HomeMy WebLinkAboutPP - 161 SOUTHCENTER MALL - RAINFOREST CAFÉ - PERMITS AND PLANS161 SOUTHCENTER MALL
ASSOCIATED PERMITS
16-S-248
850230
443ist"444
SITE LOCATION
Site Address:
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.:
Suite Number: , Floor:
Tenant Name: I l n� �O \ �� r New Tenant? D - Yes ❑ - No
Property Owner's Name: 96 i 11 n'lfl (
Mailing Address:_ 2f . Ceri \ -or
tate Zip
City
CONTACT PERSON -if there are questions\\about the submittal.
Name: je56CC. Q,p� fl :son Day Telephone:
Company Name: Tei 1 o n F, rt'_ fin} -,r ton t I nc.
Mailing Address: VD ?i 1 \7 \\2 11\ C"r-�� �� ��s S.a.
City _ ta
E-mail Address: �'QS6jk CCkC ft) V.) (T Y \ Fax Number: 1-42_5-y Sa\a - s Zi i
gt
Total number of new/relocated devices or sprinkler heads:
� 1.3
Valuation of Project (contractor's bid price): $ \'t cO
Scope of Work (please provide detailed information):
11\4M _pefy)ev\-s LT -rviar\-\-
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING WNER OR AUTHORIZED AGENT: G `t
Signature: .M?J1C .*4.3c-noen Date: 1D I\ \it
Print Name: jSSC(t ?i3bi as on Day Telephone: 42—-48\'10(.06\
Plan Permit App.doc
1t2/13
TFD FP Form 8
NRG FRE CONSULTING
December 1, 2016
Jessica Robinson
President
Crown Fire Protection, Inc
PO BOX 12113
Mill Creek, WA 98093
Cell (425) 583-3890
nrgfl rrconsulting.com
irmai
Re: Ding Tai Fung — Westfield Southcenter Mall — Tukwila, WA (161 Southcenter Mall)
Tenant Improvements: New restaurant build -out
Fire Sprinkler System Submittal Plan Review Letter
Dear Jessica:
We have reviewed the fire sprinkler drawing sheet 1 of 1 that you prepared (dated 10/2016). This submittal package
shall be considered REVIEWED WITHIN GENERAL COMPLIANCE OF NFPA 13. Contractor to review comments below
and provide complete compliance with all items:
1. Please provide equipment cut sheets for all materials (heads, piping, hangers, fittings, etc) as part of the
project closeout package. All equipment to be UL and/or FM listed for use as automatic fire sprinkler systems.
2. Ensure that coolers and freezers are not provided with storage above 5 ft AFF.
3. Coordinate for all obstructions in the field per NFPA 13 requirements. This includes lighting fixtures, HVAC
equipment, structural elements, etc. Additional sprinkler heads may be required for compliance.
4. Contractor to coordinate with building owner and local fire authority for any sprinkler system downtime
during the remodel process. Contractor is responsible for coordinating any required fire watch for the tenant
improvement space. System to be fully charged and operational at completion of tenant improvement.
5. We remind the contractor that while this review is an integral part of this project, it does not relieve them
from their responsibility to comply with the applicable requirements of Westfield Southcenter Mall along with
all currently mandated codes, standards, insurer, and local ordinances of the jurisdiction. Nor should this
examination be construed as a check of every item in the submitted documents and does not prevent
authorities from hereafter requiring corrections of errors in plans or installation.
Thank you for the opportunity to review this submittal pac. ;• : - look forward to a successful conclusion to this
project. Please call if you should have any questions o
Sincerely, Regards,
�---� Joh
Sean Pisoni, CET
Fire Protection Consultant
NRG Fire Consulting
John Camp
Fire Protect'
NRG Fire Consult
Ily signed by John D.
pbell
2016.12.01 13:56:18 -06'00'
NRG Fire Consulting — 7511 Greenwood Ave N #600 — Seattle, WA 98103 — 206.789.0165
Cristie Ogland
Crown Fire Protection, INC
PO BOX 12113, Mill Creek, WA
(425)481-7669
(425)481-8695 CC/BCC Block: Din Tai Restaurant — Westfield Mall
cristie@crownfp.com
October 31, 2016
Al Metzler
Tukwila Fire Prevention
6300 Southcenter Blvd, Suite 209
Tukwila, WA 98188
Crown Fire Protection has submitted for a fire sprinkler permit
at Din Tai Restaurant at 161 Southcenter Mall inside of the
Westfield Mall.
