HomeMy WebLinkAboutPP - 251 SOUTHCENTER MALL - THAT KITCHEN SHOP - PERMITS AND PLANS251 SOUTHCENTER MALL ASSOCIATED PERMITS 15-F-168 12-S-118 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470130 Site Address: 251 Southcenter Mall, space 652, 98188 Suite Number: Floor: Tenant Name: Lol ll & Pops New Tenant? 0 - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: same as site address CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz City State Zip Day Telephone: 206„349.5889 Company Name: Guardian Security Systems Mailing Address: 1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City State Zip E-mail Address: Fax Number: 206.3742852 Total number of new/relocated devices or sprinkler heads: 8 Valuation of Project (contractor's bid price): $ 5,000. Scope of Work (please provide detailed information): Add 8 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Karina Veliz Plan Permit App.doc Day Telephone: 206.349.5889 1/2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 251 So11CQr -- mill I Suite Number:___ Floor: New Tenant? f:g- Yes ❑ - No Tenant Name: CAA \\ fe..• Property Owner's Name: Wec-Ae\ N%kxn 1e YI -{- (7.r oup Mailing Address: 1VOCA W \1 1\f-e..\Nic , kkh AY)Q,' eL , C/ CONTACT PERSON -if there are questions about the submittal. �j kea. Day Telephone: 1125.4 I :now Name: Company Name: nrovia \\y •Vf&\e h (3/'1, I vic. ��5�► CAO. Cr©uoYn Valuation of Project (contractor's bid price): $ (0(V) , CCI \Dr l Y1Qer City State Zip Mailing Address: E-mail Address: City •(c'yrr i Fax Number: Scope of Work (please provide detailed information): \mos PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CER111±Y THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 112_ Print Name: itS\C(1 f )bI lS Day Telephone: 'IZ ' 1481 7tD Plan Permit App.doc 5/14/10 TFD FP Form 3 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Culinaire 251 Southcenter Mall Permit No.: 12-S-118 Date: June 4, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. FIRE AL TU I RM SYSTEM ADDITION KWILA, '.`: ASHINGTON TIJKWILA FIRE id EPA RT t N Prsgs'". call 205-575-07 and give this Fire Permit No. and exact 2t.ldress for shut- down or r tc -Vicn approval. \--Without Comments LD As Noted in ReAl C7 Per The Attached Letter T heoe plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance wATfth current City . andards. Acceptan.:L_ is subject to errors and omissions which co noauthorize violations of adopted '',:,arziards and ordinances. The responsibility for the , deguacy of design rests totaiiy ?.with the designer. Additions, deletions or reViSI nS to these drawings after this date will void tnis :- ptance and will require a resubmittal of re.viseii drawings for suase.quent approve-% Final acceptance Is subject to fleici test and inspection by The Tukwila Fire Prevention Bureau. Date: 10 -*/(4, - I $ By: ! l SHEET \UM 3ER SHEET TITLE FA -01 SYSTEM INFO MATION FA -02 TYPICAL WIRING A\D VIOUNTI \G DETAILS FA -03 SYSTEM CALC U LATI O S A\D SINGLE LINE DIAGRAM FA -04 FI 'E ALARM SYSTEM PLAN SHEET INDEX WISE SCHE 3ULE A\D CO\DUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END 1 WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 9. 10 11 12 13 14 15 16 NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR S ZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN—UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN—UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17 ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23 NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI—CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX 1 1 2 4 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY FIRE ALARM STROBE ZR -MC -CW SIEMENS SIEMENS 4S BOX PAQ 4S BOX VERIFY IN FIELD Di FIRE ALARM SPEAKER STROBE ZH-MC-CW SIEMENS 4S BOX CEILING END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NOTICE 4 completed, signed, Tukwila LOLLI AND POPS #251 / SPACE #652 Fire Department Pre-test Certificate must be presented to the Inspector prior to commencer, ;t Of Acceptance Testing of any Fire Alarm and Detection Systerns. Failure of test will result in a Re -inspection Fee and termination of the testing NORDSTROM 3 L EVELS 171,275s, —lrmrrr TuA SHOP GNE JsT *Tar'L E .0,1v1KAP 'N -DER pc) ;❑ {� I 6' a aPP-CAST 0-1&: - I I--; TIRE V. i OUCO 'f.FIZON '&?