HomeMy WebLinkAboutPP - 81 SOUTHCENTER MALL - BEN BRIDGE JEWELERS INC - PERMITS AND PLANS81 SOUTHCENTER MALL ASSOCIATED PERMITS 18-F-078 08-F-453 18-S-083 08-S-408 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's TaxNo.:C10 t"ti` (7\ Suite NumberIL ) Floor: New Tenant? ❑ - Yes K- No --Vak p� Site Address:\ l�T�l \Q \ t" \Ck Tenant Name:). Y\c\� ,,1 'j�� Property Owner's Name:\ \1-kOat P(E ex Mailing Address:'*Wk. \2) v"ge City State Zip CONTACT PERSON -if there are questions about the submittal. Name: C`Q TCxC�U.\CSV1(�r1 Day Telephone: Z�1 3 tO Company Name: &,U (d'. l'(i ` ?CU‘ri l �A �l5 Mailing Address: Vitk: it\40 J iCrk4 Q ,.f C 3f• n( City State Zip E-mail Address: i 4.i1\C('i10 (� '�C \Ck(�-�?LU�1 . � v/1 Fax Number: U Contractor's City of Tukwila,. 2��'NICET III number: y Business License number: `"L Total number of new/relocated devices or sprinkler heads: l 3 Valuation of Project (contractor's bid price): $2.IUib D Scope of Work (please provide detailed information): AVP, DaCk,Arl\ UV( V(0\14230.“* cdt 6u (l3� div s PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name Th / '€ / Plan Permit App.doc Date: D / 10I2o Day Telephone: .z - 1.0-65-5S460 8/22/14 TFD FP Form 8 issliztv 4ist CITY OF TUICWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION APPS and plans must be complete in order to be accepted fir plan review. "*PLEASE PRINT** SITE LOCATION 1�., King Co. Assessor's Tax No.: Site Address: 8) Soul-hCf� / f IeJ/ Suite Number: Floor Tenant Name: ikn r)4W {i Wej- i✓S New Tenant? ❑ - Yes D- No Property Owner's Name: !A -the,la. i / ti1 9t fl7 ji'7 4r0 u/D Mailing Address: X201 12 OW• 7v/t.w i /Oki City See Tap CONTACT PERSON -if there are questions about the submittal. Name: CI \S 1 1e_ (91\ 0.,111a1/4, Day Tom: 6e1Z6• " / t) 1.7%&G' Company Name: CrOt.Vrl J riff7rc f -e -t io17 t 1)1 G Mailing Address: PO Box 12-413 m ; 1l Crie.k , WA- /W d Z CityState Trp E-mail Address: %1 636. aLc.Yow lel{ f • Co Y» Fax Number Contractoes fay Tukwila NICET III number:q,� tO • (�S I 1 • ( 6 License number. $V 5 • Q 5oV2 Total number of new/relocated devices or sprirrlder heads: y 2 Valuation of Project (contractor's bid price): $r4 . Scope of Work (please peovide detailed information): rex-Ire (zt ltleadks e Pad Up) )4C.Ads PERMIT APPLICATION NOTES Value of Censinetis . — In all cases, a value of uanstrudian arrtioanE should be entered by the applicant. This fugue will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on die site authorized by such permit is c ommeaoed wiohie 110 dans ager its isaimce,a lithe work authorized on the site by such pant is suspended or abandoned for a period of 110 {lays atter the time the work is commenced. The Fire Marshal is authorized horized to grant, in writing, one or more extensions of time, For periods not more than 130 days each The extension shall be requested in writing and justifiable erne demd. I HEREBY CERTIFY THAT I HAVE READ 21,NID EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON; AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O OR AUTHORIZED AGENT: Signature- Ol L Print Name: rkSS/C .ihjn � 7 Plan Permit App_doc 822/14 Date:*1618' DarT: 6125 d'itt.174CA. • TFDFPFont' 8' $ FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Ben Bridge Jewelers 81 Southcenter Mall Permit No.: 18-S-083 Date: April 24, 2018 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods Tess than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and (located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. V FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Ben Bridge Jewelers 81 Southcenter Mall Permit No.: 08-S-408 Date: Aug 8, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • These conditions apply to any sprinkler piping exposed as necessary to accomplish the permitted scope of work. All references are NFPA 13, 2007 Edition. 1 1 1 1 1 1 1 1 1, I-8" 4 3/8" SIM 6'-10" PL3 14'-11" A F F 1-6� 19'-10" I I CL OF BATTENS j 1, 24" jI X l;-6" SECURITY URTAIN TRACK 5o 0 CV 00 9N PL3 10'-0" A F F • LT J _ _ _ WC1 12-2"AFF —CENTER LIGHT ABOVE CASEWORK BELOW PERFORATED PANEL METAL PANELS AT CEILING PROVIDE 1/8' JOINT BETWEEN PANELS TYP PAII1T BLACK LINEAR MECH DIFFUSER ADJACENT ' TO WQ BATTENS `a4°• r M mak° GWB (P-1)‘ 10'-6"AFF. CV • 00 4 W REF TO ELEC FOR LIGHTING LAYOUT WALL ABOVE LINEAR SLOT DIFFUSER ALIGN W/ SEAM AT ZINC w PANELS TYP a-4, w �- 2'-0", -' 2'-0" 14'-4 1/2" z - \ LINEAR SLOT DIFFUSER ALIGN W/ SEAM AT ZINC PANEL TYP GWB P-1 10'-6" A F F o LEASELIN -,r� SCB LINE OR WALL ABOVE; L I ! - - 2'-1 ` 2'-_0" < 2'-0" 2'-1' " 4" FROM EDGE Of CASEWORK BEL1JW, TYP GWB (P-1) -• -- 6'-1-1/2" `• 9',6"AFF, - `l0'-0" -, • - , EQ 4'-111/2" 1'-81/4" 2'-71/2" 2'-21/4" 3'-8 1/4" 8'-01/4" 6" EQ EQ 4'-7" 24'-0" 24'-0" 7'-10" REFLECTED CEILING PLAN 1/4" =1'-0" Design per NFPA 13 — Ordinary Hazard All materials to be new, U L listed and F M approved All heads to be at least 6' apart with no obstructions • 36 — Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 • 6 — Add Reliable Model G5-56 Quick Response 165° Concealed Pendents % x 1/2 WC1 9'-0"AFF _ MTL3 10'-0" A F F CL C I" 11111116 `%I%%;` :.Corrugated stainless steel hose with available in 2', stainless steel brae gnths FlexHead Sprinkler Drop r Multi -port Bracket Adjustable Hub ,LEXJ�j�q� INDUS i"IES l Ci 'f4ex head'ommercial Ceiling Unit T -Bar Ceiling installation Model #2024,2036,2048,2060,2072 111 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS 111 TOP BEAM/ C—CLAMP WITH SET SCREW PIPE SWIVEL RING .11111 3/8' ALL THREAD ROD 0i STEEL JOIST/TRUSS HANGER DETAIL NTS ACC O Without Comments O As Notedn Red 15r Per The Attached Letter These plans have been reviewed by Tne Tukwila Fire Prevention Bureau for conformance v.,tri current Clty sta1Cards. Acceptance is slabiec* ro errors and omissions whle co rot autr=or'ze 0l03tirrts of adopted s � I''.a, ds aan`.l cit: nanzes Tne res ,uPS'!tisty cor the adequacy of des'g" rrsr-s totally w'rti trfe designer. Add (ions Ge'eaol,s r - (I'ylSicrS to rrese dir3 trgs after this crate v.l.l vad t . _-ep:ance a-,0 "r .i ra,,:, re a resiJo+rnit'.ai of r�vis C ' 1;1f+#'CJS fo- SJCseorent ac,pr''✓vat Final a�ceprance s .GJect to fleia test a,na lnspec:lo i L The Tukwiia F:: e :."i.onn 6u-cau. Date (/-19� By: ;UKWILA r r D ZP RT I .NT .eazv c;..'I 2-.:1:-'_:75-4407 and i'2,lS:1-NV J id exact. z7 F , n cr rczto atIon apprcv2!. r • �► R��� Pm/ UIR r John J Abel r 1 C�80-0591-C•� I RrWhl �r - . LL les aaaaaarraaaaaaaaa 17l1i aa�aaamaai • CROWN FIRE PROTECTION INCORPORATED P 0 BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Ben Bridge jewelers 81 Southcenter Mall Tukwila, WA 98188 DATE t -/ 7 • r I DRAWN a ate. I SCALE , { �/ I PAID AP? > ;i zii5 .3 y36, y SHEET \UM3ESHEET TITLE BRID R s FA -01 SYSTEM I\ EO vlATI O N FA -02 TYPICAL WRING A\D IvOUNTING DETAILS FA -03 SYSTEV CALC U LATI O \S AND SI\ OLE LINE DIAGRAM FA -0L FI ALAN SYSTEV PLA\ SHEET INDEX ( Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revisit -6 urawings for subsequent approval. Final acceptance is subject to held test and inspection by The Tukwila Fire Prevention Bureau. Date: Lj , o -1$ By: 5-1 1 . KWILA FIRE DEPARTMENT 2C,_3-: 75-4 :-O7 and z'u thk; 3 irc Permit No. IB-FB a,f- ri!: s for shut- �_ �fm cr re.Yzrei±on ppprova1 WISE SCHEDULE A\D CO SUIT FILL CHAT SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END TE SH WEL ,_.JRS DDITI ON FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 2 4 3 2 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 3 FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S BOX CEILING �.{ FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DETECTOR FDBZ492-HR IN/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD END-OF-LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND J j • �I J BEN BRIDGE JEWELERS 81 /SPACE #740 1.• W42 .•. aa,�..crw macys I MUMS F REIM_ ez RED. I w ` I •rr .53:113144 w J WIRE DESIGNATION GENERAL NOTES SITE PLAN PAID O f� R 1 0 i 6=.f `.e p, S :: !JKW!I A. FIRS - Cc- V13c(e uy Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved o crco_ r` WZ O wC*r6 Woa.z $ O WJO _D w < z W �s op C.' v,w< 0 c! z _ <w Z CC w `LOi CO co CALE: NOT TO SCALL DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/02/18 BACKROUND PLAN PROVIDED BY: .OB NUMBER: 3172-1} SHEET V\ WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER DF CONDUCTORS SIZE TYPE COLOR CODE C D P S S' V V' I STROBE SYNC DATA LINE -ADDRESSABLE LOOP DEVICE POWER - 24VDC STROBE CIRCUIT - FEED STROBE CIRCUIT - RETURN SPEAKER CIRCUIT - FEED SPEAKER CIRCUIT - RETURN REMOTE INDICATION LIGHT TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) TWO #16 FPL/FPLR RED (JACKET) TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR #14 FPL/FPLR RED (JACKET) TWISTED PAIR #14 FPL/FPLR RED (JACKET) TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END TE SH WEL ,_.JRS DDITI ON FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 2 4 3 2 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 3 FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S BOX CEILING �.{ FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DETECTOR FDBZ492-HR IN/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD END-OF-LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND J j • �I J BEN BRIDGE JEWELERS 81 /SPACE #740 1.• W42 .•. aa,�..crw macys I MUMS F REIM_ ez RED. I w ` I •rr .53:113144 w J WIRE DESIGNATION GENERAL NOTES SITE PLAN PAID O f� R 1 0 i 6=.f `.e p, S :: !JKW!I A. FIRS - Cc- V13c(e uy Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved o crco_ r` WZ O wC*r6 Woa.z $ O WJO _D w < z W �s op C.' v,w< 0 c! z _ <w Z CC w `LOi CO co CALE: NOT TO SCALL DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/02/18 BACKROUND PLAN PROVIDED BY: .OB NUMBER: 3172-1} SHEET V\ THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NEPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ DEDICATED O.1ERGENCY TUBE OUTLET--. SAMPLING TUBE INLET—. SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE FCR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC ISrATE FFRRL[1MSGRUUNND1GD TO NEXT ADDRESSABLE (-I- DEVICE +DEVICE STOP IF LAST DEVICE raw XLS CONTROL PANEL (+ DR PREVIOUS ADDRESSABLE DEVICE — O° L�1 � r cR0l1 &I L 4 J 0 HTRI-R 0 Je 06 0 NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C—CABLE C—CABLE GRD N L ©Qco PAD -3 00 INPUT INPUT TROUBLE NACI NAC2 NAC3 NAC4 AUX +1— 1 2+2— 2 NC C NO + — + — + — + — + — 0 (-) (+) 2 NAC 4 CIRCUIT NAC 3 CIRCUIT NAC 2 CIRCUIT (-) CEILIN TILE SUPPORT BRIDGE 4L SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4° SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE 0 (+) FROM XLS CONTROL PANEL OR E`+ PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH _L oeT GROUND 0 0 0 0 HTRI-R OSTATUS LED Co 0 N.O. 0 CD 0 N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 MUSIC HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL LAC POWER SOURCE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32' F 0' C TO 100' F 36 C) HUMIDITY: —9 % RELATIVE HUMIDITY, NON—CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) >— Sl DATA IN (+) > TO NEXT DEVICE OR END OF LINE DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION 11TH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD r SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL > TO NEXT ADDRESSABLE DEVICE TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE TB1 C 90 1) NO COM NC EOLR 470 SWITCH INPUT 19 0 + - LED TSM -1 0 00 TO FAN SHUTDOWN TO NEXT e ADDRESSABLE DEVICE ° 0 .I1 -6) 2 00 HTRI-R 0 NO COM 6) NC ® • TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTI❑N BOX—, MOUNTED ON \� CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT O O TO NEXT DEVICE --CADDY BAR 0 0 I SMOKE DETECTOR -- SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Co I -r) co AVE. SO., SEATTLE, VVASHINGTON cv 0 c\I I I J RELEASE/REVISIONS REV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 04/02/18 2 aaK ‹ v,�of} _J'4:7( I�— L�I00Cs �C SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/02/ 18 BACKROUND PLAN PROVIDED BY: .JOB NUMBER:31725-1} SHEET F' --O2 yy ht 2013 by Guardian Security Systems, Inc. All Rights Reserved —� A B C D E F G H J K FIRE ALARM BOOSTER Project: BEN BRIDGE JEWELERS Panel: EXISTING PAD -3 REMOTE Date: April 2, 2018 Module/Device POWER T.I. BOOSTER Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 2470 Total(A)= 15 Total(B)= 2610 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 2610 Total current ratings concerted to amperes (line D x .001) 0.015 2.61 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 0 Multiply lines E and F Total Standby AH 0.36 0.0023 Alarm sounding period in hours (5 mins+ .0833 hours) ««< 0.0833 Multiply lines E and H Total Alarm AH 0.0635 0.217413 Add lines G and I Total Standby and Alarm AH 0.577413 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.6928956 0.009600 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: BEN BRIDGE JEWELERS T.I. Panel: EXISTING PAD -3 REMOTE BOOSTER POWER SUPPLY Wire Resistance 2.58 Date: April 2, 2018 CURRENT TOTAL= 2470.00 ZH-MC-CW @l5cd 87 ZH-MC-CW @30cd 131 ZH-MC-CW @75cd 222 ZH-MC-CW @95cd 292 ZR -MC -W @15cd 64 ZR -MC -CW @l5cd 69 DEVICES MAXIMUM LOAD TOTAL mA=' Total Wire Resistance (R ) Total Device Load, Amps (1) : Voltage Drop ( E ) EOL Voltage 0 0 0 0 0 0 1500 14 24.00 1500 (WL*2)*(R/ft) 0.00 (Total Cct Load) 1.50 (E=I*R) 0.00 24 - E) 24.00 ZH-MC-CW @l5cd ZH-MC-CW @30cd 1 ZH-MC-CW @75cd 1 ZH-MC-CW @95cd 3 ZR -MC -W @15cd 1 ZR -MC -CW @95cd DEVICES 6 87. 131 222 222 2.92 292 64 192 264 264 TOTAL m A= 970 14 267 0 Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 22.66 970 (WL*2)*(Rift) (Total Cct Load) (E_I*R) 24 - E) 1.38 0.97 1.34 22.66 CALCULATIONS BEN BRIDGE JE , E ERST.1: FACP: ADD-QiS DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: co N Device Type Qty Amps Total Amps Total NFP -11 0 0.0022 0.0022 0.0023 0.000 ««< FDBZ492-HR 2 0.0635 0.0635 0.064 0.128 HTRI MODULE 3 0.009600 0.0096 0.021 0.063 0.0731 Amps 0.191 Amps S S2-1 S2-2 S2-3 S2-4 S2-5 S2-6 15Cd 75Cd 15Cd 15Cd 95Cd 95Cd D,I 21 SINGLE LINE DIAGRAM D,I IHT-R1 21 TSM EOL S3 Pro FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. t J V) O� 013 N '0 .0 N AVE. SO., SEATTLE, WASHINGTON r- o (_) (v rr) RELEASE/REVISIONS m uJ DMG DESCRIPTION SHOP DRAWINGS DATE co N 0 Nt 0 ««< CC 0 uJ cie) W co W _ jpr LLJ 5.O v°') O W2 J0 w <z ctd LLI LU EE 110 CO 00 0 LLf CO SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/02/1 8 BACKROUND PLAN PROVIDED BY: .0B NUMBER:31725-1 SHEET FA -03 rietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 8'-5 1/2" 6'-1" 13-9 1/2" 7 FLOOR STRIKES SPACED @ 8'-5 1/2=50-10 1/8" 11 1/2" 3 3/4" S2-3 15Cd RESTROOM!' 106 71- PTDNVR CN 1 HT—R1 rc L— • STOCK ' 105 S2-2 75Cd t I 1: 5'-0" 10 IT CLOSE 104 D / CN 1-5" - 1-6 2 3/8" 1-' 1--t' •'•• . SALES b' FLOOR 4 102 t -6" REF DISH P3 HT—R T 7,-0!, BRIJ:WT.7r, AREA' 41-7" 107 S2-1 15Gd TO EXISTING TENANT JUNCTION BOX r 8'-9 3/4" t. r 7'-0" 19'-0" ri) to \ 4"MAX 5 FLOOR STRIKES SPACED @ 8'-6 5/8"=34'-2 1/2" ROLEX 103 +/-4'-5"V1F EQ j, EQ 10 4'-5 1/2" 8-10 1/4" 6'-11 3/4" 6-4 7/16" 6'-3 5/16" 6'-4 7/16" 60-1 1/2" 24'-0" 24'-0" 7'-10" f 10 FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 4,101, 400.0t0 11; tr, 41 116,, RELEASE/REVISIONS IREV. BY: I . m 0 DESCRIPTION SHOP DRAWINGS LL, E- < 04/02/18 2 <<<<< (S-CALE: 1 / 4" = 1 '0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/02/1 8 BACKROUND PLAN PROVIDED BY: .1_0Ei NUMBER: 31 725— 1} r SHEET FA -04 Proprietary and Confidential, CouLght 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET I\ FILE CO UVIHESHEET TITLE SHEET INDEX BEN BRIDGE FIRE ALARM SYS EM TUKWILA, WASHINGTN FA -01 SYSTEM I\FOMATION FA -02 TYPICAL DETAILS - WRING AND MOUNTING FA -03 FRE ALARM SYSTEM FLOO PLAN FA -04 SYSTEM CALCULATIONS (GENEAL), SITE PLAN n A EPTE Without Comments As Noted In Red Per The Attached Letter nese plans have been reviewed by The Tukwila Fire Prevention Bureau for confol roar,oc with current city standards. Acceptance . _ .,. a to ellcrs and omissions which do not _:st,tiloriL vi _,I;:tions of adopted star,aara, _crd oKlIn: zcc3 TI':., ;:. cr i iy for the adegil '� o ..,: i::)n tr,:it ii I. r :. ta"signer. Additions, i.:i,'i:: i:: C)! i'i:'v ^; i. ^ - ;l i+_ :': draawings atter this da: :i. v ;.h accepi_Yr,r:_ ,.-d r:al require a resubmittal of revised arawings to subsequent approval. Final accepi:ance is subject to field test and inspection b\ The Tukwila Fire Prevention Bureau. G3 Date: / - kr- Og By: 3/ I UKWILA FIRE DEPART:a I Please call: 575-4407 and give this job No. GE- F - and exact address for shut, awn or restoration approval vmmacr .,-Morsvwamer' M NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED 1418 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED SYMBOLS LEGEND QUANTITY 2 1 6 1 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD 0 DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD ISN LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT SMOKE p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING LJC FIRE ALARM SPEAKER STROBE (CEILING MOUNT) ZH-MC---CW SIEMENS 4S DEEP BOX CEILING c FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM STROBE (CEILING MOUNT) ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING L FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.0.N. pc FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. B WP FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX w/ 1 -1 /2" EXT. 80" A.F.F. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.D. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.❑, FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.D.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAID SEP - a 2008 Tukwila Fire Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NYI DESCRIPTION SHOP DRAWINGS DATE 03 0 0 03 2 CCCaC -% l/ Z cc 0 0 z c0 CO J 00) LII W 0 W~ C z Cr 2w. m �=a Z < =� CO 1- W (1) SCALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 8/01/08 BACKROUND PLAN PROVIDED BY: \OB NUMBER: SHEET FA -01 , THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC 0 DUCT DETECTOR LOCATI❑N 1 � END OF LINE DEVICE(3.6K 1/4W) .T e SUPERVISED SWITCH GROUND r-) -4- 0 HTRI—R OSTATUS LED 00 0 N.0 0 COM c0 0 N,C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL 0 LABEL SSE (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 11 VOLTAGE MAX. - CURRENT MAX. - CONT. RES, MAX, - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - OUTLET SAMPLING--\\ TUBE INLET SAMPLING--•\ TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING 0 TO NEXT ADDRESSABLE DEVICE f STOP IF LAST DEVICE 1(-) FROM XLS CONTROL PANEL OR PREVI❑US ADDRESSABLE DEVICE (-) RELAY CONTACTS (4,0A @ 125VAC) (4,OA @ 30VDC) 27 VDC 3,5 nA DURING POLLING 10 OHMS 200 FT, (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. 0 + 100I TB1 SSmoo0 123456 HCP TB2 0 0 +- 654321 END OF LINE 1 DEVICE 7 (3.6K 1/4W) SUPERVISED SWITCH % GROUND -0 0 0 tip HTRI—D OSTATUS LED CO 0 NOT USED 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC 0 PAD -3 0 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 Lel 61_Q. 0 24K n + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END OF LINE DEVICE 3.6K 1/4W) \SUPERVISED SWITCH NAC -4 NAC -3 Z NAC -2 NAC -1 FRONT VIEW / I NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP .L 0. 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS 4W EOL TS M-1 0 • -1-2345 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCA1E NONE 0 0 EARTH GROUND -3.4+)TO NEXT DEVICE OR >t-) STOP IF LAST DEVICE HORN STROBE / STROBE WIRING DIAGRAM LABEL SCALE SPEAKER STROBE OR STROBE ONLY R 1 0 HORN/STROBE 4S DEEP BOX IN/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE EEL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER 11N TEMPERATU +32'F 0'C TO 100F (3E: 311C) HUMIDITY: 9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > - DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT IN WHEN USED IN CONJUNCTION WIN DUCT HOUSINGS AD -11P OR AD-11XPR r— D8-11 ' STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE > ( ) DATA OUT (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID -\ CEILING SPEAKER SUPPORT TILE BRIDGE HARD LID -\ 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALElONE JUNCTI❑N BOX—, MOUNTED ON \ CEILINGI FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT / / / / // 0 0 0 0 f 1 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 1 CALE: 1 /8"= 1 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 8/01 /08 BACKROUND PLAN PROVIDED BY: ,0B NUMBER: SHEET FA -02 75 o— 2S 75 y o-- 2S q 2S 2S FA -BOX 2 w� 75 a— 2S IJ c -75 15 o— 2S y 75 C o— 2S EOL—S1 NORTH BEN BRIDGE \NESTFIELD SOUTHCENTER MALL SCALE 1l8" -V FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITSXSEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z Q DESCRIPTION SHOP DRAWINGS DATE 1 8/01/08 2 aaCCa J co co T JOf? W �� Q �r W 0 Lw - F CC MWCO oo 3 < Z ct � Lk � e:)s meg. °° ..CALE: 1 /8"=1 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 8/01 /08 BACKROUND PLAN PROVIDED BY: \0B NUMBER: C SHEET k FA -03 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved I I I OR RO \ / (Th .•••• • • I i--- L. V 171, fl7! ' CANOPY ° 11 ffi ELEC ELEC PARFUMFRIE SUNCOAST TI ON PICTURE WA LD N IR 00k. S NORTH BIAGIO VERIZON T Li Li 02 < Lu PUB' IC CORR. [LEG I7 -1 -v -T CASUAL CORNER R. II< II I I—• 0 LJ WIRELESS SYSTEM CALCULATIONS •g, Z(I) 00 ch - 0 ELEC BATTERY SIZING CALCULATION MADE IN WASHINGTON SPENCER GIFTS BEN BRIDGE WESTFIELD SOUTHCENTER MALL N4ALL MALL OFFICE OFFICE TZ nL. SCALE NTS 2S 75 C 15 2S 2S 2S 2S 2S 30 C 75 C 75 C 75 C 75 EOL—S1 2S FA—BOX EX FACP 0 21 Notification Appliance Circuit Detail PROJECT: !WESTFIELD SOUTHCENTER MALL Panel: BEN BRIDGE Date: September 8, 2008 CIRCUIT: S1 QTY Device Type !Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 0 :ZH-MC @1 5CD 1 !ZH-IVIC @30CD 142 142 5 iZH-41.11C ©75CD 219 1095 i I 1 I i 1 I I Wire Resistance 1.62 CURRENT TOTAL= 1301 108 0! Total Wire Resistance ( R ) 0.65 ( WL * 2 )* (R/ft) Total Device Load, Amps (I) 1.301 (Total Cct Load) Voltage Drop ( E) 0 0 (E= I * R) 0 . _ 0 1 Z-MC@l5CD 64' 64 0 'Z-MC@30CD 98 0 DEVICES= 7 TOTAL mA=1 1301 EOL Voltage 19.55 (20.4 - E) 11 12 202 19.54852152 1301 1 FAX (206) 628-4.990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: BEN BRIDGE BEN BRIDGE FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS DATE 8/01/08 2 <<<<IC Current Load: Standby: Alarm: Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 AD2-P 1 0.0635 0.0635 0.064 0.064 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R HTRI-D ICP -B6 2 0.009600 0.0096 0.021 0.042 ZH-MC-CW@15CD ZH-MC-CW ©30CD 0.108 0.001600 0.0035 1 0.142 0.142 0.005 ZH-MC-CW ©75CD 5 0.219 1.095 ZR -MC @15CD 0.0731 Amps 0.106 Amps 0.445 1 0.064 0.064 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 0.098 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.03 Amps 1.331 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.331 Amps For 5 Minutes= 0.112 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 1.040 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 1.040 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION MADE IN WASHINGTON SPENCER GIFTS BEN BRIDGE WESTFIELD SOUTHCENTER MALL N4ALL MALL OFFICE OFFICE TZ nL. SCALE NTS 2S 75 C 15 2S 2S 2S 2S 2S 30 C 75 C 75 C 75 C 75 EOL—S1 2S FA—BOX EX FACP 0 21 Notification Appliance Circuit Detail PROJECT: !WESTFIELD SOUTHCENTER MALL Panel: BEN BRIDGE Date: September 8, 2008 CIRCUIT: S1 QTY Device Type !Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 0 :ZH-MC @1 5CD 1 !ZH-IVIC @30CD 142 142 5 iZH-41.11C ©75CD 219 1095 i I 1 I i 1 I I Wire Resistance 1.62 CURRENT TOTAL= 1301 108 0! Total Wire Resistance ( R ) 0.65 ( WL * 2 )* (R/ft) Total Device Load, Amps (I) 1.301 (Total Cct Load) Voltage Drop ( E) 0 0 (E= I * R) 0 . _ 0 1 Z-MC@l5CD 64' 64 0 'Z-MC@30CD 98 0 DEVICES= 7 TOTAL mA=1 1301 EOL Voltage 19.55 (20.4 - E) 11 12 202 19.54852152 1301 1 FAX (206) 628-4.990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NVI DESCRIPTION SHOP DRAWINGS DATE 8/01/08 2 <<<<IC LU LU coQ 03 w <z < 0 0 CC LLI '-iZ Z CC 2 6= w co cd -cc ow 0 _3 I< Z < LLI LU 15 CO u.-fc- cl) 0 c73.0 (f) 'CALE: 1 /8" = 1 DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE: 8/01 /08 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ,JOB NUMBER: SHEET \_ FA -04_ 1 GENERAL NOTES: ESTERN STATES AREA OF WORK 1. Western States Fire Protection to relocate pendent sprinklers due to new walls and ceilings added for tenant improvement. 2. Sprinklers shall be spaced in accordance with NFPA #13 Ordinary Group II Occupancy with 15'-0" maximum distance between sprinklers and a maximum coverage of 130sq. ft. 3. The building qualifies as non obstructed construction. 4. All hanger assemblies shall be spaced and installed in accordance with NFPA and manufacturer's specifications. 5. Branchline and arm over is black Schedule 40 pipe. 6. Ali new=threaded fittings to be ductile iron. 7. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 8. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 9. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in areas of work. All other areas are not in contract and WSFP in not responsible for existing conditions. PIPE LEG_ENC EXISTING PIPE NEW PIPE SYMBOL LEGEND VICINITY MAP NOT TO SCALE REVISIONS I�OKM SPRINKLER LEGEND • • 1 ,N m -WO RKROON 1u1� 11111111 111S® •. o R Atir ii♦L�� flu, C i a 11 ri 1 ' 1 1•0 1'1-quernir- Nommi.v. Rue il O O R O Ro 0 11) O altaRK,RO R R 9••-A / 0 0 0 4 - 9'47 N 41.11Nt \ Ns\ kla \i NEW NEW ADDED RETAIL SECTION SALES AREA N7411.7 Ro E4 O 9'4; 12' O 9•-P VP' 9' -CI' E RIDGEJEWE RS SCALE: 1/4" = 1'-0 4' 2' 0 2' 4' 8' SPRINKLER LEGEND APPROVAL: CITY OF TUKWILA 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYMBOL DESCRIPTION ORIF. FINISH OUANTRY SYMBOL DESCRIPTION ORF. TEMP FINISH QUANTITY 4 -WAY EARTHQUAKE BRACE EXISTING SSP 1/2" 5.6 155° CHROME 26 CONT. NO.: N/A HYDRAULIC REFERENCE POINT R RELOCATE TO REL G4A CONCEALED 1/2" 5.6 165° WHITE 13 DRAWN BY: C. Isaac HANGER SYMBOL OR OP RELOCATE EXISTING SSP 112" 5.6 155° CHROME 7 SPRK. ON SHEET: 50 PLUG EXISTING SSP 1/2" 5.6 155° CHROME SPRK. ON JOB: 24 DATE: 08/06/08 HANGER DETAIL NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt II. / ` , , A- / / .,.y Rod Coupling —` Concrete Construction d Cut Rod Lgth All Thread — Rod CL Bottom of Concrete to -`s Rounded to NearestY2' Rounded to 3/8" All Thread – Rod ~q. 1111111 Center Line of Pipe Nearest Inch Swivel Ring �, ,._A Pipe Note on Plan Center Line of Pipe Note on Plan: Hanger Number Swivel Ring and 'A' Dimension HANGER DETAIL NOT TO SCALE FILE COPY HANGER DETAIL NOT TO SCALE TYPICAL FLEXABLE SPRINKLER CONNECTION: u PIPE NIPPLE w w. • SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID CEILING TILE Western States Fire Protection Company 7102180th AVE NE, STE A-105 - REDMOND, WA- 98052 Lie. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE IAUSTIN I DALLAS/ DECATUR / DENVER !DULUTH /HOUSTON ! KANSAS CITY LAS VEGAS/MINNEAPOLIS / PHOENIX ! PORTLAND /RAPID CITY/ ST. PAUL/SALT LAKE CITY/SEATTLE Phone:425-881-0100 Fax:425-881-3030 SPRINKLER HEAD FLEXHEAD DETAIL NOT TO SCALE BEN BRIDGE JEWELERS UNIT #740 -2477 SOUTH CENTER PKWY TUKWILA, WASHINGTON pA (j[ -7 2008 CONTRACTOR I Tukwila Fire te-5' 477/ a Hanger No. 05C Concrete Anchor HILTI 3/8" HDI -P L. k/ / 5/ Hilti 3/8" HDI -P / / \,:" (Dri led) /� ` / % / -`s Rounded to NearestY2' 3/4" 3/8" All Thread – Rod ~q. 1111111 j Concrete Construction Bottom of Concrete to Center Line of Pipe Swivel Ring Pipe Note on Plan: Hanger Number and 'A' Dimension FILE COPY HANGER DETAIL NOT TO SCALE TYPICAL FLEXABLE SPRINKLER CONNECTION: u PIPE NIPPLE w w. • SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID CEILING TILE Western States Fire Protection Company 7102180th AVE NE, STE A-105 - REDMOND, WA- 98052 Lie. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE IAUSTIN I DALLAS/ DECATUR / DENVER !DULUTH /HOUSTON ! KANSAS CITY LAS VEGAS/MINNEAPOLIS / PHOENIX ! PORTLAND /RAPID CITY/ ST. PAUL/SALT LAKE CITY/SEATTLE Phone:425-881-0100 Fax:425-881-3030 SPRINKLER HEAD FLEXHEAD DETAIL NOT TO SCALE BEN BRIDGE JEWELERS UNIT #740 -2477 SOUTH CENTER PKWY TUKWILA, WASHINGTON pA (j[ -7 2008 CONTRACTOR I Tukwila Fire te-5' 477/ a 81 SOUTHCENTER MALL ASSOCIATED PERMITS 18-F-078 08-F-453 18-S-083 08-S-408 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's TaxNo.:C10 t"ti` (7\ Suite NumberIL ) Floor: New Tenant? ❑ - Yes K- No --Vak p� Site Address:\ l�T�l \Q \ t" \Ck Tenant Name:). Y\c\� ,,1 'j�� Property Owner's Name:\ \1-kOat P(E ex Mailing Address:'*Wk. \2) v"ge City State Zip CONTACT PERSON -if there are questions about the submittal. Name: C`Q TCxC�U.\CSV1(�r1 Day Telephone: Z�1 3 tO Company Name: &,U (d'. l'(i ` ?CU‘ri l �A �l5 Mailing Address: Vitk: it\40 J iCrk4 Q ,.f C 3f• n( City State Zip E-mail Address: i 4.i1\C('i10 (� '�C \Ck(�-�?LU�1 . � v/1 Fax Number: U Contractor's City of Tukwila,. 2��'NICET III number: y Business License number: `"L Total number of new/relocated devices or sprinkler heads: l 3 Valuation of Project (contractor's bid price): $2.IUib D Scope of Work (please provide detailed information): AVP, DaCk,Arl\ UV( V(0\14230.“* cdt 6u (l3� div s PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name Th / '€ / Plan Permit App.doc Date: D / 10I2o Day Telephone: .z - 1.0-65-5S460 8/22/14 TFD FP Form 8 issliztv 4ist CITY OF TUICWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION APPS and plans must be complete in order to be accepted fir plan review. "*PLEASE PRINT** SITE LOCATION 1�., King Co. Assessor's Tax No.: Site Address: 8) Soul-hCf� / f IeJ/ Suite Number: Floor Tenant Name: ikn r)4W {i Wej- i✓S New Tenant? ❑ - Yes D- No Property Owner's Name: !A -the,la. i / ti1 9t fl7 ji'7 4r0 u/D Mailing Address: X201 12 OW• 7v/t.w i /Oki City See Tap CONTACT PERSON -if there are questions about the submittal. Name: CI \S 1 1e_ (91\ 0.,111a1/4, Day Tom: 6e1Z6• " / t) 1.7%&G' Company Name: CrOt.Vrl J riff7rc f -e -t io17 t 1)1 G Mailing Address: PO Box 12-413 m ; 1l Crie.k , WA- /W d Z CityState Trp E-mail Address: %1 636. aLc.Yow lel{ f • Co Y» Fax Number Contractoes fay Tukwila NICET III number:q,� tO • (�S I 1 • ( 6 License number. $V 5 • Q 5oV2 Total number of new/relocated devices or sprirrlder heads: y 2 Valuation of Project (contractor's bid price): $r4 . Scope of Work (please peovide detailed information): rex-Ire (zt ltleadks e Pad Up) )4C.Ads PERMIT APPLICATION NOTES Value of Censinetis . — In all cases, a value of uanstrudian arrtioanE should be entered by the applicant. This fugue will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on die site authorized by such permit is c ommeaoed wiohie 110 dans ager its isaimce,a lithe work authorized on the site by such pant is suspended or abandoned for a period of 110 {lays atter the time the work is commenced. The Fire Marshal is authorized horized to grant, in writing, one or more extensions of time, For periods not more than 130 days each The extension shall be requested in writing and justifiable erne demd. I HEREBY CERTIFY THAT I HAVE READ 21,NID EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON; AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O OR AUTHORIZED AGENT: Signature- Ol L Print Name: rkSS/C .ihjn � 7 Plan Permit App_doc 822/14 Date:*1618' DarT: 6125 d'itt.174CA. • TFDFPFont' 8' $ FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Ben Bridge Jewelers 81 Southcenter Mall Permit No.: 18-S-083 Date: April 24, 2018 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods Tess than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and (located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. V FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Ben Bridge Jewelers 81 Southcenter Mall Permit No.: 08-S-408 Date: Aug 8, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • These conditions apply to any sprinkler piping exposed as necessary to accomplish the permitted scope of work. All references are NFPA 13, 2007 Edition. 1 1 1 1 1 1 1 1 1, I-8" 4 3/8" SIM 6'-10" PL3 14'-11" A F F 1-6� 19'-10" I I CL OF BATTENS j 1, 24" jI X l;-6" SECURITY URTAIN TRACK 5o 0 CV 00 9N PL3 10'-0" A F F • LT J _ _ _ WC1 12-2"AFF —CENTER LIGHT ABOVE CASEWORK BELOW PERFORATED PANEL METAL PANELS AT CEILING PROVIDE 1/8' JOINT BETWEEN PANELS TYP PAII1T BLACK LINEAR MECH DIFFUSER ADJACENT ' TO WQ BATTENS `a4°• r M mak° GWB (P-1)‘ 10'-6"AFF. CV • 00 4 W REF TO ELEC FOR LIGHTING LAYOUT WALL ABOVE LINEAR SLOT DIFFUSER ALIGN W/ SEAM AT ZINC w PANELS TYP a-4, w �- 2'-0", -' 2'-0" 14'-4 1/2" z - \ LINEAR SLOT DIFFUSER ALIGN W/ SEAM AT ZINC PANEL TYP GWB P-1 10'-6" A F F o LEASELIN -,r� SCB LINE OR WALL ABOVE; L I ! - - 2'-1 ` 2'-_0" < 2'-0" 2'-1' " 4" FROM EDGE Of CASEWORK BEL1JW, TYP GWB (P-1) -• -- 6'-1-1/2" `• 9',6"AFF, - `l0'-0" -, • - , EQ 4'-111/2" 1'-81/4" 2'-71/2" 2'-21/4" 3'-8 1/4" 8'-01/4" 6" EQ EQ 4'-7" 24'-0" 24'-0" 7'-10" REFLECTED CEILING PLAN 1/4" =1'-0" Design per NFPA 13 — Ordinary Hazard All materials to be new, U L listed and F M approved All heads to be at least 6' apart with no obstructions • 36 — Relocate Reliable Model G5-56 Quick Response 165° Concealed Pendents 1/2 x 1/2 • 6 — Add Reliable Model G5-56 Quick Response 165° Concealed Pendents % x 1/2 WC1 9'-0"AFF _ MTL3 10'-0" A F F CL C I" 11111116 `%I%%;` :.Corrugated stainless steel hose with available in 2', stainless steel brae gnths FlexHead Sprinkler Drop r Multi -port Bracket Adjustable Hub ,LEXJ�j�q� INDUS i"IES l Ci 'f4ex head'ommercial Ceiling Unit T -Bar Ceiling installation Model #2024,2036,2048,2060,2072 111 RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS 111 TOP BEAM/ C—CLAMP WITH SET SCREW PIPE SWIVEL RING .11111 3/8' ALL THREAD ROD 0i STEEL JOIST/TRUSS HANGER DETAIL NTS ACC O Without Comments O As Notedn Red 15r Per The Attached Letter These plans have been reviewed by Tne Tukwila Fire Prevention Bureau for conformance v.,tri current Clty sta1Cards. Acceptance is slabiec* ro errors and omissions whle co rot autr=or'ze 0l03tirrts of adopted s � I''.a, ds aan`.l cit: nanzes Tne res ,uPS'!tisty cor the adequacy of des'g" rrsr-s totally w'rti trfe designer. Add (ions Ge'eaol,s r - (I'ylSicrS to rrese dir3 trgs after this crate v.l.l vad t . _-ep:ance a-,0 "r .i ra,,:, re a resiJo+rnit'.ai of r�vis C ' 1;1f+#'CJS fo- SJCseorent ac,pr''✓vat Final a�ceprance s .GJect to fleia test a,na lnspec:lo i L The Tukwiia F:: e :."i.onn 6u-cau. Date (/-19� By: ;UKWILA r r D ZP RT I .NT .eazv c;..'I 2-.:1:-'_:75-4407 and i'2,lS:1-NV J id exact. z7 F , n cr rczto atIon apprcv2!. r • �► R��� Pm/ UIR r John J Abel r 1 C�80-0591-C•� I RrWhl �r - . LL les aaaaaarraaaaaaaaa 17l1i aa�aaamaai • CROWN FIRE PROTECTION INCORPORATED P 0 BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Ben Bridge jewelers 81 Southcenter Mall Tukwila, WA 98188 DATE t -/ 7 • r I DRAWN a ate. I SCALE , { �/ I PAID AP? > ;i zii5 .3 y36, y SHEET \UM3ESHEET TITLE BRID R s FA -01 SYSTEM I\ EO vlATI O N FA -02 TYPICAL WRING A\D IvOUNTING DETAILS FA -03 SYSTEV CALC U LATI O \S AND SI\ OLE LINE DIAGRAM FA -0L FI ALAN SYSTEV PLA\ SHEET INDEX ( Without Comments ❑ As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revisit -6 urawings for subsequent approval. Final acceptance is subject to held test and inspection by The Tukwila Fire Prevention Bureau. Date: Lj , o -1$ By: 5-1 1 . KWILA FIRE DEPARTMENT 2C,_3-: 75-4 :-O7 and z'u thk; 3 irc Permit No. IB-FB a,f- ri!: s for shut- �_ �fm cr re.Yzrei±on ppprova1 WISE SCHEDULE A\D CO SUIT FILL CHAT SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END TE SH WEL ,_.JRS DDITI ON FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 2 4 3 2 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 3 FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S BOX CEILING �.{ FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DETECTOR FDBZ492-HR IN/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD END-OF-LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND J j • �I J BEN BRIDGE JEWELERS 81 /SPACE #740 1.• W42 .•. aa,�..crw macys I MUMS F REIM_ ez RED. I w ` I •rr .53:113144 w J WIRE DESIGNATION GENERAL NOTES SITE PLAN PAID O f� R 1 0 i 6=.f `.e p, S :: !JKW!I A. FIRS - Cc- V13c(e uy Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved o crco_ r` WZ O wC*r6 Woa.z $ O WJO _D w < z W �s op C.' v,w< 0 c! z _ <w Z CC w `LOi CO co CALE: NOT TO SCALL DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/02/18 BACKROUND PLAN PROVIDED BY: .OB NUMBER: 3172-1} SHEET V\ WIRE DESIGNATI❑N SYMBOL DESCRIPTION NUMBER DF CONDUCTORS SIZE TYPE COLOR CODE C D P S S' V V' I STROBE SYNC DATA LINE -ADDRESSABLE LOOP DEVICE POWER - 24VDC STROBE CIRCUIT - FEED STROBE CIRCUIT - RETURN SPEAKER CIRCUIT - FEED SPEAKER CIRCUIT - RETURN REMOTE INDICATION LIGHT TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) TWO #16 FPL/FPLR RED (JACKET) TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR W/ SHIELD #14 FPL/FPLR RED (JACKET) TWISTED PAIR #14 FPL/FPLR RED (JACKET) TWISTED PAIR #14 FPL/FPLR RED (JACKET) TWO #18 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/8" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END TE SH WEL ,_.JRS DDITI ON FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. 23. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY E 2 4 3 2 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT BPS REMOTE BOOSTER POWER SUPPLY (EXISTING) PAD -3 SIEMENS PAD-3-ENCL 66" A.F.F. TO TOP 3 FIRE ALARM HORN STROBE ZH-MC-CW SIEMENS 4S BOX CEILING �.{ FIRE ALARM STROBE ZR -MC -CW SIEMENS 4S BOX CEILING HT -R INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S BOX VERIFY IN FIELD DUCT SMOKE DETECTOR FDBZ492-HR IN/ HFP-11 DET. SIEMENS DUCT HOUSING VERIFY IN FIELD TSM DUCT DETECTOR TEST SWITCH TSM -1 SIEMENS 1 -GANG BOX VERIFY IN FIELD END-OF-LINE RESISTOR A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A E EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND J j • �I J BEN BRIDGE JEWELERS 81 /SPACE #740 1.• W42 .•. aa,�..crw macys I MUMS F REIM_ ez RED. I w ` I •rr .53:113144 w J WIRE DESIGNATION GENERAL NOTES SITE PLAN PAID O f� R 1 0 i 6=.f `.e p, S :: !JKW!I A. FIRS - Cc- V13c(e uy Proprietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved o crco_ r` WZ O wC*r6 Woa.z $ O WJO _D w < z W �s op C.' v,w< 0 c! z _ <w Z CC w `LOi CO co CALE: NOT TO SCALL DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/02/18 BACKROUND PLAN PROVIDED BY: .OB NUMBER: 3172-1} SHEET V\ THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NEPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. DUCK OVER 3' WIDE: SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 120VAC-60HZ DEDICATED O.1ERGENCY TUBE OUTLET--. SAMPLING TUBE INLET—. SAMPLING AT LEAST SIX DUCT WIDTHS FROM BEND DUCT DETECTOR MOUNTING DETAIL NOTE FCR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. *CONTACT RATINGS: 4.0A 0 125VAC 4.0A 0 30VDC ISrATE FFRRL[1MSGRUUNND1GD TO NEXT ADDRESSABLE (-I- DEVICE +DEVICE STOP IF LAST DEVICE raw XLS CONTROL PANEL (+ DR PREVIOUS ADDRESSABLE DEVICE — O° L�1 � r cR0l1 &I L 4 J 0 HTRI-R 0 Je 06 0 NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. C—CABLE C—CABLE GRD N L ©Qco PAD -3 00 INPUT INPUT TROUBLE NACI NAC2 NAC3 NAC4 AUX +1— 1 2+2— 2 NC C NO + — + — + — + — + — 0 (-) (+) 2 NAC 4 CIRCUIT NAC 3 CIRCUIT NAC 2 CIRCUIT (-) CEILIN TILE SUPPORT BRIDGE 4L SQUARE DEEP BOX CEILING /— HORN STROBE STROBE ONLY DROP CEILING MOUNTING HARD LID CEILING SUPPORT BRIDGE 4° SQUARE DEEP BOX CEILING HORN STROBE STROBE ONLY HARD LID MOUNTING HORN STROBE & STROBE CEILING MOUNTING DETAIL EXISTING POWER SUPPLY & RELAY MODULE WIRING DETAIL COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE 0 (+) FROM XLS CONTROL PANEL OR E`+ PREVIOUS ADDRESSABLE DEVIL END OF LINE DEVICE(3.6K 1/4W) SUPERVISED SWITCH _L oeT GROUND 0 0 0 0 HTRI-R OSTATUS LED Co 0 N.O. 0 CD 0 N.C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 MUSIC HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY HORN/STROBE OR STROBE ONLY TYPICAL HORNSTROBES & STROBES ONLY WIRING DETAIL LAC POWER SOURCE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING RELAY CONTACTS (4.0A @ 125VAC) (4.0A @ 30VDC) HTRI-R RELAY MODULE BACKGROUND MUSIC SHUTDOWN WIRING DETAIL NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER TIN TEMPERA RE: +32' F 0' C TO 100' F 36 C) HUMIDITY: —9 % RELATIVE HUMIDITY, NON—CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) >— Sl DATA IN (+) > TO NEXT DEVICE OR END OF LINE DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT/MIN WHEN USED IN CONJUNCTION 11TH DUCT HOUSINGS AD -11P OR AD-11XPR DB -11 STANDARD r SMOKE DETECTOR BASE REAR VIEW (-) (+) SMOKE DETECTOR WIRING DETAIL > TO NEXT ADDRESSABLE DEVICE TYPICAL WIRING AND MOUNTING DETAILS FROM PREVIOUS ADDRESSABLE DEVICE TB1 C 90 1) NO COM NC EOLR 470 SWITCH INPUT 19 0 + - LED TSM -1 0 00 TO FAN SHUTDOWN TO NEXT e ADDRESSABLE DEVICE ° 0 .I1 -6) 2 00 HTRI-R 0 NO COM 6) NC ® • TYPICAL DUCT DETECTOR/HTRI-R MODULE/TSM-1 SWITCH WIRING DETAIL JUNCTI❑N BOX—, MOUNTED ON \� CEILING FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT O O TO NEXT DEVICE --CADDY BAR 0 0 I SMOKE DETECTOR -- SUSPENDED ILLUMINATED CEILING SMOKE DETECTOR MOUNTING DETAIL Proprietary and Confidential, Co I -r) co AVE. SO., SEATTLE, VVASHINGTON cv 0 c\I I I J RELEASE/REVISIONS REV. BY: I 0 m 0 DESCRIPTION SHOP DRAWINGS DATE 04/02/18 2 aaK ‹ v,�of} _J'4:7( I�— L�I00Cs �C SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/02/ 18 BACKROUND PLAN PROVIDED BY: .JOB NUMBER:31725-1} SHEET F' --O2 yy ht 2013 by Guardian Security Systems, Inc. All Rights Reserved —� A B C D E F G H J K FIRE ALARM BOOSTER Project: BEN BRIDGE JEWELERS Panel: EXISTING PAD -3 REMOTE Date: April 2, 2018 Module/Device POWER T.I. BOOSTER Qty SUPPLY POWER Standby (mA) BATTERY SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 15 15 0 140 140 0 TOTAL FIRE ALARM POWER SUPPLY 15 140 Auxiliary Device Current 0 0 Notification Appliance Load (Max. Total / mA) 0 2470 Total(A)= 15 Total(B)= 2610 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 15 2610 Total current ratings concerted to amperes (line D x .001) 0.015 2.61 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 0 Multiply lines E and F Total Standby AH 0.36 0.0023 Alarm sounding period in hours (5 mins+ .0833 hours) ««< 0.0833 Multiply lines E and H Total Alarm AH 0.0635 0.217413 Add lines G and I Total Standby and Alarm AH 0.577413 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 0.6928956 0.009600 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: BEN BRIDGE JEWELERS T.I. Panel: EXISTING PAD -3 REMOTE BOOSTER POWER SUPPLY Wire Resistance 2.58 Date: April 2, 2018 CURRENT TOTAL= 2470.00 ZH-MC-CW @l5cd 87 ZH-MC-CW @30cd 131 ZH-MC-CW @75cd 222 ZH-MC-CW @95cd 292 ZR -MC -W @15cd 64 ZR -MC -CW @l5cd 69 DEVICES MAXIMUM LOAD TOTAL mA=' Total Wire Resistance (R ) Total Device Load, Amps (1) : Voltage Drop ( E ) EOL Voltage 0 0 0 0 0 0 1500 14 24.00 1500 (WL*2)*(R/ft) 0.00 (Total Cct Load) 1.50 (E=I*R) 0.00 24 - E) 24.00 ZH-MC-CW @l5cd ZH-MC-CW @30cd 1 ZH-MC-CW @75cd 1 ZH-MC-CW @95cd 3 ZR -MC -W @15cd 1 ZR -MC -CW @95cd DEVICES 6 87. 131 222 222 2.92 292 64 192 264 264 TOTAL m A= 970 14 267 0 Total Wire Resistance (R ) Total Device Load, Amps (1) Voltage Drop ( E ) EOL Voltage 22.66 970 (WL*2)*(Rift) (Total Cct Load) (E_I*R) 24 - E) 1.38 0.97 1.34 22.66 CALCULATIONS BEN BRIDGE JE , E ERST.1: FACP: ADD-QiS DESCRIPTION SHOP DRAWINGS Current Load: Standby: Alarm: co N Device Type Qty Amps Total Amps Total NFP -11 0 0.0022 0.0022 0.0023 0.000 ««< FDBZ492-HR 2 0.0635 0.0635 0.064 0.128 HTRI MODULE 3 0.009600 0.0096 0.021 0.063 0.0731 Amps 0.191 Amps S S2-1 S2-2 S2-3 S2-4 S2-5 S2-6 15Cd 75Cd 15Cd 15Cd 95Cd 95Cd D,I 21 SINGLE LINE DIAGRAM D,I IHT-R1 21 TSM EOL S3 Pro FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. t J V) O� 013 N '0 .0 N AVE. SO., SEATTLE, WASHINGTON r- o (_) (v rr) RELEASE/REVISIONS m uJ DMG DESCRIPTION SHOP DRAWINGS DATE co N 0 Nt 0 ««< CC 0 uJ cie) W co W _ jpr LLJ 5.O v°') O W2 J0 w <z ctd LLI LU EE 110 CO 00 0 LLf CO SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/02/1 8 BACKROUND PLAN PROVIDED BY: .0B NUMBER:31725-1 SHEET FA -03 rietary and Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved 8'-5 1/2" 6'-1" 13-9 1/2" 7 FLOOR STRIKES SPACED @ 8'-5 1/2=50-10 1/8" 11 1/2" 3 3/4" S2-3 15Cd RESTROOM!' 106 71- PTDNVR CN 1 HT—R1 rc L— • STOCK ' 105 S2-2 75Cd t I 1: 5'-0" 10 IT CLOSE 104 D / CN 1-5" - 1-6 2 3/8" 1-' 1--t' •'•• . SALES b' FLOOR 4 102 t -6" REF DISH P3 HT—R T 7,-0!, BRIJ:WT.7r, AREA' 41-7" 107 S2-1 15Gd TO EXISTING TENANT JUNCTION BOX r 8'-9 3/4" t. r 7'-0" 19'-0" ri) to \ 4"MAX 5 FLOOR STRIKES SPACED @ 8'-6 5/8"=34'-2 1/2" ROLEX 103 +/-4'-5"V1F EQ j, EQ 10 4'-5 1/2" 8-10 1/4" 6'-11 3/4" 6-4 7/16" 6'-3 5/16" 6'-4 7/16" 60-1 1/2" 24'-0" 24'-0" 7'-10" f 10 FIRE ALARM SYSTEM PLAN FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACKGROUND MUSIC INTERFACE. DUCT DETECTOR, RELAY MODULE FOR FAN SHUTDOWN & TEST SWITCH LOCATIONS TO BE FIELD VERIFIED BY MECHANICAL, ELECTRICAL AND FIRE ALARM CONTRACTORS. 4,101, 400.0t0 11; tr, 41 116,, RELEASE/REVISIONS IREV. BY: I . m 0 DESCRIPTION SHOP DRAWINGS LL, E- < 04/02/18 2 <<<<< (S-CALE: 1 / 4" = 1 '0" DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE: 04/02/1 8 BACKROUND PLAN PROVIDED BY: .1_0Ei NUMBER: 31 725— 1} r SHEET FA -04 Proprietary and Confidential, CouLght 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET I\ FILE CO UVIHESHEET TITLE SHEET INDEX BEN BRIDGE FIRE ALARM SYS EM TUKWILA, WASHINGTN FA -01 SYSTEM I\FOMATION FA -02 TYPICAL DETAILS - WRING AND MOUNTING FA -03 FRE ALARM SYSTEM FLOO PLAN FA -04 SYSTEM CALCULATIONS (GENEAL), SITE PLAN n A EPTE Without Comments As Noted In Red Per The Attached Letter nese plans have been reviewed by The Tukwila Fire Prevention Bureau for confol roar,oc with current city standards. Acceptance . _ .,. a to ellcrs and omissions which do not _:st,tiloriL vi _,I;:tions of adopted star,aara, _crd oKlIn: zcc3 TI':., ;:. cr i iy for the adegil '� o ..,: i::)n tr,:it ii I. r :. ta"signer. Additions, i.:i,'i:: i:: C)! i'i:'v ^; i. ^ - ;l i+_ :': draawings atter this da: :i. v ;.h accepi_Yr,r:_ ,.-d r:al require a resubmittal of revised arawings to subsequent approval. Final accepi:ance is subject to field test and inspection b\ The Tukwila Fire Prevention Bureau. G3 Date: / - kr- Og By: 3/ I UKWILA FIRE DEPART:a I Please call: 575-4407 and give this job No. GE- F - and exact address for shut, awn or restoration approval vmmacr .,-Morsvwamer' M NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATI❑N LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED 1418 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END GENERAL NOTES FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED SYMBOLS LEGEND QUANTITY 2 1 6 1 EX SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM EX CONTROL PANEL XLS-V SIEMENS PROVIDED 66" A.F.F. TO TOP FARA FIRE ALARM REMOTE ANNUNCIATOR SDD-C SIEMENS PROVIDED 66" A.F.F. TO TOP BPS REMOTE BOOSTER EX POWER SUPPLY PAD -3 SIEMENS PROVIDED 66" A.F.F. TO TOP INTERFACE MODULE HTRI-R WITH RELAY SIEMENS 4S DEEP VERIFY IN FIELD 0 DUAL INPUT INTERFACE MODULE HTRI-D SIEMENS 4S DEEP VERIFY IN FIELD HCP CONTROL POINT MODULE HCP SIEMENS 4S DEEP VERIFY IN FIELD HZM REMOTE CONVENTIONAL HZM ZONE MODULE SIEMENS 4S DEEP VERIFY IN FIELD ISN LINEAR BEAM SMOKE DETECTOR PBA -1191 SIEMENS PROVIDED VERIFY IN FIELD SMOKE DETECTOR HFP-11 W/ SIEMENS (ADDRESSABLE -PHOTO) DB -11 BASE 4S DEEP W/ 1G RING CEILING ® DUCT SMOKE p DETECTOR AD2-P W/ SIEMENS TSM MODULE DUCT HOUSING VERIFY IN FIELD HEAT DETECTOR (ADDRESSABLE) HFPT-11 W/ SIEMENS DB -11 BASE 4S DEEP W/ 1G RING CEILING LJC FIRE ALARM SPEAKER STROBE (CEILING MOUNT) ZH-MC---CW SIEMENS 4S DEEP BOX CEILING c FIRE ALARM SPEAKER STROBE (WALL MOUNT) FIRE ALARM STROBE (CEILING MOUNT) ZH-MC-W SIEMENS 4S DEEP BOX 80" A.F.F. TO BOTTOM ZR -MC -CW SIEMENS 4S BOX W/ 1G RING CEILING L FIRE ALARM STROBE (WALL MOUNT) ZR -MC -W SIEMENS 4S BOX W/ 1G RING 80" A.F.F. TO BOTTOM U.0.N. pc FIRE ALARM SPEAKER (CEILING MOUNT) SET -CW SIEMENS 4S DEEP BOX CEILING W/ 1-1/2" EXT. B WP FIRE ALARM SPEAKER (WALL MOUNT) FIRE ALARM STROBE (WEATHERPROOF) SET -W SIEMENS 4S DEEP BOX w/ 1 -1 /2" EXT. 80" A.F.F. TO BOTTOM SET -S17 -WP SIEMENS MT -SUR -BOX VERIFY 1/2" PIPE IN FIELD MR MULTI -VOLTAGE CONTROL RELAY MR -201 /C AIR PRODUCTS 4S BOX VERIFY IN FIELD MAGNETIC DOOR HOLDER F.B.O. F.B.O. F.B.O. VERIFY IN FIELD FA JB❑X FIRE ALARM TERMINAL CABINET F.B.O. F.B.O. F.B.O. VERIFY IN FIELD O JUNCTI❑N BOX F.B.D. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.❑, FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.D.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A PAID SEP - a 2008 Tukwila Fire Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NYI DESCRIPTION SHOP DRAWINGS DATE 03 0 0 03 2 CCCaC -% l/ Z cc 0 0 z c0 CO J 00) LII W 0 W~ C z Cr 2w. m �=a Z < =� CO 1- W (1) SCALE: 1/8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 8/01/08 BACKROUND PLAN PROVIDED BY: \OB NUMBER: SHEET FA -01 , THE DUCT SMOKE DETECTOR ASSEMBLY SHOULD BE INSTALLED IN ACCORDANCE WITH NFPA 72. THE PREFERRED INSTALL LOCATION OF THE HOUSING IS IN A LENGTH OF STRAIGHT DUCT AT LEAST SIX DUCT WIDTHS FROM ANY BEND OR OTHER OBSTRUCTIONS AS INDICATED. BEND OR OTHER OBSTRUCTION ANY DUCK OVER 3' WIDE, SAMPLE TUBE MUST GO THRU THE DUCT AND BE CAPPED. 6-10 DUCT EQUIVALENT DIAMETERS TYPICAL SMOKE DETECTOR ISTALATION REQUIREMENT LABEL SCALE COMBINE ALL SHIELDS AND IS❑LATE FROM GROUNDING TO NEXT ADDRESSABLE DEVICE STOP IF LAST DEVICE FROM XLS CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVIC 0 DUCT DETECTOR LOCATI❑N 1 � END OF LINE DEVICE(3.6K 1/4W) .T e SUPERVISED SWITCH GROUND r-) -4- 0 HTRI—R OSTATUS LED 00 0 N.0 0 COM c0 0 N,C. NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. TYPICAL HTRI-R CONTROL RELAY MODULE -WIRING AND MOUNTING DETAIL 0 LABEL SSE (BACKGOUND MUSIC SHUTDOWN) PREVI❑US ADDRESSABLE[ DEVICE TO NEXT ADDRESSABLE DEVICE + NOTE 11 VOLTAGE MAX. - CURRENT MAX. - CONT. RES, MAX, - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - OUTLET SAMPLING--\\ TUBE INLET SAMPLING--•\ TUBE AT LEAST SIX DUCT WIDTHS FROM BEND TYPICAL MOUNTING FOR AD2-P DUCT DETECTOR SCALE:NONE COMBINE ALL SHIELDS AND ISOLATE FROM GROUNDING 0 TO NEXT ADDRESSABLE DEVICE f STOP IF LAST DEVICE 1(-) FROM XLS CONTROL PANEL OR PREVI❑US ADDRESSABLE DEVICE (-) RELAY CONTACTS (4,0A @ 125VAC) (4,OA @ 30VDC) 27 VDC 3,5 nA DURING POLLING 10 OHMS 200 FT, (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD CLOSED AND/OR OPEN FOR AT LEAST .25 SEC. TO GUARANTEE DETECTI❑N. 0 + 100I TB1 SSmoo0 123456 HCP TB2 0 0 +- 654321 END OF LINE 1 DEVICE 7 (3.6K 1/4W) SUPERVISED SWITCH % GROUND -0 0 0 tip HTRI—D OSTATUS LED CO 0 NOT USED 0 NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. 0 TYPICAL HTRI-D ADDRESSABLE INPUT MODULE -WIRING DETAIL LABEL SCALE (FIRE SUPPRESSION SYSTEM INTERFACE) 0 GND N AC 0 PAD -3 0 0 00 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1+ 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 Lel 61_Q. 0 24K n + TYPICAL WIRING FOR HCP MODULE (PAD -3 TRIP) LABEL SCALE END OF LINE DEVICE 3.6K 1/4W) \SUPERVISED SWITCH NAC -4 NAC -3 Z NAC -2 NAC -1 FRONT VIEW / I NOTE: FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. NOT USED REMOTE DEVICE LOOP NOT USED REMOTE DEVICE LOOP .L 0. 0 FROM XLS CONTROL PANEL OR (+)> PREVIOUS ADDRESSABLE DEVICE (-)> 470 OHMS 4W EOL TS M-1 0 • -1-2345 TYPICAL AD2-P DUCT SMOKE DETECTOR - WIRING DETAIL SCA1E NONE 0 0 EARTH GROUND -3.4+)TO NEXT DEVICE OR >t-) STOP IF LAST DEVICE HORN STROBE / STROBE WIRING DIAGRAM LABEL SCALE SPEAKER STROBE OR STROBE ONLY R 1 0 HORN/STROBE 4S DEEP BOX IN/ 1-1/2" EXTENSION RING (SPEAKER STROBE) 4S BOX (STROBE ONLY) WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE EEL NOTE FOR ADDITIONAL SPECIFICATIONS SEE PRODUCT DOCUMENTATION. OPER 11N TEMPERATU +32'F 0'C TO 100F (3E: 311C) HUMIDITY: 9 % RELATIVE HUMIDITY, NON -CONDENSING HFP-11 SMOKE DETECTOR FROM PREVIOUS ADDRESSABLE DEVICE OR POWER SOURCE DATA IN ( ) > - DATA IN (+) > DEVICE IS LISTED FOR AIR VOLOCITY APPLICATIONS OF 300-4000 FT IN WHEN USED IN CONJUNCTION WIN DUCT HOUSINGS AD -11P OR AD-11XPR r— D8-11 ' STANDARD SMOKE DETECTOR BASE REAR VIEW HFP-11 SMOKE AND DB -11 DETECTOR BASE -WIRING DETAIL LABEL SCALE > ( ) DATA OUT (+) DATA OUT CEILING MOUNT SPEAKER/STROBE MOUNTING (HARD LID) HARD LID -\ CEILING SPEAKER SUPPORT TILE BRIDGE HARD LID -\ 4' SQUARE DEEP BOX WITH 1-1/2' EXTENSION CEILING MOUNTED SPEAKER/STROBE CEILING MOUNTED SPEAKERISTROBE MOUNTING (DROP CEILING) SCALElONE JUNCTI❑N BOX—, MOUNTED ON \ CEILINGI FLEX JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT / / / / // 0 0 0 0 f 1 TO NEXT DEVICE CADDY BAR SMOKE DETECTOR SMOKE DETECTOR MOUNTING SCALE:NONE SUSPENDED ILLUMINATED CEILING DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS 1 CALE: 1 /8"= 1 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 8/01 /08 BACKROUND PLAN PROVIDED BY: ,0B NUMBER: SHEET FA -02 75 o— 2S 75 y o-- 2S q 2S 2S FA -BOX 2 w� 75 a— 2S IJ c -75 15 o— 2S y 75 C o— 2S EOL—S1 NORTH BEN BRIDGE \NESTFIELD SOUTHCENTER MALL SCALE 1l8" -V FLAG NOTES: FIELD LOCATE RELAY MODULE FOR BACK GROUND MUSIC INTERFACE. FIELD LOCATE SIEMENS DUCT DETECTOR ON RETURN SIDE OF ALL VAV UNITSXSEE SIEMENS INSTALLATION SUBMITTAL FOR LOCATION GUIDELINES AND FA -02) DEVICES SUPPLIED BY GSS, INSTALLED BY MECHANICAL CONTRACTOR. WIRED BY ELECTRICAL CONTRACTOR. SIEMENS HTRI—D ADDRESSABLE INPUT WITH HOOD VENILLAT❑R FIRE SUPPRESI❑N SYSTEM. FIELD LOCATE WITHIN 3 FEET OF CONTRL PANEL. FIELD LOCATE SIEMENS PAD -3 BOOSTER POWER SUPPLY FOR STROBE POWER, AC POWER BY EC FROM DEDICATED, LOCKED OUT 20A, 110 VAC BRANCH CIRCUIT. 1743 IST FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z Q DESCRIPTION SHOP DRAWINGS DATE 1 8/01/08 2 aaCCa J co co T JOf? W �� Q �r W 0 Lw - F CC MWCO oo 3 < Z ct � Lk � e:)s meg. °° ..CALE: 1 /8"=1 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 8/01 /08 BACKROUND PLAN PROVIDED BY: \0B NUMBER: C SHEET k FA -03 Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved I I I OR RO \ / (Th .•••• • • I i--- L. V 171, fl7! ' CANOPY ° 11 ffi ELEC ELEC PARFUMFRIE SUNCOAST TI ON PICTURE WA LD N IR 00k. S NORTH BIAGIO VERIZON T Li Li 02 < Lu PUB' IC CORR. [LEG I7 -1 -v -T CASUAL CORNER R. II< II I I—• 0 LJ WIRELESS SYSTEM CALCULATIONS •g, Z(I) 00 ch - 0 ELEC BATTERY SIZING CALCULATION MADE IN WASHINGTON SPENCER GIFTS BEN BRIDGE WESTFIELD SOUTHCENTER MALL N4ALL MALL OFFICE OFFICE TZ nL. SCALE NTS 2S 75 C 15 2S 2S 2S 2S 2S 30 C 75 C 75 C 75 C 75 EOL—S1 2S FA—BOX EX FACP 0 21 Notification Appliance Circuit Detail PROJECT: !WESTFIELD SOUTHCENTER MALL Panel: BEN BRIDGE Date: September 8, 2008 CIRCUIT: S1 QTY Device Type !Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 0 :ZH-MC @1 5CD 1 !ZH-IVIC @30CD 142 142 5 iZH-41.11C ©75CD 219 1095 i I 1 I i 1 I I Wire Resistance 1.62 CURRENT TOTAL= 1301 108 0! Total Wire Resistance ( R ) 0.65 ( WL * 2 )* (R/ft) Total Device Load, Amps (I) 1.301 (Total Cct Load) Voltage Drop ( E) 0 0 (E= I * R) 0 . _ 0 1 Z-MC@l5CD 64' 64 0 'Z-MC@30CD 98 0 DEVICES= 7 TOTAL mA=1 1301 EOL Voltage 19.55 (20.4 - E) 11 12 202 19.54852152 1301 1 FAX (206) 628-4.990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: BEN BRIDGE BEN BRIDGE FACP ADD ONS SIEMENS PAD -3 Signal Extender Panel Battery Load Calculations DESCRIPTION SHOP DRAWINGS DATE 8/01/08 2 <<<<IC Current Load: Standby: Alarm: Current Load: Standby: Alarm: Device Type Qty Amps Total Amps Total Device Type Qty Amps Total Amps Total HFP-11 0.0022 0.0022 0.0023 AD2-P 1 0.0635 0.0635 0.064 0.064 Main System Board 1 0.03 0.03 0.030 0.030 HTR -R HTRI-D ICP -B6 2 0.009600 0.0096 0.021 0.042 ZH-MC-CW@15CD ZH-MC-CW ©30CD 0.108 0.001600 0.0035 1 0.142 0.142 0.005 ZH-MC-CW ©75CD 5 0.219 1.095 ZR -MC @15CD 0.0731 Amps 0.106 Amps 0.445 1 0.064 0.064 Standby Current Load: 0.0731 Amps For 24 Hours = 1.754 Amp -hours ZR -MC @30CD 0.098 Alarm Current Load: 0.106 Amps For 5 Minutes= 0.009 Amp -hours 0.03 Amps 1.331 Amps 25% Derating= 2.204 Amp -hours Standby Current Load: 0.03 Amps For 24 Hours = 0.720 Amp -hours Alarm Current Load: 1.331 Amps For 5 Minutes= 0.112 Amp -hours Total System Current Load: 2.204 Amp -hours 25% Derating= 1.040 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH Total System Current Load: 1.040 Amp -hours Battery Pair to be Used: 12VDC Amp -hours 7AH BATTERY SIZING CALCULATION MADE IN WASHINGTON SPENCER GIFTS BEN BRIDGE WESTFIELD SOUTHCENTER MALL N4ALL MALL OFFICE OFFICE TZ nL. SCALE NTS 2S 75 C 15 2S 2S 2S 2S 2S 30 C 75 C 75 C 75 C 75 EOL—S1 2S FA—BOX EX FACP 0 21 Notification Appliance Circuit Detail PROJECT: !WESTFIELD SOUTHCENTER MALL Panel: BEN BRIDGE Date: September 8, 2008 CIRCUIT: S1 QTY Device Type !Alarm Current Alarm Total Wire Size Wire Length Voltage at EOL Circuit Total 0 :ZH-MC @1 5CD 1 !ZH-IVIC @30CD 142 142 5 iZH-41.11C ©75CD 219 1095 i I 1 I i 1 I I Wire Resistance 1.62 CURRENT TOTAL= 1301 108 0! Total Wire Resistance ( R ) 0.65 ( WL * 2 )* (R/ft) Total Device Load, Amps (I) 1.301 (Total Cct Load) Voltage Drop ( E) 0 0 (E= I * R) 0 . _ 0 1 Z-MC@l5CD 64' 64 0 'Z-MC@30CD 98 0 DEVICES= 7 TOTAL mA=1 1301 EOL Voltage 19.55 (20.4 - E) 11 12 202 19.54852152 1301 1 FAX (206) 628-4.990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: NVI DESCRIPTION SHOP DRAWINGS DATE 8/01/08 2 <<<<IC LU LU coQ 03 w <z < 0 0 CC LLI '-iZ Z CC 2 6= w co cd -cc ow 0 _3 I< Z < LLI LU 15 CO u.-fc- cl) 0 c73.0 (f) 'CALE: 1 /8" = 1 DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE: 8/01 /08 BACKROUND PLAN PROVIDED BY: RISER DIAGRAM VOLTAGE DROP CALCULATION Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved ,JOB NUMBER: SHEET \_ FA -04_ 1 GENERAL NOTES: ESTERN STATES AREA OF WORK 1. Western States Fire Protection to relocate pendent sprinklers due to new walls and ceilings added for tenant improvement. 2. Sprinklers shall be spaced in accordance with NFPA #13 Ordinary Group II Occupancy with 15'-0" maximum distance between sprinklers and a maximum coverage of 130sq. ft. 3. The building qualifies as non obstructed construction. 4. All hanger assemblies shall be spaced and installed in accordance with NFPA and manufacturer's specifications. 5. Branchline and arm over is black Schedule 40 pipe. 6. Ali new=threaded fittings to be ductile iron. 7. The owner is responsible for all appropriate maintenance of sprinkler system in accordance with NFPA, as well as state & local codes. 8. The owner is responsible for the freeze protection of all sprinkler system piping and components that are not designed for freezing conditions. 9. Existing fire sprinkler system to remain. Western States Fire Protection will modify the existing system only in areas of work. All other areas are not in contract and WSFP in not responsible for existing conditions. PIPE LEG_ENC EXISTING PIPE NEW PIPE SYMBOL LEGEND VICINITY MAP NOT TO SCALE REVISIONS I�OKM SPRINKLER LEGEND • • 1 ,N m -WO RKROON 1u1� 11111111 111S® •. o R Atir ii♦L�� flu, C i a 11 ri 1 ' 1 1•0 1'1-quernir- Nommi.v. Rue il O O R O Ro 0 11) O altaRK,RO R R 9••-A / 0 0 0 4 - 9'47 N 41.11Nt \ Ns\ kla \i NEW NEW ADDED RETAIL SECTION SALES AREA N7411.7 Ro E4 O 9'4; 12' O 9•-P VP' 9' -CI' E RIDGEJEWE RS SCALE: 1/4" = 1'-0 4' 2' 0 2' 4' 8' SPRINKLER LEGEND APPROVAL: CITY OF TUKWILA 2 -WAY EARTHQUAKE BRACE NO. DESCRIPTION DATE SYMBOL DESCRIPTION ORIF. FINISH OUANTRY SYMBOL DESCRIPTION ORF. TEMP FINISH QUANTITY 4 -WAY EARTHQUAKE BRACE EXISTING SSP 1/2" 5.6 155° CHROME 26 CONT. NO.: N/A HYDRAULIC REFERENCE POINT R RELOCATE TO REL G4A CONCEALED 1/2" 5.6 165° WHITE 13 DRAWN BY: C. Isaac HANGER SYMBOL OR OP RELOCATE EXISTING SSP 112" 5.6 155° CHROME 7 SPRK. ON SHEET: 50 PLUG EXISTING SSP 1/2" 5.6 155° CHROME SPRK. ON JOB: 24 DATE: 08/06/08 HANGER DETAIL NOT TO SCALE Hanger No. 07C HILTI Kwik Bolt II. / ` , , A- / / .,.y Rod Coupling —` Concrete Construction d Cut Rod Lgth All Thread — Rod CL Bottom of Concrete to -`s Rounded to NearestY2' Rounded to 3/8" All Thread – Rod ~q. 1111111 Center Line of Pipe Nearest Inch Swivel Ring �, ,._A Pipe Note on Plan Center Line of Pipe Note on Plan: Hanger Number Swivel Ring and 'A' Dimension HANGER DETAIL NOT TO SCALE FILE COPY HANGER DETAIL NOT TO SCALE TYPICAL FLEXABLE SPRINKLER CONNECTION: u PIPE NIPPLE w w. • SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID CEILING TILE Western States Fire Protection Company 7102180th AVE NE, STE A-105 - REDMOND, WA- 98052 Lie. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE IAUSTIN I DALLAS/ DECATUR / DENVER !DULUTH /HOUSTON ! KANSAS CITY LAS VEGAS/MINNEAPOLIS / PHOENIX ! PORTLAND /RAPID CITY/ ST. PAUL/SALT LAKE CITY/SEATTLE Phone:425-881-0100 Fax:425-881-3030 SPRINKLER HEAD FLEXHEAD DETAIL NOT TO SCALE BEN BRIDGE JEWELERS UNIT #740 -2477 SOUTH CENTER PKWY TUKWILA, WASHINGTON pA (j[ -7 2008 CONTRACTOR I Tukwila Fire te-5' 477/ a Hanger No. 05C Concrete Anchor HILTI 3/8" HDI -P L. k/ / 5/ Hilti 3/8" HDI -P / / \,:" (Dri led) /� ` / % / -`s Rounded to NearestY2' 3/4" 3/8" All Thread – Rod ~q. 1111111 j Concrete Construction Bottom of Concrete to Center Line of Pipe Swivel Ring Pipe Note on Plan: Hanger Number and 'A' Dimension FILE COPY HANGER DETAIL NOT TO SCALE TYPICAL FLEXABLE SPRINKLER CONNECTION: u PIPE NIPPLE w w. • SPRINKLER BRANCHLINE FLEXABLE CONNECTING HOSE IN STANDARD LENGTHS REDUCING FITTING SUSPENDED T -BAR GRID CEILING TILE Western States Fire Protection Company 7102180th AVE NE, STE A-105 - REDMOND, WA- 98052 Lie. #: WESTESF136QF WESTERN STATES FIRE PROTECTION COMPANY- OFFICES LOCATED ALBUQUERQUE IAUSTIN I DALLAS/ DECATUR / DENVER !DULUTH /HOUSTON ! KANSAS CITY LAS VEGAS/MINNEAPOLIS / PHOENIX ! PORTLAND /RAPID CITY/ ST. PAUL/SALT LAKE CITY/SEATTLE Phone:425-881-0100 Fax:425-881-3030 SPRINKLER HEAD FLEXHEAD DETAIL NOT TO SCALE BEN BRIDGE JEWELERS UNIT #740 -2477 SOUTH CENTER PKWY TUKWILA, WASHINGTON pA (j[ -7 2008 CONTRACTOR I Tukwila Fire te-5' 477/ a