We propose to add 8 dry pendent heads and 105 quick
response pendents. We do not think this system needs to
hydraulically calculated because this past year we plugged
over 100 sprinkler drops that were in this space for the
Rainforest Cafe and turned this into upright heads. Our plan is
to take these same outlets to use for the sprinkler heads at
Din Tai.
Thank you for your help with this matter.
Sincerely,
CU:dt:e
Cristie Ogland
Engineer
Crown Fire Protection, INC
r+
ERTIIrmiATE�COMPETENCY
o
FIRE PROTECTION SPRINKLER SYSTEMS
John J. Abel
97600691 -CQ Level 3
Crown Are Protection, Inc.
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Ding Tai Fung
Permit No.: 16-S-248
Date: December 8, 2016
Reviewer: Don Tomaso
Fire Marshal
(206) 575-4407 option # 2 (Inspection Requests)
(206) 971-8723 (Plan Review Questions)
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the (last length of
pipe but within 6' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2" for 1"-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2 for pipe size 2 1/2 inches and larger.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-02, section 9.6.2.6.2 (e).
• Ceilings used for flex drop attachments shall comply with ASTM C 635 and
ASTM C 636 per section 9.2.1.3.3.2.
• Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a
suspended ceiling, a hanger(s) attached to the structure shall be required to
ensure that the maximum unsupported length does not exceed 6 ft. (9.2.1.3.3.3).
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
• Comply with obstructed/non-obstructed construction rules for sprinkler head
placement.
• Sprinkler heads spaced closer than 6 ft. apart must be baffled.
• Modifications involving 20 or more sprinkler heads require hydrostatic test and
system isolation if necessary.
• For dry pipe and double interlock pre -action systems in addition to the standard
hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24
hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the
24 hours shall be corrected.
All code references are NFPA 13, 2013 Edition.
Multi—Port Bracke,±_\
FlexHead Sprinkler Drop
Corrugated stainless steel hose with stainless steel braid
available in 2', 3',4',5' & 6' legnths
Adjustable Hub
FLEXHEAD
INDUST 0155
Flexheadbommercial Ceiling Unit
T -Bar Ceiling Installation
Model #2024,2036,2048,2060,2072
PROJECT & BUILDING INFORMATION CONTACT INFORMATION
PROJECT ADOR2SB:
WEETFEILO SOUTHCENTER MALL
181 SOUTHCENTER MALL
SEATTLE, WA 98188
ASSESSOR'S PARCEL HUUSER: 9202474170
LEGAL DESORPTION. WEA SOUTHCENTER LLC SSP PER SNP
REC V01.256809 1-4010CH REALACES
SSP REO VOL 249 PGS 71-8418141 PAR0LL
ATUKWLA SSIP
9110-032 0EC4201010210007E5
TUC- TUKWILA URBAN CENTER
EXISTING OCCUPANCY CLASSIFICATION: M (MERCANTILE)
TYPE OF CONSTRUCTION: 0
PROJECT AREA 9.288 S.F.
TOTAL STORIES: 1
PROJECT STORY: GROUND
FIRE SPRINKLERED
YES- FULLY SPRINRLERED
Project-- SAR!
mocy"5
WESTFIELD SOUTHCENTER MALL
APPLICANT:
TENANT-
ARCHITECT/DESIGNER:
CHINIEY/RECHE ASSOCIATES
1515 MELROSE AVENUE
SUITE 200
SEATTLE. WA 50122
CONTACT: SERGIO CMN -LEY
TEL 2C5918 1501
FAX: 206.915 3449
EMAIL: serg0racnneyn...ram
DING TAI FLING
700 S EI.LEVUE WAY NE F280
BELLEVUE, WA 98004
CONTACT: DAVID WASIELEWSKI
TEL: 208953.0770
mvev s®565m1cu"
CHIN-LEYIRECHE ASSOCIATES
1518 MELROSE AVENUE -
SUITE 200
SEATTLE, WA 98122
CONTACT: SERGIO CHIN -LEY
TEL: 206.939 1501 •
FAX 218.935.3449
EMAIL: eery PQchirieyreche.com
® VICINITY MAP
1"X1"X1/2" TEE
WITH 1/2" PLUG
DRY PENDENT
BARREL
DRILL 1-3/4" HOLE
SEAL W/ 1/2N DEEP
BEAD OF SILIC❑NE
AT TOP
DRY PENDENT HEAD
FOR USE IN ALL FREEZERS
AND COOLER BOXES EXCEPT
PRODUCE & FLORAL COOLERS
1' DROP
TOP PANEL OF COOLER
OR FREEZER BOX (N,ILC.)
