Loading...
HomeMy WebLinkAboutPP - 221 SOUTHCENTER MALL - GALLERY AT SOUTHCENTER - PERMITS AND PLANS221 SOUTHCENTER MALL ASSOCIATED PERMITS 17-F-175 13-F-136 11-F-085 17-S-189 13-S-133 13-S-130 11-S-089 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review **PLEASE PRINT** .,�^ �,n King Co. Assessor's Tax lN�o.:' /� Site Address: j7 \ o V l I l C€ ` Y m \` Suite Number. 10 LW Floor Tenant Name: ) )i h C_� 5Yrieti New Tenant? ❑ - Yes ❑ - No Property Owner's Name: Wes -a Mailing Address: Yviari mer\'r City State Zap CONTACT PERSON -if there are questions about the submittal. C.,11.Cd\--VC Name: 1011' 4k Day Telephone: - • - Company Name: an fe Wtsk-er-hoo ,' Mailing Address:?If)SAX 12\\re_ • Y\IV ,\\ C_re 1 v0P� City State Tip 4 1' E-mail Address: NICET III number: a/ top ' OSI I•� Fax Number: Contractor's City of Tukwila Business License number Total number of new/relocated devices or sprinlder heads: O % Valuation of Project (contractor's bid price): S '7O•`'LJ��yy�� Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construetion — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature:, Print Name: Plan Permit App.doc Date: /'2g'17 ICC} -99.0)01 YScn Day Telephone: z-iZS 1.700009 8/22114 TFDFPForm 8 4.61.W% JPZMEC CITY OF TLKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-5754407 Date application accepted: FIRE PRO 1'ECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION Z rl Zq 3 O/ 3 0 King Co. Assessor's Tax No.: `� ` Site Address: 22\ ( S U k f ia/ - f -0 31L'0 aFloor: Tenant Name: , V New Tenant? Yes ❑ - No Property Owner's Name- C Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: KARINA VELIZ Company Name: GUARDIAN SECURITY SYSTEMS, INC Mailing Address: 1743 – 1ST AVE S E-mail Address: kveliz@guardiansecurity. com Valuation of Project (contractor's bid price): S Day Telephone: 206-734-6276 x229 City SEATTLE, WA 98134 State Zip Fax Number: 206-341-9928 Scope of Work (please provide detailed information): l/L(�(�( Liv V L CUIA.-moi • PERMIT APPLICATION NOTES Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CER1'1tY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING�. R OR AUTHS ' • ED AGENT: Signature: Print Name: C V ( l V e ( Plan Perrnrt App.doc ILDate: ' l ` 1 Day Telephone: /-l1 L( • � —L Cl " U ? l 5/]4/]0 Inll FP Form 8 4 tit SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 2.'2._\ Tilekceyil-t ' !1 1a t Suite Number: (D ) Floor: Tenant Name: CeO ,� " Q—• Property Owner's Name: V', S WX44, Wa'1[%qprert+- C r6 )p New Tenant? ❑ - Yes ❑ - No Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: k CICX S)iii)1 )1 J" nsfl Day Telephone: Company Name:11A?� �l r•P_'t—PC' �'�c�Y1 Mailing Address: RD aCX \2._11 l f 1 b.)/N\ mDL. City , 1tate Zp E-mail Address: r`s /�. Fax Number: -}2�' g'� • g dg Total number of new/relocated devices or sprinkler heads: l� Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): feeloa•1 - (3) 14eaa..s �1 b7 Il-cackS and PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: f c/C JSi(a Rabin j cin Date: to ' q- !J Day Telephone: 4/24•1157-76651 Plan Permit App.doc 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Cache 221 Southcenter Mall Permit No.: 13-S-133 Date: June 17, 2013 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • Maintain a 4 ft. clear space around the sprinkler riser for emergency access. • An electrically supervised post indicating valve (PIV) is required. • PIV shall have the building number served by the PIV stenciled vertically in 3 - inch high white numbers on a "safety red" background, facing the direction of vehicular access. • The height of the fire department connection (FDC) shall be 36 to 48 inches above grade. • The FDC shall have a downward angle bend of 30 degrees with a 5 -inch Storz connection and a Knox locking Storz cap. • Install listed water shields on in -rack sprinklers. • Installation of all electrical pre -action system components requires a separate fire alarm permit and an electrical permit. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Tuscan Sanctuary & Spa 221 Southcenter Mall Permit No.: 11-S-089 Date: April 26, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3..6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. 1 . v • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Permit No.: Date: Reviewer: Lush Cosmetics 221 Southcenter Mall 17-S-189 October 9, 2017 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. NMubcr of Pages (including, Cover) 06/04/2013 13:49 4254016695 FAX TRANSMITTAL CROWN FIRE PAGE 01/01 Fax No. CROWN FIRE PROTECTION, INC. tom: Company MEM 6.4.13 Fire Prevention Bureau Tukwila Fire Department / Al Demo Permit 1 206.575.4439 [7 Urgent El For Review 0 Please Comment 0 Please Reply Cristae Ogland PH:425.481.7669 FX:425.481.8695 Comments Please provide a demo perrnit to remove (5) fire sprinkler heads and the piping under the existing me7..7anine that is being removed at the Cache project located at 221 Southcenter Mall. The building permit number is D13-122. Please let me know if you have any questions or need any additional information. Thanks TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address for shut- down hutdown or restoration approval. kir P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8_695 TYPE '01' GYP.BD. 10'-0" A.F.F CEILJNG TO BE PAINTED . k r _ TYPE '01' GYP.BD. 9'-0" A.F.F CEILING TO BE PAINTED_ EGGSHELL WHITE - RE; MATERIAL SCHEDULE A-105. PT -1 CORRIDOR HEADER TO BE AT 7'-4'A.F.F. Design per NFPA 13 — Ordinary Hazard Group 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions o i5 — Relocate Reliable Model G-56 165° Standard Response Pendents 1/2 x 1/2 o — Add Reliable Model G-56 165° Standard Response Pendents % x % • E — Existing no change /l//l///Wile ll//ll/l/Il/8//011/IIMMll mg/ Amor. 77riirrrrrriiriiairfi/MY 5iillrrirAZ. 15 ntimiriirrriiiriiirii rririni,7 Mar• ill t7 rrrrrtrrririr: ////1/////11/1//1/////// /1717��/�1�10�//1o/fOII/////1//1//1//1/////////1/%/ fi �% PE 'Al GYP.BD. -e- 'IF 1'-0" A.F.F. CEILIN TO BE PAINTED EGGS ELL BLACK ;nos TYPE 'Al' GYP.BD. 10'-0" A.F.F. Without C c mfnients As Noted in Red Per The Attached Letter These -plans -have been reviewed bV The Tukwila Fire Prevention Bure:avr for confarmancf, with current City standards. Accet .Jlice is :;uhjec,' ' errors and omissions vqhich co not authorl:.r v.ci72tion:3 of adopted standards ant ThF for the adequacy of cies, totalM h die designer. to cheEe drawings after Additions,C,c..aUr,;;.,, ..,. :�.�niiUi.. this date rvrii! 'r : "CepCaPCe and wiii require a resubmltual r= ui.r,ac ;or, tib equent approval. Final accen{ r,ce is su ieci tofu dela test and inspection by TThe l iFire are•! n oa Bureau. l le Tltl��e5. Ali~ .c .. �.iV� t E Date: 10-0- Fle ead rink! roil ................ �`�` Corrugated stainless steel hose with stairiless steel bras :;�; ,. avh Able in 2', 3',4',5' & 6' Iegnths . . yes s;• Multi -Port Bracket • Adjustable Flub i" FLEXHIAO I INDUSIRIESLJ Flexhesd'- omn-iercial Ceilirig Unit T -Bar Ceiling Installation ' Model 2024,2036,2048,060,2072 /41 /40 /f/ 0 // %%¢ o,/0 /j / A, A 111/rf0 of !/ r /II Fr 40 Fij9 Y/f, %/ ror Aq1 HOP /4: Prre 1/1 TRACK LIGHTING TO BE SU 'MOUNTED INSIDE RECESSED POCKET PROJECT LOCATION WKWILA FIRE 1;EPARTMTT fit' Piease caN 206-575-4407 and give this Fire Permit No. S- and e;,:asct kick;: s 3^J for shut- down or restoration approval. :a613a9i[�lilss�i TYPE 'Al' GYP.B CEILING TO BE PAINTED EGGSHELL BLACK TYPE 'Al' GYP.BD. 10'-0" A.F.F.': PT -2... CEILING TO BE PAINTED EGGSHELL . BLACK - RE: _• -. MATERIAL . SCHEDULE A-105 TYPE 'Al' GYP.BD. . 10'-0" A,F.F. 0 CEILING TO BE f.? PAINTED EGGSHELL PT -2. Welatigasteem LUS' FRESH ANDMADE C LEVEL 1- SUITE 221 John ;Abel 9760-0591.0G: -1.6.w1.3 ..> -!mown Fire Prate a; Ire • a a rfi P17 g.. ill/ N. REFLECTED CEILING PLAN I SCALE: 1/4* =1'-0" CROWN: FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Lush Cosmetics Space # Tukwila, WA DATE: c4.2 s,1-1 DRAWN: SCALE: I PAID SpP2j201i T UK HILA FIR . ?9 d o� H Y EC DDI N M I S EET \UN3E SHEET TITLE FA -01 SYST -N v ATIO FA -02 TYPICAL WRING A\3 VOU\ TI \G DETAILS FA --03 SYSTEM CALCULAT 10\S A\ SI\GLE LINE DIAGAv FA -0 FIS ALAV SYSTEv PLA\ SHEET INDEX i( Without Comments As Noted in Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and oInisslons which do not authorize violations of adopted 7':3ndards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletionh -._, revisions to these drawings after thte, dot- i rn "nid rt,is Pcceotance and will require a for suosuauerit approval Final acceptance I:- .5uoJect to field test and Inspection by The Tukwila circ Prevention Bureau, Date: ' -11.4 1 ajr� WIRE SCH TUKII.Vi ,., PRE p: EPARTME't3TT ?,-."),:1-3"/5-41407 and r'!4 e. yi rill r-iyr9 1t NO. S- aldress for shut- down or restoration approval. 3., LE AN CO\QUIT FILL C AT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIE`DED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSCCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY; ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY E 1 1 2 2 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S BOX CEILING TENANT J -BOX DE (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR • A.F.F. ABOVE FINISHED FLOOR N/A N /A N/A N/A E EXISTING DEVICE N /A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N /A N/A N/A NOT APPLICABLE N /A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A N/A 1J/ A GREEN AS BUILT REMOVE N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LE LL LUSH FRESH HANDMADE COSMETICS SUITE 221 ii IJ - -/ 1 macy r.' Y-1 FETA, SEARS E s, PAID � SEP 13 2017 ,% TUKWILA FIRE SITE PLAN c�-- Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ir7 cls (f) LU r - >- w N 0 a_ LL G SHOP DRAWINGS 0 w 0 0 L.LI 0 0 z 1 w cr Li... 1 0 0', 0 CV CV co LU co no-) J Q < 0 z -±- w (!) Q w O� 0 0 co cv (SCALE: NOT IT SC. Lc DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:009/011 17 BACKROUND PLAN PROVIUr a JY 'OB NUMBER: _036, - 1 SHEET FA- o THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ - DEDICATED EMERGENCY • FROM EXISTING MAIN FACP C CABLE C' CABLE (-) (+) (-) (+) LiL�i INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 3.6k EOL HARD LID CEILING HARD LID —\ SPEAKER SUPPORT TILE BRIDGE NAC S4 NAC S3 NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) 0 (+) (–) STROBE SPEAKER FROM PREVIOUS ADDRESSABLE DEVICE HFP-11 TBI 000®TTO 0®10 NO COM NC rpt 00 TO FAN SHUTDOWN EOLR 470 m SWITCH + — INPUT LED TSM -1 0 TO NEXT ADDRESSABLE DEVICE NO ® COM B HTRI-R NC ® 0 O TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) O STROBE (+) O STROBE SPEAKER (+) (–) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved : rr) ON 00ONN..1 O t - (r) LLI I-- �� LU 1ST AVE. SO., (1) 0 LL1 LLI () a LU J LLI Ch m 0 > 0 LU cY DESCRIPTION SHOP DRAWINGS LU 1- 0 0 0 (S-CALE: NOT TC SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 009/01/17 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 2636i - 1� SHEET FA -02 A B C D E F G H 1 J K FIRE ALARM BOOSTER Project: LUSH FRESH HANDMADE Panel: EXISTING BPS PAD -3 Date: September 5, 2017 Module/Device Fa P ADD SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 Current Load: 15 0 Standby: Alarm: TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 3649 Total(A)= 15 Total(B)= 3789 CALCULATION Device Type Qty Amps Total Amps Total Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). HFP-11 0.0022 0.0022 0.0023 0.000 FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps A B C D E F G H 1 J K FIRE ALARM BOOSTER Project: LUSH FRESH HANDMADE Panel: EXISTING BPS PAD -3 Date: September 5, 2017 Module/Device POWER COSMETICS REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 3649 Total(A)= 15 Total(B)= 3789 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 3789 Total current ratings converted to amperes (line D x .001) 0.015 3.789 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.3156237 Add lines G and I Total Standby and Alarm AH 0.6756237 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.81074844 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 CALCULATIONS Notification Appliance Circuit Detail PROJECT: LUSH FRESH HANDMADE COSMETICS Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLY__ Date: September 5, 2017 Wire Resistance 2.58 CURRENT TOTAL= 3649.00 SET -MC -CW @15cd 1 SET -MC -CW @30cd 2 SET -MC -CW @75cd SET -MC -CW @95cd 2 ZR -MC -CW @15cd DEVICES 5 69 0 111 111 200 400 264 0 69 138 TOTAL mA= 649 14 378 22.73 649 Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage (WL*2)*(R/ft) (Total Cct Loa d)- (E=1*R) 24 E) 1.95 0.65 1.27 22.73 1500 DEVICES 1500 S EOL S3 S3-1 S3-2 30cd 75cd D EXISTING TENANT J -BOX S3-3 S3-4 75cd 15cd D,I -0 IHT-RI 21 • TSMI SINGLE LINE DIAGRAM S3-5 15cd FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. r) o co Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved L1J RELEASE/REVISIONS REV. BY: 0 m 0 i DESCRIPTION SHOP DRAWINGS DATE N 0 0) O 0 w co O z w CO CO 0 01-6 LU ao)z C� o J o >, w z 0 w� Zw < CC Q 1— Iwco �� W ©1— CC o co LL `\' 1 J D 0 0 LLQ rSCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 009/01 / 17 BACKROUND PLAN PROVIDED BY: _JOB NUMBER: 26367-1.2 r- SHEET FA -03 TO TENANT J -BOX TO TENANT J -BOX D S,V Sr,03 PRP F1/0)SilaVES : FFP FIXED Sh121.VES •12.‘24. A2x24. -••• • ; PPP MID SELVES ir 24. S3-5 15cd S3-1 WATER COOLER xi 5 • • 30cd LOCKE imuzEff4DED:TisfiFRflTERO.r 4.9%.24' '3JVS j KNOT WRAP CANVAS Lu BAGS 0 PERFUME GIFTS — GIFTS - - GIFTS ADJ. TENANT 0 SCALE 1 , STORAGE L -- C.HT: 10'-C CEILING - F FINISH CASH S S3-2 75cd mum ..• 111 SOAP CANVAS BAGS IMPULSE CAT: 1 '-8° CEILING P2 FINISH CONSULT I Da0 • ! 1 :6‘; . ; CART ; ; • • ,•1...!; ; • •• V CANVAS BAGS _ CAR* \-1—••••, I! • •••• K K -•(,0` • 5:11' :1 16 DEMO SINKS , ------- WINDOW DISPLAY I ! !- ! ! f -FEATURE S3-3 75cd 1 ! C,E,101 c1- • , .; • I_ -1 ! ' • I • C.HT: 10.-0" CEILING FINISH FLEXIBLE FLEXIBLE CONSULT FRESH PAN FLOATING SHELVES 1 SHOWER r- ; MOUTH L. k SKINCARE 1 i • • FRESH (3 FRIDGE / MASSAGE .• , • ' - • / / FIRE ALARM SYSTEM PLAN ADJ. TENANT FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 11 11.*. !!!!•••• 4.1? s ‘f.;;-• J04'04 cQ 0-• r) j 1_1_1 RELEASE/REVISIONS !REV. BY: DMG 1 DESCRIPTION SHOP DRAWINGS DATE r`•-• •••••...., .-- 0 •-•.., 0) 0 (-) - - <<" ..- -....... ..,-- iiJ SCALE: 1 / 4" = 'C'' DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 009/01 7 BACKROUND PLAN PROVIDED BY :..JOB NUMBER: 26367-1,i 1 SHEET FA -04 DDITION N rA. Sea tie/ t hoot Comments 51( As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prev n Bureau au for conformance with current City standards. Acceptu":r,, is subject to errors and omissor-,s which rr rj _ •ithorize violations of adopted stantards and dr6En.nnce , T,,e r s uns1O!Iity for the adeq lacy o1 des! :n f' .: : totally wirfo e designer. Add:{+ofS, d4i¢'rc:i ;a:,; to these drawings after this ('C VJl►I \'C d .'f. :r":::%lc'.1Cc :ijl!! vv!it require a resubmittal of revises: cirawiNtd: .,..'resent approval. SHEET \Uv3ESHEET TITLE FA -01 SYSTE v I\FOS 1ATION FA -02 TYPICAL WHI\G A\3 V OU\TING DETAILS -A-03 SYSTEv CALCULATIO\S A\D SINGLE LINE DIAGRAM FA -04 FIDE ALA v SYSTEM PLA\ SHEET INDEX WISE SCHEDULE A\D CO \ D U IT FILL C HATT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARA RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX EX EX EX 5 4 SYMBOL DESCRIPTION MODEL The Tukwila Fire Prevention bureau. Date: (0-I k - (3 By: k:W► si 1 T .. nb • NOTICE 4 completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. n - F- wt'i 3 S -.arld_exact t9�i; f,,_+.�.`-s-for-shut- down or reaor at on app.i oval. MOUNTING HEIGHT BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS EX (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP w/ 1G RING CEILING ®EX DUCT DETECTOR D AD2-P W/ SIEMENS DUCT HOUSING HFP-1 1 DET. VERIFY IN FIELD TSM DUCT DETECTOR EX TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HTR -R EX INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY 11'1 FIELD FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX W/ 1-1 /2 EXTN CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N /A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 171,2755: 'a'al`.Ea�p.S 6.1 ,«.nW%S3 YALE maty 4 LEVELS 2 C,4C7 f GU B.JaTO T -T 1., 4' D TO CO _._._. s•a=. CACHE (221) / SPACE #640 -1- A= 'S E.Sc X11 L IJ I ... JCPenney PAID JUN 112013 TUKWILA FIRE rr W e cc D 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS 1 DATE M C. 0 0 0 aaaa< 0 (0 ZWco D v,- < Q PnZ < 1O CC cc w 5 05 W rr LT_ 1- T N 0 0 W N >El N /SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE:06/07/13 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN CC 00 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved .JOB NUMBER: 5221-1} �► SHEET .\ V FA -01} \,. 12OVACC-60NZ DEDICATED EMERGENCY THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NEPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE: FON ADIX00NA1. SPECSICATIONS SEE PRODUCT DOCUMENTA1Nk1. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC HEWIsglifiD TD NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE - rRDN XLS CONTROL PANEL (+ DR PREVIOUS ADDRESSABLE DEVICE - O 0 0 0 HTRI-R Igri e: 1 O 0 NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C—CABLE C—CABLE El PAD -3 no INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - O 0 3.6k EOL • (-) (+) SPARE SPARE SPARE F'D ❑ FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (—) I 0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. • 0 m C) m 0 P1 m O (+) WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FRJFPLR RED (JACKET) 'CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 F r n GROUND L- N 0 HTRI-R 0 (+)) TO NEXT DEVICE OR (-) 11 POWER SUPPLY & RELAY MODULE WIRING DETAIL FROM PRECEDING SPEAKER < OR FIRE ALARM CONTROL PANEL < (+) (+) 11 C 11 (-) > STCP IF LAST DEVICE ____> DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL SPEAKER 0 0 1:1:1:1:111:1:1 0 STROBE Q IDE -i CIRCUIT QO❑ (-) STROBE CIRCUIT STROBE Q 0❑ 0 0 a 8 11 - �NCN[I ON " I:11:1:11 1:1:1 out (-) V (-) SPEAKER CIRCUIT (+) (+) D=ri LI �El STROBE IDE ll ' CIRCUIT SPEAKERISTROBE ❑o — O 0 M 0 O , i DESCRIPTION DATE M ' 1 ' r ? a" 0 +- ASCOIFON f (0 Yl//' 316 I 1:1:1:1 1_1:4:1* 0 -moi i- Ni {may; 53 z aaa<a -- 10)' (-) ❑I1 (-) STROBE SPEAKER CIRCUIT SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS (+) (-) SPEAKER CIRCUIT 5 TO NEXT APPLIANCE 5 OR 24K (EOLR) S TO NEXT SPEAKER OR END OR LINE RESISTOR 24K (EOLR) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —1 — FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL HARD LID CEILING '�. SPEAKER SUPPORT -ILE-- BRIDGE HARD LID > TO NEXT ADDRESSABLE DEVICE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE • • • SPEAKER STROBE MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX \ JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 0 0 TO NEXT DEVICE -- CADDY BAR SMOKE/HEAT DETECTOR — .IEJI SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright: 2013 by Guardian Security Systems, Inc. All Rights Reserved ca 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE M 1` 0 (0 0 z aaa<a c0 co Z w co O r1T 0� Q PZ QJE- w �z o cc I w�Q' U < ~ w� = T N N 'CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 06/07/13 BACKROUND PLAN PROVIDED BY: `JOB NUMBER: 5221-1) SHEET +�� FA -02 J Notification Appliance Circuit Detail PROJECT: CACHE Panel: EXISTING PAD -3 POWER SUPPLY Date: June 7,2013 .U..iiii'',,,;J:.,,ki •i3,!.,11(‘',1*i ' thquii- -. !':' ; , : 2 SET -MC -C ©15CD 87.5 2 SET -MC -C ©30CD 131 0 :SET -MC -C ©75CD 222 1 SET -MC -C ©95CD 292 0 iZR-MC ©110CD 259 4 ZR -MC ©15CD 69 0;ZR-MC ©30CD 98 . , 0 ZR -MC ©75CD 175 TOTAL mA= DEVICES=: ;Total Wire Resistance ( R) Total Device Load, Amps (1) ,Voltage Drop ( E) EOL Voltage PROJECT: CACHE Panel: XLS-V Date: (June 7, 2013 ir 19 !70.7V1/8 27 70.7V1/4 0 i70.7V1/2 0 70.7V 1 DEVICES= 46 !Wire Resistance 2.58 CURRENT TOTAL= I 1005..00 175 262 0 _ • 292. 0 276 01 .„.. 0 10051 14 187 23.03 1005 (1/1/L 2 )* (R/ft) (Total Cct Load) (E= I * R) 24 - E) 0.96 4$1.01 0.97. 12.3.03 Notification Appliance Circuit Detail r • •LWire Resistance 2.58 CURRENT TOTAL=r#REF! 1.8 34.2! 3.54 95.58 0 0 TOTALrnA=i 129.78! 14 Total Wire Resistance ( R) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 1,243 19.56760665 1•'• 129i78 WL *_2 ) * (Rift) 6$1 (Total Cct Load) 043 1(E= 1* R) 0183 (24 - E) 2317 cu Iu fi) 743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 (7) LU LLJ Cf) uJ _J 1.1_1 SYSTEM CALCULATIONS 120VAC, DEDICATED (BY OTHERS) S,V,V S,V,V S1-1 15cd V-1 1/4-W S1-2 S1-3 30cd 15cd V-2 1/4-W S1-4 15cd 8 EX (HALLWAY) V,V S,V,V S,V,V S,V,V S1-5 15cd V-3 1/4-W S1-6 30cd V-4 1/4-W 81-7 15cd S,V,V S1-8 15cd S1-9 95cd V-5 1/4-W EOL S1 REV. BY: EXISTING SIEMENS PAD -3 Signal Extender Panel Ba e oad Calculations z 0 a. (..) (1) Lu c) SHOP DRAWINGS CurrentLoad: Standby: Alarm: to '--- 1, 0 (0 0 2 <<<<< Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -C ©15CD 2 0.0875 SET -MC -C ©30CD 2 0.131 SET -MC -C @75CD 0.222 SET -MC -C ©95CD 1 0.292 0.292 SET -MC -C ©110CD 0.259 ZR -MC ©15CD 4 0.069 0.276 ZR -MC ©30CD 0.098 ZR -MC @75CD 0.2 0.03 Amps 0.598 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.598 Amps For 5 Minutes 0.050 Amp -hours 25% Derating = 0.963 Amp -hours Total System Current Load: 0.963 Amp -hours Battery Pair to be Used: r 12VDC Amp -hours 7.2AH Notification Appliance Circuit Detail PROJECT: CACHE Panel: EXISTING PAD -3 POWER SUPPLY Date: June 7,2013 .U..iiii'',,,;J:.,,ki •i3,!.,11(‘',1*i ' thquii- -. !':' ; , : 2 SET -MC -C ©15CD 87.5 2 SET -MC -C ©30CD 131 0 :SET -MC -C ©75CD 222 1 SET -MC -C ©95CD 292 0 iZR-MC ©110CD 259 4 ZR -MC ©15CD 69 0;ZR-MC ©30CD 98 . , 0 ZR -MC ©75CD 175 TOTAL mA= DEVICES=: ;Total Wire Resistance ( R) Total Device Load, Amps (1) ,Voltage Drop ( E) EOL Voltage PROJECT: CACHE Panel: XLS-V Date: (June 7, 2013 ir 19 !70.7V1/8 27 70.7V1/4 0 i70.7V1/2 0 70.7V 1 DEVICES= 46 !Wire Resistance 2.58 CURRENT TOTAL= I 1005..00 175 262 0 _ • 292. 0 276 01 .„.. 0 10051 14 187 23.03 1005 (1/1/L 2 )* (R/ft) (Total Cct Load) (E= I * R) 24 - E) 0.96 4$1.01 0.97. 12.3.03 Notification Appliance Circuit Detail r • •LWire Resistance 2.58 CURRENT TOTAL=r#REF! 1.8 34.2! 3.54 95.58 0 0 TOTALrnA=i 129.78! 14 Total Wire Resistance ( R) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 1,243 19.56760665 1•'• 129i78 WL *_2 ) * (Rift) 6$1 (Total Cct Load) 043 1(E= 1* R) 0183 (24 - E) 2317 cu Iu fi) 743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 (7) LU LLJ Cf) uJ _J 1.1_1 SYSTEM CALCULATIONS 120VAC, DEDICATED (BY OTHERS) S,V,V S,V,V S1-1 15cd V-1 1/4-W S1-2 S1-3 30cd 15cd V-2 1/4-W S1-4 15cd 8 EX (HALLWAY) V,V S,V,V S,V,V S,V,V S1-5 15cd V-3 1/4-W S1-6 30cd V-4 1/4-W 81-7 15cd S,V,V S1-8 15cd S1-9 95cd V-5 1/4-W EOL S1 REV. BY: 0 m 0 z 0 a. (..) (1) Lu c) SHOP DRAWINGS DATE to '--- 1, 0 (0 0 2 <<<<< 0 co Z w g. 0 IJO < z 00 LU <2 =Pa Lu z cc ci 0 2 cc w 5 0 5 < al _IF - cc V) cr 0 0 w z J z (7) 0 zz0 0 (.1 0 (1) ›- fcCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 06/07/13 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM JOB NUMBER: 5221-1} r- SHEET FA -03 Proprietary and Confidential, Copyright( 2013 by Guardian Security Systems, Inc. All Rights Reserved EX (HALLWAY) J_. (J V,V' S,V,V TR Y S1-9 95cd V-5 EOL S1 SAES OR I �I f,,uyrrr.T :N0 S,VLV' —0 I-. ;81-7 15cd F I - L., ; s,v,v, b S1-6 30cd V-4 H1 7 I PR TING P 00V H1 AREA S1-4 15cd a� v,rr FITTIN 6 ROOM n svV'—a TOILE T DOR 8 S1-5 8d V-3 30 S S1-2 3Ocd V-2 FIRE ALARM SYSTEM PLAN 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS (REV. BY: 0 DESCRIPTION SHOP DRAWINGS DATE 06/07/13 2CCC<C 2 O co ;t co Zw0 Q 0 (7) Elm CD FY) Z (/) < --1 >m O Luiz (I) w< cc w w� nc �� N 1.1.1 SCALE: DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 06/07/13 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 5221-1} I. SHEET FA -04 Proprietary and Confidential, Copyright:: 2013 by Guardian Security Systems, Inc. All Rights Reserved \ �/ ADJACENT TENANT (fr`\ eisP RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP DEAN/ C-CLANP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JO/ST/TRUSS HANGER DETAIL NTS EXISITNG GYP. BD. CEILING TO REMAIN PAINT PT2 • NEW 24"x48" ACOUSTIC TILE LAY—IN CLG AT +11'-6" AFF. (STOCK ROOM LOCATION ONLY) (ACT1) AIWt b 4.0 .4 L;:i El Without Comments As Nott.,.. -,d in Red O Per The Attached Letter These plans have been reviewed by TheTukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to e.rrors and omissions which do not authorize v!otiOns of adopted standards and ordinances. The resp:v•isibilicy for the adequacy of de,sif s tot:,:ily with the designer. Additions, delet o elor6w Liles;:=:: cirMilgs after .thIs date. will k.fc:dric pc rJ1.,,,,Ifi(Q0€ a resubmIttal of f-.vis.eci fo; 5DqflL approval. Final acceptance is subject to field test and Inspection by Tne Tukwila Prevention Bureau. 3 1 ( Date:(0-( ADJACENT TENANT REFLECTED. CEILING / LIGHTING PLAN 1/4" = GYP. BD SOFFIT BOT.. PAINT PT2, GYP. BD HEADER BOT. PAINT Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 10 — Add Reliable Model G5-56 Concealed 155° Pendents Y2 x1/2 o 3 — Relocate Reliable Model G5-56 Concealed 155° Pendents V2 x 1/2 o E — Existing no change . CROWN FIRE -PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 : PH. (425) 481-7869 TUKWILA FIRE DEPARTMENT Piease call 206-575-4407 and give this Fire Permit•No. and exact address for shut- - ir tit down or restoration approval. Li Cache 1 221 Southcenter Mall Space 640 Tukwila, WA 98188 A 'on Sprit*.‘t1 'OtIghDge..004. ID ).3 5 2013 A AFIRE. ..1E.27ee,32 •PA JUN 0 • TUKWIL DATE: 6L(,,3 DRAWN: I ri SCALE: ' o f- I 1. 1111111171112111111111111 Imilill 1 1 AMAng-'. ' 1 11 - 0 immiffilliMm.= 1 TR 5 JI�I;.�) , g! ISI NI r.. ;�&]t v+5at. ' �; ::4, , ,24. yes rt,,'i; '. `l,'!. e r �rr,� �: � �'�:�7'•yx r v: --•-it thk immi iz�%i+t�dr��..�r:w`?�'.a_..C{rt,Y.ir.�S!21'_'•�y+.�i�.tc-rt'���t���-uJ...��_��.��i'�t�iy�z.'4. IP • • • mom •mo .ice __..Immo w ammo Ammo •s. ,t ••• c C.O.S.(E) REFLECTED CEILING PLAN SCALE: 1/41=1'-0■ E F G J RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS �—TOP WITH BSETSCREW 3/8' ALL THREAD RED HANGER DETAIL NTS • Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Dre"ention Bureau for cc f:Nrn==nce with current City standards. Acce :tan(L is;:i.b ect to errors and rnissionS which do not authorize violations of adopted tandards and ordinances. responsibility for the adequacy of design !'-'27.1'5 totally'with the designer. Additions; del tion:: r:r revisions to these drawings after this date w ll•void tt'i'•s 7,:ccept nce and w it require a resubmlttai of revised dra ,angs for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: `-1 -a,c, - t1 'By• Design per NFPA 13, Ordinary Hazard All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart ® 3 — Add Reliable Model F1 Standard Response 155 ° Pendents 1/2 x 1/2 o R11 — Relocate Reliable Model Fl Standard Response 155 ° Pendents 1/2 x 1/2 o 3 — Plug Reliable Model F 1 Standard Response 155 ° Pendents 1/2 x 1/2 • E — Existing 17 — Total RCP -0I 4' 0' 2' SCALE 1/4' = 1'-0' K VICINITY MAP 4 r!! LA FIRE DEPARTMENT Please ciA 2?<;,_•5755447 and F give this re Permit No. /1 -S- and exact address for shut- down or restoration approval. SITE PLAN 4111111 CROWN FIRE PROTECTION INCORPORATED. P.U. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Tuscan Sanctuary Salon & Spa Southcenter Mall 2-,;-1 Tukwila, WA AP TUKV DATE: L; 15 DRAWN: Ci SCALE: l: u RAID 18 2011 /ILA FIRE SHEET NUM3ER SHEET TITLE Er�A mscA F RE ALARM SYSTE K .`. ILA, WASH FA- 01 SYSTEIv INFORMATION FA -02 TYPICAL WIRING AND MOUNTI\G DETAILS FA -03 SYSTEM CALCULATIONS A\ D SI \GLE LINE DIAG RAI/ FA -04 FIRE ALARIv SYSTEM PLA\ SHEET INDEX 0 ‘,nl;thout Comments f;r Noted in Red Pe; The Attached Letter -e plans ray:: he_f • reviewed by The Tukwila Fire otion Burez ,..-iformance with current City ,rds. Accept?. cc ; - c-,.;biect to errors and ns which do : ,r o. ize violations of adopted is and ordinal,c The responsibility for the ;zoequaoy of design rests oraliy with the designer. Additions, deletions or rf',13i0M. to these drawings after t`,is date will void th`' T,- e7tance and will require a iittal of revises for subsequent approval. acceptance is subic' i to field test and inspection by Pire Psevt ° ^n Bureau. [._�--`''' �j,��� NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. F--aum of test will result 1 -,rillstrledfmn Fee and TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give the Fire Permit No. j - and exact address for shut- down or restoration approval. D U LE AND CONDUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END N SALON DDITION TON FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 1 1 1 2 5 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD -3 -ENOL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HTR -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2 EXTN FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F. B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND macyA 4 = VELS NORDSTROM 3 LEVELS EYPESSJ 171,275sf JAYES BT ISNE TOKYO TDKep ,AEETI GO-, LI 9r SS 117,, TN.E aPorls I �D MPB AN 3AlleCi ClOGE CASJA_ KING CD'.>UTY LBEARY jRED YEYEN (£RECEnS SLATE 4 CSD S I I CGGGIA GATE G GAUK a'L"FSAS b_. CN eot Root ARI.UET`E .h :SBUIE I EST Y rttn I ° �x `=r1 sm.," JAMA -INCE e S.AT1 STAPEJ K,FIZ_TN5.n1.ESS SAT_ ,_BS TAY S+-. YID IN 'WASILNCTCN £9f$Cw-N=t PALNIC S. AVEDA TUSCAN SALON (221) 9xEK SEES 9xC'( 5.4-x3 nem aASSN O LEG WENS 1.iCEtNi f EXSTING JCPenney 3 LC'GLG 276,458sf SEATS PAID APR 19 2011 TUKWILA fIRE 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 04/15/11 2<<aaa z O Z co < 03 (f) OZ z <W° `' W Z Z C/) cn Q I- cc �. Q Q cn-g O_ owN j LL I - <C 'GALE: NOT Z 0 0 Z W (i) TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:04/15/1 1 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1,OB NUMBER: 552235.3 j SHEET FA -01 120VAC-60HZ DEDICATED EMERGENCY l THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' AIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NO1E FCR AMID:NAL SPECSICA1K1 S SIE PRODUCT DOC MNTA110N. *CONTACT RAT@NGS 4.0A 0 125VAC 4.0A 0 30VDC REM TD NEXT ADDRESSABLE r+ DEVICE STOP IF LAST DEVICE - FR011 XLS cZNTRIL PANEL (f DR PREVIOUS ADDRESSABLE DEVICE O O 0 0 mND` t J -� ' I et 1 HTRI—R I k4 e; 1 O NOTE: FOR ADDITIONAL SPEORCATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 PAD -3 00 INPUT INPUT TROUBLE WA.C1 NAC2 NAC3 NAC4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - 0 (-) (+) 'SPARE SPARE SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) 0 0 ASCVEFtt 11:I:I:111:1:1• POWER SUPPLY & RELAY MODULE WIRING DETAIL FROM PRECEDING SPEAKER < OR FIRE ALARM CONTROL PANEL < (+) (+) (-) N NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. a v S m z 5 m o m O m No 0 g m F� m (-o)(-) v (+)(+) v (+) TSM -1 0 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SE TYPE COLOR CODE TWISTED PAIR WITH SHIELD f18 FPI IFP.R RED (JACKET) *CONTACT RAT111CS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. F GROUND L O O 0 0 rT , e HTRI—R I o0 /- .)) i (+)>TO NEXT DEVICE OR (-) STOP IF LAST DEVICE DRY CONTACTS TO VAV -_ FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL SPEAKER 0 LI STROBE 0 CIRCUIT QED❑ 0 0 I:1:1:1:111:1:1 I (-) STROBE CIRCUIT STROBE I1❑ ❑I1 1 %ED quo � , SHOP DRAWINGS 0 0 t - l ,_ \ WEEK u: 7 1- LO t I 1- o \ \._ .....' . 11'1:1:I I 1:1:1' 0 k I" (-) L- SPEAKER CIRCUIT (+) V (+) SPEAKERISTROBE 1 0 0 STROBE CIRCUIT (-) SPEAKER CIRCUIT SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS (-) SPEAKER CIRCUIT S TO NEXT APPLIANCE S OR 24K (EOLR) S TO NEXT SPEAKER OR END OR LINE RESISTOR S 24K (EOLR) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +32' FF (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR — FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR MR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL HARD LID -\ CEILING > TO NEXT ADDRESSABLE DEVICE HARD LID —\ SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2' EXTENSION CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX TeintrairOl JUNCTION BOX MOUNTED AGAINS CEILING SUPPORT TO NEXT DEVICE —CADDY BAR ,E31 SMOKE/HEAT DETECTOR 1 SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by PAID APR 19 2011 TUKWILA FIRE ‘i/7I-2o3 Guardian Security Systems, Inc. All Rights Reserved s z FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 0 M 0 DESCRIPTION SHOP DRAWINGS LJ \ 1- LO o \ 0 o«a<< z J 0 riLQSS co c z z < w 1Q w z z UCC te_ ¢owff Z O 0 z c� z J U 6ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/ 15/ 1 1 BACKROUND PLAN PROVIDED BY: _JOB NUMBER: 55223_1 1 SHEET FA -02 HTR -R, Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.002 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps ENS. RAD gn axle uletions Current ,o id:: rib irrl Device Type Qty Amps Tota 1 Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -C @15CD 2 0.0875 SET -MC -C @30CD 1 0.131 SET -MC -C @75CD 2 0.222 SET -MC -C @95CD 0.292 SET -MC -C @110CD 0.259 ZR -MC @15CD 2 0.064 0.128 ZR -MC @30CD 0.098 ZR -MC @75CD 0.2 0.03 Amps 0.158 Amps Standby Current Load: 0.03 Amps For 24 Hour 0.720 Amp -hours Alarm Current Load: 0.158 Amps For 5 Minutes 0.013 Amp -hours 25% Derating= 0.917 Amp -hours Total System Current Load: 0.917 Amp -hours Pa td be' Used. 12VDC Amp -h© 2AH EX (HALLWAY) TO NEAREST EXISTING , IHTR-RI DATA LOOP t D -o PROJECT: Notification Appliance Circuit Detail AVEDA TUSCAN SALON Panel: PAD -3 POWER SUPPLY Date:1 April 18, 2011 Wire Resistance 2.58 CURRENT TOTAL= 878.00 SET -MC -C @15CD 1 SET -MC -C @30CD 2 SET -MC -C @75CD 0 SET -MC -C @95CD 0 ZR -MC @110CD 2 ZR -MC @15CD 0 'ZR -MC @30CD 0 ZR -MC @75CD DEVICES= 7 2221 292 259 64 98 175 TOTAL mA= 'Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop ( E) EOL Voltage 1751 131 4441 0 01 .._ 128 01 0 8781 14 162 23.27 ( WL * 2 )* (Rift) (Total Cct Load) 1(E=I*R) 24-E) 878 0.84 0.88 0.73 23.27 Notification Appliance Circuit Detail PROJECT:: AVEDA TUSCAN SALON Panel: XLSV Date: j April 18, 2011 Wire Resistance 2.58 CURRENT TOTAL=1#REF! 21 170.7V 1/8 31 70.71/114 0 170.7V1/2 0 70.7V1 DEVICES=! 52 SYSTEM CALCULATIONS 2C,V,V 1.81 3.54 0! 0 TOTAL mA=1 Total Wire Resistance (R ) Total Device Load, Amps (I) !Voltage Drop ( E) EOL Voltage 37.8 109.74 0 0 147.541 14 `.-13 2C,S BPS 120VAC, DEDICATED , ) (BY OTHERS) 8 2C,S,V,V 2C,S,V,V Cl 2C,S,V,V S1-1 75cd V-1 1 /4-W S1-2 S1-3 15cd 15cd V-2 1 /4-W AHU D,2I TSM 2C,S,V,V S,V,V S1-4 S1-5 15cd 15cd V-3 1 /4-W S1-6 75cd V-4 1 /4-W S1-7 75cd V-5 1 /4-W EOL S1 1,443 19.301434861 147.541 (WL * 2 ) * (Rift) (Total Cct Load) 1(E= I * R) (20.4-E) 7.45; 0.15; 1.101 19.30 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110VAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE L. 0 9 aaaa< z Oz Q OJa (1)o z Z <Wo w Z2 (1)cnQ D F- ° aC-S owN ac 0 0 w z J w J 0 z 0 z Cin z 0 0 J 0 LU >- (1) (1) ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/ 15/ 1 1 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER: 55223 c SHEET FA -03 'SH;PSKIN AND ALPACA GIFTS' STORE LIGHTED WINDOW DISP >-w 0O 0< ›- C 0< 00 j c < (J) (2' MEN'S LIFEST LE AIR CARE Li CLUSTER TABLES I I j I II u / SHA'APOO F i U7 0 0 RETAIL 1100 LIGHTED WINDOW DISPLA' 4' EXPERIENCE TABLE(SEATING) EOL S1 S1-7 k75ccl V-5 o- S,V,V SHAMP CONDI T 0/ MAKEUP CHAIR TRAVEL TOWER SHAMPOO/ STYLE/ STYLE/ CONDITION FINISH FINISH i Y / \CHDRAIR/ER \ J MANICURE // ,/ // // // // TREE TMENt 103 S1-5 15cd V-3 L r 2C,S,V,V b C.{0.S.( ENTRY 102 S1-4 15cd SHOWER 105 I// i / PEDICUREAHU // // // // // // // // \ 2C,S,V,V' --o 2///i/ /, // /ice/r 4 S1-3 15cd V-2 TREATMENT 2 106 S1-2 \x, 2C,S,V,V 15cd RESTROOM ) 104 // // // LAUNDRY/BREAK 107 I 2C,S HAL 'OF S1-1 75cd V-1 D� TO NEAREST EXISTING DATA LOOP D6 Ea 0 E. P— UP 'BATH AND BODY WORKS' STORE FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 3 0 DESCRIPTION SHOP DRAWINGS DATE 04/15/11 za<aaK 0 W Oza)) _IOJ� (/) Z (/) >. '�CWzz WCO CO 1-11‘_ (i) cCQ o g 0 W N W No > " W cc LT. SCALE; 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/ 15/ 1 1 BACKROUND PLAN PROVIDED BY: 1013 NUMBER: 55223 J SHEET FA -04 221 SOUTHCENTER MALL ASSOCIATED PERMITS 17-F-175 13-F-136 11-F-085 17-S-189 13-S-133 13-S-130 11-S-089 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review **PLEASE PRINT** .,�^ �,n King Co. Assessor's Tax lN�o.:' /� Site Address: j7 \ o V l I l C€ ` Y m \` Suite Number. 10 LW Floor Tenant Name: ) )i h C_� 5Yrieti New Tenant? ❑ - Yes ❑ - No Property Owner's Name: Wes -a Mailing Address: Yviari mer\'r City State Zap CONTACT PERSON -if there are questions about the submittal. C.,11.Cd\--VC Name: 1011' 4k Day Telephone: - • - Company Name: an fe Wtsk-er-hoo ,' Mailing Address:?If)SAX 12\\re_ • Y\IV ,\\ C_re 1 v0P� City State Tip 4 1' E-mail Address: NICET III number: a/ top ' OSI I•� Fax Number: Contractor's City of Tukwila Business License number Total number of new/relocated devices or sprinlder heads: O % Valuation of Project (contractor's bid price): S '7O•`'LJ��yy�� Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construetion — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature:, Print Name: Plan Permit App.doc Date: /'2g'17 ICC} -99.0)01 YScn Day Telephone: z-iZS 1.700009 8/22114 TFDFPForm 8 4.61.W% JPZMEC CITY OF TLKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-5754407 Date application accepted: FIRE PRO 1'ECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION Z rl Zq 3 O/ 3 0 King Co. Assessor's Tax No.: `� ` Site Address: 22\ ( S U k f ia/ - f -0 31L'0 aFloor: Tenant Name: , V New Tenant? Yes ❑ - No Property Owner's Name- C Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: KARINA VELIZ Company Name: GUARDIAN SECURITY SYSTEMS, INC Mailing Address: 1743 – 1ST AVE S E-mail Address: kveliz@guardiansecurity. com Valuation of Project (contractor's bid price): S Day Telephone: 206-734-6276 x229 City SEATTLE, WA 98134 State Zip Fax Number: 206-341-9928 Scope of Work (please provide detailed information): l/L(�(�( Liv V L CUIA.-moi • PERMIT APPLICATION NOTES Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CER1'1tY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING�. R OR AUTHS ' • ED AGENT: Signature: Print Name: C V ( l V e ( Plan Perrnrt App.doc ILDate: ' l ` 1 Day Telephone: /-l1 L( • � —L Cl " U ? l 5/]4/]0 Inll FP Form 8 4 tit SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 2.'2._\ Tilekceyil-t ' !1 1a t Suite Number: (D ) Floor: Tenant Name: CeO ,� " Q—• Property Owner's Name: V', S WX44, Wa'1[%qprert+- C r6 )p New Tenant? ❑ - Yes ❑ - No Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: k CICX S)iii)1 )1 J" nsfl Day Telephone: Company Name:11A?� �l r•P_'t—PC' �'�c�Y1 Mailing Address: RD aCX \2._11 l f 1 b.)/N\ mDL. City , 1tate Zp E-mail Address: r`s /�. Fax Number: -}2�' g'� • g dg Total number of new/relocated devices or sprinkler heads: l� Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): feeloa•1 - (3) 14eaa..s �1 b7 Il-cackS and PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: f c/C JSi(a Rabin j cin Date: to ' q- !J Day Telephone: 4/24•1157-76651 Plan Permit App.doc 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Cache 221 Southcenter Mall Permit No.: 13-S-133 Date: June 17, 2013 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • Maintain a 4 ft. clear space around the sprinkler riser for emergency access. • An electrically supervised post indicating valve (PIV) is required. • PIV shall have the building number served by the PIV stenciled vertically in 3 - inch high white numbers on a "safety red" background, facing the direction of vehicular access. • The height of the fire department connection (FDC) shall be 36 to 48 inches above grade. • The FDC shall have a downward angle bend of 30 degrees with a 5 -inch Storz connection and a Knox locking Storz cap. • Install listed water shields on in -rack sprinklers. • Installation of all electrical pre -action system components requires a separate fire alarm permit and an electrical permit. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Tuscan Sanctuary & Spa 221 Southcenter Mall Permit No.: 11-S-089 Date: April 26, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3..6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. 1 . v • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Permit No.: Date: Reviewer: Lush Cosmetics 221 Southcenter Mall 17-S-189 October 9, 2017 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. NMubcr of Pages (including, Cover) 06/04/2013 13:49 4254016695 FAX TRANSMITTAL CROWN FIRE PAGE 01/01 Fax No. CROWN FIRE PROTECTION, INC. tom: Company MEM 6.4.13 Fire Prevention Bureau Tukwila Fire Department / Al Demo Permit 1 206.575.4439 [7 Urgent El For Review 0 Please Comment 0 Please Reply Cristae Ogland PH:425.481.7669 FX:425.481.8695 Comments Please provide a demo perrnit to remove (5) fire sprinkler heads and the piping under the existing me7..7anine that is being removed at the Cache project located at 221 Southcenter Mall. The building permit number is D13-122. Please let me know if you have any questions or need any additional information. Thanks TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address for shut- down hutdown or restoration approval. kir P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8_695 TYPE '01' GYP.BD. 10'-0" A.F.F CEILJNG TO BE PAINTED . k r _ TYPE '01' GYP.BD. 9'-0" A.F.F CEILING TO BE PAINTED_ EGGSHELL WHITE - RE; MATERIAL SCHEDULE A-105. PT -1 CORRIDOR HEADER TO BE AT 7'-4'A.F.F. Design per NFPA 13 — Ordinary Hazard Group 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions o i5 — Relocate Reliable Model G-56 165° Standard Response Pendents 1/2 x 1/2 o — Add Reliable Model G-56 165° Standard Response Pendents % x % • E — Existing no change /l//l///Wile ll//ll/l/Il/8//011/IIMMll mg/ Amor. 77riirrrrrriiriiairfi/MY 5iillrrirAZ. 15 ntimiriirrriiiriiirii rririni,7 Mar• ill t7 rrrrrtrrririr: ////1/////11/1//1/////// /1717��/�1�10�//1o/fOII/////1//1//1//1/////////1/%/ fi �% PE 'Al GYP.BD. -e- 'IF 1'-0" A.F.F. CEILIN TO BE PAINTED EGGS ELL BLACK ;nos TYPE 'Al' GYP.BD. 10'-0" A.F.F. Without C c mfnients As Noted in Red Per The Attached Letter These -plans -have been reviewed bV The Tukwila Fire Prevention Bure:avr for confarmancf, with current City standards. Accet .Jlice is :;uhjec,' ' errors and omissions vqhich co not authorl:.r v.ci72tion:3 of adopted standards ant ThF for the adequacy of cies, totalM h die designer. to cheEe drawings after Additions,C,c..aUr,;;.,, ..,. :�.�niiUi.. this date rvrii! 'r : "CepCaPCe and wiii require a resubmltual r= ui.r,ac ;or, tib equent approval. Final accen{ r,ce is su ieci tofu dela test and inspection by TThe l iFire are•! n oa Bureau. l le Tltl��e5. Ali~ .c .. �.iV� t E Date: 10-0- Fle ead rink! roil ................ �`�` Corrugated stainless steel hose with stairiless steel bras :;�; ,. avh Able in 2', 3',4',5' & 6' Iegnths . . yes s;• Multi -Port Bracket • Adjustable Flub i" FLEXHIAO I INDUSIRIESLJ Flexhesd'- omn-iercial Ceilirig Unit T -Bar Ceiling Installation ' Model 2024,2036,2048,060,2072 /41 /40 /f/ 0 // %%¢ o,/0 /j / A, A 111/rf0 of !/ r /II Fr 40 Fij9 Y/f, %/ ror Aq1 HOP /4: Prre 1/1 TRACK LIGHTING TO BE SU 'MOUNTED INSIDE RECESSED POCKET PROJECT LOCATION WKWILA FIRE 1;EPARTMTT fit' Piease caN 206-575-4407 and give this Fire Permit No. S- and e;,:asct kick;: s 3^J for shut- down or restoration approval. :a613a9i[�lilss�i TYPE 'Al' GYP.B CEILING TO BE PAINTED EGGSHELL BLACK TYPE 'Al' GYP.BD. 10'-0" A.F.F.': PT -2... CEILING TO BE PAINTED EGGSHELL . BLACK - RE: _• -. MATERIAL . SCHEDULE A-105 TYPE 'Al' GYP.BD. . 10'-0" A,F.F. 0 CEILING TO BE f.? PAINTED EGGSHELL PT -2. Welatigasteem LUS' FRESH ANDMADE C LEVEL 1- SUITE 221 John ;Abel 9760-0591.0G: -1.6.w1.3 ..> -!mown Fire Prate a; Ire • a a rfi P17 g.. ill/ N. REFLECTED CEILING PLAN I SCALE: 1/4* =1'-0" CROWN: FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Lush Cosmetics Space # Tukwila, WA DATE: c4.2 s,1-1 DRAWN: SCALE: I PAID SpP2j201i T UK HILA FIR . ?9 d o� H Y EC DDI N M I S EET \UN3E SHEET TITLE FA -01 SYST -N v ATIO FA -02 TYPICAL WRING A\3 VOU\ TI \G DETAILS FA --03 SYSTEM CALCULAT 10\S A\ SI\GLE LINE DIAGAv FA -0 FIS ALAV SYSTEv PLA\ SHEET INDEX i( Without Comments As Noted in Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and oInisslons which do not authorize violations of adopted 7':3ndards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletionh -._, revisions to these drawings after thte, dot- i rn "nid rt,is Pcceotance and will require a for suosuauerit approval Final acceptance I:- .5uoJect to field test and Inspection by The Tukwila circ Prevention Bureau, Date: ' -11.4 1 ajr� WIRE SCH TUKII.Vi ,., PRE p: EPARTME't3TT ?,-."),:1-3"/5-41407 and r'!4 e. yi rill r-iyr9 1t NO. S- aldress for shut- down or restoration approval. 3., LE AN CO\QUIT FILL C AT WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC - FEED TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) C' STROBE SYNC - RETURN TWISTED PAIR WITH SHIELD #14 FPLP RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPLP RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPLP RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPLP RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPLP RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPLP RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIE`DED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSCCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY; ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY E 1 1 2 2 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS E REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT SMOKE DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S BOX VERIFY IN FIELD FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S BOX CEILING TENANT J -BOX DE (EXISTING) F.B.O. F.B.O. VERIFY IN FIELD END -OF -LINE RESISTOR • A.F.F. ABOVE FINISHED FLOOR N/A N /A N/A N/A E EXISTING DEVICE N /A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N /A N/A N/A NOT APPLICABLE N /A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A N/A 1J/ A GREEN AS BUILT REMOVE N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LE LL LUSH FRESH HANDMADE COSMETICS SUITE 221 ii IJ - -/ 1 macy r.' Y-1 FETA, SEARS E s, PAID � SEP 13 2017 ,% TUKWILA FIRE SITE PLAN c�-- Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ir7 cls (f) LU r - >- w N 0 a_ LL G SHOP DRAWINGS 0 w 0 0 L.LI 0 0 z 1 w cr Li... 1 0 0', 0 CV CV co LU co no-) J Q < 0 z -±- w (!) Q w O� 0 0 co cv (SCALE: NOT IT SC. Lc DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:009/011 17 BACKROUND PLAN PROVIUr a JY 'OB NUMBER: _036, - 1 SHEET FA- o THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TUBE OUTLET SAMPLING TUBE INLET SAMPLING DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-60HZ - DEDICATED EMERGENCY • FROM EXISTING MAIN FACP C CABLE C' CABLE (-) (+) (-) (+) LiL�i INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 3.6k EOL HARD LID CEILING HARD LID —\ SPEAKER SUPPORT TILE BRIDGE NAC S4 NAC S3 NAC S2 NAC S1 PAD -3 POWER SUPPLY WIRING DETAIL 4" SQUARE DEEP BOX WITH 1-1/2" EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE & STROBE CEILING MOUNTING DETAIL FROM REMOTE POWER SUPPLY FEED FROM EXISTING VOICE CIRCUIT (V CABLE) RETURN TO EXISTING VOICE CIRCUIT (V' CABLE) 0 (+) (–) STROBE SPEAKER FROM PREVIOUS ADDRESSABLE DEVICE HFP-11 TBI 000®TTO 0®10 NO COM NC rpt 00 TO FAN SHUTDOWN EOLR 470 m SWITCH + — INPUT LED TSM -1 0 TO NEXT ADDRESSABLE DEVICE NO ® COM B HTRI-R NC ® 0 O TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL (+) O STROBE (+) O STROBE SPEAKER (+) (–) SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS TO NEXT DEVICE OR END OF LINE Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved : rr) ON 00ONN..1 O t - (r) LLI I-- �� LU 1ST AVE. SO., (1) 0 LL1 LLI () a LU J LLI Ch m 0 > 0 LU cY DESCRIPTION SHOP DRAWINGS LU 1- 0 0 0 (S-CALE: NOT TC SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 009/01/17 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 2636i - 1� SHEET FA -02 A B C D E F G H 1 J K FIRE ALARM BOOSTER Project: LUSH FRESH HANDMADE Panel: EXISTING BPS PAD -3 Date: September 5, 2017 Module/Device Fa P ADD SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 Current Load: 15 0 Standby: Alarm: TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 3649 Total(A)= 15 Total(B)= 3789 CALCULATION Device Type Qty Amps Total Amps Total Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). HFP-11 0.0022 0.0022 0.0023 0.000 FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps A B C D E F G H 1 J K FIRE ALARM BOOSTER Project: LUSH FRESH HANDMADE Panel: EXISTING BPS PAD -3 Date: September 5, 2017 Module/Device POWER COSMETICS REMOTE Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 3649 Total(A)= 15 Total(B)= 3789 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 3789 Total current ratings converted to amperes (line D x .001) 0.015 3.789 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 0.36 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.3156237 Add lines G and I Total Standby and Alarm AH 0.6756237 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.81074844 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 CALCULATIONS Notification Appliance Circuit Detail PROJECT: LUSH FRESH HANDMADE COSMETICS Panel: EXISTING BPS PAD -3 REMOTE POWER SUPPLY__ Date: September 5, 2017 Wire Resistance 2.58 CURRENT TOTAL= 3649.00 SET -MC -CW @15cd 1 SET -MC -CW @30cd 2 SET -MC -CW @75cd SET -MC -CW @95cd 2 ZR -MC -CW @15cd DEVICES 5 69 0 111 111 200 400 264 0 69 138 TOTAL mA= 649 14 378 22.73 649 Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage (WL*2)*(R/ft) (Total Cct Loa d)- (E=1*R) 24 E) 1.95 0.65 1.27 22.73 1500 DEVICES 1500 S EOL S3 S3-1 S3-2 30cd 75cd D EXISTING TENANT J -BOX S3-3 S3-4 75cd 15cd D,I -0 IHT-RI 21 • TSMI SINGLE LINE DIAGRAM S3-5 15cd FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. r) o co Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved L1J RELEASE/REVISIONS REV. BY: 0 m 0 i DESCRIPTION SHOP DRAWINGS DATE N 0 0) O 0 w co O z w CO CO 0 01-6 LU ao)z C� o J o >, w z 0 w� Zw < CC Q 1— Iwco �� W ©1— CC o co LL `\' 1 J D 0 0 LLQ rSCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 009/01 / 17 BACKROUND PLAN PROVIDED BY: _JOB NUMBER: 26367-1.2 r- SHEET FA -03 TO TENANT J -BOX TO TENANT J -BOX D S,V Sr,03 PRP F1/0)SilaVES : FFP FIXED Sh121.VES •12.‘24. A2x24. -••• • ; PPP MID SELVES ir 24. S3-5 15cd S3-1 WATER COOLER xi 5 • • 30cd LOCKE imuzEff4DED:TisfiFRflTERO.r 4.9%.24' '3JVS j KNOT WRAP CANVAS Lu BAGS 0 PERFUME GIFTS — GIFTS - - GIFTS ADJ. TENANT 0 SCALE 1 , STORAGE L -- C.HT: 10'-C CEILING - F FINISH CASH S S3-2 75cd mum ..• 111 SOAP CANVAS BAGS IMPULSE CAT: 1 '-8° CEILING P2 FINISH CONSULT I Da0 • ! 1 :6‘; . ; CART ; ; • • ,•1...!; ; • •• V CANVAS BAGS _ CAR* \-1—••••, I! • •••• K K -•(,0` • 5:11' :1 16 DEMO SINKS , ------- WINDOW DISPLAY I ! !- ! ! f -FEATURE S3-3 75cd 1 ! C,E,101 c1- • , .; • I_ -1 ! ' • I • C.HT: 10.-0" CEILING FINISH FLEXIBLE FLEXIBLE CONSULT FRESH PAN FLOATING SHELVES 1 SHOWER r- ; MOUTH L. k SKINCARE 1 i • • FRESH (3 FRIDGE / MASSAGE .• , • ' - • / / FIRE ALARM SYSTEM PLAN ADJ. TENANT FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC SHUTDOWN. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 11 11.*. !!!!•••• 4.1? s ‘f.;;-• J04'04 cQ 0-• r) j 1_1_1 RELEASE/REVISIONS !REV. BY: DMG 1 DESCRIPTION SHOP DRAWINGS DATE r`•-• •••••...., .-- 0 •-•.., 0) 0 (-) - - <<" ..- -....... ..,-- iiJ SCALE: 1 / 4" = 'C'' DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 009/01 7 BACKROUND PLAN PROVIDED BY :..JOB NUMBER: 26367-1,i 1 SHEET FA -04 DDITION N rA. Sea tie/ t hoot Comments 51( As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prev n Bureau au for conformance with current City standards. Acceptu":r,, is subject to errors and omissor-,s which rr rj _ •ithorize violations of adopted stantards and dr6En.nnce , T,,e r s uns1O!Iity for the adeq lacy o1 des! :n f' .: : totally wirfo e designer. Add:{+ofS, d4i¢'rc:i ;a:,; to these drawings after this ('C VJl►I \'C d .'f. :r":::%lc'.1Cc :ijl!! vv!it require a resubmittal of revises: cirawiNtd: .,..'resent approval. SHEET \Uv3ESHEET TITLE FA -01 SYSTE v I\FOS 1ATION FA -02 TYPICAL WHI\G A\3 V OU\TING DETAILS -A-03 SYSTEv CALCULATIO\S A\D SINGLE LINE DIAGRAM FA -04 FIDE ALA v SYSTEM PLA\ SHEET INDEX WISE SCHEDULE A\D CO \ D U IT FILL C HATT WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARA RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX EX EX EX 5 4 SYMBOL DESCRIPTION MODEL The Tukwila Fire Prevention bureau. Date: (0-I k - (3 By: k:W► si 1 T .. nb • NOTICE 4 completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. n - F- wt'i 3 S -.arld_exact t9�i; f,,_+.�.`-s-for-shut- down or reaor at on app.i oval. MOUNTING HEIGHT BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-11 W/ SIEMENS EX (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP w/ 1G RING CEILING ®EX DUCT DETECTOR D AD2-P W/ SIEMENS DUCT HOUSING HFP-1 1 DET. VERIFY IN FIELD TSM DUCT DETECTOR EX TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HTR -R EX INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY 11'1 FIELD FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX W/ 1-1 /2 EXTN CEILING FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N /A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM 3 LEVELS 171,2755: 'a'al`.Ea�p.S 6.1 ,«.nW%S3 YALE maty 4 LEVELS 2 C,4C7 f GU B.JaTO T -T 1., 4' D TO CO _._._. s•a=. CACHE (221) / SPACE #640 -1- A= 'S E.Sc X11 L IJ I ... JCPenney PAID JUN 112013 TUKWILA FIRE rr W e cc D 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS 1 DATE M C. 0 0 0 aaaa< 0 (0 ZWco D v,- < Q PnZ < 1O CC cc w 5 05 W rr LT_ 1- T N 0 0 W N >El N /SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE:06/07/13 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN CC 00 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved .JOB NUMBER: 5221-1} �► SHEET .\ V FA -01} \,. 12OVACC-60NZ DEDICATED EMERGENCY THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NEPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE: FON ADIX00NA1. SPECSICATIONS SEE PRODUCT DOCUMENTA1Nk1. *CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC HEWIsglifiD TD NEXT ADDRESSABLE (+ DEVICE STOP IF LAST DEVICE - rRDN XLS CONTROL PANEL (+ DR PREVIOUS ADDRESSABLE DEVICE - O 0 0 0 HTRI-R Igri e: 1 O 0 NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C—CABLE C—CABLE El PAD -3 no INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX + - 1 2+ 2- 2 NC C NO + - + - + - + - + - O 0 3.6k EOL • (-) (+) SPARE SPARE SPARE F'D ❑ FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (—) I 0 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. • 0 m C) m 0 P1 m O (+) WIRE DESIGNATION: NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR WITH SHIELD #18 FRJFPLR RED (JACKET) 'CONTACT RATINGS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 F r n GROUND L- N 0 HTRI-R 0 (+)) TO NEXT DEVICE OR (-) 11 POWER SUPPLY & RELAY MODULE WIRING DETAIL FROM PRECEDING SPEAKER < OR FIRE ALARM CONTROL PANEL < (+) (+) 11 C 11 (-) > STCP IF LAST DEVICE ____> DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL SPEAKER 0 0 1:1:1:1:111:1:1 0 STROBE Q IDE -i CIRCUIT QO❑ (-) STROBE CIRCUIT STROBE Q 0❑ 0 0 a 8 11 - �NCN[I ON " I:11:1:11 1:1:1 out (-) V (-) SPEAKER CIRCUIT (+) (+) D=ri LI �El STROBE IDE ll ' CIRCUIT SPEAKERISTROBE ❑o — O 0 M 0 O , i DESCRIPTION DATE M ' 1 ' r ? a" 0 +- ASCOIFON f (0 Yl//' 316 I 1:1:1:1 1_1:4:1* 0 -moi i- Ni {may; 53 z aaa<a -- 10)' (-) ❑I1 (-) STROBE SPEAKER CIRCUIT SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS (+) (-) SPEAKER CIRCUIT 5 TO NEXT APPLIANCE 5 OR 24K (EOLR) S TO NEXT SPEAKER OR END OR LINE RESISTOR 24K (EOLR) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +32' F (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —1 — FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPUCATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL HARD LID CEILING '�. SPEAKER SUPPORT -ILE-- BRIDGE HARD LID > TO NEXT ADDRESSABLE DEVICE 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSI❑N CEILING MOUNTED SPEAKER/STROBE • • • SPEAKER STROBE MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX \ JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 0 0 TO NEXT DEVICE -- CADDY BAR SMOKE/HEAT DETECTOR — .IEJI SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright: 2013 by Guardian Security Systems, Inc. All Rights Reserved ca 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE M 1` 0 (0 0 z aaa<a c0 co Z w co O r1T 0� Q PZ QJE- w �z o cc I w�Q' U < ~ w� = T N N 'CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 06/07/13 BACKROUND PLAN PROVIDED BY: `JOB NUMBER: 5221-1) SHEET +�� FA -02 J Notification Appliance Circuit Detail PROJECT: CACHE Panel: EXISTING PAD -3 POWER SUPPLY Date: June 7,2013 .U..iiii'',,,;J:.,,ki •i3,!.,11(‘',1*i ' thquii- -. !':' ; , : 2 SET -MC -C ©15CD 87.5 2 SET -MC -C ©30CD 131 0 :SET -MC -C ©75CD 222 1 SET -MC -C ©95CD 292 0 iZR-MC ©110CD 259 4 ZR -MC ©15CD 69 0;ZR-MC ©30CD 98 . , 0 ZR -MC ©75CD 175 TOTAL mA= DEVICES=: ;Total Wire Resistance ( R) Total Device Load, Amps (1) ,Voltage Drop ( E) EOL Voltage PROJECT: CACHE Panel: XLS-V Date: (June 7, 2013 ir 19 !70.7V1/8 27 70.7V1/4 0 i70.7V1/2 0 70.7V 1 DEVICES= 46 !Wire Resistance 2.58 CURRENT TOTAL= I 1005..00 175 262 0 _ • 292. 0 276 01 .„.. 0 10051 14 187 23.03 1005 (1/1/L 2 )* (R/ft) (Total Cct Load) (E= I * R) 24 - E) 0.96 4$1.01 0.97. 12.3.03 Notification Appliance Circuit Detail r • •LWire Resistance 2.58 CURRENT TOTAL=r#REF! 1.8 34.2! 3.54 95.58 0 0 TOTALrnA=i 129.78! 14 Total Wire Resistance ( R) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 1,243 19.56760665 1•'• 129i78 WL *_2 ) * (Rift) 6$1 (Total Cct Load) 043 1(E= 1* R) 0183 (24 - E) 2317 cu Iu fi) 743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 (7) LU LLJ Cf) uJ _J 1.1_1 SYSTEM CALCULATIONS 120VAC, DEDICATED (BY OTHERS) S,V,V S,V,V S1-1 15cd V-1 1/4-W S1-2 S1-3 30cd 15cd V-2 1/4-W S1-4 15cd 8 EX (HALLWAY) V,V S,V,V S,V,V S,V,V S1-5 15cd V-3 1/4-W S1-6 30cd V-4 1/4-W 81-7 15cd S,V,V S1-8 15cd S1-9 95cd V-5 1/4-W EOL S1 REV. BY: EXISTING SIEMENS PAD -3 Signal Extender Panel Ba e oad Calculations z 0 a. (..) (1) Lu c) SHOP DRAWINGS CurrentLoad: Standby: Alarm: to '--- 1, 0 (0 0 2 <<<<< Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -C ©15CD 2 0.0875 SET -MC -C ©30CD 2 0.131 SET -MC -C @75CD 0.222 SET -MC -C ©95CD 1 0.292 0.292 SET -MC -C ©110CD 0.259 ZR -MC ©15CD 4 0.069 0.276 ZR -MC ©30CD 0.098 ZR -MC @75CD 0.2 0.03 Amps 0.598 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 0.598 Amps For 5 Minutes 0.050 Amp -hours 25% Derating = 0.963 Amp -hours Total System Current Load: 0.963 Amp -hours Battery Pair to be Used: r 12VDC Amp -hours 7.2AH Notification Appliance Circuit Detail PROJECT: CACHE Panel: EXISTING PAD -3 POWER SUPPLY Date: June 7,2013 .U..iiii'',,,;J:.,,ki •i3,!.,11(‘',1*i ' thquii- -. !':' ; , : 2 SET -MC -C ©15CD 87.5 2 SET -MC -C ©30CD 131 0 :SET -MC -C ©75CD 222 1 SET -MC -C ©95CD 292 0 iZR-MC ©110CD 259 4 ZR -MC ©15CD 69 0;ZR-MC ©30CD 98 . , 0 ZR -MC ©75CD 175 TOTAL mA= DEVICES=: ;Total Wire Resistance ( R) Total Device Load, Amps (1) ,Voltage Drop ( E) EOL Voltage PROJECT: CACHE Panel: XLS-V Date: (June 7, 2013 ir 19 !70.7V1/8 27 70.7V1/4 0 i70.7V1/2 0 70.7V 1 DEVICES= 46 !Wire Resistance 2.58 CURRENT TOTAL= I 1005..00 175 262 0 _ • 292. 0 276 01 .„.. 0 10051 14 187 23.03 1005 (1/1/L 2 )* (R/ft) (Total Cct Load) (E= I * R) 24 - E) 0.96 4$1.01 0.97. 12.3.03 Notification Appliance Circuit Detail r • •LWire Resistance 2.58 CURRENT TOTAL=r#REF! 1.8 34.2! 3.54 95.58 0 0 TOTALrnA=i 129.78! 14 Total Wire Resistance ( R) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 1,243 19.56760665 1•'• 129i78 WL *_2 ) * (Rift) 6$1 (Total Cct Load) 043 1(E= 1* R) 0183 (24 - E) 2317 cu Iu fi) 743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 (7) LU LLJ Cf) uJ _J 1.1_1 SYSTEM CALCULATIONS 120VAC, DEDICATED (BY OTHERS) S,V,V S,V,V S1-1 15cd V-1 1/4-W S1-2 S1-3 30cd 15cd V-2 1/4-W S1-4 15cd 8 EX (HALLWAY) V,V S,V,V S,V,V S,V,V S1-5 15cd V-3 1/4-W S1-6 30cd V-4 1/4-W 81-7 15cd S,V,V S1-8 15cd S1-9 95cd V-5 1/4-W EOL S1 REV. BY: 0 m 0 z 0 a. (..) (1) Lu c) SHOP DRAWINGS DATE to '--- 1, 0 (0 0 2 <<<<< 0 co Z w g. 0 IJO < z 00 LU <2 =Pa Lu z cc ci 0 2 cc w 5 0 5 < al _IF - cc V) cr 0 0 w z J z (7) 0 zz0 0 (.1 0 (1) ›- fcCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 06/07/13 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM JOB NUMBER: 5221-1} r- SHEET FA -03 Proprietary and Confidential, Copyright( 2013 by Guardian Security Systems, Inc. All Rights Reserved EX (HALLWAY) J_. (J V,V' S,V,V TR Y S1-9 95cd V-5 EOL S1 SAES OR I �I f,,uyrrr.T :N0 S,VLV' —0 I-. ;81-7 15cd F I - L., ; s,v,v, b S1-6 30cd V-4 H1 7 I PR TING P 00V H1 AREA S1-4 15cd a� v,rr FITTIN 6 ROOM n svV'—a TOILE T DOR 8 S1-5 8d V-3 30 S S1-2 3Ocd V-2 FIRE ALARM SYSTEM PLAN 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS (REV. BY: 0 DESCRIPTION SHOP DRAWINGS DATE 06/07/13 2CCC<C 2 O co ;t co Zw0 Q 0 (7) Elm CD FY) Z (/) < --1 >m O Luiz (I) w< cc w w� nc �� N 1.1.1 SCALE: DRAWN BY: D. GARCIA DESIGNED BY: K. HEIGHTON DATE: 06/07/13 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 5221-1} I. SHEET FA -04 Proprietary and Confidential, Copyright:: 2013 by Guardian Security Systems, Inc. All Rights Reserved \ �/ ADJACENT TENANT (fr`\ eisP RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP DEAN/ C-CLANP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JO/ST/TRUSS HANGER DETAIL NTS EXISITNG GYP. BD. CEILING TO REMAIN PAINT PT2 • NEW 24"x48" ACOUSTIC TILE LAY—IN CLG AT +11'-6" AFF. (STOCK ROOM LOCATION ONLY) (ACT1) AIWt b 4.0 .4 L;:i El Without Comments As Nott.,.. -,d in Red O Per The Attached Letter These plans have been reviewed by TheTukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to e.rrors and omissions which do not authorize v!otiOns of adopted standards and ordinances. The resp:v•isibilicy for the adequacy of de,sif s tot:,:ily with the designer. Additions, delet o elor6w Liles;:=:: cirMilgs after .thIs date. will k.fc:dric pc rJ1.,,,,Ifi(Q0€ a resubmIttal of f-.vis.eci fo; 5DqflL approval. Final acceptance is subject to field test and Inspection by Tne Tukwila Prevention Bureau. 3 1 ( Date:(0-( ADJACENT TENANT REFLECTED. CEILING / LIGHTING PLAN 1/4" = GYP. BD SOFFIT BOT.. PAINT PT2, GYP. BD HEADER BOT. PAINT Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 10 — Add Reliable Model G5-56 Concealed 155° Pendents Y2 x1/2 o 3 — Relocate Reliable Model G5-56 Concealed 155° Pendents V2 x 1/2 o E — Existing no change . CROWN FIRE -PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 : PH. (425) 481-7869 TUKWILA FIRE DEPARTMENT Piease call 206-575-4407 and give this Fire Permit•No. and exact address for shut- - ir tit down or restoration approval. Li Cache 1 221 Southcenter Mall Space 640 Tukwila, WA 98188 A 'on Sprit*.‘t1 'OtIghDge..004. ID ).3 5 2013 A AFIRE. ..1E.27ee,32 •PA JUN 0 • TUKWIL DATE: 6L(,,3 DRAWN: I ri SCALE: ' o f- I 1. 1111111171112111111111111 Imilill 1 1 AMAng-'. ' 1 11 - 0 immiffilliMm.= 1 TR 5 JI�I;.�) , g! ISI NI r.. ;�&]t v+5at. ' �; ::4, , ,24. yes rt,,'i; '. `l,'!. e r �rr,� �: � �'�:�7'•yx r v: --•-it thk immi iz�%i+t�dr��..�r:w`?�'.a_..C{rt,Y.ir.�S!21'_'•�y+.�i�.tc-rt'���t���-uJ...��_��.��i'�t�iy�z.'4. IP • • • mom •mo .ice __..Immo w ammo Ammo •s. ,t ••• c C.O.S.(E) REFLECTED CEILING PLAN SCALE: 1/41=1'-0■ E F G J RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS �—TOP WITH BSETSCREW 3/8' ALL THREAD RED HANGER DETAIL NTS • Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Dre"ention Bureau for cc f:Nrn==nce with current City standards. Acce :tan(L is;:i.b ect to errors and rnissionS which do not authorize violations of adopted tandards and ordinances. responsibility for the adequacy of design !'-'27.1'5 totally'with the designer. Additions; del tion:: r:r revisions to these drawings after this date w ll•void tt'i'•s 7,:ccept nce and w it require a resubmlttai of revised dra ,angs for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: `-1 -a,c, - t1 'By• Design per NFPA 13, Ordinary Hazard All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart ® 3 — Add Reliable Model F1 Standard Response 155 ° Pendents 1/2 x 1/2 o R11 — Relocate Reliable Model Fl Standard Response 155 ° Pendents 1/2 x 1/2 o 3 — Plug Reliable Model F 1 Standard Response 155 ° Pendents 1/2 x 1/2 • E — Existing 17 — Total RCP -0I 4' 0' 2' SCALE 1/4' = 1'-0' K VICINITY MAP 4 r!! LA FIRE DEPARTMENT Please ciA 2?<;,_•5755447 and F give this re Permit No. /1 -S- and exact address for shut- down or restoration approval. SITE PLAN 4111111 CROWN FIRE PROTECTION INCORPORATED. P.U. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Tuscan Sanctuary Salon & Spa Southcenter Mall 2-,;-1 Tukwila, WA AP TUKV DATE: L; 15 DRAWN: Ci SCALE: l: u RAID 18 2011 /ILA FIRE SHEET NUM3ER SHEET TITLE Er�A mscA F RE ALARM SYSTE K .