HomeMy WebLinkAboutPP - 281 SOUTHCENTER MALL - TALLS CAMERAS - PERMITS AND PLANSr 281 SOUTHCENTER MALL ASSOCIATED PERMITS 14-F-035 14-S-040 14-S-037 1 22g - OttiLlr4I SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address: 281 Southcenter Mall Tukwila, WA 98188 Suite Number: Floor: Tenant Name: Tal l's Camera New Tenant? - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 E-mail Address: kveliz@guardiansecurity.com Total number of new/relocated devices or sprinkler heads: 8 Valuation of Project (contractor's bid price): $ 2000 City State Zip Fax Number: 206.628.4990 Scope of Work (please provide detailed information): Adding 8 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NE t OR AUTHORIZ s 1 AGENT: Signature: • _ Date: ` ` 1 Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 01144 44tt SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 255\ Cb � l (" n lC�� 1 Y7'7ck\) Suite Number: � Floor: Tenant Name: ----Va\\S C Y Y \ r (1 New Tenant? K.- Yes ❑ - No Property Owner's Name: \oe c, - -\-ENA. �j- Mailing Address: CONTACT PERSON -if there are questions about the submittal. Name: Company Name: `CCS. i�1Yl� f) City State Zip Day Telephone: Z l / 7CC)f(�9 Mailing Address: VO X \2.\\J V f l 1` c�'e--e\c, \o/ O L E-mail Address: Total number of new/relocated devices or sprinkler heads: 1 Stater of Ci Fax Number: 6l2 c '� �f \l1 1 recuac Valuation of Project (contractor's bid price): $ \ �` Cs( cC , �P\ecce,C 144)) Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: n I Signature: -,��� / to ��� Date: 2:2-60 ' J Print Name: *SJ RCa , Q77 Plan Permit App.doc Day Telephone: O 1. 7M0 (o9 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Tall's Camera 281 Southcenter Ma;; Permit No.: 14-S-040 Date: March 3, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. 02/27/2014 15:55 4254818695 FAX TRA N SJ\ I I TTAL CROWN FIRE FILE Fax No. CROWN FIRE PROTECTION, INC. 2.27.14 Fire Prevention Bureau Tukwila Fire Department / Al Demo Permit ( ItIl3�}�I11� Number 01 1'a!2 -.t.• (Inciudinfl ( fid cr) PAGE 01101 1206.575.4439 1 • CERTITE � CATS OFC OMPET&NRY FIRE PROTECTION SPRINKLER S''a 1 f John J. Abet 19700-0 1 -CG Level r P►OteCtiOn„ inC CR ■ r ✓ 0 Urgent 21For Review 0 Please Comment 0 Please Reply Cristie Ogland Comments PH:425.481.7669 FX:425.481.8695 Please provide a demo permit to remove (4) sprinkler heads that are in the way of the framing at the Tall's Camera project at 281 Southcenter Mall. The building permit tf is D13-0379. Please lei us know if you have any questions. That s-- TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. 14-5-a3-! and exact address for shut- down or restoration approval. P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8695 r ACCEPTED o Without Comments o As Noted in Red ,Er Per The Attached Letter These pians have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City tandards. Acceptance is subject to errors and omissions which do not authorize violations of adopted ;' andards and ordinances. The responsibility for the dequacy of design rests totally with the designer. dditions, deletions or revisions to these drawings after rlrls date will void this acceptance and will require a .-e3ubmittal of revised drawings for subsequent approval. 1=anal acceptance is subject to-fleld test and inspection by me Tukwila Fire Prevention Bureau. Date: 3 - - % `' 6y: SII TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. / L,/ . o&I0 and exact address for shut- down hutdown or restoration approval. EXISTING (3\J e, CEILING 14 0 I-- LINE OF EXISTING MALL FASCIA ABOVE EXISTING CEILING EXISTING ACT CEILING, PAINT TO MATCH EXISTING REFLECTED CEILING PLAN at HIGH CEILING SCALE: 1/4"=r--0" EXISTING 2'x2' ACT CEILING TILE WITH TEGULAR EDGE/REVEAL 'ARMSTRONG' FINE FISSURED SECOND LOOK, 6"x6" SQUARES 0 EXTEND ACT TO NEW SOFFIT Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart • 1 — Add Reliable Model G5-56 Standard Response 165° Pendent 1/2 x 1/4 • 14 — Relocate Reliable Model G5-56 Standard Response 165° Pendent 1/2 x 1/2 • 1— Plug Reliable Model G5-56 Standard Response 165° Pendent 1/2,x 1/2 • E — Existing pendent no change • E — Existing upright no change FlexHead Spnnkler Drop Corrugated stainless steel hose with stainless steel bral available in 2', 3',4',5' & 6' Iegnths . M1ulU-Port Bracket Adjustable Hub FLEXJIEAD INDUST RIES'L.. Flexheadr ommercial Ceilirig Unit T -Bar Ceiling installation Model #2024,2036.2048,2060,2072 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP DEAN/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING FAL STEEL JOIST/TRUSS HANGER DETAIL NTS macyy JCPemey WASHINGTON STATE CERTIFICATE OF COMPETENCY PRE PROTECTION SPRINKLER SYSTEMS John J. Abel 9760 -0591 -CG Level3 n Fir- Protector), Inc NF CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 - PH. (425) 481-7869 Signature TALL'S CAMERA Southcenter Mall Space F664 Tukwila, WA 98188 DATE: 2.22 44, DRAWN: [ SCALE: F\ID FEB L7 2014 FIRE loCI LL'S IAMERA FIRE ALARM SYSTEJ\i ADDITION KWILA, ',' ASHINON SHEET NUMBER SHEET TITLE FA -01 SYSTEM I N FO MATI O \ FA -02 TYPICAL WHI\G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SI\GLE LINE DIAGAIV FA -04 FRE ALARM SYSTEM PLAN 0 Without Comments As Noted in Red Per The Attached Letter ese pians have been reviewed by The Tukwila Fire 2'iention'Bureau for.conformance with current City Jndards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. ,Additions; deletions or revisions to these drawings after this date will void this acceptance and will require ai. resubmittal of revised drawings for subsequent appro acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bu eau. Date �-�?-I"( By; 51% '"- SHEET INDEX TUKWILA FIRE DEP/-' RTMET Pease call 206-575-44.07 and give this Fire. Permit No. and exact acklress for shut- down or a!storation approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing WISE SCHEDULE A\D CONDUIT FILL CHA WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.0. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE Y\ITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROS/IDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMA SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 4 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD FT:11 INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING )) FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM II 3 LEVELS /i 171,2755f E .ESSO o rb ter,,,a�,,1 I. I F4C �9tM Nfk 34 macys 4LEV250,4ELS 04'4s i t,R Rte, IKM,, '.INKS 1 J4: TALL'S CAMERA #281 lax 91EK =~:� LK S-4-7,5 r.E MCC o LAS SL,E?h AU 0,71aTAND TOO TOK.O .hy ExSTt�. JCPenney 3 tivp,s 276,468 f PAID FEB 21 2014 TUKWILA FIRE z y z fie co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 U) z 0 (1) LU W LU J w REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE 0 N N 0 z aaaaa z o° oJc cc o 1z WQw0 <Wzz c > Q= (/) 1) 2 F� LI g 05 cc N L_ H Z 0 0 z 111 (1) 0 SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/20/ 14 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN cc ba" Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved NUMBER: 8139-19 (j) I SHEET k FA -01» THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6012 DEDICA1ED EMERGENCY NO1E FOR MOf110NN. SF'ECIF1CA1X1NS SEE PRODUCT DOCIINFNTATKRI. *CONTACT RAMOS 4.0A 0 125VAC 4.0A 0 30VDC NEXT ADDRESSABLE DEVICE TSTIPCI 1f LAST DEUX - (+ FROM XLS CONTRtL PANEL (+ OR PREVIOUS ADDRESSABLE DEVICE - 0 J o 0 HTRI-R 0 0 o O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 1 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) EXI 00 LI PAD -3 00 ° INPUT INPUT TROUB E NAM NAC2 NAC3 NA04 AUX - 1 2+ 2- 2 NC C NO + - + - + - + - + - SI m 0 00 IQ-IMMO-Q._ 21M m 0 3.6k EOL 444 (-) (+) 2 SPARE SPARE SPARE (—) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) 0 WIRE DESIGNATION. NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR YITTH SHIELD #18 FPUFPLR RED (JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. I-'1 ° 00 0 ®; HTRI-R 114 1 GROUND Cc\ O o �) (+)> TO NEXT DEVICE OR (-) STOP IF LAST DEVICE (-) DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE ❑R STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER T1N TEMPERATURE: +32' F 0' C TO 100' F (38' C) HUMIDITY: -9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS USED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR -- DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX Y�c JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-651+5 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 02/20/14 z <aaaa Zit F - z o �OJ2 coiz W <,� o O Q Wzz U;w L1 co z o� ` r V f--Wc CC ND Z SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/20/14 BACKROUND PLAN PROVIDED BY: 'OB NUMBER: 8139-1./ % SHEET FA -02 P Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps EIS SWIM P Signe Etndir. Pi`Iret" on Cu ;rY Standby: Ala Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 Z1 -1 -MC -CW ©15CD 16 0.0875 ZH-MC-CW @30CD 12 0.131 ZH-MC-CW @75CD 0.222 ZH-MC-CW @95CD 0.292 ZH-HMC-CW @115CD 0.371 ZR -MC -CW ©15CD 16 0.069 1.104 ZR -MC -W ©15CD 0.064 0.192 0.03 Amps 1.326 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.326 Amps For 5 Minutes= 0.111 Amp -hours 25% Derating= 1.039 Amp -hours Total System Current Load: 1.039 Amp -hours PalUsed: 12VDC Amp -hours Notification Appliance Circuit Detail PROJECT: TALL'S CAMERA Panel: EXISTING PAD -3 POWER SUPPLY Date: February 21, 2014 Wire Resistance 2.58 CURRENT TOTAL= i436.00 2 al -MC -CW @15cd 2 ZH-MC-CW @30cd 71 -MC -CW @75cd 21 -i -MG -CW @95cd ZH-MC-CW @115cd ZR -MC -CW @15cd DEVICES 4 87 131 222 292 371 69 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E ) EOL Voltage 1741 262 0 436; 14 266 23.40i ;(WL*2)*(Rift); (Total a-ct Load) (E= I * R) 24.-E) 436 1.37 0. 0.60 23.40 SYSTEM CALCULATIONS TO NEAREST EXISTING s ss � b E ,,,^_OL POWER SUPPLY ���� S1-1 S1-2 S1-3 S1-4 15cd 15cd 30cd 30cd TO NEAREST EXISTING DATA LOOP D D D,I D � HT -R b (HT -R, 21 (TSM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: M 0 DESCRIPTION SHOP DRAWINGS DATE d 0 N N 0 o aaaaa cc 0 0 w z w J 0 z (!) 