DRY PENDENT HEAD
ESCUTCHEON
14' DRY PENDENT MINIMUM
COOLER / FREEZER SPRINKLERS
NO SCALE
TENANT SPRINKLER PLAN
SCALE: 1/8" = 1'-0"
SPRINKLERS
PROJECT TOTALS
SPRINKLER HEAD LEGEND :
SYMBOL
S/N
ORIFICE
NPT
K -FACT.
HEAD
FINISH
PLATE
FINISH
TEMP.
QUAN.
RELIABLE QUICK RESP RECESSED DRY PENDENT F3QR
•
R5714
1 /2"
1/2"
5.6
CHR
CHR
200e
8
RELIABLE QUICK RESP RECESSED PENDENT F1FR56
o
R1414
1/2"
1/2"
5.6
CHR
CHR
155°
105
TOTAL SPRINKLERS = 1 1 3
0 4' 8' 16'
24'
T
GENERAL NOTES
SPRINKLER SYSTEM DESIGN PER }N.F:P.A.#13 - 2010
ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED
ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS
ORDINARY HAZARD OCCUPANCY
130 SF MAX PER SPIRNKLER
1"-11/4" THREADED PIPING TO BE 'DYNA-THREAD'
PROVIDE HANGERS ON 1" ARM -OVERS LONGER THAN 12" (OVER 100 PSI STATIC PRESSURE)
GENERAL LEGEND
—D
—4
BOD
BOB
BOJ
FOS
FOW
EARTHQUAKE BRACING
PIPE HANGER
GROOVED CAP
RIGID COUPLING ( UNLESS NOTED )
'CAP
PLUG
CENTERLINE
HYDRAULIC REFERENCE POINT
CENTERLINE PIPE TO BOTTOM OF DECK
CENTERLINE PIPE TO BOTTOM OF BEAM
CENTERLINE PIPE TO BOTTOM OF JOIST
FACE OF STUD
FACE OF WALL
FOC
AFF
CH
R.C.
cc"
4
F
E/C
c/c
c/E
GG
TG
TxF
ATR
FACE OF CONCRETE
ABOVE FlNISHED FLOOR
CEILING HEIGHT
REDUCING COUPLING
OUTLET COUPLING
WELDED OUTLET
"FIT" FITTING
END TO CENTER
CENTER TO CENTER
CENTER TO END
GROOVE/GROOVE
THREAD/GROOVE (ALSO "GT")
THREAD/"FIT" (ALSO "FxT")
ALL—THREAD ROD
i a,j T� r � ,qq P-- i ;i m �y
L'a:'�JiL-t 2 e.,t DrP R M 1
P;ezDs::;cF2i: 205-575 c 4O7 arld
:;:ve th Fire Pe mit-NO
e
end exact Edi. reSS for shut-
. -;own or on' 1 n approve.
LEGE\D
— — — — — EXISTING SPRINKLER PIPING
NEW SPRINKLER PIPING
�....-EXISTING 1" OUTLET
—e
Q,�-PLUG @ EXISTING 1" OUTLET
---0—
NEW PENDENT SPRINKLER
® NEW DRY PENDENT SPRINKLER
l_I Without Comments
El As Noted in Red
Per The Attached Letter
plans have been reviewed by The Tukwila Fir
r 1 ' r;tinn Bureau for conformance with current Cit,/
.:f:.'..I-?dards. Acceptance is subject to errors and
or.isti,lons which do not ,:-i `':1+Ize violations of adopted
,t-`r:dards and crdiitalic:_:; T"s;r' 1-?sponslbiiity for th
.yr; `u icy offdesion r.:,.,11: ... Rh rhe designer. iter
Ar k ticnS, r_Ieletioil [ : �':Vi j011 I•() .testi drawings G iter
wiil :. '"' ' _-i''.: )ta . C ;t ;[i will rewire a
,'esubrnittai of r .': c:...ir _ _Sib equent app oval,
'=root acceptaoC : is .. • t:., d.: ?:o r1i0 :. _;i and inspect'
The Tukv'Iia
m by
WASHINGTON STATE
CERTIFICATE OF COMPETENCY
FIRE PROTECTION SPRINKLER SYSTEMS
John J. Abel
9780-0691•OG Level 3
Crown Firs Protection, inc.
PAID
•3T 2015
TUKWILA FIRE
,.�‘
CROWN
FIRE PROTECTION
INCORPORATED
P.O. BOX 12113
MILL CREEK, WASHINGTON 98082-0113
PH. (425) 481-7669
DING TAI FUNG
NEW RESTAURANT
WESTFIELD SOUTHCENTER MALL
161 SOUTHCENTER MALL
TUKWILA, WASHINGTON 98188
DATE: 10/ 2016 I DRAWN: C.O. I SCALE: AS NOTED
1 OF 1
•
co
Q1
M
C9
z
z
ca
•
f4
•
2
J
•I
•
i
t
` I
t
•
RE- LocPi E5
t4 — NEW LoGAT io tJ
I
C E 1 L 1 tis
R E r1 a D C
%- 1-0
7
/3 -0 CEl_.1
r
fz
tz-0"c& IL,
14-
14
A L L_
\, rna`n ► r n\� f \ \
•
R HLA- L /1
•
APPROVED
V 4SNi IGTSEASUR 6WARSATH 6 BUREAU
!UN 1 3 1985
AS meeting requirements of this Bureau for classification as spnnklered;
WOW.%'stem changes or additions as recommended on the attached
theet(`*) will result in improved rates. Acceptance applies to plans as
submitted end for construction and occupancy shown thereon. Euaished
lnattllatfnn subject to inspection for final acceptance.
All comments. ,11"l-'" ' anci acceptances relate exclusively to retatm
effect of varnu c^titir ens uaon fere insurance rates They are not ti
be construed a-- L al , in a.ty way upon the question of whether "due
care" has a been to prop with It erecognPized b liability
m:
Injury or damage to property.
result in loss stili exist.
Com,'/,t
TED
WITHOUT COMMENTS.
NOTED IN RED
PER THE ATTACHED LETTER
The drawings affixed he.retohave been
reviewed and accepted by the City of
Tu'.c.tella Fire Dept. A: Haiti- n„ d Ietf bfl5
or revisions to these
'date will t•'.•-....ijt„.m,',-; and will
equine a r s: amitt:S cf revbs.i dr 'Arte,
�-. -pie as ° .:N i =`'r= 1121d,
tai rzp.=,,---ztative cf 11115
''
t _� ,•fir,
-
t
CS T
e
K UJIL:':14
N
J
0
m
2
>-
V)
0
0
z
N
CHECK VALVE
W/ALARM VALVE
W/DELUGE VALVE
CC CC
W W
N V)
_
FL
MOTOR BELL
. z
0
0
t-=
a
W
La▪ i
CC) W
CC
0 17
W M_ N
N < J J
CC C4 La.
1 1 1 1 1 1 1 1
M.rilOeCa�x
DAD
>Z
Z
L)
O z > Q
• �c7
0
03 Q Q U o W
J
oN YW>> iotai ONyV)7=zoOv )
r�z
,MZ U=N Q=
3
IQo
.Qz f 1 j 1 1 1 1 1 1
cn-�®4>—t ZIrr
POST
0
z
W
J
CC
W
c7
Z
$1, — EXPANSION SHELL, ROD &
W
W
C9
W
p
N
- J
0
OD
>-
N
CC
W
J
Y
z_
'a
w
J
F—
J J t Lt 0-
O O ~ - D
0 0 zO
L0 0 .•+
0000w
00Z J
= z = Z W 0 <
c7 w � w a,
IX Z IX • Z >' ? p
Cl- W a w it J
OaOapt�01
1111111
ola®ooV.D
Q
t
r
Superrar Fire Fratedion
i= iii f ti '°i
r
7-1.114111.01
�- K1- - w- -
.-01 -F- IRE DEPARTMENT
ve
'e°ab-44Qnthis l 6'02t7®aoq factafor shit-
wn°rrs°adonapproa/-
i
Kt '--L.oCATIO►_l
N i,
rj
f)
0
d
f
0
REVISIONS
Y
J
u
a
0
It
0
u
w
0
0
C
Sim
4-.
