HomeMy WebLinkAboutPP - 2800 SOUTHCENTER MALL K-0738 - UNKNOWN TENANT - PERMITS AND PLANS2800 SOUTHCENTER MALL K-0738 KIOSK ASSOCIATED PERMITS 09-S-199 Without Comments Q As Noted in Red Q Per The Attached Letter These plans have been reviewed by The Tukwila Fire ''revention Bureau for conformance with current City standards: Acceptance is subject toerrors and omissions which do not authorize violations of adopted <,andards and ordinances. The responsibility for the adequacy of design rests totally with the designer, Additions, deletions or revisions to these drawings after this date wilt void this acceptance and +!till require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to ilelti ie3siw and Inspection by The Tukwila Fire Prevention bureau. Date: /?_ 4 05 By: ftaUKWIIA FIRE D&Mt I'oacmt. Please call: 5754407 and give this job NO. Dq- \C- /gel .` and exact address for shut. '\ *win or re rattan �I�prov l: t CO NOTICE Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrostatic test approval. F 0 SOLID SURFACE COUNTER. TOP AND EDGE BAND, 55-2 CLEAR SNEEZE GUARD SOLID SURFACE FACE, 55•-2 —SURFACE MOUNTED COPPER LETTERING —FLUSH MOUNT EN SOLID SURFACE SOLID PARTIAL HEIGHT SURFACE TOE DOOR, 55-1 KICK, 55-1 NORTH ELEVATION SCALE: I/4"=1'-0" GLASS TILE, GT -I WOOD VENEER PLYWOOD, WD -I GRAPHIC ART BEHIND GLASS, GL -I TORAG Lit U (.n Lel UNICONEO CREPES ESCALATOR UP TO L2 T CLEARWIRE El SI DUKES CHOWDER HOUSE MAIN ENTRANCE Design per NFPA 13 — Ordinary Hazard Occupancy — 130 sq ft per sprinkler All materials to be new, U.L. listed, and F.M. approved All heads to be a minimum of 6' apart and to be unobstructed by any means • 1— Add Tyco Model TY -FRB TY 3231 155° Chrome Pendent Sprinkler Heads 1/2 x 1/2 1 — Total H 5C 5F 3F ALL UTILITIES MUST BE BROUGHT FROM UNDER THE '2"= FLOOR AND NOT THROUGH THE ESALATOR WALL. I5'-0" 5C (F03) N. Irr FLOOR PLAN SCALE: I/4'=1'-0" C FI3 T 2-5" T 2-8" 3A iJipni�unyni� ("n�w�ym Y V NORTH 1' 4' 0' 2' SCALE 1/4" = 1'-0" 8' D E FP-Oi QT—AS.,. "Automatic" Sprinkler Corporation of America • 401 A uabie in�JX. — ri • • C1; HANGERS No. 12 Concrete Hangers ■ Hanger Rings / Anchors: UL Listed & FM Approved ■ Hanger Rods: Comply with N FPA 13 ❑ All Thread Rods 0 Machine Thread Rods ■ Finishes: ❑ Standard Components 0 All Galvanized Components C 2.27 1"= 25.4 mm Components 1. Drop-in Anchor 2. Spring Clip Ceiling Plate (optional) 3. Hanger Rod 4. Adjustable Hanger Ring Application / Description No. 12 Hangers are designed to support piping under smooth or flat concrete slab construction. They utilize an anchor that is set flush in a hole predrilled in the concrete, then expanded against the sides of the hole with an internal plug. NFPA 13 terms this type of fastener an "expansion shield". In "Automatic's" data, however, the manufac- turer's nomenclature is used. It is called a drop-in anchor. There are 3 components in a basic No. 12 Hanger: The drop-in anchor, a threaded rod and an adjustable hanger ring. The rod may be either all thread rod (ATR) or ma- chine thread rod (MTR). All thread rod is considered to be standard, however. As a rule, machine thread rod is pro- vided only when it is a specific requirement of the job specifications. As an option, the hanger may be furnished with a spring clip ceiling plate when a more finished -appearance is needed in an area. NFPA Requirements / Limitations NFPA 13 has specific requirements and/or limitations 1/22 for the use of expansion shields (drop-in anchors) when they are installed in the vertical position. The standard reads: . . In concrete having gravel or crushed stone aggregate, expansion shields may be used in the vertical position to support pipe 4" or less in dia- meter. For the support of pipes 5" and larger, expansion Shields if used in the vertical position shall a/ternate with hangers connected directly to the structural members such as trusses and girders, or. to. the sides of concrete beams. In the absence .of convenient structural members, pipes 5" and larger may be sup- ported entirely by expansion shields in the vertical position, but spaced not more than 10 ft (3 m) apart. Expansion shields shall not be used in ceilings of gypsum or similar soft material. In cinder concrete, expansion shields shall not be used except on 'branch lines where they shall alternate with through bolts or hangers attached to beams. ri UNICONE CREPES KIOSK 2800 Southcenter Mall, Space + .K..0738 Tukwila, WA CROWN FIRE. PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 UNICONE CREPES KIOSK TUKWILA, WA PMD NOV 25 2009 Tuk\i lila Fire DATE: /it -2 9_0/ DRAWN: J )e SCALE: %m ).