Loading...
HomeMy WebLinkAboutPP - 426 SOUTHCENTER MALL - ZOUNDS HEARING - PERMITS AND PLANS426 SOUTHCENTER MALL ASSOCIATED PERMITS 18-F-080 08-F-203 18-S-058 08-S-166 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: ek-a Q • t A, 1( kDJ\ Suite Number: IiOW Floor: Tenant Name: CA T.AVC1 KVAil C New Tenant? ❑ - Yes * No Property Owner's Name:\ Q e),C\ TACc4eXt i ' Mailing Address v Wk ` D t D )0kC `_)XXJI RAO City State Zip CONTACT PERSON -if there are questions about the submittal. Name Q ! Company Name: l�lua-cv DLf\ 1 asJ'F-C.I►(yD Day Telephone:42a.Q- (,P `� 9`4t p Mailing Address: VI \* -ANtQ, • ` r E-mail Address:lT City State Zip �C 1� Y�1JC� CRCC 1 c c' rn [ . C.Ut`c1 Fax Number: �ntractor's City of Tukwi NICET III number: Business License number: — rite( 5+ Total number of new/relocated devices or sprinkler heads: 3 Valuation of Project (contractor's bid price): $ • W Scope of Work (please provide detailed information): Q, cOlocitm X\Cl J11\k- CVoN12x`y,[moi ccL5 PERMIT APPLICATION NOTES Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: W.(fll`� Date: t I 6 U ,( Print Name-eb•W Day Telephone: ?CU-- Plan C fj-- Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 1A h'1a11 Suite Number: i Mr) Floor. Tenant Name: O ra aQ n (✓ �,\` �' New Tenant? ❑ - Yes ❑ - No Property Owner's Name: \V44 Yp 1 Y l/1-� r Mailing Address: 2)0 SQ >+h Ma.)' /C, t}))'" City Sty Ap CONTACT PERSON -if there are questions about the submittal. Name: C'r \ GJ 1 1'l✓ 06316%44. Company Name: Mailing Address: E-mail Address: Day Telephone: 1.4 2 L-1 •76 (09 Ciro 1,0'1 'F-re,T tot e,.. -Ax or) 1 nc_ J JP City State Fax Number. Contractor's City of Tukwila NICET III number: 6t?(po • E5a i Cc, Business License number. 2,\.)5. D1 9 5$')Z Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): Sll V t0 Scope of work (please provide detailed information N6A_ � .�1� cS�� 1 n r h'C PERMIT APPLICATION NOTES Value of Construction — hi all cases, a value of construction amount should be eote<ed by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the watt authorized on the site by midi permit is wed or abandoned for a period of 180 days after the time the work is commenced The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 OR AU ZED AGENT: Signature: 1?/W°- Print C° -Print Name: VkScirA Ar7so7) Plan Permit App.doc 8/22/14 Date:. •ZI ` t Day Telephone: 112.5-'yv%710(21 TFD FP Form 8 • FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Zounds 426 Southcenter Mall Permit No.: 08-S-166 Date: May 5, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • .• • • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. Job Number: KS0354 Report Description: Ordinary Group II Job Number KS0354 Design Engineer Adam Kanter Job Name Zounds Hearing State Certification/License Number WESTESF136QF Address 1 426 Southcentner Mall City of Tukwila Address 2 Job Site Southcenter Mall City Tukwila State Wa Zip Code 98188 Drawing Name FP-1.cad Ref Most Demanding Spnnlder Data 5.6 K -Factor 20.00 at 12.755 Occupancy Ordinary Group II Hose AJlowence At Source 250.00 Density 0.20gpm/ft2 kea of Application 948.00ft2 (Actual 948.46ft2) Addigonal Hose Supplies Node Flow(gpm) Number Of SprinIders Calculated 13 Coverage Per SminIder 1 00.00ft2 Total Hose Streams 250.00 System Flow Demand 339.21 Total Water Required (Including Hose Allowance) 589.21 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 36.27 between nodes 137 and 32 Maximum Velocky Under Ground 1.28 between nodes 1 and 312 Volume capacity of Wet Pipes 2041.27gal Volume alpaca,/ of Dry Pipes 0.75ft' Node 1 Hose Flow (gpm) 250.00 Static (psi) Residual @ Flow (psi) (gpm) Available Total Demand (psi) (gpm) 140.000 20.000 1 10900.00 139.41 589.21 Required (psi) Safety Margin (psi) 93.264 46.193 Contraclar ......... Contrector Number KS0354 Contact Name Adam Kantner Contact Title Project Manager Contactor Name Western States Fire Protection Phone 425.881.0100 Extension Address 1 7102 180th Ave Ne, Suite A-105 FAX 485.736.9032 Address 2 City Redmond State WA Zip Code 98052 Web -Site M E P . CA D, Inc. AutoSPRINKO VR5 v5.2.6 04/29/2008 11:27:06AM Page 1 Job Number: KS0354 Report Description. Ordinary Group II Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) Sprinkler 105 22.03 20.00 5.6 15.482 i 411 Job Number: KS0354 Report Description: Ordinary Group II Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 12 14-6 E(2-0) 17.865 14 14-6 T(5-0) 15.241 15 14-6 PO(5-0) 17.919. 16 14-6 PO(5-0) 53.349 18 14-6 PO(5-0) 18.273 33 14-6 PO(5-0) 19.300 21 14-6 PO(5-0) 19.939 22 14-6 PO(5-0) 53.871 25 14-6 PO(5-0) 22.542 26 14-6 PO(5-0) 22.891 29 14-6 PO(5-0) 26.963 30 14-6 PO(5-0) 55.748 32 14-6 PO(5-0) 35.563 137 14-6 2P0(8-0) 63.742 138 14-6 2P0(8-0) 63.890 272 1-11 T(50-0) 86.096 282 1-11 P0(26-4) 86.041 312 5-8 BFP(-4.500) 88.997 105 16-5% Spr(-15.482) 15.482 22.03 101 8-6 Spr(-12.755) 12.755 20.00 102 8-6 Spr(-13.248) 13.248 20.38 111 8-6 Spr(-41.389) 41.389 36.03 103 10-0 Spr(-14.600) 14.600 21.40 106 7-6%2 Spr(-16.117) 16.117 22.48 104 11-6 Spr(-14.912) 14.912 21.63 112 8-6 Spr(-41.783) 41.783 36.20 107 9-0 Spr(-17.942) 17.942 23.72 108 10-0 Spr(-18.015) 18.015 23.77 109 8-6 Spr(-20.613) 20.613 1 25.42 113 8-6 Spr(-43.203) 43.203 36.81 110 10-0 Spr(-27.444) 27.444 29.34 1 -4-0 S 93.264 339.21 , © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11: 27:08A M Page 3 Job Number: KS0354 Report Description: Ordinary Group 11 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Eq. Length Total Length Pressure Summary Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings aaw Route 1 DR 1.049 0=20.00 7.42 C=120 0.130131 36-11% Pf 5.070 101 8-6 q=20.00 K=5.6 12.755 Spr(-12.755) 2-0 Pe -2.585 14 14-6 15.241 E(2-0) 38-11% Pv AO 1.049 Q=40.38 14.99 C=120 0.477463 0-7'/2 Pf 2.678 14 14-6 15.241 5-0 Pe 15 14-6 17.919 P0(5-0) 5-7/2 Pv BL 1.610 0=62.42 9.84 C=120 0.132656 2-8 Pf 0.354 15 14-6 17.919 Pe 18 14-6 18.273 2-8 Pv BL 1.610 0=83.81 13.21 C=120 0.228851 4-6 Pf 1.027 18 14-6 18.273 Pe 33 14-6 19.300 4-6 Pv BL 1.610 0=106.30 16.75 C=120 0.355197 1-91'2 Pf 0.638 33 14-6 19.300 Pe 21 14-6 19.939 1-9/z Pv BL 1.610 Q=127.92 20.16 C=120 0.500330 5-2/2 Pf 2.603 21 14-6 19.939 Pe 25 14-6 22.542 5-2/: Pv BL 1.610 Q=151.64 23.90 C=120 0.685374 0-6 Pf 0.349 25 146 22.542 Pe 26 146 22.891 0-6 Pv BL 1.610 0=175.41 27.64 C=120 0.897253 4-6% Pf 4.072 26 14-6 22.891 Pe 29 14-6 26.963 4-6% Pv BL 1.610 Q=200.84 31.65 C=120 1.152565 7-5/z Pf 8.600 29 14-6 26.963 Pe 32 14-6 35.563 7-5/: Pv BL 1.610 0=230.17 36.27 C=120 1.483233 11-0 Pf 28.178 32 14-6 35.563 8-0 Pe 0.000 137 14-6 63.742 P0(8-0) 19-0 Pv CM 4.260 0=230.17 5.18 C=120 0.012979 11-5 Pf 0.148 137 14-6 63.742 Pe -0.000 138 14-6 63.890 11-5 Pv CM 4.260 Q=339.21 7.64 C=120 0.026594 419-0'/z Pf 16.703 138 14-6 63.890 209-0/: Pe 5.448 282 1-11 86.041 11 fE(8-11'/2), 2P0(26-4), 628-1 Pv 2fEE(4-5/:), 2Ee2(5-3), fE(6-9/, CV(28-11 /Z), GV(2-7%2) FM 8.329 0=339.21 2.00 C=120 0.001016 21-10 Pf 0.055 282 1-11 86.041 32-0 Pe -0.000 272 1-11 86.096 2fE(16-0) 53-10 Pv MS 10.020 0=339.21 1.38 C=120 0.000413 20-2 Pf 4.536 272 1-11 86.096 67-0 Pe -1.635 312 5-8 88.997 3LtE(16-0), BV(19-0), BFP(-4.500) 87-2 Pv UG 10.400 0=339.21 1.28 C=140 0.000259 113-1 Pf 0.067 312 5-8 88.997 146-8 Pe 4.200 1 -4-0 93.264 3LtE(25-6), E(35-1), 2EE(17-6'V), S 259-9%z Pv so Route 2 DR 1.049 0=20.38 7.57 C=120 0.134776 28-1114 Pf 4.577 102 8-6 q=20.38 K=5.6 13.248 Spr(-13.248) 5-0 Pe -2.585 14 14-6 15.241 T(5-0) 33-11% Pv es Route 3 DR 1.049 0=21.40 7.94 C=120 0.147449 31-0'14 Pf 5.607 103 10-0 q=21.40 K=5.6 14.600 Spr(-14.600) 7-0 Pe -1.934 18 14-6 18.273 E(2-0), PO(5-0) 38-0'h Pv Route 4 DR 1.049 Q=21.63 8.03 C=120 0.150368 34-11% Pf 6.310 104 11-6 q=21.63 K=5.6 14.912 Spr(-14.912) 7-0 Pe -1.284 21 14-6 19.939 E(2-0), P0(5-0) 41-11% Pv car Route 5 SP 1.049 0=22.03 8.18 C=120 0.155675 5-9 Pf 1.517 105 16-5% q=22.03 K=5.6 15.482 Spr(-15A82) 4-0 Pe 0.865 12 14-6 17.865 2E(2-0) 9-9 Pv BL 1.610 0=22.03 3.47 C=120 0.019327 2-914 Pf 0.054 12 14-6 17.865 Pe 15 14-6 17.919 2-914 Pv car Route 6 DR 1.049 0=22.48 8.35 C=120 0.161569 31-41/2 Pf 6.202 106 7-6% q=22.48 K=5.6 16.117 Spr(-16.117) 7-0 Pe -3.018 33 14-6 19.300 E(2-0), PO(5-0) 38-4% Pv cio Route 7 (by ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11:27:09A M Page 4 Job Number: KS0354 Report Description: Ordinary Group II Diameter Flow Velocity HWC Friction Loss Pipe Type Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream DR Length Eq. Length Total Length Pressure Summary 1.049 Q=23.72 8.81 C=120 0.178426 107 9-0 q=23.72 K=5.6 17.942 Spr(-17.942) 25 14-6 22.542 E(2-0), PO(5-0) 32-0'% 7-0 39-0'/z Pf 6.968 Pe -2.368 Pv 06 Route 8 DR 1.049 Q=23.77 8.82 C=120 0.179094 108 10-0 q=23.77 K=5.6 18.015 Spr(-18.015) 26 14-6 22.891 E(2-0), PO(5-0) 31-0'/z 7-0 38-0'/z Pf 6.811 Pe -1.934 Pv 611, Route 9 DR 1.049 Q=25.42 9.44 C=120 0.202861 109 8-6 q=25.42 K=5.6 20.613 Spr(-20.613) 29 14-6 26.963 E(2-0), PO(5-0) 37-01/2 7-0 44-01/2 Pf 8.935 Pe -2.585 Pv Route 10 DR 1.049 Q=29.34 10.89 C=120 0.264359 110 10-0 q=29.34 K=5.6 27.444 Spr(-27.444) 32 14-6 35.563 E(2-0), P0(5-0) 31-01/2 7-0 38-01/2 Pf 10.054 Pe -1.934 Pv Oar Route 11 DR 1.049 Q=36.03 13.37 C=120 0.386581 111 8-6 q=36.03 K=5.6 41.389 Spr(-41.389) 16 14-6 53.349 E(2-0), PO(5-0) 30-7'/z 7-0 37-7'/z Pf 14.545 Pe -2.585 Pv BL 1.610 Q=36.03 5.68 C=120 0.047993 16 14-6 22 14-6 53.349 53.871 10-10'% 10-10'/z Pf 0.523 Pe Pv BL 1.610 Q=72.23 11.38 C=120 0.173775 22 14-6 30 14-6 53.871 55.748 10-9'/z 10-9%z Pf 1.877 