Loading...
HomeMy WebLinkAboutPP - 436 SOUTHCENTER MALL - SELECT COMFORT - PERMITS AND PLANS436 SOUTHCENTER MALL ASSOCIATED PERMITS 17-F-170 08-F-175 17-S-169 17-S-168 08-S-165 4isittlav444 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address:_ . sootIvertier yn4I Suite Number: OM Floor: Tenant Name: K..\\04A j Ycsst * t New Tenant? ❑ - Yes ❑ - No +- 6rtp SITE LOCATION Property Owner's Name: W � -Q .. Mar Mailing Address: City CONTACT PERSON -if there are questions about the submittal. Name: GY IS -VW Company Name: State Zip Day Telephone: 142S '9 %1 "7(0(09 Govan \V - t ether V Mailing Address: U ` WI �1` l.._ Y X-1 \)N qRutz City State Zip Fax Number: E-mail Address: Total number of new/relocated devices or sprinkler heads: 7 Valuation of Project (contractor's bid price): $ 1 ,5Cxz)g:0 Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. _ I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Plan Permit App.doc Jess ica Date: ...30.17 Day Telephone: 1425 • '1 1) ' UV/ 1/2/13 TFD FP Form 8 441 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION King Co. Assessor's Tax No.:Ct 202141.00 I 0 Site Addre • : o ce v U 1.)NA aAtet Suite Number: Floor: Tenant Name: r I ka U1tS/l. Er s New Tenant? 0- Yes ❑ - No Property Owner's Name W QI) f� T I' 11 1 aW Dept • Mailing Address: City State Zip CONTACT/1PERSON-if there are questionss IIL about the submittal. j ,, Name: c v �VoO' Day Telephone: • W 22' L/6 Company Name:el Ue/jvl1 iah 1 JeCu Mailing Address: fl 13 I' I'M S • E-mail Address:a NICET III number: Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 2 , 000 cucticwwwn• Sl a% ,,tet 9615er Will State Zip c�� V) Fax Number: ontractor's City of Tukwila Business License number: '-&SCAC12.85L1 Scope of Work please provide detailed information): vivA- PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 ��l1134,: ZED AGENT: Signature: "x'rA ,� �,�' � :iI r 4f Print Name: �.D11�� Plan Permit App.doc Date:61 •1.. 20 1-4- Day 4Day Telephone: 2LXi 1.2 22 ' (Q 6i 8/22/14 11'1) FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Select Comfort 436 Southcenter Mall Permit No.: 08-S-165 Date: May 5, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Kitanda Espresso & Deli 436 Southcenter Mall Permit No.: 17-S-169 Date: September 14, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. • 1 • 1 N • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. GUARDIAN SECURITY Customer LIFE AND PROPERTY PROTECTION Vendor SELECT COMFORT Guardian Security Systems Inc 436 SOUTHCENTER MALL 1743 1st Ave. South ,'"KIWILA, WA 54478 Seattle, WA 98134 Phone #: (206)622-6545 Fax #: (206)628-4990 Type of Equipment FIRE ALARM Project Project # 54542 SELECT COMFORT ,List of Materials Date: 5/7/08 Item Qty. Manuf. Model Description Unit Pri Total Price 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) i \ 19) 20) 21) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) 33) 34) 35) 36) 37) 38) 39) 40) 41) 42) 43) 44) 45) 46) 47) 48) 49) 50) Siemens PAD -3 Siemens AD2-P Siemens HTRI-D Siemens HTRI-R Siemens SET CW,W Siemens ZR-MC-W,W Power Supply for Strobes with Standby** Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 Supervised Addressable Input Module Supervised Addressable Output Relay Module Interior Audible Speaker Annunciator Interior Visual Strobe Annunciator ** PAD -3 with BT -33 Conduit Systems: All smoke removal and detection and control devices in an approved metallic raceway and all devices in conduit per Standard © M.E.P.CAD, Inc. I:y AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:34PM Page 1 Hydraulic Overview II Job Number: KS0330 Report Description: Ordinary Group II Job Job Number KS0330 Design Engineer Andrew Chancellor Job Name Select Comfort Phone (425)881-0100 FAX (425)881-3030 Address 1 1006 Southcentner Mall State Certification/License Number WESTESF136QF Address 2 AHJ City of Tukwila City Tukwila State WA Zip Code 98188 Job Slte Southcenter Mall System Density 0.20gpm/ft2 Area of Application 1500.00ft2 (Actual 945.02ft2) Most Demanding Sprinkler Data 5.6 K -Factor 26.00 at 21.556 Hose Streams 250.00 Coverage Per Sprinkler 130.00ft2 Number 01 Sprinklers Calculated 10 System Pressure Demand 61.868 System Flow Demand 277.21 Total Demand 527.21 @ 61.868 Pressure Result +77.690 (55.7%) Supplies Check Point Gauges Node Flow(qpm) Hose Flow(gpm) Static(psi) Residual(psil Identifier Pressure(psi) K-Factor(K) Flow(qpm) 2 10900.00 250.00 140.000 20.000 Ole." NOS 1 II - t� NIEfab .f1g� r Select Comfort New 2 Supply at Node 2 (10900.00, 250.00, 140.000, 20.000) 150 _ =Static i i Pressure °�,; =,•-_._. 135 140.000 li 120 ''' 105 r• �� "J ° roc o 90 : r • ° In a ,- 75 o ° '_ N 60 527.21 wi h hose streams ,___° >_____ __r a 177.2 @ 61.868 —s s k: ... . 45 30• System demand curve • o 15 10900.00 @ 20.000 0c�Y�1.11111l1111IILII IIII11111111111111 111111111 111111111 111111111 111111111 111111111 1100 33000 5500 6600 7700 8800 9900 11000 Water flow, gpm © M.E.P.CAD, Inc. I:y AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:34PM Page 1 ©M.E.P.CAD, Inc. flyAutoSPRINKO VR5 v5.1.32 04/30/2008 4:25:45PM Page 2 Hydraulic Summary 1 Job Number: KS0330 Report Description: Ordinary Group II Job . Job Number KS0330 Design Engineer Andrew Chancellor Job Name Select Comfort State Certification/license Number WESTESF136QF Address 1 1006 Southcentner Mall AHJ City of Tukwila Address 2 Job Site Southcenter Mall City Tukwila State WA Zip Code 98188 Drawing Name Select Comfort New 2 System • Remote Area(s) Most Demanding Sprinkler Data 5.6 K -Factor 26.00 at 21.556 Occupancy Ordinary Group II Hose Allowance At Source 250.00 Density 0.20gpm/ft' Area of Application 1500.00ft' (Actual 945.02ft2) Additional Hose Supplies Node Flow(qpm) Number Of Sprinklers Calculated 10 Coverage Per Sprinkler 130.00ft2 AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Total Hose Streams 250.00 System Flow Demand 277.21 Total Water Required (Including Hose Allowance) 527.21 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 17.07 between nodes 182 and 35 Maximum Velocity Under Ground 1.05 between nodes 2 and 376 Volume capacity of Wet Pipes 2889.93ga1 Volume capacrty of Dry Pipes 0.75ft' Supplies Node Hose Flow (gpm) Static (psi) Residual @ FlowAvailable @ Total Demand (psi) (gpm) I (psi) (gpm) Required (psi) Safety Margin (psi) 2 250.00 140.000 20.000 1 10900.00 I 139.558 1 527.21 61.868 77.690 Contractor Contractor Number KS0330 Contact Name Andrew Chancellor Contact Title Project Manager Contractor Name Western States Fire Protection Phone (425)881-0100 Extension Address 1 7102 180th Ave Ne, Suite A-105 FAX (425)881-3030 Address 2 E-mail City Redmond State WA Zip Code 98052 Web -Site ©M.E.P.CAD, Inc. flyAutoSPRINKO VR5 v5.1.32 04/30/2008 4:25:45PM Page 2 M.E.P.CAD, Inc. 41,6 AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:46PM Page 3 Summary Of Outflowing Devices Job Number: KS0330 Report Description: Ordinary Group II Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Density (gpmpft2) Sprinkler 104 26.84 26.00 5.6 22.969 0.21gpm/ft2 c Sprinkler 101 26.00 26.00 5.6 21.556 0.20gpm/ft2 Sprinkler 102 26.32 26.00 5.6 22.096 0.20gpm/ft2 Sprinkler 103 26.60 26.00 5.6 22.570 0.20gpm/ft2 Sprinkler 105 27.12 26.00 5.6 23.461 0.21gpm/ft2 Sprinkler 106 27.23 26.00 5.6 23.646 0.21gpm/ft2 Sprinkler 107 28.04 26.00 5.6 25.075 0.22gpm/ft2 0.22gpm/ft2 Sprinkler 108 28.15 26.00 5.6 25.277 Sprinkler 109 30.38 30.51 26.00 26.00 5.6 5.6 29.428 29.688 0.23gpm/ft2 0.23gpm/ft2 Sprinkler 110 c Most Demanding Sprinkler Data M.E.P.CAD, Inc. 41,6 AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:46PM Page 3 I; 4 [:i (Hydraulic Analysis L Job Number: KS0330 Report Description: Ordinary Group 11 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Upstream Eq. Length Total Length Summary OD Route 1 DR 1.049 0=26.00 9.65 C=120 0.211435 27-3'4 Pf 7.676 101 12-0% q=26.00 K=5.6 21.556 Spr(-21.556) 20 12-6 29.037 2E(2-0), PO(5-0) 9-0 Pe -0.195 36-3'/4 Pv BL 1.610 0=52.84 8.33 C=120 0.097470 10-OY Pf 0.979 20 12-6 29.037 28 12-6 30.019 Pe 0.003 10-0'/ Pv BL 1.610 Q=79.96 12.60 C=120 0.209777 10-0 Pf 2.098 28 12-6 30.019 32 12-6 32.117 10-0 Pe 0.000 Pv BL 1.610 0=108.01 17.02 C=120 0.365834 8-4 Pf 5.982 32 12-6 32.117 180 12-6 38.099 P0(8-0) 8-0 16-4 Pe 0.000 Pv CM 4.260 0=138.38 3.11 C=120 0.005063 20- Pf 0.101 180 12-6 38.099 182 12-6 38.201 20- Pe -0.000 Pv CM 4.260 0=277.21 6.24 C=120 0.018307 392-1'/4 Pf 11.045 182 12-6 38.201 346 -0-1 54.694 12fE(8-11'/2), 2P0(26-4), 2fEE(4-5'/2), 2Ee2(5-3), CV(28-11'/), GV(2-7%) 211-2'/3 603-4 Pe 5.448 Pv FM 8.329 Q=277.21 1.63 C=120 0.000699 21-10 Pf 0.038 346 -0-1 54.694 336 -0-1 54.731 2fE(16-0) 32-0 53-10 Pe -0.000 Pv MS 10.020 0=277.21 1.13 C=120 0.000284 20-2 Pf 4.525 336 -0-1 54.731 67-0 376 3-8 57.621 3LtE(16-0), BV(19-0), BFP(-4.500) 87-2 Pe -1.635 Pv UG 10.400 0=277.21 1.05 C=140 0.000178 113-1 Pf 0.046 376 3-8 57.621 146-8 2 -6-0 61.868 3LtE(25-6), E(35-1), 2EE(17-6%), 259-9'1IPv S Pe 4.200 w Route 2 DR 1.049 0=26.32 9.77 C=120 0.216326 28-7Y Pf 6.624 102 10-0% q=26.32 K=5.6 22.096 Spr(-22.096) 24 12-6 27.659 E(2-0) 2- Pe -1.060 30-7Y Pv AO 1.380 0=52.93 11.35 C=120 0.207138 2-2Y Pf 1.701 24 12-6 27.659 25 12-6 29.362 PO(6-0) 6-0 Pe 0.002 8-2'% Pv BL 1.610 0=52.93 8.34 C=120 0.097775 7-4 Pf 0.717 25 12-6 29.362 31 12-6 30.079 7-4 Pe 0.000 Pv BL 1.610 Q=80.16 12.63 C=120 0.210730 10-0 Pf 2.107 31 12-6 30.079 35 12-6 32.187 10-0 Pe Pv BL 1.610 0=108.31 17.07 C=120 0.367771 8-4 Pf 6.014 35 12-6 32.187 182 12-6 38.201 P0(8-0) 8-0 16-41 Pe Pv v Route 3 DR 1.049 0=26.60 9.88 C=120 0.220621 24-9'/2 Pf 7.016 103 8-0% q=26.60 K=5.6 22.570 Spr(-22.570) 24 12-6 27.659 E(2-0), T(5-0) 7-0 31-9'/2 Pe -1.927 Pv Route 4 DR 1.049 Q=26.84 9.96 C=120 0.224223 22-10'/ Pf 6.029 104 12-0'/2 q=26.84 K=5.6 22.969 Spr(-22.969) 18 12-6 28.799 2E(2-0) 4-0 Pe -0.199 26-10'/4 Pv BL 1.610 0=26.84 4.23 C=120 0.027837 8-5 Pf 0.234 18 12-6 28.799 20 12-6 29.037 Pe 0.004 8-5 Pv w Route 5 DR 1.049 0=27.12 10.07 C=120 0.228664 26-3Y Pf 7.617 105 10-0% q=27.12 K=5.6 23.461 Spr(-23.461) 28 12-6 30.019 E(2-0), P0(5-0) 7- Pe -1.058 33-3'/ Pv ea Route 6 DR 1.049 0=27.23 10.11 C=120 0.230332 25-6Y Pf 7.491 106 10-0% q=27.23 K=5.6 23.646 Spr(-23.646) 