Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 328 SOUTHCENTER MALL - UNKNOWN TENANT - PERMITS AND PLANS
328 SOUTHCENTER MALL ASSOCIATED PERMITS 12-F-212 4itt SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. StAd l **PLEASE PRINT** 1 ` oingCo. Assessor's Tax No.: Site Address: (�t,A �.A 11�.1J�t (�v�`� G� &i t umber: Tenant Name: ‘0(-, _ 1,0-1/111r)(-\ Property Owner's Name: V _ QM \ Pel Ck LLC Mailing Address%Q qt (-J ' iVd ' t'ct ' 1 I 1/1_, LA° IN ` (t2-; New Tenant?\tit- Yes ❑ - No CONTACT PERSO N -if there are questions about the submittal. Name:/Y 1.1 Ve t, Company Name: C -'ix" SAX-l.C/"r Mailing Address: 1T W7) 1X V7 t ALJ, - S �` J ,City E-mail Address: �v l., ` (� � U C&J'(c1(c 1 s /V City State Zip Day Telephone: ' I< L "LI Z �- • t G . 5/ ` aq ak lj7umber: I sneirq ao Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Lu v c) 1 0_641 (1g y,c, ,aii( VV\ -- PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING' R OR AUT RAZED AGENT: Signature: nJ Print Name:,Y l 1 ICi Plan Permit App.doc Date:/(2-1-4 / l Day TelephoneaL '02,t/ te646X29 5/14/10 TFD FP Form 8 IRE T SH ffiliml I N" IY DDITION N NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to. commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee a.ntd termination of the testing, jAf3A 7.0 ❑ Without Comments As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire revention Bureau for conformance with current City Erandards. Acceptance is subject to errors and oimissions which do not authorize violations of adopted ;t.andards and ordinances. Tte responstiility for the adequacy of design rests tote:: ;vIth the designer. additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. sinal acceptance is subject to field test and inspection by Tne Tukwila Fire Prevention Bureau. Date: 61- �- By: r SH -ET \UM3ESHEET TITLE TA -01 SYSTE v I\FOv1ATION FA -02 TYPICAL WHI\G A\ D V O U NTI \G DETAILS FA -03 SYSTEv CALCULATIO\S A\D SINGLE LINE I IAG AM FA -04 THE ALARI/ SYSTE V PLA\ SHEET INDEX WISE SCHEDULE AND CO\SUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKED P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSER\'ED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE 'KITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTDRS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PRCVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 1 (EX) 1 (EX) 1 (EX) 6 (EX) 3 (EX) SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT DETECTOR AD2-P W/ SIEMENS DUCT HOUSING (EXISTING -RELOCATED) HFP-1 1 DET. VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH (EXISTING -RELOCATED) TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY (EXISTING -RELOCATED) HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE (EXISTING -RELOCATED) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE (EXISTING -RELOCATED) ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A NI/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A NI/A v y 2 064 CO a` 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I C) 0 DESCRIPTION SHOP DRAWINGS DATE N Z N 0) 0 2 aaaaa SYMBOLS LEGEND NORDSTROM 3 L VE_S 171.275« Mrvk fi macys LEVELS TUKWILA FIRE DEPARTMENT Please call 205-575-4407 and give this Fire Permit No. /D- - F-aia- and exact address for shut- down hutdown or restoration approval. BLIEIZ TAX SI'," 1 ECSA- C =x�rs PAPAYA CLOTHING #328 WIRE DESIGNATION GENERAL NOTES SITE PLAN rl • JCPenney Lii PAID SEP o 4 21112 .nUKWILA FIRE Cc_ AO3 0 0 W } C,) /SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09 / 17/ 12 BACKROUND PLAN PROVIDED BY: 1.0B NUMBER: Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60NZ - DEDICATED EMERGENCY NOTE FOR ADC4110NAL SPECIRCADENS SEE PRODUCT DOQAIENTATION. *CONTACT RATRIGS 4.0A 0 125VAC 4.0A 0 30VDC SHIELDS A ISOLATE FR01 GROUNDING TO NEXT ADDRESSABLE (+ TO DEVICE SP IF LAST DEVICE - FROM XLS CONTROL PANEL DR PREVIOUS ADDRESSABLE DEVICE O O GROUND ' I u HTRI—R 0 0 ref 0' 0' O ° O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE iLfLi GRD N I 01 z 0 II O PAD -3 00 INPUT INPUT TROUBLE NACI NAC2 NAC3 NAC4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - 0 (-) (+) 