Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 344 SOUTHCENTER MALL - AT&T MOBILITY - PERMITS AND PLANS
344 SOUTHCENTER MALL ASSOCIATED PERMITS 16-F-162 08-F-148 08-S-100 tggni SITE LOCATION 2 L L\ Site Address:W Soutcenter Mall Suite Number: Floor: CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Tenant Name: At&T Mobile New Tenant? ❑ - Yes 0- No Property Owner's Name: Westfield Shopping Center Mailing Address: fag Southcenter Mall, Tukwila, WA 98188 Z:b0o City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 2.349.5889 Company Name: Guardian Security Mailing Address: 1743 First Ave S, Seattle, WA 98134 kveliz@guardiansecurity.com City State Zip E-mail Address: Fax Number: 206.374.2852 Contractor's City of Tukwila NICET III number: Business License number: GUARDSS233K5 Exp. 09/30/2016 Total number of new/relocated devices or sprinkler heads: 9 Valuation of Project (contractor's bid price): $ 3,600. Scope of Work (please provide detailed information): Fire Alarm System Alteration: Add 9 device. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING WNER OR AUT RIZED AGENT: Signature: C _ Date: Print Name: Karma Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 8/22/14 TFD FP Form 8 A ori FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: AT & T 344 Southcenter Mall Permit No.: 08-S-100 Date: March 31, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. 11 u)fcS"i Job Number KS0300 c.� a - Report Description: .'w„- _ -::;:p ;.> _ ,; - e , AT&T Zone Ti Job _: „ - ..-.. ., _ esr _rt,:,T�:. `i�{�„ �•x,?I"i.,,>',; ."tet- : .. ...,« :. `,SY:'� Fc: -_ + es-S;:a pp > , ,. .. ,:n- - :: Vii..' ^t:",i:"N:. sV- gr�`;x;`•'I _, a Job Number a_, - �a+ . -- ;>3: - `r KSO3OO _.. .....'.'�`� kt ,da: . . ..." . . Design Engineer Adam Kanter --r1ob-Name—__— ---_ --_—__ — AT&T Address 1 State Certification/License Number WESTESF136QF 344 Southcentner Mall Address 2 A City of Tukwila City Job Site South center Mall Tukwila State Wa Zip Code 98188 Drawing Name FP-1.cad S" stem:'.."r:,. :.-,. Ar Most Demanding Sprinkler Data , ...;r('$C",::•a,'J.5`_ r_"t:'r;'''t.'-' r 5.6 K -Factor 26.00 at 21.556 Hose Allowance At Source .is _ _ Occupancy '"•' • ^n -�.... . Ordinary Group II 250.00 Additional Hose Supplies Density 0.20gpm/ft2 Area of Application 1130.00ft2 (Actual 1130.39ft2) Node Flow(gpm) Number Of Sprinklers Calculated 14 Coverage Per Sprinkler 130.00ft2 roction 0°y2� et ,�t� CFrtq: Total Hose Streams 250.00 O , s'"' Oj„ ; �,,; h System Flow Demand Total Water Required (Including Hose Allowance) a, { ,h 399.88 649.88 'f;i i A. er`', Maximum Pressure Unbalance In Loopsil 0.000 .�: \L%d�'�y`'�i' Beat —T Maximum 26.80 between nodes 161 and 229 36l0r Maximum Velocity Under Ground 1.51 between nodes 1 and 417 Ss —,.-, Volume capecity of Wet Pipes 2453.38ga1 I Volume capacity of Dry Pipes 0.75ft3 Node 1 Hose Flow (gpm) Static (psi) Residual © Flow (psi) (gpm) Available @ Total Demand (psi) (gpm) Required (psi) Safety Margin 250.00 140.000 20.000 10900.00 139.349 � 649.88 92.711 6.63 46.638 *,t fir' - `:--'.H`'er icer ",'•tet-:;.�: ._a Contractor Name Contractor Number KSO300 Contact Name Adam Kantner ,._ .• ' - ntact Title ceProject Manager Western States Fire Protection Address 1 Phone 425.881.0100 Extension 7102 180th Ave Ne, Suite A-105 Address 2 FAX 485.736.9032 City E-mail Redmond State WA Zip Code 98052 Web -Site er Data Job Number:50300 K Report Description: AT&T Zone T1 ��.; S:ia;lrn .a ,. tfilOW 11 98 ti . ;�;��:: .........,, Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler _ _ 109 30.05 26.0D__ _- _ _ _ -5.6 - 28,798 Sprinkler 113 34.31 26.00 5.6 37.537 Sprinkler 110 30.32 26.00 5.6 29.309 Sprinkler 105 27.70 26.00 5.6 24.473 Sprinkler 106 28.54 26.00 5.6 25.978 Sprinkler 112 33.41 26.00 5.6 35.602 c Sprinkler 101 26.00 26.00 5.6 21.556 Sprinkler 104 27.65 26.00 5.6 24.386 Sprinkler 114 33.58 22.40 5.6 35.947 Sprinkler 102 25.07 24.00 5.6 20.040 Sprinkler 103 27.12 26.00 5.6 23.451 Sprinkler 107 24.09 20.00 5.6 18.502 Sprinkler 108 24.40 20.00 5.6 18.983 Sprinkler 111 27.64 20.00 5.6 24.363 er Data Job Number: KS0300 Node Elevation(Foot) Fittings Pressure(psi) INcpViL Discharge(gpm) LiCJtoltpuuII. /Alai cone 1 _1 127 14-2 P0(26-4) 78.805 161 15-3 ------ 32..087-- - 229 15-3 2P0(8-0) 53.182 230 15-3 2P0(8-0) 50.738 232 15-3 P0(8-0) 50.485 274 15-3 P0(5-0) 31.054 276 15-3 P0(5-0) 40.288 295 15-3 P0(5-0) 31.621 353 1-11 85.506 394 15-3 P0(5-0) 26.099 417 5-8 BFP(-4.500) 88.420 426 1-11 P0(37-8%) 85.428 436 15-3 P0(5-0) 27.776 469 15-3 P0(5-0) 38.235 486 15-3 P0(5-0) 22.952 489 15-3 P0(5-0) 26.001 495 15-3 E(2-0) 37.614 499 15-3 P0(5-0) 21.155 502 15-3 P0(5-0) 24.960 505 15-3 P0(5-0) 20.865 508 15-3 E(2-0) 20.850 511 15-3 E(2-0) 24.793 109 12-0 Spr(-28.798) 28.798 30.05 113 8-0 Spr(-37.537) 37.537 34.31 110 12-0 Spr(-29.309) 29.309 30.32 105 12-0 Spr(-24.473) 24.473 27.70 106 12-0 8-0 Spr(-25.978) Spr(-35.602) 25.978 35.602 28.54 33.41 112 101 12-0 Spr(-21.556) 21.556 26.00 104 12-0 Spr(-24.386) 24.386 27.65 114 8-0 Spr(-35.947) 35.947 33.58 102 12-0 Spr(-20.040) 20.040 25.07 103 12-0 Spr(-23.451) 23.451 27.12 107 15-0% Spr(-18.502) 18.502 24.09 108 15-0% Spr(-18.983) 18.983 24.40 111 15-0% Spr(-24.363) 24.363 27.64 1 -4-0 S 92.711 399.88 Pipe Type Diameter Downstream Elevation Upstream rrr • •-Route 1 DR 101 486 Flow Velocity HWC Friction Loss Discharge K -Factor Pt Pn Fittings Job Number: KS0300 Report Description: AT&T Zone T1 1.049 12-0 15-3 CM 1.610 486 15-3 394 15-3 Q=26.00 9.65 Length Eq. Length Total-Lengt Pressure Summary C=120 q=26.00 K=5.6 0=99.56 15.69 21.556 22.952 C=120 CM 1.610 394 15-3 274 15-3 Q=127.26 20.06 22.952 26.099 0.211435 Spr(-21.556) 2E(2-0), P0(5-0) 0.314656 C=120 CM 1.610 274 15-3 229 15-3 Q=157.31 24.79 26.099 31.054 0.495550 C=120 CM 2.469 229 15-3 161 15-3 Q=399.88 26.80 31.054 53.182 0.733529 P0(8-0) C=120 CM 4.260 161 15-3 127 14-2 Q=399.88 9.00 53.182 72.087 C=120 CM 6.357 127 14-2 426 1-11 Q=399.88 4.04 72.087 78.805 C=120 FM 8.329 426 1-11 353 1-11 MS 353 417 Q=399.88 2.35 78.805 85.428 C=120 10.020 1-11 5-8 Q=399.88 1.63 85.428 85.506 C=120 UG 10.400 417 5-8 1 -4-0 Gi Route 2 Q=399.88 1.51 85.506 88.420 C=140 88.420 0.513633 fT(10-9%) 0.036058 2P0(26-4), 2Ee1(5-3), fEE(3-5) 0.005133 4- Pf 2.798 9-t Pe -1.402 13- Pv 10-I Pf 3.147 Pe 10-r Pv 10-4 Pf 4.956 Pe 10-s Pv 22- Pf 22.128 8-i Pe 30-2 Pv 26-i Pf 18.905 10-9Y. Pe 36-9Y Pv 3fE(10-0), E(17-7), fT(25-0), CV(40-3), GV(3-9%), P0(37-8% 0.001377 2fE(16-0) 0.000560 106- 66-7 173-3 102-1 154-4 256-5 Pf 6.248 Pe 0.470 Pv Pf 1.316 Pe 5.307 Pv 3LtE(16-0), BV(19-0), BFP(-4.5 0.000351 00) 92.711 3LtE(25-6), E(35-1), 2EE(17-6%), S 24-8Y Pf 0.078 32- Pe 0.000 56-8Y Pv 20- 67- 87- Pf 4.549 Pe -1.635 Pv 113-1Pf 0.091 146- Pe 4.200 259-9'/ Pv DR 1.049 0=25.07 9.31 C=120 0.197642 102 12-0 q=25.07 K=5.6 20.040 Spr(-20.040) 499 15-3 21.155 2E(2-0), P0(5-0) CM 1.610 0=73.56 11.59 C=120 0.179745 499 15-3 486 15-3 Route 3 DR 103 502 CM 502 489 21.155 22.952 1.049 12-0 15-3 Q=27.12 10.07 3-9 9-0 12-9 10-0 10-0 Pf 2.517 Pe -1.402 Pv Pf 1.797 Pe Pv C=120 1.610 15-3 15-3 q=27.12 K=5.6 Q=54.76 8.63 23.451 0.228576 Spr(-23.451) 24.960 2E(2-0), P0(5-0) C=120 24.960 26.001 CM 1.610 Q=82.41 12.99 C=120 0.221825 489 15-3 26.001 436 15-3 27.776 CM 436 295 0.104128 1.610 15-3 15-3 0=110.96 17.49 C=120 0.384540 27.776 31.621 CM 1.610 0=141.27 22.26 C=120 0.601205 295 15-3 31.621 230 15-3 50.738 P0(8-0) CM 2.469 0=242.57 16.26 C=120 0.203719 230 15-3 50.738 229 15-3 53.182 m► Route 4 DR 1.049 0=27.65 10.27 C=120 0.236986 104 12-0 q=27.65 K=5.6 489 15-3 ®r Route 5 DR 105 394 Route 6 DR 106 436 1.049 12-0 15-3 Q=27.70 10.28 3-9 Pf 2.911 9-!1 Pe -1.402 12-9 Pv 10-0 Pf 1.041 Pe 10-0 Pv 8-0 Pf 1.775 Pe 8-0 Pv 10-0 Pf 3.845 Pe 10-0 Pv 23-9% Pf 19.116 8-0 Pe 31-9% Pv 12-0 Pf 2.445 Pe 12-0 Pv 24.386 Spr(-24.386) 26.001 2E(2-0), P0(5-0) 3-9 Pf 3.018 9-d Pe -1.402 12-9 Pv q=27.70 K=5.6 C=120 24.473 26.099 e� Route 7 0.237772 Spr(-24.473) 2E(2-0), P0(5-0) 1.049 0=28.54 10.60 C=120 0.251269 12-0 q=28.54 K=5.6 25.978 Spr(-25.978) 15-3 27.776 2E(2-0), P0(5-0) Pf 3.028 9- Pe -1.402 12- Pv 3-9 Pf 3.200 9-d Pe -1.402 12-9I Pv (� Hydrap lic�An;alysis Job Number KS0300 Report Description: AT&T Zone T1 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream -t04J Eq. Length Total_Length Summary DR Q=24.09 8.94 C=120 0.183572 _ 4-41/2 107 15-0% q=24.09 K=5.6 18.502 Spr(-18.502) 505 15-3 20.865 2E(2-0), P0(5-0) 9-0 13-4% Pf 2.458 Pe -0.096 Pv CM 1.610 0=48.49 7.64 C=120 0.083142 3-6 505 15-3 20.865 499 15-3 21.155 3-6 Pf 0.290 Pe 0.000 Pv Oa Route 8 DR 1.049 0=24.40 9.06 C=120 0.187983 4-5% 108 15-0% q=24.40 K=5.6 18.983 Spr(-18.983) 