Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 506 SOUTHCENTER MALL - STARBUCKS COFFEE - PERMITS AND PLANS
506 SOUTHCENTER MALL ASSOCIATED PERMITS 12-F-228 12-S-219 IFZNAM SITE LOCATION l2-F.Zza CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 1lKing Co. Assessor's Tax No.:���, g�) ,-/Site Address: 1Q SCA.)&\C JV\ �' lCli Suite Number: Floor: V1' al....JW"'t- Tenant Name: Property Owner's Name: q..)4/`QI.6 �w Mailing Address: \ , O 1 \\,A \To L' \\i ` 1'U' ' CONTACT PERSON -if there are questions about the submittal. Name: KARINA VELIZ New Tenant? Yes ❑ - No Company Name: GUARDIAN SECURITY SYSTEMS, INC Mailing Address: 1743 — 1ST AVE S E-mail Address: kveliz@guardiansecurity.com CA (O2 City " State Zip Day Telephone: 206-734-6276 x229 City SEATTLE, WA 98134 State Zip Fax Number: 206-341-9928 Valuation of Project (contractor's bid price): $ / Scope of Work (please provide detailed information): .liw V � �,iu �I lft(.5 A A/ t C . PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING y WNER OR AUTHRIZED AGENT: Signature: Print Name: f(i, Je-1 Date: ,()/(61 /1,2/ Day TelephonerOL,C 2)C ( ) ?C7 Plan Permit App.doc 5/14/10 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 02470010 Site Address: 506 Southcenter Mall Blvd Suite Number: Floor: 1 Tenant Name: Starbucks New Tenant? ❑ - Yes X - No Property Owner's Name: Westfield, LLC Mailing Address: 2800 Southcenter Seattle, WA 98188 CONTACT PERSON -if there are questions about the submittal. Name: Martin Sokulski Day Telephone: (425) 881-0100 Company Name: Western States Fire Protection Mailing Address: 14690 NE 95th Street, Unit 101 E-mail Address: martin.sokulski@wsfp.us Redmond WA 98052 City Fax Number: (425) 881-3030 State Zip Valuation of Project (contractor's bid price): $ 3500 Scope of Work (please provide detailed information): space. Relocate and plug sprinkler heads to meet requirements of new tenant PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER OR : U HORIZED AGENT: Signature: Print Name: Martin Sokulski Day Telephone: (425) 881-0100 Date: FO/2 /I 2 Plan Permit App doc 5/14/10 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Starbucks 506 Southcenter Mall Permit No.: 12-S-219 Date: October 4, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). r • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON g Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which Co not authorize violations of adopted standards and ordinances. The responsTbility for the adequacy of design rests tote: with the designer. Add -tions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /0 By: 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented % to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. _/-2F-' and exact address for shut- down or restoration approval. SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FIRE ALARM SYSTEM PLAN SHEET INDEX WIRE SCHEDULE AND CONDUIT FILL CHART SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DETECTOR P 1 (PHOTO -ADDRESSABLE) DB1 1BASE SIEMENS 4S DEEP W/ 1G RING CEILING ®D DUCT DETECTOR TSM DUCT DETECTOR TEST SWITCH AD2-P W/ SIEMENS DUCT HOUSING HFP-11 GET. TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD Ell FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS ( C<�:4 kOvi SEARS macys STARBUCKS 506 WIRE DESIGNATION GENERAL NOTES SITE PLAN JCPenney PAID CCT -92012 TUKWILA FIRE cc ,zaD v 1:44 cc (75 o' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: WIRE DESIGNATIIN SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.0. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.0. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DETECTOR P 1 (PHOTO -ADDRESSABLE) DB1 1BASE SIEMENS 4S DEEP W/ 1G RING CEILING ®D DUCT DETECTOR TSM DUCT DETECTOR TEST SWITCH AD2-P W/ SIEMENS DUCT HOUSING HFP-11 GET. TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD Ell FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS ( C<�:4 kOvi SEARS macys STARBUCKS 506 WIRE DESIGNATION GENERAL NOTES SITE PLAN JCPenney PAID CCT -92012 TUKWILA FIRE cc ,zaD v 1:44 cc (75 o' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 DESCRIPTION SHOP DRAWINGS DATE 10/05/12 2 ««< Z 0 0 Z W >•1 (1) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/05/12 BACKROUND PLAN PROVIDED BY: Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved \0B NUMBER: 55554 SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60 Q DEDICATED EMERGENCY l NOTE: FOR ADd110NAL SPEC61CAB0NS SEE PRCOUCT DOCUIENTADOIL *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC ISOLAIVEGRDUNDIAN2 TO NEXT ADDRESSABLE �+ DEVICE STOP IF LAST DEVICE - FROM XLS C@ITROL PANEL (+ OR PREVIWS ADDRESSABLE DEVICE O 0 It 0 0 HTRI—R 0 O o NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0000 0 PAD -3 00 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 (-) (+) SPARE SPARE SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PNRWITH SHIELD #18 FPLIFPLR RED (JACKET) *CONTACT RAI1NGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O O '1 4 o 0 HTRI—R _ / O GROUND `LN\`,,___- (+)>TO NEXT DEVICE OR O 0 (-) (-) > STOP IF LAST DEVICE DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/EL.EC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) + u HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END DF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN TEMPERATU E: +32' F (0' C) TO 100"F (338' C) HUMIDITY: )-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —\ -4-FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE / STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 i 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL z Li, z 02cc z 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE CV \ 0 0 0 Zco co O CD 10 Z r<i) cc 0 wzz CO >0g, cc < -- Cs) CC LO LL }— �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/05/12 BACKROUND PLAN PROVIDED BY: 'OB NUMBER: 55554 1 C SHEET FA -02 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved \ J = F Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps XIStING:$1810Na. xten er`Patie • CU CiattentLOadir.'1-. ndby: : i• Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 al -MC -CW ©15CD 9 0.0875 ZH-MC-CW ©30CD 7 0.131 al -MC -CW @75CD 5 0.222 •ZH-MC-CW @95CD 2 0.292 0.584 Z1 -1 -HMC -CW ©135CD 0.371 ZR -MC -CW ©15CD 11 0.069 0.759 ZR -MC -W ©15CD 0.064 0.03 Amps 1.373 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.373 Amps For 5 Minutes= 0.115 Amp -hours 25% Derating= 1.044 Amp -hours Total System Current Load: 1.044 Amp -hours 12VDC 7.1AH Notification Appliance Circuit Detail PROJECT: Panel: Date: STARBUCKS EXISTING PAD -3 BPS October 8, 2012 i Wire Resistance 2.58 CURRENT TOTAL= 575.00 .,.,...,.. .„.. Zi -MC -CW @iscd 87i 0: - - 213 -MC -CW .@30ed - - 131- ' 131 . .. _...,.....•.,. ..• 2 7}1 -MC -CW @75cd 222; 444 ,•••,,,-.f..,•.-, ."'.^• •'.•"•,••.T ,....i,,r,),••••....,{" . } .4.- ,,,,.....,. +.< ,.. ....,,* '' •',/ 23 -1 -MC -CIN @96ed - . - 292 ' 0 .._ . _. .• •.,..,..........• jai-MC-cw 0135cd 371 0! 7R -MC -CW @16cd. - 69 DEVICES 3 TOTAL_ mA= 575! 1 I Total Wire Resistance ( R ) Total Device iii;lic cOati, Amps (1) 1 Noltage Drop ( E ) Voiiiige 14 285 : 23.15; 575 :( WL* 2 )*(R/ft) 1.47 (Total Cct Load). :0.58 (E= I * R) 0.85. 24E) 23.15 co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS SYSTEM CALCULATIONS TO NEAREST EXISTING s s EFAw-EOL POWER SUPPLY Si S1-2 S1-2 S1-3 30cd 75cd 75cd TO NEAREST EXISTING DATA LOOP D D,I I HT -RI 21-4 I TSM I FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS DATE 10/05/12 2 <<<<< CC 0 LU z w co .1 z co -185 Z CO 5z E:2 cco 0 2 VII 1E6 w zz ca fr, t51 4=t cc F- o co w crLoD LL H z z 0 —J 0 w >- (i) CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/05/12 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM \JOB NUMBER: 55554 I. SHEET Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FA -03 23'-23/4" TO NEAREST D EXISTING DATA c LOOP TO NEAREST EXISTING POWER SUPPLY o: EXIT S1-1 3Ocd D6 4'-111/2" 3'-11/2"I Workroom 0411 HT-R1 \ \/ �\ 0002 s6 Sales Backbar EOL S1 S1-3 75cd Ll S1-2 �1 75cd j :i 2'-6" 12'- 0" FIRE ALARM SYSTEM PLAN Mall Corridor<> FIELD VERIFY DIMENSION OF BUILD OUT FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: (..) m 0 DESCRIPTION SHOP DRAWINGS DATE N to 0 0 z aaaaa Zco co O_i� � �rn cc w0 zwz W = CO CC > 0v) ctt I— CC c!)Qo- UJ CC LO H 4-CALE: 1 /4"=1 '0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/05/12 BACKROUND PLAN PROVIDED BY: ,10B NUMBER: 55554 SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved J ❑ {�'jjt ❑ s i\idtE.f: 'Er Per Thz, These pians have been r .vi awe i IL Tukwila Fire t-07 CCi' ; ,i" 'Ct_ ".,;i't Current City ;;,..;, ;� Li. _: r.: f and - .:rlc?arils. �;I;,�t,� :. .__. .. _ C, :.I „ F;tions of adopted „ :Iv51CnS V�tiii=:.i tt ,... •`�'.'� - near i s ana for the • ds., .i "i,,,, designer. . �C �;;.C?/ of.:!k t t �� ��.. .. � i.. t,:. L�:..7,gner. /;ons, deietioh:3 tirzwings after , ate will VCi:Ci ?'/1 require a ,esubmi taI of r''aviseec t rawing5 soosequent approval. ilial acceptance is subj C to Field test and inspection by • he Tukwila Fire Prevention Bureau. te: Io -`1 5II TUKWIIA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit Na. and exact address for shut- down or restoraton approval. ST UCKS #03364 General Notes Mall Corridor SOFFIT © 12'-0' AFF EXTEND SOFFIT 4' INTO STORE. PAINT ALL SIDES OF SOFFIT AND ABOVE WOOD GRILLE CEILING. LEGEND: P E NEW BULKHEAD AND SOFFIT TO ALIGN WITH STAR BUCKS BULKHEAD. PAINT TO MATCH EXISTING. AL HEAD �.mL�-3caG'a 1 k:xa a'�is` ip. ` Lx,7Qa.H lEi"'4 PLUGGED HEAD EXISTING HEAD TO REMAIN 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprin-kler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. co FIRE PROTECTION PLAN TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL Hanger No. 070 HILTI Kwik Bolt 111 HILTI Kwik Bolt 11 Drilled Anchor i Cut Rod Lgth Rounded to j Nearest Inch Rod Coupling —� All Thread Rod �„= Swivel Ring Pipe Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension 1/4= 1'-0" HANGFIR DETAIL NOT TO SCALE VICINITY MAP DET ° NOT TO SCALE .� SYMBOL LEGEND 2 -WAY EARTHQUAKE BRACE REVISIONS Sprinkler Legend NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHOUAKE BRACE 1 5.6 Pendent 14" Chrome 155°F REL F1 RECESSED PEND APPROVAL: CITY OF TUKWILA HYDRAULIC REFERENCE POINT 6 5.6 Pendent Chrome 155°F REL G5 CONCEALOR CONT. NO.: KSXXXX 0 HANGER SYMBOL Total = 7 DRAWN BY: Martin Sokolski BRANCHLINE RESTRAINT SPRK. ON SHEET: SEE LEGEND SPRK. ON JOB: 7 HEADS DATE: 10103/12 Western States Fire Protection Company 14880 NE S5TH ST.LI NIT 101- REDMOND, WA- 98052 Lic.9: WESTESFI36QF WESTERN STATES FIRE PROTECTION COMPANY.OFFlCES LOCATED K&IOUEROUE /AUSTIN /DAL LASS DECATUR / oBNER / MUTH 7 NXUSTON MANUS CITY LAS VEDAS /11RAPOUS/FH0@UR/PORTLAND/RAPIDCITY/ST. PAUL/SALT IAXECITY ISEATTLE Phone: 425881-0100 FNL7c425.881-3030 STARBUCKS #3364 506 SOUTHCENTER-BLVD: TUKWILA, WA 98188 FIRE PROTECTION PLAN PAID OCT - 3 2012 TUKWILA FIRE -z71 7 STARBUCKS #3364 uJ UJ Martin Sokulski 0 U CO z 0 0 J_ 8 SHEET FP -1 OF 1 506 SOUTHCENTER MALL ASSOCIATED PERMITS 12-F-228 12-S-219 IFZNAM SITE LOCATION l2-F.Zza CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 1lKing Co. Assessor's Tax No.:���, g�) ,-/Site Address: 1Q SCA.)&\C JV\ �' lCli Suite Number: Floor: V1' al....JW"'t- Tenant Name: Property Owner's Name: q..)4/`QI.6 �w Mailing Address: \ , O 1 \\,A \To L' \\i ` 1'U' ' CONTACT PERSON -if there are questions about the submittal. Name: KARINA VELIZ New Tenant? Yes ❑ - No Company Name: GUARDIAN SECURITY SYSTEMS, INC Mailing Address: 1743 — 1ST AVE S E-mail Address: kveliz@guardiansecurity.com CA (O2 City " State Zip Day Telephone: 206-734-6276 x229 City SEATTLE, WA 98134 State Zip Fax Number: 206-341-9928 Valuation of Project (contractor's bid price): $ / Scope of Work (please provide detailed information): .liw V � �,iu �I lft(.5 A A/ t C . PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING y WNER OR AUTHRIZED AGENT: Signature: Print Name: f(i, Je-1 Date: ,()/(61 /1,2/ Day TelephonerOL,C 2)C ( ) ?C7 Plan Permit App.doc 5/14/10 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 02470010 Site Address: 506 Southcenter Mall Blvd Suite Number: Floor: 1 Tenant Name: Starbucks New Tenant? ❑ - Yes X - No Property Owner's Name: Westfield, LLC Mailing Address: 2800 Southcenter Seattle, WA 98188 CONTACT PERSON -if there are questions about the submittal. Name: Martin Sokulski Day Telephone: (425) 881-0100 Company Name: Western States Fire Protection Mailing Address: 14690 NE 95th Street, Unit 101 E-mail Address: martin.sokulski@wsfp.us Redmond WA 98052 City Fax Number: (425) 881-3030 State Zip Valuation of Project (contractor's bid price): $ 3500 Scope of Work (please provide detailed information): space. Relocate and plug sprinkler heads to meet requirements of new tenant PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NER OR : U HORIZED AGENT: Signature: Print Name: Martin Sokulski Day Telephone: (425) 881-0100 Date: FO/2 /I 2 Plan Permit App doc 5/14/10 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Starbucks 506 Southcenter Mall Permit No.: 12-S-219 Date: October 4, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). r • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON g Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which Co not authorize violations of adopted standards and ordinances. The responsTbility for the adequacy of design rests tote: with the designer. Add -tions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /0 By: 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented % to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. _/-2F-' and exact address for shut- down or restoration approval. SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FIRE ALARM SYSTEM PLAN SHEET INDEX WIRE SCHEDULE AND CONDUIT FILL CHART SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DETECTOR P 1 (PHOTO -ADDRESSABLE) DB1 1BASE SIEMENS 4S DEEP W/ 1G RING CEILING ®D DUCT DETECTOR TSM DUCT DETECTOR TEST SWITCH AD2-P W/ SIEMENS DUCT HOUSING HFP-11 GET. TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD Ell FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS ( C<�:4 kOvi SEARS macys STARBUCKS 506 WIRE DESIGNATION GENERAL NOTES SITE PLAN JCPenney PAID CCT -92012 TUKWILA FIRE cc ,zaD v 1:44 cc (75 o' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: WIRE DESIGNATIIN SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.0. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.0. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DETECTOR P 1 (PHOTO -ADDRESSABLE) DB1 1BASE SIEMENS 4S DEEP W/ 1G RING CEILING ®D DUCT DETECTOR TSM DUCT DETECTOR TEST SWITCH AD2-P W/ SIEMENS DUCT HOUSING HFP-11 GET. TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD Ell FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS ( C<�:4 kOvi SEARS macys STARBUCKS 506 WIRE DESIGNATION GENERAL NOTES SITE PLAN JCPenney PAID CCT -92012 TUKWILA FIRE cc ,zaD v 1:44 cc (75 o' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 DESCRIPTION SHOP DRAWINGS DATE 10/05/12 2 ««< Z 0 0 Z W >•1 (1) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/05/12 BACKROUND PLAN PROVIDED BY: Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved \0B NUMBER: 55554 SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60 Q DEDICATED EMERGENCY l NOTE: FOR ADd110NAL SPEC61CAB0NS SEE PRCOUCT DOCUIENTADOIL *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC ISOLAIVEGRDUNDIAN2 TO NEXT ADDRESSABLE �+ DEVICE STOP IF LAST DEVICE - FROM XLS C@ITROL PANEL (+ OR PREVIWS ADDRESSABLE DEVICE O 0 It 0 0 HTRI—R 0 O o NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0000 0 PAD -3 00 NPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 (-) (+) SPARE SPARE SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PNRWITH SHIELD #18 FPLIFPLR RED (JACKET) *CONTACT RAI1NGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O O '1 4 o 0 HTRI—R _ / O GROUND `LN\`,,___- (+)>TO NEXT DEVICE OR O 0 (-) (-) > STOP IF LAST DEVICE DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/EL.EC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) + u HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END DF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATIN TEMPERATU E: +32' F (0' C) TO 100"F (338' C) HUMIDITY: )-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —\ -4-FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE / STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 i 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL z Li, z 02cc z 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE CV \ 0 0 0 Zco co O CD 10 Z r<i) cc 0 wzz CO >0g, cc < -- Cs) CC LO LL }— �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/05/12 BACKROUND PLAN PROVIDED BY: 'OB NUMBER: 55554 1 C SHEET FA -02 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved \ J = F Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps XIStING:$1810Na. xten er`Patie • CU CiattentLOadir.'1-. ndby: : i• Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 al -MC -CW ©15CD 9 0.0875 ZH-MC-CW ©30CD 7 0.131 al -MC -CW @75CD 5 0.222 •ZH-MC-CW @95CD 2 0.292 0.584 Z1 -1 -HMC -CW ©135CD 0.371 ZR -MC -CW ©15CD 11 0.069 0.759 ZR -MC -W ©15CD 0.064 0.03 Amps 1.373 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.373 Amps For 5 Minutes= 0.115 Amp -hours 25% Derating= 1.044 Amp -hours Total System Current Load: 1.044 Amp -hours 12VDC 7.1AH Notification Appliance Circuit Detail PROJECT: Panel: Date: STARBUCKS EXISTING PAD -3 BPS October 8, 2012 i Wire Resistance 2.58 CURRENT TOTAL= 575.00 .,.,...,.. .„.. Zi -MC -CW @iscd 87i 0: - - 213 -MC -CW .@30ed - - 131- ' 131 . .. _...,.....•.,. ..• 2 7}1 -MC -CW @75cd 222; 444 ,•••,,,-.f..,•.-, ."'.^• •'.•"•,••.T ,....i,,r,),••••....,{" . } .4.- ,,,,.....,. +.< ,.. ....,,* '' •',/ 23 -1 -MC -CIN @96ed - . - 292 ' 0 .._ . _. .• •.,..,..........• jai-MC-cw 0135cd 371 0! 7R -MC -CW @16cd. - 69 DEVICES 3 TOTAL_ mA= 575! 1 I Total Wire Resistance ( R ) Total Device iii;lic cOati, Amps (1) 1 Noltage Drop ( E ) Voiiiige 14 285 : 23.15; 575 :( WL* 2 )*(R/ft) 1.47 (Total Cct Load). :0.58 (E= I * R) 0.85. 24E) 23.15 co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS SYSTEM CALCULATIONS TO NEAREST EXISTING s s EFAw-EOL POWER SUPPLY Si S1-2 S1-2 S1-3 30cd 75cd 75cd TO NEAREST EXISTING DATA LOOP D D,I I HT -RI 21-4 I TSM I FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS DATE 10/05/12 2 <<<<< CC 0 LU z w co .1 z co -185 Z CO 5z E:2 cco 0 2 VII 1E6 w zz ca fr, t51 4=t cc F- o co w crLoD LL H z z 0 —J 0 w >- (i) CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/05/12 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM \JOB NUMBER: 55554 I. SHEET Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FA -03 23'-23/4" TO NEAREST D EXISTING DATA c LOOP TO NEAREST EXISTING POWER SUPPLY o: EXIT S1-1 3Ocd D6 4'-111/2" 3'-11/2"I Workroom 0411 HT-R1 \ \/ �\ 0002 s6 Sales Backbar EOL S1 S1-3 75cd Ll S1-2 �1 75cd j :i 2'-6" 12'- 0" FIRE ALARM SYSTEM PLAN Mall Corridor<> FIELD VERIFY DIMENSION OF BUILD OUT FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: (..) m 0 DESCRIPTION SHOP DRAWINGS DATE N to 0 0 z aaaaa Zco co O_i� � �rn cc w0 zwz W = CO CC > 0v) ctt I— CC c!)Qo- UJ CC LO H 4-CALE: 1 /4"=1 '0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 10/05/12 BACKROUND PLAN PROVIDED BY: ,10B NUMBER: 55554 SHEET FA -04 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved J ❑ {�'jjt ❑ s i\idtE.f: 'Er Per Thz, These pians have been r .vi awe i IL Tukwila Fire t-07 CCi' ; ,i" 'Ct_ ".,;i't Current City ;;,..;, ;� Li. _: r.: f and - .:rlc?arils. �;I;,�t,� :. .__. .. _ C, :.I „ F;tions of adopted „ :Iv51CnS V�tiii=:.i tt ,... •`�'.'� - near i s ana for the • ds., .i "i,,,, designer. . �C �;;.C?/ of.:!k t t �� ��.. .. � i.. t,:. L�:..7,gner. /;ons, deietioh:3 tirzwings after , ate will VCi:Ci ?'/1 require a ,esubmi taI of r''aviseec t rawing5 soosequent approval. ilial acceptance is subj C to Field test and inspection by • he Tukwila Fire Prevention Bureau. te: Io -`1 5II TUKWIIA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit Na. and exact address for shut- down or restoraton approval. ST UCKS #03364 General Notes Mall Corridor SOFFIT © 12'-0' AFF EXTEND SOFFIT 4' INTO STORE. PAINT ALL SIDES OF SOFFIT AND ABOVE WOOD GRILLE CEILING. LEGEND: P E NEW BULKHEAD AND SOFFIT TO ALIGN WITH STAR BUCKS BULKHEAD. PAINT TO MATCH EXISTING. AL HEAD �.mL�-3caG'a 1 k:xa a'�is` ip. ` Lx,7Qa.H lEi"'4 PLUGGED HEAD EXISTING HEAD TO REMAIN 1. Western States Fire Protection to add new pendent heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprin-kler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. co FIRE PROTECTION PLAN TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL Hanger No. 070 HILTI Kwik Bolt 111 HILTI Kwik Bolt 11 Drilled Anchor i Cut Rod Lgth Rounded to j Nearest Inch Rod Coupling —� All Thread Rod �„= Swivel Ring Pipe Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension 1/4= 1'-0" HANGFIR DETAIL NOT TO SCALE VICINITY MAP DET ° NOT TO SCALE .� SYMBOL LEGEND 2 -WAY EARTHQUAKE BRACE REVISIONS Sprinkler Legend NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHOUAKE BRACE 1 5.6 Pendent 14" Chrome 155°F REL F1 RECESSED PEND APPROVAL: CITY OF TUKWILA HYDRAULIC REFERENCE POINT 6 5.6 Pendent Chrome 155°F REL G5 CONCEALOR CONT. NO.: KSXXXX 0 HANGER SYMBOL Total = 7 DRAWN BY: Martin Sokolski BRANCHLINE RESTRAINT SPRK. ON SHEET: SEE LEGEND SPRK. ON JOB: 7 HEADS DATE: 10103/12 Western States Fire Protection Company 14880 NE S5TH ST.LI NIT 101- REDMOND, WA- 98052 Lic.9: WESTESFI36QF WESTERN STATES FIRE PROTECTION COMPANY.OFFlCES LOCATED K&IOUEROUE /AUSTIN /DAL LASS DECATUR / oBNER / MUTH 7 NXUSTON MANUS CITY LAS VEDAS /11RAPOUS/FH0@UR/PORTLAND/RAPIDCITY/ST. PAUL/SALT IAXECITY ISEATTLE Phone: 425881-0100 FNL7c425.881-3030 STARBUCKS #3364 506 SOUTHCENTER-BLVD: TUKWILA, WA 98188 FIRE PROTECTION PLAN PAID OCT - 3 2012 TUKWILA FIRE -z71 7 STARBUCKS #3364 uJ UJ Martin Sokulski 0 U CO z 0 0 J_ 8 SHEET FP -1 OF 1