O
c
V
161 SOUTHCENTER MALL
ASSOCIATED PERMITS
16-S-248
850230
443ist"444
SITE LOCATION
Site Address:
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.:
Suite Number: , Floor:
Tenant Name: I l n� �O \ �� r New Tenant? D - Yes ❑ - No
Property Owner's Name: 96 i 11 n'lfl (
Mailing Address:_ 2f . Ceri \ -or
tate Zip
City
CONTACT PERSON -if there are questions\\about the submittal.
Name: je56CC. Q,p� fl :son Day Telephone:
Company Name: Tei 1 o n F, rt'_ fin} -,r ton t I nc.
Mailing Address: VD ?i 1 \7 \\2 11\ C"r-�� �� ��s S.a.
City _ ta
E-mail Address: �'QS6jk CCkC ft) V.) (T Y \ Fax Number: 1-42_5-y Sa\a - s Zi i
gt
Total number of new/relocated devices or sprinkler heads:
� 1.3
Valuation of Project (contractor's bid price): $ \'t cO
Scope of Work (please provide detailed information):
11\4M _pefy)ev\-s LT -rviar\-\-
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING WNER OR AUTHORIZED AGENT: G `t
Signature: .M?J1C .*4.3c-noen Date: 1D I\ \it
Print Name: jSSC(t ?i3bi as on Day Telephone: 42—-48\'10(.06\
Plan Permit App.doc
1t2/13
TFD FP Form 8
NRG FRE CONSULTING
December 1, 2016
Jessica Robinson
President
Crown Fire Protection, Inc
PO BOX 12113
Mill Creek, WA 98093
Cell (425) 583-3890
nrgfl rrconsulting.com
irmai
Re: Ding Tai Fung — Westfield Southcenter Mall — Tukwila, WA (161 Southcenter Mall)
Tenant Improvements: New restaurant build -out
Fire Sprinkler System Submittal Plan Review Letter
Dear Jessica:
We have reviewed the fire sprinkler drawing sheet 1 of 1 that you prepared (dated 10/2016). This submittal package
shall be considered REVIEWED WITHIN GENERAL COMPLIANCE OF NFPA 13. Contractor to review comments below
and provide complete compliance with all items:
1. Please provide equipment cut sheets for all materials (heads, piping, hangers, fittings, etc) as part of the
project closeout package. All equipment to be UL and/or FM listed for use as automatic fire sprinkler systems.
2. Ensure that coolers and freezers are not provided with storage above 5 ft AFF.
3. Coordinate for all obstructions in the field per NFPA 13 requirements. This includes lighting fixtures, HVAC
equipment, structural elements, etc. Additional sprinkler heads may be required for compliance.
4. Contractor to coordinate with building owner and local fire authority for any sprinkler system downtime
during the remodel process. Contractor is responsible for coordinating any required fire watch for the tenant
improvement space. System to be fully charged and operational at completion of tenant improvement.
5. We remind the contractor that while this review is an integral part of this project, it does not relieve them
from their responsibility to comply with the applicable requirements of Westfield Southcenter Mall along with
all currently mandated codes, standards, insurer, and local ordinances of the jurisdiction. Nor should this
examination be construed as a check of every item in the submitted documents and does not prevent
authorities from hereafter requiring corrections of errors in plans or installation.
Thank you for the opportunity to review this submittal pac. ;• : - look forward to a successful conclusion to this
project. Please call if you should have any questions o
Sincerely, Regards,
�---� Joh
Sean Pisoni, CET
Fire Protection Consultant
NRG Fire Consulting
John Camp
Fire Protect'
NRG Fire Consult
Ily signed by John D.
pbell
2016.12.01 13:56:18 -06'00'
NRG Fire Consulting — 7511 Greenwood Ave N #600 — Seattle, WA 98103 — 206.789.0165
Cristie Ogland
Crown Fire Protection, INC
PO BOX 12113, Mill Creek, WA
(425)481-7669
(425)481-8695 CC/BCC Block: Din Tai Restaurant — Westfield Mall
cristie@crownfp.com
October 31, 2016
Al Metzler
Tukwila Fire Prevention
6300 Southcenter Blvd, Suite 209
Tukwila, WA 98188
Crown Fire Protection has submitted for a fire sprinkler permit
at Din Tai Restaurant at 161 Southcenter Mall inside of the
Westfield Mall.
We propose to add 8 dry pendent heads and 105 quick
response pendents. We do not think this system needs to
hydraulically calculated because this past year we plugged
over 100 sprinkler drops that were in this space for the
Rainforest Cafe and turned this into upright heads. Our plan is
to take these same outlets to use for the sprinkler heads at
Din Tai.
Thank you for your help with this matter.
Sincerely,
CU:dt:e
Cristie Ogland
Engineer
Crown Fire Protection, INC
r+
ERTIIrmiATE�COMPETENCY
o
FIRE PROTECTION SPRINKLER SYSTEMS
John J. Abel
97600691 -CQ Level 3
Crown Are Protection, Inc.
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Ding Tai Fung
Permit No.: 16-S-248
Date: December 8, 2016
Reviewer: Don Tomaso
Fire Marshal
(206) 575-4407 option # 2 (Inspection Requests)
(206) 971-8723 (Plan Review Questions)
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the (last length of
pipe but within 6' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2" for 1"-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2 for pipe size 2 1/2 inches and larger.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-02, section 9.6.2.6.2 (e).
• Ceilings used for flex drop attachments shall comply with ASTM C 635 and
ASTM C 636 per section 9.2.1.3.3.2.
• Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a
suspended ceiling, a hanger(s) attached to the structure shall be required to
ensure that the maximum unsupported length does not exceed 6 ft. (9.2.1.3.3.3).
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
• Comply with obstructed/non-obstructed construction rules for sprinkler head
placement.
• Sprinkler heads spaced closer than 6 ft. apart must be baffled.
• Modifications involving 20 or more sprinkler heads require hydrostatic test and
system isolation if necessary.
• For dry pipe and double interlock pre -action systems in addition to the standard
hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24
hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the
24 hours shall be corrected.
All code references are NFPA 13, 2013 Edition.
Multi—Port Bracke,±_\
FlexHead Sprinkler Drop
Corrugated stainless steel hose with stainless steel braid
available in 2', 3',4',5' & 6' legnths
Adjustable Hub
FLEXHEAD
INDUST 0155
Flexheadbommercial Ceiling Unit
T -Bar Ceiling Installation
Model #2024,2036,2048,2060,2072
PROJECT & BUILDING INFORMATION CONTACT INFORMATION
PROJECT ADOR2SB:
WEETFEILO SOUTHCENTER MALL
181 SOUTHCENTER MALL
SEATTLE, WA 98188
ASSESSOR'S PARCEL HUUSER: 9202474170
LEGAL DESORPTION. WEA SOUTHCENTER LLC SSP PER SNP
REC V01.256809 1-4010CH REALACES
SSP REO VOL 249 PGS 71-8418141 PAR0LL
ATUKWLA SSIP
9110-032 0EC4201010210007E5
TUC- TUKWILA URBAN CENTER
EXISTING OCCUPANCY CLASSIFICATION: M (MERCANTILE)
TYPE OF CONSTRUCTION: 0
PROJECT AREA 9.288 S.F.
TOTAL STORIES: 1
PROJECT STORY: GROUND
FIRE SPRINKLERED
YES- FULLY SPRINRLERED
Project-- SAR!
mocy"5
WESTFIELD SOUTHCENTER MALL
APPLICANT:
TENANT-
ARCHITECT/DESIGNER:
CHINIEY/RECHE ASSOCIATES
1515 MELROSE AVENUE
SUITE 200
SEATTLE. WA 50122
CONTACT: SERGIO CMN -LEY
TEL 2C5918 1501
FAX: 206.915 3449
EMAIL: serg0racnneyn...ram
DING TAI FLING
700 S EI.LEVUE WAY NE F280
BELLEVUE, WA 98004
CONTACT: DAVID WASIELEWSKI
TEL: 208953.0770
mvev s®565m1cu"
CHIN-LEYIRECHE ASSOCIATES
1518 MELROSE AVENUE -
SUITE 200
SEATTLE, WA 98122
CONTACT: SERGIO CHIN -LEY
TEL: 206.939 1501 •
FAX 218.935.3449
EMAIL: eery PQchirieyreche.com
® VICINITY MAP
1"X1"X1/2" TEE
WITH 1/2" PLUG
DRY PENDENT
BARREL
DRILL 1-3/4" HOLE
SEAL W/ 1/2N DEEP
BEAD OF SILIC❑NE
AT TOP
DRY PENDENT HEAD
FOR USE IN ALL FREEZERS
AND COOLER BOXES EXCEPT
PRODUCE & FLORAL COOLERS
1' DROP
TOP PANEL OF COOLER
OR FREEZER BOX (N,ILC.)
DRY PENDENT HEAD
ESCUTCHEON
14' DRY PENDENT MINIMUM
COOLER / FREEZER SPRINKLERS
NO SCALE
TENANT SPRINKLER PLAN
SCALE: 1/8" = 1'-0"
SPRINKLERS
PROJECT TOTALS
SPRINKLER HEAD LEGEND :
SYMBOL
S/N
ORIFICE
NPT
K -FACT.
HEAD
FINISH
PLATE
FINISH
TEMP.
QUAN.
RELIABLE QUICK RESP RECESSED DRY PENDENT F3QR
•
R5714
1 /2"
1/2"
5.6
CHR
CHR
200e
8
RELIABLE QUICK RESP RECESSED PENDENT F1FR56
o
R1414
1/2"
1/2"
5.6
CHR
CHR
155°
105
TOTAL SPRINKLERS = 1 1 3
0 4' 8' 16'
24'
T
GENERAL NOTES
SPRINKLER SYSTEM DESIGN PER }N.F:P.A.#13 - 2010
ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED
ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS
ORDINARY HAZARD OCCUPANCY
130 SF MAX PER SPIRNKLER
1"-11/4" THREADED PIPING TO BE 'DYNA-THREAD'
PROVIDE HANGERS ON 1" ARM -OVERS LONGER THAN 12" (OVER 100 PSI STATIC PRESSURE)
GENERAL LEGEND
—D
—4
BOD
BOB
BOJ
FOS
FOW
EARTHQUAKE BRACING
PIPE HANGER
GROOVED CAP
RIGID COUPLING ( UNLESS NOTED )
'CAP
PLUG
CENTERLINE
HYDRAULIC REFERENCE POINT
CENTERLINE PIPE TO BOTTOM OF DECK
CENTERLINE PIPE TO BOTTOM OF BEAM
CENTERLINE PIPE TO BOTTOM OF JOIST
FACE OF STUD
FACE OF WALL
FOC
AFF
CH
R.C.
cc"
4
F
E/C
c/c
c/E
GG
TG
TxF
ATR
FACE OF CONCRETE
ABOVE FlNISHED FLOOR
CEILING HEIGHT
REDUCING COUPLING
OUTLET COUPLING
WELDED OUTLET
"FIT" FITTING
END TO CENTER
CENTER TO CENTER
CENTER TO END
GROOVE/GROOVE
THREAD/GROOVE (ALSO "GT")
THREAD/"FIT" (ALSO "FxT")
ALL—THREAD ROD
i a,j T� r � ,qq P-- i ;i m �y
L'a:'�JiL-t 2 e.,t DrP R M 1
P;ezDs::;cF2i: 205-575 c 4O7 arld
:;:ve th Fire Pe mit-NO
e
end exact Edi. reSS for shut-
. -;own or on' 1 n approve.
LEGE\D
— — — — — EXISTING SPRINKLER PIPING
NEW SPRINKLER PIPING
�....-EXISTING 1" OUTLET
—e
Q,�-PLUG @ EXISTING 1" OUTLET
---0—
NEW PENDENT SPRINKLER
® NEW DRY PENDENT SPRINKLER
l_I Without Comments
El As Noted in Red
Per The Attached Letter
plans have been reviewed by The Tukwila Fir
r 1 ' r;tinn Bureau for conformance with current Cit,/
.:f:.'..I-?dards. Acceptance is subject to errors and
or.isti,lons which do not ,:-i `':1+Ize violations of adopted
,t-`r:dards and crdiitalic:_:; T"s;r' 1-?sponslbiiity for th
.yr; `u icy offdesion r.:,.,11: ... Rh rhe designer. iter
Ar k ticnS, r_Ieletioil [ : �':Vi j011 I•() .testi drawings G iter
wiil :. '"' ' _-i''.: )ta . C ;t ;[i will rewire a
,'esubrnittai of r .': c:...ir _ _Sib equent app oval,
'=root acceptaoC : is .. • t:., d.: ?:o r1i0 :. _;i and inspect'
The Tukv'Iia
m by
WASHINGTON STATE
CERTIFICATE OF COMPETENCY
FIRE PROTECTION SPRINKLER SYSTEMS
John J. Abel
9780-0691•OG Level 3
Crown Firs Protection, inc.