508 15-3 20.850 3E(2-0) 6-0 10-5% Pf 1.962 Pe -0.096 Pv CM 1.610 0=24.40 3.85 C=120 0.023337 0-7% 508 15-3 20.850 505 15-3 20.865 0-7% Pf 0.015 Pe Pv Route 9 DR 1.049 0=30.05 11.16 C=120 0.276402 4-3 9-0 13-3 Pf 3.658 Pe -1.402 Pv 109 12-0 q=30.05 K=5.6 28.798 Spr(-28.798) 274 15-3 31.054 2E(2-0), P0(5-0) Route 10 DR 1.049 0=30.32 11.25 C=120 0.280929 4-3 9-0 13-3 Pf 3.724 Pe -1.411 Pv 110 12-0 q=30.32 K=5.6 29.309 Spr(-29.309) 295 15-3 31.621 2E(2-0), P0(5-0) a Route 11 DR 1.049 0=27.64 10.26 C=120 0.236782 0-2% 2-0 2-2% Pf 0.526 Pe -0.096 Pv 111 15-0% q=27.64 K=5.6 24.363 Spr(-24.363) 511 15-3 24.793 E(2-0) CM 1.610 0=27.64 4.36 C=120 0.029396 5-8 5-8 Pf 0.167 Pe -0.000 Pv 511 15-3 24.793 502 15-3 24.960 a* Route 12 DR 1.049 0=33.41 12.40 C=120 0.336310 8-1% 9-0 17-11/2 Pf 5.764 Pe -3.130 Pv 112 8-0 q=33.41 K=5,6 35.602 Spr(-35.602) 469 15-3 38.235 2E(2-0), P0(5-0) CM 1.610 0=66.99 10.56 C=120 0.151189 13-7 13-7 Pf 2.052 Pe Pv 469 15-3 38.235 276 15-3 40.288 CM 1.610 Q=101.30 15.96 C=120 0.324923 23-4% 8-0 31-4% Pf 10.197 Pe Pv 276 15-3 40.288 232 15-3 50.485 P0(8-0) CM 2.469 0=101.30 6.79 C=120 0.040499 6-3 6-3 Pf 0.253 Pe Pv 232 15-3 50.485 230 15-3 50.738 as Route 13 DR 1.049 0=34.31 12.74 C=120 0.353185 7-81 Pf 5.881 9-0; Pe -3.130 16- Pv 113 6-0 q=34.31 K=5.6 37.537 Spr(-37.537) 276 15-3 40.288 2E(2-0), P0(5-0) a* Route 14 DR 1.049 0=33.58 12.46 C=120 0.339323 8-11/ 6- 14-11/ Pf 4.797 Pe -3.130 Pv 114 8-0 q=33.58 K=5.6 35.947 Spr(-35.947) 495 15-3 37.614 3E(2-0) CM 1.610 0=33.58 5.29 C=120 0.042126 14-9 14-9 Pf 0.621 Pe Pv 495 15-3 37.614 469 15-3 38.235 Equivalnt:Pipe Lengths-C(.Ualves anti Fittings (C=120,only},,::II CValue-Multiplier (Actual Inside Diameter 487 Value Of C 100 130 140 150 Schedule 40 Steel Pipe Inside Diameter ) = Factor Multiplying Factor 0,713 1.16 1.33 1.51 111 Hydraullc: Analysis Pipe Type Diameter Downstream Elevation Upstream Pipe: Type::Legend Flow Discharge Velocity HWC K -Factor Pt Friction Loss Pn Fittings Job Number: KS0300 Report Description: AT&T Zone T1 UnitS-Legen AO Arm -Over Diameter BL Branch Line Elevation CM Cross Main Flow DN Drain Discharge DR Drop Velocity DY Dynamic Pressure FM Feed Main Length FR Feed Riser Friction Loss MS Miscellaneous HWC OR Outrigger Pt RN Riser Nipple Pn SP Sprig Pf ST Stand Pipe Pe UG Underground Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe Length Pressure Eq, Length Summary Total Length— - : i tings Legend, ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22'/z Elbow f Flow Device FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 150 135 120 105 Static Pressure 140.000 Supply at Node 1 Job Number: KS0300 Report Description: AT&T Zone T1 -649.88 with hose streams 90 -99.88 @ 92.711 E 75 N N d 60 System demand curve 45 30 15 0 10900.00 @ 20.000 IIIL IIIIIIILL 11111/111 I1 11 L1 LJ 1 111111111 91002200 3300 4400 Hydraulic Graph Supply at Node 1 Static Pressure 11111111/ I l I I 1 I I I I 5500 6600 I I I 1 I I 1 1 7700 Water flow, gpm 111111111 8800 1 I I 1 I 1 I 1 1 9900 11000 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.349 @ 649.88 System Demand 399.88 @ 92.711 System Demand (Including Hose Allowance) 649.88 @ 92.711 Wr' E VICINITY MAP SCALE: NTS General Notes Suite# 344) 1. Western States Fire Protection to add new pendent heads new uptight heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system onl in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. ;;7 I; 7 i"w a 61 RISER DETAIL HYDRAULIC REFERENCE ONLY YS'+!+9 •tR at SCALE Without Comment S As Noted In Red Per The Attached Letier t i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is urie t to errors and omissions which do not authorize violations of adopted t atanaaros and ordinances. The rc oon_ibility for the t edequacy of design rests totally with the designer. Additions, deletions or revisions to those drawings atter !aiS date iIi :0'd tnis acceptance cn.w ii require a resubmittal of revised drawings for subsequent approval. sinal acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: `1-'.J CT) By: 4asantrls. I uKWILA FIRE DEPARTME ' . Please call: 575-440Z and give this job No. 02-S- i(0° :nd exact address for shute 1, it or restoration aporov*% NOTICE Weld stamps must be inspected before pipe is hung. a n =t paint piping pr r to hydrostatic test EXISTING 4" Ti MAIN le=I®r® 71 eIT1=I®®®ee• II= dINeIm U EXISTING 4" T1 MAIN rem ® e e® =Te= use= ems ® em It= ®®I= = Ie:e teeeT ®® START NEW MAIN HERE 5-1 X1/2 A`h inVn AT&T Remote Area: Retail # 344 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 DENSITY .20 GPM / Ft' for 1130 SPRINKLER Reliable Model G4A Ft' Ft' ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION': STATIC 140 RESIDUAL 20 FLOW AT BASE OF RISER, SYSTEM REQUIRES: 402 GPM @ 85.8 10900 PSI PSI GPM PSI ' At time of Design 15'-0" CLG.=32% AREA REDUCTION Ci) �0� 1 3-5 "• Ordinary Group II.0.20gpm/ft2 for 1130.00ft2 FIRE SPRINKLER SYSTEM 1/8"=1'-0" TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS MOUNTING BRACKET REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE FIG. 909 SWIVEL SWAY BRACE FITTING OI 3/9' KWIK BOLT (2 114' EMBED LENGTH) FIG.1000 "FAST CLAMP' SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE FIG. 4A PIPE CLAMP FOR SWAY BRACE 3/9' KWIK BOLT (2 1W EMBED LENGTH) FIG. 909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT LATERAL BRANCHLINE RESTRAINT BRACE PIPE cittd) NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III HILT, Kwik Bolt II Rod Coupling Cut Rod Lgth Rounded to Nearest Inch All Thread Rod 'FYI Swivel Ring Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE EARTHQU 446-11 * IBRACINI i. - 2008 SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL APPROVAL: City of Tukwila 4 -WAY EARTHQUAKE BRACE R5415 48 5.6 Pendent yin White 155°F Rel G4A Concealer 0 HYDRAULIC REFERENCE POINT R3625 1 5.6 Upright %i' Brass 155°F Rel F1 FR SSU CONT. NO.: KS0300 HANGER SYMBOL BRANCHLINE RESTRAINT Total = 49 DRAWN BY: Adam Kantner SPRK. ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 04/01/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF138QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/DECATUR/DENVER/DULUTH/HOUSTON/KANSAS CITY LOS VEGAS/MINNEAPOLIS/PHOENIX/PORTLAND/ RAPID CITY/SLPAUL/SALT LAKE CITY/SEATTLE Phone:425-881-0100 Fax:425-881-3030 Tukwila Fire a CB Bovenkamp, ARCHITECT: Adam Kantner w w z C7 Z w CB Bovenkamp, Inc CONTRACTOR: ,775 C/ yrs%.54 - AT&T 344 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SHEE FP OF 1 T 1 ILE -- D A F rAR K S D TE SH T ECTOR ADE. an Y� „IITIDDITIONON SHEET NUIV3ESHEET TITLE FA -01 SYSTEV INFHMATIO\ FA -02 TYPICAL WRING A\3 VI O U \ TI \G DETAILS FA -03 FRE ALAv SYSTEfv P _A\ TUKWILA FIRE DEPARTMENT se3s (.n3205-5754-407 205-57�f-� 5- � 't0Z and give W.0 1 1: x ^ Fre Permit t o enc' shut- down [ �'�C°1�,pproval. SHEET INDEX Without Comments ❑ As Notea in Re -4 ® Per The Attached Letter These plans have. Been reviewed by The Tukwila Fire Prevention Bureau -or conformance w -i fl current City standards. Accu:•)^ce is subject to errors and omissions whici; r.7> nor authorize violations of adopted standards anu c1f.!Ts-inces. The responsibility for the adequacy of des.. {sats totally with the designer. Additions, deinc, revisions to these drawings after this date wilt ti_,c,;c, , i.,:: .ceptance and will require a resubmittal r` r z!v e(t drawings for subsequent approval. Final acceptance 1E. subject to field test and Inspection by The Tukwila Fire ,'i eventior: Bureau. Date: 8.-10 -oto 8v: .5-1) WIRE SC NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must he presented to the ; nsf)cctor ^rior to commenceme: « cr Acceptance Testing of any Fire Marin and Detection Systems, Failure of test will result in a Re -inspection Fee and termination of the ting DULE AND CO\DUIT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JJRISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX 3 3 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER E POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP. DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM EX--) E STROBE (EXISTING) EX ZR -MC -CW SIEMENS EXISTING CEILING 8E FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND R NORDSTROM 3 LEVELS ;1.275sf �3 Ui(Y' :•a53-sCT e1 macy. 4 LEv=LS _".4C7sf Y iC'UP.E srPlE. . • AT&T MOBILE #633 • « .00T Cf „acs s acnesa I - RE;Tuaon Y -s.- C RET+t Rn y 4 .: tet - -.