31 12-6 30.079 E(2-0), P0(5-0) 7- 32-61/ Pe -1.058 Pv v Route 7 DR 1.049 0=28.04 10.41 C=120 0.243180 26-3'/4 Pf 8.100 107 10-0% q=28.04 K=5.6 25.075 Spr(-25.075) 32 12-6 32.117 E(2-0), P0(5-0) 7- Pe -1.058 33-3'/4 Pv a► Route 8 © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:47PM Page 4 M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:47PM Page 5 Hydraulic Analysis Job Number: KS0330 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Summary Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream Eq. Length Total Length DR 1.049 Q=28.15 10.45 C=120 0.244988 25-6'% Pf 7.968 108 10-0% q=28.15 K=5.6 25.277 Spr(-25.277) 35 12-6 32.187 E(2-0), PO(5-0) 7-0 Pe -1.058 32-6'% Pv fab Route 9 DR 1.049 Q=30.38 11.28 C=120 0.281983 26-3% 7-0 33-3% Pf 9.393 Pe -1.059 Pv 109 10-0% q=30.38 K=5.6 29.428 Spr(-29.428) 221 12-6 37.761 E(2-0), PO(5-0) BL 1.610 Q=30.38 4.79 C=120 0.035007 1-9 8-0 9-8 Pf 0.338 Pe 0.001 Pv 221 12-6 37.761 180 12-6 38.099 P0(8-0) ea Route 10 DR 1.049 Q=30.51 11.33 C=120 0.284288 25-6'% 7-10,Pe 32-6'% Pf 9.246 -1.059 Pv 110 10-0% q=30.51 K=5.6 29.688 Spr(-29.688) 222 12-6 37.875 E(2-0), PO(5-0) BL 1.610 Q=30.51 4.81 C=120 0.035293 1-2'% 8-0 9-2%z Pf 0.325 Pe 0.000 Pv 222 12-6 37.875 182 12-6 38.201 PO(8-0) Equivalent Pipe Lengthsof Valves and Fittings (C=120 only) ` C Value Multiplier Actual Inside Diameter Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 )4.87 Schedule 40 Steel Pipe Inside Diameter = Factor Pipe Type Legend Units Legend Fittings Legend AO Arm -Over BL Branch Line CM Cross Main ON Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen -Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow .% Eel 11W Elbow Ee2 22W Elbow f Flow Device FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Tum Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:47PM Page 5 (!� ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:49PM Page 6 Hydraulic Graph . Job Number: KS0330 Report Description: Ordinary Group II Supply at Node 2 150 = :Static 135 Pressure 140.000 120 105 90 'V1 a P 75 to to g2. J527.2 60 with hose @ 61.868 streams -277.21 45 30 System demand curve 15 10900.00 @ 20.000_ 0 MW 111111 111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 II I 1 1 1 1 1 1 1 1 1 111111111 11002200 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hydraulic Graph Supply at Node 2 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.558 @ 527.21 System Demand 277.21 @ 61.868 System Demand (Including Hose Allowance) 527.21 @ 61.868 (!� ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:49PM Page 6 TYPICAL FLEXABLE SPRINKLER CONNECTION SELECT COMFORT Ordinary Group II.O.2Ogpm/ft2 for 9 5.00ft2 w? ;> SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE:...... IN STANDARD LENGTHS 2X4 CEILING TILE 12'-0" AFF GYP BD CEILING 10'-0" AFF GYP BD CEILING 8'-0" AFF FLEXHEAD DETAIL NOT TO SCALE 318' KWIK BOLT (2I K' EMBED LENGTH) ]IB' KWIK BOLT 02 I W EMBED LENGTH) FIG. 609 SWIVEL SWAY BRACE FITTING F10.909 NO.THREAD SWIVEL SWAY BRACE ATTACHMENT General Notes 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 fie maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. BRACE PIPE FIG.1000 ��'"FAST CLAMP' BRACE PIPE SWAY BRACE ATTACHMENT LRE PIPE GYP BD CEILING 10'-0" AFF FIG.4A PIPE CLAMP FOR SWAY BRACE OLATERAL BRANCHLINE RESTRAINT r I NON -THREADED BRACE PIPE GYP BD CEILING 10'-0" AFF LATERAL BRANCHLINE RESTRAINT NOT TO SCALE SPRINKLER MAIN (TYP.) 12'-6" AFF EXISTING WELDED OUTLETS SELECT COMFORT Remote Area: Retail # 436 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 oCCUPANCYcLass ORD HAZARD 11 MAX. COVERAGE per HEAD 130 DENSITY .20 GPM / Ft' for 945 FN SPRINKLER Reliable Model G4A ORIFICE 12" K= 5.6 GYP BD SOFFIT 9'-0" AFF RESIDUAL 20 FLOW 10900 PSI PSI GPM Concrete Construction Swivel Ring AT BASE OF RISER, SYSTEM REQUIRES: 277.21 GPM © 57.62 PSI • At time of Design 12%0" CLG.=37%AREA REDUCTION Note on Plan: Hanger Number and 'A' Dimension NOTE:\PPROv DE SPRINKLER HEA .PIN CAVATIES (Tr P) HANGER DETAIL NOT TO SCALE NOTE:\PPROVIDE SPRINKLER HEAD \PIs, CAVATIES (TYP) GYP BD SOFFIT 10'-0" AFF WEST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE GYP BD SOFFIT 10'-0" AFF NORTH FIRE SPRINKLER PLAN 0' 2' 4' 8' 12' Scale: 1 /4" =11-0" VICINITY MAP DETAIL SYMBOL LEGEND REVISIONS Sprinkler Legend APPROVAL: City of Tukwila 2 -WAY EARTHQUAKE BRACE 4 -WAY EARTHQUAKE BRACE DESCRIPTION HYDRAULIC REFERENCE POINT QTY. 2 15 Total =17 K SPRAY Upright MFR./MODEL Brass 155°F CONT. NO.: KS0330 Western States Fire Pendent Chrome 155°F HANGER SYMBOL DRAWN BY: Andrew Chancellor SPRK. ON SHEET: SEE LEGEND SPRK. ON JOB: 07/21/08 Protection Company 7102180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136OF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS / DECATURI DENVER/ DULUTH IHOUSTON /KANSAS CITY LAS VEGAS/MINNEAPOLIS/PHOENIX/PORTLAND/ RAPID CITY/ ST. PAUL/SALT LAKE CITY/SEATTLE Phone: 425.881-0100 Fac:425.881-3030 Select Comfort 1006 Southcentner Mall Tukwila ,WA 98188 FIRE SPRINKLER PLAN SHEET SO DDI I ON S LET NUN/ 3E� SHE T TITLE SYST V \FO V ATI O \ FA -J2 TYDICAL WHI \G AND V OU\ TI\ G DETAILS FA -(33 SYSTE v CALCULATIO\S A\D SI \GLE LI\E DIAGAIv FA -04 FI ALAN SYSTEiv LA \ 0 SHEET INDEX Without Comments As Noted in Red Per The Attached Letter These plans h we been reviewed by The Tukwila Fire Prevention Bu 'eau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize Violations of adopted c.`andards and ordinances. The responsibility for the G_iequacy of design rests totally with the designer, dditions, deletions or revisions to these drawings after E this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approvat1.31 Final acceptance issuo, ect-to-field-test_and Inspection by The Tukwila F re Prevention Bureau. Date: c•-•11-1-7-1----7 By: I-UKWILA FIRE DEPARTME`fTPlease call 206-575-4407 and give this_Firq Permit No. /7-}-- /7cc7 and exact Town or r RELOCATE 1 EXISTING CEILING MOUNT SPEAKER/STROBE S SHOWN ON THE PLAN FOR THIS TENANT IMPROVEMENT WIRE SC H SCOPE OF WORK D„ LE A\ 3 CONDUIT FILL CHART 6sta-rationapproval. WIRE 1ESIGNATIIN I I SYMBOL DESCRIPTION NUMBER DF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .245 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA -OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BF,SED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED \VIRE TO BE GROUNDED Al P❑INT ❑F ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY E 1 (E) 1 (E) 2 (E) 1 (E) 1 (E) 2 (E) SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING I-iEUHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL I D DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS EXISTING 66" A.F.F. TO TOP VERIFY IN FIELD TSM E DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS EXISTING VERIFY IN FIELD HT -R INTERFACE MODULE E WITH RELAY (EXISTING) HTRI-R SIEMENS EXISTING VERIFY IN FIELD FIRE ALARM SLE STROBE (EXISTING) ZR -MC -W SIEMENS EXISTING 80" A.F.F. TO L3OTl-OM gER FIRE ALARM SPEAKER STROBE (EXISTING -RELOCATED) SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2" EXTN CEILING FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING DE TENANT J -BOX (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD ti END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A E EXISTING DEVICE N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N /A NI/A N ,• RED AS BUILT ADD OR CHANGE N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND I NORDSTROM LL•:i_LS T macyS KITANDA ESPRESSO & ACAI SUITE 1005 0 Proprietary and SITE PLAN Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved PAID SA=P 07 2017 TUKWILA FIRE u LU L LL LU 01 od D 0 )z I H - C1 5 Cri 2" Cf) wcr U� I w �Y Z Lrf, SCALE: NOT T. DRAWN BY: D. GARCIA DESIGNED BY: T_QUAALE DATE: 09/05/ BACKROUND PLAN ARU`i LU BY woe NUMbER: -r SHEET A-- THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET -- SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 12OVAC-6OHZ — DEDICATED EMERGENCY • FROM EXISTING MAIN FACP C CABLE C' CABLE V ORO N L 0 o� 0 0 PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - m _Ir 1-6 ww_imm-msnmnm 3.6k EOL 0 0 (+) (-) (+) HARD LID CEILING HARD LID —\ SPEAKER SUPPORT TILE BRIDGE 2 NAC S4 NAC S3 RETURN TO EXISTING NAC S2 VOICE CIRCUIT NAC S1 (V' CABLE) 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSION CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) PAD -3 POWER SUPPLY WIRING DETAIL (+) (-) STROBE SPEAKER FROM PREVIOUS ADDRESSABLE 2 DEVICE HFP-11 TB'I ®®®® ®0C) NO COM NC TO FAN SHUTDOWN EOLR J 470 SWITCH + INPUT LED TSM -1 00 00 TO NEXT ADDRESSABLE DEVICE 0 4 &IS /1/1/ HTRI-R NO ® COM B NC ® 0 02 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL ((+) STROBE STROBE SPEAKER (+) (-) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. MI Rigrlts Reserved (n z 0 U) Q' LLJ (-n w J W CO w c0 0 n I LJ Ji rr) T - DESCRIPTION SHOP DRAWINGS cj- LIJ L) 0 0 f ®l 0 0 z 'SCALE: NOT TC SCALE_ DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/05/ , 7 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 477: -- i SHEET A O , KITANDA E FIRE ALARM BOOSTER Project: KITANDA ESPRESSO Panel: EXISTING BPS PAD -3 Date: September 5, 2017 Module/Device POWER & ACAI REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 Current Load: 140 Standby: Alarm: Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 4897 Total(A)= 15 Total(B)= 5037 CALCULATION Total current ratings of all devices in system (line A + line B + line C) Device Type Qty Amps Total Amps Total 24 HFP-11 Multiply lines E and F Total Standby AH 0.0022 0.0022 0.0023 0.000 0.0833 FDBZ492-HR (EX) 1 0.0635 0.0635 0.064 0.064 Multiply line J by 1.2 (20% extra insurance to meet desired performance) HTRI MODULE (EX) 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps A B C D E F G H 1 J K FIRE ALARM BOOSTER Project: KITANDA ESPRESSO Panel: EXISTING BPS PAD -3 Date: September 5, 2017 Module/Device POWER & ACAI REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 4897 Total(A)= 15 Total(B)= 5037 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 5037 Total current ratings converted to amperes (line D x .001) 0.015 5.037 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.4195821 Add lines G and I Total Standby and Alarm AH 0.7795821 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.93549852 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 CALCULATIONS Notification Appliance Circuit Detail PROJECT: KITANDA ESPRESSO & ACM Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLY Wire Resistance 2.58 Date: September 5, 2017 CURRENT TOTAL= 4897.00 SET -MC -CW @l5cd 3 SET -MC -CW @30cd SET -MC -CW @75cd SET -MC -CW @95cd 1 ZR -MC -W @15cd DEVICES 4 69 111 200 264 64 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps s (I) Voltage Drop (E ) EOL Voltage 0 333 0 0 64 397 14 263 23.46 397 DEVICES MAXIMUM LOAD TOTAL mA= 1500 DEVICES MAXIMUM LOAD ( WL * 2 ) * (Rift) (Total Cct Load) (E=l*R) 24 - E) 1.36 0.40 0.54 23.46 DEVICES MAXIMUM LOAD TOTAL mA= 1500 1500 �E S S4-1 15cd S4-2 30cd s,v E SIV b S4-3 30cd EOL S4 D C EXISTING TENANT J -BOX D,1 HT -RIE 214 TSM IE SINGLE LINE DIAGRAM S4-4 30cd HT -R E FLAG NOTES: EXISTING RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. RELOCATE EXISTING SPEAKER/STROBE TO NEW SPECIFIED LOCATION. Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved u-, 0 cn LLJ LJJ Lll J W 0 LJ CD LL. :Jr) • DESCRIPTIO SHOP DRAWINGS C u) 0 <_ .4 f �..rJ cD CO Z�co 06 0_ col- -5 a) L)o ODZ Q Do LL,! w z Q -Cr I co <c Ili ccws <0 J S ---.i d CC 0 Z u_ U cD SCALE: NO I I U 5(..;ALL DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/05[17 BACKROUND PLAN PROVIDED BY: �0B NUMBER: -477: SHEET - FA -03 FLAG NOTES: EXISTING RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. RELOCATE EXISTING SPEAKER/STROBE TO NEW SPECIFIED LOCATION. S4-1 15cd NL��"moi"\ NSW.. PLAN KEY NOTES NEW CUSTOM CASEWORK STORAGE AND DISPLAY UNIT. NEW CUSTOM PASTRY ENCLOSURE SIDE ROWNG FOLDING SECURITY GRIUI. EXISTING ELECTRICAL PANELS TO REMAIN. EXISTING TRANSFORMER TO REMAIN. EMPLOYEE LOCKERS (N.I.C.). CASEWORK WITH OPEN SHELVING ACCESSIBLE FROM BEHIND, FOR STORAGE MIN. 36` DEEP X 8' WIDE STACKING CAVITY FOR SIDE ROLLING FOLDING SECURITY GRAIL DOOR WITH CONCEALED HINGES TO ENCLOSE ROWNG DOOR CAVITY. SEE INTERIOR ELEVATIONS FOR FINISH. BARN TRACK FOR MENUS AND CABINETS BY RUST1CA HARDWARE PROVIDE BLOCKING SECURED TO WALL L SHAPED METAL ANGLE TRASH, COMPOST AND RECYCLE ENCLOSURE W/ 1/4' STEEL ENCLOSURE AND DOOR W/MAGNERC CLOSURE SEAL k STAIN CONCRETE FLOOR. RAISED BAR HEIGHT COUNTER. NOT USED. EXISTING I.T. CASEWORK TO REMAIN. CLIENT TO PROVIDE OWN I.T. INSTALL AND SERVICE 34"H CASEWORK. 3611 CASEWORK. NEW SEMI -RECESSED FIRE EXDNGUISHER CABINET, NEW FLOOR SINK. VERIFY TELEPHONE OUTLET/HOOK UP EXISTS 1/2' CLEAR ANODIZED ALUM. REVEAL AT BASE OF EXIST. COLUMN, NO EXPOSED FASTENERS. p } /-1 (E S4-3 30cd EOL S4 S4-4 30cd S4-2 30cd • ! . ' 2 gER US Tei :-�-F;JUG �i 12 T- -- 1;! = II I_ 1 !, I I1- _a II fl= - — — -- -- — I FIRE ALARM SYSTEM PLAN Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ;1_ V J RELEASE/REVISIONS 0 DESCRIPTION SHOE DRAWINGS { LL1 Lr) O 0 0 C SALE: 1 /4" -r", 'L) DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/05/ BACKROUND PLAN JOB NUMBER: / PROVIDED BY: -- +/721 � i SHEET FA -04 SHEET NUMBER FILE COPY SHEET. TITLE FA -01 SHEET INDEX SYSTEM INFORMATION I TUKWHAAQ \\TASHING'I' FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLAN 1 • Without vi.)rornents O As Noted In Red O Per The Aitached Letter a !nese plans have been Dori ,eb by The T&,,fila Fire Prevention Bureau or con;orr3:i;.in .e with current city standards. Acceptance is •Lit ;: t to errors and omissions v'h'ch do no: authorize violations oi adopted standards and arcnn.inc !,, . f'. .'onsibi4ty for the adequacy of :. ;>i (i ;<'_c."y• '; %G11 'ifiE ti enigner. Additions, inese drawings atter this d to mil LC7 trlr:i� �C=',i,ri l t: Mrd will require a resubmittal of revised drewir: tar Liubseduent approval. Final acceptance is subject to field test and inspection by Tht. Tukwila Fire. Prevention Bureau. I Date: c.") By: ) l I fUKWILA FIRE DEPART& ENI Please call: 575-4407 and give this job and exact address for shut+ down or restoration approval: NOTICE A.completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART.._ .- NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V X12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V x{18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL. DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND, DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED: NO PARALLEL BRANCHING IS PERMISSIBLE. 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, VIVRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES.! g_ FOR ADDITIONAL INSTALLATION INSTRUCTIONS,. REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS.. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE: 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN!' REFERENCE TO DEDICATED. BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM;; TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED .CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL:=BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS' WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS. COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION .FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM; FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED -ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT; IRRESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED 747 SYMBOLS LEGEND QUANTITY SYMBOL' DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP Pr) c0 C1` 0 I-- z_ uJ _J a Lu (1) 0 (J LU F- (/) i0 2 1 3 1 1 ® INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD dKI LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -CW SIEMENS SET -MC -W SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM EFIRE ALARM SPEAKER STROBE C.i( (CEILING MOUNT) SET -HMC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM © STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. 9c FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM FIRE ALARM B b' ` STROBE WP (WEATHERPROOF) SET -S 17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.O. F.B.❑. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.D. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A AS BUILT RED • ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved :lam co co � -21§za) 00 W WO -zz (.)CEO= C.� � o 5 W 2 'SCALE: 1/8"=1' 0 0 z u.J N } (1) DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:5/05/08 BACKROUND PLAN PROVIDED BY: �OB NUMBER:54542 SHEET FA -O 1 THE DUCT SMOKE DE1ECT(X4 ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT IABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE t � FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC 111-1 1 -0 END OF LINE DEVICE(3.6K 1/4W) Pr) SUPERVISED SWITCH --------- GROUND LCl 0 HTRI-R DUCT DETECTOR LOCATION e - STATUS LED t` (0 0 0 0 N.O. COM NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. o O /) //_} TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE L _ (BACKGOUND MUSIC SHUTDOWN) Taal TB 1 NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH- C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING----\ TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE 4 -AC POKER SOURCE COMBINE ALL SHIELDS : AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE `O STOP IF LAST DEVICE -) FROM XLS CONTROL PANEL OR, PREVIOUS ADDRESSABLE DEVICE�t-) RELAY CONTACTS (4.0A 2 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED. SWITCHES MUST BE HELD CLOSED AND/OR OPEN -FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. l ,S)B00 1 2 3 4 5 6 1 HCP END OF LINE DEVICE : 0 (3.6K 1/4W).. SUPERVISED % SWITCH GROUND --_ M 0 0 HTRI- STATUS LED co 0 t` 0 SNOT USED 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. -TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL (FIRE SUPPRESSION SYSTEM INTERFACE) - FRONT MEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE to 0 0 DEVICE LOOP err FROM XLS CONTROL PAIEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE r POWER SUPPLY L ('S' CABLE) END OF LINE DEVICE FROM FACP 3.6K 1/413/) (VOICE CIRCUIT) ;'; ('V' CABLE) SUPERVISED. SWITCH` 0 . GND N AC 11 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX '1+ 1- 1 2+ 2- 2 NC C NO + - El DI 1311* 24K + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE NAC -4 NAC -3 NAC -2 NAC -1 470 OHMS IW EOL TSM -1 0 SME TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE 0 CO (-) - STR❑BE SPEAKER �) (-) u ( STROBE-) EARTH • GROUND -->(+)TO NEXT DEVICE OR ). >(-) STOP IF LAST DEVICE CO (_) STROBE SPEAKER'' (+) (-) SPEAKER/STROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80- &F -F. R E 4S DEEP BOX W/ 1-1/2' EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE DR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE NICE OR POKER SOURCE fDATA IN (-) > DATA IN (-F) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 30D-4000 FT IN WHEN USED IN CONJJNCTION TH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL ma SCALE TO NEXT DEVICE > ( ) DATA OUT (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID -- CEILING HARD LID -7\ . ------SPEAKER SUPPORT BRIDGE ------ 4' SQUARE. DEEP BOX -- WITH 1-1/2' EXTENSION --- CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE - JUNCTI❑N BOX MOUNTED ON \ CEILINGI FLEX \` JUNCTI N BOX ------� MOUNTED AGAINST CEILING S PPORT SMOKE DETECTOR ----- SMOKE DETECTOR MOUNTING SCALE:NONE T O O TO NEXT DEVICE / / / / -----CADDY BAR SUSPENDED ILLUMINATED CEILING Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved W y :514 TEL. (206) 622-6545 RELEASE/REVISIONS DESCRIPTION LU I- Q 0 \ In Ii) <«< co co CC Q LLwccp mow= C.) cc = uw wcf 0 w tlt� 04. II� 1— /SCALE: — z z 0 0 z 0. z _J 1-- LL! ' ALE: 1/8"=1' DRAWN BY: I.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: �OB : NUMBER: 54542 % SHEET FA -02 , EOL—S1 20.09V X P2I N < Iv) LI_"* -1 2S,2 1 0 ITT • .! ! • ‘.! • I ' • IL. ['AC 3 0 MI •i •i' r-. ; . I \ t--"" 2I D,I L. L \ 0 111 30 /' i\ 1 I 2S,2V / I MI 0 75 L -1 VA- 1 -• • : 0 SELECT COMFORT WESTFIELD SOUTHCENTER MALL SCALE 1/814 /Th ---. ; FLAG NODS: • FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNIT SXSEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. • • I . f 1743 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NVI DESCRIPTION SHOP DRAWINGS FOR AHJ LIJ 1.-- < CO 0 ,..... in in 0 0 0 co CC DILL 133 0 2 § za) w fro llj z z w -±- cn <1.3- Lij 0 CC Ci)5 (/) ggp w • F- cr cc /S-CALE: 1/8"=1' DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: :'; , .t.JOB NUMBER:54542 fl,• - ie:: SHEET • !':;' 1:i..,. ;,!'- Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved- . FA -03 } I- NORDSTROM t A 1 ' Vv ;AGE _EPS P.AREL'11ERIE EBNC:i%AS1 .- C)-I_I I)C• NORTH -1 SELEC R EiIAGIO �JLj <S ELE ; 1'=1 VEERIZON WIRELE..) MADE N WASHINGTON SPENCER GIFTS r:RASH Ss, C C.) m T v PIJ ?C ;C;RR. ELEC' lij --7 j arc.- 1 i'1' M ALL OFFICE MAL GFFICE SELECT COMFORT WESTFIELD SOUTHCENTER MALL _ _ _ SCALE 1132'4 30 C 15 C 30 C 75 C EOL -S1 20.09V RISER DIAG EX SYSTEM CALCULATIONS ATTERY SIZING CALCULATION Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: SELECT COMFORT Date: ;May 7, 2008 ;Wire Resistance 1.62 CURRENT TOTAL=.435 CIRCUIT: S1 QTY 0 0 DEVICES= Device Type SET -MC @15CD SET -MC @30CD :SET -MC @75CD 1SET MC @110CD .__.. `SET-HMC-C@115CD :SET-HMC-C@177CD SET -HMC @135CD SET -HMC @185CD Z-MC@15CD Z-MC@30CD SET-MC-CW@11 OCD ;Alarm Current; Alarm Total Wire Size 641 98! 1961 1751 1.75 2331 0 3181 0 4451 3181 445 641 64 981 0 Wire Length Voltage at EOL Circuit Total •;Total Wire Resistance (R ) (WL*2)*(R/ft)_...._..__.___ :Total Device Load, Amps (I) (Total Cct Load) 2333 Of TOTAL m A=' 4351 12 ` 220 20.089932 _ Notification Appliance CircuitDetail PROJECT:'WESTFIELD SOUTHCENTER MALL Panel: SELECT COMFORT Date:: May 6, 2008 CIRC.UIT:=SPEAKERCIRCUIT QTY Device Type ;Alarm Currentl Alarm Total Wire Size Wire Length 70.7V1/8 435 Voltage Drop (E ) (E= I * R) EOL Voltage (20.4-E) Wire Resistance 2.58 CURRENT TOTAL=15.4 Voltage at EOL Circuit Total 0.44; 0.31; 20.09 !Total Wire Resistance (R ) ( WL * 2 )*(R/ft)..__. ;Total Device Load, Amps (1) otal Cct Load) !Voltage Drop (E (E=I*R) EOL Voltage (20.4 - E) 1.14, 0.01; 0.01 20.391 20.39386992 5.4 VOLTAGE DROP CALCULATION rr ") CO 0' z 0 z_ cnuJ w cn 0 1743 IST AVE. 0' 0' • N 0 TEL. (206) 622-6545 RELEASE/REVISIONS C1) w z DESCRIPTION SHOP DRAWINGS FOR AHJ LU 11) In J i'- cco o <°)W.W �z oco cn D 2 w= <�� WQ - W mac_ W� CC w z w C) z 0 J 0 w C!) >- C1) 6ALE: 1/8"=ls DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER:54542 SHEET FA -04 SELECT COMFORT - - SELECT COMFORT FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations Current Load: Standby: Alarm: Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 AD2-P 1 0.0635 0.0635 0.064 0.064 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R HTRI-D ICP -B6 2 0.009600 0.0096 0.021 0.042 SET -MC @15CD SET -MC @30CD SET -MC @75CD SET -MC @110CD SET HMC-C@115CD SET HMC-C@135CD SE -T4 -1 -MC -C@185 -CD ZR -MC @15CD ZR -MC @30CD HCP 0.064 0.001600 0.0035 2 0.098 0.196 0.005 1 0.175 0.175 0.233 0.318 0.318 0.0731 Amps 0.106 Amps 0.445 1 0.064 0.064 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours 0.098 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.03 Amps 0.465 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.465 Amps For 5 Minutes= 0.039 Amp -hours Total System Current Load: 2.204 Amp -hours 25%.Derating= 0.949 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: - 0.949 Amp -hours I Battery Pair to be Used: 12VDC Amp -hours 7AH ATTERY SIZING CALCULATION Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: SELECT COMFORT Date: ;May 7, 2008 ;Wire Resistance 1.62 CURRENT TOTAL=.435 CIRCUIT: S1 QTY 0 0 DEVICES= Device Type SET -MC @15CD SET -MC @30CD :SET -MC @75CD 1SET MC @110CD .__.. `SET-HMC-C@115CD :SET-HMC-C@177CD SET -HMC @135CD SET -HMC @185CD Z-MC@15CD Z-MC@30CD SET-MC-CW@11 OCD ;Alarm Current; Alarm Total Wire Size 641 98! 1961 1751 1.75 2331 0 3181 0 4451 3181 445 641 64 981 0 Wire Length Voltage at EOL Circuit Total •;Total Wire Resistance (R ) (WL*2)*(R/ft)_...._..__.___ :Total Device Load, Amps (I) (Total Cct Load) 2333 Of TOTAL m A=' 4351 12 ` 220 20.089932 _ Notification Appliance CircuitDetail PROJECT:'WESTFIELD SOUTHCENTER MALL Panel: SELECT COMFORT Date:: May 6, 2008 CIRC.UIT:=SPEAKERCIRCUIT QTY Device Type ;Alarm Currentl Alarm Total Wire Size Wire Length 70.7V1/8 435 Voltage Drop (E ) (E= I * R) EOL Voltage (20.4-E) Wire Resistance 2.58 CURRENT TOTAL=15.4 Voltage at EOL Circuit Total 0.44; 0.31; 20.09 !Total Wire Resistance (R ) ( WL * 2 )*(R/ft)..__. ;Total Device Load, Amps (1) otal Cct Load) !Voltage Drop (E (E=I*R) EOL Voltage (20.4 - E) 1.14, 0.01; 0.01 20.391 20.39386992 5.4 VOLTAGE DROP CALCULATION rr ") CO 0' z 0 z_ cnuJ w cn 0 1743 IST AVE. 0' 0' • N 0 TEL. (206) 622-6545 RELEASE/REVISIONS C1) w z DESCRIPTION SHOP DRAWINGS FOR AHJ LU 11) In J i'- cco o <°)W.W �z oco cn D 2 w= <�� WQ - W mac_ W� CC w z w C) z 0 J 0 w C!) >- C1) 6ALE: 1/8"=ls DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER:54542 SHEET FA -04 SELECT COMFORT VICINITY MAP (Suite# 436) SCALE: NTS General Notes 1. Western States Fire Protection to add new pendent heads new u ri ht heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with Nt-PA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to -ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40ipe.: 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with FPA, as well as state & local codes. 7. he owner is responsible for the freeze protection of all sprinkler system piping and components at are of designed tor freezingconditions. 8. xisteng tire spriftler system to emain. Western States Fire Protection will modify the existing system on1 in the areas.ofwork. All other areas are not in contract and WSFP is not responsible for existing conditions. WEST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE Ordinary Group 11oO.2Ogpmlft2 for 9 ! 5.00ft2 2X4 CEILING TILE 12'-0" AFF BRANCHLINE (TYP.) 12'-6" AFF GYP BD CEILING 10'-0" AFF GYP BID CEILING 1(Y-0" AFF 1%1/4\ 102 R1 -EM 0 SPRINKLER MAIN (TYP.I, 12'-6" AFF 6-11 NOTE:\PPROVIDE SPRINKLER HEA Q \PIN CAVATIES (TYP) \\ GYP BD SOFFIT 10'-0" AFF R1 -NL 0 R2 0 T (3) T1 (9 GYP BD CEILING 8'-0" AFF GYP BD CEILING 10'-0" AFF EXISTING WELDED OUTLETS • GYP BD SOFFIT 9'-0" AFF Baa lawasommoomatossessomeasmow NOTE:\PPROVIDE SPRINKLER HEAD \PIN CAVATIES (TYP) NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping rior to hydrostatic test provai. GYP BD SOFFIT 10'-0" AFF • FIRE SPRINKLER PLAN FUKWILA FIRE DEPARTMENT, Please call: 575-440Z and give this job lea. — — I(e,, *;'d rjxact address for shut, ').it/.'n or r4-stdration approve,: f� t D TYPICAL FLEXABLE SPRINKLER CONNECTION;; FLEXHEAD SPRINKLER BRANCHLINE LEXABLE CONNECTING HOSE. • :'.:':..: IN STANDARD LENGTHS SUSPENDED T -BAR GRID CEILING TILE SPRINKLER HEAD FLEXHEAD DETAIL NOT TO SCALE FIG. 909 AI SWIVEL BRACE FITTING Nir BRACE PIPE FIG. 1000 (2 13/4-+EMBiED PENGTH) "FAST ��) SWAY RAMC ATTACHMENT NLINE PIPE LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE SELECT COMFORT Remote Area: Retail # 436 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD 11 MAX. COVERAGE per HEAD 130 DENSITY .20 GPM FP for 945 SPRINKLER Reliable Model G4A Ft' ORIFICE 1t2'l lc- 6.6 WATER FLOW INFORM/zTON% STATIC 14u PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 277.21 GPM (f457.62 ' fPSI ,.^ Yj T [, 'At time of Design 12'-6" CLG =37%a AREA REDUCTION Without Comments As Noted In Red Per The Attached Letter I nese plan have l: =:"_ r: I..:.. t;y ri- Tulcvii!a Fire Prevention Bum.-!.., current city standards. !a omissions standards and adequacy o` Additions, d: :: this date, will V. "• 'ii. 'C`. `,' i G'/rl1 i/ CLIVI i resubmittal of .,,utg t /ytl ill: 019prt1v-i. and . i„,F cns of adopted .:nc I; t, for the deoignor, drew1irlfr+ <+iityr Final accopt::ncr: I .;; ; :',f~al�ld ih � � �,,ti n gF t� , 1The Tukwila Fura,i�t_.,.. Date: 3l1 0' 2' 4' Scale: 114” = 1'-0" 8' 12' FIG.4 PIPE CLAMP FOR SWAY BRACE OLATERAL BRANCHLINE RESTRAINT NON -THREADED BRACE PIPE (2 13/1.IED LENGTH) FIG. 909 NO -THREAD SWIVEL SWAY BRACEATTACHME i BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III Cut Rod Lgth Rounded to Nearest Inch Rod Coupling —` All Thread Rod Swivel Ring \ Concrete Construction Bottom of Concrete to Cantor Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE 2008 Tukwila Fire zs -77 Select Comfort 0 Andrew Chance Timberwolff Construction SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY SPRAY ORIF. FIN TEMP. MFR./MODEL APPROVAL: City of Tukwila 4 -WAY EARTHQUAKE BRACE 2 5.6 Upright '/z' Brass 155°F 1 HYDRAULIC REFERENCE POINT 15 5.6 Pendent 12" Chrome 155°F CONT. NO.: KS0330 HANGER SYMBOL Total = 17 DRAWN BY: Andrew Chancellor BRANCHLINE RESTRAINT • SPRK. ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 04/30/0$ Western States Fire Protection Company 7102180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY -OFFICES LOCATED ALBUQUERQUE /AUSTIN !DALLAS / DECATUR / DENVER /DULUTH /HOUSTON /KANSAS CITY LAS VEGAS IMINNEAPOUS/ PHOENIX / PORTLAND !RAPID CITY/ ST. PALL /SALT LAKE CITY !SEATTLE Phone: 425.881.0100 Fax 425-881-3030 Select Comfort p4p 1006 Southcentner Mall Tukwila ,WA 98188 FIRE SPRINKLER PLAN SHEET FP -1 OF 1 436 SOUTHCENTER MALL ASSOCIATED PERMITS 17-F-170 08-F-175 17-S-169 17-S-168 08-S-165 4isittlav444 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address:_ . sootIvertier yn4I Suite Number: OM Floor: Tenant Name: K..\\04A j Ycsst * t New Tenant? ❑ - Yes ❑ - No +- 6rtp SITE LOCATION Property Owner's Name: W � -Q .. Mar Mailing Address: City CONTACT PERSON -if there are questions about the submittal. Name: GY IS -VW Company Name: State Zip Day Telephone: 142S '9 %1 "7(0(09 Govan \V - t ether V Mailing Address: U ` WI �1` l.._ Y X-1 \)N qRutz City State Zip Fax Number: E-mail Address: Total number of new/relocated devices or sprinkler heads: 7 Valuation of Project (contractor's bid price): $ 1 ,5Cxz)g:0 Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. _ I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Plan Permit App.doc Jess ica Date: ...30.17 Day Telephone: 1425 • '1 1) ' UV/ 1/2/13 TFD FP Form 8 441 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION King Co. Assessor's Tax No.:Ct 202141.00 I 0 Site Addre • : o ce v U 1.)NA aAtet Suite Number: Floor: Tenant Name: r I ka U1tS/l. Er s New Tenant? 