£LESS PE P`,11..£ PEv . YA2 IH *ASie1CTCli APEEPCPOU Z • x_s QASR4 v , Pic pP:pi CC -T EP.Hx4 u41:R' CPGCC P1111. CC -5T' E;a?APY ,REO YE _ R 1 £AEEERS � 2•1 €snnc JCPenney 3 L�LiS 3 LEVELS 27 ,468ef PAJ"C SFA I• R PLAYTOM SEARS YOCIOMPOS RESTAI4A O& 1PE0RA4N I'• PESTUCLM PARD SITE PLAN AT D PAID OCT -- -5.2015 TUKW FIR Ccv- 075 a` 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE 0 0 0 1 z coo (j) O o "z (1) Q_O CL Q O p w _ Q wQ J goS w E_-- 1 LL O F T ) 0 CC 0 u•>•1 N N "CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/06/15 BACKROUND PLAN PROVIDED BY: Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ..JOB NUMBER:13560-1} U SHEET n FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. PUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ DEDICATED EMERGENCY TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE: FOR ADDIRONAL SPEC:MAIMS SFE PRODUCT DOp*TATION. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC Efficl MN re TD NEXT ADDRESSABLE(+ DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL (1 DR PREVIWS ADDRESSABLE DEVICE 0 0 F-61 a ' I aJ HTRI-R GROUND -1L 0 0 O o 0 NOTE: FOR ADDITIONAL SPEaF1CA1ONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE X00 11 0 PAD -3 ooKl) INPUT INPUT TROUBLE NAC' NAC2 NAC3 NAC4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - -444 m .a 3.6k EOL (-) (+) NAC4CIRCUIT j NAC 3 CIRCUIT NAC 2 CIRCUIT CEILIN TILE 0° SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /- HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (-) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL DR PREVIOUS ADDRESSABLE DEVIC 0 (+) A 0 END OF LINE DEVICE(3,6K 1/4W) 1 ,ma e) SUPERVISED SWITCH GROUND ---10 LC) HTRI-R OSTATUS LED m N.0 t\ m COM 0 N.0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 • HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY + HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL MUSIC 1/{C POWER SOURCE COMBINE AL SHIELDS AND ISOLATE FR M GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4,OA 2 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERATURE: +32' F (0' C TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —A. -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > TO NEXT DEVICE OR END OF LINE DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB-11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL > TO NEXT ADDRESSABLE DEVICE TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE TB1 NO COM NC EOLR 470 0 0 SWITCH + — INPUT LED TSM -1 00 00 TO FAN SHUTDOWN TO NEXT ADDRESSABLE DEVICE 0 00 HTRI-R NO B COM NC ® 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT j 0 0 O OTO NEXT DEVICE CADDY BAR J SMOKE DETECTOR \\- SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Pro • rieta and Confidential, Co. ri. ht 2013 b Guardian Securit S stems, Inc. All R. • hts Reserved RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE Ln (0 0 0 es c0 z co U) ooh CL < o p z 0 �E 0L w Q z <00< WQ O WQ� CC Do co T N SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/06/15 BACKROUND PLAN PROVIDED BY: �OB NUMBER:13560-12 SHEET FA -02 A B C D E F G H I J K FIRE ALARM BOOSTER Project: LOLLI AND POPS Panel: EXISTING BPS PAD -3 Date: October 6, 2015 Module/Device POWER BOOSTER Qty SUPPLY POWER Standby (mA) BATTERY CALCULATION Alarm (mA) Total Alarm (mA) SUPPLY Total Standby (mA) Power Module 1 30 30 0 30 30 0 TOTAL FIRE ALARM POWER SUPPLY 30' 30 