• 55 a- Lf_ • 0. PAM SITE PLAN RTA � . I, , I -- JCPenney cx _AHs pp lD AtlG -a 2416 TUK\NI� A FIRE .44 cc z 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 08/04/16 2aaaaa z O 0 c O _ co W o2z I- <c f - w I- t� zz Lux � j 1 O C/) 1- TOC. cc 1z) W CC7 CO Z H (1) �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/04/1 6 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 17305-1) A _ P�iD Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved FA -01 SHEET THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDI11ONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ DEDICATED EMERGENCY l TUBE OUTLET--\ SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE: FOR ADDmcNAI. SPECIRCATIONS SEE PRODUCT DOGAIENTAI14N. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC Iff i1E All S D nit 1) TO NEXT ADDRESSABLE (+ DEVICE STIPIF LAST DEVICE FROM XLS CONTROL PANEL (4 OR PREVIOUS ADDRESSABLE DEVICE O 0 r u m '1 HTRI—R 0 0 O O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C—CABLE C—CABLE GRD N L UY PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1— 1 2+ 2— 2 NC C NO + — + — + — + — + 0 0 0 0 a 0 Qpm 3.6k EOL (-) (+) NAC 4 CIRCUIT NAC 3 CIRCUIT NAC 2 CIRCUIT CEILIN TILE SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4° SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (-) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE -(+ FROM XLS CONTROL PANEL OR i+ PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH -- 0 (+) 1 GROUND 0 0 0 0 HTRI—R STATUS LED 0 N.0 0 COM c N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 MUSIC rTh HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY 0 HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL LAC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4,0A @ 125VAC) (4,OA @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERATURE; +32'F (0' C) TO 100' F 38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON—CONDENSING HFP-11 SMOKE DETECTOR —, —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (—) > DATA IN (+) > TO NEXT DEVICE OR END OF LINE DEVICE IS USED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR ,— DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL > TO NEXT ADDRESSABLE DEVICE TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE e TB1 0®0®Q 10 NO COM NC J EOLR •vvV 470 0 00 TO FAN SHUTDOWN TO NEXT e ADDRESSABLE DEVICE 0 0 io NO IS COM e HTRI-R NC ® 0 O TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTION BOX— MOUNTED ON \ CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT J O O O 0 TO NEXT DEVICE CADDY BAR E]I SMOKE DETECTOR------- \\— SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved • CC o zt V) CO 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: SWITCH + — INPUT LED TSM -1 0 00 TO FAN SHUTDOWN TO NEXT e ADDRESSABLE DEVICE 0 0 io NO IS COM e HTRI-R NC ® 0 O TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTION BOX— MOUNTED ON \ CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT J O O O 0 TO NEXT DEVICE CADDY BAR E]I SMOKE DETECTOR------- \\— SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved • CC o zt V) CO 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE tO O oo 0 z aaaaa z O 0 0 Qz co O0 EE Jr D 2z LAJ < H. W 0r W w 2: 17: 0 I-- CD DIL) U Dococi� 1 Li, `Cit ) W ,� MJ Cl) CC O I- x A W E-- 41C Fz O 0 Z C� Z J U �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/04/16 BACKROUND PLAN PROVIDED BY: �OB NUMBER:17305-12 r SHEET FA -02 SE SE HT -R TSM D 9 cp—D c= _ FIRE ALARM SYSTEM PLAN FLAG NOTES: DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. EXISTING BACK -OF -THE -HOUSE TENANT JUNCTION BOX. IZsa CC W ti • V) co ON 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 3 n DESCRIPTION SHOP DRAWINGS DATE 08/04/16 z 0 0 0 00 co _;(7,- W o 26 <11.1w 0 W�-- zz (/) U t= a U cc_1-1 � � dog d I W M J E-6 0 06 rSCALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/04/ 1 6 BACKROUND PLAN PROVIDED BY: \ 0B NUMBER:17305-1} ( SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved \ J ( I i^ FILE COPY Y TEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \UM3ESHEET TITLE FA -01 SYSTEIv \FONATIO\ FA -02 TYPICAL DETAILS - WRI\G A\D y \TI \ G FA -03 FRE ALARM FLOC) PLA\ FA -04 VALL SITE PLA\ A\ D CALC U LATI O \ S M ❑ ACC Without Comments As Noted In Red Per The Attached Letter owe -;•isusentommisatenvay '1 'I? i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for cor,iorrn_nce with current city I standards. Acceptance is t.ubisot to errors and • omissions vrh c h1 do not auihoci2se violations of adopted s';an0C-.ir0s rind c:::: ,:. ,c .... i o: isib i ty for the • designer. drawings atter will require a .isubfnif L,! for subsequent approval. }nal acceptance i•; :i! 1!')JP,('i to held test and inspection by T n• Tukwila Firs PrOvon'Lion Bureau. •Date: 1-1--)N 9 By: TUKWILA FIRE DEPARTMENT. Please call; 575-440Z and give this job No.0 -F") and exact address for shut, bt'wn or restoration approval Because of increased demand our nspecors' schedules are booked 3-7 days ahead. Therefore, you will need to cafl 206-575-4407 or email Firesnsprealuest@cLt(*wila.yva.us to schedule your inspections tions a minimum of 43 hours in advance of the date you want an inspection. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE A ND CONDUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS • SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2V STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET), A ANNUNCIAT❑R TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART No. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT,SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-12" .82 SQUARE INCH 2' 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO • DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE O\1 ADDRESSABLE LOOP 1 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY' SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED, NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NEPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY,:., TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE, SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY• GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COvPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. . 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH ' A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NEPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 2 6 2 SYMB L DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS! REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D, DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZMI REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD B LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD A SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING gL C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -HMC -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING I L I FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW TIEMENS 4S BOX W/ 1G RING CEILING n FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. Pc, FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX W/ 1-1 /2" EXT. 80" A.F.F. TO BOTTOM FIRE' ALARM STROBE (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JBOX FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD 0'I JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A,F,F ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O{ FURNISHED BY OTHERS N/A N/A N/A N/A N/Al NOT APPLICABLE N/A N/A N/A N/A U,❑,N UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP' WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A I( Copyright 2006 by Guardian PM) r.; 2 2008 Tukwila Fire Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS ro u DESCRIPTION uJ C aJ H 6ALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 4/07/08 BACKGROUND PLAN PROVIDED BY: 0 JOB NUMBER:54485 } % SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVI❑US ADDRESSABLE DEVIC o DUCT DETECTOR LOCATI❑N END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH m GROUND —'_CD 0 HTRI-R STATUS LED 00 m N.O. N. 0 COM (0 0 N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE r DEVICE + NOTE 11 VOLTAGE MAX. - CURRENT MAX,- C❑NT, RES. MAX. - MAX, CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX, LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE LI -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE So) STOP IF LAST DEVICE 11-) FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE (-) RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) 27 VDC 3,5 mA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0,02uF 0,04uF 14 AWG 18 AWG NOTE 21 • ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. 0 1 0 0 1 TB1 S (5 m a m m 123456 TB2 CP mm4ci\m� 654321 0 0 0 J END OF LINE DEVICE <3.6K 1/4W) 0 SUPERVISED SWITCH GRnI INTI 0 0 0 HTRI-D OSTATUS LED N m / NOT USED 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 'TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) O .,GNDN AC T T T H LI 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - m mm� 0 0 0 0 2,�4.4444m� 24K n TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE z NAC -4 NAC -3 2 NAC -2 NAC -1 END OF LINE DEVICE 3.6K 1/4W) UPERVISED SWITCH ( FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP.! 0 0 0T (FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS 4W EOL T M-1 0 s s lz:Ei3.4 :5- CC-.- Co TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL EARTH GROUND .. .(+)TO NEXT DEVICE OR -->(-) STOP.IF LAST DEVICE} FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) SCALE: NONE (+) (-) STROBE SPEAKER ( STROBE ( STROBE SPEAKER (+) (-) SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE - OR STROBE ONLY E • 0 4S DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE -' TO NEXT DEVICE OR -� END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERtTIN TEMPERA RE: +32' F (0' C) TO 100' F 3B C) HUMIDITY: 0-9$$$$$3% RELATIVE HUMIDITY, NON -CONDENSING HP -11 SMOKE DETECTOR 1 -> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE fDATA IN (-) >--- DATA IN (+) > I I REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICEF > ( ) DATA OUT 1 > (+) DATA OUT J7 CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING SPEAKER SUPPORT BRIDGE HARD LID 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTION BOX-, MOUNTED ON \ CEILING FLEX \ / / / JUNCTION BOX \ / MOUNTED A AINST / CEILING SUPPORT / 11 0 0 H Z25 I TO NEXT DEVICE 0 0 CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE=NONE --- SUSPENDED ILLUMINATED CEILING Copyright .2006 by Guardian Security Systems, Inc. All Rights Reserved a cit IW Z otit r,r) co ON O F-- C� z_ W F— F- W Cl) O W 1,0 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS z z 3 O 0 00 J _J W 2Z o 0 m�� O z z —. moW =CCo cn wI— o I Q M� F— F-- W a J 0 0. SCALE: 1 /8"= DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 4/07/08 BACKGROUND PLAN PROVIDED BY: \OB NUMBER:54485 J SHEET FA -02 l 1'. 7,4 011r001 Itob4TCf.. ---- LIEt3 Il:(1,i21, EOL—S1- 18.04V INWNTOFI"JAIF ROAM LEII.IIJI; M, 10' -0' AIT 4A0AGER UfF10E Ar,1--1 CE,UIJC 4 Ri-0';FF. '1 :6EN C13. CEWNG Ct 6'-0' AT. t� 1008,E P01210:0000 1D' --O' i:.. MEN H r,:ILINr; d h -ri 40 6311' S1GR1 14'1141 ----------- 204 00011;FC LIG:( ---- -._ S4:*11FE, DP. STOR4'1C AC' -2 OENNC n ;r. -D' ATr EQ. F-` e FA BOX 23,2V —o 3'-0 2i VT 11) r / .6) i R D D C 3C D r1 32 CG E1 ;TOP A4l 4011 MJ , DT. I. • I . q ii2 C SUrrT PP 6'-ri AFF, T+P -, s) 7 it 11 I! 1 I VLA I, . • 32 f EQ. A TAT \\/ /f uG;D cE11.3 132,03E :0 "E C +81:11:3 "°23,2V ❑ V 2 F FI (1f14Ckf •A! 0114 1 )'J Di;, 1 10 1.14106 1?i 1 j PLAN IC)CiJJS,-1 r'. % ! H / 1 • 1 !I l I' I II I i • ! wlN.OV+ FANNER, :1P. Il'.!� ,.< j 1 1 , • if/, F ((1�,...._-I-'-'-fI (FF.i:l1) i• Ii l lo j j I !I,Ii'• I! I ! ! fill/. i ()ITT -I ! i.9. CrIIIIIC 13 1S' ^.' AIF. 100 ! I ,,,.�---- ----- 3 Gi--. 1 -'. j 1 4EI. PE11IIJIi 41 10'- 0' Arr. 11?. i. Ii,;_. -r---- .all-_ i; P... I 1 rl-A C 2' 1.5 Q, 140011 0 L ROOM OPEN CEII;rlG 1'3 S131fC1'I@E -n .r i 6' -I -r A I,1*1I Q 1 !I. 7-5---- -------- co 4 6'-0' \\\` \ \ 111 p \ \ ,-;0442,R,'\l,-;0442,R, 306E4 .11 0016 POS., 017, \ \\ \ '— ;13'-'i' L:ir R: RADIUS 40 RA1CH �\ `\\ 11001 F:SI! rADIUi, 1`1,. \\ \ ACr-. 1.111,01, Q ?-A' 401, \�-- 5' 311:0 COMPASAC) CO;C 'RLN PRE,-Foml:3; rlF• x+--r:p-(13130 A 3 (TDP. .V V LC7) �LI? CPA; -6 15'--C' OFF. PfD. 0.E' CCL'%O Q 15'- 31' A -'r. lYl°. - ` -t +\+s :roIv :' IP •-C' VP, AP. „00030 AT 3'-C' /01', ,,,. ED 00RATRA11E: 330>: r(3.) 3:01.040 k Copyright. 2006 by Guardian Security Systems, Inc. All Rights Reserved z ca e szxz 1_ JJ W a'{ co z N o z ▪ CD - N LL W J H- I— W (/) O u) W F1,0 TEL. (206) 622-6545 RELEASE/REVISIONS co u.i ct I DESCRIPTION DATE 9_ CCa<a COCO J � J W Z O CO I.L W cn z 2CCUtn cn H SCALE: 1/8"=1' 0 0 J CC CC DRAWN BY: I.ANDERSON DESIGNED BY: R.VEZZANI DATE: 4/07/08 BACKGROUND PLAN PROVIDED BY: \ 0B NUMBER:54485 SHEET FA -03 I L .1 1.3 1000 11' NORTIA i"Icv,zr; II CI) 0 LI) F - 1.r.) fOILE1 I 1010 2(1 ----- - ! ; ------ 1560 [1550 IQ! 1545 LLEGTIcALII Room ;;! IC IC IC 15,1-0 TF -IE WALKING CO, 1 1001 KeYCLil!jC. `.;Tc.IRACE -; A M R A TIEC A ';v1EX IC IN IVLAC I LI CJALIFOFRNIA PIZZA KITCHFN 51 1 b ebe 1110 LOADING Co 7.) 1.1.1 Cr: <11: C3-77 11251 15151 1_1.1 P F CHANG' (23 P2 /.. AT&T WESTFIELD SOUTHCENTER MALL Ar SCALE 1132"4 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 0 0 0 0 7511 : 13 : 13 : :ii: 13 015 C 75 30 15 C 15 C 30 C D D c:5-11, I El TSM El mo EOL -S1 17.61V cp- 2S,2V FA -BOX 2S,2V • c- fl TACT EX PSI SYSTEM CALCULATIONS AT&T FACP ADD ONS I , Current Load:1!!i Standby: Alarm: • ;! I! I ; !,;, • ! Device Type.: -HFP-11 ' • Qty Amps Total Amps Total I ! , 2 0.0022 0.0022 0.0023 0.005 AD2-P HTR -R HTRI-D ICP -B6 • ; 2 0.0635 0.009600 0.0635 0.0096 0.064 0.021 0.042 0.001600 0.005 0.0731 0.0035 Amps 0.042 Amps t'-'1'1•!: • .1', • ," Standby CurrOnt Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours " 1 !' • ' • Alarm Current Load:, 0.042 Amps For 5 Minutes= 0.004 Amp -hours ,;;! : • tt , • I Total System Current Load: 25% Derating= 2.197 2.197 Amp -hours Amp -hours 1 ; Battery Pair to be Used: 12VDC Amp -hours 7AH I •.;!,! 1' AT&T SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations • .1: , i Notification Appliance Circuit MALL Detail 3.24 1293 ______________________ _ ..........._______ HI Current Load: Standby: Alarm: Wire Resistance _ Date: April 29, 2008 .CURRENT TOTAL= <<<<< CIRCUIT: Device Type Qty Amps Total Amps Total „ ,1 QTY Device Type _ Alarm Current Alarm Total , I r Main System Board 1 , ,' 0.03 0.03 0.030 0.030 QTY SET -MC @15CD 1 1.83 2 0.064 0.064 , I SET -MC @30CD 2 5 0.098 0.196 297 SET -MC @75CD 2 , ___ 0.175 0.350 1.29 SET -MC @110CD @110CD , o 0.233 SET-HMC-C@115CD (Total Cct Load) ( WL * 2 )* (R/ft) 0 0.048 318 : ! SET-HMC-C@135CD 1 ' _ 0.318 2.36 0 SET-HMC-C@185CD 4450 0.445 0 ZR -MC @15CD 2 0 SET -HMC @135CD 0.064 0.128 ,!1•I ZR -MC @30CD Voltage Drop ( E ) EOL Voltage 0.098 0 SET -HMC @185CD HCP 0 0.0015 H (E= I * R) 2 Z-MC@15CD 0.03 Amps 0.768 Amps 0 Z-MC@30CD 1•1! Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours 0 SET-MC-CW@11OCD , 264. 0 0 18.037223521_ 1293 Alarm Current Load: 0.768 Amps For 5 Minutes= 0.065 Amp -hours _1293 12 202 0 .1 , 25% Derating= 0.981 Amp -hours !,: 'Li 1 : DEVICES= 5 TOTAL mA= 9 _ 14 Total System Current Load: 0.981 Amp -hours . , Battery Pair to be Used: 12VDC. . Amp -hours 7AH BATTERY sizowGNcu_A-poN • CD 0' Sir co c\J 0 cp RELEASE/REVISIONS REV. BY: 1 Notification Appliance Circuit MALL Detail 3.24 1293 ______________________ _ ..........._______ PROJECT: WESTFIELD SOUTHCENTER Panel: AT&T Wire Resistance _ Date: April 29, 2008 .CURRENT TOTAL= <<<<< CIRCUIT: S1 Date:. ___ Wire LIf rength Voltage at EOL Circuit Total QTY Device Type _ Alarm Current Alarm Total Wire Size 1 SET -MC @15CD .117 117 QTY Device Type Total Wire Resistance ( R ) WL * 2 ) * (Rift) 1.83 2 SET -MC @30CD 180 360. ;( 5 2 SET -MC @75CD 297 594 , - I ___ Total Device Load, Amps (I) 1.29 0SET-MC . _ @110CD 233 o (Total Cct Load) ( WL * 2 )* (R/ft) 0 SET-HMC-C@115CD 318 0 _ 1 ' _ Voltage Drop ( E ) 2.36 0 SET-HMC-C@177CD 4450 0 0 0 (E= I * R) 0 SET -HMC @135CD 318 0 _ Voltage Drop ( E ) EOL Voltage 18.04 0 SET -HMC @185CD 445 0 (20.4 - E) (E= I * R) 2 Z-MC@15CD 111 222 0 0 Z-MC@30CD 200 o •I 0 SET-MC-CW@11OCD , 264. 0 0 18.037223521_ 1293 . DEVICES= 7 TOTAL mA= _1293 12 202 • CD 0' Sir co c\J 0 cp RELEASE/REVISIONS REV. BY: . Notification Appliance MALL Circuit Detail DESCRIPTION PROJECT: WESTFIELD SOUTHCENTER 5.16.' • ' ' . ' ' 9 Panel: AT&T 2 <<<<< Wire Resistance Date:. April 29, 2008 CURRENT TOTAL= CIRCUIT: SPEAKER CIRCUIT QTY Device Type Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 5 70.7V 1/8 1.8 9 , Total Wire Resistance (R)2.91 00 - 0 ( WL * 2 )* (R/ft) 0 _ 0 0 ;1- Total Device Load, Amps (I) (Total Cct Load) 0.01 0 0 0 0 0 1 Voltage Drop ( E ) 0.03 o 0 (E= I * R) 0 _ 0 0 EOL Voltage 20.37 00 (20.4 - E) 0 0 - - 0 0 , 20.373807841 DEVICES= 5 TOTAL mA= 9 _ 14 • CD 0' Sir co c\J 0 cp RELEASE/REVISIONS REV. BY: DESCRIPTION DATE 2 <<<<< SCALE: 1/8"=1' 1,!!•, NUMBER:54485 DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 4/07/08 BACKGROUND PLAN PROVIDED BY: RISER DIAGRAM • i!rl' t, • • • t VOLTAGE DROPICALCULATION Copyright 2006 by Guardian Security 'Systems, Inc. All Rights Reserved t .11.411,41, SHEET FA -04 344 SOUTHCENTER MALL ASSOCIATED PERMITS 16-F-162 08-F-148 08-S-100 tggni SITE LOCATION 2 L L\ Site Address:W Soutcenter Mall Suite Number: Floor: CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Tenant Name: At&T Mobile New Tenant? ❑ - Yes 0- No Property Owner's Name: Westfield Shopping Center Mailing Address: fag Southcenter Mall, Tukwila, WA 98188 Z:b0o City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 2.349.5889 Company Name: Guardian Security Mailing Address: 1743 First Ave S, Seattle, WA 98134 kveliz@guardiansecurity.com City State Zip E-mail Address: Fax Number: 206.374.2852 Contractor's City of Tukwila NICET III number: Business License number: GUARDSS233K5 Exp. 09/30/2016 Total number of new/relocated devices or sprinkler heads: 9 Valuation of Project (contractor's bid price): $ 3,600. Scope of Work (please provide detailed information): Fire Alarm System Alteration: Add 9 device. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING WNER OR AUT RIZED AGENT: Signature: C _ Date: Print Name: Karma Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 8/22/14 TFD FP Form 8 A ori FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: AT & T 344 Southcenter Mall Permit No.: 08-S-100 Date: March 31, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. 11 u)fcS"i Job Number KS0300 c.� a - Report Description: .'w„- _ -::;:p ;.> _ ,; - e , AT&T Zone Ti Job _: „ - ..-.. ., _ esr _rt,:,T�:. `i�{�„ �•x,?I"i.,,>',; ."tet- : .. ...,« :. `,SY:'� Fc: -_ + es-S;:a pp > , ,. .. ,:n- - :: Vii..' ^t:",i:"N:. sV- gr�`;x;`•'I _, a Job Number a_, - �a+ . -- ;>3: - `r KSO3OO _.. .....'.'�`� kt ,da: . . ..." . . Design Engineer Adam Kanter --r1ob-Name—__— ---_ --_—__ — AT&T Address 1 State Certification/License Number WESTESF136QF 344 Southcentner Mall Address 2 A City of Tukwila City Job Site South center Mall Tukwila State Wa Zip Code 98188 Drawing Name FP-1.cad S" stem:'.."r:,. :.-,. Ar Most Demanding Sprinkler Data , ...;r('$C",::•a,'J.5`_ r_"t:'r;'''t.'-' r 5.6 K -Factor 26.00 at 21.556 Hose Allowance At Source .is _ _ Occupancy '"•' • ^n -�.... . Ordinary Group II 250.00 Additional Hose Supplies Density 0.20gpm/ft2 Area of Application 1130.00ft2 (Actual 1130.39ft2) Node Flow(gpm) Number Of Sprinklers Calculated 14 Coverage Per Sprinkler 130.00ft2 roction 0°y2� et ,�t� CFrtq: Total Hose Streams 250.00 O , s'"' Oj„ ; �,,; h System Flow Demand Total Water Required (Including Hose Allowance) a, { ,h 399.88 649.88 'f;i i A. er`', Maximum Pressure Unbalance In Loopsil 0.000 .�: \L%d�'�y`'�i' Beat —T Maximum 26.80 between nodes 161 and 229 36l0r Maximum Velocity Under Ground 1.51 between nodes 1 and 417 Ss —,.-, Volume capecity of Wet Pipes 2453.38ga1 I Volume capacity of Dry Pipes 0.75ft3 Node 1 Hose Flow (gpm) Static (psi) Residual © Flow (psi) (gpm) Available @ Total Demand (psi) (gpm) Required (psi) Safety Margin 250.00 140.000 20.000 10900.00 139.349 � 649.88 92.711 6.63 46.638 *,t fir' - `:--'.H`'er icer ",'•tet-:;.�: ._a Contractor Name Contractor Number KSO300 Contact Name Adam Kantner ,._ .• ' - ntact Title ceProject Manager Western States Fire Protection Address 1 Phone 425.881.0100 Extension 7102 180th Ave Ne, Suite A-105 Address 2 FAX 485.736.9032 City E-mail Redmond State WA Zip Code 98052 Web -Site er Data Job Number:50300 K Report Description: AT&T Zone T1 ��.; S:ia;lrn .a ,. tfilOW 11 98 ti . ;�;��:: .........,, Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler _ _ 109 30.05 26.0D__ _- _ _ _ -5.6 - 28,798 Sprinkler 113 34.31 26.00 5.6 37.537 Sprinkler 110 30.32 26.00 5.6 29.309 Sprinkler 105 27.70 26.00 5.6 24.473 Sprinkler 106 28.54 26.00 5.6 25.978 Sprinkler 112 33.41 26.00 5.6 35.602 c Sprinkler 101 26.00 26.00 5.6 21.556 Sprinkler 104 27.65 26.00 5.6 24.386 Sprinkler 114 33.58 22.40 5.6 35.947 Sprinkler 102 25.07 24.00 5.6 20.040 Sprinkler 103 27.12 26.00 5.6 23.451 Sprinkler 107 24.09 20.00 5.6 18.502 Sprinkler 108 24.40 20.00 5.6 18.983 Sprinkler 111 27.64 20.00 5.6 24.363 er Data Job Number: KS0300 Node Elevation(Foot) Fittings Pressure(psi) INcpViL Discharge(gpm) LiCJtoltpuuII. /Alai cone 1 _1 127 14-2 P0(26-4) 78.805 161 15-3 ------ 32..087-- - 229 15-3 2P0(8-0) 53.182 230 15-3 2P0(8-0) 50.738 232 15-3 P0(8-0) 50.485 274 15-3 P0(5-0) 31.054 276 15-3 P0(5-0) 40.288 295 15-3 P0(5-0) 31.621 353 1-11 85.506 394 15-3 P0(5-0) 26.099 417 5-8 BFP(-4.500) 88.420 426 1-11 P0(37-8%) 85.428 436 15-3 P0(5-0) 27.776 469 15-3 P0(5-0) 38.235 486 15-3 P0(5-0) 22.952 489 15-3 P0(5-0) 26.001 495 15-3 E(2-0) 37.614 499 15-3 P0(5-0) 21.155 502 15-3 P0(5-0) 24.960 505 15-3 P0(5-0) 20.865 508 15-3 E(2-0) 20.850 511 15-3 E(2-0) 24.793 109 12-0 Spr(-28.798) 28.798 30.05 113 8-0 Spr(-37.537) 37.537 34.31 110 12-0 Spr(-29.309) 29.309 30.32 105 12-0 Spr(-24.473) 24.473 27.70 106 12-0 8-0 Spr(-25.978) Spr(-35.602) 25.978 35.602 28.54 33.41 112 101 12-0 Spr(-21.556) 21.556 26.00 104 12-0 Spr(-24.386) 24.386 27.65 114 8-0 Spr(-35.947) 35.947 33.58 102 12-0 Spr(-20.040) 20.040 25.07 103 12-0 Spr(-23.451) 23.451 27.12 107 15-0% Spr(-18.502) 18.502 24.09 108 15-0% Spr(-18.983) 18.983 24.40 111 15-0% Spr(-24.363) 24.363 27.64 1 -4-0 S 92.711 399.88 Pipe Type Diameter Downstream Elevation Upstream rrr • •-Route 1 DR 101 486 Flow Velocity HWC Friction Loss Discharge K -Factor Pt Pn Fittings Job Number: KS0300 Report Description: AT&T Zone T1 1.049 12-0 15-3 CM 1.610 486 15-3 394 15-3 Q=26.00 9.65 Length Eq. Length Total-Lengt Pressure Summary C=120 q=26.00 K=5.6 0=99.56 15.69 21.556 22.952 C=120 CM 1.610 394 15-3 274 15-3 Q=127.26 20.06 22.952 26.099 0.211435 Spr(-21.556) 2E(2-0), P0(5-0) 0.314656 C=120 CM 1.610 274 15-3 229 15-3 Q=157.31 24.79 26.099 31.054 0.495550 C=120 CM 2.469 229 15-3 161 15-3 Q=399.88 26.80 31.054 53.182 0.733529 P0(8-0) C=120 CM 4.260 161 15-3 127 14-2 Q=399.88 9.00 53.182 72.087 C=120 CM 6.357 127 14-2 426 1-11 Q=399.88 4.04 72.087 78.805 C=120 FM 8.329 426 1-11 353 1-11 MS 353 417 Q=399.88 2.35 78.805 85.428 C=120 10.020 1-11 5-8 Q=399.88 1.63 85.428 85.506 C=120 UG 10.400 417 5-8 1 -4-0 Gi Route 2 Q=399.88 1.51 85.506 88.420 C=140 88.420 0.513633 fT(10-9%) 0.036058 2P0(26-4), 2Ee1(5-3), fEE(3-5) 0.005133 4- Pf 2.798 9-t Pe -1.402 13- Pv 10-I Pf 3.147 Pe 10-r Pv 10-4 Pf 4.956 Pe 10-s Pv 22- Pf 22.128 8-i Pe 30-2 Pv 26-i Pf 18.905 10-9Y. Pe 36-9Y Pv 3fE(10-0), E(17-7), fT(25-0), CV(40-3), GV(3-9%), P0(37-8% 0.001377 2fE(16-0) 0.000560 106- 66-7 173-3 102-1 154-4 256-5 Pf 6.248 Pe 0.470 Pv Pf 1.316 Pe 5.307 Pv 3LtE(16-0), BV(19-0), BFP(-4.5 0.000351 00) 92.711 3LtE(25-6), E(35-1), 2EE(17-6%), S 24-8Y Pf 0.078 32- Pe 0.000 56-8Y Pv 20- 67- 87- Pf 4.549 Pe -1.635 Pv 113-1Pf 0.091 146- Pe 4.200 259-9'/ Pv DR 1.049 0=25.07 9.31 C=120 0.197642 102 12-0 q=25.07 K=5.6 20.040 Spr(-20.040) 499 15-3 21.155 2E(2-0), P0(5-0) CM 1.610 0=73.56 11.59 C=120 0.179745 499 15-3 486 15-3 Route 3 DR 103 502 CM 502 489 21.155 22.952 1.049 12-0 15-3 Q=27.12 10.07 3-9 9-0 12-9 10-0 10-0 Pf 2.517 Pe -1.402 Pv Pf 1.797 Pe Pv C=120 1.610 15-3 15-3 q=27.12 K=5.6 Q=54.76 8.63 23.451 0.228576 Spr(-23.451) 24.960 2E(2-0), P0(5-0) C=120 24.960 26.001 CM 1.610 Q=82.41 12.99 C=120 0.221825 489 15-3 26.001 436 15-3 27.776 CM 436 295 0.104128 1.610 15-3 15-3 0=110.96 17.49 C=120 0.384540 27.776 31.621 CM 1.610 0=141.27 22.26 C=120 0.601205 295 15-3 31.621 230 15-3 50.738 P0(8-0) CM 2.469 0=242.57 16.26 C=120 0.203719 230 15-3 50.738 229 15-3 53.182 m► Route 4 DR 1.049 0=27.65 10.27 C=120 0.236986 104 12-0 q=27.65 K=5.6 489 15-3 ®r Route 5 DR 105 394 Route 6 DR 106 436 1.049 12-0 15-3 Q=27.70 10.28 3-9 Pf 2.911 9-!1 Pe -1.402 12-9 Pv 10-0 Pf 1.041 Pe 10-0 Pv 8-0 Pf 1.775 Pe 8-0 Pv 10-0 Pf 3.845 Pe 10-0 Pv 23-9% Pf 19.116 8-0 Pe 31-9% Pv 12-0 Pf 2.445 Pe 12-0 Pv 24.386 Spr(-24.386) 26.001 2E(2-0), P0(5-0) 3-9 Pf 3.018 9-d Pe -1.402 12-9 Pv q=27.70 K=5.6 C=120 24.473 26.099 e� Route 7 0.237772 Spr(-24.473) 2E(2-0), P0(5-0) 1.049 0=28.54 10.60 C=120 0.251269 12-0 q=28.54 K=5.6 25.978 Spr(-25.978) 15-3 27.776 2E(2-0), P0(5-0) Pf 3.028 9- Pe -1.402 12- Pv 3-9 Pf 3.200 9-d Pe -1.402 12-9I Pv (� Hydrap lic�An;alysis Job Number KS0300 Report Description: AT&T Zone T1 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream -t04J Eq. Length Total_Length Summary DR Q=24.09 8.94 C=120 0.183572 _ 4-41/2 107 15-0% q=24.09 K=5.6 18.502 Spr(-18.502) 505 15-3 20.865 2E(2-0), P0(5-0) 9-0 13-4% Pf 2.458 Pe -0.096 Pv CM 1.610 0=48.49 7.64 C=120 0.083142 3-6 505 15-3 20.865 499 15-3 21.155 3-6 Pf 0.290 Pe 0.000 Pv Oa Route 8 DR 1.049 0=24.40 9.06 C=120 0.187983 4-5% 108 15-0% q=24.40 K=5.6 18.983 Spr(-18.983) 508 15-3 20.850 3E(2-0) 6-0 10-5% Pf 1.962 Pe -0.096 Pv CM 1.610 0=24.40 3.85 C=120 0.023337 0-7% 508 15-3 20.850 505 15-3 20.865 0-7% Pf 0.015 Pe Pv Route 9 DR 1.049 0=30.05 11.16 C=120 0.276402 4-3 9-0 13-3 Pf 3.658 Pe -1.402 Pv 109 12-0 q=30.05 K=5.6 28.798 Spr(-28.798) 274 15-3 31.054 2E(2-0), P0(5-0) Route 10 DR 1.049 0=30.32 11.25 C=120 0.280929 4-3 9-0 13-3 Pf 3.724 Pe -1.411 Pv 110 12-0 q=30.32 K=5.6 29.309 Spr(-29.309) 295 15-3 31.621 2E(2-0), P0(5-0) a Route 11 DR 1.049 0=27.64 10.26 C=120 0.236782 0-2% 2-0 2-2% Pf 0.526 Pe -0.096 Pv 111 15-0% q=27.64 K=5.6 24.363 Spr(-24.363) 511 15-3 24.793 E(2-0) CM 1.610 0=27.64 4.36 C=120 0.029396 5-8 5-8 Pf 0.167 Pe -0.000 Pv 511 15-3 24.793 502 15-3 24.960 a* Route 12 DR 1.049 0=33.41 12.40 C=120 0.336310 8-1% 9-0 17-11/2 Pf 5.764 Pe -3.130 Pv 112 8-0 q=33.41 K=5,6 35.602 Spr(-35.602) 469 15-3 38.235 2E(2-0), P0(5-0) CM 1.610 0=66.99 10.56 C=120 0.151189 13-7 13-7 Pf 2.052 Pe Pv 469 15-3 38.235 276 15-3 40.288 CM 1.610 Q=101.30 15.96 C=120 0.324923 23-4% 8-0 31-4% Pf 10.197 Pe Pv 276 15-3 40.288 232 15-3 50.485 P0(8-0) CM 2.469 0=101.30 6.79 C=120 0.040499 6-3 6-3 Pf 0.253 Pe Pv 232 15-3 50.485 230 15-3 50.738 as Route 13 DR 1.049 0=34.31 12.74 C=120 0.353185 7-81 Pf 5.881 9-0; Pe -3.130 16- Pv 113 6-0 q=34.31 K=5.6 37.537 Spr(-37.537) 276 15-3 40.288 2E(2-0), P0(5-0) a* Route 14 DR 1.049 0=33.58 12.46 C=120 0.339323 8-11/ 6- 14-11/ Pf 4.797 Pe -3.130 Pv 114 8-0 q=33.58 K=5.6 35.947 Spr(-35.947) 495 15-3 37.614 3E(2-0) CM 1.610 0=33.58 5.29 C=120 0.042126 14-9 14-9 Pf 0.621 Pe Pv 495 15-3 37.614 469 15-3 38.235 Equivalnt:Pipe Lengths-C(.Ualves anti Fittings (C=120,only},,::II CValue-Multiplier (Actual Inside Diameter 487 Value Of C 100 130 140 150 Schedule 40 Steel Pipe Inside Diameter ) = Factor Multiplying Factor 0,713 1.16 1.33 1.51 111 Hydraullc: Analysis Pipe Type Diameter Downstream Elevation Upstream Pipe: Type::Legend Flow Discharge Velocity HWC K -Factor Pt Friction Loss Pn Fittings Job Number: KS0300 Report Description: AT&T Zone T1 UnitS-Legen AO Arm -Over Diameter BL Branch Line Elevation CM Cross Main Flow DN Drain Discharge DR Drop Velocity DY Dynamic Pressure FM Feed Main Length FR Feed Riser Friction Loss MS Miscellaneous HWC OR Outrigger Pt RN Riser Nipple Pn SP Sprig Pf ST Stand Pipe Pe UG Underground Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe Length Pressure Eq, Length Summary Total Length— - : i tings Legend, ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22'/z Elbow f Flow Device FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 150 135 120 105 Static Pressure 140.000 Supply at Node 1 Job Number: KS0300 Report Description: AT&T Zone T1 -649.88 with hose streams 90 -99.88 @ 92.711 E 75 N N d 60 System demand curve 45 30 15 0 10900.00 @ 20.000 IIIL IIIIIIILL 11111/111 I1 11 L1 LJ 1 111111111 91002200 3300 4400 Hydraulic Graph Supply at Node 1 Static Pressure 11111111/ I l I I 1 I I I I 5500 6600 I I I 1 I I 1 1 7700 Water flow, gpm 111111111 8800 1 I I 1 I 1 I 1 1 9900 11000 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.349 @ 649.88 System Demand 399.88 @ 92.711 System Demand (Including Hose Allowance) 649.88 @ 92.711 Wr' E VICINITY MAP SCALE: NTS General Notes Suite# 344) 1. Western States Fire Protection to add new pendent heads new uptight heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system onl in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. ;;7 I; 7 i"w a 61 RISER DETAIL HYDRAULIC REFERENCE ONLY YS'+!+9 •tR at SCALE Without Comment S As Noted In Red Per The Attached Letier t i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is urie t to errors and omissions which do not authorize violations of adopted t atanaaros and ordinances. The rc oon_ibility for the t edequacy of design rests totally with the designer. Additions, deletions or revisions to those drawings atter !aiS date iIi :0'd tnis acceptance cn.w ii require a resubmittal of revised drawings for subsequent approval. sinal acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: `1-'.J CT) By: 4asantrls. I uKWILA FIRE DEPARTME ' . Please call: 575-440Z and give this job No. 02-S- i(0° :nd exact address for shute 1, it or restoration aporov*% NOTICE Weld stamps must be inspected before pipe is hung. a n =t paint piping pr r to hydrostatic test EXISTING 4" Ti MAIN le=I®r® 71 eIT1=I®®®ee• II= dINeIm U EXISTING 4" T1 MAIN rem ® e e® =Te= use= ems ® em It= ®®I= = Ie:e teeeT ®® START NEW MAIN HERE 5-1 X1/2 A`h inVn AT&T Remote Area: Retail # 344 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD II MAX. COVERAGE per HEAD 130 DENSITY .20 GPM / Ft' for 1130 SPRINKLER Reliable Model G4A Ft' Ft' ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION': STATIC 140 RESIDUAL 20 FLOW AT BASE OF RISER, SYSTEM REQUIRES: 402 GPM @ 85.8 10900 PSI PSI GPM PSI ' At time of Design 15'-0" CLG.=32% AREA REDUCTION Ci) �0� 1 3-5 "• Ordinary Group II.0.20gpm/ft2 for 1130.00ft2 FIRE SPRINKLER SYSTEM 1/8"=1'-0" TYPICAL FLEXABLE SPRINKLER CONNECTION FLEXHEAD PIPE NIPPLE SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS MOUNTING BRACKET REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE FIG. 909 SWIVEL SWAY BRACE FITTING OI 3/9' KWIK BOLT (2 114' EMBED LENGTH) FIG.1000 "FAST CLAMP' SWAY BRACE ATTACHMENT LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE FIG. 4A PIPE CLAMP FOR SWAY BRACE 3/9' KWIK BOLT (2 1W EMBED LENGTH) FIG. 909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT LATERAL BRANCHLINE RESTRAINT BRACE PIPE cittd) NON -THREADED BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III HILT, Kwik Bolt II Rod Coupling Cut Rod Lgth Rounded to Nearest Inch All Thread Rod 'FYI Swivel Ring Concrete Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE EARTHQU 446-11 * IBRACINI i. - 2008 SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL APPROVAL: City of Tukwila 4 -WAY EARTHQUAKE BRACE R5415 48 5.6 Pendent yin White 155°F Rel G4A Concealer 0 HYDRAULIC REFERENCE POINT R3625 1 5.6 Upright %i' Brass 155°F Rel F1 FR SSU CONT. NO.: KS0300 HANGER SYMBOL BRANCHLINE RESTRAINT Total = 49 DRAWN BY: Adam Kantner SPRK. ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 04/01/08 Western States Fire Protection Company 7102 180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF138QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS/DECATUR/DENVER/DULUTH/HOUSTON/KANSAS CITY LOS VEGAS/MINNEAPOLIS/PHOENIX/PORTLAND/ RAPID CITY/SLPAUL/SALT LAKE CITY/SEATTLE Phone:425-881-0100 Fax:425-881-3030 Tukwila Fire a CB Bovenkamp, ARCHITECT: Adam Kantner w w z C7 Z w CB Bovenkamp, Inc CONTRACTOR: ,775 C/ yrs%.54 - AT&T 344 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SHEE FP OF 1 T 1 ILE -- D A F rAR K S D TE SH T ECTOR ADE. an Y� „IITIDDITIONON SHEET NUIV3ESHEET TITLE FA -01 SYSTEV INFHMATIO\ FA -02 TYPICAL WRING A\3 VI O U \ TI \G DETAILS FA -03 FRE ALAv SYSTEfv P _A\ TUKWILA FIRE DEPARTMENT se3s (.n3205-5754-407 205-57�f-� 5- � 't0Z and give W.0 1 1: x ^ Fre Permit t o enc' shut- down [ �'�C°1�,pproval. SHEET INDEX Without Comments ❑ As Notea in Re -4 ® Per The Attached Letter These plans have. Been reviewed by The Tukwila Fire Prevention Bureau -or conformance w -i fl current City standards. Accu:•)^ce is subject to errors and omissions whici; r.7> nor authorize violations of adopted standards anu c1f.!Ts-inces. The responsibility for the adequacy of des.. {sats totally with the designer. Additions, deinc, revisions to these drawings after this date wilt ti_,c,;c, , i.,:: .ceptance and will require a resubmittal r` r z!v e(t drawings for subsequent approval. Final acceptance 1E. subject to field test and Inspection by The Tukwila Fire ,'i eventior: Bureau. Date: 8.-10 -oto 8v: .5-1) WIRE SC NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must he presented to the ; nsf)cctor ^rior to commenceme: « cr Acceptance Testing of any Fire Marin and Detection Systems, Failure of test will result in a Re -inspection Fee and termination of the ting DULE AND CO\DUIT FILL CHAT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JJRISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX 3 3 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER E POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP. DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM EX--) E STROBE (EXISTING) EX ZR -MC -CW SIEMENS EXISTING CEILING 8E FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND R NORDSTROM 3 LEVELS ;1.275sf �3 Ui(Y' :•a53-sCT e1 macy. 4 LEv=LS _".4C7sf Y iC'UP.E srPlE. . • AT&T MOBILE #633 • « .00T Cf „acs s acnesa I - RE;Tuaon Y -s.- C RET+t Rn y 4 .: tet - -.• 55 a- Lf_ • 0. PAM SITE PLAN RTA � . I, , I -- JCPenney cx _AHs pp lD AtlG -a 2416 TUK\NI� A FIRE .44 cc z 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 08/04/16 2aaaaa z O 0 c O _ co W o2z I- <c f - w I- t� zz Lux � j 1 O C/) 1- TOC. cc 1z) W CC7 CO Z H (1) �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/04/1 6 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 17305-1) A _ P�iD Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved FA -01 SHEET THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDI11ONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ DEDICATED EMERGENCY l TUBE OUTLET--\ SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE: FOR ADDmcNAI. SPECIRCATIONS SEE PRODUCT DOGAIENTAI14N. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC Iff i1E All S D nit 1) TO NEXT ADDRESSABLE (+ DEVICE STIPIF LAST DEVICE FROM XLS CONTROL PANEL (4 OR PREVIOUS ADDRESSABLE DEVICE O 0 r u m '1 HTRI—R 0 0 O O NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C—CABLE C—CABLE GRD N L UY PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1— 1 2+ 2— 2 NC C NO + — + — + — + — + 0 0 0 0 a 0 Qpm 3.6k EOL (-) (+) NAC 4 CIRCUIT NAC 3 CIRCUIT NAC 2 CIRCUIT CEILIN TILE SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4° SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (-) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE -(+ FROM XLS CONTROL PANEL OR i+ PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH -- 0 (+) 1 GROUND 0 0 0 0 HTRI—R STATUS LED 0 N.0 0 COM c N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 MUSIC rTh HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY 0 HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL LAC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING RELAY CONTACTS (4,0A @ 125VAC) (4,OA @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERATING TEMPERATURE; +32'F (0' C) TO 100' F 38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON—CONDENSING HFP-11 SMOKE DETECTOR —, —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (—) > DATA IN (+) > TO NEXT DEVICE OR END OF LINE DEVICE IS USED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR ,— DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL > TO NEXT ADDRESSABLE DEVICE TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE e TB1 0®0®Q 10 NO COM NC J EOLR •vvV 470 0 00 TO FAN SHUTDOWN TO NEXT e ADDRESSABLE DEVICE 0 0 io NO IS COM e HTRI-R NC ® 0 O TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTION BOX— MOUNTED ON \ CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT J O O O 0 TO NEXT DEVICE CADDY BAR E]I SMOKE DETECTOR------- \\— SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved • CC o zt V) CO 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: SWITCH + — INPUT LED TSM -1 0 00 TO FAN SHUTDOWN TO NEXT e ADDRESSABLE DEVICE 0 0 io NO IS COM e HTRI-R NC ® 0 O TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTION BOX— MOUNTED ON \ CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT J O O O 0 TO NEXT DEVICE CADDY BAR E]I SMOKE DETECTOR------- \\— SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved • CC o zt V) CO 0' 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE tO O oo 0 z aaaaa z O 0 0 Qz co O0 EE Jr D 2z LAJ < H. W 0r W w 2: 17: 0 I-- CD DIL) U Dococi� 1 Li, `Cit ) W ,� MJ Cl) CC O I- x A W E-- 41C Fz O 0 Z C� Z J U �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/04/16 BACKROUND PLAN PROVIDED BY: �OB NUMBER:17305-12 r SHEET FA -02 SE SE HT -R TSM D 9 cp—D c= _ FIRE ALARM SYSTEM PLAN FLAG NOTES: DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. EXISTING BACK -OF -THE -HOUSE TENANT JUNCTION BOX. IZsa CC W ti • V) co ON 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 3 n DESCRIPTION SHOP DRAWINGS DATE 08/04/16 z 0 0 0 00 co _;(7,- W o 26 <11.1w 0 W�-- zz (/) U t= a U cc_1-1 � � dog d I W M J E-6 0 06 rSCALE: 3/16"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 08/04/ 1 6 BACKROUND PLAN PROVIDED BY: \ 0B NUMBER:17305-1} ( SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved \ J ( I i^ FILE COPY Y TEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \UM3ESHEET TITLE FA -01 SYSTEIv \FONATIO\ FA -02 TYPICAL DETAILS - WRI\G A\D y \TI \ G FA -03 FRE ALARM FLOC) PLA\ FA -04 VALL SITE PLA\ A\ D CALC U LATI O \ S M ❑ ACC Without Comments As Noted In Red Per The Attached Letter owe -;•isusentommisatenvay '1 'I? i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for cor,iorrn_nce with current city I standards. Acceptance is t.ubisot to errors and • omissions vrh c h1 do not auihoci2se violations of adopted s';an0C-.ir0s rind c:::: ,:. ,c .... i o: isib i ty for the • designer. drawings atter will require a .isubfnif L,! for subsequent approval. }nal acceptance i•; :i! 1!')JP,('i to held test and inspection by T n• Tukwila Firs PrOvon'Lion Bureau. •Date: 1-1--)N 9 By: TUKWILA FIRE DEPARTMENT. Please call; 575-440Z and give this job No.0 -F") and exact address for shut, bt'wn or restoration approval Because of increased demand our nspecors' schedules are booked 3-7 days ahead. Therefore, you will need to cafl 206-575-4407 or email Firesnsprealuest@cLt(*wila.yva.us to schedule your inspections tions a minimum of 43 hours in advance of the date you want an inspection. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE A ND CONDUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS • SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2V STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET), A ANNUNCIAT❑R TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART No. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT,SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-12" .82 SQUARE INCH 2' 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO • DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE O\1 ADDRESSABLE LOOP 1 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY' SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED, NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NEPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY,:., TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE, SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY• GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COvPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. . 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH ' A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NEPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 2 2 6 2 SYMB L DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS! REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D, DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZMI REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD B LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD A SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING gL C FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -HMC -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING I L I FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW TIEMENS 4S BOX W/ 1G RING CEILING n FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. Pc, FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. CEILING FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX W/ 1-1 /2" EXT. 80" A.F.F. TO BOTTOM FIRE' ALARM STROBE (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX 1/2" PIPE VERIFY IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JBOX FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD 0'I JUNCTI❑N BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A,F,F ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O{ FURNISHED BY OTHERS N/A N/A N/A N/A N/Al NOT APPLICABLE N/A N/A N/A N/A U,❑,N UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP' WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A I( Copyright 2006 by Guardian PM) r.; 2 2008 Tukwila Fire Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS ro u DESCRIPTION uJ C aJ H 6ALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 4/07/08 BACKGROUND PLAN PROVIDED BY: 0 JOB NUMBER:54485 } % SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVI❑US ADDRESSABLE DEVIC o DUCT DETECTOR LOCATI❑N END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH m GROUND —'_CD 0 HTRI-R STATUS LED 00 m N.O. N. 0 COM (0 0 N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE r DEVICE + NOTE 11 VOLTAGE MAX. - CURRENT MAX,- C❑NT, RES. MAX. - MAX, CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX, LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE LI -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE So) STOP IF LAST DEVICE 11-) FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE (-) RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) 27 VDC 3,5 mA DURING POLLING 10 OHMS 200 FT. (18 AWG) 0,02uF 0,04uF 14 AWG 18 AWG NOTE 21 • ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. 0 1 0 0 1 TB1 S (5 m a m m 123456 TB2 CP mm4ci\m� 654321 0 0 0 J END OF LINE DEVICE <3.6K 1/4W) 0 SUPERVISED SWITCH GRnI INTI 0 0 0 HTRI-D OSTATUS LED N m / NOT USED 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 'TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) O .,GNDN AC T T T H LI 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - m mm� 0 0 0 0 2,�4.4444m� 24K n TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE z NAC -4 NAC -3 2 NAC -2 NAC -1 END OF LINE DEVICE 3.6K 1/4W) UPERVISED SWITCH ( FRONT VIEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP.! 0 0 0T (FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS 4W EOL T M-1 0 s s lz:Ei3.4 :5- CC-.- Co TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL EARTH GROUND .. .(+)TO NEXT DEVICE OR -->(-) STOP.IF LAST DEVICE} FROM REMOTE POWER SUPPLY ('S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) SCALE: NONE (+) (-) STROBE SPEAKER ( STROBE ( STROBE SPEAKER (+) (-) SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE - OR STROBE ONLY E • 0 4S DEEP BOX W/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE -' TO NEXT DEVICE OR -� END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPERtTIN TEMPERA RE: +32' F (0' C) TO 100' F 3B C) HUMIDITY: 0-9$$$$$3% RELATIVE HUMIDITY, NON -CONDENSING HP -11 SMOKE DETECTOR 1 -> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE fDATA IN (-) >--- DATA IN (+) > I I REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE TO NEXT DEVICEF > ( ) DATA OUT 1 > (+) DATA OUT J7 CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID CEILING SPEAKER SUPPORT BRIDGE HARD LID 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTION BOX-, MOUNTED ON \ CEILING FLEX \ / / / JUNCTION BOX \ / MOUNTED A AINST / CEILING SUPPORT / 11 0 0 H Z25 I TO NEXT DEVICE 0 0 CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE=NONE --- SUSPENDED ILLUMINATED CEILING Copyright .2006 by Guardian Security Systems, Inc. All Rights Reserved a cit IW Z otit r,r) co ON O F-- C� z_ W F— F- W Cl) O W 1,0 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS z z 3 O 0 00 J _J W 2Z o 0 m�� O z z —. moW =CCo cn wI— o I Q M� F— F-- W a J 0 0. SCALE: 1 /8"= DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 4/07/08 BACKGROUND PLAN PROVIDED BY: \OB NUMBER:54485 J SHEET FA -02 l 1'. 7,4 011r001 Itob4TCf.. ---- LIEt3 Il:(1,i21, EOL—S1- 18.04V INWNTOFI"JAIF ROAM LEII.IIJI; M, 10' -0' AIT 4A0AGER UfF10E Ar,1--1 CE,UIJC 4 Ri-0';FF. '1 :6EN C13. CEWNG Ct 6'-0' AT. t� 1008,E P01210:0000 1D' --O' i:.. MEN H r,:ILINr; d h -ri 40 6311' S1GR1 14'1141 ----------- 204 00011;FC LIG:( ---- -._ S4:*11FE, DP. STOR4'1C AC' -2 OENNC n ;r. -D' ATr EQ. F-` e FA BOX 23,2V —o 3'-0 2i VT 11) r / .6) i R D D C 3C D r1 32 CG E1 ;TOP A4l 4011 MJ , DT. I. • I . q ii2 C SUrrT PP 6'-ri AFF, T+P -, s) 7 it 11 I! 1 I VLA I, . • 32 f EQ. A TAT \\/ /f uG;D cE11.3 132,03E :0 "E C +81:11:3 "°23,2V ❑ V 2 F FI (1f14Ckf •A! 0114 1 )'J Di;, 1 10 1.14106 1?i 1 j PLAN IC)CiJJS,-1 r'. % ! H / 1 • 1 !I l I' I II I i • ! wlN.OV+ FANNER, :1P. Il'.!� ,.< j 1 1 , • if/, F ((1�,...._-I-'-'-fI (FF.i:l1) i• Ii l lo j j I !I,Ii'• I! I ! ! fill/. i ()ITT -I ! i.9. CrIIIIIC 13 1S' ^.' AIF. 100 ! I ,,,.�---- ----- 3 Gi--. 1 -'. j 1 4EI. PE11IIJIi 41 10'- 0' Arr. 11?. i. Ii,;_. -r---- .all-_ i; P... I 1 rl-A C 2' 1.5 Q, 140011 0 L ROOM OPEN CEII;rlG 1'3 S131fC1'I@E -n .r i 6' -I -r A I,1*1I Q 1 !I. 7-5---- -------- co 4 6'-0' \\\` \ \ 111 p \ \ ,-;0442,R,'\l,-;0442,R, 306E4 .11 0016 POS., 017, \ \\ \ '— ;13'-'i' L:ir R: RADIUS 40 RA1CH �\ `\\ 11001 F:SI! rADIUi, 1`1,. \\ \ ACr-. 1.111,01, Q ?-A' 401, \�-- 5' 311:0 COMPASAC) CO;C 'RLN PRE,-Foml:3; rlF• x+--r:p-(13130 A 3 (TDP. .V V LC7) �LI? CPA; -6 15'--C' OFF. PfD. 0.E' CCL'%O Q 15'- 31' A -'r. lYl°. - ` -t +\+s :roIv :' IP •-C' VP, AP. „00030 AT 3'-C' /01', ,,,. ED 00RATRA11E: 330>: r(3.) 3:01.040 k Copyright. 2006 by Guardian Security Systems, Inc. All Rights Reserved z ca e szxz 1_ JJ W a'{ co z N o z ▪ CD - N LL W J H- I— W (/) O u) W F1,0 TEL. (206) 622-6545 RELEASE/REVISIONS co u.i ct I DESCRIPTION DATE 9_ CCa<a COCO J � J W Z O CO I.L W cn z 2CCUtn cn H SCALE: 1/8"=1' 0 0 J CC CC DRAWN BY: I.ANDERSON DESIGNED BY: R.VEZZANI DATE: 4/07/08 BACKGROUND PLAN PROVIDED BY: \ 0B NUMBER:54485 SHEET FA -03 I L .1 1.3 1000 11' NORTIA i"Icv,zr; II CI) 0 LI) F - 1.r.) fOILE1 I 1010 2(1 ----- - ! ; ------ 1560 [1550 IQ! 1545 LLEGTIcALII Room ;;! IC IC IC 15,1-0 TF -IE WALKING CO, 1 1001 KeYCLil!jC. `.;Tc.IRACE -; A M R A TIEC A ';v1EX IC IN IVLAC I LI CJALIFOFRNIA PIZZA KITCHFN 51 1 b ebe 1110 LOADING Co 7.) 1.1.1 Cr: <11: C3-77 11251 15151 1_1.1 P F CHANG' (23 P2 /.. AT&T WESTFIELD SOUTHCENTER MALL Ar SCALE 1132"4 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 0 0 0 0 7511 : 13 : 13 : :ii: 13 015 C 75 30 15 C 15 C 30 C D D c:5-11, I El TSM El mo EOL -S1 17.61V cp- 2S,2V FA -BOX 2S,2V • c- fl TACT EX PSI SYSTEM CALCULATIONS AT&T FACP ADD ONS I , Current Load:1!!i Standby: Alarm: • ;! I! I ; !,;, • ! Device Type.: -HFP-11 ' • Qty Amps Total Amps Total I ! , 2 0.0022 0.0022 0.0023 0.005 AD2-P HTR -R HTRI-D ICP -B6 • ; 2 0.0635 0.009600 0.0635 0.0096 0.064 0.021 0.042 0.001600 0.005 0.0731 0.0035 Amps 0.042 Amps t'-'1'1•!: • .1', • ," Standby CurrOnt Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours " 1 !' • ' • Alarm Current Load:, 0.042 Amps For 5 Minutes= 0.004 Amp -hours ,;;! : • tt , • I Total System Current Load: 25% Derating= 2.197 2.197 Amp -hours Amp -hours 1 ; Battery Pair to be Used: 12VDC Amp -hours 7AH I •.;!,! 1' AT&T SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations • .1: , i Notification Appliance Circuit MALL Detail 3.24 1293 ______________________ _ ..........._______ HI Current Load: Standby: Alarm: Wire Resistance _ Date: April 29, 2008 .CURRENT TOTAL= <<<<< CIRCUIT: Device Type Qty Amps Total Amps Total „ ,1 QTY Device Type _ Alarm Current Alarm Total , I r Main System Board 1 , ,' 0.03 0.03 0.030 0.030 QTY SET -MC @15CD 1 1.83 2 0.064 0.064 , I SET -MC @30CD 2 5 0.098 0.196 297 SET -MC @75CD 2 , ___ 0.175 0.350 1.29 SET -MC @110CD @110CD , o 0.233 SET-HMC-C@115CD (Total Cct Load) ( WL * 2 )* (R/ft) 0 0.048 318 : ! SET-HMC-C@135CD 1 ' _ 0.318 2.36 0 SET-HMC-C@185CD 4450 0.445 0 ZR -MC @15CD 2 0 SET -HMC @135CD 0.064 0.128 ,!1•I ZR -MC @30CD Voltage Drop ( E ) EOL Voltage 0.098 0 SET -HMC @185CD HCP 0 0.0015 H (E= I * R) 2 Z-MC@15CD 0.03 Amps 0.768 Amps 0 Z-MC@30CD 1•1! Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours 0 SET-MC-CW@11OCD , 264. 0 0 18.037223521_ 1293 Alarm Current Load: 0.768 Amps For 5 Minutes= 0.065 Amp -hours _1293 12 202 0 .1 , 25% Derating= 0.981 Amp -hours !,: 'Li 1 : DEVICES= 5 TOTAL mA= 9 _ 14 Total System Current Load: 0.981 Amp -hours . , Battery Pair to be Used: 12VDC. . Amp -hours 7AH BATTERY sizowGNcu_A-poN • CD 0' Sir co c\J 0 cp RELEASE/REVISIONS REV. BY: 1 Notification Appliance Circuit MALL Detail 3.24 1293 ______________________ _ ..........._______ PROJECT: WESTFIELD SOUTHCENTER Panel: AT&T Wire Resistance _ Date: April 29, 2008 .CURRENT TOTAL= <<<<< CIRCUIT: S1 Date:. ___ Wire LIf rength Voltage at EOL Circuit Total QTY Device Type _ Alarm Current Alarm Total Wire Size 1 SET -MC @15CD .117 117 QTY Device Type Total Wire Resistance ( R ) WL * 2 ) * (Rift) 1.83 2 SET -MC @30CD 180 360. ;( 5 2 SET -MC @75CD 297 594 , - I ___ Total Device Load, Amps (I) 1.29 0SET-MC . _ @110CD 233 o (Total Cct Load) ( WL * 2 )* (R/ft) 0 SET-HMC-C@115CD 318 0 _ 1 ' _ Voltage Drop ( E ) 2.36 0 SET-HMC-C@177CD 4450 0 0 0 (E= I * R) 0 SET -HMC @135CD 318 0 _ Voltage Drop ( E ) EOL Voltage 18.04 0 SET -HMC @185CD 445 0 (20.4 - E) (E= I * R) 2 Z-MC@15CD 111 222 0 0 Z-MC@30CD 200 o •I 0 SET-MC-CW@11OCD , 264. 0 0 18.037223521_ 1293 . DEVICES= 7 TOTAL mA= _1293 12 202 • CD 0' Sir co c\J 0 cp RELEASE/REVISIONS REV. BY: . Notification Appliance MALL Circuit Detail DESCRIPTION PROJECT: WESTFIELD SOUTHCENTER 5.16.' • ' ' . ' ' 9 Panel: AT&T 2 <<<<< Wire Resistance Date:. April 29, 2008 CURRENT TOTAL= CIRCUIT: SPEAKER CIRCUIT QTY Device Type Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 5 70.7V 1/8 1.8 9 , Total Wire Resistance (R)2.91 00 - 0 ( WL * 2 )* (R/ft) 0 _ 0 0 ;1- Total Device Load, Amps (I) (Total Cct Load) 0.01 0 0 0 0 0 1 Voltage Drop ( E ) 0.03 o 0 (E= I * R) 0 _ 0 0 EOL Voltage 20.37 00 (20.4 - E) 0 0 - - 0 0 , 20.373807841 DEVICES= 5 TOTAL mA= 9 _ 14 • CD 0' Sir co c\J 0 cp RELEASE/REVISIONS REV. BY: DESCRIPTION DATE 2 <<<<< SCALE: 1/8"=1' 1,!!•, NUMBER:54485 DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 4/07/08 BACKGROUND PLAN PROVIDED BY: RISER DIAGRAM • i!rl' t, • • • t VOLTAGE DROPICALCULATION Copyright 2006 by Guardian Security 'Systems, Inc. All Rights Reserved t .11.411,41, SHEET FA -04