PAID
•3T 2015
TUKWILA FIRE
,.�‘
CROWN
FIRE PROTECTION
INCORPORATED
P.O. BOX 12113
MILL CREEK, WASHINGTON 98082-0113
PH. (425) 481-7669
DING TAI FUNG
NEW RESTAURANT
WESTFIELD SOUTHCENTER MALL
161 SOUTHCENTER MALL
TUKWILA, WASHINGTON 98188
DATE: 10/ 2016 I DRAWN: C.O. I SCALE: AS NOTED
1 OF 1
•
co
Q1
M
C9
z
z
ca
•
f4
•
2
J
•I
•
i
t
` I
t
•
RE- LocPi E5
t4 — NEW LoGAT io tJ
I
C E 1 L 1 tis
R E r1 a D C
%- 1-0
7
/3 -0 CEl_.1
r
fz
tz-0"c& IL,
14-
14
A L L_
\, rna`n ► r n\� f \ \
•
R HLA- L /1
•
APPROVED
V 4SNi IGTSEASUR 6WARSATH 6 BUREAU
!UN 1 3 1985
AS meeting requirements of this Bureau for classification as spnnklered;
WOW.%'stem changes or additions as recommended on the attached
theet(`*) will result in improved rates. Acceptance applies to plans as
submitted end for construction and occupancy shown thereon. Euaished
lnattllatfnn subject to inspection for final acceptance.
All comments. ,11"l-'" ' anci acceptances relate exclusively to retatm
effect of varnu c^titir ens uaon fere insurance rates They are not ti
be construed a-- L al , in a.ty way upon the question of whether "due
care" has a been to prop with It erecognPized b liability
m:
Injury or damage to property.
result in loss stili exist.
Com,'/,t
TED
WITHOUT COMMENTS.
NOTED IN RED
PER THE ATTACHED LETTER
The drawings affixed he.retohave been
reviewed and accepted by the City of
Tu'.c.tella Fire Dept. A: Haiti- n„ d Ietf bfl5
or revisions to these
'date will t•'.•-....ijt„.m,',-; and will
equine a r s: amitt:S cf revbs.i dr 'Arte,
�-. -pie as ° .:N i =`'r= 1121d,
tai rzp.=,,---ztative cf 11115
''
t _� ,•fir,
-
t
CS T
e
K UJIL:':14
N
J
0
m
2
>-
V)
0
0
z
N
CHECK VALVE
W/ALARM VALVE
W/DELUGE VALVE
CC CC
W W
N V)
_
FL
MOTOR BELL
. z
0
0
t-=
a
W
La▪ i
CC) W
CC
0 17
W M_ N
N < J J
CC C4 La.
1 1 1 1 1 1 1 1
M.rilOeCa�x
DAD
>Z
Z
L)
O z > Q
• �c7
0
03 Q Q U o W
J
oN YW>> iotai ONyV)7=zoOv )
r�z
,MZ U=N Q=
3
IQo
.Qz f 1 j 1 1 1 1 1 1
cn-�®4>—t ZIrr
POST
0
z
W
J
CC
W
c7
Z
$1, — EXPANSION SHELL, ROD &
W
W
C9
W
p
N
- J
0
OD
>-
N
CC
W
J
Y
z_
'a
w
J
F—
J J t Lt 0-
O O ~ - D
0 0 zO
L0 0 .•+
0000w
00Z J
= z = Z W 0 <
c7 w � w a,
IX Z IX • Z >' ? p
Cl- W a w it J
OaOapt�01
1111111
ola®ooV.D
Q
t
r
Superrar Fire Fratedion
i= iii f ti '°i
r
7-1.114111.01
�- K1- - w- -
.-01 -F- IRE DEPARTMENT
ve
'e°ab-44Qnthis l 6'02t7®aoq factafor shit-
wn°rrs°adonapproa/-
i
Kt '--L.oCATIO►_l
N i,
rj
f)
0
d
f
0
REVISIONS
Y
J
u
a
0
It
0
u
w
0
0
C
Sim
4-.
O
c
V