Auxiliary Device Current 0 0 Notification Appliance Load (Max Total / mA) 0 2024 Total(A)= : CALCULATION 30 Total(B)= 2054 Qty Total current ratings of all devices in system (line A + line B + line C) 30 2054 Total current ratings converted to amperes (line D x .001) 0.03 2.054 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 0.0022 Multiply lines E and F Total Standby AH 0.72 Alarm sounding period in hours (5 mins+ .0833 hours) 1 0.0833 Multiply lines E and H Total Alarm AH 0.064 0.1710982 Add lines G and I Total Standby and Alarm AH 0.8910982 2 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 1.06931784 0.021 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP • • Notification A n it Appliance ce C cuit Detail PROJECT: LOLLI AND POPS Panel: EXISTING PAD -3 POWER SUPPLY Date: October 6, 2015 Wire Resistance 2.58 CURRENT TOTAL='2024.00 ZH-MC-CWA15cd j 87 ZH-MC-CW 'A30cd 131 ZH-MC-CW A75cd 222; ZH-MC-CW @95cd 292 • ZR -MC -CW A15cd i 69: ZR -MC -CW @30cd 111 DEVICES 4 TOTAL mA= Total Wire Resistance (R) Total Device Load, Amps (1) -_ Voltage Drop (E ) EOL Voltage 0 524; 14 289 23.22 524 (WL*2)*(Rlft) - 1.49 (Total Cct Loads 0.52 (E 1 * R) 0.78 23.22 ZH-MC-CW A15cd Ai -MC -CW -74300 ZH-MC-CW A75cd 2221 ZH-MC-C111t 95cd • 292 ZR -MC -CW A15cd 691 ZR-11ltC-C1tV�@3Ocd a 111 DEVICES 0� TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1 Voltage Drop ( E ) N _ L Voltage 1500j 14 24.00; 1500 (WL*2)*(R/ft) j 0.00 (Total Cct Load) 1,50 (E= I * R) 0.00 24 - E) 24.00 • CALCULATIONS r Y fi 1 1k F I �.^Y � rn M �. h td' i I ¢^ d t Wµ� h N ri 'a �. � , pat ..�" x , r`� , x, ry ,#t' ,W� f .4.,I,` �; ��� ,i @ u � °'�:,,� �1 SIF J.'',.'"d, w, y� 1,'�,.1,� `' ? � @ 4 Y ! �Fk T T�`, 1 I„Yn��F,� i. , . I A S r3 id T q DESCRIPTION SHOP DRAWINGS Current Load: Lu Q C) Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 1 0,0022 0.0022 0.0023 0.002 FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps (EXISTING BACK -OF - S1 -1 S1-2 S1-3 S1-4 THE -HOUSE J -BOX) 30cd 30cd 30cd 30cd D,I • 21 I TSM SINGLE LINE DIAGRAM EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS Lu Q C) Ln o \ 0 0 0 w z N In zooco W coQ 0 z) -3 - EO) C� O oZ z w<z 0 o Z cc(T) 2z> .1ccwoO o W� o T V N .I w >- (1) CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:10/06/ 15 BACKROUND PLAN PROVIDED BY: \ 0B NUMBER:13560-1j 1 SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved TO EXISTING BACK -OF -THE HOUSE JUNCTION BOX r D -cp s 6Th • 1 I 1 I, • I ': : I ' I : r---; ! M.--II0 • : • i • - , , • - ‘11k17Acri-- (,)1 i 1 '.• ! • : ;;; I I • I- 0 E I 1 E . I : ; 1 I 24'-o" 1 ;•I1•, ! !si ! !! ; S1-1 30cd HT -RI D 6 LI-- _ . ,. . . 11. - -1 I I III 4 S1-2 1„\ 1Ir\r`()1 r r_„Thr. 30cd I IN. • __________ • _ _ [L— I I ! 1 111 _ 0 ! . , , I f E ; / ! I I _I ! 1 I • II! ! ! I , ) F-2 ___ • —G F12 1/j I r hr'J E 1 S1-3 s‘ 30cd Flys Ti p , . CHFDUL 1 F-1 F-2 I MANAGERS DESK & WALL SHELF 7 I 49" WIDE FIXTURE WITH SHELVES AND LOWER DOORS I F-3 I 24" WIDE FIXTURE WITH WOOD SHELVE F-4 POINT GF SALE (POS) COUNTER F-5 6 I END COLUMN WITH GLASS SHELVES 1 F-6 1 1 WORK / SERVICE COUNTER ‘`,PITH • CAB -NETS F-7 1 1 LOLLI POP WALL I F-8 1 I 3 -BN FIXTURE F-9 21 1 L -BIN FIXTURE Is -1 0 4 1 5-B1N FIXTURE 1 F-11 F-12 F-13 F-14 F-15 1 GUMMI BASE WITH BINS - 58" WIDE 7 1 CONSOLE TABLE - 36" X 58" 1 CONSOLE TABLE - 30" X 30" 2 1 BASE CABINET UNDER FRONT WINDOW 3 1 CONSOLE TABLE - 36" ROUND I F-16 BASE CABINET WITH IMPULSE SHELF I I E-26 I , 1 F2 i I I I I I ! • I I EOL S1 -N\ I • 1 r^: •,1 1/ • Lr_‘!". 1-/ S1-4 .• 30cd ..• _ A . , „ . .•• ..• , I . ! , 1 g. 1— , ..,!. . . , . . . , .•:. ,- . . . . ,.. . . 1 ! , • 1 . .• . . . ..• . \ - r IF:F:1 [ 's- ,._ !----- •,,,, „, , ... , ! ,, s. t, , , . I i 1----',71: , ,...1 .. \-• . / .. " .• . .. .‘-',.. II I I i E ..._____41 'IEE{II I_ T C...!'•,!!'"..s EQUI t \ I sr is-iTh1 u Is' NI • , 1 0 M 0 I SHOP DRAWINGS I E - 1 2 TRUFFLE DISPLAY CASE ALTERNATIVE AIR MCCA-96-R SELF CONTAINED UNIT; FURNISHED BY LP AND INSTALLED BY FC 1 E-2 2 BEVERAGE CENTER (1.7 CU.s1.) KENMORE 99283 FURNISHED AND INSTALLED BY LP I E-3 2 SODA COOLER TURBO AIR TOM -50B SELF CONTAINED UNIT; FURNISHED BY LP AND INSTALLED BY FC I [-4 1 HAND SINK SEE PLUMBING SHT. <<<<< TGC TC PROVIDE CLEAR ACRYLIC SPLASH GUARD WITH SMALL BLACK SCREWS. I E-5 1 FAUCET SEE PLUMBING SHT. - SPLASH GUARD SHALL BE 12" TALL x WIDTH OF SINK +6". 1 E-6 1 PAPER TOWEL HOLDER ULINE (OR EQU.AL) H2269 TGC TC FURNISH AND INSTALL ON INSIDE FACE OF CABINET DOOR E-7 1 BUZZER SEE ELECTRICAL SHT. - I E-8 2 DOOR BELL SEE ELECTRICAL SHT. - 1 E-9 1 MOP SINK AND FAUCET SEE PLUMBING SHT. - E-10 1 MOP / BROOM HOLDER ULINE (OR EQUAL) H2840 - • E-11 1 3 COMPARTMENT SINK AND FAUCET SEE PLUMBNG SHT. MAX VINYL BIN SIZE IS 8" WIDE x 12" DEEP x 12" TALL 1 E-12 1 FLOOR SINK SEE PLUMBING SHT. - I E-13 1 WELL ORGANIZER SHELVES AMCO 11NAC1248CP 2 -SHELF DRYING RACK I E-14 1 MANUAL SOAP DISPBSER [CO LAB SYSTEMS NEXA - 1 15 1 PAPER TOWEL DISPENSER ULINE (OR EQUAL) H2275 i E- 16 1 HAND SINK SEE PLUMBING SHT. - - E- 17 1 WATER HEATER SEE PLUMBING SHT. - F-18 1 UPRIGHT FREEZER (16.6 CU.FT.) KENMORE 22742 FURNISHED AND INSTALLED BY L&P 1 E-19 1 MEDIA CABINET VIDEO MOUNT PROD. ERWEN - 12E SEE ELECTRICAL SHT. 1 E-20 1 LOCKER (6 -TIER) !LINE (OR EQUAL) H-1845 TGC TO BOLT TO FLOOR I E - 21 1 WALL MOUNTED COAT RACK - PROVIDE 48" WIDE HANGING BAR AND SHELF SIM TO ULINE H2515 1 E-22 5 STORAGE RACK METRO 2448NK3 SUPER ERECTA SHELF, FURNISHED AND INSTALLED BY LP 1 [-23 1 FLOOR SAFE SENTRY FIRE SAFE FURNISHED BY LP, TGC TO BOLT TO FLOOR 1 E-24 1 TIMECLOCK SEE ELECTRICAL SHT. - - E-25 1 STOREFRONT GRILLE METRO DOOR V36 LEXAN FURNISHED AND INSTALLED BY LP / LP VENDOR, TGC TO COORDINATE WITH FRAMING. E-26 2 FIRE EXTINGUISHER - PROVIDE WALL MOUNTED EXTINGUISHER AT STORAGE ROOM, PROVIDE EXTINGUISHER AT POS. FIRE ALARM SYSTEM PLAN !!' . -------- I — E— E _.1 A Dr FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. rr) CO 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE Ln CD 0 0 ,.._, <<<<< 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/06/15 BACKROUND PLAN PROVIDED BY: ..JOB NUMBER:13560-11 I- SHEET FA -04 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 0 Wthout Comments As 1\-!ureci ; Red lilra F : ' Letter Peri���e At�ac:� ��: Ip(,lloannsha'e yE -re''e°,edLThe T ukwila Fire Bure:.A, .;[.r: a•cr current City • .-,dards. Accc'-.:?.;::: ^ <.c: to erros and 3!ons which e —. r :J: vio ti jns of adopted :ndards and The r€:3p -4 s.ibttiuy for the ,quacy of de rr. , 'Plitt") (r:? designer. i=tons, f1& to - •: `i?; !" : ii C se runt ings after • _ elate. will vokci ce.cLiire a •.submittal of r :� _ :�,:r. approval ial acceptance i, sr r:::j`: is '!.'!.1 and inspection h' :e Tukwila Fire .Prevenl.rn RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TQP BEAM/ C -CLAMP WITH SET SCBE W 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS . HANGER DETAIL NTS Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinlder heads to remain unobstructed by lightings, ceilings, or an other All heads to be at least 6' apart Y means 3 — Relocate Reliable Model G4A Standard Response Concealed 165° Pendents 1/2 x 1/2 o E — Existing pendent no change 3 — Total REFLECTED CEILING PLAN 1/8" = 11-0" TUKWIL`, FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address for shut- down hutdown or restoration approval. CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Culinaire 251 Southcenter Mall Space 652 Tukwila, WA 98188 PAID MANY 31 2012 TUK HILA FIRE ,/-7.27e) DATE: 5. 2.41.1Z DRAWN: 65— SCALE: 251 SOUTHCENTER MALL ASSOCIATED PERMITS 15-F-168 12-S-118 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470130 Site Address: 251 Southcenter Mall, space 652, 98188 Suite Number: Floor: Tenant Name: Lol ll & Pops New Tenant? 0 - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: same as site address CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz City State Zip Day Telephone: 206„349.5889 Company Name: Guardian Security Systems Mailing Address: 1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City State Zip E-mail Address: Fax Number: 206.3742852 Total number of new/relocated devices or sprinkler heads: 8 Valuation of Project (contractor's bid price): $ 5,000. Scope of Work (please provide detailed information): Add 8 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Karina Veliz Plan Permit App.doc Day Telephone: 206.349.5889 1/2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 251 So11CQr -- mill I Suite Number:___ Floor: New Tenant? f:g- Yes ❑ - No Tenant Name: CAA \\ fe..• Property Owner's Name: Wec-Ae\ N%kxn 1e YI -{- (7.r oup Mailing Address: 1VOCA W \1 1\f-e..\Nic , kkh AY)Q,' eL , C/ CONTACT PERSON -if there are questions about the submittal. �j kea. Day Telephone: 1125.4 I :now Name: Company Name: nrovia \\y •Vf&\e h (3/'1, I vic. ��5�► CAO. Cr©uoYn Valuation of Project (contractor's bid price): $ (0(V) , CCI \Dr l Y1Qer City State Zip Mailing Address: E-mail Address: City •(c'yrr i Fax Number: Scope of Work (please provide detailed information): \mos PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CER111±Y THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 112_ Print Name: itS\C(1 f )bI lS Day Telephone: 'IZ ' 1481 7tD Plan Permit App.doc 5/14/10 TFD FP Form 3 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Culinaire 251 Southcenter Mall Permit No.: 12-S-118 Date: June 4, 2012 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. FIRE AL TU I RM SYSTEM ADDITION KWILA, '.`: ASHINGTON TIJKWILA FIRE id EPA RT t N Prsgs'". call 205-575-07 and give this Fire Permit No. and exact 2t.ldress for shut- down or r tc -Vicn approval. \--Without Comments LD As Noted in ReAl C7 Per The Attached Letter T heoe plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance wATfth current City . andards. Acceptan.:L_ is subject to errors and omissions which co noauthorize violations of adopted '',:,arziards and ordinances. The responsibility for the , deguacy of design rests totaiiy ?.with the designer. Additions, deletions or reViSI nS to these drawings after this date will void tnis :- ptance and will require a resubmittal of re.viseii drawings for suase.quent approve-% Final acceptance Is subject to fleici test and inspection by The Tukwila Fire Prevention Bureau. Date: 10 -*/(4, - I $ By: ! l SHEET \UM 3ER SHEET TITLE FA -01 SYSTEM INFO MATION FA -02 TYPICAL WIRING A\D VIOUNTI \G DETAILS FA -03 SYSTEM CALC U LATI O S A\D SINGLE LINE DIAGRAM FA -04 FI 'E ALARM SYSTEM PLAN SHEET INDEX WISE SCHE 3ULE A\D CO\DUIT FILL CHAT WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END 1 WIRE DESIGNATION FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 9. 10 11 12 13 14 15 16 NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR S ZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN—UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN—UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17 ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23 NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI—CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED GENERAL NOTES QUANTITY EX 1 1 2 4 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP DUCT DETECTOR FDBZ492-HR W/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD HT -R INTERFACE MODULE HTRI-R WITH RELAY FIRE ALARM STROBE ZR -MC -CW SIEMENS SIEMENS 4S BOX PAQ 4S BOX VERIFY IN FIELD Di FIRE ALARM SPEAKER STROBE ZH-MC-CW SIEMENS 4S BOX CEILING END -OF -LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NOTICE 4 completed, signed, Tukwila LOLLI AND POPS #251 / SPACE #652 Fire Department Pre-test Certificate must be presented to the Inspector prior to commencer, ;t Of Acceptance Testing of any Fire Alarm and Detection Systerns. Failure of test will result in a Re -inspection Fee and termination of the testing NORDSTROM 3 L EVELS 171,275s, —lrmrrr TuA SHOP GNE JsT *Tar'L E .0,1v1KAP 'N -DER pc) ;❑ {� I 6' a aPP-CAST 0-1&: - I I--; TIRE V. i OUCO 'f.FIZON '&?£LESS PE P`,11..£ PEv . YA2 IH *ASie1CTCli APEEPCPOU Z • x_s QASR4 v , Pic pP:pi CC -T EP.Hx4 u41:R' CPGCC P1111. CC -5T' E;a?APY ,REO YE _ R 1 £AEEERS � 2•1 €snnc JCPenney 3 L�LiS 3 LEVELS 27 ,468ef PAJ"C SFA I• R PLAYTOM SEARS YOCIOMPOS RESTAI4A O& 1PE0RA4N I'• PESTUCLM PARD SITE PLAN AT D PAID OCT -- -5.2015 TUKW FIR Ccv- 075 a` 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: DMG I DESCRIPTION SHOP DRAWINGS DATE 0 0 0 1 z coo (j) O o "z (1) Q_O CL Q O p w _ Q wQ J goS w E_-- 1 LL O F T ) 0 CC 0 u•>•1 N N "CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/06/15 BACKROUND PLAN PROVIDED BY: Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved ..JOB NUMBER:13560-1} U SHEET n FA -01 THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. PUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ DEDICATED EMERGENCY TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE: FOR ADDIRONAL SPEC:MAIMS SFE PRODUCT DOp*TATION. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC Efficl MN re TD NEXT ADDRESSABLE(+ DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL (1 DR PREVIWS ADDRESSABLE DEVICE 0 0 F-61 a ' I aJ HTRI-R GROUND -1L 0 0 O o 0 NOTE: FOR ADDITIONAL SPEaF1CA1ONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE X00 11 0 PAD -3 ooKl) INPUT INPUT TROUBLE NAC' NAC2 NAC3 NAC4 AUX +1- 1 2+2- 2 NC C NO + - + - + - + - + - -444 m .a 3.6k EOL (-) (+) NAC4CIRCUIT j NAC 3 CIRCUIT NAC 2 CIRCUIT CEILIN TILE 0° SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING /- HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL (-) EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL DR PREVIOUS ADDRESSABLE DEVIC 0 (+) A 0 END OF LINE DEVICE(3,6K 1/4W) 1 ,ma e) SUPERVISED SWITCH GROUND ---10 LC) HTRI-R OSTATUS LED m N.0 t\ m COM 0 N.0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 • HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY + HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL MUSIC 1/{C POWER SOURCE COMBINE AL SHIELDS AND ISOLATE FR M GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4,OA 2 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERATURE: +32' F (0' C TO 100' F (38' C) HUMIDITY: 0-9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —A. -� FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( )> DATA IN (+) > TO NEXT DEVICE OR END OF LINE DEVICE IS USTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR DB-11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL > TO NEXT ADDRESSABLE DEVICE TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE TB1 NO COM NC EOLR 470 0 0 SWITCH + — INPUT LED TSM -1 00 00 TO FAN SHUTDOWN TO NEXT ADDRESSABLE DEVICE 0 00 HTRI-R NO B COM NC ® 0 TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT j 0 0 O OTO NEXT DEVICE CADDY BAR J SMOKE DETECTOR \\- SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Pro • rieta and Confidential, Co. ri. ht 2013 b Guardian Securit S stems, Inc. All R. • hts Reserved RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE Ln (0 0 0 es c0 z co U) ooh CL < o p z 0 �E 0L w Q z <00< WQ O WQ� CC Do co T N SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/06/15 BACKROUND PLAN PROVIDED BY: �OB NUMBER:13560-12 SHEET FA -02 A B C D E F G H I J K FIRE ALARM BOOSTER Project: LOLLI AND POPS Panel: EXISTING BPS PAD -3 Date: October 6, 2015 Module/Device POWER BOOSTER Qty SUPPLY POWER Standby (mA) BATTERY CALCULATION Alarm (mA) Total Alarm (mA) SUPPLY Total Standby (mA) Power Module 1 30 30 0 30 30 0 TOTAL FIRE ALARM POWER SUPPLY 30' 30 Auxiliary Device Current 0 0 Notification Appliance Load (Max Total / mA) 0 2024 Total(A)= : CALCULATION 30 Total(B)= 2054 Qty Total current ratings of all devices in system (line A + line B + line C) 30 2054 Total current ratings converted to amperes (line D x .001) 0.03 2.054 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 0.0022 Multiply lines E and F Total Standby AH 0.72 Alarm sounding period in hours (5 mins+ .0833 hours) 1 0.0833 Multiply lines E and H Total Alarm AH 0.064 0.1710982 Add lines G and I Total Standby and Alarm AH 0.8910982 2 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 1.06931784 0.021 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 TO NEAREST EXISTING POWER SUPPLY TO NEAREST EXISTING DATA LOOP • • Notification A n it Appliance ce C cuit Detail PROJECT: LOLLI AND POPS Panel: EXISTING PAD -3 POWER SUPPLY Date: October 6, 2015 Wire Resistance 2.58 CURRENT TOTAL='2024.00 ZH-MC-CWA15cd j 87 ZH-MC-CW 'A30cd 131 ZH-MC-CW A75cd 222; ZH-MC-CW @95cd 292 • ZR -MC -CW A15cd i 69: ZR -MC -CW @30cd 111 DEVICES 4 TOTAL mA= Total Wire Resistance (R) Total Device Load, Amps (1) -_ Voltage Drop (E ) EOL Voltage 0 524; 14 289 23.22 524 (WL*2)*(Rlft) - 1.49 (Total Cct Loads 0.52 (E 1 * R) 0.78 23.22 ZH-MC-CW A15cd Ai -MC -CW -74300 ZH-MC-CW A75cd 2221 ZH-MC-C111t 95cd • 292 ZR -MC -CW A15cd 691 ZR-11ltC-C1tV�@3Ocd a 111 DEVICES 0� TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1 Voltage Drop ( E ) N _ L Voltage 1500j 14 24.00; 1500 (WL*2)*(R/ft) j 0.00 (Total Cct Load) 1,50 (E= I * R) 0.00 24 - E) 24.00 • CALCULATIONS r Y fi 1 1k F I �.^Y � rn M �. h td' i I ¢^ d t Wµ� h N ri 'a �. � , pat ..�" x , r`� , x, ry ,#t' ,W� f .4.,I,` �; ��� ,i @ u � °'�:,,� �1 SIF J.'',.'"d, w, y� 1,'�,.1,� `' ? � @ 4 Y ! �Fk T T�`, 1 I„Yn��F,� i. , . I A S r3 id T q DESCRIPTION SHOP DRAWINGS Current Load: Lu Q C) Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 1 0,0022 0.0022 0.0023 0.002 FDBZ492-HR 1 0.0635 0.0635 0.064 0.064 HTRI MODULE 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps (EXISTING BACK -OF - S1 -1 S1-2 S1-3 S1-4 THE -HOUSE J -BOX) 30cd 30cd 30cd 30cd D,I • 21 I TSM SINGLE LINE DIAGRAM EOL S1 FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS Lu Q C) Ln o \ 0 0 0 w z N In zooco W coQ 0 z) -3 - EO) C� O oZ z w<z 0 o Z cc(T) 2z> .1ccwoO o W� o T V N .I w >- (1) CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:10/06/ 15 BACKROUND PLAN PROVIDED BY: \ 0B NUMBER:13560-1j 1 SHEET FA -03 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved TO EXISTING BACK -OF -THE HOUSE JUNCTION BOX r D -cp s 6Th • 1 I 1 I, • I ': : I ' I : r---; ! M.--II0 • : • i • - , , • - ‘11k17Acri-- (,)1 i 1 '.• ! • : ;;; I I • I- 0 E I 1 E . I : ; 1 I 24'-o" 1 ;•I1•, ! !si ! !! ; S1-1 30cd HT -RI D 6 LI-- _ . ,. . . 11. - -1 I I III 4 S1-2 1„\ 1Ir\r`()1 r r_„Thr. 30cd I IN. • __________ • _ _ [L— I I ! 1 111 _ 0 ! . , , I f E ; / ! I I _I ! 1 I • II! ! ! I , ) F-2 ___ • —G F12 1/j I r hr'J E 1 S1-3 s‘ 30cd Flys Ti p , . CHFDUL 1 F-1 F-2 I MANAGERS DESK & WALL SHELF 7 I 49" WIDE FIXTURE WITH SHELVES AND LOWER DOORS I F-3 I 24" WIDE FIXTURE WITH WOOD SHELVE F-4 POINT GF SALE (POS) COUNTER F-5 6 I END COLUMN WITH GLASS SHELVES 1 F-6 1 1 WORK / SERVICE COUNTER ‘`,PITH • CAB -NETS F-7 1 1 LOLLI POP WALL I F-8 1 I 3 -BN FIXTURE F-9 21 1 L -BIN FIXTURE Is -1 0 4 1 5-B1N FIXTURE 1 F-11 F-12 F-13 F-14 F-15 1 GUMMI BASE WITH BINS - 58" WIDE 7 1 CONSOLE TABLE - 36" X 58" 1 CONSOLE TABLE - 30" X 30" 2 1 BASE CABINET UNDER FRONT WINDOW 3 1 CONSOLE TABLE - 36" ROUND I F-16 BASE CABINET WITH IMPULSE SHELF I I E-26 I , 1 F2 i I I I I I ! • I I EOL S1 -N\ I • 1 r^: •,1 1/ • Lr_‘!". 1-/ S1-4 .• 30cd ..• _ A . , „ . .•• ..• , I . ! , 1 g. 1— , ..,!. . . , . . . , .•:. ,- . . . . ,.. . . 1 ! , • 1 . .• . . . ..• . \ - r IF:F:1 [ 's- ,._ !----- •,,,, „, , ... , ! ,, s. t, , , . I i 1----',71: , ,...1 .. \-• . / .. " .• . .. .‘-',.. II I I i E ..._____41 'IEE{II I_ T C...!'•,!!'"..s EQUI t \ I sr is-iTh1 u Is' NI • , 1 0 M 0 I SHOP DRAWINGS I E - 1 2 TRUFFLE DISPLAY CASE ALTERNATIVE AIR MCCA-96-R SELF CONTAINED UNIT; FURNISHED BY LP AND INSTALLED BY FC 1 E-2 2 BEVERAGE CENTER (1.7 CU.s1.) KENMORE 99283 FURNISHED AND INSTALLED BY LP I E-3 2 SODA COOLER TURBO AIR TOM -50B SELF CONTAINED UNIT; FURNISHED BY LP AND INSTALLED BY FC I [-4 1 HAND SINK SEE PLUMBING SHT. <<<<< TGC TC PROVIDE CLEAR ACRYLIC SPLASH GUARD WITH SMALL BLACK SCREWS. I E-5 1 FAUCET SEE PLUMBING SHT. - SPLASH GUARD SHALL BE 12" TALL x WIDTH OF SINK +6". 1 E-6 1 PAPER TOWEL HOLDER ULINE (OR EQU.AL) H2269 TGC TC FURNISH AND INSTALL ON INSIDE FACE OF CABINET DOOR E-7 1 BUZZER SEE ELECTRICAL SHT. - I E-8 2 DOOR BELL SEE ELECTRICAL SHT. - 1 E-9 1 MOP SINK AND FAUCET SEE PLUMBING SHT. - E-10 1 MOP / BROOM HOLDER ULINE (OR EQUAL) H2840 - • E-11 1 3 COMPARTMENT SINK AND FAUCET SEE PLUMBNG SHT. MAX VINYL BIN SIZE IS 8" WIDE x 12" DEEP x 12" TALL 1 E-12 1 FLOOR SINK SEE PLUMBING SHT. - I E-13 1 WELL ORGANIZER SHELVES AMCO 11NAC1248CP 2 -SHELF DRYING RACK I E-14 1 MANUAL SOAP DISPBSER [CO LAB SYSTEMS NEXA - 1 15 1 PAPER TOWEL DISPENSER ULINE (OR EQUAL) H2275 i E- 16 1 HAND SINK SEE PLUMBING SHT. - - E- 17 1 WATER HEATER SEE PLUMBING SHT. - F-18 1 UPRIGHT FREEZER (16.6 CU.FT.) KENMORE 22742 FURNISHED AND INSTALLED BY L&P 1 E-19 1 MEDIA CABINET VIDEO MOUNT PROD. ERWEN - 12E SEE ELECTRICAL SHT. 1 E-20 1 LOCKER (6 -TIER) !LINE (OR EQUAL) H-1845 TGC TO BOLT TO FLOOR I E - 21 1 WALL MOUNTED COAT RACK - PROVIDE 48" WIDE HANGING BAR AND SHELF SIM TO ULINE H2515 1 E-22 5 STORAGE RACK METRO 2448NK3 SUPER ERECTA SHELF, FURNISHED AND INSTALLED BY LP 1 [-23 1 FLOOR SAFE SENTRY FIRE SAFE FURNISHED BY LP, TGC TO BOLT TO FLOOR 1 E-24 1 TIMECLOCK SEE ELECTRICAL SHT. - - E-25 1 STOREFRONT GRILLE METRO DOOR V36 LEXAN FURNISHED AND INSTALLED BY LP / LP VENDOR, TGC TO COORDINATE WITH FRAMING. E-26 2 FIRE EXTINGUISHER - PROVIDE WALL MOUNTED EXTINGUISHER AT STORAGE ROOM, PROVIDE EXTINGUISHER AT POS. FIRE ALARM SYSTEM PLAN !!' . -------- I — E— E _.1 A Dr FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. rr) CO 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE Ln CD 0 0 ,.._, <<<<< 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 10/06/15 BACKROUND PLAN PROVIDED BY: ..JOB NUMBER:13560-11 I- SHEET FA -04 Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 0 Wthout Comments As 1\-!ureci ; Red lilra F : ' Letter Peri���e At�ac:� ��: Ip(,lloannsha'e yE -re''e°,edLThe T ukwila Fire Bure:.A, .;[.r: a•cr current City • .-,dards. Accc'-.:?.;::: ^ <.c: to erros and 3!ons which e —. r :J: vio ti jns of adopted :ndards and The r€:3p -4 s.ibttiuy for the ,quacy of de rr. , 'Plitt") (r:? designer. i=tons, f1& to - •: `i?; !" : ii C se runt ings after • _ elate. will vokci ce.cLiire a •.submittal of r :� _ :�,:r. approval ial acceptance i, sr r:::j`: is '!.'!.1 and inspection h' :e Tukwila Fire .Prevenl.rn RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TQP BEAM/ C -CLAMP WITH SET SCBE W 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS . HANGER DETAIL NTS Design per NFPA 13, Ordinary Hazard, Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinlder heads to remain unobstructed by lightings, ceilings, or an other All heads to be at least 6' apart Y means 3 — Relocate Reliable Model G4A Standard Response Concealed 165° Pendents 1/2 x 1/2 o E — Existing pendent no change 3 — Total REFLECTED CEILING PLAN 1/8" = 11-0" TUKWIL`, FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address for shut- down hutdown or restoration approval. CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Culinaire 251 Southcenter Mall Space 652 Tukwila, WA 98188 PAID MANY 31 2012 TUK HILA FIRE ,/-7.27e) DATE: 5. 2.41.1Z DRAWN: 65— SCALE: