Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 566 SOUTHCENTER MALL - UNKNOWN TENANT - PERMITS AND PLANS
566 SOUTHCENTER MALL ASSOCIATED PERMITS 11-F-242 11-S-245 09-F-174 09-S-164 SITE LOCATION Site Address: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 566 So e - Moak Tenant Name: 3-41-4^N ' (off 5 -L4 -(U2_ King Co. Assessor's Tax No.: Suite Number: Floor: New Tenant? NI - Yes ❑ - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: O �' �� ` t c `e. Day Telephone: C20G7 3Scl (2 8 Company Name: G""`Q^^ Se C 41 Mailing Address: 174S 4S \ 4 c S (JJ Jest �.l ( et% k 3 r (' le City S to Zip E-mail Address: � r �la�� a''�lCt-urt • `-iD�"N Fax Number: 02067 ��{ \��'l2$ Valuation of Project (contractor's bid price): $ y i C D Scope of Work(pl easeprovide detailed information): A deliTi os s 1 ' 't 11 X04, vi.,�'-� S -,1S° } 1 ' i 5 S-fQ C.sZ • PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU QBIZ ' D AGENT: Signature: �/ Date: ( 0126/11 /� Print Name: R aed.1 rls 7 f,{ 'e - Day Telephone: e .) 3 1 7'v4? Plan Permit App.doc 5/14/10 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Spec Space 566 Southcenter Mall Permit No.: 09-S-164 Date: October 23, 2009 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/ inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more heads require hydrostatic test and system isolation if necessary. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2007 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Jamba Juice 566 Southcenter Mall Permit No.: 11-S-245 Date: October 28, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test; and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. SERVICE SERVICE UNE OF WALK --1r4 UNIT BELOW WALK-IN UNIT COMPRESSOR ABOVE ON ROOF GYP. BD. 11' 6' AFF r# IF REQUIRED BY CODE, NON-FREEZING SPRINKLER HEADS WITH WIRE PROTECTION CAGES SHALL BE USED IN WALK-IN BOX. COORDINATE LOCATIONS WITH WALK-IN VENDOR SCALE: 1/4" = 11-0' 0 2 4 ❑ Without Comments ❑ As Noted in Red Per The Attached Letter ?se plans have been reviewed by The Tukwila Fire evention Bureau for conformance with current City ndards. Acceptance is subject to errors and fissions which do not authorize violations of adopted 3ndards and ordinances. The responsibility for the quacy of design rests totally with the designer. nitions, deletk ns or revisions to these drawings after k date will void this acceptance and will require a esubmlttal Of revised drawings for subsequent approval. ,nal acceptance is subject to field test and inspection .by l he Tukwila Fire Prevention Bureau. Date: /n -16 "I( By: `TUCWILA FIRE DEPARTMENT Please call 206-575-44Q7 and give this Fire Permit No. 11-S-2.`ts' and exact address for shut- down hutdown or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testina. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD RED PIPE SWIVEL RING STEEL. JDIST/TRUSS HANGER DETAIL NTS Design per NFPA 13, Ordinary Hazard All materials to be new, U.L. listed, and F.M. approved All.u;e-sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart • 7 — Add Reliable Model F156 Standard Response 155° Pendents I/2 x I/2 2 — Add Viking Model VK 154 Standard Response 200° Dry Pendents 1/2 x 1/2 9 Total CROWN FIRE PROTECTION INCORPORATE D P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 JAMBA JUICE WESTFIELD SOUTHCENTER 566 SOUTHCENTER MALL SPACE# 1110 1-ULw,161, l� DATE: 7 a 21 I I{ DRAWN: / cr. PAID OCT 24 2011 TUKWILA FIRE SCALE: h t } 5 t ¢ 3 il FIRE ALARM SYSTEM ADDITIONTUKWILA, WASHINGTON SHEET NUIv3ER SHEET TITLE FA -01 SYSTEIv IN FOR MATIO\ FA -02 TYPICAL WIRI\G A\D MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SI \ G LE LINE DIAGRAM FA -04 FRE ALARM SYSTEIV PLA\ SHEET INDEX Aw CETE D D• Without Comments 0 As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City t ndards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, dele ;ons or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bure, u. tDate:10 )-"1- I ( By: WI J C TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. 11- and exact address for shut- down hutdown or restoration approval. IDULE AND NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptanci Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. CO\DUIT FILL CHA RT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 EPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKED V SPEAKER CIRCUIT- FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT- RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE TEST SWITCH TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34' SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE WSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 1 2 2 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS acres macys LEVEL __.O: O %sf yJfGL LSTs . xs EtduAl T,E PAPE ti Prc PETAL aY FtYIE+'S PYUCS CLAIRE'S �4aai ❑ EWPI 0 P'1.BPU i R S.£P & cr. ,,S: a- i I J.f n's C%NE4. .ti 0Jn ..Ar Los _GES !N 3 mervyivs 2 LE'.EL 65.23%s` Mk" PA RE, a IESAWVR PA,* PAM" �' NVI-(�(, roil/ 3 LEVELS WIRE DESIGNATION GENERAL NOTES SITE PLAN 3 LEVELS 27,43( •k PAID OCT 2 6 2011 TUKWILA FIRE frz,„ -z ozzo- TI 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE N 0 111 >• 'SCALE: NOT TO SCALE\ DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:10/25/ 1 1 BACKROUND PLAN PROVIDED BY: �OB NUMBER: 55351 c Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 } THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET—\ SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6011Z DEDICATED EMERGENCY l N31E FOR ►XI1D L SPECMCM (S SEE PRODUCT DOOAENTAflO I. *CONTACT RADE& 4.0A 0 123VAC 4.0A 0 30VVC TO TEXT ADDRESSABLE DEVICE STOP 7 LAST DEVICE FRD 4 XLS coma. PANEL (r DR PREVIOUS ADDRESSABLE DEVICE O 0 /.' GROUND 7 G 0 HTRI—R 0 'El O ° O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 00 00 II PAD -3 00 INPUT MUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1— 1 2+2— 2 NC C NO + — + — + — + — + — 0 01 (-) (+) SPARE SPARE 2 SPARE c FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) WIRE DESIGNATION: NUMBEROFCONDUCTORS SIZE TYPE COLOR CODE TMISTEDPAIRWITHSHIELD #18 FPUFPLR RED(JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.a 0 30VOC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O F GROUND L 7— (-) i 0 0 0 0 -) I @. I HTRI—R 13 DRY CONTACTS TO VAV - FAN SHUTDOWN PROVIDED BY MECH/ELEC. (+)> TO NEXT DEVICE OR STOP IF LAST DEVICE (-) DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FLED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL U U HORN/STROBE OR STROBE ONLY U U HORN/STROBE OR STROBE ONLY 0 + HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER 11N TEMPERATU E +32' F 0' C) TO 1001 F (338' C) HUMIDITY: 0-9 y RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS USTED FOR MR VOLOCITY APPLICATIONS OF 300-4000 FT IN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 • STANDARD SMOKE DETECTOR BASE FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL �DO�pp� p♦0� 0 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /- HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 00 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR '— SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL 1743 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: C, 3 0 DESCRIPTION SHOP DRAWINGS DATE 10/25/11 (0 co Z 00 0NT CO 1-1-1 CTS t�o)o —' <Jr~z R V w � < FJ) EIC.A m2 z� 2 CIC w <g=g W CCD Cf) LL O In �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:10/25/ 1 1 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 55351 SHEET Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FA -02 J FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project: Westfield Mall -Jamba Juice space #566 Panel: PAD -3 w/Siemens Notification Appliances Date: October 25, 2011 Module/Device Qty Standby (mA) Total Standby (mA) Alarm (mA) Total Alarm (mA) Power Module 1 75 80 0 140 140 0 A TOTAL FIRE ALARM POWER SUPPLY B Auxiliary Device Current C Notification Appliance Load (Max. Total) D E F G H J K Tota I(A)= CALCULATION 80 0 0 80 Total(B)= 140 0 4787 4927 Total current ratings of all devices in system (line A + line B + line C) 80 4927 Total current ratings converted to amperes (line D x .001) 0.08 4.927 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 1.92 Alarm sounding period in hours (5 mins+ .0833 hours) 10/25/11 0.0833 Multiply lines E and H Total Alarm AH 0.4104191 Add lines G and I Total Standby and Alarm AH 2.3304191 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 2.79650292 Amp Hour Battery Provided 7.2 Amp Hour PROJECT: Panel: Date: CIRCUIT: QTY 1 1 1 DEVICES= CIRCUIT: QTY 1 DEVICES= CIRCUIT: QTY 1 DEVICES= CIRCUIT: QTY 1 DEVICES= Notification Appliance Circuit Detail Westfield Mall -Jamba Juice space #566 PAD -3 w/Siemens Notification Appliances October 25, 2011 PS1 Device Type Alarm Current Alarm Total Wire Size ZR -MC -C @ 15cd 69 69 ZN-MC-C @ 15cd 87 87 ZN-MC-C @ 30cd 131 131 3 TOTAL mA= 287 14 PS2 Device Type Full Load 1 PS3 Device Type Full Load 1 PS4 Device Type Full Load 1 Alarm Current 1500 TOTAL m A= Alarm Current 1500 TOTAL m A= Alarm Current 1500 TOTAL m A= CURRENT TOTAL= 4787 Wire Length Voltage at EOL Circuit Total 150 23.725341 287 Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 1500 1500 14 150 22.5645 1500 Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 1500 1500 14 400 20.172 1500 Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 1500 1500 14 550 18.7365 1500 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS SYSTEM CALCULATIONS TO EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-1 15cd S1-1 75cd D,1 51-1 75cd JHT-RI 21 -+ TSM EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, TEST SWITCH MODULE & RELAY MODULE FOR FAN SHUTDOWN LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. REV. BY: (3 a DESCRIPTION SHOP DRAWINGS DATE 10/25/11 CD U) Z o - Oco W0� 0Q J o w �z Ca mcn <g=S CC On LL WI— N. U, CC w z LU 0 z C) a Z C/) z 0 LU Ci) >- Cl) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:10/25/ 1 1 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved ..JOB NUMBER: 55351 SHEET FA -03 TO NEAREST DATA LOOP < TO EXISTING POWER SUPPLY < r FREEZER R A 1.31lrtr l�E f N M.U.SUENAMI F 1, _ .. - I/ EOL -S1 S1-3 - ^Naval 301cd CD --S I i1 li \ S A ^< HT 0 4,1 II{ IT I_ f I 1 FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, TEST SWITCH MODULE & RELAY MODULE FOR FAN SHUTDOWN LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS FREV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS 1 DATE N 0 z ««< CO CD u7 zT« Ocio WQaz C� d J oR V ffip 11-1 (I) 2 ccOD � z � BUJ (/)I- N. 0 U, 4-CALE: 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:10/25/ 1 1 BACKROUND PLAN PROVIDED BY: JJOB NUMBER: 55351 SHEET FA -04 COPY L'OCCITANE POP-UP FIRE ALARM SYSTEM BELLEVUE, WA 98004 SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL), RISER FA -04 FIRE ALARM SYSTEM FLOOR PLAN D Without Comments As Noted in Red ❑ Per The Attached Letter Thse plans have been reviewed by The Tukwila Fire evenrion Bureau for conformance with current City :�nc ards. Acceptance is subject to errors and - emissions which. do not authorize violations of adopted D-Idards and ordinances. The responsibility for the e,, quecy of design rests totally with the designer. , d ai ons, deletions or revisions to these drawings after • ruts Wyte, will void this acceptance and will require:',a resubmittal or revised drawings for subsequent approval. Final acceptance is subject to•field test and inspection by Tne Tukwila Fire Prevention Bureau. Date: / I -)- - 4 `1 By: 74-1"45/ lcisoit.e (.14,-12 a4, AAA 44 FS circ.. A" Sy'lgke✓ TUKWILA FIRE DEPARTIVILINA Please call: 575-4407 enci a this job Na. OI-15:- and I- and exact address for shut. down or rest.3ration aDorovm# NOTICE A completed, signed, Tukwa Fire Department Pre-test Certificate must be, presented.. to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Feeand termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH not lor¢ Apr nenrn nu Arm rnMnl irr rrr i &$J I .r .r TA.vr►J rr,ni. ►1 r r. nLin n "-Art, r SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF -THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY SYMBOL DESCRIPTION 2 MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FATP FIRE ALARM CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP 1 2 EX TRI -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD TRI -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP BOX VERIFY IN FIELD [a DUCT SMOKE DETECTOR AD2-P W/ SIEMENS HFP-11 DET DUCT HOUSING VERIFY IN FIELD r SMOKE DETECTOR (PHOTOELECTRIC) HFP-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. dl• FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM © STROBE (WALL MOUNT) ST -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM PAM MULTI -VOLTAGE RELAY MODULE PAM -1 AIR PRODUCTS 4S BOX VERIFY IN FIELD FIRE SMOKE DAMPER F.B,❑, F.B.O. N/A VERIFY IN FIELD FATC EX JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD Fs WATER FLOW SWITCH F.B.O. F.B.O. N/A VERIFY IN FIELD TS TAMPER SWITCH F.B.O. F.B.O. VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.❑, FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAin oar 2 2009 Tukwila Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION I SHOP DRAWINGS DATE 10/28/09 2 <C<<< J 0 cie 2 izcco oo OWIW-o ZF.- < F/3 cog 0 cc 8 0 LL `O ~ 0 J Z 0 F... 0 W N (SCALE: NOT TO SCALE DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 10/28/09 BACKROUND PLAN PROVIDED BY: t1OB NUMBER: SHEET tA FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE; SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. DUCT DETECTOR-" LOCATION BEND OR OTHER OBSTRUCTION BEND OR OTHER OBSTRUCTION TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE STROBE 24K STROBE CIRCUIT SPEAKER jvme 24K STROBE CIRCUIT STROBE SPEAKER + — 0 0 SPEAKERISTROBE AND STROBE WIRING LABEL SCALE 120VAC HOT NEUTRAL 0 0 SPEAKER CIRCUIT TYPICAL FOR DAMPERS DAMPER — HOT O NEUTRAL 0 120VAC WHT Z Q BLU -O -OBLK PAM -1 SHOP DRAWINGS O O RED DATE 10/28/09 OR NC NO DATA CABLE DATA CABLE ///// GROUND NOT SHIELD @ HTRI—R STATUS LID car r-0 KL; (0 0 HTRI-R WITH PAM -1 INSIDE 4S DEEP BOX WITH EXTENSION RING TYPICAL WIRING FOR DAMPERS & FAN CONTACTOR POWER SCALE:NONE (STATUS & CONFIRMATION) THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE; SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. STROBE CIRCUIT TUBE OUTLET \ SAMPLING TUBE INLET- -\ SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE STROBE 0 STROBE CIRCUIT SPEAKER 0 Cy STROBE CIRCUIT SPEAKER CIRCUIT FAN TYPICAL FAN CONTACTOR POWER CLOSED DAMPER CONTACTS NO C NC O _qvv_p OPEN DAMPER CONTACTS NO C NC O /vv -c) DATA CABLE so 0 0 t) ///// GROUND NOT SHIELD @ 0 HTRI—D STATUS LED NGT WED ao0 K0. m0 HTRI-D INSIDE 4S DEEP BOX SPEAKER CIRCUIT 12X12 JBOX GENERAL NOTES 1. 2. 3. 4. 5. FRONT VIEW I 1, NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DATA OUT (+) C Sl DATA OUT () C TO NEXT DEVICE SPEAKERS ARE TAPPED AT 70.7114 WATT. STROBES CANDELAS ARE ON THE FIELD DRAWINGS. CHECK CUT SHEETS SUPPLIED WITH PARTS BEFORE HOOKING -UP. ALL ALD LOOP WIRES MUST BE IN METAL RACEWAY. DD -11 STMUARD SMOKE DETECTOR BASE — NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP REB[ (+) � F ALO 0 0— 470 OHMS SIN EOL p 1C t INPU 100 ONOMm T`M-1 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD Ir18 FPUFPLR RED (JACKET) 000 �Mo CCCIC (-) TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE JUNCTION BOX MOUNTED ON CEILING. FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT J / r / / / / / / / 0 0 0 0 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR -- SMOKE DETECTOR MOUNTING SCALE:NONE ANY ALD LOOP WIRE THAT GOES TO FANS / DAMPERS THAT ARE PART OF PRESSURIZING OR VENTING SMOKE CONTROL, NEED TO BE IN METAL RACEWAY AND 2 -HOUR PROTECTED (CI CABLE OR ENCLOSED IN 2 -HOUR CONCRETE OR SHEETROCK. (+)TO NEXT DEVICE OR 1 -) STOP IF LAST DEVICE)? DAMPER CONTACTS NO C NC O c TO NEXT + ^rte ADDRESSABLE DE DATA CABLE • 0 @ @ ©STATUS LID HTRI—R ar 0 N CO DAMPER HOOT 0 NEUTRAL //i// GROUND NOT SHIELD DAMPER STATUS CONFIRMATION & ACTIVATION SCALE:NONE SUSPENDED ILLUMINATED CEILING TO NEXT ADDRESSABLE DEVICE NEUTRAL 0 120VAC HOT COMBINE ALL SHIELDS MID ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STIP IF LAST DEVICE Jaj FROM XLS CONTROL. PANEL PREVIOUS ADDRESSABLE EARTH GROUND -*.(+)TO NEXT DEVICE OR 1 >(-) STOP IF LAST DEVICE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER,,TING TEMPERATURE: +32' F 0' C) TO 100' F (31T C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 I STANDARD i SMOKE DETECTOR BASE --> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICEE— > ( ) DATA OUT} > (+) DATA OUT )7 CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSION N CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE:NONE 0 GM) N AC _fl 0 0 Oil 00 0 CI 0 PAD -3 0 LL�.1 00 r(5, INPUT INPUT TROUBLE NAC NAC2 NAC3 NAC4 AUX 1+1— 1 2+2— 2 NC C NO + — + — + — + — + — HTRI-R ®STATUS LID o 0 KO 3.6k WI n_ h 0 NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL WIRING FOR HTRI-R MODULE (PAD -3 TRIP) SCALE NONE STUD SHEET ROCK SPEAKER STROBE OR _ STROBE ONLY 2 NAC -4 2 NAC -3 NAC -2 NAC -1 Copyright 4S DEEP BOX W/ 1-1/2' EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) 0` 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 1REV. BY: Z Q DESCRIPTION SHOP DRAWINGS DATE 10/28/09 2 CaCC( CL W z� Wa Z cc< 5)). W U cc ED 0 LL u7 F- O z z O CD z 0 z E 0) J J am: �CALE: NOT TO SCALE DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 10/28/09 BACKROUND PLAN PROVIDED BY: WALL `COUNTED SPEAKER STROBE FIRE MOUNTING ELEVATIONS°B NUMBER: SCALE:NONE I. SHEET 2006 by Guardian Security Systems, Inc. All Rights Reserved FA -02 SYSTEM CALCULATIONS t-- - ----- - PROJECT: L'occitane Pop-up Panel:IXLS-V Date: j October 28, 2009 Notification Appliance Circuit Detail jWire Resistance 2.58 CURRENT TOTAL= 162 1 SET -MC ©15CD .„. SET -MC @30CD DEVICES= 2 641 - 98 TOTAL mA= Total Wire Resistance ( R ) Total Device Load, Amps (I) Voltage Drop ( E ) IEOL Voltage 641, 98 162 14 335 20.12 WL * 2 )* (P(ft) (Total Cct Load) (E= 1* R) 20.4 - E) 162 1.73 0.16 0.28 20.12 Panel: XLS-V Wire Resistance 2.58 0 70.7V 1/8 2 70.7V 1/4 0 70.7V112 0 70.7V1' DEVICES= 2 1.8 o 361 7211 0 - 0 0 I TOTAL m A= " 72 1 (WL*2)*(Rlft)._ r • 0.99 1(Total Cct Load)! 0.07 o.oi 20.331 Total Wire Resistance ( R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage (E= I * R) (20.4 - E) L'OCCITANE POP-UP SIEMENS FACPADDONS DESCRIPTION SHOP DRAWINGS Current Load: Current Load:.. , , , , Standby: Alarm: , Alarm: Device Type Qty Amps Total Amps Total Amps HFP-11 0 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 0.030 HTR -R. 2 0.009600 0.0096 0.021 0.042 0.064 HTRI-D 0 0.001600 0 0.0035 0.000 0.098 0.098 SE'r- C©75CD 0.175 ZR-MCgl5CD 0.0753 Amps 0.106 Amps ZR -MC VOCD 0.098 Standby Current Load: 0.0753 Amps For 24 Hours = 1.807 Amp -hours Amps 0.192 Amps Alarm Current Load: 0.106 Amps For 15 Minutes 0.027 Amp -hours For 24 Hours = 0.720 Amp -hours 25% Derating= 2.292 Amp -hours Amps For 5 Minutes 0.016 Amp -hours Total System Current Load: 2.292 Amp -hours 25% Derating = 0.920 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 8AH LTAGE DROP CALCULATION BATTERY SIZING CALCULATION EX 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 Cl) LU uJ V) LU -J LU REV. BY: , -, j ,t POP-UP SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS Current Load:.. , , , , ,, .t,t;,,,/,; ,, Standby: , Alarm: Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 sErac ©15CD 1 0.064 0.064 SET -MC @30CD 1 0.098 0.098 SE'r- C©75CD 0.175 ZR-MCgl5CD 0.064 ZR -MC VOCD 0.098 0.03 Amps 0.192 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.192 Amps For 5 Minutes 0.016 Amp -hours 25% Derating = 0.920 Amp -hours Total System Currerit Load: 0.920 Amp -hours Battery Pair to be Used:,, tipi No urs, 7HR, , ' LTAGE DROP CALCULATION BATTERY SIZING CALCULATION EX 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 Cl) LU uJ V) LU -J LU REV. BY: z < DESCRIPTION SHOP DRAWINGS DATE 10/28/09 g.‘i cc co u- O w z w < III 2 (-)..r Z cc < < w o cc a3m 0 L0E- 0 w irk w z w (i) z (i) ) (I)} ‘CALE: NOT TO SCALE DRAWN BY: LANDERSON DESIGNED BY: R.VEZZAN I DATE: 10/28/09 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM .10B NUMBER: /' SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FA -03 } RET41 EOL—S1 20.33V 2S,2V BPS FACP EOL—V1 TRI—R 2I J RC NORTH L'OCCITANE POP-UP SCALE 114°=1' FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE THESE DEVICES, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT, TENANT FIRE ALARM JUNCTION BOX (FIELD LOCATE) EXISTING CORE AND SHELL FIRE SMOKE DAMPERS RELAY TRIPS TO ACIVATE AND MONIT❑RS PAD 3 1743 1ST AVE. SO., SEATTLE, WASHINGT1 FAX (206) 628-1+990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z Q DESCRIPTION SHOP DRAWINGS DATE 10/28/09 Z 0 CC 0 0 wz« CL wQ W ��3 w Z CC F- 0 < (/)I • "E >. Lou_ (/) J CC w CC ‘CALE: 1/4" =1' DRAWN BY: !.ANDERSON DESIGNED BY: R.VEZZANI DATE:10/28/09 BACKROUND PLAN PROVIDED BY: '0B NUMBER: SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved F" '-O4 J/ CEILING AT 11'-0" AFF BOTTOM OF SOFFIT AT 10'-0" AFF MALL COMMON AREA EDGE OF SOFFIT TO ALIGN WITH EDGE OF MULLION CEILING AT 11'-01" APF -� • • .•RECE D. UOWNLIGHT:.. :.: .TYPJCAL'UF (S):. • . • 'RETAIL AREA -f:. 10th.• • 4' FLOURESCENT STRIP LIGHT4 TYPICAL OF 13) AT 10"-0" AFFF /1 ROOM K 3 - 101 3'-0" 3'-0" REFLECTED CEILING PLAN 1/4" = 1'-0" Design per NFPA 13 - Ordinary Hazard Occupancy -130 sq ft per sprinkler All materials to be new, U.L. listed, and F.M. approved All heads to be a minimum of 6' apart and to be unobstructed by any means • - Add Reliable Model G4A 165° Concealed Sprinkler Heads, White Cover Plate V2 x %z 7 - Total RETAINER STRAP WHERE; IN SEISMIC AREAS TPP REAM/ C -CLAMP WITH SET SCREW 3/EI' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS Model MT -3 & MT -9 Mectanlcal tee serves the same function as MT -1 a MT -8 but uses a steel electro plated u -bolt to save space and fur easier installation in tight places. it is ideal• for direct connections with sprinkler heeds•and drop nipples. HOUSING: Ductile Iron ASTM A536 grade 65-45-12. COATING: Zinc electroplated U - HOLT: Carbon steel SAE grade 2, zinc plated. NUT Ca Won steel ASTM A194, zinc plated. GASKET: EPDM (-30°F to + 230°F) THREADS: MT -3 NPT per ANSI/ASME 81.20.1 MT -9 British standard parallel (BSP) par 9521 I A • • C£ ❑ YY til 3�d _�� :gid i .. • 1.r:rs r..•��,.. •s `va 6� Per ik.tt _- ti. = HE;iter These-pl ns have been.rev c= ci !:: fie iu'kwi1a Fire Prevention Bureau for carltormarI e ,:1:rh current City - standards. Acceptance is subject to errors and omissions which do not authorize vIciia=or.s of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer: Additions, deletions or revisions to these drawings after this date will void this acceptance and will reg1re'a resubmittal of revised drawings for subsequent approval. Final acceptance.is subject. to field test and inspection by The Tukwila Fire Prevention Bureau. Dote: /0/),-3/ 09 By: AI'vl� + 1 TUKWILA FIRE DEPARTMEtlt1 Please call: 575.4407, and give this job - NO. 09 •tS-« �f and exact address' for shuts clown or restoration aoorovvl: • C R 0 W FIRE PROTECTION INCORP ORA TED P.Q. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 TENANANT IMPROVEMENT 566 SOUTHCENTER TU KW I LA, WA 98188 11)0 OCT -PAL L ._• ?009 'Tukwila Fire LJ SCALE: I/y % J T 4 >rcifAl iC1tl.* 1 _. .._., ... . NOMIH61. 1R: IN 111A5, YON 8160 P.5.11 HOF, 5111 16. e/utM5 tow1 rt mm - APP ROK. *$ ION T EACH A 11 C 0 0 I 114 412 300 1.19 2.15 1.54 0:50 131 } 2.23 . 0.53 11/48314 OW 1.19 2.14 1.64 350 1.21 2.75 0.87 1 114 4 1 280 133 2.27 1.51 3.30 1.21 2.25. 1.06 1 12, 472 100 ' _ 1.49 236 1.78 3.50 1.73 2.26 9.93 1125314 300 700 1.49 1.42 225 239 1.78 1.73 ' 2.50 3.50 1.33 151 225 235 0.67 4.54 1 1/2 R 1 2.1/2 100 1.10 2.51 2.01 3.73 1,18 2.75 u.141 252/4 200 1.:5 2.51 r 2.01 3.72 1.0S 2,25 0.96 2 1 1 300 1.19 253 1,59 :1.75 1.5'. 1.25 I. r . 2.25 1.09 7.09 2 1/1 5 112 300 - 1.19 2.75 7.29 4.25 4.54 21r4: 3/4 300 1.'9 2.76 2.25 425 1.144 2.29 026 2 1/2 5 1 300 4:9 2.59 2.22 7.52 4,23 t III 2.25 1.14 3°.0..12 260 'U.O.a3143 1.'9 262 4.25 4 00 2.2a I 0.69 3 i i -1-7Mt� 1.'5 262 2.32 4.75 1.74 2.25 4 9.20 1.:9 2.95 229 4.25- .- --_1.59 --- 3.33 • . 1.4.1 I A • • C£ ❑ YY til 3�d _�� :gid i .. • 1.r:rs r..•��,.. •s `va 6� Per ik.tt _- ti. = HE;iter These-pl ns have been.rev c= ci !:: fie iu'kwi1a Fire Prevention Bureau for carltormarI e ,:1:rh current City - standards. Acceptance is subject to errors and omissions which do not authorize vIciia=or.s of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer: Additions, deletions or revisions to these drawings after this date will void this acceptance and will reg1re'a resubmittal of revised drawings for subsequent approval. Final acceptance.is subject. to field test and inspection by The Tukwila Fire Prevention Bureau. Dote: /0/),-3/ 09 By: AI'vl� + 1 TUKWILA FIRE DEPARTMEtlt1 Please call: 575.4407, and give this job - NO. 09 •tS-« �f and exact address' for shuts clown or restoration aoorovvl: • C R 0 W FIRE PROTECTION INCORP ORA TED P.Q. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 TENANANT IMPROVEMENT 566 SOUTHCENTER TU KW I LA, WA 98188 11)0 OCT -PAL L ._• ?009 'Tukwila Fire LJ SCALE: I/y % J 566 SOUTHCENTER MALL ASSOCIATED PERMITS 11-F-242 11-S-245 09-F-174 09-S-164 SITE LOCATION Site Address: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 566 So e - Moak Tenant Name: 3-41-4^N ' (off 5 -L4 -(U2_ King Co. Assessor's Tax No.: Suite Number: Floor: New Tenant? NI - Yes ❑ - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: O �' �� ` t c `e. Day Telephone: C20G7 3Scl (2 8 Company Name: G""`Q^^ Se C 41 Mailing Address: 174S 4S \ 4 c S (JJ Jest �.l ( et% k 3 r (' le City S to Zip E-mail Address: � r �la�� a''�lCt-urt • `-iD�"N Fax Number: 02067 ��{ \��'l2$ Valuation of Project (contractor's bid price): $ y i C D Scope of Work(pl easeprovide detailed information): A deliTi os s 1 ' 't 11 X04, vi.,�'-� S -,1S° } 1 ' i 5 S-fQ C.sZ • PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU QBIZ ' D AGENT: Signature: �/ Date: ( 0126/11 /� Print Name: R aed.1 rls 7 f,{ 'e - Day Telephone: e .) 3 1 7'v4? Plan Permit App.doc 5/14/10 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Spec Space 566 Southcenter Mall Permit No.: 09-S-164 Date: October 23, 2009 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/ inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more heads require hydrostatic test and system isolation if necessary. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2007 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Jamba Juice 566 Southcenter Mall Permit No.: 11-S-245 Date: October 28, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test; and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. SERVICE SERVICE UNE OF WALK --1r4 UNIT BELOW WALK-IN UNIT COMPRESSOR ABOVE ON ROOF GYP. BD. 11' 6' AFF r# IF REQUIRED BY CODE, NON-FREEZING SPRINKLER HEADS WITH WIRE PROTECTION CAGES SHALL BE USED IN WALK-IN BOX. COORDINATE LOCATIONS WITH WALK-IN VENDOR SCALE: 1/4" = 11-0' 0 2 4 ❑ Without Comments ❑ As Noted in Red Per The Attached Letter ?se plans have been reviewed by The Tukwila Fire evention Bureau for conformance with current City ndards. Acceptance is subject to errors and fissions which do not authorize violations of adopted 3ndards and ordinances. The responsibility for the quacy of design rests totally with the designer. nitions, deletk ns or revisions to these drawings after k date will void this acceptance and will require a esubmlttal Of revised drawings for subsequent approval. ,nal acceptance is subject to field test and inspection .by l he Tukwila Fire Prevention Bureau. Date: /n -16 "I( By: `TUCWILA FIRE DEPARTMENT Please call 206-575-44Q7 and give this Fire Permit No. 11-S-2.`ts' and exact address for shut- down hutdown or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testina. RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/9' ALL THREAD RED PIPE SWIVEL RING STEEL. JDIST/TRUSS HANGER DETAIL NTS Design per NFPA 13, Ordinary Hazard All materials to be new, U.L. listed, and F.M. approved All.u;e-sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart • 7 — Add Reliable Model F156 Standard Response 155° Pendents I/2 x I/2 2 — Add Viking Model VK 154 Standard Response 200° Dry Pendents 1/2 x 1/2 9 Total CROWN FIRE PROTECTION INCORPORATE D P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 JAMBA JUICE WESTFIELD SOUTHCENTER 566 SOUTHCENTER MALL SPACE# 1110 1-ULw,161, l� DATE: 7 a 21 I I{ DRAWN: / cr. PAID OCT 24 2011 TUKWILA FIRE SCALE: h t } 5 t ¢ 3 il FIRE ALARM SYSTEM ADDITIONTUKWILA, WASHINGTON SHEET NUIv3ER SHEET TITLE FA -01 SYSTEIv IN FOR MATIO\ FA -02 TYPICAL WIRI\G A\D MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SI \ G LE LINE DIAGRAM FA -04 FRE ALARM SYSTEIV PLA\ SHEET INDEX Aw CETE D D• Without Comments 0 As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City t ndards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, dele ;ons or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bure, u. tDate:10 )-"1- I ( By: WI J C TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. 11- and exact address for shut- down hutdown or restoration approval. IDULE AND NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptanci Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. CO\DUIT FILL CHA RT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 EPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKED V SPEAKER CIRCUIT- FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT- RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE TEST SWITCH TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34' SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE WSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 1 2 2 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS acres macys LEVEL __.O: O %sf yJfGL LSTs . xs EtduAl T,E PAPE ti Prc PETAL aY FtYIE+'S PYUCS CLAIRE'S �4aai ❑ EWPI 0 P'1.BPU i R S.£P & cr. ,,S: a- i I J.f n's C%NE4. .ti 0Jn ..Ar Los _GES !N 3 mervyivs 2 LE'.EL 65.23%s` Mk" PA RE, a IESAWVR PA,* PAM" �' NVI-(�(, roil/ 3 LEVELS WIRE DESIGNATION GENERAL NOTES SITE PLAN 3 LEVELS 27,43( •k PAID OCT 2 6 2011 TUKWILA FIRE frz,„ -z ozzo- TI 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE N 0 111 >• 'SCALE: NOT TO SCALE\ DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:10/25/ 1 1 BACKROUND PLAN PROVIDED BY: �OB NUMBER: 55351 c Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 } THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET—\ SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6011Z DEDICATED EMERGENCY l N31E FOR ►XI1D L SPECMCM (S SEE PRODUCT DOOAENTAflO I. *CONTACT RADE& 4.0A 0 123VAC 4.0A 0 30VVC TO TEXT ADDRESSABLE DEVICE STOP 7 LAST DEVICE FRD 4 XLS coma. PANEL (r DR PREVIOUS ADDRESSABLE DEVICE O 0 /.' GROUND 7 G 0 HTRI—R 0 'El O ° O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 00 00 II PAD -3 00 INPUT MUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+1— 1 2+2— 2 NC C NO + — + — + — + — + — 0 01 (-) (+) SPARE SPARE 2 SPARE c FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) WIRE DESIGNATION: NUMBEROFCONDUCTORS SIZE TYPE COLOR CODE TMISTEDPAIRWITHSHIELD #18 FPUFPLR RED(JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.a 0 30VOC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O F GROUND L 7— (-) i 0 0 0 0 -) I @. I HTRI—R 13 DRY CONTACTS TO VAV - FAN SHUTDOWN PROVIDED BY MECH/ELEC. (+)> TO NEXT DEVICE OR STOP IF LAST DEVICE (-) DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FLED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL U U HORN/STROBE OR STROBE ONLY U U HORN/STROBE OR STROBE ONLY 0 + HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER 11N TEMPERATU E +32' F 0' C) TO 1001 F (338' C) HUMIDITY: 0-9 y RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS USTED FOR MR VOLOCITY APPLICATIONS OF 300-4000 FT IN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR r— DB -11 • STANDARD SMOKE DETECTOR BASE FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL �DO�pp� p♦0� 0 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /- HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 00 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR '— SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL 1743 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: C, 3 0 DESCRIPTION SHOP DRAWINGS DATE 10/25/11 (0 co Z 00 0NT CO 1-1-1 CTS t�o)o —' <Jr~z R V w � < FJ) EIC.A m2 z� 2 CIC w <g=g W CCD Cf) LL O In �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:10/25/ 1 1 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 55351 SHEET Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved FA -02 J FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project: Westfield Mall -Jamba Juice space #566 Panel: PAD -3 w/Siemens Notification Appliances Date: October 25, 2011 Module/Device Qty Standby (mA) Total Standby (mA) Alarm (mA) Total Alarm (mA) Power Module 1 75 80 0 140 140 0 A TOTAL FIRE ALARM POWER SUPPLY B Auxiliary Device Current C Notification Appliance Load (Max. Total) D E F G H J K Tota I(A)= CALCULATION 80 0 0 80 Total(B)= 140 0 4787 4927 Total current ratings of all devices in system (line A + line B + line C) 80 4927 Total current ratings converted to amperes (line D x .001) 0.08 4.927 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 1.92 Alarm sounding period in hours (5 mins+ .0833 hours) 10/25/11 0.0833 Multiply lines E and H Total Alarm AH 0.4104191 Add lines G and I Total Standby and Alarm AH 2.3304191 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 2.79650292 Amp Hour Battery Provided 7.2 Amp Hour PROJECT: Panel: Date: CIRCUIT: QTY 1 1 1 DEVICES= CIRCUIT: QTY 1 DEVICES= CIRCUIT: QTY 1 DEVICES= CIRCUIT: QTY 1 DEVICES= Notification Appliance Circuit Detail Westfield Mall -Jamba Juice space #566 PAD -3 w/Siemens Notification Appliances October 25, 2011 PS1 Device Type Alarm Current Alarm Total Wire Size ZR -MC -C @ 15cd 69 69 ZN-MC-C @ 15cd 87 87 ZN-MC-C @ 30cd 131 131 3 TOTAL mA= 287 14 PS2 Device Type Full Load 1 PS3 Device Type Full Load 1 PS4 Device Type Full Load 1 Alarm Current 1500 TOTAL m A= Alarm Current 1500 TOTAL m A= Alarm Current 1500 TOTAL m A= CURRENT TOTAL= 4787 Wire Length Voltage at EOL Circuit Total 150 23.725341 287 Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 1500 1500 14 150 22.5645 1500 Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 1500 1500 14 400 20.172 1500 Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 1500 1500 14 550 18.7365 1500 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS SYSTEM CALCULATIONS TO EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-1 15cd S1-1 75cd D,1 51-1 75cd JHT-RI 21 -+ TSM EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, TEST SWITCH MODULE & RELAY MODULE FOR FAN SHUTDOWN LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. REV. BY: (3 a DESCRIPTION SHOP DRAWINGS DATE 10/25/11 CD U) Z o - Oco W0� 0Q J o w �z Ca mcn <g=S CC On LL WI— N. U, CC w z LU 0 z C) a Z C/) z 0 LU Ci) >- Cl) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:10/25/ 1 1 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved ..JOB NUMBER: 55351 SHEET FA -03 TO NEAREST DATA LOOP < TO EXISTING POWER SUPPLY < r FREEZER R A 1.31lrtr l�E f N M.U.SUENAMI F 1, _ .. - I/ EOL -S1 S1-3 - ^Naval 301cd CD --S I i1 li \ S A ^< HT 0 4,1 II{ IT I_ f I 1 FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, TEST SWITCH MODULE & RELAY MODULE FOR FAN SHUTDOWN LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS FREV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS 1 DATE N 0 z ««< CO CD u7 zT« Ocio WQaz C� d J oR V ffip 11-1 (I) 2 ccOD � z � BUJ (/)I- N. 0 U, 4-CALE: 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:10/25/ 1 1 BACKROUND PLAN PROVIDED BY: JJOB NUMBER: 55351 SHEET FA -04 COPY L'OCCITANE POP-UP FIRE ALARM SYSTEM BELLEVUE, WA 98004 SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 SYSTEM CALCULATIONS (GENERAL), RISER FA -04 FIRE ALARM SYSTEM FLOOR PLAN D Without Comments As Noted in Red ❑ Per The Attached Letter Thse plans have been reviewed by The Tukwila Fire evenrion Bureau for conformance with current City :�nc ards. Acceptance is subject to errors and - emissions which. do not authorize violations of adopted D-Idards and ordinances. The responsibility for the e,, quecy of design rests totally with the designer. , d ai ons, deletions or revisions to these drawings after • ruts Wyte, will void this acceptance and will require:',a resubmittal or revised drawings for subsequent approval. Final acceptance is subject to•field test and inspection by Tne Tukwila Fire Prevention Bureau. Date: / I -)- - 4 `1 By: 74-1"45/ lcisoit.e (.14,-12 a4, AAA 44 FS circ.. A" Sy'lgke✓ TUKWILA FIRE DEPARTIVILINA Please call: 575-4407 enci a this job Na. OI-15:- and I- and exact address for shut. down or rest.3ration aDorovm# NOTICE A completed, signed, Tukwa Fire Department Pre-test Certificate must be, presented.. to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Feeand termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH not lor¢ Apr nenrn nu Arm rnMnl irr rrr i &$J I .r .r TA.vr►J rr,ni. ►1 r r. nLin n "-Art, r SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF -THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY SYMBOL DESCRIPTION 2 MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FATP FIRE ALARM CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP 1 2 EX TRI -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD TRI -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP BOX VERIFY IN FIELD [a DUCT SMOKE DETECTOR AD2-P W/ SIEMENS HFP-11 DET DUCT HOUSING VERIFY IN FIELD r SMOKE DETECTOR (PHOTOELECTRIC) HFP-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. dl• FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM © STROBE (WALL MOUNT) ST -MC -W SIEMENS 4S BOX 80" A.F.F. TO BOTTOM PAM MULTI -VOLTAGE RELAY MODULE PAM -1 AIR PRODUCTS 4S BOX VERIFY IN FIELD FIRE SMOKE DAMPER F.B,❑, F.B.O. N/A VERIFY IN FIELD FATC EX JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD Fs WATER FLOW SWITCH F.B.O. F.B.O. N/A VERIFY IN FIELD TS TAMPER SWITCH F.B.O. F.B.O. VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.❑, FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAin oar 2 2009 Tukwila Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION I SHOP DRAWINGS DATE 10/28/09 2 <C<<< J 0 cie 2 izcco oo OWIW-o ZF.- < F/3 cog 0 cc 8 0 LL `O ~ 0 J Z 0 F... 0 W N (SCALE: NOT TO SCALE DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 10/28/09 BACKROUND PLAN PROVIDED BY: t1OB NUMBER: SHEET tA FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE; SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. DUCT DETECTOR-" LOCATION BEND OR OTHER OBSTRUCTION BEND OR OTHER OBSTRUCTION TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE STROBE 24K STROBE CIRCUIT SPEAKER jvme 24K STROBE CIRCUIT STROBE SPEAKER + — 0 0 SPEAKERISTROBE AND STROBE WIRING LABEL SCALE 120VAC HOT NEUTRAL 0 0 SPEAKER CIRCUIT TYPICAL FOR DAMPERS DAMPER — HOT O NEUTRAL 0 120VAC WHT Z Q BLU -O -OBLK PAM -1 SHOP DRAWINGS O O RED DATE 10/28/09 OR NC NO DATA CABLE DATA CABLE ///// GROUND NOT SHIELD @ HTRI—R STATUS LID car r-0 KL; (0 0 HTRI-R WITH PAM -1 INSIDE 4S DEEP BOX WITH EXTENSION RING TYPICAL WIRING FOR DAMPERS & FAN CONTACTOR POWER SCALE:NONE (STATUS & CONFIRMATION) THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE; SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. STROBE CIRCUIT TUBE OUTLET \ SAMPLING TUBE INLET- -\ SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE STROBE 0 STROBE CIRCUIT SPEAKER 0 Cy STROBE CIRCUIT SPEAKER CIRCUIT FAN TYPICAL FAN CONTACTOR POWER CLOSED DAMPER CONTACTS NO C NC O _qvv_p OPEN DAMPER CONTACTS NO C NC O /vv -c) DATA CABLE so 0 0 t) ///// GROUND NOT SHIELD @ 0 HTRI—D STATUS LED NGT WED ao0 K0. m0 HTRI-D INSIDE 4S DEEP BOX SPEAKER CIRCUIT 12X12 JBOX GENERAL NOTES 1. 2. 3. 4. 5. FRONT VIEW I 1, NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DATA OUT (+) C Sl DATA OUT () C TO NEXT DEVICE SPEAKERS ARE TAPPED AT 70.7114 WATT. STROBES CANDELAS ARE ON THE FIELD DRAWINGS. CHECK CUT SHEETS SUPPLIED WITH PARTS BEFORE HOOKING -UP. ALL ALD LOOP WIRES MUST BE IN METAL RACEWAY. DD -11 STMUARD SMOKE DETECTOR BASE — NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP REB[ (+) � F ALO 0 0— 470 OHMS SIN EOL p 1C t INPU 100 ONOMm T`M-1 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD Ir18 FPUFPLR RED (JACKET) 000 �Mo CCCIC (-) TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE JUNCTION BOX MOUNTED ON CEILING. FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT J / r / / / / / / / 0 0 0 0 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR -- SMOKE DETECTOR MOUNTING SCALE:NONE ANY ALD LOOP WIRE THAT GOES TO FANS / DAMPERS THAT ARE PART OF PRESSURIZING OR VENTING SMOKE CONTROL, NEED TO BE IN METAL RACEWAY AND 2 -HOUR PROTECTED (CI CABLE OR ENCLOSED IN 2 -HOUR CONCRETE OR SHEETROCK. (+)TO NEXT DEVICE OR 1 -) STOP IF LAST DEVICE)? DAMPER CONTACTS NO C NC O c TO NEXT + ^rte ADDRESSABLE DE DATA CABLE • 0 @ @ ©STATUS LID HTRI—R ar 0 N CO DAMPER HOOT 0 NEUTRAL //i// GROUND NOT SHIELD DAMPER STATUS CONFIRMATION & ACTIVATION SCALE:NONE SUSPENDED ILLUMINATED CEILING TO NEXT ADDRESSABLE DEVICE NEUTRAL 0 120VAC HOT COMBINE ALL SHIELDS MID ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STIP IF LAST DEVICE Jaj FROM XLS CONTROL. PANEL PREVIOUS ADDRESSABLE EARTH GROUND -*.(+)TO NEXT DEVICE OR 1 >(-) STOP IF LAST DEVICE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER,,TING TEMPERATURE: +32' F 0' C) TO 100' F (31T C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 I STANDARD i SMOKE DETECTOR BASE --> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICEE— > ( ) DATA OUT} > (+) DATA OUT )7 CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSION N CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE:NONE 0 GM) N AC _fl 0 0 Oil 00 0 CI 0 PAD -3 0 LL�.1 00 r(5, INPUT INPUT TROUBLE NAC NAC2 NAC3 NAC4 AUX 1+1— 1 2+2— 2 NC C NO + — + — + — + — + — HTRI-R ®STATUS LID o 0 KO 3.6k WI n_ h 0 NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL WIRING FOR HTRI-R MODULE (PAD -3 TRIP) SCALE NONE STUD SHEET ROCK SPEAKER STROBE OR _ STROBE ONLY 2 NAC -4 2 NAC -3 NAC -2 NAC -1 Copyright 4S DEEP BOX W/ 1-1/2' EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) 0` 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 1REV. BY: Z Q DESCRIPTION SHOP DRAWINGS DATE 10/28/09 2 CaCC( CL W z� Wa Z cc< 5)). W U cc ED 0 LL u7 F- O z z O CD z 0 z E 0) J J am: �CALE: NOT TO SCALE DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 10/28/09 BACKROUND PLAN PROVIDED BY: WALL `COUNTED SPEAKER STROBE FIRE MOUNTING ELEVATIONS°B NUMBER: SCALE:NONE I. SHEET 2006 by Guardian Security Systems, Inc. All Rights Reserved FA -02 SYSTEM CALCULATIONS t-- - ----- - PROJECT: L'occitane Pop-up Panel:IXLS-V Date: j October 28, 2009 Notification Appliance Circuit Detail jWire Resistance 2.58 CURRENT TOTAL= 162 1 SET -MC ©15CD .„. SET -MC @30CD DEVICES= 2 641 - 98 TOTAL mA= Total Wire Resistance ( R ) Total Device Load, Amps (I) Voltage Drop ( E ) IEOL Voltage 641, 98 162 14 335 20.12 WL * 2 )* (P(ft) (Total Cct Load) (E= 1* R) 20.4 - E) 162 1.73 0.16 0.28 20.12 Panel: XLS-V Wire Resistance 2.58 0 70.7V 1/8 2 70.7V 1/4 0 70.7V112 0 70.7V1' DEVICES= 2 1.8 o 361 7211 0 - 0 0 I TOTAL m A= " 72 1 (WL*2)*(Rlft)._ r • 0.99 1(Total Cct Load)! 0.07 o.oi 20.331 Total Wire Resistance ( R ) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage (E= I * R) (20.4 - E) L'OCCITANE POP-UP SIEMENS FACPADDONS DESCRIPTION SHOP DRAWINGS Current Load: Current Load:.. , , , , Standby: Alarm: , Alarm: Device Type Qty Amps Total Amps Total Amps HFP-11 0 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 0.030 HTR -R. 2 0.009600 0.0096 0.021 0.042 0.064 HTRI-D 0 0.001600 0 0.0035 0.000 0.098 0.098 SE'r- C©75CD 0.175 ZR-MCgl5CD 0.0753 Amps 0.106 Amps ZR -MC VOCD 0.098 Standby Current Load: 0.0753 Amps For 24 Hours = 1.807 Amp -hours Amps 0.192 Amps Alarm Current Load: 0.106 Amps For 15 Minutes 0.027 Amp -hours For 24 Hours = 0.720 Amp -hours 25% Derating= 2.292 Amp -hours Amps For 5 Minutes 0.016 Amp -hours Total System Current Load: 2.292 Amp -hours 25% Derating = 0.920 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 8AH LTAGE DROP CALCULATION BATTERY SIZING CALCULATION EX 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 Cl) LU uJ V) LU -J LU REV. BY: , -, j ,t POP-UP SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS Current Load:.. , , , , ,, .t,t;,,,/,; ,, Standby: , Alarm: Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 sErac ©15CD 1 0.064 0.064 SET -MC @30CD 1 0.098 0.098 SE'r- C©75CD 0.175 ZR-MCgl5CD 0.064 ZR -MC VOCD 0.098 0.03 Amps 0.192 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.192 Amps For 5 Minutes 0.016 Amp -hours 25% Derating = 0.920 Amp -hours Total System Currerit Load: 0.920 Amp -hours Battery Pair to be Used:,, tipi No urs, 7HR, , ' LTAGE DROP CALCULATION BATTERY SIZING CALCULATION EX 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 Cl) LU uJ V) LU -J LU REV. BY: z < DESCRIPTION SHOP DRAWINGS DATE 10/28/09 g.‘i cc co u- O w z w < III 2 (-)..r Z cc < < w o cc a3m 0 L0E- 0 w irk w z w (i) z (i) ) (I)} ‘CALE: NOT TO SCALE DRAWN BY: LANDERSON DESIGNED BY: R.VEZZAN I DATE: 10/28/09 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM .10B NUMBER: /' SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FA -03 } RET41 EOL—S1 20.33V 2S,2V BPS FACP EOL—V1 TRI—R 2I J RC NORTH L'OCCITANE POP-UP SCALE 114°=1' FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE THESE DEVICES, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT, TENANT FIRE ALARM JUNCTION BOX (FIELD LOCATE) EXISTING CORE AND SHELL FIRE SMOKE DAMPERS RELAY TRIPS TO ACIVATE AND MONIT❑RS PAD 3 1743 1ST AVE. SO., SEATTLE, WASHINGT1 FAX (206) 628-1+990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z Q DESCRIPTION SHOP DRAWINGS DATE 10/28/09 Z 0 CC 0 0 wz« CL wQ W ��3 w Z CC F- 0 < (/)I • "E >. Lou_ (/) J CC w CC ‘CALE: 1/4" =1' DRAWN BY: !.ANDERSON DESIGNED BY: R.VEZZANI DATE:10/28/09 BACKROUND PLAN PROVIDED BY: '0B NUMBER: SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved F" '-O4 J/ CEILING AT 11'-0" AFF BOTTOM OF SOFFIT AT 10'-0" AFF MALL COMMON AREA EDGE OF SOFFIT TO ALIGN WITH EDGE OF MULLION CEILING AT 11'-01" APF -� • • .•RECE D. UOWNLIGHT:.. :.: .TYPJCAL'UF (S):. • . • 'RETAIL AREA -f:. 10th.• • 4' FLOURESCENT STRIP LIGHT4 TYPICAL OF 13) AT 10"-0" AFFF /1 ROOM K 3 - 101 3'-0" 3'-0" REFLECTED CEILING PLAN 1/4" = 1'-0" Design per NFPA 13 - Ordinary Hazard Occupancy -130 sq ft per sprinkler All materials to be new, U.L. listed, and F.M. approved All heads to be a minimum of 6' apart and to be unobstructed by any means • - Add Reliable Model G4A 165° Concealed Sprinkler Heads, White Cover Plate V2 x %z 7 - Total RETAINER STRAP WHERE; IN SEISMIC AREAS TPP REAM/ C -CLAMP WITH SET SCREW 3/EI' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS Model MT -3 & MT -9 Mectanlcal tee serves the same function as MT -1 a MT -8 but uses a steel electro plated u -bolt to save space and fur easier installation in tight places. it is ideal• for direct connections with sprinkler heeds•and drop nipples. HOUSING: Ductile Iron ASTM A536 grade 65-45-12. COATING: Zinc electroplated U - HOLT: Carbon steel SAE grade 2, zinc plated. NUT Ca Won steel ASTM A194, zinc plated. GASKET: EPDM (-30°F to + 230°F) THREADS: MT -3 NPT per ANSI/ASME 81.20.1 MT -9 British standard parallel (BSP) par 9521 I A • • C£ ❑ YY til 3�d _�� :gid i .. • 1.r:rs r..•��,.. •s `va 6� Per ik.tt _- ti. = HE;iter These-pl ns have been.rev c= ci !:: fie iu'kwi1a Fire Prevention Bureau for carltormarI e ,:1:rh current City - standards. Acceptance is subject to errors and omissions which do not authorize vIciia=or.s of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer: Additions, deletions or revisions to these drawings after this date will void this acceptance and will reg1re'a resubmittal of revised drawings for subsequent approval. Final acceptance.is subject. to field test and inspection by The Tukwila Fire Prevention Bureau. Dote: /0/),-3/ 09 By: AI'vl� + 1 TUKWILA FIRE DEPARTMEtlt1 Please call: 575.4407, and give this job - NO. 09 •tS-« �f and exact address' for shuts clown or restoration aoorovvl: • C R 0 W FIRE PROTECTION INCORP ORA TED P.Q. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 TENANANT IMPROVEMENT 566 SOUTHCENTER TU KW I LA, WA 98188 11)0 OCT -PAL L ._• ?009 'Tukwila Fire LJ SCALE: I/y % J T 4 >rcifAl iC1tl.* 1 _. .._., ... . NOMIH61. 1R: IN 111A5, YON 8160 P.5.11 HOF, 5111 16. e/utM5 tow1 rt mm - APP ROK. *$ ION T EACH A 11 C 0 0 I 114 412 300 1.19 2.15 1.54 0:50 131 } 2.23 . 0.53 11/48314 OW 1.19 2.14 1.64 350 1.21 2.75 0.87 1 114 4 1 280 133 2.27 1.51 3.30 1.21 2.25. 1.06 1 12, 472 100 ' _ 1.49 236 1.78 3.50 1.73 2.26 9.93 1125314 300 700 1.49 1.42 225 239 1.78 1.73 ' 2.50 3.50 1.33 151 225 235 0.67 4.54 1 1/2 R 1 2.1/2 100 1.10 2.51 2.01 3.73 1,18 2.75 u.141 252/4 200 1.:5 2.51 r 2.01 3.72 1.0S 2,25 0.96 2 1 1 300 1.19 253 1,59 :1.75 1.5'. 1.25 I. r . 2.25 1.09 7.09 2 1/1 5 112 300 - 1.19 2.75 7.29 4.25 4.54 21r4: 3/4 300 1.'9 2.76 2.25 425 1.144 2.29 026 2 1/2 5 1 300 4:9 2.59 2.22 7.52 4,23 t III 2.25 1.14 3°.0..12 260 'U.O.a3143 1.'9 262 4.25 4 00 2.2a I 0.69 3 i i -1-7Mt� 1.'5 262 2.32 4.75 1.74 2.25 4 9.20 1.:9 2.95 229 4.25- .- --_1.59 --- 3.33 • . 1.4.1 I A • • C£ ❑ YY til 3�d _�� :gid i .. • 1.r:rs r..•��,.. •s `va 6� Per ik.tt _- ti. = HE;iter These-pl ns have been.rev c= ci !:: fie iu'kwi1a Fire Prevention Bureau for carltormarI e ,:1:rh current City - standards. Acceptance is subject to errors and omissions which do not authorize vIciia=or.s of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer: Additions, deletions or revisions to these drawings after this date will void this acceptance and will reg1re'a resubmittal of revised drawings for subsequent approval. Final acceptance.is subject. to field test and inspection by The Tukwila Fire Prevention Bureau. Dote: /0/),-3/ 09 By: AI'vl� + 1 TUKWILA FIRE DEPARTMEtlt1 Please call: 575.4407, and give this job - NO. 09 •tS-« �f and exact address' for shuts clown or restoration aoorovvl: • C R 0 W FIRE PROTECTION INCORP ORA TED P.Q. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 TENANANT IMPROVEMENT 566 SOUTHCENTER TU KW I LA, WA 98188 11)0 OCT -PAL L ._• ?009 'Tukwila Fire LJ SCALE: I/y % J