2 SPARE SPARE SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. VO (+) 0 WIRE DESIGNATION: NUM1BEROFCONDUCTORS SIZE TYPE COLOR CODE MISTED PAIR'MITH SHIELD #18 FPIIFPLR RED (JACKET) *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O r GROUND L © 0 0 0 I� ®, I HTRI—R I DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. o (+), TO NEXT DEVICE OR (—) STOP IF LAST DEVICE DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FLED) F R 4.5 DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY + `J HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER6TING TEMPERA -WE: +32' F (O' C) TO 00' F (338' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —3,- FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) >-- DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION PATH DUCT HOUSINGS AD -11P OR AD-11XPR -- DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL 4:41;)> 00 O 0 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE / STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT 0 0 TO NEXT DEVICE 0 0 --CADDY BAR cJ SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: CD M 0 DESCRIPTION SHOP DRAWINGS DATE (NI N \ 0) 0 a aaaaa I z ao V 1- Z - r_-_Q� mz < W F— o W ZZ OCT) 1- W co <C M CL LL E- W D 0 Z 0 0 z c� z J U (S.-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/17/12 BACKROUND PLAN PROVIDED BY: .1OB NUMBER: SHEET FA -02 ACP ADD-ONS Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps PAP YA C�►TI"lN. x � { .,.. s i � ` EX1 STING SIEMENS PAD -.3 Si nal Extender Panel Batte Lc €cl :C llculatr011S DESCRIPTION SHOP DRAWINGS Current Load. ... ,Standb y: _ Mann. N N 0 0 2 aaaaa Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW ©15CD 15 0.0875 al -MC -CW ©30CD 8 0.131 ZH-MC-CW @75CD 4 0.222 ZH-MC-CW @95CD 5 0.292 1.460 ZH-HMC-CW @115CD 0.371 ZR -MC -CW ©15CD 11 0.069 0.759 ZR -MC -W ©15CD 0.064 0.03 Amps 2.249 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 2.249 Amps For 5 Minutes` 0.189 Amp -hours 25% Derating= 1.136 Amp -hours Total System Current Load: 1.136 Amp -hours Battery Pair to be Used 12VDC; Amp -h©urs : ?.SAH Notification Appliance Circuit Detail PROJECT: PAPAYA CLOTHING Panel: I PAD -3 BPS Date: September 20, 2012 Wire Resistance 2.58 CURRENT TOTAL= 1523.00 IZH-MC-CW ©15cd ZH-MC-CW z@30cd Z1-171111C-CWry @75cd ZH-MC-CW @95cd 1Z1 -1 -MC -CW @115cd 3 ZR -MC -CW @15cd DEVICES 16 87'„ 131 2221_, 292 371; 69 TOTAL mA=" Total Wire Resistance (R ) Total Device Load, Amps (I jVoltage Drop (E ) EOL Voltage 222. 0. _..... 207 647; 14 215 23.28; !(WL*2)*(Rift): (Totai Cct Load): 1(E=I*R) 24 647 1.11 0.65 0.72 23.28 ZH-MC-W @15cd ZH-NEC W �@3ocd ZH-MC-W @75cd ZH-MC-W @95cd `MBDC-10 ZR -MC -W @16cd EE DEVICES 13 78 ft3 195; 292 28 '64' TOTAL mA=j Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 0. 0 876 14 304 23.62: 876 ( WL* 2)*(Rift): (Ttita{. Cct Load) 1(E=I**R) 21.6-E) 1.57 0.86 1.37 20.23 SYSTEM CALCULATIONS TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP S S S S2-1 S2-2 S2-3 95cd 95cd 95cd EOL S2 S1-1 15cd S1-2 75cd 15cd S1-3 TSM S1-4 15cd S1-5 15cd S1-6 30cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. cc 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE N N 0 0 2 aaaaa 0 z o z �— <C W I- wzz cc cn _ LcNti �U I- cc 0 0 w z J W J 0 z C-) 0 C/) z 0 F— U W E-- C1� C!) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/17/12 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM JOB NUMBER: % SHEET FA -03 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved GENERAL NOTES: ALL FIRE ALARM DEVICES ARE EXISTING THAT WERE RELOCATED. FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-3 ?L( 15cd j.•.•(( r S1-4 15cd 7,7/_LCL/_Thi_'/. .ZA/„! v. /-V /._l am:/,i viii'i ././_ll_ I N // f - ✓i ;,,A. -,:.:";::i.:_,-,2_1/1 / ;/ u / / S1-5 15cd AS k YJ. S1-6 30cd ..•-- EOL S Dl S2-1 95cd ^, S2-2 95cd S / FIRE ALARM SYSTEM PLAN S2-3 95cd EOL S2 II *44 ca, 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 1 0 m 0 DESCRIPTION SHOP DRAWINGS W F— a C: N \ N \ 0) 0 2 aaaaa icCALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/ 17/1 2 BACKROUND PLAN PROVIDED BY: JOB NUMBER: J SHEET FA -04 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved \ J 328 SOUTHCENTER MALL ASSOCIATED PERMITS 12-F-212 4itt SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. StAd l **PLEASE PRINT** 1 ` oingCo. Assessor's Tax No.: Site Address: (�t,A �.A 11�.1J�t (�v�`� G� &i t umber: Tenant Name: ‘0(-, _ 1,0-1/111r)(-\ Property Owner's Name: V _ QM \ Pel Ck LLC Mailing Address%Q qt (-J ' iVd ' t'ct ' 1 I 1/1_, LA° IN ` (t2-; New Tenant?\tit- Yes ❑ - No CONTACT PERSO N -if there are questions about the submittal. Name:/Y 1.1 Ve t, Company Name: C -'ix" SAX-l.C/"r Mailing Address: 1T W7) 1X V7 t ALJ, - S �` J ,City E-mail Address: �v l., ` (� � U C&J'(c1(c 1 s /V City State Zip Day Telephone: ' I< L "LI Z �- • t G . 5/ ` aq ak lj7umber: I sneirq ao Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Lu v c) 1 0_641 (1g y,c, ,aii( VV\ -- PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING' R OR AUT RAZED AGENT: Signature: nJ Print Name:,Y l 1 ICi Plan Permit App.doc Date:/(2-1-4 / l Day TelephoneaL '02,t/ te646X29 5/14/10 TFD FP Form 8 IRE T SH ffiliml I N" IY DDITION N NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to. commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee a.ntd termination of the testing, jAf3A 7.0 ❑ Without Comments As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire revention Bureau for conformance with current City Erandards. Acceptance is subject to errors and oimissions which do not authorize violations of adopted ;t.andards and ordinances. Tte responstiility for the adequacy of design rests tote:: ;vIth the designer. additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. sinal acceptance is subject to field test and inspection by Tne Tukwila Fire Prevention Bureau. Date: 61- �- By: r SH -ET \UM3ESHEET TITLE TA -01 SYSTE v I\FOv1ATION FA -02 TYPICAL WHI\G A\ D V O U NTI \G DETAILS FA -03 SYSTEv CALCULATIO\S A\D SINGLE LINE I IAG AM FA -04 THE ALARI/ SYSTE V PLA\ SHEET INDEX WISE SCHEDULE AND CO\SUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKED P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSER\'ED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE 'KITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTDRS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PRCVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX 1 (EX) 1 (EX) 1 (EX) 6 (EX) 3 (EX) SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT DETECTOR AD2-P W/ SIEMENS DUCT HOUSING (EXISTING -RELOCATED) HFP-1 1 DET. VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH (EXISTING -RELOCATED) TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY (EXISTING -RELOCATED) HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE (EXISTING -RELOCATED) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE (EXISTING -RELOCATED) ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A NI/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A NI/A v y 2 064 CO a` 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: I C) 0 DESCRIPTION SHOP DRAWINGS DATE N Z N 0) 0 2 aaaaa SYMBOLS LEGEND NORDSTROM 3 L VE_S 171.275« Mrvk fi macys LEVELS TUKWILA FIRE DEPARTMENT Please call 205-575-4407 and give this Fire Permit No. /D- - F-aia- and exact address for shut- down hutdown or restoration approval. BLIEIZ TAX SI'," 1 ECSA- C =x�rs PAPAYA CLOTHING #328 WIRE DESIGNATION GENERAL NOTES SITE PLAN rl • JCPenney Lii PAID SEP o 4 21112 .nUKWILA FIRE Cc_ AO3 0 0 W } C,) /SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09 / 17/ 12 BACKROUND PLAN PROVIDED BY: 1.0B NUMBER: Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60NZ - DEDICATED EMERGENCY NOTE FOR ADC4110NAL SPECIRCADENS SEE PRODUCT DOQAIENTATION. *CONTACT RATRIGS 4.0A 0 125VAC 4.0A 0 30VDC SHIELDS A ISOLATE FR01 GROUNDING TO NEXT ADDRESSABLE (+ TO DEVICE SP IF LAST DEVICE - FROM XLS CONTROL PANEL DR PREVIOUS ADDRESSABLE DEVICE O O GROUND ' I u HTRI—R 0 0 ref 0' 0' O ° O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE iLfLi GRD N I 01 z 0 II O PAD -3 00 INPUT INPUT TROUBLE NACI NAC2 NAC3 NAC4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - 0 (-) (+) 2 SPARE SPARE SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. VO (+) 0 WIRE DESIGNATION: NUM1BEROFCONDUCTORS SIZE TYPE COLOR CODE MISTED PAIR'MITH SHIELD #18 FPIIFPLR RED (JACKET) *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O r GROUND L © 0 0 0 I� ®, I HTRI—R I DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. o (+), TO NEXT DEVICE OR (—) STOP IF LAST DEVICE DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FLED) F R 4.5 DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY + `J HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER6TING TEMPERA -WE: +32' F (O' C) TO 00' F (338' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —3,- FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) >-- DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION PATH DUCT HOUSINGS AD -11P OR AD-11XPR -- DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL 4:41;)> 00 O 0 SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE / STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT 0 0 TO NEXT DEVICE 0 0 --CADDY BAR cJ SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: CD M 0 DESCRIPTION SHOP DRAWINGS DATE (NI N \ 0) 0 a aaaaa I z ao V 1- Z - r_-_Q� mz < W F— o W ZZ OCT) 1- W co <C M CL LL E- W D 0 Z 0 0 z c� z J U (S.-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/17/12 BACKROUND PLAN PROVIDED BY: .1OB NUMBER: SHEET FA -02 ACP ADD-ONS Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps PAP YA C�►TI"lN. x � { .,.. s i � ` EX1 STING SIEMENS PAD -.3 Si nal Extender Panel Batte Lc €cl :C llculatr011S DESCRIPTION SHOP DRAWINGS Current Load. ... ,Standb y: _ Mann. N N 0 0 2 aaaaa Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW ©15CD 15 0.0875 al -MC -CW ©30CD 8 0.131 ZH-MC-CW @75CD 4 0.222 ZH-MC-CW @95CD 5 0.292 1.460 ZH-HMC-CW @115CD 0.371 ZR -MC -CW ©15CD 11 0.069 0.759 ZR -MC -W ©15CD 0.064 0.03 Amps 2.249 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 2.249 Amps For 5 Minutes` 0.189 Amp -hours 25% Derating= 1.136 Amp -hours Total System Current Load: 1.136 Amp -hours Battery Pair to be Used 12VDC; Amp -h©urs : ?.SAH Notification Appliance Circuit Detail PROJECT: PAPAYA CLOTHING Panel: I PAD -3 BPS Date: September 20, 2012 Wire Resistance 2.58 CURRENT TOTAL= 1523.00 IZH-MC-CW ©15cd ZH-MC-CW z@30cd Z1-171111C-CWry @75cd ZH-MC-CW @95cd 1Z1 -1 -MC -CW @115cd 3 ZR -MC -CW @15cd DEVICES 16 87'„ 131 2221_, 292 371; 69 TOTAL mA=" Total Wire Resistance (R ) Total Device Load, Amps (I jVoltage Drop (E ) EOL Voltage 222. 0. _..... 207 647; 14 215 23.28; !(WL*2)*(Rift): (Totai Cct Load): 1(E=I*R) 24 647 1.11 0.65 0.72 23.28 ZH-MC-W @15cd ZH-NEC W �@3ocd ZH-MC-W @75cd ZH-MC-W @95cd `MBDC-10 ZR -MC -W @16cd EE DEVICES 13 78 ft3 195; 292 28 '64' TOTAL mA=j Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 0. 0 876 14 304 23.62: 876 ( WL* 2)*(Rift): (Ttita{. Cct Load) 1(E=I**R) 21.6-E) 1.57 0.86 1.37 20.23 SYSTEM CALCULATIONS TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP S S S S2-1 S2-2 S2-3 95cd 95cd 95cd EOL S2 S1-1 15cd S1-2 75cd 15cd S1-3 TSM S1-4 15cd S1-5 15cd S1-6 30cd EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. cc 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE N N 0 0 2 aaaaa 0 z o z �— <C W I- wzz cc cn _ LcNti �U I- cc 0 0 w z J W J 0 z C-) 0 C/) z 0 F— U W E-- C1� C!) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/17/12 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM JOB NUMBER: % SHEET FA -03 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved GENERAL NOTES: ALL FIRE ALARM DEVICES ARE EXISTING THAT WERE RELOCATED. FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP S1-3 ?L( 15cd j.•.•(( r S1-4 15cd 7,7/_LCL/_Thi_'/. .ZA/„! v. /-V /._l am:/,i viii'i ././_ll_ I N // f - ✓i ;,,A. -,:.:";::i.:_,-,2_1/1 / ;/ u / / S1-5 15cd AS k YJ. S1-6 30cd ..•-- EOL S Dl S2-1 95cd ^, S2-2 95cd S / FIRE ALARM SYSTEM PLAN S2-3 95cd EOL S2 II *44 ca, 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 1 0 m 0 DESCRIPTION SHOP DRAWINGS W F— a C: N \ N \ 0) 0 2 aaaaa icCALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/ 17/1 2 BACKROUND PLAN PROVIDED BY: JOB NUMBER: J SHEET FA -04 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved \ J