PP - 211 SOUTHCENTER MALL - EXCALIBUR CUTLERY & GIFTS - PERMITS AND PLANS
211 SOUTHCENTER MALL ASSOCIATED PERMITS 13-F-224 12-F-063 13-S-195 12-S-051 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 211 Southcenter Mall, Space 636, Tukwila, 98188 Suite Number: 9202470010 Floor: Tenant Name: Aveda New Tenant? H- Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 E-mail Address: kveliz@guardiansecurity.com City State Zip Fax Number: 206.628.4990 Total number of new/relocated devices or sprinkler heads: 8 Valuation of Project (contractor's bid price): $ 1400. Scope of Work (please provide detailed information): Adding 8 devices to existing FRCP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O NER ORAUTHORIZ D it GENT: Signature: �✓.�-/ ./ Date: g �� Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doe 1/2/13 TFD FP Form 8 444111144 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 2.1 50U-lietCe124Cr J77cjJ% Tenant Name: PAID ��013 TUKWWIRE King Co. Assessor's Tax No.: Suite Number: (00 Floor: New Tenant? T Yes ❑ - No Property Owner's Name: \ \---S—\r rr �- (� •ral Mailing Address: V City State Zip CONTACT PERSON -if there are questions about the submittal. Name: SsvcA •oh,nso-1 Day Telephone: 6 -4/0 76 9' Company Name: arb W /'1 Pre ?rola-JAW, //7C POI & X /2//3 /29, // Creek, WA- 9? City State Zip E-mail Address: I r • / Fax Number: 7Z�• 4.13 1 Mailing Address: Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ f f Scope of Work (please provide detailed information): geloca+e (g) heads art! add C2J homds PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0ER OR/A1UTHO D AGENT: Signature:(7e.47l�Q' Print Name:jfJ 9d%/? ) ' Day Telephone: 4/'V -/e! •7C49 Date: as • 3 Plan Permit App.doc 1/2/13 TFD FP Form 8 MERE SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: W% Site Address: Z t PlAit�2►u,l�, Suite Number: Floor: Tenant Name: EX CA. i'r New Tenant? ® - Yes ❑ - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: [�e�et�r Q Day Telephone: (Sok) 3541 12.68 Company Name: Mailing Address: ‘s' S A T 1 W1i ( g‘ 3 City State Zip E-mail Address: r Nzs1 S e 3kei J Q i c Se L- k. c o' v Fax Number: (-2'0t) l x`t g Valuation of Project (contractor's bid price): $ .3o o Scope of Work (please provide detailed information): A t 111 o a.6 A la., ,..4" c1_&. ' i c Q.i sfiibi5s ;ys��, epc PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: �ae6e rt Ki Plan Permit App.doc Z®9 Date: O 3% �7J/ 1 i Day Telephone: (?-06 26,8 5/14/10 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Vacant Mall Space 211 Southcenter Mall Permit No.: 12-S-051 Date: March 14, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. EXISTING EXHAUST FAN, SEE M-DWGS. SERVICE CORRIDOR SURFACE MOUNTED LIGHT TRACK ABOVE LOW CLG., SHOWN DASHED UNDER -SHELF LIGHT FIXTURE GYP. BD. CLG. @ 9'-0" AFF @ CLOSET MILLWORK FIXTURES BELOW SHOWN DASHED, TYP. SALES FLOOR (HIGH CLG.) 12'-0" RETAINER STRAP WHERE REQUIRED IN SEISHIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS ADJACENT TENANT THE ART OF SHAVING ENTRY SOFFIT GWB (P-7) TRACK 3' f"L SURFACE MOUNTED CURTAIN TRACK, CENTER BETWEEN MILLWORK -FIXTURES BELOW GWB (P-7) EQ. EXISTING CLG. ELEMENTS IN TOILET RM. TO REMAIN EXISTING WALL MOUNTED LIGHT FIXT.- TO REMAIN MECH. UNIT ABOVE SHOWN DASHED, SEE DETAIL 2 FOR SEISMIC BRACING DETAILS EXISTING WALL MTD. EXIT SIGN W/ EMERGENCY LIGHTS SEE SHEET FP1.0 FOR SEMI -RECESSED SPRINKLER HEAD LAYOUT IN BACK OF HOUSE RELOCATED FIRE ALARM STROBE, TYP. Without Comments p As Noted in Red E3 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance ar,J Mil require a resubmittal of revised drawings for suosequent approval. Final acceptance is subject to field test and Inspection b; The.Tukwila Fire Prevention Bureau. STOCK ROOM 10'-5 1/2" SURFACE MOUNTED LIGHT TRACK @ HIGH CLG., TYP. RECESSED CLG. TROUGH W/ SURFACE MOUNTED LIGHT TRACK ACT -1 SUPPLY AND RETURN AIR GRILLES / RECESSED INDIRECT WALL WASHER, LOCATED IN GWB FASCIA ABOVE, CENTER ON MILLWORK FIXTURE SEE M -SHEETS BELOW, MOUNT SO LAMP SIDE IS CLOSER TO WALL REFLECTED CEILING PLAN. SCALE:, 3/8" = 1'-0" Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart O 8 — Relocate Reliable Model G5-56 165° Standard Response Pendent 1/2 x 1/2 (concealed white) ® 2 — Add Reliable Model G5-56 165° Standard Response Pendent 1/2 x 1/2 (concealed white) ® E — Existing no change ADJACENT TENANT L., 'UKWILA FIRE DEPARTMENT `lease call 206-575-4107 and gives l=ire Permit No. and exact address for shut- down or restoration approval. CROWN FIRE PROTECTION IINCORF JRA TED. P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7689 KEY PLAN AVEDA Space No. 636, Level 1 Aveda 211 Southcenter Mall Space 636 Tukwila, WA DATE:a;L.p . DRAWN: ' SCALE: 31-e 2" Without Comments O As Noted in Red O Per The Attached Letter These plans have been re•, ewed by The Tukwila Fire Prevention Bureau for ccj.