Pe Pv BL 1.610 Q=109.03 17.18 C=120 0.372305 30 14-6 138 14-6 55.748 63.890 PO(8-0) 13-10'/z 8-0 21-101/2 Pf 8.142 Pe Pv s� Route 12 DR 1.049 Q=36.20 13.44 C=120 0.389989 112 8-6 q=36.20 K=5.6 41.783 Spr(-41.783) 53.871 E(2-0), PO(5-0) 22 14-6 30-7'h 7-0 37-7%z Pf 14.673 Pe -2.585 Pv (sip Route 13 DR 1.049 Q=36.81 13.66 C=120 0.402231 113 8-6 30 14-6 q=36.81 K=5.6 43.203 55.748 Spr(-43.203) E(2-0), PO(5-0) 30-7%z 7-0 37-7%z Pf 15.130 Pe -2.585 Pv frg iva[e pe l e tl § at '' v. s 12}oi) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter 1 4 87 /1 = Factor 1 Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11: 27:09A M Page 5 Job Number: KS0354 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Length Eq. Length Total Length Pressure Summary tp9S`i:;� AO BL CM DN DR DY FM FR MS OR RN SP ST UG Arm -Over Branch Line Cross Main Drain Drop Dynamic Feed Main Feed Riser Miscellaneous Outrigger Riser Nipple Sprig Stand Pipe Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV AngV b BaIV BFP BV C cplg Cr CV DeIV DPV E EE Eel Ee2 FDC fE fEE flg FN rr g GIoV GV Hose HV Hyd LtE mecT Noz P1 P2 PIV PO PrV PRV red S sCV Spr St T Tr U WirF WMV z Alarm Valve Angle Valve Bushing Ball Valve Backflow Preventer Butterfly Valve Cross Flow Turn 90° Coupling Cross Run Check Valve Deluge Valve Dry Pipe Valve 90° Elbow 45° Elbow 11%° Elbow 22'/:° Elbow Flow Device Fire Department Connection 90° FireLock(TM) Elbow 45° FireLock(TM) Elbow Flange Floating Node FireLock(TM) Tee Gauge Globe Valve Gate Valve Hose Hose Valve Hydrant Long Turn Elbow Mechanical Tee Nozzle Pump In Pump Out Post Indicating Valve Pipe Outlet Pressure Relief Valve Pressure Reducing Valve Reducer/Adapter Supply Swing Check Valve Sprinkler Strainer Tee Flow Turn 900 Tee Run Union Wirsbo Water Meter Valve Cap 1 © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11:27:09A M Page 6 Job Number: KS0354 Report Description: Ordinary Group II Supply at Node 1 Pressure, psi c cn o $i 8 w `S 8 a' `1i1 C 1111111111111111111 111 1 1 1 t t t111111111111111111111111111111 I I 111111 III A 11111111 111111111111111111111 Static Pressure 140.000 .589.2 339.21 with hose @ 93.264 streams System demand curve 10900.00 @ 20.000, 1 11111111 I 11 1111 11 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111111111 L L 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V pU1.11111))II i1oo22M 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.457 @ 589.21 System Demand 339.21 @ 93.264 System Demand (Including Hose Allowance) 589.21 @ 93.264 [y ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11:27:10A M Page 7 Job Number: KS0354 Report Description: Ordinary Group II © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11:27:11 AM Page 8 1 V T s IL DDITI ON AR SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FIRE ALARM SYSTEM PLAN SHEET INDEX 16 Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject ro errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions ; revisions to these drawings after this date will void this <cceptance and w l require a resubmittal of reviseo drawings for subsequent approval. Final acceptance is subject to fleld test ano Inspection by The Tukwila Fire Prevention Bureau. Date: LI,).,o'1ii By: 511 WI QVILS. FIRE. DEPA4: IEP'T eaW� CAI 206-575-M7 •'!VC: t tiS Fix; ; I' ei 1.t No. 0 -:d address for shut .aUwn or reStoration approval, SCHEDULE A\ D COI\ D U IT FILL CHAT SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 1 E E E 2 E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 8 FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2 EXTN CEILING ®E D DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM E DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS EXISTING VERIFY IN FIELD HT -R INTERFACE MODULE E WITH RELAY (EXISTING) HTRI-R SIEMENS EXISTING VERIFY IN FIELD FIRE ALARM STROBE (EXISTING) ZR -MC -W SIEMENS EXISTING CEILING FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -W SIEMENS EXISTING 80" A.F.F. TO BOTTOM 8E FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING DE TENANT J -BOX (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 1 • ORGANIC NAIL BAR 426 / SPACE #1000 SSS T F 5' + WIRE DESIGNATION GENERAL NOTES i = """""" 10B NUMBER: 31724-1 J �.. SHEET FA -0-1 u Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ../(� PAID APR 1.1 2 15 LIKWI LA FIR=-. z 0 z_ w Q w 6 V J N) FAX (206) 628-[.990 RELEASE/REVISIONS REV. BY: I WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 1 E E E 2 E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 8 FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2 EXTN CEILING ®E D DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM E DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS EXISTING VERIFY IN FIELD HT -R INTERFACE MODULE E WITH RELAY (EXISTING) HTRI-R SIEMENS EXISTING VERIFY IN FIELD FIRE ALARM STROBE (EXISTING) ZR -MC -W SIEMENS EXISTING CEILING FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -W SIEMENS EXISTING 80" A.F.F. TO BOTTOM 8E FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING DE TENANT J -BOX (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 1 • ORGANIC NAIL BAR 426 / SPACE #1000 SSS T F 5' + WIRE DESIGNATION GENERAL NOTES i = """""" 10B NUMBER: 31724-1 J �.. SHEET FA -0-1 u Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ../(� PAID APR 1.1 2 15 LIKWI LA FIR=-. z 0 z_ w Q w 6 V J N) FAX (206) 628-[.990 RELEASE/REVISIONS REV. BY: I 0 DESCRIPTION SHOP DRAWINGS DATE 03/26/18 2 aaaaa 0 _ CC z o _• 0 Lu T Ct.O E0 cLz w 0 ® < 4- • 2 J C'3 Z (yW dz o u) w ¢ Z `__ CC Ili I- Q Ll. oH t4 (CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 03/26/18 BACKROUND PLAN PROVIDED BY: SITE PLAN Cc zov THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. PUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ TUBE OUTLET SAMPLING TUBE INLET__. SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL DEDICATED EMERGENCY , FROM EXISTING MAIN FACP C CABLE C' CABLE 0 aj „Diu GRD N L 0 PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 B m 1 & 0 0 0 (-) (+) (-) (+) HARD LID CEILING HARD LID —\ SPEAKER SUPPORT TILE BRIDGE NAC S4 2, NAC S3 NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) (+(-) STROBE SPEAKER (+) FROM PREVIOUS ADDRESSABLE 2 DEVICE TB1 0000TQ0 00 NO COM NC EOLR 470 0 TO FAN SHUTDOWN + eTONEXT e ADDRESSABLE DEVICE 0 2 3 4 O O e HTRI-R r - 0 NO 6 COM B NC ® TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (+) ( ) STROBE SPEAKER (+) (-) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 RELEASE/REVISIONS IREV. BY: SWITCH + - INPUT LED TSM -1 0 TO FAN SHUTDOWN + eTONEXT e ADDRESSABLE DEVICE 0 2 3 4 O O e HTRI-R r - 0 NO 6 COM B NC ® TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (+) ( ) STROBE SPEAKER (+) (-) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 RELEASE/REVISIONS IREV. BY: DMG DESCRIPTION [SHOP DRAWINGS UJ I- < 1 03/26/18 aaa<a Cif) 74Z w 0 z o T 00 cr z co < 0 w F-- 1-= Orn 0CLz ci) o O dCz w�z 2 z� r� <tU� 111 O uoH CV 3 4-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 03/26/ 18 BACKROUND PLAN PROVIDED BY: �OB NUMBER: 31724-1} SHEET FA -02 Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps A B C D E F G H 1 J K FIRE ALARM BOOSTER Project: ORGANIC NAIL BAR Panel: EXISTING BPS PAD -3 Date: March 26, 2018 Module/Device POWER REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 725 2 aaaaa Total(A)= 15 Total(B)= 865 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 865 Total current ratings converted to amperes (line D x .001) 0.015 0.865 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.0720545 Add lines G and I Total Standby and Alarm AH 0.4320545 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.5184654 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 CALCULATIONS Notification Appliance CircuitDetai PROJECT: ORGANIC NAIL BAR Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLE Date: March 26, 2018 Wire Resistance 2.58 CURRENT TOTAL= 725.00 1 SET -MC -CW @l5cd 1 SET -MC -W @15cd SET -MC -CW @75cd 2 SET -MC -CW @95cd 1 ZR -MC -W @ 15cd DEVICES 5 TOTAL Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 69 64 200 264 64 A= 69 64 0 528 64 725 14 289 22.92 725 ( WL *2 )* (Rift) (Total Cct Load) (E=I*R) 24 - E) 1.49 0.73 1.08 22.92 TO EXISTING POWER SUPPLY TO EXISTING SPEAKER CIRCUIT TO EXISTING DATA LOOP S,V S1-1 15Cd S1-2 15Cd S1-3 15Cd S1-4 S1-5 95Cd 95Cd EOL S1 D,I 21� ITSMIE SINGLE LINE DIAGRAM E FLAG NOTES: EXISTING RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. Eft 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622--6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE co N M O 2 aaaaa I� z co E E2 w U 65 0 cc Lcic-i Oi �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 03/26/ 18 BACKROUND PLAN PROVIDED BY: \0B NUMBER:31724-1} SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved TO TENANT JUNCTION BOX S,V --o S,v- 8 S1-4 95cd S1-5 95Cd S S,v FIRE ALARM SYSTEM PLAN FLAG NOTES: EXISTING RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. FAX (206) 628-4990 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 03/26/18 2 aaa<.a " �1 0 0 0 T CC 4f -; Q r Uc0 0 z l 0 0) 0 Z W Qz 0) W Q z cLO CC WFC © LiOH cn N of) >4, (I) CC LL �CALE:1 /4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 03/26/18 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 31724-1} SHEET FA -04 Pro rieta and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved r q Of It EXIT EXIST NG 2'x2'. CEILING TILE 10®" l F F X_ 0__ "dXISTINI CEILING 11'-10"A 2'x2' TILE F DRY WALL CEILING 11'-4" A F F REFLECTED CEILING PLAN SCALE: 1/4"=1'-0" QI Design per NFPA 13 — Ordinary Hazard Group 2 — Light Hazard All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions Ac_ a4A Wiiheut Comments ❑ As Noteo h Re ❑ Per The Attecn tetter These plans have heel reviewee t The T ukwlla Fire Pr3ventton Bureau for conformancE 1, tp current City Acceptance is si.ib ec* to &Tors ar'd c tiv�- oris which Cr' r or a>>trtorl<e violations cf adopted loaras ar _C? o _ ; Pisces Tne i espC:"s'b' 'ty for the d�..>.t; Of oe sg . e totall"i with tr a�y A Itrt rs, , e.e tiO ;5 ; e =Islons to tree erawings after til:: Gad ori t void tr.sacceptance atid at"t' reouire a resubrnittai of r:-:.visec. e.rawir as for slucy-equr't approval. Final ac: eptance is suo)ect to Heid test and inspection:by The Tukwila Fire Prevention Bureau. Date: CI _3 -18 By: rFlexHead Sprinkler Drop Corrugated stainless steel hose with stainless steel bre available in 2', 3',4',5' & 6' Iegnths Adjustable Hub Multi -Port Bracket • 1 — Add Reliable Model G5-56 Quick Response Concealed Pendent 1/2 x • E — Existing no change i-LFEA3 71 tI 1IR IES ," Flexheadtommercial Ceiling Unit T -Bar Ceiling Installation Model t# 2024,2036,2048,2060,2072 r ORGANIC NAIL BAR 426 Southcenter Mall, Tukwila, WA 98188 ilol uioR1 i = _i at hili ...... .,r,. r�� apt■ n � Jlryp )i ' ! �,.. ORGANIC NAILS BAR KEY PLAN ..niefferucmi, FIRS PROTUCT1014 YPRN+KUGe SYSTEMS John J. Abel 9700 -0681 -CG Level3 Crown Fire Pietection, man ,a 0, ix s,..•!.14 w.yr >�' P . •o.• NCY I- Fl"2.1i UTtiC.7':c1At 5.Yrtiwhit iw rivarruo Jnh rw 0 A' 41v ?/8C, -0591-C'0 !vv. ' Crc 'r I :rn i .t31.,6 -ri, tiro. CPC vit!Ekte ,..L _ - , at TWA..al0 • • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 ORGANIC NAIL BAR 426 Southcenter Mall, Space #1000 Tukwila, WA 98188 PALO HA :1 2e!L 'U LA F1,q E -7/---/M(7 DATE: 3. l DRAWN: SCALE: I / 6 t / rt 2 FI E S ST M TUKWIL SHINGTON SHEET INDEX GENERAL NOTES SYMBOLS .LEGEND SHEET \UVSHEET TITLE SYSTEv TYPICAL I\FOMATIO\ DETAILS - WRING A\D MOUNTING FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE IINITIATING DEVICES UNTIL PREPGRAMMED .WITH DEVICES 'ADDRESS. QUANTITY SYMBOL DESCRIPTION FACP FRE ALARM SYSTEV FL00H PLAN SYSTEM CALCULATIO\S 1. NUMBERS . ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND 'DEVICE ON ADDRESSABLE LOOP 1. .I 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH.. THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL 'CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E.., CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD. BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. GE\ EAL), �ISE� SITE PLA\ VOlhout•y ❑As Nc'.` ❑ Per (i •I"4'.C.4iii:.%�: ..4. ,.t i nese piens I,�' �';. I ..JI: i • ;4:,0b Fire Prevention I:;;tr,: ,:; t w;IJi cur( t ntcity standards. , : r rc r...rd omissions ef adopted star da; ,: .. ; , ir. , . i ' ,i.. r.' 'tOr the adequacy o..+.. Additions, 0 I: ass: _ i,::<<: st3 c:Z,v.;r;gs ;atter this data Will 1 t1!: ti f... JE:... : .Ci Ci titt e rt-4LC,:e resubmittal of or,,,..v ng;s tor subsequent approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presentaP. to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. Final acceptance is sr.tb ect to field test and inspection by The Tukwila Fife Prevention Bureau. Date: S- 0 By:AVv\511 :.UKWILA FIRE DEPARTMi 1 call: 575-440Z nd give this job art.i oxact address for shut 1 r.,., an or restoration approval/' WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CO\DUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD 4#12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD *16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR 4#14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED 4418 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAVI OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SI IALL DE MOUNTED AT 48" A.F.F. TO TI IC ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED 2 2 2 EX BPS FIRE ALARM REMOTE ANNUNCIATOR REMOTE BOOSTER EX POWER SUPPLY SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP. CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD F -13 -‹LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD IA SMOKE DETECTOR HFP-11 W/ SIEMENS V�1 (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE AD DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING Ec FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. Ec FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM SET -HMC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. n c FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING L FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX IN/ 1-1/2" EXT. CEILING Q FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM TIO WP FIRE ALARM STROBE (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.❑. F,B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U,❑.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAO t",4.; 15 2008 COAA- �kwil41f��rC 2- t Copyright 2006 by Guardian Security Systems,Inc. All Rights Reserved RELEASE/REV m LIJ cr DESCRIPTION z Q SHOP DRAWINGS Lu a 0 N 0 0 z (SCALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: �OB NUMBER:54557 } THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL DR PREVIOUS ADDRESSABLE DEVIC END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH 0 DUCT DETECTOR LDCATI❑N GROUND 0 0 0 r� 0 0 0 HTRI-R 01 STATUS LED Oo 0 N.O. 0 0 1 COM N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL 0 LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE_ DEVICE TO NEXT ADDRESSABLE r DEVICE L + NOTE 1: VOLTAGE MAX, - CURRENT MAX: - CONT: RES. MAX. - MAX, CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN, LINE SIZE- OUTLET SAMPLING ', TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE MUSIC 11 -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING 0 TO NEXT ADDRESSABLE DEVICE f(+) ik STOP IF LAST DEVICE O FROM XLS CONTROL PANEL OR''' PREVIOUS ADDRESSABLE DEVIC{(+) (-) RELAY CONTACTS (4.OA @ 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 rnA DURING POLLING 10 OHMS 200 FT. (18 AWG) (102uF 0,D4uF 14 AWG 18 AWG NOTE 21 ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST 25 SEC, TO GUARANTEE DETECTI❑N, 1001 TB1 00 00 123456 HC TB2 ma{46�0� 654321 0 /2 END ❑F;'LINE DEVICE (3.6K 1/4W) SUPERVISED 1 SWITCH GROUND 0 0 0 HTRI-D STATUS LED CO 0 r-- 0 1 1 NOT USEDi ' CO 0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC 0 0 _L J_ L TT' 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+. 1- 1 2+ 2- 2 NC C NO + + - + - + - + - 0 0 0 0 1-g- _2_ 24K g- 24K + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE NAC -4 NAC -3 2 NAC -2 NAC -1 END DF L.IN,E: DEVICE 316K 1./4W) s UPERVISED &WIT:CN , FRONT VIEW 1 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE POWER SUPPLY C'S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) 470. OHMS EOL TS M-1 0 O 0 1111 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE C ., (S ) STROBE SPEAKER () STR❑BE-) EARTH'.-, GROUND -›-(+) TO NEXT DEVICE OR l —�(-) STOP IF LASTDEVICE (+) (-) STROBE SPEAKER (+) (-) SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE ---...... OR STROBE ONLY F R 0 SPEAKER/STROBE 4S DEEP BOX w/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE j' TO NEXT J' DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TING TEMPERATU E: +32•F (O' C) TO 100' F (38' C) HUMIDITY: UU0-933% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE r DATA IN (-) > it DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD r SMOKE DETECTOR: BASE TO NEXT DEVICE*— REAR VIEW > (-) DATA OUT > (+) DATA OUT HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID ---- CEILING SPEAKER SUPPORT T . E: BRIDGE HARD LID 4' SQUARE DEEP BOX' WITH 1-1/2' EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTION BOX MOUNTED ON \ CEILINGI FLEX \ / / / / JUNCTION BOX / MOUNTED AGAINST / CEILING SUPPORT iI / T❑ NEXT DEVICE ' 0 O CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING DO NOT NSTALL ADDRESSAB_= ILII- A DEVC=S UNTO PREPROGRMM-D WITI- DEV C=S DDRESS. N G oe • z• N C)I•X L1_ LU Q W (.) 10 q) N ui N > Q ►- O • Cn N• • W RELEASE/REVISIONS CO w z DESCRIPTION SHOP DRAWINGS I- Q DRAWN BY: (:ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: II. �OB NUMBER:54557 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved.- :1C e ' ; • , ! 1 1 I , • B."7) I.; 111 1:• 1 :11 • ,11 .1 •.;{ 1. ' ..... ..... );,....—/ 4 2S, i ,--•:'-' .-- ',1,--3- NO:CNC:P.1C r• 2S,2V 2s 15 R. M • 75 C.11119. 1.5 -1) 11 ...... - .3 ...... ..... 1 I / E>14M JT .1 -- ',LES (1) 1••;.e 2S El CA131-1wRAP •,/ f 1,1 , ( ...\,:',-./' x • 1 .,,.--"jES1AURAN• ,,:..'l / '3;HULATioN Room ,,;-•'..• Pi 1.0111‘1C.,F, 111 /1! , -111 e • I UNDS HEARING WESTFIELD SOUTHCENTER MALL 11: "11 j. 111 '11 1,1 k • .11; : ;1. I . . 1 , , I ;,11,-.:1' • 1 . I , ' 44 ITAG NOT .1-j-"1".• • • 11 , • tit:: 1: 111:1; [8> FIELD LOCA TE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNIT S.(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY ESS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLA TOR FIRE SUPPRESION SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. I.:• , DO NO I\S LL ADDRESSABLE \H I DEV CES PREPROGRAMMED W DEVICES ADDRESS. AT Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved,; (/) z (/) LLI uJ (/) LL1 uj Ct CO CO Z •FTS EE LT, 6 w 1-2 2WI o(/) (/) z ify co O 412 1— UJ DRAWN BY: I.ANDERSON DESIGNED BY: R.VEZZANI DATE:5/12/08 BACKROUND PLAN PROVIDED BY: ..JOB NUMBER:54557 r• SHEET .1 ;'!1111:1 -11111:: z < . DESCRIPTION SHOP DRAWINGS , . al ‹1— m 5/12/08 CO CO Z •FTS EE LT, 6 w 1-2 2WI o(/) (/) z ify co O 412 1— UJ DRAWN BY: I.ANDERSON DESIGNED BY: R.VEZZANI DATE:5/12/08 BACKROUND PLAN PROVIDED BY: ..JOB NUMBER:54557 r• SHEET .1 ;'!1111:1 -11111:: a., I ID 02 RS R !E \ S•I ION D/`; D CL) Lii< L VLF.' WIIEESS ELEC I'v1 ADE IN WA 21-1I 02; FON 28.50. Firii31-1 Floor E',E.'voision THREE I i•-:`,/E1..S 1 7,(1.,‘,3 NORTH [ TRASH -'&," ------ -•, LLJ 1.1.J LLi MALL PETZI TR ------ L MALL ZOUNDS HEARING •-• •. ) '1010 15001 ...... IfL Trli. ET LNI 1550 H1020 FQ, • LE -j 10 0] ID] 154-5 L ; ' ',SEATTLE 1\,1t-s,RINER`:_; 7-11/2\1\A pAD01C., SUN] VVE THE VV4,,1.V NJ L 1 100 bebe 111 •Lry,- ---- -- if) - ZOUNDS HEARING WESTFIELD SOUTHCENTER MALL ---------------- m • • ft 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V orr C 110 75 15 15 15 15 15 15 30 EOL -S1 30 2S,2V-(=> FA BOX FACP EX D TS DI 21 SYSTEM CALCULATIONS • : ! 11 ZOUNDS HEARING . . „ , ,.. . , „ -, , , , : . , . , '•'':11---:1 I'l: : CURRENT TOTAL= , ZOUNDS HEARING H . - , ZOUNDS HEARING SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations ! . • . FACP ADD ONS , , . •- <<<< QTY. Device Type Alarm Current : , _..._ VVire Length Voltage at EOL Circuit Total , Current Load : r 64 0 :, ' Standby:, : Alarm: Current Load: 0.86 SET -MC @3OCD. Standby: Alarm: .: , •: , ( WL *2 )* (R/ft) 1 0 SET -MC @75CD 175 175 : Total Device Load, Amps (I) 0.99 SET -MC @110CD. DeVce Type 0 Qty Amps : : : 'Total Amps Total , . Device Type 318 Qty Amps Total ' Amps Total Voltage Drop ( E ) 0.85 0 , . , . •' . , ' . . , HEP -11 . 0.0022 0.0022 . 0.0023 0 Main System Board 1 0.03 , . . .. ,. 0.03y 0.030 ' 0.030 • „ 0 AD2-P , 1 0.0635 - 0.0635 0.064 0.064 . •I. SET4/IC @l5CD0.064 i 384 , 4-10 HTR -R • ; 98 2 0.009600. 0.0096 0.021 0.042 ' 1SET-MC @30CD 2 , 11233 . , , 0.098 0.196 • ___ HTRI-D . ----7- 0.001600 10 : 0.0035 988 12 SETi-IVIC 75CD 1' 1 • ---------- . , • . ' . ', , 0.175 0.233 0.175 0.233 i. ,'. ICP -B6 ,: Detail 0.005 SET4/10 0CD 10 WESTFIELD SOUTHCENTER MALL , . . , 1!, SET-C@115CD SETiIHM-CC@135CD • Panel: ZOUNDS HEARING' , : - , Wire Resistance 28 •i ::, l' 0.318 Date: May 13, 2008 . CURRENT TOTAL= 7.2 CIRCUIT: SPEAKER CIRCUIT . .. , . 0.318 i • . . . .. . 1 :: " . • , • •-• ., QTY ...,.,:. : Device Type ... ..: • 'Alarm' Current . 1 1' SET.HMC-C@185CD , .__ ,..._ _ Voltage at EOL Circuit Total • ...„...... 0.445 1 . 70.7V 1/8 1:8 7.2 . 0.0731 Amps 0.106 Amps: ZR -MC @'.15CD 0 6 0 • , 0.064 0.384 : 1; " „ . r , r r , • 1 0 ZR -MC WOCD . Total Device Load,Amps (I) 0.01 0.098 ' 0 : Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours . HCP; ' , 0.0015 Voltage Drop ( E ) 0.02 0 .1' . ' 1 '• „ , 0.03 Amps 1.018 Amps ' : Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours -1.1; 0 • 0 0 0 - T , . Standby Current Load: 0.03 Amps For:24 Hours = 0.720 Amp -hours TOTAL mA= 7.2 ,, . 20.37900912 7.21 25% Derating= 2.204 Amp -hours .• :,! '1;.' : 1J • 1! Alarrn,COrtent Load: 1.018 Amps For -5 Minutes= 0.086 Amp -hours . „ , Total System Current Load: 2.204 Amp -hours . ' 11 25% Derating= 1.007 Amp -hours j i H • Battery Pair to be Used: 12VDC Amp -hours 7AH 1, . . Total System Current Load: 1.007 Amp -hours , . . , 112VDC _ Battery pair to be Used: Amp -hours 7AH . .'; BATTERY SIZING CALCULATION Panel: ZOUNDS HEARING , - - - . , . , . 'Wire Resistance 'I'A ' . - 7 _ ---- - ---- - ----- - Date: May 14,2008 : CURRENT TOTAL= , 988 - _________ ciRcUit. si . • . , , . •- <<<< QTY. Device Type Alarm Current Alarm Total Wire Size _..._ VVire Length Voltage at EOL Circuit Total 0 2 SET -MC @15CD 64 0 . ,_____ Total Wire Resistance ( R ) 0.86 SET -MC @3OCD. 98 196 _.. _ ( WL *2 )* (R/ft) 1 0 SET -MC @75CD 175 175 Total Device Load, Amps (I) 0.99 SET -MC @110CD. 233 0 : (Total Cct Load) 0 SET-HMC-C@115CD 318 0 Voltage Drop ( E ) 0.85 0 SET-HMC-C@177CD 445 0 . . , • (E= 1 * R) 0 SET -HMC @135CD 318 0 EOL Voltage 19.55 0 . 6 SET -HMC @185CD 445 „ 0 (20.4 - E) Z-MC@15CD 64 i 384 4-10 Z-Mb@a0CD . • ; 98 , . ; 0 ' ' ; ,SET-MC-CW@110CD. 11233 ' 233, • . ----7- DEVICE8= 10 : TOTAL m A= 988 12 7 265 7 19.55170321 988 • ---------- . : .'Notification - Appliance --------- Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL , . . Panel: ZOUNDS HEARING' , : - , Wire Resistance 28 Date: May 13, 2008 . CURRENT TOTAL= 7.2 CIRCUIT: SPEAKER CIRCUIT - -...J.L . . . .. .. . . . . . •.• , .• . . . .• • ..,. .. • • ......„......„....•.. . • , • •-• ., QTY ...,.,:. : Device Type ... ..: • 'Alarm' Current ... Al arm. Total Wire Size • Wire Length, , .__ ,..._ _ Voltage at EOL Circuit Total • ...„...... 4 70.7V 1/8 1:8 7.2 Total Wire Resistance ( R ) 2.92 0 0 0 ( WL * 2 )* (R/ft) 0. 0 _. Total Device Load,Amps (I) 0.01 ' 0 0_ (Total Cct Load) • 0 0 _____________________ Voltage Drop ( E ) 0.02 0 (E= I * R) O 0 0 0 - -0 , ' EOL Voltage (204 - E) . 20.38 0 • 0 0 0 - T , . DEVICES= 4 TOTAL mA= 7.2 1456 1,. 5 1,11;', 20.37900912 7.21 ,k„,•••• row* •]-11('" ONS REV. -BY: I NVI DESCRIPTION SHOP DRAWINGS W I - <t D 5/12/08 < <<<< co CO _J R; Z CC LT1 2 6 < LCE W `21 1.± ocn (I) i< o < 15 D a-. ,„ O ilJ IL ; SCALE:11,18 =1 DRAWN BY: I.ANDERSON DESIGNED BY: R.VEZZANI DATE:5/12/08 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM VOLTAGE DROP CALCULATION \z1.0B NUMBER:54557 ,Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved - - _ SHEET Zounds w N VICINITY MAP (Suite# 426) SCALE: NTS General Notes 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. ZONE T-2 a 0 c-FFL^= rttr 1- 4= Without Cornments AS Noted In Red Per Thtz, cl.<_;Letter mese plans • Prevention standards. omissions starraaras an adequacy of ., Additions, ( . 1 1 Fire :city ,doptcd i, fort;t d...:'Ini'i. .. i'i+;i: lir lt'iillji' uticir this date 'viii - - ,c;<_: ,l l,,fill rt_:.qtilro o I resubmittal o; s:: --±;;, a:. i4 v -:j lot vut;sequl nt i ipprovr 1, ; Final acceptance it :ziti'itot to field test t4nd inspoctioon by The Tukwila Fie Prevention Bureau. ( C Weld stamps must be inspected before pipe is hung. Do nQt paint piping prior to hydrostatic test approval. TUKWILA FIRE DEPARTMEN1 Please call: 575.4407 and give this job/ No. o S -S —/ and exact address for shut' /own or restoration approval, WEST RISER DETAII HYDRAULIC REFERENCE ONLY NOT TO SCALE EGRESS CORRIDOR FlM91E0CEueiG'rEl(i<T r5•-0•AF F. \ I TOILET ROOM .`_GYP. P.D. CELLO TB APF WITH PIATFORII c :i41` OFFICE rag sG•E0 CEL0MDGHT 5'0'AFf. BREAKROOM FINISIE0031P43 i-EGHT Ordinary Group Il•r,.20gpmlft2 for 948.00ft2 TEL/DATA CLOSET CPU,' TO OEGC CONSULTATION F CUSI "e O CEILING IE°HT S yeAFF. LLL AUDIOMETRIC EXAM f- AFf. AUDIOMETRIC EXAM FiNIf.,4E0 CEILING HEIGHT., .6.: dB Al• AUDIOMETRIC EXAM FWSi&OCEANG HEIGHT b-,• if -6" AFF. SALES AREA FINWE0 CFILFrcGiSJGFR 1 otuF. DEMO ROOM .1„6-, FIN44E) GERIGItEGHT . 10t AFS. \Jr SOFFIT :B i F01i4'FDCEel-CG HEIGHT `ILL IOt AFF. 11-10 ]WAFT. ,e, zt F08SIiEDC0UN0Hmrt 1-- 5-1PAFf. SOFFIT 1 F92SHE0 CEIl+TG HEIQ4T Pt ALF. .lL'- A =' ,-1-(`;.P• .l/:f SOFFIT FI4t9<EDCEIL1,4 IEciT0 J 9,10. AFF. L lI RESTAURANT SIMULATION ROOM . FWIs#D GEAIGHEIGHT t0 -P AFF. SOFFIT F00aC2,CELUGtfIGHT • SOFFIT FleiSSNEJ CVONO HEGHC-e.71 10-41. AFS. •I SALES AREA Flws1E0cEILu4G FBGHT= 1f 1•AFF. FIRE SPRINKLER SYSTEM -17 AFT TYPICAL FLEXABLE SPRINKLER CONNECTION. FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE.. FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE //////////////j/_T E gigue F10.909 SWIVEL SWAY BRACE FITTING 132,61 BRACE PIPE FIG.1000 "FAST CLAMP' SWAY BRACEATTACKMENT LINE PIPE LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE Zounds Remote Area: Retail # 426 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY cuss ORD HAZARD II MAX. COVERAGE per HEAD 130 ' DENSITY .20 GPM r Ft' for 948 Fe F SPRINKLER Reliable Model G4A ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER. SYSTEM REQUIRES: 339.21 GPM © 88.99 PSI At time of Design 11'-6" CLG.=37.75% AREA REDUCTION 3B- KWIK BOLT (2 IM• EMBED LENGTH) FIG.809 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT FIG.4A PIPE CLAMP FOR SWAY BRACE LATERAL BRANCHLINE RESTRAINT BRACE PIPE i i NQY-THREADED BRACE PIPE LATERAL BRANCHLIN NOT TO SCALE RESTRAINT Hanger No. 07C HILTI Kwik Bolt III Cut Rod Lgth Rounded to Nearest Inch Drilled Anchor i // Rod Coupling Al Thread Rod Swivel Ring ‘1/4„ Concrete f Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE .... 2008 446°0 Doges tvl Wa Fire Adam Kantner Marco Contractors SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE N0. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE R5415 24 5.6 Pendent White 155°F G4A Concealed APPROVAL: City of Tukwila 0 HYDRAULIC REFERENCE POINT Upright Chrome 155°F F1 FR Upright CONT. NO.: KS0354 Total = 25 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RES t NAINT SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 05/01/08 Western States Fire Protection Company 7102 180th AVE NE, Si t 4105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED IH ¢/AIISTYI/DALLAS/DECATUR/DENVER/DULUTH/HOLSTON/KANSAS CITY LAS VEGASfMWNEAPOLIS/PHOEN X/PORTWtD/RAPID CITY/ST. PAIR./SALT LAKE CITY/SEATTIE Phone: 425-881-0100 Fax 425-881-3030 Zounds 426 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SHEET 426 SOUTHCENTER MALL ASSOCIATED PERMITS 18-F-080 08-F-203 18-S-058 08-S-166 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: ek-a Q • t A, 1( kDJ\ Suite Number: IiOW Floor: Tenant Name: CA T.AVC1 KVAil C New Tenant? ❑ - Yes * No Property Owner's Name:\ Q e),C\ TACc4eXt i ' Mailing Address v Wk ` D t D )0kC `_)XXJI RAO City State Zip CONTACT PERSON -if there are questions about the submittal. Name Q ! Company Name: l�lua-cv DLf\ 1 asJ'F-C.I►(yD Day Telephone:42a.Q- (,P `� 9`4t p Mailing Address: VI \* -ANtQ, • ` r E-mail Address:lT City State Zip �C 1� Y�1JC� CRCC 1 c c' rn [ . C.Ut`c1 Fax Number: �ntractor's City of Tukwi NICET III number: Business License number: — rite( 5+ Total number of new/relocated devices or sprinkler heads: 3 Valuation of Project (contractor's bid price): $ • W Scope of Work (please provide detailed information): Q, cOlocitm X\Cl J11\k- CVoN12x`y,[moi ccL5 PERMIT APPLICATION NOTES Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: W.(fll`� Date: t I 6 U ,( Print Name-eb•W Day Telephone: ?CU-- Plan C fj-- Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 1A h'1a11 Suite Number: i Mr) Floor. Tenant Name: O ra aQ n (✓ �,\` �' New Tenant? ❑ - Yes ❑ - No Property Owner's Name: \V44 Yp 1 Y l/1-� r Mailing Address: 2)0 SQ >+h Ma.)' /C, t}))'" City Sty Ap CONTACT PERSON -if there are questions about the submittal. Name: C'r \ GJ 1 1'l✓ 06316%44. Company Name: Mailing Address: E-mail Address: Day Telephone: 1.4 2 L-1 •76 (09 Ciro 1,0'1 'F-re,T tot e,.. -Ax or) 1 nc_ J JP City State Fax Number. Contractor's City of Tukwila NICET III number: 6t?(po • E5a i Cc, Business License number. 2,\.)5. D1 9 5$')Z Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): Sll V t0 Scope of work (please provide detailed information N6A_ � .�1� cS�� 1 n r h'C PERMIT APPLICATION NOTES Value of Construction — hi all cases, a value of construction amount should be eote<ed by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the watt authorized on the site by midi permit is wed or abandoned for a period of 180 days after the time the work is commenced The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 OR AU ZED AGENT: Signature: 1?/W°- Print C° -Print Name: VkScirA Ar7so7) Plan Permit App.doc 8/22/14 Date:. •ZI ` t Day Telephone: 112.5-'yv%710(21 TFD FP Form 8 • FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Zounds 426 Southcenter Mall Permit No.: 08-S-166 Date: May 5, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • .• • • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. Job Number: KS0354 Report Description: Ordinary Group II Job Number KS0354 Design Engineer Adam Kanter Job Name Zounds Hearing State Certification/License Number WESTESF136QF Address 1 426 Southcentner Mall City of Tukwila Address 2 Job Site Southcenter Mall City Tukwila State Wa Zip Code 98188 Drawing Name FP-1.cad Ref Most Demanding Spnnlder Data 5.6 K -Factor 20.00 at 12.755 Occupancy Ordinary Group II Hose AJlowence At Source 250.00 Density 0.20gpm/ft2 kea of Application 948.00ft2 (Actual 948.46ft2) Addigonal Hose Supplies Node Flow(gpm) Number Of SprinIders Calculated 13 Coverage Per SminIder 1 00.00ft2 Total Hose Streams 250.00 System Flow Demand 339.21 Total Water Required (Including Hose Allowance) 589.21 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 36.27 between nodes 137 and 32 Maximum Velocky Under Ground 1.28 between nodes 1 and 312 Volume capacity of Wet Pipes 2041.27gal Volume alpaca,/ of Dry Pipes 0.75ft' Node 1 Hose Flow (gpm) 250.00 Static (psi) Residual @ Flow (psi) (gpm) Available Total Demand (psi) (gpm) 140.000 20.000 1 10900.00 139.41 589.21 Required (psi) Safety Margin (psi) 93.264 46.193 Contraclar ......... Contrector Number KS0354 Contact Name Adam Kantner Contact Title Project Manager Contactor Name Western States Fire Protection Phone 425.881.0100 Extension Address 1 7102 180th Ave Ne, Suite A-105 FAX 485.736.9032 Address 2 City Redmond State WA Zip Code 98052 Web -Site M E P . CA D, Inc. AutoSPRINKO VR5 v5.2.6 04/29/2008 11:27:06AM Page 1 Job Number: KS0354 Report Description. Ordinary Group II Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) Sprinkler 105 22.03 20.00 5.6 15.482 i 411 Job Number: KS0354 Report Description: Ordinary Group II Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 12 14-6 E(2-0) 17.865 14 14-6 T(5-0) 15.241 15 14-6 PO(5-0) 17.919. 16 14-6 PO(5-0) 53.349 18 14-6 PO(5-0) 18.273 33 14-6 PO(5-0) 19.300 21 14-6 PO(5-0) 19.939 22 14-6 PO(5-0) 53.871 25 14-6 PO(5-0) 22.542 26 14-6 PO(5-0) 22.891 29 14-6 PO(5-0) 26.963 30 14-6 PO(5-0) 55.748 32 14-6 PO(5-0) 35.563 137 14-6 2P0(8-0) 63.742 138 14-6 2P0(8-0) 63.890 272 1-11 T(50-0) 86.096 282 1-11 P0(26-4) 86.041 312 5-8 BFP(-4.500) 88.997 105 16-5% Spr(-15.482) 15.482 22.03 101 8-6 Spr(-12.755) 12.755 20.00 102 8-6 Spr(-13.248) 13.248 20.38 111 8-6 Spr(-41.389) 41.389 36.03 103 10-0 Spr(-14.600) 14.600 21.40 106 7-6%2 Spr(-16.117) 16.117 22.48 104 11-6 Spr(-14.912) 14.912 21.63 112 8-6 Spr(-41.783) 41.783 36.20 107 9-0 Spr(-17.942) 17.942 23.72 108 10-0 Spr(-18.015) 18.015 23.77 109 8-6 Spr(-20.613) 20.613 1 25.42 113 8-6 Spr(-43.203) 43.203 36.81 110 10-0 Spr(-27.444) 27.444 29.34 1 -4-0 S 93.264 339.21 , © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11: 27:08A M Page 3 Job Number: KS0354 Report Description: Ordinary Group 11 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Eq. Length Total Length Pressure Summary Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings aaw Route 1 DR 1.049 0=20.00 7.42 C=120 0.130131 36-11% Pf 5.070 101 8-6 q=20.00 K=5.6 12.755 Spr(-12.755) 2-0 Pe -2.585 14 14-6 15.241 E(2-0) 38-11% Pv AO 1.049 Q=40.38 14.99 C=120 0.477463 0-7'/2 Pf 2.678 14 14-6 15.241 5-0 Pe 15 14-6 17.919 P0(5-0) 5-7/2 Pv BL 1.610 0=62.42 9.84 C=120 0.132656 2-8 Pf 0.354 15 14-6 17.919 Pe 18 14-6 18.273 2-8 Pv BL 1.610 0=83.81 13.21 C=120 0.228851 4-6 Pf 1.027 18 14-6 18.273 Pe 33 14-6 19.300 4-6 Pv BL 1.610 0=106.30 16.75 C=120 0.355197 1-91'2 Pf 0.638 33 14-6 19.300 Pe 21 14-6 19.939 1-9/z Pv BL 1.610 Q=127.92 20.16 C=120 0.500330 5-2/2 Pf 2.603 21 14-6 19.939 Pe 25 14-6 22.542 5-2/: Pv BL 1.610 Q=151.64 23.90 C=120 0.685374 0-6 Pf 0.349 25 146 22.542 Pe 26 146 22.891 0-6 Pv BL 1.610 0=175.41 27.64 C=120 0.897253 4-6% Pf 4.072 26 14-6 22.891 Pe 29 14-6 26.963 4-6% Pv BL 1.610 Q=200.84 31.65 C=120 1.152565 7-5/z Pf 8.600 29 14-6 26.963 Pe 32 14-6 35.563 7-5/: Pv BL 1.610 0=230.17 36.27 C=120 1.483233 11-0 Pf 28.178 32 14-6 35.563 8-0 Pe 0.000 137 14-6 63.742 P0(8-0) 19-0 Pv CM 4.260 0=230.17 5.18 C=120 0.012979 11-5 Pf 0.148 137 14-6 63.742 Pe -0.000 138 14-6 63.890 11-5 Pv CM 4.260 Q=339.21 7.64 C=120 0.026594 419-0'/z Pf 16.703 138 14-6 63.890 209-0/: Pe 5.448 282 1-11 86.041 11 fE(8-11'/2), 2P0(26-4), 628-1 Pv 2fEE(4-5/:), 2Ee2(5-3), fE(6-9/, CV(28-11 /Z), GV(2-7%2) FM 8.329 0=339.21 2.00 C=120 0.001016 21-10 Pf 0.055 282 1-11 86.041 32-0 Pe -0.000 272 1-11 86.096 2fE(16-0) 53-10 Pv MS 10.020 0=339.21 1.38 C=120 0.000413 20-2 Pf 4.536 272 1-11 86.096 67-0 Pe -1.635 312 5-8 88.997 3LtE(16-0), BV(19-0), BFP(-4.500) 87-2 Pv UG 10.400 0=339.21 1.28 C=140 0.000259 113-1 Pf 0.067 312 5-8 88.997 146-8 Pe 4.200 1 -4-0 93.264 3LtE(25-6), E(35-1), 2EE(17-6'V), S 259-9%z Pv so Route 2 DR 1.049 0=20.38 7.57 C=120 0.134776 28-1114 Pf 4.577 102 8-6 q=20.38 K=5.6 13.248 Spr(-13.248) 5-0 Pe -2.585 14 14-6 15.241 T(5-0) 33-11% Pv es Route 3 DR 1.049 0=21.40 7.94 C=120 0.147449 31-0'14 Pf 5.607 103 10-0 q=21.40 K=5.6 14.600 Spr(-14.600) 7-0 Pe -1.934 18 14-6 18.273 E(2-0), PO(5-0) 38-0'h Pv Route 4 DR 1.049 Q=21.63 8.03 C=120 0.150368 34-11% Pf 6.310 104 11-6 q=21.63 K=5.6 14.912 Spr(-14.912) 7-0 Pe -1.284 21 14-6 19.939 E(2-0), P0(5-0) 41-11% Pv car Route 5 SP 1.049 0=22.03 8.18 C=120 0.155675 5-9 Pf 1.517 105 16-5% q=22.03 K=5.6 15.482 Spr(-15A82) 4-0 Pe 0.865 12 14-6 17.865 2E(2-0) 9-9 Pv BL 1.610 0=22.03 3.47 C=120 0.019327 2-914 Pf 0.054 12 14-6 17.865 Pe 15 14-6 17.919 2-914 Pv car Route 6 DR 1.049 0=22.48 8.35 C=120 0.161569 31-41/2 Pf 6.202 106 7-6% q=22.48 K=5.6 16.117 Spr(-16.117) 7-0 Pe -3.018 33 14-6 19.300 E(2-0), PO(5-0) 38-4% Pv cio Route 7 (by ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11:27:09A M Page 4 Job Number: KS0354 Report Description: Ordinary Group II Diameter Flow Velocity HWC Friction Loss Pipe Type Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream DR Length Eq. Length Total Length Pressure Summary 1.049 Q=23.72 8.81 C=120 0.178426 107 9-0 q=23.72 K=5.6 17.942 Spr(-17.942) 25 14-6 22.542 E(2-0), PO(5-0) 32-0'% 7-0 39-0'/z Pf 6.968 Pe -2.368 Pv 06 Route 8 DR 1.049 Q=23.77 8.82 C=120 0.179094 108 10-0 q=23.77 K=5.6 18.015 Spr(-18.015) 26 14-6 22.891 E(2-0), PO(5-0) 31-0'/z 7-0 38-0'/z Pf 6.811 Pe -1.934 Pv 611, Route 9 DR 1.049 Q=25.42 9.44 C=120 0.202861 109 8-6 q=25.42 K=5.6 20.613 Spr(-20.613) 29 14-6 26.963 E(2-0), PO(5-0) 37-01/2 7-0 44-01/2 Pf 8.935 Pe -2.585 Pv Route 10 DR 1.049 Q=29.34 10.89 C=120 0.264359 110 10-0 q=29.34 K=5.6 27.444 Spr(-27.444) 32 14-6 35.563 E(2-0), P0(5-0) 31-01/2 7-0 38-01/2 Pf 10.054 Pe -1.934 Pv Oar Route 11 DR 1.049 Q=36.03 13.37 C=120 0.386581 111 8-6 q=36.03 K=5.6 41.389 Spr(-41.389) 16 14-6 53.349 E(2-0), PO(5-0) 30-7'/z 7-0 37-7'/z Pf 14.545 Pe -2.585 Pv BL 1.610 Q=36.03 5.68 C=120 0.047993 16 14-6 22 14-6 53.349 53.871 10-10'% 10-10'/z Pf 0.523 Pe Pv BL 1.610 Q=72.23 11.38 C=120 0.173775 22 14-6 30 14-6 53.871 55.748 10-9'/z 10-9%z Pf 1.877 Pe Pv BL 1.610 Q=109.03 17.18 C=120 0.372305 30 14-6 138 14-6 55.748 63.890 PO(8-0) 13-10'/z 8-0 21-101/2 Pf 8.142 Pe Pv s� Route 12 DR 1.049 Q=36.20 13.44 C=120 0.389989 112 8-6 q=36.20 K=5.6 41.783 Spr(-41.783) 53.871 E(2-0), PO(5-0) 22 14-6 30-7'h 7-0 37-7%z Pf 14.673 Pe -2.585 Pv (sip Route 13 DR 1.049 Q=36.81 13.66 C=120 0.402231 113 8-6 30 14-6 q=36.81 K=5.6 43.203 55.748 Spr(-43.203) E(2-0), PO(5-0) 30-7%z 7-0 37-7%z Pf 15.130 Pe -2.585 Pv frg iva[e pe l e tl § at '' v. s 12}oi) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter 1 4 87 /1 = Factor 1 Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11: 27:09A M Page 5 Job Number: KS0354 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings Length Eq. Length Total Length Pressure Summary tp9S`i:;� AO BL CM DN DR DY FM FR MS OR RN SP ST UG Arm -Over Branch Line Cross Main Drain Drop Dynamic Feed Main Feed Riser Miscellaneous Outrigger Riser Nipple Sprig Stand Pipe Underground Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV AngV b BaIV BFP BV C cplg Cr CV DeIV DPV E EE Eel Ee2 FDC fE fEE flg FN rr g GIoV GV Hose HV Hyd LtE mecT Noz P1 P2 PIV PO PrV PRV red S sCV Spr St T Tr U WirF WMV z Alarm Valve Angle Valve Bushing Ball Valve Backflow Preventer Butterfly Valve Cross Flow Turn 90° Coupling Cross Run Check Valve Deluge Valve Dry Pipe Valve 90° Elbow 45° Elbow 11%° Elbow 22'/:° Elbow Flow Device Fire Department Connection 90° FireLock(TM) Elbow 45° FireLock(TM) Elbow Flange Floating Node FireLock(TM) Tee Gauge Globe Valve Gate Valve Hose Hose Valve Hydrant Long Turn Elbow Mechanical Tee Nozzle Pump In Pump Out Post Indicating Valve Pipe Outlet Pressure Relief Valve Pressure Reducing Valve Reducer/Adapter Supply Swing Check Valve Sprinkler Strainer Tee Flow Turn 900 Tee Run Union Wirsbo Water Meter Valve Cap 1 © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11:27:09A M Page 6 Job Number: KS0354 Report Description: Ordinary Group II Supply at Node 1 Pressure, psi , , „ 1 , 1 , , I , „ I I „ , I l l i l , , , , , , 11 , , 1 „ , 1 , 1 1 , 1 , , , 1 „ I , I I I „ I I i „ i , , I I I b , , , , 1 1 , 1 1 , 1 , 1 , , , , , 1 „ i , , , , , , 1 Static Pressure 140.000 .589.2 339.21 with hose @ 93.264 streams System demand curve 10900.00 @ 20.000, 1 11111111 I 11 1111 11 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111111111 L L 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V pU1.11111))II i1oo22M 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hydraulic Graph Supply at Node 1 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.457 @ 589.21 System Demand 339.21 @ 93.264 System Demand (Including Hose Allowance) 589.21 @ 93.264 [y ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11:27:10A M Page 7 Job Number: KS0354 Report Description: Ordinary Group II © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.2.6 04/29/2008 11:27:11 AM Page 8 1 V T s IL DDITI ON AR SHEET NUMBER SHEET TITLE FA -01 SYSTEM INFORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SINGLE LINE DIAGRAM FA -04 FIRE ALARM SYSTEM PLAN SHEET INDEX 16 Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject ro errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions ; revisions to these drawings after this date will void this <cceptance and w l require a resubmittal of reviseo drawings for subsequent approval. Final acceptance is subject to fleld test ano Inspection by The Tukwila Fire Prevention Bureau. Date: LI,).,o'1ii By: 511 WI QVILS. FIRE. DEPA4: IEP'T eaW� CAI 206-575-M7 •'!VC: t tiS Fix; ; I' ei 1.t No. 0 -:d address for shut .aUwn or reStoration approval, SCHEDULE A\ D COI\ D U IT FILL CHAT SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 1 E E E 2 E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 8 FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2 EXTN CEILING ®E D DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM E DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS EXISTING VERIFY IN FIELD HT -R INTERFACE MODULE E WITH RELAY (EXISTING) HTRI-R SIEMENS EXISTING VERIFY IN FIELD FIRE ALARM STROBE (EXISTING) ZR -MC -W SIEMENS EXISTING CEILING FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -W SIEMENS EXISTING 80" A.F.F. TO BOTTOM 8E FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING DE TENANT J -BOX (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 1 • ORGANIC NAIL BAR 426 / SPACE #1000 SSS T F 5' + WIRE DESIGNATION GENERAL NOTES i = """""" 10B NUMBER: 31724-1 J �.. SHEET FA -0-1 u Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ../(� PAID APR 1.1 2 15 LIKWI LA FIR=-. z 0 z_ w Q w 6 V J N) FAX (206) 628-[.990 RELEASE/REVISIONS REV. BY: I WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 1 E E E 2 E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 8 FIRE ALARM SPEAKER STROBE (NEW) SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2 EXTN CEILING ®E D DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM E DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS EXISTING VERIFY IN FIELD HT -R INTERFACE MODULE E WITH RELAY (EXISTING) HTRI-R SIEMENS EXISTING VERIFY IN FIELD FIRE ALARM STROBE (EXISTING) ZR -MC -W SIEMENS EXISTING CEILING FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -W SIEMENS EXISTING 80" A.F.F. TO BOTTOM 8E FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING DE TENANT J -BOX (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 1 • ORGANIC NAIL BAR 426 / SPACE #1000 SSS T F 5' + WIRE DESIGNATION GENERAL NOTES i = """""" 10B NUMBER: 31724-1 J �.. SHEET FA -0-1 u Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ../(� PAID APR 1.1 2 15 LIKWI LA FIR=-. z 0 z_ w Q w 6 V J N) FAX (206) 628-[.990 RELEASE/REVISIONS REV. BY: I 0 DESCRIPTION SHOP DRAWINGS DATE 03/26/18 2 aaaaa 0 _ CC z o _• 0 Lu T Ct.O E0 cLz w 0 ® < 4- • 2 J C'3 Z (yW dz o u) w ¢ Z `__ CC Ili I- Q Ll. oH t4 (CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 03/26/18 BACKROUND PLAN PROVIDED BY: SITE PLAN Cc zov THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. PUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ TUBE OUTLET SAMPLING TUBE INLET__. SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL DEDICATED EMERGENCY , FROM EXISTING MAIN FACP C CABLE C' CABLE 0 aj „Diu GRD N L 0 PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 B m 1 & 0 0 0 (-) (+) (-) (+) HARD LID CEILING HARD LID —\ SPEAKER SUPPORT TILE BRIDGE NAC S4 2, NAC S3 NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) (+(-) STROBE SPEAKER (+) FROM PREVIOUS ADDRESSABLE 2 DEVICE TB1 0000TQ0 00 NO COM NC EOLR 470 0 TO FAN SHUTDOWN + eTONEXT e ADDRESSABLE DEVICE 0 2 3 4 O O e HTRI-R r - 0 NO 6 COM B NC ® TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (+) ( ) STROBE SPEAKER (+) (-) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 RELEASE/REVISIONS IREV. BY: SWITCH + - INPUT LED TSM -1 0 TO FAN SHUTDOWN + eTONEXT e ADDRESSABLE DEVICE 0 2 3 4 O O e HTRI-R r - 0 NO 6 COM B NC ® TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) ( ) STROBE (+) ( ) STROBE SPEAKER (+) (-) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 RELEASE/REVISIONS IREV. BY: DMG DESCRIPTION [SHOP DRAWINGS UJ I- < 1 03/26/18 aaa<a Cif) 74Z w 0 z o T 00 cr z co < 0 w F-- 1-= Orn 0CLz ci) o O dCz w�z 2 z� r� <tU� 111 O uoH CV 3 4-CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 03/26/ 18 BACKROUND PLAN PROVIDED BY: �OB NUMBER: 31724-1} SHEET FA -02 Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps A B C D E F G H 1 J K FIRE ALARM BOOSTER Project: ORGANIC NAIL BAR Panel: EXISTING BPS PAD -3 Date: March 26, 2018 Module/Device POWER REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 725 2 aaaaa Total(A)= 15 Total(B)= 865 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 865 Total current ratings converted to amperes (line D x .001) 0.015 0.865 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.0720545 Add lines G and I Total Standby and Alarm AH 0.4320545 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.5184654 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 CALCULATIONS Notification Appliance CircuitDetai PROJECT: ORGANIC NAIL BAR Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLE Date: March 26, 2018 Wire Resistance 2.58 CURRENT TOTAL= 725.00 1 SET -MC -CW @l5cd 1 SET -MC -W @15cd SET -MC -CW @75cd 2 SET -MC -CW @95cd 1 ZR -MC -W @ 15cd DEVICES 5 TOTAL Total Wire Resistance (R ) Total Device Load, Amps (I) Voltage Drop (E ) EOL Voltage 69 64 200 264 64 A= 69 64 0 528 64 725 14 289 22.92 725 ( WL *2 )* (Rift) (Total Cct Load) (E=I*R) 24 - E) 1.49 0.73 1.08 22.92 TO EXISTING POWER SUPPLY TO EXISTING SPEAKER CIRCUIT TO EXISTING DATA LOOP S,V S1-1 15Cd S1-2 15Cd S1-3 15Cd S1-4 S1-5 95Cd 95Cd EOL S1 D,I 21� ITSMIE SINGLE LINE DIAGRAM E FLAG NOTES: EXISTING RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. Eft 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622--6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE co N M O 2 aaaaa I� z co E E2 w U 65 0 cc Lcic-i Oi �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 03/26/ 18 BACKROUND PLAN PROVIDED BY: \0B NUMBER:31724-1} SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved TO TENANT JUNCTION BOX S,V --o S,v- 8 S1-4 95cd S1-5 95Cd S S,v FIRE ALARM SYSTEM PLAN FLAG NOTES: EXISTING RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. FAX (206) 628-4990 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 03/26/18 2 aaa<.a " �1 0 0 0 T CC 4f -; Q r Uc0 0 z l 0 0) 0 Z W Qz 0) W Q z cLO CC WFC © LiOH cn N of) >4, (I) CC LL �CALE:1 /4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 03/26/18 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 31724-1} SHEET FA -04 Pro rieta and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved r q Of It EXIT EXIST NG 2'x2'. CEILING TILE 10®" l F F X_ 0__ "dXISTINI CEILING 11'-10"A 2'x2' TILE F DRY WALL CEILING 11'-4" A F F REFLECTED CEILING PLAN SCALE: 1/4"=1'-0" QI Design per NFPA 13 — Ordinary Hazard Group 2 — Light Hazard All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions Ac_ a4A Wiiheut Comments ❑ As Noteo h Re ❑ Per The Attecn tetter These plans have heel reviewee t The T ukwlla Fire Pr3ventton Bureau for conformancE 1, tp current City Acceptance is si.ib ec* to &Tors ar'd c tiv�- oris which Cr' r or a>>trtorl<e violations cf adopted loaras ar _C? o _ ; Pisces Tne i espC:"s'b' 'ty for the d�..>.t; Of oe sg . e totall"i with tr a�y A Itrt rs, , e.e tiO ;5 ; e =Islons to tree erawings after til:: Gad ori t void tr.sacceptance atid at"t' reouire a resubrnittai of r:-:.visec. e.rawir as for slucy-equr't approval. Final ac: eptance is suo)ect to Heid test and inspection:by The Tukwila Fire Prevention Bureau. Date: CI _3 -18 By: rFlexHead Sprinkler Drop Corrugated stainless steel hose with stainless steel bre available in 2', 3',4',5' & 6' Iegnths Adjustable Hub Multi -Port Bracket • 1 — Add Reliable Model G5-56 Quick Response Concealed Pendent 1/2 x • E — Existing no change i-LFEA3 71 tI 1IR IES ," Flexheadtommercial Ceiling Unit T -Bar Ceiling Installation Model t# 2024,2036,2048,2060,2072 r ORGANIC NAIL BAR 426 Southcenter Mall, Tukwila, WA 98188 ilol uioR1 i = _i at hili ...... .,r,. r�� apt■ n � Jlryp )i ' ! �,.. ORGANIC NAILS BAR KEY PLAN ..niefferucmi, FIRS PROTUCT1014 YPRN+KUGe SYSTEMS John J. Abel 9700 -0681 -CG Level3 Crown Fire Pietection, man ,a 0, ix s,..•!.14 w.yr >�' P . •o.• NCY I- Fl"2.1i UTtiC.7':c1At 5.Yrtiwhit iw rivarruo Jnh rw 0 A' 41v ?/8C, -0591-C'0 !vv. ' Crc 'r I :rn i .t31.,6 -ri, tiro. CPC vit!Ekte ,..L _ - , at TWA..al0 • • CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 ORGANIC NAIL BAR 426 Southcenter Mall, Space #1000 Tukwila, WA 98188 PALO HA :1 2e!L 'U LA F1,q E -7/---/M(7 DATE: 3. l DRAWN: SCALE: I / 6 t / rt 2 FI E S ST M TUKWIL SHINGTON SHEET INDEX GENERAL NOTES SYMBOLS .LEGEND SHEET \UVSHEET TITLE SYSTEv TYPICAL I\FOMATIO\ DETAILS - WRING A\D MOUNTING FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE IINITIATING DEVICES UNTIL PREPGRAMMED .WITH DEVICES 'ADDRESS. QUANTITY SYMBOL DESCRIPTION FACP FRE ALARM SYSTEV FL00H PLAN SYSTEM CALCULATIO\S 1. NUMBERS . ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND 'DEVICE ON ADDRESSABLE LOOP 1. .I 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH.. THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL 'CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E.., CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD. BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. GE\ EAL), �ISE� SITE PLA\ VOlhout•y ❑As Nc'.` ❑ Per (i •I"4'.C.4iii:.%�: ..4. ,.t i nese piens I,�' �';. I ..JI: i • ;4:,0b Fire Prevention I:;;tr,: ,:; t w;IJi cur( t ntcity standards. , : r rc r...rd omissions ef adopted star da; ,: .. ; , ir. , . i ' ,i.. r.' 'tOr the adequacy o..+.. Additions, 0 I: ass: _ i,::<<: st3 c:Z,v.;r;gs ;atter this data Will 1 t1!: ti f... JE:... : .Ci Ci titt e rt-4LC,:e resubmittal of or,,,..v ng;s tor subsequent approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presentaP. to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. Final acceptance is sr.tb ect to field test and inspection by The Tukwila Fife Prevention Bureau. Date: S- 0 By:AVv\511 :.UKWILA FIRE DEPARTMi 1 call: 575-440Z nd give this job art.i oxact address for shut 1 r.,., an or restoration approval/' WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CO\DUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD 4#12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD *16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR 4#14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED 4418 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAVI OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SI IALL DE MOUNTED AT 48" A.F.F. TO TI IC ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED 2 2 2 EX BPS FIRE ALARM REMOTE ANNUNCIATOR REMOTE BOOSTER EX POWER SUPPLY SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP. CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD F -13 -‹LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD IA SMOKE DETECTOR HFP-11 W/ SIEMENS V�1 (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE AD DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING Ec FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. Ec FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM SPEAKER STROBE (CEILING MOUNT) SET -MC -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM SET -HMC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. n c FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING L FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX IN/ 1-1/2" EXT. CEILING Q FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM TIO WP FIRE ALARM STROBE (WEATHERPROOF) SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.❑. F,B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U,❑.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAO t",4.; 15 2008 COAA- �kwil41f��rC 2- t Copyright 2006 by Guardian Security Systems,Inc. All Rights Reserved RELEASE/REV m LIJ cr DESCRIPTION z Q SHOP DRAWINGS Lu a 0 N 0 0 z (SCALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: �OB NUMBER:54557 } THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL DR PREVIOUS ADDRESSABLE DEVIC END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH 0 DUCT DETECTOR LDCATI❑N GROUND 0 0 0 r� 0 0 0 HTRI-R 01 STATUS LED Oo 0 N.O. 0 0 1 COM N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL 0 LABEL SCALE (BACKGOUND MUSIC SHUTDOWN) PREVIOUS ADDRESSABLE_ DEVICE TO NEXT ADDRESSABLE r DEVICE L + NOTE 1: VOLTAGE MAX, - CURRENT MAX: - CONT: RES. MAX. - MAX, CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN, LINE SIZE- OUTLET SAMPLING ', TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE=NONE MUSIC 11 -AC POWER SOURCE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING 0 TO NEXT ADDRESSABLE DEVICE f(+) ik STOP IF LAST DEVICE O FROM XLS CONTROL PANEL OR''' PREVIOUS ADDRESSABLE DEVIC{(+) (-) RELAY CONTACTS (4.OA @ 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 rnA DURING POLLING 10 OHMS 200 FT. (18 AWG) (102uF 0,D4uF 14 AWG 18 AWG NOTE 21 ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST 25 SEC, TO GUARANTEE DETECTI❑N, 1001 TB1 00 00 123456 HC TB2 ma{46�0� 654321 0 /2 END ❑F;'LINE DEVICE (3.6K 1/4W) SUPERVISED 1 SWITCH GROUND 0 0 0 HTRI-D STATUS LED CO 0 r-- 0 1 1 NOT USEDi ' CO 0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC 0 0 _L J_ L TT' 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+. 1- 1 2+ 2- 2 NC C NO + + - + - + - + - 0 0 0 0 1-g- _2_ 24K g- 24K + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE NAC -4 NAC -3 2 NAC -2 NAC -1 END DF L.IN,E: DEVICE 316K 1./4W) s UPERVISED &WIT:CN , FRONT VIEW 1 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP 0 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE POWER SUPPLY C'S' CABLE) FROM FACP (VOICE CIRCUIT) ('V' CABLE) 470. OHMS EOL TS M-1 0 O 0 1111 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE C ., (S ) STROBE SPEAKER () STR❑BE-) EARTH'.-, GROUND -›-(+) TO NEXT DEVICE OR l —�(-) STOP IF LASTDEVICE (+) (-) STROBE SPEAKER (+) (-) SPEAKERISTROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE ---...... OR STROBE ONLY F R 0 SPEAKER/STROBE 4S DEEP BOX w/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE=NONE j' TO NEXT J' DEVICE OR END OF LINE TO NEXT DEVICE OR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TING TEMPERATU E: +32•F (O' C) TO 100' F (38' C) HUMIDITY: UU0-933% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE r DATA IN (-) > it DATA IN (+) > DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD r SMOKE DETECTOR: BASE TO NEXT DEVICE*— REAR VIEW > (-) DATA OUT > (+) DATA OUT HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID ---- CEILING SPEAKER SUPPORT T . E: BRIDGE HARD LID 4' SQUARE DEEP BOX' WITH 1-1/2' EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALE=NONE JUNCTION BOX MOUNTED ON \ CEILINGI FLEX \ / / / / JUNCTION BOX / MOUNTED AGAINST / CEILING SUPPORT iI / T❑ NEXT DEVICE ' 0 O CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING DO NOT NSTALL ADDRESSAB_= ILII- A DEVC=S UNTO PREPROGRMM-D WITI- DEV C=S DDRESS. N G oe • z• N C)I•X L1_ LU Q W (.) 10 q) N ui N > Q ►- O • Cn N• • W RELEASE/REVISIONS CO w z DESCRIPTION SHOP DRAWINGS I- Q DRAWN BY: (:ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: II. �OB NUMBER:54557 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved.- 0' • 1) (B.7) f I IT i JO. • v. 1' ' / L ' ..... ..... ,I!----,, 4 2S, /' _.,:-•--,!:' .-- •‘,.--.1 \:0E 2S 2S,2V , • 75 JPAAA,2,1111.11,11,11.1—,1,1,1W1A,M17.1,17: 15 R. M C.1.119. -1) 11 ...... - .3 ...... ..... AnT.7. El CASI1MAP •,/ f ( ':- ix • jES1AURAN I3I1,WLATION Room ( D ) ....... - 15 7,4 1..CANGF. • I UNDS HEARING WESTFIELD SOUTHCENTER MALL ! t • . • TAG NOT 444 [8> FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITS.(SEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY ESS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR, SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLATDR FIRE SUPPRESION SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL, FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. , DO NO I\S LL ADDRESSABLE \H I DEV CES PREPROGRAMMED W DEVICES ADDRESS. AT Copyright 2006 by Guardian Security Systems, Inc. All Rights ReservedH z uJ uJ uj 1743 1ST AVE. UJ DRAWN BY: I.ANDERSON DESIGNED BY: R.VEZZANI DATE:5/12/08 BACKROUND PLAN PROVIDED BY: 1..0B NUMBER:54557 SHEET z < . ; . DESCRIPTION SHOP DRAWINGS al ‹1— m 5/12/08 UJ DRAWN BY: I.ANDERSON DESIGNED BY: R.VEZZANI DATE:5/12/08 BACKROUND PLAN PROVIDED BY: 1..0B NUMBER:54557 SHEET a., I ID 02 RS R !E \ S•I ION D/`; D CL) Lii< L VLF.' WIIEESS ELEC I'v1 ADE IN WA 21-1I 02; FON 28.50. Firii31-1 Floor E',E.'voision THREE I i•-:`,/E1..S 1 7,(1.,‘,3 NORTH [ TRASH -'&," ------ -•, LLJ 1.1.J LLi MALL PETZI TR ------ L MALL ZOUNDS HEARING •-• •. ) '1010 15001 ...... IfL Trli. ET LNI 1550 H1020 FQ, • LE -j 10 0] ID] 154-5 L ; ' ',SEATTLE 1\,1t-s,RINER`:_; 7-11/2\1\A pAD01C., SUN] VVE THE VV4,,1.V NJ L 1 100 bebe 111 •Lry,- ---- -- if) - ZOUNDS HEARING WESTFIELD SOUTHCENTER MALL ---------------- m • • ft 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V 2S,2V orr C 110 75 15 15 15 15 15 15 30 EOL -S1 30 2S,2V-(=> FA BOX FACP EX D TS DI 21 SYSTEM CALCULATIONS • : ! 11 ZOUNDS HEARING . . „ , ,.. . , „ -, , , , : . , . , '•'':11---:1 I'l: : CURRENT TOTAL= , ZOUNDS HEARING H . - , ZOUNDS HEARING SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations ! . • . FACP ADD ONS , , . •- <<<< QTY. Device Type Alarm Current : , _..._ VVire Length Voltage at EOL Circuit Total , Current Load : r 64 0 :, ' Standby:, : Alarm: Current Load: 0.86 SET -MC @3OCD. Standby: Alarm: .: , •: , ( WL *2 )* (R/ft) 1 0 SET -MC @75CD 175 175 : Total Device Load, Amps (I) 0.99 SET -MC @110CD. DeVce Type 0 Qty Amps : : : 'Total Amps Total , . Device Type 318 Qty Amps Total ' Amps Total Voltage Drop ( E ) 0.85 0 , . , . •' . , ' . . , HEP -11 . 0.0022 0.0022 . 0.0023 0 Main System Board 1 0.03 , . . .. ,. 0.03y 0.030 ' 0.030 • „ 0 AD2-P , 1 0.0635 - 0.0635 0.064 0.064 . •I. SET4/IC @l5CD0.064 i 384 , 4-10 HTR -R • ; 98 2 0.009600. 0.0096 0.021 0.042 ' 1SET-MC @30CD 2 , 11233 . , , 0.098 0.196 • ___ HTRI-D . ----7- 0.001600 10 : 0.0035 988 12 SETi-IVIC 75CD 1' 1 • ---------- . , • . ' . ', , 0.175 0.233 0.175 0.233 i. ,'. ICP -B6 ,: Detail 0.005 SET4/10 0CD 10 WESTFIELD SOUTHCENTER MALL , . . , 1!, SET-C@115CD SETiIHM-CC@135CD • Panel: ZOUNDS HEARING' , : - , Wire Resistance 28 •i ::, l' 0.318 Date: May 13, 2008 . CURRENT TOTAL= 7.2 CIRCUIT: SPEAKER CIRCUIT . .. , . 0.318 i • . . . .. . 1 :: " . • , • •-• ., QTY ...,.,:. : Device Type ... ..: • 'Alarm' Current . 1 1' SET.HMC-C@185CD , .__ ,..._ _ Voltage at EOL Circuit Total • ...„...... 0.445 1 . 70.7V 1/8 1:8 7.2 . 0.0731 Amps 0.106 Amps: ZR -MC @'.15CD 0 6 0 • , 0.064 0.384 : 1; " „ . r , r r , • 1 0 ZR -MC WOCD . Total Device Load,Amps (I) 0.01 0.098 ' 0 : Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours . HCP; ' , 0.0015 Voltage Drop ( E ) 0.02 0 .1' . ' 1 '• „ , 0.03 Amps 1.018 Amps ' : Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours -1.1; 0 • 0 0 0 - T , . Standby Current Load: 0.03 Amps For:24 Hours = 0.720 Amp -hours TOTAL mA= 7.2 ,, . 20.37900912 7.21 25% Derating= 2.204 Amp -hours .• :,! '1;.' : 1J • 1! Alarrn,COrtent Load: 1.018 Amps For -5 Minutes= 0.086 Amp -hours . „ , Total System Current Load: 2.204 Amp -hours . ' 11 25% Derating= 1.007 Amp -hours j i H • Battery Pair to be Used: 12VDC Amp -hours 7AH 1, . . Total System Current Load: 1.007 Amp -hours , . . , 112VDC _ Battery pair to be Used: Amp -hours 7AH . .'; BATTERY SIZING CALCULATION Panel: ZOUNDS HEARING , - - - . , . , . 'Wire Resistance 'I'A ' . - 7 _ ---- - ---- - ----- - Date: May 14,2008 : CURRENT TOTAL= , 988 - _________ ciRcUit. si . • . , , . •- <<<< QTY. Device Type Alarm Current Alarm Total Wire Size _..._ VVire Length Voltage at EOL Circuit Total 0 2 SET -MC @15CD 64 0 . ,_____ Total Wire Resistance ( R ) 0.86 SET -MC @3OCD. 98 196 _.. _ ( WL *2 )* (R/ft) 1 0 SET -MC @75CD 175 175 Total Device Load, Amps (I) 0.99 SET -MC @110CD. 233 0 : (Total Cct Load) 0 SET-HMC-C@115CD 318 0 Voltage Drop ( E ) 0.85 0 SET-HMC-C@177CD 445 0 . . , • (E= 1 * R) 0 SET -HMC @135CD 318 0 EOL Voltage 19.55 0 . 6 SET -HMC @185CD 445 „ 0 (20.4 - E) Z-MC@15CD 64 i 384 4-10 Z-Mb@a0CD . • ; 98 , . ; 0 ' ' ; ,SET-MC-CW@110CD. 11233 ' 233, • . ----7- DEVICE8= 10 : TOTAL m A= 988 12 7 265 7 19.55170321 988 • ---------- . : .'Notification - Appliance --------- Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL , . . Panel: ZOUNDS HEARING' , : - , Wire Resistance 28 Date: May 13, 2008 . CURRENT TOTAL= 7.2 CIRCUIT: SPEAKER CIRCUIT - -...J.L . . . .. .. . . . . . •.• , .• . . . .• • ..,. .. • • ......„......„....•.. . • , • •-• ., QTY ...,.,:. : Device Type ... ..: • 'Alarm' Current ... Al arm. Total Wire Size • Wire Length, , .__ ,..._ _ Voltage at EOL Circuit Total • ...„...... 4 70.7V 1/8 1:8 7.2 Total Wire Resistance ( R ) 2.92 0 0 0 ( WL * 2 )* (R/ft) 0. 0 _. Total Device Load,Amps (I) 0.01 ' 0 0_ (Total Cct Load) • 0 0 _____________________ Voltage Drop ( E ) 0.02 0 (E= I * R) O 0 0 0 - -0 , ' EOL Voltage (204 - E) . 20.38 0 • 0 0 0 - T , . DEVICES= 4 TOTAL mA= 7.2 1456 1,. 5 1,11;', 20.37900912 7.21 ,k„,•••• row* •]-11('" ONS REV. -BY: I NVI DESCRIPTION SHOP DRAWINGS W I - <t D 5/12/08 < <<<< co CO _J R; Z CC LT1 2 6 < LCE W `21 1.± ocn (I) i< o < 15 D a-. ,„ O ilJ IL ; SCALE:11,18 =1 DRAWN BY: I.ANDERSON DESIGNED BY: R.VEZZANI DATE:5/12/08 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM VOLTAGE DROP CALCULATION \z1.0B NUMBER:54557 ,Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved - - _ SHEET Zounds w N VICINITY MAP (Suite# 426) SCALE: NTS General Notes 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. ZONE T-2 a 0 c-FFL^= rttr 1- 4= Without Cornments AS Noted In Red Per Thtz, cl.<_;Letter mese plans • Prevention standards. omissions starraaras an adequacy of ., Additions, (� . 1 1 Fire :city ,doptcd i, fort;t d...:'Ini'i. �.. �i'i+;i: lir lt'iillji' uticir this date 'viii - - ,c;<_: ,l l,,fill rt_:.qtilro o I resubmittal o; s:: --±;;, a:. i4 v -:j lot vut;sequl nt i ipprovr 1, ; Final acceptance it :ziti'itot to field test t4nd inspoctioon by The Tukwila Fie Prevention Bureau. ( C Weld stamps must be inspected before pipe is hung. Do nQt paint piping prior to hydrostatic test approval. TUKWILA FIRE DEPARTMEN1 Please call: 575.4407 and give this job/ No. o S -S —/ and exact address for shut' /own or restoration approval, WEST RISER DETAII HYDRAULIC REFERENCE ONLY NOT TO SCALE EGRESS CORRIDOR FlM91E0CEueiG'rEl(i<T r5•-0•AF F. \ I TOILET ROOM .`_GYP. P.D. CELLO TB APF WITH PIATFORII c :i41` OFFICE rag sG•E0 CEL0MDGHT 5'0'AFf. BREAKROOM FINISIE0031P43 i-EGHT Ordinary Group Il•r,.20gpmlft2 for 948.00ft2 TEL/DATA CLOSET CPU,' TO OEGC CONSULTATION F CUSI "e O CEILING IE°HT S yeAFF. LLL AUDIOMETRIC EXAM f- AFf. AUDIOMETRIC EXAM FiNIf.,4E0 CEILING HEIGHT., .6.: dB Al• AUDIOMETRIC EXAM FWSi&OCEANG HEIGHT b-,• if -6" AFF. SALES AREA FINWE0 CFILFrcGiSJGFR 1 ��otuF. DEMO ROOM .1„6-, FIN44E) GERIGItEGHT �. 10t AFS. \Jr SOFFIT :B i F01i4'FDCEel-CG HEIGHT `ILL IOt AFF. 11-10 ]WAFT. ,e, zt F08SIiEDC0UN0Hmrt 1-- 5-1PAFf. SOFFIT 1 F92SHE0 CEIl+TG HEIQ4T Pt ALF. �.lL'-� A =' ,-1-(`;.P• .l/:f SOFFIT FI4t9<EDCEIL1,4 IEciT0 J 9,10. AFF. L lI RESTAURANT SIMULATION ROOM . FWIs#D GEAIGHEIGHT t0 -P AFF. SOFFIT F00aC2,CELUGtfIGHT • SOFFIT FleiSSNEJ CVONO HEGHC-e.71 10-41. AFS. •I SALES AREA Flws1E0cEILu4G FBGHT=� 1f 1•AFF. FIRE SPRINKLER SYSTEM -17 AFT TYPICAL FLEXABLE SPRINKLER CONNECTION. FLEXHEAD MOUNTING BRACKET PIPE NIPPLE SPRINKLER BRANCHLINE.. FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID SPRINKLER HEAD CEILING TILE FLEXHEAD DETAIL NOT TO SCALE //////////////j/_T E gigue F10.909 SWIVEL SWAY BRACE FITTING 132,61 BRACE PIPE FIG.1000 "FAST CLAMP' SWAY BRACEATTACKMENT LINE PIPE LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE Zounds Remote Area: Retail # 426 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY cuss ORD HAZARD II MAX. COVERAGE per HEAD 130 ' DENSITY .20 GPM r Ft' for 948 Fe F SPRINKLER Reliable Model G4A ORIFICE 1/2" K= 5.6 WATER FLOW INFORMATION': STATIC 140 PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER. SYSTEM REQUIRES: 339.21 GPM © 88.99 PSI At time of Design 11'-6" CLG.=37.75% AREA REDUCTION 3B- KWIK BOLT (2 IM• EMBED LENGTH) FIG.809 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT FIG.4A PIPE CLAMP FOR SWAY BRACE LATERAL BRANCHLINE RESTRAINT BRACE PIPE i i NQY-THREADED BRACE PIPE LATERAL BRANCHLIN NOT TO SCALE RESTRAINT Hanger No. 07C HILTI Kwik Bolt III Cut Rod Lgth Rounded to Nearest Inch // ` - / /'/ NMI Ka. Bak II Drilled Anchor i� // Rod Coupling Al Thread Rod Swivel Ring ‘1/4„ Concrete f Construction Bottom of Concrete to Center Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE .... 2008 446°0 Doges tvl Wa Fire Zs�77 4f/7,e- co c O N. • w 0 Adam Kantner d a) Marco Contractors 0 Q ce z 0 SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE N0. DESCRIPTION DATE SYM. SIN QTY. K SPRAY ORIF. FIN. TEMP. MFR./MODEL 4 -WAY EARTHQUAKE BRACE R5415 24 5.6 Pendent White 155°F G4A Concealed APPROVAL: City of Tukwila 0 HYDRAULIC REFERENCE POINT R3615 1 5.6 - Upright /II Chrome 155°F F1 FR Upright CONT. NO.: KS0354 Total = 25 DRAWN BY: Adam Kantner HANGER SYMBOL BRANCHLINE RES t NAINT SPRK ON SHEET: SEE LEGEND SPRK ON JOB: DATE 05/01/08 Western States Fire Protection Company 7102 180th AVE NE, Si t 4105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED IH ¢/AIISTYI/DALLAS/DECATUR/DENVER/DULUTH/HOLSTON/KANSAS CITY LAS VEGASfMWNEAPOLIS/PHOEN X/PORTWtD/RAPID CITY/ST. PAIR./SALT LAKE CITY/SEATTIE Phone: 425-881-0100 Fax 425-881-3030 Zounds 426 Southcentner Mall Tukwila ,Wa 98188 FIRE SPRINKLER SYSTEM SHEET FP -1 OF 1