PP - 468 SOUTHCENTER MALL - BLUE C SUSHI - PERMITS AND PLANS
468 SOUTHCENTER MALL ASSOCIATED PERMITS 19-F-100 08-F-181 19-S-077 08-S-133 19-H-121 08-H-242 461014,4 4itt SITE LOCATION CITY OF TDIkWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Ahiaas and plans must be complete in order in be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: PLIGETFIRE pREVENTNp FIRE N 0Epj Site Address: Lito ? SO J (c7 (\e r (Cwt .y Suite Number: Floor Tenant Name: U. a e P �' S i 5 k k Property Owner's Name: UVe i 4 t. Q` i 5 Q A ce(v 4-1 MaiiingAddress: 2 S S o k h Ge (Ore -Tv k w .1 Q W J et 8( g City State Tap New Tenant? [I -Yes ❑-No CONTACT PERSON -if there are questions about the snbmittai. Name: e S`j j (,Q (106inston. Day Telephone: —12 S '-g l Tia 6 4 Company Name: C COQ (\ Fe ce. 1 % c -c lc (1 Mailing Address: E-mail Address (? C (Ql% nt P NICET III number: . City (ms s Fax Number L LAI G� City ofT:k Business License number. Ci)3V S— °41 SeM Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's tractor's bid price): $ 2 000 Scope of Work (please provide detailed infonmation): pta O, e c kk r"C q G� S • r ot I1 e W Add °I PERMIT APPLICATION NOTES C C'O e Valise of Constructiea— In all cases, a valve ofeons/mclion amount should be entered by the applicant. This tae will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every xery permit issued shall become invalid uoless'the work on the site authorized by such permit is commenced within 130 days ager is issdance,,or lithe yank anti nri2ed an the she by such permit is suspended or abandoned kr a period of ISO {lays after the time the work is cid. The Fire Marshal is authorized to grant, in .. writing, one or more extensions of time, for periods not more than I*0 days each. The extension shall be requested in writing and justifiable Cause defied_ I HEREBY CERTIFY THAT I HAVE REi13 4ND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZE AGENT: Signature: Print Name: Cr( s'VI t2 m bJlaid Plan Pert App doc PAID AQ'' 1 2019 Date: 3t311/1 TUKWILFa� (d/76C'T 8112/14 TFD FP Fonu 8' SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** `I 1 King Co. Assessor's Tax No.:�.�t0� 9,T) Site Address: f '1.0(\CRIkk1(' i��\1 Suite Number: Floor: Tenant Namer-cYX i. L ti 1 New Tenant? ❑ - Yes ❑ - No Property Owner's Name:', -Aa X i C.tjr;_ (--aelpk-. Mailing Address:t'l) Iihr) ` U) x ocict 42013 City CONTACT PERSON -if there are questions about the submittal. State Zip Name } '64):b 3'(D ul vu a Day Telephone(X) Q)tj1SS – Company Name:Cn 1CP X aialk. ` 11 I(lki,-, !'c,J p�v�5 Mailing Address: \-1 l Ave • 6 CUJ QQ J KM- cat 311 - City State Zip E-mail Address I ► ► . . i% ► ll.J. .1 I : A I C/C) Fax Number: ontractor's City of Tukwi �/�y NICET III number: Business License number: fJ ` UJ fl Z Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $1--V `` Scope of Work (please provide detailed information):t1 �(� G�`(,1Y M <'SU rsri / `Ir j 4 v�v�prov.�rnP��l c Accun (R d12N1_1?_6 • PERMIT APPLICATION NOTES Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR itlINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Pm BUILDING OWle OR AUTHORIZED AGENT: `•�( 2 2019 Signature , —, hi(il.� 'V�t&_ mg /� FIRE Date: 61.211"1 , TUKWILA Print Namc%, 1(i) , (�(� kK �1kX Day Telephone( (j ) WIS -39/14 0 Pian Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: '� �p SCD( A-1 &0.4444-r Mu 4(� Suite Number: t 0, Floor: Tenant Name: T vct v Property Owner's Name: Vi -6 e Mailing Address: "113ki.-) V CONTACT PERSON -if there are questions about the submittal. Name:N 1;,S11 C\ Cm rd -c' Company Name: Mailing Address: New Tenant? ❑ - Yes ❑ - No City Id kr 98160—° °0 State Zip Day Telephone: 7S3--11 Ht LO2 y) -1e ra.iAcUte 53Sc-e..A geA+f-Le City ate t E-mail Address: C j r`'t ja"0 "qrC • GOW� Fax Number: ^(0 3 — "1 s Lf Contractor's City of Tukwila � Business License number: (� � ,_ ` � 3 O� NICET III number: Total number of new/relocated devices or sprinkler heads: ! Valuation of Project (contractor's bid price): $ 2 t 2w' 63 Scope of Work (please provide detailed information): —1- vim� PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. w� y?101 Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID BUILDING "OWNER OR AUTHORIZED AG NT: Signature:// V 1 A 14 2019 TUKWILA FIRE Print Name: (vi tAS N/1 Date: (Q1 (' 2c`l Day Telephone: 7,5 3 3 - 'l t Z 1 Plan Permit App.doc 8/22/14 TFD FP Form 8 e/f S ed l( • FILE COPY FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Blue C Sushi 468 Southcenter Mall Permit No.: 08-H-242 Date: Mayl 29, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Nozzle heights above appliances to be per manufacturers installation guidelines. • Install splash guards between fryers and ranges/charbroilers. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Trapper Sushi 468 Southcenter Mall Permit No.: 19-H-121 Date: June 17, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Nozzle heights above appliances to be per manufacturers installation guidelines. • Fryers shall be installed with at least a 16 inch space between the fryer and surface flames from adjacent cooking equipment or a minimum 8 inch high steel or tempered glass baffle plate shall be installed between the appliances. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust system whenever cooking operations occur. The activation of the exhaust system shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. • If code compliant fire alarm notification is not already in place in the kitchen, a minimum 110 candela horn/strobe shall be installed above the kitchen hood suppression system manual pull station at a height of 80 inches above the floor. • A separate fire alarm permit from the Tukwila Fire Department is required for all fire alarm work. • The suppression system manual pull station shall be located no closer than 10 ft. and no farther than 20 ft. from the cooking equipment and be placed at a height of 42 to 48 inches above the floor. • The inside lower edge of the hood shall overhang or extend a horizontal distance of not less than 6 inches beyond the edge of the top horizontal surface of the appliance on all open sides. The vertical distance between the front lower lip of the hood and such surface shall not exceed 4 feet. • If cooking appliances are wheeled, the appliance wheels shall be set in tracks permanently mounted to the floor to ensure appliance is returned to original location if moved for cleaning or maintenance. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Trapper Sushi 468 Southcenter Parkway Permit No.: /7 -S -p77 Date: April 10, 2019 Reviewer: Kevin Varao Fire Prevention Specialist (206) 575-4407 option # 2 (Inspection Requests) (253) 856-4476 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. Customer BLUE C SUSHI 468 SOUTHCENTER 71 I KIWILA, WA 54478 GUARDIAN SECURITY L 1FE AND PROPERTY PROTECT!€).N Project BLUE C SUSHI Project # 54492 List of Materials Vendor Guardian Security Systems Inc 1743 1st Ave. South Seattle, WA 98134 Phone #: (206)622-6545 Fax #: (206)628-4990 Type of Equipment FIRE ALARM Date: 5/07/08 Item Qty. Manuf. Model Description Unit Pri Total Price 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) \ 19) 20) 21) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) 33) 34) 35) 36) 37) 38) 39) 40) 41) 42) 43) 44) 45) 46) 47) / \ 48) 49) - 50) Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens PAD -3 AD2-P HTRI-D HTRI-R SET CW,W SET-MC-CW,W ZR-MC-CW,W ZR-MC-W,W HFP-11 HFP-11-relay AD2-P Power Supply for Strobes With Standby** Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 Supervised Addressable Input Module Supervised Addressable Output Relay Module Interior Audible Speaker Annunciator Combination Speaker/Strobe Interior Visual Strobe Annunciator Interior Visual Strobe Annunciator Photoelectric Smoke Detector w/DB-11 Base Photoelectric Smoke Detector w/HR relay base Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 ** PAD -3 with BT -33 Conduit Systems: All smoke removal and detection and control devices in an approved metallic raceway and all devices in conduit per Standard • E 3 [] Without Ccrrments Ai- Po: d s y' Pu: T, _ Uttar 0 ti i FUKWILA FIRE DEPARTM1011. if Please call: 575.4402 :_J l; and give this job d No. 08—N -a` -r . ° r J exact awLiress for shut. 1 r ., .in or re,tJration approval. i nese plans t" T`• • Tui-'.1ita Fire Preventio7, . curt, �t city standards. oriss + a.dop`.od stand, add;. •• js artcr ,ds d. . ;.. •e eSpproval. , Final accc^`Z -•cc _ c' '.o "e d tsst and inspection by , The Tukvw;Ia I=1rc P .: '.' r i ureau. 1Date: By: AA^��% 1 SECTION IX - APPENDIX UL EX. 3470 ULC CEx747 Page 9-1 10-1-02 REV. 5 SYSTEM SELECTION GUIDE NOTE: System options do not cover all conceivable variations. They are listed here as a general guideline to show the most common type arrangement for multiple systems, Based on certain system designs utilizing manifolding, non-manifolding, 3 -tank systems, etc., other tank/cartridge combinations can be designed. The combinations below are based on 11 flow, 3.0 gallon tanks and 5 flow, 1.5 gallon tanks. More competitive designs may be available by utilizing 12 flow and 6 flow systems when appropriate. 'Total Tank Type of Carbon Dioxide Nitrogen Flow No.* Quantity System Type of Hardware Cartridge Required Cartridge Required 1-5 1 Single 1.5 Gal. Reg. Release 101-10 (423439) LT 20-R (423429) 6-11 1 Single 3.0 Gal. Reg. Release 101-20 (423441) LT 30-R (423435) 12-16 2 Double 1.5 Gal. Reg. Release 101-30 (423443) Double (423493) 3.0 Gal. Additional Tank 17-22 2 Double 3.0 Gal. Reg. Release 101-30 (423443)** Double (423493) 3.0 Gal. Additional Tank 23-33 3 Multiple 3.0 Gal. Reg. Release 101-20 (423441) LT 30-R (423435) 3.0 Gal. Reg. Actuator 101-30 (423443)*** LT -A-101-30 (423491) 3.0 Gal. Additional Tank 23-27 3 Multiple 1.5 Gal. Reg. Release 101-10 (423439) LT 20-R (423429) (Optional) 3.0 Gal. Reg. Actuator 101-30 (423443)*** LT -A-101-30 (423491) 3.0 Gal. Additional Tank 28-33 3 Multiple 3.0 Gal. Reg. Release N/A Double (423493) (Optional) (2) 3.0 Gal. Additional Tanks 34-38 4 Multiple 1.5 Gal. Reg. Release 101-10 (423439) LT 20-R (423435) 3.0 Gal. Reg. Actuator N/A LT -A-101-30 (423491) Double 3.0 Gal. Tank Box 34-38 4 Multiple 1.5 Gal. Reg. Release 101-30 (423443) Double (423493) (Optional) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)`** LT -A-101-30 (423491) 3.0 Gal. Additional Tank 39-44 4 Multiple 3.0 Gal. Reg. Release 101-20 (423441) LT 30-R (423435) 3.0 gal. Reg. Actuator N/A LT -A-101-30 (423491) Double 3.0 Gal. Tank Box 39-44 4 Multiple 3.0 Gal. Reg. Release 101-36 (423443)** (Optional) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)*** 3.0 Gal. Additional Tank Double (423493) LT -A-101-30 (423491) 45-49 5 Multiple 1.5 Gal. Reg. Release 101-30 (423443) Double (423493) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator N/A LT -A-101-30 (423491) Double 3.0 Gal. Tank Box 45-49 5 Multiple 1.5 Gal. Reg. Release 101-10 (423439) (Optional) 3.0 Gal. Reg. Actuator 101-30 (423443)*** 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)*** 3.0 Gal. Additional Tank • Based on 5 flow numbers for a 1.5 gal. system and 11 flow numbers fora 3.0 gal. system. •• If tanks ere manitdded, only a "double tank' nitrogen cartridge (Part No. 423493) can be used. ••' If tanks are manlfotded, either an LT -A-101-30 nitrogen cartridge (Part No. 423491) ora double tank cartridge (Part No. 423493) can be used. LT 20-R (423429) LT -A-101-30 (423491) LT -A-101-30 (423491) --NCO I Fire & Security. R-102•RESTAURANT SYSTEM NOZZLE COVERAGE SUMMARY SHEET ANSUL. R-102 OVERLAPPING PROTECTION The '245•nozzie, Part No. 419340, Is the only approved nozzle for overlapping (zone) protection. Appliance Type Maximum.Cooking Hazard Fryer 34 in. (864 mm) Deep x 5.8 sq. ft. (.54 sq. m) Griddle • 30 In. (762 mm) Deep x Unlimited Length Range 28 in. (711 mm) Deep x Unlimited Length Wok, Maximum 30 in. (762 mm) Diameter x 8 In. (203 mm) Deep Wok, Minimum11 in. (279 mm) Diameter x 3 in. (76 mm) Deep Braising Pan/lilt Skillet' 34 in. (864 mm) Deep x Unlimited Length Lava Rock Char -Broiler 32 in. (813 mm) Deep x Unlimited Length Charcoal Broiler 32 in. (813 mm) Deep x Unlimited Length (41n. (102 mm) Maximum Fuel Depth) Mesquite Wood Broiler 32 in. (813 mm) Delp x Unlimited Length (12 in. (305 mm) Maximum Fuel Depth) Gas Radiant Char -Broiler 36 in. (914 mm) Deep x Unlimited Length • Electric Char -Broiler 34 In. (864 mm) Deep x Unlimited Length "I See FJgure 1 for nozzle location. COVER MUST NOT 1.--1110-8 (0-15 cm) INTERFERE WITHEDGE OF DISCHARGE 1 T PATTERN I • ZONE CENTER UNE 40-45 IN. (1.1.1 m) TYCO SAFETY PRODUCTS. ONE STANTON STREET. MARI ETTE. WI 54143.2542 715.735-7411 Form No. F-2005010 Ce006 Maul Inoorpaated , Ufa h U.S.A./ i • Duct Plenum Nozzle Type Flow Points Width (In) Max. Side Length (In) . Max. Side Nozzle Placement (See Manual for More Detail) Min. Height (In) Max. Height (In) .. 0.: , . W : :t r_ 4 r:. .-. 12b�-,, '0In..-6.1n:4111 . 1 enu s., Perpendicular Protection Single Bank g 1 W/1100 1 48 .. .... ...,.. 2W +1100 48 Yar See Manual for more detail 1 ... ,,. See Manual for more detail Horizontal Protection V Bank 2 x 1N 2 48 >135 120 0 in. - 6 in. from end of plenum - 2 4 . Horizontal Protection V Sank 1W/1100 1 48 72 0'in. • 6 in. from end of plenum 1/3 the height of filter Perpendicular Protection V Bank 1W/1100 1 48 48 See Manual for more detail 1 20 R-102 OVERLAPPING PROTECTION The '245•nozzie, Part No. 419340, Is the only approved nozzle for overlapping (zone) protection. Appliance Type Maximum.Cooking Hazard Fryer 34 in. (864 mm) Deep x 5.8 sq. ft. (.54 sq. m) Griddle • 30 In. (762 mm) Deep x Unlimited Length Range 28 in. (711 mm) Deep x Unlimited Length Wok, Maximum 30 in. (762 mm) Diameter x 8 In. (203 mm) Deep Wok, Minimum11 in. (279 mm) Diameter x 3 in. (76 mm) Deep Braising Pan/lilt Skillet' 34 in. (864 mm) Deep x Unlimited Length Lava Rock Char -Broiler 32 in. (813 mm) Deep x Unlimited Length Charcoal Broiler 32 in. (813 mm) Deep x Unlimited Length (41n. (102 mm) Maximum Fuel Depth) Mesquite Wood Broiler 32 in. (813 mm) Delp x Unlimited Length (12 in. (305 mm) Maximum Fuel Depth) Gas Radiant Char -Broiler 36 in. (914 mm) Deep x Unlimited Length • Electric Char -Broiler 34 In. (864 mm) Deep x Unlimited Length "I See FJgure 1 for nozzle location. COVER MUST NOT 1.--1110-8 (0-15 cm) INTERFERE WITHEDGE OF DISCHARGE 1 T PATTERN I • ZONE CENTER UNE 40-45 IN. (1.1.1 m) TYCO SAFETY PRODUCTS. ONE STANTON STREET. MARI ETTE. WI 54143.2542 715.735-7411 Form No. F-2005010 Ce006 Maul Inoorpaated , Ufa h U.S.A./ i • Duct Nozzle Type Flow Points Perimeter (In) Diameter (In) No*zie Placement (See Manual . • for More Detail) Dyct Length (In) Single Nozzle,l flow nozzle '2.:. 1100 • • 1 50 16 See Manual for more detail Unlimited ... _ . t�tr�zzle f(o iv nortle .1 2W .. f:.. i,. :'i• ' C. .. «.3 .85-,,. .. :�_tlw ..n...;.,n � ,,�t3� Makivat., or more detail �..: , '. , Unlirriited ,„ MultipleNozzle .. .... ...,.. 2W +1100 .... 3 135 48 ... ,,. See Manual for more detail F,.....,,.. G;. e. Unlimited Multiple 2W Nozzle 2W — >135 >135 See Manual for more detail Unlimited R-102 OVERLAPPING PROTECTION The '245•nozzie, Part No. 419340, Is the only approved nozzle for overlapping (zone) protection. Appliance Type Maximum.Cooking Hazard Fryer 34 in. (864 mm) Deep x 5.8 sq. ft. (.54 sq. m) Griddle • 30 In. (762 mm) Deep x Unlimited Length Range 28 in. (711 mm) Deep x Unlimited Length Wok, Maximum 30 in. (762 mm) Diameter x 8 In. (203 mm) Deep Wok, Minimum11 in. (279 mm) Diameter x 3 in. (76 mm) Deep Braising Pan/lilt Skillet' 34 in. (864 mm) Deep x Unlimited Length Lava Rock Char -Broiler 32 in. (813 mm) Deep x Unlimited Length Charcoal Broiler 32 in. (813 mm) Deep x Unlimited Length (41n. (102 mm) Maximum Fuel Depth) Mesquite Wood Broiler 32 in. (813 mm) Delp x Unlimited Length (12 in. (305 mm) Maximum Fuel Depth) Gas Radiant Char -Broiler 36 in. (914 mm) Deep x Unlimited Length • Electric Char -Broiler 34 In. (864 mm) Deep x Unlimited Length "I See FJgure 1 for nozzle location. COVER MUST NOT 1.--1110-8 (0-15 cm) INTERFERE WITHEDGE OF DISCHARGE 1 T PATTERN I • ZONE CENTER UNE 40-45 IN. (1.1.1 m) TYCO SAFETY PRODUCTS. ONE STANTON STREET. MARI ETTE. WI 54143.2542 715.735-7411 Form No. F-2005010 Ce006 Maul Inoorpaated , Ufa h U.S.A./ i • tLICO / Fire & Security R-102 RESTAURANT SYSTEM NOZZLE COVERAGE SUMMARY SHEET a ANSUI.I Appliance Nozzle Type Flow 'Points Width (In) Max. Side Length , (In) Max. Side Multiple Nozzle wo/Drip Board Area Sq. In. Multiple Nozzle w/Drip Board Area Sq. In. Min. Nozzle Ht. (in):.: Max. Nozzle Ht. (in) Fryers without drip boards Split or No Split Vat 230 2 14 15 — — 27 47 245 2 14 ' 15 — . — 20 . 27 Fryers without drip boards Non -Split Vat MLY) 290 2 19.5 19 . — — 13 4 - • • 16 , 3N 3 19.5 194 — • — 21 34 3N 3 18 ' 18 — — 25 35 • Fryers with drip boards Split or No Split Vat' 230 2 14 21 210 294 27 47 245 2 14 21 210 294 20 27 Mors 1 with drip boards' • Non -Split Vat (ONLY) 290 2 19.5 25 3/8 370.5 495 13 . 16 ON _3 - 19.5 25 318 3.70.5 495 • 21 34 2 3N • 3 18 , 27 314 324. 497 . . 25 35 lilt Skilet/Braising Pan' Coverage Exception limitation are based on fryer Tilt SIdllets and Braising sizes including the drip boards. may exceed the maximum of 6.sq. ft. 'j Without back shelf With back shelf Without back shelf With back shelf •• 1N 1 12 32 —• — 30 ' 40 ' - 1°F t 12 28 — — 30 50 1F - • 1 12 20 - . - :. 40 48'i • tai I , ; 24 ' . 28 — - .. 40 501 260 2 • . 24 32— — 30 4 260 . 2 12 32 — — 30 40 2 x 290 4 36 28 — — 15 20 Griddle : . I 1N/1NSS 1 36 30 . . — — 35 40 290 2• 30t 24 —• — 30 50 260 2 48 30 — — I 30 50 290 2 48 30 — — 20 90 . 2120 2 48 30 — — 10 i 20 Chain Broiler' (Ovehead Protection). 2x 1W 2 34 30 • — — 10 26 Chain Broiler (Horizontal Protection) 2x 1N 2 • '31 ' 43 — . . — , Front edge; above the chain 1 - 3 in. Char Broiler. Gas -Radiant Electric Lava -Rock Natural Charcoal' Lava -Rock or Natural Charcoal' Wood Fueled' 1N/1 NSS 1 • 24 36 ' I — • — . 15 < 40 1N/1NSS 1 20 34 — — 20 50 1h1/1 NSS 1 13 24 — — 18' ; 35 1N/1NSS 1 12 ' 24 — — 18 40 3N 3 24 30 — — 14 ' ' 40 3N 3 24 30 — — 14 40 Upright Broiler 2 x 1/2N '1 30 32.5 Front edge; above the grate Salamander Broiler Internal Chamber 2 x 1/2N 1 30 ' 32.5 — 1N 1 16 29 —. •— — — 1 N nozzle location to be on the vodka) edge 6 to 12 in. in front and 0 to 12 In. above the top of broiler 1N 1 16 . 29 , - - 6-12 In. above either end Wdc 3.75 to 8 Inches deep l 3 to 6 inches deep 260 2 14 in. to 30 in. diameter — — • 35 45 1N/1NSS 1 11 in. to 24 in. diameter —• — • 30 40 +. • Formultiple nozzle protection of single fryers, see detailed information on pages4-10 to 4-11 of manual. ..a$Nfigure 1 for nozzle location, Wawa— chain broiler exhaust opening —12 in. x 12 In. (31 cm x 31 cm); and not less than 60% of Internal broiler size. 44 h maximum fuel de ! 04 416 as) maximum fuel depth. ....r Cn_ Z008 Tukwila Fire FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Blue C Sushi 468 Southcenter Mall Permit No.: 08-S-133 Date: April 24, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. Western States Fire Protection Co. 7102 180x` Ave NE Suite A-105 Redmond, WA 98052 (425) 881-0100 (425) 881-3030 FAX Fire Protection Systems Design *Fabrication •Installation Commercial •Industrial *Residential *Institutional Special Hazards *High Tech *Defense *Hangars Retrofit •Service •Inspection *Maintenance April 17, 2008 Alan Metzler Tukwila Fire Department 444 Andover Park East Tukwila, WA 98188 RE: Blue C Sushi --Westfield Southcenter Mall Response to:Tauzon Engineering Fire Sprinkler Review Letter 1. Dry Sprinkler will be installed in accordance with the 2007 NFPA 13. 2. A minimum of 6'-0" between sprinklers will be maintained. A. South of gridline K.5 and 7.6, two pendent sprinklers are dimensioned 5' -10th" apart. This is a cut length with take outs. Actual Center to Center dimension is 6'-0". B. South gridline L and 7.6, two upright sprinklers are dimensioned 5'-9'/2" apart. West head is obstructed by beam. C. South of gridline N and 7.6, two upright sprinklers are approximately 4'-9V2". West head is obstructed by beam 3. Washington State fire sprinklers certificate stamp will be provided. 4. The North arrow will be rotated to point to the left of the page. 5. Product data will be included with submittal to the City Of Tukwila. Adam Kantner Project Manager Western States Fire Protection, Inc. Dallas, TX *Austin, TX *Houston, TX •Albuquerque, NM *Decatur, IL •Denver, CO *Duluth, MN •Kansas City, KS Tac VPaae NV •Minnaannlic MN •Phrtaniv A7 •Portland (lR •Ranid City ST) •Salt T.alre City TIT •SOattiO WA •St. T.nnis MO [1r JI J 14 March 2008 Martin Sokulski Western States Fire Protection 7102 -180th Ave NE, Suite A-105 Redmond, WA 98052 RE: Westfield Mall — Blue C Sushi (Space #468) Independent Third Party Review — Fire Sprinkler System Dear Martin: Tuazon Engineering, PLLC 4322 NE r Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. It appears the sprinkler system shown is part of Zone T1 fed from the West Riser Room. The following was reviewed: • Fire Sprinkler Drawings — Sheet FP1 dated 4/11/08 • Hydraulic Calculations dated 4/10/08 The documents were reviewed for compliance with the 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. Ensure dry sprinklers are installed in accordance with 2007 NFPA 13 Para 8.4.10 such that the clearance around the sprinkler barrel is sealed and the barrel is of sufficient length to prevent freezing of the wet piping. 2. A minimum of 6 feet between sprinklers should be maintained unless baffles or different ceiling heights will exist. The following locations should be reviewed and corrected as needed: a. South of gridline K.5 and 7.6, two pendent sprinklers are dimensioned 5'-10Y2 " apart. b. South gridline L and 7.6, two upright sprinklers are dimensioned 5'-9%" apart. c. Sound of gridline N and 7.6, two upright sprinklers are approximately 4'-9'/ " apart. 3. Provide Washington State fire sprinkler certificate of competency stamp on the drawing and calculations. 4. The north arrow should be rotated to point to the left of the page. 5. Include applicable product data with the permit submittal to the City of Tukwila. A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or ericRtuazon.com with any questions regarding this review. • Westfield Mall — Blue C Sushi (#468) Third Party Review — Fire Sprinkler Systems 14 April 2008 Page 2 Respectfully, TUAZON ENGINEERING, PLLC Buz p Eric P. Tuazon, PE Fire Protection Engineer C.tnp, Fps,2C08 Rq R,20CB. Westar S.les tfeb&c CSiaMl4aµm Wazon sPcl'.r reuew clot 4ydruIic Summary Job Number: KS0303 Report Description: Ordinary Group II Job Job Number KS0303 Design Engineer Adam Kanter Job Name BLUE C SUSHI State Certification/License Number WESTESF136QF Address I 468 Southcentner Mall AHJ CITY OF TUKWILA Address 2 Job Site Southcentner Mall Suite # 468 Cy Tukwila State Wa Zip Code 98188 Drawing Name FP-1.cad Most Demanding SennWar Data 5.6 K -Factor 26.00 at 21.556 Occupancy Ordinary Group II Hose Allowance At Source 250.00 Density 0.20gpm/ft2 Area of Application 1077.00ft2 (Actual 1077.58ft2) Additional Hose Supplies Node Flow(gpm) Total Hose Streams 250.00 System Flow Demand 345.35 Total Water Required (Including Hose Allowance) 595.35 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Crowd 17.51 between nodes 290 and 288 Maximum Velocity Under Ground 1.30 between nodes 1 and 33 Volume capacity of Wet Pipes 1784.67gal Volume capacity of Dry Pipes 0.76ft3 Number Of Sprinlders Calculated 12 Coverage Per Spnnider 130.00ft2 suPP Node Hose Flow (gpm) Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required (psi) Safety Margin (Psi) 1 250.00 140.000 20.000 1 10900.00 139.446 I 595.35 49.331 90.115 , •. p.00ft ....................................... Contractor Number KS0303 Contact Name Adam Kantner Contact Title Project Manager Contractor Name Western States Fire Protection Phone 425.881.0100 Extension Address 1 7102 180th Ave Ne, Suite A-105 FAX 485.736.9032 Address 2 city Redmond State WA Zip Code 98052 Web -Site ke© M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00:20AM Page 1 Job Number: KS0303 Report Description: Ordinary Group II Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) Sprinkler 109 31.53 26.00 5.6 31.695 Sprinkler 112 31.66 26.00 5.6 31.973 Sprinkler 102 26.56 26.00 5.6 22.492 Sprinkler 103 27.08 26.00 5.6 23.391 Sprinkler 107 28.18 26.00 5.6 25.330 Sprinkler 110 31.58 26.00 5.6 31.799 i Sprinkler 101 26.00 26.00 5.6 21.556 Sprinkler 104 27.15 26.00 5.6 23.509 Sprinkler 105 27.24 26.00 5.6 23.667 Sprinkler 106 27.79 26.00 5.6 24.627 Sprinkler 108 28.92 26.00 5.6 26.677 Sprinkler 111 31.64 26.00 _ 5.6 31.923 ;'% Most Demanding Sprinkler Data M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00:42AM Page 2 Job Number: KS0303 Report Description: Ordinary Group 11 Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 19 1-11 42.144 33 5-8 BFP(-4.500) 45.046 161 1-11 P0(37 -8Y2) 42.084 203 13-3 fT(25-0) 36.739 232 13-3 P0(5-0) 35.580 235 13-3 P0(5-0) 35.878 242 13-3 2P0(8-0) 36.425 258 13-3 P0(5-0) 25.545 259 13-3 P0(5-0) 25.702 260 13-3 P0(5-0) 26.667 261 13-3 P0(5-0) 28.749 264 13-3 P0(5-0) 35.692 274 13-3 2P0(8-0) 36.236 285 13-3 P0(5-0) 26.794 286 13-3 P0(5-0) 26.964 287 13-3 P0(5-0) 27.995 288 13-3 P0(5-0) 30.196 290 13-3 2P0(8-0) 36.182 292 13-3 P0(5-0) 35.825 1 -4-0 S 49.331 345.35 109 16-5% Spr(-31.695) 31.695 31.53 112 16-5% Spr(-31.973) 31.973 31.66 102 16-5Y2 Spr(-22.492) 22.492 26.56 103 16-5% Spr(-23.391) 23.391 27.08 107 16-5% Spr(-25.330) 25.330 28.18 110 16-5Yz Spr(-31.799) 31.799 31.58 101 16-9Y2 Spr(-21.556) 21.556 26.00 104 16-5Yz Spr(-23.509) 23.509 27.15 105 16-5Yz Spr(-23.667) 23.667 27.24 106 16-514 Spr(-24.627) 24.627 27.79 108 16-514 Spr(-26.677) 26.677 28.92 111 16-514 Spr(-31.923) 31.923 31.64 © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00:45A M Page 3 Job Number: KS0303 Report Description: Ordinary Group 11 Pipe Type A(� © Diameter Flow Velocity HWC Friction Loss Length Eq. Length Total Length Pressure Summary Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings es Route 1 SP 1.049 0=26.00 9.65 C=120 0.211434 4-6Y2 Pf 2.445 101 16-9% q=26.00 K=5.6 21.556 Spr(-21.556) 7-0 Pe 1.544 258 13-3 25.545 E(2-0), PO(5-0) 11-6Yz Pv BL 1.610 Q=26.00 4.10 C=120 0.026249 6-0 Pf 0.157 258 13-3 25.545 Pe 0.000 259 13-3 25.702 6-0 Pv BL 1.610 0=52.56 8.28 C=120 0.096517 10-0 Pf 0.965 259 13-3 25.702 Pe 260 13-3 26.667 10-0 Pv BL 1.610 0=79.64 12.55 C=120 0.208223 10-0 Pf 2.082 260 13-3 26.667 Pe 261 13-3 28.749 10-0 Pv BL 1.610 Q=107.83 16.99 C=120 0.364715 8-6Yz Pf 7.486 261 13-3 28.749 12-0 Pe 274 13-3 36.236 2LtE(2-0), PO(8-0) 20-6Yz Pv CM 4.260 0=282.15 6.35 C=120 0.018916 10-0 Pf 0.189 274 13-3 36.236 Pe 242 13-3 36.425 10-0 Pv CM 4.260 0=345.35 7.77 C=120 0.027492 11-5 Pf 0.314 242 13-3 36.425 Pe 0.000 203 13-3 36.739 11-5 Pv CM 6.357 0=345.35 3.49 C=120 0.003914 16-11 Pf 0.435 203 13-3 36.739 94-3Y2 Pe 4.910 161 1-11 42.084 fE(12-7), CV(40-3), GV(3-9Yz), 111-2Yz Pv PO(37-8'/z) FM 8.329 Q=345.35 2.03 C=120 0.001050 24-8Y2 Pf 0.060 161 1-11 42.084 32-0 Pe 0.000 19 1-11 42.144 2fE(16-0) 56-81A Pv MS 10.020 0=345.35 1.41 C=120 0.000427 20-2 Pf 4.537 19 1-11 42.144 67-0 Pe -1.635 33 5-8 45.046 3LtE(16-0), BV(19-0), BFP(-4.500) 87-2 Pv UG 10.400 Q=345.35 1.30 C=140 0.000268 231-1 Pf 0.085 33 5-8 45.046 86-1 Pe 4.200 1 -4-0 49.331 2LtE(25-6), E(35-1), S 317-2 Pv = Route 2 SP 1.049 0=26.56 9.86 C=120 0.219917 3-3 Pf 1.810 102 16-5Yz q=26.56 K=5.6 22.492 Spr(-22.492) 5-0 Pe 1.400 259 13-3 25.702 P0(5-0) 8-3 Pv =• Route 3 SP 1.049 0=27.08 10.05 C=120 0.228030 3-3 Pf 1.876 103 16-5% q=27.08 K=5.6 23.391 Spr(-23.391) 5-0 Pe 1.400 260 13-3 26.667 P0(5-0) 8-3 Pv 6r Route 4 SP 1.049 0=27.15 10.08 C=120 0.229091 3-3 Pf 1.885 104 16-5Yz q=27.15 K=5.6 23.509 Spr(-23.509) 5-0 Pe 1.400 285 13-3 26.794 P0(5-0) 8-3 Pv BL 1.610 0=27.15 4.28 C=120 0.028441 6-0 Pf 0.170 285 13-3 26.794 Pe 286 13-3 26.964 6-0 Pv BL 1.610 0=54.40 8.57 C=120 0.102848 10-0Y2 Pf 1.031 286 13-3 26.964 Pe 287 13-3 27.995 10-0Y%Pv BL 1.610 0=82.19 12.95 C=120 0.220689 9-11% Pf 2.202 287 13-3 27.995 Pe 288 13-3 30.196 9-11% Pv BL 1.610 Q=111.11 17.51 C=120 0.385523 7-6% Pf 5.986 288 13-3 30.196 8-0 Pe 290 13-3 36.182 P0(8-0) 15-6Yz Pv CM 4.260 Q=142.75 3.21 C=120 0.005363 10-0 Pf 0.054 290 13-3 36.182 Pe 274 13-3 36.236 10-0 Pv = Route 5 SP 1.049 Q=27.24 10.11 C=120 0.230518 3-3 Pf 1.897 105 16-5Yz q=27.24 K=5.6 23.667 Spr(-23.667) 5-0 Pe 1.400 286 13-3 26.964 P0(5-0) 8-3 Pv = Route 6 SP 1.049 0=27.79 10.32 C=120 0.239153 3-3 Pf 1.968 106 16-5Yz q=27.79 K=5.6 24.627 Spr(-24.627) 5-0 Pe 1.400 287 13-3 27.995 P0(5-0) 8-3 Pv 0/ Route 7 M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11: 00:46A M Page 4 Job Number: KS0303 Report Description: Ordinary Group II Diameter Flow Velocity HWC Friction Loss Pipe Type Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream SP 1.049 Q=28.18 10.46 C=120 0.245460 Length Eq. Length Total Length Pressure Summary 107 16-51A q=28.18 261 13-3 K=5.6 25.330 Spr(-25.330) 28.749 PO(5-0) 3-3 5-0 8-3 Pf 2.020 Pe 1.400 Pv ▪ Route 8 SP 1.049 Q=28.92 10.74 C=120 0.257517 108 16-51A q=28.92 K=5.6 26.677 Spr(-26.677) 288 13-3 30.196 P0(5-0) 3-3 5-0 8-3 Pf 2.119 Pe 1.400 Pv 08. Route 9 SP 1.049 Q=31.53 11.70 C=120 0.302024 109 16-5% q=31.53 K=5.6 31.695 Spr(-31.695) 232 13-3 35.580 P0(5-0) 3-3 5-0 8-3 Pf 2.485 Pe 1.400 Pv BL 1.610 Q=31.53 4.97 C=120 0.037495 232 13-3 35.580 242 13-3 36.425 2LtE(2-0), PO(8-0) 10-6% 12-0 22-6% Pf 0.845 Pe Pv ear Route 10 SP 1.049 Q=31.58 11.72 C=120 0.302938 110 16-5% q=31.58 K=5.6 31.799 Spr(-31.799) 264 13-3 35.692 P0(5-0) 3-3 5-0 8-3 Pf 2.493 Pe 1.400 Pv BL 1.610 Q=31.58 4.98 C=120 0.037609 264 13-3 35.692 274 13-3 36.236 2LtE(2-0), PO(8-0) 2-5% 12-0 14-5'% Pf 0.544 Pe Pv imp Route 11 SP 1.049 Q=31.64 11.75 C=120 0.304032 111 16-5% q=31.64 K=5.6 31.923 Spr(-31.923) 292 13-3 35.825 P0(5-0) 3-3 5-0 8-3 Pf 2.502 Pe 1.400 Pv BL 1.610 Q=31.64 4.99 C=120 0.037744 292 13-3 290 13-3 35.825 36.182 PO(8-0) 1-5% 8-0 9-5%. Pf 0.358 Pe Pv ▪ Route 12 SP 1.049 Q=31.66 11.75 C=120 0.304469 112 16-5% q=31.66 235 13-3 K=5.6 31.973 Spr(-31.973) 35.878 PO(5-0) 3-3 5-0 8-3 Pf 2.506 Pe 1.400 Pv BL 1.610 Q=31.66 4.99 C=120 0.037799 235 13-3 242 13-3 35.878 36.425 2LtE(2-0), PO(8-0) 2-5% 12-0 14-5% Pf 0.547 Pe Pv 0 0jWgn#> '::fie ql�.: n9.:.....:.:....:....::....:..:...:.::..:.95.x.:.............. ( Schedule 40 Steel Pipe Inside Diameter Actual Inside Diameter 4.87 = Factor G:1l'•'' ''dolt ':: Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 (X, ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00:46A M Page 5 Job Number: KS0303 Report Description: Ordinary Group 11 Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Upstream AO BL CM DN DR DY FM FR MS OR RN SP ST UG Elevation Discharge K -Factor Pt Pn Fittings Length Eq. Length Total Length Pressure Summary .......................: Arm -Over Branch Line Cross Main Drain Drop Dynamic Feed Main Feed Riser Miscellaneous Outrigger Riser Nipple Sprig Stand Pipe Underground �F1JS:Ei Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve De1V Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11 Y° Elbow Ee2 22%° Elbow f Flow Device FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap (M� © M.E.P.CAD, Inc. AutoSPRINKO VR5 v5.2.6 04/22/2008 11:00:46A M Page 6 • Job Number: KS0303 Report Description: Ordinary Group II Supply at Node 1 Pressure, psi in 8 A 8 c(n S 8 8 cCO 11111. 1t 11111111 1 111 tittt11111.111i1 1 11111 1111111.111111111.ttttt1tttt1 1 1111 1 111111111 1 11 Static Pressure 140.000 595.35 445.35 with hose @ 49.331 streams S stem demand curve 10900.00 @ 20.000- 1111111111111111111 11 1 1 1 1 1 1111111111 1 11111 1 11 1 1 11 f 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11111 I I I I I 1111 U 71002200 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.446 @ 595.35 System Demand 345.35 @ 49.331 System Demand (Including Hose Allowance) 595.35 @ 49.331 [by © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00:49A M Page 7 Job Number: KS0303 Report Description: Ordinary Group 11 [Uy ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00: 50A M Page 8 Type 1 KITCHEN HOOD 12"W x 24"L 2w 13'6" HOOD A Fire 6 Gia 22 -Flo PULL STATION (10-20ft from hood) GAS VALVE El ®® • o®® i Steamer Range -Shelf Griddle (36"L x 24"D) (12"L x 24"D) (36"L x 24"D) 1 Table Fryer Fryer Fryer (18"L x 24"D) (16"L x 21"D) (16"L x 21"D) (16"L x 21"D) PAID jI,Jt! 14 201Y T UKWILA Fi F 3ev Customer:TRAPPER SUSHI - R1, 468 Southcenter Mall Systems: Ansul R102 - 6 Gallon Fire System, 22 Flow Point Capacity Proposal Date: 4/26/2019 Drawn by: Joshua Gualco Approved by: 15 TOTAL FLOW POINTS FOR SYSTEM Li Without Comments As Noted In Red Per The Attached Letter These plans have been eviewed by The Tukwila Fire Prevention Bureau fnr conformance with current City standards, P,C i 1s is 3Libject to errors and omissions which r..a: violations of adopted standards and The responsibility for the adequacy of des!c i Totally with the designer. Additions, c elelio. ; f. .Y.,.i:;',0 s to these drawings aft this date Mil T.of u tFce and will reouire resus bmitiai ofr' 4: ;; a'� ;:lie rr:'tip : 9ubsepuerl 3ppro1,.. Final accepts; ce 1, sub, =ct oto 1 ?ti test and inspection o. The Tukwila Hre Preven k: � iureau. Date: s -//ice// 9 T F� 375:iO7 ill givia this F3v : A Permit No. and e: pct address for shut- down hutdarn or relor3UUof approvvie SHEET NUMBER SHEET TITLE Fl H 1 FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON FA -01 SYSTEM INFONATION FA -02 TYPICAL WI SING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS FA -04 FIRE ALA SYSTEM PLA\ SHEET INDEX ADD 2 NEW CEILING MOUNT SPEAKER/STROBES TO AN EXSITING FIRE ALARM SYSTEM SCOPE OF WORK WISE SCHEDULE A\ CO\DUIT FILL CHAT WIRE DESIGNATIIN SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 ' FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END EXPIRES 09/01/2020 FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION.. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNCANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MININUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 2 E E E E E E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER E POWER SUPPLY PAD -3 SIEMENS EXISTING 66" A.F.F. TO TOP FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2" EXTN CEILING ®E SMOKE DETECTOR (EXISTING) HFP-1 1 SIEMENS EXISTING CEILING ®E D DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS EXISTING VERIFY IN FIELD TSM DUCT DETECTOR E TEST SWITCH (EXISTING) TSM -1 SIEMENS EXISTING VERIFY IN FIELD HT -R INTERFACE MODULE E WITH RELAY (EXISTING) HTRI-R SIEMENS EXISTING VERIFY IN FIELD FIRE ALARM SLE STROBE (EXISTING) ZR -MC -W SIEMENS EXISTING CEILING SE FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING KH E KITCHEN HOOD (EXISTING) F.B.O. F.B.O. N/A VERIFY IN FIELD TENANT J -BOX F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N /A N/A N/A N/A NOT APPLICABLE N/A N /A N/A N/A SYMBOLS LEGEND r- II NORDSTROM 3 LEVELS 171,2755f iJ AYLN MADE h N4b?.STY1 CiFTS ,UO macys LEVELS T1-£ never ?=EPEE AcE'�%Ci,BE Dftriruoi _`_1 250,407sf TRAPPER'S SUSHI 468 PAnus sRrL_.,.:..s. K:) JC• P..Tenney • 3 LEVELS 276.468sf R. L._,,..:..,. aan :FESTA:.RAN PAM J FSTAARAN TIG FE1E SIJ. MZJ,/A'S RESTAURANT •C,A h BAR WIRE DESIGNATION GENERAL NOTES SITE PLAN PAID HAt 2 2019 TUKW l AF9RE c .v' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 04/30/19 _ z ccs 2 26 Qc�cI- U3 2 W O WM it (I) 21( EL QQ U) � co CCWry.�c IJ. LL 1-- J 4CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/30/19 BACKROUND PLAN PROVIDED BY: 10B NUMBER:45432- FA-01 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET °Q THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. PUCK OVER 3' WIDE: SAMPLE 1IJBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-601{Z DEDICATED EMERGENCY FROM EXISTING MAIN FACP C CABLE C' CABLE N LL 07: T 0 0 CI PAD -3 0 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 S B 0 0 3.6k E0L 0 0 (-) (+) (-) (+) HARD LID CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE 2, NAC S4 NAC S3 NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N ;CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) STROBE SPEAKER (+) () C FROM PREVIOUS ADDRESSABLE DEVICE TBI 01010®®©0 ®®9 10 NO COM NC TO FAN SHUTDOWN EOLR 470 SWITCH + INPUT LED TSM -1 0 00 + TO NEXT ADDRESSABLE DEVICE TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) (-.) STROBE STROBE SPEAKER (-) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE cn O M O u) J Z NG AND MOUTN CC J U SCALE: NOT TO SCALE` DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/30/19 BACKROUND PLAN PROVIDED BY: .10B NUMBER:45432—Ij SHEET (� FA -02 J FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project:. TRAPPER'S SUSHI Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLY Date: April 30, 2019 Module/Device Qty Standby Total Standby Alarm Total Alarm (mA) (mA) (mA) (mA) Power Module 1 15 15 0 140 140 0 A:TOTAL FIRE ALARM POWER SUPPLY 15 140 B Auxiliary Device Current 0 0 C : Notification Appliance Load (Max. Total / mA) 0 D E F G H J K 1007 Total(A)= ` 15 Total(B)= CALCULATION 1147 Total current ratings of all devices in system (line A + line B + line C) 15 1147 Total current ratings converted to amperes (line D x .001) 0.015 1.147 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.0955451 Add lines G and I Total Standby and Alarm AH 0.4555451 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.54665412 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR). 7 *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP -HR *** Notification Appliance Circuit Detail PROJECT: TRAPPER'S SUSHI Panel: _ EXISTING BPS PAD -3 REMOTE POWER SUPPL Date: _ April 30, 2019 Wire Resistance 2.58 CURRENT TOTAL 1007.00 NEW 1 EX 4 EX 2 DEVIC SET -MC -CW @15cd SET -MC -CW @30cd SET -MC -CW @75cd SET -MC -CW @95cd ZR -MC -W @15cd 7 Total Wire Resistance R) Total Device Load, Amps (I) Voltage Drop ( E EOL Voltage 22.00 L*2)*(R/ft) :(Total Cct Load) (E=I*R). 24-E) 1007 1.99 1.01 2.00 22.00 (OLD BLUE C SUSHI POWER SUPPLY AND DEVICES ) FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project:TRAPPER'S SUSHI Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLY Date: April 30, 2019 Module/Device Qty Standby Total Standby Alarm Total Alarm (mA) (mA) (mA) (mA) Power Module 1 15 15 0 140 140 0 A TOTAL FIRE ALARM POWER SUPPLY 15 140 B Auxiliary Device Current 0 0 C . Notification Appliance Load (Max. Total / mA) 0 D E F G H K 469 Total(A)= . 15 Total(B)= CALCULATION 609 Total current ratings of all devices in system (line A + line B + line C) 15 609 Total current ratings converted to amperes (line D x .001) 0.015 0.609 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.0507297 Add lines G and I Total Standby and Alarm AH 0.4107297 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.49287564 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP -HR *** Notification Appliance Circuit Detail PROJECT: TRAPPER'S SUSHI Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPL Date: April 30, 2019 Wire Resistance 2.58 CURRENT TOTAL= 469.00 NEIN 1 SET -MC -CW @15cd SET -MC -CW @30cd SET -MC -CW @75cd SET -MC -CW @95cd ZR -MC -W @15cd EX DEVIC TOTAL Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E )... ._ EOL Voltage 400 0 0: 469 14 450 22.91 (WL*2)*(R/ft) (Total Cct Load) (E=I*R) 24 - E) 469 2.32 0.47 1.09 22.91 ( OLD MR. TUX POWER SUPPLY AND DEVICES ) CALCULATIONS EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved re) 4000' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS I Lu F-- < 04/30/19 .z =52 T Jo) v) 0 z 0�0 U) Wzz 161C CL2 ~ cc �d� ~ cr LL � 6ALE: NOT TO SCALE -\ DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/30/19 BACKROUND PLAN PROVIDED BY: �0B NUMBER: 45432-1) SHEET (� FA -03 7.6 0 ExISTING r 6 0 11111111411111111111111P11111111111111111111111141101111111111IIII i = a =II A /,, A 7, ,zl oz.z.452:4 30Cd (E) ELEC./STOR. 102 CC 30'-0' =0001 I= 1=111 =1111 1101 (EXISTIN) 111111111111111111111111111111111111111111111110111111IIIIIIIIIIIIIIIIIII111111111111111111111116111111111111111111111111111 J8111111111111111illi1iii1111111111111111111111111111111111111111114111111m11111111111111IIIIIiIIIIIIIIIIIIIIIII (E) OFFICE 103 I .1 1 4. I FIELD vERIFT 11+ an n (E) BACK—OF—HOUSE 1 101 75Cd VE /I t sj 1 1 1 j t I V I I ss j ! I ; Is ti I ;i 1`. 1 1 ! I I (E) COMMON EXIT 100 ==t m CORRIDOR EXIT CORRIDOR I 116 1 (E) ALCOVE 112 j 1 j DINING l 104 75Cd VE FOOD PREP. 1 113 el 1 'I 111.11 1'1! 1 111 I 1,1 L F — el -s I It fi s 1 I 1 1111III. I r 11 1c I 1 1 HT -R IE TSM DED E LJ I. (E) MEN ?‘—' _,_/- -* 50d I 114 1 [II ll . /--- r -1 i / r---—j)ii- 1 \ 1 I 1 ii c i I . i• WOMEN 115 • 44 M N) STORAGE 1.061 ' 1=911 =I CI =1 12 =I 111 =11 =2 CI =I • se 1:I sk4..fe*:+104....Gte, 5EE R COOLER • .gatititTM‘MITM!"..ttiWnZeireitSr.MM•ZNard.#. -------- ---------------------------- A II BAR 105 1 J OLD B I \ I DINING 107 UE C SUSHI i" C11=1111 C=111 II =El IS =1 El =11 11 L 151d 1 111 =I 0 =CI 111 111 0 =1 IN =II ,=I 1,1-I L _ I — — ITSMTE F El =1 I Sill \ -, I ...--- -1, il = I / 1 ,f)----- \.. \ _ 0-- / 1 = = Ei _77- I = — 30Cd „ I 4'1.2 •\,i I SERVER STN.11 111 / 75Cd VE 4J 1 / HOSTESS STN_ 12=111111111=10110111=101=1111191111=10 L DINING 1 110 1 l.j 1 111 1 75Cd VE 11 UU --TUX SHOP ENTRY I 108 h COUNTER91 DINING i10 CI =I = 0 =1111 D--- 0 101 CI= NO FIRE ALARM SYSTEM PLAN fis=a=0= = 0= =a EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I X IiIlliI. 1 ii .' i. . E i• 1 I 1 111 i I Iii1I I Ili 111 I, SHOP DRAWINGS il -1 li 11 DATE 04/30/19 C11=1111 C=111 II =El IS =1 El =11 11 L 151d 1 111 =I 0 =CI 111 111 0 =1 IN =II ,=I 1,1-I L _ I — — ITSMTE F El =1 I Sill \ -, I ...--- -1, il = I / 1 ,f)----- \.. \ _ 0-- / 1 = = Ei _77- I = — 30Cd „ I 4'1.2 •\,i I SERVER STN.11 111 / 75Cd VE 4J 1 / HOSTESS STN_ 12=111111111=10110111=101=1111191111=10 L DINING 1 110 1 l.j 1 111 1 75Cd VE 11 UU --TUX SHOP ENTRY I 108 h COUNTER91 DINING i10 CI =I = 0 =1111 D--- 0 101 CI= NO FIRE ALARM SYSTEM PLAN fis=a=0= = 0= =a EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I X DESCRIPTION SHOP DRAWINGS DATE 04/30/19 2 <<<<< 0. 'ALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/30/19 BACKROUND PLAN PROVIDED BY: JsOB NUMBER:45432-1i SHEET FA -04 BLUE C SUSHI General Notes VICINITY MAP (Suite# 468) SCALE: NTS 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced In accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. Existing Zone T1 6" Main WEST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE 8.1 C 0 Existing Zone T1 6" Main C C Oa' o >A s1\ 4 c'o co ri 3-11. 3-13'h C 0.11; 1- M 1 a5 -10'h tf \ 1 LD CLG 10-0 A.F.F �. d1I_f �L ��h ryri, X to J v �Q 11/2‘..'.. , JQ 1 5°--61-1---° 10 0 i'-6'.5 • 7.11 & ��be C Tt rte 11 123 1/21 n rocs gm irm EnT 1:31 MI rat MI SE3 IZ21 �� •r�tT 07\ ,CLG 8-6 A.F.F so X5-11 f 13 ,�. 0- i NvC., •4 11 n 4h 1'h 7-5 COOKING HOOD KITCHEN �h Oa\O� !• ! Gtr iy 10-0 maEi;M I att-Ita 11121 MI ll 1'h C CLG 12-6 A.F.F y •134:. i =�kNfbO 5-9 4-11 CLG 17-6 A.F.F o'I kN 114 8-64h JQ 6-11• O �hh 1'h 258 rn 3-9 JQ ,1' N,5;3 2-21/2d ' 10-9 450 S -9'h '1(4 Wal In Coale' Blue C Sushi Remote Area: Retail # 468 's 1-b 6-0 fb, • ®c) -` ®® 1'h k JQ 3-8' u1J 10-0 OOk00 1 6-3'' v 0\4O, 11-0'/2 ^h /! CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM / Ft' for 1130 Ft' SPRINKLER Reliable Model G4A ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER. SYSTEM REQUIRES: 345 GPM © 45.3 PSI ' At time of Design 17'-6" CLG: 28.75% AREA REDUCTION 4\A- 6-0 Ok 6-0'f { I 6-3' Ordinary Group II.0.20gpm/ft2 for 1077.00ft2 Il Existing T14" Main 6 0 FIRE SPRINKLER PLAN C 0- '',+F— 8-61A 6-9 • 5-2''A1 WI 4e -may`, ra 3 5 7 9 11 IEMI c 7.6 7 C 52 c TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD t CEILING TILE FIG. 809 SWIVEL SWAY BRACE FITTING laph FLEXHEAD DETAIL NOT TO SCALE 3J8' KWIK BOLT (2 IW EMBED LENGTH) FIG. 1000 "FAST CLAMP' SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NCH -THREADED BRACE PIPE FIG. 4A PIPE CLAMP FOR SWAY BRACE FIG. 908 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT 3/8' KWIK BOLT (2 IN' EMBED LENGTH) LATERAL BRANCHLINE RESTRAINT BRACE PIPE Thad NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III / EMT! Kw& Boll II 5 N1/ Dn7ledAnchor��T i 'G ' T/ L Bottom of Concrete to Center Line of Pipe Note on Plan Cut Rod Lgth Rounded to Nearest Inch Rod Coupling All Thread Rod Concrete Construction Swivel Ring Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE BLUE 0 SUSHI w z O Adam Kantner 2 v al N cu0 CONTRACTOR: SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE R3615 33 5.6 Upright Brass 155°F Reliable F1 FR SSU APPROVAL: CITY OF TUKWILA HYDRAULIC REFERENCE POINT 3 5.6 Pendent IAN Chrome 200°F Rel F1FR SSP Rec 2 5.6 Pendent Brass 200°F Rel F3 DR DRY HANGER SYMBOL BRANCHLINE RESTRAINT R3515 8 5.6 Pendent Chrome 155°F Rel F1 FR SSP Rec R5415 15 5.6 Pendent %' Chrome 155°F Rel G4A Concealed Total = 61 KS0303 Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE: 06/19/08 Western States Fire Protection Company 7102 180th AVE NE, STE {-105 - REDMOND, WA - 98052 Lic. #. WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/ DECATUR / DENVER /DULUTH/HOUSTON/KANSAS CITY LAS VEGAS /MIMIFAAPOLIS /PHOENIX/ PORTLAND /RAPID CITY/ST. PAUL /SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 BLUE C SUSHI 468 Southcentner Mali Tukwila ,Wa 98188 FIRE SPRINKLER PLAN SHEE FP - OF 1 T 1 SHEET INDEX FIRE TUKWILA, W7' SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLAN '•��.'`r`r.. ••;:. is Without Comments 0 A. Noted In Red Per The Attached Letter nese plans ha17e -`y The TLlic ,ila Fire Prevention currentcittl icrs and of adopted for fthe atter r .qti re a approval. and inspection by The Tukwila; Fire Gi::lbcU. Date: 0 By: M TUKWILA FIRE DEPARTMENt. Please call: 575-4407 and give this job No. OA -F -1 and exact address for shut. Town or restoration approval: NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N _ SYMBOL DESCRIPTI❑N NUMBER ❑F CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART ... . NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE • DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 112" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END SH YSTE INGTO GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING. DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL., DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS :SUPERVISED: NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT: CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, . WIRE,; .FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CARE; FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CEfBERUS DIVISION. : 6. DETECTORS SHALL NOT BE MOUNTED, IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS.: PER NEPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RSPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE.: CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE: IDENTIFICATION. 41, 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES:., g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS,REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. • 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND. 760 OE NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN'' REFERENCE TO DEDICATED. BRANCH POWER SOURCES. 120vac POWER SHALL NOT :BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALES BE. MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS] WILL BE ON THE RECORD DRAWINGS SET. • 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF 'ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION _ FOR PROTECTION DURING CONSTRUCTION. _ DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT: CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE. CONTINUOUS, 'FREE: OE GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. : 18. ALL CABLES SHALL BE MARKED AS INDICATED : ;ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHAM BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES ,OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METAWC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME. CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED I II SYMBOLS LEGEND QUANTITY 1 1 4 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FRCP I • FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM SDD-C .. SIEMENS REMOTE ANNUNCIATOR PROVIDED 66" A.F.F. TO TOP BPS I REMOTE BOOSTER IEX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP : INTERFACE MODULE HTRI-R ® I' ; : THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE VATH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS DUCT DETECTOR LOCATION Am TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT vLABEL SCXE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE I FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH 1 0 0 GROUND_ u0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 0 HTRI—R 4110 STATUS LED (0 0 0 0 N.O. COM N.C. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE L NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING--- \ TUBE INLET SAMPLING—\ TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE ILIFAC POWER SONJRCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE f(+) STOP IF LAST DEVICE .(-) FROM XLS CONTROL PANEL OR .1(¢) PREVIOUS ADDRESSABLE DEVICE LB RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 mitt DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04 u F 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTION. IA AI TB1 6j AAA A 1 2 3 4 5 6 HCP TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END OF LINE DEVICE (3.6K 1/4W) 0 SUPERVISED:____' SWITCH GROUND --- - r i 0 0 HTRI—D STATUS LED OD 0 0 NOT USED 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 -TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL WEL Se4LEE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC A A A 0 MOO U. 0 0 0 PAD -3 0 • INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- -1 2+ 2- 2 NC C NO + - + - + - + - + - El Lam] 24K NAC -4 NAC -3 NAC -2 NAC -1 END OF:i' I LINE DEVICE 3.6K i/4W? UPERVISED SWITCHI FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE . DEVICE LOOP NOT USED REMOTE DEVICE LOOP OZ____ FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V` CABLE) 470 OHMS 1W1 EOL 0 A1TCE INPU TCM -1 O • • 0 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SC LE: NONE C (4 - STROBE) SPEAKER (STR❑BE—) EARTH GROUND ;a I --►(+)TO NEST DEVICE:OR }, >(-) STOP IF LAST DEVICE v (STR❑BE) SPEAKER SPEAKER/STROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80- AF.F. - r 4S DEEP BOX W/ 1 -1/2 - EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE TCI>'NEXT DEVJCE OR • END .E(F LINE TO ;;NEXT DEVICE; OR END :. C)! ' LINE • NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPT TEMPERA +32' F (O C TO 10tt F C }TUMIDITY: O- X RELATIVE HUMIDITY. NON -CONDENSING HFP-11 SMOKE DETECTOR --� -31- FROM PREVIOUS ADDRESSABLE DEVICE OR POIMER SOURCE DATA IN (-) DATA IN (-F) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WEN USED IN CONJINCTDON VAIN DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMDXE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICE > (—) DATA OUT (F) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING fa -1743 -IST -1 -AVE: SO;; SEATTLE, WASHINGTON co CJ RELEASE/REVISIONS SPEAKER SUPPORT TILE----\ BRIDGE DESCRIPTION LLI SQUARE DEEP BOX , WITH 1-1/2' EXTENSION N. SHOP DRAWINGS to in CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) JUNCTION BOX MOUNTED ON CEILING FLEX \ JUNCTI MOUNTED A CEILING S N BOX PPORT 03 CO 2 1§Z 0 cc 0 co ,-/zifjo 011 TO NEXT DEVICE I, CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI BACKROUND PLAN PROVIDED BY: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved -SHEET FA -02 { { 2S 2S,2V,D i ., $,i ----------------- 4 } EOL -S2 19.93V Irufrrr�sr✓rrrrr�sfrr/ {% X • '14C,'") . 7F/..c 4l)'- • .R i iii �".Y.:.�rrrrr.•sz� { { D 1- 0 \kb.”, BLUE C SUSHI WESTFIELD SOUTIICENTER MALL SCALE 118"=V FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATI❑N SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. SIEMANS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER.. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT, Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved a 0 0 ct �CALE: 1/8" =1 ' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: .1.0B NUMBER:54492 % SHEET FA -03 j 1; 1, 1;• 11: r ':1 4.7 t is ! • .•, SYSTEM CALCULATIONS 0 - NORTH 1 11 11 1j\ :11 n. 1, / 1 • • .•••• \ .••• o 0 6 c, 14 / • 1 t .;" : . BLUE ,C SUSHI , .• •. • ' I BLUE C SUSHI .' i;,.: ,' :•,:, . , SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations : ' SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations . . • . . . DESCRIPTION SHOP DRAWINGS ' DATE on o in ... in .-.Hi • i;'). Current Load: <<<< Standby: Alarm: ' ,'; ,i•i:, Current Load: • Standby: :Alarm: , : • • Device Type Qty Amps Total Amps Total Device, Type . Qty Amps Total - Amps Total 43. Main System Board 1 0.03 0.03 0.030 0.030 •:-; : MainSystem Board 1 0.03 : 0.03 0.030 0.030 SET-MC@15CD.._._., . ,k-t-rode6615 111 - 1, 0.064 0.064 SET -MC @15CD SET -MC @30CD 1 0.064 . 0.064 1 0.098 0.098 0.098 0.098 Ef-ICiie- dfgo- 6 3 0.175 0.525 SET -MC @110CD - -SET-HMC-Cti15CD ' - SET-HMC-C@135CD _______________________ 0 233 . SET -MC @75CD 3 0.175 0.525 0.318 SET:I40 @110CD ' . . , SET-I-IMC-Cgn5CD .. . .. _ __ SET-HMC-C@135CD . _L • SEt-I4M-C-C@I -8-5CD ' ---- - - - '-' ZR -MQ @15C,D . _ ZR-iio ta6bb 0.233 0.318 0.318 SET-HMC-C@185CD ziri-fc di eco . 0.445 , . , . 0.318 . .• 4 0.064 0.256 0.445 24:ka--@i665 - ------- . 0.098 ,.,. 4 0.064.. , 0.256 FiEi:;---- ,_ ____ . 0.0015 , 0.098 , 0.03 Amps , 0.973 Amps HCP ,:i ; . . : 0.0015 - ;' Current Load: :; , 0.03 Amps For 24 Hours = 0.720 Amp -hours :..,,i ;.',1•.. • , 0Standby ..i 03 Amps 0 973 Amps ' . .4 H.,. Alarm Current .Load: . '0.973 Amps For 5 Minutes= 0.082 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours .. : . - ' " 25% Derating= 1.002 Amp -hours':,' Alarm Current Load: 0.973 Amps For 5 Minutes= 0.082 Amp -hours 4--.., . . ; Total System Current Load 1.002 Amp -hours '';..• !.;!i!... ' 25% Derating= . 1.002 Amp -hours ;,.:. r. • ;,,: 1: il • , •.•i.1,; • i: Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULAT • ON BLUE C SUSHI WESTFIEDSOUTHCITERMALL SCALE 1132'4 EOL -S2 21 EOL -S1 C 75 C 75 15 15 c 30 30 15 15 c 75 NOP 2S,2V,D BPS A BOX FACP I , ••• •• • •`• • .•-• •• • • •-• Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MAL- L Panel: !BLUE C SUSHI- . , ;wire Resistance 162 : Date: May 8, 2008 , S1 CURRENT TOTAL= 977 CIRCUIT:S1 I . ; ,; 44 ; QTY : Device Type ; 1 , arm Currentl Alarm Total 1 Wire Size ; ire Length, ! Voltage at EOL ; Circuit Total i '', , •,- , 0 ;SET -MC @15CD 64'0 0; • • 1 SET -MC ©30CD 1 SET-MC@75CD 981 - 981 1-T Total Wire Resistance ( R ) 0.81 (WL*2)*(R/ft) 175; 1751 ; Total Device Load, Amps (1) 0740, _14 0 SET -MC @110CD 2331 01 0 • :SET-HMC-C9115CD 318 tl: 1. Voltage Drop ( E 0.32 ) (Total Cct Load) ; _,. . I 0 ISET-HMC-C@177CD1. 445i ' 01 0 SET -HMC @135CD 0 SET -HMC @185CD 2 iZ-MC@15CD 0 1 Z -MC 930CD 0 iSET-MC-CW©110CD DEVICES= ,t1 ; . EOL Voltage 1. 20.0844 41 (E=T_ I * R) 318's 01 4451 Oi1 (20.4 - E) 641 1281 981 .2331 TOTAL mA=1 01 ; - OS 4011 12 250 1 20.07519 401 . , CIRCUIT.; S2 1 . , ; ; s ; , QTY ; Device Type ;Alarm Current; Alarm Total 1 VVire Size 1 VVire Length i Voltage at EOL ; Circuit Total -;', i 440 . SET -MC ©15615 641 oi _, . , :. ;,. !Total Wire Resistance ( R ) ; 0.82' , ' 2 SET-MC@75CD i 1751 350'----- ,(WL*2)*(R/ft) 0.58; !Total Device Load, Amps (1) i 7 1 SET -MC @3666 981 99-; 0 ,SET -MC ©110CD 2331 _0 SET-HMC-C@115CD 318 0 . i . Voltage Drop ( E ) 0.47 0 sr-Typic@177cD 445 (E= I * R) 1 0 !SET-HMC@135do 1 . 3181 0 , , -,4 . , -i. EOL\/ 0 2 1SET-HMC @185CD ; 4451 01 .., 2O4 - Eg)e 19.93 Z-MC@15CD 64 128 ; i-MC@30CD , ' O 981 , ; 0 SET-MC-CW@110CD 1 2331 :1 - , . , 1 01 (Total Cct Load) DEVICES=i 5'°ii TAL MA=1. 5761 12 1 • • - -Notification Appliance PROJECT: WESTFIELD.SOUTHCENTER MALL p 1J 4 • ---- . 2- 53 :. 19.9278412/ 576 Circuit Detail • . , .._...._„____.._ Panel: i PANDA EXPRESS ' , : !'t: i Wire Resistance 2.58 . : :::: , . , . . -- ' 41. r- : Date: !May 8, 2008 ; ill, CURRENT TOTAL=19 CIRCUIT:!SPEAKER CIRCUIT , QTY Device Type Current Alarm Total Wire Size 1 re Length ; Voltage at EOL Circuit Total • - 5 , 70.7Y 1 /8 9i . I Total Wire Resistance (_R ) 1.82 , ; ! 0 ,-- • 0 , ...•._ ____________ _________.........___ • ._. __... _________.....,• _______ ; ( WL* 2 ) * (R/ft). •,_ ......„ . 0 ;0 0 iTotal Devide Load, Amps (1) 0.01 I: i- • • .._ ; _; .._, 0 ,i . -----0 00 i II , - (Total Cct Load) 0 0L 0 Vo4ge-Drop (E) 0.02 : I, (E= I* R) 0 . 'OL . ' Of - EOL Voltage - - .,..._.,.. ____ ...._..... ,......... - ... •.. .. __.., .. . . L I 0 , 01 .- 0i i ii - i _ , ' I (20.4 - E) .. 20.38i 0 , • - : Ol 01 . f I , 0 i 0 : ' 016T DE1 44- ; ; 1 VICES=;'.5 . i L....,n.„1, _ ..__..•.___i4i_l___________....___. ....io_._..eie._.5...i{1 .4, 352 _ . . ; .• Tot _ . r-- -•• EX -,t • cu LU tr;) CO O• 1743 .IST AVE. SO., SEATTLE, WASHINGTON TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NVI DESCRIPTION SHOP DRAWINGS DATE on o in ... in < <<<< • CC w z w 0 0 w >°- CO KALE: 1/8'1=1' DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZAN I DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: ..1.0B NUMBER:54492 SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved. FA 04 .441 443 -43 •Ji BLUE C SUSHI General Notes VICINITY MAP (Suite# 468) SCALE: 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. C C C Existing Zone T1 6" Main c _ -;:rte,...; ,.:•, -, r, `.'�..re._�-.�,. 0 • 10-534 CLG 100 A.F.F 0.111 1E2 ICI EC 1E2 CC LZ1 CLG 8 • A.F. COOKING HOOD CZ rt x•. • ta . `e .t CLG 17-6 A.F.F 0 TYPICAL FLEXABLE SPRINKLER CONNECTION:'. FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXBEAD DETAIL TAIL NOT TO SCALE 39' KWIK BOLT (21W EMBED LENGTH) FIG.1000 "FAST CLAMP SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS law NON -THREADED BRACE PIPE 318' MIK BOLT R IAP EMBED LENGTH) FIG. OM NO -THREAD SWIVEL SWAY BRACE ATTACHMENT FIG. 4A PIPE CLAMP FOR SWAY BRACE LATERAL BRANCHLINE RESTRAINT BRACE PIPE e NON -THREADED BRACE PIPE LATERAL BRANCHLIKE RESTRAINT NOT TO SCALE Wal in Coale Hanger No. 07C HILTI Kwik Bolt III V1 TICE Ordinary Group II.0.20gpm/ft2 for 1077.00ft2 Existing T1 4" Main Rod Coupling Concrete Construction AA Thread Rod Weld stamps must be inspected before pipe is hung. Do not paint piping priAr to hydrostatic test approval. Swivel Ring Note on Plan: Hanger Number and W Dimension -Existing Zone T1 6" Main WEST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE FILE COPC �f TU# kgIL4 FIRE DEPARTM N Please call: 575-4407 and give this job No. W3—&-/33 end exact address for shuts ti own or restoration approval; HANGER DETAIL NOT TO SCALE Blue C Sushi Remote Area: Retail # 468 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY ctAss ORD HAZARD 11 MAX COVERAGE per HEAD 130 FF DENSITY .20 GPM / Ft' for 1130 Ft' SPRINKLER Reliable Model G4A ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 345 GPM © 45.3 PSI ' At time of Design 17'-6" CLG.=28.75% AREA REDUCTION K5 Without Comments AsNotedlnRed Per The Attached Letter i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is eubiewt to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void thi-s.acceptance and will require a resubmittal of revised drawings for subsequent approval. i Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: Y—� �. By: 41 •1 1 3 FIRE SPRINKLER PLAN 118"=1' 0 SYMBOL LEGEND 2 -WAY EARTHQUAKE BRACE REVISIONS DESCRIPTION DATE SYM. SIN QTY. R3615 33 5.6 Upright 3 5.6 Pendent 2 5.6 Pendent 4 -WAY EARTHQUAKE BRACE HYDRAULIC REFERENCE POINT HANGER SYMBOL BRANCHLINE RESTRAINT Sprinkler Legend K SPRAY ORIF. FIN. TEMP. %Z' Brass Chrome Brass rn 2. 008!Pm 0 R3515 22 • 5.6 Pendent Total = 60 155°F 200°F 200°F Chrome 155°F MFR./MODEL Reliable F1 FR SSU Rel F1FR SSP Rec Rel F3 DR DRY Rel F1FR SSP Rec APPROVAL: cm' OF TUKWILA CONT. NO.: KS0303 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 04/23/08 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/DECATUR/DENVER/DULUTH/HOUSTON/KANSAS CITU IAS VEGAS rM8eE:JPOLIS/PHOENIX/PORTLAND /RAPID CITY/ ST. PAUL/SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 BLUE C SUSHI 468 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER PLAN k'i a Fire SHEET 31 13C3" '-3 /2' VERIFY A009" 3'-31/2' VERIFY .77 1u tIt 0 RELOCATE (E) FIXTURE IF NECESSARY EXISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DUJGS /SCHEDULES L 1 EXISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DWGSJSCHEDULES { 1 17 2rt NO CEILING ABOVE WALK N COOLER - 3 TYP SEE KEC D1L 6 •4 1 � I FELE VER fV \ \ 1 I I 0 1 } J Y 1 1' U 0 /r CP n i f 4 i ' x,1 A3 1 t 5'-O' 11- 5'-6' li 744 11 11 EXIST'G. CEILING TO REMAIN THIS AREA, VERIFY NEW FINISHES W/ MF DWGS (REMOVE EXIST'G. LIGHT FIX- TURES, INSTALL NEW FIXTURES AS 61-1OWN 4 SCHEDULED) ' N % iv `_ —0 ti .,,i4 _ + R• 5 k� , a {{ Li _+ ` • JI CD 4 OD 1 ! , 'F 1 • P +s 3 ' 1 ti i 1 ilio '1 I r -.1a- p { : 1 I.i r i F.11 ' } i 25'-1' a 7'-O' AFF. BULKHEAD W c 1 _ NEW 6' 20 GA CEILIN -AMING m 16' OC W �, 1A � 74 '41 EXISTING CEILING/ (ETR) LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DWGSJSCHEDULES • • (ETR) « I -1 i (ETR) a 7 A3 1 a.• r • I 4441 , 11 6, e 'I, • R 1 ; , r.L} 1 ,. • / :41 ML , 1• t )! ATC,743 - (E) ' i t; ADJ 'CEILING 4 ;i':ta r + 1 4;' ,t 1=P1 D lv� R '4) ,P 11. sossismismosissosigpis NEW (3ULK-IEAD 1'-0' APP., IIS , •1'• is .. V' iK>X i y t,vR �' 1 —r--•—t_-.fs'e S, • I/ A , 1 Lh 1 4 /8 GYP. BR CEI ING - WALK IN GOOLE 10'-0' 101-0' 6'-O I0' -O' ,f .`L "--N:XISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DUJGS /SCHEDULES FACE OF SOFFIT TO ALIGN W/ FACE OF COUNTER I EELOUJ EXISTING CEILING/ L'GHTING TO REMAIN, VERIFY FINISHES W/ MF DWGS./66-1EDULES IREPLACIZE, 101-4N1 ig 4k49 5 =l EXPOSED TO STRUCTURE w / 6'-0' PENDANT ,h FROM GLAZING, Tr' K./ e:// E' ;01, 101-01 SEATING/EQUIP. SHOWN !BELOW FOR REFERENCE EI FROM GLAZING Or r .49 • IL ct PENDANT' FROM GLAZING I I if,- I 11.1/.. I r- :1 4-- '-2 1/2 IL_ -01 FlexHead Sprinkler Drop - Corrugated stainless steel hcse with stainless steel bral Adiu, table Hub Multi Port Bracket EXISTING MERCANTILE TENANT SPACE FLEXHEAD Flexhead -Commercial ceiling Unit T -Bar Ceiling Installation Model #2024,2036,2048,2060,2072 • REIMER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C—CLAMP WITH SET SCREW 3/8' ALL TNREAD REID PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL TEELOX MECHANICAL BRANCH CONNECTOR SIZE A 1-1/4 x 3/4 2 x 1/2 2 x 3/4 2-1/2 x 3/4 • 2 2-1/16 2-1/8 2 2-1/16 2-1/8 2-5/16 2-3/8 2-7/16 2-9/16 2-11/16 2-3/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-13/16 1-13/16 1-13/16 2-1/16 2-1/8 2-1/8 1-3/16 1-3116 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 NO soaal cols% • TUKWILA FIRE DEPARTMENT Plena ca4206-575-4107 and giv.2. this Fire Permit No. and for st-N.it- Design per NFPA 13 — Ordinary Hazard 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions • rA—PL4r: 04:9 puGET. SOIJND "9RE PREVENTION DEPT • 8 Add Reliable Model G5-56 Quick Response 165° Concealed Pendents % x • 1 — Add Globe Model GL5636 Quick Response Dry Pendent % x % im cust-nrioATia OF II FIRE PROTECTION SPRINKLER SYSTE 1 1 • John Thomas DeMartino 9794 -1091 -CG Level 3 Crown Fire Protecaon, Inc ile- 1801-13 422 Reflected Ceiling Plandwg Date/TIme January 10, 2019 5-29 PM Scale 1..48 Xrere 0. 10 ,All concepts, designs, arrangements, and clata indicated on these documents are the prc developed for use on, and in connection with the specified proJect. None of such Idea' any person, firm, or corporation for any purpose whatsoever without permission vf G A. Miller A oterissill CROWN FIRE PROTECTION INCORPORATED PO BOX 12113 MLL CREEK, WASHINGTON 98082-0113 PH (425) 481-7669 Trapper Sushi 468 Southcenter Parkway Tukwi1a, WA 98188 • • • • 1 • 0 111 • mo. Atm c\1 nxiALAARE DATE y-214,1 DRAWN J/G, SCALE 7. t '-101/2' ' . 6'-0' _ - I ' 6'-o' '. �I'-lo In ' .• r , _ • sI - n'" li". r }{ '. R .{ air 3r s t' /• i.`•.. JPi M� s `y..30' -O' R . ' . ' R :> ♦ . sz ' r._,..1...../ i �, J�� �,,: ! 1 T ,I i i� 1 • ., , .. � , , ' " i N { 0.43' L 4'-2 1 -----l1 1-4'.,211/2'— I. t414 I/2`-- -1 4'-4 1/21.-7-12'-0' j 10'-0' 101-0' 6'-O I0' -O' ,f .`L "--N:XISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DUJGS /SCHEDULES FACE OF SOFFIT TO ALIGN W/ FACE OF COUNTER I EELOUJ EXISTING CEILING/ L'GHTING TO REMAIN, VERIFY FINISHES W/ MF DWGS./66-1EDULES IREPLACIZE, 101-4N1 ig 4k49 5 =l EXPOSED TO STRUCTURE w / 6'-0' PENDANT ,h FROM GLAZING, Tr' K./ e:// E' ;01, 101-01 SEATING/EQUIP. SHOWN !BELOW FOR REFERENCE EI FROM GLAZING Or r .49 • IL ct PENDANT' FROM GLAZING I I if,- I 11.1/.. I r- :1 4-- '-2 1/2 IL_ -01 FlexHead Sprinkler Drop - Corrugated stainless steel hcse with stainless steel bral Adiu, table Hub Multi Port Bracket EXISTING MERCANTILE TENANT SPACE FLEXHEAD Flexhead -Commercial ceiling Unit T -Bar Ceiling Installation Model #2024,2036,2048,2060,2072 • REIMER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C—CLAMP WITH SET SCREW 3/8' ALL TNREAD REID PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL TEELOX MECHANICAL BRANCH CONNECTOR SIZE A 1-1/4 x 3/4 2 x 1/2 2 x 3/4 2-1/2 x 3/4 • 2 2-1/16 2-1/8 2 2-1/16 2-1/8 2-5/16 2-3/8 2-7/16 2-9/16 2-11/16 2-3/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-13/16 1-13/16 1-13/16 2-1/16 2-1/8 2-1/8 1-3/16 1-3116 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 NO soaal cols% • TUKWILA FIRE DEPARTMENT Plena ca4206-575-4107 and giv.2. this Fire Permit No. and for st-N.it- Design per NFPA 13 — Ordinary Hazard 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions • rA—PL4r: 04:9 puGET. SOIJND "9RE PREVENTION DEPT • 8 Add Reliable Model G5-56 Quick Response 165° Concealed Pendents % x • 1 — Add Globe Model GL5636 Quick Response Dry Pendent % x % im cust-nrioATia OF II FIRE PROTECTION SPRINKLER SYSTE 1 1 • John Thomas DeMartino 9794 -1091 -CG Level 3 Crown Fire Protecaon, Inc ile- 1801-13 422 Reflected Ceiling Plandwg Date/TIme January 10, 2019 5-29 PM Scale 1..48 Xrere 0. 10 ,All concepts, designs, arrangements, and clata indicated on these documents are the prc developed for use on, and in connection with the specified proJect. None of such Idea' any person, firm, or corporation for any purpose whatsoever without permission vf G A. Miller A oterissill CROWN FIRE PROTECTION INCORPORATED PO BOX 12113 MLL CREEK, WASHINGTON 98082-0113 PH (425) 481-7669 Trapper Sushi 468 Southcenter Parkway Tukwi1a, WA 98188 • • • • 1 • 0 111 • mo. Atm c\1 nxiALAARE DATE y-214,1 DRAWN J/G, SCALE 468 SOUTHCENTER MALL ASSOCIATED PERMITS 19-F-100 08-F-181 19-S-077 08-S-133 19-H-121 08-H-242 461014,4 4itt SITE LOCATION CITY OF TDIkWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Ahiaas and plans must be complete in order in be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: PLIGETFIRE pREVENTNp FIRE N 0Epj Site Address: Lito ? SO J (c7 (\e r (Cwt .y Suite Number: Floor Tenant Name: U. a e P �' S i 5 k k Property Owner's Name: UVe i 4 t. Q` i 5 Q A ce(v 4-1 MaiiingAddress: 2 S S o k h Ge (Ore -Tv k w .1 Q W J et 8( g City State Tap New Tenant? [I -Yes ❑-No CONTACT PERSON -if there are questions about the snbmittai. Name: e S`j j (,Q (106inston. Day Telephone: —12 S '-g l Tia 6 4 Company Name: C COQ (\ Fe ce. 1 % c -c lc (1 Mailing Address: E-mail Address (? C (Ql% nt P NICET III number: . City (ms s Fax Number L LAI G� City ofT:k Business License number. Ci)3V S— °41 SeM Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's tractor's bid price): $ 2 000 Scope of Work (please provide detailed infonmation): pta O, e c kk r"C q G� S • r ot I1 e W Add °I PERMIT APPLICATION NOTES C C'O e Valise of Constructiea— In all cases, a valve ofeons/mclion amount should be entered by the applicant. This tae will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every xery permit issued shall become invalid uoless'the work on the site authorized by such permit is commenced within 130 days ager is issdance,,or lithe yank anti nri2ed an the she by such permit is suspended or abandoned kr a period of ISO {lays after the time the work is cid. The Fire Marshal is authorized to grant, in .. writing, one or more extensions of time, for periods not more than I*0 days each. The extension shall be requested in writing and justifiable Cause defied_ I HEREBY CERTIFY THAT I HAVE REi13 4ND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZE AGENT: Signature: Print Name: Cr( s'VI t2 m bJlaid Plan Pert App doc PAID AQ'' 1 2019 Date: 3t311/1 TUKWILFa� (d/76C'T 8112/14 TFD FP Fonu 8' SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** `I 1 King Co. Assessor's Tax No.:�.�t0� 9,T) Site Address: f '1.0(\CRIkk1(' i��\1 Suite Number: Floor: Tenant Namer-cYX i. L ti 1 New Tenant? ❑ - Yes ❑ - No Property Owner's Name:', -Aa X i C.tjr;_ (--aelpk-. Mailing Address:t'l) Iihr) ` U) x ocict 42013 City CONTACT PERSON -if there are questions about the submittal. State Zip Name } '64):b 3'(D ul vu a Day Telephone(X) Q)tj1SS – Company Name:Cn 1CP X aialk. ` 11 I(lki,-, !'c,J p�v�5 Mailing Address: \-1 l Ave • 6 CUJ QQ J KM- cat 311 - City State Zip E-mail Address I ► ► . . i% ► ll.J. .1 I : A I C/C) Fax Number: ontractor's City of Tukwi �/�y NICET III number: Business License number: fJ ` UJ fl Z Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $1--V `` Scope of Work (please provide detailed information):t1 �(� G�`(,1Y M <'SU rsri / `Ir j 4 v�v�prov.�rnP��l c Accun (R d12N1_1?_6 • PERMIT APPLICATION NOTES Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR itlINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Pm BUILDING OWle OR AUTHORIZED AGENT: `•�( 2 2019 Signature , —, hi(il.� 'V�t&_ mg /� FIRE Date: 61.211"1 , TUKWILA Print Namc%, 1(i) , (�(� kK �1kX Day Telephone( (j ) WIS -39/14 0 Pian Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: '� �p SCD( A-1 &0.4444-r Mu 4(� Suite Number: t 0, Floor: Tenant Name: T vct v Property Owner's Name: Vi -6 e Mailing Address: "113ki.-) V CONTACT PERSON -if there are questions about the submittal. Name:N 1;,S11 C\ Cm rd -c' Company Name: Mailing Address: New Tenant? ❑ - Yes ❑ - No City Id kr 98160—° °0 State Zip Day Telephone: 7S3--11 Ht LO2 y) -1e ra.iAcUte 53Sc-e..A geA+f-Le City ate t E-mail Address: C j r`'t ja"0 "qrC • GOW� Fax Number: ^(0 3 — "1 s Lf Contractor's City of Tukwila � Business License number: (� � ,_ ` � 3 O� NICET III number: Total number of new/relocated devices or sprinkler heads: ! Valuation of Project (contractor's bid price): $ 2 t 2w' 63 Scope of Work (please provide detailed information): —1- vim� PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. w� y?101 Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID BUILDING "OWNER OR AUTHORIZED AG NT: Signature:// V 1 A 14 2019 TUKWILA FIRE Print Name: (vi tAS N/1 Date: (Q1 (' 2c`l Day Telephone: 7,5 3 3 - 'l t Z 1 Plan Permit App.doc 8/22/14 TFD FP Form 8 e/f S ed l( • FILE COPY FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Blue C Sushi 468 Southcenter Mall Permit No.: 08-H-242 Date: Mayl 29, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Nozzle heights above appliances to be per manufacturers installation guidelines. • Install splash guards between fryers and ranges/charbroilers. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Trapper Sushi 468 Southcenter Mall Permit No.: 19-H-121 Date: June 17, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Nozzle heights above appliances to be per manufacturers installation guidelines. • Fryers shall be installed with at least a 16 inch space between the fryer and surface flames from adjacent cooking equipment or a minimum 8 inch high steel or tempered glass baffle plate shall be installed between the appliances. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust system whenever cooking operations occur. The activation of the exhaust system shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. • If code compliant fire alarm notification is not already in place in the kitchen, a minimum 110 candela horn/strobe shall be installed above the kitchen hood suppression system manual pull station at a height of 80 inches above the floor. • A separate fire alarm permit from the Tukwila Fire Department is required for all fire alarm work. • The suppression system manual pull station shall be located no closer than 10 ft. and no farther than 20 ft. from the cooking equipment and be placed at a height of 42 to 48 inches above the floor. • The inside lower edge of the hood shall overhang or extend a horizontal distance of not less than 6 inches beyond the edge of the top horizontal surface of the appliance on all open sides. The vertical distance between the front lower lip of the hood and such surface shall not exceed 4 feet. • If cooking appliances are wheeled, the appliance wheels shall be set in tracks permanently mounted to the floor to ensure appliance is returned to original location if moved for cleaning or maintenance. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Trapper Sushi 468 Southcenter Parkway Permit No.: /7 -S -p77 Date: April 10, 2019 Reviewer: Kevin Varao Fire Prevention Specialist (206) 575-4407 option # 2 (Inspection Requests) (253) 856-4476 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. Customer BLUE C SUSHI 468 SOUTHCENTER 71 I KIWILA, WA 54478 GUARDIAN SECURITY L 1FE AND PROPERTY PROTECT!€).N Project BLUE C SUSHI Project # 54492 List of Materials Vendor Guardian Security Systems Inc 1743 1st Ave. South Seattle, WA 98134 Phone #: (206)622-6545 Fax #: (206)628-4990 Type of Equipment FIRE ALARM Date: 5/07/08 Item Qty. Manuf. Model Description Unit Pri Total Price 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) \ 19) 20) 21) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) 33) 34) 35) 36) 37) 38) 39) 40) 41) 42) 43) 44) 45) 46) 47) / \ 48) 49) - 50) Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens Siemens PAD -3 AD2-P HTRI-D HTRI-R SET CW,W SET-MC-CW,W ZR-MC-CW,W ZR-MC-W,W HFP-11 HFP-11-relay AD2-P Power Supply for Strobes With Standby** Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 Supervised Addressable Input Module Supervised Addressable Output Relay Module Interior Audible Speaker Annunciator Combination Speaker/Strobe Interior Visual Strobe Annunciator Interior Visual Strobe Annunciator Photoelectric Smoke Detector w/DB-11 Base Photoelectric Smoke Detector w/HR relay base Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 ** PAD -3 with BT -33 Conduit Systems: All smoke removal and detection and control devices in an approved metallic raceway and all devices in conduit per Standard • E 3 [] Without Ccrrments Ai- Po: d s y' Pu: T, _ Uttar 0 ti i FUKWILA FIRE DEPARTM1011. if Please call: 575.4402 :_J l; and give this job d No. 08—N -a` -r . ° r J exact awLiress for shut. 1 r ., .in or re,tJration approval. i nese plans t" T`• • Tui-'.1ita Fire Preventio7, . curt, �t city standards. oriss + a.dop`.od stand, add;. •• js artcr ,ds d. . ;.. •e eSpproval. , Final accc^`Z -•cc _ c' '.o "e d tsst and inspection by , The Tukvw;Ia I=1rc P .: '.' r i ureau. 1Date: By: AA^��% 1 SECTION IX - APPENDIX UL EX. 3470 ULC CEx747 Page 9-1 10-1-02 REV. 5 SYSTEM SELECTION GUIDE NOTE: System options do not cover all conceivable variations. They are listed here as a general guideline to show the most common type arrangement for multiple systems, Based on certain system designs utilizing manifolding, non-manifolding, 3 -tank systems, etc., other tank/cartridge combinations can be designed. The combinations below are based on 11 flow, 3.0 gallon tanks and 5 flow, 1.5 gallon tanks. More competitive designs may be available by utilizing 12 flow and 6 flow systems when appropriate. 'Total Tank Type of Carbon Dioxide Nitrogen Flow No.* Quantity System Type of Hardware Cartridge Required Cartridge Required 1-5 1 Single 1.5 Gal. Reg. Release 101-10 (423439) LT 20-R (423429) 6-11 1 Single 3.0 Gal. Reg. Release 101-20 (423441) LT 30-R (423435) 12-16 2 Double 1.5 Gal. Reg. Release 101-30 (423443) Double (423493) 3.0 Gal. Additional Tank 17-22 2 Double 3.0 Gal. Reg. Release 101-30 (423443)** Double (423493) 3.0 Gal. Additional Tank 23-33 3 Multiple 3.0 Gal. Reg. Release 101-20 (423441) LT 30-R (423435) 3.0 Gal. Reg. Actuator 101-30 (423443)*** LT -A-101-30 (423491) 3.0 Gal. Additional Tank 23-27 3 Multiple 1.5 Gal. Reg. Release 101-10 (423439) LT 20-R (423429) (Optional) 3.0 Gal. Reg. Actuator 101-30 (423443)*** LT -A-101-30 (423491) 3.0 Gal. Additional Tank 28-33 3 Multiple 3.0 Gal. Reg. Release N/A Double (423493) (Optional) (2) 3.0 Gal. Additional Tanks 34-38 4 Multiple 1.5 Gal. Reg. Release 101-10 (423439) LT 20-R (423435) 3.0 Gal. Reg. Actuator N/A LT -A-101-30 (423491) Double 3.0 Gal. Tank Box 34-38 4 Multiple 1.5 Gal. Reg. Release 101-30 (423443) Double (423493) (Optional) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)`** LT -A-101-30 (423491) 3.0 Gal. Additional Tank 39-44 4 Multiple 3.0 Gal. Reg. Release 101-20 (423441) LT 30-R (423435) 3.0 gal. Reg. Actuator N/A LT -A-101-30 (423491) Double 3.0 Gal. Tank Box 39-44 4 Multiple 3.0 Gal. Reg. Release 101-36 (423443)** (Optional) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)*** 3.0 Gal. Additional Tank Double (423493) LT -A-101-30 (423491) 45-49 5 Multiple 1.5 Gal. Reg. Release 101-30 (423443) Double (423493) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator N/A LT -A-101-30 (423491) Double 3.0 Gal. Tank Box 45-49 5 Multiple 1.5 Gal. Reg. Release 101-10 (423439) (Optional) 3.0 Gal. Reg. Actuator 101-30 (423443)*** 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)*** 3.0 Gal. Additional Tank • Based on 5 flow numbers for a 1.5 gal. system and 11 flow numbers fora 3.0 gal. system. •• If tanks ere manitdded, only a "double tank' nitrogen cartridge (Part No. 423493) can be used. ••' If tanks are manlfotded, either an LT -A-101-30 nitrogen cartridge (Part No. 423491) ora double tank cartridge (Part No. 423493) can be used. LT 20-R (423429) LT -A-101-30 (423491) LT -A-101-30 (423491) --NCO I Fire & Security. R-102•RESTAURANT SYSTEM NOZZLE COVERAGE SUMMARY SHEET ANSUL. R-102 OVERLAPPING PROTECTION The '245•nozzie, Part No. 419340, Is the only approved nozzle for overlapping (zone) protection. Appliance Type Maximum.Cooking Hazard Fryer 34 in. (864 mm) Deep x 5.8 sq. ft. (.54 sq. m) Griddle • 30 In. (762 mm) Deep x Unlimited Length Range 28 in. (711 mm) Deep x Unlimited Length Wok, Maximum 30 in. (762 mm) Diameter x 8 In. (203 mm) Deep Wok, Minimum11 in. (279 mm) Diameter x 3 in. (76 mm) Deep Braising Pan/lilt Skillet' 34 in. (864 mm) Deep x Unlimited Length Lava Rock Char -Broiler 32 in. (813 mm) Deep x Unlimited Length Charcoal Broiler 32 in. (813 mm) Deep x Unlimited Length (41n. (102 mm) Maximum Fuel Depth) Mesquite Wood Broiler 32 in. (813 mm) Delp x Unlimited Length (12 in. (305 mm) Maximum Fuel Depth) Gas Radiant Char -Broiler 36 in. (914 mm) Deep x Unlimited Length • Electric Char -Broiler 34 In. (864 mm) Deep x Unlimited Length "I See FJgure 1 for nozzle location. COVER MUST NOT 1.--1110-8 (0-15 cm) INTERFERE WITHEDGE OF DISCHARGE 1 T PATTERN I • ZONE CENTER UNE 40-45 IN. (1.1.1 m) TYCO SAFETY PRODUCTS. ONE STANTON STREET. MARI ETTE. WI 54143.2542 715.735-7411 Form No. F-2005010 Ce006 Maul Inoorpaated , Ufa h U.S.A./ i • Duct Plenum Nozzle Type Flow Points Width (In) Max. Side Length (In) . Max. Side Nozzle Placement (See Manual for More Detail) Min. Height (In) Max. Height (In) .. 0.: , . W : :t r_ 4 r:. .-. 12b�-,, '0In..-6.1n:4111 . 1 enu s., Perpendicular Protection Single Bank g 1 W/1100 1 48 .. .... ...,.. 2W +1100 48 Yar See Manual for more detail 1 ... ,,. See Manual for more detail Horizontal Protection V Bank 2 x 1N 2 48 >135 120 0 in. - 6 in. from end of plenum - 2 4 . Horizontal Protection V Sank 1W/1100 1 48 72 0'in. • 6 in. from end of plenum 1/3 the height of filter Perpendicular Protection V Bank 1W/1100 1 48 48 See Manual for more detail 1 20 R-102 OVERLAPPING PROTECTION The '245•nozzie, Part No. 419340, Is the only approved nozzle for overlapping (zone) protection. Appliance Type Maximum.Cooking Hazard Fryer 34 in. (864 mm) Deep x 5.8 sq. ft. (.54 sq. m) Griddle • 30 In. (762 mm) Deep x Unlimited Length Range 28 in. (711 mm) Deep x Unlimited Length Wok, Maximum 30 in. (762 mm) Diameter x 8 In. (203 mm) Deep Wok, Minimum11 in. (279 mm) Diameter x 3 in. (76 mm) Deep Braising Pan/lilt Skillet' 34 in. (864 mm) Deep x Unlimited Length Lava Rock Char -Broiler 32 in. (813 mm) Deep x Unlimited Length Charcoal Broiler 32 in. (813 mm) Deep x Unlimited Length (41n. (102 mm) Maximum Fuel Depth) Mesquite Wood Broiler 32 in. (813 mm) Delp x Unlimited Length (12 in. (305 mm) Maximum Fuel Depth) Gas Radiant Char -Broiler 36 in. (914 mm) Deep x Unlimited Length • Electric Char -Broiler 34 In. (864 mm) Deep x Unlimited Length "I See FJgure 1 for nozzle location. COVER MUST NOT 1.--1110-8 (0-15 cm) INTERFERE WITHEDGE OF DISCHARGE 1 T PATTERN I • ZONE CENTER UNE 40-45 IN. (1.1.1 m) TYCO SAFETY PRODUCTS. ONE STANTON STREET. MARI ETTE. WI 54143.2542 715.735-7411 Form No. F-2005010 Ce006 Maul Inoorpaated , Ufa h U.S.A./ i • Duct Nozzle Type Flow Points Perimeter (In) Diameter (In) No*zie Placement (See Manual . • for More Detail) Dyct Length (In) Single Nozzle,l flow nozzle '2.:. 1100 • • 1 50 16 See Manual for more detail Unlimited ... _ . t�tr�zzle f(o iv nortle .1 2W .. f:.. i,. :'i• ' C. .. «.3 .85-,,. .. :�_tlw ..n...;.,n � ,,�t3� Makivat., or more detail �..: , '. , Unlirriited ,„ MultipleNozzle .. .... ...,.. 2W +1100 .... 3 135 48 ... ,,. See Manual for more detail F,.....,,.. G;. e. Unlimited Multiple 2W Nozzle 2W — >135 >135 See Manual for more detail Unlimited R-102 OVERLAPPING PROTECTION The '245•nozzie, Part No. 419340, Is the only approved nozzle for overlapping (zone) protection. Appliance Type Maximum.Cooking Hazard Fryer 34 in. (864 mm) Deep x 5.8 sq. ft. (.54 sq. m) Griddle • 30 In. (762 mm) Deep x Unlimited Length Range 28 in. (711 mm) Deep x Unlimited Length Wok, Maximum 30 in. (762 mm) Diameter x 8 In. (203 mm) Deep Wok, Minimum11 in. (279 mm) Diameter x 3 in. (76 mm) Deep Braising Pan/lilt Skillet' 34 in. (864 mm) Deep x Unlimited Length Lava Rock Char -Broiler 32 in. (813 mm) Deep x Unlimited Length Charcoal Broiler 32 in. (813 mm) Deep x Unlimited Length (41n. (102 mm) Maximum Fuel Depth) Mesquite Wood Broiler 32 in. (813 mm) Delp x Unlimited Length (12 in. (305 mm) Maximum Fuel Depth) Gas Radiant Char -Broiler 36 in. (914 mm) Deep x Unlimited Length • Electric Char -Broiler 34 In. (864 mm) Deep x Unlimited Length "I See FJgure 1 for nozzle location. COVER MUST NOT 1.--1110-8 (0-15 cm) INTERFERE WITHEDGE OF DISCHARGE 1 T PATTERN I • ZONE CENTER UNE 40-45 IN. (1.1.1 m) TYCO SAFETY PRODUCTS. ONE STANTON STREET. MARI ETTE. WI 54143.2542 715.735-7411 Form No. F-2005010 Ce006 Maul Inoorpaated , Ufa h U.S.A./ i • tLICO / Fire & Security R-102 RESTAURANT SYSTEM NOZZLE COVERAGE SUMMARY SHEET a ANSUI.I Appliance Nozzle Type Flow 'Points Width (In) Max. Side Length , (In) Max. Side Multiple Nozzle wo/Drip Board Area Sq. In. Multiple Nozzle w/Drip Board Area Sq. In. Min. Nozzle Ht. (in):.: Max. Nozzle Ht. (in) Fryers without drip boards Split or No Split Vat 230 2 14 15 — — 27 47 245 2 14 ' 15 — . — 20 . 27 Fryers without drip boards Non -Split Vat MLY) 290 2 19.5 19 . — — 13 4 - • • 16 , 3N 3 19.5 194 — • — 21 34 3N 3 18 ' 18 — — 25 35 • Fryers with drip boards Split or No Split Vat' 230 2 14 21 210 294 27 47 245 2 14 21 210 294 20 27 Mors 1 with drip boards' • Non -Split Vat (ONLY) 290 2 19.5 25 3/8 370.5 495 13 . 16 ON _3 - 19.5 25 318 3.70.5 495 • 21 34 2 3N • 3 18 , 27 314 324. 497 . . 25 35 lilt Skilet/Braising Pan' Coverage Exception limitation are based on fryer Tilt SIdllets and Braising sizes including the drip boards. may exceed the maximum of 6.sq. ft. 'j Without back shelf With back shelf Without back shelf With back shelf •• 1N 1 12 32 —• — 30 ' 40 ' - 1°F t 12 28 — — 30 50 1F - • 1 12 20 - . - :. 40 48'i • tai I , ; 24 ' . 28 — - .. 40 501 260 2 • . 24 32— — 30 4 260 . 2 12 32 — — 30 40 2 x 290 4 36 28 — — 15 20 Griddle : . I 1N/1NSS 1 36 30 . . — — 35 40 290 2• 30t 24 —• — 30 50 260 2 48 30 — — I 30 50 290 2 48 30 — — 20 90 . 2120 2 48 30 — — 10 i 20 Chain Broiler' (Ovehead Protection). 2x 1W 2 34 30 • — — 10 26 Chain Broiler (Horizontal Protection) 2x 1N 2 • '31 ' 43 — . . — , Front edge; above the chain 1 - 3 in. Char Broiler. Gas -Radiant Electric Lava -Rock Natural Charcoal' Lava -Rock or Natural Charcoal' Wood Fueled' 1N/1 NSS 1 • 24 36 ' I — • — . 15 < 40 1N/1NSS 1 20 34 — — 20 50 1h1/1 NSS 1 13 24 — — 18' ; 35 1N/1NSS 1 12 ' 24 — — 18 40 3N 3 24 30 — — 14 ' ' 40 3N 3 24 30 — — 14 40 Upright Broiler 2 x 1/2N '1 30 32.5 Front edge; above the grate Salamander Broiler Internal Chamber 2 x 1/2N 1 30 ' 32.5 — 1N 1 16 29 —. •— — — 1 N nozzle location to be on the vodka) edge 6 to 12 in. in front and 0 to 12 In. above the top of broiler 1N 1 16 . 29 , - - 6-12 In. above either end Wdc 3.75 to 8 Inches deep l 3 to 6 inches deep 260 2 14 in. to 30 in. diameter — — • 35 45 1N/1NSS 1 11 in. to 24 in. diameter —• — • 30 40 +. • Formultiple nozzle protection of single fryers, see detailed information on pages4-10 to 4-11 of manual. ..a$Nfigure 1 for nozzle location, Wawa— chain broiler exhaust opening —12 in. x 12 In. (31 cm x 31 cm); and not less than 60% of Internal broiler size. 44 h maximum fuel de ! 04 416 as) maximum fuel depth. ....r Cn_ Z008 Tukwila Fire FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Blue C Sushi 468 Southcenter Mall Permit No.: 08-S-133 Date: April 24, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. Western States Fire Protection Co. 7102 180x` Ave NE Suite A-105 Redmond, WA 98052 (425) 881-0100 (425) 881-3030 FAX Fire Protection Systems Design *Fabrication •Installation Commercial •Industrial *Residential *Institutional Special Hazards *High Tech *Defense *Hangars Retrofit •Service •Inspection *Maintenance April 17, 2008 Alan Metzler Tukwila Fire Department 444 Andover Park East Tukwila, WA 98188 RE: Blue C Sushi --Westfield Southcenter Mall Response to:Tauzon Engineering Fire Sprinkler Review Letter 1. Dry Sprinkler will be installed in accordance with the 2007 NFPA 13. 2. A minimum of 6'-0" between sprinklers will be maintained. A. South of gridline K.5 and 7.6, two pendent sprinklers are dimensioned 5' -10th" apart. This is a cut length with take outs. Actual Center to Center dimension is 6'-0". B. South gridline L and 7.6, two upright sprinklers are dimensioned 5'-9'/2" apart. West head is obstructed by beam. C. South of gridline N and 7.6, two upright sprinklers are approximately 4'-9V2". West head is obstructed by beam 3. Washington State fire sprinklers certificate stamp will be provided. 4. The North arrow will be rotated to point to the left of the page. 5. Product data will be included with submittal to the City Of Tukwila. Adam Kantner Project Manager Western States Fire Protection, Inc. Dallas, TX *Austin, TX *Houston, TX •Albuquerque, NM *Decatur, IL •Denver, CO *Duluth, MN •Kansas City, KS Tac VPaae NV •Minnaannlic MN •Phrtaniv A7 •Portland (lR •Ranid City ST) •Salt T.alre City TIT •SOattiO WA •St. T.nnis MO [1r JI J 14 March 2008 Martin Sokulski Western States Fire Protection 7102 -180th Ave NE, Suite A-105 Redmond, WA 98052 RE: Westfield Mall — Blue C Sushi (Space #468) Independent Third Party Review — Fire Sprinkler System Dear Martin: Tuazon Engineering, PLLC 4322 NE r Street Renton, WA 98059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. It appears the sprinkler system shown is part of Zone T1 fed from the West Riser Room. The following was reviewed: • Fire Sprinkler Drawings — Sheet FP1 dated 4/11/08 • Hydraulic Calculations dated 4/10/08 The documents were reviewed for compliance with the 2007 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. I have found the fire sprinkler design to be acceptable subject to the following comments: 1. Ensure dry sprinklers are installed in accordance with 2007 NFPA 13 Para 8.4.10 such that the clearance around the sprinkler barrel is sealed and the barrel is of sufficient length to prevent freezing of the wet piping. 2. A minimum of 6 feet between sprinklers should be maintained unless baffles or different ceiling heights will exist. The following locations should be reviewed and corrected as needed: a. South of gridline K.5 and 7.6, two pendent sprinklers are dimensioned 5'-10Y2 " apart. b. South gridline L and 7.6, two upright sprinklers are dimensioned 5'-9%" apart. c. Sound of gridline N and 7.6, two upright sprinklers are approximately 4'-9'/ " apart. 3. Provide Washington State fire sprinkler certificate of competency stamp on the drawing and calculations. 4. The north arrow should be rotated to point to the left of the page. 5. Include applicable product data with the permit submittal to the City of Tukwila. A resubmittal to Tuazon Engineering is not required provided the above are resolved to the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or ericRtuazon.com with any questions regarding this review. • Westfield Mall — Blue C Sushi (#468) Third Party Review — Fire Sprinkler Systems 14 April 2008 Page 2 Respectfully, TUAZON ENGINEERING, PLLC Buz p Eric P. Tuazon, PE Fire Protection Engineer C.tnp, Fps,2C08 Rq R,20CB. Westar S.les tfeb&c CSiaMl4aµm Wazon sPcl'.r reuew clot 4ydruIic Summary Job Number: KS0303 Report Description: Ordinary Group II Job Job Number KS0303 Design Engineer Adam Kanter Job Name BLUE C SUSHI State Certification/License Number WESTESF136QF Address I 468 Southcentner Mall AHJ CITY OF TUKWILA Address 2 Job Site Southcentner Mall Suite # 468 Cy Tukwila State Wa Zip Code 98188 Drawing Name FP-1.cad Most Demanding SennWar Data 5.6 K -Factor 26.00 at 21.556 Occupancy Ordinary Group II Hose Allowance At Source 250.00 Density 0.20gpm/ft2 Area of Application 1077.00ft2 (Actual 1077.58ft2) Additional Hose Supplies Node Flow(gpm) Total Hose Streams 250.00 System Flow Demand 345.35 Total Water Required (Including Hose Allowance) 595.35 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Crowd 17.51 between nodes 290 and 288 Maximum Velocity Under Ground 1.30 between nodes 1 and 33 Volume capacity of Wet Pipes 1784.67gal Volume capacity of Dry Pipes 0.76ft3 Number Of Sprinlders Calculated 12 Coverage Per Spnnider 130.00ft2 suPP Node Hose Flow (gpm) Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required (psi) Safety Margin (Psi) 1 250.00 140.000 20.000 1 10900.00 139.446 I 595.35 49.331 90.115 , •. p.00ft ....................................... Contractor Number KS0303 Contact Name Adam Kantner Contact Title Project Manager Contractor Name Western States Fire Protection Phone 425.881.0100 Extension Address 1 7102 180th Ave Ne, Suite A-105 FAX 485.736.9032 Address 2 city Redmond State WA Zip Code 98052 Web -Site ke© M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00:20AM Page 1 Job Number: KS0303 Report Description: Ordinary Group II Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) Sprinkler 109 31.53 26.00 5.6 31.695 Sprinkler 112 31.66 26.00 5.6 31.973 Sprinkler 102 26.56 26.00 5.6 22.492 Sprinkler 103 27.08 26.00 5.6 23.391 Sprinkler 107 28.18 26.00 5.6 25.330 Sprinkler 110 31.58 26.00 5.6 31.799 i Sprinkler 101 26.00 26.00 5.6 21.556 Sprinkler 104 27.15 26.00 5.6 23.509 Sprinkler 105 27.24 26.00 5.6 23.667 Sprinkler 106 27.79 26.00 5.6 24.627 Sprinkler 108 28.92 26.00 5.6 26.677 Sprinkler 111 31.64 26.00 _ 5.6 31.923 ;'% Most Demanding Sprinkler Data M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00:42AM Page 2 Job Number: KS0303 Report Description: Ordinary Group 11 Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 19 1-11 42.144 33 5-8 BFP(-4.500) 45.046 161 1-11 P0(37 -8Y2) 42.084 203 13-3 fT(25-0) 36.739 232 13-3 P0(5-0) 35.580 235 13-3 P0(5-0) 35.878 242 13-3 2P0(8-0) 36.425 258 13-3 P0(5-0) 25.545 259 13-3 P0(5-0) 25.702 260 13-3 P0(5-0) 26.667 261 13-3 P0(5-0) 28.749 264 13-3 P0(5-0) 35.692 274 13-3 2P0(8-0) 36.236 285 13-3 P0(5-0) 26.794 286 13-3 P0(5-0) 26.964 287 13-3 P0(5-0) 27.995 288 13-3 P0(5-0) 30.196 290 13-3 2P0(8-0) 36.182 292 13-3 P0(5-0) 35.825 1 -4-0 S 49.331 345.35 109 16-5% Spr(-31.695) 31.695 31.53 112 16-5% Spr(-31.973) 31.973 31.66 102 16-5Y2 Spr(-22.492) 22.492 26.56 103 16-5% Spr(-23.391) 23.391 27.08 107 16-5% Spr(-25.330) 25.330 28.18 110 16-5Yz Spr(-31.799) 31.799 31.58 101 16-9Y2 Spr(-21.556) 21.556 26.00 104 16-5Yz Spr(-23.509) 23.509 27.15 105 16-5Yz Spr(-23.667) 23.667 27.24 106 16-514 Spr(-24.627) 24.627 27.79 108 16-514 Spr(-26.677) 26.677 28.92 111 16-514 Spr(-31.923) 31.923 31.64 © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00:45A M Page 3 Job Number: KS0303 Report Description: Ordinary Group 11 Pipe Type A(� © Diameter Flow Velocity HWC Friction Loss Length Eq. Length Total Length Pressure Summary Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings es Route 1 SP 1.049 0=26.00 9.65 C=120 0.211434 4-6Y2 Pf 2.445 101 16-9% q=26.00 K=5.6 21.556 Spr(-21.556) 7-0 Pe 1.544 258 13-3 25.545 E(2-0), PO(5-0) 11-6Yz Pv BL 1.610 Q=26.00 4.10 C=120 0.026249 6-0 Pf 0.157 258 13-3 25.545 Pe 0.000 259 13-3 25.702 6-0 Pv BL 1.610 0=52.56 8.28 C=120 0.096517 10-0 Pf 0.965 259 13-3 25.702 Pe 260 13-3 26.667 10-0 Pv BL 1.610 0=79.64 12.55 C=120 0.208223 10-0 Pf 2.082 260 13-3 26.667 Pe 261 13-3 28.749 10-0 Pv BL 1.610 Q=107.83 16.99 C=120 0.364715 8-6Yz Pf 7.486 261 13-3 28.749 12-0 Pe 274 13-3 36.236 2LtE(2-0), PO(8-0) 20-6Yz Pv CM 4.260 0=282.15 6.35 C=120 0.018916 10-0 Pf 0.189 274 13-3 36.236 Pe 242 13-3 36.425 10-0 Pv CM 4.260 0=345.35 7.77 C=120 0.027492 11-5 Pf 0.314 242 13-3 36.425 Pe 0.000 203 13-3 36.739 11-5 Pv CM 6.357 0=345.35 3.49 C=120 0.003914 16-11 Pf 0.435 203 13-3 36.739 94-3Y2 Pe 4.910 161 1-11 42.084 fE(12-7), CV(40-3), GV(3-9Yz), 111-2Yz Pv PO(37-8'/z) FM 8.329 Q=345.35 2.03 C=120 0.001050 24-8Y2 Pf 0.060 161 1-11 42.084 32-0 Pe 0.000 19 1-11 42.144 2fE(16-0) 56-81A Pv MS 10.020 0=345.35 1.41 C=120 0.000427 20-2 Pf 4.537 19 1-11 42.144 67-0 Pe -1.635 33 5-8 45.046 3LtE(16-0), BV(19-0), BFP(-4.500) 87-2 Pv UG 10.400 Q=345.35 1.30 C=140 0.000268 231-1 Pf 0.085 33 5-8 45.046 86-1 Pe 4.200 1 -4-0 49.331 2LtE(25-6), E(35-1), S 317-2 Pv = Route 2 SP 1.049 0=26.56 9.86 C=120 0.219917 3-3 Pf 1.810 102 16-5Yz q=26.56 K=5.6 22.492 Spr(-22.492) 5-0 Pe 1.400 259 13-3 25.702 P0(5-0) 8-3 Pv =• Route 3 SP 1.049 0=27.08 10.05 C=120 0.228030 3-3 Pf 1.876 103 16-5% q=27.08 K=5.6 23.391 Spr(-23.391) 5-0 Pe 1.400 260 13-3 26.667 P0(5-0) 8-3 Pv 6r Route 4 SP 1.049 0=27.15 10.08 C=120 0.229091 3-3 Pf 1.885 104 16-5Yz q=27.15 K=5.6 23.509 Spr(-23.509) 5-0 Pe 1.400 285 13-3 26.794 P0(5-0) 8-3 Pv BL 1.610 0=27.15 4.28 C=120 0.028441 6-0 Pf 0.170 285 13-3 26.794 Pe 286 13-3 26.964 6-0 Pv BL 1.610 0=54.40 8.57 C=120 0.102848 10-0Y2 Pf 1.031 286 13-3 26.964 Pe 287 13-3 27.995 10-0Y%Pv BL 1.610 0=82.19 12.95 C=120 0.220689 9-11% Pf 2.202 287 13-3 27.995 Pe 288 13-3 30.196 9-11% Pv BL 1.610 Q=111.11 17.51 C=120 0.385523 7-6% Pf 5.986 288 13-3 30.196 8-0 Pe 290 13-3 36.182 P0(8-0) 15-6Yz Pv CM 4.260 Q=142.75 3.21 C=120 0.005363 10-0 Pf 0.054 290 13-3 36.182 Pe 274 13-3 36.236 10-0 Pv = Route 5 SP 1.049 Q=27.24 10.11 C=120 0.230518 3-3 Pf 1.897 105 16-5Yz q=27.24 K=5.6 23.667 Spr(-23.667) 5-0 Pe 1.400 286 13-3 26.964 P0(5-0) 8-3 Pv = Route 6 SP 1.049 0=27.79 10.32 C=120 0.239153 3-3 Pf 1.968 106 16-5Yz q=27.79 K=5.6 24.627 Spr(-24.627) 5-0 Pe 1.400 287 13-3 27.995 P0(5-0) 8-3 Pv 0/ Route 7 M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11: 00:46A M Page 4 Job Number: KS0303 Report Description: Ordinary Group II Diameter Flow Velocity HWC Friction Loss Pipe Type Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream SP 1.049 Q=28.18 10.46 C=120 0.245460 Length Eq. Length Total Length Pressure Summary 107 16-51A q=28.18 261 13-3 K=5.6 25.330 Spr(-25.330) 28.749 PO(5-0) 3-3 5-0 8-3 Pf 2.020 Pe 1.400 Pv ▪ Route 8 SP 1.049 Q=28.92 10.74 C=120 0.257517 108 16-51A q=28.92 K=5.6 26.677 Spr(-26.677) 288 13-3 30.196 P0(5-0) 3-3 5-0 8-3 Pf 2.119 Pe 1.400 Pv 08. Route 9 SP 1.049 Q=31.53 11.70 C=120 0.302024 109 16-5% q=31.53 K=5.6 31.695 Spr(-31.695) 232 13-3 35.580 P0(5-0) 3-3 5-0 8-3 Pf 2.485 Pe 1.400 Pv BL 1.610 Q=31.53 4.97 C=120 0.037495 232 13-3 35.580 242 13-3 36.425 2LtE(2-0), PO(8-0) 10-6% 12-0 22-6% Pf 0.845 Pe Pv ear Route 10 SP 1.049 Q=31.58 11.72 C=120 0.302938 110 16-5% q=31.58 K=5.6 31.799 Spr(-31.799) 264 13-3 35.692 P0(5-0) 3-3 5-0 8-3 Pf 2.493 Pe 1.400 Pv BL 1.610 Q=31.58 4.98 C=120 0.037609 264 13-3 35.692 274 13-3 36.236 2LtE(2-0), PO(8-0) 2-5% 12-0 14-5'% Pf 0.544 Pe Pv imp Route 11 SP 1.049 Q=31.64 11.75 C=120 0.304032 111 16-5% q=31.64 K=5.6 31.923 Spr(-31.923) 292 13-3 35.825 P0(5-0) 3-3 5-0 8-3 Pf 2.502 Pe 1.400 Pv BL 1.610 Q=31.64 4.99 C=120 0.037744 292 13-3 290 13-3 35.825 36.182 PO(8-0) 1-5% 8-0 9-5%. Pf 0.358 Pe Pv ▪ Route 12 SP 1.049 Q=31.66 11.75 C=120 0.304469 112 16-5% q=31.66 235 13-3 K=5.6 31.973 Spr(-31.973) 35.878 PO(5-0) 3-3 5-0 8-3 Pf 2.506 Pe 1.400 Pv BL 1.610 Q=31.66 4.99 C=120 0.037799 235 13-3 242 13-3 35.878 36.425 2LtE(2-0), PO(8-0) 2-5% 12-0 14-5% Pf 0.547 Pe Pv 0 0jWgn#> '::fie ql�.: n9.:.....:.:....:....::....:..:...:.::..:.95.x.:.............. ( Schedule 40 Steel Pipe Inside Diameter Actual Inside Diameter 4.87 = Factor G:1l'•'' ''dolt ':: Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 (X, ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00:46A M Page 5 Job Number: KS0303 Report Description: Ordinary Group 11 Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Upstream AO BL CM DN DR DY FM FR MS OR RN SP ST UG Elevation Discharge K -Factor Pt Pn Fittings Length Eq. Length Total Length Pressure Summary .......................: Arm -Over Branch Line Cross Main Drain Drop Dynamic Feed Main Feed Riser Miscellaneous Outrigger Riser Nipple Sprig Stand Pipe Underground �F1JS:Ei Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve De1V Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11 Y° Elbow Ee2 22%° Elbow f Flow Device FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap (M� © M.E.P.CAD, Inc. AutoSPRINKO VR5 v5.2.6 04/22/2008 11:00:46A M Page 6 • Job Number: KS0303 Report Description: Ordinary Group II Supply at Node 1 Pressure, psi in 8 A 8 c(n S 8 8 cCO 11111. 1t 11111111 1 111 tittt11111.111i1 1 11111 1111111.111111111.ttttt1tttt1 1 1111 1 111111111 1 11 Static Pressure 140.000 595.35 445.35 with hose @ 49.331 streams S stem demand curve 10900.00 @ 20.000- 1111111111111111111 11 1 1 1 1 1 1111111111 1 11111 1 11 1 1 11 f 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11111 I I I I I 1111 U 71002200 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.446 @ 595.35 System Demand 345.35 @ 49.331 System Demand (Including Hose Allowance) 595.35 @ 49.331 [by © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00:49A M Page 7 Job Number: KS0303 Report Description: Ordinary Group 11 [Uy ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/22/2008 11:00: 50A M Page 8 Type 1 KITCHEN HOOD 12"W x 24"L 2w 13'6" HOOD A Fire 6 Gia 22 -Flo PULL STATION (10-20ft from hood) GAS VALVE El ®® • o®® i Steamer Range -Shelf Griddle (36"L x 24"D) (12"L x 24"D) (36"L x 24"D) 1 Table Fryer Fryer Fryer (18"L x 24"D) (16"L x 21"D) (16"L x 21"D) (16"L x 21"D) PAID jI,Jt! 14 201Y T UKWILA Fi F 3ev Customer:TRAPPER SUSHI - R1, 468 Southcenter Mall Systems: Ansul R102 - 6 Gallon Fire System, 22 Flow Point Capacity Proposal Date: 4/26/2019 Drawn by: Joshua Gualco Approved by: 15 TOTAL FLOW POINTS FOR SYSTEM Li Without Comments As Noted In Red Per The Attached Letter These plans have been eviewed by The Tukwila Fire Prevention Bureau fnr conformance with current City standards, P,C i 1s is 3Libject to errors and omissions which r..a: violations of adopted standards and The responsibility for the adequacy of des!c i Totally with the designer. Additions, c elelio. ; f. .Y.,.i:;',0 s to these drawings aft this date Mil T.of u tFce and will reouire resus bmitiai ofr' 4: ;; a'� ;:lie rr:'tip : 9ubsepuerl 3ppro1,.. Final accepts; ce 1, sub, =ct oto 1 ?ti test and inspection o. The Tukwila Hre Preven k: � iureau. Date: s -//ice// 9 T F� 375:iO7 ill givia this F3v : A Permit No. and e: pct address for shut- down hutdarn or relor3UUof approvvie SHEET NUMBER SHEET TITLE Fl H 1 FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON FA -01 SYSTEM INFONATION FA -02 TYPICAL WI SING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS FA -04 FIRE ALA SYSTEM PLA\ SHEET INDEX ADD 2 NEW CEILING MOUNT SPEAKER/STROBES TO AN EXSITING FIRE ALARM SYSTEM SCOPE OF WORK WISE SCHEDULE A\ CO\DUIT FILL CHAT WIRE DESIGNATIIN SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 ' FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END EXPIRES 09/01/2020 FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION.. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNCANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MININUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 2 E E E E E E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER E POWER SUPPLY PAD -3 SIEMENS EXISTING 66" A.F.F. TO TOP FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2" EXTN CEILING ®E SMOKE DETECTOR (EXISTING) HFP-1 1 SIEMENS EXISTING CEILING ®E D DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS EXISTING VERIFY IN FIELD TSM DUCT DETECTOR E TEST SWITCH (EXISTING) TSM -1 SIEMENS EXISTING VERIFY IN FIELD HT -R INTERFACE MODULE E WITH RELAY (EXISTING) HTRI-R SIEMENS EXISTING VERIFY IN FIELD FIRE ALARM SLE STROBE (EXISTING) ZR -MC -W SIEMENS EXISTING CEILING SE FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING KH E KITCHEN HOOD (EXISTING) F.B.O. F.B.O. N/A VERIFY IN FIELD TENANT J -BOX F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N /A N/A N/A N/A NOT APPLICABLE N/A N /A N/A N/A SYMBOLS LEGEND r- II NORDSTROM 3 LEVELS 171,2755f iJ AYLN MADE h N4b?.STY1 CiFTS ,UO macys LEVELS T1-£ never ?=EPEE AcE'�%Ci,BE Dftriruoi _`_1 250,407sf TRAPPER'S SUSHI 468 PAnus sRrL_.,.:..s. K:) JC• P..Tenney • 3 LEVELS 276.468sf R. L._,,..:..,. aan :FESTA:.RAN PAM J FSTAARAN TIG FE1E SIJ. MZJ,/A'S RESTAURANT •C,A h BAR WIRE DESIGNATION GENERAL NOTES SITE PLAN PAID HAt 2 2019 TUKW l AF9RE c .v' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 04/30/19 _ z ccs 2 26 Qc�cI- U3 2 W O WM it (I) 21( EL QQ U) � co CCWry.�c IJ. LL 1-- J 4CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/30/19 BACKROUND PLAN PROVIDED BY: 10B NUMBER:45432- FA-01 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET °Q THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. PUCK OVER 3' WIDE: SAMPLE 1IJBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-601{Z DEDICATED EMERGENCY FROM EXISTING MAIN FACP C CABLE C' CABLE N LL 07: T 0 0 CI PAD -3 0 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 S B 0 0 3.6k E0L 0 0 (-) (+) (-) (+) HARD LID CEILING HARD LID SPEAKER SUPPORT TILE BRIDGE 2, NAC S4 NAC S3 NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N ;CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) STROBE SPEAKER (+) () C FROM PREVIOUS ADDRESSABLE DEVICE TBI 01010®®©0 ®®9 10 NO COM NC TO FAN SHUTDOWN EOLR 470 SWITCH + INPUT LED TSM -1 0 00 + TO NEXT ADDRESSABLE DEVICE TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) (-.) STROBE STROBE SPEAKER (-) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE cn O M O u) J Z NG AND MOUTN CC J U SCALE: NOT TO SCALE` DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/30/19 BACKROUND PLAN PROVIDED BY: .10B NUMBER:45432—Ij SHEET (� FA -02 J FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project:. TRAPPER'S SUSHI Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLY Date: April 30, 2019 Module/Device Qty Standby Total Standby Alarm Total Alarm (mA) (mA) (mA) (mA) Power Module 1 15 15 0 140 140 0 A:TOTAL FIRE ALARM POWER SUPPLY 15 140 B Auxiliary Device Current 0 0 C : Notification Appliance Load (Max. Total / mA) 0 D E F G H J K 1007 Total(A)= ` 15 Total(B)= CALCULATION 1147 Total current ratings of all devices in system (line A + line B + line C) 15 1147 Total current ratings converted to amperes (line D x .001) 0.015 1.147 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.0955451 Add lines G and I Total Standby and Alarm AH 0.4555451 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.54665412 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR). 7 *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP -HR *** Notification Appliance Circuit Detail PROJECT: TRAPPER'S SUSHI Panel: _ EXISTING BPS PAD -3 REMOTE POWER SUPPL Date: _ April 30, 2019 Wire Resistance 2.58 CURRENT TOTAL 1007.00 NEW 1 EX 4 EX 2 DEVIC SET -MC -CW @15cd SET -MC -CW @30cd SET -MC -CW @75cd SET -MC -CW @95cd ZR -MC -W @15cd 7 Total Wire Resistance R) Total Device Load, Amps (I) Voltage Drop ( E EOL Voltage 22.00 L*2)*(R/ft) :(Total Cct Load) (E=I*R). 24-E) 1007 1.99 1.01 2.00 22.00 (OLD BLUE C SUSHI POWER SUPPLY AND DEVICES ) FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project:TRAPPER'S SUSHI Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLY Date: April 30, 2019 Module/Device Qty Standby Total Standby Alarm Total Alarm (mA) (mA) (mA) (mA) Power Module 1 15 15 0 140 140 0 A TOTAL FIRE ALARM POWER SUPPLY 15 140 B Auxiliary Device Current 0 0 C . Notification Appliance Load (Max. Total / mA) 0 D E F G H K 469 Total(A)= . 15 Total(B)= CALCULATION 609 Total current ratings of all devices in system (line A + line B + line C) 15 609 Total current ratings converted to amperes (line D x .001) 0.015 0.609 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.0507297 Add lines G and I Total Standby and Alarm AH 0.4107297 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.49287564 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP -HR *** Notification Appliance Circuit Detail PROJECT: TRAPPER'S SUSHI Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPL Date: April 30, 2019 Wire Resistance 2.58 CURRENT TOTAL= 469.00 NEIN 1 SET -MC -CW @15cd SET -MC -CW @30cd SET -MC -CW @75cd SET -MC -CW @95cd ZR -MC -W @15cd EX DEVIC TOTAL Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E )... ._ EOL Voltage 400 0 0: 469 14 450 22.91 (WL*2)*(R/ft) (Total Cct Load) (E=I*R) 24 - E) 469 2.32 0.47 1.09 22.91 ( OLD MR. TUX POWER SUPPLY AND DEVICES ) CALCULATIONS EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved re) 4000' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS I Lu F-- < 04/30/19 .z =52 T Jo) v) 0 z 0�0 U) Wzz 161C CL2 ~ cc �d� ~ cr LL � 6ALE: NOT TO SCALE -\ DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/30/19 BACKROUND PLAN PROVIDED BY: �0B NUMBER: 45432-1) SHEET (� FA -03 7.6 0 ExISTING r 6 0 11111111411111111111111P11111111111111111111111141101111111111IIII i = a =II A /,, A 7, ,zl oz.z.452:4 30Cd (E) ELEC./STOR. 102 CC 30'-0' =0001 I= 1=111 =1111 1101 (EXISTIN) 111111111111111111111111111111111111111111111110111111IIIIIIIIIIIIIIIIIII111111111111111111111116111111111111111111111111111 J8111111111111111illi1iii1111111111111111111111111111111111111111114111111m11111111111111IIIIIiIIIIIIIIIIIIIIIII (E) OFFICE 103 I .1 1 4. I FIELD vERIFT 11+ an n (E) BACK—OF—HOUSE 1 101 75Cd VE /I t sj 1 1 1 j t I V I I ss j ! I ; Is ti I ;i 1`. 1 1 ! I I (E) COMMON EXIT 100 ==t m CORRIDOR EXIT CORRIDOR I 116 1 (E) ALCOVE 112 j 1 j DINING l 104 75Cd VE FOOD PREP. 1 113 el 1 'I 111.11 1'1! 1 111 I 1,1 L F — el -s I It fi s 1 I 1 1111III. I r 11 1c I 1 1 HT -R IE TSM DED E LJ I. (E) MEN ?‘—' _,_/- -* 50d I 114 1 [II ll . /--- r -1 i / r---—j)ii- 1 \ 1 I 1 ii c i I . i• WOMEN 115 • 44 M N) STORAGE 1.061 ' 1=911 =I CI =1 12 =I 111 =11 =2 CI =I • se 1:I sk4..fe*:+104....Gte, 5EE R COOLER • .gatititTM‘MITM!"..ttiWnZeireitSr.MM•ZNard.#. -------- ---------------------------- A II BAR 105 1 J OLD B I \ I DINING 107 UE C SUSHI i" C11=1111 C=111 II =El IS =1 El =11 11 L 151d 1 111 =I 0 =CI 111 111 0 =1 IN =II ,=I 1,1-I L _ I — — ITSMTE F El =1 I Sill \ -, I ...--- -1, il = I / 1 ,f)----- \.. \ _ 0-- / 1 = = Ei _77- I = — 30Cd „ I 4'1.2 •\,i I SERVER STN.11 111 / 75Cd VE 4J 1 / HOSTESS STN_ 12=111111111=10110111=101=1111191111=10 L DINING 1 110 1 l.j 1 111 1 75Cd VE 11 UU --TUX SHOP ENTRY I 108 h COUNTER91 DINING i10 CI =I = 0 =1111 D--- 0 101 CI= NO FIRE ALARM SYSTEM PLAN fis=a=0= = 0= =a EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I X IiIlliI. 1 ii .' i. . E i• 1 I 1 111 i I Iii1I I Ili 111 I, SHOP DRAWINGS il -1 li 11 DATE 04/30/19 C11=1111 C=111 II =El IS =1 El =11 11 L 151d 1 111 =I 0 =CI 111 111 0 =1 IN =II ,=I 1,1-I L _ I — — ITSMTE F El =1 I Sill \ -, I ...--- -1, il = I / 1 ,f)----- \.. \ _ 0-- / 1 = = Ei _77- I = — 30Cd „ I 4'1.2 •\,i I SERVER STN.11 111 / 75Cd VE 4J 1 / HOSTESS STN_ 12=111111111=10110111=101=1111191111=10 L DINING 1 110 1 l.j 1 111 1 75Cd VE 11 UU --TUX SHOP ENTRY I 108 h COUNTER91 DINING i10 CI =I = 0 =1111 D--- 0 101 CI= NO FIRE ALARM SYSTEM PLAN fis=a=0= = 0= =a EXPIRES 09/01/2020 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I X DESCRIPTION SHOP DRAWINGS DATE 04/30/19 2 <<<<< 0. 'ALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/30/19 BACKROUND PLAN PROVIDED BY: JsOB NUMBER:45432-1i SHEET FA -04 BLUE C SUSHI General Notes VICINITY MAP (Suite# 468) SCALE: NTS 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced In accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. Existing Zone T1 6" Main WEST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE 8.1 C 0 Existing Zone T1 6" Main C C Oa' o >A s1\ 4 c'o co ri 3-11. 3-13'h C 0.11; 1- M 1 a5 -10'h tf \ 1 LD CLG 10-0 A.F.F �. d1I_f �L ��h ryri, X to J v �Q 11/2‘..'.. , JQ 1 5°--61-1---° 10 0 i'-6'.5 • 7.11 & ��be C Tt rte 11 123 1/21 n rocs gm irm EnT 1:31 MI rat MI SE3 IZ21 �� •r�tT 07\ ,CLG 8-6 A.F.F so X5-11 f 13 ,�. 0- i NvC., •4 11 n 4h 1'h 7-5 COOKING HOOD KITCHEN �h Oa\O� !• ! Gtr iy 10-0 maEi;M I att-Ita 11121 MI ll 1'h C CLG 12-6 A.F.F y •134:. i =�kNfbO 5-9 4-11 CLG 17-6 A.F.F o'I kN 114 8-64h JQ 6-11• O �hh 1'h 258 rn 3-9 JQ ,1' N,5;3 2-21/2d ' 10-9 450 S -9'h '1(4 Wal In Coale' Blue C Sushi Remote Area: Retail # 468 's 1-b 6-0 fb, • ®c) -` ®® 1'h k JQ 3-8' u1J 10-0 OOk00 1 6-3'' v 0\4O, 11-0'/2 ^h /! CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 Ft' DENSITY .20 GPM / Ft' for 1130 Ft' SPRINKLER Reliable Model G4A ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER. SYSTEM REQUIRES: 345 GPM © 45.3 PSI ' At time of Design 17'-6" CLG: 28.75% AREA REDUCTION 4\A- 6-0 Ok 6-0'f { I 6-3' Ordinary Group II.0.20gpm/ft2 for 1077.00ft2 Il Existing T14" Main 6 0 FIRE SPRINKLER PLAN C 0- '',+F— 8-61A 6-9 • 5-2''A1 WI 4e -may`, ra 3 5 7 9 11 IEMI c 7.6 7 C 52 c TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD t CEILING TILE FIG. 809 SWIVEL SWAY BRACE FITTING laph FLEXHEAD DETAIL NOT TO SCALE 3J8' KWIK BOLT (2 IW EMBED LENGTH) FIG. 1000 "FAST CLAMP' SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NCH -THREADED BRACE PIPE FIG. 4A PIPE CLAMP FOR SWAY BRACE FIG. 908 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT 3/8' KWIK BOLT (2 IN' EMBED LENGTH) LATERAL BRANCHLINE RESTRAINT BRACE PIPE Thad NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III / EMT! Kw& Boll II 5 N1/ Dn7ledAnchor��T i 'G ' T/ L Bottom of Concrete to Center Line of Pipe Note on Plan Cut Rod Lgth Rounded to Nearest Inch Rod Coupling All Thread Rod Concrete Construction Swivel Ring Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE BLUE 0 SUSHI w z O Adam Kantner 2 v al N cu0 CONTRACTOR: SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE R3615 33 5.6 Upright Brass 155°F Reliable F1 FR SSU APPROVAL: CITY OF TUKWILA HYDRAULIC REFERENCE POINT 3 5.6 Pendent IAN Chrome 200°F Rel F1FR SSP Rec 2 5.6 Pendent Brass 200°F Rel F3 DR DRY HANGER SYMBOL BRANCHLINE RESTRAINT R3515 8 5.6 Pendent Chrome 155°F Rel F1 FR SSP Rec R5415 15 5.6 Pendent %' Chrome 155°F Rel G4A Concealed Total = 61 KS0303 Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE: 06/19/08 Western States Fire Protection Company 7102 180th AVE NE, STE {-105 - REDMOND, WA - 98052 Lic. #. WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/ DECATUR / DENVER /DULUTH/HOUSTON/KANSAS CITY LAS VEGAS /MIMIFAAPOLIS /PHOENIX/ PORTLAND /RAPID CITY/ST. PAUL /SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax: 425-881-3030 BLUE C SUSHI 468 Southcentner Mali Tukwila ,Wa 98188 FIRE SPRINKLER PLAN SHEE FP - OF 1 T 1 SHEET INDEX FIRE TUKWILA, W7' SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLAN '•��.'`r`r.. ••;:. is Without Comments 0 A. Noted In Red Per The Attached Letter nese plans ha17e -`y The TLlic ,ila Fire Prevention currentcittl icrs and of adopted for fthe atter r .qti re a approval. and inspection by The Tukwila; Fire Gi::lbcU. Date: 0 By: M TUKWILA FIRE DEPARTMENt. Please call: 575-4407 and give this job No. OA -F -1 and exact address for shut. Town or restoration approval: NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N _ SYMBOL DESCRIPTI❑N NUMBER ❑F CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART ... . NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE • DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 112" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END SH YSTE INGTO GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING. DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL., DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS :SUPERVISED: NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT: CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, . WIRE,; .FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CARE; FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CEfBERUS DIVISION. : 6. DETECTORS SHALL NOT BE MOUNTED, IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS.: PER NEPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RSPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE.: CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE: IDENTIFICATION. 41, 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES:., g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS,REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. • 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND. 760 OE NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN'' REFERENCE TO DEDICATED. BRANCH POWER SOURCES. 120vac POWER SHALL NOT :BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALES BE. MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS] WILL BE ON THE RECORD DRAWINGS SET. • 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF 'ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION _ FOR PROTECTION DURING CONSTRUCTION. _ DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT: CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE. CONTINUOUS, 'FREE: OE GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. : 18. ALL CABLES SHALL BE MARKED AS INDICATED : ;ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHAM BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES ,OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METAWC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME. CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED I II SYMBOLS LEGEND QUANTITY 1 1 4 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FRCP I • FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM SDD-C .. SIEMENS REMOTE ANNUNCIATOR PROVIDED 66" A.F.F. TO TOP BPS I REMOTE BOOSTER IEX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP : INTERFACE MODULE HTRI-R ® I' ; : THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE VATH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS DUCT DETECTOR LOCATION Am TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT vLABEL SCXE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE I FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH 1 0 0 GROUND_ u0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 0 HTRI—R 4110 STATUS LED (0 0 0 0 N.O. COM N.C. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE L NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING--- \ TUBE INLET SAMPLING—\ TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE ILIFAC POWER SONJRCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE f(+) STOP IF LAST DEVICE .(-) FROM XLS CONTROL PANEL OR .1(¢) PREVIOUS ADDRESSABLE DEVICE LB RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 mitt DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04 u F 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTION. IA AI TB1 6j AAA A 1 2 3 4 5 6 HCP TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END OF LINE DEVICE (3.6K 1/4W) 0 SUPERVISED:____' SWITCH GROUND --- - r i 0 0 HTRI—D STATUS LED OD 0 0 NOT USED 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 -TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL WEL Se4LEE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC A A A 0 MOO U. 0 0 0 PAD -3 0 • INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- -1 2+ 2- 2 NC C NO + - + - + - + - + - El Lam] 24K NAC -4 NAC -3 NAC -2 NAC -1 END OF:i' I LINE DEVICE 3.6K i/4W? UPERVISED SWITCHI FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE . DEVICE LOOP NOT USED REMOTE DEVICE LOOP OZ____ FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V` CABLE) 470 OHMS 1W1 EOL 0 A1TCE INPU TCM -1 O • • 0 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SC LE: NONE C (4 - STROBE) SPEAKER (STR❑BE—) EARTH GROUND ;a I --►(+)TO NEST DEVICE:OR }, >(-) STOP IF LAST DEVICE v (STR❑BE) SPEAKER SPEAKER/STROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80- AF.F. - r 4S DEEP BOX W/ 1 -1/2 - EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE TCI>'NEXT DEVJCE OR • END .E(F LINE TO ;;NEXT DEVICE; OR END :. C)! ' LINE • NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPT TEMPERA +32' F (O C TO 10tt F C }TUMIDITY: O- X RELATIVE HUMIDITY. NON -CONDENSING HFP-11 SMOKE DETECTOR --� -31- FROM PREVIOUS ADDRESSABLE DEVICE OR POIMER SOURCE DATA IN (-) DATA IN (-F) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WEN USED IN CONJINCTDON VAIN DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMDXE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICE > (—) DATA OUT (F) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING fa -1743 -IST -1 -AVE: SO;; SEATTLE, WASHINGTON co CJ RELEASE/REVISIONS SPEAKER SUPPORT TILE----\ BRIDGE DESCRIPTION LLI SQUARE DEEP BOX , WITH 1-1/2' EXTENSION N. SHOP DRAWINGS to in CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) JUNCTION BOX MOUNTED ON CEILING FLEX \ JUNCTI MOUNTED A CEILING S N BOX PPORT 03 CO 2 1§Z 0 cc 0 co ,-/zifjo 011 TO NEXT DEVICE I, CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI BACKROUND PLAN PROVIDED BY: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved -SHEET FA -02 { { 2S 2S,2V,D i ., $,i ----------------- 4 } EOL -S2 19.93V Irufrrr�sr✓rrrrr�sfrr/ {% X • '14C,'") . 7F/..c 4l)'- • .R i iii �".Y.:.�rrrrr.•sz� { { D 1- 0 \kb.”, BLUE C SUSHI WESTFIELD SOUTIICENTER MALL SCALE 118"=V FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATI❑N SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. SIEMANS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER.. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT, Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved a 0 0 ct �CALE: 1/8" =1 ' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: .1.0B NUMBER:54492 % SHEET FA -03 j 1; 1, 1;• 11: r ':1 4.7 t is ! • .•, SYSTEM CALCULATIONS 0 - NORTH 1 11 11 1j\ :11 n. 1, / 1 • • .•••• \ .••• o 0 6 c, 14 / • 1 t .;" : . BLUE ,C SUSHI , .• •. • ' I BLUE C SUSHI .' i;,.: ,' :•,:, . , SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations : ' SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations . . • . . . DESCRIPTION SHOP DRAWINGS ' DATE on o in ... in .-.Hi • i;'). Current Load: <<<< Standby: Alarm: ' ,'; ,i•i:, Current Load: • Standby: :Alarm: , : • • Device Type Qty Amps Total Amps Total Device, Type . Qty Amps Total - Amps Total 43. Main System Board 1 0.03 0.03 0.030 0.030 •:-; : MainSystem Board 1 0.03 : 0.03 0.030 0.030 SET-MC@15CD.._._., . ,k-t-rode6615 111 - 1, 0.064 0.064 SET -MC @15CD SET -MC @30CD 1 0.064 . 0.064 1 0.098 0.098 0.098 0.098 Ef-ICiie- dfgo- 6 3 0.175 0.525 SET -MC @110CD - -SET-HMC-Cti15CD ' - SET-HMC-C@135CD _______________________ 0 233 . SET -MC @75CD 3 0.175 0.525 0.318 SET:I40 @110CD ' . . , SET-I-IMC-Cgn5CD .. . .. _ __ SET-HMC-C@135CD . _L • SEt-I4M-C-C@I -8-5CD ' ---- - - - '-' ZR -MQ @15C,D . _ ZR-iio ta6bb 0.233 0.318 0.318 SET-HMC-C@185CD ziri-fc di eco . 0.445 , . , . 0.318 . .• 4 0.064 0.256 0.445 24:ka--@i665 - ------- . 0.098 ,.,. 4 0.064.. , 0.256 FiEi:;---- ,_ ____ . 0.0015 , 0.098 , 0.03 Amps , 0.973 Amps HCP ,:i ; . . : 0.0015 - ;' Current Load: :; , 0.03 Amps For 24 Hours = 0.720 Amp -hours :..,,i ;.',1•.. • , 0Standby ..i 03 Amps 0 973 Amps ' . .4 H.,. Alarm Current .Load: . '0.973 Amps For 5 Minutes= 0.082 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours .. : . - ' " 25% Derating= 1.002 Amp -hours':,' Alarm Current Load: 0.973 Amps For 5 Minutes= 0.082 Amp -hours 4--.., . . ; Total System Current Load 1.002 Amp -hours '';..• !.;!i!... ' 25% Derating= . 1.002 Amp -hours ;,.:. r. • ;,,: 1: il • , •.•i.1,; • i: Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULAT • ON BLUE C SUSHI WESTFIEDSOUTHCITERMALL SCALE 1132'4 EOL -S2 21 EOL -S1 C 75 C 75 15 15 c 30 30 15 15 c 75 NOP 2S,2V,D BPS A BOX FACP I , ••• •• • •`• • .•-• •• • • •-• Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MAL- L Panel: !BLUE C SUSHI- . , ;wire Resistance 162 : Date: May 8, 2008 , S1 CURRENT TOTAL= 977 CIRCUIT:S1 I . ; ,; 44 ; QTY : Device Type ; 1 , arm Currentl Alarm Total 1 Wire Size ; ire Length, ! Voltage at EOL ; Circuit Total i '', , •,- , 0 ;SET -MC @15CD 64'0 0; • • 1 SET -MC ©30CD 1 SET-MC@75CD 981 - 981 1-T Total Wire Resistance ( R ) 0.81 (WL*2)*(R/ft) 175; 1751 ; Total Device Load, Amps (1) 0740, _14 0 SET -MC @110CD 2331 01 0 • :SET-HMC-C9115CD 318 tl: 1. Voltage Drop ( E 0.32 ) (Total Cct Load) ; _,. . I 0 ISET-HMC-C@177CD1. 445i ' 01 0 SET -HMC @135CD 0 SET -HMC @185CD 2 iZ-MC@15CD 0 1 Z -MC 930CD 0 iSET-MC-CW©110CD DEVICES= ,t1 ; . EOL Voltage 1. 20.0844 41 (E=T_ I * R) 318's 01 4451 Oi1 (20.4 - E) 641 1281 981 .2331 TOTAL mA=1 01 ; - OS 4011 12 250 1 20.07519 401 . , CIRCUIT.; S2 1 . , ; ; s ; , QTY ; Device Type ;Alarm Current; Alarm Total 1 VVire Size 1 VVire Length i Voltage at EOL ; Circuit Total -;', i 440 . SET -MC ©15615 641 oi _, . , :. ;,. !Total Wire Resistance ( R ) ; 0.82' , ' 2 SET-MC@75CD i 1751 350'----- ,(WL*2)*(R/ft) 0.58; !Total Device Load, Amps (1) i 7 1 SET -MC @3666 981 99-; 0 ,SET -MC ©110CD 2331 _0 SET-HMC-C@115CD 318 0 . i . Voltage Drop ( E ) 0.47 0 sr-Typic@177cD 445 (E= I * R) 1 0 !SET-HMC@135do 1 . 3181 0 , , -,4 . , -i. EOL\/ 0 2 1SET-HMC @185CD ; 4451 01 .., 2O4 - Eg)e 19.93 Z-MC@15CD 64 128 ; i-MC@30CD , ' O 981 , ; 0 SET-MC-CW@110CD 1 2331 :1 - , . , 1 01 (Total Cct Load) DEVICES=i 5'°ii TAL MA=1. 5761 12 1 • • - -Notification Appliance PROJECT: WESTFIELD.SOUTHCENTER MALL p 1J 4 • ---- . 2- 53 :. 19.9278412/ 576 Circuit Detail • . , .._...._„____.._ Panel: i PANDA EXPRESS ' , : !'t: i Wire Resistance 2.58 . : :::: , . , . . -- ' 41. r- : Date: !May 8, 2008 ; ill, CURRENT TOTAL=19 CIRCUIT:!SPEAKER CIRCUIT , QTY Device Type Current Alarm Total Wire Size 1 re Length ; Voltage at EOL Circuit Total • - 5 , 70.7Y 1 /8 9i . I Total Wire Resistance (_R ) 1.82 , ; ! 0 ,-- • 0 , ...•._ ____________ _________.........___ • ._. __... _________.....,• _______ ; ( WL* 2 ) * (R/ft). •,_ ......„ . 0 ;0 0 iTotal Devide Load, Amps (1) 0.01 I: i- • • .._ ; _; .._, 0 ,i . -----0 00 i II , - (Total Cct Load) 0 0L 0 Vo4ge-Drop (E) 0.02 : I, (E= I* R) 0 . 'OL . ' Of - EOL Voltage - - .,..._.,.. ____ ...._..... ,......... - ... •.. .. __.., .. . . L I 0 , 01 .- 0i i ii - i _ , ' I (20.4 - E) .. 20.38i 0 , • - : Ol 01 . f I , 0 i 0 : ' 016T DE1 44- ; ; 1 VICES=;'.5 . i L....,n.„1, _ ..__..•.___i4i_l___________....___. ....io_._..eie._.5...i{1 .4, 352 _ . . ; .• Tot _ . r-- -•• EX -,t • cu LU tr;) CO O• 1743 .IST AVE. SO., SEATTLE, WASHINGTON TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NVI DESCRIPTION SHOP DRAWINGS DATE on o in ... in < <<<< • CC w z w 0 0 w >°- CO KALE: 1/8'1=1' DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZAN I DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: ..1.0B NUMBER:54492 SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved. FA 04 .441 443 -43 •Ji BLUE C SUSHI General Notes VICINITY MAP (Suite# 468) SCALE: 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. C C C Existing Zone T1 6" Main c _ -;:rte,...; ,.:•, -, r, `.'�..re._�-.�,. 0 • 10-534 CLG 100 A.F.F 0.111 1E2 ICI EC 1E2 CC LZ1 CLG 8 • A.F. COOKING HOOD CZ rt x•. • ta . `e .t CLG 17-6 A.F.F 0 TYPICAL FLEXABLE SPRINKLER CONNECTION:'. FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXBEAD DETAIL TAIL NOT TO SCALE 39' KWIK BOLT (21W EMBED LENGTH) FIG.1000 "FAST CLAMP SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS law NON -THREADED BRACE PIPE 318' MIK BOLT R IAP EMBED LENGTH) FIG. OM NO -THREAD SWIVEL SWAY BRACE ATTACHMENT FIG. 4A PIPE CLAMP FOR SWAY BRACE LATERAL BRANCHLINE RESTRAINT BRACE PIPE e NON -THREADED BRACE PIPE LATERAL BRANCHLIKE RESTRAINT NOT TO SCALE Wal in Coale Hanger No. 07C HILTI Kwik Bolt III V1 TICE Ordinary Group II.0.20gpm/ft2 for 1077.00ft2 Existing T1 4" Main Rod Coupling Concrete Construction AA Thread Rod Weld stamps must be inspected before pipe is hung. Do not paint piping priAr to hydrostatic test approval. Swivel Ring Note on Plan: Hanger Number and W Dimension -Existing Zone T1 6" Main WEST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE FILE COPC �f TU# kgIL4 FIRE DEPARTM N Please call: 575-4407 and give this job No. W3—&-/33 end exact address for shuts ti own or restoration approval; HANGER DETAIL NOT TO SCALE Blue C Sushi Remote Area: Retail # 468 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY ctAss ORD HAZARD 11 MAX COVERAGE per HEAD 130 FF DENSITY .20 GPM / Ft' for 1130 Ft' SPRINKLER Reliable Model G4A ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 345 GPM © 45.3 PSI ' At time of Design 17'-6" CLG.=28.75% AREA REDUCTION K5 Without Comments AsNotedlnRed Per The Attached Letter i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is eubiewt to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void thi-s.acceptance and will require a resubmittal of revised drawings for subsequent approval. i Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: Y—� �. By: 41 •1 1 3 FIRE SPRINKLER PLAN 118"=1' 0 SYMBOL LEGEND 2 -WAY EARTHQUAKE BRACE REVISIONS DESCRIPTION DATE SYM. SIN QTY. R3615 33 5.6 Upright 3 5.6 Pendent 2 5.6 Pendent 4 -WAY EARTHQUAKE BRACE HYDRAULIC REFERENCE POINT HANGER SYMBOL BRANCHLINE RESTRAINT Sprinkler Legend K SPRAY ORIF. FIN. TEMP. %Z' Brass Chrome Brass rn 2. 008!Pm 0 R3515 22 • 5.6 Pendent Total = 60 155°F 200°F 200°F Chrome 155°F MFR./MODEL Reliable F1 FR SSU Rel F1FR SSP Rec Rel F3 DR DRY Rel F1FR SSP Rec APPROVAL: cm' OF TUKWILA CONT. NO.: KS0303 DRAWN BY: Adam Kantner SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 04/23/08 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/DECATUR/DENVER/DULUTH/HOUSTON/KANSAS CITU IAS VEGAS rM8eE:JPOLIS/PHOENIX/PORTLAND /RAPID CITY/ ST. PAUL/SALT LAKE CITY/SEATTLE Phone: 425-881-0100 Fax 425-881-3030 BLUE C SUSHI 468 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER PLAN k'i a Fire SHEET 31 13C3" '-3 /2' VERIFY A009" 3'-31/2' VERIFY .77 1u tIt 0 RELOCATE (E) FIXTURE IF NECESSARY EXISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DUJGS /SCHEDULES L 1 EXISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DWGSJSCHEDULES { 1 17 2rt NO CEILING ABOVE WALK N COOLER - 3 TYP SEE KEC D1L 6 •4 1 � I FELE VER fV \ \ 1 I I 0 1 } J Y 1 1' U 0 /r CP n i f 4 i ' x,1 A3 1 t 5'-O' 11- 5'-6' li 744 11 11 EXIST'G. CEILING TO REMAIN THIS AREA, VERIFY NEW FINISHES W/ MF DWGS (REMOVE EXIST'G. LIGHT FIX- TURES, INSTALL NEW FIXTURES AS 61-1OWN 4 SCHEDULED) ' N % iv `_ —0 ti .,,i4 _ + R• 5 k� , a {{ Li _+ ` • JI CD 4 OD 1 ! , 'F 1 • P +s 3 ' 1 ti i 1 ilio '1 I r -.1a- p { : 1 I.i r i F.11 ' } i 25'-1' a 7'-O' AFF. BULKHEAD W c 1 _ NEW 6' 20 GA CEILIN -AMING m 16' OC W �, 1A � 74 '41 EXISTING CEILING/ (ETR) LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DWGSJSCHEDULES • • (ETR) « I -1 i (ETR) a 7 A3 1 a.• r • I 4441 , 11 6, e 'I, • R 1 ; , r.L} 1 ,. • / :41 ML , 1• t )! ATC,743 - (E) ' i t; ADJ 'CEILING 4 ;i':ta r + 1 4;' ,t 1=P1 D lv� R '4) ,P 11. sossismismosissosigpis NEW (3ULK-IEAD 1'-0' APP., IIS , •1'• is .. V' iK>X i y t,vR �' 1 —r--•—t_-.fs'e S, • I/ A , 1 Lh 1 4 /8 GYP. BR CEI ING - WALK IN GOOLE 10'-0' 101-0' 6'-O I0' -O' ,f .`L "--N:XISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DUJGS /SCHEDULES FACE OF SOFFIT TO ALIGN W/ FACE OF COUNTER I EELOUJ EXISTING CEILING/ L'GHTING TO REMAIN, VERIFY FINISHES W/ MF DWGS./66-1EDULES IREPLACIZE, 101-4N1 ig 4k49 5 =l EXPOSED TO STRUCTURE w / 6'-0' PENDANT ,h FROM GLAZING, Tr' K./ e:// E' ;01, 101-01 SEATING/EQUIP. SHOWN !BELOW FOR REFERENCE EI FROM GLAZING Or r .49 • IL ct PENDANT' FROM GLAZING I I if,- I 11.1/.. I r- :1 4-- '-2 1/2 IL_ -01 FlexHead Sprinkler Drop - Corrugated stainless steel hcse with stainless steel bral Adiu, table Hub Multi Port Bracket EXISTING MERCANTILE TENANT SPACE FLEXHEAD Flexhead -Commercial ceiling Unit T -Bar Ceiling Installation Model #2024,2036,2048,2060,2072 • REIMER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C—CLAMP WITH SET SCREW 3/8' ALL TNREAD REID PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL TEELOX MECHANICAL BRANCH CONNECTOR SIZE A 1-1/4 x 3/4 2 x 1/2 2 x 3/4 2-1/2 x 3/4 • 2 2-1/16 2-1/8 2 2-1/16 2-1/8 2-5/16 2-3/8 2-7/16 2-9/16 2-11/16 2-3/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-13/16 1-13/16 1-13/16 2-1/16 2-1/8 2-1/8 1-3/16 1-3116 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 NO soaal cols% • TUKWILA FIRE DEPARTMENT Plena ca4206-575-4107 and giv.2. this Fire Permit No. and for st-N.it- Design per NFPA 13 — Ordinary Hazard 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions • rA—PL4r: 04:9 puGET. SOIJND "9RE PREVENTION DEPT • 8 Add Reliable Model G5-56 Quick Response 165° Concealed Pendents % x • 1 — Add Globe Model GL5636 Quick Response Dry Pendent % x % im cust-nrioATia OF II FIRE PROTECTION SPRINKLER SYSTE 1 1 • John Thomas DeMartino 9794 -1091 -CG Level 3 Crown Fire Protecaon, Inc ile- 1801-13 422 Reflected Ceiling Plandwg Date/TIme January 10, 2019 5-29 PM Scale 1..48 Xrere 0. 10 ,All concepts, designs, arrangements, and clata indicated on these documents are the prc developed for use on, and in connection with the specified proJect. None of such Idea' any person, firm, or corporation for any purpose whatsoever without permission vf G A. Miller A oterissill CROWN FIRE PROTECTION INCORPORATED PO BOX 12113 MLL CREEK, WASHINGTON 98082-0113 PH (425) 481-7669 Trapper Sushi 468 Southcenter Parkway Tukwi1a, WA 98188 • • • • 1 • 0 111 • mo. Atm c\1 nxiALAARE DATE y-214,1 DRAWN J/G, SCALE 7. t '-101/2' ' . 6'-0' _ - I ' 6'-o' '. �I'-lo In ' .• r , _ • sI - n'" li". r }{ '. R .{ air 3r s t' /• i.`•.. JPi M� s `y..30' -O' R . ' . ' R :> ♦ . sz ' r._,..1...../ i �, J�� �,,: ! 1 T ,I i i� 1 • ., , .. � , , ' " i N { 0.43' L 4'-2 1 -----l1 1-4'.,211/2'— I. t414 I/2`-- -1 4'-4 1/21.-7-12'-0' j 10'-0' 101-0' 6'-O I0' -O' ,f .`L "--N:XISTING CEILING/ LIGHTING TO REMAIN, VERIFY FINISHES W/ MF DUJGS /SCHEDULES FACE OF SOFFIT TO ALIGN W/ FACE OF COUNTER I EELOUJ EXISTING CEILING/ L'GHTING TO REMAIN, VERIFY FINISHES W/ MF DWGS./66-1EDULES IREPLACIZE, 101-4N1 ig 4k49 5 =l EXPOSED TO STRUCTURE w / 6'-0' PENDANT ,h FROM GLAZING, Tr' K./ e:// E' ;01, 101-01 SEATING/EQUIP. SHOWN !BELOW FOR REFERENCE EI FROM GLAZING Or r .49 • IL ct PENDANT' FROM GLAZING I I if,- I 11.1/.. I r- :1 4-- '-2 1/2 IL_ -01 FlexHead Sprinkler Drop - Corrugated stainless steel hcse with stainless steel bral Adiu, table Hub Multi Port Bracket EXISTING MERCANTILE TENANT SPACE FLEXHEAD Flexhead -Commercial ceiling Unit T -Bar Ceiling Installation Model #2024,2036,2048,2060,2072 • REIMER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C—CLAMP WITH SET SCREW 3/8' ALL TNREAD REID PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL TEELOX MECHANICAL BRANCH CONNECTOR SIZE A 1-1/4 x 3/4 2 x 1/2 2 x 3/4 2-1/2 x 3/4 • 2 2-1/16 2-1/8 2 2-1/16 2-1/8 2-5/16 2-3/8 2-7/16 2-9/16 2-11/16 2-3/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-13/16 1-13/16 1-13/16 2-1/16 2-1/8 2-1/8 1-3/16 1-3116 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 NO soaal cols% • TUKWILA FIRE DEPARTMENT Plena ca4206-575-4107 and giv.2. this Fire Permit No. and for st-N.it- Design per NFPA 13 — Ordinary Hazard 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions • rA—PL4r: 04:9 puGET. SOIJND "9RE PREVENTION DEPT • 8 Add Reliable Model G5-56 Quick Response 165° Concealed Pendents % x • 1 — Add Globe Model GL5636 Quick Response Dry Pendent % x % im cust-nrioATia OF II FIRE PROTECTION SPRINKLER SYSTE 1 1 • John Thomas DeMartino 9794 -1091 -CG Level 3 Crown Fire Protecaon, Inc ile- 1801-13 422 Reflected Ceiling Plandwg Date/TIme January 10, 2019 5-29 PM Scale 1..48 Xrere 0. 10 ,All concepts, designs, arrangements, and clata indicated on these documents are the prc developed for use on, and in connection with the specified proJect. None of such Idea' any person, firm, or corporation for any purpose whatsoever without permission vf G A. Miller A oterissill CROWN FIRE PROTECTION INCORPORATED PO BOX 12113 MLL CREEK, WASHINGTON 98082-0113 PH (425) 481-7669 Trapper Sushi 468 Southcenter Parkway Tukwi1a, WA 98188 • • • • 1 • 0 111 • mo. Atm c\1 nxiALAARE DATE y-214,1 DRAWN J/G, SCALE