0- Yes ❑ - No Property Owner's Name W QI) f� T I' 11 1 aW Dept • Mailing Address: City State Zip CONTACT/1PERSON-if there are questionss IIL about the submittal. j ,, Name: c v �VoO' Day Telephone: • W 22' L/6 Company Name:el Ue/jvl1 iah 1 JeCu Mailing Address: fl 13 I' I'M S • E-mail Address:a NICET III number: Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 2 , 000 cucticwwwn• Sl a% ,,tet 9615er Will State Zip c�� V) Fax Number: ontractor's City of Tukwila Business License number: '-&SCAC12.85L1 Scope of Work please provide detailed information): vivA- PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 ��l1134,: ZED AGENT: Signature: "x'rA ,� �,�' � :iI r 4f Print Name: �.D11�� Plan Permit App.doc Date:61 •1.. 20 1-4- Day 4Day Telephone: 2LXi 1.2 22 ' (Q 6i 8/22/14 11'1) FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Select Comfort 436 Southcenter Mall Permit No.: 08-S-165 Date: May 5, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Kitanda Espresso & Deli 436 Southcenter Mall Permit No.: 17-S-169 Date: September 14, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. • 1 • 1 N • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. GUARDIAN SECURITY Customer LIFE AND PROPERTY PROTECTION Vendor SELECT COMFORT Guardian Security Systems Inc 436 SOUTHCENTER MALL 1743 1st Ave. South ,'"KIWILA, WA 54478 Seattle, WA 98134 Phone #: (206)622-6545 Fax #: (206)628-4990 Type of Equipment FIRE ALARM Project Project # 54542 SELECT COMFORT ,List of Materials Date: 5/7/08 Item Qty. Manuf. Model Description Unit Pri Total Price 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) i \ 19) 20) 21) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) 33) 34) 35) 36) 37) 38) 39) 40) 41) 42) 43) 44) 45) 46) 47) 48) 49) 50) Siemens PAD -3 Siemens AD2-P Siemens HTRI-D Siemens HTRI-R Siemens SET CW,W Siemens ZR-MC-W,W Power Supply for Strobes with Standby** Photoelectric Duct Detector housing w/Sample Tubes, Remote TSM -1 Supervised Addressable Input Module Supervised Addressable Output Relay Module Interior Audible Speaker Annunciator Interior Visual Strobe Annunciator ** PAD -3 with BT -33 Conduit Systems: All smoke removal and detection and control devices in an approved metallic raceway and all devices in conduit per Standard © M.E.P.CAD, Inc. I:y AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:34PM Page 1 Hydraulic Overview II Job Number: KS0330 Report Description: Ordinary Group II Job Job Number KS0330 Design Engineer Andrew Chancellor Job Name Select Comfort Phone (425)881-0100 FAX (425)881-3030 Address 1 1006 Southcentner Mall State Certification/License Number WESTESF136QF Address 2 AHJ City of Tukwila City Tukwila State WA Zip Code 98188 Job Slte Southcenter Mall System Density 0.20gpm/ft2 Area of Application 1500.00ft2 (Actual 945.02ft2) Most Demanding Sprinkler Data 5.6 K -Factor 26.00 at 21.556 Hose Streams 250.00 Coverage Per Sprinkler 130.00ft2 Number 01 Sprinklers Calculated 10 System Pressure Demand 61.868 System Flow Demand 277.21 Total Demand 527.21 @ 61.868 Pressure Result +77.690 (55.7%) Supplies Check Point Gauges Node Flow(qpm) Hose Flow(gpm) Static(psi) Residual(psil Identifier Pressure(psi) K-Factor(K) Flow(qpm) 2 10900.00 250.00 140.000 20.000 Ole." NOS 1 II - t� NIEfab .f1g� r Select Comfort New 2 Supply at Node 2 (10900.00, 250.00, 140.000, 20.000) 150 _ =Static i i Pressure °�,; =,•-_._. 135 140.000 li 120 ''' 105 r• �� "J ° roc o 90 : r • ° In a ,- 75 o ° '_ N 60 527.21 wi h hose streams ,___° >_____ __r a 177.2 @ 61.868 —s s k: ... . 45 30• System demand curve • o 15 10900.00 @ 20.000 0c�Y�1.11111l1111IILII IIII11111111111111 111111111 111111111 111111111 111111111 111111111 1100 33000 5500 6600 7700 8800 9900 11000 Water flow, gpm © M.E.P.CAD, Inc. I:y AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:34PM Page 1 ©M.E.P.CAD, Inc. flyAutoSPRINKO VR5 v5.1.32 04/30/2008 4:25:45PM Page 2 Hydraulic Summary 1 Job Number: KS0330 Report Description: Ordinary Group II Job . Job Number KS0330 Design Engineer Andrew Chancellor Job Name Select Comfort State Certification/license Number WESTESF136QF Address 1 1006 Southcentner Mall AHJ City of Tukwila Address 2 Job Site Southcenter Mall City Tukwila State WA Zip Code 98188 Drawing Name Select Comfort New 2 System • Remote Area(s) Most Demanding Sprinkler Data 5.6 K -Factor 26.00 at 21.556 Occupancy Ordinary Group II Hose Allowance At Source 250.00 Density 0.20gpm/ft' Area of Application 1500.00ft' (Actual 945.02ft2) Additional Hose Supplies Node Flow(qpm) Number Of Sprinklers Calculated 10 Coverage Per Sprinkler 130.00ft2 AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Total Hose Streams 250.00 System Flow Demand 277.21 Total Water Required (Including Hose Allowance) 527.21 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 17.07 between nodes 182 and 35 Maximum Velocity Under Ground 1.05 between nodes 2 and 376 Volume capacity of Wet Pipes 2889.93ga1 Volume capacrty of Dry Pipes 0.75ft' Supplies Node Hose Flow (gpm) Static (psi) Residual @ FlowAvailable @ Total Demand (psi) (gpm) I (psi) (gpm) Required (psi) Safety Margin (psi) 2 250.00 140.000 20.000 1 10900.00 I 139.558 1 527.21 61.868 77.690 Contractor Contractor Number KS0330 Contact Name Andrew Chancellor Contact Title Project Manager Contractor Name Western States Fire Protection Phone (425)881-0100 Extension Address 1 7102 180th Ave Ne, Suite A-105 FAX (425)881-3030 Address 2 E-mail City Redmond State WA Zip Code 98052 Web -Site ©M.E.P.CAD, Inc. flyAutoSPRINKO VR5 v5.1.32 04/30/2008 4:25:45PM Page 2 M.E.P.CAD, Inc. 41,6 AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:46PM Page 3 Summary Of Outflowing Devices Job Number: KS0330 Report Description: Ordinary Group II Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Density (gpmpft2) Sprinkler 104 26.84 26.00 5.6 22.969 0.21gpm/ft2 c Sprinkler 101 26.00 26.00 5.6 21.556 0.20gpm/ft2 Sprinkler 102 26.32 26.00 5.6 22.096 0.20gpm/ft2 Sprinkler 103 26.60 26.00 5.6 22.570 0.20gpm/ft2 Sprinkler 105 27.12 26.00 5.6 23.461 0.21gpm/ft2 Sprinkler 106 27.23 26.00 5.6 23.646 0.21gpm/ft2 Sprinkler 107 28.04 26.00 5.6 25.075 0.22gpm/ft2 0.22gpm/ft2 Sprinkler 108 28.15 26.00 5.6 25.277 Sprinkler 109 30.38 30.51 26.00 26.00 5.6 5.6 29.428 29.688 0.23gpm/ft2 0.23gpm/ft2 Sprinkler 110 c Most Demanding Sprinkler Data M.E.P.CAD, Inc. 41,6 AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:46PM Page 3 I; 4 [:i (Hydraulic Analysis L Job Number: KS0330 Report Description: Ordinary Group 11 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Upstream Eq. Length Total Length Summary OD Route 1 DR 1.049 0=26.00 9.65 C=120 0.211435 27-3'4 Pf 7.676 101 12-0% q=26.00 K=5.6 21.556 Spr(-21.556) 20 12-6 29.037 2E(2-0), PO(5-0) 9-0 Pe -0.195 36-3'/4 Pv BL 1.610 0=52.84 8.33 C=120 0.097470 10-OY Pf 0.979 20 12-6 29.037 28 12-6 30.019 Pe 0.003 10-0'/ Pv BL 1.610 Q=79.96 12.60 C=120 0.209777 10-0 Pf 2.098 28 12-6 30.019 32 12-6 32.117 10-0 Pe 0.000 Pv BL 1.610 0=108.01 17.02 C=120 0.365834 8-4 Pf 5.982 32 12-6 32.117 180 12-6 38.099 P0(8-0) 8-0 16-4 Pe 0.000 Pv CM 4.260 0=138.38 3.11 C=120 0.005063 20- Pf 0.101 180 12-6 38.099 182 12-6 38.201 20- Pe -0.000 Pv CM 4.260 0=277.21 6.24 C=120 0.018307 392-1'/4 Pf 11.045 182 12-6 38.201 346 -0-1 54.694 12fE(8-11'/2), 2P0(26-4), 2fEE(4-5'/2), 2Ee2(5-3), CV(28-11'/), GV(2-7%) 211-2'/3 603-4 Pe 5.448 Pv FM 8.329 Q=277.21 1.63 C=120 0.000699 21-10 Pf 0.038 346 -0-1 54.694 336 -0-1 54.731 2fE(16-0) 32-0 53-10 Pe -0.000 Pv MS 10.020 0=277.21 1.13 C=120 0.000284 20-2 Pf 4.525 336 -0-1 54.731 67-0 376 3-8 57.621 3LtE(16-0), BV(19-0), BFP(-4.500) 87-2 Pe -1.635 Pv UG 10.400 0=277.21 1.05 C=140 0.000178 113-1 Pf 0.046 376 3-8 57.621 146-8 2 -6-0 61.868 3LtE(25-6), E(35-1), 2EE(17-6%), 259-9'1IPv S Pe 4.200 w Route 2 DR 1.049 0=26.32 9.77 C=120 0.216326 28-7Y Pf 6.624 102 10-0% q=26.32 K=5.6 22.096 Spr(-22.096) 24 12-6 27.659 E(2-0) 2- Pe -1.060 30-7Y Pv AO 1.380 0=52.93 11.35 C=120 0.207138 2-2Y Pf 1.701 24 12-6 27.659 25 12-6 29.362 PO(6-0) 6-0 Pe 0.002 8-2'% Pv BL 1.610 0=52.93 8.34 C=120 0.097775 7-4 Pf 0.717 25 12-6 29.362 31 12-6 30.079 7-4 Pe 0.000 Pv BL 1.610 Q=80.16 12.63 C=120 0.210730 10-0 Pf 2.107 31 12-6 30.079 35 12-6 32.187 10-0 Pe Pv BL 1.610 0=108.31 17.07 C=120 0.367771 8-4 Pf 6.014 35 12-6 32.187 182 12-6 38.201 P0(8-0) 8-0 16-41 Pe Pv v Route 3 DR 1.049 0=26.60 9.88 C=120 0.220621 24-9'/2 Pf 7.016 103 8-0% q=26.60 K=5.6 22.570 Spr(-22.570) 24 12-6 27.659 E(2-0), T(5-0) 7-0 31-9'/2 Pe -1.927 Pv Route 4 DR 1.049 Q=26.84 9.96 C=120 0.224223 22-10'/ Pf 6.029 104 12-0'/2 q=26.84 K=5.6 22.969 Spr(-22.969) 18 12-6 28.799 2E(2-0) 4-0 Pe -0.199 26-10'/4 Pv BL 1.610 0=26.84 4.23 C=120 0.027837 8-5 Pf 0.234 18 12-6 28.799 20 12-6 29.037 Pe 0.004 8-5 Pv w Route 5 DR 1.049 0=27.12 10.07 C=120 0.228664 26-3Y Pf 7.617 105 10-0% q=27.12 K=5.6 23.461 Spr(-23.461) 28 12-6 30.019 E(2-0), P0(5-0) 7- Pe -1.058 33-3'/ Pv ea Route 6 DR 1.049 0=27.23 10.11 C=120 0.230332 25-6Y Pf 7.491 106 10-0% q=27.23 K=5.6 23.646 Spr(-23.646) 31 12-6 30.079 E(2-0), P0(5-0) 7- 32-61/ Pe -1.058 Pv v Route 7 DR 1.049 0=28.04 10.41 C=120 0.243180 26-3'/4 Pf 8.100 107 10-0% q=28.04 K=5.6 25.075 Spr(-25.075) 32 12-6 32.117 E(2-0), P0(5-0) 7- Pe -1.058 33-3'/4 Pv a► Route 8 © M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:47PM Page 4 M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:47PM Page 5 Hydraulic Analysis Job Number: KS0330 Report Description: Ordinary Group II Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Summary Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream Eq. Length Total Length DR 1.049 Q=28.15 10.45 C=120 0.244988 25-6'% Pf 7.968 108 10-0% q=28.15 K=5.6 25.277 Spr(-25.277) 35 12-6 32.187 E(2-0), PO(5-0) 7-0 Pe -1.058 32-6'% Pv fab Route 9 DR 1.049 Q=30.38 11.28 C=120 0.281983 26-3% 7-0 33-3% Pf 9.393 Pe -1.059 Pv 109 10-0% q=30.38 K=5.6 29.428 Spr(-29.428) 221 12-6 37.761 E(2-0), PO(5-0) BL 1.610 Q=30.38 4.79 C=120 0.035007 1-9 8-0 9-8 Pf 0.338 Pe 0.001 Pv 221 12-6 37.761 180 12-6 38.099 P0(8-0) ea Route 10 DR 1.049 Q=30.51 11.33 C=120 0.284288 25-6'% 7-10,Pe 32-6'% Pf 9.246 -1.059 Pv 110 10-0% q=30.51 K=5.6 29.688 Spr(-29.688) 222 12-6 37.875 E(2-0), PO(5-0) BL 1.610 Q=30.51 4.81 C=120 0.035293 1-2'% 8-0 9-2%z Pf 0.325 Pe 0.000 Pv 222 12-6 37.875 182 12-6 38.201 PO(8-0) Equivalent Pipe Lengthsof Valves and Fittings (C=120 only) ` C Value Multiplier Actual Inside Diameter Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 )4.87 Schedule 40 Steel Pipe Inside Diameter = Factor Pipe Type Legend Units Legend Fittings Legend AO Arm -Over BL Branch Line CM Cross Main ON Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen -Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow .% Eel 11W Elbow Ee2 22W Elbow f Flow Device FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Tum Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:47PM Page 5 (!� ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:49PM Page 6 Hydraulic Graph . Job Number: KS0330 Report Description: Ordinary Group II Supply at Node 2 150 = :Static 135 Pressure 140.000 120 105 90 'V1 a P 75 to to g2. J527.2 60 with hose @ 61.868 streams -277.21 45 30 System demand curve 15 10900.00 @ 20.000_ 0 MW 111111 111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 II I 1 1 1 1 1 1 1 1 1 111111111 11002200 3300 4400 5500 6600 7700 8800 9900 11000 Water flow, gpm Hydraulic Graph Supply at Node 2 Static Pressure 140.000 Residual Pressure 10900.00 @ 20.000 Available PressureTime of Test 139.558 @ 527.21 System Demand 277.21 @ 61.868 System Demand (Including Hose Allowance) 527.21 @ 61.868 (!� ©M.E.P.CAD, Inc. AutoSPRINK® VR5 v5.1.32 04/30/2008 4:25:49PM Page 6 TYPICAL FLEXABLE SPRINKLER CONNECTION SELECT COMFORT Ordinary Group II.O.2Ogpm/ft2 for 9 5.00ft2 w? ;> SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE:...... IN STANDARD LENGTHS 2X4 CEILING TILE 12'-0" AFF GYP BD CEILING 10'-0" AFF GYP BD CEILING 8'-0" AFF FLEXHEAD DETAIL NOT TO SCALE 318' KWIK BOLT (2I K' EMBED LENGTH) ]IB' KWIK BOLT 02 I W EMBED LENGTH) FIG. 609 SWIVEL SWAY BRACE FITTING F10.909 NO.THREAD SWIVEL SWAY BRACE ATTACHMENT General Notes 1. Western States Fire Protection to add new pendent heads new upright heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with NFPA #13 Ordinary hazard Occupancy with 130 fie maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40 pipe. 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 7. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 8. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in the areas of work. All other areas are not in contract and WSFP is not responsible for existing conditions. BRACE PIPE FIG.1000 ��'"FAST CLAMP' BRACE PIPE SWAY BRACE ATTACHMENT LRE PIPE GYP BD CEILING 10'-0" AFF FIG.4A PIPE CLAMP FOR SWAY BRACE OLATERAL BRANCHLINE RESTRAINT r I NON -THREADED BRACE PIPE GYP BD CEILING 10'-0" AFF LATERAL BRANCHLINE RESTRAINT NOT TO SCALE SPRINKLER MAIN (TYP.) 12'-6" AFF EXISTING WELDED OUTLETS SELECT COMFORT Remote Area: Retail # 436 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 oCCUPANCYcLass ORD HAZARD 11 MAX. COVERAGE per HEAD 130 DENSITY .20 GPM / Ft' for 945 FN SPRINKLER Reliable Model G4A ORIFICE 12" K= 5.6 GYP BD SOFFIT 9'-0" AFF RESIDUAL 20 FLOW 10900 PSI PSI GPM Concrete Construction Swivel Ring AT BASE OF RISER, SYSTEM REQUIRES: 277.21 GPM © 57.62 PSI • At time of Design 12%0" CLG.=37%AREA REDUCTION Note on Plan: Hanger Number and 'A' Dimension NOTE:\PPROv DE SPRINKLER HEA .PIN CAVATIES (Tr P) HANGER DETAIL NOT TO SCALE NOTE:\PPROVIDE SPRINKLER HEAD \PIs, CAVATIES (TYP) GYP BD SOFFIT 10'-0" AFF WEST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE GYP BD SOFFIT 10'-0" AFF NORTH FIRE SPRINKLER PLAN 0' 2' 4' 8' 12' Scale: 1 /4" =11-0" VICINITY MAP DETAIL SYMBOL LEGEND REVISIONS Sprinkler Legend APPROVAL: City of Tukwila 2 -WAY EARTHQUAKE BRACE 4 -WAY EARTHQUAKE BRACE DESCRIPTION HYDRAULIC REFERENCE POINT QTY. 2 15 Total =17 K SPRAY Upright MFR./MODEL Brass 155°F CONT. NO.: KS0330 Western States Fire Pendent Chrome 155°F HANGER SYMBOL DRAWN BY: Andrew Chancellor SPRK. ON SHEET: SEE LEGEND SPRK. ON JOB: 07/21/08 Protection Company 7102180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136OF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE/AUSTIN/DALLAS / DECATURI DENVER/ DULUTH IHOUSTON /KANSAS CITY LAS VEGAS/MINNEAPOLIS/PHOENIX/PORTLAND/ RAPID CITY/ ST. PAUL/SALT LAKE CITY/SEATTLE Phone: 425.881-0100 Fac:425.881-3030 Select Comfort 1006 Southcentner Mall Tukwila ,WA 98188 FIRE SPRINKLER PLAN SHEET SO DDI I ON S LET NUN/ 3E� SHE T TITLE SYST V \FO V ATI O \ FA -J2 TYDICAL WHI \G AND V OU\ TI\ G DETAILS FA -(33 SYSTE v CALCULATIO\S A\D SI \GLE LI\E DIAGAIv FA -04 FI ALAN SYSTEiv LA \ 0 SHEET INDEX Without Comments As Noted in Red Per The Attached Letter These plans h we been reviewed by The Tukwila Fire Prevention Bu 'eau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize Violations of adopted c.`andards and ordinances. The responsibility for the G_iequacy of design rests totally with the designer, dditions, deletions or revisions to these drawings after E this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approvat1.31 Final acceptance issuo, ect-to-field-test_and Inspection by The Tukwila F re Prevention Bureau. Date: c•-•11-1-7-1----7 By: I-UKWILA FIRE DEPARTME`fTPlease call 206-575-4407 and give this_Firq Permit No. /7-}-- /7cc7 and exact Town or r RELOCATE 1 EXISTING CEILING MOUNT SPEAKER/STROBE S SHOWN ON THE PLAN FOR THIS TENANT IMPROVEMENT WIRE SC H SCOPE OF WORK D„ LE A\ 3 CONDUIT FILL CHART 6sta-rationapproval. WIRE 1ESIGNATIIN I I SYMBOL DESCRIPTION NUMBER DF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .245 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA -OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BF,SED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED \VIRE TO BE GROUNDED Al P❑INT ❑F ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY E 1 (E) 1 (E) 2 (E) 1 (E) 1 (E) 2 (E) SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING I-iEUHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL I D DUCT SMOKE DETECTOR (EXISTING) FDBZ492-HR W/ HFP-11 DET. SIEMENS EXISTING 66" A.F.F. TO TOP VERIFY IN FIELD TSM E DUCT DETECTOR TEST SWITCH (EXISTING) TSM -1 SIEMENS EXISTING VERIFY IN FIELD HT -R INTERFACE MODULE E WITH RELAY (EXISTING) HTRI-R SIEMENS EXISTING VERIFY IN FIELD FIRE ALARM SLE STROBE (EXISTING) ZR -MC -W SIEMENS EXISTING 80" A.F.F. TO L3OTl-OM gER FIRE ALARM SPEAKER STROBE (EXISTING -RELOCATED) SET -MC -CW SIEMENS 4S DEEP W/ 1-1/2" EXTN CEILING FIRE ALARM SPEAKER STROBE (EXISTING) SET -MC -CW SIEMENS EXISTING CEILING DE TENANT J -BOX (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD ti END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A E EXISTING DEVICE N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N /A NI/A N ,• RED AS BUILT ADD OR CHANGE N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND I NORDSTROM LL•:i_LS T macyS KITANDA ESPRESSO & ACAI SUITE 1005 0 Proprietary and SITE PLAN Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved PAID SA=P 07 2017 TUKWILA FIRE u LU L LL LU 01 od D 0 )z I H - C1 5 Cri 2" Cf) wcr U� I w �Y Z Lrf, SCALE: NOT T. DRAWN BY: D. GARCIA DESIGNED BY: T_QUAALE DATE: 09/05/ BACKROUND PLAN ARU`i LU BY woe NUMbER: -r SHEET A-- THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET -- SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 12OVAC-6OHZ — DEDICATED EMERGENCY • FROM EXISTING MAIN FACP C CABLE C' CABLE V ORO N L 0 o� 0 0 PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - m _Ir 1-6 ww_imm-msnmnm 3.6k EOL 0 0 (+) (-) (+) HARD LID CEILING HARD LID —\ SPEAKER SUPPORT TILE BRIDGE 2 NAC S4 NAC S3 RETURN TO EXISTING NAC S2 VOICE CIRCUIT NAC S1 (V' CABLE) 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSION CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) PAD -3 POWER SUPPLY WIRING DETAIL (+) (-) STROBE SPEAKER FROM PREVIOUS ADDRESSABLE 2 DEVICE HFP-11 TB'I ®®®® ®0C) NO COM NC TO FAN SHUTDOWN EOLR J 470 SWITCH + INPUT LED TSM -1 00 00 TO NEXT ADDRESSABLE DEVICE 0 4 &IS /1/1/ HTRI-R NO ® COM B NC ® 0 02 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL ((+) STROBE STROBE SPEAKER (+) (-) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. MI Rigrlts Reserved (n z 0 U) Q' LLJ (-n w J W CO w c0 0 n I LJ Ji rr) T - DESCRIPTION SHOP DRAWINGS cj- LIJ L) 0 0 f ®l 0 0 z 'SCALE: NOT TC SCALE_ DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/05/ , 7 BACKROUND PLAN PROVIDED BY: \OB NUMBER: 477: -- i SHEET A O , KITANDA E FIRE ALARM BOOSTER Project: KITANDA ESPRESSO Panel: EXISTING BPS PAD -3 Date: September 5, 2017 Module/Device POWER & ACAI REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 Current Load: 140 Standby: Alarm: Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 4897 Total(A)= 15 Total(B)= 5037 CALCULATION Total current ratings of all devices in system (line A + line B + line C) Device Type Qty Amps Total Amps Total 24 HFP-11 Multiply lines E and F Total Standby AH 0.0022 0.0022 0.0023 0.000 0.0833 FDBZ492-HR (EX) 1 0.0635 0.0635 0.064 0.064 Multiply line J by 1.2 (20% extra insurance to meet desired performance) HTRI MODULE (EX) 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps A B C D E F G H 1 J K FIRE ALARM BOOSTER Project: KITANDA ESPRESSO Panel: EXISTING BPS PAD -3 Date: September 5, 2017 Module/Device POWER & ACAI REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 4897 Total(A)= 15 Total(B)= 5037 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 5037 Total current ratings converted to amperes (line D x .001) 0.015 5.037 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.4195821 Add lines G and I Total Standby and Alarm AH 0.7795821 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.93549852 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 CALCULATIONS Notification Appliance Circuit Detail PROJECT: KITANDA ESPRESSO & ACM Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLY Wire Resistance 2.58 Date: September 5, 2017 CURRENT TOTAL= 4897.00 SET -MC -CW @l5cd 3 SET -MC -CW @30cd SET -MC -CW @75cd SET -MC -CW @95cd 1 ZR -MC -W @15cd DEVICES 4 69 111 200 264 64 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps s (I) Voltage Drop (E ) EOL Voltage 0 333 0 0 64 397 14 263 23.46 397 DEVICES MAXIMUM LOAD TOTAL mA= 1500 DEVICES MAXIMUM LOAD ( WL * 2 ) * (Rift) (Total Cct Load) (E=l*R) 24 - E) 1.36 0.40 0.54 23.46 DEVICES MAXIMUM LOAD TOTAL mA= 1500 1500 �E S S4-1 15cd S4-2 30cd s,v E SIV b S4-3 30cd EOL S4 D C EXISTING TENANT J -BOX D,1 HT -RIE 214 TSM IE SINGLE LINE DIAGRAM S4-4 30cd HT -R E FLAG NOTES: EXISTING RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. RELOCATE EXISTING SPEAKER/STROBE TO NEW SPECIFIED LOCATION. Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved u-, 0 cn LLJ LJJ Lll J W 0 LJ CD LL. :Jr) • DESCRIPTIO SHOP DRAWINGS C u) 0 <_ .4 f �..rJ cD CO Z�co 06 0_ col- -5 a) L)o ODZ Q Do LL,! w z Q -Cr I co <c Ili ccws <0 J S ---.i d CC 0 Z u_ U cD SCALE: NO I I U 5(..;ALL DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/05[17 BACKROUND PLAN PROVIDED BY: �0B NUMBER: -477: SHEET - FA -03 FLAG NOTES: EXISTING RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. EXISTING DUCT DETECTOR, RELAY MODULE & TEST SWITCH. RELOCATE EXISTING SPEAKER/STROBE TO NEW SPECIFIED LOCATION. S4-1 15cd NL��"moi"\ NSW.. PLAN KEY NOTES NEW CUSTOM CASEWORK STORAGE AND DISPLAY UNIT. NEW CUSTOM PASTRY ENCLOSURE SIDE ROWNG FOLDING SECURITY GRIUI. EXISTING ELECTRICAL PANELS TO REMAIN. EXISTING TRANSFORMER TO REMAIN. EMPLOYEE LOCKERS (N.I.C.). CASEWORK WITH OPEN SHELVING ACCESSIBLE FROM BEHIND, FOR STORAGE MIN. 36` DEEP X 8' WIDE STACKING CAVITY FOR SIDE ROLLING FOLDING SECURITY GRAIL DOOR WITH CONCEALED HINGES TO ENCLOSE ROWNG DOOR CAVITY. SEE INTERIOR ELEVATIONS FOR FINISH. BARN TRACK FOR MENUS AND CABINETS BY RUST1CA HARDWARE PROVIDE BLOCKING SECURED TO WALL L SHAPED METAL ANGLE TRASH, COMPOST AND RECYCLE ENCLOSURE W/ 1/4' STEEL ENCLOSURE AND DOOR W/MAGNERC CLOSURE SEAL k STAIN CONCRETE FLOOR. RAISED BAR HEIGHT COUNTER. NOT USED. EXISTING I.T. CASEWORK TO REMAIN. CLIENT TO PROVIDE OWN I.T. INSTALL AND SERVICE 34"H CASEWORK. 3611 CASEWORK. NEW SEMI -RECESSED FIRE EXDNGUISHER CABINET, NEW FLOOR SINK. VERIFY TELEPHONE OUTLET/HOOK UP EXISTS 1/2' CLEAR ANODIZED ALUM. REVEAL AT BASE OF EXIST. COLUMN, NO EXPOSED FASTENERS. p } /-1 (E S4-3 30cd EOL S4 S4-4 30cd S4-2 30cd • ! . ' 2 gER US Tei :-�-F;JUG �i 12 T- -- 1;! = II I_ 1 !, I I1- _a II fl= - — — -- -- — I FIRE ALARM SYSTEM PLAN Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ;1_ V J RELEASE/REVISIONS 0 DESCRIPTION SHOE DRAWINGS { LL1 Lr) O 0 0 C SALE: 1 /4" -r", 'L) DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 09/05/ BACKROUND PLAN JOB NUMBER: / PROVIDED BY: -- +/721 � i SHEET FA -04 SHEET NUMBER FILE COPY SHEET. TITLE FA -01 SHEET INDEX SYSTEM INFORMATION I TUKWHAAQ \\TASHING'I' FA -02 TYPICAL DETAILS - WIRING AND MOUNTING FA -03 FIRE ALARM SYSTEM FLOOR PLAN FA -04 SYSTEM CALCULATIONS (GENERAL), RISER, SITE PLAN 1 • Without vi.)rornents O As Noted In Red O Per The Aitached Letter a !nese plans have been Dori ,eb by The T&,,fila Fire Prevention Bureau or con;orr3:i;.in .e with current city standards. Acceptance is •Lit ;: t to errors and omissions v'h'ch do no: authorize violations oi adopted standards and arcnn.inc !,, . f'. .'onsibi4ty for the adequacy of :. ;>i (i ;<'_c."y• '; %G11 'ifiE ti enigner. Additions, inese drawings atter this d to mil LC7 trlr:i� �C=',i,ri l t: Mrd will require a resubmittal of revised drewir: tar Liubseduent approval. Final acceptance is subject to field test and inspection by Tht. Tukwila Fire. Prevention Bureau. I Date: c.") By: ) l I fUKWILA FIRE DEPART& ENI Please call: 575-4407 and give this job and exact address for shut+ down or restoration approval: NOTICE A.completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) 2S STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) 2V SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATI❑N TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART.._ .- NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V X12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V x{18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL. DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND, DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED: NO PARALLEL BRANCHING IS PERMISSIBLE. 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, VIVRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES.! g_ FOR ADDITIONAL INSTALLATION INSTRUCTIONS,. REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS.. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE: 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN!' REFERENCE TO DEDICATED. BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM;; TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED .CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL:=BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS' WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS. COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION .FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM; FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED -ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT; IRRESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED 747 SYMBOLS LEGEND QUANTITY SYMBOL' DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP Pr) c0 C1` 0 I-- z_ uJ _J a Lu (1) 0 (J LU F- (/) i0 2 1 3 1 1 ® INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD T -D DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD dKI LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING DUCT SMOKE DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING FIRE ALARM SPEAKER STROBE (CEILING MOUNT) FIRE ALARM SPEAKER STROBE (WALL MOUNT) SET -MC -CW SIEMENS SET -MC -W SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. 4S DEEP BOX 80" A.F.F. W/ 1-1/2" EXT. TO BOTTOM EFIRE ALARM SPEAKER STROBE C.i( (CEILING MOUNT) SET -HMC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING FIRE ALARM © STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.O.N. 9c FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. FIRE ALARM SPEAKER (WALL MOUNT) SET -W SIEMENS 4S DEEP BOX W/ 1-1/2" EXT. 80" A.F.F. TO BOTTOM FIRE ALARM B b' ` STROBE WP (WEATHERPROOF) SET -S 17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201/C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.O. F.B.❑. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.D. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A AS BUILT RED • ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved :lam co co � -21§za) 00 W WO -zz (.)CEO= C.� � o 5 W 2 'SCALE: 1/8"=1' 0 0 z u.J N } (1) DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE:5/05/08 BACKROUND PLAN PROVIDED BY: �OB NUMBER:54542 SHEET FA -O 1 THE DUCT SMOKE DE1ECT(X4 ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT IABEL SCALE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE t � FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC 111-1 1 -0 END OF LINE DEVICE(3.6K 1/4W) Pr) SUPERVISED SWITCH --------- GROUND LCl 0 HTRI-R DUCT DETECTOR LOCATION e - STATUS LED t` (0 0 0 0 N.O. COM NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. o O /) //_} TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE L _ (BACKGOUND MUSIC SHUTDOWN) Taal TB 1 NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH- C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - MUSIC OUTLET SAMPLING----\ TUBE INLET SAMPLING TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE 4 -AC POKER SOURCE COMBINE ALL SHIELDS : AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE `O STOP IF LAST DEVICE -) FROM XLS CONTROL PANEL OR, PREVIOUS ADDRESSABLE DEVICE�t-) RELAY CONTACTS (4.0A 2 125VAC) (4.0A @ 30VDC) 27 VDC 3.5 r1A DURING POLLING 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED. SWITCHES MUST BE HELD CLOSED AND/OR OPEN -FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. l ,S)B00 1 2 3 4 5 6 1 HCP END OF LINE DEVICE : 0 (3.6K 1/4W).. SUPERVISED % SWITCH GROUND --_ M 0 0 HTRI- STATUS LED co 0 t` 0 SNOT USED 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. -TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL (FIRE SUPPRESSION SYSTEM INTERFACE) - FRONT MEW NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE to 0 0 DEVICE LOOP err FROM XLS CONTROL PAIEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> FROM REMOTE r POWER SUPPLY L ('S' CABLE) END OF LINE DEVICE FROM FACP 3.6K 1/413/) (VOICE CIRCUIT) ;'; ('V' CABLE) SUPERVISED. SWITCH` 0 . GND N AC 11 0 PAD -3 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX '1+ 1- 1 2+ 2- 2 NC C NO + - El DI 1311* 24K + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE NAC -4 NAC -3 NAC -2 NAC -1 470 OHMS IW EOL TSM -1 0 SME TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCALE NONE 0 CO (-) - STR❑BE SPEAKER �) (-) u ( STROBE-) EARTH • GROUND -->(+)TO NEXT DEVICE OR ). >(-) STOP IF LAST DEVICE CO (_) STROBE SPEAKER'' (+) (-) SPEAKER/STROBE AND STROBE WIRING LABEL SCALE SPEAKER STROBE OR STROBE ONLY 80- &F -F. R E 4S DEEP BOX W/ 1-1/2' EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) SPEAKER/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE TO NEXT DEVICE OR END OF LINE TO NEXT DEVICE DR END OF LINE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE NICE OR POKER SOURCE fDATA IN (-) > DATA IN (-F) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 30D-4000 FT IN WHEN USED IN CONJJNCTION TH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL ma SCALE TO NEXT DEVICE > ( ) DATA OUT (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID -- CEILING HARD LID -7\ . ------SPEAKER SUPPORT BRIDGE ------ 4' SQUARE. DEEP BOX -- WITH 1-1/2' EXTENSION --- CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKER/STROBE MOUNTING (DROP CEILING) SCALE:NONE - JUNCTI❑N BOX MOUNTED ON \ CEILINGI FLEX \` JUNCTI N BOX ------� MOUNTED AGAINST CEILING S PPORT SMOKE DETECTOR ----- SMOKE DETECTOR MOUNTING SCALE:NONE T O O TO NEXT DEVICE / / / / -----CADDY BAR SUSPENDED ILLUMINATED CEILING Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved W y :514 TEL. (206) 622-6545 RELEASE/REVISIONS DESCRIPTION LU I- Q 0 \ In Ii) <«< co co CC Q LLwccp mow= C.) cc = uw wcf 0 w tlt� 04. II� 1— /SCALE: — z z 0 0 z 0. z _J 1-- LL! ' ALE: 1/8"=1' DRAWN BY: I.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: �OB : NUMBER: 54542 % SHEET FA -02 , EOL—S1 20.09V X P2I N < Iv) LI_"* -1 2S,2 1 0 ITT • .! ! • ‘.! • I ' • IL. ['AC 3 0 MI •i •i' r-. ; . I \ t--"" 2I D,I L. L \ 0 111 30 /' i\ 1 I 2S,2V / I MI 0 75 L -1 VA- 1 -• • : 0 SELECT COMFORT WESTFIELD SOUTHCENTER MALL SCALE 1/814 /Th ---. ; FLAG NODS: • FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE, FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNIT SXSEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. • • I . f 1743 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NVI DESCRIPTION SHOP DRAWINGS FOR AHJ LIJ 1.-- < CO 0 ,..... in in 0 0 0 co CC DILL 133 0 2 § za) w fro llj z z w -±- cn <1.3- Lij 0 CC Ci)5 (/) ggp w • F- cr cc /S-CALE: 1/8"=1' DRAWN BY: !ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: :'; , .t.JOB NUMBER:54542 fl,• - ie:: SHEET • !':;' 1:i..,. ;,!'- Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved- . FA -03 } I- NORDSTROM t A 1 ' Vv ;AGE _EPS P.AREL'11ERIE EBNC:i%AS1 .- C)-I_I I)C• NORTH -1 SELEC R EiIAGIO �JLj <S ELE ; 1'=1 VEERIZON WIRELE..) MADE N WASHINGTON SPENCER GIFTS r:RASH Ss, C C.) m T v PIJ ?C ;C;RR. ELEC' lij --7 j arc.- 1 i'1' M ALL OFFICE MAL GFFICE SELECT COMFORT WESTFIELD SOUTHCENTER MALL _ _ _ SCALE 1132'4 30 C 15 C 30 C 75 C EOL -S1 20.09V RISER DIAG EX SYSTEM CALCULATIONS ATTERY SIZING CALCULATION Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: SELECT COMFORT Date: ;May 7, 2008 ;Wire Resistance 1.62 CURRENT TOTAL=.435 CIRCUIT: S1 QTY 0 0 DEVICES= Device Type SET -MC @15CD SET -MC @30CD :SET -MC @75CD 1SET MC @110CD .__.. `SET-HMC-C@115CD :SET-HMC-C@177CD SET -HMC @135CD SET -HMC @185CD Z-MC@15CD Z-MC@30CD SET-MC-CW@11 OCD ;Alarm Current; Alarm Total Wire Size 641 98! 1961 1751 1.75 2331 0 3181 0 4451 3181 445 641 64 981 0 Wire Length Voltage at EOL Circuit Total •;Total Wire Resistance (R ) (WL*2)*(R/ft)_...._..__.___ :Total Device Load, Amps (I) (Total Cct Load) 2333 Of TOTAL m A=' 4351 12 ` 220 20.089932 _ Notification Appliance CircuitDetail PROJECT:'WESTFIELD SOUTHCENTER MALL Panel: SELECT COMFORT Date:: May 6, 2008 CIRC.UIT:=SPEAKERCIRCUIT QTY Device Type ;Alarm Currentl Alarm Total Wire Size Wire Length 70.7V1/8 435 Voltage Drop (E ) (E= I * R) EOL Voltage (20.4-E) Wire Resistance 2.58 CURRENT TOTAL=15.4 Voltage at EOL Circuit Total 0.44; 0.31; 20.09 !Total Wire Resistance (R ) ( WL * 2 )*(R/ft)..__. ;Total Device Load, Amps (1) otal Cct Load) !Voltage Drop (E (E=I*R) EOL Voltage (20.4 - E) 1.14, 0.01; 0.01 20.391 20.39386992 5.4 VOLTAGE DROP CALCULATION rr ") CO 0' z 0 z_ cnuJ w cn 0 1743 IST AVE. 0' 0' • N 0 TEL. (206) 622-6545 RELEASE/REVISIONS C1) w z DESCRIPTION SHOP DRAWINGS FOR AHJ LU 11) In J i'- cco o <°)W.W �z oco cn D 2 w= <�� WQ - W mac_ W� CC w z w C) z 0 J 0 w C!) >- C1) 6ALE: 1/8"=ls DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER:54542 SHEET FA -04 SELECT COMFORT - - SELECT COMFORT FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations Current Load: Standby: Alarm: Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 AD2-P 1 0.0635 0.0635 0.064 0.064 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R HTRI-D ICP -B6 2 0.009600 0.0096 0.021 0.042 SET -MC @15CD SET -MC @30CD SET -MC @75CD SET -MC @110CD SET HMC-C@115CD SET HMC-C@135CD SE -T4 -1 -MC -C@185 -CD ZR -MC @15CD ZR -MC @30CD HCP 0.064 0.001600 0.0035 2 0.098 0.196 0.005 1 0.175 0.175 0.233 0.318 0.318 0.0731 Amps 0.106 Amps 0.445 1 0.064 0.064 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours 0.098 0.0015 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.03 Amps 0.465 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.465 Amps For 5 Minutes= 0.039 Amp -hours Total System Current Load: 2.204 Amp -hours 25%.Derating= 0.949 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: - 0.949 Amp -hours I Battery Pair to be Used: 12VDC Amp -hours 7AH ATTERY SIZING CALCULATION Notification Appliance Circuit Detail PROJECT: WESTFIELD SOUTHCENTER MALL Panel: SELECT COMFORT Date: ;May 7, 2008 ;Wire Resistance 1.62 CURRENT TOTAL=.435 CIRCUIT: S1 QTY 0 0 DEVICES= Device Type SET -MC @15CD SET -MC @30CD :SET -MC @75CD 1SET MC @110CD .__.. `SET-HMC-C@115CD :SET-HMC-C@177CD SET -HMC @135CD SET -HMC @185CD Z-MC@15CD Z-MC@30CD SET-MC-CW@11 OCD ;Alarm Current; Alarm Total Wire Size 641 98! 1961 1751 1.75 2331 0 3181 0 4451 3181 445 641 64 981 0 Wire Length Voltage at EOL Circuit Total •;Total Wire Resistance (R ) (WL*2)*(R/ft)_...._..__.___ :Total Device Load, Amps (I) (Total Cct Load) 2333 Of TOTAL m A=' 4351 12 ` 220 20.089932 _ Notification Appliance CircuitDetail PROJECT:'WESTFIELD SOUTHCENTER MALL Panel: SELECT COMFORT Date:: May 6, 2008 CIRC.UIT:=SPEAKERCIRCUIT QTY Device Type ;Alarm Currentl Alarm Total Wire Size Wire Length 70.7V1/8 435 Voltage Drop (E ) (E= I * R) EOL Voltage (20.4-E) Wire Resistance 2.58 CURRENT TOTAL=15.4 Voltage at EOL Circuit Total 0.44; 0.31; 20.09 !Total Wire Resistance (R ) ( WL * 2 )*(R/ft)..__. ;Total Device Load, Amps (1) otal Cct Load) !Voltage Drop (E (E=I*R) EOL Voltage (20.4 - E) 1.14, 0.01; 0.01 20.391 20.39386992 5.4 VOLTAGE DROP CALCULATION rr ") CO 0' z 0 z_ cnuJ w cn 0 1743 IST AVE. 0' 0' • N 0 TEL. (206) 622-6545 RELEASE/REVISIONS C1) w z DESCRIPTION SHOP DRAWINGS FOR AHJ LU 11) In J i'- cco o <°)W.W �z oco cn D 2 w= <�� WQ - W mac_ W� CC w z w C) z 0 J 0 w C!) >- C1) 6ALE: 1/8"=ls DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/05/08 BACKROUND PLAN PROVIDED BY: Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER:54542 SHEET FA -04 SELECT COMFORT VICINITY MAP (Suite# 436) SCALE: NTS General Notes 1. Western States Fire Protection to add new pendent heads new u ri ht heads and branchlines in new tenant space. Sprinklers in the new store shall be spaced in accordance with Nt-PA #13 Ordinary hazard Occupancy with 130 ft2 maximum spacing (.20 density used in calculations) FlexHead Brand flexheads will be used to pipe heads to -ceiling (equivalent length included in calculations). 2. The building is constructed with non-combustible materials and qualifies as unobstructed construction. 3. All hanger assemblies shall be spaced and installed in accordance with NFPA & manufacturer's specifications. 4. Branchline and arm -over pipe is black Schedule 40ipe.: 5. All new threaded fittings are cast iron class 125 or ductile iron class 150. 6. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with FPA, as well as state & local codes. 7. he owner is responsible for the freeze protection of all sprinkler system piping and components at are of designed tor freezingconditions. 8. xisteng tire spriftler system to emain. Western States Fire Protection will modify the existing system on1 in the areas.ofwork. All other areas are not in contract and WSFP is not responsible for existing conditions. WEST RISER DETAIL HYDRAULIC REFERENCE ONLY NOT TO SCALE Ordinary Group 11oO.2Ogpmlft2 for 9 ! 5.00ft2 2X4 CEILING TILE 12'-0" AFF BRANCHLINE (TYP.) 12'-6" AFF GYP BD CEILING 10'-0" AFF GYP BID CEILING 1(Y-0" AFF 1%1/4\ 102 R1 -EM 0 SPRINKLER MAIN (TYP.I, 12'-6" AFF 6-11 NOTE:\PPROVIDE SPRINKLER HEA Q \PIN CAVATIES (TYP) \\ GYP BD SOFFIT 10'-0" AFF R1 -NL 0 R2 0 T (3) T1 (9 GYP BD CEILING 8'-0" AFF GYP BD CEILING 10'-0" AFF EXISTING WELDED OUTLETS • GYP BD SOFFIT 9'-0" AFF Baa lawasommoomatossessomeasmow NOTE:\PPROVIDE SPRINKLER HEAD \PIN CAVATIES (TYP) NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping rior to hydrostatic test provai. GYP BD SOFFIT 10'-0" AFF • FIRE SPRINKLER PLAN FUKWILA FIRE DEPARTMENT, Please call: 575-440Z and give this job lea. — — I(e,, *;'d rjxact address for shut, ').it/.'n or r4-stdration approve,: f� t D TYPICAL FLEXABLE SPRINKLER CONNECTION;; FLEXHEAD SPRINKLER BRANCHLINE LEXABLE CONNECTING HOSE. • :'.:':..: IN STANDARD LENGTHS SUSPENDED T -BAR GRID CEILING TILE SPRINKLER HEAD FLEXHEAD DETAIL NOT TO SCALE FIG. 909 AI SWIVEL BRACE FITTING Nir BRACE PIPE FIG. 1000 (2 13/4-+EMBiED PENGTH) "FAST ��) SWAY RAMC ATTACHMENT NLINE PIPE LATERAL LINE RESTRAINTS NON -THREADED BRACE PIPE SELECT COMFORT Remote Area: Retail # 436 CALCULATION DESIGN CRITERIA: STANDARD NFPA #13-2007 OCCUPANCY CLASS ORD HAZARD 11 MAX. COVERAGE per HEAD 130 DENSITY .20 GPM FP for 945 SPRINKLER Reliable Model G4A Ft' ORIFICE 1t2'l lc- 6.6 WATER FLOW INFORM/zTON% STATIC 14u PSI RESIDUAL 20 PSI FLOW 10900 GPM AT BASE OF RISER, SYSTEM REQUIRES: 277.21 GPM (f457.62 ' fPSI ,.^ Yj T [, 'At time of Design 12'-6" CLG =37%a AREA REDUCTION Without Comments As Noted In Red Per The Attached Letter I nese plan have l: =:"_ r: I..:.. t;y ri- Tulcvii!a Fire Prevention Bum.-!.., current city standards. !a omissions standards and adequacy o` Additions, d: :: this date, will V. "• 'ii. 'C`. `,' i G'/rl1 i/ CLIVI i resubmittal of .,,utg t /ytl ill: 019prt1v-i. and . i„,F cns of adopted .:nc I; t, for the deoignor, drew1irlfr+ <+iityr Final accopt::ncr: I .;; ; :',f~al�ld ih � � �,,ti n gF t� , 1The Tukwila Fura,i�t_.,.. Date: 3l1 0' 2' 4' Scale: 114” = 1'-0" 8' 12' FIG.4 PIPE CLAMP FOR SWAY BRACE OLATERAL BRANCHLINE RESTRAINT NON -THREADED BRACE PIPE (2 13/1.IED LENGTH) FIG. 909 NO -THREAD SWIVEL SWAY BRACEATTACHME i BRACE PIPE LATERAL BRANCHLINE RESTRAINT NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt III Cut Rod Lgth Rounded to Nearest Inch Rod Coupling —` All Thread Rod Swivel Ring \ Concrete Construction Bottom of Concrete to Cantor Line of Pipe Note on Plan Note on Plan: Hanger Number and 'A' Dimension HANGER DETAIL NOT TO SCALE VICINITY MAP DETAIL NOT TO SCALE 2008 Tukwila Fire zs -77 Select Comfort 0 Andrew Chance Timberwolff Construction SYMBOL LEGEND REVISIONS Sprinkler Legend 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYM. SIN QTY SPRAY ORIF. FIN TEMP. MFR./MODEL APPROVAL: City of Tukwila 4 -WAY EARTHQUAKE BRACE 2 5.6 Upright '/z' Brass 155°F 1 HYDRAULIC REFERENCE POINT 15 5.6 Pendent 12" Chrome 155°F CONT. NO.: KS0330 HANGER SYMBOL Total = 17 DRAWN BY: Andrew Chancellor BRANCHLINE RESTRAINT • SPRK. ON SHEET: SEE LEGEND SPRK. ON JOB: DATE: 04/30/0$ Western States Fire Protection Company 7102180th AVE NE, STE A-105 - REDMOND, WA - 98052 Lic. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY -OFFICES LOCATED ALBUQUERQUE /AUSTIN !DALLAS / DECATUR / DENVER /DULUTH /HOUSTON /KANSAS CITY LAS VEGAS IMINNEAPOUS/ PHOENIX / PORTLAND !RAPID CITY/ ST. PALL /SALT LAKE CITY !SEATTLE Phone: 425.881.0100 Fax 425-881-3030 Select Comfort p4p 1006 Southcentner Mall Tukwila ,WA 98188 FIRE SPRINKLER PLAN SHEET FP -1 OF 1