`. ILA, WASH FA- 01 SYSTEIv INFORMATION FA -02 TYPICAL WIRING AND MOUNTI\G DETAILS FA -03 SYSTEM CALCULATIONS A\ D SI \GLE LINE DIAG RAI/ FA -04 FIRE ALARIv SYSTEM PLA\ SHEET INDEX 0 ‘,nl;thout Comments f;r Noted in Red Pe; The Attached Letter -e plans ray:: he_f • reviewed by The Tukwila Fire otion Burez ,..-iformance with current City ,rds. Accept?. cc ; - c-,.;biect to errors and ns which do : ,r o. ize violations of adopted is and ordinal,c The responsibility for the ;zoequaoy of design rests oraliy with the designer. Additions, deletions or rf',13i0M. to these drawings after t`,is date will void th`' T,- e7tance and will require a iittal of revises for subsequent approval. acceptance is subic' i to field test and inspection by Pire Psevt ° ^n Bureau. [._�--`''' �j,��� NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. F--aum of test will result 1 -,rillstrledfmn Fee and TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give the Fire Permit No. j - and exact address for shut- down or restoration approval. D U LE AND CONDUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END N SALON DDITION TON FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. g, FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 1 1 1 2 5 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD -3 -ENOL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HTR -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM SPEAKER STROBE SET -MC -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1 /2 EXTN FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F. B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND macyA 4 = VELS NORDSTROM 3 LEVELS EYPESSJ 171,275sf JAYES BT ISNE TOKYO TDKep ,AEETI GO-, LI 9r SS 117,, TN.E aPorls I �D MPB AN 3AlleCi ClOGE CASJA_ KING CD'.>UTY LBEARY jRED YEYEN (£RECEnS SLATE 4 CSD S I I CGGGIA GATE G GAUK a'L"FSAS b_. CN eot Root ARI.UET`E .h :SBUIE I EST Y rttn I ° �x `=r1 sm.," JAMA -INCE e S.AT1 STAPEJ K,FIZ_TN5.n1.ESS SAT_ ,_BS TAY S+-. YID IN 'WASILNCTCN £9f$Cw-N=t PALNIC S. AVEDA TUSCAN SALON (221) 9xEK SEES 9xC'( 5.4-x3 nem aASSN O LEG WENS 1.iCEtNi f EXSTING JCPenney 3 LC'GLG 276,458sf SEATS PAID APR 19 2011 TUKWILA fIRE 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 04/15/11 2<<aaa z O Z co < 03 (f) OZ z <W° `' W Z Z C/) cn Q I- cc �. Q Q cn-g O_ owN j LL I - <C 'GALE: NOT Z 0 0 Z W (i) TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE:04/15/1 1 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1,OB NUMBER: 552235.3 j SHEET FA -01 120VAC-60HZ DEDICATED EMERGENCY l THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' AIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NO1E FCR AMID:NAL SPECSICA1K1 S SIE PRODUCT DOC MNTA110N. *CONTACT RAT@NGS 4.0A 0 125VAC 4.0A 0 30VDC REM TD NEXT ADDRESSABLE r+ DEVICE STOP IF LAST DEVICE - FR011 XLS cZNTRIL PANEL (f DR PREVIOUS ADDRESSABLE DEVICE O O 0 0 mND` t J -� ' I et 1 HTRI—R I k4 e; 1 O NOTE: FOR ADDITIONAL SPEORCATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 0 PAD -3 00 INPUT INPUT TROUBLE WA.C1 NAC2 NAC3 NAC4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - 0 (-) (+) 'SPARE SPARE SPARE FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) 0 0 ASCVEFtt 11:I:I:111:1:1• POWER SUPPLY & RELAY MODULE WIRING DETAIL FROM PRECEDING SPEAKER < OR FIRE ALARM CONTROL PANEL < (+) (+) (-) N NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. a v S m z 5 m o m O m No 0 g m F� m (-o)(-) v (+)(+) v (+) TSM -1 0 0 WIRE DESIGNATION: NUMBER OF CONDUCTORS SE TYPE COLOR CODE TWISTED PAIR WITH SHIELD f18 FPI IFP.R RED (JACKET) *CONTACT RAT111CS 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. F GROUND L O O 0 0 rT , e HTRI—R I o0 /- .)) i (+)>TO NEXT DEVICE OR (-) STOP IF LAST DEVICE DRY CONTACTS TO VAV -_ FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL SPEAKER 0 LI STROBE 0 CIRCUIT QED❑ 0 0 I:1:1:1:111:1:1 I (-) STROBE CIRCUIT STROBE I1❑ ❑I1 1 %ED quo � , SHOP DRAWINGS 0 0 t - l ,_ \ WEEK u: 7 1- LO t I 1- o \ \._ .....' . 11'1:1:I I 1:1:1' 0 k I" (-) L- SPEAKER CIRCUIT (+) V (+) SPEAKERISTROBE 1 0 0 STROBE CIRCUIT (-) SPEAKER CIRCUIT SPEAKER STROBES & STROBES ONLY WIRING DETAIL TYPICAL WIRING AND MOUNTING DETAILS (-) SPEAKER CIRCUIT S TO NEXT APPLIANCE S OR 24K (EOLR) S TO NEXT SPEAKER OR END OR LINE RESISTOR S 24K (EOLR) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. +32' FF (0' C) TO 100' F (38' C) HUMIDITY: 0-93% RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR — FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS LISTED FOR MR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL HARD LID -\ CEILING > TO NEXT ADDRESSABLE DEVICE HARD LID —\ SPEAKER SUPPORT TILE BRIDGE 4" SQUARE DEEP BOX WITH 1-1/2' EXTENSION CEILING MOUNTED SPEAKER/STROBE SPEAKER STROBE MOUNTING DETAIL JUNCTION BOX MOUNTED ON CEILING FLEX TeintrairOl JUNCTION BOX MOUNTED AGAINS CEILING SUPPORT TO NEXT DEVICE —CADDY BAR ,E31 SMOKE/HEAT DETECTOR 1 SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2010 by PAID APR 19 2011 TUKWILA FIRE ‘i/7I-2o3 Guardian Security Systems, Inc. All Rights Reserved s z FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 0 M 0 DESCRIPTION SHOP DRAWINGS LJ \ 1- LO o \ 0 o«a<< z J 0 riLQSS co c z z < w 1Q w z z UCC te_ ¢owff Z O 0 z c� z J U 6ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/ 15/ 1 1 BACKROUND PLAN PROVIDED BY: _JOB NUMBER: 55223_1 1 SHEET FA -02 HTR -R, Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.002 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps ENS. RAD gn axle uletions Current ,o id:: rib irrl Device Type Qty Amps Tota 1 Amps Total Main System Board 1 0.03 0.03 0.030 0.030 SET -MC -C @15CD 2 0.0875 SET -MC -C @30CD 1 0.131 SET -MC -C @75CD 2 0.222 SET -MC -C @95CD 0.292 SET -MC -C @110CD 0.259 ZR -MC @15CD 2 0.064 0.128 ZR -MC @30CD 0.098 ZR -MC @75CD 0.2 0.03 Amps 0.158 Amps Standby Current Load: 0.03 Amps For 24 Hour 0.720 Amp -hours Alarm Current Load: 0.158 Amps For 5 Minutes 0.013 Amp -hours 25% Derating= 0.917 Amp -hours Total System Current Load: 0.917 Amp -hours Pa td be' Used. 12VDC Amp -h© 2AH EX (HALLWAY) TO NEAREST EXISTING , IHTR-RI DATA LOOP t D -o PROJECT: Notification Appliance Circuit Detail AVEDA TUSCAN SALON Panel: PAD -3 POWER SUPPLY Date:1 April 18, 2011 Wire Resistance 2.58 CURRENT TOTAL= 878.00 SET -MC -C @15CD 1 SET -MC -C @30CD 2 SET -MC -C @75CD 0 SET -MC -C @95CD 0 ZR -MC @110CD 2 ZR -MC @15CD 0 'ZR -MC @30CD 0 ZR -MC @75CD DEVICES= 7 2221 292 259 64 98 175 TOTAL mA= 'Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop ( E) EOL Voltage 1751 131 4441 0 01 .._ 128 01 0 8781 14 162 23.27 ( WL * 2 )* (Rift) (Total Cct Load) 1(E=I*R) 24-E) 878 0.84 0.88 0.73 23.27 Notification Appliance Circuit Detail PROJECT:: AVEDA TUSCAN SALON Panel: XLSV Date: j April 18, 2011 Wire Resistance 2.58 CURRENT TOTAL=1#REF! 21 170.7V 1/8 31 70.71/114 0 170.7V1/2 0 70.7V1 DEVICES=! 52 SYSTEM CALCULATIONS 2C,V,V 1.81 3.54 0! 0 TOTAL mA=1 Total Wire Resistance (R ) Total Device Load, Amps (I) !Voltage Drop ( E) EOL Voltage 37.8 109.74 0 0 147.541 14 `.-13 2C,S BPS 120VAC, DEDICATED , ) (BY OTHERS) 8 2C,S,V,V 2C,S,V,V Cl 2C,S,V,V S1-1 75cd V-1 1 /4-W S1-2 S1-3 15cd 15cd V-2 1 /4-W AHU D,2I TSM 2C,S,V,V S,V,V S1-4 S1-5 15cd 15cd V-3 1 /4-W S1-6 75cd V-4 1 /4-W S1-7 75cd V-5 1 /4-W EOL S1 1,443 19.301434861 147.541 (WL * 2 ) * (Rift) (Total Cct Load) 1(E= I * R) (20.4-E) 7.45; 0.15; 1.101 19.30 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110VAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS IREV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE L. 0 9 aaaa< z Oz Q OJa (1)o z Z <Wo w Z2 (1)cnQ D F- ° aC-S owN ac 0 0 w z J w J 0 z 0 z Cin z 0 0 J 0 LU >- (1) (1) ALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/ 15/ 1 1 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved JOB NUMBER: 55223 c SHEET FA -03 'SH;PSKIN AND ALPACA GIFTS' STORE LIGHTED WINDOW DISP >-w 0O 0< ›- C 0< 00 j c < (J) (2' MEN'S LIFEST LE AIR CARE Li CLUSTER TABLES I I j I II u / SHA'APOO F i U7 0 0 RETAIL 1100 LIGHTED WINDOW DISPLA' 4' EXPERIENCE TABLE(SEATING) EOL S1 S1-7 k75ccl V-5 o- S,V,V SHAMP CONDI T 0/ MAKEUP CHAIR TRAVEL TOWER SHAMPOO/ STYLE/ STYLE/ CONDITION FINISH FINISH i Y / \CHDRAIR/ER \ J MANICURE // ,/ // // // // TREE TMENt 103 S1-5 15cd V-3 L r 2C,S,V,V b C.{0.S.( ENTRY 102 S1-4 15cd SHOWER 105 I// i / PEDICUREAHU // // // // // // // // \ 2C,S,V,V' --o 2///i/ /, // /ice/r 4 S1-3 15cd V-2 TREATMENT 2 106 S1-2 \x, 2C,S,V,V 15cd RESTROOM ) 104 // // // LAUNDRY/BREAK 107 I 2C,S HAL 'OF S1-1 75cd V-1 D� TO NEAREST EXISTING DATA LOOP D6 Ea 0 E. P— UP 'BATH AND BODY WORKS' STORE FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER. AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 11OVAC BRANCH CIRCUIT. SMOKE DETECTOR MUST BE LOCATED IN THE SAME ROOM/AREA AS THE PAD -3. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. Proprietary and Confidential, Copyright 2010 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 3 0 DESCRIPTION SHOP DRAWINGS DATE 04/15/11 za<aaK 0 W Oza)) _IOJ� (/) Z (/) >. '�CWzz WCO CO 1-11‘_ (i) cCQ o g 0 W N W No > " W cc LT. SCALE; 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 04/ 15/ 1 1 BACKROUND PLAN PROVIDED BY: 1013 NUMBER: 55223 J SHEET FA -04