OF 3-5/8" X 20ga. METAL STUD FRAMING. SEE DETAIL E/A6. TAPE, SAND SMOOTH, PREPARE FOR PAINT FINISH. EF I.`• RECESSED EXHAUST FAN — SEE MECHANICAL SHEETS F U CON—TECH LIGHTING fCTL838/2—U PAR38 ADJUSTABLE TRACK FIXTURE WITH BLACK FINISH. H4 4' FLUORESCENT OPEN STRIP LIGHT SUSPENDED AT 14' A.F.F. UNLESS NOTED OTHERWISE I I H8 8' FLUORESCENT OPEN STRIP LIGHT SUSPENDED AT 14' A.F.F. UNLESS NOTED OTHERWISE 4' OPEN STRIP LIGHT MOUNTED TO SUSPENDED CEILING GRID I i I I WALL MOUNTED FLUORESCENT FIXTURE MOUNTED OVER LAVATORY K I ! ! I TRACK SECTION WITH NATURAL ALUMINUM FINISH. LENGTH AS DESIGNATED. LE,4,6,8,12 SURFACE MOUNTED LED ILL JMINATED EXIT SIGN -12 _ X' SURFACE MOUNTED EDGE .. i EX:T SIGN WITH UNIVERSAL MOUNTING CANOPY SURFACE MOUNTED EMERGENCY LIGHTING UNIT WITH SEALED BATTER BACK—UP S I SPEAKER ABOVE PAINT LINE FURNISHED AND INSTALLED BY OWNERS VENDOR (TYP.) 0.0 TO COORDINATE LARGE CEILING MTD. S!UPP'_ AIR DIFFUSER. SEE MECHANICAL PLAN FOR EXACT SIZE. ®i SMALL CEILING MTD. SUPPLY AIR DIFFUSER. SEE MECHANICAL PLAN FOR EXACT SIZE. ! ! I! 1 RETURN AIR GRILLE. SEE MECHANICAL PLAN. I I SMOKE EXHAUST GRILLE. SEE MECHANICAL PLAN. Z. / NOTE: SEE SHEET E3 FOR COMPLETE LICHT 1 FIXTURE SCHEDULE I '(-) nr-- I \I' Impl-- c SALES AREA: DESCRIPTION SHOP DRAWINGS NO CEILING. (OPEN TO DECK ABOVE) THE TENANT'S G.C. SHALL PREPARE THE ; CEILING AREA TO BE EXPOSED. RUN ALL CONDUIT, PIPING, DUCTWORK, ETC PARALLEL AND PERPENDICULAR TO THE DEMISING WALLS. REMOVE ANY UNUSED OR ABANDONED EQUIPMENT OR PREVIOUS CONSTRUCTION. IN SALES AREA ONLY PREPARE ALL SURFACES ABOVE 12'-0" TO BE PAINTED INCLUDING DECK, STRUCTURE, EQUIPMENT, PIPES, DUCTWORK, ETC. MASK OFF ANY IDENTIFICATION LABELS ON ANY MALL OR TENANT UTILITIES OR EQUIPMENT BEFORE PAINTING THEN REMOVE LABELS BEFORE TURNOVER. COORDINATE WITH THE CENTER MANAGEMENT ANY UTILITIES (SUCH AS LIFE SAFETY LINES R DEVICES) THAT ARE NOT ALLOWED TO BE PAINTED. USE COMMON SENSE BEFORE PAINTING. I \\ GYP. BD CEILINGS: � 5/8" TYPE 'X' GYP. BD (AT HEIGHT PER PLAN) ON 3 5/8" x 20ga. METAL STUD FRAMING (PER DETAILS) TAPE, SPACKLE & SAND SURFACE. PREPARE FOR PAINT OR OTHER FINISH PER PLANS. 2 aaa<a STOCK ROOM: ! I NO CEILING. (OPEN TO DECK ABOVE) THE TENANT'S G.C. SHALL PREPARE THE CEILING AREA TO BE EXPOSED. RUN ALL CONDUIT, PIPING, DUCTWORK, ETC PARALLEL AND PERPENDICULAR TO THE DEMISING WALLS. REMOVE ANY UNUSED OR ABANDONED EQUIPMENT OR PREVIOUS CONSTRUCTION. THE STOCKROOM AREAS ARE TO REMAIN UNFINISHED ONCE EXPOSED. REAR VESTIBULE (2 -HR RATED): 1 2 LAYERS 5/8" TYPE "X" GYP. BD. EACH SIDE OF 3-5/8" X 20ga. METAL STUD FRAMING. SEE DETAIL E/A6. TAPE, SAND SMOOTH, PREPARE FOR PAINT FINISH. ILLUMINATED EXIT SIGN WITH BATTERY BACK HP LUX BEAM TO BE MOUNTED AT 12'-0" A.F.F. COORDINATE WITH VANS PROJECT MANAGER BEFORE INSTALLING. CL -i OPEN TO DECK ABOVE — PAINT OPEN TO S1 -EQ CL -2 10'-0" A.F.F. PAINTED GYP. BD. , CL -2113'-5" A.F. PAINTED GYP. BD. • ;_—STOREFRONT SIGN FRAME. SEE STOREFRONT ELEVATION. \\ \ \`�, \ V (i0-0 A.F F. 10'-0" A.F. it TO NEAREST D EXISTING DATA LOOP TO NEAREST 2C EXISTING 2 6 SIGNALING CIRCUIT L UX BEAM TO BE MGUNTED AT. 12'-0" A.F.F. COORDINATE WITH VANS PROJECT MANAGER BEFORE iNSTALLING. '—ICL -1 OPEN OPEN TO DECK ABOVE — PAINT FIRE ALARM SYSTEM PLAN 3" FIRE SPRINKLER MAIN 13'-11" A.F.F. / ,-ICL-3I OPEN /ABOVE NO OPEN TO DECK / PAINT N 1 // -5" A.F. FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. JI j " S1t4 // 30cd 0 m CL -2 .!0 O A.F.F. PAINTED GYP. BD. TO S1-9 CL -2 PAINTED GYP. BD. A.F .F. S1-2 75cd EXIST. GYP. BD. CEILING, PAINT. 3" FIRE SPRINKLER MAIN 13'-11" A.F.F. • LINE OF COMPRESSOR LOCATED ELSEWHERE, SEE Mi: FIRE ALARM SYSTEM PLAN (CON'T) OPEN OPEN TO DECK ABOVE NO PAINT Iw z J z U F - Q r0 CO 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m D DESCRIPTION SHOP DRAWINGS I \\ 02/17/12 2 aaa<a \\ \ \`�, \ V (i0-0 A.F F. 10'-0" A.F. it TO NEAREST D EXISTING DATA LOOP TO NEAREST 2C EXISTING 2 6 SIGNALING CIRCUIT L UX BEAM TO BE MGUNTED AT. 12'-0" A.F.F. COORDINATE WITH VANS PROJECT MANAGER BEFORE iNSTALLING. '—ICL -1 OPEN OPEN TO DECK ABOVE — PAINT FIRE ALARM SYSTEM PLAN 3" FIRE SPRINKLER MAIN 13'-11" A.F.F. / ,-ICL-3I OPEN /ABOVE NO OPEN TO DECK / PAINT N 1 // -5" A.F. FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. JI j " S1t4 // 30cd 0 m CL -2 .!0 O A.F.F. PAINTED GYP. BD. TO S1-9 CL -2 PAINTED GYP. BD. A.F .F. S1-2 75cd EXIST. GYP. BD. CEILING, PAINT. 3" FIRE SPRINKLER MAIN 13'-11" A.F.F. • LINE OF COMPRESSOR LOCATED ELSEWHERE, SEE Mi: FIRE ALARM SYSTEM PLAN (CON'T) OPEN OPEN TO DECK ABOVE NO PAINT Iw z J z U F - Q r0 CO 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m D DESCRIPTION SHOP DRAWINGS DATE 02/17/12 2 aaa<a Z co OJT 17-7 c z 0 w "< w 0 Z zz CD 2 Z ti - O W LL cc �I— �CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/17/12 BACKROUND PLAN PROVIDED BY: 1.0B NUMBER: 55416 J Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved \ SHEET FA -04 , O Without Comments o As Noted in Red IC Per The Attached Letter • The plans have been reviewed by The Tukwila Fire r,wention Bureau for conformance with current City ndards. Accept aoce is subject to errors and oi-ii;sions which do not authorize violations of adopted :::i.tdards and or .rices. The responsibility for the • ,1decivacy of design totally with the designer. • Additions, deletion.y. .-,Visions to these drawings after • this date will void ':.rr• (.-:(..:eotance and will require a resubmittal of rvseddrawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prtlentlo:ureau. Date:_2- -2 (0-11p_ay: C 1 -:1D7 and f'Q c-TiTR No. - 3)-- • • and a for chut- c:iown or rastaifdan zpprovL CHAIN HUNG FLUORESCENT STRIP LIGHTING MOUNT I 3'-0" ± A.F.F. VERIFY HEIGHT WITH DUCTWORK - 5LI3PNDQ FROM STRU DOVE (TYP.) STO9KROOM l0 ST UCTURE PEN I * JLJLJ 7'-3" 94.-0" FlexHead Sprinkler Drop . Cofrugated Stainless steel hose with stainless steel brai available in 2', 3',4',5 & 6' legnths . • . - . . • Multi -Port Bracket - Adjustable Hub FLEYBEAD INOUSIRIEVVF . • • • F.10xhebd -bbmniexcial Ciling Unit T -Bar Ceiling Installation Model #2024,036,2048,060,2072 I '-0" r\i• LINEAR FEET OF TRACK 5TRUCT. OPEN I <I- <I • < STRUCT. [OPEN MN, •••••••••• 101•11=110•111, 11110 ••••IMINNO I OPEN] 7 9/ il17-71/&/ HALLWAY 08 STRUCTURE OPEN V VV. ri 0 / aa # z II 41 VV • _ . GYP. BD. ✓ -O" SHOE STORAGE ok.5 GYP. BD. ✓ -O! •VV• VV vv, LQ I L VV VV V\7 .7— : - TRACK WITH TRACK . HEADS - MOUNT . TRACK TO AT -. • I 2'-0"± A.F.F. VERIFY HEIGHT 'WITH DUCTWORK • SUSPEND. FROM STRUCTURE AND -LOCATED AS SHOWN A • #1 A 1 A • FTRM HALLWAY. 02 STRUCTURE • : OPEN ani • • A • A A A •• • • r •1 - I I I I .1 . . RETAIL I oi STRUCT1.1 OPEN ' • : I U • UV' 4a '64a • aa V 011••••••••• •••••••••• .011011••••1111; U IMI/01•111 0 aa.• aa • ••111111111••••• ••••1•111114 V. 0•111•00•111. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAN/ C-CLAPP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING • • .... ••• STEEL JOIST/TRUSS HANGER DETAIL NTS G'V VV ,n,11 • LL 1•1•1•111111•110 IMP • L4. .• 12'-Q" • d -tu • b . o ARAKAWA CRI3 kAft:AriAerip .: - . • TO SOFFIT, 13IACK (F.O.I.C.) ;.• • • - IL.: • MOUNT PER MANUFACTURE'S -; itl -• • - . SPECIFICATIONS . - ' • • • DRAKE METAL I 2%-0'. RAKE METAL-. 12'-0" 0 TmOouSNOTFFPIET ARAKAWA CRP) RAIL ATTACHED. 13MLAANCUICF(ArCT.CIULREC.S) tu. 0 SPECIFICATIONS ••.• . , .- • • • • . 4: ta mmmmmmmmmm -a *LOT CEERTWI FIRE PROTECTION SPROAKLER SYSTEMS John J. Abel 9760 -0591 -Ce . Level 3 • , prot, , .• - Inm• ' l: ""11- -411 AIL 111. ••• REFLECTED CEILING PLAN w TRUE NORTH PLAN NORTH • LINEAR FEET OF TRACK Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 1— Add Globe Model GL5661 Standard Response 155° Brass Upd Y2 x o E — Existing no change O 4— Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x A7Ze 11,4) ike TENANT LOCATION MAP SPACE #0212 Lever! ate MALL KEY MAP ars - • CROWN FIRE PROTECTION INCORPORATED " P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Eddie Bauer • 670 Southcenter-B-1-vd Space 212 Tukwila, WA • PAID FEB 17 2f116 TUKWILA FIRE .12,975/ 7oz2— DATE: 2- g. DRAWN: (AT - SCALE: 3/1(o -Without Comments As Notes i,te.: Per The Attaci '.. atter ' e plans have.t)eer reviewed by The Tukwila Fire -'ention Sure -cu _,1iformance current City .;.Dards. ,L subject to errors and ;:;.,ions tit+?? r` :i tnorize violations of adopted • ;:yards anc The responsibility for the .-quacy o: :. i-; lot&l:y with the designer. .rt?ns, de{et;i;. .,Dior;; to these drawings after s date will void r .. .;,.ptance and will require a ( ;ubmittai of , .•;.: a sings for subsecluent•approval. l nnl acceptance +.o rleld test and inspection by Tukwila Fire " :=, 3r,,.n Bureau. Date:1—:1S-1So €3v: TUKWILA FIRE DEPARTMENT c- ;i 206-575- ' 07 cad Give Vii':{ Fire w Per ii 2 3L No. _/Co -S -Q02 • EXISTING EXTERIOR SIDEWALK EXIT # 2 (1) @ 36" CLEAR 180 OCCUPANTS 2 SPACES = 90 OCCUPANTS PER SPACE ord o►. d� w EXIT6Qi iu O� G1- N EXIS 1 -HOUR RAT T NANT DEMIING WALL TO REM , N n► U 4. N 0 Qa a 0a, EX T96 OCC. OR 01 o p' 0 Q, contractor shall patch and -epair existing wall to maintain 1 hour rating Ock OR OR ►,1 R 1 PR 30SF-= 12 64 O� h OR 01. THIS P RMIT SET DELINEATES THE NDLORD SCOPE OF WORK ONLY. FULL TENANT IMPRO EMENT DRAWINGS WIL BE SUBMITTED UNDER SEPARATE PERMi THERE WILL BE NO (DfN OCCUPANCY UNDER THIS PERMIT O(z Op. 1- \14>___ • EXIT # 1 (1) @ 72" CLEAR 0 OCCUPANTS BY TENANT Of QR SCALE: 1/8" = 1'-0" MIN Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 11- Add Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 o 33 - Relocate Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 o E - Existing no change TOTAL = 44 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTs >I' Opy CERTIFICATE OF COMPETENCY RE PROTECTION SPRINKLER SY John R =1 G ,016,„.441, S BUILDING SITE KEY PLAN AD 12 • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 EDDIE BAUER LANDLORD SCOPE 670 SOUTHCENTER BLVD. WESTFIELD SOUTHCENTER TUKWILA, WA 98188 PAID DATE: 5 DRAWN: ( SCALE: • Z,F7 z z 4,25't' 'IS [ofy. EGRESS DOOR O@36"CLEAR 180 OCCUPANTS EX T96 OCC. OR 01 o p' 0 Q, contractor shall patch and -epair existing wall to maintain 1 hour rating Ock OR OR ►,1 R 1 PR 30SF-= 12 64 O� h OR 01. THIS P RMIT SET DELINEATES THE NDLORD SCOPE OF WORK ONLY. FULL TENANT IMPRO EMENT DRAWINGS WIL BE SUBMITTED UNDER SEPARATE PERMi THERE WILL BE NO (DfN OCCUPANCY UNDER THIS PERMIT O(z Op. 1- \14>___ • EXIT # 1 (1) @ 72" CLEAR 0 OCCUPANTS BY TENANT Of QR SCALE: 1/8" = 1'-0" MIN Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 11- Add Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 o 33 - Relocate Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 o E - Existing no change TOTAL = 44 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTs >I' Opy CERTIFICATE OF COMPETENCY RE PROTECTION SPRINKLER SY John R =1 G ,016,„.441, S BUILDING SITE KEY PLAN AD 12 • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 EDDIE BAUER LANDLORD SCOPE 670 SOUTHCENTER BLVD. WESTFIELD SOUTHCENTER TUKWILA, WA 98188 PAID DATE: 5 DRAWN: ( SCALE: • Z,F7 z z 4,25't' 'IS [ofy. 670 SOUTHCENTER MALL ASSOCIATED PERMITS 16-F-027 16-F-015 12-F-179 12-F-039 16-S-032 16-S-007 16-S-003 4.41Mci J 1� SITE LOCATION Site Address: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. _ \ 5 7 0 **PLEASE PRINT** X355 S. 1z., " pi King Co. Assessor's Tax No.: Suite Number: Floor: Tenant Name: %() V V S — S 0 e TI New Tenant? ❑ - Yes IFf..„No Property Owner's Name: J p b C Y — o �i-- f�'C A s Mailing Address: J 3 7 S, 1 Z J ti k to 't ' Ar City State Zip CONTACT PERSON -if there are questions about the submittal. Name: 2 0 .' U J Day Telephone: Z- O b 3 T 0 0 1 Company Name: Az_C e� Q p Mailing Address: ?- h- l� e LAJC›-v (01 — d 6 S _ City State Zip E-mail Address: C� V CO" t C- e— (14. t e"E- .0 d ►`t Fax Number: L Z j 5 6 7 6 6% 2 ‘c e - 3 1 T Valuation of Project (contractor's bid price): $ r7 , 3 7 a-1- New e V t c e, Scope of Work (please provide detailed information): it) 9 P V t C P_C T J PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNS' ORA - i ° ED AGENT: Signature: Print Name: Plan Permit App.doc Day Telephone: Date: S l a ('a crs5 vt)3 5/14/10 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 67D 5(0/He/pied- ),7a1/ Suite Number: , Floor: Tenant Name: die Uver. Property Owner's Name: \)j T \eA ?'rCS Mailing ?. Ni(Nyyr'r. Address: CONTACT PERSON -if there are questions about the submittal. Name: Company Name: New Tenant? ❑ - Yes ❑ - No City State Zip Day Telephone: Cohn Mailing' Address: PO SOX ale )97//1 WA- f ti & city E-mail Address: ��S'CQ. Pr _�NYtCQ %�'] Fax Number: 9Z6470-7,6 t� • Total number of new/relocated devices or sprinkler heads: 1714i Valuation of Project (contractor's bid price): $ 8� D .' Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. _ I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING S - ER OR AUT . ORIZED AGENT: Signature: Print Name: Plan Permit App.doc 1/2/13 Date: / 6 ` a Day Telephone: 4'2 %'l7lyi2 9 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470130 Site Address. 21 Southcenter Mall, Space 670 Tukwila, WA 98188 Suite Number: Floor: Tenant Name: Eddie Bauer New Tenant? - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept Mailing Address: same as site address CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 City State Zip E-mail Address: kveliz guardiansecurity.com City State Zip Fax Number: 206.374.2852 Total number of new/relocated devices or sprinkler heads: 7 Valuation of Project (contractor's bid price): $ 5,500. Scope of Work (please provide detailed information): Add 7 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING I WNER OR A THORIZED AGENT: Signature: JQ Date: �71Z1(Ci° Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION 9202470130 King Co. Assessor's Tax No.: Site Address: 6$0 Southcenter Mall Blvd, Tukwila, WA 98188 Suite Number: Floor: Tenant Name: Eddie Bauer Store Property Owner's Name: Westfield Shopping Center New Tenant? J - Yes 1:1- No Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206-349-5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City State Zip E-mail Address: Fax Number: 205.374.2852 Total number of new/relocated devices or sprinkler heads: 20 Valuation of Project (contractor's bid price): $ 6000 Scope of Work (please provide detailed information): Add 20 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING . . N R OR AUTHORIZED AGENT: Signature: Date.GZ Print Name: Karina Veliz 206.349.5889 Day Telephone: Plan Permit App.doc 1/2/13 TFD FP Form 8 Otrit"44 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: (ID Sour/1621RA 13 I Vd Tenant Name: Property Owner's Name: Mailing Address: CONTACT PERSON -if there are questions about the submittal. King Co. Assessor's Tax No.:o. Suite Number: G /2, Floor: New Tenant? ❑ - Yes n_ No rrang Name: Nirfa Company Name: City State Zip Day Telephone: 4425:— t//— 7K 4 9 'V0tu1 Fir prOk6eAlThl MailingAddress: l C)S /c7113, (U) arUX tJl 9gOtZ E-mail Address: ) I S i Ca (v O "VP 7( City/Fax Number: 1.4,25--1.4,25--y� 9r Total number of new/relocated�devices or sprinkler heads: /3d d 5 Valuation of Project (contractor's bid price): $ i 00 .0/ Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Plan Permit App.doc Thenv Date: 27//Wgi__ Day Telephone: 1/25' 7U �'` 7 &el 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Eddie Bauer 670 Southcenter Mall Permit No.: 16-S-007 Date: January 15, 2016 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Eddie Bauer 670 Southcenter BI Permit No.: 16-S-032 Date: February 26, 2016 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. Jan 11 16 04:46p Crown Fire Protection FAX TRANSMITTAL 4254818695 p.1 Fax No. CROWN FIRE PROTECTION, INC. ®= ECM 1.11.16 Fire Prevention Bureau Tukwila Fire Department i Al Demo Permit Number of Pages (Including Cover) ❑ Urgent H For Review 1 206.575.4439 'LA F7.7,7 CZPAR7772:717 :. ,1: Z G -:75-4:e.,07 'r ctoivn or natartIVOnCppinOvelo 0 Please Comment 0 Please Reply Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comments We need a demo permit to remove (4) heads that are in the way of the new wall at the Eddie Bauer Landlord Work Project — 670 Southcenter Mall. The building permit 4 is D15-0265. Please let us know if you have any questions. Thanks CErRT,F�OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS q P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425. 481.8695 'TUKWILA FIRE DEPARTMENT Ram call 206-575407 and gsvQ this Fire Permit Pio. /(e -F-01.7 and exp addmss for 2hut- down Cly ' f'i l prpmv LL EDDIE BAUER STOKE T.I. FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL WIRIN G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FI E ALAR VI SYSTEM PLAN SHEET INDEX Without Comments As Nosed in Re0 Per The Attached Letter plans liafe b_._!n reviewed by The Tukwila Fire >,r�ion Bureai.i foo .:onformance with current City �!"ds. Accept i:' • - .'i ,;tioject Yo errors and which cr' :.. '• ht ftt nrize vi0lations of adopted r .3iC1S �al�a rat t3:, i: >, Tne responsibility for the y cY de& Ot lly with the designer. '1elet,orl;-, to these drawings after is ,f,,ta Voici i ::-.1ccaotance and will require a rr�.,T ,rnitta! ,;r nevi e(i ,:z,• : -a,nrs rnr subsequent approval. Firal acceptance I;., sub,ct tleld test and Inspection by 11^de Tukwila Fire PrevF:rition B eau. Date: )-_j a-- I Co By: NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be pi-cs .ted to the Inspector ps r to commencement of ,acs:-l� nce Testing of any r it and Detection ys. • Failure of test wiii in a Re -inspection termination of the to WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA UNE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPUFPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPUFPLR RED (JACKET) REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 2 2 3 6 7 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER Ex POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING DUCT DETECTOR D AD2-P W/ SIEMENS HFP-1 1 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX ' VERIFY IN FIELD ai FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND • 5 NORDSTROM 3 LEVELS V 1/ 171,275sf macy 4 LEVELS 250,4070 EDDIE BAUER STORE T.I. #660 FUMC • 1-1 ti7Et}I, PE aROM OtVAILAR PEW { ,121.551 3 k GOLD Lvi;� 1T s n I wr_4Lv RED P�=t. E:Unt, ueP,P, fKO ERS �,� 1, ELLR2 1 JCPenney L£4EL 2 E,466st Q PAID �i, FF9 -3 211M,/// TUKWILA FIRE 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE M 0 N 0 2 CCCCC b) w O T 00<z 1-QOt- H CCW w = In CD =¢ CO U) Q 0 LL E- 0 w W (1) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/03/16 BACKROUND PLAN PROVIDED BY: \ OB NUMBER:15148-1 j WIRE DESIGNATION GENERAL NOTES SITE PLAN c 42/ Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 } THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE; SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6011Z DEDICATED EMERGENCY N015 FOR ADDITIONAL SPECIFICATIONS SFE PRODUCT DOCUUt:NTA110N. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VOC ME MN TO NEXT ADDRESSABLE f+ DEVICE STOP IF LAST DEVICE - FROM XLS CONTROL PANEL + IR PREVIOUS ADDRESSABLE DEVICE - 0 FROM PREVIOUS (+) ADDRESSABLE > DEVICE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 5 m 0 0 P1 m 0 5 m m r N o 0 0 FITO C 0 F, m (-)(-) (+)(+) EPEE (+) 0 WIRE DESIGNATION, NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIED) #18 FPLIFPLR RED(JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 3010C FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O T. ;I ° © © -L J4 HTRI—R Ilg cI J O O ° GROUND DRY CONTACTS TO VAV --..>. FAN SHUTDOWN PROVIDED BY MECH/ELEC. (+)>TO NEXT DEVICE OR (-) STOP IF LAST DEVICE DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FLED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL 'I _I HTRI—R INPUT INPUT TROUBLE NCI NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NO C NO + - + - + - + - + - 3.6k EOL C -CABLE SPARE SPARE j SPARE C -CABLE (—) + v HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +322'' F (0' C TO 0(1 F (38j C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —� –� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE • DATA IN (-) >--- DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING /- HORN STROBE STROBE ONLY DROP CEILING MOUNTING • HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR "- SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 z 0 UJ w Q Lu J W REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE M 0 N 0 2 CCCCC ■ I- o W O Orn O 20 I— < cd t- (/) w 0 CC W WT w co0� IT -44c ac� m !C (q _ CC c0 0 W I (6 w 0 c� z F- O 0 z z J U 4-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/03/16 BACKROUND PLAN PROVIDED BY: JOB NUMBER:15148-1} I SHEET FA -02 `Power A FIRE ALARM BOOS TER POWER Project: EDDIE BAUER -STORE T.1. SUPPLY SUPPLY (mA) BATTERY Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Panel: 1 EXISTING PAD -3 BOOSTER POWER Date: ; February 3, 2016 Qty Mod ule/DeviceStandbyTotal Module 1 30 30 0 30 30 0 TOTAL FIRE ALARM POWER SUPPLY 30 30 .I B':,Auxiliary Device Current 0 0 C ©75cd -CW 95cd ; Notification Appliance Load (Max_ Total I mA) 0 5772 _ t __ i a@15cd -CW + 15cd D E F G H I J K Total(A)= 30Total(B)= 5802 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 30 5802 Total current ratings converted to amperes (line D x .001) 0.03 5.802 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 .M,et. .Y, yry3"S .,�„ v ,.', `rY m✓.. "', �� - k r; 'M',xv °1tf ''.'"' dp r4::', y ^,• i; a',:';,<: �: ;, ,N"a;.�. -�r n r,�\";:-" � .jk ,. ?'�. (�,^ t �.��, � A ° .I m, �l,.,: �'.,� �,,,. � ,� M .� ,,,, S, � � �.a - la \� t Y �.r'ry � � E'. �,. � v „� s ���1, .,,� ,.,,m x „"�,. '., _ ,� w�,,r, tl „vk rv, v,i " +, ”, . 7,w',.P :...o , n n t ., w^ . , rt � r ... � M"W, � Cm., � ,.. ,r;'C. °I, �u.,�,^, 1".f.. 1 h„ �„� .. ..,, .A a,l r' a. : rv,yWv .., "�,, �,� :r !^I ,^*:��. w �°, „.,. r ,” •,, - Multiply lines E and F . Total Standby AH 0.72 I' b''. r u, :i"','+1,4�rw + '.W,;,x. , q u�, k ,A +"I�t,w r >,,., • o �^' P$: a. �. Mr .�„M ��, .,', �. X �,;, � Alarm sounding period in hours (5 mins+ .0833 hours) _.."..:'. Mr\''�', � *, r ��n �„y�'I 0.0833 Multiply lines E and H Total Alarm AH ; TOTAL Wire Resistance (R)( Device Load, Amps (I) u. Drop�(E i _ � _ 0.4833066 Add lines G and I Total Standby and Alarm AH 1.2033066 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 1.44396792 _ _ __, 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 PROJECT: EDDIE Notification Appii nce Circuit Detail 2.58 5772.00 BAUER - STORE T.I. POWE SUPPLY Wire Resistance CURRENT TOTAL= Panel: ; EXISTING PAD -3 BOOSTER Date: February 3, 2016 ' r a k""fi.,,r.w,�„ uv %k9V'#'k�m arY I�mjnww\, .'�'��°,, '^.�id a •a l 2 ZH-MC-CW 3 ZI*41#C 1 ZH-MC-CW C ZR•MC-W _ 2174. -MC DEVICES 13 Total Total _____ ValtageDrop4(E) L Voltage i m,uaa,";'( :M"* Nx, rmmm'ni„ J k'I ;. i r�.'' m" m,f�r ,v �d (f�ly. r-�(ta�, +`�''�'t 1 C r m a©15cd CW 30cd 87 131 222: 292 , �� 174; 393 � ' .I o cul N6 qq�N k r4, ©75cd -CW 95cd 222; 0 0` 483 _, . ._ i 272 ` 14 �_____, ��E�� _ t __ a@15cd -CW + 15cd 64 69 mA= _ _�_i.__,. .. . ' TOTAL Wire Resistance (R)(W Device Load,' Amps (1} +.. +rk, 278 22.18' 1272 2) * (Rift) (Total_Cc Load) 43 1.43 1.27 . 1.82 1.82 �__ ,_(E= I * R) 24 E) 22.18 .M,et. .Y, yry3"S .,�„ v ,.', `rY m✓.. "', �� - k r; 'M',xv °1tf ''.'"' dp r4::', y ^,• i; a',:';,<: �: ;, ,N"a;.�. -�r n r,�\";:-" � .jk ,. ?'�. (�,^ t �.��, � A ° .I m, �l,.,: �'.,� �,,,. � ,� M .� ,,,, S, � � �.a - la \� t Y �.r'ry � � E'. �,. � v „� s ���1, .,,� ,.,,m x „"�,. '., _ ,� w�,,r, tl „vk rv, v,i " +, ”, . 7,w',.P :...o , n n t ., w^ . , rt � r ... � M"W, � Cm., � ,.. ,r;'C. °I, �u.,�,^, 1".f.. 1 h„ �„� .. ..,, .A a,l r' a. : rv,yWv .., "�,, �,� :r !^I ,^*:��. w �°, „.,. r ,” •,, - •- {, 1 :('.i f.. .., �.,""' ; ,. wfi d 3Yi ..,." nt^�,,,, , .I �� . � I. � � � i. .: Yvu � "rv' k ., .� `M,, .,,' ti,i,� n .k ', , v . � " a ,u. d.. ,. „i .. wv yr ��'k ,,., �,: d. �W„ � i'. ,, a I' b''. r u, :i"','+1,4�rw + '.W,;,x. , q u�, k ,A +"I�t,w r >,,., • o �^' P$: a. �. Mr .�„M ��, .,', �. X �,;, � „M,,,, ,p„” .o ,, 441" _.."..:'. Mr\''�', � *, r ��n �„y�'I � „�!� � ' n,lt., �,, ,� � Y !�•r 'i� 3',,'.:�k", DEVICES FULL LOAD ; TOTAL Wire Resistance (R)( Device Load, Amps (I) u. Drop�(E i _ � _ �,- mA=; 1500; 14 24.00, (W Rift) (Total Cct Load) (E= I * R) E) 1500 ;Total K J Total _ _ __, , 0 00 '1.50 .�---�-_�- 0.00 ':Voltage OL Voltage24 z,..,,w 'Cq .,•o;Ya"IFr' ��k;'"n ° ,n^^'^"' �!�!�. .�::'� ^.�;w,t ,11 r "fix .. ,.",r.' r. �, !S", .�q� G" r ",,;��,� -. ,. .,. .,��'. ;..,r ,� '!,A..,. ,a,', f ".d.;,, .,IMS r„. 1 �:,� „„�r7 ,.»vM Y.. "„w”, � ���.,v____� 24.00 . # Md^�'.. n"�' �< z �? as >+;",+pr ., %jdw � a",m'''Ih"✓,, ,, .::' ° +,';�t aa^� ; �," • M A 'r�,Y 5, P.,� �,t{c ,',,', a` +�9 ,,k{ ,^a ,;,,., r. '.p�\ m�, 4 rw+ • ` .µ.. rr'�Xff G G" $p', .. �, �1.;. ', *,; ”'\�" .�'• �1� %:; .���, tl � M,� ,' �,�„ �, �: ,. II ,.;„,: v. ��,, ” �Y',r, 4^... .V 1 •���,, ,, f i,., v, m :r�� "�„r;. a ,. w„vR” . ' r� ,; , �'" .. .,•,,,f,M 6r,r ,,, { ,In; 'r.. ... 'd^y4, „ryf; ,~•'t �r a ,,,',, ,„?” i, ,Y, .,. rR+' ,,X";r rrby w.” e,v. -15001 14 �.__ _�.. ,,�, � ti � w } .�,,: �,PJ, Rx Nr d,+ - K M,d,& Y\ 4 ,\ro Jr 0 Y. '7,, i `,: ..�, �„ �- n f� @r���,I rt,d fio�„ k'i ."{„�i "i3'' .a`,. a 24.00; a,,rk.��. e,r '+.�, ., w” , c , c, Cu' �6tM# r. ^'„.,.. 1p +,�\y r bAi'ky,,, 1500 .Q0 1 60 0.00 DEVICESFULL LOAD I TOTAL mA= Total Total `Voltage - .. �L Vollge . ',.��"p.. d ",„ i,,�0.M,; �+'�,.� rfi ;a.: m,.wm,YM „Ir �n"m,'����, G #�',:�tlIIIIV 11 MB";�k Wire Resistance (R) Device Load, Amps (I) (Total Cct Load) { _. _____�. _ _ ._..��__� (E* 24 - E) Drop { E) .fr 24.00 Irtr ,dr;,ir a y Mi ,Y ° ,1. .; �}hyr��T �b'� N, Nm6J �m,,,w, p�M1l 'aha*;�.�a (,. �11 `k M ',;i �: r.- +yy' '��, ^,,, :.'M Wim' �,�)r a �:i,'�Ib�� ➢Po ° G�.il ;'�S)r, � "�:'. t d rM, ',; �.'. d'i "",. -� %a lypq�.' ., I,r . r(�'1 . :, MI a','w;. .3 rI ISOm' .. Jl�ro x �i"' r '"'�, ty rv4,,,, rr��bb S „! „ r ..: r r9 '�M#k��,,��� � �"y� K.�,>P e i V rW(,�'il�� �a Iy�,i Y. 0 :yC Y Ai ,. ,,,$�tlu'G w m d'rJ Yea>'?'4,, .,l\„M'i+:-,� '4'^�,a V'MY °'. "m,' r MI i„d lkdA '� '�$f `I �'j�'r4Y't'd' h... rlr I P .y �.,'���,Y ✓+�, ';1^, ,:w.e'"fi 41" = r'r;!',^M' '} x^. ,,. ■■ 4 t ..N �6,mM \vUTw^ ¢ i'yJe f','Vx'i,.' iiv'4u�i[i`PvY""Ydlf 1500. 14 24.00! (W 2 ) * (Rift) �* _. ....., (Total Cct Load) _ _ �_._. (EI*R).._ - ° 24 - Gpr: ,r. xrr + . _._. ,.i aw. /��� �""ti•�I;v,. i�•aF3dt �.'�'. x4dz 1500 DEVICES FULL LOAD TOTAL Total Wire Resistance (R) Total Device Load, Amps (I) mA= 0.00 1 50 Voltage Drop (E) .-.. EOL Voltage' 0.00 24.00 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS SYSTEM CALCULATIONS TO NEAREST EXISTING POWER SUPPLY (EXISTING BACK -OF - THE -HOUSE J -BOX) TO NEAREST EXISTING ,, • DATA LOOP S4-1 S4-2 30cd 15cd S4-3 15cd S4-5 15cd HT -R S4-6 15cd S4-7 15cd S4-8 15cd • S4-9 15cd S4-10 15cd S4-11 75cd S4-12 30cd S4-13 30cd FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. EOL S4 DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 0 ac 0 W z W Z co J W o J C'3 CC 273) � z o O Q2o C j w� o ww= W cn0� Q CO m Qlig 0 cc co CDo IJ 0 W F— >— Cl) 2 CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/03/ 16 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM 1.OB NUMBER:15148-1i % TO EXISTING BACK -OF -THE HOUSE JUNCTION BOX I I 7>- u, CU Q p, CU SL/ WA I I VALJ STCCL ROC A Ii n SLAT WAIL HS 72" r L WS 48" S4-2 15cd "1 L (f.) BULLETiN BOARD HALLWAY S4-4 1 5cd s—c, //, .4/ /477-77 S4-3 1 5cd S4-8 15c H.C. FIRM 1 04 IS V Wife Aard Agar Nir Arore/ I I-IHM G,41-6 1 5cd ✓ Agsprorhy ✓ A ....111 FTRM 15d 011 LOiSRii COAT, HANM BULLETIN BOARD BULLETIN BOARD 11 • ACCESSORY S4-10 15cd ------ POSi S W FETAL 01 IS 561W DISPLAY TABLE I • S4-12 30cd S4-9 1 5cd FIRM 03 HALLWAY .r ACCESSOR I 6 : I: I i-Lti I 66IN DISPLAY TABLE I a' CU 1W) POS 14 - Err - 66161 DISPLAY TABLE t • FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. OUTERWEAR GEAR M FIRE ALARM SYSTEM PLAN • • .••• • • • • • • I • 661W DISPLAY TABLE I a. 11°_i CEAR POLE S4-13 6EIN DiSPLAY TABLE I 11 \ i I I 1 I . \ • • s - ...t , j ----- ,_. II 56IN DISPLAY Tv.."-ILE 14 6.5 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m c: DESCRIPTION SHOP DRAWINGS DATE (0 to 0 C•I 0 2 <<<<< z cog WO'- --JO) OcD ° <z 20 I— < cri— U) = M W CD pr.c,2 2 ft: co 5 tig LLI LL. CO ‘CALE: 3/16" =1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/03/16 BACKROUND PLAN PROVIDED BY: 1.13B NUMBER: 151 SHEET ( \ FA -04 NO r A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to comme;-tcern of :acceptance Testingci- any Fire Alarm and D+;.ectic i Systems. Failure of test tt ill result in a Re-inspecdan Fee and termination of the testing I FIRE ALARM SYSTEM ADDITION TjJKWILA, WASHINGTON SHEET NUMBER SHEET TITLE FA -01 SYSTEM I \ FO MATION FA -02 TYPICAL WHI\G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SI\GLE LINE DIAGRAM FA -04 FRE ALA vl SYSTEv1 PLAN SHEET INDEX 3 Without Comments 0 As Noted in Rett 0 Per The Attached Letter These plans !}eery 1 eviewed by The Tukwila Fire C'(,: ention Bur ezu} .:ynforinance with current City '.;dards. Acce,oa:: ti.:,ubject' to errors and :missions which cin >;c: .3utrorize violations of adopted ?rdards aivr o,I-,,,;1_1.:'.:ts. The respons:hll!cy for the adequacy of dc;.sinn .':tally with the dc;s gner, to these drawings after this date will , ,,d _.::.:�cceotano and will require a resubmittal or , t] ; i =er.° subsequent approval. Final acceptance is suvfe�_ ,o Odd test and Inspection by The Tukwila Fire Prevention Sureau. Date: 1—?•61") So By: sl and z lit, No i. .F- of s' aY,B add ess for shut - flown or restoration approval. l. D U LE AND C O\ D U IT FILL C HAAT SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11 ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12 ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13 ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 1 ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15 PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16 WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17 ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19 THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 22. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 7 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER EX POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3—ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO—ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING ®D DUCT DETECTOR AD2—P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1—GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI—R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD DI FIRE ALARM HORN STROBE ZH—MC—CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR—MC—CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A -N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 171,275sf macys 4 LEVELS 250,407sf 00—� .�-. 6�fie3iG FC IIOX SHOP 3 050 dux MSC Caw x Rets= 2 TZ, RtRE RLSr. a':r=_4a uu s CLASSs Otte I I C. 2I r EDDIE BAUER #670 PAID JAN 19 2016 TUKWILA FIRE rt) 176 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C D P S S' V V I STROBE SYNC DATA LINE -ADDRESSABLE LOOP DEVICE POWER - 24VDC STROBE CIRCUIT - FEED STROBE CIRCUIT - RETURN SPEAKER CIRCUIT - FEED SPEAKER CIRCUIT - RETURN REMOTE INDICATION LIGHT TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) TWO #16 FPL/FPLR RED (JACKET) TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR #14 FPL/FPLR RED (JACKET) TWISTED PAIR #14 FPUFPLR RED (JACKET) TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11 ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12 ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13 ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 1 ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15 PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16 WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17 ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19 THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 22. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 7 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER EX POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3—ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO—ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING ®D DUCT DETECTOR AD2—P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1—GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI—R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD DI FIRE ALARM HORN STROBE ZH—MC—CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR—MC—CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A -N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 171,275sf macys 4 LEVELS 250,407sf 00—� .�-. 6�fie3iG FC IIOX SHOP 3 050 dux MSC Caw x Rets= 2 TZ, RtRE RLSr. a':r=_4a uu s CLASSs Otte I I C. 2I r EDDIE BAUER #670 PAID JAN 19 2016 TUKWILA FIRE rt) 176 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE t 0 Z coo O -� IZ i= Q °) w 2 < Q 2 co w W= W (n � 0CC'5-- 0wog Wwo cc N I: I— Z 0 �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 14/ 1 6 BACKROUND PLAN PROVIDED BY: SOB NUMBER:14381-1i WIRE DESIGNATION GENERAL NOTES SITE PLAN c� Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING 01 AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6011Z �j DEDICATED EMERGENCY 111 NOTE FOR ADODIONAL SPEC61CA1fcNS SEE PRGOUCT DOO11liNM110N. INTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC tgglim TO NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE MOI XLS CDNTRO. PANEL a+ O2 PREVIOUS ADDRESSABLE DEVICE 0 GRCOND 0 HTRI—R 0 0' 0 0 NOTE: FORADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) 00 00 a PAD -3 00 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 0 0 0 0 0 0 0 3.6k EOL (-) (+) (-) (+) 2 SPARE SPARE SPARE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) C WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIRWITH SHIELD #18 FPUFPIR RED (JACKET) *CONTACT RATDIGS: 4.0A 0 125VAC 4.OA 0 30%VC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. GROUND (-) 4 J HTRI—R o 0 O 0 0 5 72)' (+)> TO NEXT DEVICE OR STOP IF LAST DEVICE (-) _.> DRY CONTACTS TO VAV — FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL • POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY 0 HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TYPICAL TO NEXT DEVICE OR END OF LINE WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN TEMPERA RE: +32' F (0' C) TO 100 F (38' C) HUMIDITY: U-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR -* FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WM DUCT HOUSINGS AD -11P OR AD-11XPR DATA IN ( ) >- DATA IN (+) > REAR VIEW DB -11 STANDARD SMOKE DETECTOR BASE (-) (+) SMOKE DETECTOR WIRING DETAIL < 0 0 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX 11111w— JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT I 0 0 =Vol= TO NEXT DEVICE 00 CADDY BAR SMOKE/HEAT DETECTOR \ SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 0 z<aaa< z 0 -� o CC o Qz W 8¢ p QW �Z 00 W LLI LUQ 0 cc_� Q<0 W W o to LL I— -J SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 14/ 16 BACKROUND PLAN PROVIDED BY: \.OB NUMBER:14381-L) SHEET FA -02 Security Systems, Inc. All Rights Reserved J _ FIRE ALARM BOOSTER POWER SdPPLY SUPPLY BATTERY CALCULATION Alarm (mA) _ 01 *0 « 0 _ a fl Project:: EDDIE BAUER " & �V:Ntu� nem» ...�.,.,.aj n� . 'y _ Panel:. EXISTING PAD -3 BOOSTER Date: January 14, 2016 Module/Device POWER Qty Standby (mA) .r .� ._T,_.� _._ _. ZH-MC-CW @ 0cd 131 171I -MC -CW 75cdn . _.� x.222 . �_�,_._... til-IAC-CW..r@95cd .292 MC W ©15cd ; 641 Total Standby (mA) Total Alarm (mA) Power Module 1 • -30 30 30 30 A TOTAL FIRE ALARM POWER SUPPLY d .� � ,ar 30 30 B ! } y Po; ' { P,r, d @ 1 ;Auxiliary Device Current t 0 0 q } 0 C j Notification Appliance Load (Max. Total / mA) . 4 - 0 4403 1 ' 9 I _I_Tota!�A)= CALCU'_ATION } ____ -___- .._-____ 3O i Total(B)= 4433 __-......_.__ _._.-_..,,_...__ _______-._-------..____._._. 14 . D E F G Total current ratings of all devices in system (line A + line,E + line C) 30 4433 Total current ratings converted to amperes (line D x .001) 0.03 4.433 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 ELVolti e g Multiply lines E and F �. � Total Standby AH 0.72 ;. ... • ,: tw'T"IWW ...:.-:,a . �: ���,�,� ;°I, r,!i,iµv �� .ifl,A ,, ,��::',�„ p(� � 11ry„ _ ... r...,...,.,.<... ....ac. 1.... __.,.” w . ._ _ 1 H Alarm sounding period in hours (5 mins+ .0833 hours) �Ir; ,,., .: . t4W ',: ,yF r1 ,? \ w r ,m'' u„ ,,,,y::r 5 ,:,�1 :�'ui a ^ '''.`•„:,.., � � r,N .} _ t yn p' a � d `z a 'r< b�5';d V4 <W �$t'.r ek,',d,:Ar G ,, .R ���,+rr,:��'�y .,._....wac... 0.0833 I K Multiply lines E and H Total Alarm AH <i.J.�,Y�. .aa�i ' ' - - 1. <..wu.a...«rr... 71H -MC -CW @15cd 87; 0.3692689 Add lines G and I Total 4ta.ndby and Alarm AH 1.0892689 YZH-MC-CW 30cci. .131 ZH-MC-CW @75cd22_2; Multiply line J by 1.2 (20% extra insurance to meet desirn1 performance) 1.30712268 876 0 12-V DC BATTERY SIZE RECOMMENDE' (AMPERE -HOUR) 7 DEVICES Notification Appliance Circuit Detail PROJECT: EDDIE BAUER , Resistance TOTAL= 2.58 4403.00 0 Panel: EXISTING PAD -3 BOOSTER POWER SUPPLY ;Wire Date: 'January 1412016 CURRENT )...' .._, . -_•,- ::, 't_;, . �'...•......P«,r�k.N-'p,.f.� ..:,,.0 ....,.,, rll�^ v aY..r-.--..1.,ZH-MC-CW -- -; ____ �.-.1714, DEVICES _ _ --- _ 4141• 'uf.. d w^C.I""ro:::d,."....eI..� m. , ' k'M1 M1 rni.. L @l5cd 87'.. _ 01 *0 « 0 _ a fl � " & �V:Ntu� nem» ...�.,.,.aj n� . 'y _ 4 , c w� Ti ...uu.,...x>•....,r,...-.w...,....—_ f _" . j 1500 0.00 1.50 0,00 G'% _ .. ,.».,..�.._,�» -_.. w _._ _ - .�. _ 24.00 .r .� ._T,_.� _._ _. ZH-MC-CW @ 0cd 131 171I -MC -CW 75cdn . _.� x.222 . �_�,_._... til-IAC-CW..r@95cd .292 MC W ©15cd ; 641 , ._ . �._ �4 .. - 14 Zit -MC -CW ;15cd 69 ;0 ; TOTAL mA= i- 1500; ;Total Wire Resistance (R) �,� _ �;T (WL*2)*(R/ft) Notal ((E_ Total Device Load, Amps (I) Voltage Drop (E) w. R_... __ -__-._ ._..,_.._.,.... , .A EOL Voltage Cct Load) I. * R) _..... �4 d .� � ,ar 1 4 Y@'",.B+,4e,$1 t7 rp h @�,:, �:'.}, @iJY9; @ t".�„d x $ i y Po; ' { P,r, d @ 1 :•a ;�: ZH-MC-CW @15cd 87:y 0 _ _ DEVICES ZH-MVIC-CW @30cd 131 1711 -MC -CW @75cd 222; fl 0; ZZZZ-MC-C1PIW-9cd 292:: iZR-MC-_W_@15cd 64 .. -MC-CW @l5cdt• — 69 ,0 ; TOTAL mA=1 1500 fl 14 . 24.00 (WL*2,)*M. j Notal Cct Load) _ _ _ : ;(E= 1 * R) 1500 0.00 1.50 0.00 Total Wire Resistance (R ) j Total Device Load, Amps (I) . jV oltage Drop (E) ; i . ELVolti e g �. � � `■ �+ i/W, ;. ... • ,: tw'T"IWW ...:.-:,a . �: ���,�,� ;°I, r,!i,iµv �� .ifl,A ,, ,��::',�„ p(� � 11ry„ _ ... r...,...,.,.<... ....ac. 1.... __.,.” w . ._ _ 1 .-. ' : _; 9 v” Pr -^b , � �: ?: '� `I1� � . a1 :L,,^ , ,: !� - "q, Cr :�, ✓+ ", >vt-Xa "v r,b v n,,, t,,,,, '..a,a {{,,q�pp � `, rk 'r'+ { .ii, a., ,,, ,I„ ,ti .... ,.., . ,,. _ a.: _.: �... . � :� t,y w r ^ .,:, �.. XI Pby,,'n � ...: �, �, .v „aN..,.r :: `., �aq, t ,'rt,,,, :, . "f / , k,,,ti, rn,V ",, r , � �Ir; ,,., .: . t4W ',: ,yF r1 ,? \ w r ,m'' u„ ,,,,y::r 5 ,:,�1 :�'ui a ^ '''.`•„:,.., � � r,N .} _ t yn p' a � d `z a 'r< b�5';d V4 <W �$t'.r ek,',d,:Ar G ,, .R ���,+rr,:��'�y .,._....wac... :'@E�"!, ','fir,+ m 'd:n;'�, .r KK, .,, Pt, n * �` ,µal:p f/ -to{{�°PPpp °✓, � ... .:.:. A" �,X�,��M '� „S^ .,F ., v., :�,,,: .:u,,,,� � :::„ , � �f � �_s., � ".�,, m 4r,'n,,i'f. > ��r v �,:C.. "1 W.''i . �a- AFY�i;+, :s`@,H r,4,,,;,`� a..__,«y.a_.r. ¢ ? qi ..';" .d'i,5,:, • ..v�}„s�,,. ... M%��k,i t " ^' I{ � �:, � �:.:: :�',. :^,., �I�� C „�,.,�. 'a :,� r„ I�. !, :: .ql,,,+ w. ," ."I:,,m„�,,,,, �::^ �: y; � t ;KK � , ..b ":I,. ,,r m V�.” ':'•: <i.J.�,Y�. .aa�i ' ' - - 1. <..wu.a...«rr... 71H -MC -CW @15cd 87; 174 j ..,__..__........aw:a �.....+s+-c.�s ...r✓x..,.✓u_. .w.w.«.,..t .aa.. � n ...._ YZH-MC-CW 30cci. .131 ZH-MC-CW @75cd22_2; 222; wCW tit cP._ d �. r «, 292 —2W -Md: ZR -MC -W @15cd i 64; 876 0 DEVICES -MC-CW @l5cd 69 ' ! 7 i TOTAL mA=. 1403 ] 14 247 22.211 1403 •Total Wire Resistance (R) Total Device Load, Amps (I) ;Voltage Drop ( E) j j (WL (Total ; (E= 24 * 2 * (R/ft) € 1.27 Cctad} Lv I * R) — E) , . ; " ` 1. ._0 40 1.79 22.21 EOL Voltage - m 7' y . 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 SYSTEM CALCULATIONS BPS • (BACK -OF -THE -HOUSE) S3-1 30cd S3-2 75cd S3-3 15cd S3-4 95cd S3-5 95cd S3-6 S3-7 95cd 15cd EOL S3 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE Z 0 J ix 0 w z w Z co Opo C� W c mo o UJ Q W Z LL! cf) (¢) 2t!) a ac o ; z D Q 0 0E. I- 0 W F - ' ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 14/ 16 BACKROUND PLAN PROVIDED BY SINGLE LINE DIAGRAM \ 0B NUMBER: 14381-1} SHEET FA -03 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved V MB MENIMMIIMEME ME MEIMEIMMIEMMI s, r e II • NEI S3-3 15cd D • 4 2C 0-" v (1Th 24,-0 /I / 2L,U„ X i , L x -x IMMEEMEIMMIEM 1-1 • VOID I� A; n E v Li 1 04'^"w- EOL S3 S3-7 EDDIE RCP, SUITT #2-1 S3-4 95cd a ® a ®m_s all IIIIIIIIMEINEENIE S— L TO EXISTING BOOSTER POWER SUPPLY • S S3-5 95cd x S3-6 95cd ® IMMEIMMEMEMs ® _ ®oo AREAF+ 128 -rE EASEE EINE a ▪ e ▪ - FIRE ALARM SYSTEM PLAN / I I i i 0" I — EASE A i` CL VOL7 }sE U (3-3) LEASE LEASE 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: C0 m 0 DESCRIPTION SHOP DRAWINGS DATE to N, 0 2 as<aa J /SCALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 01 / 14/ 16 BACKROUND PLAN PROVIDED BY: JOB NUMBER:14381-1_1 SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved \ J FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON 4.1 SHEET NU vi 3E SHEET TITLE FA -01 SYSTEM INFO MATIO\ FA -02 TYPICAL WRING A\ D N OU\TING DETAILS FA -03 SYSTEM CALCULATIONS A\D SINGLE LIN E D IAG RAN FA -04 FRE ALA SYSTEM PLAN SHEET INDEX 0 0 j. WiLhoUt Comments As t'` 1.+te.'.i in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau fori;,cnfOr,rkance with current City standards. Accept_anC is subject to error; and omissions which do not autnoriZe violations of adopted standards and ordina: s. The responsibility for the adequacy of design c -a is totally with the designer. Additions, deletiot is or v,siuns to these drawings after this date will void till' acceptance and will require a resubmittal of reviseu drawings for subsequent approval. . Final acceptance is subject to held test and inspection by The Tukwila Fire Prevention Bureau. Date: o'" 9- /)- By: NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. TIJKWIiA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. / a- - F -/71 and exact address for shut U ern ArlefflT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPUFPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPUFPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPUFPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPUFPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1 /8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.=.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHA_L BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE,. OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX EX EX EX 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1 G RING CEILING ® D DUCT DETECTOR AD2-P W/ SIEMENS HFP-1 1 DET. EXISTING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD DI FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2" EXTN FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F. B.O. FURNISHED BY OTHERS N/A N/A N/A N /A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A NI/A GREEN BLUE AS BUILT REMOVE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND N/A N/A N/A N/A 743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE N co 0 2 ««< ALDO #670 m ervyers NORDSTROM 5 LEVELS 17,,275Cf ,./ES eFt21E i140ER ?0A FTS CAVERA JCPenney EAGD e ,ESS MACE MASviGICN '9Er:2S OFTcsscw S MC'I.ER-an MATE-, ,1. PAS, r.A SEARS Fox r.crrar RESTAL:AMT 710 PATO ATO Z cco c.--2 Z Q w W ZZ co CC Q W -(o I!L F- Z 0 1-1 0 W l•- (.1) (1/1) r SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 05/15/12 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved NUMBER: 55486 J SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ DEDICATED EMERGENCY NOTE: FOR 1CCflKNAL SPEEDTAIIONS SEE PRODUCT DOCUMENTATION. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 301.0C PEEZIE FRO1 GklJ A D TI] NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE MON XLS CONTROL PANEL (I' OR PREVIOUS ADDRESSABLE DEVICE - 0 II SL GROUI J 0 0 HTRI—R 0 e11 EOT ®A O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 PAD -3 oo INPUT INPUT TROUBLE NACI NAC2 NAC3 N1C4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 0 0 2 2 0 6k EOL (-) (+) (-) (+) 2 SPARE 2 SPARE 2 SPARE ( FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) WIRE DESIGNATION. NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPIJFPLR RED (JACKET) 'CONTACT RAIINOS 4.0A 0 125VAC 4.OA 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O C> Fel O I ®, I HTRI—R I ; J � t- 0 GROUND (+)) TO NEXT DEVICE OR (-) )' STOP IF LAST DEVICE DRY CONTACTS TO VAV _. FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY U U HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERAllViE: +32'F (0' C) TO 100'F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —` -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE rDATA IN(-)> Sl DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION HATH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL 0 0 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX EaY 7 \k. JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT /�— TO NEXT DEVICE ---CADDY BAR SMOKE/HEAT DETECTOR ----- SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL FAX (206) 628-4990 TEL. (206) 622-654.5 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE N Z to (0 0 2aaaaa Z coco O J c; -Z WO u.w z z c(/) O c= ©C cc0 W cc co D L1_ E— (SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 05/15/12 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 55486 SHEET FA -02 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved ALD , EXISTING SIEMENS ' Signal Extender Panel Battery LoadCalculations DESCRIPTION SHOP DRAWINGS Current Load: = ' IStandby: ' Z �J ' a") 2 <<<<< Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -CW ©15CD 9 0.069 SET -MC -CW ©30CD 12 0.111 SET -MC -CW ©75CD 5 0.2 SET -MC -CW @95CD 7 0.264 1.848 ZR -MC -CW ©15CD 13 0.069 ZR -MC -CW ©30CD 6 0.111 0.666 0.03 Amps 2.544 Amps Standby Current Load: 0.03 Amps For 24. Hours = 0.720 Amp -hours Alarm Current Load: 2.544 Amps For 5 Minutes 0.214 Amp -hours 25% Derating = 1.167 Amp -hours Total System Current Load: 1.167 Amp -hours Battery Pair to be Used 12VDC 7.2AH EXISTING FA JUNCTION BOX PROJECT: ALDO Panel: EXISTING PAD -3 BPS :Wire Resistance 2.58 Date: August 8, 2012 j CURRENT TOTAL= 1893.00 Notification Appliance Circuit Detail .... ., 2 SET -MG -:::11::::.c . . 111 . , - ' 222 SET -MC -CW @15cd 69 01 .......______ 1 1SET-MC-CW ©75cd 2001 200I 1 SET -MC -CW ,@95cd. . 264 . ' 264 1 3 iZR-MC-CW ©15cd 691 _ 2071 ZR -MC -CW @30cd .. -111 ' - . 0 . . DEVICES 17 TOTAL mA=1 893 14 328 SYSTEM CALCULATIONS cDEx EX S1-1 30cd V-1 I HT -R EX TSM EX EX EX s,v,v s,v,v s,v,v S1-2 15cd S1-3 15cd EX S,V,V Total Wire Resistance ( R ) Total Device Load, Amps (I) 22.491_ __ 8931 . . 67ci Load) 0 89 ,Voltage Drop ( E ) (E= I * R) 1.51 EOL Voltage - ' 24 - E 22.49 EX S,V,V V S,V,V EX S1-4 30cd V-2 S1-5 15cd S1-6 75cd V-3 S1-7 95cd V-4 EOL Si 1743 ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-651+5 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE Z �J ' a") 2 <<<<< cr 0 w z w co -J z co 0 E z mz o cf) z o 0 11-1(-9 0 zz uff ci) Z 0 < 2 0 < W CC D 17- 0 LLI C/) >0 - 'ALE: NOT TO SCALE DRAWN BY: O. GARCIA DESIGNED BY: R. VEZZANI DATE:05/15/12 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM \JOB NUMBER: 55486 SHEET FA -03 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved L(E) MALL CONCOURSE 28'-g"" TENANT LEASE WE K> 02 (E) ADJACENT TENANT SPACE - NO WORK TI -HS AREA TENANT LEASE LINE NEW CONSTRUCTION , NO WORK TI -115 AREA Co ii L ±1 STORAGE AREA LEASE LINE EOL S1 S1-7 95cd V-4 VACANT TENANT RETAIL SPACE 100 EX 95cd A L TENANT SPACE = NO WORK T?'IS AREA S,V,V S,V,V ST 00M I -5 15cd 4 4 • Nnipo 8 S1-6 75cd V-3 EX 75cd EX®o TENANT LEASE LINE 4E) ADJACENT TENANT SPACE - NO WORK TRIS AREA/ Co ♦ AI .. S,V,V 22'-6" V • m S1-4 30cd V-2 S,V,V S,V,V LANDLORD S TORAGE AREA 101 [ EX2 V-1 EX HT -R SI-3XXEx I 15cd S,V,V A n S,V,V S1-2 15cd v. EXIT EXISTING FA JUNCTION BOX TENANT LEASE LINE O �©USS CO - /5�,pK {� -x\-115 ����7 \\V)Wo /NO WORK TRIS FIRE ALARM SYSTEM PLAN FLAG NOTES: EXISTING SPEAKER/STROBE TO BE REMOVED. EXISTING SPEAKER/STROBE TO BE RELOCATED. cc el; 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS W N 1— Q 00 (D 0 0 co UJ oco O z (O � W w w z o 1 wI Cr Ir Co LL. W [1: 4-CALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 05/15/12 BACKROUND PLAN PROVIDED BY: J213 NUMBER: 55486 SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Ri hts Reserved \ .j � SII• 'S FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUIV 3ER SHEET TITLE FA -01 SYSTE INFO MATI O\ FA -02 TYPICAL WIRI \G AND MOUNTING DETAILS FA -03 SYSTEIv CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FRE ALARM SYSTEM PLAN SHEET INDEX pi Without Comments ❑ As N6 -.ed in Red ❑ Per The Letter These plans have been re'-iew u ;v The Tukwila Fire Prevention Burebu ,..161 current City standards. Acce p::er:c I. :i::Tors and omissions which cd of adopted standards anr:: t_ 1 n=r1<_ .. i ; ,..;.: ;,tiro/ for the adequacy of design che. de3igner. Additions, deletions or revisOns to `hese drawings after this date will void this e; car!ce '.':d w l require a resubmittal of revised drawings suoseci-ent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date:1-1)- - I Y By: Ali\ W SCHEISP3TEn.V NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing.. TUKWILA FIRE DEPARTMENT Pease call 206-575-4407 and give this Fire Permit No. and exact address for shut - on M -D U IT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT- FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 1 1 1 2 7 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD ❑a FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING )) FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F. B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND I 1, NORDSTROM 3 LEVELS 5 171,275sf t1CTORIAS SECRET P� « aP,�,& ETs. macys 4 LEVELS 250,407sf 3LS£P. i cc. Whai I I VANS SHOES #670 15.f, TCKr3 j krn Pf_iil PAID FEB 22 2012 TUKWILA FIRE W 0' FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS w r- 02/17/12 0 2 a<CCa 2 4CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/ 17/ 12 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved .0B NUMBER: 55416 FA -01 SHEET THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60H2 �I DEDICATED EMERGENCY 111 NOTE FOR ADORltNAL SPEfl1CA1IONS SEE PROOUCT DOCUMENTATION. *CONTACT RA11NGS 4.0A 0 125VAC 4.OA 0 30VDC TO NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE s - FROM XLS CONTROL PANEL (I OR PREVIOUS ADDRESSABLE DEVICE D 0 GROUND I L 0 0 HTRI—R 0 O 0 O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) ° ORO N L a 0:1 110 11 II 0 PAD -3 oo[1 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - S 0 .1.Q-11-Q111s211-21[-Qtca 3.6k EOL (-) (+) (-) (+) 2 SPARE SPARE (2 SPARE (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLORCODE TWISTED PAIR WITH SHIELD #18 FPLIFPLR RED (JACKET) 'CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. D 0 F7-10 00 GROUND g HTRI—R 1 0 DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. 0 (+)> TO NEXT DEVICE OR (-) (-) STOP IF LAST DEVICE DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL + `J HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY + U HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERATURE: +32' F 0' C TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR — DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL o0 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE //- STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT JUNCTI❑N BOX MOUNTED ON CEILING FLEX 00 I TO NEXT DEVICE CADDY BAR I SMOKE/HEAT DETECTOR \\— SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved c0 0' O I- z_ (J) LU I— F-- LU U) F- O U) U) r- FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: _I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE c\1 sc t` N 0 2 aaaaa Z co co Q J� C11 <O) w c 2z O< cco = w zZ Ci) ZLI.. = w 0 W cc co LL �-- SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/17/12 BACKROUND PLAN PROVIDED BY: J.0B NUMBER: 55416 SHEET FA -02 , , a, ' DESCRIPTION SHOP DRAWINGS Current Load: DATE Standby: Alarm: ' ' , ' Z N a Device Type Qty Amps Total Amps Total Amps HFP-11 1 0.0022 0.0022 0.0023 0.002 AD2-P 1 0.0635 0.0635 0.064 0.064 0.030 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0875 al -MC -CW ©30CD 2 0.131 714 -MC -CW ©75CD 3 0.222 ZH-MC-CW ©95CD 0.0731 Amps 0.106 Amps , , a, , DESCRIPTION SHOP DRAWINGS DATE Y Sndby, ' ' , ' Z N a 2 <<<<< Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 714 -MC -CW ©15CD 1 0.0875 al -MC -CW ©30CD 2 0.131 714 -MC -CW ©75CD 3 0.222 ZH-MC-CW ©95CD 1 0.292 0.292 ZH-HMC-CW ©115CD 0.371 IZR-MC-CW ©15CD 3 0.069 0.207 714 C -W ©15CD 0.064 0.03 Amps 0.529 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.529 Amps For 5 Minutes= 0.044 Amp -hours 25% Derating= 0.956 Amp -hours Total System Current Load: 0.956 Amp -hours Battery Pair to beUd. 12VDC Amp -hours 7.2AH Notification Appliance Circuit Detail PROJECT:IVANS SHOES Panel: !PAD -3 BPS Date: February 20, 2012 'Wire Resistance 2.58 CURRENT TOTAL=11514.00 1 ZH-MC-CW @15cd j_ 87 87 2 ZH-MC-CW 430cti 131 262 3 1ZH -IVIC-CW @75cd 222j 666 111 -MC -C14 @95cd — 292 292 IZH-MC-CW 0.115cd 371 0 3 ZR -MC -CW @l5cd 69 207 DEVICES 110 TOTAL mA= 1514 (Total Wire Resistance ( R ) Total Device Load, Amps (1) . Voltage Drop ( E ) EOL Voltage 14 166 • • i( WL* 2 )* (Rift) I 0.86 (Total Cct Load) 1.51 1.30 24 E) 22.70 I(E= * R) 2C TO NEAREST EXISTING? SIGNALING CIRCUIT 120VACI DEDICATED (BY OTHERS) ( TO NEAREST EXISTING DATA LOOP SYSTEM CALCULATIONS S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 S1-8 S1-9 S1-10 15cd 75cd 95cd 30cd 30cd 15cd 15cd 15cd 75cd 75cd 13LHT-R4 D,I I HT -R1 21 TSM I FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110VAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME EOL ROOM/AREA AS THE PAD -3. Si DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 om DESCRIPTION SHOP DRAWINGS DATE Z Z N a 2 <<<<< cc 0 z co z co Z Cf) < z 07-A- 20 ‘41 0 < 1190 1- 1- Z Z Z Cis) Ill 4=C Cl) z 0 C.)U) Cf) < 2 f_ Z CC citt 0 ><° w ciz). cc (oLL In 0 47t-1 0 LLI F— Cl) >- C/) 4-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:02/17/12 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM JOB NUMBER: 55416 I. SHEET FA -03 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved r I ►; n! I- ELI- CIF- nr-- I Nr, KY „ ! SYh•MPOL MANUEACTJPE ; / DESCRIPTION A ( f, PENDANT MOUNTED HIGH HID BAY FIXTURE AT XX'—X" A.F.F. B2 RECESSED. ADJUSTABLE COMPARTMENTAL LIGHT FIXTURE HOUSING I \\ BJ CONTECH ;iRAN15038—X3—B-21L BL RECESSED, ADJUSTABLE COMPARTMENTAL LIGHT FIXTURE HOUSING � A,71-7; :J • 2 aaa<a STOCK ROOM: CON—TECH fRL38-21LBL;' 6" RECESSED DOWN LIGHT WITH 21 WATT LABEL. SPECULAR REFLECTOR & WHITE TRIM NO CEILING. (OPEN TO DECK ABOVE) THE TENANT'S G.C. SHALL PREPARE THE CEILING AREA TO BE EXPOSED. RUN ALL CONDUIT, PIPING, DUCTWORK, ETC PARALLEL AND PERPENDICULAR TO THE DEMISING WALLS. REMOVE ANY UNUSED OR ABANDONED EQUIPMENT OR PREVIOUS CONSTRUCTION. THE STOCKROOM AREAS ARE TO REMAIN UNFINISHED ONCE EXPOSED. SILVER LIGHT TRACK _ENG , PER PLAN ( D2,4,6,8,12 E �� DECORATIVE PENDANT LIGHT F WITH SURFACE MOUNT SATIN NICKEL FINISH CANOPY ( 2 LAYERS 5/8" TYPE "X" GYP. BD. EACH SIDE OF 3-5/8" X 20ga. METAL STUD FRAMING. SEE DETAIL E/A6. TAPE, SAND SMOOTH, PREPARE FOR PAINT FINISH. EF I.`• RECESSED EXHAUST FAN — SEE MECHANICAL SHEETS F U CON—TECH LIGHTING fCTL838/2—U PAR38 ADJUSTABLE TRACK FIXTURE WITH BLACK FINISH. H4 4' FLUORESCENT OPEN STRIP LIGHT SUSPENDED AT 14' A.F.F. UNLESS NOTED OTHERWISE I I H8 8' FLUORESCENT OPEN STRIP LIGHT SUSPENDED AT 14' A.F.F. UNLESS NOTED OTHERWISE 4' OPEN STRIP LIGHT MOUNTED TO SUSPENDED CEILING GRID I i I I WALL MOUNTED FLUORESCENT FIXTURE MOUNTED OVER LAVATORY K I ! ! I TRACK SECTION WITH NATURAL ALUMINUM FINISH. LENGTH AS DESIGNATED. LE,4,6,8,12 SURFACE MOUNTED LED ILL JMINATED EXIT SIGN -12 _ X' SURFACE MOUNTED EDGE .. i EX:T SIGN WITH UNIVERSAL MOUNTING CANOPY SURFACE MOUNTED EMERGENCY LIGHTING UNIT WITH SEALED BATTER BACK—UP S I SPEAKER ABOVE PAINT LINE FURNISHED AND INSTALLED BY OWNERS VENDOR (TYP.) 0.0 TO COORDINATE LARGE CEILING MTD. S!UPP'_ AIR DIFFUSER. SEE MECHANICAL PLAN FOR EXACT SIZE. ®i SMALL CEILING MTD. SUPPLY AIR DIFFUSER. SEE MECHANICAL PLAN FOR EXACT SIZE. ! ! I! 1 RETURN AIR GRILLE. SEE MECHANICAL PLAN. I I SMOKE EXHAUST GRILLE. SEE MECHANICAL PLAN. Z. / NOTE: SEE SHEET E3 FOR COMPLETE LICHT 1 FIXTURE SCHEDULE I '(-) nr-- I \I' Impl-- c SALES AREA: DESCRIPTION SHOP DRAWINGS NO CEILING. (OPEN TO DECK ABOVE) THE TENANT'S G.C. SHALL PREPARE THE ; CEILING AREA TO BE EXPOSED. RUN ALL CONDUIT, PIPING, DUCTWORK, ETC PARALLEL AND PERPENDICULAR TO THE DEMISING WALLS. REMOVE ANY UNUSED OR ABANDONED EQUIPMENT OR PREVIOUS CONSTRUCTION. IN SALES AREA ONLY PREPARE ALL SURFACES ABOVE 12'-0" TO BE PAINTED INCLUDING DECK, STRUCTURE, EQUIPMENT, PIPES, DUCTWORK, ETC. MASK OFF ANY IDENTIFICATION LABELS ON ANY MALL OR TENANT UTILITIES OR EQUIPMENT BEFORE PAINTING THEN REMOVE LABELS BEFORE TURNOVER. COORDINATE WITH THE CENTER MANAGEMENT ANY UTILITIES (SUCH AS LIFE SAFETY LINES R DEVICES) THAT ARE NOT ALLOWED TO BE PAINTED. USE COMMON SENSE BEFORE PAINTING. I \\ GYP. BD CEILINGS: � 5/8" TYPE 'X' GYP. BD (AT HEIGHT PER PLAN) ON 3 5/8" x 20ga. METAL STUD FRAMING (PER DETAILS) TAPE, SPACKLE & SAND SURFACE. PREPARE FOR PAINT OR OTHER FINISH PER PLANS. 2 aaa<a STOCK ROOM: ! I NO CEILING. (OPEN TO DECK ABOVE) THE TENANT'S G.C. SHALL PREPARE THE CEILING AREA TO BE EXPOSED. RUN ALL CONDUIT, PIPING, DUCTWORK, ETC PARALLEL AND PERPENDICULAR TO THE DEMISING WALLS. REMOVE ANY UNUSED OR ABANDONED EQUIPMENT OR PREVIOUS CONSTRUCTION. THE STOCKROOM AREAS ARE TO REMAIN UNFINISHED ONCE EXPOSED. REAR VESTIBULE (2 -HR RATED): 1 2 LAYERS 5/8" TYPE "X" GYP. BD. EACH SIDE OF 3-5/8" X 20ga. METAL STUD FRAMING. SEE DETAIL E/A6. TAPE, SAND SMOOTH, PREPARE FOR PAINT FINISH. ILLUMINATED EXIT SIGN WITH BATTERY BACK HP LUX BEAM TO BE MOUNTED AT 12'-0" A.F.F. COORDINATE WITH VANS PROJECT MANAGER BEFORE INSTALLING. CL -i OPEN TO DECK ABOVE — PAINT OPEN TO S1 -EQ CL -2 10'-0" A.F.F. PAINTED GYP. BD. , CL -2113'-5" A.F. PAINTED GYP. BD. • ;_—STOREFRONT SIGN FRAME. SEE STOREFRONT ELEVATION. \\ \ \`�, \ V (i0-0 A.F F. 10'-0" A.F. it TO NEAREST D EXISTING DATA LOOP TO NEAREST 2C EXISTING 2 6 SIGNALING CIRCUIT L UX BEAM TO BE MGUNTED AT. 12'-0" A.F.F. COORDINATE WITH VANS PROJECT MANAGER BEFORE iNSTALLING. '—ICL -1 OPEN OPEN TO DECK ABOVE — PAINT FIRE ALARM SYSTEM PLAN 3" FIRE SPRINKLER MAIN 13'-11" A.F.F. / ,-ICL-3I OPEN /ABOVE NO OPEN TO DECK / PAINT N 1 // -5" A.F. FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. JI j " S1t4 // 30cd 0 m CL -2 .!0 O A.F.F. PAINTED GYP. BD. TO S1-9 CL -2 PAINTED GYP. BD. A.F .F. S1-2 75cd EXIST. GYP. BD. CEILING, PAINT. 3" FIRE SPRINKLER MAIN 13'-11" A.F.F. • LINE OF COMPRESSOR LOCATED ELSEWHERE, SEE Mi: FIRE ALARM SYSTEM PLAN (CON'T) OPEN OPEN TO DECK ABOVE NO PAINT Iw z J z U F - Q r0 CO 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m D DESCRIPTION SHOP DRAWINGS I \\ 02/17/12 2 aaa<a \\ \ \`�, \ V (i0-0 A.F F. 10'-0" A.F. it TO NEAREST D EXISTING DATA LOOP TO NEAREST 2C EXISTING 2 6 SIGNALING CIRCUIT L UX BEAM TO BE MGUNTED AT. 12'-0" A.F.F. COORDINATE WITH VANS PROJECT MANAGER BEFORE iNSTALLING. '—ICL -1 OPEN OPEN TO DECK ABOVE — PAINT FIRE ALARM SYSTEM PLAN 3" FIRE SPRINKLER MAIN 13'-11" A.F.F. / ,-ICL-3I OPEN /ABOVE NO OPEN TO DECK / PAINT N 1 // -5" A.F. FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. JI j " S1t4 // 30cd 0 m CL -2 .!0 O A.F.F. PAINTED GYP. BD. TO S1-9 CL -2 PAINTED GYP. BD. A.F .F. S1-2 75cd EXIST. GYP. BD. CEILING, PAINT. 3" FIRE SPRINKLER MAIN 13'-11" A.F.F. • LINE OF COMPRESSOR LOCATED ELSEWHERE, SEE Mi: FIRE ALARM SYSTEM PLAN (CON'T) OPEN OPEN TO DECK ABOVE NO PAINT Iw z J z U F - Q r0 CO 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m D DESCRIPTION SHOP DRAWINGS DATE 02/17/12 2 aaa<a Z co OJT 17-7 c z 0 w "< w 0 Z zz CD 2 Z ti - O W LL cc �I— �CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/17/12 BACKROUND PLAN PROVIDED BY: 1.0B NUMBER: 55416 J Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved \ SHEET FA -04 , O Without Comments o As Noted in Red IC Per The Attached Letter • The plans have been reviewed by The Tukwila Fire r,wention Bureau for conformance with current City ndards. Accept aoce is subject to errors and oi-ii;sions which do not authorize violations of adopted :::i.tdards and or .rices. The responsibility for the • ,1decivacy of design totally with the designer. • Additions, deletion.y. .-,Visions to these drawings after • this date will void ':.rr• (.-:(..:eotance and will require a resubmittal of rvseddrawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prtlentlo:ureau. Date:_2- -2 (0-11p_ay: C 1 -:1D7 and f'Q c-TiTR No. - 3)-- • • and a for chut- c:iown or rastaifdan zpprovL CHAIN HUNG FLUORESCENT STRIP LIGHTING MOUNT I 3'-0" ± A.F.F. VERIFY HEIGHT WITH DUCTWORK - 5LI3PNDQ FROM STRU DOVE (TYP.) STO9KROOM l0 ST UCTURE PEN I * JLJLJ 7'-3" 94.-0" FlexHead Sprinkler Drop . Cofrugated Stainless steel hose with stainless steel brai available in 2', 3',4',5 & 6' legnths . • . - . . • Multi -Port Bracket - Adjustable Hub FLEYBEAD INOUSIRIEVVF . • • • F.10xhebd -bbmniexcial Ciling Unit T -Bar Ceiling Installation Model #2024,036,2048,060,2072 I '-0" r\i• LINEAR FEET OF TRACK 5TRUCT. OPEN I <I- <I • < STRUCT. [OPEN MN, •••••••••• 101•11=110•111, 11110 ••••IMINNO I OPEN] 7 9/ il17-71/&/ HALLWAY 08 STRUCTURE OPEN V VV. ri 0 / aa # z II 41 VV • _ . GYP. BD. ✓ -O" SHOE STORAGE ok.5 GYP. BD. ✓ -O! •VV• VV vv, LQ I L VV VV V\7 .7— : - TRACK WITH TRACK . HEADS - MOUNT . TRACK TO AT -. • I 2'-0"± A.F.F. VERIFY HEIGHT 'WITH DUCTWORK • SUSPEND. FROM STRUCTURE AND -LOCATED AS SHOWN A • #1 A 1 A • FTRM HALLWAY. 02 STRUCTURE • : OPEN ani • • A • A A A •• • • r •1 - I I I I .1 . . RETAIL I oi STRUCT1.1 OPEN ' • : I U • UV' 4a '64a • aa V 011••••••••• •••••••••• .011011••••1111; U IMI/01•111 0 aa.• aa • ••111111111••••• ••••1•111114 V. 0•111•00•111. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAN/ C-CLAPP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING • • .... ••• STEEL JOIST/TRUSS HANGER DETAIL NTS G'V VV ,n,11 • LL 1•1•1•111111•110 IMP • L4. .• 12'-Q" • d -tu • b . o ARAKAWA CRI3 kAft:AriAerip .: - . • TO SOFFIT, 13IACK (F.O.I.C.) ;.• • • - IL.: • MOUNT PER MANUFACTURE'S -; itl -• • - . SPECIFICATIONS . - ' • • • DRAKE METAL I 2%-0'. RAKE METAL-. 12'-0" 0 TmOouSNOTFFPIET ARAKAWA CRP) RAIL ATTACHED. 13MLAANCUICF(ArCT.CIULREC.S) tu. 0 SPECIFICATIONS ••.• . , .- • • • • . 4: ta mmmmmmmmmm -a *LOT CEERTWI FIRE PROTECTION SPROAKLER SYSTEMS John J. Abel 9760 -0591 -Ce . Level 3 • , prot, , .• - Inm• ' l: ""11- -411 AIL 111. ••• REFLECTED CEILING PLAN w TRUE NORTH PLAN NORTH • LINEAR FEET OF TRACK Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 1— Add Globe Model GL5661 Standard Response 155° Brass Upd Y2 x o E — Existing no change O 4— Add Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x A7Ze 11,4) ike TENANT LOCATION MAP SPACE #0212 Lever! ate MALL KEY MAP ars - • CROWN FIRE PROTECTION INCORPORATED " P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Eddie Bauer • 670 Southcenter-B-1-vd Space 212 Tukwila, WA • PAID FEB 17 2f116 TUKWILA FIRE .12,975/ 7oz2— DATE: 2- g. DRAWN: (AT - SCALE: 3/1(o -Without Comments As Notes i,te.: Per The Attaci '.. atter ' e plans have.t)eer reviewed by The Tukwila Fire -'ention Sure -cu _,1iformance current City .;.Dards. ,L subject to errors and ;:;.,ions tit+?? r` :i tnorize violations of adopted • ;:yards anc The responsibility for the .-quacy o: :. i-; lot&l:y with the designer. .rt?ns, de{et;i;. .,Dior;; to these drawings after s date will void r .. .;,.ptance and will require a ( ;ubmittai of , .•;.: a sings for subsecluent•approval. l nnl acceptance +.o rleld test and inspection by Tukwila Fire " :=, 3r,,.n Bureau. Date:1—:1S-1So €3v: TUKWILA FIRE DEPARTMENT c- ;i 206-575- ' 07 cad Give Vii':{ Fire w Per ii 2 3L No. _/Co -S -Q02 • EXISTING EXTERIOR SIDEWALK EXIT # 2 (1) @ 36" CLEAR 180 OCCUPANTS 2 SPACES = 90 OCCUPANTS PER SPACE ord o►. d� w EXIT6Qi iu O� G1- N EXIS 1 -HOUR RAT T NANT DEMIING WALL TO REM , N n► U 4. N 0 Qa a 0a, EX T96 OCC. OR 01 o p' 0 Q, contractor shall patch and -epair existing wall to maintain 1 hour rating Ock OR OR ►,1 R 1 PR 30SF-= 12 64 O� h OR 01. THIS P RMIT SET DELINEATES THE NDLORD SCOPE OF WORK ONLY. FULL TENANT IMPRO EMENT DRAWINGS WIL BE SUBMITTED UNDER SEPARATE PERMi THERE WILL BE NO (DfN OCCUPANCY UNDER THIS PERMIT O(z Op. 1- \14>___ • EXIT # 1 (1) @ 72" CLEAR 0 OCCUPANTS BY TENANT Of QR SCALE: 1/8" = 1'-0" MIN Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 11- Add Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 o 33 - Relocate Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 o E - Existing no change TOTAL = 44 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTs >I' Opy CERTIFICATE OF COMPETENCY RE PROTECTION SPRINKLER SY John R =1 G ,016,„.441, S BUILDING SITE KEY PLAN AD 12 • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 EDDIE BAUER LANDLORD SCOPE 670 SOUTHCENTER BLVD. WESTFIELD SOUTHCENTER TUKWILA, WA 98188 PAID DATE: 5 DRAWN: ( SCALE: • Z,F7 z z 4,25't' 'IS [ofy. EGRESS DOOR O@36"CLEAR 180 OCCUPANTS EX T96 OCC. OR 01 o p' 0 Q, contractor shall patch and -epair existing wall to maintain 1 hour rating Ock OR OR ►,1 R 1 PR 30SF-= 12 64 O� h OR 01. THIS P RMIT SET DELINEATES THE NDLORD SCOPE OF WORK ONLY. FULL TENANT IMPRO EMENT DRAWINGS WIL BE SUBMITTED UNDER SEPARATE PERMi THERE WILL BE NO (DfN OCCUPANCY UNDER THIS PERMIT O(z Op. 1- \14>___ • EXIT # 1 (1) @ 72" CLEAR 0 OCCUPANTS BY TENANT Of QR SCALE: 1/8" = 1'-0" MIN Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 11- Add Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 o 33 - Relocate Globe Model GL5661 Standard Response 155° Brass Uprights 1/2 x 1/2 o E - Existing no change TOTAL = 44 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTs >I' Opy CERTIFICATE OF COMPETENCY RE PROTECTION SPRINKLER SY John R =1 G ,016,„.441, S BUILDING SITE KEY PLAN AD 12 • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 EDDIE BAUER LANDLORD SCOPE 670 SOUTHCENTER BLVD. WESTFIELD SOUTHCENTER TUKWILA, WA 98188 PAID DATE: 5 DRAWN: ( SCALE: • Z,F7 z z 4,25't' 'IS [ofy.