0 z aC (1) z 0 0 J 0 w co >- �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/20/14 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved ,OB NUMBER: 8139-1} FA-03� 64'-10" 12'-4" 24'-0" LEASE LINE (V.I.F.) VERIFY VERIFY 24'-O" VERIFY d Z0 co X < wcoQ w cc w z 0 E - STORE ROOM/ EMPLOYEES s SERV ,/' POS ELI S1-3 30cd SALES AREA FIRE ALARM SYSTEM PLAN DISPLAY CASE EOL S1 S1-4 30cd DISPLAY CABINET L FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 02/20/14 Zco co• O Jso cc 0 §Z W °co 2 1— • W ZL61Z co ccit) J D �o LLJ CC c — LL 1- CALE: 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:02/20/14 BACKROUND PLAN PROVIDED BY: .J9B NUMBER: 8139-1 SHEET FA -04 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved \ J r 281 SOUTHCENTER MALL ASSOCIATED PERMITS 14-F-035 14-S-040 14-S-037 1 22g - OttiLlr4I SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470010 Site Address: 281 Southcenter Mall Tukwila, WA 98188 Suite Number: Floor: Tenant Name: Tal l's Camera New Tenant? - Yes ❑ - No Property Owner's Name: Westfield Property Tax Dept. Mailing Address: POB 130940, Carlsbad, CA 92013 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 E-mail Address: kveliz@guardiansecurity.com Total number of new/relocated devices or sprinkler heads: 8 Valuation of Project (contractor's bid price): $ 2000 City State Zip Fax Number: 206.628.4990 Scope of Work (please provide detailed information): Adding 8 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 NE t OR AUTHORIZ s 1 AGENT: Signature: • _ Date: ` ` 1 Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 01144 44tt SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 255\ Cb � l (" n lC�� 1 Y7'7ck\) Suite Number: � Floor: Tenant Name: ----Va\\S C Y Y \ r (1 New Tenant? K.- Yes ❑ - No Property Owner's Name: \oe c, - -\-ENA. �j- Mailing Address: CONTACT PERSON -if there are questions about the submittal. Name: Company Name: `CCS. i�1Yl� f) City State Zip Day Telephone: Z l / 7CC)f(�9 Mailing Address: VO X \2.\\J V f l 1` c�'e--e\c, \o/ O L E-mail Address: Total number of new/relocated devices or sprinkler heads: 1 Stater of Ci Fax Number: 6l2 c '� �f \l1 1 recuac Valuation of Project (contractor's bid price): $ \ �` Cs( cC , �P\ecce,C 144)) Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: n I Signature: -,��� / to ��� Date: 2:2-60 ' J Print Name: *SJ RCa , Q77 Plan Permit App.doc Day Telephone: O 1. 7M0 (o9 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Tall's Camera 281 Southcenter Ma;; Permit No.: 14-S-040 Date: March 3, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. 02/27/2014 15:55 4254818695 FAX TRA N SJ\ I I TTAL CROWN FIRE FILE Fax No. CROWN FIRE PROTECTION, INC. 2.27.14 Fire Prevention Bureau Tukwila Fire Department / Al Demo Permit ( ItIl3�}�I11� Number 01 1'a!2 -.t.• (Inciudinfl ( fid cr) PAGE 01101 1206.575.4439 1 • CERTITE � CATS OFC OMPET&NRY FIRE PROTECTION SPRINKLER S''a 1 f John J. Abet 19700-0 1 -CG Level r P►OteCtiOn„ inC CR ■ r ✓ 0 Urgent 21For Review 0 Please Comment 0 Please Reply Cristie Ogland Comments PH:425.481.7669 FX:425.481.8695 Please provide a demo permit to remove (4) sprinkler heads that are in the way of the framing at the Tall's Camera project at 281 Southcenter Mall. The building permit tf is D13-0379. Please lei us know if you have any questions. That s-- TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. 14-5-a3-! and exact address for shut- down or restoration approval. P.O. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX: 425.481.8695 r ACCEPTED o Without Comments o As Noted in Red ,Er Per The Attached Letter These pians have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City tandards. Acceptance is subject to errors and omissions which do not authorize violations of adopted ;' andards and ordinances. The responsibility for the dequacy of design rests totally with the designer. dditions, deletions or revisions to these drawings after rlrls date will void this acceptance and will require a .-e3ubmittal of revised drawings for subsequent approval. 1=anal acceptance is subject to-fleld test and inspection by me Tukwila Fire Prevention Bureau. Date: 3 - - % `' 6y: SII TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. / L,/ . o&I0 and exact address for shut- down hutdown or restoration approval. EXISTING (3\J e, CEILING 14 0 I-- LINE OF EXISTING MALL FASCIA ABOVE EXISTING CEILING EXISTING ACT CEILING, PAINT TO MATCH EXISTING REFLECTED CEILING PLAN at HIGH CEILING SCALE: 1/4"=r--0" EXISTING 2'x2' ACT CEILING TILE WITH TEGULAR EDGE/REVEAL 'ARMSTRONG' FINE FISSURED SECOND LOOK, 6"x6" SQUARES 0 EXTEND ACT TO NEW SOFFIT Design per NFPA 13, Ordinary Hazard Group 2 All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart • 1 — Add Reliable Model G5-56 Standard Response 165° Pendent 1/2 x 1/4 • 14 — Relocate Reliable Model G5-56 Standard Response 165° Pendent 1/2 x 1/2 • 1— Plug Reliable Model G5-56 Standard Response 165° Pendent 1/2,x 1/2 • E — Existing pendent no change • E — Existing upright no change FlexHead Spnnkler Drop Corrugated stainless steel hose with stainless steel bral available in 2', 3',4',5' & 6' Iegnths . M1ulU-Port Bracket Adjustable Hub FLEXJIEAD INDUST RIES'L.. Flexheadr ommercial Ceilirig Unit T -Bar Ceiling installation Model #2024,2036.2048,2060,2072 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP DEAN/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING FAL STEEL JOIST/TRUSS HANGER DETAIL NTS macyy JCPemey WASHINGTON STATE CERTIFICATE OF COMPETENCY PRE PROTECTION SPRINKLER SYSTEMS John J. Abel 9760 -0591 -CG Level3 n Fir- Protector), Inc NF CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 - PH. (425) 481-7869 Signature TALL'S CAMERA Southcenter Mall Space F664 Tukwila, WA 98188 DATE: 2.22 44, DRAWN: [ SCALE: F\ID FEB L7 2014 FIRE loCI LL'S IAMERA FIRE ALARM SYSTEJ\i ADDITION KWILA, ',' ASHINON SHEET NUMBER SHEET TITLE FA -01 SYSTEM I N FO MATI O \ FA -02 TYPICAL WHI\G AND MOUNTING DETAILS FA -03 SYSTEM CALCULATIONS AND SI\GLE LINE DIAGAIV FA -04 FRE ALARM SYSTEM PLAN 0 Without Comments As Noted in Red Per The Attached Letter ese pians have been reviewed by The Tukwila Fire 2'iention'Bureau for.conformance with current City Jndards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. ,Additions; deletions or revisions to these drawings after this date will void this acceptance and will require ai. resubmittal of revised drawings for subsequent appro acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bu eau. Date �-�?-I"( By; 51% '"- SHEET INDEX TUKWILA FIRE DEP/-' RTMET Pease call 206-575-44.07 and give this Fire. Permit No. and exact acklress for shut- down or a!storation approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing WISE SCHEDULE A\D CONDUIT FILL CHA WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE C STROBE SYNC TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) S' STROBE CIRCUIT - RETURN TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) V' SPEAKER CIRCUIT - RETURN TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.0. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE Y\ITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROS/IDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMA SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY EX EX 1 1 2 4 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP SMOKE DETECTOR HFP-1 1 W/ SIEMENS (PHOTO -ADDRESSABLE) DB -11 BASE 4S DEEP W/ 1 G RING CEILING ® DUCT DETECTOR D AD2-P W/ SIEMENS HFP-11 DET. DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD FT:11 INTERFACE MODULE WITH RELAY HTRI-R SIEMENS 4S DEEP BOX VERIFY IN FIELD FIRE ALARM HORN STROBE (CEILING MOUNT) ZH-MC-CW SIEMENS 4S DEEP BOX CEILING )) FIRE ALARM STROBE (CEILING MOUNT) ZR -MC -CW SIEMENS 4S DEEP BOX CEILING A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND NORDSTROM II 3 LEVELS /i 171,2755f E .ESSO o rb ter,,,a�,,1 I. I F4C �9tM Nfk 34 macys 4LEV250,4ELS 04'4s i t,R Rte, IKM,, '.INKS 1 J4: TALL'S CAMERA #281 lax 91EK =~:� LK S-4-7,5 r.E MCC o LAS SL,E?h AU 0,71aTAND TOO TOK.O .hy ExSTt�. JCPenney 3 tivp,s 276,468 f PAID FEB 21 2014 TUKWILA FIRE z y z fie co 0' 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 U) z 0 (1) LU W LU J w REV. BY: 0 M 0 DESCRIPTION SHOP DRAWINGS DATE 0 N N 0 z aaaaa z o° oJc cc o 1z WQw0 <Wzz c > Q= (/) 1) 2 F� LI g 05 cc N L_ H Z 0 0 z 111 (1) 0 SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/20/ 14 BACKROUND PLAN PROVIDED BY: WIRE DESIGNATION GENERAL NOTES SITE PLAN cc ba" Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved NUMBER: 8139-19 (j) I SHEET k FA -01» THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. TUBE OUTLET SAMPLING TUBE INLET SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL 120VAC-6012 DEDICA1ED EMERGENCY NO1E FOR MOf110NN. SF'ECIF1CA1X1NS SEE PRODUCT DOCIINFNTATKRI. *CONTACT RAMOS 4.0A 0 125VAC 4.0A 0 30VDC NEXT ADDRESSABLE DEVICE TSTIPCI 1f LAST DEUX - (+ FROM XLS CONTRtL PANEL (+ OR PREVIOUS ADDRESSABLE DEVICE - 0 J o 0 HTRI-R 0 0 o O NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C -CABLE C -CABLE 1 0 FROM PREVIOUS > (+) ADDRESSABLE > DEVICE (-) EXI 00 LI PAD -3 00 ° INPUT INPUT TROUB E NAM NAC2 NAC3 NA04 AUX - 1 2+ 2- 2 NC C NO + - + - + - + - + - SI m 0 00 IQ-IMMO-Q._ 21M m 0 3.6k EOL 444 (-) (+) 2 SPARE SPARE SPARE (—) NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. (+) 0 WIRE DESIGNATION. NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TWISTED PAIR YITTH SHIELD #18 FPUFPLR RED (JACKET) *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. I-'1 ° 00 0 ®; HTRI-R 114 1 GROUND Cc\ O o �) (+)> TO NEXT DEVICE OR (-) STOP IF LAST DEVICE (-) DRY CONTACTS TO VAV FAN SHUTDOWN PROVIDED BY MECH/ELEC. DUCT DETECTOR, TEST SWITCH & RELAY MODULE WIRING DETAIL (+) HORN STROBE OR STROBE ONLY 80" A.F.F. (OR UNLESS OTHERWISE SPECIFIED) 4S DEEP BOX HORN STROBE & STROBE WALL MOUNTING DETAIL HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE ❑R STROBE ONLY POWER SUPPLY & RELAY MODULE WIRING DETAIL HONR STROBES & STROBES ONLY WIRING DETAIL TO NEXT DEVICE OR END OF LINE TYPICAL WIRING AND MOUNTING DETAILS CEILIN TILE NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER T1N TEMPERATURE: +32' F 0' C TO 100' F (38' C) HUMIDITY: -9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR —> FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN (-) > DATA IN (+) > DEVICE IS USED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION WITH DUCT HOUSINGS AD -11P OR AD-11XPR -- DB -11 STANDARD SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL SUPPORT BRIDGE 4' SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING > TO NEXT ADDRESSABLE DEVICE SUPPORT BRIDGE 4" SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL JUNCTI❑N BOX MOUNTED ON CEILING FLEX Y�c JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT 0 0 TO NEXT DEVICE CADDY BAR SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST FAX (206) 628-4990 TEL. (206) 622-651+5 RELEASE/REVISIONS REV. BY: DMG DESCRIPTION SHOP DRAWINGS DATE 02/20/14 z <aaaa Zit F - z o �OJ2 coiz W <,� o O Q Wzz U;w L1 co z o� ` r V f--Wc CC ND Z SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/20/14 BACKROUND PLAN PROVIDED BY: 'OB NUMBER: 8139-1./ % SHEET FA -02 P Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 0.000 AD2-P 1 0.0635 0.0635 0.064 0.064 HTR -R 2 0.009600 0.0096 0.021 0.042 0.0731 Amps 0.106 Amps EIS SWIM P Signe Etndir. Pi`Iret" on Cu ;rY Standby: Ala Device Type Qty Amps Total Amps Total Main System Board 1 0.03 0.03 0.030 0.030 Z1 -1 -MC -CW ©15CD 16 0.0875 ZH-MC-CW @30CD 12 0.131 ZH-MC-CW @75CD 0.222 ZH-MC-CW @95CD 0.292 ZH-HMC-CW @115CD 0.371 ZR -MC -CW ©15CD 16 0.069 1.104 ZR -MC -W ©15CD 0.064 0.192 0.03 Amps 1.326 Amps Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.326 Amps For 5 Minutes= 0.111 Amp -hours 25% Derating= 1.039 Amp -hours Total System Current Load: 1.039 Amp -hours PalUsed: 12VDC Amp -hours Notification Appliance Circuit Detail PROJECT: TALL'S CAMERA Panel: EXISTING PAD -3 POWER SUPPLY Date: February 21, 2014 Wire Resistance 2.58 CURRENT TOTAL= i436.00 2 al -MC -CW @15cd 2 ZH-MC-CW @30cd 71 -MC -CW @75cd 21 -i -MG -CW @95cd ZH-MC-CW @115cd ZR -MC -CW @15cd DEVICES 4 87 131 222 292 371 69 TOTAL mA= Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop (E ) EOL Voltage 1741 262 0 436; 14 266 23.40i ;(WL*2)*(Rift); (Total a-ct Load) (E= I * R) 24.-E) 436 1.37 0. 0.60 23.40 SYSTEM CALCULATIONS TO NEAREST EXISTING s ss � b E ,,,^_OL POWER SUPPLY ���� S1-1 S1-2 S1-3 S1-4 15cd 15cd 30cd 30cd TO NEAREST EXISTING DATA LOOP D D D,I D � HT -R b (HT -R, 21 (TSM FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: M 0 DESCRIPTION SHOP DRAWINGS DATE d 0 N N 0 o aaaaa cc 0 0 w z w J 0 z (!) 0 z aC (1) z 0 0 J 0 w co >- �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 02/20/14 BACKROUND PLAN PROVIDED BY: SINGLE LINE DIAGRAM Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved ,OB NUMBER: 8139-1} FA-03� 64'-10" 12'-4" 24'-0" LEASE LINE (V.I.F.) VERIFY VERIFY 24'-O" VERIFY d Z0 co X < wcoQ w cc w z 0 E - STORE ROOM/ EMPLOYEES s SERV ,/' POS ELI S1-3 30cd SALES AREA FIRE ALARM SYSTEM PLAN DISPLAY CASE EOL S1 S1-4 30cd DISPLAY CABINET L FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 02/20/14 Zco co• O Jso cc 0 §Z W °co 2 1— • W ZL61Z co ccit) J D �o LLJ CC c — LL 1- CALE: 1/4''=1'0” DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:02/20/14 BACKROUND PLAN PROVIDED BY: .J9B NUMBER: 8139-1 SHEET FA -04 Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved \ J