HomeMy WebLinkAboutPP - 535 SOUTHCENTER MALL - ABERCROMBIE KIDS - PERMITS AND PLANS535 SOUTHCENTER MALL ASSOCIATED PERMITS 13-F-219 13-S-213 13-S-204 13-S-182 1'50- IMIUF CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION 9202470010 King Co. Assessor's Tax No.: Site Address: 535 Southcenter Mall, Tukwila, WA 98188 Suite Number: Floor: Tenant Name: J • Crew New Tenant? - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. ' ` Mailing Address: POB 130940, Carlsbad, CA92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing address:1743 First Ave. South, Seattle, WA 98134 E-mail Address: kveliz@guardiansecurity.com City State Zip Fax Number: 206.628.4990 Valuation of Project (contractor's bid price): $ 3000. Scope of Work (please provide detailed information): Adding 24 devices to existing FACP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 1 WNER OR AUTHORIZED AGENT: Signature: 1° /i sk _� Date: Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 5/14/10 TFD FP Form 8 Ottlair44 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 5 5 Sm."\-ive �/�/� I I lod \ Suite Number: Floor: Tenant Name: J l !(_elki New Tenant? ❑ - Yes ❑ - No Property Owner's Name: W�' \*e- . OJji1j— (',;cu Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: 1C�Q� ?W1 nson Day Telephone: y25.1/8J•7669 Company Name: CyouAY1 rP. W*1 CS'n Mailing Address: �O T.©x \2A \�j nil \ erj' t.., \.)1/4i] P q E-mail Address: JC,SS\Ca.ecrourr r11 CO Th City Fax Number: z/�j' 7,164 Total number of new/relocated devices or sprinkler heads: A Valuation of Project (contractor's bid price): $ 1p ;P133. �^ �" �" Scope of Work (please provide detailed information): , 4r U l ,`t ter YtectdS PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: �% C / Signature: ,a.-RaoDate: 6-23.13 Print Name: tJ� ssI(6t f l th/nscr) Plan Permit App.doc Day Telephone: 142S'`40 )'a 1/2/13 TFD FP Form 8 $ FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: J Crew '535 Southcenter Mall Permit No.: Date: Reviewer: 13-S-213 Septemberl7, 2013 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/ inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. 09/17/2013 09:49 4254818695 CROWN FIRE U�CIGIF14ii1IJ at /(edef' ng 9 September 2013 pI�G John Abei Crown Fire Protection P.O. Box 12113 Mill Creek, WA 98082-0113 RE: J Crew (Westfield Mall, Space No. 676, Ground Level), Tukwila, WA Independent Third Party Review — Fire Sprinkler System Dear Mr. Abel: PAGE 02102 Tuazon Engineering, PLLC 4322 NE 7°' Street Renton, WA 88059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. The following was reviewed: • Fire Sprinkler Sheet 1 of 1 dated 8/26/2013 The document was reviewed for compliance with 2010 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. Drawing indicates new and relocated pendent sprinkler heads installed on an existing sprinkler system for tenant improvement work. I have found the fire sprinkler design to be acceptable with the following comments: 1. Ensure submittal drawing is stamped by a Washington Certificate of Competency holder as required by WAC 212-80 and City of Tukwila requirements. 2. The tenant space appears to be protected by one of the pipe schedule designed sprinkler systems in the mall. The revisions shown comply with 2010 NFPA 13 Table 22.5.3.4 for pipe sizing of ordinary hazard pipe schedule systems. No exceptions noted. A resubmittal to Tuazon En ineerin is not r u red rovided the bove are resolved o the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or eric(ci�tuazon.com with any questions regarding this review. Respectfully, TUAZON ENGINEERING, PLLC 5u2,P Eric P. Tuazon, PE Fire Protection Engineer a F wKOwerYe12013.:10KM.29oern.Weeik arAWIaursw sms..4.0c4r 09/09/2013 11:53 4254818695 FAX TRANSMITTAL CROWN FIRE PAGE 01/01 Fax No. CROWN FIRE PROTECTION, INC. MED 9.9.13 Fire Prevention Bureau Tukwila Fire Department / Al Demo Pe nt \ umber of P:itges (lnelurlin (o ct,) 1 0 Urgent El For Review 0 Please Comment 0 Please Reply FILE 206.575A439 I Flom Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comments Please provide a demo permit to remove sprinkler hears% that are in the way of the new construction at the J. Crew project located at 535 Southcenter Mall. The building permit # is D13-246. Please let us know if you have any questions. Thanks-- P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. IS-S-)%oM and exact address for shut- down hutdown or restoration approval. FX: 425.481.8695 08/08/2013 13:30 4254818695 FAX TRANSMITTAL CROWN FIRE PAGE 01/02 Fax No. CROWN FIRE PROTECTION, INC. EMB: OEM MIS 8.8.13 Fire Prevention Bureau Tukwila Fire Department / Al Demo Permit `uinher of Pagc, (Including ('iii cr) 1 D Urgent a For Review 0 Please Comment LI Please Reply 206.575.4439 Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comments Please provide a demo permit to remove (5) fire sprinkler heads for the J. Crew project at Westfield Southcenter. Please let me know if you have any questions or need any additional information_ Thanks TUKWILA FIRE DEPARTMENT Reese cal" 206-575-4407 and give this Fire Permit No. and exact address for shut- down or restoration approval. P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8695 J. CREW FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUMBER SHEET TITLE FA -01 SYSTEM I N FO MATT O N FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FRE ALA RM SYSTEM PLA SHEET INDEX WIRE SCHEDULE AND CO \ D U IT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 EX 1 1 2 SYMBOL DESCRIPTION MODEL gaaiit as Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conforrn9rice +.^�,ti current City s't=ndaras. S tr, ,'•r r1 -S and oliiissions which r :, riot 'Vfl.rauctrIs of adopted ...•-;•ndards and o=v:..U;,ce3. i:._ ,e _,rs;o;iNcy for the �:dRr: quacy of deli ...., t��: ,�;, ,. r, r... dez'.3ner. r !dit1OnSr Cielet'OF's rj.'' i EVi.3iO;1'a tO i irawir'c-S after this date G_:cepr. .• ;:: .f. -i e a resubmittai of r :vi°;:e ;,', 11:: L ;;,: :t; : Jl:c:t'.L approval. Final acceptance lc The Tukwiru '4• -I -( f; ispection by MANUFACTURER BACKBOX NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Syscems. Faiiere of test: tr.;ill result in a Re-insp;..aj c:n Fee and termination of the testing TUKWILA FIRE DEPARTMENT Pease call 206-575-4407 and give this Fire Permit No. and exa cit ud:'r es for ••�� shut- down c, :u:.:of':t10:1 a p pi c3Val, MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP ® °C MO-OSRSABLE) DHBFP--111 1 BWA/ SIEMENS ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. 4S DEEP W/ 1G RING DUCT HOUSING CEILING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD 10 FIRE ALARM STROBE 9 ZR -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM Ell FIRE ALARM HORN STROBE ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM El JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/k, N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND ,� NORDSTROM 3 LEVELS 171, 27ssf b-? E>FRES frJ e�T.� TOKYO TOS•O d PNx sD.1;2; TF,ERR R AeERCHOMH E s v r01 BEST BUY &CLE CLARK2S SLYC: Y C.1D S 1 1 IOOO 9,E'K SKOES SRO% S CES 0 T.E COM BASIC. 0 RWONS J. CREW 535, SPACE 676 C. i LES 1 - ulcrc.:,. gg'S s ka--i Rss 0 WIRE DESIGNATION GENERAL NOTES SITE PLAN uvo acwry D,5D MS COUNTY VERARY FJ VE�Tx £YF_LExS EASING JCPenney 3 lEWLS 276,469sf PAID SEP 13 2013 TUKWjLA FIRE (' „7.2/ o-5 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE M N 0) 0 o«a« (o cg) O c.);-6 co O Q 721 JI - W w �z W� OC _.1=J W OC/�0 Cr) Z 0 / ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: B. VEZZANI DATE: 09/12/13 BACKROUND PLAN PROVIDED BY: .OB NUMBER: 5971- /- SHEET Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ DEDICATED EMERGENCY -4 NOTE FOR ADOMONAL SPECIFICATIONS SEE PRODUCT DOCUI/ENTATER. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC WArE FRDN DEVICE STD tEXT ADDRESSABLE (+ TDP IP LAST DEVICE FROM XLS CWTRIa. PANEL (f DR PREVIOUS ADDRESSABLE DEVICE 0 i 4 o HTRI-R O o 0 O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) r N � 0000 11 O PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1- 1 2+2- 2 NC C NO + - + - + - + - + - O (-) (+) 2 SPARE SPARE t, SPARE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. S33 z Sz rrio E-3 r C") o M Nv�o -o �v (-)(-) (+)(+) (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPUFPIR RED(JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VOC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O 0 r r 1 GROUND 0 0 O HTRI-R DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. (-) (+)> TO NEXT DEVICE OR /2} STOP IF LAST DEVICE (-) DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL TO NEXT ADDRESSABLE DEVICE -a. FROM XLS CONTROL PANEL OR,J+ PREVIOUS ADDRESSABLE DEVICE `` HOOD EOL 0 .0 GROUND 0 0 CU co 6 0 HTRI—S STATUS LEE 0 CO 0 0 0 NOT USED 0 0 HOOD MONITOR MODULE WIRING DETAIL (-) (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC PIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY u u HORN/STROBE OR STROBE ONLY U u HORN/STROBE ❑R STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32'F (0' C) TO 100'F (3g C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING ) TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL *44.# O JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT e re i 0 0 0 0 TO NEXT DEVICE CADDY BAR 1 SMOKE/HEAT DETECTOR \\- SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL co 4:4 RELEASE/REVISIONS REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS DATE 09/12/13 2 CCCCC 03Z 11.1 co O Ur I-0) QCO Z JO _! W w COZ CC Cf) CC CCW = 7 W 15 +�y� 11 On LI` CO F— M LC) J\ �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: B. VEZZANI DATE: 09/12/13 BACKROUND PLAN PROVIDED BY: .110B NUMBER: 5971—� SHEET FA -02 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved • ' . ..,JCREW , f FACP DESCRIPTION SHOP DRAWINGS Ctitten 6 ,,,; '''' , , ., ' ' f - , . ,Standby: Current Load: , Standby: Alarm: (.1 Device Type Qty Amps Device Type Qty Amps Total Amps Total HTRI-S 0.0096 0 0.0021 0.000 0.03 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.0096 0.0192 0.021 0.042 0.113 0.339 ZH-MC-W ©75CD 2 0.195 0.390 ZH-MC-W ©110CD 2 0.259 0.518 0.0827 Amps 0.106 Amps •' , °:'It q''' " ''''J.CREW ' fT NEW SIEMENS PAD -3 Signal Extender Panel Battery L�ad Calculations DESCRIPTION SHOP DRAWINGS Ctitten 6 ,,,; '''' , , ., ' ' f - , . ,Standby: 1 , (.1 Device Type Qty Amps Total Amps Total 2 <<<<< Main System Board 1 0.03 0.03 0.030 0.030 71 -1 -MC -W ©15CD 2 0.078 0.156 al -MC -W ©30CD 3 0.113 0.339 ZH-MC-W ©75CD 2 0.195 0.390 ZH-MC-W ©110CD 2 0.259 0.518 ZH-H C W @135CD 0.371 1ZR-MC-W ©15CD 10 0.064 0.640 ZR C- 30CD 0.098 0.03 A ps 2.073 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 2.073 Amps For 5 Minute 0.174 Amp -hours 25% Derating= 1.118 Amp -hours Total System Current Load: 1.118 Amp -hours aattery Pair to„be Used: ;I2VDC' ' -. , ) ' . Notification Appliance Circuit Detail PROJECT: J. CREW Panel: NEW PAD -3 BPS (BACK OF HOUSE) Wire Resistance 2.58 Date: September 13, 2013 CURRENT TOTAL= 1703.00 !71 -1 -NIC -W @15cd ' 78! 7,114/16-W o3Occi - 113 . , ZH-MC-W @75cd Zil-MC-W 6110od 259 0 9 :ZR -MC -W @15cd : 64 576 ZR -lie -W 610Cd 98 0 . , . DEVICES :9 : TOTAL mA=.! 236 14 0 196_0 1 2 Total Wire Resistance ( R ) Total Device Load, Amps Voltage broil( E) EOL Volta e- ;. r'rt 23.77! 236! ( ViL * 2) * (R/ft) , 0.96i (Totaled Load) - 1 0.2:eil -(6=1* R) 0.23! : 24 - - ' ' , 23.77 al -MC -W @16cd ! 78 0 - ------ v , ..,,,.. .. .....•-., ... .., V . ZH-MC-W ©30cd 113 226 ,211 -MC -W @75cd , 196' 195 , zi-wMCivi @Bocci 259 - 518 ---- ' :ZR-hic-W @16Cci 64 0 714404v @80cd - 98 . 0 5 TOTAL mA= 939. 14 DEVICES Total Wire Resistance ( R ) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage , 7777, " $R1 615cd 7141C-W-00Od 1 @75cd @71100 1 ZR -MC -W @16cd g30cd DEVICES '5 • "i (WL* 2 )*(Rtfty (Total,tct Load) 0.94 (E= I * R) 1.04 1.10 78 156: 113 113 195 195: 259 0 64! 64: 98 0 TOTAL mA= 528: 14 • 192 23.79! 5-29 Total Wire Resistance ( R ) Total Device Load, Amps (1) Voltage Drop ( E) EOL Voltage ( WL * 2)* (Ftift) 0.99 (T�tal Cct Load) (E= I * 11) 0.52, 21.08 SYSTEM CALCULATIONS TO NEAREST EXISTING SIGNALING CIRCUIT 2C 120VAC, DEDICATED (BY OTHERS) BPS S S S 3S D N. TO NEAREST EXISTING DATA LOOP S3-1 75cd S3-2 S3-3 15cd 15cd S3-4 S3-5 30cd 15cd EOL S3 S s s v v EOL 11 L_i 11 0 LI S2 S2-1 30cd S2-2 S2-3 110cd 30cd S2-4 S2-5 75cd 110cd EO1L S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 S1-8 S1-9 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd D HT -R1 D,1 I FIT -R I 21—c) I TSM 1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY FIELD MOUNTED. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 1 10VAC BRANCH CIRCUIT. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH. LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX IN BACKHOUSE CORRIDOR. 14i C3 02 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 (/) z0 w LU Ch LU (C) LU LU 1REV. BY: I 0 m o DESCRIPTION SHOP DRAWINGS DATE ,r) (.1 ,r, 0 2 <<<<< co z w co o o (1. 0c/)z < 7-1 „ 2 <0 Lll w CC cc F- < . 2 z cr ° LL1 cC OD 0 w z Thwe w z 0 z •==C 0) z 0 0 w CO J ‘ALE: NOT TO SCALE" DRAWN BY: D. GARCIA DESIGNED BY: B. VEZZANI DATE: 09/12/13 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM \JOB NUMBER: 5971-1j FA -03 ( Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET 06 RESTROOM B-2 VT -1 TO NEAREST EXISTING DATA LOOP ti 3S 08 RECEIVING 8-2 ( VT -1 11 ELECTRICAL B_flVT-1 09 KITCHENE I IE 8-2 I VT-` I _. —.�. —. 07 OFFICE 8-2 VT -1 10 BOH B-2 VT -1 (Th FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY FIELD MOUNTED. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH. LOCATIONS TO BE 20ELD VERIFIED -Y ECHANICAL, ELECTRICAL AND FIRE ALAR CONTRACTORS. ,FIELD LOCATE TENANT JUNCTION BOX IN pKHOUSE CORRIDOR. 02A DISPLAY WINDOW B-1 WF -1 i 75c , FITTING C-1 03- MEN'S 8-1 WF -1 S3-5 15cd EOL S3 S2-4 75cd 04 CASHWRAP 0-1 I -1 03A WOMEN'S 0-1 WF -1 11Ocd 03G MEN'S 3-1 WF -1 M 03E WEN'S B-1 ; WI--` D 11 -1T -R1 ITSMJ L 01A ENTRE B-1 WF -1 023 DISPL i WINDOW EOL S2 WF -1 S2-�!. 11Ocd 03H MEN'S B-1 WF -1 0 ,';a,r,. 3-1 WF -1 03B WOMEN'S (R) FLOOR PLAN - FIRE ALARM 12 CLOSET 3-2 VT -1 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved RELEASE/REVISIONS REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS DATE M N 0) 0 2 CCCCC co ZWcOoo OUT � 0) a CO Z W w �Z CC (I)w� CJ � � CCW W cc on L- Wi— tt) t) CO SCALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: B. VEZZANI DATE: 09/12/13 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 5971-1 SHEET ' FA -04 .$p H 13 REAR EXIT VESTIBULE 8'-0" I GWB I MALL MAINTAIN RATED CEILING, FINISH TO MATCH MALL STANDARD. L� J 05 FITTING 06 RESTROOM 10 BOH WALL MOUNTED LIGHT FIXTURE ABOVE DOOR GWB @ FITTING ROOMS 9'-0" TYP. PROVIDE SMOKE DETECTORS QUANTITY AND LOCAIONS AS REQ'D BY CODE PROVIDE SPRINKLERS AS REQ'D BY LOCAL CODE IN BREAK AREA, TYP. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C=CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JDIST/TRUSS HANGER DETAIL NTS 02A DISPLAY.WINDOW SURFACE MTD. TRACK 'T' W/ "N" HEADS, TYP FOR DISPLAY WINDOWS. 1/2" F.T. PLYWOOD WITH GWB ON TOP & BETWEEN OF PLYWOOD @ SHOW WINDOWS CLG. GWB SUFFIT ACCESS DOOR O1B ENTRY VESTIBULE 11.-0" RED LETTER ON WHITE BLADE INSERT EXIT SIGN 02B DISPLAY WINDOW 11'-0" GWB 1: P-9 F CEILING CONTROL JOINT, TYP. 1T%L 03 MEN'S 03 WOMEN'S SURFACE MTD. TRACK "T-2" W/ "N" HEADS, TYP FOR SALES. 03 WOMEN'S 03 WOMEN'S 10'-6" GWB P-9 F P-9 F Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart e 68 — Add Reliable Model G5-56 165° Standard Response Concealed Pendents 1/2 x 1/2 (white) • E — Existing no change 1 REFLECTED CEILING PLAN SCALE: 1 /4" = 1'-O" . SUSPENDED GWB CEILING TYPICAL THRUOUT SALES & FITTING AREAS, U.O.N., SEE SHEETA-7.1 FOR DETAILS. GWB @ ±9'-8" THIS AREA, V.I.F. SITE PLAN NOT TO SCALE JCREW SPACE NO. 676 (LEVEL: GROUND LEVEL) LEASE AREA: 5.073 SQ.FT. 12'-0" 14 CLOSET ACT -1 ❑ Without Comments ❑ As Noted in Red • Per The Attached Lc fter plans have been reviewed by The Tukwila' Fire _ _ntion Bureau for conformance wit's current City standards. Acceptance Is subject to err( rs and . omISS 0415 which do not authorize violat; )ns of adopted standards and ordinances. The respons bllity for.the. adequacy of design rests totally with tilt designer. Additions, deletions or revisions to thes. drawings after. this date will void this acceptance and v it, require a resubmittal of revised drawings for sulx que.nt approval. :Final acceptance Is subl'ect to field test and inspection by The Tukwlia Fire Prevention BureA u. Date: qr/ 7-13 By: CROWN: FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7889 J Crew 5?5 Southcenter Mall, Tukwila, WA PAID. AUG 27 201' E DATE: Le.1:3 DRAWN: SCALE: 0FI 535 SOUTHCENTER MALL ASSOCIATED PERMITS 13-F-219 13-S-213 13-S-204 13-S-182 1'50- IMIUF CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION 9202470010 King Co. Assessor's Tax No.: Site Address: 535 Southcenter Mall, Tukwila, WA 98188 Suite Number: Floor: Tenant Name: J • Crew New Tenant? - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. ' ` Mailing Address: POB 130940, Carlsbad, CA92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing address:1743 First Ave. South, Seattle, WA 98134 E-mail Address: kveliz@guardiansecurity.com City State Zip Fax Number: 206.628.4990 Valuation of Project (contractor's bid price): $ 3000. Scope of Work (please provide detailed information): Adding 24 devices to existing FACP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 1 WNER OR AUTHORIZED AGENT: Signature: 1° /i sk _� Date: Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 5/14/10 TFD FP Form 8 Ottlair44 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 5 5 Sm."\-ive �/�/� I I lod \ Suite Number: Floor: Tenant Name: J l !(_elki New Tenant? ❑ - Yes ❑ - No Property Owner's Name: W�' \*e- . OJji1j— (',;cu Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: 1C�Q� ?W1 nson Day Telephone: y25.1/8J•7669 Company Name: CyouAY1 rP. W*1 CS'n Mailing Address: �O T.©x \2A \�j nil \ erj' t.., \.)1/4i] P q E-mail Address: JC,SS\Ca.ecrourr r11 CO Th City Fax Number: z/�j' 7,164 Total number of new/relocated devices or sprinkler heads: A Valuation of Project (contractor's bid price): $ 1p ;P133. �^ �" �" Scope of Work (please provide detailed information): , 4r U l ,`t ter YtectdS PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: �% C / Signature: ,a.-RaoDate: 6-23.13 Print Name: tJ� ssI(6t f l th/nscr) Plan Permit App.doc Day Telephone: 142S'`40 )'a 1/2/13 TFD FP Form 8 $ FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: J Crew '535 Southcenter Mall Permit No.: Date: Reviewer: 13-S-213 Septemberl7, 2013 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/ inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. 09/17/2013 09:49 4254818695 CROWN FIRE U�CIGIF14ii1IJ at /(edef' ng 9 September 2013 pI�G John Abei Crown Fire Protection P.O. Box 12113 Mill Creek, WA 98082-0113 RE: J Crew (Westfield Mall, Space No. 676, Ground Level), Tukwila, WA Independent Third Party Review — Fire Sprinkler System Dear Mr. Abel: PAGE 02102 Tuazon Engineering, PLLC 4322 NE 7°' Street Renton, WA 88059 425.917.1683 tel 425.917.1705 fax www.tuazon.com As requested, I have performed an Independent Third Party Plan Review on the fire sprinkler system for the above referenced project. The following was reviewed: • Fire Sprinkler Sheet 1 of 1 dated 8/26/2013 The document was reviewed for compliance with 2010 NFPA 13, Installation of Sprinkler Systems and Tukwila Municipal Code Chapter 16.42, Sprinkler Systems. Drawing indicates new and relocated pendent sprinkler heads installed on an existing sprinkler system for tenant improvement work. I have found the fire sprinkler design to be acceptable with the following comments: 1. Ensure submittal drawing is stamped by a Washington Certificate of Competency holder as required by WAC 212-80 and City of Tukwila requirements. 2. The tenant space appears to be protected by one of the pipe schedule designed sprinkler systems in the mall. The revisions shown comply with 2010 NFPA 13 Table 22.5.3.4 for pipe sizing of ordinary hazard pipe schedule systems. No exceptions noted. A resubmittal to Tuazon En ineerin is not r u red rovided the bove are resolved o the satisfaction of Tukwila Fire Department. The comments made above do not relieve the contractor from compliance with requirements of contract drawings, specifications, or codes. Tuazon Engineering has performed a detailed review of the submittal for general conformance with the standards referenced. Please contact me at 425-917-1683 or eric(ci�tuazon.com with any questions regarding this review. Respectfully, TUAZON ENGINEERING, PLLC 5u2,P Eric P. Tuazon, PE Fire Protection Engineer a F wKOwerYe12013.:10KM.29oern.Weeik arAWIaursw sms..4.0c4r 09/09/2013 11:53 4254818695 FAX TRANSMITTAL CROWN FIRE PAGE 01/01 Fax No. CROWN FIRE PROTECTION, INC. MED 9.9.13 Fire Prevention Bureau Tukwila Fire Department / Al Demo Pe nt \ umber of P:itges (lnelurlin (o ct,) 1 0 Urgent El For Review 0 Please Comment 0 Please Reply FILE 206.575A439 I Flom Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comments Please provide a demo permit to remove sprinkler hears% that are in the way of the new construction at the J. Crew project located at 535 Southcenter Mall. The building permit # is D13-246. Please let us know if you have any questions. Thanks-- P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. IS-S-)%oM and exact address for shut- down hutdown or restoration approval. FX: 425.481.8695 08/08/2013 13:30 4254818695 FAX TRANSMITTAL CROWN FIRE PAGE 01/02 Fax No. CROWN FIRE PROTECTION, INC. EMB: OEM MIS 8.8.13 Fire Prevention Bureau Tukwila Fire Department / Al Demo Permit `uinher of Pagc, (Including ('iii cr) 1 D Urgent a For Review 0 Please Comment LI Please Reply 206.575.4439 Cristie Ogland PH:425.481.7669 FX:425.481.8695 Comments Please provide a demo permit to remove (5) fire sprinkler heads for the J. Crew project at Westfield Southcenter. Please let me know if you have any questions or need any additional information_ Thanks TUKWILA FIRE DEPARTMENT Reese cal" 206-575-4407 and give this Fire Permit No. and exact address for shut- down or restoration approval. P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8695 J. CREW FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET NUMBER SHEET TITLE FA -01 SYSTEM I N FO MATT O N FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FRE ALA RM SYSTEM PLA SHEET INDEX WIRE SCHEDULE AND CO \ D U IT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 EX 1 1 2 SYMBOL DESCRIPTION MODEL gaaiit as Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conforrn9rice +.^�,ti current City s't=ndaras. S tr, ,'•r r1 -S and oliiissions which r :, riot 'Vfl.rauctrIs of adopted ...•-;•ndards and o=v:..U;,ce3. i:._ ,e _,rs;o;iNcy for the �:dRr: quacy of deli ...., t��: ,�;, ,. r, r... dez'.3ner. r !dit1OnSr Cielet'OF's rj.'' i EVi.3iO;1'a tO i irawir'c-S after this date G_:cepr. .• ;:: .f. -i e a resubmittai of r :vi°;:e ;,', 11:: L ;;,: :t; : Jl:c:t'.L approval. Final acceptance lc The Tukwiru '4• -I -( f; ispection by MANUFACTURER BACKBOX NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Syscems. Faiiere of test: tr.;ill result in a Re-insp;..aj c:n Fee and termination of the testing TUKWILA FIRE DEPARTMENT Pease call 206-575-4407 and give this Fire Permit No. and exa cit ud:'r es for ••�� shut- down c, :u:.:of':t10:1 a p pi c3Val, MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP ® °C MO-OSRSABLE) DHBFP--111 1 BWA/ SIEMENS ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. 4S DEEP W/ 1G RING DUCT HOUSING CEILING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD 10 FIRE ALARM STROBE 9 ZR -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM Ell FIRE ALARM HORN STROBE ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM El JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/k, N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND ,� NORDSTROM 3 LEVELS 171, 27ssf b-? E>FRES frJ e�T.� TOKYO TOS•O d PNx sD.1;2; TF,ERR R AeERCHOMH E s v r01 BEST BUY &CLE CLARK2S SLYC: Y C.1D S 1 1 IOOO 9,E'K SKOES SRO% S CES 0 T.E COM BASIC. 0 RWONS J. CREW 535, SPACE 676 C. i LES 1 - ulcrc.:,. gg'S s ka--i Rss 0 WIRE DESIGNATION GENERAL NOTES SITE PLAN uvo acwry D,5D MS COUNTY VERARY FJ VE�Tx £YF_LExS EASING JCPenney 3 lEWLS 276,469sf PAID SEP 13 2013 TUKWjLA FIRE (' „7.2/ o-5 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE M N 0) 0 o«a« (o cg) O c.);-6 co O Q 721 JI - W w �z W� OC _.1=J W OC/�0 Cr) Z 0 / ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: B. VEZZANI DATE: 09/12/13 BACKROUND PLAN PROVIDED BY: .OB NUMBER: 5971- /- SHEET Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ DEDICATED EMERGENCY -4 NOTE FOR ADOMONAL SPECIFICATIONS SEE PRODUCT DOCUI/ENTATER. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC WArE FRDN DEVICE STD tEXT ADDRESSABLE (+ TDP IP LAST DEVICE FROM XLS CWTRIa. PANEL (f DR PREVIOUS ADDRESSABLE DEVICE 0 i 4 o HTRI-R O o 0 O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) r N � 0000 11 O PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1- 1 2+2- 2 NC C NO + - + - + - + - + - O (-) (+) 2 SPARE SPARE t, SPARE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. S33 z Sz rrio E-3 r C") o M Nv�o -o �v (-)(-) (+)(+) (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPUFPIR RED(JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VOC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O 0 r r 1 GROUND 0 0 O HTRI-R DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. (-) (+)> TO NEXT DEVICE OR /2} STOP IF LAST DEVICE (-) DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL TO NEXT ADDRESSABLE DEVICE -a. FROM XLS CONTROL PANEL OR,J+ PREVIOUS ADDRESSABLE DEVICE `` HOOD EOL 0 .0 GROUND 0 0 CU co 6 0 HTRI—S STATUS LEE 0 CO 0 0 0 NOT USED 0 0 HOOD MONITOR MODULE WIRING DETAIL (-) (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC PIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY u u HORN/STROBE OR STROBE ONLY U u HORN/STROBE ❑R STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32'F (0' C) TO 100'F (3g C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING ) TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL *44.# O JUNCTION BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT e re i 0 0 0 0 TO NEXT DEVICE CADDY BAR 1 SMOKE/HEAT DETECTOR \\- SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL co 4:4 RELEASE/REVISIONS REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS DATE 09/12/13 2 CCCCC 03Z 11.1 co O Ur I-0) QCO Z JO _! W w COZ CC Cf) CC CCW = 7 W 15 +�y� 11 On LI` CO F— M LC) J\ �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: B. VEZZANI DATE: 09/12/13 BACKROUND PLAN PROVIDED BY: .110B NUMBER: 5971—� SHEET FA -02 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved • ' . ..,JCREW , f FACP DESCRIPTION SHOP DRAWINGS Ctitten 6 ,,,; '''' , , ., ' ' f - , . ,Standby: Current Load: , Standby: Alarm: (.1 Device Type Qty Amps Device Type Qty Amps Total Amps Total HTRI-S 0.0096 0 0.0021 0.000 0.03 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.0096 0.0192 0.021 0.042 0.113 0.339 ZH-MC-W ©75CD 2 0.195 0.390 ZH-MC-W ©110CD 2 0.259 0.518 0.0827 Amps 0.106 Amps •' , °:'It q''' " ''''J.CREW ' fT NEW SIEMENS PAD -3 Signal Extender Panel Battery L�ad Calculations DESCRIPTION SHOP DRAWINGS Ctitten 6 ,,,; '''' , , ., ' ' f - , . ,Standby: 1 , (.1 Device Type Qty Amps Total Amps Total 2 <<<<< Main System Board 1 0.03 0.03 0.030 0.030 71 -1 -MC -W ©15CD 2 0.078 0.156 al -MC -W ©30CD 3 0.113 0.339 ZH-MC-W ©75CD 2 0.195 0.390 ZH-MC-W ©110CD 2 0.259 0.518 ZH-H C W @135CD 0.371 1ZR-MC-W ©15CD 10 0.064 0.640 ZR C- 30CD 0.098 0.03 A ps 2.073 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 2.073 Amps For 5 Minute 0.174 Amp -hours 25% Derating= 1.118 Amp -hours Total System Current Load: 1.118 Amp -hours aattery Pair to„be Used: ;I2VDC' ' -. , ) ' . Notification Appliance Circuit Detail PROJECT: J. CREW Panel: NEW PAD -3 BPS (BACK OF HOUSE) Wire Resistance 2.58 Date: September 13, 2013 CURRENT TOTAL= 1703.00 !71 -1 -NIC -W @15cd ' 78! 7,114/16-W o3Occi - 113 . , ZH-MC-W @75cd Zil-MC-W 6110od 259 0 9 :ZR -MC -W @15cd : 64 576 ZR -lie -W 610Cd 98 0 . , . DEVICES :9 : TOTAL mA=.! 236 14 0 196_0 1 2 Total Wire Resistance ( R ) Total Device Load, Amps Voltage broil( E) EOL Volta e- ;. r'rt 23.77! 236! ( ViL * 2) * (R/ft) , 0.96i (Totaled Load) - 1 0.2:eil -(6=1* R) 0.23! : 24 - - ' ' , 23.77 al -MC -W @16cd ! 78 0 - ------ v , ..,,,.. .. .....•-., ... .., V . ZH-MC-W ©30cd 113 226 ,211 -MC -W @75cd , 196' 195 , zi-wMCivi @Bocci 259 - 518 ---- ' :ZR-hic-W @16Cci 64 0 714404v @80cd - 98 . 0 5 TOTAL mA= 939. 14 DEVICES Total Wire Resistance ( R ) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage , 7777, " $R1 615cd 7141C-W-00Od 1 @75cd @71100 1 ZR -MC -W @16cd g30cd DEVICES '5 • "i (WL* 2 )*(Rtfty (Total,tct Load) 0.94 (E= I * R) 1.04 1.10 78 156: 113 113 195 195: 259 0 64! 64: 98 0 TOTAL mA= 528: 14 • 192 23.79! 5-29 Total Wire Resistance ( R ) Total Device Load, Amps (1) Voltage Drop ( E) EOL Voltage ( WL * 2)* (Ftift) 0.99 (T�tal Cct Load) (E= I * 11) 0.52, 21.08 SYSTEM CALCULATIONS TO NEAREST EXISTING SIGNALING CIRCUIT 2C 120VAC, DEDICATED (BY OTHERS) BPS S S S 3S D N. TO NEAREST EXISTING DATA LOOP S3-1 75cd S3-2 S3-3 15cd 15cd S3-4 S3-5 30cd 15cd EOL S3 S s s v v EOL 11 L_i 11 0 LI S2 S2-1 30cd S2-2 S2-3 110cd 30cd S2-4 S2-5 75cd 110cd EO1L S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 S1-8 S1-9 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd D HT -R1 D,1 I FIT -R I 21—c) I TSM 1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY FIELD MOUNTED. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 1 10VAC BRANCH CIRCUIT. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH. LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX IN BACKHOUSE CORRIDOR. 14i C3 02 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 (/) z0 w LU Ch LU (C) LU LU 1REV. BY: I 0 m o DESCRIPTION SHOP DRAWINGS DATE ,r) (.1 ,r, 0 2 <<<<< co z w co o o (1. 0c/)z < 7-1 „ 2 <0 Lll w CC cc F- < . 2 z cr ° LL1 cC OD 0 w z Thwe w z 0 z •==C 0) z 0 0 w CO J ‘ALE: NOT TO SCALE" DRAWN BY: D. GARCIA DESIGNED BY: B. VEZZANI DATE: 09/12/13 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM \JOB NUMBER: 5971-1j FA -03 ( Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET 06 RESTROOM B-2 VT -1 TO NEAREST EXISTING DATA LOOP ti 3S 08 RECEIVING 8-2 ( VT -1 11 ELECTRICAL B_flVT-1 09 KITCHENE I IE 8-2 I VT-` I _. —.�. —. 07 OFFICE 8-2 VT -1 10 BOH B-2 VT -1 (Th FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. NEW SIEMENS PAD -3 BOOSTER POWER SUPPLY FIELD MOUNTED. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11 OVAC BRANCH CIRCUIT. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH. LOCATIONS TO BE 20ELD VERIFIED -Y ECHANICAL, ELECTRICAL AND FIRE ALAR CONTRACTORS. ,FIELD LOCATE TENANT JUNCTION BOX IN pKHOUSE CORRIDOR. 02A DISPLAY WINDOW B-1 WF -1 i 75c , FITTING C-1 03- MEN'S 8-1 WF -1 S3-5 15cd EOL S3 S2-4 75cd 04 CASHWRAP 0-1 I -1 03A WOMEN'S 0-1 WF -1 11Ocd 03G MEN'S 3-1 WF -1 M 03E WEN'S B-1 ; WI--` D 11 -1T -R1 ITSMJ L 01A ENTRE B-1 WF -1 023 DISPL i WINDOW EOL S2 WF -1 S2-�!. 11Ocd 03H MEN'S B-1 WF -1 0 ,';a,r,. 3-1 WF -1 03B WOMEN'S (R) FLOOR PLAN - FIRE ALARM 12 CLOSET 3-2 VT -1 Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved RELEASE/REVISIONS REV. BY: 0 0 DESCRIPTION SHOP DRAWINGS DATE M N 0) 0 2 CCCCC co ZWcOoo OUT � 0) a CO Z W w �Z CC (I)w� CJ � � CCW W cc on L- Wi— tt) t) CO SCALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: B. VEZZANI DATE: 09/12/13 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 5971-1 SHEET ' FA -04 .$p H 13 REAR EXIT VESTIBULE 8'-0" I GWB I MALL MAINTAIN RATED CEILING, FINISH TO MATCH MALL STANDARD. L� J 05 FITTING 06 RESTROOM 10 BOH WALL MOUNTED LIGHT FIXTURE ABOVE DOOR GWB @ FITTING ROOMS 9'-0" TYP. PROVIDE SMOKE DETECTORS QUANTITY AND LOCAIONS AS REQ'D BY CODE PROVIDE SPRINKLERS AS REQ'D BY LOCAL CODE IN BREAK AREA, TYP. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C=CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JDIST/TRUSS HANGER DETAIL NTS 02A DISPLAY.WINDOW SURFACE MTD. TRACK 'T' W/ "N" HEADS, TYP FOR DISPLAY WINDOWS. 1/2" F.T. PLYWOOD WITH GWB ON TOP & BETWEEN OF PLYWOOD @ SHOW WINDOWS CLG. GWB SUFFIT ACCESS DOOR O1B ENTRY VESTIBULE 11.-0" RED LETTER ON WHITE BLADE INSERT EXIT SIGN 02B DISPLAY WINDOW 11'-0" GWB 1: P-9 F CEILING CONTROL JOINT, TYP. 1T%L 03 MEN'S 03 WOMEN'S SURFACE MTD. TRACK "T-2" W/ "N" HEADS, TYP FOR SALES. 03 WOMEN'S 03 WOMEN'S 10'-6" GWB P-9 F P-9 F Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart e 68 — Add Reliable Model G5-56 165° Standard Response Concealed Pendents 1/2 x 1/2 (white) • E — Existing no change 1 REFLECTED CEILING PLAN SCALE: 1 /4" = 1'-O" . SUSPENDED GWB CEILING TYPICAL THRUOUT SALES & FITTING AREAS, U.O.N., SEE SHEETA-7.1 FOR DETAILS. GWB @ ±9'-8" THIS AREA, V.I.F. SITE PLAN NOT TO SCALE JCREW SPACE NO. 676 (LEVEL: GROUND LEVEL) LEASE AREA: 5.073 SQ.FT. 12'-0" 14 CLOSET ACT -1 ❑ Without Comments ❑ As Noted in Red • Per The Attached Lc fter plans have been reviewed by The Tukwila' Fire _ _ntion Bureau for conformance wit's current City standards. Acceptance Is subject to err( rs and . omISS 0415 which do not authorize violat; )ns of adopted standards and ordinances. The respons bllity for.the. adequacy of design rests totally with tilt designer. Additions, deletions or revisions to thes. drawings after. this date will void this acceptance and v it, require a resubmittal of revised drawings for sulx que.nt approval. :Final acceptance Is subl'ect to field test and inspection by The Tukwlia Fire Prevention BureA u. Date: qr/ 7-13 By: CROWN: FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7889 J Crew 5?5 Southcenter Mall, Tukwila, WA PAID. AUG 27 201' E DATE: Le.1:3 DRAWN: SCALE: 0FI