-1i'orrn nce with current City sta-ndards. Act pta ice is s{!ticsi to errors and omissions which do not authorize vioiaticns of adopted standards and ordinances. The. r :s T:,'nsibility for the adequacy of des:gn resits totaiiy v.',I.71 cr;e designer. Additions, deietili is or to ritC:S:? (irr'vings after this date vriil void this accc,)tanu: -1> to L1,!!! + :::ouire a resubrulttal of revised drawings for suosequent approval. Final acceptance Is suhl'ct to field test and inspection by The Tukwila Fire Prevention Bureau. Date: By: I I SHEET NUMBER NOTICE A completed, signed, Tukwila, Fire Department Pre-test Certificate must be presented, to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. 11-F- 2�L1 and exact address for shut- down hutdown or restoration a SHEET TITLE 11 FIRE ALAR FA -01 SYSTEM I\FOMATION FA -02 TYPICAL WIRING A\D v1OUNTING DETAILS FA -03 SYSTEM CALCULATIONS A D SINGLE LINE DIAD AM FA -04 FIRE ALARM SYSTEM PLA\ SHEET INDEX WIRE SCHEDULE A\D CO\DUIT FILL CHA RT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION UK V SYSTEM ,' DDITION ILA, SIIINGTON A FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE VATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. • 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.=.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX EX 1 1 2 3 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND .`11 NORDSTROM , /, 3 LEVE; S 171,275sf 8 E-9ESS3 macys 4 LEVELS 250, rs' w7E". N'et,ts VA, .�� (. 1 CLAP E S L iSNEY SI^ t AVEDA #211 / SPACE #636 SITE PLAN SLrE h Gan s GAT WSiAt:n TGKVU T}R0 [4.10.,Y; SS 8 E%STIkG JCPenney 3 LE,.ELS 276.4680 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 w rr w w J W Ch REV. BY: DMG z 0 r= a_ EE U cnw 0 SHOP DRAWINGS Ili I - a 0 09/16/13 2CCCCa 111 (0 M co Z wco coo p U .- F- o�Z < O 2QJz 0w�Z `W w' ©Ccc w w� CC LL T N PAID SEP 18 2013 TUKWILA FIRE c‘ SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/16/13 BACKROUND PLAN PROVIDED BY: Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE IMIH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60NZ �I DEDICATED BER NCY l NOTE FOR ADpnONN. SPEC CAPONS SEE PRODUCT DOOIIENTATWN. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC TAI F*.4 •r: r* TO NEXT ADDRESSABLE (+ DEVICE STIP IF LAST DEVICE FROM XLS CONTROL PANEL (+ OR PREVIOUS ADDRESSABLE DEVICE C Llk)21 ORD N LL CD0 El 0 0 00 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (—) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIRWITH SHIELD #18 FPUFPIR RED (JACKET) *CONTACT RATINGS 4.OA 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O r GROUND L —) 1:0 I HTRI—R 114 r -I (+)> TO NEXT DEVICE OR (—) > STOP IF LAST DEVICE DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL PAD -3 GROUND NPUT NPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1— 1 2+ 2— 2 NC C NO + — + — + — + — + — NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C—CABLE C—CABLE (-) (+) SPARE ( SPARE ZSPARE (-) n v HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERATURE: +32'F(0'C) TO 100F(38C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR , -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE r DATA IN (—) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR — / DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE / STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING >TONEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT SMOKE/HEAT DETECTOR -�EJJ TO NEXT DEVICE CADDY BAR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 TEL. (206) 622-654.5 RELEASE/REVISIONS REV. BY: I 0 M 0 DESCRIPTION SHOP DRAWINGS DATE M \ c0 rn 0 2I<<<<< rSCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/ 16/ 13 BACKROUND PLAN PROVIDED BY: 'OB NUMBER: 6162-1i %- SHEET FA -02 FRCP ADS" Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096, 0.021 0.042 0.0731 Amps 0.106 Amps EXISTI G SIE naI en ane :1J C Current. Load Marin Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW 15CD 9 0.0875 ZH-MC-CW ©30CD al -MC -CW @75CD al -MC -CW @95CD ZH-HMC-CW @115CD IZR-MC-CW @15CD 13 0.131 6 0.222 2 0.292 0.584 0.371 12 0.069 0.828 ZRC-15CD 0.064 0.03 Amps 1.442 Amps Standby Current Load: 0.03 Amps For 24 Hou 0.720 Amp -hours Alarm Current Load:. 1.442 Amps For 5 Minutes= 0.121 Amp -hours 25% De rating= 1.051 Amp -hours Total System Current Load: 1.051 Amp -hours 12VDC An -hours TO NEAREST EXISTING POWER SUPPLY SYSTEM CALCULATIONS 6 S 2S 2S 2S 2S 26 LI S1-1 S1-2 S1-3 S1-4 15cd 15cd 30cd 30cd TO NEAREST EXISTING DATA LOOP D EOL S1 PROJECT: Panel: Date: Notification Appliance Circuit Detail AVEDA EXISTING PAD -3 POWER SUPPLY September 16, 2013 Wire Resistance 2.58 CURRENT TOTAL=1418.00 b (HT•R D,I 1 214 TSM HT -R 171 -MC -CW_ ,©15cd_2 ZH-MC-CW ©30cd 7}1 -MC -CW @75cd ZH-MC=CW @95cd 71 -1 -NIC -CW @115cd...,___. C -CW @15cd 1 DEVICES 87 131 222: 292 371 69 87 262 0: 0 0 TOTAL mA 418i Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E ) EDL Voitage • 14 189 • 23.591 418 (WL*2)*(Rift) i Total Cct Load) (E= 1 * R) 24-E): 0.98, 0.42' 0.41 23.59 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX. OD 0' 0 z L1.1 W W • u J w Lu Q I-- CJ) (NJ tr) • w FAX (206) 628-4990 RELEASE/REVISIONS IREV. BY: I 3 0 DESCRIPTION SHOP DRAWINGS DATE 09/16/13 2 ««< L T CV CC 0 w z w J 0 z CD z C/) z SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/16/13 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM JOB NUMBER: 6162-1} SHEET FA -03 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP SERVICE CORRIDOR D 0- ACCES;i y TOILET r'+. STOCK ROOM S1-1 f - � (1j a V 4D EOL S1 HT -R HT -R TSM J RF (f i 1 S1-3 30cd S1 Vf 51-2;=-J Y 1 f 15cd / f It e I n'n p r L FN -2 FN -2 z SALES FLOOR 0' v AD:;ACENT TENANT THE ART OF SHAVING 4-s —16)W-1 1(2LU-1 i FIRE ALARM SYSTEM PLAN 2S — I ADJACENT TENANT FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX. Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved W y FAX RELEASE/REVISIONS IREV. BY: I O 0 DESCRIPTION SHOP DRAWINGS DATE M (D O O co CO co z W co p U O) D �z Quo Q w,�z W cWCC wc Q W CC T T CV } N 4-CALE: 1/4" =1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/16/13 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 6162-1.) 1 SHEET '. FA -04 �, i X CA LI B FIRE ALAR UK SYSTE UTLERY DDITION ILA, `:'. ASHINGTON SHEET NUM 3E SHEET TITLE FA -01 SYSTEvA INFORMATION FA -02 TYPICAL WIRI\G AND MOUNTING DETAILS FA -03 SYSTEIV CALCULATIONS AND SII\ G LE LINE D IAG RAN FA -04 FIRE ALAR V SYSTE V PLA\ SHEET INDEX 12C W:trhout Comments Q As Noted iri Red E3 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Atceptance is subject to errors and omissions which oo rot authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these- drawings after this date will void this eccepta►rce and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is sub pct to field test and Inspection by The Tukwila Fire Pie'venticn 3ureau. Date: L = r' �' _F . NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the tstir a. TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No., 1� -F-043 z nd exact address for shut- down or restoration 4-p provai. D U LE A\D CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPUFPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.0. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT ❑F ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NEPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 2 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD -3 -ENOL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1 G RING CEILING ® D DUCT DETECTOR AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM it 3 LEVELS 171,275sf x P.MAY.71,791 macys 4 LE Etc 250.40'sf TIE RAW 4J'Z p`:r,Lva ❑ ❑ C_9N. A•h .:c qua ..:Myst 2sch Ctto in:_.rte, s I I .:•m �'� s EXCALIBUR CUTLERY #211 / SPACE #636 10K r..1 •nese 0 VSs 7471-- I;' JCPenney PAID MAR 29 2012 TUKWILA FIRE i.a FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: C0 m 0 DESCRIPTION SHOP DRAWINGS DATE N 00 0 M 0 2 aaaaa (0 C) (0 cce Lizwco JO 0 b-0_0) F- 0 ci)l)Q wiz CC D- W CC¢LU T T N 0 cc us. 0 N } N SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/29/ 12 BACKROUND PLAN PROVIDED BY: k ..10B NUMBER: 55430 1n WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2012 by Guardian Security S stems, Inc. All Ri•hts Reserved SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6011Z �j DEDICATED EM GENCY 111 NO1E FOR AD01110NAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 'CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC PLIfid5MENBAG" m NEXT ADDRESSABLE 0+ DEVICE STOP IF LAST DEVICE - MN XLS CONTROL PANEL a DR PREVIOUS ADDRESSABLE DEVICE O 0 0 c 0 HTRI—R 0 O 0 NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 I J 0000 U 11 0 PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - 0 Oa 0 0 0 0 0 0 3.6k EOL (-) (+) (-) (+) SPARE SPARE , SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C7 v S z S z m o --i m m 13' 'A N O 0 Nm o m r v (-)(-) (+)(+) (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPUFPLR RED (JACKET) *CONTACT RAINS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O r., HTRI—R 0 o GROUND 4 0 0 0 0 114 e (+)> TO NEXT DEVICE OR (-) STOP IF LAST DEVICE DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY U � HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +302*FF(0C)TO100F(338C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —\ -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR i--- DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE / STR❑BE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX 17) /11"..W"" JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 TO NEXT DEVICE CADDY BAR D1 SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL co 1:7 W y a 174 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 03/08/12 2 aaaaa M > z CO C OwcO a. 0) i-F(9,,F) W z F¢ °CO151Q W LLQ~ us) J CD Z 0 0 z c� z 0 87. SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/29/12 BACKROUND PLAN PROVIDED BY: 'OB NUMBER: 55430 I. SHEET FA -02 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps AL R CUT EXISTING SIE N P+ i ,�►1�--��'gnal;Ex ender PaneBatt aa'GaIcua n� DESCRIPTION SHOP DRAWINGS Current Load: '; : , Stalndby; : ` Alarm: 03/08/12 z aaaaa Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 Zi -MC -CW @15CD 9 0.0875 71 -MC -CW @30CD 12 0.131 ZH-MC-CW ©75CD 6 0.222 ZH-MC-CW @95CD 2 0.292 0.584 ZH-HMC-CW @115CD 0.371 ZR -MC -CW @15CD 12 0.069 0.828 ZR -MC -W @15CD 0.064 0.03 Amps 1,442 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.442 Amps For 5 Minutes= 0.121 Amp -hours 25% Derating= 1.051 Amp -hours Total System Current Load: 1.051 Amp -hours Eiattery Pairl to:be..Use d 12VDC Amp-hoWa 7 2 ►H Notification Appliance Circuit Detail PROJECT: EXCALIBUR CUTLERY Panel: PAD -3 BPS Date: j March 1, 2012 !Wire Resistance 2.58 CURRENT TOTAL=1422.00 !ZH-MC-CW @15cd ZH-MC-CW ©30cd 1 1ZH-MC-CW @75cd ZH-MC-CW @95cd 1ZH-MC-CW @115cd 1 ZR -MC -CW @15cd DEVICES 3 _87 131 222 292 371; 69 TOTAL mA=l jTotal Wire Resistance (R ) Total Device Load,Amps (i) Volta ge Drop ( E) I EOL Voltage 0 131 222 0 01 69 422( 14 189 23.591 422 (W L * 2) * (R/ft) (Total Cct Load) (E=1*R) 24-E) 0.98 0.42. 0.41; 23.59 SYSTEM CALCULATIONS TO NEAREST EXISTING �sl �C J, b E., EOL POWER SUPPLY Si S1-1 S1-2 S1-3 15cd 30cd 75cd TO NEAREST EXISTING DATA LOOP FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 03/08/12 z aaaaa C) >s- co cc z w co J~gm W o(nz d J° CJ - Cr CC �z5 < <m— rrUi t.l.!LL"T T CV or 0 0 w z LU z 0 z C/) z O ✓ J 0 U) 'GALE: NOT TO SCALE~ DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:02/29/12 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM JOB NUMBER: 55430 1 SHEET FA 03 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved G. R C =RID \-MALL COMMON AREA —\ LEASE LINE 11, s'-0° LEASE LINE L EXISTING ADJACENT TENANT S?ACE NO WORK THIS AREA ca in O' -O" EOL S1 RETAIL BACK R✓CM IEI HT -R TSM TO NEAREST EXISTING POWER SUPPLY 2 S1-1 y-�( 15cd 1%-1\ RES ROOM S1-2 30cd ALU 1 NUV STOREFRONT WITH GLAZING TO NEAREST EXISTING EXISTING/ OP 1-IOUSE -C NO WORK THIS AREA - D E) NEUTRAL BIER TO REMAIN OUTLINE OF EXISTING SULK -IEA D A>=OvE cst to LEASE LINE EXISTING ADJACENT TENANT SPACE NO WOK T1 -IIS AREA (E) ELECTRICAL PANELS TO REMAIN LEAS- _INE FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Prorietar and Confidential, Co • ri. ht 2012 b Guardian Securit S stems, Inc. All Ri • hts Reserved 1743 1 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 DESCRIPTION SHOP DRAWINGS W 1-- Q 0 03/08/12 0 CU *co Wz Liu 0 0 0, F. E O) E ci)Z CC I (/) 14) C w<4:cm� 0 tuilis W � �~ T N WLL `�CALE: 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/29/12 BACKROUND PLAN PROVIDED BY: .10B NUMBER: 55430 J SHEET '`/� FA -04 METAL STUD FRAMING AND GUL BULKHEAD AT 10'-e" AFP EXISTING ADJACENT TENANT SPACE NO WORK THIS AREA MALL COMMCN AREA t�1 r1 ALUMINUM STOREFRONT WITH GLAZING D • D N N l 1 OUTLINE CF EXISTING BULKHEAD ABOVE (E) FINS AT BULKHEAD. TO BE DEMOLISHED EXISTING ADJACENT TENANT SPACE NOWORK THIS AREA EXISTING BACK OF HOUSE - CORRIDOR NO WORK THIS AREA REFLECTED CEILING PLAN 1/4" = 1'-0" Design per NFPA 13, Ordinary Hazard All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 02 — Add Reliable Model G4 Standard Response Concealed White 165° Pendents 1/2 x 1/2 (Storefront) © 12 — Add Reliable Model G Standard Response Semi -recessed 165° Pendents 1/2 x 1/2 (sales and backrooms) 14 — Total TUKWILA FIRE DEPARTMENT MEr T Please call 206-575-4407 .arid give this Fire Permit No.:: -S v 1 and exact address for shut- down or res`oratibn approval. INRETSENE C AREASPWHERE REQUIRED TDP BEAN/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS 1N thout Comments t_7 As Noted in Red Per The Attached_ Luer These plans have been rev1.3wed by The Tukwila Fire' Prevention Bureau .fr;r cool of rn n;:e with current City. standards. Acce:;i nce is i:ubiect to errors and omissions Which do not aui;hc rine violations of adopted standards and ord r .c The responsibii;ty for the adequacy of desion ; :::`. totally with the designer. Additions, deletioris to these drawings after this date will void tit;_. • , :`eptartce and will require a resubmittal of revisu c e vii s r::;r subsecpent approval. Final acceptance is sub;ect to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 3---/r-1)- By: /<. 3 Site Plan CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Vacant Space 636 211 Southcenter Tukwila, WA PAID MICR 09 2012 TISK HILA FIRE DATE: 3 , 9 • 11. DRAWN: a p' SCALE: DPI 211 SOUTHCENTER MALL ASSOCIATED PERMITS 13-F-224 12-F-063 13-S-195 12-S-051 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 211 Southcenter Mall, Space 636, Tukwila, 98188 Suite Number: 9202470010 Floor: Tenant Name: Aveda New Tenant? H- Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 E-mail Address: kveliz@guardiansecurity.com City State Zip Fax Number: 206.628.4990 Total number of new/relocated devices or sprinkler heads: 8 Valuation of Project (contractor's bid price): $ 1400. Scope of Work (please provide detailed information): Adding 8 devices to existing FRCP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O NER ORAUTHORIZ D it GENT: Signature: �✓.�-/ ./ Date: g �� Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doe 1/2/13 TFD FP Form 8 444111144 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 2.1 50U-lietCe124Cr J77cjJ% Tenant Name: PAID ��013 TUKWWIRE King Co. Assessor's Tax No.: Suite Number: (00 Floor: New Tenant? T Yes ❑ - No Property Owner's Name: \ \---S—\r rr �- (� •ral Mailing Address: V City State Zip CONTACT PERSON -if there are questions about the submittal. Name: SsvcA •oh,nso-1 Day Telephone: 6 -4/0 76 9' Company Name: arb W /'1 Pre ?rola-JAW, //7C POI & X /2//3 /29, // Creek, WA- 9? City State Zip E-mail Address: I r • / Fax Number: 7Z�• 4.13 1 Mailing Address: Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ f f Scope of Work (please provide detailed information): geloca+e (g) heads art! add C2J homds PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0ER OR/A1UTHO D AGENT: Signature:(7e.47l�Q' Print Name:jfJ 9d%/? ) ' Day Telephone: 4/'V -/e! •7C49 Date: as • 3 Plan Permit App.doc 1/2/13 TFD FP Form 8 MERE SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: W% Site Address: Z t PlAit�2►u,l�, Suite Number: Floor: Tenant Name: EX CA. i'r New Tenant? ® - Yes ❑ - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: [�e�et�r Q Day Telephone: (Sok) 3541 12.68 Company Name: Mailing Address: ‘s' S A T 1 W1i ( g‘ 3 City State Zip E-mail Address: r Nzs1 S e 3kei J Q i c Se L- k. c o' v Fax Number: (-2'0t) l x`t g Valuation of Project (contractor's bid price): $ .3o o Scope of Work (please provide detailed information): A t 111 o a.6 A la., ,..4" c1_&. ' i c Q.i sfiibi5s ;ys��, epc PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: �ae6e rt Ki Plan Permit App.doc Z®9 Date: O 3% �7J/ 1 i Day Telephone: (?-06 26,8 5/14/10 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Vacant Mall Space 211 Southcenter Mall Permit No.: 12-S-051 Date: March 14, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. EXISTING EXHAUST FAN, SEE M-DWGS. SERVICE CORRIDOR SURFACE MOUNTED LIGHT TRACK ABOVE LOW CLG., SHOWN DASHED UNDER -SHELF LIGHT FIXTURE GYP. BD. CLG. @ 9'-0" AFF @ CLOSET MILLWORK FIXTURES BELOW SHOWN DASHED, TYP. SALES FLOOR (HIGH CLG.) 12'-0" RETAINER STRAP WHERE REQUIRED IN SEISHIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS ADJACENT TENANT THE ART OF SHAVING ENTRY SOFFIT GWB (P-7) TRACK 3' f"L SURFACE MOUNTED CURTAIN TRACK, CENTER BETWEEN MILLWORK -FIXTURES BELOW GWB (P-7) EQ. EXISTING CLG. ELEMENTS IN TOILET RM. TO REMAIN EXISTING WALL MOUNTED LIGHT FIXT.- TO REMAIN MECH. UNIT ABOVE SHOWN DASHED, SEE DETAIL 2 FOR SEISMIC BRACING DETAILS EXISTING WALL MTD. EXIT SIGN W/ EMERGENCY LIGHTS SEE SHEET FP1.0 FOR SEMI -RECESSED SPRINKLER HEAD LAYOUT IN BACK OF HOUSE RELOCATED FIRE ALARM STROBE, TYP. Without Comments p As Noted in Red E3 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance ar,J Mil require a resubmittal of revised drawings for suosequent approval. Final acceptance is subject to field test and Inspection b; The.Tukwila Fire Prevention Bureau. STOCK ROOM 10'-5 1/2" SURFACE MOUNTED LIGHT TRACK @ HIGH CLG., TYP. RECESSED CLG. TROUGH W/ SURFACE MOUNTED LIGHT TRACK ACT -1 SUPPLY AND RETURN AIR GRILLES / RECESSED INDIRECT WALL WASHER, LOCATED IN GWB FASCIA ABOVE, CENTER ON MILLWORK FIXTURE SEE M -SHEETS BELOW, MOUNT SO LAMP SIDE IS CLOSER TO WALL REFLECTED CEILING PLAN. SCALE:, 3/8" = 1'-0" Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart O 8 — Relocate Reliable Model G5-56 165° Standard Response Pendent 1/2 x 1/2 (concealed white) ® 2 — Add Reliable Model G5-56 165° Standard Response Pendent 1/2 x 1/2 (concealed white) ® E — Existing no change ADJACENT TENANT L., 'UKWILA FIRE DEPARTMENT `lease call 206-575-4107 and gives l=ire Permit No. and exact address for shut- down or restoration approval. CROWN FIRE PROTECTION IINCORF JRA TED. P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7689 KEY PLAN AVEDA Space No. 636, Level 1 Aveda 211 Southcenter Mall Space 636 Tukwila, WA DATE:a;L.p . DRAWN: ' SCALE: 31-e 2" Without Comments O As Noted in Red O Per The Attached Letter These plans have been re•, ewed by The Tukwila Fire Prevention Bureau for ccj.-1i'orrn nce with current City sta-ndards. Act pta ice is s{!ticsi to errors and omissions which do not authorize vioiaticns of adopted standards and ordinances. The. r :s T:,'nsibility for the adequacy of des:gn resits totaiiy v.',I.71 cr;e designer. Additions, deietili is or to ritC:S:? (irr'vings after this date vriil void this accc,)tanu: -1> to L1,!!! + :::ouire a resubrulttal of revised drawings for suosequent approval. Final acceptance Is suhl'ct to field test and inspection by The Tukwila Fire Prevention Bureau. Date: By: I I SHEET NUMBER NOTICE A completed, signed, Tukwila, Fire Department Pre-test Certificate must be presented, to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. 11-F- 2�L1 and exact address for shut- down hutdown or restoration a SHEET TITLE 11 FIRE ALAR FA -01 SYSTEM I\FOMATION FA -02 TYPICAL WIRING A\D v1OUNTING DETAILS FA -03 SYSTEM CALCULATIONS A D SINGLE LINE DIAD AM FA -04 FIRE ALARM SYSTEM PLA\ SHEET INDEX WIRE SCHEDULE A\D CO\DUIT FILL CHA RT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION UK V SYSTEM ,' DDITION ILA, SIIINGTON A FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE VATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. • 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.=.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX EX 1 1 2 3 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND .`11 NORDSTROM , /, 3 LEVE; S 171,275sf 8 E-9ESS3 macys 4 LEVELS 250, rs' w7E". N'et,ts VA, .�� (. 1 CLAP E S L iSNEY SI^ t AVEDA #211 / SPACE #636 SITE PLAN SLrE h Gan s GAT WSiAt:n TGKVU T}R0 [4.10.,Y; SS 8 E%STIkG JCPenney 3 LE,.ELS 276.4680 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 w rr w w J W Ch REV. BY: DMG z 0 r= a_ EE U cnw 0 SHOP DRAWINGS Ili I - a 0 09/16/13 2CCCCa 111 (0 M co Z wco coo p U .- F- o�Z < O 2QJz 0w�Z `W w' ©Ccc w w� CC LL T N PAID SEP 18 2013 TUKWILA FIRE c‘ SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/16/13 BACKROUND PLAN PROVIDED BY: Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE IMIH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60NZ �I DEDICATED BER NCY l NOTE FOR ADpnONN. SPEC CAPONS SEE PRODUCT DOOIIENTATWN. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC TAI F*.4 •r: r* TO NEXT ADDRESSABLE (+ DEVICE STIP IF LAST DEVICE FROM XLS CONTROL PANEL (+ OR PREVIOUS ADDRESSABLE DEVICE C Llk)21 ORD N LL CD0 El 0 0 00 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (—) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIRWITH SHIELD #18 FPUFPIR RED (JACKET) *CONTACT RATINGS 4.OA 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O r GROUND L —) 1:0 I HTRI—R 114 r -I (+)> TO NEXT DEVICE OR (—) > STOP IF LAST DEVICE DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL PAD -3 GROUND NPUT NPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + 1— 1 2+ 2— 2 NC C NO + — + — + — + — + — NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C—CABLE C—CABLE (-) (+) SPARE ( SPARE ZSPARE (-) n v HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL (+) HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERATURE: +32'F(0'C) TO 100F(38C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR , -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE r DATA IN (—) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR — / DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE / STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING >TONEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT SMOKE/HEAT DETECTOR -�EJJ TO NEXT DEVICE CADDY BAR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 TEL. (206) 622-654.5 RELEASE/REVISIONS REV. BY: I 0 M 0 DESCRIPTION SHOP DRAWINGS DATE M \ c0 rn 0 2I<<<<< rSCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/ 16/ 13 BACKROUND PLAN PROVIDED BY: 'OB NUMBER: 6162-1i %- SHEET FA -02 FRCP ADS" Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096, 0.021 0.042 0.0731 Amps 0.106 Amps EXISTI G SIE naI en ane :1J C Current. Load Marin Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 ZH-MC-CW 15CD 9 0.0875 ZH-MC-CW ©30CD al -MC -CW @75CD al -MC -CW @95CD ZH-HMC-CW @115CD IZR-MC-CW @15CD 13 0.131 6 0.222 2 0.292 0.584 0.371 12 0.069 0.828 ZRC-15CD 0.064 0.03 Amps 1.442 Amps Standby Current Load: 0.03 Amps For 24 Hou 0.720 Amp -hours Alarm Current Load:. 1.442 Amps For 5 Minutes= 0.121 Amp -hours 25% De rating= 1.051 Amp -hours Total System Current Load: 1.051 Amp -hours 12VDC An -hours TO NEAREST EXISTING POWER SUPPLY SYSTEM CALCULATIONS 6 S 2S 2S 2S 2S 26 LI S1-1 S1-2 S1-3 S1-4 15cd 15cd 30cd 30cd TO NEAREST EXISTING DATA LOOP D EOL S1 PROJECT: Panel: Date: Notification Appliance Circuit Detail AVEDA EXISTING PAD -3 POWER SUPPLY September 16, 2013 Wire Resistance 2.58 CURRENT TOTAL=1418.00 b (HT•R D,I 1 214 TSM HT -R 171 -MC -CW_ ,©15cd_2 ZH-MC-CW ©30cd 7}1 -MC -CW @75cd ZH-MC=CW @95cd 71 -1 -NIC -CW @115cd...,___. C -CW @15cd 1 DEVICES 87 131 222: 292 371 69 87 262 0: 0 0 TOTAL mA 418i Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E ) EDL Voitage • 14 189 • 23.591 418 (WL*2)*(Rift) i Total Cct Load) (E= 1 * R) 24-E): 0.98, 0.42' 0.41 23.59 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX. OD 0' 0 z L1.1 W W • u J w Lu Q I-- CJ) (NJ tr) • w FAX (206) 628-4990 RELEASE/REVISIONS IREV. BY: I 3 0 DESCRIPTION SHOP DRAWINGS DATE 09/16/13 2 ««< L T CV CC 0 w z w J 0 z CD z C/) z SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/16/13 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM JOB NUMBER: 6162-1} SHEET FA -03 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP SERVICE CORRIDOR D 0- ACCES;i y TOILET r'+. STOCK ROOM S1-1 f - � (1j a V 4D EOL S1 HT -R HT -R TSM J RF (f i 1 S1-3 30cd S1 Vf 51-2;=-J Y 1 f 15cd / f It e I n'n p r L FN -2 FN -2 z SALES FLOOR 0' v AD:;ACENT TENANT THE ART OF SHAVING 4-s —16)W-1 1(2LU-1 i FIRE ALARM SYSTEM PLAN 2S — I ADJACENT TENANT FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FIELD LOCATE TENANT JUNCTION BOX. Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved W y FAX RELEASE/REVISIONS IREV. BY: I O 0 DESCRIPTION SHOP DRAWINGS DATE M (D O O co CO co z W co p U O) D �z Quo Q w,�z W cWCC wc Q W CC T T CV } N 4-CALE: 1/4" =1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 09/16/13 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 6162-1.) 1 SHEET '. FA -04 �, i X CA LI B FIRE ALAR UK SYSTE UTLERY DDITION ILA, `:'. ASHINGTON SHEET NUM 3E SHEET TITLE FA -01 SYSTEvA INFORMATION FA -02 TYPICAL WIRI\G AND MOUNTING DETAILS FA -03 SYSTEIV CALCULATIONS AND SII\ G LE LINE D IAG RAN FA -04 FIRE ALAR V SYSTE V PLA\ SHEET INDEX 12C W:trhout Comments Q As Noted iri Red E3 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Atceptance is subject to errors and omissions which oo rot authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these- drawings after this date will void this eccepta►rce and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is sub pct to field test and Inspection by The Tukwila Fire Pie'venticn 3ureau. Date: L = r' �' _F . NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the tstir a. TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No., 1� -F-043 z nd exact address for shut- down or restoration 4-p provai. D U LE A\D CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPUFPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPUFPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.0. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT ❑F ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NEPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 2 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD -3 -ENOL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -1 1 BASE 4S DEEP W/ 1 G RING CEILING ® D DUCT DETECTOR AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S DEEP BOX CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM it 3 LEVELS 171,275sf x P.MAY.71,791 macys 4 LE Etc 250.40'sf TIE RAW 4J'Z p`:r,Lva ❑ ❑ C_9N. A•h .:c qua ..:Myst 2sch Ctto in:_.rte, s I I .:•m �'� s EXCALIBUR CUTLERY #211 / SPACE #636 10K r..1 •nese 0 VSs 7471-- I;' JCPenney PAID MAR 29 2012 TUKWILA FIRE i.a FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: C0 m 0 DESCRIPTION SHOP DRAWINGS DATE N 00 0 M 0 2 aaaaa (0 C) (0 cce Lizwco JO 0 b-0_0) F- 0 ci)l)Q wiz CC D- W CC¢LU T T N 0 cc us. 0 N } N SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/29/ 12 BACKROUND PLAN PROVIDED BY: k ..10B NUMBER: 55430 1n WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2012 by Guardian Security S stems, Inc. All Ri•hts Reserved SHEET FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6011Z �j DEDICATED EM GENCY 111 NO1E FOR AD01110NAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 'CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC PLIfid5MENBAG" m NEXT ADDRESSABLE 0+ DEVICE STOP IF LAST DEVICE - MN XLS CONTROL PANEL a DR PREVIOUS ADDRESSABLE DEVICE O 0 0 c 0 HTRI—R 0 O 0 NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 I J 0000 U 11 0 PAD -3 00 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - 0 Oa 0 0 0 0 0 0 3.6k EOL (-) (+) (-) (+) SPARE SPARE , SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) (-) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C7 v S z S z m o --i m m 13' 'A N O 0 Nm o m r v (-)(-) (+)(+) (+) 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FPUFPLR RED (JACKET) *CONTACT RAINS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. O r., HTRI—R 0 o GROUND 4 0 0 0 0 114 e (+)> TO NEXT DEVICE OR (-) STOP IF LAST DEVICE DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPEC FIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY U � HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +302*FF(0C)TO100F(338C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —\ -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR i--- DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /— HORN STROBE / STR❑BE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX 17) /11"..W"" JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 TO NEXT DEVICE CADDY BAR D1 SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL co 1:7 W y a 174 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 03/08/12 2 aaaaa M > z CO C OwcO a. 0) i-F(9,,F) W z F¢ °CO151Q W LLQ~ us) J CD Z 0 0 z c� z 0 87. SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/29/12 BACKROUND PLAN PROVIDED BY: 'OB NUMBER: 55430 I. SHEET FA -02 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps AL R CUT EXISTING SIE N P+ i ,�►1�--��'gnal;Ex ender PaneBatt aa'GaIcua n� DESCRIPTION SHOP DRAWINGS Current Load: '; : , Stalndby; : ` Alarm: 03/08/12 z aaaaa Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 Zi -MC -CW @15CD 9 0.0875 71 -MC -CW @30CD 12 0.131 ZH-MC-CW ©75CD 6 0.222 ZH-MC-CW @95CD 2 0.292 0.584 ZH-HMC-CW @115CD 0.371 ZR -MC -CW @15CD 12 0.069 0.828 ZR -MC -W @15CD 0.064 0.03 Amps 1,442 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.442 Amps For 5 Minutes= 0.121 Amp -hours 25% Derating= 1.051 Amp -hours Total System Current Load: 1.051 Amp -hours Eiattery Pairl to:be..Use d 12VDC Amp-hoWa 7 2 ►H Notification Appliance Circuit Detail PROJECT: EXCALIBUR CUTLERY Panel: PAD -3 BPS Date: j March 1, 2012 !Wire Resistance 2.58 CURRENT TOTAL=1422.00 !ZH-MC-CW @15cd ZH-MC-CW ©30cd 1 1ZH-MC-CW @75cd ZH-MC-CW @95cd 1ZH-MC-CW @115cd 1 ZR -MC -CW @15cd DEVICES 3 _87 131 222 292 371; 69 TOTAL mA=l jTotal Wire Resistance (R ) Total Device Load,Amps (i) Volta ge Drop ( E) I EOL Voltage 0 131 222 0 01 69 422( 14 189 23.591 422 (W L * 2) * (R/ft) (Total Cct Load) (E=1*R) 24-E) 0.98 0.42. 0.41; 23.59 SYSTEM CALCULATIONS TO NEAREST EXISTING �sl �C J, b E., EOL POWER SUPPLY Si S1-1 S1-2 S1-3 15cd 30cd 75cd TO NEAREST EXISTING DATA LOOP FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 03/08/12 z aaaaa C) >s- co cc z w co J~gm W o(nz d J° CJ - Cr CC �z5 < <m— rrUi t.l.!LL"T T CV or 0 0 w z LU z 0 z C/) z O ✓ J 0 U) 'GALE: NOT TO SCALE~ DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:02/29/12 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM JOB NUMBER: 55430 1 SHEET FA 03 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved G. R C =RID \-MALL COMMON AREA —\ LEASE LINE 11, s'-0° LEASE LINE L EXISTING ADJACENT TENANT S?ACE NO WORK THIS AREA ca in O' -O" EOL S1 RETAIL BACK R✓CM IEI HT -R TSM TO NEAREST EXISTING POWER SUPPLY 2 S1-1 y-�( 15cd 1%-1\ RES ROOM S1-2 30cd ALU 1 NUV STOREFRONT WITH GLAZING TO NEAREST EXISTING EXISTING/ OP 1-IOUSE -C NO WORK THIS AREA - D E) NEUTRAL BIER TO REMAIN OUTLINE OF EXISTING SULK -IEA D A>=OvE cst to LEASE LINE EXISTING ADJACENT TENANT SPACE NO WOK T1 -IIS AREA (E) ELECTRICAL PANELS TO REMAIN LEAS- _INE FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Prorietar and Confidential, Co • ri. ht 2012 b Guardian Securit S stems, Inc. All Ri • hts Reserved 1743 1 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 DESCRIPTION SHOP DRAWINGS W 1-- Q 0 03/08/12 0 CU *co Wz Liu 0 0 0, F. E O) E ci)Z CC I (/) 14) C w<4:cm� 0 tuilis W � �~ T N WLL `�CALE: 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 02/29/12 BACKROUND PLAN PROVIDED BY: .10B NUMBER: 55430 J SHEET '`/� FA -04 METAL STUD FRAMING AND GUL BULKHEAD AT 10'-e" AFP EXISTING ADJACENT TENANT SPACE NO WORK THIS AREA MALL COMMCN AREA t�1 r1 ALUMINUM STOREFRONT WITH GLAZING D • D N N l 1 OUTLINE CF EXISTING BULKHEAD ABOVE (E) FINS AT BULKHEAD. TO BE DEMOLISHED EXISTING ADJACENT TENANT SPACE NOWORK THIS AREA EXISTING BACK OF HOUSE - CORRIDOR NO WORK THIS AREA REFLECTED CEILING PLAN 1/4" = 1'-0" Design per NFPA 13, Ordinary Hazard All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 02 — Add Reliable Model G4 Standard Response Concealed White 165° Pendents 1/2 x 1/2 (Storefront) © 12 — Add Reliable Model G Standard Response Semi -recessed 165° Pendents 1/2 x 1/2 (sales and backrooms) 14 — Total TUKWILA FIRE DEPARTMENT MEr T Please call 206-575-4407 .arid give this Fire Permit No.:: -S v 1 and exact address for shut- down or res`oratibn approval. INRETSENE C AREASPWHERE REQUIRED TDP BEAN/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS 1N thout Comments t_7 As Noted in Red Per The Attached_ Luer These plans have been rev1.3wed by The Tukwila Fire' Prevention Bureau .fr;r cool of rn n;:e with current City. standards. Acce:;i nce is i:ubiect to errors and omissions Which do not aui;hc rine violations of adopted standards and ord r .c The responsibii;ty for the adequacy of desion ; :::`. totally with the designer. Additions, deletioris to these drawings after this date will void tit;_. • , :`eptartce and will require a resubmittal of revisu c e vii s r::;r subsecpent approval. Final acceptance is sub;ect to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 3---/r-1)- By: /<. 3 Site Plan CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Vacant Space 636 211 Southcenter Tukwila, WA PAID MICR 09 2012 TISK HILA FIRE DATE: 3 , 9 • 11. DRAWN: a p' SCALE: DPI